Loading...
FSS2021-0027ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE JOSE DELGADO 9/27/2021 9/27/2021 CONTRACTOR REQUEST FINAL INSPECTION. PERMITED EXPIRED AS OF 8/28/21. (6 MOS FROM DATE OF LAST APPROVED INSPECTION. ADDED EXTENSION FEE OF $40.25 AND EXTEDED PERMIT TO 9/30/21 SO CONTRACTOR CAN PAY FEE VIA ETRAKIT. WILL ALSO REQUIRE AN EXTENSION REQUEST LETTER FROM CONTARACTOR. OK TO EXTEND PER KOHL. EXTENSION REQUEST LETTER RECEIVED. EXTENSION FEE PAID. EXTENDED PERMIT BY 6 MONTHS. CONDITIONS Description: O'KEEFE RESIDENCE / BRES2020-0115 Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 1/26/2021 ECON Parcel No: 767690033 Site Address: 52805 MERIWETHER WY LA QUINTA,CA 92253 Approved: 2/17/2021 KHET Subdivision: TR 33076-2 Block: Lot: 41 Issued: 2/25/2021 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 9/30/2021 KHET Valuation: $12,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Monday, February 27, 2023 1:25:18 PM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0027 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT DESERT FIRE EXTINGUISHER CO INC PO BOX 1607 PALM SPRINGS CA 92263 (760)322-0995 MARK@DESERT- FIRE.COM CONTRACTOR DESERT FIRE EXTINGUISHER CO INC PO BOX 1607 PALM SPRINGS CA 92263 (760)322-0995 MARK@DESERT- FIRE.COM OWNER TIMOTHY M O'KEEFE 1100 BELLEVUE WY BELLEVUE CA 98004 (760)322-0995 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD HYRO KHET 3/1/2021 3/1/2021 APPROVED FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $161.00 $161.00 2/25/21 WEB7486 095925 CREDIT DESERT FIRE EXTINGUISHER CO INC ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $242.00 $242.00 2/25/21 WEB7486 095925 CREDIT DESERT FIRE EXTINGUISHER CO INC ECON FIRE STAFF - PER HOUR 101-0000-42420 1 $40.25 $40.25 9/27/21 WEB9411 632673533 00 CREDIT 563921 ECON Total Paid for FIRE FEES: $443.25 $443.25 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 2/25/21 WEB7486 095925 CREDIT DESERT FIRE EXTINGUISHER CO INC ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 2/25/21 WEB7486 095925 CREDIT DESERT FIRE EXTINGUISHER CO INC ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$458.25 $458.25 Printed: Monday, February 27, 2023 1:25:18 PM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0027 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 1/26/2021 EtrakitContractor 1ST SUBMITTAL PLANS OKEEFE HOUSE PLAN.pdf 1 DOC 1/26/2021 EtrakitContractor 1ST SUBMITTAL CALCS OKEEFE HYD CALC.pdf 1 DOC 1/26/2021 EtrakitContractor 1ST SUBMITTAL HYDOR CALCS OKEEFE HYD GRAPH.pdf 1 DOC 1/26/2021 EtrakitContractor 1ST SUBMITTAL CUT SHEETS Residential Cut sheets.pdf 1 DOC 1/26/2021 EtrakitContractor 1ST SUBMITTAL STATIC PRESSURE Static Pressure.pdf 1 DOC 2/10/2021 EtrakitContractor Revised Plans Rev. OKEEFE HOUSE PLAN.pdf 1 DOC 2/10/2021 EtrakitContractor Revised Calcs Rev. OKEEFE HYD CALC.pdf 1 BOND INFORMATION OVERHEAD ROUGH PIPING KHET 3/1/2021 3/1/2021 APPROVED FIRE FINAL**KHET 9/30/2021 9/30/2021 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 1/26/2021 2/9/2021 2/9/2021 REVISIONS REQUIRED SEE ATTACHMENTS 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 1/26/2021 1/27/2021 1/28/2021 COMPLETE 2ND FIRE (1 WK)KOHL HETRICK 2/10/2021 2/19/2021 2/17/2021 APPROVED SEE ATTACHMENTS PARENT PROJECTS Printed: Monday, February 27, 2023 1:25:18 PM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0027 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 2/10/2021 EtrakitContractor Revised Hydro Graph Rev. OKEEFE HYD GRAPH.pdf 1 DOC 9/27/2021 Etrakit Contractor Extension on Fire Permit 52805 Meriwther Wy Residence Permit Letter Extension .pdf 1 DOC 2/9/2021 KOHL HETRICK FSS2021-0027 - 1ST PC - CORRECTIONS.pdf FSS2021-0027 - 1ST PC - CORRECTIONS.pdf 1 DOC 2/9/2021 KOHL HETRICK FSS2021-0027 - PLAN AND CALCS - CORRECTIONS.pdf FSS2021-0027 - PLAN AND CALCS - CORRECTIONS.pdf 1 DOC 2/17/2021 KOHL HETRICK FSS2021-0027 - APPROVED PLANS AND CALCS.pdf FSS2021-0027 - APPROVED PLANS AND CALCS.pdf 1 DOC 2/17/2021 KOHL HETRICK FSS2021-0027 - COA AND JOB CARD.pdf FSS2021-0027 - COA AND JOB CARD.pdf 1 DOC 3/1/2021 KOHL HETRICK FSS2021-0027 - 3-1-21 - REDLINES.pdf FSS2021-0027 - 3-1-21 - REDLINES.pdf 1 Printed: Monday, February 27, 2023 1:25:18 PM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0027 NO CLOSETS UNDER 24 SQ FT SHALL BE SPRINKLEREDNO BATHROOMS UNDER 55 SQ FT SHALL BE SPRINKLERED1" CITY WATER METERCONNECTION TO CITY1" PVC PIPE 50'-0"C-16# 563921“CPVC (ASTM F 442) pipe shall comply with theportions of the ASTM standards specified in NFPA 13D Table 5.2.2.2 that apply to thefire protection service. Not all pipe or tube made to ASTM F 442 or D 3309 are listed forfire sprinkler service. A copy of the listing shall be available at the job site.”“A list of CPVC compatible products, such as firecaulking, shall be provided at the job site for the inspectors review. ” All products thattouch CPVC piping shall be approved by the manufacturer. Please review productcompatibility guides. CRC 105.4.LOT 41B MADISON CLUBFSS2021-0027 Flow (gpm) I S P 20 40 60 80 100 120 140 100 150 200 250 300 350 400 450 500 Job OKEEFE RESIDENCE LOT 41 B MADISON CLUB LA QUINTA Remote Area: 1 Water Static Pres: Resid. Pres: Flow: Date: Loc: 75.0 60.0 500 psi psi gpm Required Pressure: Sys Flow: Sys+Hose: Safety Pres: Hd Elv Pres: 52.0 31 31 22.9 -1.7 psi gpm gpm psi psi Hose Allowance In: Out: 0 0 gpm gpm Supply OKEEFE RESIDENCE Drawing Date:2/9/21 2/10/21 8:27 HYDRAULIC DESIGN INFORMATION SHEET Job Name: OKEEFE RESIDENCE Location: LOT 41 B MADISON CLUB LA QUINTA, CA, 92253, US Drawing Date: 2/9/21 Remote Area Number: 1 Contractor: DESERT FIRE EXTINGUISHER Telephone: 760 322-0995 558 INDUSTRIAL PLACE PALM SPRINGS, CA 92264 Designer: AARON J Calculated By:SprinkCAD www.sprinkcad.com 1400 Pennbrook Pkwy. Lansdale, PA 19446 Construction: WOOD Occupancy:RESIDENTIAL Reviewing Authorities:LQ FD __________________________________________________________________________ SYSTEM DESIGN __________________________________________________________________________ Code:NFPA 13D Hazard:LIGHT System Type:WET __________________________________________________________________________ Area of Sprinkler Oper. 512 sq ft| Sprinkler or Nozzle Density (gpm/sq ft) RES | Make: TYCO Area per Sprinkler 256.0 sq ft| Model: TY3596 Hose Allowance Inside 0 gpm | K-Factor: 4.90 Hose Allowance Outside 0 gpm | Temperature Rating: 155 __________________________________________________________________________ CALCULATION SUMMARY 2 Flowing Outlets gpm Required: 31.2 psi Required: 52.0 @ City Supply __________________________________________________________________________ WATER SUPPLY __________________________________________________________________________ Water Flow Test | Pump Data | Date of Test | Rated Capacity 0 gpm | Static Pressure 75.0 psi | Rated Pressure 0.0 psi | Residual Pres 60.0 psi | Elevation 0 | At a Flow of 500 gpm | Make: | Elevation 0" | Model: | __________________________________________________________________________ Location: Source of Information: WATER AGENCY __________________________________________________________________________ SYSTEM VOLUME 35 Gallons __________________________________________________________________________ Notes: OKEEFE RESIDENCE Drawing Date:2/9/21 2/10/21 8:27 HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS QTY DESCRIPTION LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 1 26 28.0 psi 1 Pipe 1" 40x21 Allied Domestic 12' 120 1.049 26 2.6 1 1" Thrd 90 Ell DI 2' 120 1.049 26 0.5 1 1" Thrd Check Valve CSC "F18" 5' 120 1.049 26 1.1 Fixed Flow Flow Loss 5 gpm 3 1" CPVC 90 Ell 15' 120 1.049 31 5.6 1 Pipe 1" PVx15 BlazeMa Plastic 50' 150 1.101 31 7.7 1 1" Thrd Other Valve CITY "METER" CHART LOSS 31 5.0 1 1" Thrd Check Valve CSC "F18" 5' 120 1.049 31 1.5 ______ Total Loss for Underground 24.0 psi ______ Hydr Ref SRC Required at City Supply 31 52.0 psi Water Source 75.0 psi static, 60.0 psi residual @ 500 gpm 31 gpm 74.9 psi ======= SAFETY PRESSURE 22.9 psi Available Pressure of 74.9 psi Exceeds Required Pressure of 52.0 psi This is a safety margin of 22.9 psi or 31 % of Supply Maximum Water Velocity is 8.9 fps OKEEFE RESIDENCE Drawing Date:2/9/21 2/10/21 8:27 Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee V Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. __ K FACTOR Flow factor for open head or path where Flow (gpm) = K x -\/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf/ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0.433 x change in elevation Pf Friction loss (psi) to fitting where Pf = l x 4.52 x (Q/C)^1.85 / ID^4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x Q^2/ID^4 Pn Normal pressure (psi), where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations OKEEFE RESIDENCE Drawing Date:2/9/21 2/10/21 8:27 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K-FACTOR FLOW FLOW DENSITY (FT) (GPM/(PSI^½)) (PSI) (GPM) (GPM) (GPM/SQ.FT) 1 14.00 4.8 1S 8.00 4.90 7.1 13.1 13.1 0.05 2 14.00 5.0 2S 8.00 4.90 7.1 13.1 13.1 0.05 A1 12.00 11.6 W 12.00 28.0 Max velocity of 8.90 occurs in the pipe from A1 TO W Nodes with "S" indicate a node at the top of a sprig or bottom of drop pendent. The node without an "S" is on the branch. OKEEFE RESIDENCE Drawing Date:2/9/21 2/10/21 8:27 Tyco Fire Products Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 1 TO W (PRIMARY PATH) 13.06 1.101 1E 6.00 7.1 7.1 K = 4.90 1S C=150 3.83 -2.6 0.0 13.06 0.031 9.83 0.3 7.1 Vel = 4.44 1.101 7.41 4.8 4.8 EqK = 5.96 1 C=150 0.00 0.0 0.0 13.06 0.031 7.41 0.2 4.8 Vel = 4.44 13.10 1.101 1E 37.77 5.0 5.0 EqK = 5.84 2 C=150 1T 13.39 0.9 0.0 26.16 0.112 51.16 5.7 5.0 Vel = 8.90 1.101 1E 142.63 11.6 11.6 A1 C=150 3.83 0.0 0.0 26.16 0.112 146.46 16.4 11.6 Vel = 8.90 W 26.16 28.0 K = 4.94 13.10 1.101 1T 6.00 7.1 7.1 K = 4.90 2S C=150 9.56 -2.6 0.0 13.10 0.031 15.56 0.5 7.1 Vel = 4.46 2 13.10 5.0 K = 5.84 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) September 27, 2021 RE: Permit FSS2021-0027 / 52805 Meriwether Wy Desert Fire is requesting an extension on fire permit due to construction hold up. On permit # FSS2021-0027 / 52805 Meriwether Wy Any questions can be directed to Brittany Smith at Desert Fire 760-322-0995. Sincerely, Brittany Smith Executive Assistant Fire Sprinkler Manager, Desert Fire Extinguisher Co., Inc. 760-322-0995 P.O. Box 1607, Palm Springs, CA 92263 ▪ 760.322.0995 ▪ 760.325.7239 Fax 558 E. Industrial Place, Palm Springs, CA 92264 ▪ www.desert-fire.com ▪ info@desert-fire.com Email OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org February 17, 2021 Desert Fire Extinguisher PO Box 1607 Palm Springs, CA 92263 Re: Residential Fire Sprinkler Plan Review – O’KEEFE RESIDENCE FSS2021-0027 / 52805 MERIWETHER WAY, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 52805 MERIWETHER WAY PERMIT#: FSS2021-0027 DATE ISSUED: 2/17/2021 DESCRIPTION: O’KEEFE RESIDENCE CONTRACTOR: DESERT FIRE HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.