FSS2021-0155ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL AARON HICKSON 7/30/2021 7/30/2021 APPROVED WITH CONDITIONS AFTER REVIEWING NOTES. NEED BRYAN GEER FITTER CERTIFICATION Description: COMMERICAL FIRE SPRINKLER TI PERMIT / BCOM2020-0034 Type: FIRE SPRINKLER (WEB)Subtype: COMMERCIAL/INDUSTRIAL Status: FINALED Applied: 6/30/2021 EPRS Parcel No: 770020015 Site Address: 50929 WASHINGTON ST STE 2 LA QUINTA,CA 92253 Approved: 7/20/2021 AHI Subdivision: Block: Lot: Issued: 8/2/2021 AMA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 11/1/2021 KHET Valuation: $15,565.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Thursday, March 02, 2023 10:20:31 AM 1 of 13 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0155 E-MAIL KOHL HETRICK 7/13/2021 7/13/2021 Good Morning Kohl, I extended the drops down myself. The GC needed to frame low ceilings to meet his schedule and access to the high ceiling would be severely impacted after the framing was completed. I have not impaired the system nor added any piping that can't be inspected upon rough. I know that we are not technically suppose to start any work until permits are issued, but I've been in this industry for 20 years and on a quick turn around TI, sometimes the rules have to be bent. If you want to proceed with notifying the CSLB, that is your prerogative. I would ask that you have some grace considering the size and scope of this project is miniscule and nothing has been installed that can't still be inspected. No other work has been or will be completed until permits are issued. If you would like to discuss further, you can reach me on my cell number below. Bryan W. Geer, President Alternative Fire Protection Services 951.245.7111 Office 951.245.7222 Fax 951.906.2193 Cell 28701 Hwy 74 Lake Elsinore CA 92532 C-16 941639 From: Valerie Hernandez <valerie@alternativefire.com> Sent: Monday, July 12, 2021 3:57 PM To: Hetrick, Kohl@CALFIRE Cc: 'Kayli Alford'; 'Jose Delgado' Printed: Thursday, March 02, 2023 10:20:31 AM 2 of 13 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0155 E-MAIL KOHL HETRICK 7/12/2021 7/12/2021 Subject: RE: LQ project - 50929 Washington St - FPCBP2100375 Warning: this message is from an external user and should be treated with caution. Hi Kohl, I have forwarded your message to my boss. He will contact you. --- On Mon, Jul 12, 2021 at 3:46 PM, Hetrick, Kohl@CALFIRE <Kohl.Hetrick@fire.ca.gov> wrote: I spoke with the superintendent and in my discussion I discerned that work by your company had been started. Limited, but included the installation of several drops to temporary plugs. I require the name(s) of the individuals that performed the work and I require scans/photos of their Fire Sprinkler Fitter Certifications. This has become a condition of future approval. KOHL HETRICK ---- From: Valerie Hernandez <valerie@alternativefire.com> Sent: Monday, July 12, 2021 3:42 PM To: Hetrick, Kohl@CALFIRE <Kohl.Hetrick@fire.ca.gov> Cc: 'Kayli Alford' <kalford@laquintaca.gov>; 'Jose Delgado' <jodelgado@laquintaca.gov> Subject: RE: LQ project - 50929 Washington St - FPCBP2100375 Warning: this message is from an external user and should be treated with caution. Hi, Understood. Just hoping to be able to get started. That is why we checked. ---- On Mon, Jul 12, 2021 at 2:29 PM, Hetrick, Kohl@CALFIRE <Kohl.Hetrick@fire.ca.gov> wrote: Printed: Thursday, March 02, 2023 10:20:31 AM 3 of 13 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0155 No work should be being conducted without permit being ISSUED. Failure to comply with this normal standard is subject to administrative citation and reporting to CSLB. Repeat offenses are subject to recommendations for La Quinta Business License revocation. We do not offer courtesy inspections. KOHL HETRICK ---- From: Valerie Ray <valerie@alternativefire.com> Sent: Monday, July 12, 2021 2:07 PM To: Hetrick, Kohl@CALFIRE <Kohl.Hetrick@fire.ca.gov> Cc: 'Kayli Alford' <kalford@laquintaca.gov>; 'Jose Delgado' <jodelgado@laquintaca.gov> Subject: RE: LQ project - 50929 Washington St - FPCBP2100375 Warning: this message is from an external user and should be treated with caution. Hi, Thank you for the information. Do you guys do courtesy inspections by chance? Have a great day! If you have any questions or concerns, please feel free to contact me. Thank you, Valerie Hernandez Office Manager ---- Bryan, Thank you for the scans/photos of your crew members certifications. Only Scott Kautz, Mitch Kautz and Rodney Washington will be permitted to perform work on the system once the permit is issued. Printed: Thursday, March 02, 2023 10:20:31 AM 4 of 13 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0155 E-MAIL KOHL HETRICK 7/14/2021 7/14/2021 Jose Serna and Armando Rodriguez appear to have let their certifications expire. Depending on their situation, CCR Title 19, Ch 5.5 following section may apply: Article 5. Certification and Registration § 935. Expired Documents. An Apprentice or Trainee Registration or Fitter Certification, which has expired, shall be considered an original application and the applicant is required to comply with all requirements of an original application. Additionally, you identified yourself (alone) to be the one who performed the work on this system to date. I therefore do require your Sprinkler Fitter Certification information (Current/Expired). Article 4. Enforcement § 927. Violations. The SFM, SFM Designee or AHJ is authorized to inspect project worksites where work on fire protection systems is being performed to ensure that persons performing the work possess valid certifications or registrations as required by this Chapter. The SFM, SFM Designee or AHJ is authorized to require persons performing work to provide proof of applicable certification or registration card. Any person who cannot show proof of certification or registration to the SFM, SFM Designee or AHJ shall be subject to Sections 928 through 932. Thank you, KOHL HETRICK Fire Safety Specialist / Office of the Fire Marshal Cal Fire/Riverside County Fire Department City of La Quinta CAL FIRE/Riverside County Fire Department Desk: 760-777-7074 | Mobile: 760-409-5109 Inspection Hotline: 760-777-7131 78495 Calle Tampico, La Quinta, CA 92253 kohl.hetrick@fire.ca.gov | www.rvcfire.org Sch: Mon-Thurs Printed: Thursday, March 02, 2023 10:20:31 AM 5 of 13 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0155 Leadership, Competence, Integrity, Safety, Customer Service The Office of the County Fire Marshal is committed to facilitating fire and life safety solutions by empowering its employees to serve our community through innovation and partnership. From: Bryan W. Geer <bryan@alternativefire.com> Sent: Wednesday, July 14, 2021 10:06 AM To: Hetrick, Kohl@CALFIRE <Kohl.Hetrick@fire.ca.gov> Subject: Fitter Cards Warning: this message is from an external user and should be treated with caution. Hey Kohl, Here are the current valid fitter cards. One of these guys will be doing the work on the Grocery Outlet TI. Probably Scott and Mitch. Let me know if you have any questions. Thank you, Bryan W. Geer, President Alternative Fire Protection Services 28701 Hwy. 74 Lake Elsinore, CA 92532 951-245-7111 P 951-245-7222 F Printed: Thursday, March 02, 2023 10:20:31 AM 6 of 13 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0155 E-MAIL KOHL HETRICK 7/14/2021 7/14/2021 I don’t have a fitter card. I’ve reapplied as a valid licensed current C-16 Holder, but no test date has been provided. Bryan W. Geer, President Alternative Fire Protection Services 28701 Central Ave. Lake Elsinore CA 92532 (951) 245-7111 P (951) 245-7222 F (951) 906-2193 C E-MAIL KOHL HETRICK 7/20/2021 7/20/2021 ISSUED A NOTICE OF VIOLATION FOR 1) PERFORMING WORK PRIOR TO PERMIT ISSUANCE, AND 2) PERFORMING WORK WITHOUT PROPER SPRINKLER FITTER CERTIFICATION FROM THE STATE FIRE MARSHAL. Printed: Thursday, March 02, 2023 10:20:31 AM 7 of 13 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0155 E-MAIL KOHL HETRICK 8/4/2021 8/4/2021 Bryan, I am clearing the Overhead Rough Inspection with several notes. 1 Affects your existing scope of work but can be addressed/confirmed at final. During the inspection with your crew, I observed issues of concern associated with the existing system that should have been addressed as part of the 5-year Certification conducted by a separate local C-16 contractor. I would like to see these concerns addressed prior to occupancy. It is your discretion if you would like to offer your services to address the concerns in complete detail (full analysis is needed) or defer your client to the originally certifying C-16. I intend to take any analysis of the issues to the C-16 directly with the intent to educate on the expectations and requirements for providing quality service to system owners. Any assistance to identify the issues formally is greatly appreciated. Please let me know if you have any questions. Thank you, KOHL HETRICK Printed: Thursday, March 02, 2023 10:20:31 AM 8 of 13 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0155 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT Alternative Fire Protection Services 28701 Highway 74 Lake Elsinore CA 92532 (951)245-7111 valerie@alternativefire .com BILL TO Alternative Fire Protection Services 28701 Highway 74 Lake Elsinore CA 92832 (951)245-7111 Valerie@alternativefire .com CONTRACTOR ALTERNATIVE FIRE PROTECTION SERVICES 28701 HIGHWAY 74 LAKE ELSINORE CA 92532 (951)245-7111 VALARIE@ALTERNATIV EFIRE.COM OWNER Grocery Outlet, Inc 5650 Hollis St.Emeryville CA 94608 (951)245-7111 TELEPHONE CALL KOHL HETRICK 7/13/2021 7/13/2021 I spoke with Bryan Geer of Alternative Fire Protection Services. I advised of the strict requirement to adhere to no work shall be performed without an Issued permit. I further inquired to the effect of confirming who specifically had performed the work. Geer advised that he did the work by himself without help from others. I inquired in to the fact that I did not observe any cutout coupons secured at the several mechanical fittings for the new arm-overs and drops. Geer advised that he placed them all on a wire and secured at the Fire Riser (will need to confirm). I then inquired into obtaining scans of his and his teams Fire Sprinkler Fitter Certifications. He advised that all of his crew have the various classifications and are in process for renewals. As he was the one who performed the work, I asked for his certification. He advised that he was "the license (C-16) holder." I acknowledged that but informed him that he must still have the Certification and maintain it. He said he would look for it and get it to me. The conversation was ended with my stating of the need to be provided with the Certifications of himself and any crew member to be assigned to work on completing this project. CONDITIONS FINANCIAL INFORMATION Printed: Thursday, March 02, 2023 10:20:31 AM 9 of 13 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0155 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES FIRE INSPECTOR KHET DISAPPROVE D On 7/12/2021 @ 1530 hours I visited the project site out of concern that work was already started prior to permit issuance. I spoke with the Superintendant and confirmed that the fire protection contractor company was already out on 7/11/2021 and installed the many drops outlined in the plans. The Super advised that they were expected back tomorrow (7/13/2021) morning. I advised him that they had performed work prior to permit issuance. DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS COMMERCIAL/INDUSTR IAL 101-0000-42421 0 $242.00 $242.00 8/2/21 WEB8878 073219 CREDIT Bryan Geer EPRS FIRE SPRINKLER SYSTEMS COMMERCIAL/INDUSTR IAL PC 101-0000-42420 0 $403.00 $403.00 8/2/21 WEB8878 073219 CREDIT Bryan Geer EPRS Total Paid for FIRE FEES: $645.00 $645.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 8/2/21 WEB8878 073219 CREDIT Bryan Geer EPRS Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 8/2/21 WEB8878 073219 CREDIT Bryan Geer EPRS Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$660.00 $660.00 Printed: Thursday, March 02, 2023 10:20:31 AM 10 of 13 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0155 FIRE INSPECTOR KHET DISAPPROVE D On 7/13/2021 @ 0730 hours I again visited the project site in hopes of having a face to face with the fire protection contractor crew performing the work. They were not on site. I met with the Superintendant and reviewed the portion of the system that had been installed. I observed many new arm overs and drops to plugs had been installed. I noticed that the mechanical fittings for the new arm-over cut-ins had no retrieved coupon cut-outs secured as proof that they had been retrieved. OVERHEAD HYRO KHET 8/4/2021 8/4/2021 APPROVED OVERHEAD ROUGH PIPING KHET 8/4/2021 8/4/2021 APPROVED SEE NOTES Overhead rough inspection was approved with the additional notes. *Okay to cover. 1) At final, confirm installation of needed upright protection in the area of the new office rooms as affected by the full-height wall and solid truss layout. *Observed several existing issues that should have been addressed by the September 2020 5-Year Certification conducted by a local C-16 contractor. a) Twisted / Angled pipes and heads b) Covered head(s) c) Bent hanger thread rods d) Missing/removed seismic restraint e) Insufficient upright head spacing f) Close proximity head spacing ** Suggested to analyze system for items that were missed in the AES Inspection, Testing and Maintenance required by NFPA 25 and certified by the local C-16 contractor. FIRE FINAL**KHET 10/19/2021 10/19/2021 NOT READY No fee Printed: Thursday, March 02, 2023 10:20:31 AM 11 of 13 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0155 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/30/2021 EtrakitPublicReg 1ST SUBMITTAL PLANS GROCERY OUTLET T.I.- LA QUINTA-PLANS.pdf 1 DOC 6/30/2021 EtrakitPublicReg 1ST SUBMITTAL PRODUCT SUBMITTALS GROCERY OUTLET - LA QUINTA - PRODUCT SUBMITTALS.pdf 1 DOC 7/14/2021 KOHL HETRICK Rodney Washington - FITTER.pdf Rodney Washington.pdf 1 DOC 7/14/2021 KOHL HETRICK Mitch Kautz - FITTER.pdf Mitch Kautz.pdf 1 DOC 7/14/2021 KOHL HETRICK Scott Kautz - FITTER.pdf Scott Kautz.pdf 1 DOC 7/20/2021 KOHL HETRICK 7-20-2021 - NOTICE OF VIOLATION.pdf 7-20-2021 - NOTICE OF VIOLATION.pdf 1 DOC 7/20/2021 KOHL HETRICK FSS2021-0155 - APPROVED PLANS.pdf FSS2021-0155 - APPROVED PLANS.pdf 1 DOC 7/20/2021 KOHL HETRICK FSS2021-0155 - COA AND JOB CARD.pdf FSS2021-0155 - COA AND JOB CARD.pdf 1 BOND INFORMATION FIRE FINAL**KHET 11/1/2021 11/1/2021 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 6/30/2021 7/15/2021 7/20/2021 APPROVED SEE ATTACHMENTS WORK HAS BEEN PERCEIVED TO HAVE STARTED WITHOUT PERMIT ISSUANCE. REQUIRE LIST OF SPRINKLER FITTERS PERFORMING WORK AND THEIR CERTIFICATION. 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 6/30/2021 7/1/2021 6/30/2021 COMPLETE PARENT PROJECTS Printed: Thursday, March 02, 2023 10:20:31 AM 12 of 13 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0155 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 8/4/2021 KOHL HETRICK FSS2021-0155 - ROUGH INSP NOTES - PASS - FLAT.pdf FSS2021-0155 - ROUGH INSP NOTES - PASS - FLAT.pdf 1 Printed: Thursday, March 02, 2023 10:20:31 AM 13 of 13 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0155 SCOPE OF WORK:(1) INSTALL NEW SSP FIRE SPRINKLER HEADS FOR THENEW HARD LID CEILINGS; OFFICES, RESTROOMS,BREAK ROOM AND DRY PENDENT HEADS FOR THENEW WALK-IN COOLERS.(2) THIS IS A NEW TENANT IMPROVEMENT PROJECTONLY.DESIGN CRITERIA:1) This existing building is fully sprinkler and monitored by 24hour central station.2) Attic is combustible construction and fire sprinklers are toremain in place.3) Arm overs 1'-0" or longer to be supported by 3/8" sammy'sscrew,3/8" all thread rod and adjustable hanger rings fastened to2 x 6 and larger joists.4) This new tenant improvement job was designed for LIGHTHAZARD OCCUPANCY 225 sq.ft. maximum spacing persprinkler heads. And designed per 2016 edition of N.F.P.A.#13 andthe 2019 California Fire Code.5) Use standard black steel schedule 30 pipe for all new armovers and drops.6) Pipe fittings shall be class 125 cast iron and 175 psi workingpressure.7) Sprinkler heads are to aligned harmoniously but may not bein center of ceiling tiles.N F P A #13 , 2016 EDITIONSECTION 23.1.2DEVIATION FROM APPROVED PLANS SHALLREQUIRE PERMISSION OF THE AUTHORITYHAVING JURISDICTION.BUILDING CODE DATA:2019 CALIFORNIA BUILDING CODE2019 CALIFORNIA PLUMBING CODE2019 CALIFORNIA MECHANICAL CODE2019 CALIFORNIA ELECTRICAL CODE2019 CALIFORNIA FIRE CODE2019 CALIFORNIA BUILDING CODE / T-242019 CALIFORNIA ENERGY CODEBUILDING INFORMATION :DEVELOPMENT TYPE: RETAILCONS.TYPE: V-BDESCRIPTION USE: MARKETOCCUPANCY: MSTORIES: 1NEW COOLER BOXESCOOLER BOX SECTIONScale : 1/4"=1'-0"COOLER BOX SECTIONScale : 1/4"=1'-0"FREEZERDAIRY COOLERMEAT COOLERTENANT IMPROVEMENTGROCERY OUTLET50929 WASHINGTON SUITE ALA QUINTA , CA. 92253DRY PENDENT HEAD DETAILN.T.S.ARM OVER HANGER DETAILN.T.S.RIVERSIDE COUNTY FIREDEPT. NOTES :a) An owner's manual for the fire sprinkler system shall be provided to the owner.b) A sign or valve tag shall be installed at the main shutoff valve to the water distribution system stating the following: Warning, the water system for this home, supplies fire sprinklers that requires certain flows and pressure to fight a fire. Devises that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler system, such as water softeners, filtration systems and automatic shut off valves,shall not be added to this system without a review of the fire sprinkler system by a fire protection specialist. Do not remove this sign".c) Pendent sprinklers within three feet of the center of a ceiling fan, surface mounted ceiling luminire or similar object shall be considered to be obstructed and additional sprinkler shall be installed.d) A full port ball valve shall be installed as a shut-off valve for both domestic and fire sprinkler water supply. A shut-off valve shall be installed for the domestic water supply after the fire sprinkler system take-off.e) Access panels for the sprinkler riser shall have a sign with an appropriate description.f) Light fixtures, soffits and other potential obstruction shall not interfere with the spray patterns of sprinkler heads. The sprinkler contractor shall insure that the type and location of potential obstructions is considered in the design and installation at the system.The sprinkler contractor is responsible for coordinating and resolving conflicts in coverage patterns.g) The installation of fire sprinkler system shall comply with: * NFPA 13 (2016 Edition) * California Building Code (2019 Edition) * California Residential Code (2019 Edition) * The Riverside County Standard Fire Code. # ALTERNATIVE FIRE PROTECTIONPROJECT:SYMBOL LEDGEND50929 WASHINGTON ST. SUITE ALA QUINTA , CALIFORNIA 92253FSS2021-0155 WMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWM WM WM WMW A S H I N G T O N S T R E E TC A L L E T A M P I C OALL ACCESSIBLEAND PATH OFTRAVEL SITEIMPROVEMENTSBY LANDLORDUNDERSEPARATEPERMIT. PERMIT #BCOM2020-0037HATCH INDICATESAREA OF WORKEXISTINGDUMPSTERENCLOSUREACCESSIBLE PATH TODUMPSTER ENCLOSURE28701 HIGHWAY 74 LAKE ELSINORE, CA.92532 PH (951) 245-7111 FX (951) 245-7222 Lin # C-16 941639 ALTERNATIVE FIRE PROTECTION PROJECT: SYMBOL LEDGEND SITE PLANCONTRACT NO.APPROVALDESIGN BYSCALEDATEREVISEDPLOTTEDFP 2 of 4PERMIT NO.21066RIVERSIDE CO. FIRE DEPT.LUIS HERNANDEZ1/32"=1'-0"REVISION123456789BYDATENoSPRINKLER SCHEDULE AND LEGEND SYMBOL LOCATION SPRINKLER DISCRIPTION TEMP K-FACTOR THRD SIZE TYPE FINISH SIN 1st FLR 2nd FLR TOTAL TOTAL SPRINKLER HEADS PER FLOOR TOTAL REQUIRED SPRINKLER HEADS IN THIS BUILDING GROCERY OUTLET 50929 WASHINGTON ST. SUITE A LA QUINTA , CALIFORNIA 92253JUNE 29, 202120 20 20 OFFICES 155°5.6 1/2 SEMI-RECESSED WHITE TY323 9 0 9TYCO QUICK RESPONSE TY- FRB SEMI-RECESSED PENDENT HEADS COOLERS 200°5.6 1/2 RECESSED WHITE TY3935 11 0 11TYCO QUICK RESPONSE DRY PENDENT HEADS (6") EQUIPMENT ROOMDAIRY COOLERMEAT COOLERBREAK ROOMRESTROOMRESTROOMHALLWAYBACK OFFICEFRONT OFFICE (9'-0) CLG. (9'-0) CLG. (8'-0) CLG. (8'-0) CLG. (8'-0) CLG. (8'-0) CLG. OPEN CLG. OPEN CLG. OPEN CLG. OPEN CLG. OPEN CLG. OPEN CLG.5'-2"FREEZER OPEN TO SKY(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E) 2" MAIN(E) 2" MAIN STOCK ROOMRECEIVINGOUTDOORSTORAGESALES FLOORENTRANCESALES FLOOR(E) 2" MAIN (E) 2" MAIN (E) 2" MAIN (E) 2" MAIN (E) 2" MAIN(E) SSU HEADS TOREMAIN IN PLACE(E) TENANTNOT IN CONTRACT(E) 4" RISER(E) 1½"(E) 1¼"(E) 1"(E) 1"(E) SSU HEADS TOREMAIN IN PLACE(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)1"5'-0"1"4'-6"1"6'-0" 1" 6'-0" 1" 6'-0" 1" 5'-0" 1" 3'-0" 1" 1'-6" 1" 1'-6" 1"1'-6" 1" 3'-2" 1" 3'-2" 1" 3'-2" 1" 5'-4" 1" 3'-4½" 1" 5'-0" 1" 0'-6" 1" 2'-4" 1" 1'-0"(E) BRANCH LINES TOREMAIN IN PLACE(E)(E)(E)(E)(E)(E)PIPING PLANSCALE : 1/8" = 1'- 0"1¼x 1"MECH. TEE1¼"x 1"MECH. TEE OPEN CLG.(E) 1¼"(E) 1¼"(E) 1¼"28701 HIGHWAY 74 LAKE ELSINORE,CA.92532 PH (951) 245-7111 FX (951) 245-7222 Lin # C-16 941639 ALTERNATIVE FIRE PROTECTION PROJECT: SYMBOL LEDGEND EXISTING/NEWSPRINKLER PIPING PLANCONTRACT NO.APPROVALDESIGN BYSCALEDATEREVISEDPLOTTEDFP 3 of 4PERMIT NO.21066RIVERSIDE CO. FIRE DEPT.LUIS HERNANDEZ1/8"=1'-0"REVISION123456789BYDATENoSPRINKLER SCHEDULE AND LEGEND SYMBOL LOCATION SPRINKLER DISCRIPTION TEMP K-FACTOR THRD SIZE TYPE FINISH SIN 1st FLR 2nd FLR TOTAL TOTAL SPRINKLER HEADS PER FLOOR TOTAL REQUIRED SPRINKLER HEADS IN THIS BUILDING GROCERY OUTLET 50929 WASHINGTON ST SUITE A LA QUINTA , CALIFORNIA 92253JUNE 29, 202120 20 20 OFFICES 155°5.6 1/2 SEMI-RECESSED WHITE TY323 9 0 9TYCO QUICK RESPONSE TY- FRB SEMI-RECESSED PENDENT HEADS COOLERS 200°5.6 1/2 RECESSED WHITE TY3935 11 0 11TYCO QUICK RESPONSE DRY PENDENT HEADS (6") EQUIPMENT ROOMDAIRY COOLERMEAT COOLERBREAK ROOMRESTROOMRESTROOMHALLWAYBACK OFFICEFRONT OFFICE (9'-0) CLG. (9'-0) CLG. (8'-0) CLG. (8'-0) CLG. (8'-0) CLG. (8'-0) CLG. OPEN CLG. OPEN CLG. OPEN CLG. OPEN CLG. OPEN CLG. OPEN CLG. OPEN CLG.5'-10 38"3'-238"5'-91316"5'-3116"2'-2 1116"10'-0"2'-2 1116"5'-3116"5'-6916"12'-0"12'-0"5'-6916"5'-0"7'-0"5'-838"6'-012"6'-012"3'-6"10'-0"3'-6" 5'-5 12"6'-6"4'-2"4'-518"6'-078"5'-11316"5'-0316"5'-3 316"5'-212"4'-1112"5'-2" 3'-103 8" 7'-9 116"4'-6 116"1'-934"4'-658"FREEZER(E) TENANTNOT IN CONTRACT OPEN TO SKY(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)(N)REFLECTED CEILING PLANSCALE : 1/8" = 1'- 0"(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)28701 HIGHWAY 74 LAKE ELSINORE,CA.92532 PH (951) 245-7111 FX (951) 245-7222 Lin # C-16 941639 ALTERNATIVE FIRE PROTECTION PROJECT: SYMBOL LEDGEND EXISTING/NEWREFLECTED CEILING PLANCONTRACT NO.APPROVALDESIGN BYSCALEDATEREVISEDPLOTTEDFP 4 of 4PERMIT NO.21066RIVERSIDE CO. FIRE DEPT.LUIS HERNANDEZ1/8"=1'-0"REVISION123456789BYDATENoSPRINKLER SCHEDULE AND LEGEND SYMBOL LOCATION SPRINKLER DISCRIPTION TEMP K-FACTOR THRD SIZE TYPE FINISH SIN 1st FLR 2nd FLR TOTAL TOTAL SPRINKLER HEADS PER FLOOR TOTAL REQUIRED SPRINKLER HEADS IN THIS BUILDING GROCERY OUTLET 50929 WASHINGTON STREET LA QUINTA , CALIFORNIA 92253JUNE 29, 202120 20 20 OFFICES 155°5.6 1/2 SEMI-RECESSED WHITE TY323 9 0 9TYCO QUICK RESPONSE TY- FRB SEMI-RECESSED PENDENT HEADS COOLERS 200°5.6 1/2 RECESSED WHITE TY3935 11 0 11TYCO QUICK RESPONSE DRY PENDENT HEADS (6") 78-495 Calle Tampico, La Quinta CA 92253 Main: 760-777-7000 Direct: 760-777-7074 PAGE _____ OF _____ PERMIT/CASE#: NOTICE NO: FACILITY NAME: DATE: FACILITY ADDRESS: CONTACT: The items below are in violation of or shall meet additional requirements of one or more of the following: CALIFORNIA FIRE CODE __________________ NFPA STD. ______________ CALIFORNIA BUILDING CODE _____________ CCR TITLE ______________ LA QUINTA MUNICIPAL CODE _____________ OTHER ________________ The listed violations/requirements shall be corrected immediately. A re-inspection will be conducted on or after ______________________________ 20____. FAILURE TO COMPLY MAY RESULT IN LEGAL ACTION AND/OR SIGNIFICANT DELAYS FOR APPROVAL. Received By: __________________________________ Signature: _______________________________________ Fire Inspector: _________________________________ Radio I.D.: _______________________________________ IF YOU HAVE ANY QUESTIONS OR NEED ADDITIONAL INFORMATION, PLEASE CALL 760-777-7074. FSS2021-0155 GROCERY OUTLET - TI SPK PERMIT 1 8/4/2021 ALTERNATIVE FIRE PROTECTION 1 1 Overhead rough inspection was approved with the additional notes. *Okay to cover. 1) At final, confirm installation of needed upright protection in the area of the new office rooms as affected by the full-height wall and solid truss layout. *Observed several existing issues that should have been addressed by the September 2020 5-Year Certification conducted by a local C-16 contractor. a) Twisted / Angled pipes and heads b) Covered head(s) c) Bent hanger thread rods d) Missing/removed seismic restraint e) Insufficient upright head spacing f) Close proximity head spacing ** Suggested to analyze system for items that were missed in the AES Inspection, Testing and Maintenance required by NFPA 25 and certified by the local C-16 contractor. bryan@alternativefire.com I-630 5 To find a distributor near you, call 800-BUILDEX Not less than 2” nominal width (1-1/2”) up to 3-1/2” pipe; not less than 3” (2-1/2”) nominal width 4” & 5” pipe Minimum 2-1/2” from bottom for branch lines. Minimum 3” from bottom for main lines. Exception: This requirement shall not apply to 2” or thicker nailing strips resting on top of steel beams. Floor Joist HORIZONTAL MOUNT WOOD WOOD WOOD WOOD WOODSIDEWINDERS® for Wood Installs HORIZONTALLY into the side of wood structures easily and quickly! Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) Box Qty Case Qty 1/4" 8018957 SWG 100 1/4 x 1" 622 (Fir) 25 125 1/4" 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 3/8" 8020957 SWG 10 1/4 x 1" 622 (Fir) 300 25 125 3/8" 8021957 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 3/8" 8073925 SWG 20-SS 1/4 x 2" 1725 (Fir) 850 25 125 3/8" 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 3/8" 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 #14 SW Red Nut Driver Part # 8114910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. INSTALLATION STEPS - VERTICAL INTO WOOD & STEEL: 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 2. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. 3. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. 4. The SAMMYS is now ready to receive 1/4”, 3/8”, 1/2” or metric all thread rod, bolt stock. (The 1/2” requires the #14SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. INSTALLATION STEPS - HORIZONTAL INTO WOOD & STEEL: 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 2. Insert the SAMMYS into the #14SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. 3. When the nut driver spins free on the SAMMYS, stop the drill and remove. 4. The unit is now ready to receive 1/4”, 3/8” or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. Composite/Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for Model SWG 25-380 (tools available on pg 10 ) Product Features • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation cost. • Made in the U.S.A. SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com197 C A S T I R O N A A B A AAA AAASize in Part Number A in B in Packing Weight lbInner Master 1 x 1/2 37RE1010004 1.36 1.26 50 100 0.5 1 x 3/4 37RE1010006 1.45 1.38 40 80 0.7 1-1/4 x 1/2 37RE1012004 1.53 1.34 32 64 0.8 1-1/4 x 3/4 37RE1012006 1.63 1.45 28 56 0.9 1-1/4 x 1 37RE1012010 1.67 1.58 25 50 1.0 1-1/2 x 1/2 37RE1014004 1.75 1.52 25 50 1.0 1-1/2 x 3/4 37RE1014006 1.75 1.52 20 40 1.1 1-1/2 x 1 37RE1014010 1.80 1.65 18 36 1.3 1-1/2 x 1-1/4 37RE1014012 1.88 1.82 14 28 1.5 2 x 1/2 37RE1020004 1.97 1.60 15 30 1.4 2 x 3/4 37RE1020006 1.97 1.60 15 30 1.6 2 x 1 37RE1020010 2.02 1.73 12 24 1.8 2 x 1-1/2 37RE1020014 2.16 2.02 10 20 2.3 Size in Part Number A in Packing Weight lbInner Master 1/2 37E 1004 1.13 90 180 0.3 3/4 37E 1006 1.31 50 100 0.5 1 37E 1010 1.50 35 70 0.8 1-1/4 37E 1012 1.75 20 40 1.3 1-1/2 37E 1014 1.94 15 30 1.7 2 37E 1020 2.25 7 14 2.7 2-1/2 37E 1024 2.70 4 8 4.3 Size in Part Number A in Packing Weight lbInner Master 1 37F 1010 1.26 40 80 0.7 1-1/4 37F 1012 1.29 22 44 1.2 1-1/2 37F 1014 1.44 16 32 1.5 2 37F 1020 1.69 8 16 2.6 Size in Part Number A in Packing Weight lbInner Master 1/2 37T 1004 1.13 60 120 0.4 3/4 37T 1006 1.31 30 60 0.7 1 37T 1010 1.50 20 40 1.1 1-1/4 37T 1012 1.75 12 24 1.8 1-1/2 37T 1014 1.94 8 16 2.4 2 37T 1020 2.25 5 10 3.8 Size in Part Number A in Packing Weight lbInner Master 1 x 1/2 37RC1010004 1.69 60 120 0.5 1 x 3/4 37RC1010006 1.69 50 100 0.6 2 x 1 (not hex) 37RC1020010 2.81 16 32 1.5 Fig. 37E 1 – 90° Elbow Fig. 37RE1 – 90° Reducing Elbow Fig. 37F 1 – 45° Elbow Fig. 37T 1 – Tee Fig. 37RC1 – Hex Coupling Cast Iron Threaded Fittings - Class 125 UL/FM Series DS-1 – 5.6 K-factor, Dry-type Sprinklers Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage Page 1 of 10 MARCH 2019 TFP500 IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide Contacts www.tyco-fire.com General Description TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response (5 mm bulb), Standard Coverage Dry-type Sprinklers are dec- orative glass bulb automatic sprinklers typically used where: • pendent sprinklers are required on dry pipe systems that are exposed to freezing temperatures (for exam- ple, sprinkler drops from unheated portions of buildings) • sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures (for exam- ple, sprinkler drops from wet systems into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping extensions through a wall to protect unheated areas of a building such as loading docks, over- hangs, and building exteriors) • sprinklers are used on systems that are seasonably drained to avoid freezing (for example, vacation resort areas) NOTICE Series DS-1 Dry-type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Series DS-1 Dry-type Sprinklers must only be installed in fittings that meet the requirements of the Design Crite- ria section. Sprinkler Identification Numbers (SINs) TY3255 – Pendent TY3155 – Upright TY3355 – Horizontal Sidewall Technical Data ApprovalsUL and C-UL Listed FM Approved VdS Approved TY3255 w/Standard Escutcheon only NYC Approved under MEA 352-01-ELPCB Approved Reference No. 094a/11 CE Certified Certificate of Conformity No. 0832- CPD-2015 (See Tables A and B for details.) Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connections1 in. NPT ISO 7-R 1 Discharge Coefficient K=5.6 gpm/psi½ (80,6 lpm/bar½) Temperature Ratings See Tables A and B. FinishesSprinkler: See Table D. Escutcheon: See Table D. Physical Characteristics Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Copper Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Copper Yoke .......................Stainless Steel Casing .............Galvanized Carbon Steel Insert . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Bulb Seat . . . . . . . . . . . . . . . . . . . Stainless Steel Bulb (5 mm dia.) . . . . . . . . . . . . . . . . . . . . .Glass Compression Screw . . . . . . . . . . . . . . . . .Bronze Deflector . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Guide Tube . . . . . . . . . . . . . . . . . Stainless Steel Water Tube . . . . . . . . . . . . . . . . . Stainless Steel Spring .....................Stainless Steel Sealing Assembly ..Beryllium Nickel w/TEFLON Escutcheon ....Carbon Steel or Stainless Steel TFP500 Page 2 of 10 SPRINKLER TYPE ESCUTCHEON TYPE TEMPERATURE RATING BULB COLOR CODE SPRINKLER FINISH NATURAL BRASS CHROME PLATED POLYESTER* PENDENT (TY3255) STANDARD 135°F (57°C)Orange 1, 2, 3, 4, 5, 6 1, 2, 4, 5, 6 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 360°F (182°C)Mauve 1, 2, 3, 6 1, 2, 6 RECESSED 135°F (57°C)Orange 1, 2, 3, 5 1, 2, 5155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 1, 2 360°F (182°C)Mauve N/A DEEP 135°F (57°C)Orange 1, 2, 3, 4, 5 1, 2, 4, 5 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 360°F (182°C)Mauve WITHOUT 135°F (57°C)Orange 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 360°F (182°C)Mauve 1, 2, 3 1, 2 UPRIGHT (TY3155)WITHOUT 135°F (57°C)Orange 1, 2, 3, 4, 5 1, 2, 4, 5 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 360°F (182°C)Mauve 1, 2, 3 1, 2 Notes: 1. Listed by Underwriters Laboratories, Inc. (UL), maximum order length of 48 in. 2. Listed by Underwriters Laboratories for use in Canada (C-UL), maximum order length of 48 in. 3. Approved by FM Global (FM Approvals), maximum order length of 48 in. 4. Loss Prevention Certification Board (LPCB) and CE conformity apply to these temperature ratings only 5. Approved by the City of New York under MEA 352-01-E 6. Approved by VdS * Frame and deflector only N/A – Not Applicable TABLE A SERIES DS-1 PENDENT & UPRIGHT DRY-TYPE SPRINKLERS, 5.6K, STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS TFP500 Page 3 of 10 SPRINKLER TYPE ESCUTCHEON TYPE TEMPERATURE RATING BULB COLOR CODE SPRINKLER FINISH NATURAL BRASS CHROME PLATED POLYESTER*** HSW* (TY3355) STANDARD 135°F (57°C)Orange 1**, 2**, 3***, 4, 5 1**, 2**, 4, 5 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 360°F (182°C)Mauve DEEP 135°F (57°C)Orange 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 360°F (182°C)Mauve WITHOUT 135°F (57°C)Orange 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 360°F (182°C)Mauve 1**, 2**, 5 1**, 2** Notes: 1. Listed by Underwriters Laboratories, Inc. (UL), maximum order length of 48 in. 2. Listed by Underwriters Laboratories for use in Canada (C-UL), maximum order length of 48 in. 3. Approved by FM Global (FM Approvals), maximum order length of 48 in. 4. Loss Prevention Certification Board (LPCB) and CE conformity apply to these temperature ratings only 5. Approved by the City of New York under MEA 352-01-E * Horizontal sidewall with top of deflector-to-ceiling distance of 4 to 12 in. (100 to 300 mm) ** Light and ordinary hazard occupancies only *** Light hazard occupancies only **** Frame and deflector only 5 mm BULB WATER TUBE VENT HOLE GUIDE TUBE INSERT YOKE SCREW INLET SEALING PLUG WITH CASING DEFLECTOR BULB SPRING COMPRESSION SEAT ASSEMBLY FRAME INLET BAND RECESS WRENCH FLAT WRENCH WITH SPRINKLER ENGAGEMENT IN TO ENSURE WRENCHING AREA PUSH WRENCH TABLE B SERIES DS-1 HORIZONTAL SIDEWALL (HSW) DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS FIGURE 1 SERIES DS-1 DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE ASSEMBLY FIGURE 2 W-TYPE 7 WRENCH TFP500 Page 4 of 10 2-1/4" DIA. (57,2 mm) 1-3/8" ± 1/8" (34,9 ± 3,2 mm) 2-7/8" DIA. (73,0 mm) IN 1/4" (6,4 mm) 3-3/4" to 48" INCREMENTS (95,3 to 1219,2 mm) ORDER LENGTHS: SPRINKLER FACE OF FITTING CEILING FACE OF SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) ORDER LENGTHS: (69,9 to 1219,2 mm) 2-3/4" to 48" IN 1/4" (6,4 mm) INCREMENTS FITTING FACE OF SPRINKLER (76,2 mm) 3" DIA. 1-3/4" DIA. (44,5 mm) (55,6 ± 3,2 mm) 2-3/16" ± 1/8" CEILING FACE OF SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) ORDER LENGTHS: INCREMENTS 4-1/4" ± 1/8" (108,0 ± 3,2 mm) IN 1/4" (6,4 mm) (12,7 to 1168,4 mm) 1/2" to 46" FACE OF CEILING FITTING FACE OF SPRINKLER (88,9 mm) 3-1/2" DIA. 2-1/2" DIA. (63,5 mm) CRITERIA SECTION) (REFER TO DESIGN SPRINKLER FITTING SPRINKLER FACE OF FITTING (127,0 to 1219,2 mm) INCREMENTS IN 1/4" (6,4 mm) ORDER LENGTHS: 5" to 48" DEFLECTOR TO CEILING 1-3/4" (44,5 mm) MINIMUM SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) TOP OF DEFLECTOR CRITERIA SECTION) (REFER TO DESIGN SPRINKLER FITTING SPRINKLER FITTING FACE OF IN 1/4" (6,4 mm) INCREMENTS (127,0 to 1219,2 mm) 5" to 48" ORDER LENGTHS: FIGURE 3 PENDENT (TY3255) WITH STANDARD ESCUTCHEON FIGURE 5 PENDENT (TY3255) WITH DEEP ESCUTCHEON FIGURE 4 PENDENT (TY3255) WITH STANDARD RECESSED ESCUTCHEON FIGURE 6 PENDENT (TY3255) WITHOUT ESCUTCHEON FIGURE 7 UPRIGHT (TY3155) WITHOUT ESCUTCHEON TFP500 Page 5 of 10 Operation When TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers are in service, water is prevented from entering the assembly by the Plug with Sealing Assembly (see Figure 1) in the Inlet of the sprinkler. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, and the Bulb Seat is released. The compressed Spring is then able to expand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Sealing Assembly from the Inlet, allow-ing the sprinkler to activate and flow water. Design Criteria TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers are intended for use in fire sprinkler systems designed in accordance with the standard instal- lation rules recognized by the appli- cable listing or approval agency (for example, UL Listing is based on NFPA 13 requirements). For more information on LPCB Approval, contact Johnson Controls at the following office: Kopersteden 1 7547 TJ Enschede The Netherlands Tel: +31-(0)53-428-4444 Fax: +31-(0)53-428-3377 Sprinkler Fittings Install 1 in. NPT Series DS-1 Dry-type Sprinklers in the 1 in. NPT outlet or run of the following fittings: • malleable or ductile iron threaded tee fittings that meet the dimen- sional requirements of ANSI B16.3 (Class 150) • cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125) Do not install Series DS-1 Dry-type Sprinklers into elbow fittings. The Inlet of the sprinkler can contact the interior of the elbow. The unused outlet of the threaded tee is plugged as shown in Figure 12. FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) CENTERLINE OF WATERWAY 1-3/4" DIA. (44,5 mm) FACE OF MOUNTING SURFACE ORDER LENGTHS: 2-3/4" to 48" (69,9 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS 3" DIA. (76,2 mm) 5/16" (7,9 mm) 2-3/8" ± 1/8" (60,3 ± 3,2 mm) 3.5° 3.5°5/16" (7,9 mm) CENTERLINE OF WATERWAY FITTING SPRINKLER FACE OF 2-1/4" (57,2 mm) DEFLECTOR TO 5-1/2" to 48" (139,7 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS ORDER LENGTHS: MINIMUM MOUNTING SURFACE SPRINKLER FITTING CRITERIA SECTION) (REFER TO DESIGN FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) CENTERLINE OF WATERWAY FACE OF MOUNTING SURFACE ORDER LENGTHS: 1/2" to 45-3/4" (12,7 to 1162,1 mm) IN 1/4" (6,4 mm) INCREMENTS 5/16" (7,9 mm) 3.5° 2-1/2" DIA. (63,5 mm) 4-1/4" ± 1/8" (108,0 ± 3,2 mm) 3-1/2" DIA. (88,9 mm) FIGURE 8 HORIZONTAL SIDEWALL (TY3355) WITH STANDARD ESCUTCHEON FIGURE 9 HORIZONTAL SIDEWALL (TY3355) WITH DEEP ESCUTCHEON FIGURE 10 HORIZONTAL SIDEWALL (TY3355) WITHOUT ESCUTCHEON TFP500 Page 6 of 10 You can also install Series DS-1 Dry- type Sprinklers in the 1 in. NPT outlet of a GRINNELL Figure 730 Mechanical Tee and GRINNELL G-FIRE Figure 522; however, the use of the Figure 730 Tee and Figure 522 for this arrangement is limited to wet pipe systems. The configuration shown in Figure 13 is only applicable for wet pipe systems where the sprinkler fitting and water- filled pipe above the sprinkler fitting are not subject to freezing and where the length of the dry-type sprinkler has the minimum exposure length depicted in Figure 11. See the Exposure Length section. For wet pipe system installations of 1 in. NPT Series DS-1 Dry-Type Sprin- klers connected to CPVC piping, use only the following TYCO CPVC fittings: • 1 in. x 1 in. NPT Female Adapter (P/N 80145) • 1 in. x 1 in. x 1 in. NPT Sprinkler Head Adapter Tee (P/N 80249) For dry pipe system installations, use only the side outlet of maximum 2-1/2 in. reducing tee when locat- ing Series DS-1 Dry-type Sprinklers directly below the branchline; other- wise, use the configuration shown in Figure 12 to assure complete water drainage from above Series DS-1 Dry-type Sprinklers and the branch- line. Failure to do so may result in pipe freezing and water damage. NOTICE Do not install Series DS-1 Dry-type Sprinklers into any other type fitting without first consulting the Johnson Controls Technical Services. Failure to use the appropriate fitting may result in one of the following: • failure of the sprinkler to operate properly due to formation of ice over the Inlet Plug or binding of the Inlet Plug • insufficient engagement of the Inlet pipe-threads with consequent leakage Drainage In accordance with the minimum requirements of the NATIONAL FIRE PROTECTION ASSOCIATION for dry pipe sprinkler systems, branch, cross, and feed-main piping connected to Dry Sprinklers and subject to freezing tem- peratures must be pitched for proper drainage. Exposure Length When using Dry Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use Table C to determine a sprinkler’s appropriate exposed barrel length to prevent water from freezing in the con- necting pipes due to conduction. The exposed barrel length measurement must be taken from the face of the sprinkler fitting to the surface of the structure or insulation that is exposed to the heated area. See Figure 11 for an example. For protected area temperatures between those given above, the minimum recommended length from the face of the fitting to the outside of the protected area may be determined by interpolating between the indicated values. Clearance Space In accordance with NFPA 13, when connecting an area subject to freez- ing and an area containing a wet pipe sprinkler system, the clearance space around the sprinkler barrel of dry-type sprinklers must be sealed. Due to tem- perature differences between two areas, the potential for the formation of condensation in the sprinkler and subsequent ice build-up is increased. If this condensation is not controlled, ice build-up can occur that might damage the dry-type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB-2 Dry Sprinkler Boot, described in technical data sheet TFP591 and shown in Figures 14 and 15, can provide the recommended seal. Ambient Temperature Exposed to Discharge End of Sprinkler Temperatures for Heated Area(1) 40°F (4°C)50°F (10°C)60°F (16°C) Minimum Exposed Barrel Length(2), in. (mm) 40°F (4°C)0 0 0 30°F (-1°C)0 0 0 20°F (-7°C) 4 (100)0 0 10°F (-12°C)8 (200)1 (25)0 0°F (-18°C)12 (305)3 (75)0 -10°F (-23°C) 14 (355) 4 (100) 1 (25) -20°F (-29°C) 14 (355) 6 (150) 3 (75) -30°F (-34°C)16 (405)8 (200)4 (100) -40°F (-40°C)18 (455)8 (200)4 (100) -50°F (-46°C) 20 (510) 10 (255) 6 (150) -60°F (-51°C) 20 (510) 10 (255) 6 (150) Notes: 1. For protected area temperatures that occur between values listed above, use the next cooler temperature. 2. These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). TABLE C EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS MINIMUM RECOMMENDED LENGTHS TFP500 Page 7 of 10 INSULATED FREEZER STRUCTURE STRAP TIES (ENDS ON OPPOSING SIDES OF BOOT) ADHESIVE DS-1 SHOWN WITH STANDARD ESCUTCHEON 1-3/4" DIA. (44,5 mm) CLEARANCE HOLE DSB-2 BOOT INSULATED FREEZER STRUCTURE STRAP TIES (ENDS ON OPPOSING SIDES OF BOOT) ADHESIVE DS-1 SHOWN WITH STANDARD ESCUTCHEON 1-3/4" DIA. (44,5 mm) CLEARANCE HOLE DSB-2 BOOT SIDE OUTLET PLUGGED TO WET SYSTEM FITTING (SEE DESIGN CRITERIA SECTION) SPRINKLERDSB-2 INTENDED FOR FREEZER STRUCTURES HEATED AREA RUN OUTLET PLUGGED TO DRY SYSTEM DSB-2 INTENDED FOR FREEZER STRUCTURES FITTING (SEE DESIGN CRITERIA SECTION) SPRINKLER AREA SUBJECT TO FREEZING (SEE DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING LENGTH EXPOSURE DSB-2 INTENDED FOR FREEZER STRUCTURES HEATED AREA FIGURE 11 EXPOSURE LENGTH FIGURE 12 SPRINKLER FITTING UNHEATED AREA FIGURE 13 SPRINKLER FITTING HEATED AREA FIGURE 14 MODEL DSB-2 DRY SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY-TYPE SPRINKLER FIGURE 15 MODEL DSB-2 DRY SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY-TYPE SPRINKLER Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Quick Response, Standard Coverage Page 1 of 10 NOVEMBER 2019 TFP510 IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide Contacts www.tyco-fire.com authorities having jurisdiction. Failure to do so may impair the performance of these de vices. The owner is responsible for maintain­ ing their fire protection system and de vices in proper operating condi­ tion. Contact the installing contrac­ tor or product manufacturer with any questions. The Series DS­1 Dry­Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Sprinkler Identification Numbers (SINs) 3/4 in. NPT: TY3935 – Pendent TY3735 – Horizontal Sidewall 1 in. NPT: TY3235 – Pendent TY3135 – Upright TY3335 – Horizontal Sidewall Technical Data Approvals UL and C-UL Listed FM Approved NYC Approved under MEA 352-01-E Previous New York City Approval and MEA certification numbers apply to product as shown in this data sheet. In accordance with Section BC 3502 of the Construction Code, current NYC Approvals for use in the City of New York apply to all products that contain UL or FM Approvals and Listings; therefore, not all products currently Approved for use in the City of New York will carry an actual MEA Certifi- cation number. See Tables A and B. Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connections 3/4 in. NPT 1 in. NPT or ISO 7-R 1 Discharge Coefficient K=5.6 gpm/psi½ (80,6 lpm/bar½) General Description TYCO Series DS-1 Dry-Type Sprinklers, 5.6K Pendent, Upright, and Horizontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage are decora- tive glass bulb automatic sprinklers de signed for commercial use. Dry-type sprinklers are typically used where: • pendent sprinklers are re quired on dry pipe systems that are exposed to freezing temperatures for example, sprinkler drops from unheated portions of buildings • sprinklers and/or a portion of the connecting piping are exposed to freezing temperatures; for example, sprinkler drops from wet sys tems into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping extensions through a wall to protect an unheated areas such as loading docks, overhangs, and building exteriors • sprinklers are used on systems that are seasonally drained to avoid freezing for example, vacation areas NOTICE The Series DS­1 Dry­Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica­ ble standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any Temperature Ratings See Tables A and B Finishes Sprinkler: Natural Brass, Chrome Plated, or Signal White Escutcheon: Signal White, Chrome Plated, or Brass Plated Physical Characteristics Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Copper Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . Copper Yoke .......................Stainless Steel Casing .............Galvanized Carbon Steel Insert . . . . . . . . . . . . . . . . . . . . . . . . . . . Bronze Bulb Seat . . . . . . . . . . . . . . . . . . . Stainless Steel Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Glass Compression Screw . . . . . . . . . . . . . . . . .Bronze Deflector . . . . . . . . . . . . . . . . . . . . . . . . . Bronze Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Guide Tube . . . . . . . . . . . . . . . . . Stainless Steel Water Tube . . . . . . . . . . . . . . . . . Stainless Steel Spring .....................Stainless Steel Plug Spring* . . . . . . . . . . . . . . . . Stainless Steel Sealing Assembly . Beryllium Nickel w/TEFLON Escutcheon ....Carbon Steel or Stainless Steel * For 3/4 in. NPT only TFP510 Page 2 of 10 WATER TUBE VENT HOLE GUIDE TUBE SEALING PLUG WITH DEFLECTOR SPRING ASSEMBLY FRAME 3 mm BULB INSERT YOKE SCREW INLET CASING BULB COMPRESSION SEAT INLET BAND WATER TUBE VENT HOLE GUIDE TUBE 3 mm BULB INSERT SPRING SCREW INLET SEALING PLUG WITH CASING DEFLECTOR BULB YOKE COMPRESSION SEAT ASSEMBLY FRAME SPRING PLUG INLET BAND FIGURE 2 SERIES DS-1, 1 IN. NPT AND ISO 7-R 1 DRY-TYPE SPRINKLER ASSEMBLY FIGURE 1 SERIES DS-1, 3/4 IN. NPT, DRY-TYPE SPRINKLER ASSEMBLY Operation When the TYCO Series DS-1 Dry-Type Sprinklers, 5.6K Pendent, Upright, and Horizontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage are in service, water is prevented from entering the assembly by the Plug with Sealing Assembly in the Inlet of the Sprinkler. See Figures 1 and 2. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, and the Bulb Seat is released. The compressed Spring is then able to expand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Sealing Assembly from the Inlet and allowing the sprin kler to activate and flow water. Design Criteria The TYCO Series DS-1 Dry-Type Sprin- klers, 5.6K Pendent, Upright, and Hor- izontal Sidewall, Quick Response (3 mm bulb) and Standard Cover- age are intended for use in fire sprin- kler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL Listing is based on NFPA 13 requirements. Sprinkler Fittings Install the 3/4 or 1 in. NPT Series DS-1 Dry-Type Sprinklers in the 3/4 or 1 in. NPT outlet or run of the follow- ing fittings: • malleable or ductile iron threaded tee fittings that meet the dimen- sional requirements of ANSI B16.3 (Class 150) • cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125) Do not install the DS-1 Sprinklers into an elbow fittings. The Inlet of the sprinkler can contact the interior of the elbow, potentially damaging the Inlet seal. The unused outlet of the threaded tee is plugged as shown in Figure 13. You can also install the Series DS-1 Dry-Type Sprinklers in the 3/4 or 1 in. NPT outlet of a GRINNELL Figure 730 Mechanical Tee. However, the use of the Figure 730 Tee for this arrangement is limited to wet pipe systems. TFP510 Page 3 of 10 1 in. NPT (and ISO 7-R 1) TY3235 Pendent with Recessed Escutcheon (Figure 4) TY3235 Pendent with Standard Escutcheon (Figure 3) with Deep Escutcheon(Figure 5) without Escutcheon (Figure 6) TY3135 Upright without Escutcheon5 (Figure 7) TY3335 Horizontal Sidewall with Top of Deflector-to-Ceiling Distance of 4 to 12 in. (100 to 300 mm) with Standard Escutcheon (Figure 8) with Deep Escutcheon (Figure 9) without Escutcheon (Figure 10) Temperature Rating Bulb Color Code Finish Natural Brass Chrome Plated White Polyester Natural Brass Chrome Plated White Polyester Natural Brass Chrome Plated White Polyester 135°F (57°C)Orange 1, 2, 3, 4 1, 2, 4 1, 2, 3, 4 1, 2, 4 1*, 2*, 3**, 4 1*, 2*, 4 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 1, 2, 4 Notes: 1. Listed by Underwriters Laboratories, Inc. (maximum order length of 48 in.) 2. Listed by Underwriters Laboratories for use in Canada (maximum order length of 48 in.) 3. Approved by Factory Mutual Research Corporation (maximum order length of 48 in.) 4. Approved by the City of New York under MEA 352-01-E 5. The Upright Sprinkler without an Escutcheon (TY3135) is available in 1 in. NPT only * Light and Ordinary Hazard occupancies only ** Light Hazard occupancies only 3/4 in. NPT TY3935 Pendent with Recessed Escutcheon (Figure 4) TY3935 Pendent with Standard Escutcheon (Figure 3) with Deep Escutcheon (Figure 5) without Escutcheon (Figure 6) TY3735 Horizontal Sidewall with Top of Deflector-to-Ceiling Distance of 4 to 12 in. (100 to 300 mm) with Standard Escutcheon (Figure 8) with Deep Escutcheon (Figure 9) without Escutcheon (Figure 10) Temperature Rating Bulb Color Code Finish Natural Brass Chrome Plated White Polyester Natural Brass Chrome Plated White Polyester Natural Brass Chrome Plated White Polyester 135°F (57°C)Orange 1, 2 1, 2 1*, 2* 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue Notes: 1. Listed by Underwriters Laboratories, Inc. (maximum order length of 48 in.) 2. Listed by Underwriters Laboratories for use in Canada (maximum order length of 48 in.) * Light and Ordinary Hazard occupancies only TABLE A 3/4 IN. NPT SERIES DS-1 QUICK RESPONSE, STANDARD COVERAGE DRY-TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS TABLE B 1 IN. NPT (AND ISO 7-R 1) SERIES DS-1 QUICK RESPONSE, STANDARD COVERAGE DRY-TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP510 Page 4 of 10 2-1/4" DIA. (57,2 mm) 1-3/8" ± 1/8" (34,9 ± 3,2 mm) 2-7/8" DIA. (73,0 mm) IN 1/4" (6,4 mm) 3-3/4" to 48" INCREMENTS (95,3 to 1219,2 mm) ORDER LENGTHS: SPRINKLER FACE OF FITTING CEILING FACE OF CRITERIA SECTION) (REFER TO DESIGN SPRINKLER FITTING ORDER LENGTHS: INCREMENTS 4-1/4" ± 1/8" (108,0 ± 3,2 mm) IN 1/4" (6,4 mm) (12,7 to 1168,4 mm) 1/2" to 46" FACE OF CEILING (88,9 mm) 3-1/2" DIA. 2-1/2" DIA. (63,5 mm) FITTING FACE OF SPRINKLER CRITERIA SECTION) (REFER TO DESIGN SPRINKLER FITTING ORDER LENGTHS: (69,9 to 1219,2 mm) 2-3/4" to 48" IN 1/4" (6,4 mm) INCREMENTS FITTING FACE OF SPRINKLER SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) (76,2 mm) 3" DIA. 1-3/4" DIA. (44,5 mm) (55,6 ± 3,2 mm) 2-3/16" ± 1/8" CEILING FACE OF SPRINKLER FACE OF FITTING (127,0 to 1219,2 mm) INCREMENTS IN 1/4" (6,4 mm) ORDER LENGTHS: 5" to 48" DEFLECTOR TO CEILING 1-3/4" (44,5 mm) MINIMUM SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) TOP OF DEFLECTOR CRITERIA SECTION) (REFER TO DESIGN SPRINKLER FITTING SPRINKLER FITTING FACE OF IN 1/4" (6,4 mm) INCREMENTS (127,0 to 1219,2 mm) 5" to 48" ORDER LENGTHS: FIGURE 5 PENDENT TY3235 AND TY3935 WITH DEEP ESCUTCHEON FIGURE 6 PENDENT TY3235 AND TY3935 WITHOUT ESCUTCHEON FIGURE 3 PENDENT TY3235 AND TY3935 WITH STANDARD ESCUTCHEON FIGURE 4 PENDENT TY3235 AND TY3935 WITH RECESSED ESCUTCHEON FIGURE 7 UPRIGHT TY3135 WITHOUT ESCUTCHEON 1 IN. NPT ONLY TFP510 Page 5 of 10 3.5°5/16" (7,9 mm) CENTERLINE OF WATERWAY FITTING SPRINKLER FACE OF 2-1/4" (57,2 mm) DEFLECTOR TO 5-1/2" to 48" (139,7 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS ORDER LENGTHS: MINIMUM MOUNTING SURFACE SPRINKLER FITTING CRITERIA SECTION) (REFER TO DESIGN FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) CENTERLINE OF WATERWAY FACE OF MOUNTING SURFACE ORDER LENGTHS: 1/2" to 45-3/4" (12,7 to 1162,1 mm) IN 1/4" (6,4 mm) INCREMENTS 5/16" (7,9 mm) 3.5° 2-1/2" DIA. (63,5 mm) 4-1/4" ± 1/8" (108,0 ± 3,2 mm) 3-1/2" DIA. (88,9 mm) FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) CENTERLINE OF WATERWAY 1-3/4" DIA. (44,5 mm) FACE OF MOUNTING SURFACE ORDER LENGTHS: 2-3/4" to 48" (69,9 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS 3" DIA. (76,2 mm) 5/16" (7,9 mm) 2-3/8" ± 1/8" (60,3 ± 3,2 mm) 3.5° FIGURE 8 TY3335 AND TY3735 HORIZONAL SIDEWALL WITH STANDARD ESCUTCHEON FIGURE 9 TY3335 AND TY3735 HORIZONAL SIDEWALL WITH DEEP ESCUTCHEON FIGURE 10 TY3335 AND TY3735 HORIZONAL SIDEWALL WITHOUT ESCUTCHEON The configuration shown in Figure 12 is only applicable for wet pipe systems where the sprinkler fitting and water- filled pipe above the sprinkler fitting are not subject to freezing and where the length of the Dry-Type Sprinkler has the minimum exposure length depicted in Figure 11. See the Exposure Length section. For wet pipe system installations of the 1 in. NPT Series DS-1 Dry-Type Sprin- klers connected to CPVC piping, use only the following TYCO CPVC fittings: • 1 in. x 1 in. NPT Female Adapter (P/N 80145) • 1 in. x 1 in. x 1 in. NPT Sprinkler Head Adapter Tee (P/N 80249) For wet pipe system installations of the the 3/4 in. NPT Series DS-1 Sprinklers connected to CPVC piping, use in the 3/4 in. x 3/4 in. NPT Female Adapter (P/N 80142). For dry pipe system installations, use only the side outlet of maximum 2 1/2 in. reducing tee when locating the Series DS-1 Sprinklers directly below the branch line. Otherwise, use the con- figuration shown in Figure 13 to assure complete water drainage from above the Series DS-1 Dry-Type Sprinklers and the branch line. Failure to do so may result in pipe freezing and water damage. NOTICE Do not install the Series DS­1 Dry­Type Sprinkler into any other type fitting. Failure to use the appropriate fitting may result in one of the following: • failure of the sprinkler to operate properly due to formation of ice over the inlet Plug or binding of the Inlet Plug • insufficient engagement of the Inlet pipe threads with consequent leakage Drainage In accordance with the minimum requirements of the NATIONAL FIRE PROTECTION ASSOCIATION for dry pipe sprinkler systems, branch, cross, and feed-main piping connected to Dry Sprinklers and subject to freezing tem- peratures must be pitched for proper drainage. Exposure Length When using Dry Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use TFP510 Page 6 of 10 RECESS WRENCH FLAT WRENCH WITH SPRINKLER ENGAGEMENT IN TO ENSURE WRENCHING AREA PUSH WRENCH SIDE OUTLET PLUGGED TO WET SYSTEM FITTING (SEE DESIGN CRITERIA SECTION) SPRINKLERDSB-2 INTENDED FOR FREEZER STRUCTURES HEATED AREA RUN OUTLET PLUGGED TO DRY SYSTEM DSB-2 INTENDED FOR FREEZER STRUCTURES FITTING (SEE DESIGN CRITERIA SECTION) SPRINKLER AREA SUBJECT TO FREEZING INSULATED FREEZER STRUCTURE STRAP TIES (ENDS ON OPPOSING SIDES OF BOOT) ADHESIVE DS-1 SHOWN WITH STANDARD ESCUTCHEON 1-3/4" DIA. (44,5 mm) CLEARANCE HOLE DSB-2 BOOT (SEE DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING LENGTH EXPOSURE DSB-2 INTENDED FOR FREEZER STRUCTURES HEATED AREA INSULATED FREEZER STRUCTURE STRAP TIES (ENDS ON OPPOSING SIDES OF BOOT) ADHESIVE DS-1 SHOWN WITH STANDARD ESCUTCHEON 1-3/4" DIA. (44,5 mm) CLEARANCE HOLE DSB-2 BOOT FIGURE 16 W-TYPE 7 SPRINKLER WRENCH FIGURE 12 SPRINKLER FITTING HEATED AREA FIGURE 15 MODEL DSB-2 SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY SPRINKLER FIGURE 13 SPRINKLER FITTING UNHEATED AREA FIGURE 11 EXPOSURE LENGTH FIGURE 14 MODEL DSB-2 SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY SPRINKLER TFP510 Page 7 of 10 Ambient Temperature Exposed to Discharge End of Sprinkler Temperatures for Heated Area1 40°F (4°C) 50°F (10°C) 60°F (16°C) Minimum Exposed Barrel Length2 , in. (mm) 40°F (4°C)0 0 0 30°F (-1°C)0 0 0 20°F (-7°C) 4 (100)0 0 10°F (-12°C) 8 (200) 1 (25)0 0°F (-18°C) 12 (305) 3 (75)0 -10°F (-23°C) 14 (355) 4 (100) 1 (25) -20°F (-29°C) 14 (355) 6 (150) 3 (75) -30°F (-34°C) 16 (405) 8 (200) 4 (100) -40°F (-40°C) 18 (455) 8 (200) 4 (100) -50°F (-46°C) 20 (510) 10 (255) 6 (150) -60°F (-51°C) 20 (510) 10 (255) 6 (150) Notes: 1. For protected area temperatures that occur between values listed above, use the next cooler temperature. 2. These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). TABLE C EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS MINIMUM RECOMMENDED LENGTHS meet the requirements of the Design Criteria section. See the Design Crite- ria section for other important require- ments regarding piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) rating to 1/8 in. (3,2 mm) for the 286°F (141°C) rating. • A leak-tight 3/4 in. NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 10 to 20 lb-ft (13,4 to 26,8 N·m). • A leak-tight 1 in. NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 20 to 30 lb-ft (26,8 to 40,2 N·m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install pendent sprinklers only in the pendent position, and install upright sprinklers only in the upright position. The deflector of a pendent or upright sprin kler must be parallel to the ceiling. Install horizontal sidewall sprinklers in the horizontal position with their cen- terline of waterway perpen dicular to the back wall and parallel to the ceiling. Ensure the word “TOP” on the De flector faces the ceiling. Step 2. With a non-hardening pipe- thread sealant such as TEFLON tape applied to the Inlet threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Wrench-tighten the sprinkler using either: • a pipe wrench on the Inlet Band or the Casing, see Figures 1 and 2 • the W-Type 7 Sprinkler Wrench on the Wrench Flat, see Figure 16 Apply the Wrench Recess of the W-Type 7 Sprinkler Wrench to the Wrench Flat. build-up can occur that might damage the dry-type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB-2 Dry Sprin- kler Boot, described in Technical Data Sheet TFP591 and shown in Figures 14 and 15, can provide the recommended seal. Installation The TYCO Series DS-1 Dry-Type Sprin- klers, 5.6K Pendent, Upright, and Hori- zontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage must be installed in accordance with this section. General Instructions The Series DS-1 Dry-Type Sprinklers must only be installed in fittings that Table C to determine a sprinkler’s appropriate exposed barrel length to prevent water from freezing in the con- necting pipes due to conduction. The exposed barrel length measurement must be taken from the face of the sprinkler fitting to the surface of the structure or insulation that is exposed to the heated area. See Figure 11 for an example. Clearance Space In accordance with NFPA 13, when connecting an area subject to freez- ing and an area containing a wet pipe sprinkler system, the clearance space around the sprinkler barrel of Dry-Type Sprinklers must be sealed. Due to temperature differences between two areas, the potential for the formation of condensation in the sprinkler and sub- sequent ice build-up is increased. If this condensation is not controlled, ice TFP510 Page 8 of 10 Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. See the Installation Section. The owner is responsible for the in spection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTEC TION ASSOCIATION, such as NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Note: If sprinkler removal becomes neces- sary, remove the sprinkler using the same wrenching method noted above. Sprinkler removal is easier when a non-hardening sealant was used and torque guidelines were followed. After removal, inspect the sprinkler for damage. Step 4. After installing the ceiling or wall and applying a ceiling finish, slide on the outer piece of the escutcheon until it comes in contact with the ceiling or wall. Do not lift the ceiling panel out of its normal position. When using the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling or wall). Then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance The TYCO Series DS-1 Dry-Type Sprin- klers, 5.6K Pendent, Upright, and Hori- zontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an es cutcheon, which is used to cover a clearance hole, can delay the time to sprinkler operation in a fire situation. A Vent Hole is provided in the Bulb Seat (see Figures 1 and 2) to indicate if the Dry-Type Sprinkler is remaining dry. Evi dence of leakage from the Vent Hole indicates potential leakage past the Inlet seal and the need to remove the sprinkler to determine the cause of leakage for example, an improper installation or an ice plug. Close the fire protection system control valve and drain the system before removing the sprinkler. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). DS-1 Dry-Type Sprinklers When ordering TYCO Series DS-1 Dry-Type Sprinklers, 5.6K Pendent, Upright, and Horizontal Sidewall, Quick Response (3 mm bulb) and Stan- dard Coverage, specify the following information: • SIN: Pendent – TY3935 or TY3235 Sidewall – TY3735 or TY3335 Upright – TY3135 • 5.6 K-factor • Deflector Style: Upright, Pendent, or Horizontal Sidewall • Quick Response, Standard Cover- age, Dry-Type Sprinkler • Order Length: Dry-Type Sprinklers are furnished based upon Order Length as measured per Figures 3 through 10. After taking the measure- ment, round it to the nearest 1/4 in. increment. • Inlet Connections: 3/4 in. NPT, 1 in. NPT, or ISO 7-R 1 • Temperature Rating • Sprinkler Finish • Escutcheon Style and Finish, as applicable • Part Number (P/N) from Table D The Upright Sprinkler without an Escutcheon (TY3135) is available in 1 in. NPT only. Part Numbers are for 3/4 in. and 1 in. NPT standard order sprin- klers. Orders for all other sprinkler assemblies must be accompanied by a complete description. Refer to the Price List for a complete listing of Part Numbers. Sprinkler Wrench Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Sprinkler Boot Specify: Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002 This Part Number includes one (1) Boot, two (2) Strap Ties, and 1/3 oz of Adhesive (a sufficient quantity for installing one boot). TFP510 Page 9 of 10 SAMPLE ORDER LENGTHS2 055 5.50 in. 082 8.25 in. 180 18.00 in. 187 18.75 in. 372 37.25 in. 480 48.00 in. TEMPERATURE RATINGS 0 135°F (57°C) 1 155°F (68°C) 2 175°F (79°C) 3 200°F (93°C) 4 286°F (141°C) SPRINKLER FINISH ESCUTCHEON FINISH1 0 CHROME PLATED SIGNAL WHITE (RAL9003) 1 NATURAL BRASS SIGNAL WHITE (RAL9003) 2 NATURAL BRASS BRASS PLATED 4 SIGNAL WHITE (RAL9003) SIGNAL WHITE (RAL9003) 8 CHROME PLATED STAINLESS STEEL 9 CHROME PLATED CHROME PLATED SIN 01 Pendent with Standard Escutcheon (3/4 in. NPT) TY3935 (Figure 3) 02 Pendent with Deep Escutcheon (3/4 in. NPT) TY3935 (Figure 5) 03 Pendent with Recessed Escutcheon (3/4 in. NPT) TY3935 (Figure 4) 04 Pendent without Escutcheon (3/4 in. NPT) TY3935 (Figure 6) 05 Sidewall with Standard Escutcheon (3/4 in. NPT) TY3735 (Figure 8) 06 Sidewall with Deep Escutcheon (3/4 in. NPT) TY3735 (Figure 9) 07 Sidewall without Escutcheon (3/4 in. NPT) TY3735 (Figure 10) 36 Pendent with Standard Escutcheon (1 in. NPT) TY3235 (Figure 3 ) 33 Pendent with Deep Escutcheon (1 in. NPT) TY3235 (Figure 5 ) 37 Pendent with Recessed Escutcheon (1 in. NPT) TY3235 (Figure 4 ) 32 Pendent without Escutcheon (1 in. NPT) TY3235 (Figure 6 ) 34 Sidewall with Standard Escutcheon (1 in. NPT) TY3335 (Figure 8 ) 43 Sidewall with Deep Escutcheon (1 in. NPT) TY3335 (Figure 9 ) 44 Sidewall without Escutcheon (1 in. NPT) TY3335 (Figure 10 ) 38 Upright without Escutcheon (1 in. NPT) TY3135 (Figure 7) TABLE D SERIES DS-1 DRY-TYPE SPRINKLERS PART NUMBER SELECTION P/N* 60 – XXX – X – XXX Notes: 1. Escutcheon Finish applies to sprinklers provided with escutcheons. 2. Dry-Type Sprinklers are furnished based upon “Order Length” as measured per Figures 3 through 10, as applicable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 in. increment. * Use Prefix “I” for ISO 7-R 1 Connection (for example, I-60-360-4-055). TFP510 Page 10 of 10 NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; TEFLON is a registered trademark of DuPont 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 © 2019 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org July 20, 2021 Alternative Fire Protection Services 28701 Highway 74 Lake Elsinore, CA 92532 Re: TI Fire Sprinkler Plan Review – GROCERY OUTLET FSS2021-0155 / 50929 WASHINGTON ST #2, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. The following inspections/tests are required to be witnessed by the Office of the Fire Marshal staff: 1) Overhead Rough: All installed/relocated piping must be visible. 2) Final inspection: All trim is in place, 5-Year certification is current. New/added heads shall be included in the spare head box compliment. *Water-flow signal test may be performed during the Final Inspection. All persons performing work on the automatic fire sprinkler system shall be Certified Sprinkler Fitters or Registered with the State Fire Marshal for Apprentice or Trainee classification. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 50929 WASHINGTON STREET #2 PERMIT#: FSS2021-0155 DATE ISSUED: 07/20/2021 DESCRIPTION: GROCERY OUTLET TI CONTRACTOR: ALTERNATIVE FIRE PROTECTION SERVICES HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. 1 Hetrick, Kohl@CALFIRE From:Hetrick, Kohl@CALFIRE Sent:Tuesday, July 20, 2021 8:26 AM To:Bryan W. Geer Cc:Cooley, Sonia@CALFIRE Subject:FSS2021-0155 - ALTERNATIVE FIRE PROTECTION SERVICES - NOTICE OF VIOLATION Attachments:FSS2021-0155 - PERMIT DETAILS.pdf; ADMIN CITE #16-2145.pdf; CCR Title 19 Ch 5.5 Fire Sprinkler Fitter Certification.pdf Mr. Bryan Geer, After investigating concerns of modification work of an existing Fire Sprinkler System being performed at 50929 Washington St. - #2, La Quinta, CA 92253; and the resulting information discovered – I am issuing a Notice of Violation for (1) Performing work prior to permit issuance (CFC 105.1.1 / 105.7), & (2) Work performed on Fire Sprinkler System by individual(s) not possessing a valid State Fire Marshal – Sprinkler Fitter Certification. NOTICE OF VIOLATION This “Notice of Violation” is being provided in application to CA Health & Safety Code, Title 19, Ch 5.5 Automatic Fire Extinguishing Systems Certification, Article 4. Enforcement, § 927. Violations. The SFM, SFM Designee or AHJ is authorized to inspect project worksites where work on fire protection systems is being performed to ensure that persons performing the work possess valid certifications or registrations as required by this Chapter. The SFM, SFM Designee or AHJ is authorized to require persons performing work to provide proof of applicable certification or registration card. Any person who cannot show proof of certification or registration to the SFM, SFM Designee or AHJ shall be subject to Sections 928 through 932. It was observed that, and by your own admission, Alternative Fire Protection Services (CSLB: 941639) – You yourself had performed install/modification work and in violation of the following: H&S § 925. General Provisions. a) No person shall engage in the installation of water-based fire protection systems as defined in Section 924.12 without first being certified or registered in accordance with these regulations and have obtained a certification or registration card issued by the Office of the State Fire Marshal (OSFM). An Apprentice or Trainee shall become registered in accordance with the provisions in Article 5. H&S § 934. Employer Responsibility. Every properly licensed contractor performing installation of water-based fire protection systems shall ensure all fire sprinkler fitters under their employment are certified or registered. The licensed contractor shall notify the Office of the State Fire Marshal in writing within seventy-two (72) hours from the date of hire of an employee's status as a trainee, apprentice or certificate holder. Pending the review and approval of the documents submitted for Fire Sprinkler TI permit # FSS2021-0155, modifications or improvements in line with the scope of the permit shall only be performed by currently certified Sprinkler Fitters under your employment. This Notice of Violation includes a 1st Offense Administrative Citation authorized by the La Quinta Municipal Code. The Administrative Citation of $100.00 and a copy of this emailed Notice of Violation will be certified mailed to Alternative Fire Protection Services – 28701 Hwy 74, Lake Elsinore, CA 92532. Let me know if you have any questions. 2 KOHL HETRICK Fire Safety Specialist / Office of the Fire Marshal Cal Fire/Riverside County Fire Department City of La Quinta CAL FIRE/Riverside County Fire Department Desk: 760-777-7074 | Mobile: 760-409-5109 Inspection Hotline: 760-777-7131 78495 Calle Tampico, La Quinta, CA 92253 kohl.hetrick@fire.ca.gov | www.rvcfire.org Sch: Mon-Thurs Leadership, Competence, Integrity, Safety, Customer Service The Office of the County Fire Marshal is committed to facilitating fire and life safety solutions by empowering its employees to serve our community through innovation and partnership.