Loading...
FSS2020-0110Description: S&R DEVELOPEMENT / BRES2020-0034 /FIRE SPRINKELRS Type: FIRE SPRINKLER (WEB) Subtype: RESIDENTIAL - CUSTOM Status: FINALED Applied: 8/17/2020 ECON HOMES Approved: 8/31/2020 KHET Parcel No: 774055021 Site Address: 53225 EISENHOWER DR LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 209 Lot: 11 Issued: 8/31/2020 KHET UNIT 20 Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 3/25/2021 KHET Valuation: $4,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 206 -' / 14 I� 0 I Applied to Approved Approved to Issued Issued to Finaled ADDITIONAL NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 (760)625-5908 JCFIREPROTECTION @V ERIZON.NET CONTRACTOR J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 (760)625-5908 JCFIREPROTECTION @V ERIZON.NET OWNER S&R DEVELOPMENT, LLC. 53225 EISENHOWER DR LA QUINTA CA 92253 (760)625-5908 Printed: Wednesday, February 22, 2023 4:25:44 PM 1 of 4 WSYSiEMS CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY FIRE SPRINKLER SYSTEMS - SINGLE 101-0000-42421 0 $161.00 $161.00 8/17/20 WEB6018 034476 CREDIT J C FIRE PROTECTION ECON FAMILY DETACHED FIRE SPRINKLER SYSTEMS - SINGLE 101-0000-42420 0 $242.00 $242.00 8/17/20 WEB6018 034476 CREDIT J C FIRE PROTECTION ECON FAMILY DETACHED PC Total Paid for FIRE FEES: $403.00 $403.00 RECORDS 101-0000-42416 0 $10.00 $10.00 8/17/20 WEB6018 034476 CREDIT J C FIRE PROTECTION ECON MANAGEMENT FEE Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY 502-0000-43611 0 $5.00 $5.00 8/17/20 WEB6018 034476 CREDIT J C FIRE PROTECTION ECON ENHANCEMENT FEE Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:•• PIS,,INSIPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES DATE DATE OVERHEAD HYRO KHET 10/27/2020 10/27/2020 APPROVED REMOTE VIDEO INSPECTION OVERHEAD ROUGH KHET 10/27/2020 10/27/2020 APPROVED REMOTE VIDEO PIPING INSPECTION FIRE FINAL" KHET 3/25/2021 3/25/2021 APPROVED REMOTE VIDEO INSPECTION Printed: Wednesday, February 22, 2023 4:25:44 PM 2 of 4 WsYsrEMS 1ST PERMIT TECH (1 PERMIT TECH 8/17/2020 8/18/2020 8/17/2020 COMPLETE DAY) BUCKET 1ST FIRE (2 WK) KOHL 8/17/2020 8/31/2020 8/31/2020 APPROVED SEE ATTACHMENTS HETRICK dft BOND INFORMATION Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 8/17/2020 EtrakitContractor 1ST SUBMITTAL AREA1 AREA 11 HEAD.PDF 1 CALCS DOC 8/17/2020 EtrakitContractor 1ST SUBMITTAL AREA 2CALCS AREA 2 2 HEAD.PDF 1 DOC 8/17/2020 EtrakitContractor 1ST SUBMITTAL AREA 3CALCS AREA 3 1 HEAD.PDF 1 DOC 8/17/2020 EtrakitContractor 1ST SUBMITTAL PLANS SandR LLC Residence 1 Fire Sprinklers.pdf DOC 8/17/2020 EtrakitContractor 1ST SUBMITTAL [check gpms] vk 496 1 SPRINKLER HERAD 3.Ok Flat Concealed.pdf DOC 8/17/2020 EtrakitContractor 1ST SUBMITTAL CPVC blazemaster.pdf 1 PIPE AND FITTINGS DOC 8/17/2020 EtrakitContractor 1ST SUBMITTAL vk 329 Recessed 2.8 k 1 SPRINKLER HEAD QR.pdf DOC 8/17/2020 EtrakitContractor 1ST SUBMITTAL CHECK fig28.pdf 1 VALVE DOC 8/17/2020 EtrakitContractor 1ST SUBMITTAL spears cpvc check valve 1 HANGER page.28.pdf DOC 8/17/2020 EtrakitContractor 1ST SUBMITTAL pc-cpvc-double- 1 HANGER offset.pdf DOC 8/31/2020 EtrakitContractor race rcce 53225 1 eisenhower.pdf DOC 8/31/2020 KOHL HETRICK FSS2020-0110 - FSS2020-0110 - 1 APPROVED PLANS.pdf APPROVED PLANS.pdf Printed: Wednesday, February 22, 2023 4:25:44 PM 3 of 4 WsYsrEMS Printed: Wednesday, February 22, 2023 4:25:44 PM 4 of 4 WsYsrEMS o TYPICAL HANGER DETAILS wow, SUPPORT SPACING AT SPRINKLERS SPRINKLER SPACING �,ia"�:.�E� »".w " �000•,:w TM wxx�.N ax xw.��rox.xx.wx ax�.wx. a�N xao INSTALLATION A OwE NOTES Oa "1 .- ­ —T ar ANo 0 0 CVWD SYSTEM DATA DATE OBSERVED = 08-12-2020 INLET PRESSURE = 98.7 OUTLET PRESSURE = 78.6 ADJUSTED OUTLET PRESSURE = 70.7 "72-1c 1" RISER DETAIL A I E v I r I 0 � uc I I m D � AREA1 AREA AREA .®T�,a,awE" FIRERSPRINKLERA PIPING PLANA inn-�-n e®Tiw.arxmEx oun m• c w xw�c �i eow� NFPA 13D — GENERAL FIRE SPRINKLER NOTES 111, SYIA90L DESCRIP110N waznc vuT m vnare w/ N.»nW 1.1 �xwncw �axol N. nxrv¢ 1— IN 1.1 NFPAI3D "11i -IAAEI IAll 0FN 11 BE COgiDINA1ED IAgIxD —0 mint ru, T\��r ro �R�xx�ATa��DE ms ;, TMNFPA13DS1AU AHJ USE ONLY Eby§F o ALL£ as a�a n N 0D� � �oFcew'�LL N T Ls Y rco Et m _ a SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 3 1 HEAD.SDF JOB TITLE: AREA 3 1HD (16xl6) (15 GPM) WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) M (N/A) 70.7 (N/A) 70.7 20.0 40.0 Available pressure is 30.7 psi (43%) greater than required pressure. AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 20.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 15.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) Pi 10.0 - - - - 26.7 - - - P2 12.0 - - - - 26.0 - - - P3 12.0 - - - - 26.0 - - - P4 10.0 K= 3.00 25.0 15.0 1 10.5 - - - - 26.4 - - - 2 12.5 - - - - 25.8 - - - 3 12.5 - - - - 25.8 - - - 4 10.5 - - - - 25.1 - - - A 12.5 - - - - 25.8 - - - B 10.5 - - - - 26.4 - - - B1 10.5 - - - - 26.4 - - - C 10.5 - - - - 27.2 - - - TOR 10.5 - - - - 27.7 - - - FS1 4.0 - - - - 30.8 - - - FS2 4.0 - - - - 33.8 - - - BOR 0.5 - - - - 35.7 - - - DOM 0.5 HOSE STREAM 36.5 5.0 UG -3.0 - - - - 38.7 - - - M -3.0 SOURCE 40.0 20.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 3 1 HEAD.SDF JOB TITLE: AREA 3 1HD (16xl6) (15 GPM) PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 0.0 1.101 PL 0.50 PF 0.0 P1 10.0 0.0 26.7 0.0 0.0 150 FTG E PE -0.2 1 10.5 0.0 26.4 0.0 0.000 TL 7.50 PV Pipe: 2 0.0 1.101 PL 0.50 PF 0.0 P2 12.0 0.0 26.0 0.0 0.0 150 FTG T PE -0.2 2 12.5 0.0 25.8 0.0 0.000 TL 6.50 PV Pipe: 3 0.0 1.101 PL 0.50 PF 0.0 P3 12.0 0.0 26.0 0.0 0.0 150 FTG T PE -0.2 3 12.5 0.0 25.8 0.0 0.000 TL 6.50 PV Pipe: 4 -15.0 1.101 PL 0.50 PF 0.3 P4 10.0 3.0 25.0 15.0 5.1 150 FTG E PE -0.2 4 10.5 0.0 25.1 0.0 0.040 TL 7.50 PV Pipe: 5 0.0 1.101 PL 9.75 PF 0.0 1 10.5 0.0 26.4 0.0 0.0 150 FTG 2TR PE 0.0 B 10.5 0.0 26.4 0.0 0.000 TL 23.45 PV Pipe: 6 0.0 1.101 PL 8.00 PF 0.0 2 12.5 0.0 25.8 0.0 0.0 150 FTG R PE 0.0 3 12.5 0.0 25.8 0.0 0.000 TL 9.70 PV Pipe: 7 0.0 1.101 PL 1.50 PF 0.0 3 12.5 0.0 25.8 0.0 0.0 150 FTG T PE 0.0 A 12.5 0.0 25.8 0.0 0.000 TL 7.50 PV Pipe: 8 -15.0 1.101 PL 17.00 PF 1.3 4 10.5 0.0 25.1 0.0 5.1 150 FTG ETR PE 0.0 Bl 10.5 0.0 26.4 0.0 0.040 TL 31.70 PV Pipe: 9 4.7 1.101 PL 21.25 PF 0.2 A 12.5 0.0 25.8 0.0 1.6 150 FTG 2ET2R PE 0.9 B 10.5 0.0 26.4 0.0 0.005 TL 44.65 PV Pipe: 10 4.7 1.101 PL 16.00 PF 0.1 B 10.5 0.0 26.4 0.0 1.6 150 FTG 2R PE 0.0 Bl 10.5 0.0 26.4 0.0 0.005 TL 19.40 PV Pipe: 11 -10.3 1.101 PL 29.00 PF 0.8 B1 10.5 0.0 26.4 0.0 3.5 150 FTG T3R PE 0.0 C 10.5 0.0 27.2 0.0 0.020 TL 40.10 PV Pipe: 12 -4.7 1.101 PL 66.25 PF 0.5 A 12.5 0.0 25.8 0.0 1.6 150 FTG 3E3T3R PE 0.9 C 10.5 0.0 27.2 0.0 0.005 TL 110.35 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 8/14/2020S&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 3 1 HEAD.SDF JOB TITLE: AREA 3 1HD (16x16) (15 GPM) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -15.0 1.101 PL 6.25 PF 0.5 C 10.5 0.0 27.2 0.0 5.1 150 FTG E PE 0.0 TOR 10.5 0.0 27.7 0.0 0.040 TL 13.25 PV Pipe: 14 -15.0 1.101 PL 6.50 PF 0.3 TOR 10.5 0.0 27.7 0.0 5.1 150 FTG ---- PE 2.8 FS1 4.0 0.0 30.8 0.0 0.040 TL 6.50 PV Pipe: 15 FIXED PRESSURE LOSS DEVICE FS2 4.0 0.0 33.8 0.0 3.0 psi, 15.0 gpm FS1 4.0 0.0 30.8 0.0 Pipe: 16 -15.0 1.101 PL 3.50 PF 0.5 FS2 4.0 0.0 33.8 0.0 5.1 150 FTG C PE 1.5 BOR 0.5 0.0 35.7 0.0 0.040 TL 11.50 PV Pipe: 17 -15.0 1.055 PL 2.00 PF 0.8 BOR 0.5 0.0 35.7 0.0 5.5 150 FTG 2ET PE 0.0 DOM 0.5 H.S. 36.5 5.0 0.049 TL 16.00 PV Pipe: 18 -20.0 1.055 PL 3.50 PF 0.6 DOM 0.5 H.S. 36.5 5.0 7.3 150 FTG EG PE 1.5 UG -3.0 0.0 38.7 0.0 0.084 TL 7.50 PV Pipe: 19 -20.0 1.394 PL 40.00 PF 1.4 UG -3.0 0.0 38.7 0.0 4.2 150 FTG 3E PE 0.0 M -3.0 SRCE 40.0 (N/A) 0.022 TL 64.00 PV NOTES (HASS): (1) Calculations were performed by the HASS 2020 D computer program in accordance with NFPA13 (2016) under license no. 64622225 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.006 gpm and a maximum imbalance at any node of 0.097 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 7.3 ft/sec at pipe 18. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node M under full flow conditions is SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 3 1 HEAD.SDF JOB TITLE: AREA 3 1HD (16xl6) (15 GPM) 70.70 psi with a flow of 26.28 gpm. (6) PIPE FITTINGS TABLE HASS Pipe Table Name: standard.pip PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) F E T R K C G F45 Ell Tee RunT Kplg ChkVly Gate 1.101 1.40 7.00 6.00 1.70 1.00 8.00 0.40 1.394 1.80 8.00 7.30 2.30 1.00 11.00 0.80 PAGE: M MATERIAL: CT-M HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Ell Tee 45-Ell TeeRun Kouplg ChkVly GatVly NPTee 1.055 3.00 8.00 2.00 3.00 0.00 8.00 0.00 8.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 3 1 HEAD.SDF JOB TITLE: AREA 3 1HD (16xl6) (15 GPM) WATER SUPPLY ANALYSIS Fixed Source Pressure: 70.70 psi SI 1 7010 60.0 G A U 50.0 G E p 4020 R E S 30.0 S U R 20.0 E 10.0 p s i 0.0 -14.7 LEGEND jAvailable pressure 70.70 psi @ 20.0 gpm IRequired pressure 40.05 psi @ 20.0 gpm A. Source Supply Curve B. System Demand Curve 600900 1200 1500 1800 2100 2400 2700 3000 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 8/14/2020S&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 3 1 HEAD.SDF JOB TITLE: AREA 3 1HD (16x16) (15 GPM) WATER SUPPLY CURVE 72+ I I 66+ I I I 60+ I I I 54+ I I I P 48+ R E S S 42+ U X R E 36+ ( I P S I 30+ I I I 24+ I I I 18+ I I 12+ LEGEND " I" X = Required Water Supply " 40.05 psi @ 20.0 gpm " 6+ " 0 = Available Water Supply " I" 70.70 psi @ 20.0 gpm " 0++-+---+----+-----+------+--------+--------+---------+-----------+ 8001200 1600 2000 2400 2800 3200 3600 4000 FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2 HEAD.SDF JOB TITLE: AREA 2 2HD (12xl2) (8 GPM) WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) M (N/A) 70.7 (N/A) 70.7 21.0 23.0 Available pressure is 47.7 psi (67%) greater than required pressure. AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 21.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 16.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) Pi 10.0 - - - - 9.1 - - - P2 12.0 K= 3.00 7.1 8.0 P3 12.0 K= 3.00 7.2 8.1 P4 10.0 - - - - 9.4 - - - 1 10.5 - - - - 8.9 - - - 2 12.5 - - - - 7.0 - - - 3 12.5 - - - - 7.1 - - - 4 10.5 - - - - 9.1 - - - A 12.5 - - - - 7.4 - - - B 10.5 - - - - 8.9 - - - B1 10.5 - - - - 9.1 - - - C 10.5 - - - - 9.7 - - - TOR 10.5 - - - - 10.3 - - - FS1 4.0 - - - - 13.4 - - - FS2 4.0 - - - - 16.4 - - - BOR 0.5 - - - - 18.4 - - - DOM 0.5 HOSE STREAM 19.3 5.0 UG -3.0 - - - - 21.5 - - - M -3.0 SOURCE 23.0 21.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2 HEAD.SDF JOB TITLE: AREA 2 2HD (12xl2) (8 GPM) PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 0.0 1.101 PL 0.50 PF 0.0 P1 10.0 0.0 9.1 0.0 0.0 150 FTG E PE -0.2 1 10.5 0.0 8.9 0.0 0.000 TL 7.50 PV Pipe: 2 -8.0 1.101 PL 0.50 PF 0.1 P2 12.0 3.0 7.1 8.0 2.7 150 FTG T PE -0.2 2 12.5 0.0 7.0 0.0 0.012 TL 6.50 PV Pipe: 3 -8.1 1.101 PL 0.50 PF 0.1 P3 12.0 3.0 7.2 8.1 2.7 150 FTG T PE -0.2 3 12.5 0.0 7.1 0.0 0.013 TL 6.50 PV Pipe: 4 0.0 1.101 PL 0.50 PF 0.0 P4 10.0 0.0 9.4 0.0 0.0 150 FTG E PE -0.2 4 10.5 0.0 9.1 0.0 0.000 TL 7.50 PV Pipe: 5 0.0 1.101 PL 9.75 PF 0.0 1 10.5 0.0 8.9 0.0 0.0 150 FTG 2TR PE 0.0 B 10.5 0.0 8.9 0.0 0.000 TL 23.45 PV Pipe: 6 -8.0 1.101 PL 8.00 PF 0.1 2 12.5 0.0 7.0 0.0 2.7 150 FTG R PE 0.0 3 12.5 0.0 7.1 0.0 0.012 TL 9.70 PV Pipe: 7 -16.1 1.101 PL 1.50 PF 0.3 3 12.5 0.0 7.1 0.0 5.4 150 FTG T PE 0.0 A 12.5 0.0 7.4 0.0 0.045 TL 7.50 PV Pipe: 8 0.0 1.101 PL 17.00 PF 0.0 4 10.5 0.0 9.1 0.0 0.0 150 FTG ETR PE 0.0 Bl 10.5 0.0 9.1 0.0 0.000 TL 31.70 PV Pipe: 9 -8.2 1.101 PL 21.25 PF 0.6 A 12.5 0.0 7.4 0.0 2.7 150 FTG 2ET2R PE 0.9 B 10.5 0.0 8.9 0.0 0.013 TL 44.65 PV Pipe: 10 -8.2 1.101 PL 16.00 PF 0.3 B 10.5 0.0 8.9 0.0 2.7 150 FTG 2R PE 0.0 Bl 10.5 0.0 9.1 0.0 0.013 TL 19.40 PV Pipe: 11 -8.2 1.101 PL 29.00 PF 0.5 B1 10.5 0.0 9.1 0.0 2.7 150 FTG T3R PE 0.0 C 10.5 0.0 9.7 0.0 0.013 TL 40.10 PV Pipe: 12 -7.9 1.101 PL 66.25 PF 1.3 A 12.5 0.0 7.4 0.0 2.7 150 FTG 3E3T3R PE 0.9 C 10.5 0.0 9.7 0.0 0.012 TL 110.35 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 8/14/2020S&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2 HEAD.SDF JOB TITLE: AREA 2 2HD (12xl2) (8 GPM) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -16.1 1.101 PL 6.25 PF 0.6 C 10.5 0.0 9.7 0.0 5.4 150 FTG E PE 0.0 TOR 10.5 0.0 10.3 0.0 0.045 TL 13.25 PV Pipe: 14 -16.1 1.101 PL 6.50 PF 0.3 TOR 10.5 0.0 10.3 0.0 5.4 150 FTG ---- PE 2.8 FS1 4.0 0.0 13.4 0.0 0.045 TL 6.50 PV Pipe: 15 FIXED PRESSURE LOSS DEVICE FS2 4.0 0.0 16.4 0.0 3.0 psi, 16.1 gpm FS1 4.0 0.0 13.4 0.0 Pipe: 16 -16.1 1.101 PL 3.50 PF 0.5 FS2 4.0 0.0 16.4 0.0 5.4 150 FTG C PE 1.5 BOR 0.5 0.0 18.4 0.0 0.045 TL 11.50 PV Pipe: 17 -16.1 1.055 PL 2.00 PF 0.9 BOR 0.5 0.0 18.4 0.0 5.9 150 FTG 2ET PE 0.0 DOM 0.5 H.S. 19.3 5.0 0.056 TL 16.00 PV Pipe: 18 -21.1 1.055 PL 3.50 PF 0.7 DOM 0.5 H.S. 19.3 5.0 7.7 150 FTG EG PE 1.5 UG -3.0 0.0 21.5 0.0 0.092 TL 7.50 PV Pipe: 19 -21.0 1.394 PL 40.00 PF 1.5 UG -3.0 0.0 21.5 0.0 4.4 150 FTG 3E PE 0.0 M -3.0 SRCE 23.0 (N/A) 0.024 TL 64.00 PV NOTES (HASS): (1) Calculations were performed by the HASS 2020 D computer program in accordance with NFPA13 (2016) under license no. 64622225 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.008 gpm and a maximum imbalance at any node of 0.137 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 7.7 ft/sec at pipe 18. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node M under full flow conditions is SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2 HEAD.SDF JOB TITLE: AREA 2 2HD (12xl2) (8 GPM) 70.70 psi with a flow of 40.75 gpm. (6) PIPE FITTINGS TABLE HASS Pipe Table Name: standard.pip PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) F E T R K C G F45 Ell Tee RunT Kplg ChkVly Gate 1.101 1.40 7.00 6.00 1.70 1.00 8.00 0.40 1.394 1.80 8.00 7.30 2.30 1.00 11.00 0.80 PAGE: M MATERIAL: CT-M HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Ell Tee 45-Ell TeeRun Kouplg ChkVly GatVly NPTee 1.055 3.00 8.00 2.00 3.00 0.00 8.00 0.00 8.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2 HEAD.SDF JOB TITLE: AREA 2 2HD (12xl2) (8 GPM) WATER SUPPLY ANALYSIS Fixed Source Pressure: 70.70 psi SI 1 7010 60.0 G A U 50.0 G E p 40.0 R E S 30.0 S U R 2 20.0 E -14.7 LEGEND jAvailable pressure 70.70 psi @ 21.0 gpm IRequired pressure 23.02 psi @ 21.0 gpm A. Source Supply Curve B. System Demand Curve 600900 1200 1500 1800 2100 2400 2700 3000 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 8/14/2020S&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2 HEAD.SDF JOB TITLE: AREA 2 2HD (12x12) (8 GPM) WATER SUPPLY CURVE 72+ I I 66+ I I I 60+ I I I 54+ I I I P 48+ R E S S 42+ U R E 36+ ( I P S I 30+ I I I 24+ X I I 18+ I I 12+ LEGEND " I" X = Required Water Supply " 23.02 psi @ 21.0 gpm " 6+ " 0 = Available Water Supply " I" 70.70 psi @ 21.0 gpm " 0++-+---+----+-----+------+--------+--------+---------+-----------+ 8001200 1600 2000 2400 2800 3200 3600 4000 FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1 HEAD.SDF JOB TITLE: AREA 1 1HD (16xl6) (15 GPM) WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) M (N/A) 70.7 (N/A) 70.7 20.0 39.9 Available pressure is 30.8 psi (44%) greater than required pressure. AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 20.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 15.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) Pi 10.0 K= 3.00 25.0 15.0 P2 12.0 - - - - 25.7 - - - P3 12.0 - - - - 25.7 - - - P4 10.0 - - - - 26.6 - - - 1 10.5 - - - - 25.1 - - - 2 12.5 - - - - 25.4 - - - 3 12.5 - - - - 25.4 - - - 4 10.5 - - - - 26.3 - - - A 12.5 - - - - 25.4 - - - B 10.5 - - - - 26.0 - - - B1 10.5 - - - - 26.3 - - - C 10.5 - - - - 27.0 - - - TOR 10.5 - - - - 27.6 - - - FS1 4.0 - - - - 30.6 - - - FS2 4.0 - - - - 33.6 - - - BOR 0.5 - - - - 35.6 - - - DOM 0.5 HOSE STREAM 36.4 5.0 UG -3.0 - - - - 38.5 - - - M -3.0 SOURCE 39.9 20.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1 HEAD.SDF JOB TITLE: AREA 1 1HD (16xl6) (15 GPM) PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -15.0 1.101 PL 0.50 PF 0.3 P1 10.0 3.0 25.0 15.0 5.1 150 FTG E PE -0.2 1 10.5 0.0 25.1 0.0 0.040 TL 7.50 PV Pipe: 2 0.0 1.101 PL 0.50 PF 0.0 P2 12.0 0.0 25.7 0.0 0.0 150 FTG T PE -0.2 2 12.5 0.0 25.4 0.0 0.000 TL 6.50 PV Pipe: 3 0.0 1.101 PL 0.50 PF 0.0 P3 12.0 0.0 25.7 0.0 0.0 150 FTG T PE -0.2 3 12.5 0.0 25.4 0.0 0.000 TL 6.50 PV Pipe: 4 0.0 1.101 PL 0.50 PF 0.0 P4 10.0 0.0 26.6 0.0 0.0 150 FTG E PE -0.2 4 10.5 0.0 26.3 0.0 0.000 TL 7.50 PV Pipe: 5 -15.0 1.101 PL 9.75 PF 0.9 1 10.5 0.0 25.1 0.0 5.1 150 FTG 2TR PE 0.0 B 10.5 0.0 26.0 0.0 0.040 TL 23.45 PV Pipe: 6 0.0 1.101 PL 8.00 PF 0.0 2 12.5 0.0 25.4 0.0 0.0 150 FTG R PE 0.0 3 12.5 0.0 25.4 0.0 0.000 TL 9.70 PV Pipe: 7 0.0 1.101 PL 1.50 PF 0.0 3 12.5 0.0 25.4 0.0 0.0 150 FTG T PE 0.0 A 12.5 0.0 25.4 0.0 0.000 TL 7.50 PV Pipe: 8 0.0 1.101 PL 17.00 PF 0.0 4 10.5 0.0 26.3 0.0 0.0 150 FTG ETR PE 0.0 Bl 10.5 0.0 26.3 0.0 0.000 TL 31.70 PV Pipe: 9 5.6 1.101 PL 21.25 PF 0.3 A 12.5 0.0 25.4 0.0 1.9 150 FTG 2ET2R PE 0.9 B 10.5 0.0 26.0 0.0 0.006 TL 44.65 PV Pipe: 10 -9.4 1.101 PL 16.00 PF 0.3 B 10.5 0.0 26.0 0.0 3.2 150 FTG 2R PE 0.0 Bl 10.5 0.0 26.3 0.0 0.017 TL 19.40 PV Pipe: 11 -9.4 1.101 PL 29.00 PF 0.7 B1 10.5 0.0 26.3 0.0 3.2 150 FTG T3R PE 0.0 C 10.5 0.0 27.0 0.0 0.017 TL 40.10 PV Pipe: 12 -5.6 1.101 PL 66.25 PF 0.7 A 12.5 0.0 25.4 0.0 1.9 150 FTG 3E3T3R PE 0.9 C 10.5 0.0 27.0 0.0 0.006 TL 110.35 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 8/14/2020S&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1 HEAD.SDF JOB TITLE: AREA 1 1HD (16x16) (15 GPM) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -15.0 1.101 PL 6.25 PF 0.5 C 10.5 0.0 27.0 0.0 5.1 150 FTG E PE 0.0 TOR 10.5 0.0 27.6 0.0 0.040 TL 13.25 PV Pipe: 14 -15.0 1.101 PL 6.50 PF 0.3 TOR 10.5 0.0 27.6 0.0 5.1 150 FTG ---- PE 2.8 FS1 4.0 0.0 30.6 0.0 0.040 TL 6.50 PV Pipe: 15 FIXED PRESSURE LOSS DEVICE FS2 4.0 0.0 33.6 0.0 3.0 psi, 15.0 gpm FS1 4.0 0.0 30.6 0.0 Pipe: 16 -15.0 1.101 PL 3.50 PF 0.5 FS2 4.0 0.0 33.6 0.0 5.1 150 FTG C PE 1.5 BOR 0.5 0.0 35.6 0.0 0.040 TL 11.50 PV Pipe: 17 -15.0 1.055 PL 2.00 PF 0.8 BOR 0.5 0.0 35.6 0.0 5.5 150 FTG 2ET PE 0.0 DOM 0.5 H.S. 36.4 5.0 0.049 TL 16.00 PV Pipe: 18 -20.0 1.055 PL 3.50 PF 0.6 DOM 0.5 H.S. 36.4 5.0 7.3 150 FTG EG PE 1.5 UG -3.0 0.0 38.5 0.0 0.084 TL 7.50 PV Pipe: 19 -20.0 1.394 PL 40.00 PF 1.4 UG -3.0 0.0 38.5 0.0 4.2 150 FTG 3E PE 0.0 M -3.0 SRCE 39.9 (N/A) 0.022 TL 64.00 PV NOTES (HASS): (1) Calculations were performed by the HASS 2020 D computer program in accordance with NFPA13 (2016) under license no. 64622225 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.006 gpm and a maximum imbalance at any node of 0.096 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 7.3 ft/sec at pipe 18. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node M under full flow conditions is SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1 HEAD.SDF JOB TITLE: AREA 1 1HD (16xl6) (15 GPM) 70.70 psi with a flow of 26.33 gpm. (6) PIPE FITTINGS TABLE HASS Pipe Table Name: standard.pip PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) F E T R K C G F45 Ell Tee RunT Kplg ChkVly Gate 1.101 1.40 7.00 6.00 1.70 1.00 8.00 0.40 1.394 1.80 8.00 7.30 2.30 1.00 11.00 0.80 PAGE: M MATERIAL: CT-M HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Ell Tee 45-Ell TeeRun Kouplg ChkVly GatVly NPTee 1.055 3.00 8.00 2.00 3.00 0.00 8.00 0.00 8.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1 HEAD.SDF JOB TITLE: AREA 1 1HD (16xl6) (15 GPM) WATER SUPPLY ANALYSIS Fixed Source Pressure: 70.70 psi SI 1 7010 60.0 G A U 50.0 G E p 4020 R E S 30.0 S U R 20.0 E 10.0 p s i 0.0 -14.7 LEGEND jAvailable pressure 70.70 psi @ 20.0 gpm IRequired pressure 39.92 psi @ 20.0 gpm A. Source Supply Curve B. System Demand Curve 600900 1200 1500 1800 2100 2400 2700 3000 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 8/14/2020S&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1 HEAD.SDF JOB TITLE: AREA 1 1HD (16x16) (15 GPM) WATER SUPPLY CURVE 72+ I I 66+ I I I 60+ I I I 54+ I I I P 48+ R E S S 42+ U X R E 36+ ( I P S I 30+ I I I 24+ I I I 18+ I I 12+ LEGEND " I" X = Required Water Supply " 39.92 psi @ 20.0 gpm " 6+ " 0 = Available Water Supply " I" 70.70 psi @ 20.0 gpm " 0++-+---+----+-----+------+--------+--------+---------+-----------+ 8001200 1600 2000 2400 2800 3200 3600 4000 FLOW (GPM) Page 1 of 6 ® MICROFAST° QUICK 41RESPONSE PENDENT SPRINKLER VK329 (K2.8) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK329 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Polytetrafluoroethelyne (PTFE) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global has no approval classification for PTFE and Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS c&s cULus Listed: Category VNIV FM FM Approved: Class Series 2000 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 2.8 U.S. (40.3 metric**) Glass -bulb fluid temperature rated to -65 °F (-55 °C) Viking Technical Data may be found on Overall Length: 2-1/4" (58 mm) The Viking Corporation's Web site at *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). http://www.vikinggroupinc.com. The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). The Web site may include a more recent Material Standards: I edition of this Technical Data Page. Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C26000 Bushing: Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring -Exposed, Screw -Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring -Exposed Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Upright and Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and Black PTFE = N Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G For example, sprinkler VK329 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12981AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000). B. Wrench for Recessed Pendent Sprinklers: Part No. 16036W/B** (available since 2011) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A'/z' ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Form No. F_061714 16.01.28 Rev 16.1 Replaces form F_061714 Rev. 14.2 (Revised temperature suffix designation) Page 2 of 6 ® MICROFAST° QUICK 41RESPONSE PENDENT SPRINKLER VK329 (K2.8) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Sprinkler Cabinets: A. Six -head capacity: Part No. 01724A (available since 1971) B. Twelve -head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat -sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast° Quick Response Pendent Sprinkler VK329 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler Clip Wrench Flat Protective Sprinkler Cap i "'adih P10896 • AMM Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_061714 16.01.28 Rev 16.1 Page 3 of 6 ® MICROFAST° QUICK 41RESPONSE PENDENT SPRINKLER VK329 (K2.8) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' z Ceiling Temperature Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and Black PTFE Corrosion -Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. s The corrosion -resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and PTFE coatings. Sprinkler wrench 16036W/ for recessed pendent sprinklers ** A 1/2" ratchet is require (not available from Vikini H } Carefully slide the wrench sideways around the protective cap, ensuring engagement witt the sprinkler wrench flats Figure 2: Wrench 16036W/B for Recessed Pendent Sprinklers Form No. F_061714 16.01.28 Rev 16.1 Page 4 of 6 ® MICROFAST° QUICK RESPONSE PENDENT SPRINKLER VK329 (K2.8) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 1 (UL) Temperature KEY The Viking Microfast® Quick Response W: Finis Neon (if applicable) Pendent Sprinkler VK329 Maximum 175 PSI (12 Bar) WWP Base Sprinkler p Thread Size Nominal K-Factor Overall Length Listings and Approvals' Part SIN (Refer also to Design Criteria.) Number Style NPT ESP U.S. I metricz Inches I mm cULus° I VdS I LPCB I C L 12981 VK329 Pendent 1/2" 15 mm 2.8 40.3 2-1/4 58 A1Z, 61Y -- NOTICE Office) 06718E VK329 Pendent 1/2" 15 mm 2.8 40.3 2-3/16 56 A1Z, B1Y -- Approved Escutcheons Approved Temperature Ratings Approved Finishes Y - Standard surface -mounted escutcheon or the A- 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 Viking Microfast® Model F-1 Adjustable Escutcheon, or °C), 200 °F (93 °C), 286 °F (141 °C) 1 - BrassChrome, White recessed with the Viking Micromatic° Model E-1, E-2, or B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 6 Polyester Black Polyester E3 Recessed Escutcheon °C), and 200 °F (93 °C) and Black PTFE Z - Standard surface -mounted escutcheon or the Viking Microfast® Model F-1 Adjustable Escutcheon Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. ° Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 6 cULus Listed as corrosion -resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast° Quick Response Pendent Sprinkler VK329 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT. Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_061714 16.01.28 Rev 16.1 Page 5 of 6 ® MICROFAST° QUICK 41RESPONSE PENDENT SPRINKLER VK329 (K2.8) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 (FM) Temperature KEY The Viking Microfast® Quick Response Finish Pendent Sprinkler VK329 AIXFEscutcheon (if applicahle) Maximum 175 PSI (12 Bar) WWP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' Number' SIN Style (Refer also to Design Criteria.) NPT BSP U.S. metric2 Inches mm 12981 VK329 Pendent 112" 15 mm 2.8 40.3 2-1/4 1 58 A1Z NOTICE.. Office) 16718B VK329 I Pendent 1 112" 15 mm 2.8 40.3 2-3/16 1 56 1 A1Z Approved Temperature Ratings Approved Finishes Approved Escutcheons A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 -F 1 - Brass and Chrome Z - Standard surface -mounted escutcheon or the (93 °C), 286 °F (141 °C) Viking Microfast® Model F-1 Adjustable Escutcheon Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. s This table shows the FM Approvals available at the time of printing. Other approvals may be in process. ^ Other colors are available on request with the same Approvals as the standard colors. DESIGN CRITERIA - FM AGE I (Also refer to Approval Chart 2 above.) FM Approval Reauirements: The Viking Microfast® Quick Response Pendent Sprinkler VK329 is FM Approved as quick response Non -storage upright and pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT. Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_061714 16.01.28 Rev 16.1 Page 6 of 6 ® MICROFAST° QUICK RESPONSE PENDENT N4 I KJ SPRINKLER VK329 (K2.8) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1 /2" (15 mm) NPT` t — All' 2-1/4" (57 mm) i .l �r— T 1-3/4" (44.5 mm Installed with a standard 1/8" surface -mounted escutcheon Ceiling Opening Size: 2-516/" (58.7 mm) minimum 2-1/2" (63.5 mm) maximum 2-1/8" (54 mm) I&A. 1-1/2" 2"I (38 mm) (51 mm) Min. Max. Installed with a Microfast Note: At maximum, adapter is Model F-1 Adjustable exposed 1/2" (12.7 mm) from Escutcheon face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon ANEW Ceiling Opening Size: 2-516/" (58.7 mm) minimum 2-1/2" (63.5 mm) maximum 2-1/8" 2-1/8" (54 mm) (54 mm) 1 3/4 (44.5 mm) Max. (28.6 mm) Min. 2 (28.6 mm) (51 mm) � , Min. Max. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread -on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_061714 16.01.28 Rev 16.1 Replaces form F_061714 Rev. 14.2 (Revised temperature suffix designation) Page 1 of 5 N4 I KJ® FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Viking Freedom") Residential Concealed Pendent Sprinkler VK496 is a small thermosensitive, glass -bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 3.0 (43.2 metric*), allows the sprinkler's efficient use of available water supplies for the hydraulically designed fire -protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre -assembled with a threaded adapter for installation with a low -profile small -diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push -on", "thread -off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2" (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL- US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS e&s UL Listed (C-UL-US-EU): Category VKKW Eu Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 3.0 U.S. (43.2 metric*) Glass -bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C31600 Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-051000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic Available Finishes and Temperature Ratings: Finish Brass ENT Suffix A JN Temperature 155 *F (68 *C) 200*F (93 *C) Suffix B E Ordering Information: Refer to Tables 1 and 2. WARNING: Cancer and Reproductive Harm- www. P65Warni ngs.ca.gov Form No. F_032218 19.03.21 Rev 19.1 New page. Page 2 of 5 N4 I Kj® FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat -sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pressure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK496 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: ORDERING Instructions: Using the •R• sprinkler base part number, .. the suffix the suffix for Order a cover for the desired.. the desired Temperature Rating. plate Size 1: Finishes 2: Temperature Ratings Sprinkler Description Suffix, Nominal Rating Bulb Color Max. Ambient Ceiling Suffix Base Part NPT BSPT No. Inch mm Temperature 22773 1/2 -- Brass A 155 °F (68 °C) Red 100 °F (38 °C) B ENT 3,4 JN 200 °F (93 °C) Green 150 °F (65 °C) E Example: 22773AE = 200 °F (93 °C) Temperature Rated Sprinkler with a standard Brass finish. Accessories Sprinkler Wrenches (see Figure 1): A. Heavy Duty Part Number: 14047WB5 B. Head Cabinet Wrench Part Number: 140311 Sprinkler Cabinet: Part number 01731A. Footnotes I Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. z. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. LIL Listed as corrosion resistant. 4. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. 5. Requires a 1/2" ratchet which is not available from us. 6. Optional for removal of the protective cap. Ideal for sprinkler cabinets. Form No. F_032218 19.03.21 Rev 19.1 Page 3 of 5 N4 I Kj® FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com COVERTABLE 2: ORDERING INFORMATION Instructions: Using the cover plate base part number, .. the suffix for the desired Finish .. the suffix for the required Cover Plate Nominal Rating. 1: Finishes Temperature Rating Matrix' z Cover Plate Size Cover Plate Sprinkler Sprinkler Max. Base Part Style Inch (mm) Number Description Suffixs N urinal Nominal Rating AmbienTemper Suffix (Required) tubing 13504 2-3/4 (70) Round Polished Chrome F 135 °F (57 °C) 155 °F (68 °C) 100 °F (38 °C) A 13642 3-5/16 (84) Round Brushed Chrome F-/B 165 °F (73 °C)3 200 °F (93 °C) 150 °F (65 °C) C 15394 3-5/16 (84) Square Bright Brass B Corrosion Resistant Sprinkler Coating: ENT Antique Brass B-/A Brushed Brass B-/B Brushed Copper E-/B Example: 13504MA/W = Painted White M-/W 135 °F (57 °C) Temperature Rated 2-3/4" (70 mm) Diameter Round Cover Plate with a Painted White finish. Painted Ivory MA Painted Black M-/B Footnotes 1 The sprinkler temperature rating is stamped on the deflector. s. Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. Maximum ambient temperature for cover assembly is 100 °F (38 °C). 4. Part number shown is the base part number. For complete part number, refer to current our price list schedule. 5. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. 6. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. Form No. F_032218 19.03.21 Rev 19.1 Page 4 of 5 ® FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com APPROVAL CHART VK496, 3.0 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D Sprinkler Base Thread Size Nominal K-Factor Part Number I SIN Maximum Water Working Pressure Inches mm U.S. metric z 22773 VK496 1/2 15 3.0 43.2 175 psi (12 bar) Maximum Listings and Coverage Area 5 All Temperatures Deflector A rovals3 pp Minimum Spacing W X L to Ceiling Installation Type Ft. Flow Pressure Ft. X Ft. (m) (m X m) gpm (Lpm) PSI (bar) c@us4 Eu 12 X 12 8 7.1 (3.7 X 3.7) (30.3) (0.49) Refer to Concealed with Cover See Footnotes 3, 4, and 8 8 14 X 14 12 16 (4.3 X 4.3) (45.4) (1.1) Figure 2 Plate Assembly. See Footnotes 6 & 7. (2.4 ) 16 X 16 15 25 (4.9 X 4.9) (56.8) (1.72) Footnotes I. Part number shown is the base part number. For complete part number, refer to current our price schedule. Y. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. I This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approv- als. Refer also to Design Criteria. a Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union. 5. For areas of coverage smaller than shown, use the "Flow' and "Pressure" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow" and "Pressure' used. 5. Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 7 Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 6. s. C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) Form No. F_032218 19.03.21 Rev 19.1 Page 5 of 5 N4 I Kj® FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) UL Listing Reguirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK496 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area" in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT. Always refer to Bulletin Form No. F 080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** Sprinkler Wrench Part No. 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. 2-1/4" (57 mm) diameter opening required in the ceiling. Step 2: 1 1 Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Sprinkler wrench flat Figure 1: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) Sprinkler frame arms Form No. F_032218 19.03.21 Rev 19.1 Page 6 of 5 ® FREEDOM° RESIDENTIAL 4 I Ki CONCEALED PENDENT SPRINKLER VK496 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1/2" (15 mm) NPT E CV co LO 2-9/16" (65 mm) Maximum NOTE: Upon sprinkler activation, the deflector descends to approximately 13116" (21 mm) below the sprinkler body. 2-1/16" (52 mm) Minimum Figure 2: Sprinkler Dimensions and Cover Installation All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 3: Identification of Custom Paint for Concealed Covers 2-3/4" (70 mm) or 3-5/16" (84 mm) J 3-5/16" (84 mm) Figure 4: Square Cover Assembly 15394 Form No. F_032218 19.03.21 Rev 19.1 New page. tqCtj Fire &Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 BlazeMaster ° CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description Tyco Fire & Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings are designed exclusively for use in wet pipe automatic fire sprinkler systems. They are made from a specially devel- oped thermoplastic compound com- posed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TFBP BlazeMaster CPVC products are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as com- pared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapters are available to connect CPVC pipe to metallic pip- ing. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. WARNING Tyco Fire & Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Da to Sizes 3/4" to 3" Maximum Working Pressure 175 psi Approvals UL, FM, CUL, NSF, Dade County, LPCB, MEA, and the City of Los Ange- les. (Refer to IH-1900, Rev. 0, Janu- ary 2005 "Installation Instruction & Technical Handbook" for exact list- ing/approval information.) Manufacture Source U.S.A. Material ❑ Pipe: ASTM F442, SDR 13.5 ❑ Fittings: ASTM F438 (Sch. 40) and ASTM F439 (Sch. 80), ASTM F1970 Color Orange An rapid reap insets HOME FIRE SPRINKLER SYSTEM BlazeMasteO) is a registered trademark of Noveon IP Holding Corp. Page 1 of 6 JANUARY, 2006 TFP1915 Page 2 of 6 TFP1915 WATER NOMINAL AVERAGE AVERAGE WEIGHT FILLED WEIGHT FT. OF PIPE WEIGHT PER LIFT SIZE O.D. I.D. Ibs./ft. Ibs./ft. PER LIFT Ibs. 3/4" 1.050" 0.874" 0.18 0.44 7875 1339 1" 1.315" 1.101, 0.26 0.67 5040 1320 1-1/4" 1.660" 1.394" 0.42 1.08 2835 1191 1-1/2" 1.9001, 1.598" 0.54 1.41 2205 1213 2" 2.375" 2.003" 0.84 2.20 1260 1084 2-1/2" 2.875" 2.423" 1.26 3.26 1215 1531 3" 3.500" 2.952" 1.87 4.83 720 1344 Installation Tyco Fire and Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings are to be installed in accord- ance with IH-1900, Rev. 0, January 2005 "Installation Instruction & Techni- cal Handbook". FIGURE 1 — PIPE DIMENSIONS Care and Maintenance The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or product manufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central sta- tion alarms. TFP1915 Page 3 of 6 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT SCHD. WEIGHT TYPE NUMBER (T/O) (lb.) TEE 80000 3/4" 5/8" 40 0.11 T/O 80001 1" 11/16" 40 0.19 80002 1-1/4" 7/8" 40 0.26 80003 1-1/2" 1-1/16" 80 0.51 80004 2" 1-3/8" 80 0.90 80005 2-1/2" 1-9/16" 80 1.59 T/O T/O 80006 3" 1-13/16" 80 2.41 XxYxZ X Y Z 3/4" x 3/4" x 1" 3/4" 3/4" 5/8" 80132 40 0.14 80133 1" x 3/4" x 3/4" 9/16" 9/16" 3/4" 40 0.14 80134 1" x 3/4" x 1" 3/4" 11/16" 3/4" 40 0.17 80260 1" x 1" x 3/4" 5/8" 5/8" 13/16" 40 0.16 80135 1-1/4" x 1" x 3/4" 5/8" 5/8" 15/16" 40 0.21 80136 1-1/4" x 1" x 1" 3/4" 3/4" 15/16" 40 0.22 80137 1-1/4" x 1" x 1-1/4" 15/16" 15/16" 7/8" 40 0.26 REDUCING TEE 80261 1-1/4" x 1-1/4" x 3/4" 5/8" 5/8" 7/8" 40 0.23 80262 1-1/4" x 1-1/4" x 1" 3/4" 3/4" 7/8" 40 0.26 Z 80138 1-1/4" x 1-1/4" x 1-1/2" 1" 1" 1" 80 0.43 T/O 80140 1-1/2" x 1-1/4" x 3/4" 9/16" 9/16" 1" 80 0.36 80141 1-1/2" x 1-1/4" x 1" 9/16" 9/16" 1-1/16" 80 0.38 80263 80264 1-1/2" x 1-1/2" x 3/4" 1-1/2" x 1-1/2" x 1" 9/16" 9/16" 9/16" 9/16" 1" 1-1/16" 80 80 0.36 0.38 X Y 80275 1-1/2" x 1-1/2" x 1-1/4" 7/8" 7/8" 1" 80 0.45 T/O T/O 80265 2" x 2" x 3/4" 3/4" 3/4" 1-3/8" 80 0.61 80266 2" x 2" x 1" 7/8" 7/8" 1-3/8" 80 0.66 80274 2" x 2" x 1-1/4" 1-1/16" 1-1/16" 1-3/8" 80 0.74 80267 2" x 2" x 1-1/2" 1-1/8" 1-1/8" 1-3/8" 80 0.78 80271 2-1/2" x 2-1/2" x 1" 1-9/16" 1-9/16" 1-9/16" 80 1.43 80272 2-1/2" x 2-1/2" x 1-1/4" 1-9/16" 1-9/16" 1-9/16" 80 1.46 80273 2-1/2" x 2-1/2" x 1-1/2" 1-9/16" 1-9/16" 1-9/16" 80 1.48 80276 2-1/2" x 2-1/2" x 2" 1-9/16" 1-9/16" 1-9/16" 80 1.50 80270 3" x 3" x 1-1/2" 1-13/16" 1-13/16" 1-13/16" 80 2.28 80268 3" x 3" x 2" 1-13/16" 1-13/16" 1-3/4" 80 2.25 80269 3" x 3" x 2-1/2" 1-13/16" 1-13/16" 1-13/16" 80 2.44 CROSS & REDUCING CROSS 80009 3/4" 9/16" 40 0.13 T/O 80010 1" 11/16" 40 0.23 80011 1-1/4" 15/16" 40 0.34 80012 1-1/2" 1-1/16" 80 0.67 80013 2" 1-5/16" 80 1.00 80014 2-1/2" 1-9/16" 80 1.91 T/O 80008 3" 1-13/16" 80 2.89 80015 1" x 1" x 3/4" x 3/4" 7/8" 40 0.28 T/O T/0 80025 3/4" 5/8" 40 0.09 90' ELBOW & REDUCING ELBOW 80026 1" 3/4" 40 0.14 80027 1-1/4" 7/8" 40 0.21 X 80028 1-1/2" 1-1/16" 80 0.40 T/O 80029 2" 1-5/16" 80 0.79 80030 2-1/2" 1-9/16" 80 1.14 Y 80031 3" 1-13/16" 80 1.82 XxY X Y T/O E80032 1" x 3/4" 11116" 13/16" 40 0.16 FIGURE 2 - FITTING DIMENSIONS (Part 1 of 4) Page 4 of 6 TFP1915 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT SCHD. WEIGHT TYPE NUMBER (T/O) (lb.) 45" ELBOW 80050 3/4" 3/8" 40 0.08 T/O 80051 1" 3/8" 40 0.11 80052 1-1/4" 3/4" 40 0.20 80053 1-1/2" 1/2' 80 0.31 T/O,!!!� 80054 2" 3/4" 80 0.56 80055 2-1/2" 13/16" 80 0.89 80056 3" 1" 80 1.19 80075 3/4" 1/8" 40 0.07 COUPLING & 80076 1" 1/8" 40 0.11 REDUCING COUPLING 80077 1-1/4" 3/16" 40 0.12 80078 1-1/2" 3/16' 80 0.25 80079 2" 3/16" 80 0.38 80080 2-1/2" 1/4" 80 0.67 T/O 80081 3" 3/16" 80 0.91 80220 1" x 3/4" 1/8" 40 0.08 80200 1" x 3/4" 7/16" 40 0.04 80201 1-1/4" x 3/4" 1/2" 40 0.11 80202 1-1/4" x 1" 5/16" 40 0.12 80203 1-1/2" x 3/4" 5/8" 80 0.16 80204 1-1/2" x 1" 1/2" 80 0.14 REDUCER BUSHING 80205 1-1/2" x 1-1/4" 3/8" 80 0.17 80206 2" x 3/4" 13/16" 80 0.27 80207 2" x 1" 11/16' 80 0.26 80208 2" x 1-1/4" 9/16" 80 0.24 80209 2"x1-1/2" 7/16" 80 0.19 T/O 80215 2-1/2" x 1" 15/16" 80 0.42 80214 2-1/2" x 1-1/4" 13/16" 80 0.45 80213 2-1/2" x 1-1/2" 11/16" 80 0.46 80211 2-1/2" x 2" 5/8" 80 0.29 80210 3" x 2" 3/4" 80 0.72 80212 3" x 2-1/2" 1/2" 80 0.47 CAP 80100 3/4" 5/16" 40 0.04 80101 1" 3/8" 40 0.06 80102 1-1/4" 7/16" 40 0.10 80103 1-1/2" 11/16" 80 0.20 80104 2" 5/8" 80 0.31 T/O 80105 2-1/2" 7/8" 80 0.58 80106 3" 1" 80 0.88 GROOVED T/O PIPE O.D. COUPLING ADAPTER 2-5/16" 1-1/4" (1.660") 80160 1-1/4" x 1-1/4" Groove 40 0.78 80161 1-1/2" x 1-1/2" Groove 2-5/16" 1-1/2" (1.900") 80 0.95 PIPE 80162 2" x 2" Groove 2-5/16" 2" (2.375") 80 1.42 O.D. 80163 2-1/2" x 2-1/2" Groove 2-5/16" 2-1/2" (2.875") 80 2.28 80164 3" x 3" Groove 2-1/4" 3" (3.500") 80 3.00 T/O -I 80169 2-1/2" x 76,1 mm Groove 2-5/16" 76,1 mm (3.000") 80 2.28 FIGURE 2 - FITTING DIMENSIONS (Part 2 of 4) TFP1915 Page 5 of 6 FITTING PART NOMINAL TAKE-OUT WEIGHT TYPE NUMBER NOMINAL SIZE (TKO) SCHD. (lb.) SPRINKLER HEAD ADAPTER 80175E 3/4" x 112" NPT 7/16" 80 0.20 80176E 1" x 1/2" NPT 7/16" 80 0.22 ;_T/0 80175WL 3/4" x 1/2" NPT 7/16" 40 0.16 80179 1" x 3/4" NPT 13/16" 40 0.43 SPRINKLER HEAD ADAPTER 80175W 3/4" x 112" NPT 1/2" 40 0.19 T/O 80176W 1" x 1/2" NPT 1/2" 40 0.18 SPRINKLER HEAD ADAPTER (SPIGOT) 80177L 3/4" x 1/2" NPT 1/2" 40 0.16 80178 1" x 1/2" NPT 9/16" 40 0.20 80180 1"x 3/4" NPT 7/8" 40 0.40 T/O FEMALE ADAPTER 80142 3/4" x 3/4" NPT 13/16" 40 0.41 80145 1' x 1" NPT 7/8" 40 0.63 80146 1-1/4" x 1-1/4" NPT 1-1/8" 40 1.03 80147 1-1/2" x 1-1/2" NPT 1-3/8" 80 1.42 80148 2" x 2" NPT 1-11/16" 80 2.66 —T/O MALE ADAPTER 80157 3/4" x 3/4" NPT 1-5/16" 40 0.33 80158 1' x 1" NPT 1-3/8" 40 0.56 —T/O — XxYxZ X Y Z SPRINKLER HEAD ADAPTER TEE 80250 3/4" x 3/4" x 1/2" NPT 9/16" 9/16" 1" 40 0.22 Z 80251 1" x 1" x 1/2" NPT 11/16" 11/16" 1-3/16" 40 0.29 T/O 80249 1" x 1" x 1" NPT 15/16" 15/16" 1-9/16" 40 0.73 80256 1-1/4" x 1" x 1/2" NPT 7/16" 9/16" 1-5/16" 40 0.30 80252 1-1/4" x 1-1/4" x 1/2" NPT 7/16" 7/16" 1-5/16" 40 0.31 80257 1-1/2" x 1-1/4" x 1/2" NPT 1/2" 11/16" 1-7/16" 80 0.43 X Y l �=T/10 80254 1-1/2" x 1-1/2" x 1/2" NPT 1/2" 1/2" 1-7/16" 80 0.46 T/O 80258 2" x 1-1/2" x 1/2" NPT 1/2" 5/8" 1-11/16" 80 0.56 80253 2" x 2" x 1/2" NPT 1/2" 1/2" 1-11/16" 80 0.62 FIGURE 2 — FITTING DIMENSIONS (Part 3 of 4) Page 6 of 6 TFP1915 FITTING TYPE PART NUMBER NOMINAL SIZE NOMINAL TAKE-OUT (T/O) SCHD. WEIGHT (Ib.) BACK-TO-BACK TEE X x Y x Z X Y, Z X T/O 4j Y 1 80459 1" x 1/2" NPT x 1/2" NPT 5/8" 1-5/16" 40 0.48 80460 1" x 1/2" NPT x 1/2" NPT 5/8" 1-3/16" 40 0.46 Z T/O T/O BACK-TO-BACK CROSS X X Y X Z X W X, Y Z, W X T/O i iZ 80462 1" x 1" x 1/2" NPT x 1/2" NPT 5/8" 1-3/16" 40 0.46 w} I 80463 1" x 1" x 1/2" NPT x 1/2" NPT 5/8" 1-5/16" 40 0.47 T/O Y T/O T/O SPRINKLER HEAD X x Y X Y ADAPTER 90° ELBOW Y T/O 80199 3/4" x 1/2" NPT 9/16" 1" 40 0.20 80198 1" x 1/2" NPT 3/4" 1-1/4" 40 0.26 X I 80196 1" x 3/4" NPT 1-1/16" 1-7/16" 40 0.26 — T/O FIGURE 2 — FITTING DIMENSIONS (Part 4 of 4) Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantabilitv and fitness for a Dar - This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Pipe Clamps v '6. m n iv 3 N� TOLCOT" Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe Size Range: Available in 3/4" (20mm) and 1" (25mm) pipe sizes Material: Pre -Galvanized Steel Function: Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 11/2" (20mm) x 11/2" (20mm) from mounting surface. This design will ease installation by eliminating the need for wood block extension and allow retro-fit attachment of hanger to sprinkler pipe. Features: • Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not required to be bent for listed installation. • Offset edge eliminates abrasion. • Attaches easily to wood structure with two special #10 x 1 " hex head self -threading screws furnished with product. • Can be used as a single offset hanger by aligning "dimples" with top of mounting surface and utilizing two fasteners in two of the three holes provided. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish: Pre -Galvanized Order By: Part number and pipe size. Patent Pending Pipe Size Approx. Wt./100 Part No. in. (mm) lbs. (kg) 29-3/4 3/4" (20) 17.0 (7.7) 29-1 1" (25) 18.6 (8.4) Double Offset to Single Offset (38.1mm) �O O CC. 0 7 on o C (38.1mm) I:@" LISTED ll (38.1mm) I---------- , 1.5" (38.1mm) Install using a rechargeable electric drill fitted with a 5/16" (7.9mm) socket attachment with the special hex head self -tapping screws provided. Install screws until they bottom out. Pipe can be "snapped" into hanger before or after installation of the screws to the mounting surface. "Thumb tab" may be bent up to provide additional protection to the pipe, but is not required for performance of the hanger / restrainer function. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 103 B-Line series Pipe Hangers & Supports 0 9111111 om Fig. 28 - "Stand -Off" Hanger & Restrainer for CPVC Plastic Pipe Size Range — 3/4" through 2" Material — Carbon Steel, Pre -Galvanized Function — Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off" design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces. • Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation. • The "Stand-Off'I design eliminates the need for wood block extension. • Can be installed on horizontal or vertical piping regardless of mounting surface orientation. • Attaches easily to wood structure with two hex head self -threading screws furnished with product. • Installs easily using rechargeable electrical driver with 5/16" extension socket eliminating impact tool damage to pipe. • Attaches easily to steel, minimum 18 gauge with (2) 1/4" x 1'I tek type self drilling tapping screws. • UL Listed as a hanger and a restrainer for fire sprinkler piping. Approvals — Underwriters' Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1 " tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satis- fies the UL vertical restraint requirement where needed. UL Listed as a hanger and ver- tical restraint when installed on 3/8" composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper installed screw when used as a hanger only. Order by — Figure number and pipe size. Pat. # 7,455,268, Pat. # 7,832,248 FI G.27B (1) REQUIRED HIGH SIDE OFHANGER (2) HANGER APPLICATION HANGER R RESTRAINT APPLICATION FIG.2B FIG.28 FIG. FIG.28 FG� C &US LISTED Dimensions • Weights Pipe Approx. Size A B C Wt. 3/4 31/32 2 31/2 .180 1 35/16 23/1 6 31/2 .210 11/4 35/8 23/8 31/2 .225 11/2 4 21/2 31/2 .310 2 41/2 211/16 35/8 .340 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 m CUSTOMER SERVICE • 800.786.5266 www.tolco.com IC Residential Connection Char a Estimate t�ec August 12, 2020 Customer Name: Raul Padron Phone No. (760) 409-7376 Parcel No. 774-055-021 Geo. 06-06-12-4 Address: 53225 Eisenhower Dr., La Quinta LID: 687050 Block No. Lot No. 11 Size of Lot: 4,792 sq. ft. Tract No. Type of Service: R-1: Duplex: El Triplex: ❑ Apts: ❑ SWSC: $ 1,343.98 Acres: 0.11 SWSC: $12,218.00 /acre WSBFC: $ 3,707.00 SCC: $ 4,851.00 Treatment: $2,436/edu Collection: $2,415/edu Meter: $ - Meter Size: 3/4 inch Meter surcharge: $ - Service Size: 1 inch Service: $ - Meter & Service: $ 3,600.00 Backflow: $ - Other: $ - Sewer Lateral: $ - Total: $ 13,501.98 Santa Carmelita, part of Capital Improvement program, service is there but requires to be paid for. Per dwg 16575 a 1" Service extists & per dwg 15175 a sewer lateral exists. PZ 20-11288 Technician:Sara Lopez Fees Approved by: Date: . �a Information Supplied By Customer CVWD System Data Domestic Water Demand* Service Connection** Max. Flow= 5 gprn Max. Flow*= 21 Rpm Min. Pressure= 20 psi Inlet Pressure 1= 98.70 psi Fire Sprinkler Demand* Outlet Pressure= 78.60 psi Max. Flow= 21 gprn Min. Pressure= 23.1 psi Meter Size = 3/4 inch System Type: 711 Service Size= 1 inch Multi Stand Alone 1 Prior to Pressure Regulating Valve ** For Calculation Purposes- Service Connection Includes: * CVWD USES WORST CASE CONDITION ---� service Connection Pipe=C, Meter Stop, Meter, Check Valve & Shut Off Valve Calculations: O O! q�� 3/4 " METER 1 " SERVICE O Pz= Middle La Quinta �� �.P Q� 2 = 98.70 > 60 psi HGL= 350 t? meter= 7.84 RES.#= 6631 1 Lu n valves etc.= 12.26 Cr No. C 72298 RES./HT= 32 is *P = 78.60 > 23.1 psi ax.flow 21.00 GPM PROP. ELEV.= 138 tnJgT C1V1L �\Q Ps is oK 'L� OF CALNV OK to provide service TRY: Fire Sprinkler Demand Appoved by: — Date: $ /3 16 The meter sizing is for plan check purposes only. The ultimate responsibility resides with the En er-of-Record for the project. CAL FIRE - RIVERSIDE UNIT RIVERSIDE COUNTY FIRE DEPARTMENT OFFICE OF THE FIRE MARSHAL — LA QUINTA CALIFORNIA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org August 31, 2020 JC FIRE PROTECTION 81705 De Oro Avenue Indio, CA 92201 Re: Residential Fire Sprinkler Plan Review — S&R DEVELOPMENT FSS2020-0110 / 53225 EISENHOWER DRIVE, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist It it RIVERSIDE COUNTY FIRE PROTECTION PLANNING 0 RECORD OF INSPECTIONS / PERMIT CARD CVGICt/ THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. - cALLroRMA - INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 53225 EISENHOWER DR PERMIT#: FSS2020-0110 DATE ISSUED: 8/31/2020 DESCRIPTION: S&R DEVELOPMENT — RES SPK CONTRACTOR: JC FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre -pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final EF Deluge/pre-action SPRINKLER U.G. Final EF Thrust block pre -pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final EF Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final EF Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors' test Hood/duct extinguishing High pile storage High pile rack storage In -rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final EF Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final EF FIRE ALARM KNOX SYSTEM Rough -wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final EF Final for occupancy 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspectionr-. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE -INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131