Loading...
FSS2020-0086ADDITIONAL SITES CHRONOLOGY CONDITION TYPE CONTACT DATE ADDED DATE REQUIRED DATE SATISFIED STATUS REMARKS NOTES READY TO ISSUE CHECKLIST BUILDING BUCKET 7/1/2020 8/20/2020 COMPLETE BUSINESS LICENSE REQUIRED BL ISSUED ON 8/20/20 CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE KOHL HETRICK 8/20/2020 8/20/2020 UNABLE TO UPLOAD AS-BUILT PLANS BASED ON ROUGH INSPECTIONS. *TRAKIT WAS DOWN FOR NEARLY 72 HOURS. TELEPHONE CALL KAYLI ALFORD 8/14/2020 8/14/2020 CONTRACTOR CALLED TO SCHEDULE INSPECTION - INFORMED THEM CITY BL IS REQUIRED. CONDITIONS Description: MOUNTAIN VIEW CC REMODEL TI Type: FIRE SPRINKLER (WEB)Subtype: TENANT IMPROVEMENT Status: FINALED Applied: 7/1/2020 ECON Parcel No: 777010009 Site Address: 80375 POMELO LA QUINTA,CA 92253 Approved: 7/30/2020 KHET Subdivision: TR 30357 Block: Lot: 188 Issued: 7/30/2020 KHET Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 11/16/2020 KHET Valuation: $20,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Fire Sprinkler Tenant Improvement Printed: Tuesday, February 21, 2023 3:18:07 PM 1 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0086 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT ZACK MCCOY 31-065 PLANTATION DRIVE THOUSAND PALMS CA 92276 (760)296-2862 ZMCCOY@KINCAIDIND USTRIES.COM BILL TO KINCAID INDUSTRIES INC 31-065 PLANTATION DRIVE THOUSAND PALMS CA 92276 (760)296-2862 AP@KINCAIDINDUSTRI ES.COM CONTRACTOR KINCAID INDUSTRIES INC 31-065 PLANTATION DRIVE THOUSAND PALMS CA 92276 (760)296-2862 INFO@KINCAIDINDUST RIES.COM OWNER MOUNTAIN VIEW CC 14350 N 87TH ST STE 310 LA QUINTA CA 92253 (760)296-2862 NA@NA.COM INSPECTIONS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS 101-0000-42420 0 $161.00 $161.00 7/1/20 WEB5585 845449 CREDIT KINCAID INDUSTRIES INC ECON FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS PC 101-0000-42420 0 $242.00 $242.00 7/1/20 WEB5585 845449 CREDIT KINCAID INDUSTRIES INC ECON Total Paid for FIRE FEES: $403.00 $403.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 7/1/20 WEB5585 845449 CREDIT KINCAID INDUSTRIES INC ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 7/1/20 WEB5585 845449 CREDIT KINCAID INDUSTRIES INC ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$418.00 $418.00 Printed: Tuesday, February 21, 2023 3:18:07 PM 2 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0086 SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 8/20/2020 8/20/2020 REMOTE VIDEO INSPECTION OVERHEAD HYRO KHET 8/20/2020 8/20/2020 FIRE FINAL**KHET 11/16/2020 11/16/2020 APPROVED Spare head and boxes are required, but will be addressed under "Annual Fire Safety Inspection" follow-up. REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) STEPHANIE SWANSTROM 7/1/2020 7/2/2020 7/1/2020 COMPLETE PARENT PROJECTS Printed: Tuesday, February 21, 2023 3:18:07 PM 3 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0086 BOND INFORMATION 1ST FIRE (2 WK)KOHL HETRICK 7/1/2020 7/15/2020 7/13/2020 REVISIONS REQUIRED SEE NOTES & ATTACHMENTS The following corrections are required: 1) Provide a current water supply report (6 months) for bearings of Hydraulic calculations. 2) NFPA 13 Section 23.1.3 (31) essentially requires a mock-up of the required information of Section 25.5 as amended by CFC Chapter 80. Missing information: (1) Occupancy Classification (2) Installing Contractor Information (3) Required Flow and Pressure at water supply source (4) Listing of sprinklers included in area design (K, SIN, Temp, Orif, Orientation) (5) Edition of NFPA 13 for design Will provide a sample that may be used, but shall be shown on plans. 3) New Outdoor Patio area is lower elevation than it's supply point and should be provided with an auxiliary drain. Identify on the plans. 4) Sheet 4 of the plans identifies the proposed use of Vicflex Sprinkler Drops. Plans shall identify the location, series and style to be used. 4)a) Hydraulic Calculations will be required for these areas as the device presents with increased friction losses. 5) Errors were observed in the hydraulic calculations for the outdoor patio. See markups on hydraulic calculations document. 2ND FIRE (1 WK)KOHL HETRICK 7/23/2020 7/30/2020 7/30/2020 APPROVED SEE ATTACHMENTS Printed: Tuesday, February 21, 2023 3:18:07 PM 4 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0086 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 7/1/2020 EtrakitContractor 1ST SUBMITTAL : CALCULATIONS Hydro Calcs.PDF 1 DOC 7/1/2020 EtrakitContractor 1ST SUBMITTAL : PLANS Mountain View CC TI - Fire Sprinkler.pdf 1 DOC 7/1/2020 EtrakitContractor 1ST SUBMITTAL CUT SHEETS Mountain View CC - Div 21 Product Data.pdf 1 DOC 7/23/2020 EtrakitContractor 2ND SUBMITTAL - COMMENTS R1 FS Comments.pdf 1 DOC 7/23/2020 EtrakitContractor 2ND SUBMITTAL - PLANS Mountain View CC TI - Fire Sprinkler (R1).pdf 1 DOC 7/23/2020 EtrakitContractor 2ND SUBMITTAL - CALCS Hydraulic Report (R1).pdf 1 DOC 7/23/2020 EtrakitContractor 2ND SUBMITTAL - CALCS Hydraulic Report (R1)_1.pdf 1 DOC 7/13/2020 KOHL HETRICK FSS2020-0086 - 1ST SUBMITTAL CALCS - CORRECTIONS REQUIRED.pdf FSS2020-0086 - 1ST SUBMITTAL CALCS - CORRECTIONS REQUIRED.pdf 1 DOC 7/13/2020 KOHL HETRICK FSS2020-0086 - 1ST SUBMITTAL PLANS - CORRECTIONS REQUIRED.pdf FSS2020-0086 - 1ST SUBMITTAL PLANS - CORRECTIONS REQUIRED.pdf 1 DOC 7/30/2020 KOHL HETRICK FSS2020-0086 - APPROVED CALCS.pdf FSS2020-0086 - APPROVED CALCS.pdf 1 DOC 7/30/2020 KOHL HETRICK FSS2020-0086 - APPROVED PLANS.pdf FSS2020-0086 - APPROVED PLANS.pdf 1 DOC 7/30/2020 KOHL HETRICK FSS2020-0086 - COA and JOB CARD.pdf FSS2020-0086 - COA and JOB CARD.pdf 1 DOC 11/17/2020 KOHL HETRICK FSS2020-0086 - APPROVED PLANS - 11- 16 FIELD NOTES.pdf FSS2020-0086 - APPROVED PLANS - 11- 16 FIELD NOTES.pdf 1 Printed: Tuesday, February 21, 2023 3:18:07 PM 5 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0086                                                               APPROVED By: FIRE SAFETY SPECIALIST 07/30/2020 11:46:27 AM The approval of plans and specifications does not permit the violation, deletion, omission or faulty installation of any requirements of Title 24 or any Local Ordinances. Construction shall remain accessible and exposed for inspection purposes until approved by the Fire Department. PERMIT # - Hydraulic Summary Report Description: Light Hazard (DA-1) Job Number: 22006 Node Flow(gpm) Total Hose Streams 100.00 Safety MarginRequiredAvailable Node Hose Flow Static Residual Flow Total Demand (gpm)(psi)(psi)(gpm)(psi)(gpm)(psi)(psi)@@Name SU1 98.335 51.752 46.584950.00100.00 95.74098.600 262.34Water Supply Design EngineerJob Number Total Water Required (Including Hose Allowance) 262.34 Maximum Pressure Unbalance In Loops 0.000 Additional Hose Supplies 100.00 Hose Allowance At Source Supplies 5935.09gal Light Hazard 0.10gpm/ft² 168ft² 1500ft² (Actual 911ft²) 9 Occupancy Area of Application Coverage Per SprinklerNumber Of Sprinklers Calculated Density Job Suffix Number Of Nozzles Calculated 0 AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area Left: 48.935 Volume capacity of Dry PipesVolume capacity of Wet Pipes 3.98 between nodes UG2 and SS3 Maximum Velocity Under Ground 17.60 between nodes 7 and 8 Maximum Velocity Above Ground 5.6 K-Factor 16.80 at 9.000 Most Demanding Sprinkler Data System Club HouseLa Quinta, CA 92253 Job Site/Building La Quinta Fire Department80375 Pomelo Verano Dr. AHJ Mountain View CC Club House Job State Certification/License NumberJob Name: ZACK MCCOY22006 Contractor Contractor Number 1 Name of Contractor: KINCAID INDUSTRIES Address 1 31065 PLANTATION DR Address 2 THOUSAND PALMS, CA 92276 Contact Name Contact Title ExtensionPhone 760-343-5457 FAX 760-343-5446 E-mail INFO@KINCAIDINDUSTRIES.COM Web-Site KINCAIDINDUSTRIES.COM INFO Address 3 LIC# 695797 A, C-36, C-16 Address 1 Address 2 Drawing Name Mountain View TI Plan_R1.cad System Flow Demand 162.34 Remote Area(s) Address 3 7/23/2020© M.E.P.CAD, Inc.Page 2AutoSPRINK 2019 v15.1.20.0 4:09:22PM Hydraulic Graph Report Description: Light Hazard (DA-1) Job Number: 22006 95.740 @ 950.00 Residual: Pressure 98.600 Static: Pressure Water Supply at Node SU1 Hydraulic Graph Water Supply at Node SU1 51.752 @ 162.34 51.752 @ 262.34 Available Pressure at Time of Test 98.335 @ 262.34 System Demand System Demand (Including Hose Allowance at Source) © M.E.P.CAD, Inc.7/23/2020 Page 3AutoSPRINK 2019 v15.1.20.0 4:09:23PM Device (gpm) Actual Flow Minimum Flow (gpm)(K) K-Factor (psi) Pressure Summary Of Outflowing Devices Report Description: Light Hazard (DA-1) Job Number: 22006 Sprinkler s101 20.15 16.80 5.6 12.953 Sprinkler s102 18.09 16.80 5.6 10.435 Sprinkler s103 17.34 16.80 5.6 9.589 Sprinkler s104 16.80 16.80 5.6 9.000 Sprinkler s105 16.98 16.80 5.6 9.189 Sprinkler s106 20.18 16.80 5.6 12.989 Sprinkler s107 18.24 16.80 5.6 10.605 Sprinkler s108 17.56 16.80 5.6 9.827 Most Demanding Sprinkler Data © M.E.P.CAD, Inc.7/23/2020 Page 5AutoSPRINK 2019 v15.1.20.0 4:09:24PM FittingsNodeElevation(Foot)Pressure(psi)Discharge(gpm) Node Analysis Report Description: Light Hazard (DA-1) Job Number: 22006 SU1 42'-0 S, E(33'-6)51.752 162.34 s101 55'-7 Spr(-12.953)12.953 20.15 s102 55'-7 Spr(-10.435)10.435 18.09 s103 55'-7 Spr(-9.589)9.589 17.34 s104 55'-7 Spr(-9.000)9.000 16.80 s105 55'-7 Spr(-9.189)9.189 16.98 s106 55'-7 Spr(-12.989)12.989 20.18 s107 55'-7 Spr(-10.605)10.605 18.24 s108 55'-7 Spr(-9.827)9.827 17.56 s109 55'-7 Spr(-9.216)9.216 17.00 UG2 42'-0 T(32'-3)51.735 SS3 42'-0 50.910 BOR4 46'-6 BOR 48.859 5 60'-6 PO(20'-2)34.449 6 60'-6 33.463 7 57'-6 PO(6'-0)28.540 8 57'-6 25.276 9 57'-6 T(5'-0), Tr(1'-0)12.592 10 57'-6 T(5'-0), Tr(1'-0)9.987 11 57'-6 T(5'-0), Tr(1'-0)9.112 12 57'-6 T(5'-0), Tr(1'-0)8.905 13 57'-6 Tr(1'-0), T(6'-0)8.848 14 57'-6 PO(6'-0)27.944 15 57'-6 24.810 16 57'-6 T(5'-0), Tr(1'-0)12.629 17 57'-6 T(5'-0), Tr(1'-0)10.163 18 57'-6 T(5'-0), Tr(1'-0)9.358 19 57'-6 T(6'-0), Tr(1'-0)8.927 © M.E.P.CAD, Inc.7/23/2020 Page 6AutoSPRINK 2019 v15.1.20.0 4:09:25PM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: 22006 Report Description: Light Hazard (DA-1) • • • • • Route 1 • • • • • Pf Pe Pv DR 1.1010 16.80 5.66 0.049282 3'-2 0.745 s104 55'-7 16.80 5.6 9.000 12'-0 -0.840 12 57'-6 8.905 15'-2 150 Sprinkler, E(7'-0), T(5'-0) Pf Pe Pv BL 1.3940 26.47 5.56 0.036216 4'-8 0.206 12 57'-6 9.67 8.905 1'-0 11 57'-6 9.112 5'-8 150 Flow (q) from Route 2 Tr(1'-0) Pf Pe Pv BL 1.3940 43.81 9.21 0.091990 8'-6 0.875 11 57'-6 17.34 9.112 1'-0 10 57'-6 9.987 9'-6 150 Flow (q) from Route 4 Tr(1'-0) Pf Pe Pv BL 1.3940 61.90 13.01 0.174362 13'-11 2.605 10 57'-6 18.09 9.987 1'-0 9 57'-6 12.592 14'-11 150 Flow (q) from Route 6 Tr(1'-0) Pf Pe Pv BL 1.3940 82.06 17.25 0.293704 40'-2 12.685 9 57'-6 20.15 12.592 3'-0 8 57'-6 25.276 43'-2 150 Flow (q) from Route 8 3Tr(1'-0) Pf Pe Pv BL 1.3800 82.06 17.60 0.466167 1'-0 3.263 8 57'-6 25.276 6'-0 7 57'-6 28.540 7'-0 120 PO(6'-0) Pf Pe Pv CM 2.1570 162.34 14.25 0.187098 16'-0 6.224 7 57'-6 80.28 28.540 17'-3 -1.301 6 60'-6 33.463 33'-3 120 Flow (q) from Route 3 4fE(4'-4) Pf Pe Pv CM 3.2600 162.34 6.24 0.025035 12'-6 0.986 6 60'-6 33.463 26'-11 5 60'-6 34.449 39'-5 120 fE(6'-9), PO(20'-2) Pf Pe Pv CM 3.2600 162.34 6.24 0.025035 257'-11 8.340 5 60'-6 34.449 75'-3 6.069 BOR4 46'-6 48.859 333'-2 120 4E(9'-5), fT(17'-6), 3fE(6'-9), BOR Pf Pe Pv MS 4.2600 162.34 3.65 0.004502 10'-6 0.101 BOR4 46'-6 48.859 11'-11 1.951 SS3 42'-0 50.910 22'-5 150 LtE(11'-11) Pf Pe Pv UG 4.0800 162.34 3.98 0.005555 93'-7 0.824 SS3 42'-0 50.910 54'-9 UG2 42'-0 51.735 148'-4 150 E(16'-1), EE(6'-5), T(32'-3) Pf Pe Pv UG 8.5500 162.34 0.91 0.000172 48'-3 0.017 UG2 42'-0 51.735 50'-3 SU1 42'-0 51.752 98'-5 140 Ee2(16'-9), S, E(33'-6) 262.34 100.00 Hose Allowance At Source SU1 • • • • • Route 2 • • • • • Pf Pe Pv DR 1.1010 16.98 5.72 0.050237 2'-11 0.499 s105 55'-7 16.98 5.6 9.189 7'-0 -0.840 13 57'-6 8.848 9'-11 150 Sprinkler, E(7'-0) Pf Pe Pv BL 1.3940 9.67 2.03 0.005621 8'-3 0.058 13 57'-6 8.848 2'-0 12 57'-6 8.905 10'-3 150 Tr(1'-0) Tr(1'-0) • • • • • Route 3 • • • • • Pf Pe Pv DR 1.1010 17.00 5.73 0.050376 2'-11 0.551 s109 55'-7 17.00 5.6 9.216 8'-0 -0.840 19 57'-6 8.927 10'-11 150 Sprinkler, E(7'-0), Tr(1'-0) Pf Pe Pv BL 1.3940 24.31 5.11 0.030930 12'-11 0.431 19 57'-6 7.31 8.927 1'-0 18 57'-6 9.358 13'-11 150 Flow (q) from Route 10 Tr(1'-0) Pf Pe Pv BL 1.3940 41.86 8.80 0.084559 8'-6 0.805 18 57'-6 17.56 9.358 1'-0 17 57'-6 10.163 9'-6 150 Flow (q) from Route 5 Tr(1'-0) Pf Pe Pv BL 1.3940 60.10 12.63 0.165081 13'-11 2.466 17 57'-6 18.24 10.163 1'-0 16 57'-6 12.629 14'-11 150 Flow (q) from Route 7 Tr(1'-0) Pf Pe Pv BL 1.3940 80.28 16.88 0.282055 40'-2 12.182 16 57'-6 20.18 12.629 3'-0 15 57'-6 24.810 43'-2 150 Flow (q) from Route 9 3Tr(1'-0) Pf Pe Pv BL 1.3800 80.28 17.22 0.447678 1'-0 3.134 15 57'-6 24.810 6'-0 14 57'-6 27.944 7'-0 120 PO(6'-0) © M.E.P.CAD, Inc.7/23/2020 Page 7AutoSPRINK 2019 v15.1.20.0 4:09:26PM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: 22006 Report Description: Light Hazard (DA-1) Pf Pe Pv CM 2.1570 80.28 7.05 0.050854 11'-8 0.595 14 57'-6 27.944 7 57'-6 28.540 11'-8 120 • • • • • Route 4 • • • • • Pf Pe Pv DR 1.1010 17.34 5.84 0.052259 1'-11 0.363 s103 55'-7 17.34 5.6 9.589 5'-0 -0.840 11 57'-6 9.112 6'-11 150 Sprinkler, T(5'-0) • • • • • Route 5 • • • • • Pf Pe Pv DR 1.1010 17.56 5.92 0.053459 1'-11 0.371 s108 55'-7 17.56 5.6 9.827 5'-0 -0.840 18 57'-6 9.358 6'-11 150 Sprinkler, T(5'-0) • • • • • Route 6 • • • • • Pf Pe Pv DR 1.1010 18.09 6.10 0.056510 1'-11 0.392 s102 55'-7 18.09 5.6 10.435 5'-0 -0.840 10 57'-6 9.987 6'-11 150 Sprinkler, T(5'-0) • • • • • Route 7 • • • • • Pf Pe Pv DR 1.1010 18.24 6.15 0.057360 1'-11 0.398 s107 55'-7 18.24 5.6 10.605 5'-0 -0.840 17 57'-6 10.163 6'-11 150 Sprinkler, T(5'-0) • • • • • Route 8 • • • • • Pf Pe Pv DR 1.1010 20.15 6.79 0.069016 1'-11 0.479 s101 55'-7 20.15 5.6 12.953 5'-0 -0.840 9 57'-6 12.592 6'-11 150 Sprinkler, T(5'-0) • • • • • Route 9 • • • • • Pf Pe Pv DR 1.1010 20.18 6.80 0.069193 1'-11 0.480 s106 55'-7 20.18 5.6 12.989 5'-0 -0.840 16 57'-6 12.629 6'-11 150 Sprinkler, T(5'-0) • • • • • Route 10 • • • • • Pf Pe Pv BL 1.3940 7.31 1.54 0.003346 11'-8 0.079 13 57'-6 8.848 12'-0 19 57'-6 8.927 23'-8 150 T(6'-0) T(6'-0) 1.51 4.87 )(150 1.33 140 1.16 130 0.713 100 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc.7/23/2020 Page 8AutoSPRINK 2019 v15.1.20.0 4:09:26PM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: 22006 Report Description: Light Hazard (DA-1) Pipe Type Legend AO Arm-Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Units Legend Diameter Inch Elevation Foot Flow gpm Discharge gpm Velocity fps Pressure psi Length Foot Friction Loss psi/Foot HWC Hazen-Williams Constant Pt Total pressure at a point in a pipe Pn Normal pressure at a point in a pipe Pf Pressure loss due to friction between points Pe Pressure due to elevation difference between indicated points Pv Velocity pressure at a point in a pipe Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap © M.E.P.CAD, Inc.7/23/2020 Page 9AutoSPRINK 2019 v15.1.20.0 4:09:26PM Riser Tag Report Description: Light Hazard (DA-1) Job Number: 22006 Job Total Demand Flow(gpm): Static Pressure(psi): Residual Pressure(psi): Supply Flow(gpm): Mountain View CC Club House Occupancy: Number Of Sprinklers Calculated: K-Factor: Orifice Size: Average Density: Area of Application: Light Hazard 112 5.6 0.5 0.10gpm/ft² 0.18gpm/ft² 1500ft² (Actual 911ft²) 98.600 95.740 950.00 Design Density: 80375 Pomelo Verano Dr. La Quinta, CA 92253 Design Basis 9 Water Supply Information At Time Of Design Total Sprinklers: 48.859 Total Demand Flow(gpm): Pressure(psi): 162.34 Demand At Base Of Riser (BOR) 262.34 Number Of Nozzles Calculated: 51.752Total Demand Pressure(psi): 0 © M.E.P.CAD, Inc.7/23/2020 Page 11AutoSPRINK 2019 v15.1.20.0 4:09:27PM Flow Diagram (Top View) Report Description: Light Hazard (DA-1) Job Number: 22006 © M.E.P.CAD, Inc.7/23/2020 Page 12AutoSPRINK 2019 v15.1.20.0 4:09:28PM Flow Diagram (Current View) Report Description: Light Hazard (DA-1) Job Number: 22006 © M.E.P.CAD, Inc.7/23/2020 Page 14AutoSPRINK 2019 v15.1.20.0 4:09:30PM Hydraulic Overview Job Number: 22006 Report Description: Light Hazard (DA-1) Node Flow(gpm)Hose Flow(gpm)Static(psi)Residual(psi)Name SU1 950.00 100.00 98.600 95.740Water Supply Identifier Pressure(psi)K-Factor(K)Flow(gpm) BOR 48.859 23.22 162.34 Job System Supplies Check Point Gauges 22006 ZACK MCCOY Mountain View CC Club House 80375 Pomelo Verano Dr. La Quinta, CA 92253 7603435457 Mountain View TI Plan_R1.cad La Quinta Fire Department Club House Job Name: Address 1 Address 2 Design Engineer Phone FAX State Certification/License Number AHJ Job Site/Building Most Demanding Sprinkler Data Coverage Per Sprinkler Total Demand Area of Application Hose Streams Number Of Sprinklers Calculated Pressure Result Job Number 262.34 @ 51.752 Water Supply at Node SU1 (950.00, 0.00, 98.600, 95.740) 0.10gpm/ft² 5.6 K-Factor 16.80 at 9.000 168ft² 1500ft² (Actual 911ft²) 9 Density +46.584 (47.4%) Address 3 System Pressure Demand System Flow Demand 51.752 162.34 100.00 0 Number Of Sprinklers Calculated © M.E.P.CAD, Inc.7/23/2020 Page 1AutoSPRINK 2019 v15.1.20.0 4:09:20PM Hydraulic Summary Report Description: Light Hazard (DA-1) Job Number: 22006 Node Flow(gpm) Total Hose Streams 100.00 Safety MarginRequiredAvailable Node Hose Flow Static Residual Flow Total Demand (gpm)(psi)(psi)(gpm)(psi)(gpm)(psi)(psi)@@Name SU1 98.335 51.752 46.584950.00100.00 95.74098.600 262.34Water Supply Design EngineerJob Number Total Water Required (Including Hose Allowance) 262.34 Maximum Pressure Unbalance In Loops 0.000 Additional Hose Supplies 100.00 Hose Allowance At Source Supplies 5935.09gal Light Hazard 0.10gpm/ft² 168ft² 1500ft² (Actual 911ft²) 9 Occupancy Area of Application Coverage Per SprinklerNumber Of Sprinklers Calculated Density Job Suffix Number Of Nozzles Calculated 0 AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area Left: 48.935 Volume capacity of Dry PipesVolume capacity of Wet Pipes 3.98 between nodes UG2 and SS3 Maximum Velocity Under Ground 17.60 between nodes 7 and 8 Maximum Velocity Above Ground 5.6 K-Factor 16.80 at 9.000 Most Demanding Sprinkler Data System Club HouseLa Quinta, CA 92253 Job Site/Building La Quinta Fire Department80375 Pomelo Verano Dr. AHJ Mountain View CC Club House Job State Certification/License NumberJob Name: ZACK MCCOY22006 Contractor Contractor Number 1 Name of Contractor: KINCAID INDUSTRIES Address 1 31065 PLANTATION DR Address 2 THOUSAND PALMS, CA 92276 Contact Name Contact Title ExtensionPhone 760-343-5457 FAX 760-343-5446 E-mail INFO@KINCAIDINDUSTRIES.COM Web-Site KINCAIDINDUSTRIES.COM INFO Address 3 LIC# 695797 A, C-36, C-16 Address 1 Address 2 Drawing Name Mountain View TI Plan_R1.cad System Flow Demand 162.34 Remote Area(s) Address 3 7/23/2020© M.E.P.CAD, Inc.Page 2AutoSPRINK 2019 v15.1.20.0 4:09:22PM Hydraulic Graph Report Description: Light Hazard (DA-1) Job Number: 22006 95.740 @ 950.00 Residual: Pressure 98.600 Static: Pressure Water Supply at Node SU1 Hydraulic Graph Water Supply at Node SU1 51.752 @ 162.34 51.752 @ 262.34 Available Pressure at Time of Test 98.335 @ 262.34 System Demand System Demand (Including Hose Allowance at Source) © M.E.P.CAD, Inc.7/23/2020 Page 3AutoSPRINK 2019 v15.1.20.0 4:09:23PM Device (gpm) Actual Flow Minimum Flow (gpm)(K) K-Factor (psi) Pressure Summary Of Outflowing Devices Report Description: Light Hazard (DA-1) Job Number: 22006 Sprinkler s101 20.15 16.80 5.6 12.953 Sprinkler s102 18.09 16.80 5.6 10.435 Sprinkler s103 17.34 16.80 5.6 9.589 Sprinkler s104 16.80 16.80 5.6 9.000 Sprinkler s105 16.98 16.80 5.6 9.189 Sprinkler s106 20.18 16.80 5.6 12.989 Sprinkler s107 18.24 16.80 5.6 10.605 Sprinkler s108 17.56 16.80 5.6 9.827 Most Demanding Sprinkler Data © M.E.P.CAD, Inc.7/23/2020 Page 5AutoSPRINK 2019 v15.1.20.0 4:09:24PM FittingsNodeElevation(Foot)Pressure(psi)Discharge(gpm) Node Analysis Report Description: Light Hazard (DA-1) Job Number: 22006 SU1 42'-0 S, E(33'-6)51.752 162.34 s101 55'-7 Spr(-12.953)12.953 20.15 s102 55'-7 Spr(-10.435)10.435 18.09 s103 55'-7 Spr(-9.589)9.589 17.34 s104 55'-7 Spr(-9.000)9.000 16.80 s105 55'-7 Spr(-9.189)9.189 16.98 s106 55'-7 Spr(-12.989)12.989 20.18 s107 55'-7 Spr(-10.605)10.605 18.24 s108 55'-7 Spr(-9.827)9.827 17.56 s109 55'-7 Spr(-9.216)9.216 17.00 UG2 42'-0 T(32'-3)51.735 SS3 42'-0 50.910 BOR4 46'-6 BOR 48.859 5 60'-6 PO(20'-2)34.449 6 60'-6 33.463 7 57'-6 PO(6'-0)28.540 8 57'-6 25.276 9 57'-6 T(5'-0), Tr(1'-0)12.592 10 57'-6 T(5'-0), Tr(1'-0)9.987 11 57'-6 T(5'-0), Tr(1'-0)9.112 12 57'-6 T(5'-0), Tr(1'-0)8.905 13 57'-6 Tr(1'-0), T(6'-0)8.848 14 57'-6 PO(6'-0)27.944 15 57'-6 24.810 16 57'-6 T(5'-0), Tr(1'-0)12.629 17 57'-6 T(5'-0), Tr(1'-0)10.163 18 57'-6 T(5'-0), Tr(1'-0)9.358 19 57'-6 T(6'-0), Tr(1'-0)8.927 © M.E.P.CAD, Inc.7/23/2020 Page 6AutoSPRINK 2019 v15.1.20.0 4:09:25PM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: 22006 Report Description: Light Hazard (DA-1) • • • • • Route 1 • • • • • Pf Pe Pv DR 1.1010 16.80 5.66 0.049282 3'-2 0.745 s104 55'-7 16.80 5.6 9.000 12'-0 -0.840 12 57'-6 8.905 15'-2 150 Sprinkler, E(7'-0), T(5'-0) Pf Pe Pv BL 1.3940 26.47 5.56 0.036216 4'-8 0.206 12 57'-6 9.67 8.905 1'-0 11 57'-6 9.112 5'-8 150 Flow (q) from Route 2 Tr(1'-0) Pf Pe Pv BL 1.3940 43.81 9.21 0.091990 8'-6 0.875 11 57'-6 17.34 9.112 1'-0 10 57'-6 9.987 9'-6 150 Flow (q) from Route 4 Tr(1'-0) Pf Pe Pv BL 1.3940 61.90 13.01 0.174362 13'-11 2.605 10 57'-6 18.09 9.987 1'-0 9 57'-6 12.592 14'-11 150 Flow (q) from Route 6 Tr(1'-0) Pf Pe Pv BL 1.3940 82.06 17.25 0.293704 40'-2 12.685 9 57'-6 20.15 12.592 3'-0 8 57'-6 25.276 43'-2 150 Flow (q) from Route 8 3Tr(1'-0) Pf Pe Pv BL 1.3800 82.06 17.60 0.466167 1'-0 3.263 8 57'-6 25.276 6'-0 7 57'-6 28.540 7'-0 120 PO(6'-0) Pf Pe Pv CM 2.1570 162.34 14.25 0.187098 16'-0 6.224 7 57'-6 80.28 28.540 17'-3 -1.301 6 60'-6 33.463 33'-3 120 Flow (q) from Route 3 4fE(4'-4) Pf Pe Pv CM 3.2600 162.34 6.24 0.025035 12'-6 0.986 6 60'-6 33.463 26'-11 5 60'-6 34.449 39'-5 120 fE(6'-9), PO(20'-2) Pf Pe Pv CM 3.2600 162.34 6.24 0.025035 257'-11 8.340 5 60'-6 34.449 75'-3 6.069 BOR4 46'-6 48.859 333'-2 120 4E(9'-5), fT(17'-6), 3fE(6'-9), BOR Pf Pe Pv MS 4.2600 162.34 3.65 0.004502 10'-6 0.101 BOR4 46'-6 48.859 11'-11 1.951 SS3 42'-0 50.910 22'-5 150 LtE(11'-11) Pf Pe Pv UG 4.0800 162.34 3.98 0.005555 93'-7 0.824 SS3 42'-0 50.910 54'-9 UG2 42'-0 51.735 148'-4 150 E(16'-1), EE(6'-5), T(32'-3) Pf Pe Pv UG 8.5500 162.34 0.91 0.000172 48'-3 0.017 UG2 42'-0 51.735 50'-3 SU1 42'-0 51.752 98'-5 140 Ee2(16'-9), S, E(33'-6) 262.34 100.00 Hose Allowance At Source SU1 • • • • • Route 2 • • • • • Pf Pe Pv DR 1.1010 16.98 5.72 0.050237 2'-11 0.499 s105 55'-7 16.98 5.6 9.189 7'-0 -0.840 13 57'-6 8.848 9'-11 150 Sprinkler, E(7'-0) Pf Pe Pv BL 1.3940 9.67 2.03 0.005621 8'-3 0.058 13 57'-6 8.848 2'-0 12 57'-6 8.905 10'-3 150 Tr(1'-0) Tr(1'-0) • • • • • Route 3 • • • • • Pf Pe Pv DR 1.1010 17.00 5.73 0.050376 2'-11 0.551 s109 55'-7 17.00 5.6 9.216 8'-0 -0.840 19 57'-6 8.927 10'-11 150 Sprinkler, E(7'-0), Tr(1'-0) Pf Pe Pv BL 1.3940 24.31 5.11 0.030930 12'-11 0.431 19 57'-6 7.31 8.927 1'-0 18 57'-6 9.358 13'-11 150 Flow (q) from Route 10 Tr(1'-0) Pf Pe Pv BL 1.3940 41.86 8.80 0.084559 8'-6 0.805 18 57'-6 17.56 9.358 1'-0 17 57'-6 10.163 9'-6 150 Flow (q) from Route 5 Tr(1'-0) Pf Pe Pv BL 1.3940 60.10 12.63 0.165081 13'-11 2.466 17 57'-6 18.24 10.163 1'-0 16 57'-6 12.629 14'-11 150 Flow (q) from Route 7 Tr(1'-0) Pf Pe Pv BL 1.3940 80.28 16.88 0.282055 40'-2 12.182 16 57'-6 20.18 12.629 3'-0 15 57'-6 24.810 43'-2 150 Flow (q) from Route 9 3Tr(1'-0) Pf Pe Pv BL 1.3800 80.28 17.22 0.447678 1'-0 3.134 15 57'-6 24.810 6'-0 14 57'-6 27.944 7'-0 120 PO(6'-0) © M.E.P.CAD, Inc.7/23/2020 Page 7AutoSPRINK 2019 v15.1.20.0 4:09:26PM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: 22006 Report Description: Light Hazard (DA-1) Pf Pe Pv CM 2.1570 80.28 7.05 0.050854 11'-8 0.595 14 57'-6 27.944 7 57'-6 28.540 11'-8 120 • • • • • Route 4 • • • • • Pf Pe Pv DR 1.1010 17.34 5.84 0.052259 1'-11 0.363 s103 55'-7 17.34 5.6 9.589 5'-0 -0.840 11 57'-6 9.112 6'-11 150 Sprinkler, T(5'-0) • • • • • Route 5 • • • • • Pf Pe Pv DR 1.1010 17.56 5.92 0.053459 1'-11 0.371 s108 55'-7 17.56 5.6 9.827 5'-0 -0.840 18 57'-6 9.358 6'-11 150 Sprinkler, T(5'-0) • • • • • Route 6 • • • • • Pf Pe Pv DR 1.1010 18.09 6.10 0.056510 1'-11 0.392 s102 55'-7 18.09 5.6 10.435 5'-0 -0.840 10 57'-6 9.987 6'-11 150 Sprinkler, T(5'-0) • • • • • Route 7 • • • • • Pf Pe Pv DR 1.1010 18.24 6.15 0.057360 1'-11 0.398 s107 55'-7 18.24 5.6 10.605 5'-0 -0.840 17 57'-6 10.163 6'-11 150 Sprinkler, T(5'-0) • • • • • Route 8 • • • • • Pf Pe Pv DR 1.1010 20.15 6.79 0.069016 1'-11 0.479 s101 55'-7 20.15 5.6 12.953 5'-0 -0.840 9 57'-6 12.592 6'-11 150 Sprinkler, T(5'-0) • • • • • Route 9 • • • • • Pf Pe Pv DR 1.1010 20.18 6.80 0.069193 1'-11 0.480 s106 55'-7 20.18 5.6 12.989 5'-0 -0.840 16 57'-6 12.629 6'-11 150 Sprinkler, T(5'-0) • • • • • Route 10 • • • • • Pf Pe Pv BL 1.3940 7.31 1.54 0.003346 11'-8 0.079 13 57'-6 8.848 12'-0 19 57'-6 8.927 23'-8 150 T(6'-0) T(6'-0) 1.51 4.87 )(150 1.33 140 1.16 130 0.713 100 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc.7/23/2020 Page 8AutoSPRINK 2019 v15.1.20.0 4:09:26PM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: 22006 Report Description: Light Hazard (DA-1) Pipe Type Legend AO Arm-Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Units Legend Diameter Inch Elevation Foot Flow gpm Discharge gpm Velocity fps Pressure psi Length Foot Friction Loss psi/Foot HWC Hazen-Williams Constant Pt Total pressure at a point in a pipe Pn Normal pressure at a point in a pipe Pf Pressure loss due to friction between points Pe Pressure due to elevation difference between indicated points Pv Velocity pressure at a point in a pipe Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap © M.E.P.CAD, Inc.7/23/2020 Page 9AutoSPRINK 2019 v15.1.20.0 4:09:26PM Riser Tag Report Description: Light Hazard (DA-1) Job Number: 22006 Job Total Demand Flow(gpm): Static Pressure(psi): Residual Pressure(psi): Supply Flow(gpm): Mountain View CC Club House Occupancy: Number Of Sprinklers Calculated: K-Factor: Orifice Size: Average Density: Area of Application: Light Hazard 112 5.6 0.5 0.10gpm/ft² 0.18gpm/ft² 1500ft² (Actual 911ft²) 98.600 95.740 950.00 Design Density: 80375 Pomelo Verano Dr. La Quinta, CA 92253 Design Basis 9 Water Supply Information At Time Of Design Total Sprinklers: 48.859 Total Demand Flow(gpm): Pressure(psi): 162.34 Demand At Base Of Riser (BOR) 262.34 Number Of Nozzles Calculated: 51.752Total Demand Pressure(psi): 0 © M.E.P.CAD, Inc.7/23/2020 Page 11AutoSPRINK 2019 v15.1.20.0 4:09:27PM Flow Diagram (Top View) Report Description: Light Hazard (DA-1) Job Number: 22006 © M.E.P.CAD, Inc.7/23/2020 Page 12AutoSPRINK 2019 v15.1.20.0 4:09:28PM Flow Diagram (Current View) Report Description: Light Hazard (DA-1) Job Number: 22006 © M.E.P.CAD, Inc.7/23/2020 Page 14AutoSPRINK 2019 v15.1.20.0 4:09:30PM Hydraulic Overview Job Number: 22006 Report Description: Light Hazard (DA-1) Node Flow(gpm)Hose Flow(gpm)Static(psi)Residual(psi)Name 1 1250.00 100.00 126.000 125.000Water Supply Identifier Pressure(psi)K-Factor(K)Flow(gpm) Job System Supplies Check Point Gauges 22006 ZACK MCCOY Mountain View CC Club House 80375 Pomelo Verano Dr. La Quinta, CA 92253 7603435457 Mountain View TI Plan.cad CAL Fire Club House Job Name: Address 1 Address 2 Design Engineer Phone FAX State Certification/License Number AHJ Job Site/Building Most Demanding Sprinkler Data Coverage Per Sprinkler Total Demand Area of Application Hose Streams Number Of Sprinklers Calculated Pressure Result Job Number 261.90 @ 52.611 Water Supply at Node 1 (1250.00, 0.00, 126.000, 125.000) 0.10gpm/ft² 5.6 K-Factor 16.80 at 9.000 168ft² 1500ft² (Actual 911ft²) 9 Density +73.334 (58.2%) Address 3 System Pressure Demand System Flow Demand 52.611 161.90 100.00 0 Number Of Sprinklers Calculated © M.E.P.CAD, Inc.6/11/2020 Page 1AutoSPRINK 2019 v15.1.20.0 9:53:33AM Hydraulic Summary Report Description: Light Hazard (DA-1) Job Number: 22006 Node Flow(gpm) Total Hose Streams 100.00 Safety MarginRequiredAvailable Node Hose Flow Static Residual Flow Total Demand (gpm)(psi)(psi)(gpm)(psi)(gpm)(psi)(psi)@@Name 1 125.945 52.611 73.3341250.00100.00 125.000126.000 261.90Water Supply Design EngineerJob Number Total Water Required (Including Hose Allowance) 261.90 Maximum Pressure Unbalance In Loops 0.000 Additional Hose Supplies 100.00 Hose Allowance At Source Supplies 203.78gal Light Hazard 0.10gpm/ft² 168ft² 1500ft² (Actual 911ft²) 9 Occupancy Area of Application Coverage Per SprinklerNumber Of Sprinklers Calculated Density Job Suffix Number Of Nozzles Calculated 0 AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area Left: 49.985 Volume capacity of Dry PipesVolume capacity of Wet Pipes Maximum Velocity Under Ground 18.32 between nodes 2 and 3 Maximum Velocity Above Ground 5.6 K-Factor 16.80 at 9.000 Most Demanding Sprinkler Data System Club HouseLa Quinta, CA 92253 Job Site/Building CAL Fire80375 Pomelo Verano Dr. AHJ Mountain View CC Club House Job State Certification/License NumberJob Name: ZACK MCCOY22006 Contractor Contractor Number 1 Name of Contractor: KINCAID INDUSTRIES Address 1 31065 PLANTATION DR Address 2 THOUSAND PALMS, CA 92276 Contact Name Contact Title ExtensionPhone 760-343-5457 FAX 760-343-5446 E-mail INFO@KINCAIDINDUSTRIES.COM Web-Site KINCAIDINDUSTRIES.COM INFO Address 3 LIC# 695797 A, C-36, C-16 Address 1 Address 2 Drawing Name Mountain View TI Plan.cad System Flow Demand 161.90 Remote Area(s) Address 3 6/11/2020© M.E.P.CAD, Inc.Page 2AutoSPRINK 2019 v15.1.20.0 9:53:35AM Hydraulic Graph Report Description: Light Hazard (DA-1) Job Number: 22006 125.000 @ 1250.00 Residual: Pressure 126.000 Static: Pressure Water Supply at Node 1 Hydraulic Graph Water Supply at Node 1 52.611 @ 161.90 52.611 @ 261.90 Available Pressure at Time of Test 125.945 @ 261.90 System Demand System Demand (Including Hose Allowance at Source) © M.E.P.CAD, Inc.6/11/2020 Page 3AutoSPRINK 2019 v15.1.20.0 9:53:35AM FittingsNodeElevation(Foot)Pressure(psi)Discharge(gpm) Node Analysis Report Description: Light Hazard (DA-1) Job Number: 22006 1 0'-0 S 52.611 161.90 101 9'-7 Spr(-13.335)13.335 20.45 102 9'-7 Spr(-10.584)10.584 18.22 103 9'-7 Spr(-9.631)9.631 17.38 104 9'-7 Spr(-9.000)9.000 16.80 105 9'-7 Spr(-9.155)9.155 16.94 106 9'-7 Spr(-12.473)12.473 19.78 107 9'-7 Spr(-10.330)10.330 18.00 108 9'-7 Spr(-9.657)9.657 17.40 109 9'-7 Spr(-9.137)9.137 16.93 2 14'-6 PO(6'-0)35.712 3 14'-6 32.321 4 11'-6 T(5'-0), Tr(1'-0)12.987 5 11'-6 T(5'-0), Tr(1'-0)10.141 6 11'-6 T(5'-0), Tr(1'-0)9.155 7 11'-6 T(5'-0), Tr(1'-0)8.905 8 11'-6 Tr(1'-0), T(6'-0)8.812 9 14'-6 PO(6'-0)35.306 10 14'-6 32.539 11 11'-6 T(5'-0), Tr(1'-0)12.095 12 11'-6 T(5'-0), Tr(1'-0)9.879 13 11'-6 T(5'-0), Tr(1'-0)9.182 14 11'-6 T(6'-0), Tr(1'-0)8.843 91 14'-6 PO(20'-2)38.592 96 14'-6 37.610 © M.E.P.CAD, Inc.6/11/2020 Page 5AutoSPRINK 2019 v15.1.20.0 9:53:37AM FittingsNodeElevation(Foot)Pressure(psi)Discharge(gpm) Node Analysis Report Description: Light Hazard (DA-1) Job Number: 22006 1 0'-0 S 52.611 161.90 101 9'-7 Spr(-13.335)13.335 20.45 102 9'-7 Spr(-10.584)10.584 18.22 103 9'-7 Spr(-9.631)9.631 17.38 104 9'-7 Spr(-9.000)9.000 16.80 105 9'-7 Spr(-9.155)9.155 16.94 106 9'-7 Spr(-12.473)12.473 19.78 107 9'-7 Spr(-10.330)10.330 18.00 108 9'-7 Spr(-9.657)9.657 17.40 109 9'-7 Spr(-9.137)9.137 16.93 2 14'-6 PO(6'-0)35.712 3 14'-6 32.321 4 11'-6 T(5'-0), Tr(1'-0)12.987 5 11'-6 T(5'-0), Tr(1'-0)10.141 6 11'-6 T(5'-0), Tr(1'-0)9.155 7 11'-6 T(5'-0), Tr(1'-0)8.905 8 11'-6 Tr(1'-0), T(6'-0)8.812 9 14'-6 PO(6'-0)35.306 10 14'-6 32.539 11 11'-6 T(5'-0), Tr(1'-0)12.095 12 11'-6 T(5'-0), Tr(1'-0)9.879 13 11'-6 T(5'-0), Tr(1'-0)9.182 14 11'-6 T(6'-0), Tr(1'-0)8.843 91 14'-6 PO(20'-2)38.592 96 14'-6 37.610 © M.E.P.CAD, Inc.6/11/2020 Page 5AutoSPRINK 2019 v15.1.20.0 9:53:37AM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: 22006 Report Description: Light Hazard (DA-1) • • • • • Route 1 • • • • • Pf Pe Pv DR 1.1010 16.80 5.66 0.049282 3'-2 0.745 104 9'-7 16.80 5.6 9.000 12'-0 -0.840 7 11'-6 8.905 15'-2 150 Sprinkler, E(7'-0), T(5'-0) Pf Pe Pv BL 1.3940 29.34 6.17 0.043816 4'-8 0.250 7 11'-6 12.54 8.905 1'-0 6 11'-6 9.155 5'-8 150 Flow (q) from Route 3 Tr(1'-0) Pf Pe Pv BL 1.3940 46.72 9.82 0.103607 8'-6 0.986 6 11'-6 17.38 9.155 1'-0 5 11'-6 10.141 9'-6 150 Flow (q) from Route 4 Tr(1'-0) Pf Pe Pv BL 1.3940 64.94 13.65 0.190518 13'-11 2.846 5 11'-6 18.22 10.141 1'-0 4 11'-6 12.987 14'-11 150 Flow (q) from Route 7 Tr(1'-0) Pf Pe Pv BL 1.3940 85.39 17.95 0.316150 46'-3 20.634 4 11'-6 20.45 12.987 19'-0 -1.301 3 14'-6 32.321 65'-3 150 Flow (q) from Route 9 3Tr(1'-0), 2E(8'-0) Pf Pe Pv BL 1.3800 85.39 18.32 0.501794 0'-9 3.391 3 14'-6 32.321 6'-0 2 14'-6 35.712 6'-9 120 PO(6'-0) Pf Pe Pv CM 2.1570 161.90 14.21 0.186164 10'-2 1.899 2 14'-6 76.51 35.712 96 14'-6 37.610 10'-2 120 Flow (q) from Route 2 Pf Pe Pv CM 3.2600 161.90 6.22 0.024910 12'-6 0.981 96 14'-6 37.610 26'-11 91 14'-6 38.592 39'-5 120 fE(6'-9), PO(20'-2) Pf Pe Pv CM 3.2600 161.90 6.22 0.024910 236'-6 7.733 91 14'-6 38.592 73'-11 6.286 1 0'-0 52.611 310'-5 120 6E(9'-5), fT(17'-6), S 261.90 100.00 Hose Allowance At Source 1 • • • • • Route 2 • • • • • Pf Pe Pv DR 1.1010 16.93 5.70 0.049974 2'-11 0.547 109 9'-7 16.93 5.6 9.137 8'-0 -0.840 14 11'-6 8.843 10'-11 150 Sprinkler, E(7'-0), Tr(1'-0) Pf Pe Pv BL 1.3940 21.33 4.48 0.024291 12'-11 0.339 14 11'-6 4.40 8.843 1'-0 13 11'-6 9.182 13'-11 150 Flow (q) from Route 10 Tr(1'-0) Pf Pe Pv BL 1.3940 38.73 8.14 0.073240 8'-6 0.697 13 11'-6 17.40 9.182 1'-0 12 11'-6 9.879 9'-6 150 Flow (q) from Route 5 Tr(1'-0) Pf Pe Pv BL 1.3940 56.73 11.93 0.148384 13'-11 2.216 12 11'-6 18.00 9.879 1'-0 11 11'-6 12.095 14'-11 150 Flow (q) from Route 6 Tr(1'-0) Pf Pe Pv BL 1.3940 76.51 16.08 0.258036 49'-3 21.744 11 11'-6 19.78 12.095 35'-0 -1.301 10 14'-6 32.539 84'-3 150 Flow (q) from Route 8 3Tr(1'-0), 4E(8'-0) Pf Pe Pv BL 1.3800 76.51 16.41 0.409555 0'-9 2.767 10 14'-6 32.539 6'-0 9 14'-6 35.306 6'-9 120 PO(6'-0) Pf Pe Pv CM 2.1570 76.51 6.72 0.046524 8'-8 0.405 9 14'-6 35.306 2 14'-6 35.712 8'-8 120 • • • • • Route 3 • • • • • Pf Pe Pv DR 1.1010 16.94 5.71 0.050065 2'-11 0.498 105 9'-7 16.94 5.6 9.155 7'-0 -0.840 8 11'-6 8.812 9'-11 150 Sprinkler, E(7'-0) Pf Pe Pv BL 1.3940 12.54 2.64 0.009093 8'-3 0.093 8 11'-6 8.812 2'-0 7 11'-6 8.905 10'-3 150 Tr(1'-0) Tr(1'-0) • • • • • Route 4 • • • • • Pf Pe Pv DR 1.1010 17.38 5.86 0.052470 1'-11 0.364 103 9'-7 17.38 5.6 9.631 5'-0 -0.840 6 11'-6 9.155 6'-11 150 Sprinkler, T(5'-0) • • • • • Route 5 • • • • • Pf Pe Pv DR 1.1010 17.40 5.86 0.052601 1'-11 0.365 108 9'-7 17.40 5.6 9.657 5'-0 -0.840 13 11'-6 9.182 6'-11 150 Sprinkler, T(5'-0) © M.E.P.CAD, Inc.6/11/2020 Page 6AutoSPRINK 2019 v15.1.20.0 9:53:38AM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: 22006 Report Description: Light Hazard (DA-1) • • • • • Route 6 • • • • • Pf Pe Pv DR 1.1010 18.00 6.07 0.055985 1'-11 0.388 107 9'-7 18.00 5.6 10.330 5'-0 -0.840 12 11'-6 9.879 6'-11 150 Sprinkler, T(5'-0) • • • • • Route 7 • • • • • Pf Pe Pv DR 1.1010 18.22 6.14 0.057254 1'-11 0.397 102 9'-7 18.22 5.6 10.584 5'-0 -0.840 5 11'-6 10.141 6'-11 150 Sprinkler, T(5'-0) • • • • • Route 8 • • • • • Pf Pe Pv DR 1.1010 19.78 6.66 0.066648 1'-11 0.462 106 9'-7 19.78 5.6 12.473 5'-0 -0.840 11 11'-6 12.095 6'-11 150 Sprinkler, T(5'-0) • • • • • Route 9 • • • • • Pf Pe Pv DR 1.1010 20.45 6.89 0.070898 1'-11 0.492 101 9'-7 20.45 5.6 13.335 5'-0 -0.840 4 11'-6 12.987 6'-11 150 Sprinkler, T(5'-0) • • • • • Route 10 • • • • • Pf Pe Pv BL 1.3940 4.40 0.93 0.001311 11'-8 0.031 8 11'-6 8.812 12'-0 14 11'-6 8.843 23'-8 150 T(6'-0) T(6'-0) 1.51 4.87 )(150 1.33 140 1.16 130 0.713 100 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc.6/11/2020 Page 7AutoSPRINK 2019 v15.1.20.0 9:53:38AM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: 22006 Report Description: Light Hazard (DA-1) Pipe Type Legend AO Arm-Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Units Legend Diameter Inch Elevation Foot Flow gpm Discharge gpm Velocity fps Pressure psi Length Foot Friction Loss psi/Foot HWC Hazen-Williams Constant Pt Total pressure at a point in a pipe Pn Normal pressure at a point in a pipe Pf Pressure loss due to friction between points Pe Pressure due to elevation difference between indicated points Pv Velocity pressure at a point in a pipe Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap © M.E.P.CAD, Inc.6/11/2020 Page 8AutoSPRINK 2019 v15.1.20.0 9:53:38AM Flow Diagram (Top View) Report Description: Light Hazard (DA-1) Job Number: 22006 © M.E.P.CAD, Inc.6/11/2020 Page 9AutoSPRINK 2019 v15.1.20.0 9:53:39AM Flow Diagram (Isometric View) Report Description: Light Hazard (DA-1) Job Number: 22006 © M.E.P.CAD, Inc.6/11/2020 Page 10AutoSPRINK 2019 v15.1.20.0 9:53:40AM Flow Diagram (Current View) Report Description: Light Hazard (DA-1) Job Number: 22006 © M.E.P.CAD, Inc.6/11/2020 Page 11AutoSPRINK 2019 v15.1.20.0 9:53:41AM Hydraulic Calculator Messages The following list shows notification messages produced by the hydraulic flow calculator while analyzing the system. "Warning" messages indicate unusual conditions that do not prevent the calculation of a hydraulic solution. "Error" messages indicate severe conditions that result in incorrect hydraulic calculations. Report Description: Light Hazard (DA-1) Job Number: 22006 Collecting data... Note: Two pipes abut at 90° without a fitting; calculating as a 90° elbow. (Pipes 22625 & 22754) Note: Pipe ends without a fitting; calculating as if capped. (Node 1366912) Note: Pipe ends without a fitting; calculating as if capped. (Node 1366912) Note: Two pipes abut at 90° without a fitting; calculating as a 90° elbow. (Pipes 22624 & 22625) Note: Two pipes abut at 90° without a fitting; calculating as a 90° elbow. (Pipes 22731 & 22638) Note: Two pipes abut at 90° without a fitting; calculating as a 90° elbow. (Pipes 22732 & 22639) Calculating... © M.E.P.CAD, Inc.6/11/2020 Page 12AutoSPRINK 2019 v15.1.20.0 9:53:41AM Plumbing • Grading • Engineering • Fire Sprinklers 31-065 Plantation Drive • Thousand Palms, CA 92276 • (760) 343-5457 • Fax (760) 343-5446 License # 695797 A, C-36, C-16 • www.KincaidIndustries.com Mountain View Country Club Club House Remodel 80-375 Pomelo Dr La Quinta, CA 92253 Fire Sprinkler Submittal Kincaid Industries, Inc. Project#: 22006 Date: 06-23-2020 Submittal Division: Division 21 By: Zack McCoy The Contractor certifies that we have reviewed the Submittal and have verified the products, field measurements and field construction criteria, and coordination of the information within the submittal with requirements of the work and Contract Documents. Signed: Zack McCoy Plumbing • Grading • Engineering • Fire Sprinklers 31-065 Plantation Drive • Thousand Palms, CA 92276 • (760) 343-5457 • Fax (760) 343-5446 License # 695797 A, C-36, C-16 • www.KincaidIndustries.com Mountain View Country Club Club House Remodel Fire Sprinklers Submittal Table of Contents Division 21 (Design Build) Sprinkler Pipe Bull Moose Sprinkler Pipe Grooved Schedule 10 & 40 Grooved Fittings & Couplings Victaulic FireLock Rigid Coupling Style 009N #10.64 Victaulic FireLock Fittings #10.03 Threaded Fittings Smith-Cooper Ductile Iron Fittings Class 300, Threaded Sprinkler Heads Viking VK462 Concealed Pendent Sprinkler, QR, standard coverage. Viking VK180 Recessed Dry Pendent Sprinkler, QR, standard coverage Victaulic® VicFlex™ Sprinkler Fittings Series AH2 & AH2-CC Braided Flexible Hoses Victaulic® VicFlex™ Sprinkler Fittings Series AH1 & AH1-CC Braided Flexible Hoses Valves NA Hangers & Attachments Tolco B-Line Universal Swivel Sway Fig 980 Tolco B-Line Surge Restrainer Fig 25 Tolco B-Line Trimline Adjustable Band Hanger Fig 200 Tolco B-Line Sway Brace Fig 1001 31-065 Plantation Drive • Thousand Palms, CA 92276 • (760) 343-5457 • Fax (760) 343-5446 License # 695797 A, C-36, C-16 • www.KincaidIndustries.com Hangers & Attachments (cont.) Tolco B-Line Longitudinal In-Line Sway Fig 4LA & 4L Tolco B-Line Fig 77 & 76 Sammy Vertical Mount Wood Screw #GTS30 Sammy Sidewinder Wood Screw #SWG20 Tolco Fig. 23 Hanger for CPVC Plastic Pipe Tolco Fig. 24 Hanger for CPVC Plastic Pipe Tolco Fig. 28M – Offset Hanger and Restrainer for CPVC Plastic Pipe Tolco Fig. 98, 99, & 100 Rod Stiffener Electric NA Sealants Hilti W-L-1392 USG Sheetrock Brad Acoustical Sealant As the leading supplier of steel sprinkler pipe, we understand that there are no second chances in fire suppression. You need products of enduring quality and exceptional strength—plus reliable service. You need Bull Moose. SCHEDULE 10 & 40 ADVANTAGES: • UL listed (US & Canada) and FM approved • ASTM A135 and A795 Type E, Grade A Certified • Complies with NFPA-13, 13R and 14 • Industry-leading hydraulic characteristics • CRR of 1.0 and greater • All pipe NDT weld tested OTHER BENEFITS/SERVICES: • We have the most stocking locations in the industry, for best delivery and availability • Plain end or roll groove • Eddy Guard II™ bacterial-resistant internal coating • Custom length options • Hot dipped galvanization • Reddi-Pipe® red or black pipe eliminates field painting • Compatible for use in wet, dry, preaction and deluge sprinkler systems • The only maker with EPDs (to help earn LEED points). Always ready to protect your most valuable assets. SCHEDULE 10 & 40 Exclusive maker of Reddi-Pipe® RED OR BLACK PAINTED PIPE. 800.325.4467 sales@BullMooseIndustries.com BullMooseTube.com Nominal Pipe Size (Inches)1"1-1/4" 1-1/2"2"2-1/2"3"4"6"8" O.D. (in)1.315 1.660 1.900 2.375 2.875 3.500 4.500 6.625 8.625 I.D. (in)1.097 1.442 1.682 2.157 2.635 3.260 4.260 6.357 8.249 Empty Weight (lb/ft)1.410 1.810 2.090 2.640 3.530 4.340 5.620 9.290 16.940 Water Filled Weight (lb/ft)1.820 2.518 3.053 4.223 5.893 7.957 11.796 23.038 40.086 C.R.R.15.27 9.91 7.76 6.27 4.92 3.54 2.50 1.158 1.805 Pieces per Lift 91 61 61 37 30 19 19 10 7 Lift Weight (lbs) 21' lengths 2,695 2,319 2,677 2,051 2,224 1,732 2,242 1,951 2,490 Lift Weight (lbs) 24' lengths 3,079 2,650 3,060 2,344 2,542 1,979 2,563 2,230 2,848 Lift Weight (lbs) 25' lengths 3,208 2,760 3,187 2,442 2,648 2,062 2,670SCHEDULE 10NPS (In.)1"1-1/4" 1-1/2"2"2-1/2"3"4" 1.315 1.660 1.900 2.375 2.875 3.500 4.500 1.049 1.380 1.610 2.067 2.469 3.068 4.026 1.680 2.270 2.720 3.660 5.800 7.580 10.800 2.055 2.918 3.602 5.114 7.875 10.783 16.316 1.00 1.00 1.00 1.00 1.00 1.00 1.00 70 51 44 30 30 19 19 2,470 2,431 2,513 2,306 3,654 3,024 4,309 2,822 2,778 2,872 2,635 4,176 3,456 4,925 2,940 2,894 2,992 2,745 4,350 3,601 5,130SCHEDULE 40Bull Moose Fire Sprinkler Pipe Product Information Material Specifications: Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Fitting Coating: Orange enamel Red enamel in Europe, Middle East, Africa, and India Optional: Hot dipped galvanized Approvals/Listings: Product Description: FireLock® products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD- developed, hydrodynamic design, affording a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Refer to the appropriate listing agency or approval body for pressure ratings. Pressure ratings vary by agency. FireLock ® Fittings 10.03 1 victaulic.com | FireLock® Fittings | Publication 10.03 10.03 1539 Rev M Updated 12/2014 © 2014 Victaulic Company. All rights reserved. Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date Dimensions: NO. 001 C to E NO. 003 NO. 002 No. 006 Nominal Size Actual Outside Diameter No. 001 90° Elbow No. 003 45° Elbow No. 002 Straight Tee No. 006 Cap C to E Approx. Weight Each C to E Approx. Weight Each C to E Approx. Weight Each C to E Approx. Weight Each inches mm inches mm inches mm Lbs. kg inches mm Lbs. kg inches mm Lbs. kg inches mm Lbs. kg 1 1/4 1.660 ——————0.82 0.3 32 42.4 21 0.1 1 1/2 1.900 ——————0.82 0.4 40 48.3 ——————21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 2 1/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 76.1 mm 3.000 3.00 3.30 2.25 2.4 3.00 3.8 ——76.1 76 1.5 57 1.1 76.2 1.7 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 108 mm 4.250 4.00 5.7 3.00 5.1 4.00 7.5 ——108.0 102 2.6 76 2.3 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 139.7 mm 5.500 4.88 12.4 3.25 8.2 4.88 15.4 ——139.7 124.0 5.6 82.6 3.7 124.0 6.9 159 mm 6.250 5.50 12.6 3.50 9.2 5.50 17.9 ——158.8 140 5.7 89 4.2 140 8.0 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 165.1 mm 6.500 5.43 17.6 3.50 11.4 5.50 22.0 ——165.1 139.7 7.9 88.9 5.2 139.7 9.9 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 C to E C to E T C to E C to E 2 victaulic.com | FireLock® Fittings | Publication 10.03 10.03 1539 Rev M Updated 12/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com Installation Reference should always be made to the I-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic® is a registered trademark of Victaulic Company. Flow Data: Nominal Size Actual Outside Diameter Frictional Resistance Equivalent Feet/meters of Straight Pipe1 Elbows No. 002 Straight Tee inches mm inches mm No. 001 90° Elbow No. 003 45° Elbow Branch Run 1 1/4 1.660 ———— 32 42.4 ———— 1 1/2 1.900 ———— 40 48.3 ———— 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 2 1/2 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 108 mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 139.7 mm 5.500 8.3 4.1 20.6 8.3 139.7 2.5 1.3 6.3 2.5 159 mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 165.1 mm 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 1 The flow data listed is based upon the pressure drop of Schedule 40 pipe. General Notes: NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009N/009H couplings, use FireLock No. 006 end caps containing the “EZ” marking on the inside face or No. 60 end caps containing the “QV EZ” marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. 10.03 1539 Rev M Updated 12/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 3 victaulic.com | FireLock® Fittings | Publication 10.03 victaulic.com | Couplings | FireLock | Rigid | Style 009N | Publication 10.64 10.64 7072 Rev G Updated 10/2014 © 2014 Victaulic Company. All rights reserved. Patented 1.0 CERTIFICATION/LISTINGS C104-1a/36 2.0 PRODUCT DESCRIPTION • The FireLock EZ™ Style 009N Installation-ReadyTM Rigid Coupling is for use in the fire protection market. • The coupling’s unique design eliminates loose parts, promotes consistent installation and provides substantial gains in productivity. • IMPORTANT: FireLock EZ™ Style 009N couplings are recommended for use ONLY on fire protection systems. 3.0 MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) Orange enamel (North America, Asia Pacific) Red enamel (Europe) Hot dipped galvanized Gasket: (specify choice1) Grade “E” EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. 10.64 1 Victaulic® Firelock™ Rigid Coupling Style 009N System No.Location Submitted By Date Spec Section Paragraph Approved Date 10.64 7072 Rev G Updated 10/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 4.0 LISTINGS/APPROVAL 2 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Nominal Size cULus FM Vds LPCB inches mm Sch. 5 psi kPa Sch. 10 psi kPa Sch. 40 psi kPa Sch. 5 psi kPa Sch. 10 psi kPa Sch. 40 psi kPa psi kPa psi kPa 1 1/4 232 365 365 175 363 363 363 363 32 1600 2517 2517 1205 2502 2502 2500 2500 1 1/2 232 365 365 175 363 363 363 363 40 1600 2517 2517 1205 2502 2502 2500 2500 2 363 365 365 175 363 363 363 363 50 2502 2517 2517 1205 2502 2502 2500 2500 2 1/2 N/A 365 365 175 363 363 363 363 65 2517 2517 1205 2502 2502 2500 2500 76.1 mm N/A 365 3 N/A N/A 363 4 N/A 363 363 2517 3 2502 4 2500 2500 3 N/A 365 365 175 363 363 363 363 80 2517 2517 1205 2502 2502 2500 2500 4 N/A 365 365 175 363 363 363 363 100 2517 2517 1205 2502 2502 2500 2500 108.0 mm N/A N/A N/A 175 363 363 N/A N/A120525022502 5 N/A 290 365 N/A 363 363 232 N/A12520002517250225021600 133.0 mm N/A N/A N/A N/A 363 4 N/A N/A N/A2502 4 139.7 mm N/A 290 5 N/A N/A 363 4 N/A 232 N/A2000 5 2502 4 1600 159.0 mm N/A N/A N/A N/A 363 4 N/A N/A N/A2502 4 165.1 mm N/A 290 6 N/A N/A 363 4 N/A N/A N/A2000 6 2502 4 6 N/A 290 365 N/A 363 363 232 N/A15020002517250225021600 216.0 mm N/A N/A N/A N/A 363 4 N/A N/A N/A2502 4 8 N/A 290 365 N/A 363 363 232 N/A20020002517250225021600 2 Listed/Approved for wet and dry pipe systems (> –40°F/–40°C) for continuous use in freezing conditions, use of Style 005H Coupling with Silicone Gasket is recommended. Please see the Victaulic Installation Manual I-009N/009H for details concerning when supplemental lubrication is required. 3 cULus listed for DIN 2458 2.6 mm pipe wall. 4 FM approved for BS 1387 Medium 3.6 mm pipe wall. 5 cULus listed for EN 10220 4.0 mm pipe wall. 6 cULus listed for EN 10255 4.5 mm pipe wall. 2 victaulic.com | Couplings | FireLock | Rigid | Style 009N | Publication 10.64 10.64 7072 Rev G Updated 10/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 4.1 LISTINGS/APPROVAL Speciality Pipe Pipe Size Pressure Rating Pipe Size Pressure Rating Pipe Size Pressure Rating inches cULus psi kPa FM psi kPa inches cULus psi kPa FM psi kPa inches cULus psi kPa FM psi kPa BLT 1 1/4 – 2 300 365 EZT 1 1/4 – 2 300 365 MT 1 1/4 – 2 300 365 2068 2517 2068 2517 2068 2517 DF 1 1/4 – 4 300 365 FF 1 1/4 – 4 300 365 MLT 1 1/4 – 2 N/A 365 2068 2517 2068 2517 2517 DT 1 1/4 – 2 300 365 FLF 1 1/4 – 4 N/A 365 ST 1 1/4 – 2 N/A 365 2068 2517 2517 2517 EF 1 1/4 – 4 175 175 FLT 1 1/4 – 2 N/A 365 STF 1 1/4 – 4 N/A 365 1206 1206 2517 2517 EL 1 1/4 – 2 300 365 FLTL 1 1/4 – 2 N/A 365 TF 2 1/4 – 4 N/A 365 2068 2517 2517 2517 ET40 1 1/4 – 2 300 365 GL 1 1/4 – 2 300 365 WLS 1 1/4 – 2 300 365 2068 2517 2068 2517 2068 2517 EZF 3 – 4 300 365 MF 1 1/4 – 4 300 365 WST 1 1/4 – 2 N/A 365 2068 2517 2068 2517 2517 XL 1 1/4 – 2 300 365 2068 2517 NOTES • BLT = BLT steel pipe manufactured by Allied Tube & Conduit Corp. • DF = DYNA-FLOW steel pipe manufactured by Allied Tube & Conduit Corp. • DT = DYNA-FLOW steel pipe manufactured by Allied Tube & Conduit Corp. • EF = EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • EL = EDDYLITE steel pipe manufactured by Bull Moose Tube Co. • ET40 = Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. • EZF = EZ-Flow steel pipe manufactured by Northwest Pipe Co. • EZT = EZ-Thread steel pipe manufactured by Youngstown Tube Co. • FF = Fire-Flo steel pipe manufactured by Youngstown Tube Co. • FLF = Fire-Line Flow steel pipe manufactured by Western International Forest Products Inc. • FLT = Fire-Line Threadable steel pipe manufactured by Western International Forest Products Inc. • FLTL = Fire-Line Threadable Light steel pipe manufactured by Western International Forest Products Inc. • GL = GL steel pipe manufactured by Wheatland Tube Co. • MF = Mega-Flow steel pipe manufactured by Wheatland Tube Co. • MT = Mega-Thread steel pipe manufactured by Wheatland Tube Co. • MLT = MLT steel pipe manufactured by Wheatland Tube Co • ST = STD wall pipe in accordance with ASTM A53. • STF = Steady Flow steel pipe manufactured by AMS Tube Corp. • TF = Tex-Flow steel pipe manufactured by Tex-Tube Co. • WLS = WLS steel pipe manufactured by Wheatland Tube Co. • WST = WST steel pipe manufactured by Wheatland Tube Company. • XL = XL steel pipe manufactured by Allied Tube & Conduit Corp. 3 victaulic.com | Couplings | FireLock | Rigid | Style 009N | Publication 10.64 10.64 7072 Rev G Updated 10/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 5.0 DIMENSIONS Style 009N Y X Z Y X Z Style 009N Pre-Assembled (Push On Condition)Style 009N Joint Assembled Nominal Size Actual Outside Diameter Maximum Working Pressure 7 Maximum End Load 7 Allow. Pipe End Separation 8 Bolt/Nut 9 Size Dimensions Approx. Weight Each Pre-assembled (Push On Condition)Joint Assembled X Y X Y Z inches mm inches mm psi kPa lbs. N inches mm No. inches mm inches mm inches mm inches mm inches mm inches mm lbs. kg 1 1/4 1.660 365 790 0.10 2 3/8 × 2 M10 x 2 3.13 5.00 2.75 5.00 2.00 1.4 32 42.4 2517 3514 2.54 79 127 70 127 51 0.6 1 1/2 1.900 365 1035 0.10 2 3/8 × 2 M10 x 2 3.38 5.13 3.00 5.13 2.00 1.5 40 48.3 2517 4604 2.54 86 130 76 130 51 0.7 2 2.375 365 1616 0.12 2 3/8 ×2 1/2 M10 x 2 1/2 4.00 5.63 3.50 5.63 2.00 1.9 50 60.3 2517 7193 3.05 102 143 89 143 51 0.9 2 1/2 2.875 365 2370 0.12 2 3/8 × 2 1/2 M10 x 2 1/2 4.50 6.13 4.00 6.13 2.00 2.1 65 73.0 2517 10542 3.05 114 156 102 156 51 1.0 76.1 mm 3.000 365 2580 0.12 2 3/8 × 2 1/2 M10 x 2 1/2 4.63 6.00 4.13 6.13 2.00 2.1 76.1 2517 11476 3.05 118 152 105 156 51 1.0 3 3.500 365 3512 0.12 2 3/8 × 2 1/2 M10 x 2 1/2 5.13 6.75 4.63 6.75 2.00 2.3 80 88.9 2517 15622 3.05 130 171 117 171 51 1.0 4 4.500 365 5805 0.17 2 3/8 × 2 1/2 M10 x 2 1/2 6.00 7.88 5.63 7.50 2.13 2.9 100 114.3 2517 25822 4.32 152 200 143 191 54 1.3 108.0 mm 4.250 365 5175 0.17 2 3/8 × 2 1/2 M10 x 2 1/2 5.63 7.38 5.38 7.38 2.13 3.1 108.0 2517 23020 4.32 152 1.87 137 187 54 1.4 5 5.563 365 8870 0.17 2 1/2 × 3 M12 x 3 7.25 9.25 6.75 9.13 2.25 5.0 125 141.3 2000 39456 4.32 184 235 171 232 57 2.3 133.0 mm 5.250 365 7897 0.17 2 1/2 × 3 M12 x 3 6.63 9.00 6.38 9.00 2.25 4.8 133.0 2517 35106 4.32 168 229 162 229 57 2.2 139.7 mm 5.500 365 8667 0.17 2 1/2 × 3 M12 x 3 6.88 9.25 6.75 9.13 2.25 4.9 139.7 2517 38529 4.32 175 235 171 232 57 2.2 159.0 mm 6.250 365 11192 0.17 2 1/2 × 3 1/4 M12 x 3 1/4 7.88 10.00 7.38 9.88 2.25 5.6 159.0 2517 49753 4.32 200 254 187 251 57 2.5 165.1 mm 6.500 365 12105 0.17 2 1/2 × 3 1/4 M12 x 3 1/4 8.00 10.25 7.75 10.13 2.25 6.0 165.1 2517 53813 4.32 203 260 197 257 57 2.7 6 6.625 365 12582 0.17 2 1/2 × 3 1/4 M12 x 3 1/4 8.38 10.38 7.88 10.13 2.25 6.0 150 168.3 2000 44469 4.32 213 264 200 257 57 2.7 216.0 mm 8.500 365 20712 0.17 2 5/8 × 4 M16 x 4 10.63 13.25 10.25 10.13 2.63 11.4 216.0 2517 55968 4.32 270 337 260 257 67 5.2 8 8.625 365 21326 0.17 2 5/8 × 4 M16 x 4 10.88 13.38 10.25 13.13 2.50 11.4 200 219.1 1620 94863 4.32 276 340 260 333 64 5.2 7 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See the Listings/Approvals section of this publication for ratings on other pipe. 8 The allowable pipe separation dimension shown is for system layout purposes only. FireLock EZ™ couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. 9 Number of bolts required equals number of housing segments. NOTES • When assembling FireLock EZ™ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ™ Style 009N couplings, use FireLock No. 006 end caps containing the “EZ” marking on the inside face or No. 60 end caps containing the “QV EZ” marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009N couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N coupling. There is no interchanging of gaskets or housings between coupling styles. • Use Of Flushseal Gaskets For Dry Pipe Systems FireLock EZ™ couplings are supplied with FireLock EZ™ Grade “E” Type A gaskets. These gaskets include an integral pipe stop, that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard Victaulic Flush-Seal™ gaskets are not compatible and cannot be used with the FireLock EZ™ couplings. 4 victaulic.com | Couplings | FireLock | Rigid | Style 009N | Publication 10.64 10.64 7072 Rev G Updated 10/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms “Patented” or “Patent Pending” refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the I-009N/I-009H Firelock EZ Rigid Coupling Installation Instructions for the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic, FireLock EZ™, Flush-Seal™, and Installation-Ready™ are trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/ or other countries. 6.0 REFERENCE MATERIALS Publication 05.01: Seal Selection Guide I-009N/009H: Installation Instructions FireLock EZ™ Rigid Coupling 5 victaulic.com | Couplings | FireLock | Rigid | Style 009N | Publication 10.64 Ductile Iron Threaded Fittings Ductile Iron Threaded Fittings Ductile Iron Threaded Fittings TemperatureDegrees F Working Pressure, Non-Shock psigClass 300 Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 Specifications • branded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 psi WSP • Ductile iron castings conform to ASTM A536 • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 • All fittings are 100% air tested • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical & mechanical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 • ProPak™ Packaging SCI ProPak™ System SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com201 DUCTILE A A A A A A AA B Size in Part Number A in Packing Weight lbInnerMaster 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 1 35E 3010 1.50 40 80 0.5 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Size in Part Number A in B in Packing Weight lbInnerMaster 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 1-1/2 35F 3014 1.44 20 40 1.0 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35T 3004 1.13 80 160 0.3 3/4 35T 3006 1.31 30 60 0.5 1 35T 3010 1.50 25 50 0.7 1-1/4 35T 3012 1.75 10 20 1.1 1-1/2 35T 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 Fig. 35E 3 – 90° Elbow Fig. 35RE3 – 90° Reducing Elbow Fig. 35F 3 – 45° Elbow Fig. 35T 3 – Tee Ductile Iron Threaded Fittings - Class 300 UL/FM SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 202 DUCTILE A B AB C C Size in Part Number A in B in C in Packing Weight lbInnerMaster 3/4 x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 1 x 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 1 x 1/2 x 1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1 x 3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 1 x 3/4 x 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 1 x 3/4 x 1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4 x 3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2 x 3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2 x 3/4 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2 x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2 x 1 x 1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2 x 1 x 3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2 x 1 x 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1/2 x 1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2 x 1-1/4 x 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2 x 1-1/4 x 1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2 x 1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2 x 1-1/2 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2 x 1-1/2 x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 Size in Part Number A in B in C in Packing Weight lbInnerMaster 3/4 x 1 35BT3006010 1.45 1.45 1.37 30 60 0.6 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 1 x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 1-1/4 x 1 x 1-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1.2 1-1/4 x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2 x 2 35BT3014020 2.16 2.16 2.02 8 16 1.8 Fig. 35BT3 – Bull Head Tee Fig. 35RT3 – Reducing Tee Ductile Iron Threaded Fittings - Class 300 UL/FM SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com203 DUCTILE A A A AA B Size in Part Number A in Packing Weight lbInnerMaster 1 35U 3010 2.19 20 40 1.0 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 3.12 6 12 2.4 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Size in Part Number A in Packing Weight lbInnerMaster 1 x 1/2 35RC3010004 1.69 80 160 0.3 1 x 3/4 35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (not hex)35RC3020010 2.81 20 40 1.0 Size in Part Number A in B in Packing Weight lbInnerMaster 1 x 1/2 35HB3010004 1.06 1.40 180 360 0.2 1 x 3/4 35HB3010006 1.06 1.40 180 360 0.1 1-1/4 x 1 35HB3012010 1.19 1.80 90 180 0.2 1-1/2 x 1 35HB3014010 1.25 1.95 75 150 0.4 1-1/2 x 1-1/4 35HB3014012 1.25 1.95 75 150 0.3 2 x 1 35HB3020010 1.38 2.55 40 80 0.6 2 x 1-1/4 35HB3020012 1.38 2.55 40 80 0.6 2 x 1-1/2 35HB3020014 1.38 2.55 40 80 0.6 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35CP3 – Straight Coupling with Ribs Fig. 35RC3 – Hex Reducing Coupling Fig. 35HB3 – Hex Bushing Fig. 35SP3 – Square Head Plug Fig. 35U 3 – Union with Brass Seat Ductile Iron Threaded Fittings - Class 300 UL/FM SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 204 DUCTILE A A A A A A A B B Size in Part Number A in B in Packing Weight lbInnerMaster 1-1/4 x 1 35RX3012010 1.67 1.58 15 30 1.2 1-1/2 x 1 35RX3014010 1.80 1.65 12 24 1.4 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 Size in Part Number A in Packing Weight lbInnerMaster 1 35X 3010 1.50 20 40 0.9 1-1/4 35X 3012 1.75 12 24 1.4 1-1/2 35X 3014 1.94 8 16 1.8 2 35X 3020 2.25 6 12 2.8 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35C 3004 0.87 300 600 0.1 3/4 35C 3006 0.97 200 400 0.1 1 35C 3010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35X 3 – Cross Fig. 35RX3 – Reducing Cross Fig. 35C 3 – Cap Size in Part Number A in Packing Weight lbInnerMaster 3/8 35BC3003 0.75 100 200 0.3 1/2 35BC3004 0.75 80 160 0.5 Fig. 35BC3 – Beam Clamp A Ductile Iron Threaded Fittings - Class 300 UL/FM MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.02.19 Rev 20.2 Page 1 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTIONViking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired.The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile cover assembly that provides up to ½” (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “push-on”, “thread-off” design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive environments and is listed and approved as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 VdS Approved: Certificate G4080021 LPCB Approved: Ref. No. 096e/12 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032 China Approval: Approved according to China GB Standard Refer to the Approval Charts and Design Criteria listing and approval requirements that must be followed. 3. TECHNICAL DATA Specifications:Available since 2006.Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating “250” stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar)Thread size: 1/2” (15 mm) NPTNominal K-Factor: 5.6 U.S. (80.6 metric**)Glass-bulb fluid temperature rated to -65°F (-55°C)Patents Pending * cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). ** Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards:Sprinkler Body: Brass UNS-C84400Deflector: Copper UNS-C19500 for Sprinkler; Phosphor Bronze UNS-C51000 for Sprinkler VK463Deflector Pins: Stainless Steel AlloyBulb: Glass, nominal 3 mm diameterPip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400Button: Brass UNS-C36000 Screws: 18-8 Stainless SteelBelleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon TapeYoke: Phosphor Bronze UNS-C51000Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials:Cover: Copper UNS-C11000 or Stainless Steel UNS-S30400Base: Brass UNS-C26000 or UNS-C26800Springs: Nickel AlloySolder: Eutectic Ordering Information: The sprinkler and cover plate must be ordered separately. Refer to Tables 1 and 2. Replaces Form No. F_103005 Rev 20.1 (Revised approval specifications for 21356A.) MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.02.19 Rev 20.2 Page 2 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 4. INSTALLATIONRefer to appropriate NFPA Installation Standards. 5. OPERATIONDuring fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCERefer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITYViking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEEFor details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: SPRINKLER ORDERING INFORMATION Instructions: Using the sprinkler base part number, (1) add the suffix for the desired Finish (2) add the suffix for the desired Temperature Rating. (3) Select a cover plate (See Table 2) SIN Sprinkler Base Part Number8 Size 1: Finishes 2: Temperature Ratings NPT Inch BSPT mm Description Suffix1 Sprinkler Temperature Classification Nominal Rating Bulb Color Max. Ambient Ceiling Temperature2 Suffix VK462 13503 1/2 --Brass A Oridinary 155 °F (68 °C)Red 100 °F (38 °C)B VK462 213567,9 --15 ENT 3,4 JN Intermediate 175 °F (79 °C)Yellow 150 °F (65 °C)D VK463 13667 1/2 --Intermediate 200 °F (93 °C)Green 150 °F (65 °C)E Example:13503AE = 200 °F (93 °C) Temperature Rated Sprinkler with a standard Brass finish. Accessories Sprinkler Wrenches and tools (see Figure 1): A. Heavy Duty Part Number: 14047W/B5 (available since 2006) B. Head Cabinet Wrench Part Number: 140316 (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part Number: 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) Sprinkler Cabinet:Holds up to 6 sprinklers: Part number 01731A (available since 1971). Footnotes 1. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. 2. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. UL Listed as corrosion resistant. 4. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. 5. Requires a ½” ratchet (not available from Viking). 6. Also optional for removal of the protective cap. Ideal for sprinkler cabinets. 7. Not available with ENT finish. See approval charts for more information. 8. See approval charts for more information. 9. Approved according to China GB Standard. MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.02.19 Rev 20.2 Page 3 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Figure 1: Identification of Custom Paint for Concealed Covers Figure 2: Square Cover Assembly 3-5/16” (84 mm) TABLE 2: COVER PLATE ORDERING INFORMATION Instructions: Using the cover plate base part number, (1) add the suffix for the desired Finish (2) add the suffix for the required Cover Plate Nominal Rating. Cover Plate Base Part Number3 Size Inch (mm)Style 1: Finishes Temperature Rating Matrix1,2 Description Suffix5 Cover Plate Nominal Rating (Required) Sprinkler Nominal Rating / Temperature Classification Sprinkler Max. Ambient Ceiling Temperature2 Suffix 23190 2-3/4 (70)Round Polished Chrome F 135 °F (57 °C) UL 155 °F (68 °C) / ORD 100 °F (38 °C)A231743-5/16 (84)Round Brushed Chrome F-/B 139 °F (59 °C) FM 23179 3-5/16 (84)Square Bright Brass B 165 °F (74 °C)175 °F (79 °C) / INT 150 °F (65 °C)C 231934 2-3/4 (70)SST Antique Brass B-/A 165 °F (74 °C)200 °F (93 °C) / INT 150 °F (65 °C)C 231834 3-5/16 (84)SST Brushed Brass B-/B Example: 23190MC/W = 165 °F (74 °C) Temperature Rated 2-3/4” (70 mm) Diameter Round Cover Plate with a Painted White finish. Brushed Copper E-/B Painted White M-/W Painted Ivory M-/I Painted Black M-/B Footnotes 1. The sprinkler temperature rating is stamped on the deflector. 2. Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 4. Stainless Steel versions are not available with any finishes or paint. 5. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label.FACTORY APPLIE D C USTO M P A I NT COLOR MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.02.19 Rev 20.2 Page 4 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart 1 (UL) Mirage® Concealed Pendent Sprinklers VK462 and VK463 Sprinkler Base Part No.1 SIN Thread Size Nominal K-factor Maximum Water Working Pressure Listings and Approvals4 (Refer also to Design Criteria) NPT Inch BSPT mm U.S.metric2 cULus5 NYC VdS7 LPCB China Approval Standard Response Applications 13503A VK462 1/2”--5.6 80.6 175 psi (12 bar)----AY1, CZ1 AY1, BZ1 AY1, CZ18 -- 21356A12 VK462 --15 5.6 80.6 175 psi (12 bar)----------AY1, CZ1 Quick Response Applications 13503A VK462 1/2”15 5.6 80.6 175 psi (12 bar)AV1, BX1, AS2, BT2 AV1, BX16 -------- 13503JN11 VK462 1/2”15 5.6 80.6 175 psi (12 bar)AV1, BX1, AS2, BT2 AV1, BX16 -------- 21356A12 VK462 --15 5.6 80.6 175 psi (12 bar)AY1, CZ1 ---------- 13667A VK463 1/2”15 5.6 80.6 250 psi (17.2 bar)3 AV1, BX1 AV1, BX16 -------- 13667JN11 VK463 1/2”15 5.6 80.6 250 psi (17.2 bar)3 AV1, BX1 AV1, BX16 -------- Approved Sprinkler Temperature Rating Codes Approved Cover Plate Temperature Rating Codes Approved Cover Plate Finish Codes A = 155 °F (68 °C) B = 175 °F (79 °C) C = 200 °F (93 °C) S - 135 °F (57 °C) cover 23193 or 23183 (large diameter) T - 165 °F (74 °C) cover 23193 or 23183 (large diameter) V - 135 °F (57 °C) cULus Listed cover 23190, 23174 (large diameter), or 23179 (square cover plate) X - 165 °F (74 °C) cover 23190, or 23174 (large diameter) Y - 135 °F (57 °C) cover 23190 LPCB Approved as 139 °F (59 °C) Z - 165 °F (74 °C) cover 23190 1 - Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 2 - Stainless Steel Footnotes 1. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. The Water Working Pressure rating is stamped on the deflector. 4. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5. Listed by Underwriter’s Laboratories for use in the U.S. and Canada. 6. Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. 7. VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999 + A1:2001 + A2:2004 + A3:2006, Certificate G4080021. 8. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. 9. The 135/139 °F cover has an orange label. The 165 °F (74 °C) cover has a white label. 10. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. 11. cULus Listed as corrosion resistant. 12. Approved according to China GB Standard. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.02.19 Rev 20.2 Page 5 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA - UL (Also refer to Approval Chart 1) cULus Listing Requirements: Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. • For hazard occupancies up to and including Ordinary Hazard, Group II. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). • Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. • Minimum distance from walls is 4 in. (102 mm). • Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. • The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS Approval Requirements: a) The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. b) This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. c) Follow installation guidelines of current standards, CEA4001VdS and EN12845. These sprinklers can only be installed in LH and OH occupan- cies, except in OH4. NOTES: Due to the design the sprinkler type ‘Domed-CCP’ shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type ‘Domed-CCP’ shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: 1. Prepare the sprinkler key. 2. Remove the plastic cover. 3. Hold the sprinkler with the wrench and fasten it. 4. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.02.19 Rev 20.2 Page 6 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Approval Chart 2 (FM) Mirage® Standard Response Concealed Pendent Sprinkler VK462 Sprinkler Base Part No.1 SIN Thread Size Nominal K-Factor Maximum Water Working Pressure FM Approvals3 (Refer also to Design Criteria below.)NPT Inch BSPT mm U.S.metric2 13503A VK462 1/2”15 5.6 80.6 175 psi (12 bar)AW1, BX1, AY2, BZ2 21356A6 VK462 --15 5.6 80.6 175 psi (12 bar)AU1, CV1 Approved Sprinkler Temperature Rating Codes Approved Cover Plate Temperature Rating Codes Approved Cover Plate Finish Codes A - 155 °F (68 °C) B - 175 °F (79 °C) and 200 °F (93 °C) C - 200 °F (93 °C) U - 139 °F (59 °C) cover 23190 V - 165 °F (74 °C) cover 23190 W - 139 °F (59 °C) cover 23190, 23174 (large diameter), or 23179 (square cover plate) X - 165 °F (74 °C) cover 23190, 23174 (large diameter), or 23179 (square cover plate) Y - 139 °F (59 °C) cover, 23183 or 23193 Z - 165 °F (74 °C) cover 23183 or 23193 1 - Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 2 - Stainless Steel Footnotes 1. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4. The 139 °F (59 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. 5. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. 6. Approved according to China GB Standard. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.02.19 Rev 20.2 Page 7 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins Sprinkler Wrench Part No. 14047W/B** ** A 1/2” ratchet is required (Not available from Viking) 2-1/4” (57 mm) diameter opening required in the ceiling. Step 2: Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Figure 3: Sprinkler Installation and Proper Wrench Usage NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Sprinkler wrench flat Sprinkler frame arms Figure 4: Sprinkler Dimensions and Cover Installation 1/2” (15 mm) NPT 2-3/16”(55 mm)2-9/16” (65 mm) Maximum 2-1/16” (52 mm) Minimum 2-3/4” (70 mm) or 3-5/16” (84 mm)NOTE: Upon sprinkler activation, the deflector descends to approximately 13/16” (21 mm) below the sprinkler body. Replaces Form No. F_103005 Rev 20.1 (Revised approval specifications for 21356A.) QUICK RESPONSE DRY PENDENT SPRINKLERSTECHNICAL DATA Form No. F_031793 19.10.14 Rev 19.2 Page 1 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION Viking Quick Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry sys- tems and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Quick Response Dry Pendent Sprinklers are available in various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global has no approval classification for Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2013 and 2015 NYC Approved: MEA 89-92-E Volume 15 Refer to Approval Chart 1 and Design Criteria on page 105d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 105e for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1” NPT or 25 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric*) for all listed and approved lengths. * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Covered by the following U.S. Patents: 8,636,075 and 10,220,231 Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Pip Cap: Brass UNS-C31400 or UNS-C31600 Pip Cap Adapter: Brass UNS-C36000 Orifice: Copper UNS-C22000 or UNS-C11000 Tube: ERW Hydraulic Steel Tube Support (Internal): Stainless Steel UNS-S30400 Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Barrel End and Threads: QM Brass Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 ENT Coated Adjustable and Recessed Escutcheons: Stainless Steel UNS-S30400 Ordering Information: (Also refer to the current Viking price list.) Replaces Form F_031793 Rev. 19.1 (Added ENT; updated FM language.) QUICK RESPONSE DRY PENDENT SPRINKLERSTECHNICAL DATA Form No. F_031793 19.10.14 Rev 19.2 Page 2 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Order Quick Response Dry Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating, and then the suffix for the length (“A” dimension) to sprinkler base part number. Order in a specific length noted as the “A” dimension. The “A” dimension is the distance from the face of the fitting (tee) to the desired finished surface of the ceiling. These sprinklers are listed and approved in lengths from 1-1/2” to 45-1/2” (38.1 mm to 1,156 mm) for the adjustable standard style, 3” to 47” (76.2 mm to 1,194 mm) for the plain barrel style, and 3-1/4” to 47-1/2” (82.5 mm to 1,207 mm) for the adjustable recessed style. Lengths exceeding the standard lengths are available, with no approvals, on a “made-to-order” basis: Recessed Dry Pendent up to 65-1/2” (1,664 mm). Adjustable Standard Dry Pendent up to 63-1/2” (1,613 mm). Plain Barrel Dry Pendent up to 65” (1,651 mm). Contact the manufacturer for more information. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G For example, sprinkler VK176 with a Chrome finish and a 155 °F (68 °C) temperature rating, and “A” length of 10” = Part No. 08383UFB10. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the “Sprinkler Accessories” section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 07297W/B (available since 1991) B. Wrench for recessed sprinklers: Part No. 07565W/B** (available since 1991) **A ½” ratchet is required (not available from Viking). Sprinkler Guard: Chrome, with no listings or approvals, for installation on dry pendent sprinklers made after May 1994 only (Part No. 08954). Replacement Escutcheons: A. Adjustable Standard Dry Escutcheon: Base Part No. 07741 B. Recessed Dry Escutcheon Cup: Base Part No. 05459A 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the internal parts to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS & MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Quick Response Dry Pendent Sprink- ler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 07297W/B Figure 2: Wrench 07565W/B for Adjustable Recessed Dry Pendent Sprinklers QUICK RESPONSE DRY PENDENT SPRINKLERSTECHNICAL DATA Form No. F_031793 19.10.14 Rev 19.2 Page 3 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 155 °F (68 °C)100 °F (38 °C)Red Intermediate 175 °F (79 °C)150 °F (65 °C)Yellow Intermediate 200 °F (93 °C)150 °F (65 °C)Green High 286 °F (141 °C)225 °F (107 °C)Blue Sprinkler Finishes: Brass, Chrome, White Polyester, and ENT Corrosion-Resistant Coating3,4: White Polyester and ENT in all temperature ratings Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Note: These coatings are NOT cor- rosion proof. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environ- ment. Polyester and ENT coatings are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. 4 When installed in some corrosive environments, the Polyester finish may change color. This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. Figure 3: Adjustable Standard Dry Pendent Sprinkler QUICK RESPONSE DRY PENDENT SPRINKLERSTECHNICAL DATA Form No. F_031793 19.10.14 Rev 19.2 Page 4 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 1 (UL) Quick Response Dry Pendent Sprinklers Maximum 175 PSI (12 bar) WWP Sprinkler Base Part No.1 SIN Style Thread Size Nominal K-Factor2 Order Length Increment Listings and Approvals4 (Refer also to Design Criteria below.) NPT BSP U.S.metric3 Inches mm cULus5 NYC6 VdS LPCB 08383U VK176 Adjustable Standard 1”--5.6 80.6 1/2”12.7 A1, A5 A1 -------- 16457U --25 mm --80.6 1/2”12.7 A1, A5 ---------- 08385U VK180 Adjustable Recessed 1”--5.6 80.6 1/4”6.35 B2, B6 B2 -------- 16453U --25 mm --80.6 1/4”6.35 B2, B6 ---------- 08387U VK172 Plain Barrel 1”--5.6 80.6 1/2”12.7 A3 A4 -------- 16455U --25 mm --80.6 1/2”12.7 A3 ---------- Approved Temperature Ratings A - 155 °F (68 °C), 175 °F (79°C), 200 °F (93 °C), and 286 °F (141 °C) B - 155 °F (68 °C), 175 °F (79°C), and 200 °F (93 °C) Approved Finishes and “A” Dimensions 1 - Chrome or White Polyester7 sprinkler with a Chrome or White Polyester Sleeve and Escutcheon with “A” dimensions 1-1/2” to 45-1/2” (38.1 mm to 1,156 mm) 2 - Chrome or White Polyester7 with “A” dimensions 3-1/4” to 47-1/2” (82.5 mm to 1,207 mm) 3 - Chrome, Brass, White Polyester7, or ENT 7 with “A” dimensions 3” to 47” (76.2 mm to 1,194 mm) 4 - Chrome or Brass with “A” dimensions 3” to 47” (76.2 mm to 1,194 mm) 5 - ENT7 sprinkler with an ENT7 Sleeve and Escutcheon with “A” dimensions 1-1/2” to 45-1/2” (38.1 mm to 1,156 mm) 6 - ENT7 with “A” dimensions 3-1/4” to 47-1/2” (82.5 mm to 1,207 mm) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths (“A” Dimensions indicated above). 3 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 4 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5 Listed by Underwriter’s Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 15. 7 cULus Listed as corrosion resistant. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-Bl tees. When selecting other CPVC fittings, contact Viking Technical Services. cULus Listing Requirements: Standard Dry Pendent Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. QUICK RESPONSE DRY PENDENT SPRINKLERSTECHNICAL DATA Form No. F_031793 19.10.14 Rev 19.2 Page 5 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.comApproval Chart 2 (FM) Quick Response Dry Pendent Sprinklers Maximum 175 PSI (12 bar) WWP Sprinkler Base Part No.1 SIN Style Thread Size Nominal K-Factor2 Order Length Increment FM Approvals4 (Refer also to Design Criteria below.)NPT BSP U.S.metric3 Inches mm 08383U VK176 Adjustable Standard 1”--5.6 80.6 1/2”12.7 A1 16457U --25 mm --80.6 1/2”12.7 A1 08385U VK180 Adjustable Recessed 1”--5.6 80.6 1/4”6.35 B2 16453U --25 mm --80.6 1/4”6.35 B2 08387U VK172 Plain Barrel 1”--5.6 80.6 1/2”12.7 A3 16455U --25 mm --80.6 1/2”12.7 A3 Approved Temperature Ratings A - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141 °C) B - 155 °F (68 °C), 175 °F (79°C), and 200 °F (93 °C) Approved Finishes and “A” Dimensions 1 - Brass, Chrome, White Polyester, or ENT5 sprinkler with a Brass, Chrome, White Polyester, or ENT5 Sleeve and Escutcheon with “A” dimensions 1-1/2” to 45-1/2” (38.1 mm to 1,156 mm) 2 - Brass, Chrome, White Polyester, or ENT5 with “A” dimensions 3-1/4” to 47-1/2” (82.5 mm to 1,207 mm) 3 - Brass, Chrome, White Polyester, or ENT5 with “A” dimensions 3” to 47” (76.2 mm to 1,194 mm) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths (“A” Dimensions indicated above). 3 Metric K-Factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 4 This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any ad-ditional approvals. 5 FM approved as corrosion resistant. Figure 4: Adjustable Recessed Dry Pendent Sprinkler Figure 5: Plain Barrel Dry Pendent Sprinkler DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-Bl tees. When selecting other CPVC fittings, contact Viking Technical Services. FM Approval Requirements: The Dry Pendent Sprinklers in the Approval Chart above are FM Approved as quick response Non-storage standard spray sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (includ-ing 2-0) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. QUICK RESPONSE DRY PENDENT SPRINKLERSTECHNICAL DATA Form No. F_031793 19.10.14 Rev 19.2 Page 6 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Figure 6: Dry Pendent Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry Pendent Sprinkler is Shown) Figure 7: Dry Sprinkler Seal (Adjustable Standard Dry Pendent Sprinkler is Shown) Replaces Form F_031793 Rev. 19.1 (Added ENT; updated FM language.) victaulic.com 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. Series AH1 Series AH1-CC 1.0 PRODUCT DESCRIPTION Available Sizes by Component • Series AH1 0.8"/DN20 Nominal ID Braided Hose: 31, 36, 48, 60, 72"/790, 914, 1220, 1525, 1830 mm. Note: length includes adapter nipple and 5.75"/140 mm straight reducer. • Series AH1-CC 0.8"/DN20 Nominal ID Braided Hose: 31, 36, 48, 60, 72"/790, 914, 1219, 1525, 1830 mm. Note: length includes captured coupling and 5.75"/140 mm straight reducer. • Sprinkler Reducers: • Sprinkler Connections: ½ and ¾"/15 and 20mm • Straight Lengths: 5.75, 9, 13"/140, 230, 330 mm • 90º Elbows: • Short (typically used with concealed sprinklers) • Long (typically used with recessed pendent sprinklers) • Low Profile Short (for use with Style AB5, AB11, AB12, ABBA and ABMM Bracket) • Low Profile Long (for use with Style AB5, AB11, AB12, ABBA and ABMM Bracket) • Inlet Connections: • 1"/25 mm Grooved IGS • 1"/25 mm NPT or BSPT adapter nipples for attaching to pipe and fittings outlined in NFPA standards. • ¾"/20 mm NPT or BSPT adapter nipples available for VdS. • 1 ¼"/32mm BSPT adapter nipples available for LPCB. Victaulic® VicFlex™ Sprinkler Fittings Series AH1 and AH1-CC Braided Flexible Hose 10.95 1 System No.Location Submitted By Date Spec Section Paragraph Approved Date 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 1.0 PRODUCT DESCRIPTION (Continued) • Brackets: • Style AB1 for suspended and hard-lid ceilings, allows installation before most ceiling tiles in place • Style AB2 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place • Style AB3 for surface mount applications, wood, metal and block walls or ceilings • Style AB4 for hard-lid ceilings with hat furr ing channel grid systems, allows for vertical sprinkler adjustment • Style AB5 for hard-lid ceilings, allows for vertical sprinkler adjustment • Style AB7 for suspended and hard-lid ceilings • Style AB7 Adjustable for suspended and hard-lid ceilings • Style AB8 for hard-lid ceilings with CD 60/27 profile metal studs (regionally available) • Style AB10 for Armstrong® TechZone™ ceilings • Style AB11 for lay-in panel suspended t-grid ceilings or drywall suspended t-grid ceilings, allows for low profile installations (use only with 90° low profile elbows) • Style AB12 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and allows for low profile installation down to 4"/100mm • Style ABBA bracket for suspended, exposed, and hard-lid ceilings • Style ABMM bracket for surface mount and stand off-mount applications, wood, metal and block walls, or ceilings and hard-lid ceilings Maximum Working Temperature • 225°F/107°C Maximum Working Pressure • 200 psi/1375 kPa (FM Approval) • 175 psi/1206 kPa (cULus Listed) • 1600 kPa/232 psi (VdS/LPCB Approved) • 1.4 MPa (CCC Approval) Connections • To adapter nipple (inlet) via • 1"/25.4 mm Grooved IGS • 1"/25.4 mm NPT or BSPT male thread • ¾"/20 mm BSPT male thread (VdS only) • 1 ¼"/32 mm BSPT male thread (LPCB only) • To sprinkler head (outlet) via ½" or ¾"/15 mm or 20 mm Minimum Bend Radius • 7"/178 mm (FM/CCC Approval) • 3"/76.2 mm (cULus Listed) • 3"/76.2 mm (VdS/LPCB Approved) Maximum Allowable Sprinkler K-Factors • FM (½"/15mm reducer) K5.6/8,1 (S.I.), (¾"/20mm reducer) K14.0/20,2 (S.I.) • cULus (½"/15mm reducer) K8.0/11,5 (S.I.), (¾"/20mm reducer) K14.0/20,2 (S.I.) • VdS/LPCB (½"/15mm reducer) K5.6/8,1 (S.I.), (¾"/20mm reducer) K8.0/11,5 (S.I.) 2 victaulic.com 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 3 victaulic.com 2.0 CERTIFICATION/LISTINGS 3.0 SPECIFICATIONS – MATERIAL Series AH1 • Flexible Hose: 300-series Stainless Steel • Collar/Weld Fitting: 300-series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (½ or ¾"): Carbon Steel, Zinc-Plated Brackets: Carbon Steel, Zinc-Plated Series AH1-CC • Flexible Hose: 300-series Stainless Steel • Collar/Weld Fitting: 300-series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Coupling Retainer Ring: Polyethelene • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (½"/15 mm or ¾"/20 mm): Carbon Steel, Zinc-Plated • Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Coupling Housing Coating: • Orange enamel (North America, Asia Pacific). • Red enamel (Europe). • Hot dipped galvanized. Gasket:1 • Grade “E” EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. • Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. • Linkage: CrMo Alloy Steel zinc electroplated per ASTM B633 Zn/Fe 5, Type III Finish. 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 4 victaulic.com 4.0 DIMENSIONS Product Details - Series AH1 Braided Hose BA 371 2 465 Item Description 1 Flexible Hose 2 Isolation Ring 3 Gasket 4 Nut 5 Branch Line Nipple 6 Braid 7 Collar/Weld Fitting Hose Length Dimensions Hose Length A B inches mm inches mm inches mm 31/790 25.25/641 31/790 36/915 31.25/794 36/915 48/1220 42.25/1073 48/1220 60/1525 54.25/1378 60/1525 72/1830 66.25/1683 72/1830 Series AH1-CC BA 3712 46 5 Item Description 1 Flexible Hose 2 Isolation Ring 3 Gasket 4 Nut 5 Style 108 Coupling 6 Braid 7 Collar/Weld Fitting Hose Length Dimensions Hose Length A B inches mm inches mm inches mm 31/790 24.5/622 29.8/757 36/915 29.5/749 34.8/884 48/1220 41.5/1054 46.8/1189 60/1525 53.5/1359 58.8/1494 72/1830 65.5/1664 70.8/1798 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5 victaulic.com 4.1 DIMENSIONS Standard Reducer 12345.75"/140 mm straight reducer Optional Reducers 9.0"/229 mm straight reducer 13.0"/330 mm straight reducer 2.62"/ 66.5 mm 4.83"/ 122.7 mm Short 90° elbow reducer Long 90° elbow reducer NOTE • The Short 90° elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. • FM/VdS Approved Only. Low Profile 2.84"/ 72 mm 1.4"/ 36 mm 1.4"/ 36 mm 4.59"/ 116 mm Short 90° elbow reducer Long 90° elbow reducer NOTE • Style AB11: When low profiles elbows are used with the Style AB11 bracket, the Low Profile Short Elbow is typically used with concealed sprinklers while the Low Profile Long Elbow is typically used in the installation of recessed pendent sprinklers. 6.57"/ 166.9 mm 2.62"/ 66.5 mm 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 6 victaulic.com 4.2 DIMENSIONS VicFlex Brackets Style AB1 • Suspended Ceilings • Hard-Lid Ceilings (FM Only) Item Description 1 24"/610 mm or 48"/1220 mm Square Bar 2 Patented Center Bracket 3 End Bracket NOTE • Both sizes FM/VdS/LPCB approved, cULus listed Style AB2 • Suspended Ceilings • Hard-Lid Ceilings Item Description 1 24"/610 mm or 48"/1220 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket NOTE • Both sizes FM/VdS/LPCB approved, cULus listed Style AB3 • Surface Mount Applications • FM/LPCB Approved 3 2 1 3 3 2 1 3 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 7 victaulic.com 4.3 DIMENSIONS VicFlex Brackets Style AB4 • Hard-Lid Ceilings with Hat furring channel grid system Item Description 1 24"/610 mm or 48"/1220 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket for Hat Furring Channel NOTE • Both sizes FM/VdS/LPCB approved, cULus listed Style AB5 • Hard-Lid Ceilings Item Description 1 24"/610 mm or 48"/1220 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket NOTE • Both sizes FM/VdS/LPCB approved, cULus listed Style AB7 • Suspended Ceilings • Hard-Lid Ceilings Item Description 1 24"/610 mm or 48"/1220 mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket NOTE • Both sizes FM/VdS/LPCB approved. Style AB7 Adjustable • Suspended Ceilings • Hard-Lid Ceilings Item Description 1 700 mm or 1400 mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket (adjustable) NOTE • Both sizes FM/VdS/LPCB approved. 3 2 1 3 3 2 1 3 3 2 1 3 3 2 1 3 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 8 victaulic.com 4.4 DIMENSIONS VicFlex Brackets Style AB8 • Hard-Lid Ceilings Item Description 1 700 mm or 1400 mm Square Bar* 2 Patented Vertically Adjustable Center Bracket 3 *Both sizes FM/VdS NOTE • Both sizes FM/VdS/LPCB approved. Style AB10 • Suspended ceilings • Armstrong® TechZone™ Item Description 1 6"/152 mm Square Bar* 2 Patented 1-Bee2® Center Bracket 3 End Bracket NOTE • FM/VdS/LPCB approved, cULus listed. Style AB11 • Suspended ceilings • Hard-Lid ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket NOTE • FM/VdS Approved, cULus listed. Style AB12 • Suspended ceilings • Hard-Lid ceilings Item Description 1 Style AB12 Bracket Body 2 #2 Square Drive Set Screw NOTE • FM/VdS Approved. 3 2 1 3 2 1 3 2 1 3 2 1 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 4.5 DIMENSIONS VicFlex Brackets Style ABBA • Floor-above mount • Cantilever mount • Temporary mount in exposed ceilings Item Description 1 Style ABBA Mounting Plate 2 Style ABBA Square Bar 3 Cap Screw, Serated Flange, M6 x 1 x 20, T25 Torx Drive Recessed 4 Style ABMM Bracket Body 5 Cap Screw, Serated Flange, M6 x 1 x 15.24, T25 Torx Drive Recessed Style ABMM • Surface mount • Stand-off mount Item Description 1 Style ABMM Bracket Body 2 Cap Screw, Serated Flange, M6 x 1 x 15.24, T25 Torx Drive Recessed 2 4 3 1 5 2 1 9 victaulic.com 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 10 victaulic.com 4.6 DIMENSIONS CLEARANCES ABOVE CEILING Series AH1 Braided Hose and Style AB1 Bracket Suspended Ceiling Grid with Recessed Sprinkler Suspended Ceiling Grid with Concealed Sprinkler V2707 MAX. EXTENSION R See chart A See Chart V2707 ¾"/19 mm MAX. RECESS 4.4"/ 113 mm 1.7"/43 mm Typical ceiling grid 24"/610 mm or 48"/1219 mm on Center /"/16 mm Typical ceiling tile See note Finished ceiling face Bracket assembly Style AB1 2/"/60 mm max. hole 2"/51 mm min. hole R See chart A See Chart V3802 ½"/12.7 MM MAX. RECESS V3802 MAX. EXTENSION 1.7"/43 mm Typical ceiling grid 24"/610 mm or 48"/1219 mm on Center /"/15.9 mm Typical ceiling tile See note Finished ceiling face 2/"/68.3 mm max. hole 2/"/60.3 mm min. hole Bracket Assembly Style AB1 4.4"/113 mm V2707 ¾"/19mm Max. Recess V3802 ½"/12.7mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min.8.6 218 9.6 244 10.6 269 11.6 295 12.6 320 13.6 345 A Min.10.1 269 11.1 281 12.1 307 13.1 333 14.1 358 15.1 383 Suspended Ceiling Grid with Recessed Sprinkler with 90° Elbow (Long) Suspended Ceiling Grid with Concealed Sprinkler with 90° Elbow (Short) A See Chart 4.4"/ 113 mm 1.7"/43 mm Typical ceiling grid 24"/610 mm or 48"/1219 mm on Center /"/16 mm Typical ceiling tile See note Finished ceiling face Bracket assembly Style AB1 V2707 MAX. EXTENSIONV2707 ¾" /19 mm MAX. RECESS 2/"/60 mm max. hole 2"/51 mm min. hole See note Finishedceiling face Bracket AssemblyStyle AB1 24"/610 mm or 48"/1219 mm on Center 2/"/68 mm max. hole 2/"/60 mm min. holeA See Chart /"/16 mm Typical ceiling tile V3802 MAX. EXTENSIONV3802 ½"/12.7 mm MAX. RECESS 4.4"/ 113 mm 1.7"/43 mm Typical ceiling grid V2707 ¾"/19mm Max. Recess V3802 ½"/12.7mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm A Min.8.0 200 A Min.5.8 147 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 11 victaulic.com 4.7 DIMENSIONS CLEARANCES ABOVE CEILING Series AH1 Braided Hose and Style AB2 Bracket Hard-lid Ceiling with Concealed Sprinkler Hard-lid Ceiling with Recessed Sprinkler A See chart Finished ceiling face 2⁄"/60 mm max. hole 2"/51 mmmin. hole3.5"/ 89 mm 16"/406 mm Stud C/C 1.8"/ 45 mm2" × 4" Stud Bracket assembly Style AB2 #10 Screw V2707 MAX. EXTENSION R See chart V2707 ¾"/19 mm MAX. RECESS V3802 ½"/12.7mm Max. Recess V2707 ¾"/19mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min.7.6 193 8.6 218 9.6 244 10.6 269 11.6 295 12.6 320 A Min.6.1 155 7.1 180 8.1 206 9.1 231 10.1 256 11.1 282 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. Hard-lid Ceiling Grid with Concealed Sprinkler with 90° Elbow (Short) Hard-lid Ceiling with Recessed Sprinkler with 90° Elbow (Long) A See chart Finished ceiling face 2¾"/68 mm max. hole 2 ⁄"/59 mm min. hole 3.5"/ 89 mm 16"/406 mm Stud C/C 1.8"/ 45 mm V3802 ½"/13 mm MAX. RECESS 2" × 4" Stud Bracket assembly Style AB2 #10 Screw V3802 MAX. EXTENSION A See chart Finished ceiling face 2⁄"/60 mm max. hole 2"/51 mm min. hole3.5"/89 mm 16"/406 mm Stud C/C 1.8"/ 45 mm2" × 4" Stud Bracket assembly Style AB2#10 Screw V2707 MAX. EXTENSIONV2707 ¾"/19 mm MAX. RECESS V3802 ½"/12.7mm Max. Recess V2707 ¾"/19mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm A Min.5.0 127 A Min.3.6 91 V3802 ½"/13 mm MAX. RECESS V3802 MAX. EXTENSION ASee chart Finished ceiling face 2¾"/68 mmmax. hole 2 ⁄"/59 mmmin. hole 3.5"/89 mm 16"/406 mm Stud C/C 1.8"/45 mm2" × 4" Stud Bracket assemblyStyle AB2#10 Screw RSee chart 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 12 victaulic.com 4.8 DIMENSIONS CLEARANCES WITHIN SIDEWALL Series AH1 Braided Hose and Style AB2 Bracket Horizontal Sidewall Sprinkler Horizontal Sidewall Sprinkler with 90° Elbow (Long) A See chart Finished ceiling face 2⁄"/60 mmmax. hole 2"/51 mmmin. hole3.5"/ 89 mm 16"/406 mm Stud C/C 1.8"/ 45 mm2" × 4" Stud Bracket assembly Style AB2 #10 Screw V2709 MAX. EXTENSION R See chart V2709 ¾"/19 mm MAX. RECESS ASee chart Finished ceiling face 2⁄"/60 mm max. hole 2"/51 mm min. hole3.5"/ 89 mm 16"/406 mm Stud C/C 1.8"/ 45 mm2" × 4" Stud Bracket assembly Style AB2 #10 Screw V2709 ¾"/19 mm MAX. RECESS V2709 MAX. EXTENSION V2707 ¾"/19mm Max. Recess V2707 ¾"/19mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min.3.6 91 A Min.6.1 155 7.1 180 8.1 206 9.1 231 10.1 256 11.1 282 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 13 victaulic.com 4.9 DIMENSIONS CLEARANCES ABOVE CEILING Series AH1 Braided Hose and Style AB4 Bracket Hat Furring Channel Grid with Recessed Sprinkler R See chart ASee Chart V2707 ¾"/19.1 MM MAX. RECESS V2707 MAX. EXTENSION /"/23 mm Typical ceiling grid Typical 16"/406 mm – 24"/610 mm on Center /"/15.9 mm Typical ceiling tileSee note Finished ceiling face 2/"/60 mm max. hole 2"/51 mm min. hole V2707 ¾"/19mm Max. Recess Hose Clearance Chart Dimension inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min.8.8 224 9.8 249 10.8 274 11.8 300 12.8 325 13.8 351 Hat Furring Channel Grid with Recessed Sprinkler with 90° Elbow (Long) Hat Furring Channel Grid with Concealed Sprinkler with 90° Elbow (Short) A See Chart /"/23 mm Typical ceiling gridTypical 16"/406 mm – 24"/610 mm on Center /"/16 mmTypical ceiling tile See note Finished ceiling face V2707 ¾"/19.1 MM MAX. RECESS V2707 MAX. EXTENSION 2/"/60 mm max. hole 2"/51 mmmin. hole See Note V3802 MAX. EXTENSIONV3802 ½"/12.7 mm MAX. RECESS Finishedceiling face 16"/406 mm – 24"/610 mm on Center A See Chart /"/23 mm Typical ceiling grid 2/"/60 mmmax. hole 2"/51 mm min. hole /"/16 mmTypical ceiling tile V2707 ¾"/19mm Max. Recess V2707 ¾"/19mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm A Min.8.0 200 A Min.5.9 149 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 14 victaulic.com 4.10 DIMENSIONS CLEARANCES ABOVE CEILING Series AH1 Braided Hose and Style AB5 Bracket Hard-lid Ceiling with Recessed Sprinkler Hard-lid Ceiling with Concealed Sprinkler V2707 ¾"/19mm Max. Recess V3802 ½"/13mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min.6.1 155 7.1 180 8.1 206 9.1 231 10.1 256 11.1 282 A Min.7.6 193 8.6 218 9.6 244 10.6 269 11.6 295 12.6 320 Hard-lid Ceiling with Concealed Pendent with 90° Elbow (Long) Hard-lid Ceiling with Recessed Pendent with 90° Elbow (Short) V3802 ½"/13mm Max. Recess V2707 ¾"/19mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm A Min.3.6 91 A Min.3.3 84 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. A See chart Finished ceiling face 2 ⁄"/60 mm max. hole /"/16 mm Typ. Drywall 2"/51 mm min. hole3.5"/ 89 mm 16"/406 mm Stud C/C 2.3"/ 57 mm V2707 ¾"/19 mm MAX. RECESS 2" × 4" Stud Bracket assembly Style AB5#10 Screw V2707 MAX. EXTENSION R See chart A See chart Finished ceiling face 2¾"/68 mm max. hole /"/16 mm Typ. Drywall 2 ⁄"/59 mm min. hole 3.5"/ 89 mm 16"/406 mm Stud C/C 2.3"/ 57 mm V3802 ½"/13 mm MAX. RECESS 2" × 4" Stud Bracket assembly Style AB5#10 Screw V3802 MAX. EXTENSION R See chart ASee chart 2⁄"/68 mmmax. hole /"/16 mmTyp. Drywall 2 ⁄"/59 mm min. hole 3.5"/ 89 mm 16"/406 mm Stud C/C 2.3"/ 57 mm V3802 ½"/13 mm MAX. RECESS 2" × 4" Stud Bracket assembly Style AB5 #10 Screw V3802 MAX. EXTENSION A See chart 2 ⁄"/60 mm max. hole /"/16 mm Typ. Drywall 2"/51 mm min. hole3.5"/ 89 mm 16"/406 mm Stud C/C 2.3"/57 mm V2707 ¾"/19 mm MAX. RECESS 2" × 4" Stud Bracket assembly Style AB5 #10 Screw V2707 MAX. EXTENSION Finished ceiling face 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 15 victaulic.com 4.11 DIMENSIONS CLEARANCES ABOVE CEILING Series AH1 Braided Hose and Style AB11 Bracket (LOW PROFILE SOLUTION) Suspended Ceiling Grid with Recessed Sprinkler with LP 90° Elbow (Long) A See chart 2 ⁄"/60 mm max. hole /"/16 mm Typical ceiling tile 2"/51 mm min. hole 3"/ 76 mm 24"/610 mm or 48"/1219 mm on Center 1.7"/43 mm Typical ceiling grid V2707 ¾"/19 mm MAX. RECESS See Note Bracket assembly Style AB11 V2707 MAX. EXTENSION Finished ceiling face Hose Clearance Chart Dimension inches mm A Min.4.0 100 Suspended Ceiling Grid with Concealed Pendent with LP 90° Elbow (Short) A See chart 2⁄"/68 mm max. hole /"/16 mm Typical ceiling tile 2 ⁄"/60 mm min. hole 3"/ 76 mm 24"/610 mm or 48"/1210 mm on Center 1.7"/43 mm Typical ceiling grid V3802 ½"/13 mm MAX. RECESS See Note Bracket assembly Style AB11 Finished Ceiling Face V3802 MAX. EXTENSION Hose Clearance Chart Dimension inches mm A Min.3.9 99 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 4.12 DIMENSIONS CLEARANCES ABOVE CEILING Series AH1 Braided Hose and Style AB12 and ABBA Bracket Suspended Ceiling Grid with Recessed Sprinkler with Low Profile Short Elbow Suspended Ceiling Grid with Recessed Sprinkler and Straight 5.75"/140mm Reducer "A" See Table 1⁄ inch/29 mm Finished Face of /-inch/16-mmTypical Ceiling Unnished Ceiling Face "B" See Table Square bar ⁄ inch/ 3 mm V2707 ½"/12.7 mm MAX. RECESS V2707 ¾"/19 mm MAX. RECESS Unnished Ceiling Face R "A" See Table 1⁄ inch/29 mm Finished Face of /-inch/16-mmTypical Ceiling "B" See Table Square bar Nominal length 14"/355.6 mm ⁄ inch/3 mm Dimension Low Profile Short Elbow Low Profile Long Elbow Standard Short Elbow Standard Long Elbow Standard Straight Reducer ¾"/19mm Recessed*Concealed ¾"/19mm Recessed Concealed ¾"/19mm Recessed Concealed ¾"/19mm Recessed Concealed ¾"/ 19mm Recessed Concealed inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm A Minimum Required Installation Space 4.0 101.6 5.5 139.7 5.6 142.2 7.2 182.9 5.9 149.9 7.5 190.5 7.7 195.6 9.3 236.2 15.0 381.0 16.6 421.6 B Distance from Top of Typical Ceiling Tile to Bottom of Gate 0.5 12.7 2.0 50.8 1.5 38.1 1.5 38.1 1.5 38.1 1.5 38.1 3.0 76.2 3.0 76.2 3.0 76.2 3.0 76.2 * Adjustability will be limited NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 4.13 DIMENSIONS Style ABMM Bracket Stand-off Dimensions 3.93"/ 100 mm 3.94"/ 100 mm 2.94"/ 75 mm 2.22"/ 56 mm 0.28"/ 7 mm 16 victaulic.com 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 4.13 DIMENSIONS BRANCHLINE CLEARANCES Series AH1 Braided Hose with female threaded outlet Series AH1-CC Braided Hose with grooved outlet Female Threaded Weld Outlet R See chart A See chart 2"/50 mm R See chart A See chart No. 142 Grooved Weld Outlet 2"/50 mm Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 3 80 4 100 5 125 6 150 7 175 R Minimum Bend Radius 3 80 4 100 5 125 6 150 7 175 A Min.9.4 239 10.4 264 11.4 290 12.4 315 13.41 341 A Min.8.1 205 9.1 231 10.1 256 11.1 281 12.1 307 17 victaulic.com 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 4.14 DIMENSIONS CLEARANCES ABOVE CEILING Series AH1 Braided Hose and Style AB3 and ABMM Bracket Surface Mount Application with Recessed Sprinkler R C B 3¾"/ 95.3 mm A 2⁄"/60 mm max. hole 2"/51 mm min. hole Hose Clearances Wall Thickness "A"2 50 4 100 6 150 8 200 10 250 2 50 4 100 6 150 8 200 10 250 Outlet Length "B" 5.75 146.1 9 228.6 13 330.2 5.75 146.1 9 228.6 13 330.2 9 228.6 13 330.2 13 330.2 13 330.2 5.75 146.1 9 228.6 13 330.2 5.75 146.1 9 228.6 13 330.2 9 228.6 13 330.2 13 330.2 13 330.2 Hose Clearance "C" 11.6 294 14.8 376 18.8 478 9.6 243 12.8 325 16.8 427 10.8 275 14.8 376 12.8 325 10.8 275 12.6 319 15.8 402 19.8 503 10.6 268 13.8 351 17.8 452 11.8 300 15.8 402 13.8 351 11.8 300 Bend Radius "R" 7 175 8 200 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. • See installation instructions for mounting screw type and size. 18 victaulic.com 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 4.15 DIMENSIONS BRANCHLINE CLEARANCES Series AH1 Braided Hose with Style 922 threaded outlet Series AH1-CC Braided Hose with Style 922 grooved outlet RSee chart A See chart Style 922 Threaded Mechanical Tee Outlet 2"/50 mm R See chart A See chart Style 922 Grooved Mechanical Tee Outlet 2"/50 mm Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 3 80 4 100 5 125 6 150 7 175 R Minimum Bend Radius 3 80 4 100 5 125 6 150 7 175 A Min.9.4 238 10.4 263 11.4 289 12.4 314 13.4 339 A Min.7.7 197 8.7 222 9.7 247 10.7 273 11.7 298 19 victaulic.com 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE – FRICTION LOSS DATA Series AH1 and AH1-CC Braided Hose with Straight 5.75" Reducers Style AB1, AB2, AB4, AB5 and AB10 Brackets Length of Stainless Steel Flexible Hose Outlet Size Equivalent Length of 1"/33.7 mm Sch. 40 Pipe (C=120) Maximum Number of 90° Bends at 3"/76.2 mm Bend Radius inches/mm inches/mm/type feet/meters 31/775 ½"/15/Straight 52/15.8 3 ¾"/20/Straight 55/16.8 3 36/900 ½"/15/Straight 63/19.2 4 ¾"/20/Straight 66/20.1 4 48/1200 ½"/15/Straight 78/23.8 4 ¾"/20/Straight 80/24.4 4 60/1500 ½"/15/Straight 88/26.8 4 ¾"/20/Straight 90/27.4 4 72/1800 ½"/15/Straight 112/34.1 5 ¾"/20/Straight 118/36.0 5 Series AH1 Braided Hose with 90° Low Profile Elbows Style AB11 VicFlex Bracket Equivalent Length of 1"/33.7 mm Sch. 40 Pipe Maximum Number of 90° Bends at 3"/76.2 mm Bend Radius inches/mm inches/mm/type feet/meters 31/775 ½"/15 63/19.2 3 ¾"/20 65/19.8 3 36/900 ½"/15 76/23.2 4 ¾"/20 76/23.2 4 48/1200 ½"/15 99/30.2 4 ¾"/20 98/29.9 4 60/1500 ½"/15 108/32.9 4 ¾"/20 102/31.1 4 72/1800 ½"/15 124/37.8 5 ¾"/20 132/40.2 5 20 victaulic.com 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE – FRICTION LOSS DATA Series AH1 Braided Hose Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 3"/76.2 mm center line bend radius Length of Stainless Steel Flexible Hose Outlet Size 1 Bend 2 Bends 3 Bends 4 Bends 5 Bends inches/mm inches/mm feet/meters feet/meters feet/meters feet/meters feet/meters 31/775 ½"/15 32/9.8 42/12.8 52/15.9 N.A N.A ¾"/20 33/10.1 44/13.4 55/16.8 N.A N.A 36/900 ½"/15 33/10.1 43/13.1 53/16.2 63/19.2 N.A ¾"/20 36/11.0 46/14.0 56/17.1 66/20.1 N.A 48/1200 ½"/15 46/14.0 57/17.4 68/20.7 78/23.8 N.A ¾"/20 51/15.5 60/18.3 71/21.6 88/26.8 N.A 60/1500 ½"/15 56/17.1 67/20.4 77/23.5 88/26.8 N.A ¾"/20 58/17.7 69/21.0 80/24.4 90/27.4 N.A 72/1800 ½"/15 69/21.0 79/24.1 91/27.7 102/31.1 112/34.1 ¾"/20 73/22.6 84/25.6 95/29.0 106/32.3 118/36.0 NOTES: • Values for use with 5.75" straight reducers. How to use this Design Guide: • For some systems, it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends. In this case, the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. • It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected. When this happens, the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations. The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. 21 victaulic.com 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE – FRICTION LOSS DATA Series AH1 and AH1-CC Braided Hose Style AB1, AB2, AB3, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB12, ABBA and ABMM VicFlex Brackets Equivalent Length of 1"/33.7mm Sch. 40 Pipe Maximum Number of 90° Bends at 7"/178mm Bend Radius inches/mm Imperial/S.I.inches/mm/type feet/meters 31/775 5.6/8.1 ½"/15/Straight 53.8/16.4 2½"/15/90˚ Elbow 53.8/16.4 36/900 5.6/8.1 ½"/15/Straight 63.7/19.4 2½"/15/90˚ Elbow 63.1/19.2 48/1200 5.6/8.1 ½"/15/Straight 87.9/26.8 3½"/15/90˚ Elbow 85.8/26.1 60/1500 5.6/8.1 ½"/15/Straight 112.2/34.1 4½"/15/90˚ Elbow 108.4/33.0 72/1800 5.6/8.1 ½"/15/Straight 136.5/41.6 4½"/15/90˚ Elbow 131.1/39.9 31/775 8.0/11.5 ¾"/20/Straight 44.4/13.5 2¾"/20/90˚ Elbow 47.6/14.5 36/900 8.0/11.5 ¾"/20/Straight 55.6/16.9 2¾"/20/90˚ Elbow 57.5/17.5 48/1200 8.0/11.5 ¾"/20/Straight 82.8/25.2 3¾"/20/90˚ Elbow 81.7/24.9 60/1500 8.0/11.5 ¾"/20/Straight 110.1/24.9 4¾"/20/90˚ Elbow 105.9/32.2 72/1800 8.0/11.5 ¾"/20/Straight 137.3/41.8 4¾"/20/90˚ Elbow 130.2/39.7 31/775 11.2/16.1 ¾"/20/Straight 45.5/13.8 2¾"/20/90˚ Elbow 47.1/14.3 36/900 11.2/16.1 ¾"/20/Straight 66.3/20.2 2¾"/20/90˚ Elbow 57.5/17.5 48/1200 11.2/16.1 ¾"/20/Straight 82.7/25.2 3¾"/20/90˚ Elbow 82.8/25.2 60/1500 11.2/16.1 ¾"/20/Straight 109.1/33.2 4¾"/20/90˚ Elbow 108.1/32.9 72/1800 11.2/16.1 ¾"/20/Straight 135.5/41.3 4¾"/20/90˚ Elbow 133.4/40.6 31/775 14.0/20.2 ¾"/20/Straight 44.3/13.5 2¾"/20/90˚ Elbow 46.4/14.1 36/900 14.0/20.2 ¾"/20/Straight 55.5/16.9 2¾"/20/90˚ Elbow 56.7/17.3 48/1200 14.0/20.2 ¾"/20/Straight 83.0/25.3 3¾"/20/90˚ Elbow 82.1/25.0 60/1500 14.0/20.2 ¾"/20/Straight 110.4/33.6 4¾"/20/90˚ Elbow 107.5/32.7 72/1800 14.0/20.2 ¾"/20/Straight 137.9/42.0 4¾"/20/90˚ Elbow 132.8/40.4 FM NOTES: • Series AH1 has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 and Vds standards for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. • EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 22 victaulic.com 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE – FRICTION LOSS DATA Series AH1 Braided Hose with 90° Low Profile Elbows Style AB5, AB11, AB12, ABBA and ABMM VicFlex Bracket Length of Stainless Steel Flexible Hose K-Factor Outlet Size Equivalent Length of 1"/33.7mm Sch. 40 Pipe Maximum Number of 90° Bends at 7"/178mm Bend Radius inches/mm Imperial/S.I.inches/mm feet/meters 31/775 5.6/8.1 ½"/15 49.0/14.9 2 36/900 5.6/8.1 ½"/15 58.5/17.8 2 48/1200 5.6/8.1 ½"/15 81.5/24.8 3 60/1500 5.6/8.1 ½"/15 104.4/31.8 4 72/1800 5.6/8.1 ½"/15 127.4/38.8 4 31/775 8.0/11.5 ¾"/20 47.6/14.5 2 36/900 8.0/11.5 ¾"/20 57.7/17.6 2 48/1200 8.0/11.5 ¾"/20 81.9/25.0 3 60/1500 8.0/11.5 ¾"/20 106.1/32.3 4 72/1800 8.0/11.5 ¾"/20 130.5/39.8 4 31/775 11.2/16.1 ¾"/20 48.6/14.8 2 36/900 11.2/16.1 ¾"/20 58.2/17.7 2 48/1200 11.2/16.1 ¾"/20 82.2/25.1 3 60/1500 11.2/16.1 ¾"/20 104.2/31.8 4 72/1800 11.2/16.1 ¾"/20 127.5/38.8 4 31/775 14.0/20.2 ¾"/20 47.9/14.6 2 36/900 14.0/20.2 ¾"/20 58.0/17.7 2 48/1200 14.0/20.2 ¾"/20 82.2/25.1 3 60/1500 14.0/20.2 ¾"/20 106.4/32.4 4 72/1800 14.0/20.2 ¾"/20 130.8/39.9 4 FM NOTES: • Series AH1 has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 and Vds standards for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. • Differences in equivalent lengths are due to varying test methods, per FM 1637 and VdS standards. Refer to these standards for additional information regarding friction loss test methods. • EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends at a 7-inch bend radius is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 23 victaulic.com 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE – FRICTION LOSS DATA Series AH1 and AH1-CC Braided Hose Style AB1, AB2, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB11 and AB12 Brackets Length of Stainless Steel Flexible Hose Outlet Size Equivalent Length of steel pipe according to EN 10255 DN 20 (26,9 x 2,65) Maximum Number of 90º Bends at 3"/76.2mm Bend Radius mm/inches mm/inches/type meters/feet meters/feet 790/31 15mm/½"/Straight 4.0/12.9 320 mm/¾"/Straight 915/36 15mm/½"/Straight 4.6/15.0 320 mm/¾"/Straight 1220/48 15mm/½"/Straight 6.1/20.0 320 mm/¾"/Straight 1525/60 15mm/½"/Straight 7.6/25.0 420 mm/¾"/Straight 1830/72 15mm/½"/Straight 9.2/30.0 420 mm/¾"/Straight VDS CEILING MANUFACTURERS LIST AB1, AB2, AB7, AB10, AB11, AB12 AB4 AB8 1. AMF 2. Armstrong 3. Chicago Metallic 4. Dipling 5. Durlum 6. Geipel 7. Gema-Armstrong 8. Hilti 9. Knauf 10. Lafarge 11. Linder 12. Odenwald 13. Richter 14. Rigips 15. Rockfon Pagos 16. Suckow & Fischer 17. USG Donn No specific approval 1. Hilti 2. Knauf 3. Lafarge 4. Lindner 5. Rigips 24 victaulic.com 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE – FRICTION LOSS DATA (continued) Series AH1 and AH1-CC Braided Hose Style AB1, AB2, AB3, AB4, AB5, AB7, AB8 and AB10 Brackets Length of Stainless Steel Flexible Hose Outlet Size Equivalent Length of steel pipe according to EN 10255 DN 25 (33,7 x 3,25) Maximum Number of 90º Bends at 3"/76.2mm Bend Radius mm/inches mm/inches/type meters/feet 790/31 15mm/½"/Straight 12.7/41.8 220 mm/¾"/Straight 15mm/½"/90º Elbow 13.6/44.6 220 mm/¾"/90º Elbow 915/36 15mm/½"/Straight 16.4/53.8 320 mm/¾"/Straight 15mm/½"/90º Elbow 16.9/55.4 320 mm/¾"/90º Elbow 1220/48 15mm/½"/Straight 19.6/64.3 320 mm/¾"/Straight 15mm/½"/90º Elbow 19.9/65.1 320 mm/¾"/90º Elbow 1525/60 15mm/½"/Straight 24.0/78.8 320 mm/¾"/Straight 15mm/½"/90º Elbow 24.5/80.2 320 mm/¾"/90º Elbow 1830/72 15mm/½"/Straight 27.8/91.1 320 mm/¾"/Straight 15mm/½"/90º Elbow 28.5/93.4 320 mm/¾"/90º Elbow Series AH1 Flexible Hose Friction Loss Data Model Length of Flexible Hose Equivalent Length Straight Configuration Bend Configuration mm inches meters feet meters feet AH1-31 790 4.78 5.80 31 15.7 19.0 AH1-36 915 5.59 10.15 36 18.3 33.3 AH1-48 1120 9.75 16.25 48 32.0 53.3 AH1-60 1525 12.15 22.94 60 39.9 75.3 AH1-72 1830 14.26 25.98 72 46.8 85.2 NOTE • Friction loss data is in accordance with GB5135.16 tested at a flow rate of 114 liters per minute (30 gallons per minute). 25 victaulic.com 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 6.0 NOTIFICATIONS WARNING • Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Always verify that the piping system has been completely depressurized and drained immediately prior to installa- tion, removal, adjustment, or maintenance of any Victaulic products. • Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. WARNING • It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. • The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. 26 victaulic.com 10.95 8507 Rev J Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms “Patented” or “Patent Pending” refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to I-VICFLEX-AB1-AB2-AB10, I-VICFLEX-AB4-AB9, I-VICFLEX-AB7, or I-VICFLEX-AB8 for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 7.0 REFERENCE MATERIALS – CHARACTERISTICS Flexible Hose In-Plane Bend Characteristics One Bend Two Bends Three Bends 90° Minimum bend radius Minimum bend radius Minimum bend radius 2X Minimum bend radius OR Minimum bend radius Minimum bend radius Minimum bend radius 2X Minimum bend radius Minimum bend radius OR NOTE • For out-of-plane (three-dimensional) bends, care must be taken to avoid imparting torque on the hose. I-VicFlex-AB1-AB2-AB10 I-VicFlex-AB3 I-VicFlex-AB4 I-VicFlex-AB7 I-VicFlex-AB8 I-VicFlex-AB12 I-VicFlex-ABBA I-VicFlex-ABMM 27 victaulic.com victaulic.com 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. Series AH2 Series AH2-CC 1.0 PRODUCT DESCRIPTION Available Sizes by Component • Series AH2 1"/DN25 Nominal ID Braided Hose: 31, 36, 48, 60, 72"/790, 915, 1220, 1525, 1830 mm. Note: length includes adapter nipple and 5.75"/140 mm straight reducer. • Series AH2-CC 1"/DN25 Nominal ID Braided Hose: 31, 36, 48, 60, 72"/790, 915, 1220, 1525, 1830 m Note: length includes captured coupling and 5.75"/140 mm straight reducer. • Sprinkler Reducers: • Sprinkler Connections: ½ and ¾"/15 and 20 mm • Straight Lengths: 5.75, 9, 13"/140, 230, 330 mm • 90º Elbows: • Short (typically used with concealed sprinklers) • Long (typically used with recessed pendent sprinklers) • Low Profile Short (for use with Style AB5, AB11, AB12, ABBA and ABMM Bracket) • Low Profile Long (for use with Style AB5, AB11, AB12, ABBA and ABMM Bracket) m. • Inlet Connections: • 1"/25 mm Grooved IGS • 1"/25 mm NPT or BSPT adapter nipples for attaching to pipe and fittings outlined in NFPA standards. • ¾"/20 mm NPT or BSPT adapter nipples available for VdS. • 1 ¼"/ 32 mm BSPT adapter nipples available for LPCB. Victaulic® VicFlex™ Sprinkler Fittings Series AH2 and AH2-CC Braided Flexible Hoses 10.85 1 System No.Location Submitted By Date Spec Section Paragraph Approved Date 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 2 victaulic.com 1.0 PRODUCT DESCRIPTION (Continued) • Brackets: • Style AB1 for suspended and hard-lid ceilings and sidewalls, allows installation before most ceiling tiles in place • Style AB2 for suspended and hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place • Style AB3 for surface mount applications, wood, metal and block walls, or ceilings • Style AB4 for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment • Style AB5 for hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment • Style AB7 for suspended and hard-lid ceilings • Style AB7 Adjustable for suspended and hard-lid ceilings • Style AB8 for hard-lid ceilings with CD 60/27 profile metal studs (regionally available) • Style AB9 for hard-lid ceilings with hat furring channel grid systems • Style AB10 for Armstrong® TechZone™ ceilings • Style AB11 for lay-in panel suspended t-grid ceilings or drywall suspended t-grid ceilings, allows for low profile installations (use only with 90° low profile elbows) • Style AB12 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and allows for low profile installation down to 4"/100mm. • Style ABBA bracket for suspended, exposed, and hard-lid ceilings • Style ABMM bracket for surface mount and stand off-mount applications, wood, metal and block walls, or ceilings and hard-lid ceilings Maximum Working Temperature • 225°F/107°C Maximum Working Pressure • 200 psi/1375 kPa (FM Approval) • 175 psi/1206 kPa (cULus Listed) • 1600 kPa/232 psi (VdS/LPCB Approved) • 1.4 MPa (CCCf Approved) Connections • To adapter nipple (inlet) via • 1"/25.4 mm Grooved IGS • 1"/25.4 mm NPT or BSPT male thread • ¾"/20 mm BSPT male thread (VdS only) • 1 ¼"/32 mm BSPT male thread (LPCB only) • To sprinkler head (outlet) via ½" or ¾"/15 mm or 20 mm Minimum Bend Radius • 7"/178 mm (FM/CCCf Approval) • 2"/51 mm (cULus Listed) • 3"/76.2 mm (VdS/LPCB Approved) Maximum Allowable Sprinkler K-Factors • FM (½"/15 mm reducer) K5.6/8,1 (S.I.), (¾"/20 mm reducer) K14.0/20,2 (S.I.) • cULus (½"/15 mm reducer) K8.0/11,5 (S.I.), (¾"/20 mm reducer) K14.0/20,2 (S.I.) • VdS/LPCB (½"/15 mm reducer) K5.6/8,1 (S.I.), (¾"/20 mm reducer) K8.0/11,5 (S.I.) 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 3 victaulic.com 2.0 CERTIFICATION/LISTINGS NOTE • The VicFlex Series AH2 Hose has been tested and evaluated by Spears® for acceptable use with Spears® CPVC Products and is therefore covered under the Spears® FlameGaurd® Installer Protection Plan. 3.0 SPECIFICATIONS – MATERIAL Series AH2 • Flexible Hose: 300-series Stainless Steel • Collar/Weld Fitting: 300-series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (½"/15 mm or ¾"/20 mm): Carbon Steel, Zinc-Plated • Low Profile Elbows: Ductile Iron, Zinc-Plated Brackets: Carbon Steel, Zinc-Plated Series AH2-CC • Flexible Hose: 300-series Stainless Steel • Collar/Weld Fitting: 300-series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Coupling Retainer Ring: Polyethelene • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (½"/15 mm or ¾"/20 mm): Carbon Steel, Zinc-Plated • Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Coupling Housing Coating: • Orange enamel (North America, Asia Pacific). • Red enamel (Europe). • Hot dipped galvanized. Gasket:1 • Grade “E” EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. • Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. • Linkage: CrMo Alloy Steel zinc electroplated per ASTM B633 Zn/Fe 5, Type III Finish 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 4 victaulic.com 4.0 DIMENSIONS Product Details - Series AH2 Braided Hose B 371 2 4685 A Item Description 1 Flexible Hose 2 Isolation Ring 3 Gasket 4 Nut 5 Adapter Nipple 6 Braid 7 Collar/Weld Fitting 8 Sleeve Hose Length Dimensions Hose Length A B inches mm inches mm inches mm 31/790 25.3/641 31/790 36/915 31.3/794 36/915 48/1219 42.3/1073 48/1220 60/1525 54.3/1378 60/1525 72/1830 66.3/1683 72/1830 Series AH2-CC Braided Hose Hose Length A B inches mm inches mm inches mm 31/790 24.5/622 29.8/757 36/915 29.5/749 34.8/884 48/1219 41.5/1054 46.8/1189 60/1525 53.5/1359 58.8/1494 72/1830 65.5/1664 70.8/1798 BA 3712 468 5 Item Description 1 Flexible Hose 2 Isolation Ring 3 Gasket 4 Nut 5 Captured Coupling 6 Braid 7 Collar/Weld Fitting 8 Sleeve 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5 victaulic.com 4.0 DIMENSIONS (C ontinued) Standard Reducer 12345.75"/140 mm straight reducer Optional Reducers 9.0"/229 mm straight reducer 13.0"/330 mm straight reducer 2.62"/ 66.5 mm 4.83"/ 122.7 mm 6.57"/ 166.9 mm 2.62"/ 66.5 mm Short 90° elbow reducer Long 90° elbow reducer NOTE • The Short 90° elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. • FM/VdS Approved only. Low Profile 2.84"/ 72 mm 1.4"/ 36 mm 1.4"/ 36 mm 4.59"/ 116 mm Short 90° elbow reducer Long 90° elbow reducer NOTE • Style AB11: When low profiles elbows are used with the Style AB11 bracket, the Low Profile Short Elbow is typically used with concealed sprinklers while the Low Profile Long Elbow is typically used in the installation of recessed pendent sprinklers. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 6 victaulic.com 4.1 DIMENSIONS VicFlex Brackets Style AB1 • Suspended Ceilings • Hard-Lid Ceilings (FM Only) Item Description 1 24"/610 mm or 48"/1219 mm Square Bar 2 Patented Center Bracket 3 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved, cULus listed Style AB2 • Suspended Ceilings • Hard-Lid Ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved, cULus listed Style AB3 • Surface Mount Applications • FM/LPCB Approved 3 2 1 3 3 2 1 3 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 7 victaulic.com 4.2 DIMENSIONS VicFlex Brackets Style AB4 • Hard-Lid Ceilings with Hat furring channel grid system Item Description 1 24"/610 mm or 48"/1219 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket for Hat Furring Channel NOTE • Both sizes FM/VdS/LPCB Approved, cULus listed. Style AB5 • Hard-Lid Ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved, cULus listed. Style AB7 • Suspended Ceilings • Hard-Lid Ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved. Style AB7 Adjustable • Suspended Ceilings • Hard-Lid Ceilings Item Description 1 700 mm or 1400 mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket (adjustable) NOTE • Both sizes FM/VdS/LPCB Approved. 3 2 1 3 3 2 1 3 3 2 1 3 3 2 1 3 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 8 victaulic.com 4.3 DIMENSIONS VicFlex Brackets Style AB8 • Hard-Lid Ceilings Item Description 1 700 mm or 1400 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved. Style AB10 • Suspended ceilings • Armstrong® TechZone™ Item Description 1 6"/152 mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket NOTE • FM/VdS/LPCB Approved, cULus listed. Style AB11 • Suspended ceilings • Hard-Lid ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket NOTE • FM/VdS Approved, cULus listed. Style AB12 • Suspended ceilings • Hard-Lid ceilings Item Description 1 Style AB12 Bracket Body 2 #2 Square Drive Set Screw NOTE • FM/VdS Approved. 2 1 3 2 1 3 3 2 1 3 2 1 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 9 victaulic.com 4.3 DIMENSIONS (CONTINUED) VicFlex Brackets Style ABBA • Floor-above mount • Cantilever mount • Temporary mount in exposed ceilings Item Description 1 Style ABBA Mounting Plate 2 Style ABBA Square Bar 3 Cap Screw, Serated Flange, M6 x 1 x 20, T25 Torx Drive Recessed 4 Style ABMM Bracket Body 5 Cap Screw, Serated Flange, M6 x 1 x 15.24, T25 Torx Drive Recessed Style ABMM • Surface mount • Stand-off mount Item Description 1 Style ABMM Bracket Body 2 Cap Screw, Serated Flange, M6 x 1 x 15.24, T25 Torx Drive Recessed 2 4 3 1 5 2 1 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 10 victaulic.com 4.4 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB1 Bracket A See Chart 1.7"/43 mm Typical ceiling grid 24"/610 mm or 48"/1219 mm on Center /"/ 15.9 mm Typical ceiling tile See note Finished ceiling face Bracket AssemblyStyle AB1 2⁄"/60 mm max. hole 2"/51 mm min. hole 2⁄"/68 mm max. hole 2⁄"/60 mm min. hole4.4"/ 113 mm R V38V27Pendent Hose Clearance Chart Straight Reducer Long Elbow Short Elbow V2707 V3802 V2707 V3802 ¾" ½" ¾" ½" V2707 V3802 V2707 V3802 Max Recess Max Recess Max Recess Max Recess ¾" Max Recess ½" Max Recess ¾" Max Recess ½" Max Recess inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm "R" Minimum 2.0 3.0 7.0 –Bend Radius 50 80 175 "A" Minimum Required 8.6 10.1 9.6 11.1 13.6 15.1 5.8 5.8 Installation 218 269 244 281 345 383 147 147 Space NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 11 victaulic.com 4.5 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket A See Chart 3.5"/ 89 mm 16"/406 mm Stud C/C #10 Screw2 x 4" Stud Finished ceiling Bracket Assembly Style AB2 2⁄"/60 mm max. hole 2"/51 mm min. hole 2⁄"/60 mm max. hole 2"/51 mm min. hole 2⁄"/68 mm max. hole 2⁄"/60 mm min. hole 1.8"/45 mm R V27Sidewall V27PendentV38 Hose Clearance Chart Straight Reducer V2707 V3802 V2709 V2707 V3802 V2709 V2707 V3802 V2709 ¾" | 20 mm ½" | 13 mm ¾" | 20 mm ¾" | 20 mm ½" | 13 mm ¾" | 20 mm ¾" | 20 mm ½" | 13 mm ¾" | 20 mm Max Recess"Max Recess Sidewall Max Recess Max Recess Sidewall Max Recess Max Recess Sidewall inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm "R" Minimum 2.0 3.0 7.0 Bend Radius 50 80 175 "A" Minimum Required 6.2 7.6 6.1 7.2 8.6 7.1 11.2 12.6 11.1 Installation 158 193 155 183 218 180 285 320 282 Space Hose Clearance Chart Long Elbow Short Elbow V2707 ¾" | 20 mm Max Recess V2709 ¾" | 20 mm Sidewall V3802 ½" | 13 mm Max Recess inches mm inches mm inches mm "R" Minimum Bend Radius – "A" Minimum Required Installation Space 3.3 84 3.6 91 3.3 84 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 12 victaulic.com 4.6 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB4 Bracket ASee Chart Typical 16"/406 mm – 24"/610 mm on Center /"/15.9 mm Typical ceiling tile /"/23 mm Typical ceiling grid See note Typical nished ceiling face 2⁄"/60 mm max. hole 2"/51 mm min. hole 2⁄"/68 mm max. hole 2⁄"/60 mm min. hole R V38V27Pendent Hose Clearance Chart Straight Reducer Long Elbow Short Elbow V2707 V3802 V2707 V3802 ¾" ½" ¾" ½" V2707 V3802 V2707 V3802 Max Recess Max Recess Max Recess Max Recess ¾" Max Recess ½" Max Recess ¾" Max Recess ½" Max Recess inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm "R" Minimum 2.0 2.0 3.0 3.0 7.0 7.0 –Bend Radius 50 50 80 80 175 175 "A" Minimum Required 8.8 10.2 9.8 11.2 13.8 15.2 8.0 5.9 Installation 224 259 249 285 351 386 203 150 Space NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 13 victaulic.com 4.7 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB5 Bracket ASee Chart 2.3"/57 mm 16"/406 mm Stud C/C 2 x 4" MetalStud Finished ceiling face Bracket AssemblyStyle AB5 2⁄"/60 mm max. hole 2"/51 mm min. hole 2⁄"/60 mm max. hole 2"/51 mm min. hole 2⁄"/68 mm max. hole 2⁄"/60 mm min. hole 3.6"/ 92 mm R /"/15.9 mmDrywall V27SidewallV38V27Pendent Hose Clearance Chart Straight Reducer "V2707 V3802 V2709 V2707 V3802 V2709 V2707 V3802 V2709 ¾" | 20 mm ½" | 13 mm ¾" | 20 mm ¾" | 20 mm ½" | 13 mm ¾" | 20 mm ¾" | 20 mm ½" | 13 mm ¾" | 20 mm Max Recess"Max Recess Sidewall Max Recess Max Recess Sidewall Max Recess Max Recess Sidewall inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm "R" Minimum 2.0 3.0 7.0 Bend Radius 50 80 175 "A" Minimum Required 6.0 7.7 6.1 7.0 8.7 7.1 11.0 12.7 11.1 Installation 158 196 155 178 221 180 279 323 282 Space Hose Clearance Chart Long Elbow Low-Profile Long Elbow Short Elbow V2707 ¾" | 20 mm Max Recess V3802 ½" | 13 mm Max Recess V2709 ¾" | 20 mm Sidewall V3802 ½" | 13 mm Max Recess V3802 ½" | 13 mm Max Recess inches mm inches mm inches mm inches mm inches mm "R" Minimum Bend Radius – "A" Minimum Required Installation Space 3.5 89 4.9 124 3.6 91 2.9 74 3.3 84 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 14 victaulic.com 4.8 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB11 Bracket (LOW PROFILE SOLUTION) A See Chart See Note 1.7"/43 mm Typical ceiling grid 24"/610 mm or 48"/1219 mm on center Finished ceiling face Bracket Assembly Style AB11 2⁄"/60 mm max. hole 2"/51 mm min. hole 2⁄"/68 mm max. hole 2⁄"/60 mm min. hole 3.0"/ 76 mm /"/15.9 mm Typical ceiling tile V38V27Pendent Hose Clearance Chart Low-Profile Low-Profile Long Elbow Short Elbow V2707 V3802 ¾" | 20 mm ½" | 13 mm Max Recess"Max Recess inches inches mm mm "A" Minimum Required 4.0 3.9 Installation 102 99 Space NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 15 victaulic.com 4.9 DIMENSIONS Clearances Style AB12 and ABBA Bracket Suspended Ceiling Grid with Recessed Sprinkler with Low Profile Short Elbow Suspended Ceiling Grid with Recessed Sprinkler and Straight 5.75"/140 mm Reducer "A"See Table 1⁄ inch/ 29 mm Finished Face of /-inch/16-mm Typical Ceiling Unnished Ceiling Face "B" See Table Square bar ⁄ inch/3 mm V2707 ½"/12.7 mm MAX. RECESS V2707 ¾"/19 mm MAX. RECESS Unnished Ceiling Face R "A"See Table 1⁄ inch/ 29 mm Finished Face of /-inch/16-mm Typical Ceiling "B" See Table Square bar Nominal length 14"/355.6 mm ⁄ inch/3 mm Dimension Low Profile Short Elbow Low Profile Long Elbow Standard Short Elbow Standard Long Elbow Standard Straight Reducer ¾"/19 mm Recessed* inches mm Concealed inches mm ¾"/19 mm Recessed inches mm Concealed inches mm ¾"/19 mm Recessed inches mm Concealed inches mm ¾"/19 mm Recessed inches mm Concealed inches mm ¾"/19 mm Recessed inches mm Concealed inches mm A Minimum Required Installation Space 4.0 101.6 5.5 139.7 5.6 142.2 7.2 182.9 5.9 149.9 7.5 190.5 7.7 195.6 9.3 236.2 15.0 381.0 16.6 421.6 B Distance from Top of Typical Ceiling Tile to Bottom of Gate 0.5 12.7 2.0 50.8 1.5 38.1 1.5 38.1 1.5 38.1 1.5 38.1 3.0 76.2 3.0 76.2 3.0 76.2 3.0 76.2 * Adjustability will be limited Style ABMM Bracket Stand-off Dimensions 3.93"/ 100 mm 3.94"/ 100 mm 2.94"/ 75 mm 2.22"/ 56 mm 0.28"/ 7 mm 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 16 victaulic.com 4.10 DIMENSIONS Clearances Style AB3 and ABMM Bracket Surface Mount Application with Recessed Sprinkler R C B 3¾"/ 95.3 mm A 2⁄"/60 mm max. hole 2"/51 mm min. hole Hose Clearances inches inches inches inches inches inches inches inches inches inches Dimension mm mm mm mm mm mm mm mm mm mm Wall Thickness 2 4 6 8 10 2 4 6 8 10 "A"50 100 150 200 250 50 100 150 200 250 Outlet Length 5.75 9 13 5.75 9 13 9 13 13 13 5.75 9 13 5.75 9 13 9 13 13 13 "B"146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 Hose Clearance 11.6 14.8 18.8 9.6 12.8 16.8 10.8 14.8 12.8 10.8 12.6 15.8 19.8 10.6 13.8 17.8 11.8 15.8 13.8 11.8 "C"294 376 478 243 325 427 275 376 325 275 319 402 503 268 351 452 300 402 351 300 Bend Radius 7 8 "R"175 200 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE – FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hoses with Straight 5.75"/140 mm Reducers Style AB1, AB2, AB4, AB5 and AB10 Brackets Maximum Equivalent Length Number of of 1"/33.7 mm 90° Bends at 2"/51 mm Sch. 40 Pipe (C=120)Bend Radius inches/mm inches/mm/type feet/meters 31/790 ½"/15/Straight 16/4.9 4 ¾"/20/Straight 17/5.2 4 36/915 ½"/15/Straight 21/6.4 5 ¾"/20/Straight 23/7.0 5 48/1220 ½"/15/Straight 32/9.8 8 ¾"/20/Straight 37/11.3 8 60/1525 ½"/15/Straight 46/14.0 10 ¾"/20/Straight 46/14.0 10 72/1830 ½"/15/Straight 55/16.8 12 ¾"/20/Straight 53/16.2 12 Series AH2 and AH2-CC Braided Hose with 90° Low Profile Elbows Style AB11 VicFlex Bracket Equivalent Length of 1"/33.7 mm Sch. 40 Pipe Maximum Number of 90° Bends at 2"/51 mm Bend Radius inches/mm inches/mm feet/meters 31/790 ½"/15 24/7.3 4 ¾"/20 24/7.3 4 36/915 ½"/15 26/7.9 5 ¾"/20 28/8.5 5 48/1220 ½"/15 43/13.1 8 ¾"/20 42/12.8 8 60/1525 ½"/15 49/14.9 10 ¾"/20 50/15.2 10 72/1830 ½"/15 65/19.8 12 ¾"/20 63/19.2 12 17 victaulic.com 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE – FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hoses Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 2"/51 mm center line bend radius Length of Stainless Steel Flexible Hose inches/ mm Outlet Size inches/ mm 1 Bend feet/ meters 2 Bends feet/ meters 3 Bends feet/ meters 4 Bends feet/ meters 5 Bends feet/ meters 6 Bends feet/ meters 7 Bends feet/ meters 8 Bends feet/ meters 9 Bends feet/ meters 10 Bends feet/ meters 11 Bends feet/ meters 12 Bends feet/ meters 31/790 ½"/15 8.5/2.6 11.0/3.4 13.0/4.0 16.0/4.9 N.A N.A N.A N.A N.A N.A N.A N.A ¾"/20 10.0/3.0 12.5/3.8 14.0/4.3 17.0/5.2 N.A N.A N.A N.A N.A N.A N.A N.A 36/915 ½"/15 13.5/4.1 16.0/4.9 18.0/5.5 19.0/5.8 21.0/6.4 N.A N.A N.A N.A N.A N.A N.A ¾"/20 14.0/4.3 17.0/5.2 19.5/5.9 20.0/6.1 23.0/7.0 N.A N.A N.A N.A N.A N.A N.A 48/1220 ½"/15 15.5/4.7 17.0/5.2 19.5/5.9 20.0/6.1 21.0/6.4 22.0/6.7 28.0/8.5 32.0/9.8 N.A N.A N.A N.A ¾"/20 17.0/5.2 19.0/5.8 21.5/6.6 24.5/7.5 26.0/7.9 27.0/8.2 30.0/9.1 37.0/11.3 N.A N.A N.A N.A 60/1525 ½"/15 21.5/6.6 24.0/7.3 27.0/8.2 28.5/8.7 30.0/9.1 31.0/9.4 37.0/11.3 42.0/12.8 44.0/13.4 46.0/14.0 N.A N.A ¾"/20 23.0/7.0 24.0/7.3 28.0/8.5 29.5/9.0 30.5/9.3 31.0/9.4 38.0/11.6 42.0/12.8 44.0/13.4 46.0/14.0 N.A N.A 72/1830 ½"/15 30.0/9.1 32.0/9.8 36.5/11.1 37.5/11.4 40.5/12.5 41.0/12.8 42.0/12.8 46.0/14.0 49.0/14.9 52.0/15.8 54.0/16.5 55.0/16.8 ¾"/20 32.0/9.8 32.5/9.9 35.0/10.7 35.5/10.8 40.0/12.3 40.5/12.3 41.0/12.5 46.0/14.0 50.0/15.2 51.0/15.5 52.0/15.8 53.0/16.2 NOTES: • Values for use with 5.75"/140 mm straight reducers. How to use this Design Guide: • For some systems, it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends. In this case, the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. • It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected. When this happens, the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations. The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. 18 victaulic.com 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5.1 PERFORMANCE – FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hoses Style AB1, AB2, AB3, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB12, ABBA and ABMM VicFlex Brackets Length of Stainless Steel Flexible Hose inches/mm K-Factor Imperial/S.I. Outlet Size inches/mm/type Equivalent Length of 1"/33.7 mm Sch. 40 Pipe feet/meters Maximum Number of 90° Bends at 7"/178 mm Bend Radius 31/790 5.6/8.1 ½"/15/Straight 13.8/4.2 2½"/15/90˚ Elbow 23.5/7.1 36/915 5.6/8.1 ½"/15/Straight 16.6/5.1 2½"/15/90˚ Elbow 25.6/7.8 48/1220 5.6/8.1 ½"/15/Straight 23.4/7.1 3½"/15/90˚ Elbow 30.7/9.3 60/1525 5.6/8.1 ½"/15/Straight 30.2/9.2 4½"/15/90˚ Elbow 35.9/10.9 72/1830 5.6/8.1 ½"/15/Straight 37.0/11.3 4½"/15/90˚ Elbow 41.1/12.5 31/790 8.0/11.5 ¾"/20/Straight 16.8/5.1 2¾"/20/90˚ Elbow 16.8/5.1 36/915 8.0/11.5 ¾"/20/Straight 20/6.0 2¾"/20/90˚ Elbow 19.7/6.0 48/1220 8.0/11.5 ¾"/20/Straight 27.8/8.4 3¾"/20/90˚ Elbow 26.6/8.1 60/1525 8.0/11.5 ¾"/20/Straight 35.7/10.9 4¾"/20/90˚ Elbow 33.6/10.2 72/1830 8.0/11.5 ¾"/20/Straight 43.5/13.2 4¾"/20/90˚ Elbow 40.6/12.2 31/790 11.2/16.1 ¾"/20/Straight 16.5/5.0 2¾"/20/90˚ Elbow 17.8/5.4 36/915 11.2/16.1 ¾"/20/Straight 19.5/5.9 2¾"/20/90˚ Elbow 20.7/6.3 48/1220 11.2/16.1 ¾"/20/Straight 26.7/8.1 3¾"/20/90˚ Elbow 27.9/8.5 60/1525 11.2/16.1 ¾"/20/Straight 33.9/10.3 4¾"/20/90˚ Elbow 35/10.7 72/1830 11.2/16.1 ¾"/20/Straight 41.3/12.5 4¾"/20/90˚ Elbow 42.2/12.8 31/790 14.0/20.2 ¾"/20/Straight 14.9/4.5 2¾"/20/90˚ Elbow 15.5/4.72 36/915 14.0/20.2 ¾"/20/Straight 19.4/5.9 2¾"/20/90˚ Elbow 19.6/5.9 48/1220 14.0/20.2 ¾"/20/Straight 30.3/9.2 3¾"/20/90˚ Elbow 29.5/8.9 60/1525 14.0/20.2 ¾"/20/Straight 33.9/10.3 4¾"/20/90˚ Elbow 34.1/10.4 72/1830 14.0/20.2 ¾"/20/Straight 37.5/11.4 4¾"/20/90˚ Elbow 38.6/11.7 FM NOTES: • The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. • EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 19 victaulic.com 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5.2 PERFORMANCE – FRICTION LOSS DATA Series AH2 Braided Hose with 90° Low Profile Elbows Style AB5, AB11, AB12, ABBA and ABMM VicFlex Bracket Length of Stainless Steel Flexible Hose K-Factor Outlet Size Equivalent Length of 1"/33.7mm Sch. 40 Pipe Maximum Number of 90° Bends at 7"/178mm Bend Radius inches/mm Imperial/S.I.inches/mm feet/meters 31/790 5.6/8.1 ½"/15 13.7/4.2 2 36/915 5.6/8.1 ½"/15 17.0/5.2 2 48/1220 5.6/8.1 ½"/15 25.0/7.6 3 60/1525 5.6/8.1 ½"/15 33.0/10.1 4 72/1830 5.6/8.1 ½"/15 41.1/12.5 4 31/790 8.0/11.5 ¾"/20 13.6/4.14 2 36/915 8.0/11.5 ¾"/20 16.9/5.2 2 48/1220 8.0/11.5 ¾"/20 27.8/8.5 3 60/1525 8.0/11.5 ¾"/20 32.6/9.9 4 72/1830 8.0/11.5 ¾"/20 40.6/12.4 4 31/790 11.2/16.1 ¾"/20 13.7/4.2 2 36/915 11.2/16.1 ¾"/20 17.0/5.2 2 48/1220 11.2/16.1 ¾"/20 24.9/7.6 3 60/1525 11.2/16.1 ¾"/20 32.9/10.0 4 72/1830 11.2/16.1 ¾"/20 40.9/12.5 4 31/790 14.0/20.2 ¾"/20 13.5/4.1 2 36/915 14.0/20.2 ¾"/20 16.8/5.1 2 48/1220 14.0/20.2 ¾"/20 24.7/7.5 3 60/1525 14.0/20.2 ¾"/20 32.7/9.9 4 72/1830 14.0/20.2 ¾"/20 40.7/12.4 4 FM NOTES: • The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. • EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 20 victaulic.com 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5.3 PERFORMANCE – FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hose Style AB1, AB2, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB11 and AB12 Brackets Equivalent Length of Maximum Number Length of steel pipe according to of 90º Bends at Stainless Steel Outlet EN 10255 DN 25 3"/76.2 mm Bend Flexible Hose Size (33,7 x 3,25)Radius mm/inches mm/inches meters/feet meters/feet 31/790 15 mm/½"5.5/18.0 320 mm/¾" 36/915 15 mm/½"6.4/21.0 320 mm/¾" 48/1220 15 mm/½"8.5/27.9 320 mm/¾" 60/1525 15 mm/½"10.7/35.1 420 mm/¾" 72/1830 15 mm/½"12.8/42.0 420 mm/¾" VDS CEILING MANUFACTURERS LIST AB1, AB2, AB7, AB10 ,AB11 AB4 AB5, AB8 1. AMF No specific approval 2. Armstrong 3. Chicago Metallic 4. Dipling 5. Durlum 6. Geipel 7. Gema-Armstrong 8. Hilti 9. Knauf 10. Lafarge 11. Linder 12. Odenwald 13. Richter 14. Rigips 15. Rockfon Pagos 16. Suckow & Fischer 17. USG Donn 1. Hilti 2. Knauf 3. Lafarge 4. Lindner 5. Rigips Series AH2 and AH2-CC Braided Hose Style AB1, AB2, AB3, AB4, AB5, AB7, AB8, and AB10 Brackets Series AH2 Braided Hose Style AB1, AB2, AB3, AB4, AB5, AB7, AB8, AB10 and AB12 Brackets Length of Stainless Steel Flexible Hose Outlet Size Equivalent Length of steel pipe according to EN 10255 DN 25 (33,7 x 3,25) Maximum Number of 90º Bends at 3"/76.2 mm Bend Radius mm/inches mm/inches/type meters/feet 790/31 15 mm/½"/Straight 1.8/6.0 220 mm/¾"/Straight 915/36 15 mm/½"/Straight 3.6/11.9 320 mm/¾"/Straight 1220/48 15 mm/½"/Straight 4.3/14.0 320 mm/¾"/Straight 1525/60 15 mm/½"/Straight 4.1/13.6 320 mm/¾"/Straight 1830/72 15 mm/½"/Straight 5.5/18.1 320 mm/¾"/Straight Length of Flexible Equivalent Length of Hose 1"/33.7 mm Sch. 40 Pipe mm inches Straight Configuration Bend Configuration 790 0.87 2.70 31 2.9 8.9 915 1.00 2.80 36 3.3 9.2 1220 2.23 4.66 48 7.3 15.3 1525 2.90 6.5 60 9.5 21.3 1830 3.31 7.16 72 10.9 23.5 CCCF NOTE • Friction loss data is in accordance with GB5135.16 tested at a flow rate of 114 liters per minute (30 gallons per minute). 21 victaulic.com 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 6.0 NOTIFICATIONS WARNING • Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Always verify that the piping system has been completely depressurized and drained immediately prior to installa- tion, removal, adjustment, or maintenance of any Victaulic products. • Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. WARNING • It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. • The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. 22 victaulic.com 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 7.0 REFERENCE MATERIALS – CHARACTERISTICS VicFlex Maximum Load Values Series AH2 Hose with 24" Bracket Actual Length Total Load Max. Uniform Load Model Size ft m lb N lb/linear ft N/linear m 31/790 2.6 0.8 5.2 23 2.6 38 36/915 3 0.9 5.5 25 2.8 40 48/1220 4 1.2 6.3 28 3.1 46 60/1525 5 1.5 7.0 31 3.5 51 72/1830 6 1.8 7.7 34 3.9 57 Series AH2 Hose with 48" Bracket Model Size Actual Length Total Load Max. Uniform Load ft m lb N lb/linear ft N/linear m 31/790 2.6 0.8 6.1 27 1.5 22 36/915 3 0.9 6.4 29 1.6 23 48/1220 4 1.2 7.2 32 1.8 26 60/1525 5 1.5 7.9 35 2.0 29 72/1830 6 1.8 8.7 39 2.2 32 Total Load is defined as the sum of the weights of the following: • water-filled flexible sprinkler hose with threaded end fittings, including a typical fire sprinkler • bracket assembly (any applicable Victaulic bracket model of the relevant associated size) ASTM C 635: Suspension System Load-Carrying Capabilities (excerpted) Actual Length Min. Allowable Uniform Load Suspension System ft/m lb/linear ft N/linear m Direct Hung Light 5.0 75.7 Intermediate 12.0 181.0 Heavy 16.0 241.7 SUMMARY: All direct-hung suspension system duty classifications per ASTM C 635 are able to withstand the maximum water-filled weight of the VicFlex sprinkler hose and bracket. 23 victaulic.com 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products Victaulic products for a particular end-use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications, and the applicable building codes and related Victaulic reserves the right to change product specifications, designs and standard regulations as well as Victaulic performance, maintenance, safety, and warning equipment without notice and without incurring obligations. instructions. Nothing in this or any other document, nor any verbal recommendation, Installationadvice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, Reference should always be made to I-VICFLEX-AB1-AB2-AB10, I-VICFLEX-AB4, or waive any provision of Victaulic Company's standard conditions of sale, installation I-VICFLEX-AB7, or I-VICFLEX-AB8 for the product you are installing. Handbooks are guide, or this disclaimer.included with each shipment of Victaulic products for complete installation and assembly Intellectual Property Rights data, and are available in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warrantyproduct, service, or design is intended, or should be constructed, to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details.under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design, or as a recommendation for the use of such Trademarks material, product, service, or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right. The terms “Patented” or “Patent Pending” refer to design or utility patents Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. 7.0 REFERENCE MATERIALS – CHARACTERISTICS (CONTINUED) Flexible Hose In-Plane Bend Characteristics One Bend Two Bends Three Bends 2X2XMinimum Minimum Minimum bend radius bend radius bend radius OR Minimum OR bend radius 90° Minimum bend radius Minimum Minimum bend radius bend radius Minimum bend radius Minimum bend radius NOTE For out-of-plane (three-dimensional) bends, care must be taken to avoid imparting torque on the hose. I-VicFlex-AB1-AB2-AB10 I-VicFlex-AB3 I-VicFlex-AB4 I-VicFlex-AB7 I-VicFlex-AB8 I-VicFlex-AB12 I-VicFlex-ABBA I-VicFlex-ABMM 24 victaulic.com Size Range:One size fits bracing pipe 1"(25mm)thru 2"(50mm), 12 gauge (2.6mm)channel, and all structural steel up to 1/4"(31.7mm)thick. Material:Steel. Stainless Steel Type 316 (SS6) optional. Function:Multi-functional attachment to structure or braced pipe fitting. Features:This product’s design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2010) 9.3.5.8.4 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation:Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 2002, 4L, 4A or 4B to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install:Place the Fig. 980 onto the "bracing pipe". Tighten the set screw until the head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals:—Underwriters Laboratories Listed in the USA (UL)and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Note:Fig. 980 Swivel Attachment and Fig. 1001, Fig. 1000, Fig. 2002, Fig. 4A, Fig. 4B or Fig. 4L pipe clamps make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association (NFPA) Finish:Plain, Electro-Galvanized or Stainless Steel. Contact customer service for alternative finishes. Order By:Figure number and finish. US Patent Numbers Pat. #6,273,372, Pat. #6,517,030, Pat. #6,953,174, Pat. #6,708,930, Pat. #7,191,987, Pat. #7,441,730, Pat. #7,669,806 Eaton’s B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton, except that, in addition to the other exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton. TOLCO™Fig. 980 - Universal Swivel Sway Brace Attachment - 3/8”-16 to 3/4”-10 rods TOLCO™Fig. 980H - Universal Swivel Sway Brace Attachment - 7/8”-9 to 11/4”-7 rods Component of State of California OSHPD Approved Seismic Restraints System Seismic Bracing* Mounting attachment hole size. ** Installed with 1” or 11/4” Schedule 40 brace pipe. B B D D A A 980 980H Mounting Hardware Is Not Included Set Screw Included Seismic Bracing 186 Eaton All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers & Supports Part Max. Horizontal Max. Horizontal Design Load** (FM)Approx. Number AB D*Design Load (cULus)30°-44° 45°-59° 60°-74° 75°-90° Wt./100 in. (mm) in. (mm) in. (mm) lbs./(kN) lbs./(kN) lbs./(kN) lbs./(kN) lbs./(kN) lbs. (kg) 980-3/8 51/4”(133.3)17/8”(47.6)13/32”(10.3)149 (67.6) 980-1/2 51/4”(133.3)17/8”(47.6)17/32”(13.5)148 (67.1) 980-5/8 51/4”(133.3)17/8”(47.6)11/16”(17.5)147 (66.7) 980-3/4 51/4”(133.3)17/8”(47.6)13/16”(20.5)2015 1320 1970 2310 2550 146 (66.2) 980H-7/8 63/4”(171.4)31/2”(88.9)15/16”(23.8)(8.96)(5.87) (8.76) (10.27) (11.34) 402 (182.3) 980H-1 63/4”(171.4)31/2”(88.9)11/16”(27.0)400 (181.4) 980H-11/8 63/4”(171.4)31/2”(88.9)13/16”(30.2)397 (180.1) 980H-11/4 63/4”(171.4)31/2”(88.9)15/16”(33.3)390 (176.9) * Mounting attachment hole size. ** Installed with 1” or 11/4” Schedule 40 brace pipe. Important! - For load information when using Fig. 980 with pre-installed or post-installed concrete anchors in compliance with NFPA 13 (2016) or ASCE 7-10, including prying factors, see load tables on pages AL1 thru AL21. www.tolco.com Fig. 25 - Surge Restrainer Size Range — One size fits 3/4” thru 2” pipe Material — Pre-Galvanized Steel Function — Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals — Underwriters’ Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish — Pre-Galvanized Order By — Figure number and TOLCO band hanger, size from 3/4” thru 2”. Patent #5,344,108 COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 92 www.tolco.com Revision 12/18/2008 Fig. 200 - “Trimline” Adjustable Band Hanger Fig. 200R (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. • (21⁄2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters’ Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By — Figure number and pipe size Note — Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31⁄8 25⁄8 400 11 3/4 3/8 8mm or 10mm 31⁄8 21⁄2 400 11 1 3/8 8mm or 10mm 33⁄8 25⁄8 400 12 11⁄4 3/8 8mm or 10mm 33⁄4 27⁄8 400 13 11⁄2 3/8 8mm or 10mm 37⁄8 27⁄8 400 14 2 3/8 8mm or 10mm 41⁄2 3 400 15 21⁄2 3/8 10mm 55⁄8 41⁄8 600 27 3 3/8 10mm 57⁄8 4 600 29 31⁄2 3/8 10mm 73⁄8 51⁄4 600 34 4 3/8 10mm 73⁄8 5 1000 35 5 1/2 12mm 91⁄8 61⁄4 1250 66 6 1/2 12mm 101⁄8 63⁄4 1250 73 8 1/2 12mm 131⁄8 83⁄4 1250 136 A B A B A B A B Fig. 200 1" - 2"Fig. 200 21⁄2" - 8" Fig. 200R 21⁄2" - 8"Fig. 200R 1/2" - 2" OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 93 www.tolco.com Fig. 200H - Heavy Duty Band Hanger (for Trapeze) Revision 12/3/2008 Size Range — 2" thru 4" trapeze pipe size. Used to support up to 8" pipe. For 6" and 8" trapeze pipe, consult factory. Material — Carbon Steel — Pre-Galvanized to G40 Spec Function —Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features — Furnished with 3/8" or 1/2" adjusting threaded ring nut. Approvals — Underwriters’ Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Pre-Galvanized Order By — Figure number, pipe size and rod size. Important Design Note — Because of the increased loads applied to the trapeze assem- bly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended*. * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13 (2002) Table 9.1.1.6.1 (a and b). ** All sizes are UL Listed to support up to 8" pipe at max spacing per NFPA 13. B A Dimensions • Weights Trapeze Rod Size **Max. Rec. Pipe Size Size A B Load Lbs. 2 3/8 49⁄16 37⁄32 1250 2 1/2 423⁄32 33⁄8 1250 21⁄2 3/8 55⁄16 323⁄32 1250 21⁄2 1/2 515⁄32 37⁄8 1250 3 3/8 53⁄4 327⁄32 1250 3 1/2 57⁄8 331⁄32 1250 4 3/8 67⁄8 47⁄16 1250 4 1/2 71⁄32 419⁄32 1250 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 94 www.tolco.com Revision 1/24/2007 Fig. 200WON - “Trimline” Adjustable Band Hanger w/o Swivel Nut Size Range — 1/2" thru 8" pipe Material — Carbon Steel Function — Recommended for the suspension of fire sprinkler and non-insulated pipe or insulated pipe with Fig. 220 shield. Generally installed with two hex nuts. Features — Flared edges on sizes 1/2" thru 2". Eases installation and protects CPVC pipe from any abrasion. Approvals — Underwriters’ Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe. Conforms to Federal Specifications WW-171E, Type 7 and Manufacturers Standardization Society SP-69, Type 7 Maximum Temperature — 650°F Finish — Mil. Galvanized to G-90 Note — Available in Stainless Steel materials Order By — Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size A B C Load Lbs. Wt./100 1/2 3/8 21⁄2 2 400 8 3/4 3/8 21⁄2 2 400 8 1 3/8 27⁄8 21⁄8 400 9 11⁄4 3/8 33⁄8 21⁄2 400 10 11⁄2 3/8 31⁄2 21⁄2 400 11 2 3/8 33⁄4 21⁄2 400 12 21⁄2 3/8 51⁄8 35⁄8 600 24 3 3/8 53⁄8 31⁄2 600 27 31⁄2 3/8 63⁄4 45⁄8 600 32 4 3/8 63⁄4 41⁄2 1000 33 5 1/2 83⁄8 51⁄2 1250 60 6 1/2 93⁄8 6 1250 68 8 1/2 123⁄8 8 1250 130 Seismic BracingSize Range:Pipe size to be braced: 1"(25mm)thru 8"(200mm)IPS. * Pipe size used for bracing: 1"(25mm)and 11⁄4"(32mm)Schedule 40 IPS. Material:Steel Function:For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features:Can be used to brace schedules 7 through 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a four-way riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note:Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set screws until heads bottom out. A minimum of 1"(25mm)pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals:Underwriters Laboratories Listed in the USA and Canada (cULus). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines, OPA-0300-10. Finish:Plain or Electro-Galvanized. Contact customer service for alternative finishes and materials. Order By:Indicate pipe size to be braced followed by pipe size used for bracing, figure number and finish. Important Note:Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that Fig. 1001 must be used only with other TOLCO bracing products. TOLCO™Fig. 1001 - Sway Brace Attachment Component of State of California OSHPD Approved Seismic Restraints System Set Screws Included 1 FM Approved when used with 1 or 11/4 inch NPS Schedule 40 GB/T 3091,EN 10255H, or JIS G3451 steel pipe as the brace member. 2 Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as “Schedule 7”. These ratings may also be applied when EN 10220 and GB/T 8163 steel pipe. 3 Load rating for Schedule 10 above may be applied to GB/T 3092,EN 10255M and H, or JIS G3454, FM Approved Thinwall, or Schedule 40 steel pipes. Note: See UL load ratings in UL Listed Design Load chart shown under drawing. Seismic Bracing All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 193 B-Line series Pipe Hangers & SupportsEaton Part Number & Approx. Wt./100 Max. Horizontal Design Load (FM) Pipe For Sch. 7, Sch. 10, & Sch. 40 Pipe 1, 2, 3 Size 1” (24mm)Brace Pipe 11/4” (32mm)Brace Pipe 30°-44° 45°-59° 60°-74° 75°-90° in. (mm)Lbs. (kg)Lbs. (kg) Lbs. (kN) Lbs. (kN) Lbs. (kN) Lbs. (kN) 1”(25)1001-1 X 1 100.0 (45.3)1001-1 X 11/4 118.0 (53.5)1800 (8.00)2550 (11.34)3120 (13.88)3490 (25.52) 11/4”(32)1001-11/4 X 1 100.0 (45.3)1001-11/4 X 11/4 114.0 (51,7)1230 (5.47)1740 (7.74)2140 (9.52)2380 (10.58) 11/2”(40)1001-11/2 X 1 100.0 (45.3)1001-11/2 X 11/4 115.0 (52.1)1230 (5.47)1740 (7.74)2140 (9.52)2380 (10.58) 2”(50)1001-2 X 1 108.0 (49.0)1001-2 X 11/4 121.0 (54.9)1230 (5.47)1740 (7.74)2140 (9.52)2380 (10.58) 21/2”(65)1001-21/2 X 1 138.6 (62.8)1001-21/2 X 11/4 160.4 (72.7)800 (3.56)1130 (5.02)1380 (6.14)1540 (6.85) 3”(80)1001-3 X 1 147.2 (66.7)1001-3 X 11/4 168.7 (76,5)850 (3.78)1200 (5.34)1470 (6.54)1640 (7.29) 4”(100)1001-4 X 1 160.9 (73.0)1001-4 X 11/4 182.4 (82.7)850 (3.78)1200 (5.34)1470 (6.54)1640 (7.29) 6”(150)1001-6 X 1 190.0 (86.2)1001-6 X 11/4 211.4 (95.9)510 (2.27)730 (3.25)890 (3.96)990 (4.40) 8”(200)1001-8 X 1 217.4 (98.6)1001-8 X 11/4 238.8 (108.3)510 (2.27)730 (3.25)890 (3.96)990 (4.40) Pipe Max. Horizontal Design Load (UL) - Lbs. Size For Brace Pipe Size 1” / 1 1/4” Sch. 7 Sch. 10 Sch. 40 in. (mm)1” / 11/4” 1” / 1 1/4” 1” / 1 1/4” 1”(25)-- / -- 1000 / 1000 1000 / 1000 11/4”(32)1000 / 1000 1000 / 1000 1000 / 1000 11/2”(40)1000 / 1000 1500 / 1500 1500 / 1500 2”(50)1000 / 1000 2015 / 2015 2015 / 2015 21/2”(65)1600 / 1600 2015 / 2765 2015 / 2765 3”(80)1600 / 1600 2015 / 2765 2015 / 2765 4”(100)1600 / 1600 2015 / 2765 2015 / 2765 6”(150)1600 / 1600 2015 / 2765 2015 / 2765 8”(200)1600 / 1600 2015 / 2765 2015 / 2765 Size Range:Pipe size to be braced: 21⁄2"(65mm)thru 8"(200mm)all steel schedules, copper, plastic, FRP, cast iron and ductile iron. Consult factory when bracing other than steel. The Fig. 2002 accepts brace pipes sizes 11⁄2"(40mm)and 2"(50mm)steel schedule 10 through schedule 40. Material:Steel Function:For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 2002 is used in conjunction with a TOLCO 900 Series sway brace attachments and joined together with bracing pipe. Install per NFPA 13 and/or TOLCO State of California OSHPD Approved Seismic Restrain Manual. Features:Unique design will not damage thin wall, plastic, copper or ductile iron pipe. Easy verification of proper installation by tightening bolts until ears touch. Installation:Place Fig. 2002 over pipe to be braced. Slide bracing pipe through attachment and tighten hex nuts until ears touch. Approvals:Underwriters Laboratories Listed in the USA (UL)and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish:Plain. Contact customer service for alternative finishes and materials. Order By:Figure number, pipe size to be braced, pipe size used for bracing (11⁄2"(40mm)or 2"(50mm)) and finish. Important Note:Fig. 2002 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that the Fig. 2002 must be used only with other TOLCO bracing products. TOLCO™Fig. 2002 - Sway Brace Attachment UL Listed Design Load 2015 lbs. (8.96kN) Component of State of California OSHPD Approved Seismic Restraints System Shown with Fig. 980 1” (25.4mm) Min.Seismic Bracing** See load ratings in UL Listed Design Load chart. Hardware Included Seismic Bracing 194 Eaton All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers & Supports Pipe Part Number & Approx. Wt./100 Max. Horizontal Size 11/2” (32mm)Brace Pipe 2” (50mm)Brace Pipe Design Load (UL) in. (mm)Lbs. (kg)Lbs. (kg) Lbs. (kg) 21/2”(65)2002-21/2 X 11/2 224.9 (102.0)2002-21/2 X 2 283.3 (128.6)2015 (8.96) 3”(80)2002-3 X 11/2 241.0 (109.3)2002-3 X 2 299.4 (135.8) 2015 (8.96) 4”(100)2002-4 X 11/2 268.4 (121.7)2002-4 X 2 326.8 (148.2) 2015 (8.96) 6”(150)2002-6 X 11/2 326.6 (148.1)2002-6 X 2 385.0 (174.6) 2015 (8.96) 8”(200)2002-8 X 11/2 381.3 (172.9)2002-8 X 2 439.7 (199.4) 2015 (8.96) TOLCO™Fig. 4L - Longitudinal “In-Line” Sway Brace Attachment Size Range:2" (50mm)through 8" (200mm)IPS. Material:Steel Function:For bracing pipe against sway and seismic disturbance. Approvals:Underwriters Laboratories Listed in the USA (UL)and Canada (cUL)21/2" (65mm)through 8" (200mm)pipe. Approved by Factory Mutual Engineering (FM), 21/2" (65mm)through 8" (200mm)pipe. Installation Instructions:Fig. 4L is the "braced pipe" attachment component of a longitudinal sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install:Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage "bracing pipe" into jaw opening and tighten set screw until head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish:Plain. Contact customer service for alternative finishes and materials. Order By:Figure number, pipe size and finish. Eaton’s B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton, except that, in addition to the other exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton.Seismic BracingC AD * The loads listed are axial loads on the brace. The horizontal load capacity, H, of the brace is: H = F x sin ?, where ? the installation angle measured from the vertical. FM approved when used with 1", 11⁄4", 11⁄2" or 2" Sch. 40 brace pipe. Longitudinal Brace 4-Way Riser Brace (plan view) Set Screw & Hardware Included Seismic Bracing 174 Eaton All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers & Supports Pipe Max. Horizontal Approx. Part Size ACDBolt Size Design Load (cULuc) Wt./100 No.in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg) 4L-21/2 21/2"(65)67/16"(163.5)21/2"(63.5)23/4"(69.8)1/2"-13 2015 (8.96)253 (114.7) 4L-3 3"(80)7"(177.8)23/4"(69.8)31/16"(77.8)1/2"-13 2015 (8.96)268 (121.5) 4L-4 4"(100)81/2"(215.9)33/8"(85.7)311/16"(93.7)1/2"-13 2015 (8.96)348 (157.8) 4L-5 5"(125)93/4"(247.6)37/8"(98.4)43/8"(111.1)1/2"-13 2015 (8.96)380 (172.3) 4L-6 6"(150)111/2"(292.1)5"(127.0)51/8"(130.2)1/2"-13 2015 (8.96)640 (290.3) 4L-8 8"(200)131/4"(336.5)55/8"(142.8)55/8"(142.8)1/2"-13 2015 (8.96)728 (330.2) Pipe Max. Horizontal Max. Horizontal Design Load (FM) Part Size Design Load (cULuc) 30-44° 45-59° 60°-74° 75°-90° No.in. (mm)lbs./(kN)lbs./(kN) lbs./(kN lbs./(kN) lbs./(kN) 4L-21/2 21/2"(65)2015 (8.96)1030 (4.58)1180 (5.24)1420 (6.31)1590 (7.07) 4L-3 3"(80)2015 (8.96)1030 (4.58)1180 (5.24)1420 (6.31)1590 (7.07) 4L-4 4"(100)2015 (8.96)530 (2.36)730 (3.25)890 (3.96)990 (4.40) 4L-5 5"(125)2015 (8.96) 530 (2.36)730 (3.25)890 (3.96)990 (4.40) 4L-6 6"(150)2015 (8.96) 530 (2.36)730 (3.25)890 (3.96)990 (4.40) 4L-8 8"(200)2015 (8.96)490 (2.18)680 (3.02)830 (3.69)930 (4.13) Size Range:1" (25mm)through 12" (300mm)IPS. Material:Steel Function:For bracing pipe against sway and seismic disturbance. Approvals:Approved by Factory Mutual Engineering (FM), 1" (25mm) through 12" (300mm)pipe. Underwriters Laboratories Listed in the USA and Canada (cULus), 1" (25mm)through 10" (250mm)pipe. See allowable loads in charts on page 172. Installation Instructions:Fig. 4LA can be used as the system attachment component of a longitudinal or lateral brace assembly. It is intended to be combined with the "bracing member" and TOLCO transitional attachment and structural attachment to form a complete bracing assembly. For fire sprinkler applications NFPA 13 guidelines should be followed. To Install:Place the Fig. 4LA pipe clamp component over the pipe to be braced and tighten down the break-off nuts until the hex head portion breaks off to verify correct installation torque. Next engage brace member (pipe or strut) with jaw component and tighten break-off head bolt until the hex head breaks off to verify correct installation torque. Pivot jaw for correct angle and attach to structure using TOLCO brand transitional attachment and structural attachment. Finish:Plain or Electro-Galvanized. Contact customer service for alternative finishes and materials. Order By:Figure number, pipe size and finish. TOLCO™Fig. 4LA - Longitudinal “In-Line” Sway Brace Attachment Eaton’s B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton, except that, in addition to the other exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton.Seismic BracingC A D 4LA-1 thru 4LA-4 4LA-6 thru 4LA-12 C AD Seismic Bracing All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 175 B-Line series Pipe Hangers & SupportsEaton Pipe Approx. Part Size ACDBolt Size Wt./100 No.in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) 4LA-1 1"(25)319/32"(91.2)15/16"(33.5)15/16"(33.5)3/8"-16 119 (54.0) 4LA-11/4 11/4"(32)329/32"(99.3)13/8"(35.3)13/8"(35.3)3/8"-16 123 (55.8) 4LA-11/2 11/2"(40)45/32"(105.7)11/2"(38.5)11/2"(38.5)3/8"-16 127 (57.6) 4LA-2 2"(50)511/32"(135.6)21/32"(51.9)21/16"(51.9)3/8"-16 142 (64.4) 4LA-21/2 21/2"(65)527/32"(148.7)25/16"(58.5)25/16"(58.5)3/8"-16 173 (78.5) 4LA-3 3"(80)61/2"(164.9)25/8"(66.6)25/8"(66.6)3/8"-16 187 (84.8) 4LA-4 4"(100)717/32"(191.3)31/8"(79.5)31/8"(79.5)3/8"-16 209 (94.8) 4LA-6 6"(150)105/8"(269.9)49/16"(115.9)49/16"(115.9)1/2"-13 521 (236.3) 4LA-8 8"(200)1213/16"(325.5)59/16"(143.7)521/32"(143.7)1/2"-13 629 (285.3) 4LA-10 10"(250)161/2"(419.1)71/4"(184.2)71/4"(184.2)1/2"-13 1320 (598.7) 4LA-12 12"(300)181/2"(469.9)81/4"(209.6)81/4"(209.6)1/2"-13 1496 (678.6) TOLCO™Fig. 4LA - Longitudinal “In-Line” Sway Brace Attachment cont.Seismic BracingLongitudinal Brace Lateral Brace Eaton’s B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton, except that, in addition to the other exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton. Seismic Bracing 176 Eaton All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers & Supports Longitudinal Loads Max. Horizontal Design Load (FM)Max. Horizontal Part Pipe Size 30°-44° 45°-59° 60°-74° 75°-90° Design Load (UL) No.in. (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) 4LA-1 1"(25)680 (3.02)970 (4.31)1190 (5.29)1320 (5.87)1000 (4.45) 4LA-11/4 11/4"(32)680 (3.02)970 (4.31)1190 (5.29)1320 (5.87)1000 (4.45) 4LA-11/2 11/2"(40)680 (3.02)970 (4.31)1190 (5.29)1320 (5.87)1000 (4.45) 4LA-2 2"(50)680 (3.02)860 (3.82)1030 (4.58)1150 (5.11)1000 (4.45) 4LA-21/2 21/2"(65)680 (3.02)970 (4.31)1190 (5.29)1320 (5.87)1000 (4.45) 4LA-3 3"(80)680 (3.02)970 (4.31)1190 (5.29)1320 (5.87)1000 (4.45) 4LA-4 4"(100)680 (3.02)970 (4.31)1190 (5.29)1320 (5.87)1000 (4.45) 4LA-6 6"(150)1620 (7.20)2,260 (10.05)2010 (8.94)2220 (9.87)1600 (7.11) 4LA-8 8"(200)1620 (7.20)1,660 (7.38)1570 (6.98)1740 (7.74)2015 (8.96) 4LA-10 10"(250)1620 (7.20)1,660 (7.38)1570 (6.98)1740 (7.74)NA (NA) 4LA-12 12"(300)1620 (7.20)1,660 (7.38)1570 (6.98)1740 (7.74)NA (NA) Lateral Loads Max. Horizontal Design Load (FM)Max. Horizontal Part Pipe Size 30°-44° 45°-59° 60°-74° 75°-90° Design Load (UL) No.in. (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) 4LA-1 1"(25)680 (3.02)970 (4.31)1190 (5.29)1320 (5.87)NA (NA) 4LA-11/4 11/4"(32)680 (3.02)970 (4.31)1190 (5.29)1320 (5.87)NA (NA) 4LA-11/2 11/2"(40)680 (3.02)970 (4.31)1190 (5.29)1320 (5.87)NA (NA) 4LA-2 2"(50)680 (3.02)970 (4.31)1190 (5.29)1320 (5.87)NA (NA) 4LA-21/2 21/2"(65)680 (3.02)970 (4.31)1190 (5.29)1320 (5.87)NA (NA) 4LA-3 3"(80)680 (3.02)970 (4.31)1190 (5.29)1320 (5.87)1000 (4.45) 4LA-4 4"(100)680 (3.02)970 (4.31)1190 (5.29)1320 (5.87)1000 (4.45) 4LA-6 6"(150)1620 (7.20)2,300 (10.23)2820 (12.54)3140 (13.96)1600 (7.11) 4LA-8 8"(200)1620 (7.20)2,300 (10.23)2820 (12.54)3140 (13.96)2015 (8.96) 4LA-10 10"(250)1620 (7.20)2,300 (10.23)2820 (12.54)3140 (13.96)NA (NA) 4LA-12 12"(300)1620 (7.20)2,300 (10.23)2820 (12.54)3140 (13.96)NA (NA) TOLCO™ Fig. 76 & Fig. 77 Branch Line Restraint Installation Instructions Fig. 76 – Structural Attachment for Restraint (Sway Brace) Assembly The required type, number and size of fasteners used for the structure attachment fitting shall be in accordance with NFPA 13. • Accommodates 3⁄8" (9.5mm) or ½" (12.7mm) standard all thread rod (ATR) as the restraint (brace) member, refer to NFPA 13 (2013) Table 9.3.5.11.8 (a)(b) & (c) for allowable brace lengths. • Multiple holes to allow various fasteners to attach to the structure. – Larger hole accommodates 3⁄8" (9.5mm) fastener – Two smaller holes accommodate #10 fastener • Can be field bent to accommodate angles from 15° to 90° from the mounting surface. Fig. 77 – System Piping Attachment for Restraint (Sway Brace) Assembly • Accommodates 3⁄8" (9.5mm) or ½" (12.7mm) standard all thread rod (ATR) as the restraint (brace) member, refer to NFPA 13 for allowable brace length. • UL Listed for Steel Sch. 10, 40 and light wall engineered pipe and plastic CPVC pipe.§ • FM Approved for Steel Sch. 10, 40 and light wall engineered pipe. B-LINE SERIES Fig. 76 & Fig.77 assembly Fig.76 Fig.77 up Fig.76 down Fig.77 down UL Listed as a hanger in this application only. Must be completely bent open and only with 3⁄8" ATR to accomodate up to 4" (100mm) maximum pipe size. Fig. 76 Restraint application.Hanger application. Restraint (Sway Brace) Assembly SEIS-17 Follow us on social media to get the latest product and support information. B-Line Division 13201 Dahlia Street, Suite 200 Fontana, CA 92337 United States Phone: 800-851-7415 www.cooperbline.com/tolco Eaton is a registered trademark. All other trademarks are property of their respective owners. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com © 2017 Eaton All Rights Reserved Printed in USA Publication No. IL309002EN May 2017 SEIS-17 Recommended Installation Method: Step 1: Install all thread rod (brace member) to TOLCO™ Fig. 76 Structural Attachment. Bottom out ATR to ensure full thread engagement. This can be visually confirmed due to the open thread design. Step 2: Install TOLCO™ Fig. 77 System Attachment to sprinkler pipe branch line to be restrained. You can position with the rod engagement either above or below the sprinkler pipe. Rod must extend a min. of 1" (25.4mm) past the edge of the Fig. 77. The attachment can be slid along the pipe to position close to where the Fig. 76 structural attachment will be fastened to the structure. The snap on design allows maximum adjustability during this stage of the installation process. Can be field bent to accommodate angles from 15° to 90° from the mounting surface. The product shall not be bent more than three times to prevent material fatigue. (See Detail A & B at right). Step 3: Engage ATR (previously attached to the Fig. 76 Structural Attachment to the rod engagement portion of the Fig. 77 System Attachment. DO NOT tighten the set bolt at this time. Step 4: Install Fig. 76 Structural Attachment to the building structure. Follow fastener manufacturer and NFPA 13 guidelines to install appropriate fastener for the structural type (i.e. concrete, wood, steel). Step 5: Tighten set bolt on Fig. 77 System Attachment until head breaks off verifying proper installation torque. § When installing Fig. 77 to plastic (CPVC) pipe do NOT use power tools to tighten the break-off head set bolt as this may cause damage to the plastic pipe. All Thread Rod Maximum Restraint Lengths Rod Root Least Radius of Gyration Maximum Unbraced Length (L) - in/Max. Horizontal Load @ 45° (lbs.)** Size (in)Dia. (in)r (in)l/r=100 l/r=200 l/r=300 l/r=400† 3⁄8 0.300 0.075 7/(300)14/(186)22/(82)30/(44) 1/2 0.404 0.101 10/(300)‡20/(300)‡30/(152)40/(85) † l/r = 400 NFPA 13 2010, Sec 9.3.6.1 (5) † l/r = 400 NFPA 13 2013,Sec 9.3.6.1 (5) ** Per NFPA 13 (2013) Table 9.3.5.11.8 (a)(b)(c); for additional load information at various other angles see this table. ‡Max load governed by Fig. 76/77 Max horizontal load. UL Listed Maximum Allowable Loads (Horizontal) Product Sch. 10, Sch. 40, Dynaflow & CPVC 3/8" Rod 1/2" Rod (9.5mm) (12.7mm) Fig. 76 300 lbs. 300 lbs. (1.344 kN) (1.344 kN) Fig. 77 – 1" (25.4)300 lbs. 300 lbs. (1.344 kN) (1.344 kN) Fig. 77 – 1¼" (31.75)300 lbs. 300 lbs. (1.344 kN) (1.344 kN) Fig. 77 – 11/2" (38.1)300 lbs. 300 lbs. (1.344 kN) (1.344 kN) Fig. 77 – 2" (50.8)300 lbs. 300 lbs. (1.344 kN) (1.344 kN) FM Approved* Maximum Allowable Loads Product 30° - 44° 3/8" Rod 1/2" Rod (9.5mm) (12.7mm) 45° - 59° 3/8" Rod 1/2" Rod (9.5mm) (12.7mm) 60° - 74° 3/8" Rod 1/2" Rod (9.5mm) (12.7mm) 75° - 90° 3/8" Rod 1/2" Rod (9.5mm) (12.7mm) Fig. 76 380 420 (1.69 kN) (1.87 kN) 530 580 (2.36 kN) (2.58 kN) 800 1,020 (3.56 kN) (4.54 kN) 750 1,110 (3.34 kN) (4.94 kN) Fig. 77 – 1" (25.4)140 160 (.623 kN) (.712 kN) 200 230 (.890 kN) (1.02 kN) 250 280 (1.11 kN) (1.25 kN) 280 320 (1.25 kN) (1.42 kN) Fig. 77 – 1¼" (31.75)140 170 (.623 kN) (.756 kN) 200 250 (.890 kN) (1.11 kN) 250 300 (1.11 kN) (1.33 kN) 280 340 (1.33 kN) (1.51 kN) Fig. 77 – 11/2" (38.1)130 160 (.578 kN) (.712 kN) 190 230 (.845 kN) (1.02 kN) 230 280 (1.02 kN) (1.25 kN) 260 320 (1.29 kN) (1.42 kN) Fig. 77 – 2" (50.8)120 150 (.534 kN) (.667 kN) 170 210 (.756 kN) (.934 kN) 210 260 (.934 kN) (1.29 kN) 240 290 (1.07 kN) (1.29 kN) *Approved for Sch. 10, Sch. 40, Dynaflow, Eddy flow. Marks shown are property of their respective owners. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer’s installation instructions. • Fig. 76 can be bent from the 45° angle it is supplied with, up to a maximum of 45° downward to allow an installation with the rod perpendicular to the mounting surface. (Detail A) • Fig. 76 can be bent from the 45° angle it is supplied with, up to a maximum of 30° upward to allow an installation with the rod at a 15° angle from the mounting surface. (Detail B) • The same bending angles apply to a side mount application. • A bend is defined as one direction within the limits shown in details A & B above. The Fig. 76 may be bent to accommodate the desired angle within the specified limits no more than three times. Excess bending may cause material fatigue and jeopardize the integrity of the part. • These bending requirements apply to the installation of the Fig. 76 as both as a component of a branch line restraint or component of a hanger assembly. 45.00° 45.00° 90.00° 30.00° 45.00° 15.00° Detail A Detail B 4 For the most up to date information, visit www.itwbuildex.com Wood Flooring Wood Joist Double Sheetrock Ceiling Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Box Qty Case Qty VERTICAL MOUNT 1/4" 8002957 GST 100 1/4 x 1"210 (7/16” OSB) 670 (3/4” Ply)25 125 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 1/4" 8004957 GST 300 1/4 x 3" 2060 (Fir) 25 125 3/8" 8007957 GST 10 1/4 x 1" 210 (7/16” OSB) 670 (3/4” Ply)300 25 125 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 3/8" 8068925 GST 20-SS 1/4 x 2" 1760 (Fir) 850 25 125 3/8" 8009925 GST 25-380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) 1500 1475 25 125 3/8" 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25 125 3/8" 8011925 GST 40 1/4 x 4" 2180 (Fir) 25 125 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125 1/2" 8014925 GST 2.5-380 3/8 x 2-1/2" 2113 (Fir) 25 125 1/2" 8015925 GST 3 1/4 x 3" 2275 (Fir) 25 125 Not less than 2” nominal width (1-1/2”) Not less than 3” nominal thickness (2-1/2”) (depth or side of vertical member) #14 Black Nut Driver Part # 8113910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. #14 SW Red Nut Driver Part # 8114910 Composite / Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for GST 25-380 . Tool available on page 11. For vertical use - install in center of lower face. Minimum 2” embedment into base material for NFPA 13 compliance. • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation costs. • Made in the U.S.A. SAMMYS® FOR WOOD Application Product Features Watch a video demonstration atwww.itwbuildex.com SAMMYS® FOR WOOD - Vertical Application Office/Manufacturing facility • 1375 SampSon ave. • Corona, Ca 92879 • ph: 951.737.5599 • Fax: 951.737.0330 custOMer service • 800.786.5266 www.tolco.com 38 www.tolco.com Revision 12/11/2009 Size Range — 3/4" thru 3" CPVC pipe Material — Pre-Galvanized Steel Function — Intended to perform as a hanger/restrainer to support CPVC piping used in automatic fire sprinkler systems. Fig. 23 can be installed on the top, bottom or side of a beam. The Fig. 23 also functions as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL) sizes 3/4" thru 2" to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge steel using (2) 1/4" x 1" tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features — Fig. 23 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. It also incorporates snap restrain- ers allowing easier and faster installation. Easily attaches to the building structure using the two UL Listed hex head self thread- ing screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish — Pre-Galvanized Order By — Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Fig. 23 - Hanger for cpvc plastic pipe double Fastener Strap type dimensions • Weights cpvc Max. Hanger Fastener Hex Approx. pipe Size A B c Spacing (Ft.) Head Size Wt./100 3/4 31⁄8 19⁄16 13⁄16 51⁄2 5/16 9 1 33⁄8 111⁄16 13⁄16 6 5/16 9 11⁄4 43⁄16 23⁄32 13⁄16 61⁄2 5/16 11 11⁄2 47⁄16 27⁄32 13⁄16 7 5/16 12 2 47⁄8 27⁄16 13⁄16 8 5/16 15 21/2 109/32 211/16 13/16 Consult Factory 5/16 22 3 117/8 3 13/16 Consult Factory 5/16 25 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 39 www.tolco.com Dimensions • Weights CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size Wt./100 3/4 25⁄16 15⁄32 13⁄16 51⁄2 5/16 9 1 25⁄8 15⁄16 13⁄16 6 5/16 9 11⁄4 3 11⁄2 13⁄16 61⁄2 5/16 11 11⁄2 31⁄4 15⁄8 13⁄16 7 5/16 12 2 311⁄16 127⁄32 13⁄16 8 5/16 15 Size Range — 3/4" thru 2" CPVC pipe Material — Pre-Galvanized Steel Function — Intended to perform as a hanger/restrainer to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 24 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features — Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a ham- mer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish — Pre-Galvanized Order By — Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Fig. 24 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type - Side Mount Revision 10/24/2007 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 42 www.tolco.com Revision 6/2/2009 Fig. 28M - Offset Hanger and Restrainer for CPVC Plastic Pipe and IPS Pipe Size Range — 3/4" thru 1-1/4" pipe Material — Carbon Steel, Electro-Galvanized Function — Designed to be used as a hanger and restrainer for CPVC piping where the “stand-off” design will ease installation by eliminating the need for wood blocking Features — • Flared edge design protects CPVC pipe from any rough or abrasive surfaces • Unique snap-on design holds pipe firmly in place and allows retrofit type of installation • The “Stand-Off” design eliminates the need for wood block extension • Can be installed on horizontal or vertical piping regardless of mounting surface orientation • Attaches easily to wood structure with two hex head self-threading screws furnished with product • Installs easily using rechargeable electrical driver with 5/16” extension socket eliminating impact tool damage to pipe • Attaches easily to steel, minimum 18 gauge with (2) 1/4” x 1” tek type self drilling tapping screws • cULus Listed as a hanger and a restrainer for fire sprinkler piping Approvals — Underwriters’ Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fas- teners screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28M satisfies the UL vertical restraint requirements where needed. Order By — Figure number and pipe size A C B RESTRAINT PATENT PENDING RESTRAINT Dimensions • Weights Max. Spacing Pipe required per Approx Size A B C NFPA 13 for Wt./100 CPVC plastic pipe 3/4 2 3/16 3-1/2 5’-6” 9 1 2-1/8 3/16 3-1/2 6’-0” 12 1-1/4 2-5/16 3/16 3-1/2 6’-6” 13 Fig. 28M OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 35 www.tolco.com Revision 12/15/2008 Size Range — Secures 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to hanger rod for vertical seismic bracing. Approvals — Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish — Electro Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number Fig. 98 - Rod Stiffener Fig. 98B - Rod Stiffener w/Break-off Bolt Head Fig. 99 - All Thread Rod Cut to Length Size Range — Secures 3/8" thru 7/8" rod in 1" increments Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter, rod length and finish Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F Wt./100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11⁄4 9500 360 11⁄2 13800 510 Dimensions • Weights Component of State of California OSHPD Approved Seismic Restraints System Size Range — Secures 3/8" thru 11⁄2" rod in 10’ lengths Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Dimensions Rod Max. Rec. Load Lbs. Size For Service Temp 650°F 3/8 730 1/2 1350 5/8 2160 3/4 3230 7/8 4480 Fig. 100 - All Thread Rod Full Length FIG. 98B FIG. 98 System No. W-L-1392 SECTION A-A WL 1392Page: 1 of 2 A Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. August 30, 2005 F Ratings - 1 and 2 Hr (See Item 1) T Rating - 0 Hr L Rating At Ambient - Less Than 1 CFM/Sq Ft L Rating At 400°F - 4 CFM/Sq Ft A 1A 4A 1B2 3 4B4B 2 3 C CLAS S IFI E DClassified by Underwriters Laboratories, Inc. to UL 1479 and CAN/ULC-S115 US Page: 2 of 2 1. Wall Assembly — The 1 or 2 hr fire-rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner described in the individual U400 or V400 Series Wall or Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs — Wall framing shall consist of min 3-5/8 in. (92 mm) wide steel studs spaced max 24 in. (610 mm) OC. B. Gypsum Board* — Min 5/8 in. (16 mm), gypsum board. Max diam of opening shall is 16 in. (406 mm). The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. 2. Steel Sleeve — Nom 16 in. (406 mm) diam (or smaller) Schedule 40 (or lighter) steel sleeve friction fitted into opening. Length of steel sleeve to be equal to the thickness of wall. 3. Through Penetrants — One metallic pipe, tubing or conduit to be installed concentrically or eccentrically within opening. The annular space between the pipes and conduits and the edges of the opening shall be min 0 in. (0 mm, point contact) to max 3-7/8 in. (98 mm). Through penetrant to be rigidly supported on both sides of wall assembly. The following types and sizes of through penetrants may be used: A. Steel Pipe — Nom 12 in. (305 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe — Nom 12 in. (305 mm) diam (or smaller) cast or ductile iron pipe. C. Copper Tubing — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tube. D. Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. E. Conduit — Nom 6 in. (152 mm) diam (or smaller) electrical metallic tubing (EMT) or rigid steel conduit. 4. Firestop System — The firestop system shall consist of the following: A. Packing Material — In 2 hr rated wall assemblies, min 5-1/8 in. (130 mm) thickness of min 4 pcf (64 kg/m3) mineral wool batt insulation firmly packed into opening as a permanent form. In 1 hr rated wall assemblies, min 3-7/8 in. (130 mm) thickness of min 4 pcf (64 kg/m3) mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be recessed from both surfaces of wall to accommodate the required thickness of fill material. B. Fill Void or Cavity Materials* — Sealant — Min 1/2 in. (13 mm) thickness of fill material applied within the annulus, flush with both surfaces of wall. Min 1/4 in. (6 mm) diam bead of fill material applied to the through penetrant/steel sleeve interface at the point contact locations on both sides of the wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-ONE Sealant *Bearing the UL Classification Mark System No. W-L-1392 WL 1392F Ratings - 1 and 2 Hr (See Item 1) T Rating - 0 Hr L Rating At Ambient - Less Than 1 CFM/Sq Ft L Rating At 400°F - 4 CFM/Sq Ft Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. August 30, 2005 C CLAS S IFI E DClassified by Underwriters Laboratories, Inc. to UL 1479 and CAN/ULC-S115 US SUBMITTAL SHEET USG Interior Panel & Finishing Solutions USG SHEETROCK® BRAND ACOUSTICAL SEALANT Makes promised ratings a reality • Excellent sound-fl anking material (supports high STC ratings) • Superior performance as a fi re caulk in UL Classifi ed joint and through-penetration fi restop systems • Ideal for use in smoke and/or sound assemblies • Meets ASTM C834 specifi cations for latex sealants • Grade 0°F (-18°C)low temperature fl exibility, strong bond • Low VOC USG Sheetrock® Brand Acoustical Sealant is an acrylic, latex-based sound caulk for use as a sealant in fi re-rated partitions, smoke barriers and sound-rated assemblies. HW-D-0262 – Conventional Wall HW-D-0603 – Shaft Wall Stud USG Sheetrock® Brand Gypsum Panels USG Sheetrock® Brand Gypsum Panels USG Sheetrock® Brand Acoustical Sealant Ceiling runner Floor USG Sheetrock® Brand Gypsum Liner PanelUSG Sheetrock® Brand GypsumPanels USG Sheetrock® Brand Acoustical Sealant J-runner Floor Conventional Wall: BW-S-0013, BW-S-0016, BW-S-0022, BW-S-0026, HW-D-0001, HW-D-0002, HW-D-0262, HW-D-0372, HW-D-0504, HW-D-0506, HW-D-0515, HW-D-0513, HW-D-0518, HW- D-0525, HW-D-0577, HW-D-0584, HW-D-0603, HW-D-0609, HW-D-0610, HW-D-0611, HW-D- 0613, HW-D-0626, HW-D-0627, HW-D-0628, HW-D-1110, HW-S-0009, HW-S-0010, HW-S-0032, HW-S-0035, HW-S-0089, HW-S-0094, HW-S-0096, HW-S-0097, HW-S-0098, HW-S-0099, HW- S-0100, HW-S-0101, WW-S-0058, WW-S-0062 Shaft Wall: HW-D-0603, HW-D-0609, HW-D-0610, HW-D-0611, HW-D-0612, HW-D-0613, BW-S-0016 C-AJ-1020, W-L-1064 and W-L-1087 Versatile: Easily applied on vertical and horizontal surfaces without sagging, even overhead. Sound Tested: As an integral component to maintain high STC/MTC ratings in partitions. Surface-Burning Characteristics: Classifi ed by UL with fl ame spread of 0 and smoke developed of 0. For Use in Fire-Resistant, Sound and Smoke Partitions: Acceptable for use at the perimeter of most wood- and steel-stud wall assemblies. Remains Flexible: Dries tough but stays resilient to “give” with movement. High Adhesion: Bonds tenaciously to a variety of surfaces. Attractive Appearance: Product is nonstaining. Easy to Dispense: Good working properties ensure fast, effi cient application with hand-gun equipment. Excellent Physical Properties: Won’t sag on vertical surfaces; good open time; long shelf life. Easy Cleanup: Latex-based for cleanup with soap and water before drying. UL Classifi ed As: A material for use as a fi ll, void or cavity in fi re-resistant joint and through- penetration fi restop systems. DESCRIPTION UL SYSTEMS JOINT SYSTEMS THROUGH-PENETRATION FIRESTOP SYSTEMS ADVANTAGES DESCRIPTIONDESCRIPTION 1. Not to be applied to moist areas where frost or condensation is present or in direct contact with water. 2. Protect container from freezing and extreme heat. 3. Maintain 55°F (13°C) minimum temperature within the building during and after installation. 4. Product should be stored at a temperature neither below 41°F (5°C) nor exceeding 80°F (26.7°C). 5. Not to be used in applications where the surrounding materials (partitions, floors, penetrations, etc.) will exceed sustained temperatures of 125°F (52°C). 6. Not for use with CPVC or PVC products. 7. For through wall penetration designs where piping is installed either concentrically or eccentrically within a cylindrical sleeve application, the design professional shall specify, at least, 1) A “vented” sleeve that allows egress of moisture from the sleeve module; 2) A spacer, packing material, or backer rod that is compatible, non-reactive, and/or non-conductive between the cylindrical outer sleeve and pipe material. The spacer, packing material, or backer rod shall also serve the function of preventing the pipe material from contacting the outer sleeve material. 8. Consult with manufacturer of adjoining materials for compatibility. 9. Not intended to be painted. Sealant will shrink during curing process. 10. Do not apply USG Sheetrock® Brand Acoustical Sealant in areas where abuse or abrasion of a sealant is likely. 11. There may be discoloration of sealant when in contact with certain types of metal such as copper. Before handling, read Safety Data Sheet and product label for safe usage and health information. Installation of USG Sheetrock® Brand Acoustical Sealant should not begin until building is enclosed and building temperatures are maintained at 55°F (13°C) minimum. Provide adequate ventilation to carry off excess moisture to insure adequate drying. The performance and adhesion of sealants will be only as good as the surface of which it is applied. Surfaces of the opening and any penetration items to be caulked must be sound, clean, dry and free of dust, debris and moisture to insure proper adhesion. USG Sheetrock® Brand Acoustical Sealant shall be applied in accordance with ASTM C919 using conventional caulking equipment. In joint and firestop systems, apply the USG Sheetrock® Brand Acoustical Sealant to minimum thickness specified in the individual fire-rated system. In shaftwall applications, the maximum separation between bottom of floor and top of liner panel is 1" (25mm). Maximum separation between bottom of floor and top of gypsum board sheets at time of installation of joint system is 5/8" (16mm). The joint system is designed to accommodate a maximum 25% compression or extension from its installed width on the finished side of the wall. For all other joints, the sealant application should be specified by a design professional who should give consideration to using a backer rod or bond tape where the gap exceeds 5/8". For through-wall penetration designs where piping is installed either concentrically or eccentrically within a cylindrical sleeve application, the design professional shall specify a spacer, packing material, or backer rod that is compatible / non-reactive with both cylindrical outer sleeve and pipe material. The space, packing material, and backer rod shall also serve the function of preventing pipe from contact with the outer sleeve. In joints too shallow to take a backer rod, use a bond breaker tape to prevent three-sided adhesion. In acoustical applications, apply 1/4" (6mm) minimum. bead of sealant to seal perimeter of partition. Apply continuous bead of USG Sheetrock® Brand Acoustical Sealant around all openings and partition intersections. In penetration applications that are not covered in an individual fire- rated system, the thickness of the sealant applied within the opening should be no less than 1/4" and no greater than 5/8" flush with the top surface of the floor or sides of the wall. Do Don't Do DO USG Sheetrock® Brand Acoustical Sealant USG Sheetrock® Brand Acoustical Sealant Sound pathSteel runner Wall Panels DON'T Electrical outlets LIMITATIONS DIRECTIONS PREPARATION APPLICATION 800 USG.4YOU 800 (874-4968) usg.com Manufactured by United States Gypsum Company 550 West Adams Street Chicago, IL 60661 J678-USA-ENG/rev. 8-16 © 2016 USG Corporation and/or its affiliates. All rights reserved. Printed in U.S.A. Testing and Classification: Meets ASTM C834 Standard Specification for Latex-Based Sealing Compounds tested in accordance with ASTM C731, ASTM C732, ASTM C734, ASTM C736, ASTM D2202, ASTM D2203 and ASTM D2377. Also tested in accordance with ASTM E84 (surface-burning characteristics), ASTM E90 (sound tests) and ASTM E1966 (fire-resistant joint systems). ASTM E814 (through-penetration firestop systems). Surface-Burning Characteristics: 0/0 (flame spread/smoke developed) Color: Off-white Solids: 73% ± 3% Weight: 13.4 lbs./gal. (1.6Kg/L in container) pH: 8.5–9.5 VOC: 15 g/L Shelf Life: One year (in original, unopened container) under good storage practices. Note: See #4 under Limitations. Coverage (approximate): 85 linear ft. of 1/4" bead/29 oz. ctdg.; 37 linear ft. of 3/8" bead/29 oz. ctdg.; 22 linear ft. of 1/2" bead/29 oz. ctdg.; 11 linear ft. of 5/8" bead/29 oz. ctdg; 392 ft. of 1/4" bead/gal.; 174 ft. of 3/8" bead/gal.; 98 ft. of 1/2" bead/gal. Packaging: 29 oz. (850 ml) cartridge; 5 gal. (18.9 L) pail. 1. INSPECTIONS Periodic inspection of all sealant applications including fire-rated barriers is recommended to make sure that any new openings, modifications of previously installed seals, or areas exhibiting physical damage have been properly sealed or repaired. 2. SOUND TESTS Sound tests are conducted under laboratory conditions per ASTM procedures. Comparable field performance depends upon careful attention to details and workmanship. USG Sheetrock® Brand Acoustical Sealant should be used to seal all assemblies used for sound control and all assembly cutouts, such as those for electrical boxes. Back-to-back penetrations of the diaphragm, flanking paths, door and borrowed-light openings should be avoided. 3. METAL DOOR AND BORROWED-LIGHT FRAMES Apply a continuous bead of USG Sheetrock® Brand Acoustical Sealant inside door frame throat just before inserting facing panel into frame. Do not terminate gypsum panel against trim return. 4. ADDITIONAL INFORMATION See publications in USG Architectural Reference Library; (SA100), Construction Selector; (SA927), Gypsum Panels and Accessories (for information on system components); (SA727), USG Fire Stop Systems; (SA926), USG Shaft Wall Systems Catalog; and usgdesignstudio.com/sealant-fire-tests.asp. SUBMITTAL APPROVALS Job Name Contractor Date PRODUCT DATA GOOD DESIGN PRACTICES CAUTION Spray or dust may cause irritation to eyes, skin, nose, throat and upper respiratory tract. Use only in a well-ventilated area, or wear a NIOSH/MSHA-approved respirator. Wear eye protection. If eye contact occurs, flush thoroughly with water for 15 minutes. If on skin: Wash with plenty of water. If swallowed and/or irritation persists, call physician. For more information call Product Safety: 800-507-8899 or see the SDS at usg.com KEEP OUT OF REACH OF CHILDREN. TRADEMARKS The trademarks USG, SHEETROCK, IT’S YOUR WORLD. BUILD IT., the USG logo, the design elements and colors, and related marks are trademarks of USG Corporation or its affiliates. INTERNATIONAL FIRESTOP COUNCIL and THE SOURCE OF FIRESTOP EXPERTISE are registered trademarks and used with expressed permission. NOTE Products described here may not be available in all geographic markets. Consult your USG Company sales office or representative for information. NOTICE We shall not be liable for incidental and consequential damages, directly or indirectly sustained, nor for any loss caused by application of these goods not in accordance with current printed instructions or for other than the intended use. Our liability is expressly limited to replacement of defective goods. Any claim shall be deemed waived unless made in writing to us within thirty (30) days from date it was or reasonably should have been discovered. SAFETY FIRST! Follow good safety and industrial hygiene practices during handling and installation of all products and systems. Take necessary precautions and wear the appropriate personal protective equipment as needed. Read Safety Data Sheets and related literature on products before specification and/or installation. MOUNTAIN VIEW COUNTRY CLUB CLUBHOUSE TI FIRE SPRINKLER REVISION 1 NARRATIVE 7/23/20 Zack McCoy FS/BIM Designer | Project Engineer Kincaid Industries, Inc. See comments below in RED 1) Provide a current water supply report (6 months) for bearings of Hydraulic calculations. Flow test was performed by CVWD on 7/14 and calculations were updated. 2) NFPA 13 Section 23.1.3 (31) essentially requires a mock-up of the required information of Section 25.5 as amended by CFC Chapter 80. Missing information: (1) Occupancy Classification (2) Installing Contractor Information (3) Required Flow and Pressure at water supply source (4) Listing of sprinklers included in area design (K, SIN, Temp, Orif, Orientation) (5) Edition of NFPA 13 for design Will provide a sample that may be used, but shall be shown on plans. Missing information was added to the hydraulic calculation card on FS100 3) New Outdoor Patio area is lower elevation than it's supply point and should be provided with an auxiliary drain. Identify on the plans. 1” drain w/ valve was added. 4) Sheet 4 of the plans identifies the proposed use of Vicflex Sprinkler Drops. Plans shall identify the location, series and style to be used. a) Hydraulic Calculations will be required for these areas as the device presents with Increased friction losses. Flexible sprinklers were removed and won’t be used. 5) Errors were observed in the hydraulic calculations for the outdoor patio. See markups on hydraulic calculations document. Calculations were updated for the new flow test and site model. PER SHEET REVISIONS SHEET FS001) • Flow test was added • New sheet for site hydraulics added SHEET FS002) • New sheet SHEET FS100) • Missing information on the calc card was added • Drain valve added to the canopy • Confirmed 3” main • Showed riser in the correct location • Calculations updated for flow test SHEET FS200) • Flexible drops detail was removed • Replaced the branch line restraint detail SHEET FS201) • No changes OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org July 30, 2020 Kincaid Industries INC 31-065 Plantation Drive Thousand Palms, CA 92276 Re: TI Fire Sprinkler Plan Review – MOUNTAIN VIEW CC CLUBHOUSE FSS2020-0086 / 80375 POMELO, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. The following inspections/tests are required to be witnessed by the Office of the Fire Marshal staff: 1) Overhead Rough: All installed/relocated piping must be visible. 2) Final inspection: All trim is in place, 5-Year certification is current. *Water-flow signal test may be performed during the Final Inspection. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 80375 POMELO PERMIT#: FSS2020-0086 DATE ISSUED: 7/30/2020 DESCRIPTION: MOUNTAIN VIEW CC CLUBHOUSE CONTRACTOR: KINCAID INDUSTRIES INC HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible dur ing the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.