Loading...
FSS2020-0067ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT JASON PIVNIK 7356 Fulton Ave.North Hollywood CA 91605 (818)764-7990 jpivnik@deltafireprote ction.com CONDITION TYPE CONTACT DATE ADDED DATE REQUIRED DATE SATISFIED STATUS REMARKS NOTES READY TO ISSUE CHECKLIST STEPHANIE KHATAMI 5/21/2020 5/21/2020 COMPLETE NEEDS TO PAY BUSINESS LICENSE 768751, APPLICATION IN PENDING FILE WITH JACK JACK LIMA CONFIRMED BL HAS BEEN PAID AND IS NOW CURRENT. CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES PLAN CHECK SUBMITTAL RECEIVED STEPHANIE SWANSTROM 5/21/2020 5/21/2020 NEEDS BUSINESS LICENSE CONDITIONS Description: MODIFY FIRE SPRINKLER COVERAGE FOR NEW TENANT Type: FIRE SPRINKLER (WEB)Subtype: TENANT IMPROVEMENT Status: FINALED Applied: 5/21/2020 EPRS Parcel No: 600390029 Site Address: 79024 HIGHWAY 111 STE 103 LA QUINTA,CA 92253 Approved: 6/2/2020 KHET Subdivision: PM 29351 Block: Lot: 11 Issued: Online Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 9/10/2020 KHET Valuation: $2,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Tuesday, February 21, 2023 10:42:11 AM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0067 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL BILL TO Jason Pivnik - Delta Fire Protection 7356 Fulton Ave.North Hollywood Ca 91605 (818)764-7990 jpivnik@deltafireprote ction.com CONTRACTOR DELTA FIRE PROTECTION 7356 FULTON AVE NORTH HOLLYWOOD CA 91605 (818)764-7990 jpivnik@deltafireprote ction.com OWNER INLAND AMERICAN LAQUINTA PAV P O BOX 9271 OAK BROOK IL 92253 (818)764-7990 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS 101-0000-42420 0 $161.00 $161.00 5/21/20 WEB5228 07345G CREDIT Jason Pivnik EPRS FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS PC 101-0000-42420 0 $242.00 $242.00 5/21/20 WEB5228 07345G CREDIT Jason Pivnik EPRS Total Paid for FIRE FEES: $403.00 $403.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 5/21/20 WEB5228 07345G CREDIT Jason Pivnik EPRS Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 5/21/20 WEB5228 07345G CREDIT Jason Pivnik EPRS Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$418.00 $418.00 Printed: Tuesday, February 21, 2023 10:42:11 AM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0067 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 5/21/2020 EtrakitPublicReg 1ST SUBMITTAL : SPRINKLER PLAN 79024 Hwy 111 - FS TI Plan.pdf 1 DOC 5/21/2020 EtrakitPublicReg 1ST SUBMITAL : SPRINKLER SPECS 79024 Hwy 111 - sprinkler pendant spec.pdf 1 DOC 5/21/2020 EtrakitPublicReg 1ST SUBMITTAL : SPECS WALK IN DRY SPRINKLERS 79024 Hwy 111 - Dry Pendant spec.pdf 1 BOND INFORMATION OVERHEAD ROUGH PIPING KHET 7/9/2020 7/9/2020 NOT READY REMOTE VIDEO INSPECTION STILL MOVING PIPE OVERHEAD HYRO KHET 7/9/2020 7/9/2020 NOT READY REMOTE VIDEO INSPECTION NOT READY - NO WATER ON THE SYSTEM. OVERHEAD ROUGH PIPING KHET 7/20/2020 7/20/2020 APPROVED REMOTE VIDEO INSPECTION OVERHEAD HYRO KHET 7/20/2020 7/20/2020 APPROVED REMOTE VIDEO INSPECTION OBSERVED 95 PSI STATIC. (HYDRAULIC CALC PLATE = .20/1500 DENSITY REQUIRING 309 GPM @ 74.2 PSI RESIDUAL) FIRE FINAL**KHET 9/10/2020 9/10/2020 APPROVED REMOTE VIDEO INSPECTION REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) STEPHANIE SWANSTROM 5/21/2020 5/22/2020 5/21/2020 COMPLETE 1ST SUBMITAL RECEIVED. 1ST FIRE (2 WK)KOHL HETRICK 5/21/2020 6/4/2020 6/2/2020 APPROVED SEE ATTACHMENTS PARENT PROJECTS Printed: Tuesday, February 21, 2023 10:42:11 AM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0067 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/2/2020 KOHL HETRICK FSS2020-0067 - APPROVED PLANS.pdf FSS2020-0067 - APPROVED PLANS.pdf 1 DOC 6/2/2020 KOHL HETRICK FSS2020-0067 - COA and JOB CARD.pdf FSS2020-0067 - COA and JOB CARD.pdf 1 Printed: Tuesday, February 21, 2023 10:42:11 AM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0067 APPROVED By: FIRE SAFETY SPECIALIST 06/02/2020 10:54:44 AM The approval of plans and specifications does not permit the violation, deletion, omission or faulty installation of any requirements of Title 24 or any Local Ordinances. Construction shall remain accessible and exposed for inspection purposes until approved by the Fire Department. PERMIT # -FSS2020-0067 DEC 2019 GFS-110 PAGE 1 OF 6 GENERAL DESCRIPTION Globe Series GL-SR sprinklers sheet are Listed Standard Response sprinklers which utilize a 5mm frangible glass bulb as the thermosensitive operating element. These sprinklers are available in upright, pendent, and recessed pendent orientations. They are Listed and Approved as Standard Coverage sprinklers and are to be installed in ac- cordance with the guidelines of the appropriate Installation Standard being mandated by the AHJ (i.e. NFPA 13; FM 2-0). These sprinklers are available in various K-factors, temperatures and finishes as shown. Recessed escutch- eons with either ½” or ¾” vertical adjustment are available (See Approvals Table for appropriate sprinkler/escutcheon combinations and Listings). Some pendent models are ad- ditionally available with a special “Seismic” escutcheon to meet the IBC-ASCE/SEI 7 requirements for use in seismic design categories C, D & E. TECHNICAL DATA SIN • Upright: GL2861, GL4261, GL5661, GL8161, GL8164 • Pendent, Recessed Pendent: GL2851, GL4251, GL5651, GL8151, GL8156 Approvals • cULus • FM • LPCB • CE • See Approval Tables Maximum Working Pressure • 175 psi (12 bar) Minimum Operating Pressure • 7 psi (48 kPa) Temperature Rating • See Approval Tables Materials of Construction • Frame - bronze • Deflector - brass • Screw - brass • Lodgement Wire - stainless steel • Bulb seat - copper • Spring - nickel alloy • Seal - teflon • Bulb - glass with glycerin solution, 5mm • Escutcheon Assembly - carbon steel SERIES GL-SR STANDARD COVERAGE, STANDARD RESPONSE UPRIGHT, PENDENT & RECESSED PENDENT SPRINKLER K-FACTOR: 2.8, 4.2, 5.6, 8.0 FINISHES AND ACCESSORIES Finishes • Factory Bronze • Chrome • White Polyester • Black Polyester - special order • Wax Coated - special order Escutcheons • Brass • Chrome • White Polyester • Black Polyester Wrenches • Standard • Recess • 1/2” NPT • 3/4” NPT OPERATION Upon exposure to heat such as from a fire, the fluid in the bulb expands, compressing the air bubble within the bulb. When the air bubble can no longer compress, the fluid ex- pansion causes breakage of the glass bulb, resulting in re- lease of the water seat assembly, and discharge of water from the sprinkler. PENDENT RECESSED PENDENT RECESSED PENDENT SEISMIC IBC/ASCE/SEI CODES UPRIGHT 4077 Airpark Dr. Standish, MI 48658 • 989-846-4583 • www.globesprinkler.com Technical Support • 989-414-2600 • techservice@globesprinkler.com NOTE: Users should refer to Globe’s web site (www.globesprinkler.com) to ensure that the most recent technical literature is being utilized. NOTE: Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be expected when exposed to corrosive atmospheres. Although corrosion resistant coated sprinklers have passed the standard corrosion tests of the applicable approval agencies, the testing is not representative of all possible corrosive atmo- spheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, humidity, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. SERIES GL-SR STANDARD COVERAGE, STANDARD RESPONSE UPRIGHT, PENDENT & RECESSED PENDENT SPRINKLERS K-FACTOR: 2.8, 4.2, 5.6, 8.0 SERIES GL-SR STANDARD COVERAGE, STANDARD RESPONSE UPRIGHT, PENDENT & RECESSED PENDENT SPRINKLERS K-FACTOR: 2.8, 4.2, 5.6, 8.0 GFS-110 GFS-110 DEC 2019 GFS-110 PAGE 2 OF 6 NOTICE Do not install any bulb-type sprinkler if the bulb is cracked or there is loss of liquid from the bulb. Sprinklers should be tightened enough to obtain a leak-tight joint when water pressure is applied and/or hydrostatic test is performed. Sprinklers should not be overtightened as this can result in distortion and subsequent leak-age. It is recommended not to exceed 14 ft.-lb. (19.0 Nm) torque for 1/2 inch NPT sprinkler threads; 20 ft.-lb. (26.8 Nm) to 3/4 inch NPT threads. Step1. Sprinklers must be properly oriented. Step2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprin- kler fitting. Note: Do not grasp the sprinkler by the deflector. Step3. Wrench-tighten the sprinkler using only the appropriate wrench. Wrenches are only to be applied to the sprinkler wrench flats or wrench hex as applicable. Note: Do not apply wrench to frame arms. INSTALLATION CARE AND MAINTENANCE Prior to installation, it is important to read and follow the “Sprinkler Caution” sheet included within each box of sprin- klers. This sheet (GFS-840) is available on Globe’s web site (www.globesprinkler.com). Store sprinklers in a cool, dry place. Exposure to extreme heat will damage the thermal sensing element, possibly re- sulting in premature activation. Avoid direct sunlight. Replace any sprinkler that shows any corrosion, damage, or loss of liquid from the glass bulb. Do not attempt to paint or alter the sprinkler’s coating in any manner after leaving the manufacturing plant. Do not attach wiring, ropes, decorations or fixtures to a sprinkler. Absence of an escutcheon, used to cover a ceiling hole, may delay sprinkler operation in a fire situation. It is the owner’s responsibility for inspection, testing and maintenance of the fire sprinkler system with all components and devices in accordance with the National Fire Protection Association Pamphlet 25 as well as any other requirements as set forth by the local Authority Having Jurisdiction (AHJ). FIGURE 1: STANDARD SPRINKLER WRENCH ½" NPT P/N 325390 ¾" NPT P/N 312366 FIGURE 2: RECESSED SPRINKLER WRENCH ½" NPT P/N 325391 ¾" NPT P/N 325401 DEC 2019 GFS-110 PAGE 3 OF 6 SIN GL2861 (1) (2)GL4261 (1) (2)GL5661 (1) (2) (3)GL8161 (4)GL8164 (1) (2) (3) ORIENTATION UPRIGHT UPRIGHT UPRIGHT UPRIGHT UPRIGHT K-FACTOR 2.8 (40 metric)4.2 (60 metric)5.6 (80 metric)8.0 (115 metric)8.0 (115 metric) NPT 1/2” (15mm)1/2” (15mm)1/2” (15mm)1/2” (15mm)3/4” (20mm) HAZARD*L.H.L.H ALL ALL ALL cULus 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C) NOTE: 500°F (260°C) available upon request without approvals. FM NA NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C) NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) — LPCB Ref. No. 147c/04 NA NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C) NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C) CE NA NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) TABLE A: UPRIGHT SPRINKLERS (1) AVAILABLE AS cULus LISTED CORROSION RESISTANT WITH POLYESTER COATING. (2) AVAILABLE AS cULus LISTED CORROSION RESISTANT WITH WAX COATING FOR 155°F (68°C), 200°F (93°C) EXCLUDING GL8161. (3) AVAILABLE AS cULus LISTED, FM APPROVED CORROSION RESISTANT WITH WAX COATING FOR 155°F (68°C), 200°F (93°C) (4) FOR RETROFIT USE ONLY. FIGURE 3: SERIES GL-SR UPRIGHT SPRINKLERS GL2861, GL4261, GL5661, GL8161 FIGURE 4: SERIES GL-SR UPRIGHT SPRINKLERS GL8164 *NOTE: Conditions of use for sprinklers within different Occupancy Hazards may vary depending on Density and sprinkler K-Factor. Refer to the appropriate Design Standard being utilized (i.e. NFPA; FM) for these conditions. DEC 2019 GFS-110 PAGE 4 OF 6 SIN GL2851 (1) (2)GL4251 (1) (2)GL5651 (1) (2)GL8151 (4)GL8156 (1) (2) (3) ORIENTATION PENDENT PENDENT PENDENT PENDENT PENDENT K-FACTOR 2.8 (40 metric)4.2 (60 metric)5.6 (80 metric)8.0 (115 metric)8.0 (115 metric) NPT 1/2” (15mm)1/2” (15mm)1/2” (15mm)1/2” (15mm)3/4” (20mm) HAZARD*L.H.L.H ALL ALL ALL cULus 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C) NOTE: 500°F (260°C) available upon request without approvals FM NA NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C) NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C) LPCB Ref. No. 147c/04 NA NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C) NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C) CE NA NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) TABLE B: PENDENT SPRINKLERS (1) AVAILABLE AS cULus LISTED CORROSION RESISTANT WITH POLYESTER COATING. (2) AVAILABLE AS cULus LISTED CORROSION RESISTANT WITH WAX COATING FOR 155°F (68°C), 200°F (93°C) EXCLUDING GL 8151. (3) AVAILABLE AS cULus LISTED, FM APPROVED CORROSION RESISTANT WITH WAX COATING FOR 155°F (68°C), 200°F (93°C) (4) FOR RETROFIT USE ONLY. FIGURE 6: SERIES GL-SR PENDENT SPRINKLERS GL8156 FIGURE 5: SERIES GL-SR PENDENT SPRINKLERS GL2851, GL4251, GL5651, GL8151 *NOTE: Conditions of use for sprinklers within different Occupancy Hazards may vary depending on Density and sprinkler K-Factor. Refer to the appropriate Design Standard being utilized (i.e. NFPA; FM) for these conditions. DEC 2019 GFS-110 PAGE 5 OF 6 SIN GL2851 (1)GL4251 (1)GL5651 (1)GL8151* (1)GL8156 (1) (2) ORIENTATION RECESSED PEND.RECESSED PEND.RECESSED PEND.RECESSED PEND.RECESSED PEND. K-FACTOR 2.8 (40 metric)4.2 (60 metric)5.6 (80 metric)8.0 (115 metric)8.0 (115 metric) NPT 1/2”1/2”1/2”1/2”3/4” HAZARD*L.H.L.H ALL ALL ALL cULus 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) FM Note: ½” Adjustable Recessed Escutcheon only NA NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) LPCB Ref. No. 147c/04 NA NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C) NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C) CE NA NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) TABLE C: RECESSED PENDENT SPRINKLERS 2 15/16" DIA. 2" DIA. MIN. HOLE IN CEILING 1 29/32" DIA. 1/8"1" MIN. 1 3/4" MAX. 1/8" MIN. 5/8" MAX. - 1/2" ADJ. 7/8" MAX. - 3/4" ADJ. REDUCER RETAINER CUP CEILING FIGURE 7: RECESSED ESCUTCHEON A A 4 1/2" (114mm) DIA. 3 7/8" (98mm)- 4"(101mm) DIA. MIN. HOLE IN CEILING 1 29/32" (48mm) DIA. 1/8" (3mm) MIN. 5/8" (16mm) MAX. - 1/2" (12mm) ADJ. 7/8" (22mm) MAX. - 3/4" (19mm) ADJ. 1/4"(6mm) 1" (25mm) MIN. 1 1/2" (38mm) MAX. - 1/2" ADJ. 1 3/4" (44mm) MAX. - 3/4" ADJ. CEILING CUP RETAINER REDUCER FIGURE 8: SEISMIC RECESSED ESCUTCHEON Meets IBC-ASCE/SEI 7 Codes for Seismic areas C, D, & E. TABLE E: SEISMIC ESCUTCHEON 3/4" ADJUSTABLE FRICTION FIT RECESSED ESCUTCHEON (SEISMIC) FINISH 1/2” NPT 3/4” NPT Chrome 326170 326177 White 326172-W 326178-W 1/2" ADJUSTABLE FRICTION FIT RECESSED ESCUTCHEON (SEISMIC) FINISH 1/2” NPT 3/4” NPT Chrome 326201 326208 White 326203-W 326210-W TABLE D: RECESSED ESCUTCHEON 3/4" ADJUSTABLE FRICTION FIT RECESSED ESCUTCHEON FINISH 1/2” NPT 3/4” NPT Chrome 325422 325423 Brass 325424 325420 White Polyester 325426-W 325427-W Black Polyester 325426-B 325427-B Stainless Steel 326140 NA 1/2" ADJUSTABLE FRICTION FIT RECESSED ESCUTCHEON FINISH 1/2” NPT 3/4” NPT Chrome 332071 326040 Brass 332072 326041 White Polyester 332073-W 326042-W Black Polyester 332073-B 326042-B * FOR RETROFIT USE ONLY (1) cULus/LPCB/CE APPROVED WITH 1/2" ADJUSTABLE AND 3/4" ADJUSTABLE RECESSED ESCUTCHEION (2) FM APPROVED FOR BRASS FINISH ONLY *NOTE: Conditions of use for sprinklers within different Occupancy Hazards may vary depending on Density and sprinkler K-Factor. Refer to the appropriate Design Standard being utilized (i.e. NFPA; FM) for these conditions. DEC 2019 GFS-110 PAGE 6 OF 6 PART NUMBER SIN + TEMPERATURE + FINISH XXXX XXX XX SIN TEMPERATURE FINISH GL2861 2861 135 135°F (57°C)01 BRONZE GL4261 4261 155 155°F (68°C)02 CHROME GL5661 5661 175 175°F (79°C)03 WHITE POLYESTER GL8161 8161 200 200°F (93°C)04 BLACK POLYESTER GL8164 8164 286 286°F (141°C)06 WAX COATED GL2851 2851 360 360°F (182°C) GL4251 4251 GL5651 5651 Note: All combinations may not be available. Refer to Listing/Approval Tables for available listed combinations.GL8151 8151 GL8156 8156 TABLE F: PART NUMBER SELECTION GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 Airpark Dr. Standish, MI 48658 • 989-846-4583 • www.globesprinkler.com Technical Support • 989-414-2600 • techservice@globesprinkler.com • Quantity • Finish • Part Number (See TABLE D and TABLE E) • ESCUTCHEON • Quantity • Part Number • WRENCH 1/2” NPT Standard . . . . . . . . . . . . . . . . . . .325390 3/4” NPT Standard . . . . . . . . . . . . . . . . . . .312366 1/2” NPT Recess . . . . . . . . . . . . . . . . . . . .325391 3/4” NPT Recess . . . . . . . . . . . . . . . . . . . .325401 ORDERING INFORMATION • SPRINKLER SPECIFY: • Quantity • SIN • Orientation • Orifice • NPT • Temperature Rating • Finish • Part Number (See TABLE F) DEC 2017 GFS-505b (formerly A-90) EXTENDED STANDARD RESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE PENDENT DESCRIPTION AND OPERATION RECESSED SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING SLEEVE & SKIRT SERIES GL-SR/DRY SURFACE MOUNT CLASSIFICATION AVAILABLE SPRINKLER TEMPERATURES BULB COLOR N.F.P.A. MAXIMUM CEILING TEMPERATURE ORDINARY INTERMEDIATE HIGH 135°F/155°F 175°F/200°F 286°F 57°C/68°C 79°C/93°C 141°C ORANGE/RED YELLOW/GREEN BLUE 100°F 150°F 225°F 38°C 66°C 107°C • Water Working Pressure Rating - 175 psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) • Maximum low temperature glass bulb rating is -67°F (-55°C) • Frame - bronze • Defl ector - brass • Screw - brass • Bulb Seat - brass • Spring - nickel alloy • Seal - tefl on • Retainer - brass • Pin - stainless steel • Torsion Spring - stainless steel • Orifi ce Insert - brass • Bulb - glass with glycerin solution, 5mm size • 3/4”NPT or 1”NPT • Outer Tube - galvanized steel pipe • Inner Tube - stainless steel TECHNICAL DATA • See reverse side for Approvals and Specifi cations. • Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C) 200°F (93°C), 286°F (141°C) The Globe Series GL-SR/DRY Pendent Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples. The Globe Series GL-SR/DRY Pendent Sprinkler utilizes a fran- gible glass ampule sprinkler. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing spring assembly to pivot alongside the inner tube. At this time, water fl ows through the sprinkler and is distributed by the defl ector, in an approved discharge pattern. The heart of Globe's Series GL-SR sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fl uid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. DEC 2017 GFS-505b (formerly A-90) "A" 1" MIN. 3/4"NPT 3/4" MIN. 1"NPT 2 1/2" MIN. DIA. HOLE IN CEILING 3 1/2" DIA.FACE OF CEILING FACE OF TEE FITTING 3 3/4" MIN. 4 3/4" MAX. TEE FITTING ANSI B16.3 CLASS 15 OR ANSI B16.4 CLASS 125 "A" 2 1/2" MIN. 3/4"NPT 2 1/4" MIN. 1"NPT TEE FITTING ANSI B16.3 CLASS 15 OR ANSI B16.4 CLASS 125 FACE OF TEE FITTING FACE OF CEILING TWO PIECE ESCUTCHEON 1/4" 1 1/2" MIN. DIA. HOLE IN CEILING TEE FITTING ANSI B16.3 CLASS 15 OR ANSI B16.4 CLASS 125 "A" 3 1/4" MIN. 3/4"NPT 2 3/4" MIN. 1"NPT 1/8" 2 15/16" DIA. 2" MIN. DIA. HOLE IN CEILING FACE OF CEILING FACE OF TEE FITTING 1 1/4" MIN. 2" MAX.CUP FACE OF TEE FITTING RETAINER 2 1/2" MIN. 4" MAX. "A" 1 3/4" MIN. 3/4"NPT 1 1/2" MIN. 1"NPT 3 7/32" DIA. 1 3/4" MIN. DIA. HOLE IN CEILING FACE OF CEILING TEE FITTING ANSI B16.3 CLASS 15 OR ANSI B16.4 CLASS 125 TWO PIECE ESCUTCHEON NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 1FINISHES AVAILABLE ON SPECIAL ORDER. 2cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. SPECIFICATIONS APPROVALS PRINTED U.S.A. 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 FAX 989-846-9231 www.globesprinkler.com 989-846-4583 1-800-248-0278 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specifi c details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). STANDARD RESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE PENDENT 1SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. *PENDENT STYLE - FM APPROVED 155°F (68°C), 200°F (93°C), AND 286°F (141°C) *RECESSED PENDENT STYLE - FM APPROVED 155°F (68°C) AND 200°F (93°C) ALL: ALL HAZARDS STYLE SIN HAZARD 1 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C)*FM cULus NYC-DOB MEA 101-92-E MIN. DISTANCE BETWEEN SPRINKLERS Feet (Meters) Pendent Recessed Pendent GL5679 ALL X X X X X X X X 6 (1.8)GL5680 ALL X X X X X --- X X GL8179 ALL X X X X X --- X X CROSS SECTIONS EXTENDED SLEEVE & SKIRTRECESSED SURFACE MOUNT IMPORTANT INSTALLATION DATA Globe GL Series Dry Pendent Sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18”. Excessive force may distort the frame thus destroying the unit. When installed in a wet system extending into a freezing area see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs. Please refer to our Dry Caution Sheet for further important installation data. ORDERING INFORMATION • Quantity • SIN • Style • Orifi ce • Temperature • Finishes • Quantity - Wrenches - P/N 333010 • Quantity Recessed Wrenches - P/N 337014 • Escutcheons Desired • Quantity - Protective Caps - P/N 327109-cap (Friction Fit Recessed) “A” Dimension - Distance from face of fi tting to the fi nished ceiling line regardless of escutcheon used. SPECIFY SIN NOMINAL “K” FACTOR THREAD SIZE LENGTH FINISHES GL5679 5.6 (80 metric) 1”NPT cULus Variable to 48” FM Variable to 36” Factory Bronze Chrome White Polyester2 Black Polyester1,2 GL5680 5.6 (80 metric) 3/4”NPT GL8179 8.0 (115 metric) 1”NPT OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org June 2, 2020 Delta Fire Protection Jason Pivnik 7356 Fulton Avenue North Hollywood, CA 91605 Re: TI Fire Sprinkler Plan Review – PIEOLOGY FSS2020-0067 / 79024 HIGHWAY 111 #103, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. The following inspections/tests are required to be witnessed by the Office of the Fire Marshal staff: 1) Overhead Rough: All installed/relocated piping must be visible. 2) Final inspection: All trim is in place, 5-Year certification is current. *Water-flow signal test may be performed during the Final Inspection. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 79024 HIGHWAY 111 #103 PERMIT#: FSS2020-0067 DATE ISSUED: 6/2/2020 DESCRIPTION: TI FIRE SPRINKLER CONTRACTOR: DELTA FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.