FSS2020-0060ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE KAYLI ALFORD 2/22/2021 2/22/2021 INSPECTION REQUEST RECEIVED ON 2/22/21 FOR INSPECTION ON 3/1/21. PERMIT EXPIRES 2/23/21. PER KOHL OK TO EXTEND TO 3/2/21 TO ALLOW FOR INSPECTION. NO CHARGE FOR EXTENSION. REFUND ARMANDO MAGALLON 5/6/2020 5/6/2020 APPLICANT APPLIED FOR INCORRECT PERMIT TYPE (COMMERCIAL FIRE SPRINKLER). FEES HAVE BEEN UNPAID AND PAID USING THE CORRECT FEE TYPES, THE OVERPAYMENT AMOUNT OF $242.00 HAS BEEN PLACED IN THE CASHOVER DRAWER ACCOUNT. CASHOVER DRAWER OF $242.00 HAS BEEN REFUNDED BACK TO APPLICANT THORUGH AUTHORIZE.NET. ALL DOCUMENTS PERTAINING TO THE REFUND HAVE BEEN ATTACHED TO THIS PERMIT. CONDITIONS Description: SYMONS / BRES2019-0449 / FIRE SPRIKLERS Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - TRACT HOMES Status: FINALED Applied: 5/5/2020 ECON Parcel No: 764680020 Site Address: 81561 RONDA LA QUINTA,CA 92253 Approved: 5/19/2020 KHET Subdivision: TR 31681-3 Block: Lot: 103 Issued: 5/19/2020 KHET Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 3/1/2021 KHET Valuation: $2,500.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Friday, February 17, 2023 4:02:51 PM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0060 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT SYMONS FIRE PROTECTION INC 12155 PAINE PL POWAY CA 92064 (619)588-6364 angela@SymonsFP.co m CONTRACTOR SYMONS FIRE PROTECTION INC 12155 PAINE PL POWAY CA 92064 (619)588-6364 angela@SymonsFP.co m OWNER T D DESERT DEV 81570 CARBONERAS LA QUINTA CA 92253 (619)588-6364 FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY CASH OVER DRAWER 101-0000-42300 0 $242.00 $242.00 5/5/20 R61060 03796Q CREDIT SYMONS FIRE PROTECTION INC AMA Total Paid for CASH OVER DRAWER: $242.00 $242.00 FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $161.00 $161.00 5/5/20 R61060 03796Q CREDIT SYMONS FIRE PROTECTION INC AMA FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $242.00 $242.00 5/5/20 R61060 03796Q CREDIT SYMONS FIRE PROTECTION INC AMA Total Paid for FIRE FEES: $403.00 $403.00 FSS2020-0060, SYMONS FIRE PROTECTION, OVERPAYMENT 101-0000-42300 0 ($242.00)($242.00)5/6/20 R61061 CREDIT SYMONS FIRE PROTECTION INC AMA Total Paid for FSS2020-0060, SYMONS FIRE PROTECTION, OVERPAYMENT: ($242.00)($242.00) RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 5/5/20 R61060 03796Q CREDIT SYMONS FIRE PROTECTION INC AMA Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 5/5/20 R61060 03796Q CREDIT SYMONS FIRE PROTECTION INC AMA Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 Printed: Friday, February 17, 2023 4:02:51 PM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0060 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 5/6/2020 ARMANDO MAGALLON FSS2020-0060 REFUND FOR OVERPAYMENT FSS2020-0060.pdf 0 DOC 5/5/2020 EtrakitContractor APPLICATION FIRE APPLICATION SEPTEMBER 2019 FEE UPDATE (002) (Recovered).pdf 1 DOC 5/19/2020 KOHL HETRICK FSS2020-0060 - APPROVED PLANS and CALCS.pdf FSS2020-0060 - APPROVED PLANS and CALCS.pdf 1 BOND INFORMATION INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD HYRO KHET 8/27/2020 8/27/2020 APPROVED REMOTE VIDEO INSPECTION OVERHEAD ROUGH PIPING KHET 8/27/2020 8/27/2020 APPROVED REMOTE VIDEO INSPECTION JOB CARD UPDATED AND AS-BUILTS ADDED TO ATTACHMENTS FIRE FINAL**KHET 3/1/2021 3/1/2021 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) STEPHANIE SWANSTROM 5/5/2020 5/6/2020 5/5/2020 COMPLETE 1ST FIRE (2 WK)KOHL HETRICK 5/5/2020 5/19/2020 5/19/2020 APPROVED PARENT PROJECTS TOTALS:$418.00 $418.00 Printed: Friday, February 17, 2023 4:02:51 PM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0060 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 5/19/2020 KOHL HETRICK FSS2020-0060 - COA and JOB CARD.pdf FSS2020-0060 - COA and JOB CARD.pdf 1 DOC 8/27/2020 KOHL HETRICK FSS2020-0060 - APPROVED PLANS and CALCS (as-builts).pdf FSS2020-0060 - APPROVED PLANS and CALCS (as-builts).pdf 0 Printed: Friday, February 17, 2023 4:02:51 PM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0060 EL=15'6FAUW/HW/HWDWet Bar1" RISER IN WALL W/ INT. LABELED ACCESS PANELHEATZONEPIPING PLAN3/16"=1'-0"ALL 10'-1" FLAT CLG'SU.N.O.REPRESENTSLIGHT FIXTURESREPRESENTS LINEOF CLG CHANGEREPRESENTS SOFFITS. ALLSOFFITT TO BE 1'FTUP 5'FTUP 5'FTUP 3'FTUP 3'FTT.O.R.EL = 15'6B.O.R.EL = 9'53 CAR GARAGEFINISHEDUTILNO A.S.30 SQ.FT.VANLINARCHBED 2WICHALLBED 3WICVANNO A.S.36 SQ.FT.PATIODININGWICBATHNO A.S.55 SQ.FT.CLHALLWICARCH ARCH ARCH PORTICO12'1 CLGWICHALLBED 4HEATZONECASITAARCH ARCHARCHFPARCHARCH DN 3'FTARCHVANNO A.S.36 SQ.FT.M.BEDPATIOARCHARCHARCH ARCH ARCHPATIO HALLHALLARCHARCHARCH ARCHARCHARCH HEATZONEHEATZONEFPPANKITCHENGREAT RM14'1 CLGPATIOHEATZONEPATIOARCH ARCHFPFPFOYER14'1 CLG2WYFPNO A.S.15 SQ.FT.NO A.S.15 SQ.FT.DN 3'FTCABGREAT RMKITCHENM.BEDBBSECTION CUT B3/16"=1'-0"EL=15'7EL=15'8EL=15'9EL=15'10EL=15'11EL=15'12EL=20'13EL=20'14EL=20'15PLAN #25 - LOT 103ALL 1" CPVC PIPINGTHE RECIPIENT OF THESE PLANS HEREBY ACKNOWLEDGES THAT ALL PLANS, DETAILS, SPECIFICATIONS AND/OR METHODS OF INSTALLATION CONTAINED IN THIS SET OF DRAWINGS IS THE SOLE PROPERTY OF SYMONS FIRE PROTECTION, INC., AND THAT ANY USE OF THIS SET OF DRAWINGS IS PROHIBITED AND IS A VIOLATION OF COPYRIGHT LAWS WITHOUT FIRST RECEIVING PERMISSION FROM SYMONS FIRE PROTECTION, INC.DRAWN BY :SCALE :DATE :JOB NO.SHEET NO.PROJECT: CONTRACT WITH: DRAWING TITLE MARK DATE BYDESCRIPTION AUTHORITY HAVING JURISDICTION PHONE REVISIONS LA QUINTA FIRE DEPARTMENT (760) 777-7125 LA QUINTA, CA 92253 PLAN TYPE 25 ANDALUSIA - LOT 103 LA QUINTA, CA 92253 81-570 CARONERAS T.D. DESERT DEVELOPMENT FIRE SPRINKLER PLANS04-07-20AS NOTEDJOBANNY ECHEVERRIA19-0216FP2 OF FP2121 5 5 PA INE P L AC E * PO W AY, C A 9 2064 * (6 19) 588-6364 * FAX (619) 588-6805 * www.symonsfp.com * CA LIC. #682025 *111 03-20-20 JOBANNYBEAMS ADDED TO GREAT ROOM SYMONS FIRE PROTECTION, INC. 12155 PAINE PLACE POWAY,CA 92064 LICENSE C16-682025 HYDRAULIC CALCULATIONS FOR ANDALUSIA – PLAN TYPE 25 – LOT 103 REMOTE AREA 2 HEAD CALC RELIABLE RFC 43 CONC/FLAT FILE NUMBER: 19-0216 DATE: 04-08-20 -DESIGN DATA- OCCUPANCY CLASSIFICATION: R3 DENSITY: .05 gpm/225 sq. ft. AREA OF APPLICATION: 450 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 2 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 24.2 gpm TOTAL WATER REQUIRED (including hose): 29.2 gpm (5 gpm Hose STREAM) FLOW AND PRESSURE (@ NODE 5 BOR): 24.2 gpm @ 25.5 psi SPRINKLER K-FACTOR (ORIFICE SIZE): 4.3 DESIGN/LAYOUT BY: JOBANNY ECHEVERRIA AUTHORITY HAVING JURISDICTION: LA QUINTA FIRE DEPT. WATER FLOW AVAILABILITY DATA: STATIC: 93.5 psi RESIDUAL: 70.5 psi FLOW: 29.5 gpm WATER DEPARTMENT: COACHELLA VALLEY WATER 04-02-20 CALCULATIONS BY HASS COMPUTER PROGRAM HRS SYSTEMS, INC. ATLANTA, GA SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 4/9/2020 S:\JJ\HASS\19-0216-4.SDF JOB TITLE: ANDALUCIA (PLAN 25) - 2 HEAD CALC WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 93.5 70.5 29.5 70.9 29.2 45.4 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 29.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 24.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 0.0 SOURCE 45.4 29.2 2 3.0 - - - - 37.6 - - - 3 3.0 - - - - 33.6 - - - 4 5.0 - - - - 31.8 - - - 5 9.0 HOSE STREAM 25.5 5.0 6 15.0 - - - - 21.6 - - - 7 15.0 - - - - 19.2 - - - 8 15.0 - - - - 15.5 - - - 9 15.0 - - - - 12.9 - - - 10 15.0 - - - - 16.4 - - - 11 15.0 - - - - 13.9 - - - 12 15.0 - - - - 12.2 - - - 13 20.0 - - - - 8.4 - - - 14 20.0 K= 4.30 8.0 12.2 15 20.0 K= 4.30 7.8 12.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 4/9/2020 S:\JJ\HASS\19-0216-4.SDF JOB TITLE: ANDALUCIA (PLAN 25) - 2 HEAD CALC PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 29.2 0.995 PL 20.00 PF 6.5 1 0.0 SRCE 45.4 (N/A) 12.0 150 FTG TG PE -1.3 2 3.0 0.0 37.6 0.0 0.224 TL 29.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 3.0 0.0 37.6 0.0 4.0 psi, 29.2 gpm 3 3.0 0.0 33.6 0.0 Pipe: 3 29.2 2.003 PL 120.00 PF 0.9 3 3.0 0.0 33.6 0.0 3.0 150 FTG 2.0 PE -0.9 4 5.0 0.0 31.8 0.0 0.007 TL 122.00 PV Pipe: 4 29.2 1.025 PL 5.00 PF 4.7 4 5.0 0.0 31.8 0.0 11.3 150 FTG 19.0 PE -1.7 5 9.0 H.S. 25.5 5.0 0.194 TL 24.00 PV Pipe: 5 24.2 1.101 PL 6.00 PF 1.3 5 9.0 H.S. 25.5 5.0 8.1 150 FTG 7.0 PE -2.6 6 15.0 0.0 21.6 0.0 0.097 TL 13.00 PV Pipe: 6 24.2 1.101 PL 10.00 PF 2.4 6 15.0 0.0 21.6 0.0 8.1 150 FTG 15.0 PE 0.0 7 15.0 0.0 19.2 0.0 0.097 TL 25.00 PV Pipe: 7 13.1 1.101 PL 79.00 PF 3.7 7 15.0 0.0 19.2 0.0 4.4 150 FTG 40.0 PE 0.0 8 15.0 0.0 15.5 0.0 0.031 TL 119.00 PV Pipe: 8 11.0 1.101 PL 76.00 PF 2.8 7 15.0 0.0 19.2 0.0 3.7 150 FTG 47.0 PE 0.0 10 15.0 0.0 16.4 0.0 0.023 TL 123.00 PV Pipe: 9 13.1 1.101 PL 58.00 PF 2.6 8 15.0 0.0 15.5 0.0 4.4 150 FTG 25.0 PE 0.0 9 15.0 0.0 12.9 0.0 0.031 TL 83.00 PV Pipe: 10 13.1 1.101 PL 27.00 PF 2.3 9 15.0 0.0 12.9 0.0 4.4 150 FTG 47.0 PE -2.2 13 20.0 0.0 8.4 0.0 0.031 TL 74.00 PV Pipe: 11 11.0 1.101 PL 60.00 PF 2.5 10 15.0 0.0 16.4 0.0 3.7 150 FTG 50.0 PE 0.0 11 15.0 0.0 13.9 0.0 0.023 TL 110.00 PV Pipe: 12 11.0 1.101 PL 51.00 PF 1.7 11 15.0 0.0 13.9 0.0 3.7 150 FTG 24.0 PE 0.0 12 15.0 0.0 12.2 0.0 0.023 TL 75.00 PV Pipe: 13 11.0 1.101 PL 39.00 PF 1.6 12 15.0 0.0 12.2 0.0 3.7 150 FTG 33.0 PE -2.2 13 20.0 0.0 8.4 0.0 0.023 TL 72.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 4/9/2020 S:\JJ\HASS\19-0216-4.SDF JOB TITLE: ANDALUCIA (PLAN 25) - 2 HEAD CALC PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 14 12.2 1.101 PL 2.00 PF 0.4 13 20.0 0.0 8.4 0.0 4.1 150 FTG 12.0 PE 0.0 14 20.0 4.3 8.0 12.2 0.027 TL 14.00 PV Pipe: 15 12.0 1.101 PL 11.00 PF 0.6 13 20.0 0.0 8.4 0.0 4.0 150 FTG 12.0 PE 0.0 15 20.0 4.3 7.8 12.0 0.026 TL 23.00 PV NOTES (HASS): (1) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.007 gpm and a maximum imbalance at any node of 0.091 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 12.0 ft/sec at pipe 1. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node 1 under full flow conditions is 61.51 psi with a flow of 35.26 gpm. (6) PIPE FITTINGS TABLE User Pipe Table Name: FSS.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee -------------------------------------------------------- F F45Ell 1.101 2.53 6.33 2.53 6.33 7.59 1.27 12.66 2.53 6.33 1.27 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 4/9/2020 S:\JJ\HASS\19-0216-4.SDF JOB TITLE: ANDALUCIA (PLAN 25) - 2 HEAD CALC PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Ell Tee TEERUN COUPLG EL45 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 2.003 11.00 10.00 1.00 0.00 1.00 2.00 0.00 2.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Ell Tee 1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00 PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Ell Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 4/9/2020 S:\JJ\HASS\19-0216-4.SDF JOB TITLE: ANDALUCIA (PLAN 25) - 2 HEAD CALC WATER SUPPLY ANALYSIS Static: 93.50 psi Resid: 70.50 psi Flow: 29.5 gpm -14.7 0.0 20.0 40.0 60.0 80.0 100.0 20 30 40 50 60 70 80 90 100 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results G A U G E P R E S S U R E ( p s i ) A 1 2 B LEGEND 1 Available pressure 70.93 psi @ 29.2 gpm 2 Required pressure 45.41 psi @ 29.2 gpm A. Source Supply Curve B. System Demand Curve SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 4/9/2020 S:\JJ\HASS\19-0216-4.SDF JOB TITLE: ANDALUCIA (PLAN 25) - 2 HEAD CALC WATER SUPPLY CURVE 96+ * \ \ 88\ \ \ \ 80\ \ \ \ 72\ 0 <-70.5 psi @ 30 gpm | Flow Test Point | P 64+ R | E | S | S 56+ U | R | E | 48+ ( X P | S | I 40+ ) | | | 32+ | | | 24+ | | |============================== 16+ LEGEND " | " | X = Required Water Supply " | 45.41 psi @ 29.2 gpm " 8+ " | 0 = Available Water Supply " | 70.93 psi @ 29.2 gpm " | " 0++-+---+----+-----+------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) DESIGN & DEVELOPMENT DEPARTMENT 78-495 Calle Tampico La Quinta, California 92253 (760) 777-7125 FAX (760) 777-7011  NEW  TENANT IMPROVEMENT PERMIT NO. PROJECT INFORMATION (Please Print) Project Name: Sign: Site Address: Print: City & Zip: Project Description: • Pursuant to a Cooperative Agreement to Provide Fire Services, the Riverside County Fire Department serves as the City’s fire department, and the County designee serves as the City’s fire chief. Applicant recognizes this contracted arrangement and shall comply with County Fire Department directions. APPLICANT/CONTACT INFORMATION CONTRACTOR INFORMATION:  Same as Applicant info Applicant Name: Contractor #: Contact Person: Contact Person: Mailing Address: Mailing Address: City & Zip: City & Zip: Phone Number: Fax : Phone Number: Fax : Email: Email:  ------------  HOURLY@161/HR  $660  HOURLY@161/HR  $780  $982  $418  $1223  HOURLY@161/HR $418  HOURLY@161/HR ------------  HOURLY@161/HR 403  483  HOURLY@161/HR  564  HOURLY@161/HR  $176  $495  $590  HOURLY@161/HR  $659  $418  $579  $1062  $418  $735  HOURLY@161/HR  HOURLY@161/HR  HOURLY@161/HR  HOURLY@161/HR OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org May 19, 2020 Symons Fire Protection INC 12155 Paine PL Poway, CA 92064 Re: Residential Fire Sprinkler Plan Review – Modification specific to Lot 103 (BRES2019-0449) FSS2020-0060 / 81561 Ronda, La Quinta, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 81561 Ronda (Lot 103) PERMIT#: FSS2020-0060 DATE ISSUED: 5/19/2020 DESCRIPTION: RES FIRE SPRINKLER SYSTEM CONTRACTOR: SYMONS FIRE PROTECTION INC. HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible dur ing the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.