Loading...
FSS2020-0164ADDITIONAL SITES CHRONOLOGY CONDITION TYPE CONTACT DATE ADDED DATE REQUIRED DATE SATISFIED STATUS REMARKS NOTES CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL KOHL HETRICK 1/4/2021 1/4/2021 Contacted Kathy and requested the plans, calcs and water supply information as they were not attached. NOTE JOSE DELGADO 12/9/2021 CONTRACTOR REQUESTED FINAL INSPECTION. PERMIT EXPIRED AS OF 10/6/21 (6 MOS FROM DATE OF LAST APPROVED INSPECTION). ADDED EXTENSION FEE OF $83 AND EXTENDED PERMIT TO 12/*/21 SO CONTRACTOR CAN PAY FEE VIA ETRAKIT. WILL ALSO REQUIRE AN EXTENSION REQUEST LETTER FROM CONTRACTOR. OK TO EXTEND PER KOHL. NOTE KAYLI ALFORD 12/15/2020 12/15/2020 NO ATTACHMENTS UPLOADED - EMAILED CONTRACTOR TO SUBMIT ATTACHMENTS. CONDITIONS Description: RESIDENCE CLUB / FIRE SPRINKLER / BRES2019-0382 Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 12/15/2020 ECON Parcel No: 775380072 Site Address: 80165 NORTH RESIDENCE CLUB DR LA QUINTA,CA 92253 Approved: 1/4/2021 KHET Subdivision: TR 31627 AMEND Block: Lot: 18 Issued: 1/6/2021 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 12/16/2021 KHET Valuation: $12,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Friday, February 24, 2023 1:21:56 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0164 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT J D MECHANICAL FIRE INC 82579 FLEMING WAY SUITE D INDIO CA 92201 (760)775-6220 KATHY@JDMECHANIC AL.CO BILL TO JD MECHANICAL FIRE INC.82579 Fleming Way, Suite D Indio CA 92201 (760)775-6220 kathy@jdmechanical.c o CONTRACTOR J D MECHANICAL FIRE INC 82579 FLEMING WAY SUITE D INDIO CA 92201 (760)775-6220 KATHY@JDMECHANIC AL.CO OWNER NADADOR 54500 W RESIDENCE CLUB DR LA QUINTA CA 92201 (760)775-6220 kathy@jdmechanical.c o READY TO ISSUE CHECKLIST KAYLI ALFORD 12/15/2020 PENDING FEES DUE FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $161.00 $161.00 1/6/21 WEB7097 114751 CREDIT J D MECHANICAL FIRE INC ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $242.00 $242.00 1/6/21 WEB7097 114751 CREDIT J D MECHANICAL FIRE INC ECON FIRE STAFF - PER HOUR 101-0000-42420 1 $83.00 $83.00 12/16/21 R68292 44224 CHECK J D MECHANICAL inc AMA Total Paid for FIRE FEES: $486.00 $486.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 1/6/21 WEB7097 114751 CREDIT J D MECHANICAL FIRE INC ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 1/6/21 WEB7097 114751 CREDIT J D MECHANICAL FIRE INC ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$501.00 $501.00 Printed: Friday, February 24, 2023 1:21:56 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0164 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 12/16/2021 JOSE DELGADO Extension request letter.pdf Lot 18 res club to Kohl.pdf 0 DOC 1/4/2021 KOHL HETRICK FSS2020-0164 APPROVED PLANS AND CALCS.pdf FSS2020-0164 APPROVED PLANS AND CALCS.pdf 1 DOC 1/4/2021 KOHL HETRICK FSS2020-0164 COA AND JOB CARD.pdf FSS2020-0164 COA AND JOB CARD.pdf 1 BOND INFORMATION INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 4/5/2021 4/5/2021 APPROVED OVERHEAD HYRO KHET 4/5/2021 4/5/2021 APPROVED FIRE FINAL**KHET 12/16/2021 12/16/2021 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 12/15/2020 1/4/2021 1/4/2021 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 12/15/2020 12/16/2020 12/15/2020 PENDING DOCUMENTS NO DOCUMENTS ATTACHED PARENT PROJECTS Printed: Friday, February 24, 2023 1:21:56 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0164 FSS2020-0164 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs Res Club 18 Prescott, AZ 86301 Page 1 General Project Data Report General Data Project Title: Res Club 18 Project File Name: Res Club 18..fiw Designed By: Chad Ryan Date: November 10, 2010 Code Reference:Approving Agency: "F" FITTING = "T" RUN / B = ANGLE VALVE Client Name:Phone: Address:City, State Zip Code: Company Name:Representative: Company Address:City And State: Phone: Building Name: AREA 1 Building Owner: Contact at Building:Phone at Building: Address Of Building: 80165 Residence Club Dr City, State Zip Code: Project Data Description Of Hazard: Residential Sprinkler System Type: Wet Design Area Of Water Application: 392 ft² Maximum Area Per Sprinkler: 196 ft² Default Sprinkler K-Factor: 0.00 K Default Pipe Material: CPVC Inside Hose Stream Allowance: 0.00 gpm Outside Hose Stream Allowance: 0.00 gpm In Rack Sprinkler Allowance: 0.00 gpm Sprinkler Specifications Make:SENJU Model:8261 Size:7/16 Temperature Rating: 162 F Water Supply Test Data Source Of Information: Test Hydrant ID:Date Of Test: Hydrant Elevation: 0 ft Static Pressure: 69.30 psi Test Flow Rate: 29.80 gpm Test Residual Pressure: 42.20 psi Calculated System Flow Rate: 25.26 gpm Calculated Inflow Residual Pressure: 40.44 psi Available Residual Pressure At System Flow:49.34 psi Calculation Project Data Calculation Mode: Demand HMD Minimum Residual Pressure: 7.31 psi Minimum Desired Flow Density: 0.05 gpm/ft² Maximum Water Velocity: 0.00 ft/s Maximum Frictional Loss / 100 feet: 20.00 psi Number Of Active Nodes: 19 Number Of Active Pipes: 19 Number Of Inactive Pipes: 31 Number Of Active Sprinklers: 2 Number Of Inactive Sprinklers: 0 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs Res Club 18 Prescott, AZ 86301 Page 2 Fire Sprinkler Output Data Overall Pipe Output Data Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 1 3.70 12.00 10.00 7.31 0.75 10.00 0.05813 0.50 0.436 2 0.00 12.50 0.00 7.53 0.874 10.00 E 7.00 -0.217 CPVC 150 5.35 0 7.50 0.219 3 3.70 12.00 10.25 7.68 0.75 10.25 0.06089 0.50 0.457 4 0.00 12.50 0.00 7.92 0.874 10.25 E 7.00 -0.217 CPVC 150 5.48 0 7.50 0.240 2 0.00 12.50 0.00 7.53 0.75 0.00 0.05813 9.50 0.727 22 0.00 12.50 0.00 8.26 0.874 10.00 T 3.00 0.000 CPVC 150 5.35 0 12.50 0.727 4 0.00 12.50 0.00 7.92 0.75 0.00 0.06089 2.50 0.335 22 0.00 12.50 0.00 8.26 0.874 10.25 T 3.00 0.000 CPVC 150 5.48 0 5.50 0.335 22 0.00 12.50 0.00 8.26 0.75 0.00 0.21453 12.00 3.218 24 0.00 12.50 0.00 11.47 0.874 20.26 T 3.00 0.000 CPVC 150 10.83 0 15.00 3.218 6 0.00 10.50 0.00 13.77 0.75 0.00 0.00000 5.00 0.000 26 0.00 10.50 0.00 13.77 0.874 0.00 T 3.00 0.000 CPVC 150 0.00 0 8.00 0.000 24 0.00 12.50 0.00 11.47 0.75 9.14 0.04917 13.00 1.426 26 0.00 10.50 0.00 13.77 0.874 9.14 2F2E 16.00 0.866 CPVC 150 4.89 0 29.00 2.292 24 0.00 12.50 0.00 11.47 0.75 11.12 0.07074 43.00 6.084 28 0.00 12.50 0.00 17.56 0.874 11.12 5F5ET 43.00 0.000 CPVC 150 5.95 0 86.00 6.084 26 0.00 10.50 0.00 13.77 0.75 0.00 0.04920 37.50 2.878 30 0.00 9.50 0.00 17.08 0.874 9.14 4F2ET 21.00 0.433 CPVC 150 4.89 0 58.50 3.311 28 0.00 12.50 0.00 17.56 0.75 0.00 0.07074 40.50 4.421 32 0.00 10.50 0.00 22.85 0.874 11.12 5F2ET 22.00 0.866 CPVC 150 5.95 0 62.50 5.287 30 0.00 9.50 0.00 17.08 0.75 0.00 0.04920 36.50 3.468 34 0.00 9.50 0.00 20.55 0.874 9.14 3F4ET 34.00 0.000 CPVC 150 4.89 0 70.50 3.468 32 0.00 10.50 0.00 22.85 0.75 0.00 0.07074 19.00 1.769 36 0.00 9.50 0.00 25.05 0.874 11.12 3FT 6.00 0.433 CPVC 150 5.95 0 25.00 2.202 34 0.00 9.50 0.00 20.55 0.75 0.00 0.04920 40.50 4.501 36 0.00 9.50 0.00 25.05 0.874 9.14 6F6ET 51.00 0.000 CPVC 150 4.89 0 91.50 4.501 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs Res Club 18 Prescott, AZ 86301 Page 3 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 36 0.00 9.50 0.00 25.05 0.75 0.00 0.21459 11.00 3.863 75 0.00 9.50 0.00 28.91 0.874 20.26 E 7.00 0.000 CPVC 150 10.83 0 18.00 3.863 75 0.00 9.50 0.00 28.91 1.00 0.00 0.06971 4.50 0.523 100 0.00 5.00 0.00 31.38 1.101 20.26 3F 3.00 1.949 CPVC 150 6.83 0 7.50 2.471 100 FS 5.00 31.38 20.23 110 3.00 psi 5.00 34.38 110 0.00 5.00 0.00 34.38 1.00 0.00 0.09875 6.00 2.271 120 0.00 0.00 5.00 38.81 1.025 20.26 ETC 17.00 2.165 TYPE L COPPER TUBE 150 7.88 0 23.00 4.436 120 0.00 0.00 5.00 38.81 1.25 5.00 0.05331 4.00 0.704 130 0.00 -2.00 0.00 40.38 1.265 25.26 3EG 9.20 0.866 TYPE L COPPER TUBE 150 6.45 0 13.20 1.570 130 0.00 -2.00 0.00 40.38 2.00 0.00 0.00916 35.00 0.486 140 0.00 -1.00 0.00 40.44 1.816 25.26 2E 18.00 -0.433 HDPE 150 3.13 0 53.00 0.053 Fitting Legend: F = 45 Degree Elbow, E = 90 Degree Elbow, L = Long Turn Elbow, T = Tee or Cross, B = Butterfly Valve, G = Gate Valve, C = Check Valve Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs Res Club 18 Prescott, AZ 86301 Page 4 Fire Sprinkler Output Summary Hydraulically Most Demanding Sprinkler Node HMD Sprinkler Node Number:1 HMD Actual Residual Pressure:7.31 psi HMD Actual Flow:10.00 gpm Sprinkler Summary Sprinkler System Type:Wet Specified Area Of Application:392.00 ft² Minimum Desired Density:0.050 gpm/ft² Application Average Density:0.052 gpm/ft² Application Average Area Per Sprinkler: 196.00 ft² Sprinkler Flow:20.26 gpm Average Sprinkler Flow:10.13 gpm Flow Velocity And Imbalance Summary Maximum Flow Velocity ( In Pipe 36 - 75 ) 10.83 ft/sec Maximum Velocity Pressure ( In Pipe 36 - 75 ) 0.79 psi Allowable Maximum Nodal Pressure Imbalance: 0.0100 psi Actual Maximum Nodal Pressure Imbalance: 0.0090 psi Actual Average Nodal Pressure Imbalance: 0.0029 psi Actual Maximum Nodal Flow Imbalance: 0.0277 gpm Actual Average Nodal Flow Imbalance: 0.0032 gpm Overall Network Summary Number Of Unique Pipe Sections:19 Number Of Flowing Sprinklers:2 Pipe System Water Volume:8.68 gal Sprinkler Flow:20.26 gpm Non-Sprinkler Flow:5.00 gpm Minimum Required Residual Pressure At System Inflow Node: 40.44 psi Demand Flow At System Inflow Node: 25.26 gpm Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs Res Club 18 Prescott, AZ 86301 Page 5 Fire Sprinkler Output Data Hydraulic Supply/Demand Graph Pressure psiFlowrate(x100) gpm 69 42 0 0 10 20 30 40 50 60 70 80 90 100 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Supply Curve Data Static Pressure: 69.3 psi Test Residual Pressure: 42.2 psi Test Flow Rate: 29.8 gpm Demand Curve Data Calculated Residual Pressure: 40.44 psi Calculated Flow Rate: 25.26 gpm Excess Available Residual Pressure At Calculated Fl ow: 8.91 psi Pressure Required For First Sprinkler Downstream From Inflow Node To Flow: 0.00 psi Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs Res Club 18 Prescott, AZ 86301 Page 1 General Project Data Report General Data Project Title: Res Club 18 Project File Name: Res Club 18..fiw Designed By: Chad Ryan Date: November 10, 2010 Code Reference:Approving Agency: "F" FITTING = "T" RUN / B = ANGLE VALVE Client Name:Phone: Address:City, State Zip Code: Company Name:Representative: Company Address:City And State: Phone: Building Name: AREA 2 Building Owner: Contact at Building:Phone at Building: Address Of Building: 80165 Residence Club Dr City, State Zip Code: Project Data Description Of Hazard: Residential Sprinkler System Type: Wet Design Area Of Water Application: 324 ft² Maximum Area Per Sprinkler: 324 ft² Default Sprinkler K-Factor: 0.00 K Default Pipe Material: CPVC Inside Hose Stream Allowance: 0.00 gpm Outside Hose Stream Allowance: 0.00 gpm In Rack Sprinkler Allowance: 0.00 gpm Sprinkler Specifications Make:SENJU Model:8464 Size:7/16 Temperature Rating: 162 F Water Supply Test Data Source Of Information: Test Hydrant ID:Date Of Test: Hydrant Elevation: 0 ft Static Pressure: 69.30 psi Test Flow Rate: 29.80 gpm Test Residual Pressure: 42.20 psi Calculated System Flow Rate: 22.01 gpm Calculated Inflow Residual Pressure: 37.06 psi Available Residual Pressure At System Flow:53.83 psi Calculation Project Data Calculation Mode: Demand HMD Minimum Residual Pressure: 12.05 psi Minimum Desired Flow Density: 0.05 gpm/ft² Maximum Water Velocity: 0.00 ft/s Maximum Frictional Loss / 100 feet: 20.00 psi Number Of Active Nodes: 18 Number Of Active Pipes: 18 Number Of Inactive Pipes: 32 Number Of Active Sprinklers: 1 Number Of Inactive Sprinklers: 0 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs Res Club 18 Prescott, AZ 86301 Page 2 Fire Sprinkler Output Data Overall Pipe Output Data Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 2 0.00 12.50 0.00 14.68 0.75 0.00 0.00000 9.50 0.000 22 0.00 12.50 0.00 14.68 0.874 0.00 T 3.00 0.000 CPVC 150 0.00 0 12.50 0.000 4 0.00 12.50 0.00 14.68 0.75 0.00 0.00000 2.50 0.000 22 0.00 12.50 0.00 14.68 0.874 0.00 T 3.00 0.000 CPVC 150 0.00 0 5.50 0.000 5 4.90 10.00 17.01 12.05 0.75 17.01 0.15529 0.50 1.165 6 0.00 10.50 0.00 13.00 0.874 17.01 E 7.00 -0.217 CPVC 150 9.10 0 7.50 0.948 22 0.00 12.50 0.00 14.68 0.75 0.00 0.00000 12.00 0.000 24 0.00 12.50 0.00 14.68 0.874 0.00 T 3.00 0.000 CPVC 150 0.00 0 15.00 0.000 24 0.00 12.50 0.00 14.68 0.75 8.70 0.04492 13.00 1.303 26 0.00 10.50 0.00 14.24 0.874 8.70 2F2E 16.00 -0.866 CPVC 150 4.65 0 29.00 0.437 6 0.00 10.50 0.00 13.00 0.75 0.00 0.15529 5.00 1.242 26 0.00 10.50 0.00 14.24 0.874 17.01 T 3.00 0.000 CPVC 150 9.10 0 8.00 1.242 24 0.00 12.50 0.00 14.68 0.75 8.70 0.04492 43.00 3.864 28 0.00 12.50 0.00 18.54 0.874 8.70 5F5ET 43.00 0.000 CPVC 150 4.65 0 86.00 3.864 26 0.00 10.50 0.00 14.24 0.75 8.31 0.04126 37.50 2.414 30 0.00 9.50 0.00 17.09 0.874 8.31 4F2ET 21.00 0.433 CPVC 150 4.44 0 58.50 2.847 28 0.00 12.50 0.00 18.54 0.75 0.00 0.04492 40.50 2.808 32 0.00 10.50 0.00 22.21 0.874 8.70 5F2ET 22.00 0.866 CPVC 150 4.65 0 62.50 3.674 30 0.00 9.50 0.00 17.09 0.75 0.00 0.04126 36.50 2.909 34 0.00 9.50 0.00 20.00 0.874 8.31 3F4ET 34.00 0.000 CPVC 150 4.44 0 70.50 2.909 32 0.00 10.50 0.00 22.21 0.75 0.00 0.04492 19.00 1.123 36 0.00 9.50 0.00 23.77 0.874 8.70 3FT 6.00 0.433 CPVC 150 4.65 0 25.00 1.556 34 0.00 9.50 0.00 20.00 0.75 0.00 0.04126 40.50 3.775 36 0.00 9.50 0.00 23.77 0.874 8.31 6F6ET 51.00 0.000 CPVC 150 4.44 0 91.50 3.775 36 0.00 9.50 0.00 23.77 0.75 0.00 0.15529 11.00 2.795 75 0.00 9.50 0.00 26.57 0.874 17.01 E 7.00 0.000 CPVC 150 9.10 0 18.00 2.795 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs Res Club 18 Prescott, AZ 86301 Page 3 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 75 0.00 9.50 0.00 26.57 1.00 0.00 0.05044 4.50 0.378 100 0.00 5.00 0.00 28.89 1.101 17.01 3F 3.00 1.949 CPVC 150 5.73 0 7.50 2.327 100 FS 5.00 28.89 17.01 110 3.00 psi 5.00 31.90 110 0.00 5.00 0.00 31.90 1.00 0.00 0.07146 6.00 1.644 120 0.00 0.00 5.00 35.71 1.025 17.01 ETC 17.00 2.165 TYPE L COPPER TUBE 150 6.61 0 23.00 3.809 120 0.00 0.00 5.00 35.71 1.25 5.00 0.04132 4.00 0.545 130 0.00 -2.00 0.00 37.12 1.265 22.01 3EG 9.20 0.866 TYPE L COPPER TUBE 150 5.62 0 13.20 1.411 130 0.00 -2.00 0.00 37.12 2.00 0.00 0.00710 35.00 0.376 140 0.00 -1.00 0.00 37.06 1.816 22.01 2E 18.00 -0.433 HDPE 150 2.73 0 53.00 -0.057 Fitting Legend: F = 45 Degree Elbow, E = 90 Degree Elbow, L = Long Turn Elbow, T = Tee or Cross, B = Butterfly Valve, G = Gate Valve, C = Check Valve Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs Res Club 18 Prescott, AZ 86301 Page 4 Fire Sprinkler Output Summary Hydraulically Most Demanding Sprinkler Node HMD Sprinkler Node Number:5 HMD Actual Residual Pressure:12.05 psi HMD Actual Flow:17.01 gpm Sprinkler Summary Sprinkler System Type:Wet Specified Area Of Application:324.00 ft² Minimum Desired Density:0.050 gpm/ft² Application Average Density:0.052 gpm/ft² Application Average Area Per Sprinkler: 324.00 ft² Sprinkler Flow:17.01 gpm Average Sprinkler Flow:17.01 gpm Flow Velocity And Imbalance Summary Maximum Flow Velocity ( In Pipe 5 - 6 ) 9.10 ft/sec Maximum Velocity Pressure ( In Pipe 5 - 6 ) 0.56 psi Allowable Maximum Nodal Pressure Imbalance: 0.0100 psi Actual Maximum Nodal Pressure Imbalance: 0.0000 psi Actual Average Nodal Pressure Imbalance: 0.0000 psi Actual Maximum Nodal Flow Imbalance: -0.0015 gpm Actual Average Nodal Flow Imbalance: 0.0001 gpm Overall Network Summary Number Of Unique Pipe Sections:18 Number Of Flowing Sprinklers:1 Pipe System Water Volume:8.27 gal Sprinkler Flow:17.01 gpm Non-Sprinkler Flow:5.00 gpm Minimum Required Residual Pressure At System Inflow Node: 37.06 psi Demand Flow At System Inflow Node: 22.01 gpm Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs Res Club 18 Prescott, AZ 86301 Page 5 Fire Sprinkler Output Data Hydraulic Supply/Demand Graph Pressure psiFlowrate(x100) gpm 69 42 0 0 10 20 30 40 50 60 70 80 90 100 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Supply Curve Data Static Pressure: 69.3 psi Test Residual Pressure: 42.2 psi Test Flow Rate: 29.8 gpm Demand Curve Data Calculated Residual Pressure: 37.06 psi Calculated Flow Rate: 22.01 gpm Excess Available Residual Pressure At Calculated Fl ow: 16.77 psi Pressure Required For First Sprinkler Downstream From Inflow Node To Flow: 0.00 psi 82-579 Fleming Way, Suite D Indio, CA. 92201 760-775-6220 jd@jdmechanical.co License #1020141 December 15th, 2021 Re: 80165 North Residence Club Dr. To: Kohl Hetrick. This letter is to explain why lot 18 Residence Club has been delayed causing our fire permit to expire. Due to owner changes the construction schedule was extended. By: John D. Dover Pres. OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org January 4, 2021 JD Mechanical Fire Inc 82579 Fleming Way #D Indio, CA 92201 Re: Residential Fire Sprinkler Plan Review – RESIDENTIAL CLUB – LOT 18 FSS2020-0164 / 80165 NORTH RESIDENCE CLUB, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 80165 NORTH RESIDENCE CLUB PERMIT#: FSS2020-0164 DATE ISSUED: 1/4/2021 DESCRIPTION: LOT 18 CONTRACTOR: JD MECHANICAL FIRE INC HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.