Loading...
FSS2020-0155ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT SHASTA FIRE PROTECTION INC 72120 NORTHSHORE ST #C THOUSAND PALMS CA 92276 (760)404-1350 jpaulus@shastafire.co m BILL TO SHASTA FIRE PROTECTION INC 72120 NORTHSHORE ST #C THOUSAND PALMS CA 92276 (760)404-1350 jpaulus@shastafire.co m CONTRACTOR SHASTA FIRE PROTECTION INC 72120 NORTHSHORE ST #C THOUSAND PALMS CA 92276 (760)404-1350 jpaulus@shastafire.co m OWNER SHADOW ROCK CHURCH 46760 COMMERCE CT LA QUINTA CA 92253 (760)404-1350 bruce@attorneycpa.ne t CONDITIONS Description: SHADOW ROCK CHURCH - TI (BCOM2020-0009) Type: FIRE SPRINKLER (WEB)Subtype: TENANT IMPROVEMENT Status: FINALED Applied: 11/20/2020 ECON Parcel No: 600390018 Site Address: 46760 COMMERCE CT LA QUINTA,CA 92253 Approved: 12/7/2020 KHET Subdivision: PM 29351 Block: Lot: 8 Issued: 12/8/2020 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 2/8/2021 KHET Valuation: $2,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Friday, February 24, 2023 10:18:48 AM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0155 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 12/21/2020 12/21/2020 APPROVED REMOTE VIDEO INSPECTION OVERHEAD HYRO KHET 12/21/2020 12/21/2020 APPROVED REMOTE VIDEO INSPECTION FIRE FINAL**KHET 2/8/2021 2/8/2021 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS 101-0000-42420 0 $161.00 $161.00 12/8/20 WEB6932 28699C CREDIT SHASTA FIRE PROTECTION INC ECON FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS PC 101-0000-42420 0 $242.00 $242.00 12/8/20 WEB6932 28699C CREDIT SHASTA FIRE PROTECTION INC ECON Total Paid for FIRE FEES: $403.00 $403.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 12/8/20 WEB6932 28699C CREDIT SHASTA FIRE PROTECTION INC ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 12/8/20 WEB6932 28699C CREDIT SHASTA FIRE PROTECTION INC ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$418.00 $418.00 Printed: Friday, February 24, 2023 10:18:48 AM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0155 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/20/2020 EtrakitContractor 1ST SUBMITTAL PERMIT APPLICATION 20-019 FIRE DEPT PERMIT APP.pdf 1 DOC 11/20/2020 EtrakitContractor 1ST SUBMITTAL MATERIAL SUBMITTAL 20-019 MATERIAL SUBMITTAL.pdf 1 DOC 11/21/2020 EtrakitContractor 1ST SUBMITTAL SHADOW ROCK CHURCH T.I. REVISED FIRE SPRINKLER PLAN DATED 11-21-20 20-019 REVISED T.I. PLAN 11-21-20.pdf 1 DOC 11/21/2020 EtrakitContractor 1ST SUBMITTAL PENDANT HEADS VIKING MICROFAST SSP K 5.6 VK302.pdf 1 DOC 12/7/2020 KOHL HETRICK FSS2020-0155 - APPROVED PLANS.pdf FSS2020-0155 - APPROVED PLANS.pdf 1 DOC 12/7/2020 KOHL HETRICK FSS2020-0155 - COA AND JOB CARD.pdf FSS2020-0155 - COA AND JOB CARD.pdf 1 BOND INFORMATION 1ST FIRE (2 WK)KOHL HETRICK 11/20/2020 12/8/2020 12/7/2020 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 11/20/2020 11/23/2020 11/24/2020 COMPLETE Printed: Friday, February 24, 2023 10:18:48 AM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0155 FSS2020-0155 As the leading supplier of steel sprinkler pipe, we understand that there are no second chances in fire suppression. You need products of enduring quality and exceptional strength—plus reliable service. You need Bull Moose. SCHEDULE 10 & 40 ADVANTAGES: • UL listed (US & Canada) and FM approved • ASTM A135 and A795 Type E, Grade A Certified • Complies with NFPA-13, 13R and 14 • Industry-leading hydraulic characteristics • CRR of 1.0 and greater • All pipe NDT weld tested OTHER BENEFITS/SERVICES: • We have the most stocking locations in the industry, for best delivery and availability • Plain end or roll groove • Eddy Guard II™ bacterial-resistant internal coating • Custom length options • Hot dipped galvanization • Reddi-Pipe® red or black pipe eliminates field painting • Compatible for use in wet, dry, preaction and deluge sprinkler systems • The only maker with EPDs (to help earn LEED points). Always ready to protect your most valuable assets. SCHEDULE 10 & 40 Exclusive maker of Reddi-Pipe® RED OR BLACK PAINTED PIPE. 800.325.4467 sales@BullMooseIndustries.com BullMooseTube.com Nominal Pipe Size (Inches)1"1-1/4" 1-1/2"2"2-1/2"3"4"6"8" O.D. (in)1.315 1.660 1.900 2.375 2.875 3.500 4.500 6.625 8.625 I.D. (in)1.097 1.442 1.682 2.157 2.635 3.260 4.260 6.357 8.249 Empty Weight (lb/ft)1.410 1.810 2.090 2.640 3.530 4.340 5.620 9.290 16.940 Water Filled Weight (lb/ft)1.820 2.518 3.053 4.223 5.893 7.957 11.796 23.038 40.086 C.R.R.15.27 9.91 7.76 6.27 4.92 3.54 2.50 1.158 1.805 Pieces per Lift 91 61 61 37 30 19 19 10 7 Lift Weight (lbs) 21' lengths 2,695 2,319 2,677 2,051 2,224 1,732 2,242 1,951 2,490 Lift Weight (lbs) 24' lengths 3,079 2,650 3,060 2,344 2,542 1,979 2,563 2,230 2,848 Lift Weight (lbs) 25' lengths 3,208 2,760 3,187 2,442 2,648 2,062 2,670SCHEDULE 10NPS (In.)1"1-1/4" 1-1/2"2"2-1/2"3"4" 1.315 1.660 1.900 2.375 2.875 3.500 4.500 1.049 1.380 1.610 2.067 2.469 3.068 4.026 1.680 2.270 2.720 3.660 5.800 7.580 10.800 2.055 2.918 3.602 5.114 7.875 10.783 16.316 1.00 1.00 1.00 1.00 1.00 1.00 1.00 70 51 44 30 30 19 19 2,470 2,431 2,513 2,306 3,654 3,024 4,309 2,822 2,778 2,872 2,635 4,176 3,456 4,925 2,940 2,894 2,992 2,745 4,350 3,601 5,130SCHEDULE 40Bull Moose Fire Sprinkler Pipe Product Information As the leading supplier of steel sprinkler pipe, we understand that there are no second chances in fire suppression. You need products of enduring quality and exceptional strength—plus reliable service. You need Bull Moose. Always ready to protect your most valuable assets. EDDYTHREAD 40 800.325.4467 sales@BullMooseIndustries.com BullMooseTube.com Bull Moose Fire Sprinkler Pipe Product Information Nominal Pipe Size (Inches)1"1-1/4" 1-1/2"2"2-1/2"3"4"6"8" O.D. (in)1.295 1.650 1.900 2.375 I.D. (in)1.083 1.418 1.654 2.123 Empty Weight (lb/ft)1.461 2.070 2.547 3.308 Water Filled Weight (lb/ft)1.860 2.754 3.468 4.842 C.R.R.1.00 1.00 1.00 1.00 Pieces per Lift 70 51 44 30 Lift Weight (lbs) 21' lengths 2,148 2,217 2,353 2,084 Lift Weight (lbs) 24' lengths 2,454 2,534 2,690 2,382 Lift Weight (lbs) 25' lengths 2,557 2,639 2,802 2,481EDDYTHREAD 40 EDDYTHREAD 40 ADVANTAGES: • UL listed (US & Canada) and FM approved • ASTM A135 and A795 Type E, Grade A Certified • Complies with NFPA-13, 13R and 14 • Industry-leading hydraulic characteristics • CRR of 1.0 and greater • All pipe NDT weld tested OTHER BENEFITS/SERVICES: • We have the most stocking locations in the industry, for best delivery and availability • Plain end or roll groove • Eddy Guard II™ bacterial-resistant internal coating • Custom length options • Hot dipped galvanization • Reddi-Pipe® red or black pipe eliminates field painting • Compatible for use in wet, dry, preaction and deluge sprinkler systems • The only maker with EPDs (to help earn LEED points).Exclusive maker of Reddi-Pipe® RED OR BLACK PAINTED PIPE. PROJECT INFORMATION:APPROVAL STAMP: Project: Date: Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: REV. 03.03.06-006 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® MATERIAL SPECIFICATIONS Cast iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 300 psi service. Gray iron per ASTM A126 Class B. Dimensions conform to ANSI B16.4 Class 125. Threads are NPT per ANSI/ASME B1.20.1. BULL HEAD TEE Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. EachABC In. (mm) In. (mm) PSI (kPa) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 1 x 1 x 11⁄4 800004285 CT334 300 1.67 1.67 1.58 1.52 25 x 25 x 32 2065 42.418 42.418 40.132 0.69 1 x 1 x 11⁄2 800004293 CT335 300 1.8 1.8 1.65 1.73 25 x 25 x 40 2065 45.72 45.72 41.91 0.78 11⁄4 x 1 x 11⁄2 800004343 CT435 300 1.88 1.8 1.82 2.05 32 x 25 x 40 2065 47.752 45.72 46.228 0.93 11⁄4 x 11⁄4 x 11⁄2 800004384 CT445 300 1.88 1.88 1.82 2.21 32 x 32 x 40 2065 47.752 47.752 46.228 1.00 11⁄4 x 1 1⁄4 x 2 800004392 CT446 300 2.1 2.1 1.9 2.55 25 x 25 x 40 2065 53.34 53.34 48.26 1.16 11⁄2 x 11⁄4 x 2 800004509 CT546 300 2.16 2.1 2.02 2.80 40 x 32 x 40 2065 54.864 53.34 51.308 1.27 11⁄2 x 11⁄2 x 2 800004558 CT556 300 2.16 2.16 2.02 3.28 40 x 40 x 50 2065 54.864 54.864 51.308 1.41 2 x 2 x 21⁄2 800004699 CT667 300 2.6 2.6 2.39 5.10 50 x 50 x 60 2065 66.04 66.04 60.706 2.31 C AB BULL HEAD TEE Cast Iron - Class 125 Fittings PROJECT INFORMATION:APPROVAL STAMP: Project: Date: Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: REV. 03.03.06-005 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® MATERIAL SPECIFICATIONS Cast iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 300 psi service. Gray iron per ASTM A126 Class B. Dimensions conform to ANSI B16.4 Class 125. Threads are NPT per ANSI/ASME B1.20.1. REDUCING TEE Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. EachABC In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm)Lbs. (kg) 1 x 1⁄2 x 1 800004244 CT313 300 1.50 1.36 1.50 1.08 25 x 15 x 25 2065 38.10 34.54 38.10 0.49 1 x 3⁄4 x 1 800004251 CT323 300 1.50 1.45 1.50 1.18 25 x 20 x 25 2065 38.10 36.83 38.10 0.54 1 x 1 x 1⁄2 800004269 CT331 300 1.26 1.26 1.36 0.95 25 x 25 x 15 2065 32.00 32.00 34.54 0.43 1 x 1 x 3⁄4 800004277 CT332 300 1.37 1.37 1.45 1.10 25 x 25 x 20 2065 34.79 34.79 36.83 0.50 11⁄4 x 1 x 1⁄2 800004301 CT431 300 1.34 1.26 1.53 1.17 32 x 25 x 15 2065 34.03 32.00 38.86 0.53 11⁄4 x 1 x 3⁄4 800004319 CT432 300 1.45 1.37 1.62 1.38 32 x 25 x 20 2065 36.83 34.79 41.14 0.63 11⁄4 x 1 x 1 800004327 CT433 300 1.58 1.50 1.57 1.47 32 x 25 x 25 2065 40.13 38.10 39.87 0.67 11⁄4 x 1 x 11⁄4 800004335 CT434 300 1.75 1.67 1.75 1.80 32 x 25 x 32 2065 44.45 42.41 44.45 0.82 11⁄4 x 11⁄4 x 1⁄2 800004350 CT441 300 1.34 1.34 1.53 1.37 32 x 32 x 15 2065 34.03 34.03 38.86 0.62 11⁄4 x 11⁄4 x 3⁄4 800004368 CT442 300 1.45 1.45 1.62 1.54 32 x 32 x 20 2065 36.83 36.83 41.14 0.70 11⁄4 x 11⁄4 x 1 800004376 CT443 300 1.58 1.58 1.67 1.65 32 x 32 x 25 2065 40.13 40.13 42.41 0.75 11⁄2 x 1 x 1⁄2 800004400 CT531 300 1.41 1.34 1.66 1.41 40 x 25 x 15 2065 35.81 34.03 42.16 0.64 11⁄2 x 1 x 3⁄4 800004418 CT532 300 1.52 1.37 1.75 1.65 40 x 25 x 20 2065 38.60 34.79 44.45 0.75 11⁄2 x 1 x 1 800004426 CT533 300 1.65 1.50 1.80 1.65 40 x 25 x 25 2065 41.91 38.10 45.72 0.75 11⁄2 x 1 x 11⁄4 800004434 CT534 300 1.82 1.67 1.88 2.00 40 x 25 x 32 2065 46.22 42.41 47.75 0.91 11⁄2 x 1 x 11⁄2 800004442 CT535 300 1.94 1.8 1.94 2.30 40 x 25 x 40 2065 49.27 45.72 49.27 1.04 11⁄2 x 11⁄4 x 1⁄2 800004459 CT541 300 1.41 1.34 1.66 1.58 40 x 32 x 15 2065 35.81 34.03 42.16 0.72 11⁄2 x 11⁄4 x 3⁄4 800004467 CT542 300 1.52 1.45 1.75 1.72 40 x 32 x 20 2065 38.60 36.83 44.45 0.78 11⁄2 x 11⁄4 x 1 800004475 CT543 300 1.65 1.58 1.80 1.85 40 x 32 x 25 2065 41.91 40.13 45.72 0.84 REDUCING TEE Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. EachABC In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm)Lbs. (kg) 11⁄2 x 11⁄4 x 11⁄4 800004483 CT544 300 1.82 1.75 1.88 2.22 40 x 32 x 32 2065 46.22 44.45 47.75 1.00 11⁄2 x 11⁄4 x 11⁄2 800004491 CT545 300 1.94 1.88 1.94 2.45 40 x 32 x 15 2065 49.27 47.75 49.27 1.11 11⁄2 x 11⁄2 x 1⁄2 800004517 CT551 300 1.41 1.41 1.66 1.76 40 x 40 x 40 2065 35.81 35.81 42.16 0.80 11⁄2 x 11⁄2 x 3⁄4 800004525 CT552 300 1.52 1.52 1.75 1.87 40 x 40 x 20 2065 38.60 38.60 44.45 0.85 11⁄2 x 11⁄2 x 1 800004533 CT553 300 1.65 1.65 1.80 1.94 40 x 40 x 25 2065 41.91 41.91 45.72 0.88 11⁄2 x 11⁄2 x 11⁄4 800004541 CT554 300 1.82 1.82 1.88 2.29 40 x 40 x 32 2065 46.22 46.22 47.75 1.04 2 x 1 x 2 800004566 CT636 300 2.25 2.02 2.25 3.40 50 x 25 x 50 2065 57.15 51.30 57.15 1.54 2 x 11⁄4 x 2 800004574 CT646 300 2.25 2.10 2.25 2.80 50 x 32 x 50 2065 57.15 53.34 57.15 1.27 2 x 11⁄2 x 1⁄2 800004582 CT651 300 1.49 1.41 1.88 2.09 50 x 40 x 15 2065 37.84 35.81 47.75 0.95 2 x 11⁄2 x 3⁄4 800004590 CT652 300 1.60 1.52 1.97 2.40 50 x 40 x 20 2065 40.64 38.60 50.03 1.09 2 x 11⁄2 x 1 800004608 CT653 300 1.73 1.65 2.02 2.54 50 x 40 x 25 2065 43.94 41.91 51.30 1.15 2 x 11⁄2 x 11⁄4 800004616 CT654 300 1.90 1.82 2.10 2.85 50 x 40 x 32 2065 48.26 46.22 53.34 1.30 2 x 11⁄2 x 11⁄2 800004624 CT655 300 1.49 1.41 1.88 2.24 50 x 40 x 40 2065 37.84 35.81 47.75 1.02 2 x 11⁄2 x2 800004632 CT656 300 2.25 2.16 2.25 3.75 50 x 40 x 50 2065 57.15 54.86 57.15 1.70 2 x 2 x 1⁄2 800004640 CT661 300 1.49 1.49 1.88 2.60 50 x 50 x 15 2065 37.84 37.84 47.75 1.18 2 x 2 x 3⁄4 800004657 CT662 300 1.60 1.60 1.97 2.71 50 x 50 x 20 2065 40.64 40.64 50.03 1.23 2 x 2 x1 800004665 CT663 300 1.73 1.73 2.02 2.97 50 x 50 x 15 2065 43.94 43.94 51.30 1.35 2 x 2 x11⁄4 800004673 CT664 300 1.90 1.90 2.10 3.32 50 x 50 x 32 2065 48.26 48.26 53.34 1.51 2 x 2 x11⁄2 800004681 CT665 300 2.02 2.02 2.16 3.72 50 x 50 x 40 2065 51.30 51.30 54.86 1.69 C AB REDUCING TEE Cast Iron - Class 125 Fittings PROJECT INFORMATION:APPROVAL STAMP: Project: Date: Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: REV. 03.03.06-004 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® MATERIAL SPECIFICATIONS Cast iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 300 psi service. Gray iron per ASTM A126 Class B. Dimensions conform to ANSI B16.4 Class 125. Threads are NPT per ANSI/ASME B1.20.1. STRAIGHT TEE Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. EachAB In. (mm) PSI (kPa) In. (mm) In. (mm) Lbs. (kg) 1 800003204 CT333 300 1.50 1.50 1.21 25 2065 38.10 38.10 0.55 11⁄4 800003212 CT444 300 1.75 1.75 1.87 32 2065 44.45 44.45 0.85 11⁄2 800003220 CT555 300 1.94 1.94 2.51 40 2065 49.27 49.27 1.14 2 800003238 CT666 300 2.25 2.25 3.96 50 2065 57.15 57.15 1.80 21⁄2 800003246 CT777 300 2.70 2.70 6.45 65 2065 68.58 68.58 2.93 B AA STRAIGHT TEE Cast Iron - Class 125 Fittings PROJECT INFORMATION APPROVAL STAMP Project:❑ Approved Address:❑ Approved as noted Contractor:❑ Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: 5/09 The Gruvlok® Figure 7000 Lightweight Coupling is designed for applications where system flexibility is desired. The Figure 7000 Lightweight Coupling is approximately 30% lighter in weight than the Figure 7001 Coupling. Working pressure ratings shown are for reference only and are based on Schedule 40 pipe. For the latest UL/ULC listed and FM approved pressure ratings versus pipe schedule, see www.anvilstar.com or contact your local AnvilStar Representative. The Figure 7000 Lightweight Coupling with a Pre-Lubricated Grade “E” EPDM, Type “A” gasket (coupling is easily identified by purple nuts) is intended for use in fire protection systems installed in accordance with NFPA Standard 13 “Sprinkler Systems”. MATERIAL SPECIFICATIONS HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval-neck track head bolts conforming to ASTM A-183 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A-563 Grade A or Grade B, or J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. COATINGS: Rust inhibiting paint Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other available options: Example: RAL3000 or RAL9000 Series For other coating requirements contact an AnvilStar Representative. LUBRICATION: Standard Gruvlok Gruvlok Xtreme™ required for dry pipe systems and freezer applications. GASKETS: Materials Properties as designated in accordance with ASTM D-2000. Pre-Lubricated Grade “E” EPDM, Type A Gasket (Violet color code) -40°F to 150°F (Service Temperature Range)(-40°C to 66°C) Recommended for wet and dry (oil free air) pipe fire protection sprinkler systems. For dry pipe systems and freezer applications, Gruvlok Xtreme™ Lubricant is required. Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. GASKET TYPE: Standard C Style Flush Gap (11/4”-8”) – Available galvanized. * When ordering, refer to product as FP7400. For Listing/Approval Details and Limitations, visit our website at www.anvilstar.com or contact an Anvil®/AnvilStar™ Sales Representative. FIG. 7000* Lightweight Flexible Coupling 5/09 For dry pipe systems and freezer applications lubrication of the gasket is required, Gruvlok® Xtreme™ Lubricant is required. Not for use in copper system. § – For additional Bolt Torque information see Technical Data Section. Other sizes available, see Gruvlok Catalog or contact an AnvilStar Representative. Y Z X FIGURE 7000 LIGHTWEIGHT COUPLING Nominal Size Pipe O.D. Max. Working Pressure Max. End Load Range of Pipe End Separation Deflection From CL Coupling Dimensions Coupling Bolts Specified Torque §Approx. Wt. Ea.Per Coupling Pipe X Y Z Qty. Size Min. Max. In./DN(mm) In./mm PSI/bar Lbs./kN In./mm Degrees In./Ft. In./mm In./mm In./mm In./mm Ft.-Lbs./N-m Lbs./Kg 11⁄4 1.660 600 1,299 0- 1⁄8 4° 19' 0.90 2 3⁄4 43⁄8 13⁄4 2 3⁄8 x 21⁄4 30 45 1.4 32 42.2 41.4 5.78 0-3.2 75.3 70 111 44 M10 x 57 40 60 0.6 11⁄2 1.900 600 1,701 0- 1⁄8 3° 46' 0.79 3 4 5⁄8 13⁄4 2 3⁄8 x 21⁄4 30 45 1.5 40 48.3 41.4 7.57 0-3.2 65.7 76 117 44 M10 x 57 40 60 0.7 2 2.375 600 2,658 0- 1⁄8 3° 1' 0.63 3 1⁄2 51⁄2 13⁄4 2 3⁄8 x 21⁄4 30 45 1.7 50 60.3 41.4 11.82 0-3.2 52.6 89 140 44 M10 x 57 40 60 0.8 21⁄2 2.875 600 3,895 0- 1⁄8 2° 29' 0.52 4 5 3⁄4 13⁄4 2 3⁄8 x 21⁄4 30 45 1.9 65 73.0 41.4 17.33 0-3.2 43.3 102 146 44 M10 x 57 40 60 0.9 3 O.D. 2.996 600 4,230 0- 1⁄8 2° 23' 0.50 4 6 1⁄8 13⁄4 2 3⁄8 x 21⁄4 80 100 2.3 76.1 76.1 41.4 18.82 0-3.2 41.6 102 156 44 M10 x 57 110 150 1.0 3 3.500 600 5,773 0- 1⁄8 2° 3' 0.43 4 5⁄8 63⁄4 13⁄4 2 1⁄2 x 23⁄4 80 100 2.9 80 88.9 41.4 25.68 0-3.2 35.8 117 171 44 M12 x 70 110 150 1.3 41⁄4 O.D. 4.250 600 8,512 0- 1⁄4 3° 22' 0.70 5 1⁄2 73⁄4 22 1⁄2 x 3 80 100 4.0 108.0 108.0 41.4 37.86 0-6.4 58.7 140 197 51 M12 x 76 110 150 1.8 4 4.500 600 9,543 0- 1⁄4 3° 11' 0.67 5 7⁄8 81⁄8 22 1⁄2 x 3 80 100 4.6 100 114.3 41.4 42.45 0-6.4 55.5 149 206 51 M12 x 76 110 150 2.1 51⁄4 O.D. 5.236 500 10,766 0- 1⁄4 2° 44' 0.57 6 1⁄2 91⁄8 225⁄8 x 31⁄2 100 130 5.7 133.0 133.0 34.5 47.89 0-6.4 47.7 165 232 51 M16 x 85 135 175 2.6 51⁄2 O.D. 5.500 500 11,879 0- 1⁄4 2° 36' 0.54 6 3⁄4 93⁄8 225⁄8 x 31⁄2 100 130 6 139.7 139.7 34.5 52.84 0-6.4 45.4 171 238 51 M16 x 85 135 175 2.7 5 5.563 500 12,153 0- 1⁄4 2° 35' 0.54 7 9 5⁄8 225⁄8 x 31⁄2 100 130 6.1 125 141.3 34.5 54.06 0-6.4 45.1 178 244 51 M16 x 85 135 175 2.8 61⁄4 O.D. 6.259 500 15,384 0- 1⁄4 2° 17' 0.48 7 1⁄2 103⁄8 225⁄8 x 31⁄2 100 130 6.7 159.0 159.0 34.5 68.43 0-6.4 39.8 191 264 51 M16 x 85 135 175 3.0 61⁄2 O.D. 6.500 500 16,592 0- 1⁄4 2° 12' 0.46 7 3⁄4 103⁄4 225⁄8 x 31⁄2 100 130 7.0 165.1 165.1 34.5 73.80 0-6.4 34.8 197 273 51 M16 x 85 135 175 3.2 6 6.625 500 17,236 0- 1⁄4 2° 10' 0.45 8 11 2 2 5⁄8 x 31⁄2 100 130 8.1 150 168.3 34.5 76.67 0-6.4 37.8 203 279 51 M16 x 85 135 175 3.7 8 8.625 500 29,213 0- 1⁄4 1° 40' 0.35 10 13 1⁄4 23⁄8 2 3⁄4 x 41⁄2 130 180 14.2 200 219.1 34.5 129.95 0-6.4 29.1 264 337 60 M20 x 110 175 245 6.4 FIG. 7000* Lightweight Flexible Coupling PROJECT INFORMATION APPROVAL STAMP Project:❑ Approved Address:❑ Approved as noted Contractor:❑ Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: 5/09 The Gruvlok® Figure 7010 Reducing Coupling makes it possible to directly connect two different pipe sizes, elimi- nating the need for two couplings and a reducing fitting. The specially designed reducing coupling gasket with a center rib assures proper positioning of the gasket and prevents the smaller pipe from telescoping into the larger during assembly. Working pressure ratings shown are for reference only and are based on Schedule 40 pipe. For the latest UL/ULC listed and FM approved pressure ratings versus pipe schedule, see www.anvilstar.com or contact your local AnvilStar Representative. Figure 7010 Coupling complete with Grade “E” EPDM Gasket. MATERIAL SPECIFICATIONS HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Malleable Iron conforming to ASTM A-47, Grade 32510 ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval-neck track head bolts conforming to ASTM A-183 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A-563 Grade A or Grade B, or J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. COATINGS: Rust inhibiting paint Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other available options: Example: RAL3000 or RAL9000 Series For other coating requirements contact an AnvilStar Representative. LUBRICATION: Standard Gruvlok Gruvlok Xtreme™ required for dry pipe systems and freezer applications. GASKETS: Materials Properties as designated in accordance with ASTM D-2000. Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. – Available galvanized. For Listing/Approval Details and Limitations, visit our website at www.anvilstar.com or contact an Anvil®/AnvilStar™ Sales Representative. FIG. 7010 Reducing Coupling 5/09 FIGURE 7010 REDUCING COUPLING Nominal Size Larger O.D. Smaller O.D. Max. Working Pressure Max. End Load Range of Pipe End Separation Deflection From CL Coupling Dimensions Coupling Bolts Specified Torque §Approx. Wt. Ea.Per Coupling Pipe X Y Z Qty.Size Min. Max. In./DN(mm) In./mm In./mm PSI/bar Lbs./kN In./mm Degrees mm/m In./mm In./mm In./mm In./mm Ft.-Lbs./N-m Lbs./Kg 2 x 11⁄2 2.375 1.900 500 2,215 0- 1⁄8 1° 53' 0.39 3 5⁄8 57⁄8 17⁄8 2 1⁄2 x 23⁄4 80 100 2.0 50 x 40 60.3 48.3 34.5 9.85 0-3.2 32.9 92 149 48 M12 x 70 110 150 0.9 21⁄2 x 2 2.875 2.375 500 3,246 0- 1⁄8 1° 33' 0.32 4 1⁄4 63⁄8 17⁄8 2 1⁄2 x 23⁄4 80 100 3.5 65 x 50 73.0 60.3 34.5 14.44 0-3.2 27.0 108 162 48 M12 x 70 110 150 1.6 3 x 2 3.500 2.375 500 4,811 0- 1⁄8 1° 17' 0.27 4 7⁄8 71⁄8 17⁄8 2 1⁄2 x 23⁄4 80 100 4.4 80 x 50 88.9 60.3 34.5 21.40 0-3.2 22.4 124 181 48 M12 x 70 110 150 2.0 3 x 21⁄2 3.500 2.875 500 4,811 0- 1⁄8 1° 17' 0.27 4 7⁄8 71⁄8 17⁄8 2 1⁄2 x 23⁄4 80 100 4.1 80 x 65 88.9 73.0 34.5 21.40 0-3.2 22.4 124 181 48 M12 x 70 110 150 1.9 4 x 2 4.500 2.375 500 7,952 0- 3⁄16 2° 38' 0.55 6 1⁄4 87⁄8 22 5⁄8 x 31⁄2 100 130 8.9 100 x 50 114.3 60.3 34.5 35.37 0-4.8 45.9 159 225 51 M16 x 85 135 175 4.0 4 x 21⁄2 4.500 2.875 500 7,952 0- 3⁄16 2° 38' 0.55 6 1⁄4 87⁄8 22 5⁄8 x 31⁄2 100 130 7.9 100 x 65 114.3 73.0 34.5 35.37 0–4.8 45.9 159 225 51 M16 x 85 135 175 3.6 4 x 3 4.500 3.500 500 7,952 0- 3⁄16 2° 38' 0.55 6 1⁄4 87⁄8 22 5⁄8 x 31⁄2 100 130 6.7 100 x 80 114.3 88.9 34.5 35.37 0-4.8 45.9 159 225 51 M16 x 85 135 175 3.0 5 x 4 5.563 4.500 500 12,153 0- 1⁄4 2° 5' 0.44 7 1⁄4 105⁄8 21⁄8 2 3⁄4 x 41⁄2 130 180 11.4 125 x 100 141.3 114.3 34.5 54.06 0-6.4 36.4 184 270 54 M20 x 110 175 245 5.2 6 x 4 6.625 4.500 500 17,236 0- 1⁄4 1° 44' 0.36 8 1⁄4 115⁄8 21⁄8 2 3⁄4 x 41⁄2 130 180 13.4 150 x 100 168.3 114.3 34.5 76.67 0-6.4 30.2 210 295 54 M20 x 110 175 245 6.1 6 x 5 6.625 5.562 500 17,236 0- 1⁄4 1° 44' 0.36 8 1⁄2 115⁄8 21⁄8 2 3⁄4 x 41⁄2 130 180 13.5 150 x 125 168.3 141.3 34.5 76.67 0-6.4 30.2 216 295 54 M20 x 110 175 245 6.1 8 x 6 8.625 6.625 500 29,213 0- 1⁄4 1° 15' 0.26 10 1⁄2 14 2 1⁄4 2 3⁄4 x 41⁄2 130 180 17.7 200 x 150 219.1 168.3 34.5 129.95 0-6.4 21.8 267 356 57 M20 x 110 175 245 8.0 For dry pipe systems and freezer applications lubrication of the gasket is required, Gruvlok® Xtreme™ Lubricant is required. Not for use in copper system. See technical data section for coupling data chart notes. § – For additional Bolt Torque information see Technical Data Section. Other sizes available, see Gruvlok Catalog or contact an AnvilStar Representative. FIG. 7010 Reducing Coupling OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org December 7, 2020 Shasta Fire Protection Inc 72120 Northshore St. #C Thousand Palms, CA 92276 Re: TI Fire Sprinkler Plan Review – SHADOW ROCK CHURCH FSS2020-0155 / 46760 COMMERCE CT, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. The following inspections/tests are required to be witnessed by the Office of the Fire Marshal staff: 1) Overhead Rough: All installed/relocated piping must be visible. 2) Final inspection: All trim is in place, 5-Year certification is current. New/added heads shall be included in the spare head box compliment. *Water-flow signal test may be performed during the Final Inspection. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 46760 COMMERCE CT PERMIT#: FSS2020-0155 DATE ISSUED: 12/7/2020 DESCRIPTION: SHADOW ROCK CHURCH TI CONTRACTOR: SHASTA FIRE PROTECTION INC HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. DESIGN & DEVELOPMENT DEPARTMENT 78-495 Calle Tampico La Quinta, California 92253 (760) 777-7125 / FAX (760) 777-7011  NEW  TENANT IMPROVEMENT PERMIT NO. PROJECT INFORMATION (Please Print) Project Name: Sign: Site Address: Print: City & Zip: Project Description: • Pursuant to a Cooperative Agreement to Provide Fire Services, the Riverside County Fire Department serves as the City’s fire department, and the County designee serves as the City’s fire chief. Applicant recognizes this contracted arrangement and shall comply with County Fire Department directions. APPLICANT/CONTACT INFORMATION CONTRACTOR INFORMATION:  Same as Applicant info Applicant Name: Contractor #: Contact Person: Contact Person: Mailing Address: Mailing Address: City & Zip: City & Zip: Phone Number: Fax : Phone Number: Fax : Email: Email:  ------------  HOURLY@161/HR  $670  HOURLY@161/HR  $791  $992  $418  $1234  HOURLY@161/HR $418  HOURLY@161/HR ------------  HOURLY@161/HR $418  $498  HOURLY@161/HR  $579  HOURLY@161/HR  $176  $901  $590  HOURLY@161/HR  $659  $418  $579  $1062  $418  $740  HOURLY@161/HR  HOURLY@161/HR  HOURLY@161/HR  HOURLY@161/HR