FSS2020-0157ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE JOSE DELGADO 12/2/2021 12/13/2021 CONTRACTOR REQUESTED FINAL INSPECTION. PERMIT EXPIRED AS OF 6/7/21 (6 MOS FROM DATE OF LAST APPROVED INSPECTION). ADDED EXTENSION FEE OF $83 AND EXTENDED PERMIT TO 12/3/21 SO CONTRACTOR CAN PAY FEE VIA ETRAKIT. WILL ALSO REQUIRE AN EXTENSION REQUEST LETTER FROM CONTRACTOR. OK TO EXTEND PER KOHL. ALSO NOTIFIED CONTRACTOR THAT THEIR BUSINESS LICENSE HAS BEEN EXPIRED AS OF 11/30/21 AND WOULD NEED TO RENEW IT. CONTRACTOR SUBMITTED EXTENSION LETTER AND FEE'S HAVE BEEN PAID. PERMIT EXTENDED 6 MONTHS FROM DATE EXTENSION LETTER WAS SUBMITTED. CONDITIONS Description: SIEGALL / BRES2020-0121 /TENANT IMPROVEMENT/ HOME ADDITION Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 11/23/2020 EPRS Parcel No: 767670010 Site Address: 81175 ELSWORTH PL LA QUINTA,CA 92253 Approved: 12/8/2020 KHET Subdivision: TR 33076-1 Block: Lot: 14 Issued: 12/9/2020 AMA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 12/16/2021 KHET Valuation: $4,300.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Friday, February 24, 2023 10:35:30 AM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0157 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT simon chavero 82417 priscilla ct indio CA 92201 (760)574-6512 simon@silveradofire.c om BILL TO simon chavero 82417 priscilla ct indio CA 92201 (760)574-6512 info@silveradofire.com CONTRACTOR SILVERADO FIRE PROTECTION 82417 PRISCILLA STREET INDIO CA 92201 (760)574-6512 SIMON@SILVERADOFI RE.COM OWNER CLAY SIEGALL 82417 priscilla ct indio CA 92201 (760)574-6512 info@silveradofire.com INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $161.00 $161.00 12/9/20 R63237 INVOICE 65 CREDIT SIMON CHAVERO AMA FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $242.00 $242.00 12/9/20 R63237 INVOICE 65 CREDIT SIMON CHAVERO AMA FIRE STAFF - PER HOUR 101-0000-42420 1 $83.00 $83.00 12/6/21 WEB10075 634063289 65 CREDIT simon chavero EPRS Total Paid for FIRE FEES: $486.00 $486.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 12/9/20 R63237 INVOICE 65 CREDIT SIMON CHAVERO AMA Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 12/9/20 R63237 INVOICE 65 CREDIT SIMON CHAVERO AMA Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$501.00 $501.00 Printed: Friday, February 24, 2023 10:35:30 AM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0157 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/23/2020 EtrakitPublicReg 1ST SUBMITTAL CVWD CONNECTION CVWD Connection Letter.pdf 1 DOC 11/23/2020 EtrakitPublicReg 1ST SUBMITTAL FLOW ANALYSIS CVWD - Fire Flow Letter.pdf 1 DOC 11/23/2020 EtrakitPublicReg 1ST SUBMITTAL PENDANT Globe Recessed Pendent GL4110 (5).pdf 1 DOC 11/23/2020 EtrakitPublicReg 1ST SUBMITTAL GL4906 Globe GL4906 4.9K (2).pdf 1 DOC 11/23/2020 EtrakitPublicReg 1ST SUBMITTAL SPRINKLER PLAN Siegall Residence.pdf2nd Floor.pdf 1 BOND INFORMATION SCHEDULED DATE COMPLETED DATE OVERHEAD HYRO KHET 12/14/2020 12/14/2020 APPROVED REMOTE VIDEO INSPECTION OVERHEAD ROUGH PIPING KHET 12/14/2020 12/14/2020 APPROVED REMOTE VIDEO INSPECTION CONTRACTOR TO TAKE PHOTOS OF CONNECTION OF NEW PIPING TO EXISTING SYSTEM IN 1ST FLOOR HALLWAY OFF OF GARAGE. FIRE FINAL**KHET 12/16/2021 12/16/2021 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 11/23/2020 12/9/2020 12/8/2020 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 11/23/2020 11/24/2020 11/24/2020 COMPLETE PARENT PROJECTS Printed: Friday, February 24, 2023 10:35:30 AM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0157 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/23/2020 EtrakitPublicReg 1ST SUBMITTAL PLAN 1ST FLOOR SPRINKLER Siegall Residence.pdf1st Floor.pdf 1 DOC 11/23/2020 EtrakitPublicReg 1ST SUBMITTAL 2ND FLOOR 09-S2.PDF 1 DOC 11/23/2020 EtrakitPublicReg 1ST SUBMITTAL PLAN 1ST FLOOR 08-S1 (1).PDF 1 DOC 12/13/2021 JOSE DELGADO Extension letter request Elsworth pl.pdf Elsworth pl.pdf 0 DOC 12/8/2020 KOHL HETRICK FSS2020-0157 - APPROVED PLANS.pdf FSS2020-0157 - APPROVED PLANS.pdf 1 DOC 12/8/2020 KOHL HETRICK FSS2020-0157 - COA AND JOB CARD.pdf FSS2020-0157 - COA AND JOB CARD.pdf 1 DOC 12/14/2020 KOHL HETRICK FSS2020-0157 - 12-14-20 INSP AS-BULTS.pdf FSS2020-0157 - 12-14-20 INSP AS-BULTS.pdf 1 Printed: Friday, February 24, 2023 10:35:30 AM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0157 (N) BEDROOM (N) BATH HALL 1 3/8" 1 1/2" DRYERVENTS 100 GAL. 75 GAL. 600 AMP 26802680POCKET3080FR. FR.13420 FIXEDPR. 2680FR. DRS.2030CSMT. 1280FIXED 1280FIXED 2080FIXEDFR. DR. 2080FIXEDFR. DR.2680NEWGATE SEAT CLOSETMASTER BEDROOM PATIOHIS CLOSET HIS MASTER BATH STEAM ENTRY GREAT ROOM DINING ROOM WINE ENTRY COURT (E) HER CLOSET (E) HER MASTER BATH CASITA LIVING ROOM (E) BEDROOM 5 (E) BATH 5 BATH 4 BEDROOM 4 ENTRY LN. KIT. LOGGIA BEDROOM 2 BATH 2 POWDERSERVICE GARAGE GOLF ROOM GOLF CART BACK KITCHEN KITCHEN PATIO BBQ BAR BAR OUTDOOR SHOWER OUTDOOR SHOWER TREE WELL CL. (E) CL MECH PRIVATE SANCTUARY PRIVATE SPA PRIVATE VANITY DOG WASH SWIM UP BAR SPA A/V PRIVATE PATIO (E) PATIOPATIO POOL BATH PORTO COCHERE COURTYARD D D W W D W W/D LINEN PANTRY UPUPPROVIDE OUTSIDECOMBUSTION AIR -VENT TO ROOF PROVIDE OUTSIDECOMBUSTION AIR 775 SQ.FT. NFPA 13D REFERANCE NOTES 1. NFPA 13D, Section 8.3.2 Sprinklers shall not be required in bathrooms of 55 sq. ft. and less. 2. NFPA 13D, Section 8.3.3 Sprinklers shall not be required in clothes closets, linen closets, and pantries that meet all of the following conditions. (1) The area of the space does not exceed 24 sq. ft. (2) The walls and ceilings are surfaced with noncombustible or limited-combustible material as defined in NFPA 220. 3. NFPA 13D Section 8.3.4 Sprinklers shall not be required in garages, open attached porches, carports, and similar structures. Note that CFC 2016 Chapter 80 Referance Standards requires attached garages, attached porches, carports, and similar structures shall be sprinklered if there is occupied living space above. 4. NFPA 13D Section 8.2.5.6 Shadow Areas Shadow areas shall be permitted in the protection area of a sprinkler as long as the cumulative dry areas do not exceed 15 sq. ft. (1.4 sq. m.) per sprinkler. SPRINKLER PIPEINSULATION BOTTOM CORD OF ROOF TRUSS OR CEILING JOIST PIPE INSULATION DETAIL CPVC HANGERS NO SCALE TOLCO FIG. 24 DOUBLE-FASTENER SIDE-MOUNT HANGER (OR EQUAL) SELF-DRILLING HEX HEAD SCREW TOLCO FIG. 23 DOUBLE-FASTENER STRAP TYPE HANGER (OR EQUAL) TOLCO FIG. 28M OFFSET HANGER (OR EQUAL) TOLCO FIG. 22 SINGLE-FASTENER STRAP-TYPE HANGER (OR EQUAL) TOLCO FIG. 28 DOUBLE-FASTENER STAND-OFF HANGER (OR EQUAL) TOLCO FIG. 29 DOUBLE-FASTENER DOUBLE OFFSET HANGER (OR EQUAL) CPVC HANGER SPACING PIPE SIZE 11/4" 1" MAXIMUM SUPPORT SPACING 6'-6" 6'-0" 2"8'-0" 11/2"7'-0" Existing 1-1/4" Riser E E E E N N N N N NN NN N N N These 6 heads will be lowered 14" in the clouded area only as the ceiling will lowered to accomadate the new 2nd floor bedrooms 1" COMING DOWN FROM 2nd FLOOR Fire Department Notes A. The installation of new fire sprinkler systems or modifications to existing systems shall comply with the following: NFPA 13D 2016 CBC 2019 CFC 2019 Local Municipal Codes Requirements of the AHJ All Manufacture Installation Guidelines Note: When conflict arrises between existing codes and standards, the most stringent shall apply. B. The Fire Department Shall require the following inspections and tests. 1. Overhead installation and hydrostatic test, ( prior to cover ). a. Normal opperating pressure when no FDC is installed. b. 200psi when FDC is required. c. Two hour minimum. 2. Final sprinkler and underground, ( prior to building final ). a. All inspections shall be scheduled by the contractor of record. b. Inspections shall be scheduled 24 hours in advance. GENERAL NOTES 1.General: All materials and devices shall conform to 2016 NFPA 13D standards. Installation shall conform to all applcable State and Local Codes. 2.Scope of Work: Install a new T.I. Residential Fire Protection System. 3.Piping: All overhead pipe and fittings shall be CPVC unless otherwise noted. 4.Design: NFPA 13D 2016 Edition and CFC Chapter 80 Standards. 5.System Demand @ Source. Two Sprinklers Flowing (16X16 Spacing): 31 gpm @ ______psi ( 512 sf Max ) 6.Water Supply Data: Water is supplied from public water main in street. Static Pressure: Information Source: 7.Sprinkler Head Spacing and Installation Requirements:Sprinklers shall not be located Closer than 8'-0" apart where there is no intervening obstruction. Sprinklers near potential obstruction shall be located per manufactures instructions. 8.Piping Supports: Piping shall be supported and restrained in conformance with local plumbing codes and CPVC manufactures instructions . Eachpipe section that supplies a drop to a sprinkler shall be secured no more than 12" from the drop to prevent laterial and vertical movement. 9.Pipe lenghts are approximate for hydraulic calculation and plan review purposes only. 10.The owner shall furnish sufficant heat in all areas to prevent freezingof pipe. 11.Waterflow Switch and Alarm: By Others a. A dedicated electrical circuit with a circuit breaker lock shall be provided for waterflow horn/strobes. b. An approved audible sprinkler waterflow alarm shall be visible from the street. The device shall be listed for outdoor use. An approved sign shall be placed at or near the device stating, SPRINKLER FIRE ALARM - WHEN ALARM SOUNDS CALL 911 c. An approved audible sprinkler waterflow alarm module shall be conected to the smoke detectors to alert occupants shall be provided. simon@silverado Scale Project number Date Drawn by Checked by Silverado Fire ProtectionP.O. Box 11474Palm Desert Ca 92255760-574-6512C-16 # 1068664 As indicated 11/23/2020 10:42:33 AMFP-1 Sprinkler T.I. Plan 1st Floor Project Number 11-24-20 JA JC No. Description Date 1 Revision 1 Date 1 LOT 14ASIEGALL RESIDENCET.I.Madison ClubLa Quinta, Ca3/32" = 1'-0"1 1st Floor SPK Sprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 13 GL4906 Concealed Pendent Light Hazard Quick Response1/2 Orifice 3mm GB 4.9 1/2" 155 °F 6 GL4910 Recessed Pendent Light Hazard Quick Response1/2 Orifice 3mm GB 4.9 1/2" 200 °F : 19 Total No. of Sprinklers: 19 (E) OFFICE/ (E) BATH 3 (E) HALL (E) POWDER (E) CLO (E) DECK BEDROOM 3 BAR BAR COVERED DECK LIVING/ LOUNGE 2680 26802680 205ocsmt205ocsmt205ocsmt405ofixed 205ocsmt205ocsmt405ofixed 2680fr. dr. 2680pocket 2680 PR. 2650CSMT EXISTING DR.UNIT TO BERELOCATED PR. 268026802030CSMT.2030CSMT2030CSMT.2030CSMTLess Than 24 sf N N N N N N 1" PIPE UP FROM 1st FLOOR Less Than 55 sf Less Than 55 sf Less Than 55 sf Less Than 55 sf (N) BEDROOM 7 (N) BEDROOM 7 (N) BEDROOM 6 simon@silverado Scale Project number Date Drawn by Checked by Silverado Fire ProtectionP.O. Box 11474Palm Desert Ca 92255760-574-6512C-16 # 1068664 As indicated 11/23/2020 10:43:00 AMFP-2 Sprinkler Plan T.I. second Floor Project Number 11-24-20 JA JC No. Description Date 1/8" = 1'-0"1 2nd Floor SPK LOT 14ASIEGALL RESIDENCEMadison ClubLa Quinta, Ca. APRIL 2019 REV.A GFS-302 PAGE 1 of 4 SERIES GL-RES RESIDENTIAL PENDENT AND RECESSED PENDENT K-FACTOR: 3.0, 4.1, 4.9, 5.6 4077 Airpark Dr. Standish, MI 48658 • 989-846-4583 • www.globesprinkler.com Technical Support • 989-414-2600 • techservice@globesprinkler.com NOTE: Users should refer to Globe’s web site (www.globesprinkler.com) to assure that the most recent technical literature is being utilized. GENERAL DESCRIPTION The series GL-RES pendent sprinklers are decorative fast response glass bulb sprinklers specifically tested and List- ed for use in residential applications such as homes, apart- ments, hotels, and dormitories to provide control of these residential type fires and to improve the chance for occu- pants to escape. They utilize a 3mm frangible glass bulb as its heat sensing operating element. The recessed version of each of these Residential Sprinklers is intended for use in areas with finished ceilings. It employs a two-piece Re- cessed Escutcheon. The Recessed Escutcheon provides a total adjustment of 1/2 inch (12.7mm) from the flush ceiling position or ±1/4 inch (6.4mm) of recessed adjustment. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the pipe drops to the sprinklers must be cut. This sprinkler may be installed within dwelling occupancies as allowed by NFPA 13, 13D, 13R and any other related documents as appropriate. The GL3010 is typically utilized when maximum coverag- es are not needed, thereby reducing flow demands. The GL5610 is typically the sprinkler of choice when utilizing Residential Sprinklers within an NFPA 13 Occupancy. The larger K-factor can be advantageous when needed to con- form to the NFPA 13 hydraulic Special Design Approach for Residential Sprinklers. OPERATION Upon exposure to heat such as from a fire, the fluid in the bulb expands, compressing the air bubble within the bulb. When the air bubble can no longer compress, the fluid ex- pansion causes breakage of the glass bulb, resulting in re- lease of the water seat assembly, and discharge of water from the sprinkler. TECHNICAL DATA Approvals • See TABLE A Maximum Working Pressure • 175 psi (12 bar) Temperature Rating • See TABLE A K-Factor • GL3010 K3.0 gpm/psi½ (43.2 lpm/bar½) • GL4110 K4.1 gpm/psi½ (59.0 lpm/bar½) • GL4910 K4.9 gpm/psi½ (70.6 lpm/bar½) • GL5610 K5.6 gpm/psi½ (80.6 lpm/bar½) Thread Size • 1/2” NPT (15 mm) Length • 2-1/2” (6.3 cm) Materials of Construction • Frame - bronze • Deflector - brass • Screw - brass • Lodgement Wire (GL5610 only) - stainless steel • Bulb seat - copper • Spring - nickel alloy • Seal - teflon • Bulb - glass with alcohol based solution, 3mm • Escutcheon Assembly - carbon steel FINISHES AND ACCESSORIES Finishes • Factory Bronze • Chrome • White Polyester • Black Polyester - special order Escutcheons • Brass • Chrome • White Polyester • Black Polyester Wrenches • Standard • Recess • 1/2” NPT SERIES GL-RES GL3010, GL4110, GL4910, GL5610 SERIES GL-RES RESIDENTIAL PENDENT AND RECESSED PENDENT K-FACTOR: 3.0, 4.1, 4.9, 5.6 SERIES GL-RES RESIDENTIAL PENDENT AND RECESSED PENDENT K-FACTOR: 3.0, 4.1, 4.9, 5.6GFS-302 GFS-302 APRIL 2019 REV.A GFS-302 PAGE 2 of 4 DESIGN CRITERIA The Globe Residential Pendent Sprinkler Series GL-RES is cULus Listed for installation in accordance with this data sheet as well as the applicable installation Standard being utilized. Globe Residential Sprinkler Installation Guide When conditions exist that are outside the scope of the pro- vided criteria, refer to the Globe Residential Sprinkler Instal- lation Guide (Document GFS-380) for recommendations that may be acceptable to the authority having jurisdiction. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the min- imum required sprinkler flow rate is given in Table A for the coverage areas shown. The sprinkler flow rate is the min- imum required discharge from each of the total number of “design sprinklers” as specified in NFPA 13D or NFPA 13R. Hydraulic Design (NFPA 13) The minimum required discharge from each design area sprinkler shall be the greater of the following: (1) In accordance with minimum flow rates indicated in TABLE A. (2) In rooms or compartments greater than 800 ft2 (74.3 m2), calculated based on delivering a minimum of 0.1 gpm/ft2 (4.1 mm/min) over the coverage area of each sprinkler, calculated in accordance with the S x L Rules for density area sprinklers. (3) In rooms or compartments 800 ft2 (74.3 m2) or less (Defined as “Small Rooms”) calculated based on de- livering a minimum of 0.1 gpm/ft2 (4.1 mm/min) over the room or compartment using the area of the room divided by the number of sprinklers in the room. (7psi minimum) SIN K FACTOR GPM/PSI½ (lpm/bar½) TEMPERATURE MAX.AREA OF COVERAGE FEET (m) MINIMUM PRESSURE PSI (bar) MINIMUM FLOW GPM (L/min.) DEFLECTOR TO CEILING/ MOUNTING SURFACE DISTANCE INCHES (mm) MINIMUM DISTANCE BETWEEN SPRINKLERS FEET (m)155°F (68°C)175°F (79°C)200°F (93°C) GL3010 3.0 (43.2) cULus EU(1)cULus cULus 12 (3.6) x 12 (3.6)7.1 (.49)8.0 (30.3) Smooth Ceilings Recessed 1-1/8 (29) to 1-5/8 (41) Smooth Ceilings Exposed Max. 4 (101.6) Beamed Ceilings Adjacent per NFPA 13, 13D, or 13R as appropriate Beamed Ceilings In Beam 14” Max. Beam Depth 1-1/8 (29) to 1-5/8 (41) 8 (2.4) cULus EU(1)cULus cULus 14 (4.3) x 14 (4.3)11.1 (.765)10.0 (37.8) GL4110 4.1 (59) cULus EU(1)cULus EU(1)NA 12 (3.6) x 12 (3.6)7.2 (.5)11.0 (42) cULus EU(1)NA NA 14 (4.3) x 14 (4.3)8.6 (.59)12.0 (45) cULus EU(1)cULus NA 16 (4.9) x 16 (4.9)11.7 (.81)14.0 (53) GL4910 4.9 (70.6) cULus EU(1)cULus EU(1)NA 12 (3.6) x 12 (3.6)7.0 (.48)13.0 (49) cULus EU(1)cULus EU(1)NA 14 (4.3) x 14 (4.3)8.2 (.57)14.0 (53) cULus EU(1)cULus EU(1)NA 16 (4.9) x 16 (4.9)8.2 (.57)14.0 (53) cULus EU(1)cULus EU(1)NA 18 (5.5) x 18 (5.5)12.0 (.83)17.0 (64) cULus EU(1)cULus EU(1)NA 20 (6.1) x 20 (6.1)16.7 (1.15)20.0 (76) GL5610 5.6 (80.6) cULus NA NA 12 (3.6) x 12 (3.6)7.2 (.5)15.0 (57) cULus NA NA 16 (4.9) x 16 (4.9)11.5 (.79)19.0 (72) cULus NA NA 18 (5.5) x 18 (5.5)14.1 (.97)21.0 (79) cULus NA NA 20 (6.1) x 20 (6.1)18.4 (1.27)24.0 (91) TABLE A: NFPA 13, 13R, AND 13D HYDRAULIC AND INSTALLATION DESIGN CRITERIA (1)LISTED BY UNDERWRITERS LABORATORIES, INC. FOR USE IN THE U.S., CANADA, AND EUROPEAN UNION. NOTE: Deflector-to-Ceiling Distance Criteria reflects 2019 Edition of NFPA 13D and 13R. APRIL 2019 REV.A GFS-302 PAGE 3 of 4 4077 Airpark Dr. Standish, MI 48658 • 989-846-4583 • www.globesprinkler.com Technical Support • 989-414-2600 • techservice@globesprinkler.com NOTICE Do not install any bulb-type sprinkler if the bulb is cracked or there is loss of liquid from the bulb. Sprinklers should be tightened enough to obtain a leak-tight joint when water pressure is applied and/or hydrostatic test is performed. Sprinklers should not be overtightened as this can result in distortion and subsequent leak-age. It is recommended not to exceed 14 ft.-lb. (19.0 Nm) torque for 1/2 inch NPT sprinkler threads. Step1. Sprinklers must be properly oriented. Step2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprin- kler fitting. Note: Do not grasp the sprinkler by the deflector. Step3. Wrench-tighten the sprinkler using only the appropriate wrench. Wrenches are only to be applied to the sprinkler wrench flats or wrench hex as applicable. Note: Do not apply wrench to frame arms. INSTALLATION CARE AND MAINTENANCE Prior to installation, it is important to read and follow the “Sprinkler Caution” sheet (GFS-840) included within each box of sprinklers. This sheet is available on Globe’s web site (www.globesprinkler.com). Always obtain permission from the proper authorities to shut down the affected fire protection system and notify all personnel who may be affected by this action before closing a fire protection system main control valve for maintenance work on the system that it controls. Sprinklers should only be cleaned by means of gently dust- ing with a feather duster; otherwise, non-operation in the event of a fire or inadvertent operation may result. Store sprinklers in a cool, dry place. Exposure to extreme heat will damage the thermal sensing element, possibly re- sulting in premature activation. Avoid direct sunlight. Replace any sprinkler that shows any corrosion, damage, or loss of liquid from the glass bulb. Do not attempt to paint or alter the sprinkler’s coating in any manner after leaving the manufacturing plant. Do not attach wiring, ropes, decorations or fixtures to a sprinkler. Absence of an escutcheon, used to cover a ceiling hole, may delay sprinkler operation in a fire situation. It is the owner’s responsibility for inspection, testing and maintenance of the fire sprinkler system with all components and devices in accordance with the National Fire Protection Association Pamphlet 25 as well as any other requirements as set forth by the local Authority Having Jurisdiction (AHJ). FIGURE 1: STANDARD WRENCH P/N 325390 FIGURE 2: RECESSED WRENCH P/N 325391 FIGURE 3: 1/2” ADJUSTMENT RECESSED PENDENT APRIL 2019 REV.A GFS-302 PAGE 4 of 4 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). ORDERING INFORMATION SPECIFY: • WRENCH • Quantity • Part Number 1/2” NPT Standard . . . . . . . . . . . 325390 1/2” NPT Recess . . . . . . . . . . . . 325391 • Quantity • Part Number Cap . . . . . . . . . . . . . . . . . . . 327109-Cap • PROTECTIVE CAPS • SPRINKLER • ESCUTCHEON • Quantity • Finish • Part Number (See TABLE C) • Quantity • SIN • Temperature Rating • Finish • Part Number (See TABLE B) TABLE B: PART NUMBER SELECTION PART NUMBER SIN + TEMPERATURE + FINISH XXXX XXX XX SIN TEMPERATURE FINISH GL3010 3010 155 155°F (68°C)01 BRONZE GL4110 4110 175 175°F (79°C)02 CHROME GL4910 4910 200 200°F (93°C)03 WHITE POLYESTER GL5610 5610 04 BLACK POLYESTER Note: All combinations may not be available. Refer to TABLE A for available listed combinations 1/2" (13mm) ADJUSTABLE RECESSED ESCUTCHEON FINISH FRICTION FIT 1/2” NPT THREADED 1/2” NPT Chrome 332071 329301 White Polyester 332073-W 329303-W Brass 332072 NA Black Polyester 332073-B NA TABLE C: ESCUTCHEONS APRIL 2019 GFS-360 PAGE 1 of 4 SERIES GL-RES/INCH RESIDENTIAL ADJUSTABLE FLAT PLATE THE INCH® CONCEALED PENDENT K-FACTOR 4.9 TECHNICAL DATA Approvals •cULus - EU K-Factor •K4.9 gpm/psi½ (70.6 lpm/bar½) Temperature Rating •Sprinkler: 155°F (68°C) •Cover Plate: 135°F (57°C) Cover Plate Finishes •Chrome/White Painted (For painted plates other than white, contact Customer Service) Thread Size •1/2” NPT (15mm) Vertical Adjustment •1” (25mm) Nominal Maximum Working Pressure •175 psi (12 bar) Materials of Construction •Frame - bronze •• Screw - brass •Lodgement Wire - stainless steel • Bulb seat - copper •Spring - nickel alloy • •Bulb (3mm) - glass •Cover Plate - brass • Concealed Cup - carbon steel 4077 Airpark Dr.Standish, MI 48658 • 989-846-4583 • www.globesprinkler.com Technical Support • 989-414-2600 •techservice@globesprinkler.com NOTE: GENERAL DESCRIPTION The GL4906 Adjustable Flat Plate Concealed pendent sprinkler is a decorative fast response glass bulb sprinkler - tions such as homes, apartments, hotels, and dormitories to the chance for occupants to escape. The GL4906 utilizes a 3mm frangible glass bulb as its heat sensing operating ele- ment. While providing the optimal aesthetic appeal with the the largest vertical adjustment in the industry of a nominal 1”. This nominal 1” adjustment allows for previously unrec- dwelling occupancies as allowed by NFPA 13, 13D, 13R and any other related documents as appropriate. OPERATION The soldered cover plate drops off the retainer assembly which is connected to two guide pins, drops down below the ceiling into its intended position. As heat encompasses release of the water seat assembly, and discharge of water from the sprinkler. SERIES GL-RES/INCH GL4906 APRIL 2019 GFS-360 PAGE 2 of 4 1 1/4"MAX. 1/4"MIN.CEILING DESIGN CRITERIA The Globe Concealed Pendent Sprinkler (GL4906) is cULus Listed for installation in accordance with this data sheet as well as the applicable installation Standard being utilized. Globe Residential Sprinkler Installation Guide - vided criteria, refer to the Globe Residential Sprinkler Instal- lation Guide (Document GFS-380) for recommendations that may be acceptable to the authority having jurisdiction. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the mini- - imum required discharge from each of the total number of Hydraulic Design (NFPA 13) The minimum required discharge from each design area sprinkler shall be the greater of the following: (1) TABLE A. (2)In rooms or compartments greater than 800 ft2 (74.3 m2), calculated based on delivering a minimum of 0.1 gpm/ft2 (4.1 mm/min) over the coverage area of each sprinkler, calculated in accordance with the (3)In rooms or compartments 800 ft2 (74.3 m2) or less de- livering a minimum of 0.1 gpm/ft2 (4.1 mm/min) over the room or compartment using the area of the room divided by the number of sprinklers in the room.(7 psi minimum) FIGURE 1: GL4906 INSTALLED POSITION FIGURE 2: GL4906 ACTIVATED POSITION 3 5/16" DIA. 2 3/4" MAX. 1 7/8" MIN. 1/8"CEILING COVER PLATE SUPPORT SHELL CUP DEFLECTOR DROP PIN 1" x 1/2" REDUCER 2 3/8" DIA. CEILING 2 3/4" DIA. MIN. HOLE IN CEILING SIN STYLE MAX.AREA OF COVERAGE MINIMUM PRESSURE MINIMUM FLOW DEFLECTOR TO CEILING DISTANCE MINIMUM DISTANCE BETWEEN SPRINKLERS GL4906 THE INCH® ADJUSTABLE CONCEALED PENDENT 7.0 (.48)13 (49)Smooth Ceilings (When sprinkler is in activated position) Beamed Ceilings - Adjacent Allowed in ceiling. Beamed Ceilings - In Beam (When sprinkler is in activated position) 9 (2.7) 7.0 (.48)13 (49) 7.0 (.48)13 (49) 12.0 (.83)17 (64) 16.7 (1.15)20 (76) TABLE A: NFPA 13, 13R, AND 13D HYDRAULIC AND INSTALLATION DESIGN CRITERIA FOR GL4906 CONCEALED SPRINKLER NOTE: APRIL 2019 GFS-360 PAGE 3 of 4 CARE AND MAINTENANCE Step 1.Install pendent sprinklers in the pendent position, with the centerline of the sprinkler perpendicular to the mounting surface. Step 2.Remove the Protective Cap. Step 3.With pipe-thread sealant applied to the pipe threads, and using the Concealed Sprinkler Wrench P/N 332765 (FIGURE 6), install and tighten the Sprinkler/Concealed Cup Assembly Step 4.Replace the Protective Cap by pushing it upwards until it bottoms out against the Sup- port Cup. The Protective Cap helps prevent ceiling installation and/or during application of NOTICE: The system is considered Out of Service when Step 5.After the ceiling has been completed with the 2-3/4” (70mm) diameter hole, remove and discard the Protective Cap and verify that the does not move up and down freely, replace the entire sprinkler assembly. Do not attempt to modify or repair. Step 6.Push on the Cover Plate Assembly until its screw on the Cover Plate Assembly such that it lifts a ceiling panel out of its normal posi- tion. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover - ly to contact the ceiling, the Sprinkler Fitting must be repositioned. Always obtain permission from the proper authorities to personnel who may be affected by this action before closing work on the system that it controls. Sprinklers should only be cleaned by means of gently dusting with a feather dust- - tent operation may result. When properly installed, there is a nominal 1/8” (3mm) air gap between the Cover Plate and the ceiling (FIGURE 1). This air gap is necessary for proper operation of the sprin- above the Cover Plate to help assure appropriate release of be maintained and should never be sealed or caulked. Factory painted Cover Plates must not be repainted. In accordance with NFPA 25, Sprinklers which are found to replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. before, during, and after installation. Sprinklers damaged by dropping, striking, wrench slippage, or similar incidents, must be replaced. The owner is responsible for the inspection, testing, and compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (e.g. NFPA 25), in addition to the standards of any other authorities having jurisdiction. Refer to Globe’s Residential Installation Guide for further Care and Maintenance information. INSTALLATION FIGURE 3: HAND HELD INSTALLATION TOOL P/N 332875 FIGURE 4: INSTALLATION TOOL USED WITH EXTENSION P/N 332876 FIGURE 5: PROTECTIVE CAP P/N 332871 FIGURE 6: CONCEALED WRENCH P/N 332765 APRIL 2019 GFS-360 PAGE 4 of 4 ORDERING INFORMATION GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. List Terms and Conditions of Sale (Our Price List). 4077 Airpark Dr.Standish, MI 48658 • 989-846-4583 • www.globesprinkler.com Technical Support • 989-414-2600 •techservice@globesprinkler.com Sprinkler/Cup Assembly Specify: Qty. •P/N . . . . . . . . . . . . . . . . . . . . .GL490615501 Cover Plate Assembly Finish Specify: Qty. • P/N 135°F (57°C) Chrome . . . . . . . . . . . . . . .332891 135°F (57°C) White . . . . . . . . . . . . . . . .332892 Custom Painted: Contact Customer Service Sprinkler Wrench Specify: Qty. • P/N Concealed Wrench .................332765 The Inch Installation Tool Specify: Qty. • P/N Hand Held . . . . . . . . . . . . . . . . . . . . .332875 . . . . . . . . . . . . . . . .332876 Protective Caps Specify: Qty. •P/N . . . . . . . . . . . . . . . . . . . . .332871 82417 Priscilla Ct INDIO CA, 92201 C-16 #1068664 12/6/2021 www.silveradofire.com 760-600-0765 Info@silveradofire.com Re: FSS2020- 0157 81175 Elsworth Pl La Quinta, CA 92253 Good afternoon, our time to finish the project extended the time allowed by the permit. The reason being, the owners of the house were not in. They have returned and work has started back up. Please extend permit time, we are ready to proceed. Best regards, Simon Chavero Owner OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org December 8, 2020 Silverado Fire Protection 82417 Priscilla Ct Indio, CA 92201 Re: Residential (TI) Fire Sprinkler Plan Review – SIEGALL RESIDENCE (ADDITION) FSS2020-0157 / 81175 ELSWORTH PL, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 81175 ELSWORTH PL PERMIT#: FSS2020-0157 DATE ISSUED: 12/8/2020 DESCRIPTION: RESIDENTIAL TI – ADDITION CONTRACTOR: SILVERADO FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.