FSS2020-0110Description: S&R DEVELOPEMENT / BRES2020-0034 /FIRE SPRINKELRS
Type: FIRE SPRINKLER (WEB)
Subtype: RESIDENTIAL - CUSTOM Status: FINALED
Applied: 8/17/2020 ECON
HOMES
Approved: 8/31/2020 KHET
Parcel No: 774055021 Site Address: 53225 EISENHOWER DR LA QUINTA,CA 92253
Subdivision: SANTA CARMELITA
VALE LA QUINTA Block: 209 Lot: 11
Issued: 8/31/2020 KHET
UNIT 20
Lot Sq Ft: 0
Building Sq Ft: 0 Zoning:
Finaled: 3/25/2021 KHET
Valuation: $4,000.00
Occupancy Type: Construction Type:
Expired:
No. Buildings: 0
No. Stories: 0 No. Unites: 0
Details:
206 -' / 14
I� 0
I Applied to Approved
Approved to Issued
Issued to Finaled
ADDITIONAL
NAME TYPE
NAME
ADDRESSI
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
J C FIRE PROTECTION
81705 DE ORO AVENUE
INDIO
CA
92201
(760)625-5908
JCFIREPROTECTION @V
ERIZON.NET
CONTRACTOR
J C FIRE PROTECTION
81705 DE ORO AVENUE
INDIO
CA
92201
(760)625-5908
JCFIREPROTECTION @V
ERIZON.NET
OWNER
S&R DEVELOPMENT, LLC.
53225 EISENHOWER DR
LA QUINTA
CA
92253
(760)625-5908
Printed: Wednesday, February 22, 2023 4:25:44 PM 1 of 4
WSYSiEMS
CLTD
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID
BY
FIRE SPRINKLER
SYSTEMS - SINGLE
101-0000-42421
0
$161.00
$161.00
8/17/20
WEB6018
034476
CREDIT
J C FIRE PROTECTION
ECON
FAMILY DETACHED
FIRE SPRINKLER
SYSTEMS - SINGLE
101-0000-42420
0
$242.00
$242.00
8/17/20
WEB6018
034476
CREDIT
J C FIRE PROTECTION
ECON
FAMILY DETACHED PC
Total Paid for FIRE FEES:
$403.00
$403.00
RECORDS
101-0000-42416
0
$10.00
$10.00
8/17/20
WEB6018
034476
CREDIT
J C FIRE PROTECTION
ECON
MANAGEMENT FEE
Total Paid for RECORDS MANAGEMENT FEE:
$10.00
$10.00
TECHNOLOGY
502-0000-43611
0
$5.00
$5.00
8/17/20
WEB6018
034476
CREDIT
J C FIRE PROTECTION
ECON
ENHANCEMENT FEE
Total Paid for TECHNOLOGY ENHANCEMENT FEE:
$5.00
$5.00
TOTALS:••
PIS,,INSIPECTIONS
SEQID INSPECTION TYPE INSPECTOR
SCHEDULED
COMPLETED
RESULT
REMARKS
NOTES
DATE
DATE
OVERHEAD HYRO
KHET
10/27/2020
10/27/2020
APPROVED
REMOTE VIDEO
INSPECTION
OVERHEAD ROUGH
KHET
10/27/2020
10/27/2020
APPROVED
REMOTE VIDEO
PIPING
INSPECTION
FIRE FINAL"
KHET
3/25/2021
3/25/2021
APPROVED
REMOTE VIDEO
INSPECTION
Printed: Wednesday, February 22, 2023 4:25:44 PM 2 of 4
WsYsrEMS
1ST PERMIT TECH (1
PERMIT TECH
8/17/2020
8/18/2020
8/17/2020
COMPLETE
DAY)
BUCKET
1ST FIRE (2 WK)
KOHL
8/17/2020
8/31/2020
8/31/2020
APPROVED
SEE ATTACHMENTS
HETRICK
dft
BOND INFORMATION
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
8/17/2020
EtrakitContractor
1ST SUBMITTAL AREA1
AREA 11 HEAD.PDF
1
CALCS
DOC
8/17/2020
EtrakitContractor
1ST SUBMITTAL AREA 2CALCS
AREA 2 2 HEAD.PDF
1
DOC
8/17/2020
EtrakitContractor
1ST SUBMITTAL AREA 3CALCS
AREA 3 1 HEAD.PDF
1
DOC
8/17/2020
EtrakitContractor
1ST SUBMITTAL PLANS
SandR LLC Residence
1
Fire Sprinklers.pdf
DOC
8/17/2020
EtrakitContractor
1ST SUBMITTAL
[check gpms] vk 496
1
SPRINKLER HERAD
3.Ok Flat Concealed.pdf
DOC
8/17/2020
EtrakitContractor
1ST SUBMITTAL CPVC
blazemaster.pdf
1
PIPE AND FITTINGS
DOC
8/17/2020
EtrakitContractor
1ST SUBMITTAL
vk 329 Recessed 2.8 k
1
SPRINKLER HEAD
QR.pdf
DOC
8/17/2020
EtrakitContractor
1ST SUBMITTAL CHECK
fig28.pdf
1
VALVE
DOC
8/17/2020
EtrakitContractor
1ST SUBMITTAL
spears cpvc check valve
1
HANGER
page.28.pdf
DOC
8/17/2020
EtrakitContractor
1ST SUBMITTAL
pc-cpvc-double-
1
HANGER
offset.pdf
DOC
8/31/2020
EtrakitContractor
race
rcce 53225
1
eisenhower.pdf
DOC
8/31/2020
KOHL HETRICK
FSS2020-0110 -
FSS2020-0110 -
1
APPROVED PLANS.pdf
APPROVED PLANS.pdf
Printed: Wednesday, February 22, 2023 4:25:44 PM 3 of 4
WsYsrEMS
Printed: Wednesday, February 22, 2023 4:25:44 PM 4 of 4
WsYsrEMS
o TYPICAL HANGER DETAILS wow,
SUPPORT SPACING AT SPRINKLERS
SPRINKLER SPACING
�,ia"�:.�E� »".w " �000•,:w TM wxx�.N ax
xw.��rox.xx.wx ax�.wx. a�N
xao INSTALLATION
A OwE NOTES
Oa "1 .- —T ar ANo
0
0
CVWD SYSTEM DATA
DATE OBSERVED = 08-12-2020
INLET PRESSURE = 98.7
OUTLET PRESSURE = 78.6
ADJUSTED OUTLET PRESSURE = 70.7
"72-1c
1" RISER DETAIL
A
I E v I
r
I 0
� uc
I
I
m
D �
AREA1 AREA AREA
.®T�,a,awE" FIRERSPRINKLERA PIPING PLANA inn-�-n
e®Tiw.arxmEx oun m• c w xw�c �i eow� NFPA 13D —
GENERAL FIRE SPRINKLER NOTES
111,
SYIA90L DESCRIP110N
waznc vuT m vnare w/
N.»nW 1.1 �xwncw �axol
N. nxrv¢ 1— IN 1.1
NFPAI3D
"11i -IAAEI IAll 0FN 11 BE COgiDINA1ED IAgIxD
—0 mint ru,
T\��r ro �R�xx�ATa��DE ms
;, TMNFPA13DS1AU
AHJ USE ONLY
Eby§F o
ALL£ as a�a n N
0D� � �oFcew'�LL N
T
Ls
Y rco Et
m _ a
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1
DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 3 1 HEAD.SDF
JOB TITLE: AREA 3 1HD (16xl6) (15 GPM)
WATER SUPPLY DATA
SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D
NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS.
TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI)
M (N/A) 70.7 (N/A) 70.7 20.0 40.0
Available pressure is 30.7 psi (43%) greater than required pressure.
AGGREGATE FLOW ANALYSIS:
TOTAL
FLOW AT SOURCE
20.0
GPM
TOTAL
HOSE STREAM ALLOWANCE AT SOURCE
0.0
GPM
OTHER
HOSE STREAM ALLOWANCES
5.0
GPM
TOTAL
DISCHARGE FROM
ACTIVE SPRINKLERS
15.0
GPM
NODE
ANALYSIS DATA
NODE
TAG ELEVATION
NODE TYPE
PRESSURE
DISCHARGE
(FT)
(PSI)
(GPM)
Pi
10.0
- - - -
26.7
- - -
P2
12.0
- - - -
26.0
- - -
P3
12.0
- - - -
26.0
- - -
P4
10.0
K= 3.00
25.0
15.0
1
10.5
- - - -
26.4
- - -
2
12.5
- - - -
25.8
- - -
3
12.5
- - - -
25.8
- - -
4
10.5
- - - -
25.1
- - -
A
12.5
- - - -
25.8
- - -
B
10.5
- - - -
26.4
- - -
B1
10.5
- - - -
26.4
- - -
C
10.5
- - - -
27.2
- - -
TOR
10.5
- - - -
27.7
- - -
FS1
4.0
- - - -
30.8
- - -
FS2
4.0
- - - -
33.8
- - -
BOR
0.5
- - - -
35.7
- - -
DOM
0.5
HOSE STREAM
36.5
5.0
UG
-3.0
- - - -
38.7
- - -
M
-3.0
SOURCE
40.0
20.0
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2
DATE: 8/14/20205&R LLC
RESIDENCE -
LA QUINTA
- CA
- JCP\AREA
3 1
HEAD.SDF
JOB
TITLE:
AREA
3 1HD
(16xl6)
(15 GPM)
PIPE
DATA
PIPE
TAG
Q(GPM)
DIA(IN) LENGTH
PRESS.
END
ELEV.
NOZ.
PT
DISC.
VEL(FPS)
HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI)
(GPM)
FL/FT
(PSI)
Pipe:
1
0.0
1.101
PL
0.50
PF
0.0
P1
10.0
0.0
26.7
0.0
0.0
150
FTG
E
PE
-0.2
1
10.5
0.0
26.4
0.0
0.000
TL
7.50
PV
Pipe:
2
0.0
1.101
PL
0.50
PF
0.0
P2
12.0
0.0
26.0
0.0
0.0
150
FTG
T
PE
-0.2
2
12.5
0.0
25.8
0.0
0.000
TL
6.50
PV
Pipe:
3
0.0
1.101
PL
0.50
PF
0.0
P3
12.0
0.0
26.0
0.0
0.0
150
FTG
T
PE
-0.2
3
12.5
0.0
25.8
0.0
0.000
TL
6.50
PV
Pipe:
4
-15.0
1.101
PL
0.50
PF
0.3
P4
10.0
3.0
25.0
15.0
5.1
150
FTG
E
PE
-0.2
4
10.5
0.0
25.1
0.0
0.040
TL
7.50
PV
Pipe:
5
0.0
1.101
PL
9.75
PF
0.0
1
10.5
0.0
26.4
0.0
0.0
150
FTG
2TR
PE
0.0
B
10.5
0.0
26.4
0.0
0.000
TL
23.45
PV
Pipe:
6
0.0
1.101
PL
8.00
PF
0.0
2
12.5
0.0
25.8
0.0
0.0
150
FTG
R
PE
0.0
3
12.5
0.0
25.8
0.0
0.000
TL
9.70
PV
Pipe:
7
0.0
1.101
PL
1.50
PF
0.0
3
12.5
0.0
25.8
0.0
0.0
150
FTG
T
PE
0.0
A
12.5
0.0
25.8
0.0
0.000
TL
7.50
PV
Pipe:
8
-15.0
1.101
PL
17.00
PF
1.3
4
10.5
0.0
25.1
0.0
5.1
150
FTG
ETR
PE
0.0
Bl
10.5
0.0
26.4
0.0
0.040
TL
31.70
PV
Pipe:
9
4.7
1.101
PL
21.25
PF
0.2
A
12.5
0.0
25.8
0.0
1.6
150
FTG
2ET2R
PE
0.9
B
10.5
0.0
26.4
0.0
0.005
TL
44.65
PV
Pipe:
10
4.7
1.101
PL
16.00
PF
0.1
B
10.5
0.0
26.4
0.0
1.6
150
FTG
2R
PE
0.0
Bl
10.5
0.0
26.4
0.0
0.005
TL
19.40
PV
Pipe:
11
-10.3
1.101
PL
29.00
PF
0.8
B1
10.5
0.0
26.4
0.0
3.5
150
FTG
T3R
PE
0.0
C
10.5
0.0
27.2
0.0
0.020
TL
40.10
PV
Pipe:
12
-4.7
1.101
PL
66.25
PF
0.5
A
12.5
0.0
25.8
0.0
1.6
150
FTG
3E3T3R
PE
0.9
C
10.5
0.0
27.2
0.0
0.005
TL
110.35
PV
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3
DATE: 8/14/2020S&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 3 1 HEAD.SDF
JOB TITLE: AREA 3 1HD (16x16) (15 GPM)
PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS.
END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM.
NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 13 -15.0 1.101 PL 6.25 PF 0.5
C 10.5 0.0 27.2 0.0 5.1 150 FTG E PE 0.0
TOR 10.5 0.0 27.7 0.0 0.040 TL 13.25 PV
Pipe: 14 -15.0 1.101 PL 6.50 PF 0.3
TOR 10.5 0.0 27.7 0.0 5.1 150 FTG ---- PE 2.8
FS1 4.0 0.0 30.8 0.0 0.040 TL 6.50 PV
Pipe: 15 FIXED PRESSURE LOSS DEVICE
FS2 4.0 0.0 33.8 0.0 3.0 psi, 15.0 gpm
FS1 4.0 0.0 30.8 0.0
Pipe: 16 -15.0 1.101 PL 3.50 PF 0.5
FS2 4.0 0.0 33.8 0.0 5.1 150 FTG C PE 1.5
BOR 0.5 0.0 35.7 0.0 0.040 TL 11.50 PV
Pipe: 17 -15.0 1.055 PL 2.00 PF 0.8
BOR 0.5 0.0 35.7 0.0 5.5 150 FTG 2ET PE 0.0
DOM 0.5 H.S. 36.5 5.0 0.049 TL 16.00 PV
Pipe: 18 -20.0 1.055 PL 3.50 PF 0.6
DOM 0.5 H.S. 36.5 5.0 7.3 150 FTG EG PE 1.5
UG -3.0 0.0 38.7 0.0 0.084 TL 7.50 PV
Pipe: 19 -20.0 1.394 PL 40.00 PF 1.4
UG -3.0 0.0 38.7 0.0 4.2 150 FTG 3E PE 0.0
M -3.0 SRCE 40.0 (N/A) 0.022 TL 64.00 PV
NOTES (HASS):
(1) Calculations were performed by the HASS 2020 D computer program
in accordance with NFPA13 (2016)
under license no. 64622225 granted by
HRS Systems, Inc.
208 Southside Square
Petersburg, TN 37144
(931) 659-9760
(2) The system has been calculated to provide an average
imbalance at each node of 0.006 gpm and a maximum
imbalance at any node of 0.097 gpm.
(3) Total pressure at each node is used in balancing the system.
Maximum water velocity is 7.3 ft/sec at pipe 18.
(4) Items listed in bold print on the cover sheet
are automatically transferred from the calculation report.
(5) Available pressure at source node M under full flow conditions is
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4
DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 3 1 HEAD.SDF
JOB TITLE: AREA 3 1HD (16xl6) (15 GPM)
70.70 psi with a flow of 26.28 gpm.
(6) PIPE FITTINGS TABLE
HASS Pipe Table Name: standard.pip
PAGE: F
MATERIAL: CPVC
HWC: 150
Diameter
Equivalent Fitting Lengths
in Feet
(in)
F
E
T R K
C
G
F45
Ell
Tee RunT Kplg
ChkVly
Gate
1.101
1.40
7.00
6.00 1.70 1.00
8.00
0.40
1.394
1.80
8.00
7.30 2.30 1.00
11.00
0.80
PAGE: M
MATERIAL: CT-M
HWC: 150
Diameter
Equivalent Fitting Lengths
in Feet
(in)
E
T
F R K
C
G N
Ell
Tee 45-Ell
TeeRun Kouplg
ChkVly
GatVly NPTee
1.055
3.00
8.00
2.00 3.00 0.00
8.00
0.00 8.00
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5
DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 3 1 HEAD.SDF
JOB TITLE: AREA 3 1HD (16xl6) (15 GPM)
WATER SUPPLY ANALYSIS
Fixed Source Pressure: 70.70 psi
SI 1
7010
60.0
G
A
U
50.0
G
E
p 4020
R
E
S 30.0
S
U
R 20.0
E
10.0
p
s
i
0.0
-14.7
LEGEND
jAvailable pressure
70.70 psi @ 20.0 gpm
IRequired pressure
40.05 psi @ 20.0 gpm
A. Source Supply Curve
B. System Demand Curve
600900 1200 1500 1800 2100 2400 2700 3000
FLOW (GPM)
Note: (1) Dashed Lines indicate extrapolated values from Test Results
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6
DATE: 8/14/2020S&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 3 1 HEAD.SDF
JOB TITLE: AREA 3 1HD (16x16) (15 GPM)
WATER SUPPLY CURVE
72+
I
I
66+
I
I
I
60+
I
I
I
54+
I
I
I
P 48+
R
E
S
S 42+
U X
R
E
36+
( I
P
S
I 30+
I
I
I
24+
I
I
I
18+
I
I
12+
LEGEND
"
I"
X = Required Water Supply
"
40.05 psi @ 20.0 gpm
"
6+
"
0 = Available Water Supply
"
I"
70.70 psi @ 20.0 gpm
"
0++-+---+----+-----+------+--------+--------+---------+-----------+
8001200 1600 2000 2400
2800 3200 3600 4000
FLOW (GPM)
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1
DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2 HEAD.SDF
JOB TITLE: AREA 2 2HD (12xl2) (8 GPM)
WATER SUPPLY DATA
SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D
NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS.
TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI)
M (N/A) 70.7 (N/A) 70.7 21.0 23.0
Available pressure is 47.7 psi (67%) greater than required pressure.
AGGREGATE FLOW ANALYSIS:
TOTAL
FLOW AT SOURCE
21.0
GPM
TOTAL
HOSE STREAM ALLOWANCE AT SOURCE
0.0
GPM
OTHER
HOSE STREAM ALLOWANCES
5.0
GPM
TOTAL
DISCHARGE FROM
ACTIVE SPRINKLERS
16.0
GPM
NODE
ANALYSIS DATA
NODE
TAG ELEVATION
NODE TYPE
PRESSURE
DISCHARGE
(FT)
(PSI)
(GPM)
Pi
10.0
- - - -
9.1
- - -
P2
12.0
K= 3.00
7.1
8.0
P3
12.0
K= 3.00
7.2
8.1
P4
10.0
- - - -
9.4
- - -
1
10.5
- - - -
8.9
- - -
2
12.5
- - - -
7.0
- - -
3
12.5
- - - -
7.1
- - -
4
10.5
- - - -
9.1
- - -
A
12.5
- - - -
7.4
- - -
B
10.5
- - - -
8.9
- - -
B1
10.5
- - - -
9.1
- - -
C
10.5
- - - -
9.7
- - -
TOR
10.5
- - - -
10.3
- - -
FS1
4.0
- - - -
13.4
- - -
FS2
4.0
- - - -
16.4
- - -
BOR
0.5
- - - -
18.4
- - -
DOM
0.5
HOSE STREAM
19.3
5.0
UG
-3.0
- - - -
21.5
- - -
M
-3.0
SOURCE
23.0
21.0
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2
DATE: 8/14/20205&R LLC
RESIDENCE -
LA QUINTA
- CA
- JCP\AREA
2 2
HEAD.SDF
JOB
TITLE:
AREA
2 2HD
(12xl2)
(8 GPM)
PIPE
DATA
PIPE
TAG
Q(GPM)
DIA(IN) LENGTH
PRESS.
END
ELEV.
NOZ.
PT
DISC.
VEL(FPS)
HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI)
(GPM)
FL/FT
(PSI)
Pipe:
1
0.0
1.101
PL
0.50
PF
0.0
P1
10.0
0.0
9.1
0.0
0.0
150
FTG
E
PE
-0.2
1
10.5
0.0
8.9
0.0
0.000
TL
7.50
PV
Pipe:
2
-8.0
1.101
PL
0.50
PF
0.1
P2
12.0
3.0
7.1
8.0
2.7
150
FTG
T
PE
-0.2
2
12.5
0.0
7.0
0.0
0.012
TL
6.50
PV
Pipe:
3
-8.1
1.101
PL
0.50
PF
0.1
P3
12.0
3.0
7.2
8.1
2.7
150
FTG
T
PE
-0.2
3
12.5
0.0
7.1
0.0
0.013
TL
6.50
PV
Pipe:
4
0.0
1.101
PL
0.50
PF
0.0
P4
10.0
0.0
9.4
0.0
0.0
150
FTG
E
PE
-0.2
4
10.5
0.0
9.1
0.0
0.000
TL
7.50
PV
Pipe:
5
0.0
1.101
PL
9.75
PF
0.0
1
10.5
0.0
8.9
0.0
0.0
150
FTG
2TR
PE
0.0
B
10.5
0.0
8.9
0.0
0.000
TL
23.45
PV
Pipe:
6
-8.0
1.101
PL
8.00
PF
0.1
2
12.5
0.0
7.0
0.0
2.7
150
FTG
R
PE
0.0
3
12.5
0.0
7.1
0.0
0.012
TL
9.70
PV
Pipe:
7
-16.1
1.101
PL
1.50
PF
0.3
3
12.5
0.0
7.1
0.0
5.4
150
FTG
T
PE
0.0
A
12.5
0.0
7.4
0.0
0.045
TL
7.50
PV
Pipe:
8
0.0
1.101
PL
17.00
PF
0.0
4
10.5
0.0
9.1
0.0
0.0
150
FTG
ETR
PE
0.0
Bl
10.5
0.0
9.1
0.0
0.000
TL
31.70
PV
Pipe:
9
-8.2
1.101
PL
21.25
PF
0.6
A
12.5
0.0
7.4
0.0
2.7
150
FTG
2ET2R
PE
0.9
B
10.5
0.0
8.9
0.0
0.013
TL
44.65
PV
Pipe:
10
-8.2
1.101
PL
16.00
PF
0.3
B
10.5
0.0
8.9
0.0
2.7
150
FTG
2R
PE
0.0
Bl
10.5
0.0
9.1
0.0
0.013
TL
19.40
PV
Pipe:
11
-8.2
1.101
PL
29.00
PF
0.5
B1
10.5
0.0
9.1
0.0
2.7
150
FTG
T3R
PE
0.0
C
10.5
0.0
9.7
0.0
0.013
TL
40.10
PV
Pipe:
12
-7.9
1.101
PL
66.25
PF
1.3
A
12.5
0.0
7.4
0.0
2.7
150
FTG
3E3T3R
PE
0.9
C
10.5
0.0
9.7
0.0
0.012
TL
110.35
PV
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3
DATE: 8/14/2020S&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2 HEAD.SDF
JOB TITLE: AREA 2 2HD (12xl2) (8 GPM)
PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS.
END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM.
NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 13 -16.1 1.101 PL 6.25 PF 0.6
C 10.5 0.0 9.7 0.0 5.4 150 FTG E PE 0.0
TOR 10.5 0.0 10.3 0.0 0.045 TL 13.25 PV
Pipe: 14 -16.1 1.101 PL 6.50 PF 0.3
TOR 10.5 0.0 10.3 0.0 5.4 150 FTG ---- PE 2.8
FS1 4.0 0.0 13.4 0.0 0.045 TL 6.50 PV
Pipe: 15 FIXED PRESSURE LOSS DEVICE
FS2 4.0 0.0 16.4 0.0 3.0 psi, 16.1 gpm
FS1 4.0 0.0 13.4 0.0
Pipe: 16 -16.1 1.101 PL 3.50 PF 0.5
FS2 4.0 0.0 16.4 0.0 5.4 150 FTG C PE 1.5
BOR 0.5 0.0 18.4 0.0 0.045 TL 11.50 PV
Pipe: 17 -16.1 1.055 PL 2.00 PF 0.9
BOR 0.5 0.0 18.4 0.0 5.9 150 FTG 2ET PE 0.0
DOM 0.5 H.S. 19.3 5.0 0.056 TL 16.00 PV
Pipe: 18 -21.1 1.055 PL 3.50 PF 0.7
DOM 0.5 H.S. 19.3 5.0 7.7 150 FTG EG PE 1.5
UG -3.0 0.0 21.5 0.0 0.092 TL 7.50 PV
Pipe: 19 -21.0 1.394 PL 40.00 PF 1.5
UG -3.0 0.0 21.5 0.0 4.4 150 FTG 3E PE 0.0
M -3.0 SRCE 23.0 (N/A) 0.024 TL 64.00 PV
NOTES (HASS):
(1) Calculations were performed by the HASS 2020 D computer program
in accordance with NFPA13 (2016)
under license no. 64622225 granted by
HRS Systems, Inc.
208 Southside Square
Petersburg, TN 37144
(931) 659-9760
(2) The system has been calculated to provide an average
imbalance at each node of 0.008 gpm and a maximum
imbalance at any node of 0.137 gpm.
(3) Total pressure at each node is used in balancing the system.
Maximum water velocity is 7.7 ft/sec at pipe 18.
(4) Items listed in bold print on the cover sheet
are automatically transferred from the calculation report.
(5) Available pressure at source node M under full flow conditions is
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4
DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2 HEAD.SDF
JOB TITLE: AREA 2 2HD (12xl2) (8 GPM)
70.70 psi with a flow of 40.75 gpm.
(6) PIPE FITTINGS TABLE
HASS Pipe Table Name: standard.pip
PAGE: F
MATERIAL: CPVC
HWC: 150
Diameter
Equivalent Fitting Lengths
in Feet
(in)
F
E
T R K
C
G
F45
Ell
Tee RunT Kplg
ChkVly
Gate
1.101
1.40
7.00
6.00 1.70 1.00
8.00
0.40
1.394
1.80
8.00
7.30 2.30 1.00
11.00
0.80
PAGE: M
MATERIAL: CT-M
HWC: 150
Diameter
Equivalent Fitting Lengths
in Feet
(in)
E
T
F R K
C
G N
Ell
Tee 45-Ell
TeeRun Kouplg
ChkVly
GatVly NPTee
1.055
3.00
8.00
2.00 3.00 0.00
8.00
0.00 8.00
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5
DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2 HEAD.SDF
JOB TITLE: AREA 2 2HD (12xl2) (8 GPM)
WATER SUPPLY ANALYSIS
Fixed Source Pressure: 70.70 psi
SI 1
7010
60.0
G
A
U
50.0
G
E
p 40.0
R
E
S 30.0
S
U
R 2
20.0
E
-14.7
LEGEND
jAvailable pressure
70.70 psi @ 21.0 gpm
IRequired pressure
23.02 psi @ 21.0 gpm
A. Source Supply Curve
B. System Demand Curve
600900 1200 1500 1800 2100 2400 2700 3000
FLOW (GPM)
Note: (1) Dashed Lines indicate extrapolated values from Test Results
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6
DATE: 8/14/2020S&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2 HEAD.SDF
JOB TITLE: AREA 2 2HD (12x12) (8 GPM)
WATER SUPPLY CURVE
72+
I
I
66+
I
I
I
60+
I
I
I
54+
I
I
I
P 48+
R
E
S
S 42+
U
R
E
36+
( I
P
S
I 30+
I
I
I
24+
X
I
I
18+
I
I
12+
LEGEND
"
I"
X = Required Water Supply
"
23.02 psi @ 21.0 gpm
"
6+
"
0 = Available Water Supply
"
I"
70.70 psi @ 21.0 gpm
"
0++-+---+----+-----+------+--------+--------+---------+-----------+
8001200 1600 2000 2400
2800 3200 3600 4000
FLOW (GPM)
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1
DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1 HEAD.SDF
JOB TITLE: AREA 1 1HD (16xl6) (15 GPM)
WATER SUPPLY DATA
SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D
NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS.
TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI)
M (N/A) 70.7 (N/A) 70.7 20.0 39.9
Available pressure is 30.8 psi (44%) greater than required pressure.
AGGREGATE FLOW ANALYSIS:
TOTAL
FLOW AT SOURCE
20.0
GPM
TOTAL
HOSE STREAM ALLOWANCE AT SOURCE
0.0
GPM
OTHER
HOSE STREAM ALLOWANCES
5.0
GPM
TOTAL
DISCHARGE FROM
ACTIVE SPRINKLERS
15.0
GPM
NODE
ANALYSIS DATA
NODE
TAG ELEVATION
NODE TYPE
PRESSURE
DISCHARGE
(FT)
(PSI)
(GPM)
Pi
10.0
K= 3.00
25.0
15.0
P2
12.0
- - - -
25.7
- - -
P3
12.0
- - - -
25.7
- - -
P4
10.0
- - - -
26.6
- - -
1
10.5
- - - -
25.1
- - -
2
12.5
- - - -
25.4
- - -
3
12.5
- - - -
25.4
- - -
4
10.5
- - - -
26.3
- - -
A
12.5
- - - -
25.4
- - -
B
10.5
- - - -
26.0
- - -
B1
10.5
- - - -
26.3
- - -
C
10.5
- - - -
27.0
- - -
TOR
10.5
- - - -
27.6
- - -
FS1
4.0
- - - -
30.6
- - -
FS2
4.0
- - - -
33.6
- - -
BOR
0.5
- - - -
35.6
- - -
DOM
0.5
HOSE STREAM
36.4
5.0
UG
-3.0
- - - -
38.5
- - -
M
-3.0
SOURCE
39.9
20.0
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2
DATE: 8/14/20205&R LLC
RESIDENCE -
LA QUINTA
- CA
- JCP\AREA
1 1
HEAD.SDF
JOB
TITLE:
AREA
1 1HD
(16xl6)
(15 GPM)
PIPE
DATA
PIPE
TAG
Q(GPM)
DIA(IN) LENGTH
PRESS.
END
ELEV.
NOZ.
PT
DISC.
VEL(FPS)
HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI)
(GPM)
FL/FT
(PSI)
Pipe:
1
-15.0
1.101
PL
0.50
PF
0.3
P1
10.0
3.0
25.0
15.0
5.1
150
FTG
E
PE
-0.2
1
10.5
0.0
25.1
0.0
0.040
TL
7.50
PV
Pipe:
2
0.0
1.101
PL
0.50
PF
0.0
P2
12.0
0.0
25.7
0.0
0.0
150
FTG
T
PE
-0.2
2
12.5
0.0
25.4
0.0
0.000
TL
6.50
PV
Pipe:
3
0.0
1.101
PL
0.50
PF
0.0
P3
12.0
0.0
25.7
0.0
0.0
150
FTG
T
PE
-0.2
3
12.5
0.0
25.4
0.0
0.000
TL
6.50
PV
Pipe:
4
0.0
1.101
PL
0.50
PF
0.0
P4
10.0
0.0
26.6
0.0
0.0
150
FTG
E
PE
-0.2
4
10.5
0.0
26.3
0.0
0.000
TL
7.50
PV
Pipe:
5
-15.0
1.101
PL
9.75
PF
0.9
1
10.5
0.0
25.1
0.0
5.1
150
FTG
2TR
PE
0.0
B
10.5
0.0
26.0
0.0
0.040
TL
23.45
PV
Pipe:
6
0.0
1.101
PL
8.00
PF
0.0
2
12.5
0.0
25.4
0.0
0.0
150
FTG
R
PE
0.0
3
12.5
0.0
25.4
0.0
0.000
TL
9.70
PV
Pipe:
7
0.0
1.101
PL
1.50
PF
0.0
3
12.5
0.0
25.4
0.0
0.0
150
FTG
T
PE
0.0
A
12.5
0.0
25.4
0.0
0.000
TL
7.50
PV
Pipe:
8
0.0
1.101
PL
17.00
PF
0.0
4
10.5
0.0
26.3
0.0
0.0
150
FTG
ETR
PE
0.0
Bl
10.5
0.0
26.3
0.0
0.000
TL
31.70
PV
Pipe:
9
5.6
1.101
PL
21.25
PF
0.3
A
12.5
0.0
25.4
0.0
1.9
150
FTG
2ET2R
PE
0.9
B
10.5
0.0
26.0
0.0
0.006
TL
44.65
PV
Pipe:
10
-9.4
1.101
PL
16.00
PF
0.3
B
10.5
0.0
26.0
0.0
3.2
150
FTG
2R
PE
0.0
Bl
10.5
0.0
26.3
0.0
0.017
TL
19.40
PV
Pipe:
11
-9.4
1.101
PL
29.00
PF
0.7
B1
10.5
0.0
26.3
0.0
3.2
150
FTG
T3R
PE
0.0
C
10.5
0.0
27.0
0.0
0.017
TL
40.10
PV
Pipe:
12
-5.6
1.101
PL
66.25
PF
0.7
A
12.5
0.0
25.4
0.0
1.9
150
FTG
3E3T3R
PE
0.9
C
10.5
0.0
27.0
0.0
0.006
TL
110.35
PV
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3
DATE: 8/14/2020S&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1 HEAD.SDF
JOB TITLE: AREA 1 1HD (16x16) (15 GPM)
PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS.
END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM.
NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 13 -15.0 1.101 PL 6.25 PF 0.5
C 10.5 0.0 27.0 0.0 5.1 150 FTG E PE 0.0
TOR 10.5 0.0 27.6 0.0 0.040 TL 13.25 PV
Pipe: 14 -15.0 1.101 PL 6.50 PF 0.3
TOR 10.5 0.0 27.6 0.0 5.1 150 FTG ---- PE 2.8
FS1 4.0 0.0 30.6 0.0 0.040 TL 6.50 PV
Pipe: 15 FIXED PRESSURE LOSS DEVICE
FS2 4.0 0.0 33.6 0.0 3.0 psi, 15.0 gpm
FS1 4.0 0.0 30.6 0.0
Pipe: 16 -15.0 1.101 PL 3.50 PF 0.5
FS2 4.0 0.0 33.6 0.0 5.1 150 FTG C PE 1.5
BOR 0.5 0.0 35.6 0.0 0.040 TL 11.50 PV
Pipe: 17 -15.0 1.055 PL 2.00 PF 0.8
BOR 0.5 0.0 35.6 0.0 5.5 150 FTG 2ET PE 0.0
DOM 0.5 H.S. 36.4 5.0 0.049 TL 16.00 PV
Pipe: 18 -20.0 1.055 PL 3.50 PF 0.6
DOM 0.5 H.S. 36.4 5.0 7.3 150 FTG EG PE 1.5
UG -3.0 0.0 38.5 0.0 0.084 TL 7.50 PV
Pipe: 19 -20.0 1.394 PL 40.00 PF 1.4
UG -3.0 0.0 38.5 0.0 4.2 150 FTG 3E PE 0.0
M -3.0 SRCE 39.9 (N/A) 0.022 TL 64.00 PV
NOTES (HASS):
(1) Calculations were performed by the HASS 2020 D computer program
in accordance with NFPA13 (2016)
under license no. 64622225 granted by
HRS Systems, Inc.
208 Southside Square
Petersburg, TN 37144
(931) 659-9760
(2) The system has been calculated to provide an average
imbalance at each node of 0.006 gpm and a maximum
imbalance at any node of 0.096 gpm.
(3) Total pressure at each node is used in balancing the system.
Maximum water velocity is 7.3 ft/sec at pipe 18.
(4) Items listed in bold print on the cover sheet
are automatically transferred from the calculation report.
(5) Available pressure at source node M under full flow conditions is
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4
DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1 HEAD.SDF
JOB TITLE: AREA 1 1HD (16xl6) (15 GPM)
70.70 psi with a flow of 26.33 gpm.
(6) PIPE FITTINGS TABLE
HASS Pipe Table Name: standard.pip
PAGE: F
MATERIAL: CPVC
HWC: 150
Diameter
Equivalent Fitting Lengths
in Feet
(in)
F
E
T R K
C
G
F45
Ell
Tee RunT Kplg
ChkVly
Gate
1.101
1.40
7.00
6.00 1.70 1.00
8.00
0.40
1.394
1.80
8.00
7.30 2.30 1.00
11.00
0.80
PAGE: M
MATERIAL: CT-M
HWC: 150
Diameter
Equivalent Fitting Lengths
in Feet
(in)
E
T
F R K
C
G N
Ell
Tee 45-Ell
TeeRun Kouplg
ChkVly
GatVly NPTee
1.055
3.00
8.00
2.00 3.00 0.00
8.00
0.00 8.00
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5
DATE: 8/14/20205&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1 HEAD.SDF
JOB TITLE: AREA 1 1HD (16xl6) (15 GPM)
WATER SUPPLY ANALYSIS
Fixed Source Pressure: 70.70 psi
SI 1
7010
60.0
G
A
U
50.0
G
E
p 4020
R
E
S 30.0
S
U
R 20.0
E
10.0
p
s
i
0.0
-14.7
LEGEND
jAvailable pressure
70.70 psi @ 20.0 gpm
IRequired pressure
39.92 psi @ 20.0 gpm
A. Source Supply Curve
B. System Demand Curve
600900 1200 1500 1800 2100 2400 2700 3000
FLOW (GPM)
Note: (1) Dashed Lines indicate extrapolated values from Test Results
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6
DATE: 8/14/2020S&R LLC RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1 HEAD.SDF
JOB TITLE: AREA 1 1HD (16x16) (15 GPM)
WATER SUPPLY CURVE
72+
I
I
66+
I
I
I
60+
I
I
I
54+
I
I
I
P 48+
R
E
S
S 42+
U X
R
E
36+
( I
P
S
I 30+
I
I
I
24+
I
I
I
18+
I
I
12+
LEGEND
"
I"
X = Required Water Supply
"
39.92 psi @ 20.0 gpm
"
6+
"
0 = Available Water Supply
"
I"
70.70 psi @ 20.0 gpm
"
0++-+---+----+-----+------+--------+--------+---------+-----------+
8001200 1600 2000 2400
2800 3200 3600 4000
FLOW (GPM)
Page 1 of 6
® MICROFAST° QUICK 41RESPONSE PENDENT
SPRINKLER VK329 (K2.8)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
1. DESCRIPTION
The Viking Microfast® Quick Response Pendent Sprinkler VK329 is
a small thermosensitive glass bulb spray sprinkler available with various
finishes and temperature ratings to meet design requirements. The spe-
cial Polyester and Polytetrafluoroethelyne (PTFE) coatings can be used in
decorative applications where colors are desired. In addition, these coat-
ings have been investigated for installation in corrosive atmospheres and
are listed/approved as corrosion resistant as indicated in the Approval
Charts. (Note: FM Global has no approval classification for PTFE and Polyester
coatings as corrosion resistant.)
2. LISTINGS AND APPROVALS
c&s cULus Listed: Category VNIV
FM FM Approved: Class Series 2000
Refer to Approval Chart 1 and Design Criteria cULus Listing requirements,
and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed.
3. TECHNICAL DATA
Specifications:
Minimum Operating Pressure: 7 psi (0.5 bar)
Rated to 175 psi (12 bar) water working pressure
Factory tested hydrostatically to 500 psi (34.5 bar)
Thread size: 1/2" NPT, 15 mm BSP
Nominal K-Factor: 2.8 U.S. (40.3 metric**)
Glass -bulb fluid temperature rated to -65 °F (-55 °C) Viking Technical Data may be found on
Overall Length: 2-1/4" (58 mm) The Viking Corporation's Web site at
*cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). http://www.vikinggroupinc.com.
The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). The Web site may include a more recent
Material Standards: I edition of this Technical Data Page.
Frame Casting: Brass UNS-C84400 or QM Brass
Deflector: Brass UNS-C26000
Bushing: Brass UNS-C36000
Bulb: Glass, nominal 3 mm diameter
Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape
Screw: Brass UNS-C36000
Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400
For PTFE Coated Sprinklers: Belleville Spring -Exposed, Screw -Nickel Plated, Pip Cap-PTFE Coated
For Polyester Coated Sprinklers: Belleville Spring -Exposed
Ordering Information: (Also refer to the current Viking price list.)
Order Quick Response Upright and Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the
appropriate suffix for the temperature rating to the sprinkler base part number.
Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and Black PTFE = N
Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G
For example, sprinkler VK329 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12981AB
Available Finishes And Temperature Ratings: Refer to Table 1.
Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.)
Sprinkler Wrenches:
A. Standard Wrench: Part No. 10896W/B (available since 2000).
B. Wrench for Recessed Pendent Sprinklers: Part No. 16036W/B** (available since 2011)
C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010)
**A'/z' ratchet is required (not available from Viking).
***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808.
Form No. F_061714 16.01.28 Rev 16.1 Replaces form F_061714 Rev. 14.2 (Revised temperature suffix designation)
Page 2 of 6
® MICROFAST° QUICK 41RESPONSE PENDENT
SPRINKLER VK329 (K2.8)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Sprinkler Cabinets:
A. Six -head capacity: Part No. 01724A (available since 1971)
B. Twelve -head capacity: Part No. 01725A (available since 1971)
4. INSTALLATION
Refer to appropriate NFPA Installation Standards.
5. OPERATION
During fire conditions, the heat -sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and
sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern
to extinguish or control the fire.
6. INSPECTIONS, TESTS AND MAINTENANCE
Refer to NFPA 25 for Inspection, Testing and Maintenance requirements.
7. AVAILABILITY
The Viking Microfast° Quick Response Pendent Sprinkler VK329 is available through a network of domestic and international dis-
tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation.
8. GUARANTEE
For details of warranty, refer to Viking's current list price schedule or contact Viking directly.
Protective Sprinkler
Clip
Wrench Flat
Protective Sprinkler
Cap
i "'adih P10896 •
AMM
Figure 1: Standard Sprinkler Wrench 10896W/B
Form No. F_061714 16.01.28 Rev 16.1
Page 3 of 6
® MICROFAST° QUICK 41RESPONSE PENDENT
SPRINKLER VK329 (K2.8)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
TABLE 1:
AVAILABLE SPRINKLER TEMPERATURE
RATINGS AND FINISHES
Sprinkler Temperature
Sprinkler Nominal
Maximum Ambient
Bulb Color
Classification
Temperature Rating'
z
Ceiling Temperature
Ordinary
135 °F (57 °C)
100 °F (38 °C)
Orange
Ordinary
155 °F (68 °C)
100 °F (38 °C)
Red
Intermediate
175 °F (79 °C)
150 °F (65 °C)
Yellow
Intermediate
200 °F (93 °C)
150 °F (65 °C)
Green
High
286 °F (141 °C)
225 °F (107 °C)
Blue
Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and Black PTFE
Corrosion -Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE.
Footnotes
The sprinkler temperature rating is stamped on the deflector.
2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction.
Refer to specific installation standards.
s The corrosion -resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These
tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compat-
ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only.
Note that the spring is exposed on sprinklers with Polyester and PTFE coatings.
Sprinkler wrench 16036W/
for recessed pendent
sprinklers
** A 1/2" ratchet is require
(not available from Vikini
H
}
Carefully slide the wrench sideways around
the protective cap, ensuring engagement witt
the sprinkler wrench flats
Figure 2: Wrench 16036W/B for Recessed Pendent Sprinklers
Form No. F_061714 16.01.28 Rev 16.1
Page 4 of 6
® MICROFAST° QUICK
RESPONSE PENDENT
SPRINKLER VK329 (K2.8)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Approval Chart 1 (UL) Temperature KEY
The Viking Microfast® Quick Response W: Finis Neon
(if applicable)
Pendent Sprinkler VK329
Maximum 175 PSI (12 Bar) WWP
Base
Sprinkler
p
Thread Size
Nominal K-Factor
Overall Length
Listings and Approvals'
Part
SIN
(Refer also to Design Criteria.)
Number
Style
NPT ESP
U.S. I metricz
Inches
I mm
cULus° I VdS I LPCB I C L
12981
VK329 Pendent
1/2" 15 mm
2.8 40.3
2-1/4
58
A1Z, 61Y --
NOTICE
Office)
06718E
VK329 Pendent
1/2" 15 mm
2.8
40.3
2-3/16
56 A1Z, B1Y --
Approved Escutcheons
Approved Temperature Ratings
Approved Finishes
Y - Standard surface -mounted escutcheon or the
A- 135 °F (57 °C), 155 °F (68 °C), 175 °F (79
Viking Microfast® Model F-1 Adjustable Escutcheon, or
°C), 200 °F (93 °C), 286 °F (141 °C)
1 - BrassChrome, White
recessed with the Viking Micromatic° Model E-1, E-2, or
B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79
6
Polyester Black Polyester
E3 Recessed Escutcheon
°C), and 200 °F (93 °C)
and Black PTFE
Z - Standard surface -mounted escutcheon or the
Viking Microfast® Model F-1 Adjustable Escutcheon
Footnotes
Base part number shown. For complete part number, refer to Viking's current price schedule.
2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by
10.0.
3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process.
° Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada.
6 cULus Listed as corrosion -resistant.
6 Other colors are available on request with the same Listings and Approvals as the standard colors.
DESIGN CRITERIA - UL
(Also refer to Approval Chart 1 above.)
cULus Listing Requirements:
The Viking Microfast° Quick Response Pendent Sprinkler VK329 is cULus Listed as indicated in the Approval Chart for installation in
accordance with the latest edition of NFPA 13 for standard spray sprinklers.
• Small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically
calculated wet systems only.
• The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed.
IMPORTANT. Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page
QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor-
dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS
or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards,
whenever applicable.
Form No. F_061714 16.01.28 Rev 16.1
Page 5 of 6
® MICROFAST° QUICK 41RESPONSE PENDENT
SPRINKLER VK329 (K2.8)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Approval Chart 2 (FM) Temperature KEY
The Viking Microfast® Quick Response Finish
Pendent Sprinkler VK329 AIXFEscutcheon (if applicahle)
Maximum 175 PSI (12 Bar) WWP
Base Part
Sprinkler
Thread Size
Nominal K-Factor
Overall Length
FM Approvals'
Number'
SIN
Style
(Refer also to Design Criteria.)
NPT
BSP
U.S. metric2
Inches mm
12981
VK329
Pendent
112"
15 mm
2.8 40.3
2-1/4 1 58
A1Z
NOTICE..
Office)
16718B
VK329
I Pendent 1 112"
15 mm
2.8
40.3
2-3/16 1 56
1 A1Z
Approved Temperature Ratings
Approved Finishes
Approved Escutcheons
A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 -F
1 - Brass and Chrome
Z - Standard surface -mounted escutcheon or the
(93 °C), 286 °F (141 °C)
Viking Microfast® Model F-1 Adjustable Escutcheon
Footnotes
Base part number shown. For complete part number, refer to Viking's current price schedule.
2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by
10.0.
s This table shows the FM Approvals available at the time of printing. Other approvals may be in process.
^ Other colors are available on request with the same Approvals as the standard colors.
DESIGN CRITERIA - FM
AGE I
(Also refer to Approval Chart 2 above.)
FM Approval Reauirements:
The Viking Microfast® Quick Response Pendent Sprinkler VK329 is FM Approved as quick response Non -storage upright and pendent
sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable
FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but
not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable
spacing, and deflector distance below the ceiling.
NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria.
IMPORTANT. Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page
QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac-
cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB,
APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and
standards, whenever applicable.
Form No. F_061714 16.01.28 Rev 16.1
Page 6 of 6
® MICROFAST° QUICK
RESPONSE PENDENT
N4 I KJ SPRINKLER VK329 (K2.8)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
1 /2"
(15 mm)
NPT`
t —
All'
2-1/4"
(57 mm)
i
.l �r—
T
1-3/4"
(44.5 mm
Installed with a standard
1/8" surface -mounted
escutcheon
Ceiling Opening Size:
2-516/" (58.7 mm) minimum
2-1/2" (63.5 mm) maximum
2-1/8"
(54 mm)
I&A.
1-1/2"
2"I (38 mm)
(51 mm) Min.
Max.
Installed with a Microfast Note: At maximum, adapter is
Model F-1 Adjustable exposed 1/2" (12.7 mm) from
Escutcheon face of ceiling
Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon
ANEW Ceiling Opening Size:
2-516/" (58.7 mm) minimum
2-1/2" (63.5 mm) maximum
2-1/8"
2-1/8"
(54 mm)
(54 mm)
1 3/4
(44.5 mm)
Max.
(28.6 mm)
Min.
2 (28.6 mm)
(51 mm) � , Min.
Max.
Installed with a
Installed with a Model
Model E-1 Recessed
E-2 Thread -on Recessed
Escutcheon
Escutcheon
Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons
Form No. F_061714 16.01.28 Rev 16.1 Replaces form F_061714 Rev. 14.2 (Revised temperature suffix designation)
Page 1 of 5
N4 I KJ® FREEDOM® RESIDENTIAL
CONCEALED PENDENT
SPRINKLER VK496 (K3.0)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
DESCRIPTION
Viking Freedom") Residential Concealed Pendent Sprinkler VK496 is a small
thermosensitive, glass -bulb residential sprinkler designed for installation on concealed
pipe systems where the appearance of a smooth ceiling is desired. The orifice design,
with a K-Factor of 3.0 (43.2 metric*), allows the sprinkler's efficient use of available
water supplies for the hydraulically designed fire -protection system. The fast
response glass bulb operating element and special deflector characteristics meet
the challenges of residential sprinkler standards.
The sprinkler is pre -assembled with a threaded adapter for installation with a
low -profile small -diameter cover assembly installed flush to the ceiling. The two-
piece design allows installation and testing of the sprinkler prior to installation
of the cover plate. The "push -on", "thread -off' design of the concealed cover
plate assembly allows easy installation of the cover plate after the system has
been tested and the ceiling finish has been applied, while also providing up to
1/2" (13 mm) of vertical adjustment. The cover assembly can be removed and
reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler
system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT)
coating has been investigated for installation in corrosive atmospheres and is C-UL-
US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT
finish is only available for the sprinkler assembly, the cover plate is not plated.
2. LISTINGS AND APPROVALS
e&s UL Listed (C-UL-US-EU): Category VKKW
Eu Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing
requirements that must be followed.
3. TECHNICAL DATA
Specifications:
Minimum Operating Pressure: Refer to the Approval Chart.
Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500
psi (34.5 bar).
Thread size: 1/2" (15 mm) NPT
Nominal K-Factor: 3.0 U.S. (43.2 metric*)
Glass -bulb fluid temperature rated to -65 °F (-55 °C)
* Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric
K-factor shown by 10.0.
Material Standards:
Sprinkler Body: Brass UNS-C84400 or QM Brass
Deflector: Phosphor Bronze UNS-051000
Deflector Pins: Stainless Steel UNS-S30200
Button: Brass UNS-C31600
Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400
Compression Screw: 18-8 Stainless Steel
Yoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-051000
Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape
Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating
Shipping Cap: Polyethylene
Cover Plate Materials:
Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800
Spring: Beryllium Nickel
Solder: Eutectic
Available Finishes and Temperature Ratings:
Finish
Brass
ENT
Suffix
A
JN
Temperature
155 *F (68 *C)
200*F (93 *C)
Suffix
B
E
Ordering Information: Refer to Tables 1 and 2.
WARNING: Cancer and Reproductive Harm-
www. P65Warni ngs.ca.gov
Form No. F_032218 19.03.21 Rev 19.1 New page.
Page 2 of 5
N4 I Kj® FREEDOM® RESIDENTIAL
CONCEALED PENDENT
SPRINKLER VK496 (K3.0)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
4. INSTALLATION
Refer to appropriate NFPA Installation Standards.
5. OPERATION
During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches,
releasing the deflector. Continued heating of the exposed sprinkler causes the heat -sensitive liquid in the glass bulb to expand,
causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly. Water flowing through the sprinkler orifice
strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pressure at
the sprinkler to extinguish or control the fire.
6. INSPECTIONS, TESTS AND MAINTENANCE
Refer to NFPA 25 for Inspection, Testing and Maintenance requirements.
7. AVAILABILITY
Viking Sprinkler Model VK496 is available through a network of domestic and international distributors. See The Viking Corporation
web site for the closest distributor or contact The Viking Corporation.
8. GUARANTEE
For details of warranty, refer to Viking's current list price schedule or contact Viking directly.
TABLE 1: ORDERING
Instructions: Using the
•R•
sprinkler base part number,
.. the suffix
the suffix for
Order a cover
for the desired..
the desired Temperature Rating.
plate
Size
1: Finishes
2: Temperature Ratings
Sprinkler
Description
Suffix,
Nominal Rating
Bulb Color
Max. Ambient Ceiling
Suffix
Base Part NPT BSPT
No.
Inch mm
Temperature
22773 1/2
--
Brass
A
155 °F (68 °C)
Red
100 °F (38 °C)
B
ENT 3,4
JN
200 °F (93 °C)
Green
150 °F (65 °C)
E
Example: 22773AE =
200 °F (93 °C) Temperature Rated Sprinkler
with a standard Brass finish.
Accessories
Sprinkler Wrenches (see Figure 1):
A. Heavy Duty Part Number: 14047WB5
B. Head Cabinet Wrench Part Number: 140311
Sprinkler Cabinet:
Part number 01731A.
Footnotes
I Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above.
z. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having
Jurisdiction. Refer to specific installation standards.
3. LIL Listed as corrosion resistant.
4. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and
do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed
environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway.
5. Requires a 1/2" ratchet which is not available from us.
6. Optional for removal of the protective cap. Ideal for sprinkler cabinets.
Form No. F_032218 19.03.21 Rev 19.1
Page 3 of 5
N4 I Kj® FREEDOM® RESIDENTIAL
CONCEALED PENDENT
SPRINKLER VK496 (K3.0)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
COVERTABLE 2: ORDERING INFORMATION
Instructions: Using the cover plate base part number,
.. the suffix for the desired Finish
.. the suffix for the required Cover Plate Nominal Rating.
1: Finishes Temperature Rating Matrix' z
Cover Plate Size
Cover Plate
Sprinkler
Sprinkler Max.
Base Part Style
Inch (mm)
Number
Description
Suffixs
N urinal
Nominal Rating
AmbienTemper
Suffix
(Required)
tubing
13504 2-3/4 (70) Round
Polished Chrome
F
135 °F (57 °C)
155 °F (68 °C)
100 °F (38 °C)
A
13642 3-5/16 (84) Round
Brushed Chrome
F-/B
165 °F (73 °C)3
200 °F (93 °C)
150 °F (65 °C)
C
15394 3-5/16 (84) Square
Bright Brass
B
Corrosion Resistant Sprinkler Coating: ENT
Antique Brass
B-/A
Brushed Brass
B-/B
Brushed Copper
E-/B
Example: 13504MA/W =
Painted White
M-/W
135 °F (57 °C) Temperature Rated 2-3/4" (70 mm) Diameter
Round Cover Plate with a Painted White finish.
Painted Ivory
MA
Painted Black
M-/B
Footnotes
1 The sprinkler temperature rating is stamped on the deflector.
s. Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having
Jurisdiction. Refer to specific installation standards.
3. Maximum ambient temperature for cover assembly is 100 °F (38 °C).
4. Part number shown is the base part number. For complete part number, refer to current our price list schedule.
5. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and
do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed
environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville
spring is exposed.
6. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above.
Form No. F_032218 19.03.21 Rev 19.1
Page 4 of 5
® FREEDOM® RESIDENTIAL
CONCEALED PENDENT
SPRINKLER VK496 (K3.0)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
APPROVAL CHART
VK496, 3.0 K-Factor Residential Concealed Pendent Sprinkler
For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to
current editions of NFPA 13, 13R or 13D
Sprinkler Base
Thread Size
Nominal K-Factor
Part Number I
SIN
Maximum Water Working Pressure
Inches
mm
U.S.
metric z
22773
VK496
1/2
15
3.0
43.2
175 psi (12 bar)
Maximum
Listings and
Coverage Area 5
All Temperatures
Deflector
A rovals3
pp
Minimum Spacing
W X L
to Ceiling
Installation Type
Ft.
Flow
Pressure
Ft. X Ft.
(m)
(m X m)
gpm (Lpm)
PSI (bar)
c@us4
Eu
12 X 12
8
7.1
(3.7 X 3.7)
(30.3)
(0.49)
Refer to
Concealed with Cover
See Footnotes 3, 4, and 8
8
14 X 14
12
16
(4.3 X 4.3)
(45.4)
(1.1)
Figure 2
Plate Assembly. See
Footnotes 6 & 7.
(2.4 )
16 X 16
15
25
(4.9 X 4.9)
(56.8)
(1.72)
Footnotes
I. Part number shown is the base part number. For complete part number, refer to current our price schedule.
Y. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
I This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approv-
als. Refer also to Design Criteria.
a Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union.
5. For areas of coverage smaller than shown, use the "Flow' and "Pressure" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from
sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow" and "Pressure' used.
5. Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking
for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3.
7 Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or
Painted Black 6.
s. C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT)
Form No. F_032218 19.03.21 Rev 19.1
Page 5 of 5
N4 I Kj® FREEDOM® RESIDENTIAL
CONCEALED PENDENT
SPRINKLER VK496 (K3.0)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
DESIGN CRITERIA
(Also refer to the Approval Chart on page 3.)
UL Listing Reguirements (C-UL-US-EU):
When using Viking Residential Concealed Pendent Sprinkler VK496 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover-
age and minimum water supply requirements shown in the Approval Chart.
For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum
required discharge from each of the four sprinklers is to be the greater of the following:
• The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or
• Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area" in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13.
• Minimum distance between residential sprinklers: 8 ft. (2.4 m).
NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only.
IMPORTANT. Always refer to Bulletin Form No. F 080415 - Best Practices for Residential Sprinkler Handling and Installation.
Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be in-
stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar
Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever
applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities
Having Jurisdiction.
Sprinkler and Adapter Assembly
• Protective cap removed
• Use wrench 14047W/B**
Sprinkler Wrench
Part No. 14047W/B**
Step 1:
Carefully slide the
wrench sideways around
the deflector and pins
NEVER install the sprinkler by applying the installation
wrench across the frame arms. DO NOT overtighten.
Use only the designated sprinkler wrenches, Viking
Part Numbers 14047W/B** or 14031**. A leak tight seal
should be achieved by turning the sprinkler clockwise
1 to 1-1/2 turns beyond finger tight.
2-1/4" (57 mm)
diameter opening
required in the
ceiling.
Step 2: 1 1
Carefully press the wrench upward and
turn slightly to ensure engagement with
the sprinkler wrench flats.
Sprinkler
wrench flat
Figure 1: Sprinkler Installation and Proper Wrench Usage
** A 1/2" ratchet is required (Not available from Viking)
Sprinkler
frame arms
Form No. F_032218 19.03.21 Rev 19.1
Page 6 of 5
® FREEDOM° RESIDENTIAL
4 I Ki CONCEALED PENDENT
SPRINKLER VK496 (K3.0)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
1/2" (15 mm) NPT
E
CV co
LO
2-9/16" (65 mm)
Maximum
NOTE: Upon sprinkler activation, the deflector descends
to approximately 13116" (21 mm) below the sprinkler body.
2-1/16" (52 mm)
Minimum
Figure 2: Sprinkler Dimensions and Cover Installation
All custom color painted cover plates will have an
identifying label affixed to the inside of the cover that
indicates the custom color and will have a representative
sample (a paint dot) of the paint on the label.
Figure 3: Identification of Custom Paint for Concealed Covers
2-3/4" (70 mm) or
3-5/16" (84 mm)
J
3-5/16" (84 mm)
Figure 4: Square Cover Assembly 15394
Form No. F_032218 19.03.21 Rev 19.1 New page.
tqCtj Fire &Building
Products
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500
BlazeMaster °
CPVC Fire Sprinkler Pipe & Fittings
Submittal Sheet
General
Description
Tyco Fire & Building Products (TFBP)
BlazeMaster CPVC Pipe and Fittings
are designed exclusively for use in wet
pipe automatic fire sprinkler systems.
They are made from a specially devel-
oped thermoplastic compound com-
posed of post chlorinated polyvinyl
chloride (CPVC) resin and state of the
art additives. TFBP BlazeMaster
CPVC products are easier to install
than traditional steel pipe systems,
and at the same time, provide superior
heat resistance and strength as com-
pared to traditional CPVC and PVC
piping materials used in the plumbing
trade. Various adapters are available
to connect CPVC pipe to metallic pip-
ing. All female pipe thread adapters
have brass inserts for durability.
Grooved adapters connect directly to
grooved end valves and metallic pipe,
with flexible grooved end couplings.
WARNING
Tyco Fire & Building Products (TFBP)
BlazeMaster CPVC Pipe and Fittings
described herein must be installed and
maintained in compliance with this
document, as well as with the applica-
ble standards of the National Fire Pro-
tection Association, in addition to the
standards of any other authorities hav-
ing jurisdiction. Failure to do so may
impair the performance of these de-
vices.
The owner is responsible for maintain-
ing their fire protection system and de-
vices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted
with any questions.
Technical
Da to
Sizes
3/4" to 3"
Maximum Working Pressure
175 psi
Approvals
UL, FM, CUL, NSF, Dade County,
LPCB, MEA, and the City of Los Ange-
les. (Refer to IH-1900, Rev. 0, Janu-
ary 2005 "Installation Instruction &
Technical Handbook" for exact list-
ing/approval information.)
Manufacture Source
U.S.A.
Material
❑ Pipe: ASTM F442, SDR 13.5
❑ Fittings: ASTM F438 (Sch. 40) and
ASTM F439 (Sch. 80), ASTM F1970
Color
Orange
An
rapid reap insets
HOME FIRE SPRINKLER SYSTEM
BlazeMasteO) is a registered trademark
of Noveon IP Holding Corp.
Page 1 of 6 JANUARY, 2006 TFP1915
Page 2 of 6
TFP1915
WATER
NOMINAL
AVERAGE
AVERAGE
WEIGHT
FILLED WEIGHT
FT. OF PIPE
WEIGHT PER LIFT
SIZE
O.D.
I.D.
Ibs./ft.
Ibs./ft.
PER LIFT
Ibs.
3/4"
1.050"
0.874"
0.18
0.44
7875
1339
1"
1.315"
1.101,
0.26
0.67
5040
1320
1-1/4"
1.660"
1.394"
0.42
1.08
2835
1191
1-1/2"
1.9001,
1.598"
0.54
1.41
2205
1213
2"
2.375"
2.003"
0.84
2.20
1260
1084
2-1/2"
2.875"
2.423"
1.26
3.26
1215
1531
3"
3.500"
2.952"
1.87
4.83
720
1344
Installation
Tyco Fire and Building Products
(TFBP) BlazeMaster CPVC Pipe and
Fittings are to be installed in accord-
ance with IH-1900, Rev. 0, January
2005 "Installation Instruction & Techni-
cal Handbook".
FIGURE 1 — PIPE DIMENSIONS
Care and
Maintenance
The owner is responsible for the in-
spection, testing, and maintenance of
their fire protection system and de-
vices in compliance with this docu-
ment, as well as with the applicable
standards of the National Fire Protec-
tion Association (e.g., NFPA 25), in
addition to the standards of any
authority having jurisdiction. The in-
stalling contractor or product manufac-
turer should be contacted relative to
any questions.
It is recommended that automatic
sprinkler systems be inspected,
tested, and maintained by a qualified
Inspection Service in accordance with
local requirements and/or national
codes.
NOTES
Before closing a fire protection system
control valve for inspection or mainte-
nance work on the fire protection sys-
tem that it controls, permission to shut
down the affected fire protection sys-
tem must first be obtained from the
proper authorities and all personnel
who may be affected by this action
must be notified.
After placing a fire protection system
in service, notify the proper authorities
and advise those responsible for moni-
toring proprietary and/or central sta-
tion alarms.
TFP1915
Page 3 of 6
FITTING
PART
NOMINAL SIZE
NOMINAL TAKE-OUT
SCHD.
WEIGHT
TYPE
NUMBER
(T/O)
(lb.)
TEE
80000
3/4"
5/8"
40
0.11
T/O
80001
1"
11/16"
40
0.19
80002
1-1/4"
7/8"
40
0.26
80003
1-1/2"
1-1/16"
80
0.51
80004
2"
1-3/8"
80
0.90
80005
2-1/2"
1-9/16"
80
1.59
T/O
T/O
80006
3"
1-13/16"
80
2.41
XxYxZ
X
Y
Z
3/4" x 3/4" x 1"
3/4"
3/4"
5/8"
80132
40
0.14
80133
1" x 3/4" x 3/4"
9/16"
9/16"
3/4"
40
0.14
80134
1" x 3/4" x 1"
3/4"
11/16"
3/4"
40
0.17
80260
1" x 1" x 3/4"
5/8"
5/8"
13/16"
40
0.16
80135
1-1/4" x 1" x 3/4"
5/8"
5/8"
15/16"
40
0.21
80136
1-1/4" x 1" x 1"
3/4"
3/4"
15/16"
40
0.22
80137
1-1/4" x 1" x 1-1/4"
15/16"
15/16"
7/8"
40
0.26
REDUCING TEE
80261
1-1/4" x 1-1/4" x 3/4"
5/8"
5/8"
7/8"
40
0.23
80262
1-1/4" x 1-1/4" x 1"
3/4"
3/4"
7/8"
40
0.26
Z
80138
1-1/4" x 1-1/4" x 1-1/2"
1"
1"
1"
80
0.43
T/O
80140
1-1/2" x 1-1/4" x 3/4"
9/16"
9/16"
1"
80
0.36
80141
1-1/2" x 1-1/4" x 1"
9/16"
9/16"
1-1/16"
80
0.38
80263
80264
1-1/2" x 1-1/2" x 3/4"
1-1/2" x 1-1/2" x 1"
9/16"
9/16"
9/16"
9/16"
1"
1-1/16"
80
80
0.36
0.38
X Y
80275
1-1/2" x 1-1/2" x 1-1/4"
7/8"
7/8"
1"
80
0.45
T/O T/O
80265
2" x 2" x 3/4"
3/4"
3/4"
1-3/8"
80
0.61
80266
2" x 2" x 1"
7/8"
7/8"
1-3/8"
80
0.66
80274
2" x 2" x 1-1/4"
1-1/16"
1-1/16"
1-3/8"
80
0.74
80267
2" x 2" x 1-1/2"
1-1/8"
1-1/8"
1-3/8"
80
0.78
80271
2-1/2" x 2-1/2" x 1"
1-9/16"
1-9/16"
1-9/16"
80
1.43
80272
2-1/2" x 2-1/2" x 1-1/4"
1-9/16"
1-9/16"
1-9/16"
80
1.46
80273
2-1/2" x 2-1/2" x 1-1/2"
1-9/16"
1-9/16"
1-9/16"
80
1.48
80276
2-1/2" x 2-1/2" x 2"
1-9/16"
1-9/16"
1-9/16"
80
1.50
80270
3" x 3" x 1-1/2"
1-13/16"
1-13/16"
1-13/16"
80
2.28
80268
3" x 3" x 2"
1-13/16"
1-13/16"
1-3/4"
80
2.25
80269
3" x 3" x 2-1/2"
1-13/16"
1-13/16"
1-13/16"
80
2.44
CROSS & REDUCING
CROSS
80009
3/4"
9/16"
40
0.13
T/O
80010
1"
11/16"
40
0.23
80011
1-1/4"
15/16"
40
0.34
80012
1-1/2"
1-1/16"
80
0.67
80013
2"
1-5/16"
80
1.00
80014
2-1/2"
1-9/16"
80
1.91
T/O
80008
3"
1-13/16"
80
2.89
80015
1" x 1" x 3/4" x 3/4"
7/8"
40
0.28
T/O
T/0
80025
3/4"
5/8"
40
0.09
90' ELBOW &
REDUCING ELBOW
80026
1"
3/4"
40
0.14
80027
1-1/4"
7/8"
40
0.21
X
80028
1-1/2"
1-1/16"
80
0.40
T/O
80029
2"
1-5/16"
80
0.79
80030
2-1/2"
1-9/16"
80
1.14
Y
80031
3"
1-13/16"
80
1.82
XxY
X
Y
T/O
E80032
1" x 3/4"
11116"
13/16"
40
0.16
FIGURE 2 - FITTING DIMENSIONS (Part 1 of 4)
Page 4 of 6
TFP1915
FITTING
PART
NOMINAL SIZE
NOMINAL TAKE-OUT
SCHD.
WEIGHT
TYPE
NUMBER
(T/O)
(lb.)
45" ELBOW
80050
3/4"
3/8"
40
0.08
T/O
80051
1"
3/8"
40
0.11
80052
1-1/4"
3/4"
40
0.20
80053
1-1/2"
1/2'
80
0.31
T/O,!!!�
80054
2"
3/4"
80
0.56
80055
2-1/2"
13/16"
80
0.89
80056
3"
1"
80
1.19
80075
3/4"
1/8"
40
0.07
COUPLING &
80076
1"
1/8"
40
0.11
REDUCING COUPLING
80077
1-1/4"
3/16"
40
0.12
80078
1-1/2"
3/16'
80
0.25
80079
2"
3/16"
80
0.38
80080
2-1/2"
1/4"
80
0.67
T/O
80081
3"
3/16"
80
0.91
80220
1" x 3/4"
1/8"
40
0.08
80200
1" x 3/4"
7/16"
40
0.04
80201
1-1/4" x 3/4"
1/2"
40
0.11
80202
1-1/4" x 1"
5/16"
40
0.12
80203
1-1/2" x 3/4"
5/8"
80
0.16
80204
1-1/2" x 1"
1/2"
80
0.14
REDUCER BUSHING
80205
1-1/2" x 1-1/4"
3/8"
80
0.17
80206
2" x 3/4"
13/16"
80
0.27
80207
2" x 1"
11/16'
80
0.26
80208
2" x 1-1/4"
9/16"
80
0.24
80209
2"x1-1/2"
7/16"
80
0.19
T/O
80215
2-1/2" x 1"
15/16"
80
0.42
80214
2-1/2" x 1-1/4"
13/16"
80
0.45
80213
2-1/2" x 1-1/2"
11/16"
80
0.46
80211
2-1/2" x 2"
5/8"
80
0.29
80210
3" x 2"
3/4"
80
0.72
80212
3" x 2-1/2"
1/2"
80
0.47
CAP
80100
3/4"
5/16"
40
0.04
80101
1"
3/8"
40
0.06
80102
1-1/4"
7/16"
40
0.10
80103
1-1/2"
11/16"
80
0.20
80104
2"
5/8"
80
0.31
T/O
80105
2-1/2"
7/8"
80
0.58
80106
3"
1"
80
0.88
GROOVED
T/O
PIPE O.D.
COUPLING ADAPTER
2-5/16"
1-1/4" (1.660")
80160
1-1/4" x 1-1/4" Groove
40
0.78
80161
1-1/2" x 1-1/2" Groove
2-5/16"
1-1/2" (1.900")
80
0.95
PIPE
80162
2" x 2" Groove
2-5/16"
2" (2.375")
80
1.42
O.D.
80163
2-1/2" x 2-1/2" Groove
2-5/16"
2-1/2" (2.875")
80
2.28
80164
3" x 3" Groove
2-1/4"
3" (3.500")
80
3.00
T/O -I
80169
2-1/2" x 76,1 mm Groove
2-5/16"
76,1 mm (3.000")
80
2.28
FIGURE 2 - FITTING DIMENSIONS (Part 2 of 4)
TFP1915
Page 5 of 6
FITTING
PART
NOMINAL TAKE-OUT
WEIGHT
TYPE
NUMBER
NOMINAL SIZE
(TKO)
SCHD.
(lb.)
SPRINKLER HEAD
ADAPTER
80175E
3/4" x 112" NPT
7/16"
80
0.20
80176E
1" x 1/2" NPT
7/16"
80
0.22
;_T/0
80175WL
3/4" x 1/2" NPT
7/16"
40
0.16
80179
1" x 3/4" NPT
13/16"
40
0.43
SPRINKLER HEAD
ADAPTER
80175W
3/4" x 112" NPT
1/2"
40
0.19
T/O
80176W
1" x 1/2" NPT
1/2"
40
0.18
SPRINKLER HEAD
ADAPTER (SPIGOT)
80177L
3/4" x 1/2" NPT
1/2"
40
0.16
80178
1" x 1/2" NPT
9/16"
40
0.20
80180
1"x 3/4" NPT
7/8"
40
0.40
T/O
FEMALE ADAPTER
80142
3/4" x 3/4" NPT
13/16"
40
0.41
80145
1' x 1" NPT
7/8"
40
0.63
80146
1-1/4" x 1-1/4" NPT
1-1/8"
40
1.03
80147
1-1/2" x 1-1/2" NPT
1-3/8"
80
1.42
80148
2" x 2" NPT
1-11/16"
80
2.66
—T/O
MALE ADAPTER
80157
3/4" x 3/4" NPT
1-5/16"
40
0.33
80158
1' x 1" NPT
1-3/8"
40
0.56
—T/O —
XxYxZ
X
Y
Z
SPRINKLER HEAD
ADAPTER TEE
80250
3/4" x 3/4" x 1/2" NPT
9/16"
9/16"
1"
40
0.22
Z
80251
1" x 1" x 1/2" NPT
11/16"
11/16"
1-3/16"
40
0.29
T/O
80249
1" x 1" x 1" NPT
15/16"
15/16"
1-9/16"
40
0.73
80256
1-1/4" x 1" x 1/2" NPT
7/16"
9/16"
1-5/16"
40
0.30
80252
1-1/4" x 1-1/4" x 1/2" NPT
7/16"
7/16"
1-5/16"
40
0.31
80257
1-1/2" x 1-1/4" x 1/2" NPT
1/2"
11/16"
1-7/16"
80
0.43
X Y l
�=T/10
80254
1-1/2" x 1-1/2" x 1/2" NPT
1/2"
1/2"
1-7/16"
80
0.46
T/O
80258
2" x 1-1/2" x 1/2" NPT
1/2"
5/8"
1-11/16"
80
0.56
80253
2" x 2" x 1/2" NPT
1/2"
1/2"
1-11/16"
80
0.62
FIGURE 2 — FITTING DIMENSIONS (Part 3 of 4)
Page 6 of 6
TFP1915
FITTING
TYPE
PART
NUMBER
NOMINAL SIZE
NOMINAL TAKE-OUT
(T/O)
SCHD.
WEIGHT
(Ib.)
BACK-TO-BACK TEE
X x Y x Z
X
Y, Z
X
T/O
4j
Y 1
80459
1" x 1/2" NPT x 1/2" NPT
5/8"
1-5/16"
40
0.48
80460
1" x 1/2" NPT x 1/2" NPT
5/8"
1-3/16"
40
0.46
Z
T/O
T/O
BACK-TO-BACK CROSS
X X Y X Z X W
X, Y
Z, W
X
T/O
i
iZ
80462
1" x 1" x 1/2" NPT x 1/2" NPT
5/8"
1-3/16"
40
0.46
w}
I
80463
1" x 1" x 1/2" NPT x 1/2" NPT
5/8"
1-5/16"
40
0.47
T/O
Y
T/O
T/O
SPRINKLER HEAD
X x Y
X
Y
ADAPTER 90° ELBOW
Y
T/O
80199
3/4" x 1/2" NPT
9/16"
1"
40
0.20
80198
1" x 1/2" NPT
3/4"
1-1/4"
40
0.26
X I
80196
1" x 3/4" NPT
1-1/16"
1-7/16"
40
0.26
— T/O
FIGURE 2 — FITTING DIMENSIONS (Part 4 of 4)
Limited
Warranty
Products manufactured by Tyco Fire &
Building Products (TFBP) are war-
ranted solely to the original Buyer for
ten (10) years against defects in mate-
rial and workmanship when paid for
and properly installed and maintained
under normal use and service. This
warranty will expire ten (10) years
from date of shipment by TFBP. No
warranty is given for products or com-
ponents manufactured by companies
not affiliated by ownership with TFBP
or for products and components which
have been subject to misuse, improper
installation, corrosion, or which have
not been installed, maintained, modi-
fied or repaired in accordance with ap-
plicable Standards of the National Fire
Protection Association, and/or the
standards of any other Authorities
Having Jurisdiction. Materials found
by TFBP to be defective shall be either
repaired or replaced, at TFBP's sole
option. TFBP neither assumes, nor
authorizes any person to assume for it,
any other obligation in connection with
the sale of products or parts of prod-
ucts. TFBP shall not be responsible for
sprinkler system design errors or inac-
curate or incomplete information sup-
plied by Buyer or Buyer's repre-
sentatives.
In no event shall TFBP be liable, in
contract, tort, strict liability or under
any other legal theory, for incidental,
indirect, special or consequential dam-
ages, including but not limited to labor
charges, regardless of whether TFBP
was informed about the possibility of
such damages, and in no event shall
TFBP's liability exceed an amount
equal to the sales price.
The foregoing warranty is made in lieu
of any and all other warranties, ex-
press or implied, including warranties
of merchantabilitv and fitness for a Dar -
This limited warranty sets forth the ex-
clusive remedy for claims based on
failure of or defect in products, materi-
als or components, whether the claim
is made in contract, tort, strict liability
or any other legal theory.
This warranty will apply to the full ex-
tent permitted by law. The invalidity, in
whole or part, of any portion of this
warranty will not affect the remainder.
TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446
Pipe Clamps
v
'6.
m
n
iv
3
N�
TOLCOT" Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe
Size Range: Available in 3/4" (20mm) and 1" (25mm) pipe sizes
Material: Pre -Galvanized Steel
Function: Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler
pipe. Provides double offset 11/2" (20mm) x 11/2" (20mm) from mounting surface. This design
will ease installation by eliminating the need for wood block extension and allow retro-fit
attachment of hanger to sprinkler pipe.
Features:
• Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not
required to be bent for listed installation.
• Offset edge eliminates abrasion.
• Attaches easily to wood structure with two special #10 x 1 " hex head self -threading
screws furnished with product.
• Can be used as a single offset hanger by aligning "dimples" with top of mounting
surface and utilizing two fasteners in two of the three holes provided.
Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) as a
hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of
NFPA 13, 13R and 13D.
Finish: Pre -Galvanized
Order By: Part number and pipe size.
Patent Pending
Pipe Size Approx. Wt./100
Part No. in. (mm) lbs. (kg)
29-3/4 3/4" (20) 17.0 (7.7)
29-1 1" (25) 18.6 (8.4)
Double Offset
to
Single Offset
(38.1mm)
�O O CC.
0
7
on
o
C
(38.1mm)
I:@"
LISTED
ll (38.1mm)
I---------- ,
1.5"
(38.1mm)
Install using a rechargeable electric drill fitted with a 5/16" (7.9mm) socket attachment with the special hex head self -tapping
screws provided. Install screws until they bottom out. Pipe can be "snapped" into hanger before or after installation of
the screws to the mounting surface. "Thumb tab" may be bent up to provide additional protection to the pipe, but is not
required for performance of the hanger / restrainer function.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Eaton 103 B-Line series Pipe Hangers & Supports
0 9111111 om
Fig. 28 - "Stand -Off" Hanger & Restrainer for
CPVC Plastic Pipe
Size Range — 3/4" through 2"
Material — Carbon Steel, Pre -Galvanized
Function — Designed to be used as a hanger and restrainer for CPVC piping where
the "stand-off" design will ease installation by eliminating the need for wood blocking.
Features:
• Flared edge design protects CPVC pipe from any rough or abrasive surfaces.
• Unique twist and lock design holds pipe firmly in place and allows retrofit type
of installation.
• The "Stand-Off'I design eliminates the need for wood block extension.
• Can be installed on horizontal or vertical piping regardless of mounting
surface orientation.
• Attaches easily to wood structure with two hex head self -threading screws
furnished with product.
• Installs easily using rechargeable electrical driver with 5/16" extension socket
eliminating impact tool damage to pipe.
• Attaches easily to steel, minimum 18 gauge with (2) 1/4" x 1'I tek type self drilling
tapping screws.
• UL Listed as a hanger and a restrainer for fire sprinkler piping.
Approvals — Underwriters' Laboratory Listed in the USA (UL) and Canada (cUL) to
support automatic fire sprinkler systems. May be installed into wood using fasteners
supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1 " tek type
screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satis-
fies the UL vertical restraint requirement where needed. UL Listed as a hanger and ver-
tical restraint when installed on 3/8" composite wood material. Use two Fig. 27B Speed
Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper
installed screw when used as a hanger only.
Order by — Figure number and pipe size.
Pat. # 7,455,268, Pat. # 7,832,248
FI G.27B
(1) REQUIRED
HIGH SIDE
OFHANGER
(2)
HANGER APPLICATION HANGER R RESTRAINT
APPLICATION
FIG.2B
FIG.28
FIG. FIG.28
FG�
C &US LISTED
Dimensions • Weights
Pipe
Approx.
Size
A
B
C
Wt.
3/4
31/32
2
31/2
.180
1
35/16
23/1 6
31/2
.210
11/4
35/8
23/8
31/2
.225
11/2
4
21/2
31/2
.310
2
41/2
211/16
35/8
.340
OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 m
CUSTOMER SERVICE • 800.786.5266
www.tolco.com
IC
Residential Connection Char a Estimate
t�ec
August 12, 2020
Customer Name:
Raul Padron
Phone No.
(760) 409-7376
Parcel No.
774-055-021
Geo.
06-06-12-4
Address:
53225 Eisenhower Dr., La Quinta
LID:
687050
Block No.
Lot No.
11 Size of Lot:
4,792
sq. ft.
Tract No.
Type of Service:
R-1: Duplex: El
Triplex:
❑
Apts: ❑
SWSC:
$
1,343.98 Acres:
0.11
SWSC: $12,218.00 /acre
WSBFC:
$
3,707.00
SCC:
$
4,851.00
Treatment:
$2,436/edu
Collection: $2,415/edu
Meter:
$
- Meter Size:
3/4
inch
Meter surcharge:
$
- Service Size:
1
inch
Service:
$
-
Meter & Service: $ 3,600.00
Backflow: $ -
Other: $ -
Sewer Lateral: $ -
Total: $ 13,501.98
Santa Carmelita, part of Capital Improvement program, service
is there but requires to be paid for. Per dwg 16575 a 1" Service
extists & per dwg 15175 a sewer lateral exists. PZ 20-11288
Technician:Sara Lopez
Fees Approved by:
Date: . �a
Information Supplied By Customer
CVWD System Data
Domestic Water Demand*
Service Connection**
Max. Flow= 5 gprn
Max. Flow*= 21 Rpm
Min. Pressure= 20 psi
Inlet Pressure 1= 98.70 psi
Fire Sprinkler Demand*
Outlet Pressure= 78.60 psi
Max. Flow= 21 gprn
Min. Pressure= 23.1 psi
Meter Size = 3/4 inch
System Type: 711
Service Size= 1 inch
Multi Stand Alone
1 Prior to Pressure Regulating Valve
** For Calculation Purposes- Service Connection Includes:
* CVWD USES WORST CASE CONDITION
---� service Connection Pipe=C, Meter Stop, Meter, Check Valve & Shut Off Valve
Calculations: O O! q�� 3/4 " METER 1 " SERVICE
O
Pz= Middle La Quinta �� �.P Q� 2 = 98.70 > 60 psi
HGL= 350 t? meter= 7.84
RES.#= 6631 1 Lu n valves etc.= 12.26
Cr No. C 72298
RES./HT= 32 is *P = 78.60 > 23.1 psi
ax.flow 21.00 GPM
PROP. ELEV.= 138 tnJgT C1V1L
�\Q
Ps is oK 'L� OF CALNV OK to provide service
TRY: Fire Sprinkler Demand Appoved by: — Date: $ /3 16
The meter sizing is for plan check purposes only. The ultimate responsibility resides with the En er-of-Record for the project.
CAL FIRE - RIVERSIDE UNIT
RIVERSIDE COUNTY FIRE DEPARTMENT
OFFICE OF THE FIRE MARSHAL — LA QUINTA CALIFORNIA
78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074
• www.rvcfire.org
August 31, 2020
JC FIRE PROTECTION
81705 De Oro Avenue
Indio, CA 92201
Re: Residential Fire Sprinkler Plan Review — S&R DEVELOPMENT
FSS2020-0110 / 53225 EISENHOWER DRIVE, LA QUINTA, CA 92253
The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County
Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions.
Permanently marked identification signs shall be attached to all control valves.
The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff:
(a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal
operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the
potential to contact CPVC piping once insulation is installed.
(b) Final inspection
The Fire Department approved plans and conditions letter must be at the job site.
Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for
inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131.
All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal
staff at (760)777-7074.
Kohl Hetrick - Fire Safety Specialist
It
it
RIVERSIDE COUNTY FIRE PROTECTION PLANNING 0
RECORD OF INSPECTIONS / PERMIT CARD
CVGICt/
THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. - cALLroRMA -
INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE.
JOB
ADDRESS:
53225 EISENHOWER DR
PERMIT#:
FSS2020-0110
DATE ISSUED:
8/31/2020
DESCRIPTION:
S&R DEVELOPMENT — RES SPK
CONTRACTOR:
JC FIRE PROTECTION
HYDRANT SYSTEM
DATE
INITIALS
SPECIAL SUPPRESSION
DATE
INITIALS
Thrust block pre -pour
Door fan test
UG rough piping
Abort test
UG hydro
Mechanical shutdown
Flush
Detector test
Final EF
Deluge/pre-action
SPRINKLER U.G.
Final EF
Thrust block pre -pour
UST/AST TANK
UG rough piping
Installation
UG hydro
Removal
Flush
Emergency shut off
Final EF
Primary piping
FIRE SPRINKLER
Secondary piping
Weld inspection
Dispensers & shear valves
Overhead rough piping
Final EF
Overhead hydro
MISC. INSPECTIONS
UG flush / OK to connect
Spray booths
Main drain/inspectors' test
Hood/duct extinguishing
High pile storage
High pile rack storage
In -rack sprinklers
H.P. vents/access/corridors
Hose racks
Tract access/hydrant verification
Final EF
Access & Address verification
HOOD EXTINGUISHING
OTHER CONST. PERMIT
Detection system
Function test
Gas/electrical shut-off
Nozzle model/placement
Fire alarm connection
Final E F
SPRAY BOOTHS
FIRE CODE PERMIT(S)
Installation
Air flow test
Mechanical interlock
Extinguishing system
Fire alarm connection
Final EF
FIRE ALARM
KNOX SYSTEM
Rough -wire inspection
Building Knox box
Function test
Gate access Knox box/padlock
Duct detectors/velocity
BUILDING INSPECTIONS
24 hr. battery test
T/I final
Sprinkler monitoring
Shell final
Final EF
Final for occupancy
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
FINAL INSPECTION DATE: INSPECTORS SIGNATURE:
**WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE**
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
INSPECTION NOTES
1. Sway bracing and hangers will be inspected at the time of rough piping inspection.
2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler
Systems)
3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required.
4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test.
5. Contractor shall supply all testing equipment, access and operating instructions at time of test.
6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the
affected system to be covered or hidden.
POLICIES ON FIELD INSPECTIONS
A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when
scheduling inspectionr-. For City of La Quinta inspections call: (760) 777-7131.
B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence
without approved plans.
C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required
to schedule the necessary inspections and be present on site for inspections.
D. RE -INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not
on site or where previously noted corrections have not been completed.
E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into
the structure until clearance has been granted by the Fire Dept and Building Official.
F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance
has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official.
INSPECTION NOTES:
THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE
AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS.
THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180
DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE.
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE
REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131