FSS2021-0154ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL KOHL HETRICK 7/12/2021 7/12/2021 Blake, The submittal is missing some documents and details. Plans do not show hydraulic node points. No hydraulic calculation packets were provided. No Water Supply information was provided. Trying to hold off on sending it back right away, hoping it is a quick fix. Please let me know if you can provide this to me be end of day tomorrow. Thank you, KOHL HETRICK Description: EMARD / NEW NFPA 13D AUTOMATIC FIRE SPRINKLER SYSTEM Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 6/27/2021 ECON Parcel No: 766042005 Site Address: 79092 S TOM FAZIO LANE LA QUINTA,CA 92253 Approved: 3/27/2022 KHET Subdivision: TR 27728 Block: Lot: 11 Issued: ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 1/26/2023 KHET Valuation: $11,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 62 HEADS Printed: Thursday, March 02, 2023 10:14:55 AM 1 of 7 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0154 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT WORLD FIRE PROTECTION INC 41-905 BOARDWALK STE B PALM DESERT CA 92211 (760)565-6030 bchapman@worldfirep rotection.com CONTRACTOR WORLD FIRE PROTECTION INC 41-905 BOARDWALK STE B PALM DESERT CA 92211 (760)565-6030 bchapman@worldfirep rotection.com OWNER LEE OPOLINSKY 2618 MANDEVILLE CANYON LOS ANGELES CA 0 (760)565-6030 E-MAIL KOHL HETRICK 4/7/2022 4/7/2022 EMAILED CONTRACTOR AND DESIGNER THE EXTENSIVE INSPECTION NOTES. CONDITIONS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE FAILED OR ADDITIONAL FIELD INSPECTIONS (EXCESSIVE) EACH 101-0000-42421 0 $175.00 $175.00 1/16/23 WEB14062 789003236 CREDIT 1049720 ECON FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $167.00 $167.00 4/8/22 WEB11347 636499352 48 CREDIT 1049720 ECON FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $167.00 $167.00 9/12/22 WEB13027 723485047 CREDIT 1049720 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $250.00 $250.00 3/28/22 WEB11165 636242218 80 CREDIT 1049720 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $250.00 $250.00 3/28/22 WEB11165 636242218 80 CREDIT 1049720 ECON Total Paid for FIRE FEES: $1,009.00 $1,009.00 Printed: Thursday, March 02, 2023 10:14:55 AM 2 of 7 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0154 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 4/5/2022 4/5/2022 CANCELED Rob called early and requested to cancel. *No Fee. OVERHEAD HYRO KHET 4/5/2022 4/5/2022 CANCELED Rob called early and requested to cancel. *No Fee. OVERHEAD ROUGH PIPING KHET 4/7/2022 4/7/2022 DISAPPROVE D SEE ATTACHMENTS Significant changes require revised plans and calculations to be reviewed and approved prior to final. *Bucket test is still required prior to final as well. OVERHEAD HYRO KHET 4/7/2022 4/7/2022 DISAPPROVE D no pressure on system OVERHEAD ROUGH PIPING KHET 4/11/2022 4/11/2022 APPROVED SEE NOTES Revised plans and calcs required. Bucket Test Required. Additional Insp Notes to be sent to designer. Okay to insulate and cover. Minor corrections to be confirmed at Bucket Test or Final OVERHEAD HYRO KHET 4/11/2022 4/11/2022 APPROVED DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 3/28/22 WEB11165 636242218 80 CREDIT 1049720 ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 3/28/22 WEB11165 636242218 80 CREDIT 1049720 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$1,024.00 $1,024.00 Printed: Thursday, March 02, 2023 10:14:55 AM 3 of 7 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0154 MAIN DRAIN - INSPECTORS TEST KHET 8/24/2022 8/24/2022 DISAPPROVE D Bucket Test - SEE NOTES BUCKET TEST (NOT FINAL YET) NOT READY. - EQUIPMENT NOT IN PLACE AND READY FOR TEST AS COMMUNICATED. OBSERVED PRV VALVE ON THE WATER SUPPLY THAT WILL RESTRICT FLOW. REINSPECTION WITH FEES APPLICABLE IS REQUIRED. MAIN DRAIN - INSPECTORS TEST LRO 9/14/2022 9/14/2022 APPROVED BUCKET TEST FIRE FINAL**KHET 1/11/2023 1/11/2023 DISAPPROVE D Clean As-builts required Multiple issues with Standard Temp heads located too close to HVAC diffusers. Missing Trim Changed heads not corrected. Smoke Detector Obstructions *Clean As-built plans based on inspection notes from 4/2022 and 1/11/2023 are required prior to final inspection. Not a review. FIRE FINAL**KHET 1/26/2023 1/26/2023 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 6/27/2021 7/12/2021 7/14/2021 INCOMPLETE Plans do not show hydraulic node points. No hydraulic calculation packets were provided. No Water Supply information was provided. 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 6/27/2021 6/28/2021 6/28/2021 COMPLETE 2ND FIRE (1 WK)KOHL HETRICK 7/19/2021 7/26/2021 7/27/2021 REVISIONS REQUIRED SEE ATTACHMENTS 3RD FIRE (1 WK)KOHL HETRICK 3/11/2022 3/18/2022 3/27/2022 APPROVED SEE ATTACHMENTS PARENT PROJECTS Printed: Thursday, March 02, 2023 10:14:55 AM 4 of 7 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0154 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/28/2021 AARON HICKSON 1ST SUBMITTAL SPRINKLER PLAN COMBINED.pdf 1ST SUBMITTAL SPRINKLER PLAN COMBINED.pdf 1 DOC 6/27/2021 EtrakitContractor 1ST SUBMITTAL SPRINKLER SPECIFICATIONS VK-494 4.9 k Res 155 deg.pdf 1 DOC 7/19/2021 EtrakitContractor Calcs Document.pdfCalc-1.pdf 1 DOC 7/19/2021 EtrakitContractor Piping Plan with Calc Area Emard Residence.pdfPiping.pdf 1 DOC 7/19/2021 EtrakitContractor RCP Emard Residence.pdfRCP.pdf 1 DOC 7/19/2021 EtrakitContractor Site Emard Residence.pdfSite.pdf 1 DOC 7/19/2021 EtrakitContractor Water Flow Scanned from a Xerox Multifunction Printer (01B).pdf 1 DOC 7/19/2021 EtrakitContractor Sprink Head Cut Sheet VK-494 4.9 k Res 155 deg_1.pdf 1 DOC 3/11/2022 Etrakit Contractor Cut Sheet VK-494 4.9 k Res 155 deg_2.pdf 1 DOC 3/11/2022 Etrakit Contractor Scanned from a Xerox Multifunction Printer (01B)_1.pdf 1 DOC 3/11/2022 Etrakit Contractor Fp1 thru FP3 Emard Residence.pdfSite 1st Corr-merged.pdf 1 BOND INFORMATION 4TH FIRE - ETRAKIT (1 WK) KEVIN MEREDITH 4/8/2022 4/15/2022 As-built Plans & Calcs Printed: Thursday, March 02, 2023 10:14:55 AM 5 of 7 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0154 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 3/11/2022 Etrakit Contractor Calcs Document.pdfCalc- 1_1.pdf 1 DOC 4/8/2022 Etrakit Contractor Casita Calcs Document.pdfCalc-1 Casita.pdf 1 DOC 4/8/2022 Etrakit Contractor Casita Calcs Document.pdfCalc-2.pdf 1 DOC 4/8/2022 Etrakit Contractor Sprinkler Cut Sheet Globe GL4906 4.9K.pdf 1 DOC 4/8/2022 Etrakit Contractor Scanned from a Xerox Multifunction Printer (01B)_2.pdf 1 DOC 4/8/2022 Etrakit Contractor As Build Plans Emard Residence As- Builds.pdf 1 DOC 1/16/2023 Etrakit Contractor As-Builds with updated heads As Build Piping.pdf 1 DOC 1/23/2023 Etrakit Contractor As Build updated Emard Residence.pdfPiping As Build (1).pdf 1 DOC 7/27/2021 KOHL HETRICK FSS2021-0154 - 1ST PC - CORRECTIONS LETTER.pdf FSS2021-0154 - 1ST PC - CORRECTIONS LETTER.pdf 1 DOC 7/27/2021 KOHL HETRICK FSS2021-0154 - 1ST PC - CORRECTIONS.pdf FSS2021-0154 - 1ST PC - CORRECTIONS.pdf 1 DOC 3/27/2022 KOHL HETRICK FSS2021-0154 - APPROVED PLANS AND CALCS.pdf FSS2021-0154 - APPROVED PLANS AND CALCS.pdf 1 DOC 3/27/2022 KOHL HETRICK FSS2021-0154 - COA AND JOB CARD.pdf FSS2021-0154 - COA AND JOB CARD.pdf 1 DOC 4/7/2022 KOHL HETRICK FSS2021-0154 - 4-7-2022 INSP NOTES.pdf FSS2021-0154 - 4-7-2022 INSP NOTES.pdf 1 DOC 9/14/2022 KOHL HETRICK Bucket Test Procedures.pdf Bucket Test Procedures.pdf 1 Printed: Thursday, March 02, 2023 10:14:55 AM 6 of 7 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0154 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 1/11/2023 KOHL HETRICK FSS2021-0154 - 1-11- 2023 INSP NOTES.pdf FSS2021-0154 - 1-11- 2023 INSP NOTES.pdf 1 DOC 1/23/2023 KOHL HETRICK FSS2021-0154 - APPROVED AS-BUILT PLANS.pdf FSS2021-0154 - APPROVED AS-BUILT PLANS.pdf 1 DOC 9/15/2022 LEILANI ROJAS FSS2021-0154 Bucket Test.pdf FSS2021-0154 Bucket Test.pdf 0 Printed: Thursday, March 02, 2023 10:14:55 AM 7 of 7 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0154 World Fire Protection 41905 Boardwalk Suite B Your Street Address 2 Palm Desert, Ca. 92211 760-565-6030 Job Name : Emard Residence Drawing : Location : 79092 Tom Fazio Lane Remote Area : Calc-1 Contract : Data File : Emard Residence Area Calc-1.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 World Fire ProtectionPage 1 Emard ResidenceDate 10203040E50R60U70S80S90E100R110P120130140150200 400 600 800 1000 1200 1400 1600 1800FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 36.87 C2 - Residual Pressure: 20.98 C2 - Residual Flow : 1250 D1 - Elevation : 6.496 D2 - System Flow : 31.193 D2 - System Pressure : 31.229 Hose ( Demand ) : _______D3 - System Demand : 31.193 Safety Margin : 5.624 D1D2Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.54.4 World Fire ProtectionPage 2 Emard ResidenceDate Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.54.4 World Fire Protection Page 3 Emard Residence Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure SOR 36.87 20.98 1250.0 36.853 31.19 31.229 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 1 12.0 4.9 7.04 13.0 0.05 256 2 12.0 8.12 3 12.0 8.3 4 12.0 13.8 5 13.0 13.98 6 13.0 14.16 7 13.0 14.29 17 14.0 14.03 18 14.0 14.27 9 11.0 15.76 19 11.0 15.79 10 11.0 15.84 20 11.0 17.69 21 11.0 18.08 TOR 11.0 18.12 DOM 0.91 22.86 5.0 BOR -3.0 24.88 22 -3.0 25.4 WM -3.0 30.4 16 -3.0 31.23 SOR -3.0 31.23 11 12.0 4.9 7.25 13.19 0.05 256 12 13.0 14.17 13 13.0 14.22 14 13.0 14.29 15 13.0 14.62 8 11.0 15.73 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.54.4 World Fire Protection Page 4 Emard Residence Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 1 12 4.90 13.00 1 3N 21.0 14.310 150 7.040 to 21.000 0.0 2 12 13.0 1.101 35.310 0.0307 1.083 Vel = 4.38 2 12 0.0 1.25 4R 4.0 13.990 150 8.123 to 4.000 0.0 3 12 13.0 1.394 17.990 0.0097 0.175 Vel = 2.73 3 12 13.19 1.25 3R 3.0 95.960 150 8.298 to 7N 56.0 59.000 0.0 4 12 26.19 1.394 154.960 0.0355 5.504 Vel = 5.51 4 12 -9.83 1 N 7.0 1.000 150 13.802 to O 5.0 12.000 -0.433 5 13 16.36 1.101 13.000 0.0469 0.610 Vel = 5.51 5 13 0.0 1.25 R 1.0 11.250 150 13.979 to 1.000 0.0 6 13 16.36 1.394 12.250 0.0149 0.182 Vel = 3.44 6 13 -2.84 1.25 2R 2.0 10.260 150 14.161 to 2.000 0.0 7 13 13.52 1.394 12.260 0.0104 0.128 Vel = 2.84 7 13 -5.30 1 N 7.0 1.000 150 14.289 to O 5.0 12.000 -0.433 17 14 8.22 1.101 13.000 0.0132 0.171 Vel = 2.77 17 14 0.0 1.25 4R 4.0 53.300 150 14.027 to 4.000 0.0 18 14 8.22 1.394 57.300 0.0042 0.238 Vel = 1.73 18 14 0.0 1 N 7.0 3.000 150 14.265 to O 5.0 12.000 1.299 9 11 8.22 1.101 15.000 0.0132 0.198 Vel = 2.77 9 11 5.30 1.25 R 1.0 1.780 150 15.762 to 1.000 0.0 19 11 13.52 1.394 2.780 0.0104 0.029 Vel = 2.84 19 11 0.0 1.5 R 1.0 8.480 150 15.791 to 1.000 0.0 10 11 13.52 1.598 9.480 0.0054 0.051 Vel = 2.16 10 11 12.67 1.5 5R 5.0 88.440 150 15.842 to O 8.0 13.000 0.0 20 11 26.19 1.598 101.440 0.0183 1.852 Vel = 4.19 20 11 0.0 1.25 N 8.0 1.790 150 17.694 to R 1.0 9.000 0.0 21 11 26.19 1.394 10.790 0.0356 0.384 Vel = 5.51 21 11 0.0 1.5 2.400 150 18.078 to 0.0 TOR 11 26.19 1.598 2.400 0.0179 0.043 Vel = 4.19 TOR 11 0.0 1.5 N 9.0 10.090 150 18.121 to R 1.0 10.000 4.370 DOM 0.91 26.19 1.598 20.090 0.0183 0.367 Vel = 4.19 DOM 0.91 + 5.00 5.00 1.5 N 9.0 3.910 150 22.858 to 9.000 1.693 BOR -3 31.19 1.598 12.910 0.0253 0.326 Vel = 4.99 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 World Fire Protection Page 5 Emard Residence Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf BOR -3 0.0 2 2N 22.0 39.700 150 24.877 to 22.000 0.0 22 -3 31.19 2.003 61.700 0.0084 0.519 Vel = 3.18 22 -3 0.0 1.5 0.260 150 25.396 to 5.000 * * Fixed Loss = 5 WM -3 31.19 1.598 0.260 0.0231 0.006 Vel = 4.99 WM -3 0.0 1.5 O 8.0 24.720 150 30.402 to 8.000 0.0 16 -3 31.19 1.598 32.720 0.0252 0.826 Vel = 4.99 16 -3 0.0 8 88.910 140 31.228 to 0.0 SOR -3 31.19 8.27 88.910 0 0.001 Vel = 0.19 0.0 SOR 31.19 31.229 K Factor = 5.58 11 12 4.90 13.19 1 2N 14.0 14.310 150 7.248 to O 5.0 19.000 0.0 3 12 13.19 1.101 33.310 0.0315 1.050 Vel = 4.44 0.0 3 13.19 8.298 K Factor = 4.58 4 12 9.83 1 R 1.0 25.970 150 13.802 to N 7.0 18.000 -0.433 12 13 9.83 1.101 2O 10.0 43.970 0.0183 0.804 Vel = 3.31 12 13 2.85 1.25 R 1.0 4.280 150 14.173 to 1.000 0.0 13 13 12.68 1.394 5.280 0.0093 0.049 Vel = 2.67 13 13 0.0 1 R 1.0 1.340 150 14.222 to 1.000 0.0 14 13 12.68 1.101 2.340 0.0295 0.069 Vel = 4.27 14 13 0.0 1.25 2R 2.0 33.970 150 14.291 to 2.000 0.0 15 13 12.68 1.394 35.970 0.0093 0.333 Vel = 2.67 15 13 0.0 1 2O 10.0 2.000 150 14.624 to 10.000 0.866 10 11 12.68 1.101 12.000 0.0293 0.352 Vel = 4.27 0.0 10 12.68 15.842 K Factor = 3.19 6 13 2.84 1.25 O 6.0 13.720 150 14.161 to R 1.0 7.000 0.0 12 13 2.84 1.394 20.720 0.0006 0.012 Vel = 0.60 0.0 12 2.84 14.173 K Factor = 0.75 7 13 5.30 1 4R 4.0 71.300 150 14.289 to 2O 10.0 28.000 0.866 8 11 5.3 1.101 2N 14.0 99.300 0.0058 0.579 Vel = 1.79 8 11 0.0 1.25 R 1.0 14.000 150 15.734 to 1.000 0.0 9 11 5.3 1.394 15.000 0.0019 0.028 Vel = 1.11 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 World Fire Protection Page 6 Emard Residence Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 0.0 9 5.30 15.762 K Factor = 1.33 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 APRIL 2019 GFS-360 PAGE 1 of 4 SERIES GL-RES/INCH RESIDENTIAL ADJUSTABLE FLAT PLATE THE INCH® CONCEALED PENDENT K-FACTOR 4.9 TECHNICAL DATA Approvals •cULus - EU K-Factor •K4.9 gpm/psi½ (70.6 lpm/bar½) Temperature Rating •Sprinkler: 155°F (68°C) •Cover Plate: 135°F (57°C) Cover Plate Finishes •Chrome/White Painted (For painted plates other than white, contact Customer Service) Thread Size •1/2” NPT (15mm) Vertical Adjustment •1” (25mm) Nominal Maximum Working Pressure •175 psi (12 bar) Materials of Construction •Frame - bronze •• Screw - brass •Lodgement Wire - stainless steel • Bulb seat - copper •Spring - nickel alloy • •Bulb (3mm) - glass •Cover Plate - brass • Concealed Cup - carbon steel 4077 Airpark Dr.Standish, MI 48658 • 989-846-4583 • www.globesprinkler.com Technical Support • 989-414-2600 •techservice@globesprinkler.com NOTE: GENERAL DESCRIPTION The GL4906 Adjustable Flat Plate Concealed pendent sprinkler is a decorative fast response glass bulb sprinkler - tions such as homes, apartments, hotels, and dormitories to the chance for occupants to escape. The GL4906 utilizes a 3mm frangible glass bulb as its heat sensing operating ele- ment. While providing the optimal aesthetic appeal with the the largest vertical adjustment in the industry of a nominal 1”. This nominal 1” adjustment allows for previously unrec- dwelling occupancies as allowed by NFPA 13, 13D, 13R and any other related documents as appropriate. OPERATION The soldered cover plate drops off the retainer assembly which is connected to two guide pins, drops down below the ceiling into its intended position. As heat encompasses release of the water seat assembly, and discharge of water from the sprinkler. SERIES GL-RES/INCH GL4906 APRIL 2019 GFS-360 PAGE 2 of 4 1 1/4"MAX. 1/4"MIN.CEILING DESIGN CRITERIA The Globe Concealed Pendent Sprinkler (GL4906) is cULus Listed for installation in accordance with this data sheet as well as the applicable installation Standard being utilized. Globe Residential Sprinkler Installation Guide - vided criteria, refer to the Globe Residential Sprinkler Instal- lation Guide (Document GFS-380) for recommendations that may be acceptable to the authority having jurisdiction. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the mini- - imum required discharge from each of the total number of Hydraulic Design (NFPA 13) The minimum required discharge from each design area sprinkler shall be the greater of the following: (1) TABLE A. (2)In rooms or compartments greater than 800 ft2 (74.3 m2), calculated based on delivering a minimum of 0.1 gpm/ft2 (4.1 mm/min) over the coverage area of each sprinkler, calculated in accordance with the (3)In rooms or compartments 800 ft2 (74.3 m2) or less de- livering a minimum of 0.1 gpm/ft2 (4.1 mm/min) over the room or compartment using the area of the room divided by the number of sprinklers in the room.(7 psi minimum) FIGURE 1: GL4906 INSTALLED POSITION FIGURE 2: GL4906 ACTIVATED POSITION 3 5/16" DIA. 2 3/4" MAX. 1 7/8" MIN. 1/8"CEILING COVER PLATE SUPPORT SHELL CUP DEFLECTOR DROP PIN 1" x 1/2" REDUCER 2 3/8" DIA. CEILING 2 3/4" DIA. MIN. HOLE IN CEILING SIN STYLE MAX.AREA OF COVERAGE MINIMUM PRESSURE MINIMUM FLOW DEFLECTOR TO CEILING DISTANCE MINIMUM DISTANCE BETWEEN SPRINKLERS GL4906 THE INCH® ADJUSTABLE CONCEALED PENDENT 7.0 (.48)13 (49)Smooth Ceilings (When sprinkler is in activated position) Beamed Ceilings - Adjacent Allowed in ceiling. Beamed Ceilings - In Beam (When sprinkler is in activated position) 9 (2.7) 7.0 (.48)13 (49) 7.0 (.48)13 (49) 12.0 (.83)17 (64) 16.7 (1.15)20 (76) TABLE A: NFPA 13, 13R, AND 13D HYDRAULIC AND INSTALLATION DESIGN CRITERIA FOR GL4906 CONCEALED SPRINKLER NOTE: APRIL 2019 GFS-360 PAGE 3 of 4 CARE AND MAINTENANCE Step 1.Install pendent sprinklers in the pendent position, with the centerline of the sprinkler perpendicular to the mounting surface. Step 2.Remove the Protective Cap. Step 3.With pipe-thread sealant applied to the pipe threads, and using the Concealed Sprinkler Wrench P/N 332765 (FIGURE 6), install and tighten the Sprinkler/Concealed Cup Assembly Step 4.Replace the Protective Cap by pushing it upwards until it bottoms out against the Sup- port Cup. The Protective Cap helps prevent ceiling installation and/or during application of NOTICE: The system is considered Out of Service when Step 5.After the ceiling has been completed with the 2-3/4” (70mm) diameter hole, remove and discard the Protective Cap and verify that the does not move up and down freely, replace the entire sprinkler assembly. Do not attempt to modify or repair. Step 6.Push on the Cover Plate Assembly until its screw on the Cover Plate Assembly such that it lifts a ceiling panel out of its normal posi- tion. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover - ly to contact the ceiling, the Sprinkler Fitting must be repositioned. Always obtain permission from the proper authorities to personnel who may be affected by this action before closing work on the system that it controls. Sprinklers should only be cleaned by means of gently dusting with a feather dust- - tent operation may result. When properly installed, there is a nominal 1/8” (3mm) air gap between the Cover Plate and the ceiling (FIGURE 1). This air gap is necessary for proper operation of the sprin- above the Cover Plate to help assure appropriate release of be maintained and should never be sealed or caulked. Factory painted Cover Plates must not be repainted. In accordance with NFPA 25, Sprinklers which are found to replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. before, during, and after installation. Sprinklers damaged by dropping, striking, wrench slippage, or similar incidents, must be replaced. The owner is responsible for the inspection, testing, and compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (e.g. NFPA 25), in addition to the standards of any other authorities having jurisdiction. Refer to Globe’s Residential Installation Guide for further Care and Maintenance information. INSTALLATION FIGURE 3: HAND HELD INSTALLATION TOOL P/N 332875 FIGURE 4: INSTALLATION TOOL USED WITH EXTENSION P/N 332876 FIGURE 5: PROTECTIVE CAP P/N 332871 FIGURE 6: CONCEALED WRENCH P/N 332765 APRIL 2019 GFS-360 PAGE 4 of 4 ORDERING INFORMATION GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. List Terms and Conditions of Sale (Our Price List). 4077 Airpark Dr.Standish, MI 48658 • 989-846-4583 • www.globesprinkler.com Technical Support • 989-414-2600 •techservice@globesprinkler.com Sprinkler/Cup Assembly Specify: Qty. •P/N . . . . . . . . . . . . . . . . . . . . .GL490615501 Cover Plate Assembly Finish Specify: Qty. • P/N 135°F (57°C) Chrome . . . . . . . . . . . . . . .332891 135°F (57°C) White . . . . . . . . . . . . . . . .332892 Custom Painted: Contact Customer Service Sprinkler Wrench Specify: Qty. • P/N Concealed Wrench .................332765 The Inch Installation Tool Specify: Qty. • P/N Hand Held . . . . . . . . . . . . . . . . . . . . .332875 . . . . . . . . . . . . . . . .332876 Protective Caps Specify: Qty. •P/N . . . . . . . . . . . . . . . . . . . . .332871 FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 1 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 1. DESCRIPTION Viking Freedom® Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile small-diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “push-on”, “thread-off” design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2” (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS UL Listed (C-UL-US-EU): Category VKKW Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) Glass-bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-C51000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 or Stainless Steel UNS-S30400 Spring: Beryllium Nickel Solder: Eutectic (Also refer to the current Viking price list.) Viking Freedom® Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 200 °F (93 °C) = E For example, sprinkler VK494 with a Brass finish and a 200 °F (93 °C) temperature rating = Part No. 20759AE. Base Part No. 13504 (2-3/4” diameter), Base Part No. 13642 (3-5/16” diameter), or Base Part No. 15394 (square cover plate, 3-5/16”) Base Part No. 21876 (2-3/4” diameter) or Base Part No. 21875 (3-5/16” diameter). Replaces Form No. F_012116 Rev 18.1 (Added P65 Warning.) FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 2 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = M-/B Temperature Suffix: 135 °F/57 °C = A For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13504FA. Refer to Table 1. (Also refer to the Viking website.) A. Heavy Duty Part No. 14047W/B** (available since 2006), or B. Head Cabinet Wrench Part No. 14031*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a ½” ratchet (not available from Viking). ***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Part No. 01731A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly. . Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres - sure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. 1 2 3 4 4 4 Ordinary 155 °F (68 °C)100 °F (38 °C)135 °F (57 °C)13504 or 218766 13642 or 218756 15394 Red Intermediate 200 °F (93 °C)150 °F (65 °C)135 °F (57 °C)13504 or 218766 13642 or 218756 15394 Green Brass and ENT 6: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 5: ENT 1.The sprinkler temperature rating is stamped on the deflector. 2.Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3.Maximum ambient temperature for cover assembly is 100 °F (38 °C). 4.Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 5.The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. 6.Stainless Steel versions are not available with any finishes or paint. FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 3 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 1 SIN - U.S.2 20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar) 6 GPM (LPM)3,5 155 °F (68 °C), 200 °F (93 °C) Temperature Rated Sprinklers 4 12 X 12 (3.7 X 3.7) 13 (49.2) 7.0 (0.48) Refer to Figure 2 Concealed with Cover Plate Assembly. See Footnote 8. See Footnotes 7,9, 10, & 11 8 (2.4) 14 X 14 (4.3 X 4.3) 13 (49.2) 7.0 (0.48) 16 X 16 (4.9 X 4.9) 13 (49.2) 7.0 (0.48) 18 X 18 (5.5 X 5.5) 17 (64.4) 12.0 (0.83) 20 X 20 (6.1 X 6.1) 20 (75.7) 16.7 (1.15) 1.Part number shown is the base part number. For complete part number, refer to current Viking price schedule. 2.Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3.This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 4.Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. 5.Meets New York City requirements, effective July 1, 2008. 6.For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum “Flow” and “Pressure” used. 7.Cover Temperature Rating is 135 °F (57 °C). Cover Part No. 135041, 136421 (large diameter), or 153941 (square cover plate). 8.Other paint colors are available on request with the same listings as the standard finish colors. Stainless Steel cover plates are not available with any finishes or paint. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 8. 10.C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) 11.Stainless Steel Cover plate temperature rating is 135 °F (57 °C). Stainless Steel Cover Part Numbers: 218761 and 218751 (large diameter). FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 4 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) : When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover - age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: •The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, •Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. •Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: - • • Step 1: Step 2: FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 5 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 NOTE: to approximately 13/16” (21 mm) below the sprinkler body. All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Replaces Form No. F_012116 Rev 18.1 (Added P65 Warning.) OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org March 27, 2022 World Fire Protection INC 41905 Boardwalk #B Palm Desert, CA 92211 Re: Residential Fire Sprinkler Plan Review – EMARD 79092 S TOM FAZIO LANE, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) *Bucket Test – due to the low-pressure water supply. Contact OFM for specific directions on performing test. (c) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 79092 S TOM FAZIO LANE PERMIT#: FSS2021-0154 DATE ISSUED: 3/27/2022 DESCRIPTION: EMARD CONTRACTOR: WORLD FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS *BUCKET TEST Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.