FSS2021-0045ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE JULIA AGGREH 1/20/2022 1/20/2022 CONTRACTOR REQUESTED FINAL INSPECTION. PERMIT EXPIRED AS OF 3/18/21 (6 MOS FROM DATE OF LAST APPROVED INSPECTION). ADDED EXTENSION FEE OF $83 AND EXTENDED PERMIT TO 1/21/22 SO CONTRACTOR CAN PAY FEE VIA ETRAKIT. WILL ALSO REQUIRE AN EXTENSION REQUEST LETTER FROM CONTRACTOR. OK TO EXTEND PER KOHL. CONTRACTOR SUBMITTED EXTENSION LETTER AND PAID FEE. EXTENDED PERMIT FOR ANOTHER 6 MOS FROM EXTENSION FEE PAYMENT. NOTE KAYLI ALFORD 3/18/2021 3/18/2021 ON HOLD UNTIL BUILDING PERMIT IS ISSUED. CANNOT HAVE FIRE SPRINKLER PERMIT WITHOUT BUILDING PERMIT ISSUED. CONTRACTOR WAS NOTIFIED VIA EMAIL. Description: adding 4 sprinkler heads to a existing home / BRES2020-0334 Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 3/4/2021 ECON Parcel No: 762500016 Site Address: 57872 BARRISTO CIR LA QUINTA,CA 92253 Approved: 3/18/2021 KHET Subdivision: TR 32225 Block: Lot: 16 Issued: 3/18/2021 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 1/27/2022 KHET Valuation: $1,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Monday, February 27, 2023 3:27:00 PM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0045 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 (760)625-5908 JCFIREPROTECTION@V ERIZON.NET CONTRACTOR J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 (760)625-5908 JCFIREPROTECTION@V ERIZON.NET OWNER ken von Kriegenbergh 57872 barristo circle la quinta CA 92253 (760)625-5908 kbvk1962@gmial.com NOTE KAYLI ALFORD 5/11/2021 5/11/2021 BUILDING PERMIT ISSUED AS OF 5/7/21. CHANGED STATUS OF THIS PERMIT FROM "ON HOLD" TO "ISSUED" AS OF 5/11/21 CONDITIONS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $161.00 $161.00 3/18/21 WEB7687 003126 CREDIT J C FIRE PROTECTION ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $242.00 $242.00 3/18/21 WEB7687 003126 CREDIT J C FIRE PROTECTION ECON FIRE STAFF - PER HOUR 101-0000-42420 1 $83.00 $83.00 1/20/22 WEB10429 634912794 54 CREDIT 996335 ECON Total Paid for FIRE FEES: $486.00 $486.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 3/18/21 WEB7687 003126 CREDIT J C FIRE PROTECTION ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 3/18/21 WEB7687 003126 CREDIT J C FIRE PROTECTION ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$501.00 $501.00 Printed: Monday, February 27, 2023 3:27:00 PM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0045 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 3/4/2021 EtrakitContractor 1ST SUBMITTAL PLAN scan0019 copy.pdf 1 DOC 3/4/2021 EtrakitContractor 1ST SUBMITTAL RFC SPRINKLERS Model_RFC_Residential _Concealed_Sprinkler.p df 1 DOC 3/4/2021 EtrakitContractor 1ST SUBMITTAL APPICATION FIRE APPLICATION SEPTEMBER 2019 FEE UPDATE REVISED 3 .pdf 1 DOC 3/4/2021 EtrakitContractor 1ST SUBMITTAL STAND OFF HANGER fig28 copy.pdf 1 DOC 3/4/2021 EtrakitContractor 1ST SUBMITTAL PIPE CLAMPS pc-cpvc-double-offset copy.pdf 1 BOND INFORMATION INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 5/12/2021 5/12/2021 APPROVED OVERHEAD HYRO KHET 5/12/2021 5/12/2021 APPROVED FIRE FINAL**KHET 1/27/2022 1/27/2022 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 3/4/2021 3/18/2021 3/18/2021 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH (1 DAY) AARON HICKSON 3/4/2021 3/5/2021 3/4/2021 COMPLETE PARENT PROJECTS Printed: Monday, February 27, 2023 3:27:00 PM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0045 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 3/4/2021 EtrakitContractor 1ST SUBMITTAL CPVC blazemaster.pdf 1 DOC 1/20/2022 JULIA AGGREH Request for Extension Letter FSS2021- 0045.pdf Request for Extension Letter FSS2021- 0045.pdf 0 DOC 3/18/2021 KOHL HETRICK FSS2021-0045 - APPROVED PLANS.pdf FSS2021-0045 - APPROVED PLANS.pdf 1 DOC 3/18/2021 KOHL HETRICK FSS2021-0045 - COA AND JOB CARD.pdf FSS2021-0045 - COA AND JOB CARD.pdf 1 Printed: Monday, February 27, 2023 3:27:00 PM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0045 FSS2021-0045 Model RFC & G5 Cover Plate Model RFC43 & RFC43LLModel RFC30 & RFC30LL Model RFC49 & RFC49LL Model RFC58 Features • cULus Listed as Residential Sprinklers • Push-On cover plate installation • Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. In addition, Model RFCLL Series sprinklers are cULus Certified for Health Effects to NSF/ANSI standard 61 Annex G (LL) and Australian WaterMark Certified (WMCS). Model RFC30 sprinklers have a 165°F (74°C) temperature rated fusible-link operating element. Model RFC43, RFC49, RFC58, and RFC76 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link oper- ating element. Sprinklers with a 165°F (74°C) temperature rating are ordinary temperature classification and are listed for use with a 135°F (57°C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are inter- mediate temperature classification and are listed for use with a 165°F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC or Model G5 Cover Plate. Model G5 Cover Plates may be installed by either pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2” (13 mm) of cover plate adjustment. Model RFC58 and RFC76 sprinklers allow 3/4” (19 mm) of cover plate adjustment. Model RFC and G5 Cover Plates are available in a variety of finishes as listed in Table H. www.reliablesprinkler.com Sprinkler Model Nominal K-Factor gpm/psi1/2 (l/min/bar1/2) Max. Coverage Area ft x ft (m x m) Listings & Approvals Sprinkler Identification Number (SIN) RFC30 3.0 (43)14 x 14 (4.3 x 4.3)cULus RA0611 RFC30LL 3.0 (43)14 x 14 (4.3 x 4.3)cULus, LL, WMCS RA3211 RFC43 4.3 (62)20 x 20 (6.1 x 6.1)cULus RA0612 RFC43LL 4.3 (62)20 x 20 (6.1 x 6.1)cULus, LL, WMCS RA3212 RFC49 4.9 (71)20 x 20 (6.1 x 6.1)cULus RA0616 RFC49LL 4.9 (71)20 x 20 (6.1 x 6.1)cULus, LL, WMCS RA3216 RFC58 5.8 (84)20 x 20 (6.1 x 6.1)cULus RA0613 RFC76 7.6 (109)20 x 20 (6.1 x 6.1)cULus RA0618 Table A cULus: cULus Listed to UL1626, Residential Sprinklers for Fire Protection Service. LL: cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content). WMCS: Australian WaterMark Certified. Model RFC76 cULus Listed Model RFC Series Residential Sprinklers Flat Concealed Pendent Bulletin 006 September 2020 Bulletin 006 September 2020 Page 2 of 8 www.reliablesprinkler.com Model RFC30 & RFC30LL Sprinkler Components and Dimensions Figure 1 Model RFC30 and RFC30LL Sprinkler Hydraulic Design Criteria Table B Minimum Flow and Residual Pressure (1) Max. Coverage Area (2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) 12 x 12 (3.6 x 3.6) 9 (34) 9.0 (0.62) 14 x 14 (4.3 x 4.3) 10 (38) 11.0 (0.76) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table B above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Technical Specifications Style: Flat Concealed Pendent Threads: 1/2” NPT or ISO 7-1R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating 165°F (74°C) sprinkler 135°F (57°C) cover plate Cover Plate Model RFC Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC30LL only) Watermark Certified (RFC30LL only) Bottom View Model RFC30 & RFC30LL Residential Sprinklers RFC30: SINRA0611 RFC30LL: SINRA3211 Bulletin 006 September 2020 Page 3 of 8 www.reliablesprinkler.com Model RFC43 & RFC43LL Sprinkler Hydraulic Design Criteria Table C Minimum Flow and Residual Pressure (1) Max. Coverage Area (2) ft. x ft. (m x m) Ordinary Temperature Intermediate Temperature Flow gpm (l/min) Pressure psi (bar) Flow gpm (l/min) Pressure psi (bar) 15 x 15 (4.6 x 4.6) 12 (45) 7.8 (0.54) 12 (45) 7.8 (0.54) 16 x 16 (4.9 x 4.9) 13 (49) 9.1 (0.63) 13 (49) 9.1 (0.63) 18 x 18 (5.5 x 5.5) 18 (68) 17.5 (1.21)---- 20 x 20 (6.1 x 6.1) 21 (79) 23.8 (1.64)---- Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table C above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Model RFC43 & RFC43LL Sprinkler Components and Dimensions Figure 2 Technical Specifications Style: Flat Concealed Pendent Threads: 1/2” NPT or ISO 7-1R1/2 Nominal K-Factor: 4.3 (62 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC43LL only) Watermark Certified (RFC43LL only) Bottom View Model RFC43 & RFC43LL Residential Sprinklers RFC43: SINRA0612 RFC43LL: SINRA3212 Technical Specifications Style: Flat Concealed Pendent Threads: 1/2” NPT or ISO 7-1R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC49LL only) Watermark Certified (RFC49LL only) Model RFC49 & RFC49LL Sprinkler Components and Dimensions Figure 3 Model RFC49 & RFC49LL Sprinkler Hydraulic Design Criteria Table D Minimum Flow and Residual Pressure (1) Max. Coverage Area (2) ft. x ft. (m x m) Ordinary Temperature Intermediate Temperature Flow gpm (l/min) Pressure psi (bar) Flow gpm (l/min) Pressure psi (bar) 16 x 16 (4.9 x 4.9) 13 (49.0) 7.0 (0.48) 13 (49.0) 7.0 (0.48) 18 x 18 (5.5 x 5.5) 17 (64.3) 12.0 (0.83) 17 (64.3) 12.0 (0.83) 20 x 20 (6.1 x 6.1) 20 (75.7) 16.7 (1.15) 21 (79.5) 18.4 (1.27) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 September 2020 Page 4 of 8 www.reliablesprinkler.com Bottom View Model RFC49 & RFC49LL Residential Sprinklers RFC49: SINRA0616 RFC49LL: SINRA3216 Model RFC58 Residential Sprinkler SIN RA0613 Technical Specifications Style: Flat Concealed Pendent Threads: 1/2” NPT or ISO 7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Chrome Plated Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed Model RFC58 Sprinkler Components and Dimensions Figure 4 Model RFC58 Sprinkler Hydraulic Design Criteria Table E Minimum Flow and Residual Pressure( 1) Max. Coverage Area (2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) 16 x 16 (4.9 x 4.9) 16 (60.6) 7.6 (0.53) 18 x 18 (5.5 x 5.5) 18 (68.1) 9.6 (0.66) 20 x 20 (6.1 x 6.1) 20 (75.7) 11.9 (0.82) Bulletin 006 September 2020 Page 5 of 8 www.reliablesprinkler.com Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bottom View Bulletin 006 September 2020 Page 6 of 8 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 3/4” NPT or ISO 7-1R3/4 Nominal K-Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed Model RFC76 Flat Concealed Sprinkler Hydraulic Design Criteria Table E Minimum Flow and Residual Pressure( 1) Max. Coverage Area (2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) 16 x 16 (4.9 x 4.9) 21 (79.5) 7.6 (0.52) 18 x 18 (5.5 x 5.5) 24 (90.8) 9.9 (0.68) 20 x 20 (6.1 x 6.1) 34 (128.7) 20 (1.4) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bottom View Model RFC76 Residential Sprinkler SIN RA0618 Model RFC76 Sprinkler Components and Dimensions Figure 5 Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(3)Custom Color Paint(2) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Custom color paint is semi-gloss, unless specified otherwise. 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the back side. Cover plates are not listed or approved as corrosion resistant. Cover Plate Finishes(1) Table H Bulletin 006 September 2020 Page 7 of 8 www.reliablesprinkler.com Notes: 1. Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2” x 1/2” brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. 2. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (38°C). 3. For use with 212°F (100°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F (66°C). Sprinkler Model Cover Plate Model Cover Plate Diameter inch (mm) Recommended Hole Diameter in Ceiling inch (mm) Cover Plate Adjustment inch (mm) Min. to Max. Face of Fitting to Ceiling(1) inch (mm) Min. to Max. Dropped Deflector Distance below Ceiling inch (mm) Cover Plate Temperature Rating RFC30, RFC30LL RFC or G5 3-5/16 (84) 2-5/8 (67) 1/2 (13) 1-1/2 to 2 (38 to 51) 1/2 to 1 (13 to 25) 135°F (57°C) RFC43, RFC43LL, RFC49, RFC49LL RFC or G5 3-5/16 (84) 2-5/8 (67) 1/2 (13) 1-1/2 to 2 (38 to 51) 1/2 to 1 (13 to 25) 135°F(2) (57°C) or 165°F(3) (74°C) RFC58, RFC76 RFC or G5 3-5/16 (84) 2-5/8 (67) 3/4 (19) 1-1/2 to 2-1/4 (38 to 57) 1/4 to 1 (6 to 25) 135°F(2) (57°C) or 165°F(3) (74°C) Table JInstallation Dimensions Installation Model RFC series sprinklers are intended to be installed in accordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Model RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a wrench-able protective cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model RFC series sprinklers can be installed without removing the wrench-able protective cap using the Model W3 wrench. Alternatively, Model RFC series sprinklers can be installed using the Model FC wrench by temporarily removing the protective cap during installation of the sprinkler. The use of any other wrench to installed Model RFC series sprinklers is not permitted and may damage the sprinkler. Fully insert the Model W3 wrench over the cap until it reaches the bottom of the cup, or the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model W3 and FC wrenches are designed to be turned with a standard 1/2” square drive. Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler’s threads. Recommended installation torque is 8 to 18 ft-lbs (11 to 24 N-m) for 1/2” thread sprinklers and 14 to 20 ft-lbs (19 to 27 N-m) for 3/4” thread sprinklers. Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or impairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pendent residential sprinklers. Model RFC 30 and RFC30LL sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C). Model RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are available in either ordinary or intermediate temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (66°C), respectively. Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada to UL1626, Residential Sprinklers for Fire-protection Service (cULus). Certified by Underwriters Laboratories, Inc. and Underwrit- ers Laboratories of Canada for Health Effects to NSF/ANSI Standard 61 Annex G (LL) (RFC30LL, RFC43LL, and RFC49LL only). Australian WaterMark Certified (RFC30LL, RFC43LL, and RFC49LL only). Patents Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler • Model (RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, RFC76) • Temperature Rating Cover Plate • Model RFC or G5 • Temperature Rating • Finish (See Table H) Sprinkler Wrench • Model FC • Model W3 • Model W8 (Limited use) Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-oper- ation. Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Bulletin 006 September 2020 Page 8 of 8 www.reliablesprinkler.com P/N 9999970261Model FC For use with Model RFC Series sprinklers without wrench-able cap installed Installation Wrenches Model W3 For use with Model RFC Series sprinklers with wrench-able cap installed Model W8 High-strength plastic wrench for limited (emergency) use with Model RFC Series sprinklers without wrench-able cap installed. Meets NFPA requirements for sprinkler wrench on premises. Service/Spare Head Cabinet Wrench General Description Tyco Fire & Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings are designed exclusively for use in wet pipe automatic fire sprinkler systems. They are made from a specially devel- oped thermoplastic compound com- posed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TFBP BlazeMaster CPVC products are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as com- pared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapters are available to connect CPVC pipe to metallic pip- ing. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. WARNING Tyco Fire & Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings described herein mustbe installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction.Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Sizes 3/4" to 3" Maximum Working Pressure 175 psi Approvals UL, FM, CUL, NSF, Dade County, LPCB, MEA, and the City of Los Ange- les. (Refer to IH-1900, Rev. 0, Janu- ary 2005 “Installation Instruction & Technical Handbook” for exact list- ing/approval information.) Manufacture Source U.S.A. Material •Pipe: ASTM F442, SDR 13.5 •Fittings: ASTM F438 (Sch. 40) and ASTM F439 (Sch. 80), ASTM F1970 Color Orange BlazeMaster ® CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet Page 1 of 6 TFP1915JANUARY, 2006 Technical Services:Tel: (800) 381-9312 / Fax: (800) 791-5500 BlazeMaster®is a registered trademark of Noveon IP Holding Corp. Installation Tyco Fire and Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings are to be installed in accord- ance with IH-1900, Rev. 0, January 2005“Installation Instruction &Techni- cal Handbook”. Care and Maintenance The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stallingcontractor orproductmanufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise thoseresponsibleformoni- toring proprietary and/or central sta- tion alarms. Page2of6 TFP1915 FIGURE 1 — PIPE DIMENSIONS 2" 1" 1-1/4" 1-1/2" 3/4" 2.375" 2.003" 1.315" 1.660" 1.900" 1.050" 1.101' 1.394" 1.598" 0.874" SIZE NOMINAL 2.200.84 0.67 0.44 1.08 1.41 0.26 0.42 0.54 0.18 3" 2-1/2" 3.500" 2.952" 2.875" 2.423" 4.831.87 3.261.26 10841260 1320 1339 1191 1213 5040 2835 2205 7875 1344720 15311215 O.D. AVERAGE lbs./ft. WEIGHTAVERAGE I.D.FILLED WEIGHT WATER lbs./ft. FT. OF PIPE PER LIFT WEIGHT PER LIFT lbs. TFP1915 Page3of6 FIGURE 2 — FITTING DIMENSIONS (Part 1 of 4) NOMINAL TAKE-OUTFITTINGNOMINAL SIZETYPE PART NUMBER (T/O) T/O T/O 80004 80003 80002 TEE T/O 80001 80000 2" 1-1/4" 1-1/2" 3/4" 1" 1-3/8" 1-1/16" 7/8" 0.90 0.51 0.26 5/8" 11/16"0.19 0.11 REDUCING TEE 1-1/2" x 1-1/2" x 1-1/4" 80266 80267 80274 80264 80275 80261 80262 80263 80260 2" x 2" x 3/4" 2" x 2" x 1" 2" x 2" x 1-1/2" 1-1/2" x 1-1/2" x 1" 7/8" 1-1/8" 1-1/16" 7/8" 9/16" 1-1/2" x 1-1/2" x 3/4" 1-1/4" x 1-1/4" x 3/4" 1-1/4" x 1-1/4" x 1" 1" x 1" x 3/4" 5/8" 9/16" 3/4" 5/8" 1-3/8" 1-3/8" 1-3/8" 7/8" 9/16" 1" 1-1/16" 0.66 0.78 0.74 0.45 0.38 7/8"5/8" 9/16" 3/4" 1" 7/8" 5/8" 13/16" 0.23 0.36 0.26 0.16 YXx YxZ XZ 80132 3/4" x 3/4" x 1" 3/4" 3/4" 5/8" 0.14 80133 9/16"1" x 3/4" x 3/4" 9/16" 0.143/4" 80134 1" x 3/4" x 1" 3/4" 11/16" 3/4" 0.17 80135 1-1/4" x 1" x 3/4" 5/8"5/8"0.2115/16" 80136 1-1/4" x 1" x 1" 3/4" 3/4" 15/16" 0.22 15/16"1-1/4" x 1" x 1-1/4"80137 15/16" 0.267/8" 80138 1-1/4" x 1-1/4" x 1-1/2" 1" 1" 1" 0.43 80140 1-1/2" x 1-1/4" x 3/4" 9/16" 9/16" 1" 0.36 1-1/2" x 1-1/4" x 1"80141 9/16" 9/16" 0.381-1/16" 80265 3/4" 1-3/8" 0.61 T/O T/O T/O X Y Z 7/8" 1-1/8" 1-1/16" 3/4" WEIGHT (lb.) T/O T/O T/O T/O CROSS & REDUCING CROSS 1-1/16" 80009 80010 80011 80013 80012 0.139/16" 1-5/16" 11/16" 15/16" 1.00 0.23 0.34 0.67 80006 80005 3" 2-1/2" 1-13/16" 1-9/16" 2.41 1.59 2-1/2" x 2-1/2" x 1-1/2" 80270 80269 80268 80272 80273 80271 3" x 3" x 1-1/2" 3" x 3" x 2" 3" x 3" x 2-1/2" 2-1/2" x 2-1/2" x 1-1/4" 1-13/16" 1-13/16" 1-13/16" 1-9/16" 1-9/16" 2-1/2" x 2-1/2" x 1" 1-9/16" 1-13/16" 1-13/16" 1-3/4" 1-9/16" 1-9/16" 1-9/16" 1-9/16" 2.28 2.44 2.25 1.48 1.46 1-9/16" 1-9/16" 1.43 80276 2-1/2" x 2-1/2" x 2" 1-9/16" 1-9/16" 1.50 1-13/16" 1-13/16" 1-13/16" 1-9/16" 2" x 2" x 1-1/4" 1-9/16" 80008 80014 1-13/16" 2.89 1.91 2" 1-1/4" 1-1/2" 3/4" 1" 3" 2-1/2" 80015 0.281" x 1" x 3/4" x 3/4" 7/8" SCHD. 80 40 80 40 40 80 80 80 80 80 80 40 40 40 40 40 40 40 40 40 80 80 80 80 80 80 80 80 80 80 80 80 80 80 40 80 40 40 80 80 40 T/O T/O 90° ELBOW & 1-1/16" 80029 80026 80025 80027 80028 2" 3/4" 1" 1-1/4" 1-1/2" 0.791-5/16" 5/8" 3/4" 7/8"0.21 0.14 0.40 0.09 Y X 1-9/16" 80031 80030 3" 2-1/2" 1.821-13/16" 1.14 XxY 80032 1" x 3/4" 0.16 X 11/16" Y 13/16" REDUCING ELBOW 80 40 80 40 40 80 80 40 Page4of6 TFP1915 FIGURE 2 — FITTING DIMENSIONS (Part 2 of 4) 0.2580078 T/O 80079 0.38 T/O COUPLING & T/O 45° ELBOW 80053 80054 80075 80076 80077 80050 80051 80052 0.311/2" 1/8" 3/4" 0.11 0.07 0.12 0.56 3/8" 3/8" 3/4" 0.08 0.11 0.20 1/8" 3/16" 3/16" 3/16" 80203 80206 80205 80204 80200 80201 80202 80207 80208 80209 T/O REDUCER BUSHING 2" x 1-1/4" 2" x 1-1/2" 2" x 1" 1-1/2" x 3/4" 1-1/2" x 1-1/4" 1-1/4" x 3/4" 1-1/2" x 1" 2" x 3/4" 1-1/4" x 1" 1" x 3/4" 11/16" 9/16" 7/16" 5/8" 1/2" 13/16" 3/8" 5/16" 1/2" 7/16" 0.26 0.24 0.19 0.16 0.27 0.17 0.14 0.04 0.12 0.11 NOMINAL TAKE-OUTFITTINGNOMINAL SIZETYPE PART NUMBER (T/O) 2" 3/4" 1" 1-1/4" 1-1/2" 13/16" 80056 80055 3" 2-1/2" 1.191" 0.89 80 40 80 40 40 80 80 REDUCING COUPLING 2" 3/4" 1" 1-1/4" 1-1/2" 1/4" 80081 80080 3" 2-1/2" 0.913/16" 0.67 80 40 80 40 40 80 80 80220 0.081" x 3/4" 1/8"40 80 40 80 40 40 80 80 80 80 80 80 80 80 80 80 80 80215 2-1/2" x 1" 15/16" 0.42 80214 2-1/2" x 1-1/4" 13/16" 0.45 80213 2-1/2" x 1-1/2" 11/16" 0.46 80211 2-1/2" x 2" 5/8"0.29 80210 3" x 2" 3/4"0.72 80212 3" x 2-1/2" 1/2"0.47 WEIGHT (lb.)SCHD. T/O 80104 80103 80102 CAP 80101 80100 2" 1-1/4" 1-1/2" 3/4" 1" 5/8" 11/16" 7/16" 0.31 0.20 0.10 5/16" 3/8"0.06 0.04 80106 80105 3" 2-1/2" 1" 7/8" 0.88 0.58 80 40 80 40 40 80 80 1-1/4" x 1-1/4" Groove 2-5/16" 80161 80162 T/O 1-1/2" x 1-1/2" Groove 2" x 2" Groove 2-5/16" 2-5/16" 80160 COUPLING ADAPTER 0.95 1.42 0.78 GROOVED 80163 2-1/2" x 2-1/2" Groove 2-5/16" 2.28 80164 3" x 3" Groove 2-1/4" 3.00 80169 2-1/2" x 76,1 mm Groove 2-5/16" 2.28 40 80 80 80 80 80 PIPE O.D. T/O PIPE O.D. 1-1/4" (1.660") 2" (2.375") 1-1/2" (1.900") 2-1/2" (2.875") 3" (3.500") 76,1 mm (3.000") TFP1915 Page5of6 3/4" x 3/4" NPT 13/16" 80145 80146 T/O 1' x 1" NPT 1-1/4" x 1-1/4" NPT 1-1/8" 7/8" 80142 0.63 1.03 0.41 80147 1-1/2" x 1-1/2" NPT 1-3/8" 1.42 80148 2" x 2" NPT 1-11/16" 2.66 40 40 80 40 80 3/4" x 3/4" NPT 1-5/16" 80158 1' x 1" NPT 1-3/8" 80157 0.56 0.3340 40 T/O 80177L 3/4" x 1/2" NPT 0.16401/2" 80178 1" x 1/2" NPT 0.20409/16" T/O 80258 80253 80256 2" x 1-1/2" x 1/2" NPT 2" x 2" x 1/2" NPT 1-1/4" x 1" x 1/2" NPT 1/2" 1/2" 7/16" 1-11/16"5/8" 1/2" 1-11/16" 9/16" 1-5/16" 0.56 0.62 0.30 80250 3/4" x 3/4" x 1/2" NPT 9/16" 9/16" 1" 0.22 80251 11/16"1" x 1" x 1/2" NPT 11/16" 0.291-3/16" 80249 1" x 1" x 1" NPT 15/16" 15/16" 1-9/16" 0.73 80252 1-1/4" x 1-1/4" x 1/2" NPT 7/16"7/16"0.311-5/16" 80257 1-1/2" x 1-1/4" x 1/2" NPT 1/2" 11/16" 1-7/16" 0.43 1/2"1-1/2" x 1-1/2" x 1/2" NPT80254 1/2" 0.461-7/16" 80 80 40 40 40 40 40 80 80 T/OT/O Z XY T/O 80175E 3/4" x 1/2" NPT 0.20 80176E 1" x 1/2" NPT 0.22 80 80 7/16" 7/16" 80175WL 3/4" x 1/2" NPT 0.16407/16" 80179 1" x 3/4" NPT 0.434013/16" NOMINAL TAKE-OUTFITTINGNOMINAL SIZETYPE PART NUMBER (T/O) FEMALE ADAPTER MALE ADAPTER WEIGHT (lb.)SCHD. ADAPTER (SPIGOT) SPRINKLER HEAD YXx YxZ XZ ADAPTER TEE SPRINKLER HEAD ADAPTER SPRINKLER HEAD ADAPTER SPRINKLER HEAD 80175W 3/4" x 1/2" NPT 0.19401/2" 80176W 1" x 1/2" NPT 0.18401/2" T/O T/O 80180 1" x 3/4" NPT 0.40407/8" FIGURE 2 — FITTING DIMENSIONS (Part 3 of 4) Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which havebeensubjecttomisuse,improper installation,corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP’s sole option. TFBP neither assumes, nor authorizes any person to assume forit, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer’s repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect,specialorconsequentialdam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP’s liability exceed an amount equal to the sales price. Theforegoingwarrantyismadeinlieu of any and all other warranties, ex- press or implied, including warranties ofmerchantabilityandfitnessforapar- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Page6of6 TFP1915 TYCO FIRE & BUILDING PRODUCTS,451 North Cannon Avenue, Lansdale, Pennsylvania 19446 FIGURE 2 — FITTING DIMENSIONS (Part 4 of 4) 5/8" 5/8" X Y, Z 1-5/16" 1-3/16" Xx YxZ 80459 1" x 1/2" NPT x 1/2" NPT 0.48 80460 1" x 1/2" NPT x 1/2" NPT 0.46 40 40 BACK-TO-BACK TEE T/O T/OT/O T/O T/OT/O T/O Z X X Z W Y Y 5/8" 5/8" X, Y Z, W 1-3/16" 1-5/16" X x Y x Z x W 80462 1" x 1" x 1/2" NPT x 1/2" NPT 0.46 80463 1" x 1" x 1/2" NPT x 1/2" NPT 0.47 40 40 BACK-TO-BACK CROSS NOMINAL TAKE-OUTFITTINGNOMINAL SIZETYPE PART NUMBER (T/O) WEIGHT (lb.)SCHD. T/O T/O X Y ADAPTER 90° ELBOW SPRINKLER HEAD 9/16" 3/4" XY 1" 1-1/4" XxY 80199 3/4" x 1/2" NPT 0.20 80198 1" x 1/2" NPT 0.26 40 40 1-1/16" 1-7/16"80196 1" x 3/4" NPT 0.2640 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 42 www.tolco.com Revision 1/21/2011 Fig. 28 - "Stand-Off" Hanger & Restrainer for CPVC Plastic Pipe Size Range — ¾" through 2" Material — Carbon Steel, Pre-Galvanized Function — Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off" design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces. • Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation. • The "Stand-Off" design eliminates the need for wood block extension. • Can be installed on horizontal or vertical piping regardless of mounting surface orientation. • Attaches easily to wood structure with two hex head self-threading screws furnished with product. • Installs easily using rechargeable electrical driver with 5/16" extension socket eliminating impact tool damage to pipe. • Attaches easily to steel, minimum 18 gauge with (2) 1/4" x 1" tek type self drilling tapping screws. • UL Listed as a hanger and a restrainer for fire sprinkler piping. Approvals — Underwriters' Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satis- fies the UL vertical restraint requirement where needed. UL Listed as a hanger and ver- tical restraint when installed on 3/8" composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper installed screw when used as a hanger only. Order by — Figure number and pipe size. Pat. # 7,455,268, Pat. # 7,832,248 Dimensions • Weights Pipe Approx. Size A B C Wt. 3/4 31⁄32 2 31⁄2 .180 1 35⁄16 23⁄16 31⁄2 .210 11⁄4 35⁄8 23⁄8 31⁄2 .225 11⁄2 4 21⁄2 31⁄2 .310 2 41⁄2 211⁄16 35⁄8 .340 If any questions or concerns please contact us. Javier Cordova (760) 625-5908 Eric Franco (442) 307-1231 Kind Regards, JC FIRE PROTECTION @DEFG98H (&I)'&; #$$,&$A !"#$ %&''&( #$ ) *&+,&$' -.( /0'&1$#.1 -.( 2&(3#' 4556768977:5 )' '"& );;(&$$ .- <=>=6 B)((#$'. @#(A *&)$.1 -.( *&+,&$' .- /0'&1$#.1 #$ ;,& '. B(.C&?' $'.BB&; ;,& '. TOLCO™Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe Size Range:Available in 3/4"(20mm)and 1"(25mm)pipe sizes Material:Pre-Galvanized Steel Function:Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 11/2”(20mm)x 11/2”(20mm)from mounting surface. This design will ease installation by eliminating the need for wood block extension and allow retro-fit attachment of hanger to sprinkler pipe. Features: • Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not required to be bent for listed installation. • Offset edge eliminates abrasion. • Attaches easily to wood structure with two special #10 x 1” hex head self-threading screws furnished with product. • Can be used as a single offset hanger by aligning "dimples" with top of mounting surface and utilizing two fasteners in two of the three holes provided. Approvals:Underwriters Laboratories Listed in the USA (UL)and Canada (cUL)as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish:Pre-Galvanized Order By:Part number and pipe size. Patent Pending Install using a rechargeable electric drill fitted with a 5/16” (7.9mm)socket attachment with the special hex head self-tapping screws provided. Install screws until they bottom out. Pipe can be “snapped” into hanger before or after installation of the screws to the mounting surface. “Thumb tab” may be bent up to provide additional protection to the pipe, but is not required for performance of the hanger / restrainer function. Double Offset Single Offset 1.5” (38.1mm) 1.5” (38.1mm) 1.5” (38.1mm) 1.5” (38.1mm)Pipe Clamps Pipe Clamps Pipe Size Approx. Wt./100 Part No.in. (mm) lbs. (kg) 29-3/4 3/4"(20)17.0 (7.7) 29-1 1"(25)18.6 (8.4) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 103 B-Line series Pipe Hangers & SupportsEaton DESIGN & DEVELOPMENT DEPARTMENT 78-495 Calle Tampico La Quinta, California 92253 (760) 777-7125 / FAX (760) 777-7011 OFFICE USE ONLY: REVIEW DATE: ______________  APPROVED  CORRECTIONS CALLED FOR PICKUP:_________ PICKED UP:_________________  SUBMITTAL #_________  REVISION #________ PERMIT NO. APPLICANT/OWNER INFORMATION Applicant Name: Owner Name: Mailing Address: Site Address: Phone Number: Project Email: Description: (Include # of sprinkler heads) Pursuant to a Cooperative Agreement to Provide Fire Services, the Riverside County Fire Department serves as the City’s fire department, and the County designee serves as the City’s fire chief. Applicant recognizes this contracted arrangement and shall comply with County Fire Department directions. CONTRACTOR INFORMATION Contractor Name: Contractor #: Signature: Contact Person: Mailing Address: Print Name: City, State, Zip: Phone Number: Business License #: Email Address: ------------ HOURLY@161/HR $670 HOURLY@161/HR $791 $992 $418 $1234 HOURLY@161/HR $418 ------------ HOURLY@161/HR $418 $499 $740 $579 HOURLY@161/HR ------------ HOURLY@161/HR $176 $901 $257 HOURLY@161/HR $337 $659 $590 $579 $418 $418 $161 $1062 HOURLY@161/HR 1/29/2020 OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org March 18, 2021 JC Fire Protection 81705 De Oro Ave Indio, CA 92201 Re: Residential Fire Sprinkler Plan Review – KRIEGENBERGH RESIDENCE REMODEL FSS2021-0045 / 57872 BARRISTO CIRCLE, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 57872 BARRISTO CIRCLE PERMIT#: FSS2021-0045 DATE ISSUED: 3/18/2021 DESCRIPTION: KRIEGENBERGH REMODEL CONTRACTOR: JC FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.