Loading...
FSS2020-0154ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT J D MECHANICAL FIRE INC 82579 FLEMING WAY SUITE D INDIO CA 92201 (760)775-6220 KATHY@JDMECHANIC AL.CO CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE JULIA AGGREH 1/25/2022 2/25/2022 CONTRACTOR REQUESTED FINAL INSPECTION. PERMIT EXPIRED AS OF 06/05/21 (6 MOS FROM DATE OF LAST APPROVED INSPECTION). ADDED EXTENSION FEE OF $83 AND EXTENDED PERMIT TO 1/26/22 SO CONTRACTOR CAN PAY FEE VIA ETRAKIT. WILL ALSO REQUIRE AN EXTENSION REQUEST LETTER FROM CONTRACTOR. OK TO EXTEND PER KOHL. CONDITIONS Description: WALKER / FIRE SPRINKLERS / BRES2018-0357 Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 11/17/2020 ECON Parcel No: 767700046 Site Address: 81735 DE SOTO AVE LA QUINTA,CA 92253 Approved: 12/7/2020 KHET Subdivision: TR 33076-2 Block: Lot: N Issued: 12/7/2020 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 2/17/2022 LIN Valuation: $21,935.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Friday, February 24, 2023 10:12:39 AM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0154 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL BILL TO JD MECHANICAL FIRE INC.82579 FLEMING WAY SUITE D INDIO CA 92201 (760)775-6220 KATHY@JDMECHANIC AL.CO CONTRACTOR J D MECHANICAL FIRE INC 82579 FLEMING WAY SUITE D INDIO CA 92201 (760)775-6220 KATHY@JDMECHANIC AL.CO OWNER ROTNER GLENN / ANN WALKER TRUST 53005 HUMBOLDT BLVD LA QUINTA CA 92253 (760)775-6220 kathy@jdmechanical.c o INSPECTIONS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE PLAN REVISION SUBMITTALS 101-0000-42420 0 $167.00 $167.00 2/15/22 WEB10716 635415491 28 CREDIT 1020141 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $242.00 $242.00 12/7/20 WEB6918 306286 CREDIT J D MECHANICAL FIRE INC ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $242.00 $242.00 12/7/20 WEB6918 306286 CREDIT J D MECHANICAL FIRE INC ECON FIRE STAFF - PER HOUR 101-0000-42420 1 $83.00 $83.00 1/25/22 WEB10485 635002350 39 CREDIT 1020141 ECON Total Paid for FIRE FEES: $734.00 $734.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 12/7/20 WEB6918 306286 CREDIT J D MECHANICAL FIRE INC ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 12/7/20 WEB6918 306286 CREDIT J D MECHANICAL FIRE INC ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$749.00 $749.00 Printed: Friday, February 24, 2023 10:12:39 AM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0154 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/17/2020 EtrakitContractor 1ST SUBMITTAL FIRE SPRINKLERS 8464 Senju Concealed 4 9 RG23.pdf 1 DOC 11/17/2020 EtrakitContractor 1ST SUBMITTAL HYDRAULIC CALCS AREA 1 RG23.pdf 1 DOC 11/17/2020 EtrakitContractor 1ST SUBMITTAL HYDRAULIC CALCS AREA 2 RG23.pdf 1 BOND INFORMATION SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 2/22/2021 2/22/2021 APPROVED AS-BUILT REQD PRIOR TO FINAL REMOTE VIDEO INSPECTION OVERHEAD HYRO KHET 2/22/2021 2/22/2021 APPROVED REMOTE VIDEO INSPECTION FIRE FINAL**KHET 1/31/2022 1/31/2022 NOT READY No Fee Rough inspection notes identified required revised plans/calcs be provided. Should not have been scheduled. FIRE FINAL**LIN 2/17/2022 2/17/2022 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 11/17/2020 12/3/2020 12/7/2020 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 11/17/2020 11/18/2020 11/19/2020 COMPLETE 2ND FIRE (1 WK)KOHL HETRICK 2/14/2022 2/21/2022 2/15/2022 APPROVED SEE ATTACHMENTS PARENT PROJECTS Printed: Friday, February 24, 2023 10:12:39 AM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0154 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/17/2020 EtrakitContractor 1ST SUBMITTAL PLANS RG 23 FS PLAN.pdf 1 DOC 11/17/2020 EtrakitContractor 1ST SUBMITTAL CONNECTION CHARGE Scan_0038.pdf 1 DOC 2/14/2022 Etrakit Contractor AREA 1.pdf rg23.pdf 1 DOC 2/14/2022 Etrakit Contractor AREA 2.pdf rg23.pdf 1 DOC 2/14/2022 Etrakit Contractor RG 23 AS BUILT.pdf 1 DOC 1/26/2022 JULIA AGGREH Extension Request Ltr FSS2020_0154.pdf Extension Request Ltr FSS2020_0154.pdf 0 DOC 12/7/2020 KOHL HETRICK FSS2020-0154 - COA AND JOB CARD.pdf FSS2020-0154 - COA AND JOB CARD.pdf 1 DOC 12/7/2020 KOHL HETRICK FSS2020-0154 - APPROVED PLANS AND CALCS.pdf FSS2020-0154 - APPROVED PLANS AND CALCS.pdf 1 DOC 2/22/2021 KOHL HETRICK FSS2020-0154 - 2-22- 2021 INSP NOTES (1).pdf FSS2020-0154 - 2-22- 2021 INSP NOTES (1).pdf 1 DOC 2/15/2022 KOHL HETRICK FSS2020-0154 - APPROVED REVISED PLANS AND CALCS.pdf FSS2020-0154 - APPROVED REVISED PLANS AND CALCS.pdf 1 Printed: Friday, February 24, 2023 10:12:39 AM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0154 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs RG 23 Prescott, AZ 86301 Page 1 General Project Data Report General Data Project Title: RG 23 Project File Name: RG 23..fiw Designed By: Chad Ryan Date: 12/14/20 Code Reference:Approving Agency: Client Name:Phone: Address:City, State Zip Code: Company Name: JD Mechanical Representative: Kathy Sloan Company Address: 82579 Fleming Way Ste D City And State: Indio, CA 92201 Phone: 760-775-6220 Building Name: AREA 1 Building Owner: Contact at Building:Phone at Building: Address Of Building: 53005 Humboldt City, State Zip Code: Project Data Description Of Hazard: Residential Sprinkler System Type: Wet Design Area Of Water Application: 512 ft² Maximum Area Per Sprinkler: 256 ft² Default Sprinkler K-Factor: 4.90 K Default Pipe Material: CPVC Inside Hose Stream Allowance: 0.00 gpm Outside Hose Stream Allowance: 0.00 gpm In Rack Sprinkler Allowance: 0.00 gpm Sprinkler Specifications Make: SENJU Model:8464 Size:7/16 Temperature Rating: 162 F F = T RUN / B = ANGLE VALVE Water Supply Test Data Source Of Information: Test Hydrant ID:Date Of Test: Hydrant Elevation: 0 ft Static Pressure: 70.00 psi Test Flow Rate: 1000.00 gpm Test Residual Pressure: 63.00 psi Calculated System Flow Rate: 31.06 gpm Calculated Inflow Residual Pressure: 61.62 psi Available Residual Pressure At System Flow:69.99 psi Calculation Project Data Calculation Mode: Demand HMD Minimum Residual Pressure: 7.05 psi Minimum Desired Flow Density: 0.05 gpm/ft² Number Of Active Nodes: 25 Number Of Active Pipes: 25 Number Of Inactive Pipes: 175 Number Of Active Sprinklers: 2 Number Of Inactive Sprinklers: 0 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs RG 23 Prescott, AZ 86301 Page 2 Fire Sprinkler Output Data Overall Pipe Output Data Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 1 4.90 13.00 13.01 7.05 0.75 13.01 0.09458 0.50 0.331 2 0.00 13.50 0.00 7.16 0.874 13.01 T 3.00 -0.217 CPVC 150 6.96 0 3.50 0.115 3 4.90 13.00 13.05 7.09 0.75 13.05 0.09507 0.50 0.713 4 0.00 13.50 0.00 7.59 0.874 13.05 E 7.00 -0.217 CPVC 150 6.98 0 7.50 0.497 6 0.00 11.50 0.00 14.34 0.75 0.00 0.00000 21.00 0.000 24 0.00 13.50 0.00 13.47 0.874 0.00 F3ET 25.00 0.866 CPVC 150 0.00 0 46.00 0.866 2 0.00 13.50 0.00 7.16 0.75 0.00 0.09458 9.50 1.182 22 0.00 13.50 0.00 8.35 0.874 13.01 T 3.00 0.000 CPVC 150 6.96 0 12.50 1.182 4 0.00 13.50 0.00 7.59 0.75 0.00 0.09507 5.00 0.761 22 0.00 13.50 0.00 8.35 0.874 13.05 T 3.00 0.000 CPVC 150 6.98 0 8.00 0.761 22 0.00 13.50 0.00 8.35 0.75 0.00 0.34188 13.00 5.128 24 0.00 13.50 0.00 13.47 0.874 26.06 2F 2.00 0.000 CPVC 150 13.93 0 15.00 5.128 24 0.00 13.50 0.00 13.47 1.00 26.06 0.11105 20.50 4.053 25 0.00 11.50 0.00 18.39 1.101 26.06 2F2E 16.00 0.866 CPVC 150 8.78 0 36.50 4.919 25 0.00 11.50 0.00 18.39 1.00 0.00 0.11105 21.00 4.664 26 0.00 13.50 0.00 22.19 1.101 26.06 2F2ET 21.00 -0.866 CPVC 150 8.78 0 42.00 3.798 26 0.00 13.50 0.00 22.19 1.00 12.36 0.02795 63.00 2.096 28 0.00 13.50 0.00 24.29 1.101 12.36 7FT 12.00 0.000 CPVC 150 4.17 0 75.00 2.096 26 0.00 13.50 0.00 22.19 1.00 13.69 0.03378 49.00 1.959 30 0.00 13.50 0.00 24.15 1.101 13.69 9F 9.00 0.000 CPVC 150 4.61 0 58.00 1.959 28 0.00 13.50 0.00 24.29 1.00 0.00 0.02795 73.50 3.284 32 0.00 11.50 0.00 28.44 1.101 12.36 2F6E 44.00 0.866 CPVC 150 4.17 0 117.50 4.150 30 0.00 13.50 0.00 24.15 1.00 0.00 0.03378 46.60 2.520 34 0.00 11.50 0.00 27.54 1.101 13.69 7F3E 28.00 0.866 CPVC 150 4.61 0 74.60 3.386 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs RG 23 Prescott, AZ 86301 Page 3 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 32 0.00 11.50 0.00 28.44 1.00 0.00 0.02795 25.00 0.922 36 0.00 11.50 0.00 29.36 1.101 12.36 3FT 8.00 0.000 CPVC 150 4.17 0 33.00 0.922 34 0.00 11.50 0.00 27.54 1.00 0.00 0.03378 42.00 1.824 36 0.00 11.50 0.00 29.36 1.101 13.69 7FT 12.00 0.000 CPVC 150 4.61 0 54.00 1.824 36 0.00 11.50 0.00 29.36 1.00 0.00 0.11105 7.50 1.721 100 0.00 11.50 0.00 31.08 1.101 26.06 FE 8.00 0.000 CPVC 150 8.78 0 15.50 1.721 100 0.00 11.50 0.00 31.08 1.00 0.00 0.11105 6.50 1.055 110 0.00 5.00 0.00 34.95 1.101 26.06 3F 3.00 2.815 CPVC 150 8.78 0 9.50 3.870 110 ACV 5.00 34.95 26.02 115 3.00 psi 5.00 37.95 115 0.00 5.00 0.00 37.95 1.00 0.00 0.15733 1.00 1.731 120 0.00 4.00 0.00 40.12 1.025 26.06 EC 10.00 0.433 TYPE L COPPER TUBE 150 10.13 0 11.00 2.164 120 0.00 4.00 0.00 40.12 1.00 0.00 0.15733 1.00 0.472 135 0.00 4.00 5.00 40.59 1.025 26.06 F 2.00 0.000 TYPE L COPPER TUBE 150 10.13 0 3.00 0.472 135 0.00 4.00 5.00 40.59 1.00 5.00 0.21770 30.00 11.756 150 0.00 0.00 0.00 54.08 1.025 31.06 8E 24.00 1.732 TYPE L COPPER TUBE 150 12.08 0 54.00 13.488 150 0.00 0.00 0.00 54.08 1.25 0.00 0.07814 4.00 1.032 160 0.00 -2.00 0.00 55.98 1.265 31.06 3EG 9.20 0.866 TYPE L COPPER TUBE 150 7.93 0 13.20 1.898 160 0.00 -2.00 0.00 55.98 2.00 0.00 0.01343 50.00 0.766 180 0.00 -3.00 0.00 57.17 1.816 31.06 F 7.00 0.433 HDPE SDR-9 150 3.85 0 57.00 1.199 180 0.00 -3.00 0.00 57.17 1.50 0.00 0.03353 2.00 0.335 185 0.00 -3.00 0.00 57.51 1.505 31.06 2E 8.00 0.000 TYPE L COPPER TUBE 150 5.60 0 10.00 0.335 185 Meter -3.00 57.51 31.04 190 2.00 psi -3.00 59.51 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs RG 23 Prescott, AZ 86301 Page 4 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 190 0.00 -3.00 0.00 59.51 2.00 0.00 0.01343 20.00 0.379 200 0.00 -7.00 0.00 61.62 1.816 31.06 B 8.20 1.732 HDPE SDR-9 150 3.85 0 28.20 2.111 Fitting Legend: F = 45 Degree Elbow, E = 90 Degree Elbow, L = Long Turn Elbow, T = Tee or Cross, B = Butterfly Valve, G = Gate Valve, C = Check Valve Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs RG 23 Prescott, AZ 86301 Page 5 Fire Sprinkler Output Summary Hydraulically Most Demanding Sprinkler Node HMD Sprinkler Node Number:1 HMD Actual Residual Pressure:7.05 psi HMD Actual Flow:13.01 gpm Sprinkler Summary Sprinkler System Type:Wet Specified Area Of Application: 512.00 ft² Minimum Desired Density:0.050 gpm/ft² Application Average Density:0.051 gpm/ft² Application Average Area Per Sprinkler: 256.00 ft² Sprinkler Flow:26.06 gpm Average Sprinkler Flow:13.03 gpm Flow Velocity And Imbalance Summary Maximum Flow Velocity ( In Pipe 22 - 24 ) 13.93 ft/sec Maximum Velocity Pressure ( In Pipe 22 - 24 ) 1.31 psi Allowable Maximum Nodal Pressure Imbalance: 0.0100 psi Actual Maximum Nodal Pressure Imbalance: 0.0056 psi Actual Average Nodal Pressure Imbalance: 0.0032 psi Actual Maximum Nodal Flow Imbalance: 0.0323 gpm Actual Average Nodal Flow Imbalance: 0.0044 gpm Overall Network Summary Number Of Unique Pipe Sections: 25 Number Of Flowing Sprinklers:2 Pipe System Water Volume:21.04 gal Sprinkler Flow:26.06 gpm Non-Sprinkler Flow:5.00 gpm Minimum Required Residual Pressure At System Inflow Node:61.62 psi Demand Flow At System Inflow Node: 31.06 gpm Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs RG 23 Prescott, AZ 86301 Page 6 Fire Sprinkler Output Data Hydraulic Supply/Demand Graph Pressure psiFlowrate(x100) gpm 70 6363 0 10 20 30 40 50 60 70 80 90 100 1 2 3 4 5 6 7 8 9 10 Supply Curve Data Static Pressure: 70 psi Test Residual Pressure: 63 psi Test Flow Rate: 1000 gpm Demand Curve Data Calculated Residual Pressure: 61.62 psi Calculated Flow Rate: 31.06 gpm Excess Available Residual Pressure At Calculated Flow: 8.36 psi Pressure Required For First Sprinkler Downstream From Inflow Node To Flow: 0.00 psi Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs RG 23 Prescott, AZ 86301 Page 1 General Project Data Report General Data Project Title: RG 23 Project File Name: RG 23..fiw Designed By: Chad Ryan Date: 12/14/20 Code Reference:Approving Agency: Client Name:Phone: Address:City, State Zip Code: Company Name: JD Mechanical Representative: Kathy Sloan Company Address: 82579 Fleming Way Ste D City And State: Indio, CA 92201 Phone: 760-775-6220 Building Name: AREA 2 Building Owner: Contact at Building:Phone at Building: Address Of Building: 53005 Humboldt City, State Zip Code: Project Data Description Of Hazard: Residential Sprinkler System Type: Wet Design Area Of Water Application: 324 ft² Maximum Area Per Sprinkler: 324 ft² Default Sprinkler K-Factor: 4.90 K Default Pipe Material: CPVC Inside Hose Stream Allowance: 0.00 gpm Outside Hose Stream Allowance: 0.00 gpm In Rack Sprinkler Allowance: 0.00 gpm Sprinkler Specifications Make: SENJU Model:8464 Size:7/16 Temperature Rating: 162 F F = T RUN / B = ANGLE VALVE Water Supply Test Data Source Of Information: Test Hydrant ID:Date Of Test: Hydrant Elevation: 0 ft Static Pressure: 70.00 psi Test Flow Rate: 1000.00 gpm Test Residual Pressure: 63.00 psi Calculated System Flow Rate: 22.01 gpm Calculated Inflow Residual Pressure: 48.79 psi Available Residual Pressure At System Flow:69.99 psi Calculation Project Data Calculation Mode: Demand HMD Minimum Residual Pressure: 12.05 psi Minimum Desired Flow Density: 0.05 gpm/ft² Number Of Active Nodes: 24 Number Of Active Pipes: 24 Number Of Inactive Pipes: 176 Number Of Active Sprinklers: 1 Number Of Inactive Sprinklers: 0 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs RG 23 Prescott, AZ 86301 Page 2 Fire Sprinkler Output Data Overall Pipe Output Data Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 2 0.00 13.50 0.00 19.28 0.75 0.00 0.00000 9.50 0.000 22 0.00 13.50 0.00 19.28 0.874 0.00 T 3.00 0.000 CPVC 150 0.00 0 12.50 0.000 4 0.00 13.50 0.00 19.28 0.75 0.00 0.00000 5.00 0.000 22 0.00 13.50 0.00 19.28 0.874 0.00 T 3.00 0.000 CPVC 150 0.00 0 8.00 0.000 5 4.90 11.00 17.01 12.05 0.75 17.01 0.15529 0.50 1.165 6 0.00 11.50 0.00 13.00 0.874 17.01 E 7.00 -0.217 CPVC 150 9.10 0 7.50 0.948 22 0.00 13.50 0.00 19.28 0.75 0.00 0.00000 13.00 0.000 24 0.00 13.50 0.00 19.28 0.874 0.00 2F 2.00 0.000 CPVC 150 0.00 0 15.00 0.000 6 0.00 11.50 0.00 13.00 0.75 0.00 0.15529 21.00 7.144 24 0.00 13.50 0.00 19.28 0.874 17.01 F3ET 25.00 -0.866 CPVC 150 9.10 0 46.00 6.278 24 0.00 13.50 0.00 19.28 1.00 17.01 0.05044 20.50 1.841 25 0.00 11.50 0.00 21.98 1.101 17.01 2F2E 16.00 0.866 CPVC 150 5.73 0 36.50 2.707 25 0.00 11.50 0.00 21.98 1.00 0.00 0.05044 21.00 2.119 26 0.00 13.50 0.00 23.24 1.101 17.01 2F2ET 21.00 -0.866 CPVC 150 5.73 0 42.00 1.253 26 0.00 13.50 0.00 23.24 1.00 8.07 0.01270 63.00 0.952 28 0.00 13.50 0.00 24.19 1.101 8.07 7FT 12.00 0.000 CPVC 150 2.72 0 75.00 0.952 26 0.00 13.50 0.00 23.24 1.00 8.94 0.01534 49.00 0.890 30 0.00 13.50 0.00 24.13 1.101 8.94 9F 9.00 0.000 CPVC 150 3.01 0 58.00 0.890 28 0.00 13.50 0.00 24.19 1.00 0.00 0.01270 73.50 1.492 32 0.00 11.50 0.00 26.55 1.101 8.07 2F6E 44.00 0.866 CPVC 150 2.72 0 117.50 2.358 30 0.00 13.50 0.00 24.13 1.00 0.00 0.01534 46.60 1.145 34 0.00 11.50 0.00 26.14 1.101 8.94 7F3E 28.00 0.866 CPVC 150 3.01 0 74.60 2.011 32 0.00 11.50 0.00 26.55 1.00 0.00 0.01270 25.00 0.419 36 0.00 11.50 0.00 26.96 1.101 8.07 3FT 8.00 0.000 CPVC 150 2.72 0 33.00 0.419 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs RG 23 Prescott, AZ 86301 Page 3 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 34 0.00 11.50 0.00 26.14 1.00 0.00 0.01534 42.00 0.829 36 0.00 11.50 0.00 26.96 1.101 8.94 7FT 12.00 0.000 CPVC 150 3.01 0 54.00 0.829 36 0.00 11.50 0.00 26.96 1.00 0.00 0.05044 7.50 0.782 100 0.00 11.50 0.00 27.75 1.101 17.01 FE 8.00 0.000 CPVC 150 5.73 0 15.50 0.782 100 0.00 11.50 0.00 27.75 1.00 0.00 0.05044 6.50 0.479 110 0.00 5.00 0.00 31.04 1.101 17.01 3F 3.00 2.815 CPVC 150 5.73 0 9.50 3.294 110 ACV 5.00 31.04 17.01 115 3.00 psi 5.00 34.05 115 0.00 5.00 0.00 34.05 1.00 0.00 0.07146 1.00 0.786 120 0.00 4.00 0.00 35.26 1.025 17.01 EC 10.00 0.433 TYPE L COPPER TUBE 150 6.61 0 11.00 1.219 120 0.00 4.00 0.00 35.26 1.00 0.00 0.07146 1.00 0.214 135 0.00 4.00 5.00 35.48 1.025 17.01 F 2.00 0.000 TYPE L COPPER TUBE 150 6.61 0 3.00 0.214 135 0.00 4.00 5.00 35.48 1.00 5.00 0.11512 30.00 6.217 150 0.00 0.00 0.00 43.43 1.025 22.01 8E 24.00 1.732 TYPE L COPPER TUBE 150 8.56 0 54.00 7.949 150 0.00 0.00 0.00 43.43 1.25 0.00 0.04132 4.00 0.545 160 0.00 -2.00 0.00 44.84 1.265 22.01 3EG 9.20 0.866 TYPE L COPPER TUBE 150 5.62 0 13.20 1.411 160 0.00 -2.00 0.00 44.84 2.00 0.00 0.00710 50.00 0.405 180 0.00 -3.00 0.00 45.68 1.816 22.01 F 7.00 0.433 HDPE SDR-9 150 2.73 0 57.00 0.838 180 0.00 -3.00 0.00 45.68 1.50 0.00 0.01773 2.00 0.177 185 0.00 -3.00 0.00 45.85 1.505 22.01 2E 8.00 0.000 TYPE L COPPER TUBE 150 3.97 0 10.00 0.177 185 Meter -3.00 45.85 22.01 190 1.00 psi -3.00 46.86 190 0.00 -3.00 0.00 46.86 2.00 0.00 0.00710 20.00 0.200 200 0.00 -7.00 0.00 48.79 1.816 22.01 B 8.20 1.732 HDPE SDR-9 150 2.73 0 28.20 1.932 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs RG 23 Prescott, AZ 86301 Page 4 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) Fitting Legend: F = 45 Degree Elbow, E = 90 Degree Elbow, L = Long Turn Elbow, T = Tee or Cross, B = Butterfly Valve, G = Gate Valve, C = Check Valve Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs RG 23 Prescott, AZ 86301 Page 5 Fire Sprinkler Output Summary Hydraulically Most Demanding Sprinkler Node HMD Sprinkler Node Number:5 HMD Actual Residual Pressure: 12.05 psi HMD Actual Flow:17.01 gpm Sprinkler Summary Sprinkler System Type:Wet Specified Area Of Application: 324.00 ft² Minimum Desired Density:0.050 gpm/ft² Application Average Density:0.052 gpm/ft² Application Average Area Per Sprinkler: 324.00 ft² Sprinkler Flow:17.01 gpm Average Sprinkler Flow:17.01 gpm Flow Velocity And Imbalance Summary Maximum Flow Velocity ( In Pipe 5 - 6 ) 9.10 ft/sec Maximum Velocity Pressure ( In Pipe 5 - 6 ) 0.56 psi Allowable Maximum Nodal Pressure Imbalance: 0.0100 psi Actual Maximum Nodal Pressure Imbalance: 0.0000 psi Actual Average Nodal Pressure Imbalance: 0.0000 psi Actual Maximum Nodal Flow Imbalance: -0.0011 gpm Actual Average Nodal Flow Imbalance: 0.0001 gpm Overall Network Summary Number Of Unique Pipe Sections: 24 Number Of Flowing Sprinklers:1 Pipe System Water Volume:18.51 gal Sprinkler Flow:17.01 gpm Non-Sprinkler Flow:5.00 gpm Minimum Required Residual Pressure At System Inflow Node:48.79 psi Demand Flow At System Inflow Node: 22.01 gpm Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs RG 23 Prescott, AZ 86301 Page 6 Fire Sprinkler Output Data Hydraulic Supply/Demand Graph Pressure psiFlowrate(x100) gpm 70 6363 0 10 20 30 40 50 60 70 80 90 100 1 2 3 4 5 6 7 8 9 10 Supply Curve Data Static Pressure: 70 psi Test Residual Pressure: 63 psi Test Flow Rate: 1000 gpm Demand Curve Data Calculated Residual Pressure: 48.79 psi Calculated Flow Rate: 22.01 gpm Excess Available Residual Pressure At Calculated Flow: 21.21 psi Pressure Required For First Sprinkler Downstream From Inflow Node To Flow: 0.00 psi OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org December 7, 2020 JD Mechanical Fire Inc. 82579 Fleming Way #D Indio, CA 92201 Re: Residential Fire Sprinkler Plan Review – WALKER RESIDENCE FSS2020-0154 / 81735 DE SOTO AVE, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 81735 DE SOTO AVE PERMIT#: FSS2020-0154 DATE ISSUED: 12/7/2020 DESCRIPTION: WALKER RESIDENCE CONTRACTOR: JD MECHANICAL FIRE INC HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.