Loading...
FSS2020-0128Description: LA QUINTA PET HOSPITAL / FIRE SPRINKLER / T.I. Type: FIRE SPRINKLER (WEB) Subtype: TENANT IMPROVEMENT Status: FINALED Applied: 9/30/2020 AMA Approved: 10/19/2020 KHET Parcel No: 643220025 Site Address: 78555 HIGHWAY 111 STE 200 LA QUINTA,CA 92253 Subdivision: PM 29791 Block: Lot: 1 Issued: 10/19/2020 KHET Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 11/3/2020 KHET Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Relocating 4 heads, adding 1 head. 0 �\ `.00� 19 i Applied to Approved Approved to Issued Issued to Finaled 15 I ill I ill IN • • Ll lei• 7CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES Sent email to Jonathan Stahl @ Shasta Fire Protection to confirm their involvement and clarify the need for official E-MAIL KOHL HETRICK 10/1/2020 10/1/2020 plans to be submitted, reviewed and approved prior to work beginning. APPLICANT RECEIVED AN ERROR ON TRAKIT DURING THE PAYMENT PORTION AND TRIED TO PAY MULTIPLE TIMES. THE MONEY WAS COMING THOURGH BUT THE PERMIT WAS NOT BEING CREATED, WHEN I RECEIVED THE CALL I NOTICED THAT NOTE ARMANDO MAGALLON 9/30/2020 9/30/2020 THE APPLICANT HAD BEEN CHARGED 3 TIMES, I LET HER KNOW WHAT WAS GOING ON AND THAT I WOULD REFUND/VOID 2 OF HER THE OVERCHARGES. 2 OF THE OVERCHARGES HAVE BEEN VOIDED Printed: Thursday, February 23, 2023 3:22:02 PM 1 of 5 WsYsrEMS SHASTA FIRE CALLED AND STATED THEY WOULD BE DOING THE WORK FOR THIS JOB AND ASKED HOW TO SUBMIT PLANS. JOHN PAULUS WAS ADVISED PERMIT WAS ALREADY PULLED AND PAID BY GC AND WE NEED AUTH LETTER FROM TELEPHONE CALL KAYLI ALFORD 10/13/2020 10/13/2020 SHASTA STATING THEY WILL BE HANDLING THE JOB SO THE PERMIT CAN BE PUT IN THEIR NAME SINCE THEY WILL BE DOING THE WORK. LETTER RECEIVED AND ATTACHED. PER KOHL AND ARMANDO OK TO TRANSFER PERMIT TO SHASTA FIRE FROM JA DOLAN. Spoke to Joe Dolan and explained the requirement and process for the deferred Fire Sprinkler TI permit. Further explained the concern about Fire Fees associated with both TELEPHONE CALL KOHL HETRICK 10/1/2020 10/1/2020 the Building and Fire Sprinkler TI permits. Joe advised that they have resourced Shasta Fire Protection to develop plans and submit. CONDITIONS CONDITION DATE DATE DATE CONTACT STATUS REMARKS NOTES TYPE ADDED REQUIRED SATISFIED READY TO ISSUE KAYLI ALFORD 9/30/2020 10/14/2020 COMPLETE LICENSED C16 CONTRACTOR REQUIRED CHECKLIST CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT J A DOLAN GENERAL CONTRACTOR 74794 42ND AVE STE 6 PALM DESERT CA 92260- jadolan@verizon.net INC 7910 BILL TO J A DOLAN GENERAL CONTRACTOR 74794 42ND AVE STE 6 PALM DESERT CA 92260- jadolan@verizon.net INC 7910 CONTRACTOR SHASTA FIRE PROTECTION INC 72120 NORTHSHORE ST THOUSAND CA 92276 jpaulus@shastafire.co #C PALMS m CONTRACTOR J A DOLAN GENERAL CONTRACTOR 74794 42ND AVE STE 6 PALM DESERT CA 92260- jadolan@verizon.net (HISTORY) INC I I 1 1 7910 OWNER JDD 78555 HIGHWAY 111 1 LA QUINTA I CA 1 92253 Printed: Thursday, February 23, 2023 3:22:02 PM 2 of 5 WsYsrEMS CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY FIRE SPRINKLER SYSTEMS - TENANT 101-0000-42420 0 $161.00 $161.00 9/30/20 R62567 WEB6390 CREDIT JOSEPH DOLAN AMA IMPROVEMENT OVER 10 HEADS FIRE SPRINKLER SYSTEMS - TENANT 101-0000-42420 0 $242.00 $242.00 9/30/20 R62567 WEB6390 CREDIT JOSEPH DOLAN AMA IMPROVEMENT OVER 10 HEADS PC Total Paid for FIRE FEES: $403.00 $403.00 RECORDS 101-0000-42416 0 $10.00 $10.00 9/30/20 R62567 WEB6390 CREDIT JOSEPH DOLAN AMA MANAGEMENT FEE Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY 502-0000-43611 0 $5.00 $5.00 9/30/20 R62567 WEB6390 CREDIT JOSEPH DOLAN AMA ENHANCEMENT FEE Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 $418.00 SEQID INSPECTION TYPE INSPECTOR SCHEDULED D CO7DATE RESULT REMARKS NOTES DATE OVERHEAD HYRO KHET 10/19/2020 10/19/2020 APPROVED OVERHEAD ROUGH KHET 10/19/2020 10/19/2020 APPROVED OKAY TO COVER PIPING FIRE FINAL" KHET 10/19/2020 10/19/2020 NOT READY JUST ROUGH WAS READY. OKAY TO COVER ONLY. Printed: Thursday, February 23, 2023 3:22:02 PM 3 of 5 WsYsrEMS FIRE FINAL" I KHET 110/29/2020 110/29/2020 I DISAPPROVE FIRE FINAL" I KHET 1 11/3/2020 1 11/3/2020 1 APPROVED EXISTING HEADS ARE VK102 "STANDARD" PENDANTS. CONTRACTOR INSTALLED 5+ NEW VK302 "QUICK RESPONSE" PENDANTS. CANNOT MIX QR WITH STANDARD. SEE NOTES OBSERVED A FEW ADDITIONAL PAINTED/MUDDED HEADS THAT NEED TO BE REPLACED NO REINSPECTION FEE CHARGE RETURNED STATUS REMARKS REVIEW TYPE REVIEWER SENT DATE DUE DATE NOTES DATE 1ST PERMIT TECH (1 ARMANDO 9/30/2020 10/1/2020 10/1/2020 INCOMPLETE NEED C16 LICENSED CONTRACTOR APPROVAL DAY) MAGALLON AND SUBMITTAL 2ND PERMIT TECH — KAYLI 10/14/2020 10/15/2020 10/14/2020 COMPLETE ETRAKIT (1 DAY) ALFORD KOHL 10/14/2020 10/28/2020 10/19/2020 APPROVED SEE ATTACHMENTS 1ST FIRE (2 WK) HETRICK BOND INFORMATION Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 9/30/2020 ARMANDO MAGALLON RE_ FSS2020-0128 - RE_ FSS2020-0128 - 0 OVERCHARGES.msg OVERCHARGES.msg LQ Pet, Tenant Tenant Improvement Improvement Plans for DOC 9/30/2020 EtrakitContractor Plan for Fire Sprinkler 1 Fire Sprinkler Permit, Permit 9.30.2020.pdf Printed: Thursday, February 23, 2023 3:22:02 PM 4 of 5 WsYsrEMS ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED REVISED T.I. Plan for LQ Pet, Tenant DOC 10/2/2020 EtrakitContractor Fire Sprinkler Permit Improvement Plans for 1 Fire Sprinkler Permit, (Contractor Added) REVISED 10.2.2020.pdf DOC 10/14/2020 EtrakitContractor 20-1342 10-14-20.pdf 1 LA QUINTA PC DOC 10/14/2020 EtrakitContractor APPLICATION 10-14- 1 20.pdf DOC 10/14/2020 EtrakitContractor VIKING MICROFAST SSP 1 K 5.6 VK302.pdf DOC 10/13/2020 KAYLI ALFORD SHASTA SHASTA 0 AUTHORIZATION.pdf AUTHORIZATION.pdf DOC 10/19/2020 KOHL HETRICK FSS2020-0128 - FSS2020-0128 - 1 APPROVED PLANS.pdf APPROVED PLANS.pdf DOC 12/7/2020 KOHL HETRICK FSS2020-0128 - COA FSS2020-0128 - COA 1 AND JOB CARD.pdf AND JOB CARD.pdf Printed: Thursday, February 23, 2023 3:22:02 PM 5 of 5 WsYsrEMS A O 0�1 1101 1 LIGHT —PAN -225SILFT.—ND NOTE: — H-HED ARE NOT IN C---T TE=E` �PllcED .1 E . — T -EELLE. — L,. E TNE DIGTIM T1 FEE -.1 1.7., Er. 1uscvnmEwco,wo 21 LL U 0 1.1 IG —IG 2-11111111111 TIE OLE .6 E —T1111,- I 1-1ILE1H Ec 1. Al. p CL G, —15 LL ——1. a I —I IL 8 1 G1 TD EE PL—D GFF. 09 L o oca cDoc.yo Nw TENANT NWRC—NT srxeoL LEGEND 0 LL 2 1— .0 Q.— GCNE-I-EAFTIN J.A. MILAN CONTRACTOR ()60) 34M905 N P—..: LA QUINTA PET HOSPITAL T.I. t .M:=Em=E="o(949) 554— 00=0 f N—AGT I-=VarNG 71115 HIGHWAY I I I 1LrE 20 VALVE IE— w E -A QUINTA, �IFOMA 4INIP—VE T .o INPE F:IRession .0. (CAj — 1—) 1.1519 1 ILICIONESE CEASEC-161 DINEDEI anJ. F-WS DATE: 10-1 2D . UMENG Tmemr LME F U. E. ND. ul� PURE pnom-Tum, Ul"ig. xE,aml :::::D = IID ITEDINI MUR--... 72120 Northshom Street Sulte, C FILD (76D) k DVB�UM2 •C WILL TprAL4 NOTED Thamemad Palms, California M76 .—m. R� rx Ml}rrHn XTtirM// i 1 44 •IIM rx,.«x rvlllr nr urtwrA, %•r\Iv Arwnnrr Installing Contractor: Shasta Fire Protection, Inc. License# 476633 72120 Northshore Street, Suite C Thousand Palms, CA 92276 (760)404-1350 jstahl@shastafire.com Project: La Quinta Pet Hospital 78555 Hwy 111, Suite 200 La Quinta, CA 92253 d.0 s wAu lciXe -I Will rx Ana l:l'rtf) 1' uv..c11 A 1101'" n rxs lmlw w,.11 IT nI m.M(x "I.I.rh WAII I,) IIAIIM 011 ""Alt 1!IXI IN AMXIYXII �G WAI I WM:I ill [19F WAIT T IXMXIV ❑1 A{1�,O wWIF "I'l l ql ••`) AYX I'll qq G4. pzrr. 0 P-1 JC L, A Cox. WAtI 1 nl NWa Ifl A (Ml wwil(XW WAIT h)R F \ p L (rM( 45 No Tr FG146V66 iv T .f . Page 1 of 1 10/2/2020 Page 1 of 6 ® MICROFAST° QUICK 4 I KjRESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION The Viking MicrofaW Quick Response Pendent Sprinkler VK302 is a small thermo- sensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS c @us cULus Listed: Category VNIV `p" p FM Approved: Class Series 2000 vds VdS Approved: Certificates G414009 and G414010 LPCB LPCB Approved C E CE Certified: Standard EN 12259-1:1999, A3:2006 Certificate of Constancy of Performance 0832-CPR-SO021 4` CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric—) Glass -bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) �Wl_us Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-Cl1000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring -Exposed For ENT Coated Sprinklers: Belleville Spring -Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Form No. F_033314 17.10.05 Rev 17.2 Replaces Form No. F_033314 Rev 17.1 (Replaced wrench 10896W/B with 21475M/B) Page 2 of 6 ® MICROFAST° QUICK 4 I KjRESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Wrenches: A. Standard Wrench: Part No. 21475M/B (available since 2017). B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A %" ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of V diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: A. Six -head capacity: Part No. 01724A (available since 1971) B. Twelve -head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat -sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast° Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Protective Sprinkler Cap Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_033314 17.10.05 Rev 17.2 Page 3 of 6 ® MICROFAST° QUICK 4 I KjRESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion -Resistant Coatings': White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion -resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Sprinkler wrench 13655W/B** for recessed pendent sprinklers ** A 1/2" ratchet is required (not available from Viking) 447774 v Y` Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 17.10.05 Rev 17.2 Page 4 of 6 ® MICROFASTO QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 1 (UL) The Viking Microfast® Quick Response Temperature KEY � Finish Pendent Sprinkler VK302 A1X�Escutcheon (if applicable) Maximum 175 PSI (12 Bar) WWP Base Sprinkler Thread Size Nominal Overall Listings and Approvals3 Part SIN Style K-Factor Length (Refer also to Design Criteria.) Number NPT I BSP U.S. metric2 Inches mm cULus' VdS LPCB 7 Q 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X Al A1Z, B1Y D1Z, C1Y 19780 VK302 Pendent 1/2" 5.6 80.6 2-1/4 58 D3 21354 VK302 Pendent -- 15 mm 5.6 80.6 2-1/4 58 D3 NOTICEOffice) 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X 18021 VK302 Pendent 1/2' 15 mm 1 5.6 1 80.6 2-1/4 58 A1X, B1Y Al A1X, B1Y D1X, C1Y8 D1X, C1Y9 Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135 -F (57 -C), 155 -F (68 -C), 175 -F 1 - Brass, Chrome, White X - Standard surface -mounted escutcheon or the (79 -C), 200 -F (93 -C), 286 -F (141 -C) Polyester',', Black Polyes- Viking Micromati& Model E-1 Recessed Escutcheon B - 135 -F (57 -C), 155 -F (68 -C), 175 -F ter56 Y - Standard surface -mounted escutcheon or the (79 °C), and 200 °F (93 °C) 2 - ENT' Viking Microfast® Model F-1 Adjustable Escutcheon, or recessed with the Viking Micro- C - 155 °F (68 °C), 175 °F (79 °C), and 3 - Chrome mati& Model E-1, E-2, or E-3 Recessed Escutcheon 200 -F (93 -C) Z - Standard surface -mounted escutcheon or the D - 155 -F (68 -C), 175 -F (79 -C), 200 -F Viking Microfast Model F-1 Adjustable Escutcheon (93 -C), 286 -F (141 -C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. z Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. ° Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. s cULus Listed as corrosion -resistant. s Other colors are available on request with the same Listings and Approvals as the standard colors. 7 CE Certified, Standard EN 12259-1, EC -certificate of conformity 0832-CPD-2001. $ CE Certified, Standard EN 12259-1, EC -certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. s MED Certified, Standard EN 12259-1, EC -certificates of conformity 0832-MED-1003 and 0832-MED-1008. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast° Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT. Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan- dards, whenever applicable. Form No. F_033314 17.10.05 Rev 17.2 Page 5 of 6 ® MICROFAST° QUICK RESPONSE PENDENT SN4 I KJ PRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY The Viking Microfast° Quick Response Finish Pendent Sprinkler VK302 A1XFEscutcheon (if applicable); Maximum 175 PSI (12 Bar) WWP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' Number' SIN Style (Refer also to Design Criteria.) NPT BSP U.S. metric' Inches mm 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 1 58 A1Z, B1Y, D2X, C2 NOTICE.. Office) 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 1 A1Z, B1Y Approved Escutcheons Approved Temperature Ratings X - Standard surface -mounted escutcheon or the A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F Viking Micromatic® Model E-1 Recessed (93 °C), 286 °F (141 °C) Approved Finishes Escutcheon B - 135 °F (57 -C), 155 °F (68 °C), 175 °F (79 °C), and 1 -Brass, Chrome, White Polyester', Y - Standard surface -mounted escutcheon or the 200 °F (93 °C) and Black Polyester^ Viking Microfast® Model F-1 Adjustable Escutcheon, C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 2 - ENT5 or recessed with the Viking Micromatic® Model E-1 °F (141 °C) or E-2 Recessed Escutcheon D - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) Z - Standard surface -mounted escutcheon or the Viking Microfast® Model F-1 Adjustable Escutcheon Footnotes ' Base part number shown. For complete part number, refer to Viking's current price schedule. Z Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Other approvals may be in process. 4 Other colors are available on request with the same Approvals as the standard colors. 5 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: The Viking Microfast° Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non -storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT. Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 17.10.05 Rev 17.2 Page 6 of 6 ® MICROFAST° QUICK N4 I KJRESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1 /2" (15 mm) NPT` 2-1/4" x� (57 mm) Installed with a standard 1/8" surface -mounted escutcheon Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum 2-1/8" (54 mm) T 1-1 /2" 2" (38 mm) (51 mm) Min. Max. Installed with a Microfast Note: At maximum, adapter Model F-1 Adjustable is exposed 1/2" (13 mm) Escutcheon from face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon It 2-1/8"� (54 mm) r' I 1-3/4" (45 mm) Max. Installed with a Model E-1 Recessed Escutcheon A „1 1-1 /8" (29 mm) Min. It 2-1/8" (54 mm) 1 2,,,, (51 mm) Max. -44W Installed with a Model E-2 Thread -on Recessed Escutcheon Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum f � 1-1 /8" (29 mm) Min. Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 17.10.05 Rev 17.2 Replaces Form No. F_033314 Rev 17.1 (Replaced wrench 10896W/B with 21475M/B) Kayli Alford From: John Paulus <jpaulus@shastafire.com> Sent: Tuesday, October 13, 2020 10:30 AM To: Kayli Alford Subject: LA QUINTA PET HOSPITAL EXTERNAL: This message originated outside of the City of La Quinta. Please use proper judgement and caution when opening attachments, clicking links or responding to requests for information. Kaylee, Shasta Fire Protection will be doing the tenant improvement fire sprinkler design and installation for the La Quinta Pet Hospital at 78555 Highway 111 ( Ste 200 ) La Quinta. Thank you. JOHN PAULUS - ENGINEERING DEPT. SHASTA FIRE PROTECTION, INC. 72120 NORTHSHORE STREET SUITE C THOUSAND PALMS, CALIFORNIA 92276 PHONE: (760) 404-1350 FAX: (760) 404-1354 jpaulus@shastafire.com CAL FIRE - RIVERSIDE UNIT RIVERSIDE COUNTY FIRE DEPARTMENT OFFICE OF THE FIRE MARSHAL — LA QUINTA CALIFORNIA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org October 19, 2020 Shasta Fire Protection 72120 Northshore St #C Thousand Palms, CA 92276 Re: TI Fire Sprinkler Plan Review — LA QUINTA PET HOSPITAL FSS2020-0128 — 78555 HIGHWAY 111 #200, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. The following inspections/tests are required to be witnessed by the Office of the Fire Marshal staff: 1) Overhead Rough: All installed/relocated piping must be visible. 2) Final inspection: All trim is in place, 5-Year certification is current. New/added heads shall be included in the spare head box compliment. *Water -flow signal test may be performed during the Final Inspection. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD aCCv a THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. - CALIFORNIA - INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 78555 HIGHWAY 111 #200 PERMIT#: FSS2020-0128 DATE SUED: 10/19/2020 DESCRIPTION: LQ PET HOSPITAL — TI CONTRACTOR: SHASTA FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre -pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final IF Deluge/pre-action SPRINKLER U.G. Final I Thrust block pre -pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final IF Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final IF Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors' test Hood/duct extinguishing High pile storage High pile rack storage In -rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final IF Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final e F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final e F FIRE ALARM KNOX SYSTEM Rough -wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final IF Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: ""WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE- 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE -INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 CALIFORNIA DESIGN & DEVELOPMENT DEPARTMENT 78-495 Calle Tampico La Quinta, California 92253 (760) 777-7125 / FAX (760) 777-7011 FIRE REVIEW APPLICATION ❑ NEW B TENANT IMPROVEMENT PERMIT NO. PROJECT INFORMATION (Please Print) Project Name: LA QUINTA PET HOSPITAL T.I. Sign: DATE PAID Site Address: 78555 HIGHWAY 111 Print: City & Zip: LA QUINTA Project Description: • Pursuant to a Cooperative Agreement to Provide Fire Services, the Riverside County Fire Department serves as the City's fire department, and the County designee serves as the City's fire chief. Applicant recognizes this contracted arrangement and shall comply with County Fire Department directions. APPLICANT/CONTACT INFORMATION CONTRACTOR INFORMATION: Iiiii! Same as Applicant info Applicant Name: SHASTA FIRE PROTECTION Contractor #: 476633 Contact Person: Jonathan Stahl Contact Person: Jonathan Stahl Mailing Address: 72120 NORTHSHORE ST (C) Mailing Address: 72120 NORTHSHORE ST (C) City & Zip: THOUSAND PALMS 92276 City & Zip: THOUSAND PALMS Phone Number: 760-404-1350 Fax 760-404-1354 Phone Number: 760-404-1350 Fax 760-404-1354 Finai,. jstahl@shastafire.com Fmcril- istahl@shastafire.com A. APPLICATION TYPE FIRE SPRINKLER SYSTEM STORAGE TANKS ❑ NEW COMMERCIAL/INDUSTRIAL ------------ ❑ DISPENSERS ONLY HOURLY@161/HR ❑ 0-35,000 SQ FT $670 ❑ ABOVE GROUND HOURLY@161/HR ❑ 35,001-75,000 SQ FT $791 SUPRESSION SYSTEM ❑75,001-120,000 SQ FT $992 ❑ HOOD & DUCT $418 ❑ 120,001 AND UP $1234 ❑ SPRAY BOOTH HOURLY@161/HR p TENANT IMPROVEMENTS - FIRE SPRINKLER $418 ❑ OTHER SUPRESSION SYSTEM HOURLY@161/HR ❑ RESIDENTIAL Sprinkler Systems ____________ ❑ HAZMAT HOURLY@161/HR ❑ 1-50 SPRINKLER HEADS $418 MISC ❑ 51-100 SPRINKLER HEADS $498 ❑ HAZMAT HOURLY@161/HR ❑ OVER 100 SPRINKLER HEADS $579 ❑ HIGH PILE RACK STORAGE HOURLY@161/HR ❑ RESIDENTIAL - (EA) ADDITIONAL $176 ❑ PRIVATE FIRE MAINS $901 ❑ MULTI -FAMILY Q OR MORE) $590 ❑ TECHNICAL REPORT RESEARCH HOURLY@161/HR FIRE ALARM SYSTEM ❑ FIRE PUMPS $659 ❑ COMMERCIAL -SPRINKLER MONITORING $418 ❑ STANDPIPE SYSTEMS $579 ❑ COMMERCIAL - FIRE ALARM SYSTEM $1062 ❑ WATER TANKS $418 MASTER PLAN ❑ PYRO $740 ❑ MASTER PLAN HOURLY@161/HR ❑ REVISION # HOURLY@161/HR ❑ MASTER PLAN REVISION HOURLY@161/HR ❑ OTHER HOURLY@161/HR Each application type includes a Technology Enhancement Fee of $5 & Records Management Fee of $10 or $21 REVISED 10/2/2019 'For permits billed at an hourly rate, these fees will be added at time of payment.