Loading...
FSS2021-0051ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT Ernest pedraza 1018 e palm ave redlands CA 92374 (760)340-3602 fireprospecialist@yaho o.com CONTRACTOR FIRE PROTECTION SPECIALISTS P O BOX 381 REDLANDS CA 92373 (760)340-3602 FPS.FIRE@HOTMAIL.C OM OWNER TOMA STOIANOVICI 40462 CORTE PLACITAS PALM DESERT CA 92260 (760)340-3602 CONDITIONS Description: TANNER / FIRE SPRINKLERS / BRES2020-0242 Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 3/26/2021 EPRS Parcel No: 770106007 Site Address: 78668 CALLE TAMPICO LA QUINTA,CA 92253 Approved: 4/8/2021 KHET Subdivision: DESERT CLUB TR UNIT 5 Block: Lot: 121 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 9/15/2021 KHET Valuation: $3,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Monday, February 27, 2023 3:48:56 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0051 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 5/27/2021 5/27/2021 APPROVED See Inspection notes for minor corrections to confirm at final. OVERHEAD HYRO KHET 5/27/2021 5/27/2021 APPROVED FIRE FINAL**KHET 9/8/2021 9/8/2021 DISAPPROVE D Replace 2 painted heads in single garage. 200F needed in Pantry due to HVAC. 18" clearance from smoke Detector in long hallway. FIRE FINAL**KHET 9/15/2021 9/15/2021 APPROVED DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $161.00 $161.00 9/10/21 WEB9275 632411797 68 CREDIT 738506 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $161.00 $161.00 5/25/21 WEB8331 132435 CREDIT Ernest pedraza EPRS FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $242.00 $242.00 5/25/21 WEB8331 132435 CREDIT Ernest pedraza EPRS Total Paid for FIRE FEES: $564.00 $564.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 5/25/21 WEB8331 132435 CREDIT Ernest pedraza EPRS Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 5/25/21 WEB8331 132435 CREDIT Ernest pedraza EPRS Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$579.00 $579.00 Printed: Monday, February 27, 2023 3:48:56 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0051 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 3/26/2021 EtrakitPublicReg 1ST SUBMITTAL PLANS REV0_Tanner Residence Sprinkler Plans - 3-26- 2021.pdf 1 DOC 3/26/2021 EtrakitPublicReg 1ST SUBMITTAL HYDRAULIC CALCS REV0_Tanner Residence Calc Package - 3-26- 2021.pdf 1 DOC 4/8/2021 KOHL HETRICK FSS2021-0051 - APPROVED PLANS AND CALCS.pdf FSS2021-0051 - APPROVED PLANS AND CALCS.pdf 1 DOC 4/8/2021 KOHL HETRICK FSS2021-0051 - COA AND JOB CARD.pdf FSS2021-0051 - COA AND JOB CARD.pdf 1 DOC 5/27/2021 KOHL HETRICK FSS2021-0051 - INSP NOTES.pdf FSS2021-0051 - INSP NOTES.pdf 1 BOND INFORMATION REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 3/26/2021 4/9/2021 4/8/2021 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 3/26/2021 3/29/2021 3/29/2021 COMPLETE PARENT PROJECTS Printed: Monday, February 27, 2023 3:48:56 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0051 FSS2021-0051 SPRINKLERS SHALL NOT BE REQUIRED INCLOTHES CLOSETS, LINEN CLOSETS, ANDPANTRIES THAT MEET THE FOLLOWINGCONDITIONS: THE AREA OF THE SPACEDOESN'T EXCEED 24 SQ. FT. (NFPA 13D 8.3.3)SPRINKLERS SHALL NOT BE REQUIRED INBATHROOMS OF 55 SQ. FT. AND LESS. (NFPA13D 8.3.2)21SPRINKLERS SHALL NOT BE REQUIRED INCOVERED, UNHEATED PROJECTIONS OF THEBUILDING AT ENTRANCES/EXITS AS LONGAS THE DWELLING UNIT HAS ANOTHERMEANS OF EGRESS (NFPA 13D 8.3.6)34HEAT ZONE - SPRINKLER HEADS IN THISA R E A S H A L L B E I N T E R M E D I A T ET E M P E R A T U R ESDFANCEILING MOUNTED HEAT LAMPCEILING MOUNTED LIGHT FIXTURECEILING MOUNTED SMOKE DETECTORCEILING MOUNTED EXHAUST FANWALL MOUNTED LIGHT FIXTURECMWALL CARBON MONOXIDE ALARMSYSTEM RISERCPVC HANGER & RESTRAINERS (FIG. 188R) (FIG. 184) (FIG. 186) (FIG. 187)FLAT CONCEALED RESIDENTIAL PENDANT 16514'X14' SPACING (7'-0" OFF WALL MAX)NFPA 13D SHEET NOTESSYMBOL LEGENDHEAT ZONEVERTICAL SUPPLY8" FIRE ALARM BELL (WIRING BY OTHERS)SPRINKLER ABOVE FAU IN ATTICCEILING FANSURFACE MOUNTED FLUORESCENT SEMI RECESSED RESIDENTIAL PENDANT 175FLAT CONCEALED RESIDENTIAL PENDANT 16520'X20' SPACING (10'-0" OFF WALL MAX)14'X14' SPACING (7'-0" OFF WALL MAX)SSQR BRASS UPRIGHT ABOVE FAU 200150 SQ. FT. SPACING1. ALL PIPING SHALL BE 1" UNO2. ALL PIPING SHALL BE CPVC UNO3. ALL EXPOSED PIPING SHALL BE COPPER PIPE4. SEE RCP PLAN FOR EXACT HEAD LOCATION,COORDINATION & DIMENSIONS FROM WALLS5. CEILING HEIGHTS ARE NOTED IN THE RCP PLAN &BUILDING CROSS SECTION6. ALL WALLS ARE FULL HEIGHT WALLS UNO7. ALL WALL OPENINGS ARE 8'-0" IN HEIGHT UNOSYSTEM NOTES201 14" CopRISER DETAILSUPPLY TO O/H SPRINKLER SYSTEM1FLOW SWITCH CONNECTED TO 8" BELL21" IN LINE CHECK VALVE3PRESSURE GAUGE 0-300 PSI41" SYSTEM TEST & DRAIN 12" BALL VALVE5DRAIN TO APPROVED LOCATION6789SUPPLY TO DOMESTIC SYSTEM INSTALLED1 14" COP SWEEP1" CPVC 1Foundation1'-0" AFF 3'-0" BelowGrade 3546781 1 4" Cop "M"91 1/4" PVC22SET DELAY BETWEEN 15 & 60 SECONDSPER 2019 PLUMBING CODETRANSITION TO 1" COPTRANSITION TO 1" CPVC1 14" PVC SUPPLY FROM UNDERGROUNDSEE SHEET FP-1.0 FOR UNDG PIPING2FRONTSIDENominalPipe Size3⁄4DN201DN251-1⁄4DN321-1⁄2 - 3DN40 - DN80MAX.NOne-PointVerticalRESTRAINTONE-POINTRestraintONE-POINTRESTRAINTTable R - One Point of Restraint“N”ANSI InchesDNLess than100 psi(6,9 bar)0’-9”(0,23 m)1’-0”(0,30 m)1’-4”(0,41 m)2’-0”(0,61 m)“N”Greater than100 psi(6,9 bar)0’-6”(0,15 m)0’-9”(0,23 m)1’-0”(0,30 m)1’-0”(0,30 m)MAX.NNominalPipe Size3⁄4DN201DN251-1⁄4DN321-1⁄2 - 3DN40 - DN80Table S - Two Points of Restraint“M”ANSI InchesDNLess than100 psi(6,9 bar)4’-0”(1,22 m)5’-0”(1,52 m)6’-0”(1,83 m)7’-0”(2,13 m)MMAX.ANY DISTANCETwo-PointVerticalRestraintTWO-POINTRESTRAINT“M”Greater than100 psi(6,9 bar)3’-0”(0,91 m)4’-0”(1,22 m)5’-0”(1,52 m)7’-0”(2,13 m)StructureCPVC PipeFasteners x2Fig. 184CPVCPipe Size3⁄41FIG. 184:Max. HangerSpacing (FT.)51⁄26Approx.Weight/1001717Hanger &RestrainerHanger &RestrainerGuide &RestrainerFIG. 188R:CPVCPipe Size3/4111/411/22Max. HangerSpacing (FT.)5 1/266 1/278Approx.Weight/100 lbs1112131416FIG. 187:CPVCPipe Size3/4111/411/22Max. HangerSpacing (FT.)5 1/266 1/278Approx.Weight/100 lbs56789SECTION CSCALE: 1/4" = 1'-0"9'-0"M. CLO.M. BEDROOM 1LIVINGRETREATPATIO 2BEDROOM 4DININGDCPANTRYKITCHENPATIO 1M. CLO.M. BEDROOM 1LIVINGRETREATPATIO 2M. BATH. 1BEDROOM 4DININGENTRYBATH. 2M. BATH. 2BEDROOM 2PWDR.M. BEDROOM 2LAUNDRY 2BEDROOM 3STORAGEHALLLAUNDRY 11-CAR GARAGE2-CAR GARAGEHALL 20175202020175204'-1"10'-7"3'-11"3'-7"1'-11"1'-7"8'-8" 6"2'-9"2'-9"2'-6"6'-1"11'-5"8'-0"4'-5"5'-9"6" 10'-6"2'-1"9'-2"9'-8"5'-1"6'-2"1'-4"11'-10"11'-10"1'-0"6'-7" 11"4'-6"9"12'-0"8'-0"7'-5"2'-5"7'-6"3'-0"4'-10"6'-10"2'-7"5'-5"5'-8"10'-0"2'-7"3'-6"6"3'-6"6"7'-6"4'-2"2'-1"10'-0"5'-6"8'-9"10'-10"12'-8"1'-8" 11" 6" 6" 6" 6"2'-4"45 SFNO A/SCLST23.5 SFNO A/SCLST11 SFCLST15 SFNO A/SCLST15.5 SFNO A/SCLST13 SFCLST13 SF1222222233314'-1"8'-0"3'-2" 1'-8" 1'-8"2020202035.6 SFNO A/SP1P299101103104105106TORBORP5102P3P4100B46"3'-1"6"3'-10"9"1'-0"6"2'-2" 1'-10"1'-0"1'-0"1'-0"1'-0"6"5'-8"9'-1"5'-2"1'-3"3'-7"4'-9"6'-11"6"CLST10 SFUP1'-0"UP1'-0"UP1'-0"3'-4"2'-0" 6'-2"CALC AREA # 1(2) HEAD CALC3.0 K(14X14) SPACINGCALC AREA # 2(2) HEAD CALC3.0 K(14X14) SPACINGCALC AREA # 3(1) HEAD CALC4.9 K(20X20) SPACING1" FIRE SPRINKLER RISERPROVIDE INTERIOR ACCESSPANEL SEE RISER DETAILSECTION DSCALE: 1/4" = 1'-0"9'-0"8'-0"RETREATHALL1-CAR GARAGEDCPANTRYKITCHENPATIO 1M. CLO.M. BEDROOM 1LIVINGRETREATPATIO 2M. BATH. 1BEDROOM 4DININGENTRYBATH. 2M. BATH. 2BEDROOM 2PWDR.M. BEDROOM 2LAUNDRY 2BEDROOM 3STORAGEHALLLAUNDRY 11-CAR GARAGE2-CAR GARAGEHALL 2017520202017520HEAT ZONE2X5HEAT ZONE2X5HEAT ZONE2X5HEAT ZONE2X5HEAT ZONE2X5 HEAT ZONE2X5HEAT ZONE2X5HEAT ZONE2X5HEAT ZONE2X5HEAT ZONE2X5HEAT ZONE2X5 HEAT ZONE2X5 HEAT ZONE2X5HEAT ZONE2X5HEAT ZONE2X5HEAT ZONE2X5HEAT ZONE2X5HEAT ZONE2X5 1222222233315'-3"10'-0"5'-0"4'-11"12'-0"3'-10"7'-0"2'-11"2'-8"7'-10"6'-0"7'-10"6'-2"7'-4"4'-2" 9'-5"7'-0" 2'-2"7'-0"6'-7" 14'-0"11'-10"5'-0" 2'-1"3'-2"10'-1"5'-8"9'-5"8'-0"2'-11"5'-3" 8'-6"11'-2"3'-8"4'-2"4'-7"8'-2"14'-0"3'-10"2'-2"5'-0"7'-0"8'-0"4'-9"5'-6"10'-7"5'-1"5'-0"4'-0"4'-1"1'-7"2'-11"7'-0"7'-2"3'-7"7'-10"9'-0"8'-10"6'-8"4'-1"6'-7"3'-0"8'-0"8'-0"20202020SPRINKLER LEGEND SYM CNT STYLE (k)NPT MAKE SIN TEMP SPACING NOTES: 18 PEND 3.0 1/2"VIKING VK496 155 14'X14' ECQR FLAT CONCEALED PEND 9 PEND 4.9 1/2"VIKING VK494 155 20'X20'ECQR FLAT CONCEALED PEND 6 PEND 3.0 1/2"VIKING VK496 200 14'X14' ECQR WHITE SEMI RECESSED PEND 2 PEND 4.9 1/2"VIKING VK468 155 16'X16' ECQR WHITE SEMI RECESSED PEND 1 UPRT 5.6 1/2"VIKING VK300 200 150 SF SSQR BRASS UPRIGHT ABOVE FAUPiping Plan/RCP PlanCross Sections18"=1'-0"FP-2.0HYDRAULIC INFORMATIONThis system is protected by a hydraulically DesignedAutomatic Sprinkler SystemLOCATION:Calc Area # 2Total Number ofSprinklers Suppliedby This Riser:36Total Number ofFlowing Sprinklersin this Calc Area:2BASIS OF DESIGN:DesignStandard:NFPA 13DDesignDensity:0.05HazardGroup:ResidentialDesign Area:2 HDK Factor: 3.0Area PerSprinkler:196 SFSYSTEM DEMAND:GPMDemand atBase ofRiser24.1GPM Demandat WaterSupplySource29.1RequiredPSI at Baseof Riser37.7Required PSIat WaterSource43.0Additional PSI SafetyMargin:7.3HOSE STREAM ALLOWANCEDOMESTICGPM ADDED5 GPMGPM OUTSIDEALLOWANCE0REMOTE SPRINKLERFLOW:12 GPM @16 PSIHYDRAULIC INFORMATIONThis system is protected by a hydraulically DesignedAutomatic Sprinkler SystemLOCATION:Calc Area # 3Total Number ofSprinklers Suppliedby This Riser:36Total Number ofFlowing Sprinklersin this Calc Area:1BASIS OF DESIGN:DesignStandard:NFPA 13DDesignDensity:0.05HazardGroup:ResidentialDesign Area:1 HDK Factor:4.9Area PerSprinkler:400 SFSYSTEM DEMAND:GPMDemand atBase ofRiser20.0GPM Demandat WaterSupplySource25.0RequiredPSI at Baseof Riser31.5Required PSIat WaterSource36.0Additional PSI SafetyMargin:15.8HOSE STREAM ALLOWANCEDOMESTICGPM ADDED5 GPMGPM OUTSIDEALLOWANCE0REMOTE SPRINKLERFLOW:20 GPM @16.7 PSI-11/8"=1'-0"1st FLOOR PIPING PLAN -41/8"=1'-0"CROSS SECTION C175-31/8"=1'-0"CROSS SECTION D-21/8"=1'-0"1st FLOOR PIPING RCP PLANP.O.Box 381 Redlands, CA 92373 (760) 340-3602 * Fireprospecialist@yahoo.com FIRE PROTECTION SPECIALISTS Tanner Residence 78668 Calle Tampico, La Quinta, CA 92253 FIRE SPRINKLER SYSTEMSHEET TITLE:SHEET SCALE:SHEET NO:REV DATE DESCRIPTION DB Job No: Plot Date: Date: Design By: 3/25/21ofFPS02 3/25/21HYDRAULIC INFORMATIONThis system is protected by a hydraulically DesignedAutomatic Sprinkler SystemLOCATION:Calc Area # 1Total Number ofSprinklers Suppliedby This Riser:36Total Number ofFlowing Sprinklersin this Calc Area:2BASIS OF DESIGN:DesignStandard:NFPA 13DDesignDensity:0.05HazardGroup:ResidentialDesign Area:2 HDK Factor: 3.0Area PerSprinkler:196 SFSYSTEM DEMAND:GPMDemand atBase ofRiser20.0GPM Demandat WaterSupplySource25.0RequiredPSI at Baseof Riser29.5Required PSIat WaterSource34.0Additional PSI SafetyMargin:17.7HOSE STREAM ALLOWANCEDOMESTICGPM ADDED5 GPMGPM OUTSIDEALLOWANCE0REMOTE SPRINKLERFLOW:10 GPM @11.11 PSI FIRE PROTECTION SPECIALISTS PO BOX 381 CA, 92373 (760) 340-3602 Job Name : TANNER RESIDENCE Drawing : 1 Location : 78668 CALLE TAMPICO‚ LA QUINTA‚ CA 92253 Remote Area : CALC AREA # 1 Contract : N/A Data File : REV#0_Tanner Residence Calc Area # 1 - 3-25-21.WXF Date/Time : 03/26/2021 - 01:03 AM Computer Programs by Hydratec Inc. Revision: 50.5520.727 FIRE PROTECTION SPECIALISTS Page 1 TANNER RESIDENCE Date 03/25/2021 HYDRAULIC DESIGN INFORMATION SHEET Name - TANNER RESIDENCE Date - 03/25/2021 Location - 78668 CALLE TAMPICO‚ LA QUINTA‚ CA 92253 Building - 1 System No. - CALC AREA # 1 Contractor - FPS Contract No. - N/A Calculated By - FPS Drawing No. - FP-2.0 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height 8' OCCUPANCY - R-3 S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( ) S ( )OtherN/A T ( )Specific Ruling N/A Made by N/A Date N/A E M Listed Flow at Start Point - 10 Gpm System Type Listed Pres. at Start Point - 11.11Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 14 x 14 ( ) Deluge ( ) PreAction E Domestic Flow Added - 5 Gpm Sprinkler or Nozzle S Additional Flow Added - N/A Gpm Make VIKING Model VK470 I Elevation at Highest Outlet - 8' Feet Size 1/2" K-Factor 3.0 G Note:N/A Temperature Rating 175 N N/A Calculation Gpm Required 24.957 Psi Required 34.033 At Test Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 11/12/2020 Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 56.08 Elev. R Residual (Psi) - 50 Other Well Flow (Gpm) - 30 Proof Flow Gpm S Elevation - 0 P Location: P L Source of Information: COCHELLA WATER DISTRICT Y JENNIFER QUEIROZ Computer Programs by Hydratec Inc. Revision: 50.5520.727 FIRE PROTECTION SPECIALISTSPage 2 TANNER RESIDENCE Date 03/25/2021 10203040E50R60U70S80S90E100R110P12013014015010 20 30 40 50 60 70 80 90FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C210 Percent UnderC1 - Static Pressure : 56.08 C2 - Residual Pressure: 50 C2 - Residual Flow : 30 D1 - Elevation : 4.981 D2 - System Flow : 19.957 D2 - System Pressure : 34.033 Hose ( Demand ) : 5 D3 - System Demand : 24.957 Safety Margin : 17.722 D1D2D3Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.5520.727 FIRE PROTECTION SPECIALISTSPage 3 TANNER RESIDENCE Date 03/25/2021 Fitting Legend Abbrev.Name ½¾11¼1½22½33½456810121416182024 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow N *CPVC 90'Ell Harvel-Spears 7789111213000000000000 O *CPVC Tee - Branch 33568101215000000000000 R *CPVC Coupling Tee - Run 11111122000000000000 S NFPA 13 Swing Check 0 0 5 7 9 11141619222732455565 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.5520.727 FIRE PROTECTION SPECIALISTS Page 4 TANNER RESIDENCE Date 03/25/2021 SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure TEST 56.08 50 30.0 51.754 24.96 34.033 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes P1 8.0 3 11.0 9.95 0.05 196 P2 8.0 3 11.13 10.01 0.05 196 99 8.5 11.22 100 9.5 13.09 101 9.5 14.74 102 9.5 16.03 103 9.5 18.97 104 9.5 19.21 105 9.5 20.66 106 9.5 20.82 TOR 9.5 21.6 BOR 1.0 29.54 5.0 UG1 -3.0 32.26 TEST -3.5 34.03 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.5520.727 FIRE PROTECTION SPECIALISTS Page 5 TANNER RESIDENCE Date 03/25/2021 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf P1 8 3.00 9.95 1 N 7.0 15.500 150 11.000 to R 1.0 8.000 -0.217 99 8.500 9.95 1.101 23.500 0.0187 0.440 Vel = 3.35 0.0 99 9.95 11.223 K Factor = 2.97 P2 8 3.00 10.01 1 N 7.0 4.500 150 11.128 to O 5.0 12.000 -0.217 99 8.500 10.01 1.101 16.500 0.0189 0.312 Vel = 3.37 99 8.500 9.95 1 2N 14.0 16.000 150 11.223 to 4R 4.0 18.000 -0.433 100 9.500 19.96 1.101 34.000 0.0678 2.304 Vel = 6.73 100 9.500 0.0 1 O 5.0 17.250 150 13.094 to 2R 2.0 7.000 0.0 101 9.500 19.96 1.101 24.250 0.0678 1.644 Vel = 6.73 101 9.500 0.0 1 N 7.0 10.000 150 14.738 to 2R 2.0 9.000 0.0 102 9.500 19.96 1.101 19.000 0.0677 1.287 Vel = 6.73 102 9.500 0.0 1 O 5.0 35.500 150 16.025 to 3R 3.0 8.000 0.0 103 9.500 19.96 1.101 43.500 0.0678 2.948 Vel = 6.73 103 9.500 0.0 1 R 1.0 2.500 150 18.973 to 1.000 0.0 104 9.500 19.96 1.101 3.500 0.0677 0.237 Vel = 6.73 104 9.500 -10.14 1 O 5.0 46.500 150 19.210 to 7R 7.0 33.000 0.0 105 9.500 9.82 1.101 3N 21.0 79.500 0.0183 1.452 Vel = 3.31 105 9.500 0.0 1 R 1.0 7.500 150 20.662 to 1.000 0.0 106 9.500 9.82 1.101 8.500 0.0182 0.155 Vel = 3.31 106 9.500 10.14 1 N 7.0 4.500 150 20.817 to 7.000 0.0 TOR 9.500 19.96 1.101 11.500 0.0677 0.779 Vel = 6.73 TOR 9.500 0.0 1 R 1.0 8.000 150 21.596 to S 9.563 10.562 6.681 * * Fixed Loss = 3 BOR 1 19.96 1.101 Fsp 0.0 18.562 0.0678 1.258 Vel = 6.73 BOR 1 H5 5.00 1.25 Eql 8.706 8.000 140 29.535 to 8.706 1.732 UG1 -3 24.96 1.265 16.706 0.0593 0.990 Vel = 6.37 UG1 -3 0.0 1.25 2N 16.0 32.000 150 32.257 to 16.000 0.217 TEST -3.500 24.96 1.394 48.000 0.0325 1.559 Vel = 5.25 0.0 TEST 24.96 34.033 K Factor = 4.28 104 9.500 10.14 1 2N 14.0 54.000 150 19.210 to 2O 10.0 29.000 0.0 106 9.500 10.14 1.101 5R 5.0 83.000 0.0194 1.607 Vel = 3.42 0.0 106 10.14 20.817 K Factor = 2.22 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.5520.727 FIRE PROTECTION SPECIALISTS Page 6 TANNER RESIDENCE Date 03/25/2021 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.5520.727 FIRE PROTECTION SPECIALISTS PO BOX 381 CA, 92373 (760) 340-3602 Job Name : TANNER RESIDENCE Drawing : 1 Location : 78668 CALLE TAMPICO‚ LA QUINTA‚ CA 92253 Remote Area : CALC AREA # 2 Contract : N/A Data File : REV#0_Tanner Residence Calc Area # 2 - 3-25-21.WXF Date/Time : 03/26/2021 - 01:01 AM Computer Programs by Hydratec Inc. Revision: 50.5520.727 FIRE PROTECTION SPECIALISTS Page 1 TANNER RESIDENCE Date 03/25/2021 HYDRAULIC DESIGN INFORMATION SHEET Name - TANNER RESIDENCE Date - 03/25/2021 Location - 78668 CALLE TAMPICO‚ LA QUINTA‚ CA 92253 Building - 1 System No. - CALC AREA # 2 Contractor - FPS Contract No. - N/A Calculated By - FPS Drawing No. - FP-2.0 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height 9' OCCUPANCY - R-3 S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( ) S ( )OtherN/A T ( )Specific Ruling N/A Made by N/A Date N/A E M Listed Flow at Start Point - 12 Gpm System Type Listed Pres. at Start Point - 16 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 14 x 14 ( ) Deluge ( ) PreAction E Domestic Flow Added - 5 Gpm Sprinkler or Nozzle S Additional Flow Added - N/A Gpm Make VIKING Model VK496 I Elevation at Highest Outlet - 9' Feet Size 1/2" K-Factor 3.0 G Note:N/A Temperature Rating 175 N N/A Calculation Gpm Required 39.108 Psi Required 42.994 At Test Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 11/12/2020 Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 56.08 Elev. R Residual (Psi) - 50 Other Well Flow (Gpm) - 30 Proof Flow Gpm S Elevation - 0 P Location: P L Source of Information: COCHELLA WATER DISTRICT Y JENNIFER QUEIROZ Computer Programs by Hydratec Inc. Revision: 50.5520.727 FIRE PROTECTION SPECIALISTSPage 2 TANNER RESIDENCE Date 03/25/2021 10203040E50R60U70S80S90E100R110P12013014015010 20 30 40 50 60 70 80 90FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C210 Percent UnderC1 - Static Pressure : 56.08 C2 - Residual Pressure: 50 C2 - Residual Flow : 30 D1 - Elevation : 5.414 D2 - System Flow : 24.108 D2 - System Pressure : 42.994 Hose ( Demand ) : 5 D3 - System Demand : 29.108 Safety Margin : 7.336 D1D2D3Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.5520.727 FIRE PROTECTION SPECIALISTSPage 3 TANNER RESIDENCE Date 03/25/2021 Fitting Legend Abbrev.Name ½¾11¼1½22½33½456810121416182024 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow N *CPVC 90'Ell Harvel-Spears 7789111213000000000000 O *CPVC Tee - Branch 33568101215000000000000 R *CPVC Coupling Tee - Run 11111122000000000000 S NFPA 13 Swing Check 0 0 5 7 9 11141619222732455565 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.5520.727 FIRE PROTECTION SPECIALISTS Page 4 TANNER RESIDENCE Date 03/25/2021 SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure TEST 56.08 50 30.0 50.33 29.11 42.994 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes P3 9.0 3 16.0 12.0 0.05 196 P4 9.0 3 16.29 12.11 0.05 196 B4 9.5 16.22 99 9.5 17.13 100 9.5 17.13 101 9.5 19.46 102 9.5 21.29 103 9.5 25.47 104 9.5 25.81 105 9.5 27.87 106 9.5 28.09 TOR 9.5 29.19 BOR 1.0 37.66 5.0 UG1 -3.0 40.71 TEST -3.5 42.99 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.5520.727 FIRE PROTECTION SPECIALISTS Page 5 TANNER RESIDENCE Date 03/25/2021 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf P3 9 3.00 12.00 1 N 7.0 8.500 150 16.000 to R 1.0 8.000 -0.217 B4 9.500 12.0 1.101 16.500 0.0265 0.437 Vel = 4.04 0.0 B4 12.00 16.220 K Factor = 2.98 P4 9 3.00 12.11 1 O 5.0 0.500 150 16.288 to 5.000 -0.217 B4 9.500 12.11 1.101 5.500 0.0271 0.149 Vel = 4.08 B4 9.500 12.00 1 O 5.0 4.500 150 16.220 to 5.000 0.0 100 9.500 24.11 1.101 9.500 0.0961 0.913 Vel = 8.12 0.0 100 24.11 17.133 K Factor = 5.82 99 9.500 0.0 1 2N 14.0 16.000 150 17.133 to 4R 4.0 18.000 0.0 100 9.500 0.0 1.101 34.000 0 0.0 Vel = 0 100 9.500 24.11 1 O 5.0 17.250 150 17.133 to 2R 2.0 7.000 0.0 101 9.500 24.11 1.101 24.250 0.0961 2.331 Vel = 8.12 101 9.500 0.0 1 N 7.0 10.000 150 19.464 to 2R 2.0 9.000 0.0 102 9.500 24.11 1.101 19.000 0.0962 1.827 Vel = 8.12 102 9.500 0.0 1 O 5.0 35.500 150 21.291 to 3R 3.0 8.000 0.0 103 9.500 24.11 1.101 43.500 0.0961 4.181 Vel = 8.12 103 9.500 0.0 1 R 1.0 2.500 150 25.472 to 1.000 0.0 104 9.500 24.11 1.101 3.500 0.0963 0.337 Vel = 8.12 104 9.500 -12.25 1 O 5.0 46.500 150 25.809 to 7R 7.0 33.000 0.0 105 9.500 11.86 1.101 3N 21.0 79.500 0.0259 2.058 Vel = 4.00 105 9.500 0.0 1 R 1.0 7.500 150 27.867 to 1.000 0.0 106 9.500 11.86 1.101 8.500 0.0259 0.220 Vel = 4.00 106 9.500 12.25 1 N 7.0 4.500 150 28.087 to 7.000 0.0 TOR 9.500 24.11 1.101 11.500 0.0961 1.105 Vel = 8.12 TOR 9.500 0.0 1 R 1.0 8.000 150 29.192 to S 9.563 10.562 6.681 * * Fixed Loss = 3 BOR 1 24.11 1.101 Fsp 0.0 18.562 0.0962 1.785 Vel = 8.12 BOR 1 H5 5.00 1.25 Eql 8.706 8.000 140 37.658 to 8.706 1.732 UG1 -3 29.11 1.265 16.706 0.0788 1.316 Vel = 7.43 UG1 -3 0.0 1.25 2N 16.0 32.000 150 40.706 to 16.000 0.217 TEST -3.500 29.11 1.394 48.000 0.0431 2.071 Vel = 6.12 0.0 TEST 29.11 42.994 K Factor = 4.44 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.5520.727 FIRE PROTECTION SPECIALISTS Page 6 TANNER RESIDENCE Date 03/25/2021 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 104 9.500 12.24 1 2N 14.0 54.000 150 25.809 to 2O 10.0 29.000 0.0 106 9.500 12.24 1.101 5R 5.0 83.000 0.0274 2.278 Vel = 4.12 0.0 106 12.24 28.087 K Factor = 2.31 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.5520.727 FIRE PROTECTION SPECIALISTS PO BOX 381 CA, 92373 (760) 340-3602 Job Name : TANNER RESIDENCE Drawing : 1 Location : 78668 CALLE TAMPICO‚ LA QUINTA‚ CA 92253 Remote Area : CALC AREA # 3 Contract : N/A Data File : REV#0_Tanner Residence Calc Area # 3 - 3-25-21.WXF Date/Time : 03/26/2021 - 01:06 AM Computer Programs by Hydratec Inc. Revision: 50.5520.727 FIRE PROTECTION SPECIALISTS Page 1 TANNER RESIDENCE Date 03/25/2021 HYDRAULIC DESIGN INFORMATION SHEET Name - TANNER RESIDENCE Date - 03/25/2021 Location - 78668 CALLE TAMPICO‚ LA QUINTA‚ CA 92253 Building - 1 System No. - CALC AREA # 3 Contractor - FPS Contract No. - N/A Calculated By - FPS Drawing No. - FP-2.0 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height 9' OCCUPANCY - R-3 S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: (X)1 ( )2 ( )4 ( ) S ( )OtherN/A T ( )Specific Ruling N/A Made by N/A Date N/A E M Listed Flow at Start Point - 20 Gpm System Type Listed Pres. at Start Point - 16.7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 20 x 20 ( ) Deluge ( ) PreAction E Domestic Flow Added - 5 Gpm Sprinkler or Nozzle S Additional Flow Added - N/A Gpm Make VIKING Model VK494 I Elevation at Highest Outlet - 9' Feet Size 1/2" K-Factor 3.0 G Note:N/A Temperature Rating 155 N N/A Calculation Gpm Required 25.024 Psi Required 35.978 At Test Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 11/12/2020 Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 56.08 Elev. R Residual (Psi) - 50 Other Well Flow (Gpm) - 30 Proof Flow Gpm S Elevation - 0 P Location: P L Source of Information: COCHELLA WATER DISTRICT Y JENNIFER QUEIROZ Computer Programs by Hydratec Inc. Revision: 50.5520.727 FIRE PROTECTION SPECIALISTSPage 2 TANNER RESIDENCE Date 03/25/2021 10203040E50R60U70S80S90E100R110P12013014015010 20 30 40 50 60 70 80 90FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C210 Percent UnderC1 - Static Pressure : 56.08 C2 - Residual Pressure: 50 C2 - Residual Flow : 30 D1 - Elevation : 5.414 D2 - System Flow : 20.024 D2 - System Pressure : 35.978 Hose ( Demand ) : 5 D3 - System Demand : 25.024 Safety Margin : 15.755 D1D2D3Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.5520.727 FIRE PROTECTION SPECIALISTSPage 3 TANNER RESIDENCE Date 03/25/2021 Fitting Legend Abbrev.Name ½¾11¼1½22½33½456810121416182024 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow N *CPVC 90'Ell Harvel-Spears 7789111213000000000000 O *CPVC Tee - Branch 33568101215000000000000 R *CPVC Coupling Tee - Run 11111122000000000000 S NFPA 13 Swing Check 0 0 5 7 9 11141619222732455565 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.5520.727 FIRE PROTECTION SPECIALISTS Page 4 TANNER RESIDENCE Date 03/25/2021 SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure TEST 56.08 50 30.0 51.733 25.02 35.978 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes P5 9.0 4.9 16.7 20.02 0.05 400 102 9.5 17.92 103 9.5 20.88 104 9.5 21.12 105 9.5 22.58 106 9.5 22.74 TOR 9.5 23.52 BOR 1.0 31.47 5.0 UG1 -3.0 34.19 TEST -3.5 35.98 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.5520.727 FIRE PROTECTION SPECIALISTS Page 5 TANNER RESIDENCE Date 03/25/2021 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf P5 9 4.90 20.02 1 2N 14.0 6.000 150 16.700 to R 1.0 15.000 -0.217 102 9.500 20.02 1.101 21.000 0.0682 1.433 Vel = 6.75 102 9.500 0.0 1 O 5.0 35.500 150 17.916 to 3R 3.0 8.000 0.0 103 9.500 20.02 1.101 43.500 0.0682 2.966 Vel = 6.75 103 9.500 0.0 1 R 1.0 2.500 150 20.882 to 1.000 0.0 104 9.500 20.02 1.101 3.500 0.0680 0.238 Vel = 6.75 104 9.500 -10.17 1 O 5.0 46.500 150 21.120 to 7R 7.0 33.000 0.0 105 9.500 9.85 1.101 3N 21.0 79.500 0.0184 1.461 Vel = 3.32 105 9.500 0.0 1 R 1.0 7.500 150 22.581 to 1.000 0.0 106 9.500 9.85 1.101 8.500 0.0184 0.156 Vel = 3.32 106 9.500 10.17 1 N 7.0 4.500 150 22.737 to 7.000 0.0 TOR 9.500 20.02 1.101 11.500 0.0682 0.784 Vel = 6.75 TOR 9.500 0.0 1 R 1.0 8.000 150 23.521 to S 9.563 10.562 6.681 * * Fixed Loss = 3 BOR 1 20.02 1.101 Fsp 0.0 18.562 0.0682 1.266 Vel = 6.75 BOR 1 H5 5.00 1.25 Eql 8.706 8.000 140 31.468 to 8.706 1.732 UG1 -3 25.02 1.265 16.706 0.0596 0.995 Vel = 6.39 UG1 -3 0.0 1.25 2N 16.0 32.000 150 34.195 to 16.000 0.217 TEST -3.500 25.02 1.394 48.000 0.0326 1.566 Vel = 5.26 0.0 TEST 25.02 35.978 K Factor = 4.17 104 9.500 10.17 1 2N 14.0 54.000 150 21.120 to 2O 10.0 29.000 0.0 106 9.500 10.17 1.101 5R 5.0 83.000 0.0195 1.617 Vel = 3.43 0.0 106 10.17 22.737 K Factor = 2.13 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.5520.727 FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 1 of 6 Form No. F_012116 20.06.26 Rev 20.2 1. DESCRIPTION Viking Freedom® Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-factor of 4.9 (70.6 metric*), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile small-diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “push-on” and “thread-on” designs of the concealed cover plate assemblies allow easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2” (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS cULusEU Listed: Category VKKW Refer to the Approval Charts and Design Criteria for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATASpecifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2” (15 mm) NPT Nominal K-factor: 4.9 U.S. (70.6 metric*) Glass-bulb fluid temperature rating: to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: Phosphor Bronze UNS-C51000 Belleville Spring Sealing Assembly: Beryllium Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: High Density Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 or Stainless Steel UNS-S30400 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: The sprinkler and cover plate must be ordered separately. Refer to Tables 1 and 2. 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches the cover plate’s nominal temperature rating, the cover plate detaches and releases the deflector. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand. When the temperature reaches the sprinkler’s nominal temperature rating, the glass bulb shatters releasing the yoke, pip cap assembly and sealing spring. Water begins flowing through the sprinkler orifice and strikes the deflector form- ing a uniform spray pattern over a specific area of coverage, which is determined by the water supply pressure at the sprinkler, in order to extinguish or control the fire. Replaces Form No. F_012116 Rev 20.1 (Added cover plate options.) FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 2 of 6 Form No. F_012116 20.06.26 Rev 20.2 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: SPRINKLER ORDERING INFORMATION Instructions: (1) Select a Sprinkler Base Part Number (2) Add the suffix for the desired Finish (3) Add the suffix for the desired Sprinkler Temperature Rating (4) Order a cover plate (refer to Table 2) Example: 20759AE = 200 °F (93 °C) Temperature Rated Sprinkler with a standard Brass finish. Sprinkler Base Part Number1 Size 1: Finishes 2: Temperature Ratings7 NPT Inch Description Suffix Nominal Rating Bulb Color Max. Ambient Ceiling Temperature2 Suffix 20759 1/2 Brass A 155 °F (68 °C)Red 100 °F (38 °C)B ENT5,6 JN 200 °F (93 °C)Green 150 °F (65 °C)E Corrosion Resistant Sprinkler Finish: ENT Accessories Sprinkler Wrenches and tools: A. Heavy Duty Part Number: 14047W/B3 (available since 2006) B. Head Cabinet Wrench Part Number: 140313,4 (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part Number: 144128 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 148678 (available since 2007) Sprinkler Cabinet: Holds up to 6 sprinklers: Part number 01731A (available since 1971). Footnotes 1. Part number shown is the base part number. For complete part number, refer to the current Viking price list schedule. 2. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. Requires a ½” ratchet (not available from Viking). 4. Also optional for removal of the protective cap. Ideal for sprinkler cabinets. 5. cULus Listed as corrosion resistant. 6. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. 7. The sprinkler temperature rating is stamped on the deflector. 8. The installer tool is for push-on style cover plates only. FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 3 of 6 Form No. F_012116 20.06.26 Rev 20.2 TABLE 2: COVER PLATE ORDERING INFORMATION Instructions: (1) Select a Cover Plate Base Part Number (2) Add the suffix for the desired Finish (3) Add the suffix for the required Cover Plate Nominal Rating. Example: 23190MC/W = 165 °F (74 °C) Temperature Rated, 2-3/4” (70 mm) diameter, Thread-On style, Round Cover Plate with a Painted White finish. 1: Select a Cover Plate Base Part Number3 2: Select a FinishThread-On Style Push-On Style Base Part Number1 Size Inch (mm)Type Base Part Number Size Inch (mm)Type Description Suffix5 23190 2-3/4 (70)Round 23447 2-3/4 (70)Round Polished Chrome F 23174 3-5/16 (84)Round 23463 3-5/16 (84)Round Brushed Chrome F-/B 23179 3-5/16 (84)Square 23482 3-5/16 (84)Square Bright Brass B 231935 2-3/4 (70)Stainless Steel Round 234555 2-3/4 (70)Stainless Steel Round Antique Brass B-/A Brushed Brass B-/B 231835 3-5/16 (84)Stainless Steel Round 234735 3-5/16 (84)Stainless Steel Round Brushed Copper E-/B Painted White M-/W Painted Ivory M-/I Painted Black M-/B 3: Temperature Rating Matrix1,2 Cover Plate Nominal Rating (Required) Temperature Classification Sprinkler Nominal Rating Sprinkler Maximum Ambient Ceiling Temperature2 Suffix 135 °F (57 °C)Ordinary 155 °F (68 °C)100 °F (38 °C)A 165 °F (74 °C)Intermediate 200 °F (93 °C)150 °F (65 °C)C Footnotes 1. Part number shown is the base part number. For complete part number, refer to the current Viking price list schedule. 2. The sprinkler temperature rating is stamped on the deflector. 3. Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 4. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. 5. Stainless Steel versions are not available with any finishes or paint. FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 4 of 6 Form No. F_012116 20.06.26 Rev 20.2 Approval ChartViking VK494, 4.9 K-factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the Design Criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D S p r i n k l e r B a s e Part Number 1 SIN NPT Thread Size Nominal K-factor Maximum Water Working PressureInchesmmU.S.metric 2 20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar) Max. Coverage Area 6 W X L Ft. X Ft. (m X m) Flow GPM (LPM) Pressure PSI (bar)Deflector to Ceiling Installation Type Listings and Approvals3,5 Minimum Spacing Ft. (m)155 °F (68 °C), 200 °F (93 °C) Temperature Rated Sprinklers 4 12 X 12 (3.7 X 3.7) 13 (49.2) 7.0 (0.48) Refer to Figure 2 Concealed with Cover Plate Assembly. See Footnote 7. See Footnotes 8, & 9 8 (2.4) 14 X 14 (4.3 X 4.3) 13 (49.2) 7.0 (0.48) 16 X 16 (4.9 X 4.9) 13 (49.2) 7.0 (0.48) 18 X 18 (5.5 X 5.5) 17 (64.4) 12.0 (0.83) 20 X 20 (6.1 X 6.1) 20 (75.7) 16.7 (1.15) Footnotes 1. Part number shown is the base part number. For complete part number, refer to the current Viking price schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 4. Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. 5. Meets New York City requirements, effective July 1, 2008. 6. For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum “Flow” and “Pressure” used. 7. Other paint colors are available on request with the same listings as the standard finish colors. Stainless Steel cover plates are not available with any finishes or paint. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 8. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 7. 9. C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 5 of 6 Form No. F_012116 20.06.26 Rev 20.2 DESIGN CRITERIA (Also refer to the Approval Chart.) UL Listing Requirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 9.5.2.1 or 10.2.4.1.2 of the current edition of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be in-stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins Sprinkler Wrench Part No. 14047W/B** ** A 1/2” ratchet is required (Not available from Viking) 2-1/4” (57 mm) diameter opening required in the ceiling. Step 2: Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Figure 1: Sprinkler Installation and Proper Wrench Usage NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Sprinkler wrench flat Sprinkler frame arms FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 6 of 6 Form No. F_012116 20.06.26 Rev 20.2 Figure 2: Sprinkler Dimensions and Cover Installation 1/2” (15 mm) NPT 2-1/4”(57 mm)2-9/16” (65 mm)Maximum 2-1/16” (52 mm)Minimum 2-3/4” (70 mm) or 3-5/16” (84 mm)NOTE: Upon sprinkler activation, the deflector descends to approximately 13/16” (21 mm) below the sprinkler body. Figure 3: Identification of Custom Paint for Concealed Covers All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 4: Square Cover Assembly 3-5/16” (84 mm)FACTORY APPLIE D C USTO M P AI NT COLORReplaces Form No. F_012116 Rev 20.1 (Added cover plate options.) FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 1 of 5 Form No. F_032218 20.06.26 Rev 20.2 1. DESCRIPTION Viking Freedom® Residential Concealed Pendent Sprinkler VK496 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 3.0 (43.2 metric*), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre-assembled with a threaded adapter for installation with a low- profile small-diameter cover assembly installed flush to the ceiling. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “The “push-on” and “thread-on” designs of the concealed cover plate assemblies allow easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2” (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL- US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS UL Listed (C-UL-US-EU): Category VKKW Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATASpecifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 3.0 U.S. (43.2 metric*) Glass-bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C31600 Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-C51000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: PolyethyleneCover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: The sprinkler and cover plate must be ordered separately. Refer to Tables 1 and 2. 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Replaces Form No. F_032218 Rev 20.1 (Added cover plate options.) FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 2 of 5 Form No. F_032218 20.06.26 Rev 20.2 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pressure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK496 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: SPRINKLER ORDERING INFORMATION Instructions: (1) Select a Sprinkler Base Part Number (2) Add the suffix for the desired Finish (3) Add the suffix for the desired Sprinkler Temperature Rating (4) Order a cover plate (refer to Table 2) Example: 22773AE = 200 °F (93 °C) Temperature Rated Sprinkler with a standard Brass finish. Sprinkler Base Part Number1 Size 1: Finishes 2: Temperature Ratings7 NPT Inch Description Suffix Nominal Rating Bulb Color Max. Ambient Ceiling Temperature2 Suffix 22773 1/2 Brass A 155 °F (68 °C)Red 100 °F (38 °C)B ENT5,6 JN 200 °F (93 °C)Green 150 °F (65 °C)E Corrosion Resistant Sprinkler Finish: ENT Accessories Sprinkler Wrenches and tools: A. Heavy Duty Part Number: 14047W/B3 (available since 2006) B. Head Cabinet Wrench Part Number: 140313,4 (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part Number: 144128 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 148678 (available since 2007) Sprinkler Cabinet: Holds up to 6 sprinklers: Part number 01731A (available since 1971). Footnotes 1. Part number shown is the base part number. For complete part number, refer to the current Viking price list schedule. 2. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. Requires a ½” ratchet (not available from Viking). 4. Also optional for removal of the protective cap. Ideal for sprinkler cabinets. 5. cULus Listed as corrosion resistant. 6. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. 7. The sprinkler temperature rating is stamped on the deflector. 8. The installer tool is for push-on style cover plates only. FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 3 of 5 Form No. F_032218 20.06.26 Rev 20.2 TABLE 2: COVER PLATE ORDERING INFORMATION Instructions: (1) Select a Cover Plate Base Part Number (2) Add the suffix for the desired Finish (3) Add the suffix for the required Cover Plate Nominal Rating. Example: 23190MC/W = 165 °F (74 °C) Temperature Rated, 2-3/4” (70 mm) diameter, Thread-On style, Round Cover Plate with a Painted White finish. 1: Select a Cover Plate Base Part Number3 2: Select a FinishThread-On Style Push-On Style Base Part Number4 Size Inch (mm)Type Base Part Number Size Inch (mm)Type Description Suffix5 23190 2-3/4 (70)Round 23447 2-3/4 (70)Round Polished Chrome F 23174 3-5/16 (84)Round 23463 3-5/16 (84)Round Brushed Chrome F-/B 23179 3-5/16 (84)Square 23482 3-5/16 (84)Square Bright Brass B Antique Brass B-/A Brushed Brass B-/B Brushed Copper E-/B Painted White M-/W Painted Ivory M-/I Painted Black M-/B 3: Temperature Rating Matrix1,2 Cover Plate Nominal Rating (Required) Temperature Classification Sprinkler Nominal Rating Sprinkler Maximum Ambient Ceiling Temperature2 Suffix 135 °F (57 °C)Ordinary 155 °F (68 °C)100 °F (38 °C)A 165 °F (74 °C)3 Intermediate 200 °F (93 °C)150 °F (65 °C)C Footnotes 1. The sprinkler temperature rating is stamped on the deflector. 2. Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. Maximum ambient temperature for cover assembly is 100 °F (38 °C). 4. Part number shown is the base part number. For complete part number, refer to current our price list schedule. 5. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 4 of 5 Form No. F_032218 20.06.26 Rev 20.2 APPROVAL CHART VK496, 3.0 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D S p r i n k l e r B a s e Part Number 1 SIN Thread Size Nominal K-Factor Maximum Water Working PressureInchesmmU.S.metric 2 22773 VK496 1/2 15 3.0 43.2 175 psi (12 bar) Maximum Coverage Area 5 W X L Ft. X Ft. (m X m) All Temperatures Deflector to Ceiling Installation Type Listings and Approvals3 Minimum Spacing Ft. (m)Flow gpm (Lpm) Pressure PSI (bar) 4 12 X 12 (3.7 X 3.7) 8 (30.3) 7.1 (0.49) Refer to Figure 2 Concealed with Cover Plate Assembly. See Footnotes 6 & 7. See Footnotes 3, 4, and 8 8 (2.4) 14 X 14 (4.3 X 4.3) 12 (45.4) 16 (1.1) 16 X 16 (4.9 X 4.9) 15 (56.8) 25 (1.72) Footnotes 1. Part number shown is the base part number. For complete part number, refer to current our price schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approv- als. Refer also to Design Criteria. 4. Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. 5. For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum “Flow” and “Pressure” used. 6. Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 7. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 6. 8. C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 5 of 5 Form No. F_032218 20.06.26 Rev 20.2 DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) UL Listing Requirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK496 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be in-stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins Sprinkler Wrench Part No. 14047W/B** ** A 1/2” ratchet is required (Not available from Viking) 2-1/4” (57 mm) diameter opening required in the ceiling. Step 2: Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Figure 1: Sprinkler Installation and Proper Wrench Usage NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Sprinkler wrench flat Sprinkler frame arms FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 6 of 5 Form No. F_032218 20.06.26 Rev 20.2 Figure 2: Sprinkler Dimensions and Cover Installation 1/2” (15 mm) NPT 2-1/4”(58 mm)2-9/16” (65 mm)Maximum 2-1/16” (52 mm)Minimum 2-3/4” (70 mm) or 3-5/16” (84 mm)NOTE: Upon sprinkler activation, the deflector descends to approximately 13/16” (21 mm) below the sprinkler body. Figure 3: Identification of Custom Paint for Concealed Covers All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 4: Square Cover Assembly 3-5/16” (84 mm) Replaces Form No. F_032218 Rev 20.1 (Added cover plate options.) FACTORY APPLIE D C USTO M P AI NT COLOR TECHNICAL DATA FREEDOM® RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) Form No. F_061011 19.02.21 Rev 19.1 Page 1 of 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION Viking Freedom® Residential Pendent Sprinkler VK470 is a thermosensitive, glass-bulb residential sprinkler available in several different finishes and temperature ratings to meet varying design requirements. The Electroless Nickel PTFE (ENT) coating has been inves- tigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Chart. The sprinkler orifice design, with a K-Factor of 3.0 (43.2 metric*), allows efficient use of available water supplies for the hydraulically designed fire-protection system. The glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. 2. LISTINGS AND APPROVALS UL Listed (C-UL-US-EU): Category VKKW Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing require- ments that must be followed. 3. TECHNICAL DATA Specifications: Avaiilable since 2012. Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 3.0 U.S. (43.2 metric*) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4” (58 mm) Covered by the following U.S. Patent: 9,265,981 Material Standards: Frame Casting: QM Brass Deflector: Phosphor Bronze UNS-C51000 or Brass UNS-C23000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For ENT coated sprinklers: Belleville spring - Exposed, Screw and Pipcap - ENT plated. Available Finishes and Temperature Ratings: Finish Brass Chrome White Polyester Black Polyester ENT Suffix A F M-/W M-/B JN Temperature 155 °F (68 °C)175 °F (79 °C)------ Suffix B D ------ Ordering Information: (Refer to Table 1 and the current Viking price list.) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. Replaces Form No. F_061011 Rev 17.2.P65 (Removed F-1 Escutcheon; Revised images and formatting.) TECHNICAL DATA FREEDOM® RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) Form No. F_061011 19.02.21 Rev 19.1 Page 2 of 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 7. AVAILABILITY The Viking Model VK470 Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: ORDERING INFORMATION Instructions: Using the sprinkler base part number, (1) add the suffix for the desired Finish (2) add the suffix for the desired Temperature Rating. Sprinkler Base Part No. Size 1: Finishes 2: Temperature Ratings NPT Inch BSP mm Description Suffix1 Nominal Rating Bulb Color Max. Ambient Ceiling Temperature3 Suffix 17147 1/2 --Brass A 155 °F (68 °C)Red 100 °F (38 °C)B Chrome F 175 °F (79 °C)Yellow 150 °F (65 °C)D White Polyester 4,5 M-/W Black Polyester 4,5 M-/B ENT 4,5 JN Example: 17147AB = VK470 with Brass Finish and 155 °F (68 °C) Nominal temperature rating. This sprinkler is to be installed into an area with a maximum ambient temperature of 100 °F (38 °C) meaning if the area will experience temperatures above the maximum ambient rating, you shall use a higher temperature-rated sprinkler. Accessories Sprinkler Wrenches (see Figure 1): A. Standard Wrench: Part No. 21475M/B (available since 2017). B. Recessed Socket Wrench: Part No. 13577W/B2 (available since 2006). C. Protective Sprinkler Cap/Escutcheon installation tool7 15915 (available since 2010). Sprinkler Cabinet: A. Up to 6 sprinklers: Part number 01724A (available since 1971). B. 6-12 Sprinklers: Part number 01725A (available since 1971). Footnotes 1. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. 2. Requires a 1/2” ratchet which is not available from Viking. 3. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 4. UL Listed as corrosion resistant. 5. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. 6. Allows installation from the floor by attaching a length of 1” diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. TECHNICAL DATA FREEDOM® RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) Form No. F_061011 19.02.21 Rev 19.1 Page 3 of 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval ChartViking VK470, 3.0 K-Factor Residential Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to the current editions of NFPA 13, 13R or 13D Sprinkler Base Part Number 1 SIN NPT Thread Size Nominal K-Factor Maximum Water Working Pressure Overall Length Inches mm U.S.metric 2 Inches mm 17147 VK470 1/2 15 3.0 43.2 175 psi (12 bar)2-1/4 58 Max. Coverage Area 4 Ft.X Ft. (m X m) Ordinary Temp Rating (155 °F/68 °C) Intermediate Temp Rating (175 °F/79 °C)Deflector to Ceiling Installation Type Listings and Approvals 3 Minimum Spacing Ft. (m)Flow 4 GPM (L/min) Pressure 4 PSI (bar) Flow 4 GPM (L/min) Pressure 4 PSI (bar) 5 NYC NSF 12 X 12 (3.7 X 3.7) 8 (30.3) 7.11 (0.49) 8 (30.3) 7.11 (0.49) 1-1/8 to 2 inch Standard surface- mounted es- cutcheons, or recessed with the Micromatic® Model E-1, E- 2, or E-3 Recessed Escutcheon See Footnotes 6 and 9 See Foot- note 7 --8 (2.4) 14 X 14 (4.3 X 4.3) 10 (37.9) 11.11 (0.77) 10 (37.9) 11.11 (0.77) 15 X 15 (4.6 X 4.6) 12 (45.4) 16 (1.10) 12 (45.4) 16 (1.10) 16 X 16 (4.9 X 4.9) 13 (49.2) 18.8 (1.29) 13 (49.2) 18.8 (1.29) Footnotes 1 Part number shown is the base part number. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K- factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 4 For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. 5 Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. 6 Approved Finishes are: Brass, Chrome, White Polyester, and Black Polyester 8. 7 Meets New York City requirements, effective July 1, 2008. 8 Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors. 9 Approved finish is Electroless Nickel PTFE (ENT). ENT is C-UL-US-EU Listed as corrosion resistant. ENT is available with standard surface-mounted escutcheons or the Micromatic Model E-1 Recessed Escutcheon. TECHNICAL DATA FREEDOM® RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) Form No. F_061011 19.02.21 Rev 19.1 Page 4 of 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA (Also refer to the Approval Chart.) UL Listing Requirements (C-UL-US-EU): When using Viking Residential Pendent Sprinkler VK470 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The mini- mum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No.s F_080190, F_080814, and F_080415 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Figure 2: Installing Recessed Pendent Sprinklers Figure 1: Sprinkler Wrenches Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flatsSprinkler wrench 13655W/B** for recessed pendent sprinklers A B ** A 1/2” ratchet is required (not available from Viking) TECHNICAL DATA FREEDOM® RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) Form No. F_061011 19.02.21 Rev 19.1 Page 5 of 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons 1-3/4” (45 mm)Max. 2-1/8” (54 mm) 1-1/8” (29 mm)Min. 2” (51 mm)Max. 1-1/8” (29 mm)Min. 2-1/8” (54 mm) Ceiling Opening Size: 2-5/16” (59 mm) minimum 2-1/2” (64 mm) maximum Installed with a Model E-1 Recessed Escutcheon Installed with a Model E-2 Thread-on Recessed Escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon 1/2” (15 mm) NPT 2-1/4” (57 mm)1-3/4” (45 mm) Installed with a standard 1/8” surface-mounted escutcheon Ceiling Opening Size: 2-5/16” (59 mm) minimum 2-1/2” (64 mm) maximum Replaces Form No. F_061011 Rev 17.2.P65 (Removed F-1 Escutcheon; Revised images and formatting.) MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) TECHNICAL DATA Page 1 of 4 Form No. F_052114 19.10.14 Rev 19.1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION The Viking Microfast® Quick Response Upright Sprinkler VK300 is a small, thermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2002 and 2020 Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. 3. TECHNICAL DATASpecifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2” NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/16” (56 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT platedOrdering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix (°F/°C): 135°/57° = A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2” NPT thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrench: Standard Wrench: Part No. 21475M/B (available since 2017) Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Replaces Form No. F_052114 Rev 17.1.P65 (Added ENT; updated FM language.) MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) TECHNICAL DATA Page 2 of 4 Form No. F_052114 19.10.14 Rev 19.1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast® Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 135 °F (57 °C)100 °F (38 °C)Orange Ordinary 155 °F (68 °C)100 °F (38 °C)Red Intermediate 175 °F (79 °C)150 °F (65 °C)Yellow Intermediate 200 °F (93 °C)150 °F (65 °C)Green High 286 °F (141 °C)225 °F (107 °C)Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. Figure 1: Standard Sprinkler Wrench 21475M/B Protective Sprinkler Cap Wrench Flat MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) TECHNICAL DATA Page 3 of 4 Form No. F_052114 19.10.14 Rev 19.1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 1 (UL) Microfast® Quick Response Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Number1 SIN Thread Size Nominal K-Factor Overall Length Listings and Approvals3 NPT BSP U.S.metric2 Inches mm cULus VdS LPCB NYC8 12978 VK300 1/2”15 mm 5.6 80.6 2-3/16 56 A1, B2 ----See footnote 7.-- NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 06661B VK300 1/2”15 mm 5.6 80.6 2-3/16 56 A1, B2 ----See footnote 7.-- Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Approved Finishes 1 - Brass, Chrome, White Polyester5,6, and Black Polyester5,6 2 - ENT6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada 5 Other colors are available on request with the same Listings and Approvals as the standard colors. 6 cULus Listed as corrosion resistant. 7 Meets New York City requirements, effective July 1, 2008 8 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA and City of New York Department of Buildings, MEA 89-92-E, Vol. 16. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast® Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) TECHNICAL DATA Page 4 of 4 Form No. F_052114 19.10.14 Rev 19.1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: The Microfast® Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Approval Chart 2 (FM) Microfast® Quick Response Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Number1 SIN Thread Size Nominal K-Factor Overall Length FM Approvals3 (Refer also to Design Criteria below.)NPT BSP U.S.metric2 Inches mm 12978 VK300 1/2”15 mm 5.6 80.6 2-3/16 56 A1, B2 NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 06661B VK300 1/2”15 mm 5.6 80.6 2-3/16 56 A1, B2 Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Approved Finishes 1 - Brass, Chrome, White Polyester5, and Black Polyester5 2 - ENT6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. 5 Other colors are available on request with the same Approvals as the standard colors. 6 FM approved as corrosion resistant. Replaces Form No. F_052114 Rev 17.1.P65 (Added ENT; updated FM language.) OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org April 8, 2021 Fire Protection Specialists PO Box 381 Redlands, CA 92373 Re: Residential Fire Sprinkler Plan Review – TANNER RESIDENCE FSS2021-0051 / 78668 CALLE TAMPICO, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 78668 CALLE TAMPICO PERMIT#: FSS2021-0051 DATE ISSUED: 4/8/2021 DESCRIPTION: TANNER RESIDENCE CONTRACTOR: FIRE PROTECTION SPECIALISTS HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.