Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FSS2021-0042
ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT TCB INDUSTRIES LLC 11301 SUNSET AVE BANNING CA 92220 (909)709-4522 ashley@tcbindus.com CONTRACTOR TCB INDUSTRIES LLC 11301 SUNSET AVE BANNING CA 92220 (909)709-4522 ashley@tcbindus.com OWNER CM CORP 27075 CABOT RD. STE #114 LAGUNA HILLS CA 92653 (909)709-4522 CMICKELSON@CMCOR P.COM CONDITION TYPE CONTACT DATE ADDED DATE REQUIRED DATE SATISFIED STATUS REMARKS NOTES READY TO ISSUE CHECKLIST AARON HICKSON 2/25/2021 PENDING CONTRACTOR BL IS RENEWED. CONDITIONS Description: Adjustment for New Demising Wall / BCOM2020-0037 Type: FIRE SPRINKLER (WEB)Subtype: TENANT IMPROVEMENT Status: FINALED Applied: 2/24/2021 ECON Parcel No: 770020015 Site Address: 50929 WASHINGTON ST LA QUINTA,CA 92253 Approved: 3/10/2021 KHET Subdivision: PM 27984 Block: Lot: 1 Issued: 3/10/2021 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 7/19/2021 KHET Valuation: $6,500.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Scope of Work: Bring the entire building back to a Shell building. To achieve this goal, demo all existing pendant sprinklers and drops. Also demo all existing piping and appurtenances below mezzanines and stairs. Remaining fire protection shall be at the roof level only and in any areas that are existing and are to remain as is. FINANCIAL INFORMATION Printed: Monday, February 27, 2023 3:16:10 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0042 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD HYRO KHET 4/26/2021 4/26/2021 APPROVED OVERHEAD ROUGH PIPING KHET 4/26/2021 4/26/2021 APPROVED Requested an air-relief vent be installed in the highest portion of the system which would be the front tower. Need FDC/PIV painted. FIRE FINAL**KHET 7/19/2021 7/19/2021 APPROVED REVIEWS RETURNED PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS 101-0000-42420 0 $161.00 $161.00 3/10/21 WEB7602 03652G CREDIT TCB INDUSTRIES LLC ECON FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS PC 101-0000-42420 0 $242.00 $242.00 3/10/21 WEB7602 03652G CREDIT TCB INDUSTRIES LLC ECON Total Paid for FIRE FEES: $403.00 $403.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 3/10/21 WEB7602 03652G CREDIT TCB INDUSTRIES LLC ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 3/10/21 WEB7602 03652G CREDIT TCB INDUSTRIES LLC ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$418.00 $418.00 Printed: Monday, February 27, 2023 3:16:10 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0042 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 2/24/2021 EtrakitContractor 1ST SUBMITTAL PLANS La Quinta Village Anchor Building TI 02-20 -21[8403].pdf 1 DOC 2/24/2021 EtrakitContractor 1ST SUBMITTAL MATERIAL La Quinta Village Anchor Building TI Material Submittal [8404].pdf 1 DOC 3/10/2021 KOHL HETRICK FSS2021-0042 - APPROVED PLANS.pdf FSS2021-0042 - APPROVED PLANS.pdf 1 DOC 3/10/2021 KOHL HETRICK FSS2021-0042 - COA AND JOB CARD.pdf FSS2021-0042 - COA AND JOB CARD.pdf 1 BOND INFORMATION REVIEW TYPE REVIEWER SENT DATE DUE DATE DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 2/24/2021 3/10/2021 3/10/2021 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 2/24/2021 2/25/2021 2/25/2021 APPROVED- CONDITIONS Printed: Monday, February 27, 2023 3:16:10 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0042 FSS2021-0042 SPRINKLER PIPE CATALOG C O A S T TO COAST The best sprinkler pipe in the industry! ® Bull Moose Tube® is a customer focused, growth oriented manufacturer and marketer of tubular products, where success is based on a commitment to meeting the customer’s perception of quality. Our strength resides in our people working together to satisfy customers and to promote business growth by achieving superior financial performance. www.BullMooseTube.com sales@bullmoosetube.com 800.325.4467 SCHEDULE 10 SCHEDULE 40 EDDYTHREAD 40® EDDYLITE® EDDY FLOW® ULTRA EDDY® 2 Bull Moose Tube’s® “Eddy Pipe®” brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. EDDY PIPE® THE SUPERIOR SPRINKLER PIPE ADVANTAGES OF BULL MOOSE TUBE® EDDY PIPE® FAMILY • All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual. • Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. • All products are certified to ASTM A135 and A795 Type E, Grade A. • Available in specific cut to order lengths from regular mill rollings. • More popular sizes available with coating or bare. • Ultra Eddy®, Eddy Flow®, Eddylite®, and Eddythread 40® offer cost savings along with superior hydraulics without compromising service life. • Sprinkler pipe inventory stocked in Masury, Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent, Washington; and Dallas, Texas. • All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD II® MIC preventative coating. • Bull Moose Tube® sprinkler pipe is FBCTM compatible. PRODUCTS • Schedule 10 and Schedule 40: FM approved and UL listed sprinkler pipe. • Eddythread 40®: Light threadable Schedule 40 replacement with corrosion resistance ratio of 1.0. • Eddylite®: Lightwall threadable with standard outside diameter. • Eddy Flow®: Cost effective replacement for Schedule 10. • Ultra Eddy®: Lightwall roll groovable pipe. • Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM A123 standards. All products are stencilled to meet FM & UL specifications. PROTECTION • Eddy Guard II®: Bull Moose Tube® is producing product that can resist bacteriological growth even after multiple rinse-outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube® “Eddy Guard II®” and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard II® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull Moose Tube® reserves the right to change product specifications without notice and without incurring obligation.3 Bull Moose Tube’s® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube’s® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM A123 standards. All products are stencilled to meet FM & UL specifications. SCHEDULE 10 & SCHEDULE 40 FM APPROVED AND UL LISTED SPRINKLER PIPE I.D. (IN) WEIGHT/FT BUNDLE SIZE NOMINAL PIPE SIZE (IN) O.D. (IN) CRR** WATER FILLED WEIGHT 1819 Clarkson Road Chesterfield, MO 63017 Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masury, OH For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 www.bullmoosetube.com sales@bullmoosetube.com I.D. (IN) WEIGHT/FT BUNDLE SIZE NOMINAL PIPE SIZE (IN) O.D. (IN) 1 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 1-1/4 1.660 1.442 9.91 1.81 lbs/ft 2.518 61 1-1/2 1.900 1.682 7.76 2.09 lbs/ft 3.053 61 2 2.375 2.157 6.27 2.64 lbs/ft 4.223 37 2-1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 3 3.500 3.260 3.54 4.34 lbs/ft 7.957 19 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 1-1/4 1.660 1.380 1.00 2.27 lbs/ft 2.918 51 1-1/2 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 2 2.375 2.067 1.00 3.66 lbs/ft 5.114 30 2-1/2* 2.875 2.468 1.00 5.80 lbs/ft 7.875 30 3* 3.500 3.068 1.00 7.58 lbs/ft 10.783 19 4* 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 SCHEDULE 10 PIPE SPECIFICATIONS SCHEDULE 40 PIPE SPECIFICATIONS PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer’s instructions for the specific fitting used. CRR** WATER FILLED WEIGHT *Only available in Casa Grande, AZ **Corrosion Resistance Ratio per latest UL Directory Listing 4 Bull Moose Tube’s® Eddythread 40® is a lightweight replacement for Schedule 40 that has a Corrosion Resistance Ratio of 1. EDDYTHREAD 40® A LIGHTWEIGHT SCHEDULE 40 REPLACEMENT PIPE ADVANTAGES OF BULL MOOSE TUBE® EDDYTHREAD 40® • Has a Corrosion Resistance Ratio of 1.0. • Has a pressure rating of 300 psi. • Is lighter weight than Schedule 40. • Is approved by Factory Mutual and listed by Underwriters Laboratories. • Is produced in accordance to ASTM A135 and A795 Type E, Grade A. • Can be used with standard Schedule 40 threaded fittings, couplings, and valves. • Is produced from steel with excellent properties of strength and threadability. • Can be used in wet, preaction, and deluge type sprinkler systems. • Can be hot dipped galvanized to meet FM’s requirement for dry systems. • Offers lower freight costs. • Supplied with EDDY GUARD II® MIC preventative coating. 1819 Clarkson Road Chesterfield, MO 63017 Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masury, OH For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 www.bullmoosetube.com sales@bullmoosetube.com I.D. (IN) WEIGHT LB./FT BUNDLE SIZE NOMINAL PIPE SIZE (IN) O.D. (IN) CRR* WATER FILLED WEIGHT 1 1.295 1.083 1.00 1.461 1.860 70 1-1/4 1.650 1.418 1.00 2.070 2.754 51 1-1/2 1.900 1.654 1.00 2.547 3.468 44 2 2.375 2.123 1.00 3.308 4.842 30 EDDYTHREAD 40® SPECIFICATIONS PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer’s instructions for the specific fitting used. *Corrosion Resistance Ratio per latest UL Directory Listing 5 BMT - EDDY PIPE® SIZES AVAILABLE 1819 Clarkson Road Chesterfield, MO 63017 Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masury, OH For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 www.bullmoosetube.com sales@bullmoosetube.com O.D. (in) I.D. (in) Empty Weight (lb/ft) Water-Filled Weight (lb/ft) C.R.R. O.D. (in) I.D. (in) Empty Weight (lb/ft) Water-Filled Weight (lb/ft) C.R.R. O.D. (in) I.D. (in) Empty Weight (lb/ft) Water-Filled Weight (lb/ft) C.R.R. O.D. (in) I.D. (in) Empty Weight (lb/ft) Water-Filled Weight (lb/ft) C.R.R. O.D. (in) I.D. (in) Empty Weight (lb/ft) Water-Filled Weight (lb/ft) C.R.R. O.D. (in) I.D. (in) Empty Weight (lb/ft) Water-Filled Weight (lb/ft) C.R.R. ULTRA EDDY® EDDY FLOW® SCHEDULE 10 EDDYLITE® EDDYTHREAD 40® SCHEDULE 40 1.315 1.660 1.900 2.375 1.201 1.546 1.786 2.261 0.868 1.107 1.274 1.604 1.359 1.920 2.360 3.344 2.17 1.40 1.11 1.00 1.660 1.900 2.375 2.875 3.500 4.500 1.530 1.728 2.203 2.705 3.334 4.310 1.222 1.844 2.330 2.809 3.361 4.968 2.019 2.860 3.982 5.299 7.144 11.290 1.98 3.44 2.78 1.66 1.00 1.00 1.315 1.660 1.900 2.375 2.875 3.500 4.500 1.097 1.442 1.682 2.157 2.635 3.260 4.260 1.410 1.810 2.090 2.640 3.530 4.340 5.620 1.820 2.518 3.053 4.223 5.893 7.957 11.796 15.27 9.91 7.76 6.27 4.92 3.54 2.50 1.315 1.660 1.900 2.375 1.137 1.482 1.712 2.177 1.260 1.617 1.967 2.617 1.700 2.364 2.965 4.230 0.13 0.08 0.12 0.16 1.295 1.650 1.900 2.375 1.083 1.418 1.645 2.123 1.461 2.070 2.547 3.308 1.860 2.754 3.468 4.842 1.00 1.00 1.00 1.00 1.315 1.660 1.900 2.375 2.875 3.500 4.500 1.049 1.380 1.610 2.067 2.469 3.068 4.026 1.680 2.270 2.720 3.660 5.800 7.580 10.800 2.055 2.918 3.602 5.114 7.875 10.783 16.316 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1 1-1/4 1-1/2 2 2-1/2 3 4NPS (IN) 9 Ductile Iron Pipe Fittings • Manufacturing facilities are ISO 9001:2000 and ISO 14001 • Castings conform to ASTM A536 • Fitting dimensions conform to ASME B16.3 • Bushings and Plugs conform to ASME B16.14 • Ductile Iron Threaded Fittings are UL Listed and FM Approved at 500 psi • Fittings are 100% air tested • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical & physical properties Specifications SCI Quality Plus • Quality control inspections both at the overseas factory and our US warehouses • All fittings 100% tested under water • Company engineer available at your request • $10,000,000 product liability insurance • SCI trademark logo on each fitting • SCI 5/50 guarantee • Pro Pak System makes products easier to handle and warehouse • Orders shipped with in 24 hours • Fax confirmation of every order • Knowledgeable customer service personnel SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com SMITH-COOPER INTERNATIONAL (SCI) warrants to its initial purchaser only, that its products which are delivered to this initial purchaser will be of the kind described in the order or price list and will be free of defects in workmanship or material for a period of five years from the date of delivery to our initial purchaser. Should any failure to conform to this warranty appear within five years after the date of the initial delivery to our initial purchaser, SCI will, upon written notification thereof and substantiation that the goods have been stored, installed, maintained and operated in accordance with recognized engineering and piping practices and industry standards, correct such defects by suitable repair or replacement (which alternative shall be at the discretion of SCI) of product at SCI’s own expense upon return of the defective part to SCI. In the event that SCI elects to replace the defective product, SCI shall pay up to $50 per defective product for total cost of replacement. In the event of multiple claims, such payment shall be no greater than $1,000 for each installation project. This warranty applies only during normal use that meets the above referenced conditions of installation and operation and is absolutely void if the product has been damaged after purchase or if it has been misused, repaired, altered or modified in any manner whatsoever. SCI shall not warranty any of its products if any portion of the product including without limitation, any component, gasket, housing or bolt has been modified, altered, remanufactured or replaced in any manner by any customer, user of the product or third party. Correction of non-conformities, in the manner and for the period of time provided above, shall constitute fulfillment of all liabilities of SCI to our initial purchaser, with respect to the goods, whether based on contract, negligence, strict tort, or otherwise. It is the intention of SCI that no warranty of any kind, whether expressed or implied shall pass through our initial purchaser to any other person or corporation. No returns will be allowed unless prior written permission of SCI is first obtained. Buyers shall be responsible for all costs of transportation as well as a restocking charge. This warranty is exclusively for the benefit of the initial purchaser of this product from SCI and, except to the extent prohibited by applicable law, the foregoing warranty is in lieu of all other warranties, express or implied, including but not limited to warranties of fitness or merchantability. LIMITATIONS OF LIABILITY: SCI shall not under any circumstances be liable for special or consequential damages such as, but not limited to damage to loss of other property or equipment, loss of profits or revenue, cost of capital, cost of purchased or replacement goods, claims of customers of our initial purchaser, any labor cost for repair or replacement of the product or damage caused by the product. The remedies of our initial purchaser, and all others, set forth herein are exclusive, and the liability of SCI with respect to same shall not, except as expressly provided herein, exceed the price of the SCI products on which such liability is based. Warranty and Limitations of Liability ® UL/FM Class 300 Ductile Iron Threaded Fittings 90° Elbow 1/2 35E 3004 1.13 - - 0.218 100 200 3/4 35E 3006 1.31 - - 0.360 70 140 1 35E 3010 1.50 - - 0.575 40 80 1-1/4 35E 3012 1.75 - - 0.875 25 50 1-1/2 35E 3014 1.94 - - 1.159 18 36 2 35E 3020 2.25 - - 1.814 10 20 2-1/2 35E 3024 2.70 - - 3.233 4 8 90° Reducing Elbow 3/4x1/2 35RE3006004 1.22 1.20 - 0.294 80 160 1x1/2 35RE3001004 1.36 1.26 - 0.417 70 140 1x3/4 35RE3001006 1.45 1.38 - 0.475 50 100 1-1/4x1/2 35RE3012004 1.53 1.34 - 0.539 35 70 1-1/4x3/4 35RE3012006 1.63 1.45 - 0.6224 35 70 1-1/4x1 35RE3012010 1.67 1.58 - 0.735 30 60 1-1/2x1/2 35RE3014004 1.75 1.52 - 0.656 30 60 1-1/2x3/4 35RE3014006 1.75 1.52 - 0.745 25 50 1-1/2x1 35RE3014010 1.80 1.65 - 0.877 20 40 1-1/2x1-1/4 35RE3014012 1.88 1.82 - 1.029 18 36 2x1/2 35RE3020004 1.97 1.60 - 1.035 18 36 2x3/4 35RE3020006 1.97 1.60 - 1.044 18 36 2x1 35RE3020010 2.02 1.73 - 1.285 16 32 2x1-1/4 35RE3020012 2.10 1.90 - 1.363 12 24 2x1-1/2 35RE3020014 2.16 2.02 - 1.510 10 20 2-1/2x1-1/2 35RE3024014 2.51 2.16 - 2.206 6 12 2-1/2x2 35RE3024020 2.60 2.39 - 2.551 6 12 45° Elbow 1/2 35F 3004 0.88 - - 0.201 150 300 3/4 35F 3006 0.98 - - 0.322 80 160 1 35F 3010 1.13 - - 0.505 40 80 1-1/4 35F 3012 1.29 - - 0.759 25 50 1-1/2 35F 3014 1.44 - - 1.004 20 40 2 35F 3020 1.69 - - 1.616 10 20 2-1/2 35F 3024 1.95 - - 2.772 4 8 Tee 1/2 35T 3004 1.13 - - 0.308 80 160 3/4 35T 3006 1.31 - - 0.502 30 60 1 35T 3010 1.50 - - 0.789 25 50 1-1/4 35T 3012 1.75 - - 1.192 10 20 1-1/2 35T 3014 1.94 - - 1.574 10 20 2 35T 3020 2.25 - - 2.433 6 12 2-1/2 35T 3024 2.70 - - 4.335 4 8 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com Part Size Part Number Dimensions (in)Weight (lb) Packaging A B C Inner Master Ductile Iron Threaded Fittings conform to ASTM A536, ASME B16.3 Class 300, ASME B16.14, ASME B1.20.1® 1 A A A A A A AA B UL/FM Class 300 Ductile Iron Threaded Fittings Reducing Tee 3/4x1/2 35RT3006004 1.20 1.20 1.22 0.433 60 120 1x1/2 35RT3010004 1.26 1.26 1.36 0.621 30 60 1x1/2x1 35RT3010004010 1.50 1.36 1.50 0.669 30 60 1x3/4 35RT3010006 1.38 1.38 1.45 0.6879 25 50 1x3/4x3/4 35RT3010006006 1.38 1.31 1.45 0.615 35 70 1x3/4x1 35RT3010006010 1.50 1.45 1.50 0.711 25 50 1-1/4x1/2 35RT3012004 1.34 1.34 1.53 0.838 20 40 1-1/4x1/2x1-1/4 35RT3012004012 1.75 1.53 1.75 0.950 25 50 1-1/4x3/4 35RT3012006 1.45 1.45 1.62 0.9255 15 30 1-1/4x3/4x1-1/4 35RT3012006012 1.75 1.62 1.75 1.003 20 40 1-1/4x1 35RT3012010 1.58 1.58 1.67 1.040 15 30 1-1/4x1x1/2 35RT3012010004 1.34 1.26 1.53 0.739 25 50 1-1/4x1x3/4 35RT3012010006 1.45 1.38 1.63 0.823 20 40 1-1/4x1x1 35RT3012010010 1.58 1.50 1.69 0.942 20 40 1-1/4x1x1-1/4 35RT3012010012 1.75 1.69 1.75 1.082 15 30 1-1/2x1/2 35RT3014004 1.41 1.41 1.66 1.046 16 32 1-1/2x1/2x1-1/4 35RT3014004012 1.81 1.56 1.88 1.149 24 48 1-1/2x1/2x1-1/2 35RT3014004014 1.94 1.66 1.94 1.237 12 24 1-1/2x3/4 35RT3014006 1.52 1.52 1.75 1.145 16 32 1-1/2x3/4x1-1/4 35RT3014006012 1.94 1.66 1.88 1.167 20 40 1-1/2x3/4x1-1/2 35RT3014006014 1.94 1.75 1.94 1.287 18 36 1-1/2x1 35RT3014010 1.65 1.65 1.80 1.275 12 24 1-1/2x1x1/2 35RT3014010004 1.44 1.25 1.69 0.898 20 40 1-1/2x1x3/4 35RT3014010006 1.50 1.44 1.75 0.9861 16 32 1-1/2x1x1 35RT3014010010 1.65 1.50 1.80 1.081 16 32 1-1/2x1x1-1/4 35RT3014010012 1.82 1.67 1.88 1.235 12 24 1-1/2x1x1-1/2 35RT3014010014 1.94 1.80 1.94 1.349 12 24 1-1/2x1-1/4 35RT3014012 1.82 1.82 1.88 1.430 12 24 1-1/2x1-1/4x1/2 35RT3014012004 1.41 1.34 1.66 0.957 16 32 1-1/2x1-1/4x3/4 35RT3014012006 1.52 1.45 1.75 1.037 16 32 1-1/2x1-1/4x1 35RT3014012010 1.65 1.58 1.80 1.168 16 32 1-1/2x1-1/4x1-1/4 35RT3014012012 1.82 1.75 1.88 1.325 14 28 1-1/2x1-1/4x1-1/2 35RT3014012014 1.94 1.88 1.94 1.449 14 28 2x1/2 35RT3020004 1.49 1.49 1.88 1.529 10 20 2x3/4 35RT3020006 1.60 1.60 1.97 1.629 10 20 2x1 35RT3020010 1.73 1.73 2.02 1.780 8 16 2x1x2 35RT3020010020 2.25 2.02 2.25 1.998 8 16 2x1-1/4 35RT3020012 1.90 1.90 2.10 1.975 8 16 2x1-1/4x2 35RT3020012020 2.25 2.10 2.25 2.097 8 16 2x1-1/2 35RT3020014 2.02 2.02 2.16 2.122 8 16 2x1-1/2x1/2 35RT3020014004 1.49 1.41 1.88 1.321 10 20 2x1-1/2x3/4 35RT3020014006 1.60 1.52 1.97 1.408 10 20 2x1-1/2x1 35RT3020014010 1.73 1.65 2.02 1.568 8 16 2x1-1/2x1-1/4 35RT3020014012 1.90 1.82 2.10 1.717 8 16 2x1-1/2x1-1/2 35RT3020014014 2.02 1.94 2.16 1.8785 8 16 Bull Head Tee 3/4x1 35BT3006010 1.45 1.45 1.37 0.617 30 60 1x1-1/4 35BT3010012 1.67 1.67 1.58 0.941 20 40 1x1-1/2 35BT3010014 1.80 1.80 1.65 1.069 15 30 1-1/4x1x1-1/2 35BT3012010014 1.88 1.80 1.82 1.256 15 30 1-1/4x1-1/2 35BT3012014 1.88 1.88 1.82 1.338 15 30 1-1/4x2 35BT3012020 2.10 2.10 1.90 1.653 10 20 1-1/2x1-1/4x2 35BT3014012020 2.16 2.10 2.02 1.832 10 20 1-1/2x2 35BT3014020 2.16 2.16 2.02 1.888 8 16 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com Part Size Part Number Dimensions (in)Weight (lb) Packaging A B C Inner Master Ductile Iron Threaded Fittings conform to ASTM A536, ASME B16.3 Class 300, ASME B16.14, ASME B1.20.1® 2 A A B B C C UL/FM Class 300 Ductile Iron Threaded Fittings Cross 1 35X 3010 1.50 - - 0.947 20 40 1-1/4 35X 3012 1.75 - - 1.420 12 24 1-1/2 35X 3014 1.94 - - 1.866 8 16 2 35X 3020 2.25 - - 2.838 6 12 Reducing Cross 1-1/4x1 35RX3012010 1.67 1.58 - 1.204 15 30 1-1/2x1 35RX3014010 1.80 1.65 - 1.435 12 24 2x1 35RX3020010 2.02 1.73 - 2.000 8 16 Cap 1/2 35C 3004 0.87 - - 0.112 300 600 3/4 35C 3006 0.97 - - 0.177 200 400 1 35C 3010 1.16 - - 0.296 110 220 1-1/4 35C 3012 1.28 - - 0.439 70 140 1-1/2 35C 3014 1.33 - - 0.553 50 100 2 35C 3020 1.45 - - 0.852 25 50 2-1/2 35C 3024 1.70 - - 1.604 18 36 Union 1 35U 3010 2.19 - - 1.085 20 40 1-1/4 35U 3012 2.50 - - 1.250 15 30 1-1/2 35U 3014 2.62 - - 1.761 10 20 2 35U 3020 3.12 - - 2.441 6 12 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com Part Size Part Number Dimensions (in)Weight (lb) Packaging A B C Inner Master Ductile Iron Threaded Fittings conform to ASTM A536, ASME B16.3 Class 300, ASME B16.14, ASME B1.20.1® 3 A A A A A A A A B B UL/FM Class 300 Ductile Iron Threaded Fittings Coupling 1/2 35CP3004 1.38 - - 0.156 200 400 3/4 35CP3006 1.63 - - 0.254 100 200 1 35CP3010 1.75 - - 0.444 60 120 1-1/4 35CP3012 2.00 - - 0.553 35 70 1-1/2 35CP3014 2.19 - - 0.778 25 50 2 35CP3020 2.62 - - 1.211 15 30 2-1/2 35CP3024 3.00 - - 2.224 9 18 Hex Reducing Coupling 1x1/2 35RC3010004 1.69 - - 0.362 80 160 1x3/4 35RC3010006 1.69 - - 0.451 60 120 1-1/4x3/4 35RC3012006 2.06 - - 0.675 40 80 2x1 (not hex)35RC3020010 2.81 - - 1.094 20 40 Hex Bushing 1x1/2 35HB3010004 1.06 - - 0.224 180 360 1x3/4 35HB3010006 1.06 - - 0.180 180 360 1-1/4x1 35HB3012010 1.19 - - 0.296 90 180 1-1/2x1 35HB3014010 1.25 - - 0.464 75 150 1-1/2x1-1/4 35HB3014012 1.25 - - 0.314 75 150 2x1 35HB3020010 1.38 - - 0.651 40 80 2x1-1/4 35HB3020012 1.38 - - 0.657 40 80 2x1-1/2 35HB3020014 1.38 - - 0.657 40 80 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com Plug, Square Head 1/2 35SP3004 0.94 - - 0.077 600 1200 3/4 35SP3006 1.12 - - 0.131 350 700 1 35SP3010 1.25 - - 0.196 200 400 1-1/4 35SP3012 1.37 - - 0.316 100 200 1-1/2 35SP3014 1.44 - - 0.428 80 160 2 35SP3020 1.50 - - 0.667 45 90 Beam Clamp 3/8 35BC3003 0.75 - - 0.308 100 200 1/2 35BC3004 0.75 - - 0.555 80 160 Part Size Part Number Dimensions (in)Weight (lb) Packaging A B C Inner Master Ductile Iron Threaded Fittings conform to ASTM A536, ASME B16.3 Class 300, ASME B16.14, ASME B1.20.1® 4 A A A A A B B Notes SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com UL/FM Class 300 Ductile Iron Threaded Fittings Working Pressure Ratings TemperaTure Working pressure, nonshock psig Degrees F 300# class ThreaDeD FiTTings -20 To 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 5 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.Pipe Hangers Pipe Hangers 20 Fig. 200 - “Trimline” Adjustable Band Hanger (Cooper B-Line Fig. B3170NF) Fig. 200F - “Trimline” Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B3170NFF) Fig. 200C - “Trimline” Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B3170NFC) Fig. 200S - “Trimline” Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2” (15mm)thru 8” (200mm)pipe Material:Steel, Pre-Galvanized to G90 specifications Function:For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: •(1/2” (15mm)thru 2” (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. • (2 1/2” (65mm)thru 8” (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals:Underwriters Laboratories listed (1/2” (15mm)thru 8” (200mm)) in the USA (UL)and Canada (cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM)(3/4” (20mm)thru 8” (200mm)). Conforms to Federal Specifications WW-H-171E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature:650°F (343°C) Finish:Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By:Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. A B Fig. 200-1 to 200-2 Fig. 200-21/2 to 200-8 Pipe Size Rod Size ABApprox. Wt./100 Part No.in. (mm)in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2"(15)3/8"-16 3 1/8"(79.4)25/8"(66.7)11 (5.0) 200-3/4 3/4"(20)3/8"-16 3 1/8"(79.4)21/2"(63.5)11 (5.0) 200-1 1"(25)3/8"-16 3 3/8"(85.7)25/8"(66.7)12 (5.5) 200-11/4 11/4"(32)3/8"-16 3 3/4"(94.0)27/8"(73.0)13 (5.9) 200-11/2 11/2"(40)3/8"-16 3 7/8"(98.4)27/8"(73.0)14 (6.4) 200-2 2"(50)3/8"-16 4 1/2"(114.3)3"(76.3)15 (6.9) 200-21/2 21/2"(65)3/8"-16 5 5/8"(142.9)41/8"(104.7)27 (12.3) 200-3 3"(75)3/8"-16 5 7/8"(149.1)4"(101.6)29 (13.3) 200-31/2 31/2"(90)3/8"-16 7 3/8"(187.3)51/4"(133.3)34 (15.6) 200-4 4"(100)3/8"-16 7 3/8"(187.3)5"(127.0)35 (16.0) 200-5 5"(125)1/2"-13 9 1/8"(231.8)61/4"(158.7)66 (30.2) 200-6 6"(150)1/2"-13 10 1/8"(257.2)63/4"(171.4)73 (33.4) 200-8 8"(200)1/2"-13 13 1/8"(333.4)83/4"(222.2)136 (62.3) Fig. 200-1/2. 200-3/4 Fig. 200C Fig. 200F Fig. 200 Fig. 200S All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Threaded Accessories Threaded Accessories88 Fig. B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) Fig. B3205L - Threaded Rod (right & left hand threads) Fig. ATR - All Threaded Rod (TOLCO Fig. 99 & Fig. 100) Size Range:3/8"-16 thru 3"-4 rod Material:Steel Function:Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature:750°F (399°C) Finish:Plain. Contact Cooper B-Line for alternative finishes and materials. Order By:Figure number, rod size, length and finish Size Range:3/8"-16 thru 11/2"-6 rod in 10’ (3.05m)lengths Material:Steel Maximum Temperature:750°F (399°C) Finish:Plain. Contact Cooper B-Line for alternative finishes and materials. Order By:Figure number, rod size, length and finish Note:Fig. 99 is cut to length all threaded rod. Fig. 100 is full length. A Thread Size TL TL Specify Length Standard Design Load Thread Size Thread Length TL 650°F (343°C)750°F (399°C) Part No.A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 x 'L'3/8"-16 2 1/2"(63.5)730 (3.25)572 (2.54) B3205-1/2 x 'L'1/2"-13 2 1/2"(63.5)1350 (6.00)1057 (4.70) B3205-5/8 x 'L'5/8"-11 2 1/2"(63.5)2160 (9.61)1692 (7.52) B3205-3/4 x 'L'3/4"-10 3"(76.2)3230 (14.37)2530 (11.25) B3205-7/8 x 'L'7/8"-9 3 1/2"(88.9)4480 (19.93)3508 (15.60) Part No. Threads Recommended Load Approx. Wt./100 Ft. & Size Per Inch Lbs. (kN)Lbs.(kg) ATR 1/4” x ‘L’ 20 240 (1.07)12 (5.44) ATR 3/8” x ‘L’ 16 730 (3.24)29 (13.15) ATR 1/2” x ‘L’ 13 1350 (6.00)53 (24.04) ATR 5/8” x ‘L’ 11 2160 (9.60)89 (40.37) ATR 3/4” x ‘L’ 10 3230 (14.37)123 (55.79) ATR 7/8” x ‘L’9 4480 (19.93)170 (77.11) For larger sizes consult full line pipe hanger catalog. For larger sizes consult full line pipe hanger catalog. Sammys® for Wood .......................................................................................................................... 4 Sidewinder® for Wood ....................................................................................................................... 5 Sammys Swivel Head™ for Wood ......................................................................................................5 Sammys® for Steel ............................................................................................................................ 6 Sidewinder® for Steel ........................................................................................................................ 7 Sammys Swivel Head™ for Steel .......................................................................................................7 Sammy X-Press® ...............................................................................................................................8 Sammy X-Press Sidewinder™ ............................................................................................................8 Sammy X-Press Swivel™ ...................................................................................................................9 Sammy X-Press It® Installation Tool ..................................................................................................9 Sammys® for Concrete ................................................................................................................... 10 Sidewinder® for Concrete ................................................................................................................10 Sammys Swivel Head™ for Concrete ................................................................................................11 Concrete/Wood Installation Kit ........................................................................................................ 11 Sammys Toggle™ ............................................................................................................................ 12 Ceiling Screws .................................................................................................................................12 Dektite® Pipe Flashing .....................................................................................................................13 Speedy Pole Tool™.......................................................................................................................... 13 Approvals and Listings ....................................................................................................................14 Special Notes ..................................................................................................................................15 TABLE OF CONTENTS Warranty • Disclaimer of Warranty Proper fastener connection design takes in to account where and how fasteners are used. Allowance for special characteristics in materials, differences in materials, differences in types of materials being joined, unique or unusual environmental service or installation conditions and the safety factors required by anticipating normal or short term loading conditions must be considered. Due to possible differences in specifications, applications, and interpretation of results, purchasers and specifiers must make their own evaluation of the products, to determine the suitability of these products for intended use. All warranties of Buildex products, expressed or implied, including the warranties of merchantabilty and fitness for particular purposes are specifically excluded except for the following: Buildex will repair or replace any product which, within twelve months after sale by Buildex or its distributors, is found by Buildex to be defective in material or workmanship - normal wear and tear accepted. This is the sole warranty of Buildex and the sole remedy available to distributor or buyer. Buildex shall not be liable for any injury, loss or damage, direct, indirect, or consequential, arising out of the use of, or the inability to use, any Buildex product. For the most up to date information, visit www.itwbuildex.com 3 To find a distributor near you, call 800-BUILDEX INSTALLATION STEPS - VERTICAL INTO CONCRETE: 1. Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2” with a hammer/rotary hammer drill set on impact mode. 2. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). 3. Insert the CST screw into the nut driver. 4. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. 5. The concrete screw is ready to receive 1/4”, 3/8”, 1/2”, or metric all thread rod or bolt stock. (#14SW red nut driver used with 1/2” screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode — doing so will destroy the pullout factor of the screw. INSTALLATION STEPS - HORIZONTAL INTO CONCRETE: 1. Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2” with a hammer/ rotary hammer drill set on impact mode. 2. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14SW (red) nut driver (p/n 8114910) into the opposite end. 3. Insert the SWC screw into the nut driver. 4. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. 5. The SWC screw is ready to receive 1/4”, 3/8” or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode — doing so will destroy the pullout factor of the fastener. INSTALLATION INSTRUCTIONS FOR CONCRETE SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. INSTALLATION STEPS - VERTICAL INTO WOOD & STEEL: 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 2. Insert the SAMMYS® into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. 3. Push the face of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. 4. The SAMMYS is now ready to receive 1/4”, 3/8”, 1/2” or metric all thread rod, bolt stock. (The 1/2” requires the #14SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximumpullout in purlin steel. INSTALLATION STEPS - HORIZONTAL INTO WOOD & STEEL: 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 2. Insert the SAMMYS into the #14SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. 3. When the nut driver spins freely on the SAMMYS, stop the drill and remove. 4. The unit is now ready to receive 1/4”, 3/8”, M10, M8 or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. INSTALLATION INSTRUCTIONS FOR WOOD & STEEL 4 For the most up to date information, visit www.itwbuildex.com Wood Flooring Wood Joist Double Sheetrock Ceiling Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Box Qty Case Qty VERTICAL MOUNT 1/4"8002957 GST 100 1/4 x 1"210 (7/16” OSB) 670 (3/4” Ply)25 125 1/4"8003957 GST 200 1/4 x 2"1760 (Fir)25 125 3/8"8007957 GST 10 1/4 x 1"210 (7/16” OSB) 670 (3/4” Ply)300 25 125 3/8"8008957 GST 20 1/4 x 2"1760 (Fir)850 1475 25 125 3/8"8068925 GST 20-SS 1/4 x 2"1760 (Fir)850 25 125 3/8"8009925 GST 25-380 3/8 x 2-1/2"2113 (Fir)1500 25 125 3/8"8010957 GST 30 1/4 x 3"2060 (Fir)1500 1475 25 125 3/8"8069925 GST 30-SS 1/4 x 3"2060 (Fir)25 125 1/2"8013925 GST 2 1/4 x 2"1760 (Fir)25 125 1/2"8015925 GST 3 1/4 x 3"2275 (Fir)25 125 Not less than 2” nominal width (1-1/2”) Not less than 3” nominal thickness (2-1/2”) (depth or side of vertical member) #14 Black Nut Driver Part # 8113910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. #14 SW Red Nut Driver Part # 8114910 Composite / Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for GST 25-380 . Tool available on page 11. For vertical use - install in center of lower face. Minimum 2” embedment into base material for NFPA 13 compliance. • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation costs. • Manufactured in the U.S.A. SAMMYS® FOR WOOD Application Product Features Watch a video demonstration atwww.itwbuildex.com SAMMYS® FOR WOOD - Vertical Application MANUFACTURED U.S.A. 5 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETENot less than 2” nominal width (1-1/2”) up to 3-1/2” pipe; not less than 3” (2-1/2”) nominal width 4” & 5” pipe Minimum 2-1/2” from bottom for branch lines. Minimum 3” from bot- tom for main lines. Exception: This requirement shall not apply to 2” or thicker nailing strips resting on top of steel beams. Floor Joist Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) Box Qty Case Qty HORIZONTAL MOUNT 1/4"8019957 SWG 200 1/4 x 2"1725 (Fir)25 125 3/8"8020957 SWG 10 1/4 x 1"622 (Fir)300 25 125 3/8"8021957 SWG 20 1/4 x 2"1725 (Fir)1050 25 125 3/8"8073925 SWG 20-SS 1/4 x 2"1725 (Fir)850 25 125 3/8"*8022925 SWG 25-380 3/8 x 2-1/2"2249 (Fir)1500 25 125 3/8"8023925 SWG 30 1/4 x 3"1884 (Fir)25 125#14 SW Red Nut Driver Part # 8114910 • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation costs. • Manufactured in the U.S.A. Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thickness Box Qty Case Qty SWIVEL MOUNT 3/8"8139957 SH-GST 20 1/4 x 2"1257 (Fir)1050 1475 25 125 3/8"*8269957 SH-GST/CST 20 5/16 x 1-3/4” 1903 Dim. Lumber 1406 @ 45°off vertical Dim. Lumber 1500 850 @ 45°25 125 1/2”8303957 SH-GST/CST 2.0 5/16 x 1-3/4” 903 Dim. Lumber 1406 @ 45°off vertical Dim. Lumber 25 125 #14 Black Nut DriverPart # 8113910 • Eliminates distortion of threaded rod. • Accommodates up to 3 ½” x 12 pitch roof. • Allows 17° deflection from vertical. • Saves time from traditional methods. • Reduces installation costs. • Manufactured in the U.S.A. Application Product Features Application Product Features Composite / Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for Model SWG 25-380. Tool available on page 11. Watch a video demonstration atwww.itwbuildex.com SIDEWINDER® FOR WOOD - Horizontal Application SAMMYS SWIVEL HEAD™ FOR WOOD - Swivel Application #14 SH Orange Nut DriverPart # 8273910 * May require pre-drilling; consult joist manufacturer. * May require pre-drilling; consult joist manufacturer. 6 For the most up to date information, visit www.itwbuildex.com Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thick Max Thick Box Qty Case Qty VERTICAL MOUNT 1/4"8024957 DSTR 100 *1/4-20 x 1" TEKS 3 1510 (20 ga.).036"-20 ga 3/16"25 125 1/4"8025957 DST 100 1/4-14 x 1" TEKS 3 446 (20 ga.).036"-20 ga 3/16"25 125 1/4"8026957 DST 150 1/4-14 x 1-1/2" TEKS 3 970 (16 ga.).036"-20 ga 3/16"25 125 1/4"8027957 DST 200 1/4-14 x 2" TEKS 3 446 (20 ga.).036”-20 ga 3/16”25 125 1/4"8030957 TEK 500 12-24 x 1-1/2" TEKS 5 3125 (3/16").188”-3/16”1/2"25 125 3/8"8038957 DSTR 1 *1/4-20 x 1" TEKS 3 1510 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8037957 DSTR 1-1/2 *12-24 x 1-1/2" TEKS 5 1510 (3/16")1500 1475 .060”-16 ga.1/2"25 125 3/8"8039957 DSTR 516 *5/16-18 x 1-1/4" TEKS 3 2200 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8040957 DST 10 1/4-14 x 1" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8077925 DST 10-SS 1/4-14 x 1" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8041957 DST 15 1/4-14 x 1-1/2" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8078925 DST 15-SS 1/4-14 x 1-1/2" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8042957 DST 20 1/4-14 x 2” TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8044957 DST 30 1/4-14 x 3" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8045957 DST 516 5/16-18 x 1-1/4" TEKS 3 1500 (3/16")1500 1475 .125"-1/8"3/16"25 125 3/8"8046957 TEK 50 12-24 x 1-1/2" TEKS 5 3125 (3/16")1500 1475 .250”-1/4”1/2"25 125 1/2"8031925 DST 2.0 1/4-14 x 2" TEKS 3 446 (20 ga.) 970 (16 ga.).188"-3/16"1/4"25 125 1/2"8033925 DSTR 1.0 *1/4-20 x 1" TEKS 3 1510 (20 ga.).036"-20 ga 3/16"25 125 1/2"8034925 DSTR 5.16 *5/16-18 x 1-1/4" TEKS 3 2220 (20 ga.).036"-20 ga 3/16"25 125 1/2"8035925 DST 5.16 5/16-18 x 1-1/4" TEKS 3 1500 (3/16").125"-1/8"3/16”25 125 1/2"8036925 TEK 5.0 12-24 x 1-1/2" TEKS 5 3125 (3/16").188"-3/16"1/2"25 125 #14 Black Nut Driver Part # 8113910 #14 SW Red Nut Driver Part # 8114910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. • Made with Teks® self-drilling fasteners - no pre-drilling required. • Installs into steel range from 20 gauge – 1/2” thicknesses. • Saves time from traditional methods. • Reduces installation costs. • Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. • A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. • Manufactured in the U.S.A. SAMMYS® FOR STEEL Watch a video demonstration atwww.itwbuildex.com Application Product Features SAMMYS® FOR STEEL - Vertical Application *Includes retaining nut MANUFACTURED U.S.A. 7 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETEApprovals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thick Max Thick Box Qty Case Qty SWIVEL MOUNT 3/8"8137957 SH-DSTR 1*1/4-20 X 1” TEKS 3 3220 (3/16”)1500 1475 .035”3/16”25 125 3/8"8268957 SH-TEK 50 12-24 x 1-3/4" TEKS 5 2368 (1/2" steel Vertical) 1306 (45° off Vertical) 2281 (3/16” HSS) 1585 (3/16” HSS 45° off Vertical) 1500 (Vertical) 850 (45° off Vertical) 4" 2-1/2” 3/16"1/2"25 125 1/2”8270957 SH-TEK 5.0 12-24 x 1-3/4” TEKS 5 2368 (1/2” steel Vertical) 1306 (45° off Vertical) 2281 (3/16” HSS) 1585 (3/16” HSS 45° off Vertical) 3/16"1/2"25 125 #14 Black Nut DriverPart # 8113910 Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thickness Max Thickness Box Qty Case Qty HORIZONTAL MOUNT 1/4"8047957 SWD 100 1/4-14 x 1" TEKS 3 1477 (16 ga.).060"-16 ga 3/16"25 125 1/4"8049957 SWDR 100 *1/4-20 x 1" TEKS 3 1900 (20 ga.).036"-20 ga 3/16"25 125 3/8"8050957 SWD 10 1/4-14 x 1" TEKS 3 1477 (16 ga.).060"-16 ga 3/16"25 125 3/8"8080925 SWD 10-SS 1/4-14 x 1" TEKS 3 1477 (16 ga.).060"-16 ga 3/16"25 125 3/8"8052957 SWD 20 1/4-14 x 2" TEKS 3 1477 (16 ga.).060"-16 ga 3/16”25 125 3/8"8055957 SWDR 1 *1/4-20 x 1" TEKS 3 1900 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8054957 SWDR 1-1/2 *12-24 x 1-1/2" TEKS 5 2375 (3/16")1500 1475 .188"-3/16"1/2"25 125 3/8"8056957 SWDR 516 *5/16-18 x 1-1/4" TEKS 3 2480 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8057957 SWT 15 12-24 x 1-1/2" TEKS 5 2375 (3/16").188"-3/16"1/2"25 125 #14 SW Red Nut Driver Part # 8114910 *Includes retaining nut • Made with Teks® self-drilling fasteners - no pre-drilling required. • Installs into steel range from 20 gauge – 1/2” thicknesses. • A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. • Saves time from traditional methods. • Reduces installation costs. • Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. • Manufactured in the U.S.A. • Eliminates distortion of threaded rod in sloped roof applications. • Accommodates 3-1/2 x 12 pitch. • Installs into angled z-purlin; allows threaded rod to hang plumb. • Allows 17° deflection from vertical. • Manufactured in the U.S.A. *Does not comply with ROHS requirements / Includes retaining nut Application Product Features SAMMYS SWIVEL HEAD™ FOR STEEL - Swivel Application SIDEWINDER® FOR STEEL - Horizontal Application Application Product Features #14 SH Orange Nut DriverPart # 8273910 Watch a video demonstration atwww.itwbuildex.com Watch a video demonstration atwww.itwbuildex.com 8 For the most up to date information, visit www.itwbuildex.com SAMMY X-PRESS® - Vertical Application Approvals Rod Size Part Number Model Description Ultimate Pullout (lbs) UL Test Load (lbs) UL Min Thick FM Test Load (lbs) FM Min Thick Max Thick Box Qty Case Qty Application VERTICAL MOUNT 1/4"8181922 XP 200 Sammy X-Press 200 1146 (22 ga)185 (Luminaire) 250 (Luminaire) .027" .056”.125”25 125 Metal Deck 3/8"8150922 XP 20 Sammy X-Press 20 1146 (22 ga) 850 (2½" Pipe) 185 (Luminaire) 250 (Luminaire) 283 (Conduit & Cable) .027" .027” .056” .029” 940 (2" Pipe) 1475 (4” Pipe) .029” .104” .125”25 125 Metal Deck 3/8"8153922 XP 35 Sammy X-Press 35 1783 (16 ga) 1500 (4" Pipe) 185 (Luminaire) 250 (Luminaire) 416 (Conduit & Cable) .060” .029” .056” .059” 940 (2" Pipe) 1475 (4” Pipe) .029” .104”.125”25 125 Purlin 3/8"8150922 XP 20 Sammy X-Press 20 1146 (22 ga)850 (2½ Pipe) Pre-Pour Structural Concrete@ 3000 psi Post-Pour Range II LWC≤ 35 PCF (lbs/ft³) 25 125 Metal Deck (Pre-Pour) Metal Deck (Post-Pour) SAMMY X-PRESS® Post-Pour Range II LWC≤ 35 PCF (lbs/ ft³) Pre-Pour Structural Concrete @ 3000 psi Installs into Metal Deck, Purlin, or Tubular Steel • The Sammy X-Press expands to provide direct vertical attachment in: - light gauge steel deck or purlin (22 ga. - 1/8”). • Installs in seconds with Sammy X-Press It® Tool, saving time & installation costs. • Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A. Watch a video demonstration atwww.itwbuildex.com Application Product Features • The Sammy X-Press Sidewinder expands to provide horizontal attachment in: - 16 ga - 3/16” steel - purlin, tubular steel. • Installs in seconds with Sammy X-Press It® Tool, saving time & installation costs. • Use in applications where access to the back of the installed fastener is prohibited; ie. metal roof deck, tubular steel, or vapor barrier fabric. • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A. (SWXP) Approvals Rod Size Part Number Model Description Ultimate Pullout (lbs) UL Test Load (lbs) UL Min Thick FM Test Load (lbs) Max Thick Box Qty Case Qty Application HORIZONTAL MOUNT 3/8"8293957 SWXP 35 Sidewinder X-Press 35 1798 (16 ga) 1250 (3½" Pipe) 80 (Luminaire) 416 (Conduit & Cable) .059”.125”25 125 Purlin Watch a video demonstration atwww.itwbuildex.com Application Product Features SAMMY X-PRESS SIDEWINDER™ - Horizontal Application (XP) MANUFACTURED U.S.A. 9 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETE• The Sammy X-Press Swivel allows you to hang plumb in extreme roof pitches: - 89° in z-purlin - 45° in metal deck for 12/12 pitch • Installs in seconds with Sammy X-Press It® Tool, saving time & installation costs. • Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A.(SXP) Installs into Metal Deck, Purlin, or Tubular Steel Approvals Rod Size Part Number Model Description Ultimate Pullout (lbs) UL Test Load (lbs) UL Min Thick FM Test Load (lbs) FM Min Thick Max Thick Box Qty Case Qty Application SWIVEL MOUNT 3/8”8294922 SXP 20 Swivel X-Press 20 1061 (22 ga Vert) 829 (45° Off Vert) 750 (2” Pipe) 170 Vertical (Luminaire) 80 @ 45° (Luminaire) 283 Vertical (Conduit & Cable) 233 @ 45° (Conduit & Cable) .029” 635 (2” Pipe).029”.125”25 125 Metal Deck 3/8"8295922 SXP 35 Swivel X-Press 35 1675 (16 ga Vert) 1558 (89° Off Vert) 1250 (3-1/2" Pipe) 250 Vertical (Luminaire) 80 @ 90° (Luminaire) 500 Vertical (Conduit & Cable) 333 @ 89° (Conduit & Cable) .059” 635 (2" Pipe).029”.125”25 125 Purlin 1/2”8272957 SXP 2.0 Swivel X-Press 2.0 1061 (22 ga Vert) 829 (45° Off Vert).027”.125”25 125 Metal Deck 1/2"8271957 SXP 3.5 Swivel X-Press 3.5 1675 (16 ga Vert) 1558 (89° Off Vert).060".125”25 125 Purlin • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A. Watch a video demonstration atwww.itwbuildex.com Application Product Features *Tool Includes: Sleeve, Bit Receiver, Hex Wrench, and 25/64” Drill Bit. Part Number Model Description Qty 8194910 UXPIT*Universal X-Press It Tool 1 8152910 XPDB 25/64" Drill Bit 1 SAMMY X-PRESS IT® Installation Tool • The Sammy X-Press expands to provide direct vertical attachment in: - metal deck (22-16 gauge) - z-purlin (18-16 gauge) • Manufactured in the U.S.A. Watch a video demonstration atwww.itwbuildex.com Application Product Features • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A. SAMMY X-PRESS SWIVEL™ - Swivel Application 10 For the most up to date information, visit www.itwbuildex.com SAMMYS® FOR CONCRETE - Vertical Application Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs)* FM Test Load (lbs) Box Qty Case Qty VERTICAL MOUNT 1/4"8058957 CST 200 5/16 x 1-3/4"2400 25 125 3/8"8059957 CST 20 5/16 x 1-3/4"2400 1475 25 125 3/8"8145925 CST 20-SS 5/16 x 1-3/4"2400 25 125 1/2"8060925 CST 2 5/16 x 1-3/4"2400 25 125 ICC-ESR 2202 3/8”8306957 CCST 516 5/16-14 x 2-1/2” 857**25 125 #14 BlackNut DriverPart # 8113910 #14SW Red Nut DriverPart # 8114910 • Easy two step process (Drill hole & drive Sammys concrete anchor). • ¼” pre-drilled pilot hole required. • Concrete Installation Tool available for a one tool installation process. • Manufactured in the U.S.A. • New Sammys for Cracked Concrete now available! * Tested in 3000 PSI concrete ** Pullout strength for Cracked Concrete and Seismic Zones A-F Application Product Features SAMMYS® FOR CONCRETE Watch a video demonstration atwww.itwbuildex.com SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs)* FM Test Load (lbs) Box Qty Case Qty HORIZONTAL MOUNT 1/4"8062957 SWC 200 5/16 x 1-3/4"2450 25 125 3/8"8061957 SWC 20 5/16 x 1-3/4"2450 1475 25 125 3/8”8307957 SW-CCST 516 5/16-14 x 2-1/2” 857**25 125#14SW Red Nut DriverPart # 8114910 • Easy two step process (Drill hole & drive Sammys concrete anchor). • ¼” pre-drilled pilot hole required. • Concrete Installation Tool available for a one tool installation process. • Manufactured in the U.S.A. • New Sammys for Cracked Concrete now available! * Tested in 3000 PSI concrete ** Pullout strength for cracked concrete and Seismic Zones A-F Application Product Features Watch a video demonstration atwww.itwbuildex.com SIDEWINDER® FOR CONCRETE - Horizontal Application MANUFACTURED U.S.A. For complete performance data see ICC Report ESR-2202 11 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETE(a) or (g)(d)(h) (b) (c) Rotary Hammer Drill into concrete Part Number Description Each Qty 8122910 Concrete Installation Kit (a) Kit includes the following items: 8113910 #14 Black Nut Driver (b)1 8114910 #14 SW Red Nut Driver (c)1 8116910 #250 Bit (1/4") (d)1 8117910 SDS Bit (1/4") (e)1 8118910 7/32 Wood Bit (f)1 8120910 HEX 250 Bit Receiver (1/4") (g)1 8098910 SL 250 Sleeve (h)1 8121910 SDS B250 Bit Receiver (1/4”)*1 *Only sold separately - not included in kit. or (e)(h) (b) (c) Hammer Drill into concrete Application CONCRETE / WOOD INSTALLATION KIT Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs)* Box Qty Case Qty SWIVEL MOUNT 3/8"8269957 SH-GST/CST 20 5/16 x 1-3/4" 2537 in 3000 psi concrete 1459 @ 45°off vertical in 3000 psi concrete 2852 in 6000 psi concrete 1636 @ 45°off vertical in 6000 psi concrete 25 125 1/2”8303957 SH-GST/CST 2.0 5/16 x 1-3/4" 2537 in 3000 psi concrete 1459 @ 45°off vertical in 3000 psi concrete 2852 in 6000 psi concrete 1636 @ 45°off vertical in 6000 psi concrete 25 125 3/8”8308957 SH-CCST 516 5/16-14 x 2-1/2”857**25 125 Application Product Features #14 SH Orange Nut DriverPart # 8273910 SAMMYS SWIVEL HEAD™ FOR CONCRETE - Swivel Application • Installs vertically and swivels up to 89° in wood & concrete structures. • Eliminates distortion of threaded rod. • 1/4” pre-drilled pilot hole required. • Concrete installation tool available for a one piece installation process. • Manufactured in the U.S.A. • New Sammys for Cracked Concrete now available! Note: UL Listed for wood - see page 5 * Tested in 3000 PSI concrete ** Pullout strength for cracked concrete and Seismic Zones A-F 12 For the most up to date information, visit www.itwbuildex.com Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs)Box Qty Case Qty 1/4"8063925 SST 300 1/4 x 3"450 (Lath & Plaster) 404 (2 Layers 5/8 Rock)25 125 3/8"8064925 SST 30 1/4 x 3"450 (Lath & Plaster) 404 (2 Layers 5/8 Rock)25 125#14 Black Nut DriverPart # 8113910 Pre-Cast Hollow Core Concrete 1. Pre-drill a 5/8” hole with a regular drill or hole saw. 2. Insert SST screw into #14 black nut driver. With wing nut and washer on bolt, insert wing nut through surface, and begin installation. 3. When bolt is secure and nut driver spins free, stop drill motor and remove. 4. SST screw is now ready to receive 1/4”, 3/8”, or Metric all thread rod or bolt stock. Approvals Substrate Part Number Model Point Description Overal Total Length Ultimate Pullout (lbs) Max Gauge ICC Test Load (lbs) Box Qty Case Qty ICC STEEL 8107957 CWSD 1*Teks 1/4 x 1"2”472 (20 ga)16 ga.170 (20 ga.)25 125 ICC STEEL WOOD 8190957 CWSD 15*Gimlet 1/4 x 1-1/2"2-3/4”472 (20 ga) 980 (Fir)20 ga.270 (20 ga.)25 125 ICC STEEL 8108957 CWSD 2*Teks 1/4 x 2"3-1/4”472 (20 ga)16 ga.170 (20 ga.)25 125 ICC 8110910 CWIT Installation Tool 1CWIT Installation ToolPart # 8110910 Use the Speedy Pole Tool™ for easy installation of ceiling screws without ladders or scaffolding! (see pg 13 for details) • 3/16” eyelet to accommodate common wire size. • ICC approvals can be found at www.itwbuildex.com under Evaluation Report # ER-5367. * Does not comply with ROHS requirements Application Installation Steps Application Product Features CEILING SCREWS SAMMYS TOGGLE™ ACCESSORIES To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETE13 • Complies with NFPA 13 Code Changes. • Flashing for dry pendant sprinklers subject to extreme temperature changes. • One piece construction is easy to install. • Pipe diameter markings ensure accurate fit. • EPDM temperature range of -65°F to +250°F. Part Number Description Pipe Outside Diameter Dektite Base Diameter Dektite Height Box Qty 4001910 Mini 1/4” - 1-1/8”3-1/2”1-3/4”20 4003910 1 1/4” - 2”4-3/4”3”10 4004910 2 1-3/4” - 3-1/4”6-1/4”4”10 DEKTITE® PIPE FLASHING Application Product Features • Speed your labor by 25% • Work from the ground up • No scaffolding, ladders, or lifts • Perfect for working in tight spaces, through ceiling grid, and high vaulted ceilings • Works with any Vertical SAMMYS: Wood, Steel, or Concrete Part Number Description Box Qty SP4 Speedy Pole 4’ - 12’1 SP6 Speedy Pole 6’-18’1 8128910 Ceiling Wire Socket Driver 1 SPEEDY POLE TOOL™ Installation Instructions Product Features Adjust the Pole Tool to length. The adjusting pin must be 18” below the base or the pin may interfere with the rod. Load rod and Sammys into Pole Tool.The socket will spin freewhen the screw is completely installed. Pull down to remove the Pole Tool. Insert adjustingpin here 1 2 3 For Ceiling Wire Applications Driver hangs 12 or 9 gauge wire or jack chain NEW DESIGN! NOW COMES FULLY ASSEMBLED Part Number Model Rod Size Mount Direction UL Max Pipe Size UL Test Load (lbs)UL Min Wood Thickness FM Max Pipe Size FM Test Load (lbs)FM Min Wood Thickness SAMMYS FOR WOOD - PIPE HANGER 8007957 GST 10 3/8”Vertical CPVC 1-1/2”300 1-1/2” 8020957 SWG 10 3/8”Horizontal CPVC 1-1/2”300 1-1/2” 8008957 GST 20 3/8”Vertical 2-1/2”850 1-1/2”4”1475 1-1/2” 8068925 GST 20-SS 3/8”Vertical 2-1/2”850 1-1/2” 8010957 GST 30 3/8”Vertical 4”1500 1-1/2”4”1475 1-1/2” 8009925 GST 25-380 3/8”Vertical 4”1500 1-1/2” 8022925 SWG 25-380 3/8”Horizontal 3-1/2” - 4”*1500 1-1/2” 8021957 SWG 20 3/8”Horizontal 2-1/2” - 3”**1050 1-1/2” 8073925 SWG 20-SS 3/8”Horizontal 2-1/2”850 1-1/2” 8269957 SH-GST/CST 20 3/8”45° Angle off Vertical 2-1/2”850 1-1/2” 8269957 SH-GST/CST 20 3/8”45° Angle off Vertical 4”1500 1-1/2” 8139957 SH-GST 20 3/8”17° Angle off Vertical 3”1050 1-1/2”4”1475 1-1/2” SAMMYS FOR STEEL - PIPE HANGER Min Steel Thick Max Steel Thick 8038957 DSTR 1 3/8”Vertical 4”1500 .035”4”1475 .105” 8037957 DSTR 1-1/2 3/8” Vertical 4”1500 .035”4”1475 .105” 8039957 DSTR 516 3/8”Vertical 4”1500 .037”4”1475 .105” 8045957 DST 516 3/8”Vertical 4”1500 .188”4”1475 .188” 8046957 TEK 50 3/8”Vertical 4”1500 .250”4”1475 .188” 8055957 SWDR 1 3/8”Horizontal 4”1500 .037”4”1475 .060” 8056957 SWDR 516 3/8”Horizontal 4”1500 .037”4”1475 .060” 8054957 SWDR 1-1/2 3/8”Horizontal 4”1500 .037”4”1475 .060” 8137957 SH-DSTR 1 3/8”17° Angle off Vertical 4”1500 .035”4”1475 .105” 8268957 SH-TEK 50 3/8”Vertical 2-1/2”850 70° Angle off Vertical 4”1500 8150922 XP 20 3/8”Vertical 2-1/2”850 .027”2”940 .029” 4”1475 .105” 8153922 XP 35 3/8”Vertical 4”1500 .060”2”940 .029” 4”1475 .125” 8294922 SXP 20 3/8”Vertical or up to 45°2”750 .027”2”635 .029” 8295922 SXP 35 3/8”Vertical or up to 89°3-1/2”1250 .060”2”635 .029” 8293957 SWXP 35 3/8”Horizontal 3-1/2”1250 .060” SAMMYS FOR CONCRETE - PIPE HANGER 8059957 CST 20 3/8”Vertical 4”1475 3000 8061957 SWC 20 3/8”Horizontal 4”1475 3000 8150922 XP 20 3/8”Vertical 2-1/2”850 Pre-Pour Structural @ 3000psi 8150922 XP 20 3/8”Vertical 2-1/2”850 Post-Pour Range II LWC ≤ 35 PCF (lbs/ft3) 14 Part Number Model Rod Size Mount Direction UL Load Rating (lbs)UL Min Steel Thickness SAMMYS FOR STEEL - LUMINAIRE FITTING 8150922 XP 20 3/8”Vertical 185 .027” 250 .035” 8153922 XP 35 3/8”Vertical 185 .027” 250 .035” 8181922 XP 200 1/4”Vertical 185 .027” 250 .035” 8294922 SXP 20 3/8”Vertical 170 .027” 45°80 .027” 8295922 SXP 35 3/8”Vertical 250 .060” 90°80 .060” 8293957 SWXP 35 3/8”Horizontal 80 .060” Sheet Steel Gauges Gauge No.22 ga.20 ga.18 ga.16 ga.14 ga.12 ga.1/8”3/16”1/4” Nominal Decimal Equivalent .030”.036”.048”.060”.075”.105”.125”.188”.250” Part Number Model Rod Size Mount Direction UL Load Rating (lbs)UL Min. SteelThickness Listed Application SAMMYS FOR STEEL - CONDUIT, TUBING, AND CABLE 8150922 XP 20 3/8”Vertical 283 .027”Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8”Vertical 500 .060”Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3/8”Vertical 283 .027”Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8”Vertical 500 .060”Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8293957 SWXP 35 3/8”Horizontal 500 .060”Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8149957 CZ2000 1/4” or 3/8”Onto Vertical Rod UL Listed 4S16 - Cable Hanger, Cat. No. C-Z2000 Plenum Rated, Complies w/ NEC Standards *SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2” *SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4” **SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2” **SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3” UL compliance with NEC Standards. UL and FM tests were performed in compliance with NFPA 13 Standards. Fastening requirement: 5 times weight of water-filled schedule 40 pipe plus 250 pounds. APPROVALS For the most up to date information, visit www.itwbuildex.com 15 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETEPart NumberModelRod SizeMount DirectionUL Max Pipe SizeUL Test Load (lbs)UL Min Wood ThicknessFM Max Pipe SizeFM Test Load (lbs)FM Min Wood Thickness SAMMYS FOR WOOD - PIPE HANGER 8007957GST 103/8”VerticalCPVC 1-1/2”3001-1/2” 8020957SWG 103/8”HorizontalCPVC 1-1/2”3001-1/2” 8008957GST 203/8”Vertical2-1/2”8501-1/2”4”14751-1/2” 8068925GST 20-SS3/8”Vertical2-1/2”8501-1/2” 8010957GST 303/8”Vertical4”15001-1/2”4”14751-1/2” 8009925GST 25-3803/8”Vertical4”15001-1/2” 8022925SWG 25-3803/8”Horizontal3-1/2” - 4”*15001-1/2” 8021957SWG 203/8”Horizontal2-1/2” - 3”**10501-1/2” 8073925SWG 20-SS3/8”Horizontal2-1/2”8501-1/2” 8269957SH-GST/CST 203/8”45° Angle off Vertical2-1/2”8501-1/2” 8269957SH-GST/CST 203/8”45° Angle off Vertical4”15001-1/2” 8139957SH-GST 203/8”17° Angle off Vertical3”10501-1/2”4”14751-1/2” SAMMYS FOR STEEL - PIPE HANGERMin Steel ThickMax Steel Thick 8038957DSTR 13/8”Vertical4”1500.035”4”1475.105” 8037957DSTR 1-1/23/8” Vertical4”1500.035”4”1475.105” 8039957DSTR 5163/8”Vertical4”1500.037”4”1475.105” 8045957DST 5163/8”Vertical4”1500.188”4”1475.188” 8046957TEK 503/8”Vertical4”1500.250”4”1475.188” 8055957SWDR 1 3/8”Horizontal4”1500.037”4”1475.060” 8056957SWDR 5163/8”Horizontal4”1500.037”4”1475.060” 8054957SWDR 1-1/23/8”Horizontal4”1500.037”4”1475.060” 8137957SH-DSTR 13/8”17° Angle off Vertical4”1500.035”4”1475.105” 8268957SH-TEK 503/8”Vertical2-1/2”850 70° Angle off Vertical4”1500 8150922XP 203/8”Vertical2-1/2”850.027”2”940.029” 4”1475.105” 8153922XP 353/8”Vertical4”1500.060”2”940.029” 4”1475.125” 8294922SXP 203/8”Vertical or up to 45°2”750.027”2”635.029” 8295922SXP 353/8”Vertical or up to 89°3-1/2”1250.060”2”635.029” 8293957SWXP 353/8”Horizontal3-1/2”1250.060” SAMMYS FOR CONCRETE - PIPE HANGER 8059957CST 203/8”Vertical4”14753000 8061957SWC 203/8”Horizontal4”14753000 8150922XP 203/8”Vertical2-1/2”850Pre-Pour Structural @ 3000psi 8150922XP 203/8”Vertical2-1/2”850Post-Pour Range II LWC ≤ 35 PCF (lbs/ft3) SPECIAL NOTES Engineering Note In 1996, the anchors listed by UL were tested in plate steel that measured .188” and .118”. Subsequent testing was done for z-purlin applications in May 1997 using (.037”) or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Press® was completed using (.030”) or 22 gauge steel metal deck. Sammys® Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric ProductsMetric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for SeismicPlease visit www.itwbuildex.com for our current Seismic product offerring. Vibratory Environments For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8” smaller than root diameter of fastener. Consult the table below: To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPA/NEC StandardsAll UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings / FM ApprovalsUL and FM reports are available at www.itwbuildex.com Technical DrawingsTechnical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Manufactured in the U.S.A. Products Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 Model Root Diameter Hole Size GST 20 .182”1/8” GST 25-380 .280”7/32” SWG 20 .182”1/8” SWG 25-380 .280”7/32” MANUFACTURED U.S.A. Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage Page 1 of 4 FEBRUARY 2014 TFP172 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide Contacts www.tyco-fire.com General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: • A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. • A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2˝ NPT TY323 ......Pendent 5.6K, 1/2˝ NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* * The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi1/2 (80,6 LPM/bar1/2) Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw . . . . . . . . Bronze Deflector .................Bronze TFP172 Page 2 of 4 Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM’s Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Components: 1/2" NPT 1 5 2 3 4 2" (50,8 mm) Frame Button Sealing Assembly *6 2 - -3 -1 *-6 Deector Compression Screw -5 4 -Bulb 2-7/8" (73,0 mm) DIA. 1-3/8" (34,9 mm) 2" (50,8 mm) WRENCH FLATS 7/16" (11,1 mm) NOMINAL MAKE-IN STYLE 15 or 20 RECESSED ESCUTCHEON 7/16" (11,1 mm) NOMINAL MAKE-IN Pipe thread connections per ISO 7-1 can be provided on special request. **DEFLECTOR * Temperature rating is indicated on Deector. DEFLECTOR * * ESCUTCHEON PLATE SEATING SURFACE ** **1/2" NPT UPRIGHTCROSS SECTION PENDENT RECESSED PENDENT WRENCH RECESS (USE ONLY END "A") WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE FIGURE 2 W-TYPE 6 SPRINKLER WRENCH FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFP172 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. MOUNTING PLATE MOUNTING SURFACE CLOSURE SERIES TY-FRB 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER FITTING 2-1/4" DIA. (57,2 mm) 1/8" (3,2 mm) 3/8±5/16" (9,5±7,9 mm) 1-3/8" (34,9 mm) 5/8" (15,9 mm) 3/4" (19,1 mm) FLUSH MOUNTING SURFACE SERIES TY-FRB CLOSURE MOUNTING PLATE 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) FACE OF SPRINKLER FITTING 1/8" (3,2 mm) 5/16±1/4" (7,9±6,4 mm)1/2" (12,7 mm) 1-3/8" (34,9 mm) FLUSH 7/8" (22,2 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP172 Page 4 of 4 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 SIN 370 5.6K UPRIGHT (1/2˝ NPT)TY313 371 5.6K PENDENT (1/2˝ NPT)TY323 SPRINKLER FINISH 1 NATURAL BRASS 3 PURE WHITE (RAL9010)** POLYESTER 4 SIGNAL WHITE (RAL9003) POLYESTER 9 CHROME PLATED TEMPERATURE RATINGS 135 135°F (57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C)** Eastern Hemisphere sales only * Use suffix “I” for ISO 7-1 connection; for example, 77-370-4-175-I TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION P/N* 77 – XXX – X – XXX OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org March 10, 2021 TCB Industries LLC. 11301 Sunset Ave Banning, CA 92220 Re: TI Fire Sprinkler Plan Review – LQ VILLAGE SHOPPING FSS2021-0042 / 50929 WASHINGTON STREET, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. The following inspections/tests are required to be witnessed by the Office of the Fire Marshal staff: 1) Overhead Rough: All installed/relocated piping must be visible. 2) Final inspection: All trim is in place, 5-Year certification is current. New/added heads shall be included in the spare head box compliment. *Water-flow signal test may be performed during the Final Inspection. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 50929 WASHINGTON STREET PERMIT#: FSS2021-0042 DATE ISSUED: 3/10/2021 DESCRIPTION: LQ VILLAGE SHOPPING (SHELL RESTORE) CONTRACTOR: TCB INDUSTRIES HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.