Loading...
FSS2021-0085ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT simon chavero 82417 priscilla ct indio CA 92201 (760)574-6512 simon@silveradofire.c om BILL TO simon chavero 82417 priscilla ct indio CA 92201 (760)574-6512 info@silveradofire.com CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE JULIA AGGREH 4/13/2022 4/14/2022 CONTRACTOR REQUESTED FINAL INSPECTION. PERMIT EXPIRED AS OF 1/10/22 (6 MOS FROM DATE OF LAST APPROVED INSPECTION). ADDED EXTENSION FEE OF $83 AND EXTENDED PERMIT TO 4/15/2022 SO CONTRACTOR CAN PAY FEE VIA ETRAKIT. WILL ALSO REQUIRE AN EXTENSION REQUEST LETTER FROM CONTRACTOR. OK TO EXTEND PER KOHL. CONDITIONS Description: ROVNER / FIRE SPRINKLERS / BRES2019-0121 Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 4/22/2021 EPRS Parcel No: 777190004 Site Address: 53497 VIA PISA LA QUINTA,CA 92253 Approved: 6/10/2021 KHET Subdivision: TR 29894-2 Block: Lot: 279 Issued: 6/18/2021 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 6/3/2022 LIN Valuation: $18,400.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Wednesday, March 01, 2023 3:32:49 PM 1 of 8 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0085 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL CONTRACTOR simon chavero 82417 priscilla ct indio CA 92201 (760)574-6512 info@silveradofire.com OWNER ROBERT & IRENE S. ROVNER 53497 VIA PISA LA QUINTA CA 92253 (760)574-6512 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $161.00 $161.00 6/18/21 WEB8547 054319 CREDIT simon chavero EPRS FIRE PLAN REVISION SUBMITTALS 101-0000-42420 0 $161.00 $161.00 7/2/21 WEB8662 749680 CREDIT simon chavero EPRS FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $242.00 $242.00 6/15/21 WEB8511 005616 CREDIT simon chavero EPRS FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $242.00 $242.00 6/15/21 WEB8511 005616 CREDIT simon chavero EPRS FIRE STAFF - PER HOUR 101-0000-42420 1 $83.00 $83.00 4/13/22 WEB11401 636599881 27 CREDIT simon chavero EPRS Total Paid for FIRE FEES: $889.00 $889.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 6/15/21 WEB8511 005616 CREDIT simon chavero EPRS Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 6/15/21 WEB8511 005616 CREDIT simon chavero EPRS Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$904.00 $904.00 Printed: Wednesday, March 01, 2023 3:32:49 PM 2 of 8 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0085 DATE DATE OVERHEAD HYRO KHET 6/17/2021 6/17/2021 DISAPPROVE D a reinspection is required due to the following. 1. Several areas noted require clearance from HVAC diffusers. 2. Many areas still required adequate protection of the CPVC pipe from contact with jacketed electrical wiring. 3. A leak was identified at one 90-fitting. 4. Significant changes to the pipe routing was observed. OVERHEAD ROUGH PIPING KHET 6/17/2021 6/17/2021 DISAPPROVE D a reinspection is required due to the following. 1. Several areas noted require clearance from HVAC diffusers. 2. Many areas still required adequate protection of the CPVC pipe from contact with jacketed electrical wiring. 3. A leak was identified at one 90-fitting. 4. Significant changes to the pipe routing was observed. OVERHEAD HYRO KHET 7/14/2021 7/14/2021 APPROVED OVERHEAD ROUGH PIPING KHET 7/14/2021 7/14/2021 APPROVED FIRE FINAL**LIN 6/3/2022 6/3/2022 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 4/22/2021 5/6/2021 5/6/2021 REVISIONS REQUIRED SEE ATTACHMENTS PARENT PROJECTS Printed: Wednesday, March 01, 2023 3:32:49 PM 3 of 8 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0085 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 4/22/2021 EtrakitPublicReg 1ST SUBMITTAL SPRINKLERS Senju Residential Conceled Pendant (1).pdf 1 DOC 4/22/2021 EtrakitPublicReg 1ST SUBMITTAL CVWD Rovner - CVWD Letter (1).pdf 1 DOC 4/22/2021 EtrakitPublicReg 1ST SUBMITTAL FP-3 Robert Rovner Residence.pdfDetails.pd f 1 DOC 4/22/2021 EtrakitPublicReg 1ST SUBMITTAL FP-2 Robert Rovner Residence.pdf2nd Floor SPK.pdf 1 DOC 4/22/2021 EtrakitPublicReg 1ST SUBMITTAL FP-5 Robert Rovner Residence.pdf2nd Floor RCP.pdf 1 DOC 4/22/2021 EtrakitPublicReg 1ST SUBMITTAL FP-1 Robert Rovner Residence.pdf1st Floor SPK.pdf 1 BOND INFORMATION 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 4/22/2021 4/23/2021 4/22/2021 COMPLETE 2ND FIRE (1 WK)KOHL HETRICK 5/9/2021 5/17/2021 5/20/2021 REVISIONS REQUIRED 2nd Submittal 3RD FIRE (1 WK)KOHL HETRICK 6/3/2021 6/10/2021 6/10/2021 APPROVED SEE ATTACHMENTS 1ST FIRE (1 WK)KOHL HETRICK 6/18/2021 6/25/2021 6/28/2021 REVISIONS REQUIRED REVISION 1 - SEE ATTACHMENTS CORRECTIONS ARE LOCATED IN ATTACHMENTS. 2ND FIRE (1 WK)KOHL HETRICK 7/2/2021 7/9/2021 7/12/2021 APPROVED REVISION 2 SEE APPROVED REVISIONS IN ATTACHMENTS Printed: Wednesday, March 01, 2023 3:32:49 PM 4 of 8 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0085 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 4/22/2021 EtrakitPublicReg 1ST SUBMITTAL FP-4 Robert Rovner Residence.pdf1st Floor RCP.pdf 0 DOC 4/22/2021 EtrakitPublicReg 1ST SUBMITTAL HYDAULI CALCULATIONS Document.pdfCalc-1 (9).pdf 1 DOC 5/9/2021 EtrakitPublicReg 2nd Floor SPK.pdf 1 DOC 5/9/2021 EtrakitPublicReg Senju Residential Conceled Pendant (3).pdf 1 DOC 5/9/2021 EtrakitPublicReg Rovner - CVWD Letter (2).pdf 1 DOC 5/9/2021 EtrakitPublicReg Robert Rovner Residence.pdfDetail 1st Correction.pdf 1 DOC 5/9/2021 EtrakitPublicReg Robert Rovner Residence.pdf2nd floor RCP (1).pdf 1 DOC 5/9/2021 EtrakitPublicReg Robert Rovner Residence.pdf1st Floor SPK (1).pdf 1 DOC 5/9/2021 EtrakitPublicReg Robert Rovner Residence.pdf1st Floor RCP (1).pdf 1 DOC 5/9/2021 EtrakitPublicReg Document.pdfCalc-2 (3).pdf 1 DOC 5/9/2021 EtrakitPublicReg Document.pdfCalc-1 (16).pdf 1 DOC 6/3/2021 EtrakitPublicReg Rovner - CVWD Letter (3).pdf 1 Printed: Wednesday, March 01, 2023 3:32:49 PM 5 of 8 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0085 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/3/2021 EtrakitPublicReg Robert Rovner Residence.pdfDetails (1).pdf 1 DOC 6/3/2021 EtrakitPublicReg Robert Rovner Residence.pdf2nd SPK.pdf 1 DOC 6/3/2021 EtrakitPublicReg Robert Rovner Residence.pdf2nd RCP.pdf 1 DOC 6/3/2021 EtrakitPublicReg Robert Rovner Residence.pdf1st SPK.pdf 1 DOC 6/3/2021 EtrakitPublicReg Robert Rovner Residence.pdf1st RCP.pdf 1 DOC 6/3/2021 EtrakitPublicReg Senju Residential Conceled Pendant (7).pdf 1 DOC 6/3/2021 EtrakitPublicReg Document.pdfCalc-1 (20).pdf 1 DOC 6/18/2021 EtrakitPublicReg Robert Rovner Residence.pdfDETAIL 2ndCor.pdf 1 DOC 6/18/2021 EtrakitPublicReg Rovner - CVWD Letter (4).pdf 1 DOC 6/18/2021 EtrakitPublicReg Robert Rovner Residence.pdf2nd Floor 2ndCor.pdf 1 DOC 6/18/2021 EtrakitPublicReg Document.pdfCalc-3 (3).pdf 1 Printed: Wednesday, March 01, 2023 3:32:49 PM 6 of 8 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0085 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/18/2021 EtrakitPublicReg Robert Rovner Residence.pdf1st Floor2ndCOR.pdf 1 DOC 6/18/2021 EtrakitPublicReg Senju Residential Conceled Pendant (8).pdf 1 DOC 7/2/2021 EtrakitPublicReg Document.pdfCalc-3 (4).pdf 1 DOC 7/2/2021 EtrakitPublicReg Senju Residential Conceled Pendant (9).pdf 1 DOC 7/2/2021 EtrakitPublicReg Rovner - CVWD Letter (5).pdf 1 DOC 7/2/2021 EtrakitPublicReg Robert Rovner Residence.pdf1st floor 3rd.pdf 1 DOC 7/2/2021 EtrakitPublicReg Robert Rovner Residence.pdf2nd floor 3rd.pdf 1 DOC 7/2/2021 EtrakitPublicReg Robert Rovner Residence.pdfDetails 3rd.pdf 1 DOC 4/13/2022 JULIA AGGREH FSS2021-0085 extension letter.pdf FSS2021-0085 extension letter.pdf 0 DOC 5/6/2021 KOHL HETRICK FSS2021-0085 - 1ST PC - PLAN CORRECTIONS.pdf FSS2021-0085 - 1ST PC - PLAN CORRECTIONS.pdf 1 DOC 5/6/2021 KOHL HETRICK FSS2021-0085 - 1ST PC - FIRE CORRECTION LETTER.pdf FSS2021-0085 - 1ST PC - FIRE CORRECTION LETTER.pdf 1 Printed: Wednesday, March 01, 2023 3:32:49 PM 7 of 8 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0085 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 5/20/2021 KOHL HETRICK FSS2021-0085 - 2ND PC - FIRE CORRECTION LETTER.pdf FSS2021-0085 - 2ND PC - FIRE CORRECTION LETTER.pdf 1 DOC 5/20/2021 KOHL HETRICK FSS2021-0085 - 2ND PC - PLAN CORRECTIONS.pdf FSS2021-0085 - 2ND PC - PLAN CORRECTIONS.pdf 1 DOC 6/10/2021 KOHL HETRICK FSS2021-0085 - COA AND JOB CARD.pdf FSS2021-0085 - COA AND JOB CARD.pdf 1 DOC 6/10/2021 KOHL HETRICK FSS2021-0085 - APPROVED PLANS AND CALCS.pdf FSS2021-0085 - APPROVED PLANS AND CALCS.pdf 1 DOC 6/17/2021 KOHL HETRICK FSS2021-0085 - insp notes.pdf FSS2021-0085 - insp notes.pdf 1 DOC 6/28/2021 KOHL HETRICK FSS2021-0085 - REVISED PLANS AND CALCS - CORRECTIONS.pdf FSS2021-0085 - REVISED PLANS AND CALCS - CORRECTIONS.pdf 1 DOC 6/28/2021 KOHL HETRICK FSS2021-0085 - REVISED PLANS AND CALCS PC - FIRE CORRECTION LETTER.pdf FSS2021-0085 - REVISED PLANS AND CALCS PC - FIRE CORRECTION LETTER.pdf 1 DOC 7/12/2021 KOHL HETRICK FSS2021-0085 - REVISED PLANS-CALCS - APPROVED.pdf FSS2021-0085 - REVISED PLANS-CALCS - APPROVED.pdf 1 Printed: Wednesday, March 01, 2023 3:32:49 PM 8 of 8 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0085 APPROVEDBy:FIRE SAFETY SPECIALIST07/12/2021 7:47:26 AMThe approval of plans and specifications does notpermit the violation, deletion, omission or faultyinstallation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remainaccessible and exposed for inspection purposesuntil approved by the Fire Department.PERMIT # -FSS2021-0085REVISED PLANS & CALCS - AS-BUILT CONDITIONS*NOTES IN THIS COLOR, ADDED BY PLAN REVIEWERFOR CLARITY AND UNDERSTANDING. GREAT ROOM DINING KITCHEN MEDIA POWDER BEDROOM 2 SERVICE POOL ROOM MASTER BEDROOM MASTER BATH BEDROOM 3 ENTRY TOWER STAIRS GARAGE GARAGE CASITA LIVING BATH 2 BATH 3 LESS THAN 55sf LESS THAN 55sf LESS THAN 55sf LESS THAN 55sf LESS THAN 55sf OPEN COURT YARD PATIO ENTRY MASTER CLOSET 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0"10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 14'-10" 14'-10" 14'-10" 14'-10" 11'-6" 10'-0"10'-0" 10'-0" 10'-0" 10'-0" 10'-0" SOFFIT 9'-6" Soffit 9'-0" Soffit 9'-0" Soffit 9'-0" Soffit 9'-0" RISER UP TO 2nd Floor Bath and Gym Up to 2nd Floor UP TO 2nd Floor Dog House UP TO 2nd Floor 5' - 0" 1" 3' -7" 1" 0' -3"1"8' -0"1"16' -0"1" 4' -1" 1" 4' -6"1"4' -0"1" 12' -0"1"15' -4"1"8' -7"1" 6' -3"1" 4' -0"1"9' -0"1" 1' -7"1"2' -9"1"1' -5"1" 12' -0"1"16' -0"1" 2' -9"1"3' -5"1" 0' -7"1"16' -0"1" 0' -11" 1" 1' -6"1"12' -0"1" 2' -2" 1" 6' -10" 1" 0' -5"1" x 4' -0"1"10' -10"1" x 10' -0"1" x 10' -0"2" 26' -6"2" x 4' -0"1" x 7' -9"1" 5' -10"1" x 2' -3"1"3' -0"1" 2' -0"1" x 10' -0"1" 5' -0"1"8' -0"1"4' -0"1" 1' -5"1"1' -5"1" 10' -10" 1" 5' -0" 1" 7' -11" 1" 3' -0"1" x 5' -0"1" 18' -6" 1" 0' -3"1"11' -9"1"11' -2"1" 3' -0" 1" 4' -5"1"6' -3"1" 2' -7"1"5' -11"1"1' -11"1" x 9' -0"1" 7' -5"1"11' -11"1" 1' -11"1" x 19' -0"1" 5' -2" 1" 1' -2"1"6' -8"1" 5' -2"1"6' -10"1"4' -2"1" 2' -3" 1" 6' -4"1"4' -2"1" 6' -11" 1" 0' -5" 1" 3' -5" 1" 1' -10" 1" 5' -5" 1" 11' -4" 1" 3' -6" 1" 3' -1" 1" 5' -7" 1" 3' -1"1"3' -1"1"6' -5"1" 6' -9"1"0' -5"1" 5' -8" 1" 0' -9"1"1' -6"1" 0' -6"1"8' -1"1" 4' -5"1"11' -0"1" 3' -9" 1" 2' -0" 1" 4' -6"1"11' -0"1" 10' -6" 1" 1' -6" 1" 7' -5"1"6' -2"1" 2' -3"1" x 4' -0"1" 2' -11"1"4' -0"1" 4' -6"1" 4' -0" 1" 4' -2"1"8' -10"1" 4' -2"1"2' -10"1"1' -11"1" x 1' -0"1" 1' -0"1"9' -6"1" 4' -9" 1" 1' -0"1"22' -3"1" x 6' -0"1" 9' -7"1"1' -3"1" 0' -8"1"2' -3"1" 1' -11"1"5' -2"1" 5' -9" 1" 3' -5" 1" 2' -1" 1" 1' -6" 1" 1' -2"1"6' -11"5' - 6" simon@silveradofire.com Scale Project number Date Drawn by Checked by Silverado Fire ProtectionPO Box 11474Palm Desert, Ca.92255760-574-6512C-16 # 1068664 1/8" = 1'-0"7/2/2021 8:10:18 AMFP-1 Sprinkler Plan 1st Floor 3rd Correction Project Number 04-20-21 JA SC No. Description Date ROBERT ROVNER RESIDENCEHIDEWAY LOT 27953495 Via PisaLa Quinta, Ca. 92253APN: 777-190-0041/8" = 1'-0"1 1st Floor Sprinkler Plan Sprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 61 SS8486 Concealed Pendent Light Hazard Quick Response1/2 Orifice 3mm GB 4.9 1/2" 162 °F 162 °F: 61 12 SS8486 Concealed Pendent Light Hazard Quick Response1/2 Orifice 3mm GB 4.9 1/2" 205 °F 205 °F: 12 Total No. of Sprinklers: 73 N TOR BOR DOM 9 5 BR2 BR1 1" x 10' - UP TO 2ND BR3 1" x 10' - DOWN FROM 2ND FLR DOG HOUSE. CREATES LOOP ELEMENT 1" WATER METER SOR7 2" X 147' PVC VANITY VANITY +60" BATH 6 BATH 5 BATH 4 BEDROOM 4 BEDROOM 5 GYM LOFT OPEN COURT YARD BALCONEY 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" HALL 1" Water Meter CLG. 6'4" UP from 1st Floor Down to 1st Floor Garage Down to 1st Floor Garage UP from 1st Floor Supply Point Water Supply Information Static Pressure: Residual Pressure: Residual Flow: Additional Hose Flow: 63.20 psi 48.28 psi 32 GPM 0 GPM 8 1 SOR TOR BOR 6 7 DOM 4 2 3 5 Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-3 R-3 2 0.05 Gpm/SqFt 512 Max SqFt 31.2153 GPM 31.9945 Psi 5 GPM 0 GPM 1" 6' -1" 1" 8' -0"1"3' -4"1" 4' -6" 1" 1' -6"1"2' -3"1" 1' -11" 1" 2' -7"1"3' -6"1" 1' -1" 1" 14' -8"1"0' -11"1" 2' -7"1"5' -10"1" x 10' -0"1" 3' -3" 1" 3' -9" 1" 3' -1" 1" 0' -11" 1" 0' -6"1"5' -3"1"9' -4"1" 11' -6"1"1' -0"1" 2' -5" 1" 5' -10" 1" 8' -4" 1" 0' -10" 1" 0' -6"1"5' -3"1" 2' -10" 1" 1' -11" 1" 2' -5" 1" 6' -7" 1" 0' -8" 1" 5' -6" 1" 2' -9"1"1' -0"1" 6' -2" 1" 3' -7" 1" 8' -10"1" x 10' -0"1"8' -6"1" 2' -10" 1" 7' -2"1" x 10' -0"1" 3' -4"1" x 10' -0"1"9' -0"1" 2' -6"1" x 10' -0"CALC-3 1" x 1' -9"2" x 4' -0"2" 26' -6"2"86' -7"1" x 8' -3"1" 1' -0" 1" 0' -8"1"0' -5"1" 0' -7" 1" 3' -1"1" x 10' -0"1" 1' -8"1"16' -9"1" 4' -7"1"13' -4"1" 1' -2"1"5' -2"1" 7' -5" 1" 11' -6"1"14' -6"1" x 10' -0"1" x 10' -0"1" 19' -6"1"1' -6"1" 1' -6"1"6' -0"1" 3' -0" 1" 4' -6"1"6' -9"1" 2' -4" 1" 10' -10" 1" 0' -8" 1" 0' -11" 1" 4' -6"1"43' -0"1" x 5' -0"1" 4' -2"1" x 5' -0"1"8' -10"1" 19' -6"1"3' -5"1" 18' -7"1"42' -8"1" 0' -10" 1" 1' -0" 1" 4' -8" 1" 0' -11" 1" 3' -7" TR2 BR2 TR3 BR3 TR1 BR1 9 simon@silveradofire.com Scale Project number Date Drawn by Checked by Silverado Fire ProtectionPO Box 11474Palm Desert, Ca.92255760-574-6512C-16 # 1068664 1/8" = 1'-0"7/2/2021 8:09:44 AMFP-2 Sprinkler Plan 2nd Floor 3rd Correction Project Number 04-20-21 JA SC No. Description Date ROBERT ROVNER RESIDENCEHIDEWAY LOT 27953497 Via PisaLa Quinta, Ca. 92253APN: 777-190-0041/8" = 1'-0"1 2nd Floor Sprinkler Plan Sprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 61 SS8486 Concealed Pendent Light Hazard Quick Response1/2 Orifice 3mm GB 4.9 1/2" 162 °F 162 °F: 61 12 SS8486 Concealed Pendent Light Hazard Quick Response1/2 Orifice 3mm GB 4.9 1/2" 205 °F 205 °F: 12 Total No. of Sprinklers: 73 1ST FLOOR PIPING THAT WAS SHOWN FOR CALCULATION HAS BEEN COVERED OVER TO ELIMINATE CONFUSION. Silverado Fire Protection PO Box 11474 Palm Desert, Ca. 92255 760-574-6512 Job Name : Robert Rovner Residence Drawing : Location : 53495 Via Pisa Remote Area : Calc-3 Contract : Data File : Robert Rovner Residence Area Calc-3.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 Silverado Fire ProtectionPage 1 Robert Rovner ResidenceDate 10203040E50R60U70S80S90E100R110P12013014015010 20 30 40 50 60 70 80 90FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 63.2 C2 - Residual Pressure: 48.28 C2 - Residual Flow : 32 D1 - Elevation : 9.961 D2 - System Flow : 31.215 D2 - System Pressure : 31.994 Hose ( Demand ) : _______D3 - System Demand : 31.215 Safety Margin : 16.955 D1D2Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.54.4What elevation areyou equating? Silverado Fire ProtectionPage 2 Robert Rovner ResidenceDate Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.54.4 Silverado Fire Protection Page 3 Robert Rovner Residence Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure SOR 63.2 48.28 32.0 48.95 31.22 31.994 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 1 20.0 4.9 7.04 13.0 0.05 256 2 21.0 7.14 3 21.0 7.91 4 21.0 9.88 TR1 21.0 10.78 BR1 11.0 15.4 5 11.0 19.15 TOR 11.0 19.91 DOM 2.74 25.2 5.0 BOR 1.0 26.38 6 1.0 28.65 7 -3.0 31.99 SOR -3.0 31.99 8 20.0 4.9 7.27 13.21 0.05 256 TR3 21.0 8.18 BR3 11.0 12.69 9 11.0 15.51 TR2 21.0 10.3 BR2 11.0 14.73 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.54.4 Silverado Fire Protection Page 4 Robert Rovner Residence Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 1 20 4.90 13.00 1 N 7.0 10.350 150 7.040 to 7.000 -0.433 2 21 13.0 1.101 17.350 0.0307 0.532 Vel = 4.38 2 21 13.22 1 R 1.0 0.910 150 7.139 to O 5.0 6.000 0.0 3 21 26.22 1.101 6.910 0.1123 0.776 Vel = 8.84 3 21 -9.51 1 3R 3.0 32.350 150 7.915 to O 5.0 8.000 0.0 4 21 16.71 1.101 40.350 0.0488 1.968 Vel = 5.63 4 21 -7.12 1 2O 10.0 32.170 150 9.883 to 2R 2.0 19.000 0.0 TR1 21 9.59 1.101 N 7.0 51.170 0.0175 0.893 Vel = 3.23 TR1 21 0.0 1 N 7.0 10.000 150 10.776 to 7.000 4.331 BR1 11 9.59 1.101 17.000 0.0175 0.297 Vel = 3.23 BR1 11 0.0 1 12N 84.0 124.670 150 15.404 to O 5.0 90.000 0.0 5 11 9.59 1.101 R 1.0 214.670 0.0175 3.746 Vel = 3.23 5 11 16.63 1 6.770 150 19.150 to 0.0 TOR 11 26.22 1.101 6.770 0.1123 0.760 Vel = 8.84 TOR 11 0.0 1 N 7.0 8.260 150 19.910 to 7.000 3.577 DOM 2.74 26.22 1.101 15.260 0.1123 1.714 Vel = 8.84 DOM 2.74 + 5.00 5.00 1 R 1.0 1.740 150 25.201 to 1.000 0.754 BOR 1 31.22 1.101 2.740 0.1547 0.424 Vel = 10.52 BOR 1 0.0 1 2N 14.0 0.670 150 26.379 to 14.000 0.0 6 1 31.22 1.101 14.670 0.1551 2.275 Vel = 10.52 6 1 0.0 2 4N 44.0 146.510 150 28.654 to 44.000 1.732 7 -3 31.22 2.003 190.510 0.0084 1.602 Vel = 3.18 7 -3 0.0 1.5 0.260 150 31.988 to 0.0 SOR -3 31.22 1.598 0.260 0.0231 0.006 Vel = 4.99 0.0 SOR 31.22 31.994 K Factor = 5.52 8 20 4.90 13.21 1 N 7.0 1.480 150 7.273 to R 1.0 8.000 -0.433 2 21 13.21 1.101 9.480 0.0315 0.299 Vel = 4.45 0.0 2 13.21 7.139 K Factor = 4.94 3 21 9.51 1 N 7.0 3.570 150 7.915 to O 5.0 12.000 0.0 TR3 21 9.51 1.101 15.570 0.0171 0.267 Vel = 3.20 TR3 21 0.0 1 10.000 150 8.182 to 4.331 BR3 11 9.51 1.101 10.000 0.0172 0.172 Vel = 3.20 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 Silverado Fire Protection Page 5 Robert Rovner Residence Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf BR3 11 0.0 1 10N 70.0 94.210 150 12.685 to 70.000 0.0 9 11 9.51 1.101 164.210 0.0172 2.823 Vel = 3.20 9 11 7.12 1 4N 28.0 40.320 150 15.508 to 2R 2.0 35.000 0.0 5 11 16.63 1.101 O 5.0 75.320 0.0484 3.642 Vel = 5.60 0.0 5 16.63 19.150 K Factor = 3.80 4 21 7.12 1 2R 2.0 13.180 150 9.883 to 3N 21.0 28.000 0.0 TR2 21 7.12 1.101 O 5.0 41.180 0.0101 0.415 Vel = 2.40 TR2 21 0.0 1 10.000 150 10.298 to 4.331 BR2 11 7.12 1.101 10.000 0.0101 0.101 Vel = 2.40 BR2 11 0.0 1 3N 21.0 51.180 150 14.730 to O 5.0 26.000 0.0 9 11 7.12 1.101 77.180 0.0101 0.778 Vel = 2.40 0.0 9 7.12 15.508 K Factor = 1.81 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. They are decorative and fast responding. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows for easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for residential occupancies and is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar1/2) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents to escape or evacuate in case of a fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. “Lead Free” is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA’s Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. Approvals: Sprinkler Identification Number (SIN): Maximum Working Pressure: Discharge Coefficient (Nominal K-Factor): Temperature Rating: Color Code (Sprinkler) Color Code (Cover Plate) Vertical Adjustment: Cover Plate Finishes: Standard Finishes- Custom Finishes- Please see chart on Page 8 for more detail. Physical Characteristics: In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is reached, internal components of the sprinkler fall apart. This leads to the water flow to be distributed on the affected fire area. (Ref. Figure 2) DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. Locations of sprinklers must follow the obstruction rules of NFPA 13, 13D and 13R for Residential Sprinklers. The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Refer to NFPA 13D, 13R or 13 for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to the exposure of a heat source other than an actual fire. Available Sprinkler Temperature Ratings Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating Maximum Ambient Ceiling Temperature Temperature Rating of the Cover Plate Assembly Ordinary 162°F (72°C) 100°F (38°C) 140°F (60°C) Intermediate 175°F (79°C 150°F (66°C) 140°F (60°C) 1) Intermediate 175°F (79°C) 150°F (66°C) 162°F (72°C) 1) Maximum ambient temperature for the Cover Plate Assembly is 100°F (38°C). Model RC-RES sprinklers should not be installed where they may be subjected to a corrosive environment including the following: Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) – Solder Joint) All residual flux must be removed from the interior and exterior of the copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and/or leakage in the sprinkler system. The minimum required sprinkler flow rates for systems designed to NFPA 13D or 13R are given in TABLE A as a function of temperature rating and the maximum allowable coverage area. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of “design sprinklers” as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in TABLE A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. A minimum discharge of 0.1GPM/sq.ft. [4.07LPM/sq.m] over the “design area” comprised of the four most hydraulically demanding sprinklers for the actual coverage area being protected by the four sprinklers. For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R or 13 as applicable. Ordinary Temperature Rating 162°F (72°C) Intermediate Temperature Rating 175°F (79°C) Maximum Coverage Area(a) Ft. × Ft. (m ×m) Maximum Spacing Ft. (m) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) 12×12 (3.7×3.7) 12 (3.7) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 14×14 (4.3×4.3) 14 (4.3) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 15×15 (4.6×4.6) 15 (4.6) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 16×16 (4.9×4.9) 16 (4.9) 13 (49.2) 7.0 (0.48) 14 (53.0) 8.2 (0.57) 18×18 (5.5×5.5) 18 (5.5) 17 (64.3) 12.0 (0.83) 18 (68.1) 13.5 (0.93) 20×20 (6.1×6.1) 20 (6.1) 21 (79.5) 18.4 (1.27) Smooth Ceilings 3/8 to 7/8 Inches. Beamed Ceilings per NFPA 13D, 13R or 13 Installed in beam 3/8 to 7/8 inches below bottom of beam. Concealed 8 (2.4) (a) For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. TABLE A) The Model RC-RES must be installed in accordance with the following instructions: The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inches (50.8mm) as shown in Figure 3. With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Socket NR-H or Ratchet (3/8” drive) & Socket NR-H Combination (Ref. Figure 4). The teeth of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). If desired, the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with a 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the “Vertical Adjustment” indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just has contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot contact the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6. The following instructions must be implemented for the maintenance and service of the Model RC-RES. When placing an order, please contact a local distributor with the following information (Model Name, Temperature Rating and Finish). Model: RC-RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162°F (72°C) or 175°F (79°C) ) 2-5/8 inch (68mm) or 3-1/4 inch (83mm) or 2-5/8 inch square (68mm), Order Separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. Standard Finishes Custom Finishes 2-5/8" Round, 140°F - - - - - - 3-1/4" Round, 140°F 2-5/8" Square, 140°F - - - - - - - 2-5/8" Round, 162°F - - - - - - - 3-1/4" Round, 162°F - - - - - - - Socket NR-H For use with a 3/8” drive ratchet (not included) Socket NR-H Plastic For use with a 1/2” drive ratchet (not included) Cap Remover RC OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org June 10, 2021 Silverado Fire Protection PO Box 11474 Palm Desert, CA 92255 Re: Residential Fire Sprinkler Plan Review – ROVNER RESIDENCE FSS2021-0085 / 53497 VIA PISA, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 53497 VIA PISA PERMIT#: FSS2021-0085 DATE ISSUED: 6/10/2021 DESCRIPTION: ROVNER RESIDENCE CONTRACTOR: SILVERADO FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. 82417 Priscilla Ct INDIO CA, 92201 C-16 #1068664 4/12/2022 www.silveradofire.com 760-600-0765 Info@silveradofire.com Permit: #FSS2021-0085 Job name: Rosenberg residence Address: Re: Extension for residential project. Hello, I would like an extension on the permit. The project is ready to move forward and is ready for fire sprinklers to finish up. The building schedule ran longer than expected. Best regards, Simon Chavero Silverado Fire Protection 760-600-0765