Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FSS2020-0112
Description: STEMMER RESIDENCE Type: FIRE SPRINKLER (WEB) Subtype: RESIDENTIAL - CUSTOM Status: FINALED Applied: 9/4/2020 ECON HOMES Approved: 9/21/2020 KHET Parcel No: 773314027 Site Address: 52975 AVENIDA OBREGON ,CA Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 172 Lot: 12 Issued: 12/21/2020 ONLINE UNIT 17 Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 4/12/2021 KHET Valuation: $4,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 112 \0 17 91 100 Applied to Approved Approved to Issued Issued to Finaled ADDITIONAL IN NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 (760)625-5908 JCFIREPROTECTION @V ERIZON.NET CONTRACTOR J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 (760)625-5908 JCFIREPROTECTION @V ERIZON.NET OWNER JOE W STEMMER JR. CONSTRUCTION 52975 AVENIDA OBREGON LA QUINTA CA 92253 (760)625-5908 Printed: Wednesday, February 22, 2023 4:42:52 PM 1 of 4 WSYSiEMS CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY FIRE FAILED OR ADDITIONAL RE- 101-0000-42421 0 $161.00 $161.00 4/12/21 WEB7875 082994 CREDIT J C FIRE PROTECTION ECON INSPECTION FIRE SPRINKLER SYSTEMS - SINGLE 101-0000-42421 0 $161.00 $161.00 12/21/20 WEB7006 084432 CREDIT J C FIRE PROTECTION ECON FAMILY DETACHED FIRE SPRINKLER SYSTEMS - SINGLE 101-0000-42420 0 $242.00 $242.00 12/21/20 WEB7006 084432 CREDIT J C FIRE PROTECTION ECON FAMILY DETACHED PC Total Paid for FIRE FEES: $564.00 $564.00 RECORDS 101-0000-42416 0 $10.00 $10.00 12/21/20 WEB7006 084432 CREDIT J C FIRE PROTECTION ECON MANAGEMENT FEE Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY 502-0000-43611 0 $5.00 $5.00 12/21/20 WEB7006 084432 CREDIT J C FIRE PROTECTION ECON ENHANCEMENT FEE Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:•0 $579.00 SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES DATE DATE OVERHEAD ROUGH KHET 12/21/2020 12/21/2020 APPROVED REMOTE VIDEO PIPING INSPECTION OVERHEAD HYRO KHET 12/21/2020 12/21/2020 APPROVED REMOTE VIDEO INSPECTION PROVIDE MINIMUM CLEARANCE TO HVAC FIRE FINAL** KHET 3/4/2021 3/4/2021 DISAPPROVE SEE NOTES DIFFUSER. *RESIDENCE WAS ALSO NOT D READY FOR "FINAL FOR OCCUPANCY" FIRE FINAL** KHET 4/12/2021 4/12/2021 APPROVED Printed: Wednesday, February 22, 2023 4:42:52 PM 2 of 4 WSYSiEMS PARENT PROJECTS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK) KOHL HETRICK 9/4/2020 9/21/2020 9/21/2020 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH (1 PERMIT TECH 9/4/2020 9/8/2020 9/8/2020 COMPLETE DAY) BUCKET BOND INFORMATION Attachment Type CREATED OWNER ATTACHMENTS DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 9/4/2020 EtrakitContractor 1ST SUBMITTAL AREA 2CALCS AREA 2 2 HEAD.PDF 1 DOC 9/4/2020 EtrakitContractor 1ST SUBMITTAL CPVCPIPE blazemaster.pdf 1 AND FITTINGS DOC 9/4/2020 EtrakitContractor 1ST SUBMITTAL vk 329 Recessed 2.8 k 1 PENDENT SPRINKLER QR.pdf DOC 9/4/2020 EtrakitContractor 1ST SUBMITTAL vk 496 3.Ok Flat 1 CONCEALED SPRINKLER Concealed.pdf DOC 9/4/2020 EtrakitContractor 1ST SUBMITTAL CHECK spears cpvc check valve 1 VALVE page.28.pdf DOC 9/4/2020 EtrakitContractor 1ST SUBMITTAL fig28.pdf 1 HANGER DOC 9/4/2020 EtrakitContractor 1ST SUBMITTAL pc-cpvc-double- 1 HANGER offset.pdf DOC 9/4/2020 EtrakitContractor 1ST SUBMITTAL RCCE RCCE for lot 12 .pdf 1 DOC 9/4/2020 EtrakitContractor 1ST SUBMITTAL PLANS Stemmer Residence Lot 1 12 Fire Sprinklers.pdf DOC 9/4/2020 EtrakitContractor 1ST SUBMITTAL AREA 1 AREA 11 HEAD.PDF 1 CALCS Printed: Wednesday, February 22, 2023 4:42:52 PM 3 of 4 WSYSiEMS ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 12/21/2020 KOHL HETRICK FSS2020-0112 - COA FSS2020-0112 - COA 1 AND JOB CARD.pdf AND JOB CARD.pdf FSS2020-0112- FSS2020-0112- DOC 12/21/2020 KOHL HETRICK APPROVED PLANS AND APPROVED PLANS AND 1 CALCS.pdf CALCS.pdf DOC 12/21/2020 KOHL HETRICK 12-21-2020 INSPECTION 12-21-2020 INSPECTION 1 NOTES. pdf NOTES.pdf Printed: Wednesday, February 22, 2023 4:42:52 PM 4 of 4 WSYSiEMS oa..a TYPICAL HANGER DETAILS a�w, SUPPORT SPACING AT SPRINKLERS SPRINKLER SPACING INSTALLATION NOTES oTM� ro — o.naE—Nuo�. o��eme�LL ��xEmeaame�Axx CVWD SYSTEM DATA DATE OBSERVED = 04-08-2020 INLET PRESSURE = 99.5 OUTLET PRESSURE = 79.4 ADJUSTED OUTLET PRESSURE = 71.4 mnsxx mma t" RISER DETAIL CROSS SECTION A. 3na-,-a AREA 2 I., AREA 1 pAll� °� II16®� liil E�1� —G1 �.7 ill l�ti1l 1 _w_ !'� ►'_d V iSi�m ��i /P� O I' , r � 0 FO }0 0-0 D O I uc la-� AREA AREA W 41 .®me,axEa i� FIRE aSPRINKLERNINIPINPINGpPLAN na-, D GENERAL FIRE SPRINKLER NOTES FIRE PHU I EG I ION SYMBOLS $,]/jKL DESCR PTON ge oamlc vor o,r vurc x/ I. .� �xar. � n,aaw�o aa,L.,n..oa ca�� xolan I o,.a " sows f NFPA13D A. LIARS. -1 AND DIF 111 IAI IEDWDIS INGNAIED A—D D D HIT 1111 Na 3 D INI °"a3 LI-1_ NFPA,3D AHJ USE ONLY APPROVED Riverside County Fire Department Le Quints Office of the Fire Marshal BY: Kohl Hetri4'� U^ FIRE SAFETY SPECIALIST 0921=D 9:24:11 AM TM1e eppoval of plans end speolflcations does not in- t. n violation, deletion, omission or faulty atoll of airy re9ulrementa of TBIe 24 eery Local - Ordinances. Construction sM1all remain,n untixpiae and exposed ro, impenion pa,poaea l apa and ma Fire Depanmam. PERMIT#- FSS2020-0112 /A�6t Residential Connection Charge Estimate_ a�s7: April 8, 2020 Customer Name Joe Stemmer Phone No. (760) 880-3525 Parcel No. 773-314-027 Geo. 06-06-12-2 Address: 52975 Avenida Dhregon, La Quinta LID: 685178 Block No. Lot No. 11 & 12 51ze of Lot: ''' Sq. ft. Tract No. 35243•I J Type of Service: Yp R-1: Duplex I Triplex: Apts: SWSC; WSBFC: Scc: 4,851.00 Meter: $ - Meter surcharge: $ Service: $ - Acres: 0.2 SWSC* $0.00 /acre Treatment: Meter Size: 3/4 Service Size-. 52,436/edu Collection: $2,415fedu inch inch Meter & Service: $ REQUIRES LANDSCAPE PLANS. Retrofit existing meter. install check valve and upgrade meter box for fire protection, Backflow: $ - Other: $ 300.00 Dwg. 16554 a V srvc exists Dwg- 16596 a 4'' swr lat exists. No record of 5CC been paid, will collect SCC. WSBFC and SWSC Sewer Lateral: $ - satisfied. Per Act# 338961-695178 a 314" existed, No record of Total: $ 5,151.00 when it was paid. PZ 20.10928 Technician: Ruben Montiel Fees Approved by: Date: Information Supplied By Customer ll� CVWD System Data Domestic Water Demand* Service Connection" Max. Flow= 5 9pm Max- Flow*= 21 gpm Min. Pressure= 20 psi Inlet Pressure'= 99.57 p51 Fire Sp inkler Demand` Outlet Pressure= 79.47 psi Max. Flow= 21 8pm Min. Pressure= 23.1 psi MeterSize = 3/4 inch System Type, _ Service 5ize= inch Multi Stand Alone t Prior to Pressure Regulating Valve �* For Calculation Purposes- Service Connection Includes: CVWD USES WORST CASE CONDITION iervi:e � — section Pipe-L', Meter Stop, Meter,Check Valve&5hut Off Valve Calculation,. 3/4 "METER 1 "5ERVICE ESS/0 Pi= Middle La Quaki,a 99.57 y 60 psi A FfGL= 350 �� �Q Q� eter= 7.84 RES.N= 6631.1 t„ C ves etc .= 1z.z6 x RE5.7HT= 32 v. M C 58195 �' '1f 79.47 23.1 p5i PROP. ELEV.= 136 �+� ow 21.00 GPM Psis OK 7j, �`lil�L �� K tjp provide servile �0�- TRY: Fire Sprinkler Demand R CJ,�10 AppoVed ay: Vie; The meter sizing is for plan check purposes only. The ultimate responsibility resides wit the Engineer•of-Rec d for the project. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 9/3/2020R RESIDENCE LOT 12 - LA QUINTA - CA - JCP\AREA 2 2 HEAD.SDF JOB TITLE: AREA 2 2HD (12xl2) (8 GPM) WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) M (N/A) 71.4 (N/A) 71.4 21.1 24.8 Available pressure is 46.6 psi (65%) greater than required pressure. AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 21.1 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 16.1 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) Pi 10.0 - - - - 7.7 - - - P2 10.0 K= 3.00 7.1 8.0 P3 10.0 K= 3.00 7.3 8.1 1 10.5 - - - - 7.5 - - - 2 10.5 - - - - 7.0 - - - 3 10.5 - - - - 7.2 - - - A 10.5 - - - - 7.5 - - - A1 10.5 - - - - 7.9 - - - B 10.5 - - - - 7.9 - - - C 12.5 - - - - 7.6 - - - D 12.5 - - - - 7.8 - - - E 9.5 - - - - 11.6 - - - TOR 9.5 - - - - 12.4 - - - FS1 4.0 - - - - 15.1 - - - FS2 4.0 - - - - 18.1 - - - BOR 0.5 - - - - 21.1 - - - DOM 0.5 HOSE STREAM 21.6 5.0 UG -3.0 - - - - 23.8 - - - M -3.0 SOURCE 24.8 21.1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 9/3/2020R RESIDENCE LOT 12 - LA QUINTA - CA - JCP\AREA 2 2 HEAD.SDF JOB TITLE: AREA 2 2HD (12xl2) (8 GPM) PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 0.0 1.101 PL 0.50 PF 0.0 P1 10.0 0.0 7.7 0.0 0.0 150 FTG E PE -0.2 1 10.5 0.0 7.5 0.0 0.000 TL 7.50 PV Pipe: 2 -8.0 1.101 PL 0.50 PF 0.1 P2 10.0 3.0 7.1 8.0 2.7 150 FTG E PE -0.2 2 10.5 0.0 7.0 0.0 0.012 TL 7.50 PV Pipe: 3 -8.1 1.101 PL 0.50 PF 0.1 P3 10.0 3.0 7.3 8.1 2.7 150 FTG T PE -0.2 3 10.5 0.0 7.2 0.0 0.013 TL 6.50 PV Pipe: 4 0.0 1.101 PL 7.75 PF 0.0 1 10.5 0.0 7.5 0.0 0.0 150 FTG ET PE 0.0 A 10.5 0.0 7.5 0.0 0.000 TL 20.75 PV Pipe: 5 -8.0 1.101 PL 9.50 PF 0.2 2 10.5 0.0 7.0 0.0 2.7 150 FTG TR PE 0.0 3 10.5 0.0 7.2 0.0 0.012 TL 17.20 PV Pipe: 6 -16.1 1.101 PL 0.50 PF 0.3 3 10.5 0.0 7.2 0.0 5.4 150 FTG T PE 0.0 A 10.5 0.0 7.5 0.0 0.046 TL 6.50 PV Pipe: 8 -8.0 1.101 PL 19.00 PF 0.4 A 10.5 0.0 7.5 0.0 2.7 150 FTG T2R PE 0.0 B 10.5 0.0 7.9 0.0 0.012 TL 28.40 PV Pipe: 9 -8.0 1.101 PL 22.75 PF 0.6 B 10.5 0.0 7.9 0.0 2.7 150 FTG 2E2TR PE -0.9 C 12.5 0.0 7.6 0.0 0.012 TL 50.45 PV Pipe: 7A -8.0 1.101 PL 12.00 PF 0.2 C 12.5 0.0 7.6 0.0 2.7 150 FTG T PE 0.0 D 12.5 0.0 7.8 0.0 0.012 TL 18.00 PV Pipe: 8A -8.1 1.101 PL 20.75 PF 0.4 A 10.5 0.0 7.5 0.0 2.7 150 FTG T2R PE 0.0 Al 10.5 0.0 7.9 0.0 0.013 TL 30.15 PV Pipe: 9A -8.1 1.101 PL 33.00 PF 0.8 Al 10.5 0.0 7.9 0.0 2.7 150 FTG 2ET6R PE -0.9 D 12.5 0.0 7.8 0.0 0.013 TL 63.20 PV Pipe: 10 -16.1 1.101 PL 28.25 PF 2.5 D 12.5 0.0 7.8 0.0 5.4 150 FTG 3E3R PE 1.3 E 9.5 0.0 11.6 0.0 0.046 TL 54.35 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 9/3/2020R RESIDENCE LOT 12 - LA QUINTA - CA - JCP\AREA 2 2 HEAD.SDF JOB TITLE: AREA 2 2HD (12xl2) (8 GPM) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 22 -16.1 1.101 PL 10.25 PF 0.8 E 9.5 0.0 11.6 0.0 5.4 150 FTG E PE 0.0 TOR 9.5 0.0 12.4 0.0 0.046 TL 17.25 PV Pipe: 23 -16.1 1.101 PL 5.50 PF 0.3 TOR 9.5 0.0 12.4 0.0 5.4 150 FTG R PE 2.4 FS1 4.0 0.0 15.1 0.0 0.046 TL 7.20 PV Pipe: 24 FIXED PRESSURE LOSS DEVICE FS2 4.0 0.0 18.1 0.0 3.0 psi, 16.1 gpm FS1 4.0 0.0 15.1 0.0 Pipe: 25 -16.1 1.101 PL 4.50 PF 1.4 FS2 4.0 0.0 18.1 0.0 5.4 150 FTG 27.0 PE 1.5 BOR 0.5 0.0 21.1 0.0 0.046 TL 31.50 PV Pipe: 26 -16.1 1.055 PL 2.00 PF 0.6 BOR 0.5 0.0 21.1 0.0 5.9 150 FTG T PE 0.0 DOM 0.5 H.S. 21.6 5.0 0.056 TL 10.00 PV Pipe: 27 -21.1 1.055 PL 3.50 PF 0.7 DOM 0.5 H.S. 21.6 5.0 7.8 150 FTG EG PE 1.5 UG -3.0 0.0 23.8 0.0 0.093 TL 7.50 PV Pipe: 29 -21.1 1.394 PL 34.00 PF 1.0 UG -3.0 0.0 23.8 0.0 4.4 150 FTG E PE 0.0 M -3.0 SRCE 24.8 (N/A) 0.024 TL 42.00 PV NOTES (HASS): (1) Calculations were performed by the HASS 2020 D computer program in accordance with NFPA13 (2016) under license no. 64622225 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.003 gpm and a maximum imbalance at any node of 0.062 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 7.8 ft/sec at pipe 27. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node M under full flow conditions is SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 9/3/2020R RESIDENCE LOT 12 - LA QUINTA - CA - JCP\AREA 2 2 HEAD.SDF JOB TITLE: AREA 2 2HD (12xl2) (8 GPM) 71.40 psi with a flow of 38.01 gpm. (6) PIPE FITTINGS TABLE HASS Pipe Table Name: standard.pip PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) F E T R K C G F45 Ell Tee RunT Kplg ChkVly Gate 1.101 1.40 7.00 6.00 1.70 1.00 8.00 0.40 1.394 1.80 8.00 7.30 2.30 1.00 11.00 0.80 PAGE: M MATERIAL: CT-M HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Ell Tee 45-Ell TeeRun Kouplg ChkVly GatVly NPTee 1.055 3.00 8.00 2.00 3.00 0.00 8.00 0.00 8.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 9/3/2020R RESIDENCE LOT 12 - LA QUINTA - CA - JCP\AREA 2 2 HEAD.SDF JOB TITLE: AREA 2 2HD (12xl2) (8 GPM) WATER SUPPLY ANALYSIS Fixed Source Pressure: 71.40 psi SI 1 7010 60.0 G A U G 50.0 E P 40.0 R E S 30.0 S U 2 R E 20.0 p 10.0 s i 0.0 -14.7 LEGEND 1 j Available pressure 71.40 psi @ 21.1 gpm 2 l Required pressure 24.85 psi @ 21.1 gpm A. Source Supply Curve B. System Demand Curve 600900 1200 1500 1800 2100 2400 2700 3000 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 9/3/2020R RESIDENCE LOT 12 - LA QUINTA - CA - JCP\AREA 2 2 HEAD.SDF JOB TITLE: AREA 2 2HD (12x12) (8 GPM) WATER SUPPLY CURVE I I I 66+ I I I 60+ I I I 54+ I I I P 48+ R E S S 42+ U R E 36+ ( I P S I 30+ I I x 24+ I I I 18+ I I 12+ LEGEND " I" X = Required Water Supply " 24.85 psi @ 21.1 gpm " 6+ " 0 = Available Water Supply " I" 71.40 psi @ 21.1 gpm " 0++-+---+----+-----+------+--------+--------+---------+-----------+ 8001200 1600 2000 2400 2800 3200 3600 4000 FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 9/3/2020R RESIDENCE LOT 12 - LA QUINTA - CA - JCP\AREA 1 1 HEAD.SDF JOB TITLE: AREA 1 1HD (14xl4) (12 GPM) WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) M (N/A) 71.4 (N/A) 71.4 17.0 30.5 Available pressure is 40.9 psi (57%) greater than required pressure. AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 17.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 12.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) Pi 10.0 K= 3.00 16.0 12.0 P2 10.0 - - - - 16.8 - - - P3 10.0 - - - - 16.8 - - - 1 10.5 - - - - 16.0 - - - 2 10.5 - - - - 16.5 - - - 3 10.5 - - - - 16.5 - - - A 10.5 - - - - 16.5 - - - A1 10.5 - - - - 16.8 - - - B 10.5 - - - - 16.7 - - - C 12.5 - - - - 16.2 - - - D 12.5 - - - - 16.4 - - - E 9.5 - - - - 19.1 - - - TOR 9.5 - - - - 19.6 - - - FS1 4.0 - - - - 22.1 - - - FS2 4.0 - - - - 25.1 - - - BOR 0.5 - - - - 27.5 - - - DOM 0.5 HOSE STREAM 27.8 5.0 UG -3.0 - - - - 29.8 - - - M -3.0 SOURCE 30.5 17.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 9/3/2020R RESIDENCE LOT 12 - LA QUINTA - CA - JCP\AREA 1 1 HEAD.SDF JOB TITLE: AREA 1 1HD (14xl4) (12 GPM) PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -12.0 1.101 PL 0.50 PF 0.2 P1 10.0 3.0 16.0 12.0 4.0 150 FTG E PE -0.2 1 10.5 0.0 16.0 0.0 0.026 TL 7.50 PV Pipe: 2 0.0 1.101 PL 0.50 PF 0.0 P2 10.0 0.0 16.8 0.0 0.0 150 FTG E PE -0.2 2 10.5 0.0 16.5 0.0 0.000 TL 7.50 PV Pipe: 3 0.0 1.101 PL 0.50 PF 0.0 P3 10.0 0.0 16.8 0.0 0.0 150 FTG T PE -0.2 3 10.5 0.0 16.5 0.0 0.000 TL 6.50 PV Pipe: 4 -12.0 1.101 PL 7.75 PF 0.5 1 10.5 0.0 16.0 0.0 4.0 150 FTG ET PE 0.0 A 10.5 0.0 16.5 0.0 0.026 TL 20.75 PV Pipe: 5 0.0 1.101 PL 9.50 PF 0.0 2 10.5 0.0 16.5 0.0 0.0 150 FTG TR PE 0.0 3 10.5 0.0 16.5 0.0 0.000 TL 17.20 PV Pipe: 6 0.0 1.101 PL 0.50 PF 0.0 3 10.5 0.0 16.5 0.0 0.0 150 FTG T PE 0.0 A 10.5 0.0 16.5 0.0 0.000 TL 6.50 PV Pipe: 8 -5.9 1.101 PL 19.00 PF 0.2 A 10.5 0.0 16.5 0.0 2.0 150 FTG T2R PE 0.0 B 10.5 0.0 16.7 0.0 0.007 TL 28.40 PV Pipe: 9 -5.9 1.101 PL 22.75 PF 0.4 B 10.5 0.0 16.7 0.0 2.0 150 FTG 2E2TR PE -0.9 C 12.5 0.0 16.2 0.0 0.007 TL 50.45 PV Pipe: 7A -5.9 1.101 PL 12.00 PF 0.1 C 12.5 0.0 16.2 0.0 2.0 150 FTG T PE 0.0 D 12.5 0.0 16.4 0.0 0.007 TL 18.00 PV Pipe: 8A -6.1 1.101 PL 20.75 PF 0.2 A 10.5 0.0 16.5 0.0 2.0 150 FTG T2R PE 0.0 Al 10.5 0.0 16.8 0.0 0.007 TL 30.15 PV Pipe: 9A -6.1 1.101 PL 33.00 PF 0.5 Al 10.5 0.0 16.8 0.0 2.0 150 FTG 2ET6R PE -0.9 D 12.5 0.0 16.4 0.0 0.007 TL 63.20 PV Pipe: 10 -12.0 1.101 PL 28.25 PF 1.4 D 12.5 0.0 16.4 0.0 4.0 150 FTG 3E3R PE 1.3 E 9.5 0.0 19.1 0.0 0.026 TL 54.35 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 9/3/2020R RESIDENCE LOT 12 - LA QUINTA - CA - JCP\AREA 1 1 HEAD.SDF JOB TITLE: AREA 1 1HD (14xl4) (12 GPM) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 22 -12.0 1.101 PL 10.25 PF 0.5 E 9.5 0.0 19.1 0.0 4.0 150 FTG E PE 0.0 TOR 9.5 0.0 19.6 0.0 0.026 TL 17.25 PV Pipe: 23 -12.0 1.101 PL 5.50 PF 0.2 TOR 9.5 0.0 19.6 0.0 4.0 150 FTG R PE 2.4 FS1 4.0 0.0 22.1 0.0 0.026 TL 7.20 PV Pipe: 24 FIXED PRESSURE LOSS DEVICE FS2 4.0 0.0 25.1 0.0 3.0 psi, 12.0 gpm FS1 4.0 0.0 22.1 0.0 Pipe: 25 -12.0 1.101 PL 4.50 PF 0.8 FS2 4.0 0.0 25.1 0.0 4.0 150 FTG 27.0 PE 1.5 BOR 0.5 0.0 27.5 0.0 0.026 TL 31.50 PV Pipe: 26 -12.0 1.055 PL 2.00 PF 0.3 BOR 0.5 0.0 27.5 0.0 4.4 150 FTG T PE 0.0 DOM 0.5 H.S. 27.8 5.0 0.033 TL 10.00 PV Pipe: 27 -17.0 1.055 PL 3.50 PF 0.5 DOM 0.5 H.S. 27.8 5.0 6.2 150 FTG EG PE 1.5 UG -3.0 0.0 29.8 0.0 0.062 TL 7.50 PV Pipe: 29 -17.0 1.394 PL 34.00 PF 0.7 UG -3.0 0.0 29.8 0.0 3.6 150 FTG E PE 0.0 M -3.0 SRCE 30.5 (N/A) 0.016 TL 42.00 PV NOTES (HASS): (1) Calculations were performed by the HASS 2020 D computer program in accordance with NFPA13 (2016) under license no. 64622225 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.010 gpm and a maximum imbalance at any node of 0.173 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 6.2 ft/sec at pipe 27. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node M under full flow conditions is SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 9/3/2020R RESIDENCE LOT 12 - LA QUINTA - CA - JCP\AREA 1 1 HEAD.SDF JOB TITLE: AREA 1 1HD (14xl4) (12 GPM) 71.40 psi with a flow of 25.68 gpm. (6) PIPE FITTINGS TABLE HASS Pipe Table Name: standard.pip PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) F E T R K C G F45 Ell Tee RunT Kplg ChkVly Gate 1.101 1.40 7.00 6.00 1.70 1.00 8.00 0.40 1.394 1.80 8.00 7.30 2.30 1.00 11.00 0.80 PAGE: M MATERIAL: CT-M HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Ell Tee 45-Ell TeeRun Kouplg ChkVly GatVly NPTee 1.055 3.00 8.00 2.00 3.00 0.00 8.00 0.00 8.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 9/3/2020R RESIDENCE LOT 12 - LA QUINTA - CA - JCP\AREA 1 1 HEAD.SDF JOB TITLE: AREA 1 1HD (14xl4) (12 GPM) WATER SUPPLY ANALYSIS Fixed Source Pressure: 71.40 psi 80.0 7010 60.0 G A U G 50.0 E P 40.0 R E S 3020 S U R E 20.0 p s i 10.0 we] -14.7 LEGEND 1 j Available pressure 71.40 psi @ 17.0 gpm 2 l Required pressure 30.46 psi @ 17.0 gpm A. Source Supply Curve B. System Demand Curve 600900 1200 1500 1800 2100 2400 2700 3000 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 9/3/2020R RESIDENCE LOT 12 - LA QUINTA - CA - JCP\AREA 1 1 HEAD.SDF JOB TITLE: AREA 1 1HD (14x14) (12 GPM) WATER SUPPLY CURVE I I I 66+ I I I 60+ I I I 54+ I I I P 48+ R E S S 42+ U R E 36+ ( I P S I 30X I I I 24+ I I I 18+ I I 12+ LEGEND " I" X = Required Water Supply " 30.46 psi @ 17.0 gpm " 6+ " 0 = Available Water Supply " I" 71.40 psi @ 17.0 gpm " 0++-+---+----+-----+------+--------+--------+---------+-----------+ 8001200 1600 2000 2400 2800 3200 3600 4000 FLOW (GPM) Page 1 of 5 FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Viking Freedom") Residential Concealed Pendent Sprinkler VK496 is a small thermosensitive, glass -bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 3.0 (43.2 metric*), allows the sprinkler's efficient use of available water supplies for the hydraulically designed fire -protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre -assembled with a threaded adapter for installation with a low -profile small -diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push -on", "thread -off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2" (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL- US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS c& UL Listed (C-UL-US-EU): Category VKKW eu Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 3.0 U.S. (43.2 metric*) Glass -bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C31600 Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-051000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic Available Finishes and Temperature Ratings: Finish Brass ENT Suffix A JN Temperature 155 *F (68 *C) 200*F (93 *C) Suffix B E Ordering Information: Refer to Tables 1 and 2. WARNING: Cancer and Reproductive Harm- www. P65Warni ngs.ca.gov Form No. F_032218 19.03.21 Rev 19.1 New page. Page 2 of 5 FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat -sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pressure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK496 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: ORDERING Instructions: Using the •R• sprinkler base part number, .. the suffix the suffix for Order a cover for the desired.. the desired Temperature Rating. plate Size 1: Finishes 2: Temperature Ratings Sprinkler Description Suffix, Nominal Rating Bulb Color Max. Ambient Ceiling Suffix Base Part NPT BSPT No. Inch mm Temperature 22773 1/2 -- Brass A 155 °F (68 °C) Red 100 °F (38 °C) B ENT 3,4 JN 200 °F (93 °C) Green 150 °F (65 °C) E Example: 22773AE = 200 °F (93 °C) Temperature Rated Sprinkler with a standard Brass finish. Accessories Sprinkler Wrenches (see Figure 1): A. Heavy Duty Part Number: 14047WB5 B. Head Cabinet Wrench Part Number: 140311 Sprinkler Cabinet: Part number 01731A. Footnotes I Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. z. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. LIL Listed as corrosion resistant. 4. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. 5. Requires a 1/2" ratchet which is not available from us. 6. Optional for removal of the protective cap. Ideal for sprinkler cabinets. Form No. F_032218 19.03.21 Rev 19.1 Page 3 of 5 FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com COVERTABLE 2: ORDERING INFORMATION Instructions: Using the cover plate base part number, .. the suffix for the desired Finish .. the suffix for the required Cover Plate Nominal Rating. 1: Finishes Temperature Rating Matrix' z Cover Plate Size Cover Plate Sprinkler Sprinkler Max. Base Part Style Inch (mm) Number Description Suffixs N urinal Nominal Rating AmbienTemper Suffix (Required) tubing 13504 2-3/4 (70) Round Polished Chrome F 135 °F (57 °C) 155 °F (68 °C) 100 °F (38 °C) A 13642 3-5/16 (84) Round Brushed Chrome F-/B 165 °F (73 °C)3 200 °F (93 °C) 150 °F (65 °C) C 15394 3-5/16 (84) Square Bright Brass B Corrosion Resistant Sprinkler Coating: ENT Antique Brass B-/A Brushed Brass B-/B Brushed Copper E-/B Example: 13504MA/W = Painted White M-/W 135 °F (57 °C) Temperature Rated 2-3/4" (70 mm) Diameter Round Cover Plate with a Painted White finish. Painted Ivory MA Painted Black M-/B Footnotes 1 The sprinkler temperature rating is stamped on the deflector. s. Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. Maximum ambient temperature for cover assembly is 100 °F (38 °C). 4. Part number shown is the base part number. For complete part number, refer to current our price list schedule. 5. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. 6. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. Form No. F_032218 19.03.21 Rev 19.1 Page 4 of 5 FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com APPROVAL CHART VK496, 3.0 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D Sprinkler Base Thread Size Nominal K-Factor Part Number I SIN Maximum Water Working Pressure Inches mm U.S. metric z 22773 VK496 1/2 15 3.0 43.2 175 psi (12 bar) Maximum Listings and Coverage Area 5 All Temperatures Deflector A rovals3 pp Minimum Spacing W X L to Ceiling Installation Type Ft. Flow Pressure Ft. X Ft. (m) (m X m) gpm (Lpm) PSI (bar) C@LF84 Eu 12 X 12 8 7.1 (3.7 X 3.7) (30.3) (0.49) Refer to Concealed with Cover See Footnotes 3, 4, and 8 8 14 X 14 12 16 (4.3 X 4.3) (45.4) (1.1) Figure 2 Plate Assembly. See Footnotes 6 & 7. (2.4 ) 16 X 16 15 25 (4.9 X 4.9) (56.8) (1.72) Footnotes I. Part number shown is the base part number. For complete part number, refer to current our price schedule. Y. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. I This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approv- als. Refer also to Design Criteria. a Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union. 5. For areas of coverage smaller than shown, use the "Flow' and "Pressure" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow" and "Pressure' used. 5. Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 7 Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 6. s. C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) Form No. F_032218 19.03.21 Rev 19.1 Page 5 of 5 FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) UL Listing Reguirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK496 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area" in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT. Always refer to Bulletin Form No. F 080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** Sprinkler Wrench - Part No. 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. 2-1/4" (57 mm) diameter opening required in the ceiling. Step 2: 1 1 Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Sprinkler wrench flat Figure 1: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) Sprinkler frame arms Form No. F_032218 19.03.21 Rev 19.1 Page 6 of 5 FREEDOM° RESIDENTIAL A A A CONCEALED PENDENT SPRINKLER VK496 (K3.0) -N41K] The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1/2" (15 mm) NPT E C4 Co N 2-9/16" (65 mm) Maximum %"— NOTE: Upon sprinkler activation, the deflector descends to approximately 13116" (21 mm) below the sprinkler body. 2-1/16" (52 mm) Minimum Figure 2: Sprinkler Dimensions and Cover Installation All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 3: Identification of Custom Paint for Concealed Covers - — V 2-3/4" (70 mm) or 3-5/16" (84 mm) Figure 4: Square Cover Assembly 15394 Form No. F_032218 19.03.21 Rev 19.1 New page. Page 1 of 6 MICROFAST° QUICK RESPONSE PENDENT SPRINKLER VK329 (K2.8) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK329 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Polytetrafluoroethelyne (PTFE) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global has no approval classification for PTFE and Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS c u� us cULus Listed: Category VNIV aM FM Approved: Class Series 2000 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 2.8 U.S. (40.3 metric**) Glass -bulb fluid temperature rated to -65 °F (-55 °C) Viking Technical Data may be found on Overall Length: 2-1/4" (58 mm) The Viking Corporation's Web site at *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). http://www.vikinggroupinc.com. The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). The Web site may include a more recent Material Standards: I edition of this Technical Data Page. Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C26000 Bushing: Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring -Exposed, Screw -Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring -Exposed Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Upright and Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and Black PTFE = N Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G For example, sprinkler VK329 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12981AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000). B. Wrench for Recessed Pendent Sprinklers: Part No. 16036W/B** (available since 2011) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A'/z' ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Form No. F_061714 16.01.28 Rev 16.1 Replaces form F_061714 Rev. 14.2 (Revised temperature suffix designation) Page 2 of 6 MICROFAST° QUICK RESPONSE PENDENT SPRINKLER VK329 (K2.8) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Sprinkler Cabinets: A. Six -head capacity: Part No. 01724A (available since 1971) B. Twelve -head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat -sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast° Quick Response Pendent Sprinkler VK329 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler Clip %� ift Wrench Flat Protective Sprinkler Cap 10896 • Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_061714 16.01.28 Rev 16.1 Page 3 of 6 MICROFAST° QUICK RESPONSE PENDENT S-N411aPRINKLER VK329 (K2.8) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature z Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and Black PTFE Corrosion -Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. s The corrosion -resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and PTFE coatings. Sprinkler wrench 16036W/B** for recessed pendent sprinklers ** A 1/2" ratchet is required (not available from Viking) Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 16036W/B for Recessed Pendent Sprinklers Form No. F_061714 16.01.28 Rev 16.1 Page 4 of 6 MICROFAST° QUICK RESPONSE PENDENT SPRINKLER VK329 (K2.8) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 1 (UL) Temperature KEY The Viking Microfast® Quick Response of FinishEscut eon [if applicable] Pendent Sprinkler VK329 Maximum 175 PSI (12 Bar) WWP Base Sprinkler p Thread Size Nominal K-Factor Overall Length Listings and Approvals' Part SIN (Refer also to Design Criteria.) Style Number NPT BSP U.S. I metricz Inches I mm cULus° I VdS I LPCB I Cc C 12981 VK329 Pendent 1/2" 15 mm 2.8 40.3 2-1/4 58 A1Z, 61Y -- NOTICE Office) 06718E VK329 Pendent 1/2" 15 mm 2.8 40.3 2-3/16 56 A1Z, B1Y -- Approved Escutcheons Approved Temperature Ratings Approved Finishes Y - Standard surface -mounted escutcheon or the A- 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 Viking Microfast® Model F-1 Adjustable Escutcheon, or °C), 200 °F (93 °C), 286 °F (141 °C) 1 - BrassChrome, Whit recessed with the Viking Micromatic® Model E-1, E-2, or B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 6 Polyester Black Polyester E3 Recessed Escutcheon °C), and 200 °F (93 °C) and Black PTFE Z - Standard surface -mounted escutcheon or the Viking Microfast® Model F-1 Adjustable Escutcheon Footnotes t Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. ° Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 6 cULus Listed as corrosion -resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast° Quick Response Pendent Sprinkler VK329 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT. Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_061714 16.01.28 Rev 16.1 Page 5 of 6 MICROFAST° QUICK RESPONSE PENDENT SPRINKLER VK329 (K2.8) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 (FM) Temperature KEY The Viking Microfast® Quick Response ■f— Finish AI X-0 Escutcheon (if applicable] Pendent Sprinkler VK329 Maximum 175 PSI (12 Bar) WWP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' Number' SIN Style (Refer also to Design Criteria.) NPT BSP U.S. metric2 Inches mm 12981 VK329 Pendent 112" 15 mm 2.8 40.3 2-1/4 1 58 A1Z NOTICE.. Office) 16718B VK329 I Pendent 1 112" 15 mm 2.8 F 40.3 2-3/16 1 56 A1Z Approved Temperature Ratings Approved Finishes Approved Escutcheons A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F 1 - Brass and Chrome Z - Standard surface -mounted escutcheon or the (93 °C), 286 °F (141 °C) Viking Microfast® Model F-1 Adjustable Escutcheon Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. s This table shows the FM Approvals available at the time of printing. Other approvals may be in process. ^ Other colors are available on request with the same Approvals as the standard colors. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Reauirements: The Viking Microfast® Quick Response Pendent Sprinkler VK329 is FM Approved as quick response Non -storage upright and pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT. Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_061714 16.01.28 Rev 16.1 Page 6 of 6 ' MICROFAST° QUICK RESPONSE PENDENT SPRINKLER VK329 (K2.8) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1/2" (15 NPT` 2-1/4" 1-3/4" (57 mm) (44.5_ m m Installed with a standard 1/8" surface -mounted escutcheon Ceiling Opening Size: 2-516/" (58.7 mm) minimum 2-1/2" (63.5 mm) maximum 2-1/8" (54 mm) 1-1/2 2" (38 mm) (51 mm) Min. Max. Installed with a Microfast Note: At maximum, adapter is Model F-1 Adjustable exposed 1/2" (12.7 mm) from Escutcheon face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon 2-1/8" (54 mm) INA 1 3/4" (28.6 mm) (44.5 mm) -- Min. Max. Installed with a Model E-1 Recessed Escutcheon Ceiling Opening Size: 2-516/" (58.7 mm) minimum 2-1/2" (63.5 mm) maximum 2-1 /8" (54 mm) f 1-1/8" 2"" (28.6 mm) (51 mm) - Min. Max. —ftm Installed with a Model E-2 Thread -on Recessed Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_061714 16.01.28 Rev 16.1 Replaces form F_061714 Rev. 14.2 (Revised temperature suffix designation) t&ICU Fire & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 BlazeMaster ° CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description Tyco Fire & Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings are designed exclusively for use in wet pipe automatic fire sprinkler systems. They are made from a specially devel- oped thermoplastic compound com- posed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TFBP BlazeMaster CPVC products are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as com- pared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapters are available to connect CPVC pipe to metallic pip- ing. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. WARNING Tyco Fire & Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Da to Sizes 3/4" to 3" Maximum Working Pressure 175 psi Approvals UL, FM, CUL, NSF, Dade County, LPCB, MEA, and the City of Los Ange- les. (Refer to IH-1900, Rev. 0, Janu- ary 2005 "Installation Instruction & Technical Handbook" for exact list- ing/approval information.) Manufacture Source U.S.A. Material ❑ Pipe: ASTM F442, SDR 13.5 ❑ Fittings: ASTM F438 (Sch. 40) and ASTM F439 (Sch. 80), ASTM F1970 Color Orange Aft rapid response'" HOME FIRE SPRINKLER SYSTEM BlazeMasteO) is a registered trademark of Noveon IP Holding Corp. Page 1 of 6 JANUARY, 2006 TFP1915 Page 2 of 6 TFP1915 WATER NOMINAL AVERAGE AVERAGE WEIGHT FILLED WEIGHT FT. OF PIPE WEIGHT PER LIFT SIZE O.D. I.D. Ibs./ft. Ibs./ft. PER LIFT Ibs. 3/4" 1.050" 0.874" 0.18 0.44 7875 1339 1" 1.315" 1.101, 0.26 0.67 5040 1320 1-1/4" 1.660" 1.394" 0.42 1.08 2835 1191 1-1/2" 1.9001, 1.598" 0.54 1.41 2205 1213 2" 2.375" 2.003" 0.84 2.20 1260 1084 2-1/2" 2.875" 2.423" 1.26 3.26 1215 1531 3" 3.500" 2.952" 1.87 4.83 720 1344 Installation Tyco Fire and Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings are to be installed in accord- ance with IH-1900, Rev. 0, January 2005 "Installation Instruction & Techni- cal Handbook". FIGURE 1 — PIPE DIMENSIONS Care and Maintenance The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or product manufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central sta- tion alarms. TFP1915 Page 3 of 6 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT SCHD. WEIGHT TYPE NUMBER (T/O) (lb.) TEE 80000 3/4" 5/8" 40 0.11 T/O 80001 1" 11/16" 40 0.19 80002 1-1/4" 7/8" 40 0.26 80003 1-1/2" 1-1/16" 80 0.51 80004 2" 1-3/8" 80 0.90 80005 2-1/2" 1-9/16" 80 1.59 T/O T/O 80006 3" 1-13/16" 80 2.41 XxYxZ X Y Z 3/4" x 3/4" x 1" 3/4" 3/4" 5/8" 80132 40 0.14 80133 1" x 3/4" x 3/4" 9/16" 9/16" 3/4" 40 0.14 80134 1" x 3/4" x 1" 3/4" 11/16" 3/4" 40 0.17 80260 1" x 1" x 3/4" 5/8" 5/8" 13/16" 40 0.16 80135 1-1/4" x 1" x 3/4" 5/8" 5/8" 15/16" 40 0.21 80136 1-1/4" x 1" x 1" 3/4" 3/4" 15/16" 40 0.22 80137 1-1/4" x 1" x 1-1/4" 15/16" 15/16" 7/8" 40 0.26 REDUCING TEE 80261 1-1/4" x 1-1/4" x 3/4" 5/8" 5/8" 7/8" 40 0.23 80262 1-1/4" x 1-1/4" x 1" 3/4" 3/4" 7/8" 40 0.26 Z 80138 1-1/4" x 1-1/4" x 1-1/2" 1" 1" 1" 80 0.43 T/O 80140 1-1/2" x 1-1/4" x 3/4" 9/16" 9/16" 1" 80 0.36 80141 1-1/2" x 1-1/4" x 1" 9/16" 9/16" 1-1/16" 80 0.38 80263 80264 1-1/2" x 1-1/2" x 3/4" 1-1/2" x 1-1/2" x 1" 9/16" 9/16" 9/16" 9/16" 1" 1-1/16" 80 80 0.36 0.38 X Y 80275 1-1/2" x 1-1/2" x 1-1/4" 7/8" 7/8" 1" 80 0.45 T/O T/O 80265 2" x 2" x 3/4" 3/4" 3/4" 1-3/8" 80 0.61 80266 2" x 2" x 1" 7/8" 7/8" 1-3/8" 80 0.66 80274 2" x 2" x 1-1/4" 1-1/16" 1-1/16" 1-3/8" 80 0.74 80267 2" x 2" x 1-1/2" 1-1/8" 1-1/8" 1-3/8" 80 0.78 80271 2-1/2" x 2-1/2" x 1" 1-9/16" 1-9/16" 1-9/16" 80 1.43 80272 2-1/2" x 2-1/2" x 1-1/4" 1-9/16" 1-9/16" 1-9/16" 80 1.46 80273 2-1/2" x 2-1/2" x 1-1/2" 1-9/16" 1-9/16" 1-9/16" 80 1.48 80276 2-1/2" x 2-1/2" x 2" 1-9/16" 1-9/16" 1-9/16" 80 1.50 80270 3" x 3" x 1-1/2" 1-13/16" 1-13/16" 1-13/16" 80 2.28 80268 3" x 3" x 2" 1-13/16" 1-13/16" 1-3/4" 80 2.25 80269 3" x 3" x 2-1/2" 1-13/16" 1-13/16" 1-13/16" 80 2.44 CROSS & REDUCING CROSS 80009 3/4" 9/16" 40 0.13 T/O 80010 1" 11/16" 40 0.23 80011 1-1/4" 15/16" 40 0.34 80012 1-1/2" 1-1/16" 80 0.67 80013 2" 1-5/16" 80 1.00 80014 2-1/2" 1-9/16" 80 1.91 T/O 80008 3" 1-13/16" 80 2.89 80015 1" x 1" x 3/4" x 3/4" 7/8" 40 0.28 T/O T/O 80025 3/4" 5/8" 40 0.09 90' ELBOW & REDUCING ELBOW 80026 1" 3/4" 40 0.14 80027 1-1/4" 7/8" 40 0.21 X 80028 1-1/2" 1-1/16" 80 0.40 T/O 80029 2" 1-5/16" 80 0.79 80030 2-1/2" 1-9/16" 80 1.14 Y 80031 3" 1-13/16" 80 1.82 XxY X Y T/O E80032 1" x 3/4" 11116" 13/16" 40 0.16 FIGURE 2 - FITTING DIMENSIONS (Part 1 of 4) Page 4 of 6 TFP1915 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT SCHD. WEIGHT TYPE NUMBER (T/O) (lb.) 45" ELBOW 80050 3/4" 3/8" 40 0.08 T/O 80051 1" 3/8" 40 0.11 80052 1-1/4" 3/4" 40 0.20 80053 1-1/2" 1/2' 80 0.31 T/O,!!!� 80054 2" 3/4" 80 0.56 80055 2-1/2" 13/16" 80 0.89 80056 3" 1" 80 1.19 80075 3/4" 1/8" 40 0.07 COUPLING & 80076 1" 1/8" 40 0.11 REDUCING COUPLING 80077 1-1/4" 3/16" 40 0.12 80078 1-1/2" 3/16' 80 0.25 80079 2" 3/16" 80 0.38 80080 2-1/2" 1/4" 80 0.67 T/O 80081 3" 3/16" 80 0.91 80220 1" x 3/4" 1/8" 40 0.08 80200 1" x 3/4" 7/16" 40 0.04 80201 1-1/4" x 3/4" 1/2" 40 0.11 80202 1-1/4" x 1" 5/16" 40 0.12 80203 1-1/2" x 3/4" 5/8" 80 0.16 80204 1-1/2" x 1" 1/2" 80 0.14 REDUCER BUSHING 80205 1-1/2" x 1-1/4" 3/8" 80 0.17 80206 2" x 3/4" 13/16" 80 0.27 80207 2" x 1" 11/16' 80 0.26 80208 2" x 1-1/4" 9/16" 80 0.24 80209 2"x1-1/2" 7/16" 80 0.19 T/O 80215 2-1/2" x 1" 15/16" 80 0.42 80214 2-1/2" x 1-1/4" 13/16" 80 0.45 80213 2-1/2" x 1-1/2" 11/16" 80 0.46 80211 2-1/2" x 2" 5/8" 80 0.29 80210 3" x 2" 3/4" 80 0.72 80212 3" x 2-1/2" 1/2" 80 0.47 CAP 80100 3/4" 5/16" 40 0.04 80101 1" 3/8" 40 0.06 80102 1-1/4" 7/16" 40 0.10 80103 1-1/2" 11/16" 80 0.20 80104 2" 5/8" 80 0.31 T/O 80105 2-1/2" 7/8" 80 0.58 80106 3" 1" 80 0.88 GROOVED T/O PIPE O.D. COUPLING ADAPTER 2-5/16" 1-1/4" (1.660") 80160 1-1/4" x 1-1/4" Groove 40 0.78 80161 1-1/2" x 1-1/2" Groove 2-5/16" 1-1/2" (1.900") 80 0.95 PIPE 80162 2" x 2" Groove 2-5/16" 2" (2.375") 80 1.42 O.D. 80163 2-1/2" x 2-1/2" Groove 2-5/16" 2-1/2" (2.875") 80 2.28 80164 3" x 3" Groove 2-1/4" 3" (3.500") 80 3.00 T/O -I 80169 2-1/2" x 76,1 mm Groove 2-5/16" 76,1 mm (3.000") 80 2.28 FIGURE 2 - FITTING DIMENSIONS (Part 2 of 4) TFP1915 Page 5 of 6 FITTING PART NOMINAL TAKE-OUT WEIGHT TYPE NUMBER NOMINAL SIZE (T/O) SCHD. (lb.) SPRINKLER HEAD ADAPTER 80175E 3/4" x 112" NPT 7/16" 80 0.20 80176E 1" x 1/2" NPT 7/16" 80 0.22 80175WL 3/4" x 1/2" NPT 7/16" 40 0.16 80179 1" x 3/4" NPT 13/16" 40 0.43 T/O SPRINKLER HEAD ADAPTER 80175W 3/4" x 112" NPT 1/2" 40 0.19 T/O 80176W 1" x 1/2" NPT 1/2" 40 0.18 SPRINKLER HEAD ADAPTER (SPIGOT) 80177L 3/4" x 1/2" NPT 1/2" 40 0.16 80178 1" x 1/2" NPT 9/16" 40 0.20 80180 1"x 3/4" NPT 7/8" 40 0.40 T/O FEMALE ADAPTER 80142 3/4" x 3/4" NPT 13/16" 40 0.41 80145 1' x 1" NPT 7/8" 40 0.63 80146 1-1/4" x 1-1/4" NPT 1-1/8" 40 1.03 80147 1-1/2" x 1-1/2" NPT 1-3/8" 80 1.42 80148 2" x 2" NPT 1-11/16" 80 2.66 —T/O MALE ADAPTER 80157 3/4" x 3/4" NPT 1-5/16" 40 0.33 80158 1' x 1" NPT 1-3/8" 40 0.56 T/O A XxYxZ X Y Z SPRINKLER HEAD ADAPTER TEE 80250 3/4" x 3/4" x 1/2" NPT 9/16" 9/16" 1" 40 0.22 Z 80251 1" x 1" x 1/2" NPT 11/16" 11/16" 1-3/16" 40 0.29 T/O 80249 1" x 1" x 1" NPT 15/16" 15/16" 1-9/16" 40 0.73 80256 1-1/4" x 1" x 1/2" NPT 7/16" 9/16" 1-5/16" 40 0.30 80252 1-1/4" x 1-1/4" x 1/2" NPT 7/16" 7/16" 1-5/16" 40 0.31 80257 1-1/2" x 1-1/4" x 1/2" NPT 1/2" 11/16" 1-7/16" 80 0.43 X Y, 80254 1-1/2" x 1-1/2" x 1/2" NPT 1/2" 1/2" 1-7/16" 80 0.46 T/O T/O 80258 2" x 1-1/2" x 1/2" NPT 1/2" 5/8" 1-11/16" 80 0.56 80253 2" x 2" x 1/2" NPT 1/2" 1/2" 1-11/16" 80 0.62 FIGURE 2 — FITTING DIMENSIONS (Part 3 of 4) Page 6 of 6 TFP1915 FITTING TYPE PART NUMBER NOMINAL SIZE NOMINAL TAKE-OUT (T/O) SCHD. WEIGHT (Ib.) BACK-TO-BACK TEE X x Y x Z X Y, Z X T/O 4j Y 1 80459 1" x 1/2" NPT x 1/2" NPT 5/8" 1-5/16" 40 0.48 80460 1" x 1/2" NPT x 1/2" NPT 5/8" 1-3/16" 40 0.46 Z T/O T/O BACK-TO-BACK CROSS X X Y X Z X W X, Y Z, W X T/O i iZ 80462 1" x 1" x 1/2" NPT x 1/2" NPT 5/8" 1-3/16" 40 0.46 w} I 80463 1" x 1" x 1/2" NPT x 1/2" NPT 5/8" 1-5/16" 40 0.47 T/O Y T/O T/O SPRINKLER HEAD X x Y X Y ADAPTER 90° ELBOW Y T/O 80199 3/4" x 1/2" NPT 9/16" 1" 40 0.20 80198 1" x 1/2" NPT 3/4" 1-1/4" 40 0.26 X I 80196 1" x 3/4" NPT 1-1/16" 1-7/16" 40 0.26 — T/O FIGURE 2 — FITTING DIMENSIONS (Part 4 of 4) Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantabilitv and fitness for a Dar - This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 SPEARS FlameGuard' CP VC FIRE SPRINKLER PIPING PRODUCTS TECHNICAL INFORMATION WEIGHTS & DIMENSIONS f�C�E�R� T/PAR I= Assessed to ISO 9001: 2008 Certificate number 293 November 2015 SUPERSEDES ALL PREVIOUS EDITIONS ACT G FG-4-1115 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS The information contained in this section is based on current information and Product design at the time of publication and is subject to change without notification. Our ongoing commitment to product improvement may result in some variation. No representations, guarantees or warranties of any kind are made as to its accuracy, suitability for particular applications or results to be obtained therefrom. For verification of technical data or additional information not contained herein, please contact Spears® Technical Services Department [West Coast: (818) 364-1611—East Coast: (678) 985-1263]. General Information RECOMMENDATIONS FOR INSTALLERS AND USERS: Plastic piping systems should be ENGINEERED, INSTALLED and OPERATED in accordance with ESTABLISHED DESIGN AND ENGINEERING STANDARDS AND PROCEDURES for plastic piping systems. Suitability for the intended service application should be determined by the installer and/or user prior to installation of a plastic piping system. All Installation and maintenance personnel should be trained in the proper handling and installation requirements and precautions of plastic piping systems. PRIOR TO ASSEMBLY, all piping system components should be inspected for damage or irregularities. Mating components should be checked to assure that tolerances and engagements are compatible. Do not use any components that appear irregular or do not fit properly. Contact the appropriate manufacturer of the component product in question to determine usability. Consult all applicable codes and regulations for compliance prior to installation. Installation must be made in accordance with Spears® Manufacturing Company FlameGuard® CPVC Fire Sprinkler Piping Products Installation Instructions - FG-3 NOTE — Individual or group instruction in correct solvent welding procedures is available by contacting your local distributor or your servicing Spears® Regional Distribution Center. SOLVENT CEMENT CONNECTIONS — Spears® Manufacturing Company recommends the use of Spears® FS-5 One Step solvent cement for joining Spears® products. Use of solvent cementing products not approved for CPVC fire sprinkler systems, or failure to follow installation instructions will automatically void the warranty. THREADED CONNECTION — Spears® Manufacturing Company recommends the use of Spears® BLUE 75TM Thread Sealant. This product has been tested by Spears® and the sealant manufacturer for compatibility with the Spears® CPVC fire sprinkler products. Consult the sprinkler head manufacturer before using this product. WARNING: OTHER PIPE JOINT COMPOUNDS OR PASTES MAY CONTAIN SUBSTANCES THAT COULD CAUSE STRESS CRACKING IN THE CPVC OR OTHER FITTING COMPONENTS. Care must be taken to avoid over torquing - generally 1 to 2 turns beyond finger tight is all that is required to make up a threaded connection. Factory testing has indicated 10-25 ft. lbs. of torque is adequate to obtain a leak free seal. GASKET SEALED THREAD CONNECTIONS — This type of connection can only be made with Spears@ TorqueSafe TM, SofTorqueTM or QuickTorqueTM style Gasket Sealed Female Sprinkler Adapters. DO NOT USE ANY TYPE OF THREAD SEALANT WHEN INSTALLING THIS TYPE OF ADAPTER. Tape or paste may impair proper sealing and function. Testing has shown that hand tight until snug for the TorqueSafeTm adapter and finger tight plus 1-turn is all that is needed to seal this special connection. Sprinkler heads in these specialty fittings can then be additionally tightened clockwise to bring sprinkler frames into desired alignment without stressing the fitting. See specific adapter instructions in package for details. GripLocTm CONNECTIONS — This type of connection can only be made with Spears@ GripLocTM Couplings or Repair Couplings. DO NOT USE ANY TYPE OF SOLVENT CEMENT OR SEALANT WHEN INSTALLING THIS TYPE OF CONNECTION. Uses an internal stainless steel gripper ring with an internal elastomer gasket seal. Connection allows immediate system use. See specific instructions in package for details. Installation Training Available - Contact Spears® Technical Services for Details FlameGuard® Products must be installed in accordance with Spears® FlameGuard® CPVC Fire Sprinkler Piping Products Installation Instructions, National Fire Protection Association Standards 13, 13R, 13D, and in accordance with local codes. Code requirements and field conditions may differ. It is the responsibility of the installing contractor to insure that the product is suitable to meet these requirements. Dimension Reference G = (LAYING LENGTH) Intersection of center lines to bottom of socket/thread; 90' elbows, tees, crosses; ± 1/32 inch. M = Outside diameter of socket/thread hub; ± 1/16 inch. H = Intersection of center lines to face of fitting; 90° elbows tees, crosses; ± 1/32 inch. N = Socket bottom to socket bottom; couplings; ± 1/16 inch. J = Intersection of center lines to bottom of socket/thread; 45' elbows; ± 1132 inch Q = Width of flats; ±1/16 inch. L = Overall length of fittings; ± 1/16 inch. W = Height of cap; ± 1/16 inch. CPVC FIRE SPRINKLER PIPE SDR 13.5 (ASTM F 442) Part Number Nominal Size Average O.D. I Average I.D. Approx. Weight Lbs./Ft. Inches (mm) Inches (mm) Inches (mm) CP-007 3/4 (19.1) 1.050 (26.7) .874 (22.5) 0.168 CP-010 1 (25.4) 1.315 (33.4) 1.101 (28.2) 0.262 CP-012 1-1/4 (31.8) I 1.660 (42.2) 1.394 (35.6) 0.418 CP-015 1-1/2 (38.1) 1.900 (48.3) 1.598 (40.7) 0.548 CP-020 2 (50.8) 2.375 (60.3) 2.003 (50.9) 0.859 CP-025 2-1/2 (63.5) 2.875 (73.0) 2.423 (61.5) 1.257 CP-030 3 (76.2) 3.500 (88.9) 2.950 (75.0) 1.867 "Lead Free" low lead certification — unless other wise specified, all Spears® FlameGuard® fittings specified here -in are certified by NSF International to ANSI/NSF® Standard 61, Annex G and is in compliance with California's Health & Safety Code Section 116825 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content-0.25%. Spears® PVC and CPVC Pipe, Fittings and Valves have always been lead-free and Certified by NSF International for use in potable water systems. Spears® offers a wide range of lead-free specialty fittings and transition adapters for plumbing applications. However, certain brass threaded adapter fittings for applications that are not intended to convey water for human consumption through drinking or cooking are still produced and available. SPEARS® MANUFACTURING COMPANY FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS El SOCKET DIMENSIONS �~ C SCH 40 - ASTM F438 SCH 80 - ASTM F439 B A Socket Socket SCH 40 Minimum SCH 80 Minimum Size Tolerance Entrance A Bottom B Socket Length C Socket Length C 3/4 1.058 1.046 ± .004 .719 1.000 1 1.325 1.130 ± .005 .875 1.125 1-1/4 1.670 1.655 ±.005 .938 1.250 1-1/2 1.912 1.894 ± .006 1.094 1.375 2 2.387 2.369 ± .005 1.156 1.500 2-1/2 2.889 2.868 ± .007 1.750 1.750 3 3.516 3.492 ± .008 1.875 1.875 TEE Socket x Socket x Socket 1 I M - - I- 1 Hr(�j L H L Part Number Size G H L M Approx. Wt. (Lbs.) 4201-007 3/4 9/16 1-1/2 2-31/32 1-5/16 .11 4201-010 1 7/8 1-13/16 3-5/8 1-5/8 .20 4201-012 1-1/4 15/32 2-3/32 4-7/32 2 .29 4201-015 1-1/2 1-5/32 2-9/16 5-3/32 2-11/32 .54 4201-020 2 1-13/32 2-15/16 5-7/8 2-7/8 .86 4201-025 2-1/2 1-23/32 3-1/2 7 3-15/32 1.62 4201-030 3 2-1/16 3-31/32 7-15/16 4-5/32 2.53 REDUCING TEE [--tml Socket x Socket x Socket H1 } M - - M2 G1 LGHt2-- Part Approx. Size G G1 G2 H H1 H2 L M M1 M2 Number Wt. (Lbs.) 4201-102 3/43/41 3/4 3/4 3/4 1-11/16 1-25/32 1-11/16 3-13/32 1-5/16 1-21/32 1-5/16 .13 4201-125 1x3/43/4 23/32 7/8 23/32 1-25/32 1-13/16 1-21/32 3-7/16 1-19/32 1-11/32 1-5/16 .16 4201-126 1xNA 23/32 23/32 3/4 1-27/32 1-27/32 1-3/4 3-19/32 1-5/8 1-5/8 1-5/16 .17 4201-131 1x1x3/4 11/16 13/16 11/16 1-13/16 1-13/16 1-13/16 3-5/8 1-5/8 1-5/16 1-5/8 .17 4201-157 1-1/410/4 11/16 1-1/32 11/16 1-15/16 2-1/32 1-13/16 3-25/32 2-3/32 1-13/32 1-23/32 .32 MADE IN THE U.S.A. El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS REDUCING TEE (continued) Socket x Socket x Socket HI 1 M - M2 1 + G1 G2 H fH2� L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4201-158 1-1/4xlxl 27/32 29/32 25/32 2-1/16 2-1/32 1-29/32 3-15/16 1-31/32 1-5/8 1-5/8 .24 4201-159 1-1/4xlxl-1/4 31/32 31/32 31/32 2-7/32 2-7/32 2-3/32 4-11/32 2-1/8 2-1/8 1-23/32 .36 4201-167 1-1/41-1/43/4 21/32 1 21/32 1-29/32 2 1-29/32 3-13/16 2 1-5/16 2 .22 4201-168 1-1/41-1/41 13/16 1 13/16 2-1/16 2-1/8 2-1/16 4-1/8 1-31/32 1-21/32 1-31/32 .24 4201-169 1-1/4x1-1/4x1-1/2 1-1/8 15/16 1-1/8 2-3/8 2-11/32 2-3/8 4-3/4 2-3/32 2-11/32 2-3/32 .51 4201-201 1-1/2xl-1/43/4 11/16 1 1/4 2-1/16 2 1-15/16 4 2-5/16 1-3/8 2-1/16 .41 4201-202 1-1/2xl-1/4xl 27/32 1-1/32 1 2-7/32 2-5/32 2-1/4 4-15/32 2-5/16 1-11/16 2-1/16 .42 4201-210 1-1/2xl-1/20/4 11/16 1-1/32 11/16 2-1/16 2-1/32 2-1/16 4-5/32 2-11/32 1-13/32 2-11/32 .39 4201-211 1-1/2xl-1/2xl 13/16 1-3/32 13/16 2-3/16 2-1/4 2-3/16 4-3/8 2-11/32 1-3/4 2-11/32 .41 4201-212 1-1/2xl-1/2xl-1/4 1-1/32 1-3/32 1 1-1/32 2-13/32 2-11/32 2-13/32 4-13/16 2-11/32 2-1/8 2-11/32 .49 4201-213 1-1/2xl-1/2x2 1-9/32 1-5/32 1-9/32 2-21/32 2-21/32 2-21/32 5-11/32 2-11/32 2-29/32 2-11/32 .64 4201-248 2x2x3/4 11/16 1-13/32 11/16 2-7/32 2-7/16 2-7/32 4-7/16 2-27/32 1-3/8 2-27/32 .52 4201-249 2x2xl 27/32 1-13/32 27/32 2-11/32 2-9/16 2-11/32 4-23/32 2-7/8 1-3/4 2-7/8 .58 4201-250 2x2xl-1/4 1-1/32 1-11/32 1-1/32 2-17/32 2-19/32 2-17/32 5-3/32 2-7/8 2-3/32 2-7/8 .65 4201-251 2x2xl-1/2 1-5/32 1-7/16 1-5/32 2-11/16 2-13/32 2-11/16 5-3/8 2-7/8 2-13/32 2-7/8 .79 4201-289 2-1/2x2-1/2xl 27/32 1-23/32 27/32 2-5/8 2-27/32 2-5/8 5-1/4 3-17/32 1-23/32 3-17/32 1.01 4201-290 2-1/2x2-1/2xl-1/4 1-3/32 1-23/32 1-1/32 2-13/16 2-31/32 2-13/16 5-21/32 3-9/16 2-3/32 3-9/16 1.13 4201-291 2-1/2x2-1/2xl-1/2 1-3/16 1/2 1-3/16 2-15/16 1-7/8 2-15/16 5-7/8 3-15/32 2-11/32 3-15/32 1.26 4201-292 2-1/2x2-1/2x2 1-13/32 1-5/8 1-13/32 3-3/16 3-1/8 3-3/16 6-3/8 3-1/2 2-7/8 3-1/2 1.37 4201-335 3x3xl 7/8 1-15/16 7/8 2-3/4 3-1/16 2-3/4 5-15/32 4-3/16 1-23/32 1 4-3/16 1.26 4201-336` 3x3xl-1/4 1-3/8 1-3/4 1-3/8 3-5/16 3-1/2 3-5/16 6-5/8 4-1/8 2-7/8 4-1/8 1.94 4201-337 3x3xl-1/2 1-5/32 2-1/16 1-5/32 3-1/32 3-7/16 3-1/32 6-3/32 4-3/16 2-3/8 4-3/16 1.46 4201-338 3x3x2 1-7/16 1-13/16 1-7/16 3-5/16 3-5/16 3-5/16 6-19/32 4-3/16 2-7/8 4-3/16 1.69 4201-339 3x3x2-1/2 1-3/4 1-31/32 1-3/4 3-5/8 3-23/32 3-5/8 7-1/4 4-3/16 3-17/32 4-3/16 2.11 Branch Outlet Sized with Bushing TorqueSafeTM SPRINKLER HEAD TEE Gasket Sealed Brass M1 Thread Insert Style G1-1 Socket x Socket x Gasket Fipt With Elastomer Seal - Use NO Thread Sealant / H1 MI2 M - - + - G -- G2 1 H H2 _-L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4202-101 G 3/43/41/2 7/16 1-3/16 7/16 1-7/16 1-7/16 1-17/32 2-29/32 1-3/8 1-3/8 1-3/8 .22 4202-124 G 10/41/2 7/16 1-11/32 9/16 1-9/16 1-11/16 1-9/16 3-1/8 1-11/16 1-3/8 1-3/8 .26 4202-130G 1x1x1/2 7/16 1-11/32 7/16 1-9/16 1-11/16 1-9/16 3-1/8 1-23/32 1-3/8 1-23/32 .28 4202-131 G 1xWA 17/32 15/16 17/32 1-11/16 1-5/8 1-11/16 3-11/32 1-23/32 1-9/16 1-23/32 .31 4202-166 G 1-1/41-1/4x1/2 7/16 1-5/8 7/16 1-11/16 1-15/16 1-11/16 3-3/8 2-1/16 1-3/8 2-1/16 .34 4202-209 G 1-1/2x1-1/2x1/2 1/2 1-13/16 1/2 1-7/8 2-3/32 1-7/8 3-3/4 2-11/32 1-3/8 2-11/32 .41 4202-247 G 2x2xl/2 1/2 2-1/16 1/2 2 2-11/32 2 4-1/32 2-27/32 1-3/8 2-27/32 .54 Not intended to convey or dispense water for human consumption through drinking or cooking SPEARS® MANUFACTURING COMPANY FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS El SPRINKLER HEAD TEE Brass Thread Insert Style Socket x Socket x Fipt H1 ffjG1 M —2 G G2 f H H2 � L Part Number Size G G1 G2 H H1 I H2 L M M1 M2 Approx. Wt. 4202-010 1x1x1 1 21/31 1 1-1/8 1 21/31 1 1-25/32 1 1-29/32 1 1-25/32 1 3-19/32 1 1-23/32 1 1-23/32 1 1-23/32 1 .37 Not intended to convey or dispense water for human consumption through drinking or cooking SofTorqueTM SR REDUCING TEE Gasket Sealed Special Reinforced Plastic Thread Style Socket x Socket x SR Fipt M1 With Elastomer Seal - Use NO Thread Sealant , H1 T �— M ---- —.—.—Mz G G2 H H22 f� L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4202-101GSR 3/43/41/2 7/16 1-1/2 7/16 1-3/8 1-7/8 1-3/8 2-3/4 1-5/16 1-3/8 1-5/16 .16 4202-130GSR 1x1x1/2 7/16 1-5/8 7/16 1-1/2 2 1-1/2 3 1-5/8 1-3/8 1-5/8 .20 SPRINKLER REDUCING HEAD TEE Brass Thread Insert Style Socket x Socket x Fipt -M1—{ t H1 M — G1 LEiEl GH H2 2 L Part Number Size G G1 G2 H H1 H2 L M M1 I M2 Approx. Wt. (Lbs.) 4202-101 3/4x3/4xl/2 7116 1-1/16 7/16 1-15/32 1-5/8 1-15/32 2-29/32 1-13/32 1-3/16 1-13/32 .20 4202-124 1x3/41/2 7/16 1-11/32 9/16 1-9/16 1-11/16 1-9/16 3-1/8 1-11/16 1-3/8 1-3/8 .26 4202-130 1x1x1/2 7/16 1-7/32 7116 1-9/16 1-25/32 1-9/16 3-1/8 1-3/4 1-3/16 1-3/4 .26 4202-156 1-1/4x1x1/2 7/16 1-7/16 9/16 1-11/16 2-1/32 1-11116 3-3/8 2-3/32 1-3/16 1-23/32 .30 4202-166 1-1/4xl-1/4xl/2 7/16 1-15/32 7116 1-11/16 1 2-1/32 1-11/16 3-3/8 2-3/32 1-3/16 2-3/32 .31 4202-199 1-1/2xl-1/41/2 1/2 1-5/8 9/16 1-7/8 2-3/16 1-13/16 3-11/16 2-11132 1-3/16 2-1/16 .37 4202-209 1-101-1/202 1/2 1-5/8 1/2 1-7/8 2-3/16 1-7/8 3-3/4 2-11/32 1-3/16 2-11/32 .38 4202-237 2x1-101/2 1/2 1-27/32 17/32 2 2-7/16 1-29/32 3-15/16 2-7/8 1-3/16 2-11132 .47 4202-247 2x2xl/2 1/2 1-7/8 1/2 2 2-7/16 2 4-1/32 2-27/32 1-3/16 2-27/32 .50 Not intended to convey or dispense water for human consumption through drinking or cooking MADE IN THE U.S.A. El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS SPRINKLER HEAD TEE Special Reinforced Plastic Thread Style Socket x Socket x SR Fipt I, L I Part Number Size G G1 G2 H H1 H2 I L I M I M1 M2 Approx. Wt. (Lbs.) 4202-010SR 1xlxl 21/32 3/4 21/32 1-25/32 1-5/8 1-25/32 3-19/32 1-23/32 1-11/16 1-23/32 .26 SPRINKLER REDUCING HEAD TEE Special Reinforced Plastic Thread Style Socket x Socket x SR Fipt �M1� f H1 MD"77 M2 G1 G G2 �H�IH2� �L Part Number Size G G1 G2 H 1-11 H2 L M M1 M2 Approx. Wt. (Lbs.) 4202-101SR 3/43/41/2 19/32 25/32 19/32 1-19/32 1-7/16 1-19/32 3-7/32 1-13/32 1-3/16 1-13/32 .15 4202-124SR 1x3/4xl/2 7/16 29/32 9/16 1-19/32 1-5/8 1-9/16 3-5/32 1-23/32 1-3/16 1-17/32 .19 4202-130SR 1x1x1/2 7/16 29/32 7/16 1-9/16 1-5/8 1-9/16 3-1/8 1-23/32 1-3/16 1-23/32 .20 4202-156SR 1-1/4x1x1/2 15/32 1-5/32 19/32 1-23/32 1-7/8 1-23/32 3-13/32 2-3/32 1-3/16 1-23/32 .26 4202-166SR 1-1/41-1/41/2 7/16 1-1/8 7/16 1-11/16 1-27/32 1-11/16 3-3/8 2-3/32 1-3/16 2-3/32 .26 4202-168SR 1-1/41-1/41 27/32 1-1/32 27/32 2-3/32 1-29/32 2-3/32 4-7/32 2-3/32 1-11/16 2-3/32 .34 4202-199SR 1-1/2xl-1/41/2 9/16 1-9/32 17/32 1-15/16 2 1-25/32 3-23/32 2-11/32 1-3/16 2-3/32 .33 4202-209SR 1-1/2xl-1/2xl/2 1/2 1-1/4 1/2 1-7/8 1-31/32 1-7/8 3-3/4 2-11/32 1-3/16 2-11/32 .35 4202-211 SR 1-1/2xl-112xl 27/32 1-7/32 27/32 2-7/32 2-1/8 2-7/32 4-15/32 2-11/32 1-23/32 2-11/32 .44 4202-237SR 2x1-1/2x1/2 23/32 1-9/16 3/8 2-7/32 2-9/32 1-3/4 3-31/32 2-7/8 1-3/16 2-11/32 1 .45 4202-247SR 2x2x1/2 1/2 31/32 1/2 2 1-11/16 1 19/32 1 4 2-7/8 1 1-3/16 2-7/8 1 .48 4202-287SR 2-1/2x2-1/2xl/2 17/32 1-3/4 17/32 2-9/32 2-1/2 1 2-9/32 1 4-19/32 3-1/2 1 1-7/32 3-1/2 1 .78 SOFTORQU ETM SR SPRINKLER HEAD TEE I~M1� Gasket Sealed Special Reinforced Plastic Thread Style _ ___ M - 1 H1 ! __._ M2 Socket x SR Fipt x Socket Stainless Steel Collar With Elastomer Seal - Use + NO Thread Sealant "�L H2�Z Part Number Size I G I G1 I G2 I H 1 1-11 H2 I L I M M1 I M2 I Approx. Wt. (Lbs.) 4203-122GSR 1xl/2x1 1 13/16 1 13/16 1 1-1/2 1 1-27/32 1 1-27/32 1 1-31/32 1 3-13/16 1 1-5/8 1-5/8 1 1-3/8 1 .22 5 SPEARS® MANUFACTURING COMPANY FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS TorqueSafeTM M1� SPRINKLER HEAD TEE Gasket Sealed — G1-1 1 H1 Brass Thread Insert Style 1 Socket x Gasket Fipt x Socket P�-- 411H2 With Elastomer Seal - Use NO Thread Sealant Part Number I Size I G I G1 I G2 H H1 I H2 I L M M1 M2 Approx. Wt. (Lbs.) 4203-122 G I 1xl/2x1 1 19/32 1 13/16 1 1-13/32 1 1-19/32 1 1-27/32 1 1-3/4 1 3-11/32 1 1-5/8 1 1-5/8 1 1-3/8 1 .25 Not intended to convey or dispense water for human consumption through drinking or cooking SPRINKLER HEAD TEE M1 �I Brass Thread Insert Style Socket x Fipt x Socket G1 1 t HI1 i + M — +- 2 G2 —H H2� L Part Number Size I G I G1 G2 I H H1 H2 I L I M M1 M2 Approx. Wt. (Lbs.) 4203-122 lxl/2x1 23/32 1 3/4 1-1/4 1 1-5/8 1-5/8 1-15/16 1 3-1/2 1 1-23/32 1 1-23/32 1 1-3/16 1 .25 Not intended to convey or dispense water for human consumption through drinking or cooking SPRINKLER HEAD TEE Special Reinforced Plastic Thread Style Socket x SR Fipt x Socket M1�I H1 t Mir L L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4203-122SR 1xl/2xl 27/32 23/32 1-3/32 1-23/32 1-5/8 1-25/32 3-13/32 1-3/4 1-3/4 1-3/16 .21 MADE IN THE U.S.A. 6 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS STREET TEE Spigot x Socket x Socket �M1� 0 of M2 f HI 1 I — —J— G1 G G2 Ham_ H2 L —: Part Number Size G G1 G2 H H1 H2 L M1 M2 Approx. Wt. (Lbs.) 4244-007 3/4 13/16 27/32 27/32 1-13/16 1-7/8 1-7/8 3-5/8 1-13/32 1-13/32 .16 4244-010 1 1-5/32 1-1/32 1-1/32 2-1/8 1-29/32 1-29/32 4-3/16 1-3/4 1-3/4 .27 4244-012 1-1/4 1-1/4 1 1 2-7/16 2-9/32 2-9/32 4-27/32 2-3/32 2-3/32 .42 4244-015 1-1/2 1-13/16 1-1/8 1-1/8 2-7/8 2-9/16 2-9/16 5-11/32 2-11/32 2-11/32 .56 4244-020 2 1-23/32 1-7/16 1-13/32 3-1/4 2-15/16 2-15/16 6-5/32 2-7/8 2-7/8 .84 900 ELBOW Socket x Socket G r H � F �M--� Part Number Size G H M Approx. Wt. (Lbs.) 4206-007 3/4 9/16 1-1/2 1-5/16 .07 4206-010 1 3/4 1-5/8 1-5/8 .11 4206-012 1-1/4 15/16 2-3/16 2 .22 4206-015 1-112 1-5/32 2-17/32 2-3/8 .41 4206-020 2 1-13/32 2-29/32 2-7/8 .62 4206-025 2-1/2 1-15/32 3-3/8 3-1/2 1.15 4206-030 3 1-5/32 3-3/32 4-3/16 1.83 SPEARS° MANUFACTURING COMPANY =FicameGuardO CPVC FIRE SPRINKLER PIPING PRODUCTS SIDE OUTLET ELBOW Socket x Socket x Socket M G H Part Number Size G H M Approx. Wt. (Lbs.) 4213-007 3/4 27/32 1-19/32 1-5/16 .09 4213-010 1 13/16 1-7/8 1-5/8 .18 REDUCING 900 ELBOW H1 Socket x Socket G1— G - M1 HI L Part Number Size G G1 H H1 M M1 Approx. Wt. Lbs. 4206-131 1x3/4 21/32 13/16 1-25/32 1-13/16 1-19/32 1-5/16 .11 TorqueSafeTM 900 SPRINKLER HEAD ELBOW Gasket Sealed Brass Thread Insert Style Socket x Gasket Fipt With Elastomer Seal - Use NO Thread Sealant �H1 G1 G 1� M1 I 1 M Part Number Size G G1 H H1 M M1 Approx. Wt. (Lbs.) 4207-101 G 3/41/2 9/16 1-7/32 1-13/32 1-17/32 1-13/32 1-3/8 .19 4207-130 G 1x1/2 7/16 1-3/16 1-9/16 1-11/16 1-23/32 1-3/8 .23 4207-166 G 1-1/4x1/2 15/32 1-19/32 1-15/16 1-11/16 2-3/32 1-3/8 .25 Not intended to convey or dispense water for human consumption through drinking or cooking MADE IN THE U.S.A. 8 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS SPRINKLER HEAD 900 ELBOW Brass Thread Insert Style H1— Socket x Fipt G1 G --- M1 _ H �I I I�M� Part Number Size G G1 H H1 M M1 Approx. Wt. (Lbs.) 4207-101 3/41/2 1/2 1-3/32 1-1/2 1-5/8 1-13/32 1-3/16 .17 4207-130 1x1/2 7/16 1-7/32 1-19/32 1-25/32 1-23/32 1-3/16 .21 4207-131 1x3/4 17/32 1-11/32 1-21/32 1-31/32 1-23/32 1-3/8 .25 4207-166 1-1/41/2 15/32 1-17/32 1-11/16 1-15/16 2-3/32 1-17/32 .33 Not intended to convey or dispense water for human consumption through drinking or cooking SofTorqueTM SR 900 ELBOW SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Socket x SR Fipt H1 With Elastomer Seal - Use NO Thread Sealant c1 G H i L M Part Number Size G G1 H H1 M M1 Approx. Wt. (Lbs.) 4207-101GSR 3/41/2 7/16 1-17/32 1-3/8 1-27/32 1-11/32 1-3/8 .17 4207-130GSR 1x1/2 7/16 1-11/16 1-1/2 2 1-21/32 1-3/8 .19 4207-166GSR 1-1/4xl/2 7/16 1-7/8 1-11/16 2-7/32 2 1-3/8 .22 SPRINKLER HEAD 900 ELBOW Special Reinforced Plastic Thread Style �H1� Socket x SR Fipt G1 G — 2 +1 H Part Number Size G G1 H H1 M M1 Approx. Wt. (Lbs.) 4207-101SR 3/41/2 11/32 13/16 1-15/32 1-1/2 1-13/32 1-3/16 .14 4207-130SR 1x1/2 7/16 7/8 1-9/16 1-5/8 1-23/32 1-3/8 .20 4207-131SR 1x3/4 1/2 7/8 1-5/8 1-9/16 1-23/32 1-3/8 .16 4207-166SR 1-1/41/2 1 13/32 1 1-1/32 1-21/32 1 1-23/32 1 2-3/32 1 1-7/32 1 .19 SPEARS® MANUFACTURING COMPANY FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS El 900 STREET ELBOW Spigot x Socket H1� G1 7 M1 fG H I.►� PIPE O.D. Part Number Size G G1 H H1 M1 Approx. Wt. (Lbs.) 4209-007 3/4 29/32 19/32 1-15/16 1-11/16 1-13/32 .12 4209-010 1 1-9/32 23/32 2-13/32 1-27/32 1-3/4 .21 4209-012 11-1/4 1 1-9/16 1 27/32 1 2-13/16 1 2-3/32 1 2-3/32 1 .32 4209-015 1-1/2 1-15/32 1-3/16 2-27/32 2-9/16 2-11/32 .42 4209-020 2 1-23/32 1-3/8 3-7/32 2-15/16 2-27/32 .65 22-1/20 ELBOW Socket x Socket ��lP I. M-I Part Number Size H J M Approx. Wt. (Lbs.) 4216-007 3/4 1-3/16 7/32 1-13/32 .09 4216-010 1 1-3/8 9/32 1-25/32 .14 4216-012 1-1/4 1-1/2 5/16 2-3/32 .20 4216-015 1-1/2 1-7/16 13/32 1-3/8 .19 4216-020 2 1-7/8 3/8 2-27/32 .43 4216-030 3 2-3/8 1/2 4-5/32 1.00 22-1/20 STREET ELBOW Spigot x Socket �— � M1 � H1 J1 iH J .1-PIPE O.D. Part Number Size H H1 J J1 M1 Approx. Wt. (Lbs.) 4242-007 3/4 1-1/4 1-1/2 1/4 1/2 1-3/8 .08 4242-010 1 1-7/16 1-11/32 5/16 7/32 1-23/32 .14 4242-012 1-1/4 1-9/16 1-25/32 17/32 11/16 2-1/16 .21 4242-015 1-1/2 1-13/32 1-23/32 1/2 11/32 2-11/32 .28 4242-020 2 1-29/32 2-1/8 7/32 5/8 2-7/8 .42 4242-025 2-1/2 2-1/8 2-1/4 13/32 1/2 3-1/2 .68 4242-030 3 2-13/32 2-13/32 9/16 17/32 4-5/32 .99 MADE IN THE U.S.A. 10 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS 450 ELBOW Socket x Socket I H Part Number Size H J M Approx. Wt. (Lbs.) 4217-007 3/4 1-5/16 5/16 1-5/16 .07 4217-010 1 1-13/32 3/8 1-5/8 .11 4217-012 1-1/4 1-5/8 3/8 2-5/32 .21 4217-015 1-1/2 1-27/32 15/32 2-11/32 .32 4217-020 2 2-1/8 21/32 2-7/8 .48 4217-025 2-1/2 2-17/32 3/4 3-1/2 .88 4217-030 3 2-29/32 29/32 4-5/32 1.17 CROSS Socket x Socket x Socket x Socket Gl� � � t i - H1 L1 �► H Part Number Size G G1 H H1 L L1 M Approx. Wt. (Lbs.) 4220-007 3/4 518 5/8 1-21/32 1-21132 3-5/16 3-5/16 1-13/32 .22 4220-010 1 3/4 3/4 1-5/8 1-5/8 3-1/4 3-1/4 1-23/32 .20 4220-012 1-1/4 1-1/8 1-1/8 2-3/8 2-3/8 4-3/4 4-3/4 2-3/32 .63 4220-015 1-1/2 1-7/32 1-7/32 2-5/8 2-5/8 5-7/32 5-7/32 2-3/8 .80 4220-020 2 1-1/2 1-1/2 3 3 6 6 3 1.43 4220-025 2-1/2 1-11/16 1-11/16 3-7/16 3-7/16 6-7/8 6-7/8 3-17132 2.16 4220-030 3 2-3/32 2-3/32 3-31/32 3-31/32 7-15/16 7-15/16 4-7/16 3.37 SPEARS° MANUFACTURING COMPANY FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS El 450 STREET ELBOW Spigot x Socket H1 J1 M1 r H� ►I PIPE O.D. Part Number Size H Hl i ill Ml Approx. Wt. Lbs. 4227-010 1 1-1/2 1-5/16 1/2 1/4 1-5/8 .10 4227-012 1-1/4 1-25/32 1-9/16 9/16 11/32 1-31/32 .15 4227-015 1-1/2 2-1/32 2-1/8 19/32 25/32 2-11/32 .29 4227-020 2 2-5/16 1-15/16 25/32 13132 2-7/8 .44 REDUCING i.-- r-M1 Socket x Socket x Socket x Socket f H1 L1 M -I=GPP 1► L Part Number Size G G1 H H1 L L1 M M1 Approx. Wt. (Lbs.) 4220-131 1x3/4 23/32 5/8 1-5/8 1-5/8 3-1/4 3-1/4 1-7/8 1-1/2 .31 4220-167 1-1/43/4 1-1/16 23/32 2-1/16 1-31/32 4-3/32 3-31/32 2-1/16 1-13132 .35 4220-210 1-1/2x3/4 11/16 1-5/32 2-3/32 2-3/16 4-3/16 4-11/32 2-3/8 1-13/32 .42 4220-248 2x3/4 11/16 1-7/16 2-7/32 2-7/16 4-13/32 4-7/8 2-29/32 1-13/32 .56 4220-289 2-1/2xl 29/32 1-3/4 2-11/16 2-7/8 5-11/32 5-3/4 3-1/2 1-3/4 .98 COUPLING Socket x Socket M N- Part Number Size L M N Approx. Wt. (Lbs.) 4229-007 3/4 2-1/8 1-5/16 3/16 .05 4229-010 1 2-3/16 1-5/8 3/32 .08 4229-012 1-1/4 2-19/32 2 3/32 .13 4229-015 1-1/2 2-7/8 2-11/32 3/32 .22 4229-020 2 3-1/8 2-7/8 1 /8 .33 4229-025 2-1/2 3-11 /16 3-15/32 3/16 .48 4229-030 3 4 4-3/16 1 /4 .89 MADE IN THE U.S.A. 12 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS REDUCER COUPLING Socket x Socket � 1 IM E M1 i —L N -� L Part Number Size L M M1 N Approx. Wt. (Lbs.) 4229-131 1x3/4 2-3/8 1-23/32 1-13/32 7/32 .10 4229-167 1-1/43/4 2-19/32 2-3/32 1-5/8 11/32 .17 4229-168 1-1/41 2-11/16 2-3/32 1-23/32 5/16 .18 4229-210 1-1/20/4 2-13/16 2-11/32 1-13/32 15/32 .19 4229-211 1-1/2xl 2-7/8 2-11/32 1-15/16 3/8 .24 4229-212 1-1/2xl-1/4 2-13/16 2-13/32 2-1/8 5/32 .23 4229-248 20/4 3-3/16 2-7/8 1-7/16 23/32 .32 4229-249 2x1 3-1/8 2-7/8 1-23/32 1/2 .31 4229-250 2xl-1/4 3-3/16 2-7/8 2-1/8 17/32 .33 4229-251 2xl-1/2 3-3/16 2-27/32 2-11/32 9/32 .31 4229-291 2-1/2xl-1/2 3-23/32 3-15/32 2-11/32 21/32 .51 4229-292 2-1/2x2 3-21/32 3-1/2 2-7/8 13/32 .52 4229-337 3x1-1/2 3-1/2 4-3/16 2-3/8 7/32 .71 4229-339 3x2-1/2 3-27/32 4-3/16 3-1/2 3/16 .80 GripLOCTM COUPLING - LEAD FREE w/EPDM 0-Ring Seals L 175 psi Maximum Internal Pressure @ 150°F Ar L1� WARNING: DO NOT INSERT FINGERS. Part Number Size L M1 N Approx. Wt. (Lbs.) GL4229-007 3/4 4 1-15/16 1-29/32 .25 GL4229-010 1 4-5132 2 2-1/4 .34 13 SPEARS° MANUFACTURING COMPANY FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS El GROOVED COUPLING ADAPTER Groove x Socket PIPE _ _ O.D. M1 1 L� Part Number Size L M1 N Approx. Wt. (Lbs.) 4233-012 1-1/4 3-5/8 2-3/32 2-11/32 .72 4233-015 1-1/2 3-3/4 2-11/32 2-11/32 .83 4233-020 2 3-27/32 2-27/32 2-11/32 1.27 4233-025 2-1/2 4-3/16 3-15/32 2-7/16 2.02 4233-030 3 4-5/16 4-1/8 2-7/16 2.76 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE ADAPTER Brass Thread Insert Style Socket x Fipt M L N M1 Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-007 3/4 2 1-13/32 1-3/8 5/16 .23 4235-010 1 2-3/16 1-3/4 1-11/16 11/32 .25 4235-012 1-1/4 2-3/8 2-3/32 2-1/16 3/8 .36 4235-015 1-1/2 2-17/32 2-3/8 2-7/16 3/8 .47 4235-020 2 2-25/32 2-27/32 3-3/16 7/16 1.05 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE ADAPTER Special Reinforced Plastic Thread Style Socket x SR Fipt M M1 Ll 1 ~ L Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-007SR 3/4 1-7/8 1-13/32 1-3/8 3/32 .08 4235-010SR 1 2-5/32 1-23/32 1-7/8 3/32 .22 4235-012SR 1-1/4 2-5/16 2-1/8 2-1/16 3/16 .20 MADE IN THE U.S.A. 14 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Socket x SR Fipt M --- - I M1 N L� Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-101SR 3/41/2 1-29/32 1-13/32 1-3/16 1/8 .08 4235-130SR 1x1/2 1-31/32 1-23/32 1-3/8 3/32 .16 4235-131SR 1x3/4 2-3/32 1-3/4 1-3/8 1/4 .13 FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style with Socket Wrench Flats Socket x SR Fipt I M — M1 M = Flat -to -Flat Dimension N �L� Part Number Size L M M1 N Approx. Wt. (Lbs.) W4235-101SR 3/41/2 2-9/32 1-13/32 1-3/16 17/32 .09 W4235-130SR 1x1/2 2-9/32 1-3/4 1-3116 13/32 .12 15 SPEARS" MANUFACTURING COMPANY FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS El SPIGOT FEMALE ADAPTER Brass Thread Insert Style Spigot x Fipt PIPE O.D. M1 � N��► L� 1 Part Number Size L M1 N Approx. Wt. (Lbs.) 4278-007 3/4 2-5/32 1-3/8 17/32 .15 4278-010 1 2-9/32 1-11 /16 7/16 .22 Not intended to convey or dispense water for human consumption through drinking or cooking SPIGOT FEMALE ADAPTER Special Reinforced Plastic Thread Style 1 _ 1 Spigot x SR Fipt PIPE O.D. 1 M1 Part Number Size L M1 N Approx. Wt. (Lbs.) 4278-007SR 3/4 1-15/16 1-3/8 11/32 .08 4278-010SR 1 2-1/4 1-23/32 13/32 .13 TorqueSafeTm FEMALE SPRINKLER HEAD ADAPTER Gasket Sealed Brass Thread Insert Style Socket x Gasket Fipt With Elastomer Seal - Use NO Thread Sealant M - — - —- M1 1 N—= L� Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-101 G 3/4xl/2 1-7/8 1-13/32 1-3/8 9/16 .15 4235-130GS 1 x1 /2 2-1 /32 1-11 /16 1-3/8 17/32 .17 4235-131 G 1x3/4 2 1-11/16 1-9/16 9/16 .18 Not intended to convey or dispense water for human consumption through drinking or cooking MADE IN THE U.S.A. 16 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style Socket x Fipt 1 1 M M1 N �► L Part Number Size L M M1 I N Approx. Wt. (Lbs.) 4235-101 I 3/41/2 1-7/8 1-13/32 1-17/32 I 15/32 .19 4235-130 I 1x1/2 2-11/32 1-11/16 1-3/16 I 5/8 .16 4235-131 I 1 x3/4 I 2-5/16 1-11/16 1-3/8 I 17/32 .18 Not intended to convey or dispense water for human consumption through drinking or cooking SofTorqueTM SR FEMALE SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Socket x SR Fipt With Elastomer Seal - Use NO Thread Sealant �L� M E — r N Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-101GSR 3/41/2 2-5/16 1-5/16 1-3/8 31/32 .11 4235-130GSR 1x1/2 2-13/32 1-19/32 1-3/8 31/32 .13 4235-131GSR 104 2-13/32 1-5/8 1-23132 1 .16 QuickTorqueTM SR FEMALE SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Socket x SR Metal Fipt With Elastomer Seal - Use NO Thread Sealant r ' r M — — Ila M1 Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-101GMR 3/41/2 1-15/16 1-5/16 1-9116 13/16 .17 4235-13OGMR 1x1/2 2-3/16 1-19/32 1-9/16 15/16 .19 17 SPEARS® MANUFACTURING COMPANY =FlcameGuardO CPVC FIRE SPRINKLER PIPING PRODUCTS FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style M 1 t�l with Long Body Socket x Fipt tJ N L Part Number Size L M M1 N Approx. Wt. (Lbs.) L4235-130 1 x1 /2 2-3/16 1-23/32 1-7/32 1 /2 .19 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE SPRINKLER HEAD ADAPTER _ Brass Thread Insert Style with Positioning Ring M M1 Socket x Fipt 1 N « L� Part Number Size L M M1 N Approx. Wt. (Lbs.) R4235-101 3/4112 2-1/32 1-7/16 1-3/16 15/32 .15 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style with Positioning Ring IM — M1 Socket x SR Fipt L� I N L� Part Number Size L M M1 N Approx. Wt. (Lbs.) R4235-101SR 3/41/2 1-15/16 1-7/16 1-7/32 7/32 .09 TorqueSafeTm FEMALE SPIGOT SPRINKLER HEAD ADAPTER Gasket Sealed Brass Thread Insert Style Spigot x Gasket Fipt With Elastomer Seal - Use NO Thread Sealant PIPE M1 N �► L� Part Number Size L M N Approx. Wt. (Lbs.) 4238-101 G 314xl/2 1-15/16 1-3/8 21/32 .14 4238-130 G 1x1/2 2-1/16 1-3/8 19/32 .15 Not intended to convey or dispense water for human consumption through drinking or cooking MADE IN THE U.S.A. 18 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS SPIGOT FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style Spigot x Fipt 1 PIPE O.D. M1 1 N -4. — L —1 Part Number Size L M1 N Approx. Wt. (Lbs.) 4238-101 3/4xl /2 1-15/16 1-17/32 17/32 .18 4238-130 1 x1 /2 2-1/4 1-3/16 11 /32 .19 Not intended to convey or dispense water for human consumption through drinking or cooking TorqueSafe"'I BUSHING - GASKET SEALED Brass Thread Insert Style Spigot x Gasket FIPT With Elastomer Seal - Use NO Thread Sealant PIPE _ O.D. I- � L Part Number Size L Approx. Wt. (Lbs.) 4238-130BR G 1x1/2 1-7/32 .10 Not intended to convey or dispense water for human consumption through drinking or cooking BUSHING with BRASS THREAD INSERT Spigot x Fipt j I PIPE O.D, 1 Part Number Size L Approx. Wt. (Lbs.) 4238-130BR 1 x1 /2 1 .13 Not intended to convey or dispense water for human consumption through drinking or cooking SPIGOT FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Fipt 11 PIPE O.D. N--I L� Part Number Size L M1 N Approx. Wt. (Lbs.) 4238-101SR 3/41/2 1-29/32 1-7/32 1/8 .07 4238-130SR 1 x1 /2 2-1 /32 1-7/32 7/32 .09 19 SPEARS" MANUFACTURING COMPANY FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS El MALE ADAPTER With CPVC Lined Thread Brass Insert Mipt x Socket M1 — - — - ------ IN Part Number Size L M1 N Approx. Wt. (Lbs.) 4236-007 3/4 2-17/32 1-13/32 13/16 .26 4236-010 1 2-15/16 1-23/32 29/32 .43 4236-012 1-1/4 3-1/8 2-3/32 31 /32 .66 4236-015 1-1/2 3-9/32 2-11 /32 31 /32 .80 4236-020 2 3-7/16 2-27/32 31 /32 1.00 ADJUSTABLE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Socket x SR Fipt Q N Body �L Width Part Number Size L N Q Body Width Approx. Wt. (Lbs.) Min Max Min Max 42001SR 3/41/2 6-9/32 8 4-7/16 6-1/4 1-7/16 2-3/16 .66 42011SR 1x1/2 6-13/32 8 4-1/2 6-1/8 1-7/16 2-1/8 .68 ADJUSTABLE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Fipt PIPE Q L.D. I 1= N Body ILL Width L N Part Number Size Q Body Width Approx. Wt. (Lbs.) Min Max Min Max 42004SR 3/4x1/2 5-1/32 6-5/16 3-3/16 4-15/32 1-5/16 2-1/8 .36 42014SR 1x1/2 6-7/16 8-1/8 4-7/16 6-1/4 1-7/16 2-3/16 .67 MADE IN THE U.S.A. 20 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS REDUCER BUSHING Flush Style Spigot x Socket PIPE O.D. L N L Part Number Size L N Approx. Wt. (Lbs.) 4237-131 1 x3/4 1-1/4 1 /4 .04 4237-167 1-1 /4x3/4 1-7/16 7/16 .10 4237-168 1-1/41 1-13/32 9/32 .06 4237-210 1-1/20/4 1-5/8 5/8 .19 4237-211 1-1/2xl 1-17/32 13/32 .13 4237-212 1-1/2xl-1/4 1-9/16 5/16 .07 4237-248 20/4 1-29/32 29/32 .28 4237-249 2x1 1-23/32 9/16 .23 4237-250 2x1-1/4 1-11/16 7/16 .21 4237-251 2x1-1 /2 1-11 /16 5/16 .15 4237-290 2-1/2xl-1/4 2-5/32 7/8 .41 4237-291 2-1/2xl-1/2 2-5/32 3/4 .39 4237-292 2-1 /2x2 2-9/32 3/4 .28 4237-338 3x2 2-7/32 11/16 .63 4237-339 3x2-1 /2 1 2-5/16 1 1 /4 1 .42 TRANSITION BUSHING IPS Spigot x CTS Socket PIPE O.D. 1 N �L� Part Number Size L N Approx. Wt. (Lbs.) 4240-101 3/4xl/2 1 1-1/8 5/8 .03 4240-130 1 x1 /2 11-1/4 23/32 .05 CAP Socket M W Part Number Size M W Approx. Wt. (Lbs.) 4247-007 3/4 1-5/16 1-5/16 .04 4247-010 1 1-5/8 1-9/16 .06 4247-012 1-1/4 2-3/32 1-27/32 .13 4247-015 1-1/2 2-11 /32 2 .17 4247-020 2 2-27/32 2-9/32 .39 4247-025 2-1/2 3-17/32 2-5/8 .50 4247-030 3 4-3/8 3 .92 21 SPEARS° MANUFACTURING COMPANY FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS El TEST PLUG - 0-ring Sealed Mipt - For Pressure Testing Only, Not For use with Z4235 Series Adapters FjL� M1 - - - - -- M 1/2-14 NPT Part Number Size L M M1 Approx. Wt. (Lbs.) FTP-005 1/2 1-27/32 1-15/16 1-7/32 .03 TEST PLUG for TorqueSafeTM Gasket Sealed Head Adapters Mipt - For Pressure Testing Only. Use ONLY with Gasket Sealed Head Adapters M1 M 1/2 14 NPT Part Number Size L M M1 Approx. Wt. (Lbs.) FTP-005GS 1/2 1-25/32 2-1/32 1-1/4 .05 TEST PLUG (PVC White) Not UL Listed; For Pressure Testing Only, Mipt L ;I Part Number Size L Approx. Wt. (Lbs.) 4250-005 1/2 27/32 .02 MADE IN THE U.S.A. 22 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS FLANGE - ONE PIECE 4 Bolt Holes, 175 psi Socket M �F-R �= I NJ BOLT CIRCLE DIA. MAX O.D. No. of Bolt Min. Bolt Max. Approx. Wt. Part Number Size L M N R Bolt Circle Bolt Size O.D. (Lbs.) Holes Dia. Len th 4251-007 3/4 1-5/32 1-1/2 1/8 17/32 4 2-3/4 1/2 2 3-29/32 .31 4251-010 1 1-5/16 1-13/16 1/8 11/16 4 3-1/8 1/2 2-1/4 4-9/32 .35 4251-012 1-1/4 1-13/32 2-7/32 5/32 11/16 4 3-1/2 1/2 2-1/4 4-5/8 .44 4251-015 1-1/2 1-19/32 2-1/2 3/16 23/32 4 3-27/32 1/2 2-1/2 5-1/16 .61 4251-020 2 1-27/32 3 5/16 27/32 4 4-3/4 5/8 3 5-31/32 .95 4251-025 1 2-1/2 1 2-7/32 3-1/2 1 7/16 1-1/32 4 1 5-1/2 1 5/8 3-1/4 1 7 1 1.50 BLIND FLANGE 4 Bolt Holes, 175 psi LR BOLT CIRCLE DIA. ►i MAX O.D. - Bolt No. of Bolt Min. Bolt Part Number Size R Bolt Size Max. O.D. Approx. Wt. (Lbs.) Circle Dia. Holes Length 4253-007 3/4 17/32 2-3/4 4 1/2 2 3-27/32 .30 4253-010 1 23/32 3-1/8 4 1/2 2-1/4 4-1/4 .35 4253-012 1-1/4 21/32 3-1/2 4 1/2 2-1/4 4-5/8 .40 4253-015 1-1/2 23/32 3-27/32 4 1/2 2-1/2 5-1/16 .52 4253-020 2 27/32 4-3/4 4 5/8 3 5-31132 .86 4253-025 1 2-1/2 1-1/32 1 5-1/2 1 4 5/8 1 3-1/4 1 6-15/16 1 1.70 4253-030 1 3 1 1-5/16 1 6 1 4 1 5/8 1 3-1/4 1 7-5/8 1 1.72 FLANGE - TWO PIECE Van Stone Style, 4 Bolt Holes, 175 psi Socket M } 1 iR+ i I i N-# BOLT CIRCLE DIA. �I MAX O.D. Bolt Circle No. of Bolt Min. Bolt Part Number Size L M N R Dia. Holes Bolt Size Length Max. O.D. Approx. Wt. (Lbs.) 4254-030 3 2-1/8 1 4-1/4 1 9/32 1 1-1/32 6 4 1 5/8 1 3-1/4 1 7-15/32 1 1.75 23 SPEARS° MANUFACTURING COMPANY FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS El FLANGE - TWO PIECE Van Stone Style, 4 Bolt Holes, 175 psi PIPE O.D. 11- Spigot N L E R i�BOLT CIRCLE6DIA-0-1 MAX O.D. Bolt No. of Bolt Min. Bolt Approx. Wt. Part Number Size L N R Bolt Size Max. O.D. Circle Dia. Holes Length (Lbs.) 4256-007 3/4 1-15/16 13/16 17/32 2-3/4 4 1/2 2 3-27/32 .30 4256-010 1 2-7/32 1-1/32 11/16 3-1/8 4 1/2 2-1/4 4-1/4 .41 4256-012 1-1/4 2-3/8 1 11/16 3-1/2 4 1/2 2-1/4 4-5/8 .50 4256-015 1-1/2 2-7/16 1-3/32 23/32 3-7/8 4 1/2 2-1/2 4-31/32 .65 4256-020 2 2-3/4 1-5/32 25/32 4-3/4 4 5/8 3 5-15/16 1.00 4256-025 2-1/2 3-1/16 1-9/32 1-1/32 5-1/2 4 5/8 3-1/4 6-15/16 1.62 4256-030 3 3-3/8 1-13/32 1-1/32 6 4 5/8 3-1/4 7-9/16 1.76 TRANSITION UNION Brass Thread Insert Style Socket x Fipt 175 psi NUT M O.D. L L N Part Number Size L M N Nut O.D. Approx. Wt. (Lbs.) 4259-010BR 1 2-13/16 1-7/8 1-1/32 2-7/8 .52 4259-012BR 1-1/4 3 2-3/16 1-1/8 3-9/32 .98 4259-015BR 1-1/2 3-3/4 2-1/2 1-9/16 3-17/32 .93 4259-020BR 2 3-5/8 2-7/8 1-1/4 4-5/16 1.64 Not intended to convey or dispense water for human consumption through drinking or cooking UNION Socket x Socket r175 psi NUT M O.D. 1 N L Part Number Size L M N Nut O.D. Approx. Wt. (Lbs.) 4257-007 3/4 2-3/8 1-17/32 3/8 2-1/2 .38 4257-010 1 2-9/16 1-27/32 3/8 2-7/8 .41 4257-012 1-1/4 2-27/32 2-7/32 11/32 3-5/16 .52 4257-015 1-1/2 3-1/8 2-1/2 3/8 3-17/32 .63 4257-020 2 3-5/8 3-1/32 9/16 4-3/16 1.09 MADE IN THE U.S.A. 24 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS SofforqueTIM SR FEMALE SPIGOT SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Spigot x SR Fipt With Elastomer Seal - Use NO Thread Sealant PIPE M1 O.D. N L Part Number Size L M1 N Approx. Wt. (Lbs.) F74278-101GSR 314112 2-1/4 1-3/8 1 .11 SHORT REPAIR COUPLING Spigot x Socket 175 psi L2 ' L1— L3 *—S I Part Number Size L1 L2 L3 M S Approx. Wt. (Lbs.) SH118-07CO 3/4 4-13/16 5-17/32 3/4 1-3/4 2-3/16 .31 SH118-1000 1 4-3/4 5-5/8 31/32 2-1/16 2-5/32 .40 GripLocTm REPAIR COUPLING — LEAD FREE w/EPDM 0-Ring Seals WARNING: DO NOT INSERT FINGERS. 175 psi Maximum Pressure @ 150°F Part Number Size L L1 L2 M S Approx. Wt. Lbs. SG118-1000 1 1-17/32 7-17/32 4-1/4 2-1/4 2-27/32 .73 25 SPEARS" MANUFACTURING COMPANY FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS FlameGuard° CPVC Drain & Swing Check Valves for NFPA 13D Applications Only El Application: FlameGuard° CPVC Orange Swing Check Valves and PVC/CPVC True Union Drain Valves are for use in configuring CPVC Fire Sprinkler System connection to water supply (riser/drain assembly) in NFPA 13D installations only. These valves are not UL Listed and NOT for use in any other locations within the fire sprinkler system. TRUE UNION INDUSTRIAL DRAIN VALVES CPVC Gray Valve with CPVC Orange End Connector Socket x Socket �E� I D 1 A B C Part Number Size A B c D E 1822-007CFG 3/4 2-1/4 2-3/4 4-3/4 2-7/8 3-3/8 1822-010CFG 1 2-1/2 2-7/8 5-1/8 3-1/8 3-7/16 1822-012CFG 1-1/4 3-1/16 3-1/4 5-3/4 3-5/8 3-7/8 1822-015CFG 1-1/2 3-1/2 3-1/2 6-1/4 4 4-3/16 1822-020CFG 2 4-1/4 4-3/4 7-3/4 4-1/2 5-1/8 Not UL Listed TRUE UNION DRAIN VALVES PVC Valve with CPVC End Connector Socket x Socket WED A — — l C— Part Number Size A B c D E 3622-007FG 3/4 2-1/4 2-3/4 4-3/4 2 3 3622-010FG 1 2-1/2 2-7/8 5-1/8 2-5/16 3-7/16 Not UL Listed MADE IN THE U.S.A. 26 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS COMPACT 2000 DRAIN VALVE = E Socket x Socket wl A — -- �B� c Part Number Size A B C D E 6622-007C0 3/4 1-13/16 1-1/2 3-9/16 2 3 6622-01000 1 2-1 /16 1-3/4 4 2-5/16 3-7/16 Not UL Listed CPVC SWING CHECK VALVES Socket x Socket B � C Part Number Size A B C D Approx. Wt. (Lbs) S1520-1000 1 1-11/16 2-5/16 4-9/16 2-5/8 .33 S1520-12C0 1-1/4 2-1/16 2-15/16 5-1/2 3-3/8 .42 S1520-15C 1 1-1/2 1 2-7/16 13 15-5/8 13-3/8 1.89 Not UL Listed CPVC SPECIAL REINFORCED THREAD INLET SWING CHECK VALVES SR Fipt x Socket A W1-O— — — D 1 14 c 0- Part Number Size A B C D Approx. Wt. (Lbs) S1520-10FSRSCO 1 1-11/16 2-15/16 4-9/16 2-5/8 .33 S1520-12FSRSCO 1-1/4 2-1/16 3-5/8 5-1/2 3-3/8 .42 S1520-15FSRSCO 1-1/2 2-7/16 3-11/16 5-5/8 3-3/8 .89 Not UL Listed 27 SPEARS° MANUFACTURING COMPANY NOTES NOTES PRODUCT LIMITED LIFETIME WARRANTY El Except as otherwise specified for certain products, mandated by law or herein provided, Spears" Manufacturing Company ("Company') warrants Standard Catalog Products ("Products") which have been directly manufactured by them to be free from defects in material and workmanship for as long as the original intended end user of the Products ("End User") retains ownership and possession of the Products and complies with this Warranty ("Warranty Period"). Each other person or entity acquiring or employing the Products, including buyers, contractors and installers ("Buyer") and End Users ('Buyer/End User") agrees that this Warranty shall be effective only during the Warranty Period so long as the Products are used solely for the normal purposes for which they are intended and in conformance with industry established standards, engineering, installation, operating, and maintenance specifications, recommendations and instructions including explicit instructions by the Company; the Products are properly installed, operated and used, and have not been modified; and all the other terms of this Warranty are complied with. Any violation thereof shall void this Warranty and relieve Company from all obligations arising from this Warranty and the Products. Upon receipt or discovery of any Products that appear questionable or defective each Buyer/End User shall promptly inspect and return any such Prod- uct to the Company at 15853 Olden Street, Sylmar, California 91342, accompanied by a letter stating the nature of any problems. If the Prod- ucts are determined by Company to be defective in materials or workmanship directly provided by Company, Company, at its sole option, may ei- ther repair or replace the defective Products, or reimburse applicable Buyer/End User for the cost of such Products. The applicable Buyer/End User shall bear all applicable shipping costs. THIS SHALL BE BUYERS/END USERS' SOLE REMEDY. EACH BUYER/END USER AGREES THAT COMPANY WILL NOT BE RESPONSIBLE FOR ANY OTHER OBLIGATIONS RELATING TO THE PRODUCTS, INCLUDING ANY OTH- ER MATERIALS OR LABOR COSTS, LOSS OF USE OR ANY OTHER ITEM OR FOR ANY DELAYS IN COMPLYING WITH THIS WARRANTY BEYOND COMPANY'S REASONABLE CONTROL. COMPANY SHALL NOT BE LIABLE FOR, DOES NOT ASSUME, AND EXPRESSLY DISCLAIMS, ANY LIABILITY, RESPONSIBILITY AND DAMAGES: DUE TO ANY BUYER/END USER'S FAILURE TO COMPLY WITH THIS WARRANTY, INCLUDING IMPROPER INSTALLATION, USE OR OPERATION; USE WITH PRODUCTS FROM OTHER MANUFACTURERS THAT DO NOT MEET ASTM OR OTHER APPLICABLE PRODUCT STANDARDS; IMPROPER CONTROL OF SYSTEM HYDRAULICS, IMPROPER WINTERIZATION PROCEDURES, IMPROPER VOLTAGE SUPPLY, CON- TACT WITH INCOMPATIBLE MATERIALS OR CHEMICALS, EXCAVATION/DIGGING, EXCESSIVE WEIGHT, AND VANDALISM; DUE TO REASONABLE WEARAND TEARAND DUE TOANYACTS OF NATURE, INCLUDING LIGHTNING, EARTHQUAKES, GROUND MOVEMENT, FROST HEAVE, OR FLOODS. COMPANY EXTENDS ONLYTHIS WARRANTYAND EXPLICITLY DISCLAIMSALL OTHER WARRANTIES, WHETHER IMPLIED OR OTHERWISE EXPRESSED, WHETHER ORAL, STATUTORY OR OTHERWISE, INCLUDING ANY IMPLIED WARRANTIES OR AFFIRMATIONS FOR SUITABILITY, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. NO AFFIRMATION BY COMPANY OR ANY OF ITS REPRESENTATIVES, BY WORDS, CONDUCT OR OTHERWISE, SHALL CONSTITUTE A WARRANTY. THIS WARRANTY MAY NOT BE TRANSFERRED, EXTENDED, ALTERED OR OTHERWISE MODIFIED IN ANY MANNER, EXCEPT BY WRITTEN AGREEMENT SIGNED BY COMPANY. BY ITS ACCEPTANCE OF THE PRODUCTS, EACH BUYER/END USER EXPRESSLY WAIVES ALL OTHER LIABILITY OR OBLIGATION OF ANY KIND OR CHARACTER OF COMPANY, INCLUDING LIABILITY PREDICATED UPON CONTRACT, TORT, STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE GROUNDS, AND ALL, IF ANY, DAMAGES AND LOSSES AS A RESULT THEREOF, INCLUDING ALL, IF ANY, COMPENSATORY, GENERAL, SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR PUNITIVE DAMAGES. WITH RESPECT TO SUCH WAIVERS, EACH BUYER/END USER EXPLICITLY WAIVES CALIFORNIA CIVIL CODE §1542 WHICH STATES "A GENERAL RELEASE DOES NOT EXTEND TO CLAIMS WHICH THE CREDITOR DOES NOT KNOW OR SUSPECT TO EXIST IN HIS FAVOR AT THE TIME OF EXECUTING THIS RELEASE, WHICH IF KNOWN BY HIM MUST HAVE MATERIALLY ADVERSELY AFFECTED HIS SETTLEMENT WITH DEBTOR" AND ALL OTHER SIMILAR STATU- TORY, COMMON AND CASE LAW RIGHTS, DEFENSES AND LIMITATIONS. Having previously independently inspected the Products, or a sample, as fully as desired, or having the opportunity to and having not done so, upon acceptance of delivery of the Products, and except as otherwise herein explicitly provided, each Buyer/End User by acceptance or use of the Products accepts them in their "AS IS" and "WITH ALL FAULTS" condition without any other warranty, expressed, implied or otherwise, and accepts and assumes the entire risk and cost of all servicing, remediation and consequences thereof. This Warranty shall be governed by California law and any unenforceable provisions severed without affecting the remaining provisions. As used herein, "including" includes "without limitation." Spears° Quality Policy It is the policy and objective of Spears® Manufacturing Company to produce a superior quality product suitable for its intended use, with regard to functionality, structural integrity and conformance to established industry standards and practices. It is the commitment of this Company to do so in a manner which provides consistency of product quality, optimum availability, and superior customer service, while maintaining efficiency of operations and profitability necessary to perpetuate product improvement and customer satisfaction. Furthermore, it is recognized that the attainment of these objectives is the responsibility of all Company operations and personnel according to their respective functions. The information contained in this publication is based on current information and product design at the time of publication and is subject to change without notification. Our ongoing commitment to product improvement may result in some variations. No representations, guarantees or warranties of any kind are made as to its accuracy, suitability for particular application or results to be obtained therefrom. For information not contained herein, please contact Spears® Technical Services Department [West Coast: (818) 364-1611— East Coast: (678) 985-1263]. Reproduction of this publication in whole or in part is prohibited without the authorized consent of Spears® Manufacturing Company, Sylmar, California. © Copyright 2014 Spears® Manufacturing Company. All Rights Reserved. Printed in the United States of America. SPEARS° MANUFACTURING COMPANY Corporate Office SPEARS 15853 Olden Street • Sylmar, CA 91342 PO Box 9203 • Sylmar, CA 91392 1] (818) 364-1611 • http://www.spearsmfg.com © Copyright 2015 Spears® Manufacturing Company. All Rights Reserved. Printed in the United States of America 11/15. FG-4-1115 Pipe Clamps v '6. m n iv 3 N� TOLCOT" Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe Size Range: Available in 3/4" (20mm) and 1" (25mm) pipe sizes Material: Pre -Galvanized Steel Function: Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 11/2" (20mm) x 11/2" (20mm) from mounting surface. This design will ease installation by eliminating the need for wood block extension and allow retro-fit attachment of hanger to sprinkler pipe. Features: • Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not required to be bent for listed installation. • Offset edge eliminates abrasion. • Attaches easily to wood structure with two special #10 x 1 " hex head self -threading screws furnished with product. • Can be used as a single offset hanger by aligning "dimples" with top of mounting surface and utilizing two fasteners in two of the three holes provided. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish: Pre -Galvanized Order By: Part number and pipe size. Patent Pending Pipe Size Approx. Wt./100 Part No. in. (mm) lbs. (kg) 29-3/4 3/4" (20) 17.0 (7.7) 29-1 1" (25) 18.6 (8.4) Double Offset Single Offset (38.1mm) �O O CC. 0 7 on o C (38.1mm) I:@" LISTED ll (38.1mm) I---------- , 1.5" (38.1mm) Install using a rechargeable electric drill fitted with a 5/16" (7.9mm) socket attachment with the special hex head self -tapping screws provided. Install screws until they bottom out. Pipe can be "snapped" into hanger before or after installation of the screws to the mounting surface. "Thumb tab" may be bent up to provide additional protection to the pipe, but is not required for performance of the hanger / restrainer function. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 103 B-Line series Pipe Hangers & Supports Fig. 28 - "Stand -Off" Hanger & Restrainer for CPVC Plastic Pipe Size Range — 3/4" through 2" Material — Carbon Steel, Pre -Galvanized Function — Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off" design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces. • Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation. • The "Stand -Off" design eliminates the need for wood block extension. • Can be installed on horizontal or vertical piping regardless of mounting surface orientation. • Attaches easily to wood structure with two hex head self -threading screws furnished with product. • Installs easily using rechargeable electrical driver with 5/16" extension socket eliminating impact tool damage to pipe. • Attaches easily to steel, minimum 18 gauge with (2) 1/4" x 1 " tek type self drilling tapping screws. • UL Listed as a hanger and a restrainer for fire sprinkler piping. Approvals — Underwriters' Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1 " tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satis- fies the UL vertical restraint requirement where needed. UL Listed as a hanger and ver- tical restraint when installed on 3/8" composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper installed screw when used as a hanger only. Order by — Figure number and pipe size. Pat. # 7,455,268, Pat. # 7,832,248 F10.2i9 [1j REgUIRM _ HIGH SIDE OF HANGER FIG Z79 (2) REOIIIR W FLANGCR APPLICATION HANGER 8. RESTRAkNT APPLICATION j F0m FI020 FIQffi FN3.48 ran C @US LISTED O Dimensions • Weights Pipe Approx. Size A B C Wt. 3/4 31/32 2 31/2 .180 1 35/16 23/1 6 31/2 .210 11/4 35/8 23/8 31/2 .225 11/2 4 21/2 31/2 .310 2 41/2 211/16 35/8 .340 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 m CUSTOMER SERVICE • 800.786.5266 www.tolco.com CAL FIRE - RIVERSIDE UNIT RIVERSIDE COUNTY FIRE DEPARTMENT OFFICE OF THE FIRE MARSHAL — LA QUINTA CALIFORNIA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org September 21, 2020 JC Fire Protection 81705 De Oro Ave Indio, CA 92201 Re: Residential Fire Sprinkler Plan Review — STEMMER RESIDENCE FSS2020-0112 / 52975 AVENIDA OBREGON, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist i RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARDI �i�v THIS CARD IS TO REMAIN ON SITE AT ALL TIMES.—cnuroRNZA— INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 52975 AVENIDA OBREGON PERMIT#: FSS2020-0112 AT ED: 9/21/2020 DESCRIPTION: STEMMER RESIDENCE CONTRACTOR: JC FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre -pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final IF Deluge/pre-action SPRINKLER U.G. Final EF Thrust block pre -pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final IF Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors' test Hood/duct extinguishing High pile storage High pile rack storage In -rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final IF Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final e F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final e F FIRE ALARM KNOX SYSTEM Rough -wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final F' Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE- 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE -INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131