FSS2020-0068ADDITIONAL SITES
CHRONOLOGY
CONTACTS
NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL
APPLICANT Daniel Yang 1119 Westminster AVe Alhambra CA 91803 (626)705-4338 daniel@fhfirepro.com
BILL TO F & H FIRE PROTECTION 1119 Westminster AVe Alhambra CA 91803 (626)705-4338 daniel@fhfirepro.com
CONTRACTOR F & H Fire Protection 1119 WESTMINISTER
AVE
ALHAMBRA CA 91803 (626)705-4338 daniel@fhfirepro.com
OWNER INLAND AMERICAN LAQUINTA PAV P O BOX 9271 OAK BROOK IL 92253 (626)705-4338
CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES
PLAN CHECK SUBMITTAL
RECEIVED STEPHANIE SWANSTROM 5/26/2020 5/26/2020
CONDITIONS
Description: LA QUINTA NAIL BAR/ FIRE SPRINKLER T.I.
Type: FIRE SPRINKLER (WEB)Subtype: TENANT IMPROVEMENT Status: FINALED Applied: 5/25/2020 EPRS
Parcel No: 600390029 Site Address: 79070 HIGHWAY 111 STE 103 LA QUINTA,CA 92253 Approved: 6/4/2020 KHET
Subdivision: PM 29351 Block: Lot: 11 Issued: 6/4/2020 KHET
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 8/19/2020 KHET
Valuation: $3,000.00 Occupancy Type: Construction Type: Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details:
FINANCIAL INFORMATION
Printed: Tuesday, February 21, 2023 10:49:19 AM 1 of 3
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2020-0068
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED
DATE
COMPLETED
DATE
RESULT REMARKS NOTES
OVERHEAD ROUGH
PIPING
KHET 6/23/2020 6/23/2020 APPROVED
OVERHEAD HYRO KHET 6/23/2020 6/23/2020 APPROVED
FIRE FINAL**KHET 8/19/2020 8/19/2020 APPROVED
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED
DATE STATUS REMARKS NOTES
PARENT PROJECTS
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
FIRE SPRINKLER
SYSTEMS - TENANT
IMPROVEMENT OVER
10 HEADS
101-0000-42420 0 $161.00 $161.00 5/25/20 WEB5254 00224G CREDIT Daniel Yang EPRS
FIRE SPRINKLER
SYSTEMS - TENANT
IMPROVEMENT OVER
10 HEADS PC
101-0000-42420 0 $242.00 $242.00 5/25/20 WEB5254 00224G CREDIT Daniel Yang EPRS
Total Paid for FIRE FEES: $403.00 $403.00
RECORDS
MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 5/25/20 WEB5254 00224G CREDIT Daniel Yang EPRS
Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00
TECHNOLOGY
ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 5/25/20 WEB5254 00224G CREDIT Daniel Yang EPRS
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
TOTALS:$418.00 $418.00
Printed: Tuesday, February 21, 2023 10:49:19 AM 2 of 3
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2020-0068
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 5/25/2020 EtrakitPublicReg 1ST REVIEW : PLAN 78995 CA-1113-
Model.pdf 1
DOC 5/25/2020 EtrakitPublicReg 1ST REVIEW : CUTSHEET gl5606.pdf 1
DOC 6/4/2020 KOHL HETRICK FSS2020-0068 -
APPROVED PLANS.pdf
FSS2020-0068 -
APPROVED PLANS.pdf 1
DOC 6/4/2020 KOHL HETRICK FSS2020-0068 - COA and
JOB CARD.pdf
FSS2020-0068 - COA and
JOB CARD.pdf 1
BOND INFORMATION
1ST PERMIT TECH (1
DAY)
STEPHANIE
SWANSTROM 5/25/2020 5/26/2020 5/26/2020 COMPLETE
1ST FIRE (2 WK)KOHL
HETRICK 5/25/2020 6/8/2020 6/4/2020 APPROVED SEE ATTACHMENTS
Printed: Tuesday, February 21, 2023 10:49:19 AM 3 of 3
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2020-0068
LA QUINTA NAIL BAR79070 HWY 111 UNIT #103LA QUINTA CAREVISIONSNODATE1119 WESTMINSTER AVE., ALHAMBRA, CA 91803SheetsJobofSheetDateScaleDrawn12"12"(N) SOFFIT AT 9'-6"(N) GYP. BRD. 9'-6"(N) SOFFIT AT 9'-6"(N) SOFFIT AT 9'-6"(N) GYP. BRD. 10'-6(N) GYP. BRD. 10'-2"WAX. 2LAUNDRY ROOM(E) GYP. BRD. 8'-0"RESTROOM(N) SOFFIT AT 9'-6"(N) GYP. BRD. 9'-6"WAX. 1(N) SOFFIT AT 9'-6"(N) SOFFIT AT 9'-6"(N) SOFFIT AT 9'-6"(N) SOFFIT AT 9'-6"(N) GYP. BRD. 10'-6(E) GYP. BRD. 8'-0"RESTROOMFS2020-0068
SEP 2019 GFS-105 PAGE 1 OF 4
GENERAL DESCRIPTION
The Globe Series GL-QR/INCH sprinklers are Listed Quick
Response concealed sprinklers which utilize a 3mm fran-
gible glass bulb as the thermosensitive operating element.
They are Listed and Approved as Standard Coverage
sprinklers and are to be installed in accordance with the
guidelines of the appropriate Installation Standard being
mandated by the AHJ (i.e. NFPA 13). While providing the
optimal aesthetic appeal with the low profile flat cover plate,
the GL-QR/INCH additionally provides the largest vertical
adjustment in the industry of a nominal 1". This nominal 1"
adjustment allows for previously unrecognized installation
flexibility resulting in a clean and tight final "fit" to the ceiling.
The sprinkler is available in four temperatures and the cover
plate is available in two temperatures. Additionally, the cov-
er plate is available in three diameters. The GL-QR/INCH
sprinklers are shipped with a protective cap which is tem-
porararily removed during initial installation and replaced to
protect against ceiling installation damage. The protective
cap is removed and the flat cover plate is installed when the
system is ready for service, See "Installation" steps within
this document.
TECHNICAL DATA
SIN
• GL5606
Approvals
• cULus Listed
• *FM approved for Standard Response only
Maximum Working Pressure
• 175 psi (12 bar)
• Factory tested to 500 psi (34 bar)
Minimum Operating Pressure
• 7 psi (48 kPa)
Temperature Ratings
• 135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate
• 155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate
• 155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate
• 175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate
• 200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate
Materials of Construction
• Frame - bronze • Deflector - brass • Screw - brass
• Lodgement Wire - stainless steel • Bulb seat - copper
• Spring - nickel alloy • Seal - teflon
• Drop Pin -stainless steel
• Bulb - glass with alcohol based solution, 3mm
• Escutcheon Assembly - carbon steel
SPRINKLER SERIES GL-QR/INCH
STANDARD COVERAGE, QUICK RESPONSE*
THE INCH® FLAT PLATE CONCEALED PENDENT
K-FACTOR 5.6
FINISHES AND ACCESSORIES
Flat Plate Finishes
• Chrome • White Painted • Black Painted
• Other finishes - special order
NOTE:
Factory painted cover plates must not be repainted. Non-factory
applied paint may adversely delay or prevent sprinkler operation
in the event of a fire.
Wrench
• P/N 332765
4077 Airpark Dr. Standish, MI 48658 • 989-846-4583 • www.globesprinkler.com
Technical Support • 989-414-2600 • techservice@globesprinkler.com
NOTE:
Users should refer to Globe’s web site (www.globesprinkler.com)
to ensure that the most recent technical literature is being utilized.
3-5/16" DIAMETER
COVER PLATE
2-3/4" DIAMETER
COVER PLATE
4-1/2" DIAMETER COVER PLATE
SEISMIC IBC/ASCE/SEI CODES
OPERATION
The soldered cover plate drops off the retainer assembly
when exposed to heat, as from a fire, that has reached the
plate’s Listed temperature rating exposing the sprinkler
above. Upon the releasing of the cover plate, the deflector,
which is connected to two guide pins, drops down below
the ceiling into its intended position. As heat encompasses
the glass bulb operating element of the sprinkler, the fluid
in the bulb expands, compressing the air bubble within the
bulb. When the air bubble can no longer compress, the fluid
expansion causes breakage of the glass bulb, resulting in
release of the water seat assembly, and discharge of water
from the sprinkler.
SPRINKLER SERIES GL-QR/INCH STANDARD COVERAGE,QUICK RESPONSE THE INCH® FLAT PLATE CONCEALED PENDENT K-FACTOR: 5.6 SPRINKLER SERIES GL-QR/INCH STANDARD COVERAGE, QUICK RESPONSE THE INCH® FLAT PLATE CONCEALED PENDENT K-FACTOR: 5.6 GFS-105 GFS-105
SEP 2019 GFS-105 PAGE 2 OF 4
INSTALLATION
NOTICE
Do not install any bulb-type sprinkler if the bulb is cracked or there is loss of liquid from the bulb. Sprinklers should be tightened enough to obtain a leak-tight joint when water pressure is applied and/or hydrostatic test is performed. Sprinklers should not be overtightened as this can result in distortion and subsequent leak-age. It is recommended not to exceed 14 ft.-lb. (19.0 Nm) torque for 1/2 inch NPT sprinkler threads.
Step 1. Sprinklers must be properly oriented.
Step 2. Remove the Protective Cap.
Step 3. With pipe-thread sealant applied to the pipe
threads, hand tighten the sprinkler into the
sprinkler fitting. Note: Do not grasp the sprin-
kler by the deflector.
Step 4. Wrench-tighten the sprinkler only using the
concealed wrench P/N 332765. Wrenches are
only to be applied to the sprinkler wrench flats
or wrench hex. Note: Do not apply wrench to
frame arms.
Step 5. Replace the Protective Cap by pushing it
upwards until it bottoms out against the Sup-
port Cup. The Protective Cap helps prevent
damage to the Deflector and Drop Pins during
ceiling installation and/or during application of
the finish coating of the ceiling.
NOTICE:
The system is considered Out of Service when
the protective caps are in place.
Step 6. After the ceiling has been completed, remove
and discard the Protective Cap. Verify that
the Deflector moves up and down freely. If the
Sprinkler is damaged or the Deflector does not
move up and down freely, replace the entire
Sprinkler. Do not attempt to modify or repair a
damaged sprinkler.
Step 7. Thread on the Concealed Plate Assembly.
NOTE: As a convenience, either the Hand
Held Installation Tool (P/N 332875) or the
Extension Installation Tool (P/N 332876) may
be used during the above installation proce-
dure. Refer to GFS-860 for information on The
INCH® installation tools.
CARE AND MAINTENANCE
Prior to installation, it is important to read and follow "The
INCH® Sprinkler Caution" sheet (GFS-855) included within
each box of sprinklers. This sheet is available on Globe’s
web site (www.globesprinkler.com).
Always obtain permission from the proper authorities to
shut down the affected fire protection system and notify all
personnel who may be affected by this action before closing
a fire protection system main control valve for maintenance
work on the system that it controls. Sprinklers should only
be cleaned by means of gently dusting with a feather dust-
er; otherwise, non-operation in the event of a fire or inadver-
tent operation may result.
When properly installed, there is a nominal 1/8” (3mm) air
gap between the Cover Plate and the ceiling (FIGURE 1).
This air gap is necessary for proper operation of the sprin-
kler by allowing heat flow from a fire to pass below and
above the Cover Plate to help assure appropriate release of
the Cover Plate in a fire situation. This annular “gap” must
be maintained and should never be sealed or caulked.
Factory painted Cover Plates must not be repainted.
In accordance with NFPA 25, Sprinklers which are found to
be leaking or exhibiting visible signs of corrosion must be
replaced.
Automatic sprinklers must never be painted, plated, coated,
or otherwise altered after leaving the factory.
Care must be exercised to avoid damage to the sprinklers–
before, during, and after installation. Sprinklers damaged
by dropping, striking, wrench slippage, or similar incidents,
must be replaced.
The owner is responsible for the inspection, testing, and
maintenance of their fire protection system and devices in
compliance with this document, as well as with the appli-
cable standards of the National Fire Protection Association
(e.g. NFPA 25), in addition to the standards of any other
authorities having jurisdiction.
SEP 2019 GFS-105 PAGE 3 OF 4
B B
3 7/8" - 4" DIA. MIN.
HOLE IN CEILING
1 7/8" DIA.
4 1/2" DIA.
1" x 1/2"
REDUCER
CUP
SUPPORT SHELL
DEFLECTOR
DROP PIN
CEILING COVER PLATE
2 3/4" MAX.
1 7/8" MIN.
CEILING
FIGURE 2: GL-QR/INCH SEISMIC ESCUTCHEON
INSTALLATION DIMENSIONS
Meets IBC-ASCE/SEI 7 Codes for Seismic areas C, D, & E
FIGURE 3: GL-QR/INCH
ACTIVATED POSITION
FIGURE 1: GL-QR/INCH
INSTALLATION DIMENSIONS
SEP 2019 GFS-105 PAGE 4 OF 4
TABLE A: COVER PLATE PART NUMBERS
GLOBE® PRODUCT WARRANTY
Globe agrees to repair or replace any of its manufactured
products found to be defective in material or workmanship
for a period of one year from date of shipment.
For specific details of our warranty please refer to Price List
Terms and Conditions of Sale (Our Price List).
4077 Airpark Dr. Standish, MI 48658 • 989-846-4583 • www.globesprinkler.com
Technical Support • 989-414-2600 • techservice@globesprinkler.com
FLAT COVER
PLATE SIZES
WHITE
135°F (57°C)
WHITE
155°F (68°C)
CHROME
135°F (57°C)
CHROME
155°F (68°C)
BLACK
135°F (57°C)
BLACK
155°F (68°C)
CUSTOM
135°F (57°C)
CUSTOM
155°F (68°C)
2 3/4” DIA.332726 332731 332724 332729 332726-B 332731-B 332727 332732
3 5/16” DIA.332706 332711 332704 332709 332706-B 332711-B 332707 332712
4 1/2” DIA
(SEISMIC)332822 332828 332821 332827 332822-B 332828-B 332823 332829
ORDERING INFORMATION
• WRENCH
• Quantity • Part Number 332765
• PROTECTIVE CAP
• Quantity • Part Number 332870
GL5606
SPRINKLERS PART NUMBER
135°F (57°C). . . . . . . . . . . . . . . . . . . .560613501
155°F (68°C). . . . . . . . . . . . . . . . . . . .560615501
175°F (79°C). . . . . . . . . . . . . . . . . . . .560617501
200°F (93°C). . . . . . . . . . . . . . . . . . . .560620001
COVER PLATES
SEE TABLE A
SPECIFY
• Quantity • SIN • Temperature Rating • Finish • Part Number
• SPRINKLER
• INSTALLATION TOOL
• Quantity • Part Number
Handheld . . . . . . . . . . . . . . . . . . . . . .332875
Used with Extension . . . . . . . . . . . . . . . . 332876
FIGURE 4: HAND HELD
INSTALLATION TOOL
P/N 332875
FIGURE 5:
INSTALLATION TOOL
USED WITH EXTENSION
P/N 332876
FIGURE 6: PROTECTIVE CAP
P/N 332870
FIGURE 7: CONCEALED WRENCH
P/N 332765
OFFICE OF THE FIRE MARSHAL – LA QUINTA
78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074
• www.rvcfire.org
June 4, 2020
F & H Fire Protection
1119 Westminster Ave
Alhambra, CA 91803
Re: TI Fire Sprinkler Plan Review – LA QUINTA NAIL BAR
FSS2020-0068 / 79070 HIGHWAY 111 #103, LA QUINTA, CA 92253
The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County
Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions.
The following inspections/tests are required to be witnessed by the Office of the Fire Marshal staff:
1) Overhead Rough: All installed/relocated piping must be visible.
2) Final inspection: All trim is in place, 5-Year certification is current.
*Water-flow signal test may be performed during the Final Inspection.
The Fire Department approved plans and conditions letter must be at the job site.
Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for
inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131.
All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal
staff at (760)777-7074.
Kohl Hetrick - Fire Safety Specialist
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
RIVERSIDE COUNTY FIRE PROTECTION PLANNING
RECORD OF INSPECTIONS / PERMIT CARD
THIS CARD IS TO REMAIN ON SITE AT ALL TIMES.
INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE.
JOB
ADDRESS: 79070 Highway 111 #103 PERMIT#: FSS2020-0068 DATE
ISSUED: 6/4/2020
DESCRIPTION: La Quinta Nail Bar – TI CONTRACTOR: F & H Fire Protection
HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS
Thrust block pre-pour Door fan test
UG rough piping Abort test
UG hydro Mechanical shutdown
Flush Detector test
Final E F Deluge/pre-action
SPRINKLER U.G. Final E F
Thrust block pre-pour UST/AST TANK
UG rough piping Installation
UG hydro Removal
Flush Emergency shut off
Final E F Primary piping
FIRE SPRINKLER Secondary piping
Weld inspection Dispensers & shear valves
Overhead rough piping Final E F
Overhead hydro MISC. INSPECTIONS
UG flush / OK to connect Spray booths
Main drain/inspectors’ test Hood/duct extinguishing
High pile storage High pile rack storage
In-rack sprinklers H.P. vents/access/corridors
Hose racks Tract access/hydrant verification
Final E F Access & Address verification
HOOD EXTINGUISHING OTHER CONST. PERMIT
Detection system
Function test
Gas/electrical shut-off
Nozzle model/placement
Fire alarm connection
Final E F
SPRAY BOOTHS FIRE CODE PERMIT(S)
Installation
Air flow test
Mechanical interlock
Extinguishing system
Fire alarm connection
Final E F
FIRE ALARM KNOX SYSTEM
Rough-wire inspection Building Knox box
Function test Gate access Knox box/padlock
Duct detectors/velocity BUILDING INSPECTIONS
24 hr. battery test T/I final
Sprinkler monitoring Shell final
Final E F Final for occupancy
FINAL INSPECTION DATE: INSPECTORS SIGNATURE:
**WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE**
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
INSPECTION NOTES
1. Sway bracing and hangers will be inspected at the time of rough piping inspection.
2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler
Systems)
3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required.
4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test.
5. Contractor shall supply all testing equipment, access and operating instructions at time of test.
6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the
affected system to be covered or hidden.
POLICIES ON FIELD INSPECTIONS
A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when
scheduling inspections. For City of La Quinta inspections call: (760) 777-7131.
B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence
without approved plans.
C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required
to schedule the necessary inspections and be present on site for inspections.
D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not
on site or where previously noted corrections have not been completed.
E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into
the structure until clearance has been granted by the Fire Dept and Building Official.
F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance
has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official.
INSPECTION NOTES:
THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE
AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS.
THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180
DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE.
THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE
REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.