FSS2021-0045ADDITIONAL SITES
CHRONOLOGY
CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES
NOTE JULIA AGGREH 1/20/2022 1/20/2022
CONTRACTOR REQUESTED FINAL INSPECTION. PERMIT
EXPIRED AS OF 3/18/21 (6 MOS FROM DATE OF LAST
APPROVED INSPECTION). ADDED EXTENSION FEE OF $83 AND
EXTENDED PERMIT TO 1/21/22 SO CONTRACTOR CAN PAY
FEE VIA ETRAKIT. WILL ALSO REQUIRE AN EXTENSION
REQUEST LETTER FROM CONTRACTOR. OK TO EXTEND PER
KOHL.
CONTRACTOR SUBMITTED EXTENSION LETTER AND PAID FEE.
EXTENDED PERMIT FOR ANOTHER 6 MOS FROM EXTENSION
FEE PAYMENT.
NOTE KAYLI ALFORD 3/18/2021 3/18/2021
ON HOLD UNTIL BUILDING PERMIT IS ISSUED. CANNOT HAVE
FIRE SPRINKLER PERMIT WITHOUT BUILDING PERMIT ISSUED.
CONTRACTOR WAS NOTIFIED VIA EMAIL.
Description: adding 4 sprinkler heads to a existing home / BRES2020-0334
Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM
HOMES
Status: FINALED Applied: 3/4/2021 ECON
Parcel No: 762500016 Site Address: 57872 BARRISTO CIR LA QUINTA,CA 92253 Approved: 3/18/2021 KHET
Subdivision: TR 32225 Block: Lot: 16 Issued: 3/18/2021 ONLINE
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 1/27/2022 KHET
Valuation: $1,000.00 Occupancy Type: Construction Type: Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details:
Printed: Monday, February 27, 2023 3:27:00 PM 1 of 4
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2021-0045
CONTACTS
NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL
APPLICANT J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 (760)625-5908 JCFIREPROTECTION@V
ERIZON.NET
CONTRACTOR J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 (760)625-5908 JCFIREPROTECTION@V
ERIZON.NET
OWNER ken von Kriegenbergh 57872 barristo circle la quinta CA 92253 (760)625-5908 kbvk1962@gmial.com
NOTE KAYLI ALFORD 5/11/2021 5/11/2021
BUILDING PERMIT ISSUED AS OF 5/7/21. CHANGED STATUS
OF THIS PERMIT FROM "ON HOLD" TO "ISSUED" AS OF
5/11/21
CONDITIONS
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
FIRE SPRINKLER
SYSTEMS - SINGLE
FAMILY DETACHED
101-0000-42421 0 $161.00 $161.00 3/18/21 WEB7687 003126 CREDIT J C FIRE PROTECTION ECON
FIRE SPRINKLER
SYSTEMS - SINGLE
FAMILY DETACHED PC
101-0000-42420 0 $242.00 $242.00 3/18/21 WEB7687 003126 CREDIT J C FIRE PROTECTION ECON
FIRE STAFF - PER HOUR 101-0000-42420 1 $83.00 $83.00 1/20/22 WEB10429 634912794
54 CREDIT 996335 ECON
Total Paid for FIRE FEES: $486.00 $486.00
RECORDS
MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 3/18/21 WEB7687 003126 CREDIT J C FIRE PROTECTION ECON
Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00
TECHNOLOGY
ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 3/18/21 WEB7687 003126 CREDIT J C FIRE PROTECTION ECON
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
TOTALS:$501.00 $501.00
Printed: Monday, February 27, 2023 3:27:00 PM 2 of 4
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2021-0045
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 3/4/2021 EtrakitContractor 1ST SUBMITTAL PLAN scan0019 copy.pdf 1
DOC 3/4/2021 EtrakitContractor 1ST SUBMITTAL RFC
SPRINKLERS
Model_RFC_Residential
_Concealed_Sprinkler.p
df
1
DOC 3/4/2021 EtrakitContractor 1ST SUBMITTAL
APPICATION
FIRE APPLICATION
SEPTEMBER 2019 FEE
UPDATE REVISED 3 .pdf
1
DOC 3/4/2021 EtrakitContractor 1ST SUBMITTAL STAND
OFF HANGER fig28 copy.pdf 1
DOC 3/4/2021 EtrakitContractor 1ST SUBMITTAL PIPE
CLAMPS
pc-cpvc-double-offset
copy.pdf 1
BOND INFORMATION
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED
DATE
COMPLETED
DATE
RESULT REMARKS NOTES
OVERHEAD ROUGH
PIPING
KHET 5/12/2021 5/12/2021 APPROVED
OVERHEAD HYRO KHET 5/12/2021 5/12/2021 APPROVED
FIRE FINAL**KHET 1/27/2022 1/27/2022 APPROVED
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED
DATE
STATUS REMARKS NOTES
1ST FIRE (2 WK)KOHL
HETRICK
3/4/2021 3/18/2021 3/18/2021 APPROVED SEE ATTACHMENTS
1ST PERMIT TECH (1
DAY)
AARON
HICKSON
3/4/2021 3/5/2021 3/4/2021 COMPLETE
PARENT PROJECTS
Printed: Monday, February 27, 2023 3:27:00 PM 3 of 4
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2021-0045
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 3/4/2021 EtrakitContractor 1ST SUBMITTAL CPVC blazemaster.pdf 1
DOC 1/20/2022 JULIA AGGREH
Request for Extension
Letter FSS2021-
0045.pdf
Request for Extension
Letter FSS2021-
0045.pdf
0
DOC 3/18/2021 KOHL HETRICK FSS2021-0045 -
APPROVED PLANS.pdf
FSS2021-0045 -
APPROVED PLANS.pdf 1
DOC 3/18/2021 KOHL HETRICK FSS2021-0045 - COA
AND JOB CARD.pdf
FSS2021-0045 - COA
AND JOB CARD.pdf 1
Printed: Monday, February 27, 2023 3:27:00 PM 4 of 4
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2021-0045
FSS2021-0045
Model RFC & G5 Cover Plate
Model RFC43 & RFC43LLModel RFC30 & RFC30LL
Model RFC49 & RFC49LL Model RFC58
Features
• cULus Listed as Residential Sprinklers
• Push-On cover plate installation
• Low water flow requirements
Product Description
Model RFC Series residential sprinklers are flat cover plate,
concealed pendent sprinklers intended for installation in
accordance with NFPA 13, NFPA 13R, or NFPA 13D. The
sprinklers are cULus Listed as Residential Sprinklers in ac-
cordance with UL 1626. In addition, Model RFCLL Series
sprinklers are cULus Certified for Health Effects to NSF/ANSI
standard 61 Annex G (LL) and Australian WaterMark Certified
(WMCS).
Model RFC30 sprinklers have a 165°F (74°C) temperature
rated fusible-link operating element. Model RFC43, RFC49,
RFC58, and RFC76 sprinklers are offered with either a 165°F
(74°C) or 212°F (100°C) temperature rated fusible-link oper-
ating element. Sprinklers with a 165°F (74°C) temperature
rating are ordinary temperature classification and are listed
for use with a 135°F (57°C) temperature rated cover plate.
Sprinklers with a 212°F (100°C) temperature rating are inter-
mediate temperature classification and are listed for use with
a 165°F (74°C) temperature rated cover plate.
Model RFC Series sprinklers are installed with a Model RFC
or Model G5 Cover Plate. Model G5 Cover Plates may be
installed by either pushing or threading the cover plate into
the sprinkler cup. Model RFC30, RFC30LL, RFC43, RFC43LL,
RFC49 and RFC49LL sprinklers allow 1/2” (13 mm) of cover
plate adjustment. Model RFC58 and RFC76 sprinklers allow
3/4” (19 mm) of cover plate adjustment. Model RFC and G5
Cover Plates are available in a variety of finishes as listed in
Table H.
www.reliablesprinkler.com
Sprinkler Model Nominal K-Factor
gpm/psi1/2 (l/min/bar1/2)
Max. Coverage Area
ft x ft (m x m)
Listings &
Approvals
Sprinkler Identification
Number (SIN)
RFC30 3.0 (43)14 x 14 (4.3 x 4.3)cULus RA0611
RFC30LL 3.0 (43)14 x 14 (4.3 x 4.3)cULus, LL, WMCS RA3211
RFC43 4.3 (62)20 x 20 (6.1 x 6.1)cULus RA0612
RFC43LL 4.3 (62)20 x 20 (6.1 x 6.1)cULus, LL, WMCS RA3212
RFC49 4.9 (71)20 x 20 (6.1 x 6.1)cULus RA0616
RFC49LL 4.9 (71)20 x 20 (6.1 x 6.1)cULus, LL, WMCS RA3216
RFC58 5.8 (84)20 x 20 (6.1 x 6.1)cULus RA0613
RFC76 7.6 (109)20 x 20 (6.1 x 6.1)cULus RA0618
Table A
cULus: cULus Listed to UL1626, Residential Sprinklers for Fire Protection Service.
LL: cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content).
WMCS: Australian WaterMark Certified.
Model RFC76
cULus Listed
Model RFC Series Residential Sprinklers
Flat Concealed Pendent
Bulletin 006 September 2020
Bulletin 006
September 2020
Page 2 of 8
www.reliablesprinkler.com
Model RFC30 & RFC30LL Sprinkler Components and Dimensions Figure 1
Model RFC30 and RFC30LL Sprinkler Hydraulic Design Criteria Table B
Minimum Flow and Residual Pressure (1)
Max. Coverage Area (2)
ft. x ft.
(m x m)
Flow
gpm
(l/min)
Pressure
psi
(bar)
12 x 12
(3.6 x 3.6)
9
(34)
9.0
(0.62)
14 x 14
(4.3 x 4.3)
10
(38)
11.0
(0.76)
Notes:
1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table B above and (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
Technical Specifications
Style: Flat Concealed Pendent
Threads: 1/2” NPT or ISO 7-1R1/2
Nominal K-Factor: 3.0 (43 metric)
Max. Working Pressure: 175 psi (12 bar)
Min. Spacing: 8 ft. (2.4 m)
Material Specifications
Thermal Sensor: Nickel Alloy Solder Link
Sprinkler Body: Brass Alloy
Levers: Bronze Alloy
Yoke: Brass Alloy
Sealing Assembly: Nickel Alloy with PTFE
Load Screw: Bronze Alloy
Towers: Copper Alloy
Pins: Stainless Steel
Deflector: Bronze Alloy
Cup: Steel
Cover Plate Finishes
(See Table H)
Sensitivity
Fast-response
Temperature Rating
165°F (74°C) sprinkler
135°F (57°C) cover plate
Cover Plate
Model RFC Cover Plate
Model G5 Cover Plate
Sprinkler Wrench
Model FC (without wrench-able cap)
Model W3 (with wrench-able cap)
Listings and Approvals
cULus Listed to UL 1626
cULus Certified for Health Effects to NSF/ANSI
Standard 61 Annex G (RFC30LL only)
Watermark Certified (RFC30LL only)
Bottom View
Model RFC30 & RFC30LL Residential Sprinklers RFC30: SINRA0611
RFC30LL: SINRA3211
Bulletin 006
September 2020
Page 3 of 8
www.reliablesprinkler.com
Model RFC43 & RFC43LL Sprinkler Hydraulic Design Criteria Table C
Minimum Flow and Residual Pressure (1)
Max. Coverage Area (2)
ft. x ft.
(m x m)
Ordinary Temperature Intermediate Temperature
Flow
gpm
(l/min)
Pressure
psi
(bar)
Flow
gpm
(l/min)
Pressure
psi
(bar)
15 x 15
(4.6 x 4.6)
12
(45)
7.8
(0.54)
12
(45)
7.8
(0.54)
16 x 16
(4.9 x 4.9)
13
(49)
9.1
(0.63)
13
(49)
9.1
(0.63)
18 x 18
(5.5 x 5.5)
18
(68)
17.5
(1.21)----
20 x 20
(6.1 x 6.1)
21
(79)
23.8
(1.64)----
Notes:
1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table C above and (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
Model RFC43 & RFC43LL Sprinkler Components and Dimensions Figure 2
Technical Specifications
Style: Flat Concealed Pendent
Threads: 1/2” NPT or ISO 7-1R1/2
Nominal K-Factor: 4.3 (62 metric)
Max. Working Pressure: 175 psi (12 bar)
Min. Spacing: 8 ft. (2.4 m)
Material Specifications
Thermal Sensor: Nickel Alloy Solder Link
Sprinkler Body: Brass Alloy
Levers: Bronze Alloy
Yoke: Brass Alloy
Sealing Assembly: Nickel Alloy with PTFE
Load Screw: Bronze Alloy
Towers: Copper Alloy
Pins: Stainless Steel
Deflector: Bronze Alloy
Cup: Steel
Cover Plate Finishes
(See Table H)
Sensitivity
Fast-response
Temperature Rating
Ordinary:
165°F (74°C) sprinkler
135°F (57°C) cover plate
Intermediate:
212°F (100°C) sprinkler
165°F (74°C) cover plate
Cover Plate
Model RFC Cover Plate
Model G5 Cover Plate
Sprinkler Wrench
Model FC (without wrench-able cap)
Model W3 (with wrench-able cap)
Listings and Approvals
cULus Listed to UL 1626
cULus Certified for Health Effects to NSF/ANSI
Standard 61 Annex G (RFC43LL only)
Watermark Certified (RFC43LL only)
Bottom View
Model RFC43 & RFC43LL Residential Sprinklers RFC43: SINRA0612
RFC43LL: SINRA3212
Technical Specifications
Style: Flat Concealed Pendent
Threads: 1/2” NPT or ISO 7-1R1/2
Nominal K-Factor: 4.9 (71 metric)
Max. Working Pressure: 175 psi (12 bar)
Min. Spacing: 8 ft. (2.4 m)
Material Specifications
Thermal Sensor: Nickel Alloy Solder Link
Sprinkler Body: Brass Alloy
Levers: Bronze Alloy
Yoke: Brass Alloy
Sealing Assembly: Nickel Alloy with PTFE
Load Screw: Bronze Alloy
Towers: Copper Alloy
Pins: Stainless Steel
Deflector: Bronze Alloy
Cup: Steel
Cover Plate Finishes
(See Table H)
Sensitivity
Fast-response
Temperature Rating
Ordinary:
165°F (74°C) sprinkler
135°F (57°C) cover plate
Intermediate:
212°F (100°C) sprinkler
165°F (74°C) cover plate
Cover Plate
Model G5 Cover Plate
Sprinkler Wrench
Model FC (without wrench-able cap)
Model W3 (with wrench-able cap)
Listings and Approvals
cULus Listed to UL 1626
cULus Certified for Health Effects to NSF/ANSI
Standard 61 Annex G (RFC49LL only)
Watermark Certified (RFC49LL only)
Model RFC49 & RFC49LL Sprinkler Components and Dimensions Figure 3
Model RFC49 & RFC49LL Sprinkler Hydraulic Design Criteria Table D
Minimum Flow and Residual Pressure (1)
Max. Coverage Area (2)
ft. x ft.
(m x m)
Ordinary Temperature Intermediate Temperature
Flow
gpm
(l/min)
Pressure
psi
(bar)
Flow
gpm
(l/min)
Pressure
psi
(bar)
16 x 16
(4.9 x 4.9)
13
(49.0)
7.0
(0.48)
13
(49.0)
7.0
(0.48)
18 x 18
(5.5 x 5.5)
17
(64.3)
12.0
(0.83)
17
(64.3)
12.0
(0.83)
20 x 20
(6.1 x 6.1)
20
(75.7)
16.7
(1.15)
21
(79.5)
18.4
(1.27)
Notes:
1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table D above and (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
Bulletin 006
September 2020
Page 4 of 8
www.reliablesprinkler.com
Bottom View
Model RFC49 & RFC49LL Residential Sprinklers RFC49: SINRA0616
RFC49LL: SINRA3216
Model RFC58 Residential Sprinkler SIN RA0613
Technical Specifications
Style: Flat Concealed Pendent
Threads: 1/2” NPT or ISO 7-1R1/2
Nominal K-Factor: 5.8 (84 metric)
Max. Working Pressure: 175 psi (12 bar)
Min. Spacing: 8 ft. (2.4 m)
Material Specifications
Thermal Sensor: Nickel Alloy Solder Link
Sprinkler Body: Brass Alloy
Levers: Bronze Alloy
Yoke: Brass Alloy
Sealing Assembly: Nickel Alloy with PTFE
Load Screw: Bronze Alloy
Towers: Copper Alloy
Pins: Stainless Steel
Deflector: Chrome Plated Bronze Alloy
Cup: Steel
Cover Plate Finishes
(See Table H)
Sensitivity
Fast-response
Temperature Ratings
Ordinary:
165°F (74°C) sprinkler
135°F (57°C) cover plate
Intermediate:
212°F (100°C) sprinkler
165°F (74°C) cover plate
Cover Plate
Model G5 Cover Plate
Sprinkler Wrench
Model FC (without wrench-able cap)
Model W3 (with wrench-able cap)
Listings and Approvals
cULus Listed
Model RFC58 Sprinkler Components and Dimensions Figure 4
Model RFC58 Sprinkler Hydraulic Design Criteria Table E
Minimum Flow and Residual Pressure( 1)
Max. Coverage Area (2)
ft. x ft.
(m x m)
Flow
gpm
(l/min)
Pressure
psi
(bar)
16 x 16
(4.9 x 4.9)
16
(60.6)
7.6
(0.53)
18 x 18
(5.5 x 5.5)
18
(68.1)
9.6
(0.66)
20 x 20
(6.1 x 6.1)
20
(75.7)
11.9
(0.82)
Bulletin 006
September 2020
Page 5 of 8
www.reliablesprinkler.com
Notes:
1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
Bottom View
Bulletin 006
September 2020
Page 6 of 8
www.reliablesprinkler.com
Technical Specifications
Style: Flat Concealed Pendent
Threads: 3/4” NPT or ISO 7-1R3/4
Nominal K-Factor: 7.6 (109 metric)
Max. Working Pressure: 175 psi (12 bar)
Min. Spacing: 8 ft. (2.4 m)
Material Specifications
Thermal Sensor: Nickel Alloy Solder Link
Sprinkler Body: Brass Alloy
Levers: Bronze Alloy
Yoke: Brass Alloy
Sealing Assembly: Nickel Alloy with PTFE
Load Screw: Bronze Alloy
Towers: Copper Alloy
Pins: Stainless Steel
Deflector: Bronze Alloy
Cup: Steel
Cover Plate Finishes
(See Table H)
Sensitivity
Fast-response
Temperature Ratings
Ordinary:
165°F (74°C) sprinkler
135°F (57°C) cover plate
Intermediate:
212°F (100°C) sprinkler
165°F (74°C) cover plate
Cover Plate
Model G5 Cover Plate
Sprinkler Wrench
Model FC (without wrench-able cap)
Model W3 (with wrench-able cap)
Listings and Approvals
cULus Listed
Model RFC76 Flat Concealed Sprinkler Hydraulic Design Criteria Table E
Minimum Flow and Residual Pressure( 1)
Max. Coverage Area (2)
ft. x ft.
(m x m)
Flow
gpm
(l/min)
Pressure
psi
(bar)
16 x 16
(4.9 x 4.9)
21
(79.5)
7.6
(0.52)
18 x 18
(5.5 x 5.5)
24
(90.8)
9.9
(0.68)
20 x 20
(6.1 x 6.1)
34
(128.7)
20
(1.4)
Notes:
1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
Bottom View
Model RFC76 Residential Sprinkler SIN RA0618
Model RFC76 Sprinkler Components and Dimensions Figure 5
Standard Finishes Special Application Finishes
White Polyester Off White Paint Black Paint Raw Brass
Chrome Plated Bright Brass Finished Bronze Black Plated
Satin Chrome Stainless Steel Clad(3)Custom Color Paint(2)
Notes:
1. Paint or any other coating applied over the factory finish will void all approvals and warranties.
2. Custom color paint is semi-gloss, unless specified otherwise.
3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the back side. Cover plates
are not listed or approved as corrosion resistant.
Cover Plate Finishes(1) Table H
Bulletin 006
September 2020
Page 7 of 8
www.reliablesprinkler.com
Notes:
1. Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method
prior to installation. A 1/2” x 1/2” brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing
sprinklers.
2. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (38°C).
3. For use with 212°F (100°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F (66°C).
Sprinkler
Model
Cover
Plate
Model
Cover Plate
Diameter
inch (mm)
Recommended
Hole Diameter
in Ceiling
inch (mm)
Cover Plate
Adjustment
inch (mm)
Min. to
Max. Face
of Fitting to
Ceiling(1)
inch (mm)
Min. to Max.
Dropped Deflector
Distance below
Ceiling
inch (mm)
Cover Plate
Temperature
Rating
RFC30,
RFC30LL
RFC or
G5
3-5/16
(84)
2-5/8
(67)
1/2
(13)
1-1/2 to 2
(38 to 51)
1/2 to 1
(13 to 25)
135°F
(57°C)
RFC43,
RFC43LL,
RFC49,
RFC49LL
RFC or
G5
3-5/16
(84)
2-5/8
(67)
1/2
(13)
1-1/2 to 2
(38 to 51)
1/2 to 1
(13 to 25)
135°F(2)
(57°C)
or 165°F(3)
(74°C)
RFC58,
RFC76
RFC or
G5
3-5/16
(84)
2-5/8
(67)
3/4
(19)
1-1/2 to 2-1/4
(38 to 57)
1/4 to 1
(6 to 25)
135°F(2)
(57°C)
or 165°F(3)
(74°C)
Table JInstallation Dimensions
Installation
Model RFC series sprinklers are intended to be installed in
accordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as
the requirements of applicable authorities having jurisdiction.
Model RFC series sprinklers must not be installed in ceilings with
positive pressure in the space above. Ensure that the 4 slots in
the cup are open and unobstructed following installation. Model
RFC series sprinklers are shipped with a wrench-able protective
cap that should remain on the sprinkler until the sprinkler system
is placed in service following construction.
Model RFC series sprinklers can be installed without removing
the wrench-able protective cap using the Model W3 wrench.
Alternatively, Model RFC series sprinklers can be installed using
the Model FC wrench by temporarily removing the protective cap
during installation of the sprinkler. The use of any other wrench to
installed Model RFC series sprinklers is not permitted and may
damage the sprinkler. Fully insert the Model W3 wrench over
the cap until it reaches the bottom of the cup, or the Model FC
wrench over the sprinkler until the wrench engages the body.
Do not wrench any other part of the sprinkler/cup assembly. The
Model W3 and FC wrenches are designed to be turned with a
standard 1/2” square drive. Tighten the sprinkler into the fitting
after applying a PTFE based thread sealant to the sprinkler’s
threads. Recommended installation torque is 8 to 18 ft-lbs (11
to 24 N-m) for 1/2” thread sprinklers and 14 to 20 ft-lbs (19 to 27
N-m) for 3/4” thread sprinklers.
Do not exceed the maximum recommended torque. Exceeding
the maximum recommended torque may cause leakage or
impairment of the sprinkler. Use care when inserting or removing
the wrench from the sprinkler to avoid damage to the sprinkler.
Install the cover plate by hand by pushing the cover plate into the
cup and turning the cover in the clockwise direction until it is tight
against the ceiling.
Application
Model RFC series sprinklers are intended for installation where
residential sprinklers are permitted or required by NFPA 13,
NFPA 13R, and NFPA 13D. The sprinklers are concealed
pendent residential sprinklers.
Model RFC 30 and RFC30LL sprinklers are available in
ordinary temperature classification for installation where
the Maximum Ceiling Temperature does not exceed 100°F
(38°C). Model RFC43, RFC43LL, RFC49, RFC49LL, RFC58,
and RFC76 sprinklers are available in either ordinary or
intermediate temperature classification for installation where
the Maximum Ceiling Temperature does not exceed 100°F
(38°C) or 150°F (66°C), respectively.
Listings and Approvals
Listed by Underwriters Laboratories, Inc. and UL Certified for
Canada to UL1626, Residential Sprinklers for Fire-protection
Service (cULus).
Certified by Underwriters Laboratories, Inc. and Underwrit-
ers Laboratories of Canada for Health Effects to NSF/ANSI
Standard 61 Annex G (LL) (RFC30LL, RFC43LL, and RFC49LL
only).
Australian WaterMark Certified (RFC30LL, RFC43LL, and
RFC49LL only).
Patents
Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL,
RFC58, and RFC76 sprinklers are covered by U.S. Patent No.
9,248,327 and U.S. Patent No. 7,275,603.
Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are
additionally covered by U.S. Patent No. 8,776,903.
Ordering Information
Specify the following when ordering.
Sprinkler
• Model (RFC30, RFC30LL, RFC43, RFC43LL,
RFC49, RFC49LL, RFC58, RFC76)
• Temperature Rating
Cover Plate
• Model RFC or G5
• Temperature Rating
• Finish (See Table H)
Sprinkler Wrench
• Model FC
• Model W3
• Model W8 (Limited use)
Maintenance
Model RFC series sprinklers should be inspected and the
sprinkler system maintained in accordance with NFPA 25. Do
not clean sprinklers with soap and water, ammonia or any other
cleaning fluids. Remove dust by gentle vacuuming. Replace
any sprinkler cover plate assembly which has been painted
(other than factory applied) or damaged in any way. A stock of
spare sprinklers should be maintained to allow quick replace-
ment of damaged or operated sprinklers. Prior to installation,
sprinklers should be maintained in the original cartons and
packaging until used to minimize the potential for damage to
sprinklers that would cause improper operation or non-oper-
ation.
Guarantee
For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms,
and conditions, visit www.reliablesprinkler.com.
Bulletin 006
September 2020
Page 8 of 8
www.reliablesprinkler.com P/N 9999970261Model FC
For use with Model RFC Series sprinklers
without wrench-able cap installed
Installation Wrenches
Model W3
For use with Model RFC Series sprinklers
with wrench-able cap installed
Model W8
High-strength plastic wrench
for limited (emergency)
use with Model RFC
Series sprinklers without
wrench-able cap installed.
Meets NFPA requirements
for sprinkler wrench on
premises.
Service/Spare Head Cabinet Wrench
General
Description
Tyco Fire & Building Products (TFBP)
BlazeMaster CPVC Pipe and Fittings
are designed exclusively for use in wet
pipe automatic fire sprinkler systems.
They are made from a specially devel-
oped thermoplastic compound com-
posed of post chlorinated polyvinyl
chloride (CPVC) resin and state of the
art additives. TFBP BlazeMaster
CPVC products are easier to install
than traditional steel pipe systems,
and at the same time, provide superior
heat resistance and strength as com-
pared to traditional CPVC and PVC
piping materials used in the plumbing
trade. Various adapters are available
to connect CPVC pipe to metallic pip-
ing. All female pipe thread adapters
have brass inserts for durability.
Grooved adapters connect directly to
grooved end valves and metallic pipe,
with flexible grooved end couplings.
WARNING
Tyco Fire & Building Products (TFBP)
BlazeMaster CPVC Pipe and Fittings
described herein mustbe installed and
maintained in compliance with this
document, as well as with the applica-
ble standards of the National Fire Pro-
tection Association, in addition to the
standards of any other authorities hav-
ing jurisdiction.Failure to do so may
impair the performance of these de-
vices.
The owner is responsible for maintain-
ing their fire protection system and de-
vices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted
with any questions.
Technical
Data
Sizes
3/4" to 3"
Maximum Working Pressure
175 psi
Approvals
UL, FM, CUL, NSF, Dade County,
LPCB, MEA, and the City of Los Ange-
les. (Refer to IH-1900, Rev. 0, Janu-
ary 2005 “Installation Instruction &
Technical Handbook” for exact list-
ing/approval information.)
Manufacture Source
U.S.A.
Material
•Pipe: ASTM F442, SDR 13.5
•Fittings: ASTM F438 (Sch. 40) and
ASTM F439 (Sch. 80), ASTM F1970
Color
Orange
BlazeMaster ®
CPVC Fire Sprinkler Pipe & Fittings
Submittal Sheet
Page 1 of 6 TFP1915JANUARY, 2006
Technical Services:Tel: (800) 381-9312 / Fax: (800) 791-5500
BlazeMaster®is a registered trademark
of Noveon IP Holding Corp.
Installation
Tyco Fire and Building Products
(TFBP) BlazeMaster CPVC Pipe and
Fittings are to be installed in accord-
ance with IH-1900, Rev. 0, January
2005“Installation Instruction &Techni-
cal Handbook”.
Care and
Maintenance
The owner is responsible for the in-
spection, testing, and maintenance of
their fire protection system and de-
vices in compliance with this docu-
ment, as well as with the applicable
standards of the National Fire Protec-
tion Association (e.g., NFPA 25), in
addition to the standards of any
authority having jurisdiction. The in-
stallingcontractor orproductmanufac-
turer should be contacted relative to
any questions.
It is recommended that automatic
sprinkler systems be inspected,
tested, and maintained by a qualified
Inspection Service in accordance with
local requirements and/or national
codes.
NOTES
Before closing a fire protection system
control valve for inspection or mainte-
nance work on the fire protection sys-
tem that it controls, permission to shut
down the affected fire protection sys-
tem must first be obtained from the
proper authorities and all personnel
who may be affected by this action
must be notified.
After placing a fire protection system
in service, notify the proper authorities
and advise thoseresponsibleformoni-
toring proprietary and/or central sta-
tion alarms.
Page2of6 TFP1915
FIGURE 1 — PIPE DIMENSIONS
2"
1"
1-1/4"
1-1/2"
3/4"
2.375" 2.003"
1.315"
1.660"
1.900"
1.050"
1.101'
1.394"
1.598"
0.874"
SIZE
NOMINAL
2.200.84
0.67
0.44
1.08
1.41
0.26
0.42
0.54
0.18
3"
2-1/2"
3.500" 2.952"
2.875" 2.423"
4.831.87
3.261.26
10841260
1320
1339
1191
1213
5040
2835
2205
7875
1344720
15311215
O.D.
AVERAGE
lbs./ft.
WEIGHTAVERAGE
I.D.FILLED WEIGHT
WATER
lbs./ft.
FT. OF PIPE
PER LIFT
WEIGHT PER LIFT
lbs.
TFP1915 Page3of6
FIGURE 2 — FITTING DIMENSIONS (Part 1 of 4)
NOMINAL TAKE-OUTFITTINGNOMINAL SIZETYPE
PART
NUMBER (T/O)
T/O T/O
80004
80003
80002
TEE
T/O 80001
80000
2"
1-1/4"
1-1/2"
3/4"
1"
1-3/8"
1-1/16"
7/8"
0.90
0.51
0.26
5/8"
11/16"0.19
0.11
REDUCING TEE
1-1/2" x 1-1/2" x 1-1/4"
80266
80267
80274
80264
80275
80261
80262
80263
80260
2" x 2" x 3/4"
2" x 2" x 1"
2" x 2" x 1-1/2"
1-1/2" x 1-1/2" x 1"
7/8"
1-1/8"
1-1/16"
7/8"
9/16"
1-1/2" x 1-1/2" x 3/4"
1-1/4" x 1-1/4" x 3/4"
1-1/4" x 1-1/4" x 1"
1" x 1" x 3/4"
5/8"
9/16"
3/4"
5/8"
1-3/8"
1-3/8"
1-3/8"
7/8"
9/16"
1"
1-1/16"
0.66
0.78
0.74
0.45
0.38
7/8"5/8"
9/16"
3/4"
1"
7/8"
5/8" 13/16"
0.23
0.36
0.26
0.16
YXx YxZ XZ
80132 3/4" x 3/4" x 1" 3/4" 3/4" 5/8"
0.14
80133 9/16"1" x 3/4" x 3/4" 9/16"
0.143/4"
80134 1" x 3/4" x 1" 3/4" 11/16" 3/4"
0.17
80135 1-1/4" x 1" x 3/4" 5/8"5/8"0.2115/16"
80136 1-1/4" x 1" x 1" 3/4" 3/4" 15/16"
0.22
15/16"1-1/4" x 1" x 1-1/4"80137 15/16"
0.267/8"
80138 1-1/4" x 1-1/4" x 1-1/2"
1" 1" 1" 0.43
80140 1-1/2" x 1-1/4" x 3/4" 9/16" 9/16"
1" 0.36
1-1/2" x 1-1/4" x 1"80141 9/16" 9/16"
0.381-1/16"
80265 3/4" 1-3/8"
0.61
T/O
T/O T/O
X Y
Z
7/8"
1-1/8"
1-1/16"
3/4"
WEIGHT
(lb.)
T/O
T/O
T/O T/O
CROSS & REDUCING CROSS
1-1/16"
80009
80010
80011
80013
80012
0.139/16"
1-5/16"
11/16"
15/16"
1.00
0.23
0.34
0.67
80006
80005
3"
2-1/2"
1-13/16"
1-9/16"
2.41
1.59
2-1/2" x 2-1/2" x 1-1/2"
80270
80269
80268
80272
80273
80271
3" x 3" x 1-1/2"
3" x 3" x 2"
3" x 3" x 2-1/2"
2-1/2" x 2-1/2" x 1-1/4"
1-13/16"
1-13/16"
1-13/16"
1-9/16"
1-9/16"
2-1/2" x 2-1/2" x 1" 1-9/16"
1-13/16"
1-13/16"
1-3/4"
1-9/16"
1-9/16"
1-9/16"
1-9/16"
2.28
2.44
2.25
1.48
1.46
1-9/16" 1-9/16"
1.43
80276 2-1/2" x 2-1/2" x 2" 1-9/16" 1-9/16"
1.50
1-13/16"
1-13/16"
1-13/16"
1-9/16"
2" x 2" x 1-1/4"
1-9/16"
80008
80014
1-13/16" 2.89
1.91
2"
1-1/4"
1-1/2"
3/4"
1"
3"
2-1/2"
80015 0.281" x 1" x 3/4" x 3/4" 7/8"
SCHD.
80
40
80
40
40
80
80
80
80
80
80
40
40
40
40
40
40
40
40
40
80
80
80
80
80
80
80
80
80
80
80
80
80
80
40
80
40
40
80
80
40
T/O
T/O
90° ELBOW &
1-1/16"
80029
80026
80025
80027
80028
2"
3/4"
1"
1-1/4"
1-1/2"
0.791-5/16"
5/8"
3/4"
7/8"0.21
0.14
0.40
0.09
Y
X
1-9/16"
80031
80030
3"
2-1/2"
1.821-13/16"
1.14
XxY
80032 1" x 3/4"
0.16
X
11/16"
Y
13/16"
REDUCING ELBOW
80
40
80
40
40
80
80
40
Page4of6 TFP1915
FIGURE 2 — FITTING DIMENSIONS (Part 2 of 4)
0.2580078
T/O
80079 0.38
T/O
COUPLING &
T/O
45° ELBOW
80053
80054
80075
80076
80077
80050
80051
80052
0.311/2"
1/8"
3/4"
0.11
0.07
0.12
0.56
3/8"
3/8"
3/4"
0.08
0.11
0.20
1/8"
3/16"
3/16"
3/16"
80203
80206
80205
80204
80200
80201
80202
80207
80208
80209
T/O
REDUCER BUSHING
2" x 1-1/4"
2" x 1-1/2"
2" x 1"
1-1/2" x 3/4"
1-1/2" x 1-1/4"
1-1/4" x 3/4"
1-1/2" x 1"
2" x 3/4"
1-1/4" x 1"
1" x 3/4"
11/16"
9/16"
7/16"
5/8"
1/2"
13/16"
3/8"
5/16"
1/2"
7/16"
0.26
0.24
0.19
0.16
0.27
0.17
0.14
0.04
0.12
0.11
NOMINAL TAKE-OUTFITTINGNOMINAL SIZETYPE
PART
NUMBER (T/O)
2"
3/4"
1"
1-1/4"
1-1/2"
13/16"
80056
80055
3"
2-1/2"
1.191"
0.89
80
40
80
40
40
80
80
REDUCING COUPLING
2"
3/4"
1"
1-1/4"
1-1/2"
1/4"
80081
80080
3"
2-1/2"
0.913/16"
0.67
80
40
80
40
40
80
80
80220 0.081" x 3/4"
1/8"40
80
40
80
40
40
80
80
80
80
80
80
80
80
80
80
80
80215 2-1/2" x 1" 15/16"
0.42
80214 2-1/2" x 1-1/4" 13/16"
0.45
80213 2-1/2" x 1-1/2" 11/16"
0.46
80211 2-1/2" x 2"
5/8"0.29
80210 3" x 2"
3/4"0.72
80212 3" x 2-1/2"
1/2"0.47
WEIGHT
(lb.)SCHD.
T/O
80104
80103
80102
CAP
80101
80100
2"
1-1/4"
1-1/2"
3/4"
1"
5/8"
11/16"
7/16"
0.31
0.20
0.10
5/16"
3/8"0.06
0.04
80106
80105
3"
2-1/2"
1"
7/8"
0.88
0.58
80
40
80
40
40
80
80
1-1/4" x 1-1/4" Groove 2-5/16"
80161
80162
T/O
1-1/2" x 1-1/2" Groove
2" x 2" Groove 2-5/16"
2-5/16"
80160
COUPLING ADAPTER
0.95
1.42
0.78
GROOVED
80163 2-1/2" x 2-1/2" Groove 2-5/16"
2.28
80164 3" x 3" Groove 2-1/4"
3.00
80169 2-1/2" x 76,1 mm Groove 2-5/16"
2.28
40
80
80
80
80
80
PIPE
O.D.
T/O PIPE O.D.
1-1/4" (1.660")
2" (2.375")
1-1/2" (1.900")
2-1/2" (2.875")
3" (3.500")
76,1 mm (3.000")
TFP1915 Page5of6
3/4" x 3/4" NPT 13/16"
80145
80146
T/O
1' x 1" NPT
1-1/4" x 1-1/4" NPT 1-1/8"
7/8"
80142
0.63
1.03
0.41
80147 1-1/2" x 1-1/2" NPT 1-3/8"
1.42
80148 2" x 2" NPT 1-11/16" 2.66
40
40
80
40
80
3/4" x 3/4" NPT 1-5/16"
80158 1' x 1" NPT 1-3/8"
80157
0.56
0.3340
40
T/O
80177L 3/4" x 1/2" NPT
0.16401/2"
80178 1" x 1/2" NPT
0.20409/16"
T/O
80258
80253
80256
2" x 1-1/2" x 1/2" NPT
2" x 2" x 1/2" NPT
1-1/4" x 1" x 1/2" NPT
1/2"
1/2"
7/16"
1-11/16"5/8"
1/2" 1-11/16"
9/16" 1-5/16"
0.56
0.62
0.30
80250 3/4" x 3/4" x 1/2" NPT 9/16" 9/16"
1" 0.22
80251 11/16"1" x 1" x 1/2" NPT 11/16"
0.291-3/16"
80249 1" x 1" x 1" NPT 15/16" 15/16" 1-9/16"
0.73
80252 1-1/4" x 1-1/4" x 1/2" NPT 7/16"7/16"0.311-5/16"
80257 1-1/2" x 1-1/4" x 1/2" NPT 1/2" 11/16" 1-7/16"
0.43
1/2"1-1/2" x 1-1/2" x 1/2" NPT80254 1/2"
0.461-7/16"
80
80
40
40
40
40
40
80
80
T/OT/O
Z
XY
T/O
80175E 3/4" x 1/2" NPT
0.20
80176E 1" x 1/2" NPT
0.22
80
80
7/16"
7/16"
80175WL 3/4" x 1/2" NPT
0.16407/16"
80179 1" x 3/4" NPT
0.434013/16"
NOMINAL TAKE-OUTFITTINGNOMINAL SIZETYPE
PART
NUMBER (T/O)
FEMALE ADAPTER
MALE ADAPTER
WEIGHT
(lb.)SCHD.
ADAPTER (SPIGOT)
SPRINKLER HEAD
YXx YxZ XZ
ADAPTER TEE
SPRINKLER HEAD
ADAPTER
SPRINKLER HEAD
ADAPTER
SPRINKLER HEAD
80175W 3/4" x 1/2" NPT
0.19401/2"
80176W 1" x 1/2" NPT
0.18401/2"
T/O
T/O
80180 1" x 3/4" NPT
0.40407/8"
FIGURE 2 — FITTING DIMENSIONS (Part 3 of 4)
Limited
Warranty
Products manufactured by Tyco Fire &
Building Products (TFBP) are war-
ranted solely to the original Buyer for
ten (10) years against defects in mate-
rial and workmanship when paid for
and properly installed and maintained
under normal use and service. This
warranty will expire ten (10) years
from date of shipment by TFBP. No
warranty is given for products or com-
ponents manufactured by companies
not affiliated by ownership with TFBP
or for products and components which
havebeensubjecttomisuse,improper
installation,corrosion, or which have
not been installed, maintained, modi-
fied or repaired in accordance with ap-
plicable Standards of the National Fire
Protection Association, and/or the
standards of any other Authorities
Having Jurisdiction. Materials found
by TFBP to be defective shall be either
repaired or replaced, at TFBP’s sole
option. TFBP neither assumes, nor
authorizes any person to assume forit,
any other obligation in connection with
the sale of products or parts of prod-
ucts. TFBP shall not be responsible for
sprinkler system design errors or inac-
curate or incomplete information sup-
plied by Buyer or Buyer’s repre-
sentatives.
In no event shall TFBP be liable, in
contract, tort, strict liability or under
any other legal theory, for incidental,
indirect,specialorconsequentialdam-
ages, including but not limited to labor
charges, regardless of whether TFBP
was informed about the possibility of
such damages, and in no event shall
TFBP’s liability exceed an amount
equal to the sales price.
Theforegoingwarrantyismadeinlieu
of any and all other warranties, ex-
press or implied, including warranties
ofmerchantabilityandfitnessforapar-
ticular purpose.
This limited warranty sets forth the ex-
clusive remedy for claims based on
failure of or defect in products, materi-
als or components, whether the claim
is made in contract, tort, strict liability
or any other legal theory.
This warranty will apply to the full ex-
tent permitted by law. The invalidity, in
whole or part, of any portion of this
warranty will not affect the remainder.
Page6of6 TFP1915
TYCO FIRE & BUILDING PRODUCTS,451 North Cannon Avenue, Lansdale, Pennsylvania 19446
FIGURE 2 — FITTING DIMENSIONS (Part 4 of 4)
5/8"
5/8"
X Y, Z
1-5/16"
1-3/16"
Xx YxZ
80459 1" x 1/2" NPT x 1/2" NPT
0.48
80460 1" x 1/2" NPT x 1/2" NPT
0.46
40
40
BACK-TO-BACK TEE
T/O
T/OT/O
T/O
T/OT/O
T/O
Z
X
X
Z
W
Y
Y
5/8"
5/8"
X, Y Z, W
1-3/16"
1-5/16"
X x Y x Z x W
80462 1" x 1" x 1/2" NPT x 1/2" NPT
0.46
80463 1" x 1" x 1/2" NPT x 1/2" NPT
0.47
40
40
BACK-TO-BACK CROSS
NOMINAL TAKE-OUTFITTINGNOMINAL SIZETYPE
PART
NUMBER (T/O)
WEIGHT
(lb.)SCHD.
T/O
T/O
X
Y
ADAPTER 90° ELBOW
SPRINKLER HEAD
9/16"
3/4"
XY
1"
1-1/4"
XxY
80199 3/4" x 1/2" NPT
0.20
80198 1" x 1/2" NPT
0.26
40
40
1-1/16" 1-7/16"80196 1" x 3/4" NPT
0.2640
OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330
CUSTOMER SERVICE • 800.786.5266
www.tolco.com
42
www.tolco.com
Revision 1/21/2011
Fig. 28 - "Stand-Off" Hanger & Restrainer for
CPVC Plastic Pipe
Size Range — ¾" through 2"
Material — Carbon Steel, Pre-Galvanized
Function — Designed to be used as a hanger and restrainer for CPVC piping where
the "stand-off" design will ease installation by eliminating the need for wood blocking.
Features:
• Flared edge design protects CPVC pipe from any rough or abrasive surfaces.
• Unique twist and lock design holds pipe firmly in place and allows retrofit type
of installation.
• The "Stand-Off" design eliminates the need for wood block extension.
• Can be installed on horizontal or vertical piping regardless of mounting
surface orientation.
• Attaches easily to wood structure with two hex head self-threading screws
furnished with product.
• Installs easily using rechargeable electrical driver with 5/16" extension socket
eliminating impact tool damage to pipe.
• Attaches easily to steel, minimum 18 gauge with (2) 1/4" x 1" tek type self drilling
tapping screws.
• UL Listed as a hanger and a restrainer for fire sprinkler piping.
Approvals — Underwriters' Laboratory Listed in the USA (UL) and Canada (cUL) to
support automatic fire sprinkler systems. May be installed into wood using fasteners
supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1" tek type
screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satis-
fies the UL vertical restraint requirement where needed. UL Listed as a hanger and ver-
tical restraint when installed on 3/8" composite wood material. Use two Fig. 27B Speed
Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper
installed screw when used as a hanger only.
Order by — Figure number and pipe size.
Pat. # 7,455,268, Pat. # 7,832,248
Dimensions • Weights
Pipe Approx.
Size A B C Wt.
3/4 31⁄32 2 31⁄2 .180
1 35⁄16 23⁄16 31⁄2 .210
11⁄4 35⁄8 23⁄8 31⁄2 .225
11⁄2 4 21⁄2 31⁄2 .310
2 41⁄2 211⁄16 35⁄8 .340
If any questions or concerns please contact us.
Javier Cordova (760) 625-5908
Eric Franco (442) 307-1231
Kind Regards,
JC FIRE PROTECTION
@DEFG98H (&I)'&; #$$,&$A
!"#$ %&''&( #$ ) *&+,&$' -.( /0'&1$#.1 -.( 2&(3#' 4556768977:5 )' '"& );;(&$$ .-
<=>=6 B)((#$'. @#(A *&)$.1 -.( *&+,&$' .- /0'&1$#.1 #$ ;,& '. B(.C&?' $'.BB&; ;,& '.
TOLCO™Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe
Size Range:Available in 3/4"(20mm)and 1"(25mm)pipe sizes
Material:Pre-Galvanized Steel
Function:Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler
pipe. Provides double offset 11/2”(20mm)x 11/2”(20mm)from mounting surface. This design
will ease installation by eliminating the need for wood block extension and allow retro-fit
attachment of hanger to sprinkler pipe.
Features:
• Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not
required to be bent for listed installation.
• Offset edge eliminates abrasion.
• Attaches easily to wood structure with two special #10 x 1” hex head self-threading
screws furnished with product.
• Can be used as a single offset hanger by aligning "dimples" with top of mounting
surface and utilizing two fasteners in two of the three holes provided.
Approvals:Underwriters Laboratories Listed in the USA (UL)and Canada (cUL)as a
hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of
NFPA 13, 13R and 13D.
Finish:Pre-Galvanized
Order By:Part number and pipe size.
Patent Pending
Install using a rechargeable electric drill fitted with a 5/16” (7.9mm)socket attachment with the special hex head self-tapping
screws provided. Install screws until they bottom out. Pipe can be “snapped” into hanger before or after installation of
the screws to the mounting surface. “Thumb tab” may be bent up to provide additional protection to the pipe, but is not
required for performance of the hanger / restrainer function.
Double Offset
Single Offset
1.5”
(38.1mm)
1.5”
(38.1mm)
1.5”
(38.1mm)
1.5”
(38.1mm)Pipe Clamps Pipe Clamps
Pipe Size Approx. Wt./100
Part No.in. (mm) lbs. (kg)
29-3/4 3/4"(20)17.0 (7.7)
29-1 1"(25)18.6 (8.4)
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
103 B-Line series Pipe Hangers & SupportsEaton
DESIGN & DEVELOPMENT DEPARTMENT
78-495 Calle Tampico
La Quinta, California 92253
(760) 777-7125 / FAX (760) 777-7011
OFFICE USE ONLY:
REVIEW DATE: ______________
APPROVED CORRECTIONS
CALLED FOR PICKUP:_________
PICKED UP:_________________
SUBMITTAL #_________ REVISION #________ PERMIT NO.
APPLICANT/OWNER INFORMATION
Applicant Name: Owner Name:
Mailing Address: Site Address:
Phone Number: Project
Email:
Description: (Include # of sprinkler heads)
Pursuant to a Cooperative Agreement to Provide Fire Services, the Riverside County Fire Department serves as the City’s fire
department, and the County designee serves as the City’s fire chief. Applicant recognizes this contracted arrangement and
shall comply with County Fire Department directions.
CONTRACTOR INFORMATION
Contractor Name:
Contractor #: Signature:
Contact Person:
Mailing Address: Print Name:
City, State, Zip: Phone Number:
Business License #: Email Address:
------------ HOURLY@161/HR
$670 HOURLY@161/HR
$791
$992 $418
$1234 HOURLY@161/HR
$418
------------ HOURLY@161/HR
$418
$499 $740
$579 HOURLY@161/HR
------------ HOURLY@161/HR
$176 $901
$257 HOURLY@161/HR
$337 $659
$590 $579
$418
$418 $161
$1062 HOURLY@161/HR
1/29/2020
OFFICE OF THE FIRE MARSHAL – LA QUINTA
78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074
• www.rvcfire.org
March 18, 2021
JC Fire Protection
81705 De Oro Ave
Indio, CA 92201
Re: Residential Fire Sprinkler Plan Review – KRIEGENBERGH RESIDENCE REMODEL
FSS2021-0045 / 57872 BARRISTO CIRCLE, LA QUINTA, CA 92253
The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County
Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions.
Permanently marked identification signs shall be attached to all control valves.
The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff:
(a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal
operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the
potential to contact CPVC piping once insulation is installed.
(b) Final inspection
The Fire Department approved plans and conditions letter must be at the job site.
Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for
inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131.
All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal
staff at (760)777-7074.
Kohl Hetrick - Fire Safety Specialist
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
RIVERSIDE COUNTY FIRE PROTECTION PLANNING
RECORD OF INSPECTIONS / PERMIT CARD
THIS CARD IS TO REMAIN ON SITE AT ALL TIMES.
INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE.
JOB
ADDRESS: 57872 BARRISTO CIRCLE PERMIT#: FSS2021-0045 DATE
ISSUED: 3/18/2021
DESCRIPTION: KRIEGENBERGH REMODEL CONTRACTOR: JC FIRE PROTECTION
HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS
Thrust block pre-pour Door fan test
UG rough piping Abort test
UG hydro Mechanical shutdown
Flush Detector test
Final E F Deluge/pre-action
SPRINKLER U.G. Final E F
Thrust block pre-pour UST/AST TANK
UG rough piping Installation
UG hydro Removal
Flush Emergency shut off
Final E F Primary piping
FIRE SPRINKLER Secondary piping
Weld inspection Dispensers & shear valves
Overhead rough piping Final E F
Overhead hydro MISC. INSPECTIONS
UG flush / OK to connect Spray booths
Main drain/inspectors’ test Hood/duct extinguishing
High pile storage High pile rack storage
In-rack sprinklers H.P. vents/access/corridors
Hose racks Tract access/hydrant verification
Final E F Access & Address verification
HOOD EXTINGUISHING OTHER CONST. PERMIT
Detection system
Function test
Gas/electrical shut-off
Nozzle model/placement
Fire alarm connection
Final E F
SPRAY BOOTHS FIRE CODE PERMIT(S)
Installation
Air flow test
Mechanical interlock
Extinguishing system
Fire alarm connection
Final E F
FIRE ALARM KNOX SYSTEM
Rough-wire inspection Building Knox box
Function test Gate access Knox box/padlock
Duct detectors/velocity BUILDING INSPECTIONS
24 hr. battery test T/I final
Sprinkler monitoring Shell final
Final E F Final for occupancy
FINAL INSPECTION DATE: INSPECTORS SIGNATURE:
**WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE**
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
INSPECTION NOTES
1. Sway bracing and hangers will be inspected at the time of rough piping inspection.
2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler
Systems)
3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required.
4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test.
5. Contractor shall supply all testing equipment, access and operating instructions at time of test.
6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the
affected system to be covered or hidden.
POLICIES ON FIELD INSPECTIONS
A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when
scheduling inspections. For City of La Quinta inspections call: (760) 777-7131.
B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence
without approved plans.
C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required
to schedule the necessary inspections and be present on site for inspections.
D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not
on site or where previously noted corrections have not been completed.
E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into
the structure until clearance has been granted by the Fire Dept and Building Official.
F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance
has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official.
INSPECTION NOTES:
THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE
AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS.
THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180
DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE.
THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE
REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.