Loading...
FSS2020-0068ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT Daniel Yang 1119 Westminster AVe Alhambra CA 91803 (626)705-4338 daniel@fhfirepro.com BILL TO F & H FIRE PROTECTION 1119 Westminster AVe Alhambra CA 91803 (626)705-4338 daniel@fhfirepro.com CONTRACTOR F & H Fire Protection 1119 WESTMINISTER AVE ALHAMBRA CA 91803 (626)705-4338 daniel@fhfirepro.com OWNER INLAND AMERICAN LAQUINTA PAV P O BOX 9271 OAK BROOK IL 92253 (626)705-4338 CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES PLAN CHECK SUBMITTAL RECEIVED STEPHANIE SWANSTROM 5/26/2020 5/26/2020 CONDITIONS Description: LA QUINTA NAIL BAR/ FIRE SPRINKLER T.I. Type: FIRE SPRINKLER (WEB)Subtype: TENANT IMPROVEMENT Status: FINALED Applied: 5/25/2020 EPRS Parcel No: 600390029 Site Address: 79070 HIGHWAY 111 STE 103 LA QUINTA,CA 92253 Approved: 6/4/2020 KHET Subdivision: PM 29351 Block: Lot: 11 Issued: 6/4/2020 KHET Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 8/19/2020 KHET Valuation: $3,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Tuesday, February 21, 2023 10:49:19 AM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0068 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 6/23/2020 6/23/2020 APPROVED OVERHEAD HYRO KHET 6/23/2020 6/23/2020 APPROVED FIRE FINAL**KHET 8/19/2020 8/19/2020 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS 101-0000-42420 0 $161.00 $161.00 5/25/20 WEB5254 00224G CREDIT Daniel Yang EPRS FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS PC 101-0000-42420 0 $242.00 $242.00 5/25/20 WEB5254 00224G CREDIT Daniel Yang EPRS Total Paid for FIRE FEES: $403.00 $403.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 5/25/20 WEB5254 00224G CREDIT Daniel Yang EPRS Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 5/25/20 WEB5254 00224G CREDIT Daniel Yang EPRS Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$418.00 $418.00 Printed: Tuesday, February 21, 2023 10:49:19 AM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0068 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 5/25/2020 EtrakitPublicReg 1ST REVIEW : PLAN 78995 CA-1113- Model.pdf 1 DOC 5/25/2020 EtrakitPublicReg 1ST REVIEW : CUTSHEET gl5606.pdf 1 DOC 6/4/2020 KOHL HETRICK FSS2020-0068 - APPROVED PLANS.pdf FSS2020-0068 - APPROVED PLANS.pdf 1 DOC 6/4/2020 KOHL HETRICK FSS2020-0068 - COA and JOB CARD.pdf FSS2020-0068 - COA and JOB CARD.pdf 1 BOND INFORMATION 1ST PERMIT TECH (1 DAY) STEPHANIE SWANSTROM 5/25/2020 5/26/2020 5/26/2020 COMPLETE 1ST FIRE (2 WK)KOHL HETRICK 5/25/2020 6/8/2020 6/4/2020 APPROVED SEE ATTACHMENTS Printed: Tuesday, February 21, 2023 10:49:19 AM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0068 LA QUINTA NAIL BAR79070 HWY 111 UNIT #103LA QUINTA CAREVISIONSNODATE1119 WESTMINSTER AVE., ALHAMBRA, CA 91803SheetsJobofSheetDateScaleDrawn12"12"(N) SOFFIT AT 9'-6"(N) GYP. BRD. 9'-6"(N) SOFFIT AT 9'-6"(N) SOFFIT AT 9'-6"(N) GYP. BRD. 10'-6(N) GYP. BRD. 10'-2"WAX. 2LAUNDRY ROOM(E) GYP. BRD. 8'-0"RESTROOM(N) SOFFIT AT 9'-6"(N) GYP. BRD. 9'-6"WAX. 1(N) SOFFIT AT 9'-6"(N) SOFFIT AT 9'-6"(N) SOFFIT AT 9'-6"(N) SOFFIT AT 9'-6"(N) GYP. BRD. 10'-6(E) GYP. BRD. 8'-0"RESTROOMFS2020-0068 SEP 2019 GFS-105 PAGE 1 OF 4 GENERAL DESCRIPTION The Globe Series GL-QR/INCH sprinklers are Listed Quick Response concealed sprinklers which utilize a 3mm fran- gible glass bulb as the thermosensitive operating element. They are Listed and Approved as Standard Coverage sprinklers and are to be installed in accordance with the guidelines of the appropriate Installation Standard being mandated by the AHJ (i.e. NFPA 13). While providing the optimal aesthetic appeal with the low profile flat cover plate, the GL-QR/INCH additionally provides the largest vertical adjustment in the industry of a nominal 1". This nominal 1" adjustment allows for previously unrecognized installation flexibility resulting in a clean and tight final "fit" to the ceiling. The sprinkler is available in four temperatures and the cover plate is available in two temperatures. Additionally, the cov- er plate is available in three diameters. The GL-QR/INCH sprinklers are shipped with a protective cap which is tem- porararily removed during initial installation and replaced to protect against ceiling installation damage. The protective cap is removed and the flat cover plate is installed when the system is ready for service, See "Installation" steps within this document. TECHNICAL DATA SIN • GL5606 Approvals • cULus Listed • *FM approved for Standard Response only Maximum Working Pressure • 175 psi (12 bar) • Factory tested to 500 psi (34 bar) Minimum Operating Pressure • 7 psi (48 kPa) Temperature Ratings • 135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate • 155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate • 155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate • 175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate • 200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate Materials of Construction • Frame - bronze • Deflector - brass • Screw - brass • Lodgement Wire - stainless steel • Bulb seat - copper • Spring - nickel alloy • Seal - teflon • Drop Pin -stainless steel • Bulb - glass with alcohol based solution, 3mm • Escutcheon Assembly - carbon steel SPRINKLER SERIES GL-QR/INCH STANDARD COVERAGE, QUICK RESPONSE* THE INCH® FLAT PLATE CONCEALED PENDENT K-FACTOR 5.6 FINISHES AND ACCESSORIES Flat Plate Finishes • Chrome • White Painted • Black Painted • Other finishes - special order NOTE: Factory painted cover plates must not be repainted. Non-factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Wrench • P/N 332765 4077 Airpark Dr. Standish, MI 48658 • 989-846-4583 • www.globesprinkler.com Technical Support • 989-414-2600 • techservice@globesprinkler.com NOTE: Users should refer to Globe’s web site (www.globesprinkler.com) to ensure that the most recent technical literature is being utilized. 3-5/16" DIAMETER COVER PLATE 2-3/4" DIAMETER COVER PLATE 4-1/2" DIAMETER COVER PLATE SEISMIC IBC/ASCE/SEI CODES OPERATION The soldered cover plate drops off the retainer assembly when exposed to heat, as from a fire, that has reached the plate’s Listed temperature rating exposing the sprinkler above. Upon the releasing of the cover plate, the deflector, which is connected to two guide pins, drops down below the ceiling into its intended position. As heat encompasses the glass bulb operating element of the sprinkler, the fluid in the bulb expands, compressing the air bubble within the bulb. When the air bubble can no longer compress, the fluid expansion causes breakage of the glass bulb, resulting in release of the water seat assembly, and discharge of water from the sprinkler. SPRINKLER SERIES GL-QR/INCH STANDARD COVERAGE,QUICK RESPONSE THE INCH® FLAT PLATE CONCEALED PENDENT K-FACTOR: 5.6 SPRINKLER SERIES GL-QR/INCH STANDARD COVERAGE, QUICK RESPONSE THE INCH® FLAT PLATE CONCEALED PENDENT K-FACTOR: 5.6 GFS-105 GFS-105 SEP 2019 GFS-105 PAGE 2 OF 4 INSTALLATION NOTICE Do not install any bulb-type sprinkler if the bulb is cracked or there is loss of liquid from the bulb. Sprinklers should be tightened enough to obtain a leak-tight joint when water pressure is applied and/or hydrostatic test is performed. Sprinklers should not be overtightened as this can result in distortion and subsequent leak-age. It is recommended not to exceed 14 ft.-lb. (19.0 Nm) torque for 1/2 inch NPT sprinkler threads. Step 1. Sprinklers must be properly oriented. Step 2. Remove the Protective Cap. Step 3. With pipe-thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Note: Do not grasp the sprin- kler by the deflector. Step 4. Wrench-tighten the sprinkler only using the concealed wrench P/N 332765. Wrenches are only to be applied to the sprinkler wrench flats or wrench hex. Note: Do not apply wrench to frame arms. Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Sup- port Cup. The Protective Cap helps prevent damage to the Deflector and Drop Pins during ceiling installation and/or during application of the finish coating of the ceiling. NOTICE: The system is considered Out of Service when the protective caps are in place. Step 6. After the ceiling has been completed, remove and discard the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged or the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. Thread on the Concealed Plate Assembly. NOTE: As a convenience, either the Hand Held Installation Tool (P/N 332875) or the Extension Installation Tool (P/N 332876) may be used during the above installation proce- dure. Refer to GFS-860 for information on The INCH® installation tools. CARE AND MAINTENANCE Prior to installation, it is important to read and follow "The INCH® Sprinkler Caution" sheet (GFS-855) included within each box of sprinklers. This sheet is available on Globe’s web site (www.globesprinkler.com). Always obtain permission from the proper authorities to shut down the affected fire protection system and notify all personnel who may be affected by this action before closing a fire protection system main control valve for maintenance work on the system that it controls. Sprinklers should only be cleaned by means of gently dusting with a feather dust- er; otherwise, non-operation in the event of a fire or inadver- tent operation may result. When properly installed, there is a nominal 1/8” (3mm) air gap between the Cover Plate and the ceiling (FIGURE 1). This air gap is necessary for proper operation of the sprin- kler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation. This annular “gap” must be maintained and should never be sealed or caulked. Factory painted Cover Plates must not be repainted. In accordance with NFPA 25, Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Care must be exercised to avoid damage to the sprinklers– before, during, and after installation. Sprinklers damaged by dropping, striking, wrench slippage, or similar incidents, must be replaced. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (e.g. NFPA 25), in addition to the standards of any other authorities having jurisdiction. SEP 2019 GFS-105 PAGE 3 OF 4 B B 3 7/8" - 4" DIA. MIN. HOLE IN CEILING 1 7/8" DIA. 4 1/2" DIA. 1" x 1/2" REDUCER CUP SUPPORT SHELL DEFLECTOR DROP PIN CEILING COVER PLATE 2 3/4" MAX. 1 7/8" MIN. CEILING FIGURE 2: GL-QR/INCH SEISMIC ESCUTCHEON INSTALLATION DIMENSIONS Meets IBC-ASCE/SEI 7 Codes for Seismic areas C, D, & E FIGURE 3: GL-QR/INCH ACTIVATED POSITION FIGURE 1: GL-QR/INCH INSTALLATION DIMENSIONS SEP 2019 GFS-105 PAGE 4 OF 4 TABLE A: COVER PLATE PART NUMBERS GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 Airpark Dr. Standish, MI 48658 • 989-846-4583 • www.globesprinkler.com Technical Support • 989-414-2600 • techservice@globesprinkler.com FLAT COVER PLATE SIZES WHITE 135°F (57°C) WHITE 155°F (68°C) CHROME 135°F (57°C) CHROME 155°F (68°C) BLACK 135°F (57°C) BLACK 155°F (68°C) CUSTOM 135°F (57°C) CUSTOM 155°F (68°C) 2 3/4” DIA.332726 332731 332724 332729 332726-B 332731-B 332727 332732 3 5/16” DIA.332706 332711 332704 332709 332706-B 332711-B 332707 332712 4 1/2” DIA (SEISMIC)332822 332828 332821 332827 332822-B 332828-B 332823 332829 ORDERING INFORMATION • WRENCH • Quantity • Part Number 332765 • PROTECTIVE CAP • Quantity • Part Number 332870 GL5606 SPRINKLERS PART NUMBER 135°F (57°C). . . . . . . . . . . . . . . . . . . .560613501 155°F (68°C). . . . . . . . . . . . . . . . . . . .560615501 175°F (79°C). . . . . . . . . . . . . . . . . . . .560617501 200°F (93°C). . . . . . . . . . . . . . . . . . . .560620001 COVER PLATES SEE TABLE A SPECIFY • Quantity • SIN • Temperature Rating • Finish • Part Number • SPRINKLER • INSTALLATION TOOL • Quantity • Part Number Handheld . . . . . . . . . . . . . . . . . . . . . .332875 Used with Extension . . . . . . . . . . . . . . . . 332876 FIGURE 4: HAND HELD INSTALLATION TOOL P/N 332875 FIGURE 5: INSTALLATION TOOL USED WITH EXTENSION P/N 332876 FIGURE 6: PROTECTIVE CAP P/N 332870 FIGURE 7: CONCEALED WRENCH P/N 332765 OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org June 4, 2020 F & H Fire Protection 1119 Westminster Ave Alhambra, CA 91803 Re: TI Fire Sprinkler Plan Review – LA QUINTA NAIL BAR FSS2020-0068 / 79070 HIGHWAY 111 #103, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. The following inspections/tests are required to be witnessed by the Office of the Fire Marshal staff: 1) Overhead Rough: All installed/relocated piping must be visible. 2) Final inspection: All trim is in place, 5-Year certification is current. *Water-flow signal test may be performed during the Final Inspection. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 79070 Highway 111 #103 PERMIT#: FSS2020-0068 DATE ISSUED: 6/4/2020 DESCRIPTION: La Quinta Nail Bar – TI CONTRACTOR: F & H Fire Protection HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.