Loading...
FSS2021-0184ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 (760)625-5908 JCFIREPROTECTION@V ERIZON.NET CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL AARON HICKSON 8/2/2021 8/2/2021 EMAIL REQUESTING DOCUMENTS FOR REVIEW TELEPHONE CALL KOHL HETRICK 8/16/2021 8/16/2021 Spoke with Javier, general contractor failed to mention the work also associated on the upper level. I will hold of on completing the review to give Javier a couple of days to get the plans updated to reflect this additional detail. TELEPHONE CALL KOHL HETRICK 8/23/2021 8/23/2021 Javier advised that he has completed the document update and will be emailing to add to the plan review submittals CONDITIONS Description: ADJUSTING SPRINKLER COVERAGE - BCOM2021-0025 Type: FIRE SPRINKLER (WEB)Subtype: TENANT IMPROVEMENT Status: ISSUED Applied: 8/2/2021 ECON Parcel No: 658190003 Site Address: 77750 AVENUE 50 LA QUINTA,CA 92253 Approved: 8/30/2021 KHET Subdivision: Block: Lot: Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $4,000.00 Occupancy Type: Construction Type: Expired: 2/26/2022 JOD No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Thursday, March 02, 2023 11:36:15 AM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0184 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL CONTRACTOR J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 (760)625-5908 JCFIREPROTECTION@V ERIZON.NET OWNER LA QUINTA COUNTRY CLUB 77750 avenue 50 la quinta ca 92253 (760)625-5908 cjohnson@pgawest.co m INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD HYRO KHET 9/13/2021 9/13/2021 APPROVED FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS 101-0000-42420 0 $161.00 $161.00 8/30/21 WEB9156 632211973 01 CREDIT 996335 ECON FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS PC 101-0000-42420 0 $242.00 $242.00 8/30/21 WEB9156 632211973 01 CREDIT 996335 ECON Total Paid for FIRE FEES: $403.00 $403.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 8/30/21 WEB9156 632211973 01 CREDIT 996335 ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 8/30/21 WEB9156 632211973 01 CREDIT 996335 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$418.00 $418.00 Printed: Thursday, March 02, 2023 11:36:15 AM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0184 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 8/2/2021 EtrakitContractor 1ST SUBMITTAL PLANS La Quinta C.C Clubhouse Fire Plan .pdf 1 BOND INFORMATION OVERHEAD ROUGH PIPING KHET 9/13/2021 9/13/2021 APPROVED W/EXCEPTIO N SEE NOTES ADD ADDITIONAL SPARE HEAD BOX WITH COMPLIMENT OF CONCEALED HEADS, ESCUTCHEONS AND APPROPRIATE HEAD WRENCH. FIRE FINAL**LIN 1/25/2022 1/25/2022 DISAPPROVE D SEE NOTES 012522 - Conducted Final Inspection with Javier of JC Fire. I observed that the plans he provided on site did not match the area being inspected (lower level only - gym, salon and men's locker room). Javier and the site rep both indicated the plans reflect the site before demo and remodel. Sprinkler heads are showing in the wrong locations. I asked for a revised set of plans before approval. Javier made notes on the plans and I took photos for the file. REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 8/2/2021 8/26/2021 8/30/2021 APPROVED SEE ATTACHMENTS JAVIER IS REDRAWING PLANS TO SHOW ONE ADDITIONAL LOCATION THAT IS BEING AFFECTED BY THE TI - MOVING DUE DATE TO NEXT WEEK TO GIVE HIM TIME TO REPLACE THE PLANS. 1ST PERMIT TECH (1 DAY) AARON HICKSON 8/2/2021 8/3/2021 8/2/2021 COMPLETE PARENT PROJECTS Printed: Thursday, March 02, 2023 11:36:15 AM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0184 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 8/2/2021 EtrakitContractor 1ST SUBMITTAL APPLICATION FIRE APPLICATION SEPTEMBER 2019 FEE UPDATE REVISED 3 .pdf 1 DOC 8/2/2021 EtrakitContractor 1ST SUBMITTAL PIPES SCH 10 AND 40 copy.pdf 1 DOC 8/2/2021 EtrakitContractor 1ST SUBMITTAL FITTINGS SCI Ductile Iron Threaded Fittings copy copy.pdf 1 DOC 8/2/2021 EtrakitContractor 1ST SUBMITTAL ALL THREAD ROD all thread rod copy.pdf 1 DOC 8/2/2021 EtrakitContractor 1ST SUBMITTAL ADJUSTABLE HANGERS rings copy.pdf 1 DOC 8/2/2021 EtrakitContractor 1ST SUBMITTAL SAMMYS CATALOG Sammys-Catalog-2012 copy.pdf 1 DOC 8/2/2021 EtrakitContractor 1ST SUBMITTAL BRANCH TREE 5599_ST-SUB- FIGMT30.pdf 1 DOC 8/2/2021 EtrakitContractor 1ST SUBMITTAL SPRINKLER VK463 vk462 k5.6.pdf 1 DOC 1/27/2022 Etrakit Contractor AS BUILT AS BUILT FSS2021- 0184.pdf 1 DOC 8/30/2021 KOHL HETRICK FSS2021-0184 - APPROVED PLANS.pdf FSS2021-0184 - APPROVED PLANS.pdf 1 DOC 8/30/2021 KOHL HETRICK FSS2021-0184 - COA AND JOB CARD.pdf FSS2021-0184 - COA AND JOB CARD.pdf 1 PHOTO 1/27/2022 LUCERO INIGUEZ 20220125_113046.jpg 20220125_113046.jpg 0 PHOTO 1/27/2022 LUCERO INIGUEZ 20220125_113050.jpg 20220125_113050.jpg 0 PHOTO 1/27/2022 LUCERO INIGUEZ 20220125_113054.jpg 20220125_113054.jpg 0 PHOTO 1/27/2022 LUCERO INIGUEZ 20220125_113056.jpg 20220125_113056.jpg 0 Printed: Thursday, March 02, 2023 11:36:15 AM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0184 VK462CONCEALEDWHITE33FP1APPROVEDRiverside County Fire DepartmentLa Quinta Office of the Fire MarshalBy:FIRE SAFETY SPECIALIST08/30/2021 2:36:35 PMThe approval of plans and specifications does notpermit the violation, deletion, omission or faultyinstallation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remainaccessible and exposed for inspection purposesuntil approved by the Fire Department.PERMIT # -FSS2021-0184Kohl HetrickReason: I am approving this documentContact Info: 760-409-5109Date: 2021.08.30 14:37:41-07'00'4-63-63-63-61-01-00-60-64-01.1.1.1.1.1.1.= AS BUILT AREAS AS BUILT Schedule 10 and Schedule 40 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Bull Moose Tube’s Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot-dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. All Schedule 10 and Schedule 40 pipe has a pressure rating of 300 PSI. Schedule 10 Pipe Nominal Pipe Size (in) Nominal O.D. (in) Nominal I.D. (in) Weight/Ft Bundle Size 1 1.315 1.097 1.41 lbs/ft 91 1 1/4 1.660 1.442 1.81 lbs/ft 61 1 1/2 1.900 1.682 2.09 lbs/ft 61 2 2.375 2.157 2.64 lbs/ft 37 2 1/2 2.875 2.635 3.53 lbs/ft 30 3 3.500 3.260 4.34 lbs/ft 19 4 4.500 4.260 5.62 lbs/ft 19 Schedule 40 Pipe Nominal Pipe Size (in) Nominal O.D. (in) Nominal I.D. (in) Weight/Ft Bundle Size 1 1.315 1.049 1.68 lbs/ft 70 1 1/4 1.660 1.380 2.27 lbs/ft 51 1 1/2 1.900 1.610 2.72 lbs/ft 44 2 2.375 2.067 3.66 lbs/ft 30 2 1/2 2.875 2.468 5.80 lbs/ft 30 3 3.500 3.068 7.58 lbs/ft 19 4 4.500 4.026 10.80 lbs/ft 19 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer’s instructions for the specific fitting used. A company 1819 Clarkson Road Chesterfield, MO 63017 (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com e-mail: sales@bullmoosetube.com For additional information, contact your salesperson today at (800) 325-4467 or (636) 537-2600 in the USA, or from Canada call (800) 882-4666 All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 12/09 FP-10.16 PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: The MT-30 mechanical tee serves the same function as the MT-1 and MT-8, but uses a steel electro-plated u-bolt to save space and for easier installation in tight places.The MT-30 is ideal for direct connections with sprinkler heads and drop nipples. The MT-90 is the BSPT equivalent. For the latest UL/ULC listed, LPCB, VdS and FM Approved pressure ratings versus pipe schedule, see www.anvilintl.com or contact your local Anvil Representative. MATERIAL SPECIFICATIONS HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 U-BOLT & NUTS: U-bolt is carbon steel SAE J429 Gr. 2, zinc plated complete with hex flanged lock nuts conforming to ASTM A-563 Gr. A or B of SAE J995 Gr. 2. THREADS: NPT per ANSI/ASME B1.20.1. COATINGS: q Zinc Electroplated q Other available options: Example: RAL3000 or RAL9000 Series GASKETS: Materials Properties as designated in accordance with ASTM D-2000. q Grade “E” EPDM (Green color code) -40°F to 230°F (Ser vice Temperature Range)(-40°C to 110°C) Recommended for water ser vice, diluted acids, alkalies solutions, oil-free air and many chemical services not involving hydrocarbons, oils or gases. NOT FOR USE WITH HYDROCARBONS. FIG. MT-30 Threaded Mechanical Branch Tee For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. MT-30 THREADED MECHANICAL BRANCH TEE Nominal Size O.D. Hole Dimensions Max. Working Pressures Dimensions Approx. Wt. Ea.Min. Diameter Max. Diameter A B C TTake-out In./DN(mm) In./mm In./mm In./mm PSI/bar In./mm In./mm In./mm In./mm Lbs./Kg 11⁄4 x 1⁄2 1.660 x 0.840 1 3⁄16 15⁄16 300 2 1⁄8 31⁄2 21⁄4 15⁄8 0.8 32 x 12 42.4 x 21.3 30 33 20.7 54 89 57.2 42 0.4 11⁄4 x 3⁄4 1.660 x 1.050 1 3⁄16 15⁄16 300 2 1⁄8 31⁄2 21⁄4 15⁄8 0.8 32 x 19 42.4 x 26.7 30 33 20.7 54 89 57.2 42 0.4 11⁄4 x 1 1.660 x 1.315 1 3⁄16 15⁄16 300 2 1⁄4 31⁄2 21⁄4 15⁄8 1.1 32 x 25 42.4 x 33.7 30 33 20.7 58 89 57.2 41 0.5 11⁄2 x 1⁄2 1.900 x 0.840 1 3⁄16 15⁄16 300 2 1⁄4 31⁄2 21⁄4 13⁄4 0.8 40 x 12 48.3 x 21.3 30 33 20.7 57 89 57.2 48 0.4 11⁄2 x 3⁄4 1.900 x 1.050 1 3⁄16 15⁄16 300 2 1⁄4 31⁄2 21⁄4 13⁄4 0.9 40 x 19 48.3 x 26.7 30 33 20.7 57 89 57.2 48 0.4 11⁄2 x 1 1.900 x 1.315 1 3⁄16 15⁄16 300 2 3⁄8 31⁄2 21⁄4 13⁄4 1.1 40 x 25 48.3 x 33.7 30 33 20.7 61 89 57.2 48 0.5 2 x 1⁄2 2.375 x 0.840 1 3⁄16 15⁄16 300 2 1⁄2 33⁄4 21⁄4 2 0.9 50 x 12 60.3 x 21.3 30 33 20.7 64 95 57.2 51 0.4 2 x 3⁄4 2.375 x 1.050 1 3⁄16 15⁄16 300 2 1⁄2 33⁄4 21⁄4 2 0.9 50 x 19 60.3 x 26.7 30 33 20.7 64 95 57.2 51 0.4 2 x 1 2.375 x 1.315 1 3⁄16 15⁄16 300 2 5⁄8 33⁄4 21⁄4 2 1.1 50 x 25 60.3 x 33.7 30 33 20.7 67 95 57.2 50 0.5 21⁄2 x 1⁄2 2.875 x 0.840 1 3⁄16 15⁄16 300 2 3⁄4 41⁄4 21⁄4 21⁄4 0.9 65 x 12 73.0 x 21.3 30 33 20.7 70 108 57.2 57 0.4 21⁄2 x 3⁄4 2.875 x 1.050 1 3⁄16 15⁄16 300 2 3⁄4 41⁄4 21⁄4 21⁄4 0.9 65 x 19 73.0 x 26.7 30 33 20.7 70 108 57.2 57 0.4 21⁄2 x 1 2.875 x 1.315 1 3⁄16 15⁄16 300 2 7⁄8 41⁄4 21⁄4 21⁄4 1.1 65 x 25 73.0 x 33.7 30 33 20.7 73 108 57.2 56 0.5 For dry pipe systems and freezer applications lubrication of the gasket is required, Gruvlok® Xtreme™ Lubricant is required. BSP equivalent is available as a MT-90. s – Working Pressure Ratings are for reference only and based on Sch. 10 and Sch. 40 pipe. For the latest UL/ULC, FM, VdS and LPCB pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Note: Tighten nuts alternately to a recommended torque of 18-22 ft.-lbs. (25-30 Nm) on pipe wall less than schedule 10 (Din 2440) or 23-27 ft.-lbs. (31-37 Nm) on pipe walls schedule 10 (DIN 2440) and above. FIG. MT-30 Threaded Mechanical Branch Tee FP-10.16 FP-10.16 FIG. MT-30 & MT-90 Threaded Mechanical Branch Tees 1 Alignment Align the gasket and fitting above the 1.19" (30mm) pipe hole. Specified Bolt Torque 2Housing Assembly Attach the U-bolt from the other side and fasten the nuts finger tight. Step 1 Step 2 Step 3 3Tighten Nuts Making sure the fitting is properly located over the pipe hole, use a 9/16" (14 mm) wrench to tighten the nuts alternatively to a recommended torque of 18-22 ft.-lbs. (25-30 Nm) on pipe wall less than schedule 10 (DIN 2440) or 23-27 ft.-lbs. (31-37 Nm) on pipe walls schedule 10 (DIN 2440) and above. BRANCH SIZE HOLE SAW SIZE EQUIVALENT PIPE LENGTH Inches (mm)Inches +1/8, -0 (mm +3, -0)(see note) 1 25 1.19 30.23 5 1.52 Note: Flow Data is expressed as Feet/Meters of Schedule 40 steel outlet pipe with a "Hazen-Williams coefficient of friction value of 120". Specified bolt torque is for the u-bolt used on SPF® threaded mechanical branches. The nuts must be tightened alternately and evenly until fully tightened. Caution: Proper torquing of mechanical branch u-bolt is required to obtain specified performance. Over torquing the u-bolt may result in damage to the pipe and/or casting which could result in pipe joint separation. Under torquing the u-bolt may result in lower pressure retention capabilities, lower bend load capabilities, joint leakage and pipe joint separation. Pipe joint separation may result in significant property damage and serious injury. MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.06.26 Rev 20.3 Page 1 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTIONViking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired.The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile cover assembly that provides up to ½” (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “The “push-on” and “thread-on” designs of the concealed cover plate assemblies allow easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive environments and is listed and approved as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 VdS Approved: Certificate G4080021 LPCB Approved: Ref. No. 096e/12 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032 China Approval: Approved according to China GB Standard Refer to the Approval Charts and Design Criteria listing and approval requirements that must be followed. 3. TECHNICAL DATA Specifications:Available since 2006.Minimum Operating Pressure: 7 psi (0.5 bar)*Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating “250” stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar)Thread size: 1/2” (15 mm) NPTNominal K-Factor: 5.6 U.S. (80.6 metric**)Glass-bulb fluid temperature rated to -65°F (-55°C)Patents Pending * cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). ** Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards:Sprinkler Body: Brass UNS-C84400Deflector: Copper UNS-C19500 for Sprinkler; Phosphor Bronze UNS-C51000 for Sprinkler VK463Deflector Pins: Stainless Steel AlloyBulb: Glass, nominal 3 mm diameterPip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400Button: Brass UNS-C36000 Screws: 18-8 Stainless SteelBelleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE TapeYoke: Phosphor Bronze UNS-C51000Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials:Cover: Copper UNS-C11000 or Stainless Steel UNS-S30400Base: Brass UNS-C26000 or UNS-C26800Springs: Nickel AlloySolder: Eutectic Ordering Information: The sprinkler and cover plate must be ordered separately. Refer to Tables 1 and 2. Replaces Form No. F_103005 Rev 20.2 (Added cover plate options.) MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.06.26 Rev 20.3 Page 2 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 4. INSTALLATIONRefer to appropriate NFPA Installation Standards. 5. OPERATIONDuring fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCERefer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITYViking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEEFor details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: SPRINKLER ORDERING INFORMATION Instructions: (1) Select a Sprinkler Base Part Number (2) Add the suffix for the desired Finish (3) Add the suffix for the desired Sprinkler Temperature Rating (4) Order a cover plate (refer to Table 2) Example: 13503AE = 200 °F (93 °C) Temperature Rated Sprinkler with a standard Brass finish. SIN Sprinkler Base Part Number8 Size 1: Finishes 2: Temperature Ratings NPT Inch BSPT mm Description Suffix1 Sprinkler Temperature Classification Nominal Rating Bulb Color Max. Ambient Ceiling Temperature2 Suffix VK462 13503 1/2 --Brass A Ordinary 155 °F (68 °C)Red 100 °F (38 °C)B VK462 213567,9 --15 ENT 3,4 JN Intermediate 175 °F (79 °C)Yellow 150 °F (65 °C)D VK463 13667 1/2 --Intermediate 200 °F (93 °C)Green 150 °F (65 °C)E Accessories Sprinkler Wrenches and tools (see Figure 1): A. Heavy Duty Part Number: 14047W/B5 (available since 2006) B. Head Cabinet Wrench Part Number: 140316 (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part Number: 1441210 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 1486710 (available since 2007) Sprinkler Cabinet:Holds up to 6 sprinklers: Part number 01731A (available since 1971). Footnotes 1. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. 2. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. UL Listed as corrosion resistant. 4. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. 5. Requires a ½” ratchet (not available from Viking). 6. Also optional for removal of the protective cap. Ideal for sprinkler cabinets. 7. Not available with ENT finish. See approval charts for more information. 8. See approval charts for more information. 9. Approved according to China GB Standard. 10. The installer tool is for push-on style cover plates only. MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.06.26 Rev 20.3 Page 3 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com TABLE 2: COVER PLATE ORDERING INFORMATION Instructions: (1) Select a Cover Plate Base Part Number (2) Add the suffix for the desired Finish (3) Add the suffix for the required Cover Plate Nominal Rating. Example: 23190MC/W = 165 °F (74 °C) Temperature Rated, 2-3/4” (70 mm) diameter, Thread-On style Round Cover Plate with a Painted White finish. 1: Select a Cover Plate Base Part Number3 2: Select a FinishThread-On Style Push-On Style Base Part Number Size Inch (mm)Type Base Part Number Size Inch (mm)Type Description Suffix5 23190 2-3/4 (70)Round 23447 2-3/4 (70)Round Polished Chrome F 23174 3-5/16 (84)Round 23463 3-5/16 (84)Round Brushed Chrome F-/B 23179 3-5/16 (84)Square 23482 3-5/16 (84)Square Bright Brass B 231934 2-3/4 (70)Stainless Steel Round 234554 2-3/4 (70)Stainless Steel Round Antique Brass B-/A Brushed Brass B-/B 231834 3-5/16 (84)Stainless Steel Round 234734 3-5/16 (84)Stainless Steel Round Brushed Copper E-/B Painted White M-/W 23174-/CR 3-5/16 (84)Clean Room 23463-/CR 3-5/16 (84)Clean Room Painted Ivory M-/I 23183CR4 3-5/16 (84) Stainless Steel Round Clean Room 23473CR4 3-5/16 (84) Stainless Steel Round Clean Room Painted Black M-/B 3: Temperature Rating Matrix1,2 Cover Plate Nominal Rating (Required) Temperature Classification Sprinkler Nominal Rating Sprinkler Maximum Ambient Ceiling Temperature2 Suffix UL: 135 °F (57 °C) FM: 139° F (59 °C)Ordinary 155 °F (68 °C)100 °F (38 °C)A 165 °F (74 °C)Intermediate 175 °F (79 °C)150 °F (65 °C)C 165 °F (74 °C)Intermediate 200 °F (93 °C)150 °F (65 °C)C Footnotes 1. The sprinkler temperature rating is stamped on the deflector. 2. Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 4. Stainless Steel versions are not available with any finishes or paint. 5. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.06.26 Rev 20.3 Page 4 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart 1 (UL) Mirage® Concealed Pendent Sprinklers VK462 and VK463 Sprinkler Base Part No.1 SIN Thread Size Nominal K-factor Maximum Water Working Pressure Listings and Approvals4 (Refer also to Design Criteria) NPT Inch BSPT mm U.S.metric2 cULus5 NYC VdS7 LPCB China Approval Standard Response Applications 13503A VK462 1/2”--5.6 80.6 175 psi (12 bar)----AY1, CZ1 AY1, BZ1 AY1, CZ18 -- 21356A12 VK462 --15 5.6 80.6 175 psi (12 bar)----------AY1, CZ1 Quick Response Applications 13503A VK462 1/2”15 5.6 80.6 175 psi (12 bar)AV1, BX1, AS2, BT2 AV1, BX16 -------- 13503JN11 VK462 1/2”15 5.6 80.6 175 psi (12 bar)AV1, BX1, AS2, BT2 AV1, BX16 -------- 21356A12 VK462 --15 5.6 80.6 175 psi (12 bar)AY1, CZ1 ---------- 13667A VK463 1/2”15 5.6 80.6 250 psi (17.2 bar)3 AV1, BX1 AV1, BX16 -------- 13667JN11 VK463 1/2”15 5.6 80.6 250 psi (17.2 bar)3 AV1, BX1 AV1, BX16 -------- Approved Sprinkler Temperature Rating Codes Approved Cover Plate Temperature Rating Codes Approved Cover Plate Finish Codes A = 155 °F (68 °C) B = 175 °F (79 °C) C = 200 °F (93 °C) S - 135 °F (57 °C) cover 23193, 23445 or 23183, 23473 (large diameter) T - 165 °F (74 °C) cover 23193, 23445 or 23183, 23473 (large diameter) V - 135 °F (57 °C) cover 23190, 23447, 23174, 23463 (large diameter), or 23179, 23482 (square cover plate) X - 165 °F (74 °C) cover 23190, 23447, or 23174, 23463 (large diameter) Y - 135 °F (57 °C) cover 23190, 23447 LPCB Approved as 139 °F (59 °C) Z - 165 °F (74 °C) cover 23190, 23447 1 - Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 2 - Stainless Steel Footnotes 1. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. The Water Working Pressure rating is stamped on the deflector. 4. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5. Listed by Underwriter’s Laboratories for use in the U.S. and Canada. 6. Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. 7. VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999 + A1:2001 + A2:2004 + A3:2006, Certificate G4080021. 8. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. 9. The 135/139 °F cover has an orange label. The 165 °F (74 °C) cover has a white label. 10. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. 11. cULus Listed as corrosion resistant. 12. Approved according to China GB Standard. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.06.26 Rev 20.3 Page 5 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA - UL (Also refer to Approval Chart 1) cULus Listing Requirements: Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. • For hazard occupancies up to and including Ordinary Hazard, Group II. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). • Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. • Minimum distance from walls is 4 in. (102 mm). • Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. • The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS Approval Requirements: a) The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. b) This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. c) Follow installation guidelines of current standards, CEA4001VdS and EN12845. These sprinklers can only be installed in LH and OH occupan- cies, except in OH4. NOTES: Due to the design the sprinkler type ‘Domed-CCP’ shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type ‘Domed-CCP’ shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: 1. Prepare the sprinkler key. 2. Remove the plastic cover. 3. Hold the sprinkler with the wrench and fasten it. 4. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Figure 1: Identification of Custom Paint for Concealed Covers Figure 2: Square Cover Assembly All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label.FACTORY APPLIE D C USTO M P A I NT COLOR MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.06.26 Rev 20.3 Page 6 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Approval Chart 2 (FM) Mirage® Standard Response Concealed Pendent Sprinkler VK462 Sprinkler Base Part No.1 SIN Thread Size Nominal K-Factor Maximum Water Working Pressure FM Approvals3 (Refer also to Design Criteria below.)NPT Inch BSPT mm U.S.metric2 13503A VK462 1/2”15 5.6 80.6 175 psi (12 bar)AW1, BX1, AY2, BZ2 21356A6 VK462 --15 5.6 80.6 175 psi (12 bar)AU1, CV1 Approved Sprinkler Temperature Rating Codes Approved Cover Plate Temperature Rating Codes Approved Cover Plate Finish Codes A - 155 °F (68 °C) B - 175 °F (79 °C) and 200 °F (93 °C) C - 200 °F (93 °C) U - 139 °F (59 °C) cover 23190, 23447 V - 165 °F (74 °C) cover 23190, 23447 W - 139 °F (59 °C) cover 23190, 23447, or 23174, 23463 (large diameter), or 23179, 23482 (square cover plate) X - 165 °F (74 °C) cover 23190, 23447, 23174, 23463 (large diameter), or 23179, 23482 (square cover plate) Y - 139 °F (59 °C) cover, 23183, 23473 or 23193, 23455 Z - 165 °F (74 °C) cover 23183, 23473 or 23193, 23455 1 - Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 2 - Stainless Steel Footnotes 1. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4. The 139 °F (59 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. 5. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. 6. Approved according to China GB Standard. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.06.26 Rev 20.3 Page 7 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins Sprinkler Wrench Part No. 14047W/B** ** A 1/2” ratchet is required (Not available from Viking) 2-1/4” (57 mm) diameter opening required in the ceiling. Step 2: Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Figure 3: Sprinkler Installation and Proper Wrench Usage NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Sprinkler wrench flat Sprinkler frame arms Figure 4: Sprinkler Dimensions and Cover Installation 1/2” (15 mm) NPT 2-3/16”(55 mm)2-9/16” (65 mm)Maximum 2-1/16” (52 mm)Minimum 2-3/4” (70 mm) or 3-5/16” (84 mm)NOTE: Upon sprinkler activation, the deflector descends to approximately 13/16” (21 mm) below the sprinkler body. Replaces Form No. F_103005 Rev 20.2 (Added cover plate options.) Ductile Iron Threaded Fittings Ductile Iron Threaded Fittings Ductile Iron Threaded Fittings TemperatureDegrees F Working Pressure, Non-Shock psigClass 300 Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 Specifications • branded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 psi WSP • Ductile iron castings conform to ASTM A536 • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 • All fittings are 100% air tested • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical & mechanical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 • ProPak™ Packaging SCI ProPak™ System SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com237 DUCTILE A A A A A A AA B Size in Part Number A in Packing Weight lbInnerMaster 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 1 35E 3010 1.50 40 80 0.5 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Size in Part Number A in B in Packing Weight lbInnerMaster 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 1-1/2 35F 3014 1.44 20 40 1.0 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35T 3004 1.13 80 160 0.3 3/4 35T 3006 1.31 30 60 0.5 1 35T 3010 1.50 25 50 0.7 1-1/4 35T 3012 1.75 10 20 1.1 1-1/2 35T 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 Fig. 35E 3 – 90° Elbow Fig. 35RE3 – 90° Reducing Elbow Fig. 35F 3 – 45° Elbow Fig. 35T 3 – Tee Ductile Iron Threaded Fittings - Class 300 UL/FM SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 238 DUCTILE A B AB C C Size in Part Number A in B in C in Packing Weight lbInnerMaster 3/4 x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 1 x 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 1 x 1/2 x 1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1 x 3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 1 x 3/4 x 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 1 x 3/4 x 1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4 x 3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2 x 3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2 x 3/4 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2 x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2 x 1 x 1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2 x 1 x 3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2 x 1 x 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1/2 x 1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2 x 1-1/4 x 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2 x 1-1/4 x 1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2 x 1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2 x 1-1/2 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2 x 1-1/2 x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 Size in Part Number A in B in C in Packing Weight lbInnerMaster 3/4 x 1 35BT3006010 1.45 1.45 1.37 30 60 0.6 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 1 x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 1-1/4 x 1 x 1-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1.2 1-1/4 x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2 x 2 35BT3014020 2.16 2.16 2.02 8 16 1.8 Fig. 35BT3 – Bull Head Tee Fig. 35RT3 – Reducing Tee Ductile Iron Threaded Fittings - Class 300 UL/FM SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com239 DUCTILE A A A AA B Size in Part Number A in Packing Weight lbInnerMaster 1 35U 3010 2.19 20 40 1.0 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 3.12 6 12 2.4 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Size in Part Number A in Packing Weight lbInnerMaster 1 x 1/2 35RC3010004 1.69 80 160 0.3 1 x 3/4 35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (not hex)35RC3020010 2.81 20 40 1.0 Size in Part Number A in B in Packing Weight lbInnerMaster 1 x 1/2 35HB3010004 1.06 1.40 180 360 0.2 1 x 3/4 35HB3010006 1.06 1.40 180 360 0.1 1-1/4 x 1 35HB3012010 1.19 1.80 90 180 0.2 1-1/2 x 1 35HB3014010 1.25 1.95 75 150 0.4 1-1/2 x 1-1/4 35HB3014012 1.25 1.95 75 150 0.3 2 x 1 35HB3020010 1.38 2.55 40 80 0.6 2 x 1-1/4 35HB3020012 1.38 2.55 40 80 0.6 2 x 1-1/2 35HB3020014 1.38 2.55 40 80 0.6 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35CP3 – Straight Coupling with Ribs Fig. 35RC3 – Hex Reducing Coupling Fig. 35HB3 – Hex Bushing Fig. 35SP3 – Square Head Plug Fig. 35U 3 – Union with Brass Seat Ductile Iron Threaded Fittings - Class 300 UL/FM SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 240 DUCTILE A A A A A A A B B Size in Part Number A in B in Packing Weight lbInnerMaster 1-1/4 x 1 35RX3012010 1.67 1.58 15 30 1.2 1-1/2 x 1 35RX3014010 1.80 1.65 12 24 1.4 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 Size in Part Number A in Packing Weight lbInnerMaster 1 35X 3010 1.50 20 40 0.9 1-1/4 35X 3012 1.75 12 24 1.4 1-1/2 35X 3014 1.94 8 16 1.8 2 35X 3020 2.25 6 12 2.8 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35C 3004 0.87 300 600 0.1 3/4 35C 3006 0.97 200 400 0.1 1 35C 3010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35X 3 – Cross Fig. 35RX3 – Reducing Cross Fig. 35C 3 – Cap Size in Part Number A in Packing Weight lbInnerMaster 3/8 35BC3003 0.75 100 200 0.3 1/2 35BC3004 0.75 80 160 0.5 Fig. 35BC3 – Beam Clamp A Ductile Iron Threaded Fittings - Class 300 UL/FM OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 91 www.tolco.com Revision 12/18/2008 Fig. 200 - “Trimline” Adjustable Band Hanger Fig. 200R (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. • (21⁄2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters’ Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By — Figure number and pipe size Note — Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31⁄8 25⁄8 400 11 3/4 3/8 8mm or 10mm 31⁄8 21⁄2 400 11 1 3/8 8mm or 10mm 33⁄8 25⁄8 400 12 11⁄4 3/8 8mm or 10mm 33⁄4 27⁄8 400 13 11⁄2 3/8 8mm or 10mm 37⁄8 27⁄8 400 14 2 3/8 8mm or 10mm 41⁄2 3 400 15 21⁄2 3/8 10mm 55⁄8 41⁄8 600 27 3 3/8 10mm 57⁄8 4 600 29 31⁄2 3/8 10mm 73⁄8 51⁄4 600 34 4 3/8 10mm 73⁄8 5 1000 35 5 1/2 12mm 91⁄8 61⁄4 1250 66 6 1/2 12mm 101⁄8 63⁄4 1250 73 8 1/2 12mm 131⁄8 83⁄4 1250 136 A B A B A B A B Fig. 200 1" - 2"Fig. 200 21⁄2" - 8" Fig. 200R 21⁄2" - 8"Fig. 200R 1/2" - 2" Sammys® for Wood .......................................................................................................................... 4 Sidewinder® for Wood ....................................................................................................................... 5 Sammys Swivel Head™ for Wood ......................................................................................................5 Sammys® for Steel ............................................................................................................................ 6 Sidewinder® for Steel ........................................................................................................................ 7 Sammys Swivel Head™ for Steel .......................................................................................................7 Sammy X-Press® ...............................................................................................................................8 Sammy X-Press Sidewinder™ ............................................................................................................8 Sammy X-Press Swivel™ ...................................................................................................................9 Sammy X-Press It® Installation Tool ..................................................................................................9 Sammys® for Concrete ................................................................................................................... 10 Sidewinder® for Concrete ................................................................................................................10 Sammys Swivel Head™ for Concrete ................................................................................................11 Concrete/Wood Installation Kit ........................................................................................................ 11 Sammys Toggle™ ............................................................................................................................ 12 Ceiling Screws .................................................................................................................................12 Dektite® Pipe Flashing .....................................................................................................................13 Speedy Pole Tool™.......................................................................................................................... 13 Spot Rite Level™ ..............................................................................................................................13 Approvals and Listings ....................................................................................................................14 Special Notes ..................................................................................................................................15 TABLE OF CONTENTS Warranty • Disclaimer of Warranty Proper fastener connection design takes in to account where and how fasteners are used. Allowance for special characteristics in materials, differences in materials, differences in types of materials being joined, unique or unusual environmental service or installation conditions and the safety factors required by anticipating normal or short term loading conditions must be considered. Due to possible differences in specifications, applications, and interpretation of results, purchasers and specifiers must make their own evaluation of the products, to determine the suitability of these products for intended use. All warranties of Buildex products, expressed or implied, including the warranties of merchantabilty and fitness for particular purposes are specifically excluded except for the following: Buildex will repair or replace any product which, within twelve months after sale by Buildex or its distributors, is found by Buildex to be defective in material or workmanship - normal wear and tear accepted. This is the sole warranty of Buildex and the sole remedy available to distributor or buyer. Buildex shall not be liable for any injury, loss or damage, direct, indirect, or consequential, arising out of the use of, or the inability to use, any Buildex product. For the most up to date information, visit www.itwbuildex.com 3 To find a distributor near you, call 800-BUILDEX INSTALLATION STEPS - VERTICAL INTO CONCRETE: 1. Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2” with a hammer/rotary hammer drill set on impact mode. 2. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). 3. Insert the CST screw into the nut driver. 4. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. 5. The concrete screw is ready to receive 1/4”, 3/8”, 1/2”, or metric all thread rod or bolt stock. (#14SW red nut driver used with 1/2” screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode — doing so will destroy the pullout factor of the screw. INSTALLATION STEPS - HORIZONTAL INTO CONCRETE: 1. Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2” with a hammer/ rotary hammer drill set on impact mode. 2. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14SW (red) nut driver (p/n 8114910) into the opposite end. 3. Insert the SWC screw into the nut driver. 4. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. 5. The SWC screw is ready to receive 1/4”, 3/8” or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode — doing so will destroy the pullout factor of the fastener. INSTALLATION INSTRUCTIONS FOR CONCRETE SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. INSTALLATION STEPS - VERTICAL INTO WOOD & STEEL: 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 2. Insert the SAMMYS® into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. 3. Push the face of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. 4. The SAMMYS is now ready to receive 1/4”, 3/8”, 1/2” or metric all thread rod, bolt stock. (The 1/2” requires the #14SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximumpullout in purlin steel. INSTALLATION STEPS - HORIZONTAL INTO WOOD & STEEL: 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 2. Insert the SAMMYS into the #14SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. 3. When the nut driver spins freely on the SAMMYS, stop the drill and remove. 4. The unit is now ready to receive 1/4”, 3/8”, M10, M8 or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. INSTALLATION INSTRUCTIONS FOR WOOD & STEEL 4 For the most up to date information, visit www.itwbuildex.com Wood Flooring Wood Joist Double Sheetrock Ceiling Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Box Qty Case Qty VERTICAL MOUNT 1/4"8002957 GST 100 1/4 x 1"210 (7/16” OSB) 670 (3/4” Ply)25 125 1/4"8003957 GST 200 1/4 x 2"1760 (Fir)25 125 3/8"8007957 GST 10 1/4 x 1"210 (7/16” OSB) 670 (3/4” Ply)300 25 125 3/8"8008957 GST 20 1/4 x 2"1760 (Fir)850 1475 25 125 3/8"8068925 GST 20-SS 1/4 x 2"1760 (Fir)850 25 125 3/8"8009925 GST 25-380 3/8 x 2-1/2"2113 (Fir)1500 25 125 3/8"8010957 GST 30 1/4 x 3"2060 (Fir)1500 1475 25 125 3/8"8069925 GST 30-SS 1/4 x 3"2060 (Fir)25 125 1/2"8013925 GST 2 1/4 x 2"1760 (Fir)25 125 1/2"8015925 GST 3 1/4 x 3"2275 (Fir)25 125 Not less than 2” nominal width (1-1/2”) Not less than 3” nominal thickness (2-1/2”) (depth or side of vertical member) #14 Black Nut Driver Part # 8113910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. #14 SW Red Nut Driver Part # 8114910 Composite / Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for GST 25-380 . Tool available on page 11. For vertical use - install in center of lower face. Minimum 2” embedment into base material for NFPA 13 compliance. • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation costs. • Manufactured in the U.S.A. SAMMYS® FOR WOOD Application Product Features Watch a video demonstration atwww.itwbuildex.com SAMMYS® FOR WOOD - Vertical Application MANUFACTURED U.S.A. 5 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETENot less than 2” nominal width (1-1/2”) up to 3-1/2” pipe; not less than 3” (2-1/2”) nominal width 4” & 5” pipe Minimum 2-1/2” from bottom for branch lines. Minimum 3” from bot- tom for main lines. Exception: This requirement shall not apply to 2” or thicker nailing strips resting on top of steel beams. Floor Joist Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) Box Qty Case Qty HORIZONTAL MOUNT 1/4"8019957 SWG 200 1/4 x 2"1725 (Fir)25 125 3/8"8020957 SWG 10 1/4 x 1"622 (Fir)300 25 125 3/8"8021957 SWG 20 1/4 x 2"1725 (Fir)1050 25 125 3/8"8073925 SWG 20-SS 1/4 x 2"1725 (Fir)850 25 125 3/8"*8022925 SWG 25-380 3/8 x 2-1/2"2249 (Fir)1500 25 125 3/8"8023925 SWG 30 1/4 x 3"1884 (Fir)25 125#14 SW Red Nut Driver Part # 8114910 • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation costs. • Manufactured in the U.S.A. Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thickness Box Qty Case Qty SWIVEL MOUNT 3/8"8139957 SH-GST 20 1/4 x 2"1257 (Fir)1050 1475 25 125 3/8"*8269957 SH-GST/CST 20 5/16 x 1-3/4” 1903 Dim. Lumber 1406 @ 45°off vertical Dim. Lumber 1500 850 @ 45°25 125 1/2”8303957 SH-GST/CST 2.0 5/16 x 1-3/4” 903 Dim. Lumber 1406 @ 45°off vertical Dim. Lumber 25 125 #14 Black Nut DriverPart # 8113910 • Eliminates distortion of threaded rod. • Accommodates up to 3 ½” x 12 pitch roof. • Allows 17° deflection from vertical. • Saves time from traditional methods. • Reduces installation costs. • Manufactured in the U.S.A. Application Product Features Application Product Features Composite / Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for Model SWG 25-380. Tool available on page 11. Watch a video demonstration atwww.itwbuildex.com SIDEWINDER® FOR WOOD - Horizontal Application SAMMYS SWIVEL HEAD™ FOR WOOD - Swivel Application #14 SH Orange Nut DriverPart # 8273910 * May require pre-drilling; consult joist manufacturer. * May require pre-drilling; consult joist manufacturer. 6 For the most up to date information, visit www.itwbuildex.com Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thick Max Thick Box Qty Case Qty VERTICAL MOUNT 1/4"8024957 DSTR 100 *1/4-20 x 1" TEKS 3 1510 (20 ga.).036"-20 ga 3/16"25 125 1/4"8025957 DST 100 1/4-14 x 1" TEKS 3 446 (20 ga.).036"-20 ga 3/16"25 125 1/4"8026957 DST 150 1/4-14 x 1-1/2" TEKS 3 970 (16 ga.).036"-20 ga 3/16"25 125 1/4"8027957 DST 200 1/4-14 x 2" TEKS 3 446 (20 ga.).036”-20 ga 3/16”25 125 1/4"8030957 TEK 500 12-24 x 1-1/2" TEKS 5 3125 (3/16").188”-3/16”1/2"25 125 3/8"8038957 DSTR 1 *1/4-20 x 1" TEKS 3 1510 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8037957 DSTR 1-1/2 *12-24 x 1-1/2" TEKS 5 1510 (3/16")1500 1475 .060”-16 ga.1/2"25 125 3/8"8039957 DSTR 516 *5/16-18 x 1-1/4" TEKS 3 2200 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8040957 DST 10 1/4-14 x 1" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8077925 DST 10-SS 1/4-14 x 1" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8041957 DST 15 1/4-14 x 1-1/2" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8078925 DST 15-SS 1/4-14 x 1-1/2" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8042957 DST 20 1/4-14 x 2” TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8044957 DST 30 1/4-14 x 3" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8045957 DST 516 5/16-18 x 1-1/4" TEKS 3 1500 (3/16")1500 1475 .125"-1/8"3/16"25 125 3/8"8046957 TEK 50 12-24 x 1-1/2" TEKS 5 3125 (3/16")1500 1475 .250”-1/4”1/2"25 125 1/2"8031925 DST 2.0 1/4-14 x 2" TEKS 3 446 (20 ga.) 970 (16 ga.).188"-3/16"1/4"25 125 1/2"8033925 DSTR 1.0 *1/4-20 x 1" TEKS 3 1510 (20 ga.).036"-20 ga 3/16"25 125 1/2"8034925 DSTR 5.16 *5/16-18 x 1-1/4" TEKS 3 2220 (20 ga.).036"-20 ga 3/16"25 125 1/2"8035925 DST 5.16 5/16-18 x 1-1/4" TEKS 3 1500 (3/16").125"-1/8"3/16”25 125 1/2"8036925 TEK 5.0 12-24 x 1-1/2" TEKS 5 3125 (3/16").188"-3/16"1/2"25 125 #14 Black Nut Driver Part # 8113910 #14 SW Red Nut Driver Part # 8114910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. • Made with Teks® self-drilling fasteners - no pre-drilling required. • Installs into steel range from 20 gauge – 1/2” thicknesses. • Saves time from traditional methods. • Reduces installation costs. • Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. • A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. • Manufactured in the U.S.A. SAMMYS® FOR STEEL Watch a video demonstration atwww.itwbuildex.com Application Product Features SAMMYS® FOR STEEL - Vertical Application *Includes retaining nut MANUFACTURED U.S.A. 7 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETEApprovals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thick Max Thick Box Qty Case Qty SWIVEL MOUNT 3/8"8137957 SH-DSTR 1*1/4-20 X 1” TEKS 3 3220 (3/16”)1500 1475 .035”3/16”25 125 3/8"8268957 SH-TEK 50 12-24 x 1-3/4" TEKS 5 2368 (1/2" steel Vertical) 1306 (45° off Vertical) 2281 (3/16” HSS) 1585 (3/16” HSS 45° off Vertical) 1500 (Vertical) 850 (45° off Vertical) 4" 2-1/2” 3/16"1/2"25 125 1/2”8270957 SH-TEK 5.0 12-24 x 1-3/4” TEKS 5 2368 (1/2” steel Vertical) 1306 (45° off Vertical) 2281 (3/16” HSS) 1585 (3/16” HSS 45° off Vertical) 3/16"1/2"25 125 #14 Black Nut DriverPart # 8113910 Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thickness Max Thickness Box Qty Case Qty HORIZONTAL MOUNT 1/4"8047957 SWD 100 1/4-14 x 1" TEKS 3 1477 (16 ga.).060"-16 ga 3/16"25 125 1/4"8049957 SWDR 100 *1/4-20 x 1" TEKS 3 1900 (20 ga.).036"-20 ga 3/16"25 125 3/8"8050957 SWD 10 1/4-14 x 1" TEKS 3 1477 (16 ga.).060"-16 ga 3/16"25 125 3/8"8080925 SWD 10-SS 1/4-14 x 1" TEKS 3 1477 (16 ga.).060"-16 ga 3/16"25 125 3/8"8052957 SWD 20 1/4-14 x 2" TEKS 3 1477 (16 ga.).060"-16 ga 3/16”25 125 3/8"8055957 SWDR 1 *1/4-20 x 1" TEKS 3 1900 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8054957 SWDR 1-1/2 *12-24 x 1-1/2" TEKS 5 2375 (3/16")1500 1475 .188"-3/16"1/2"25 125 3/8"8056957 SWDR 516 *5/16-18 x 1-1/4" TEKS 3 2480 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8057957 SWT 15 12-24 x 1-1/2" TEKS 5 2375 (3/16").188"-3/16"1/2"25 125 #14 SW Red Nut Driver Part # 8114910 *Includes retaining nut • Made with Teks® self-drilling fasteners - no pre-drilling required. • Installs into steel range from 20 gauge – 1/2” thicknesses. • A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. • Saves time from traditional methods. • Reduces installation costs. • Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. • Manufactured in the U.S.A. • Eliminates distortion of threaded rod in sloped roof applications. • Accommodates 3-1/2 x 12 pitch. • Installs into angled z-purlin; allows threaded rod to hang plumb. • Allows 17° deflection from vertical. • Manufactured in the U.S.A. *Does not comply with ROHS requirements / Includes retaining nut Application Product Features SAMMYS SWIVEL HEAD™ FOR STEEL - Swivel Application SIDEWINDER® FOR STEEL - Horizontal Application Application Product Features #14 SH Orange Nut DriverPart # 8273910 Watch a video demonstration atwww.itwbuildex.com Watch a video demonstration atwww.itwbuildex.com 8 For the most up to date information, visit www.itwbuildex.com SAMMY X-PRESS® - Vertical Application Approvals Rod Size Part Number Model Description Ultimate Pullout (lbs) UL Test Load (lbs) UL Min Thick FM Test Load (lbs) FM Min Thick Max Thick Box Qty Case Qty Application VERTICAL MOUNT 1/4"8181922 XP 200 Sammy X-Press 200 1146 (22 ga)185 (Luminaire) 250 (Luminaire) .027" .056”.125”25 125 Metal Deck 3/8"8150922 XP 20 Sammy X-Press 20 1146 (22 ga) 850 (2½" Pipe) 185 (Luminaire) 250 (Luminaire) 283 (Conduit & Cable) .027" .027” .056” .029” 940 (2" Pipe) 1475 (4” Pipe) .029” .104” .125”25 125 Metal Deck 3/8"8153922 XP 35 Sammy X-Press 35 1783 (16 ga) 1500 (4" Pipe) 185 (Luminaire) 250 (Luminaire) 416 (Conduit & Cable) .060” .029” .056” .059” 940 (2" Pipe) 1475 (4” Pipe) .029” .104”.125”25 125 Purlin 3/8"8150922 XP 20 Sammy X-Press 20 1146 (22 ga)850 (2½ Pipe) Pre-Pour Structural Concrete@ 3000 psi Post-Pour Range II LWC≤ 35 PCF (lbs/ft³) 25 125 Metal Deck (Pre-Pour) Metal Deck (Post-Pour) SAMMY X-PRESS® Post-Pour Range II LWC≤ 35 PCF (lbs/ ft³) Pre-Pour Structural Concrete @ 3000 psi Installs into Metal Deck, Purlin, or Tubular Steel • The Sammy X-Press expands to provide direct vertical attachment in: - light gauge steel deck or purlin (22 ga. - 1/8”). • Installs in seconds with Sammy X-Press It® Tool, saving time & installation costs. • Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A. Watch a video demonstration atwww.itwbuildex.com Application Product Features • The Sammy X-Press Sidewinder expands to provide horizontal attachment in: - 16 ga - 3/16” steel - purlin, tubular steel. • Installs in seconds with Sammy X-Press It® Tool, saving time & installation costs. • Use in applications where access to the back of the installed fastener is prohibited; ie. metal roof deck, tubular steel, or vapor barrier fabric. • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A. (SWXP) Approvals Rod Size Part Number Model Description Ultimate Pullout (lbs) UL Test Load (lbs) UL Min Thick FM Test Load (lbs) Max Thick Box Qty Case Qty Application HORIZONTAL MOUNT 3/8"8293957 SWXP 35 Sidewinder X-Press 35 1798 (16 ga) 1250 (3½" Pipe) 80 (Luminaire) 416 (Conduit & Cable) .059”.125”25 125 Purlin Watch a video demonstration atwww.itwbuildex.com Application Product Features SAMMY X-PRESS SIDEWINDER™ - Horizontal Application (XP) MANUFACTURED U.S.A. 9 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETE• The Sammy X-Press Swivel allows you to hang plumb in extreme roof pitches: - 89° in z-purlin - 45° in metal deck for 12/12 pitch • Installs in seconds with Sammy X-Press It® Tool, saving time & installation costs. • Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A.(SXP) Installs into Metal Deck, Purlin, or Tubular Steel Approvals Rod Size Part Number Model Description Ultimate Pullout (lbs) UL Test Load (lbs) UL Min Thick FM Test Load (lbs) FM Min Thick Max Thick Box Qty Case Qty Application SWIVEL MOUNT 3/8”8294922 SXP 20 Swivel X-Press 20 1061 (22 ga Vert) 829 (45° Off Vert) 750 (2” Pipe) 170 Vertical (Luminaire) 80 @ 45° (Luminaire) 283 Vertical (Conduit & Cable) 233 @ 45° (Conduit & Cable) .029” 635 (2” Pipe).029”.125”25 125 Metal Deck 3/8"8295922 SXP 35 Swivel X-Press 35 1675 (16 ga Vert) 1558 (89° Off Vert) 1250 (3-1/2" Pipe) 250 Vertical (Luminaire) 80 @ 90° (Luminaire) 500 Vertical (Conduit & Cable) 333 @ 89° (Conduit & Cable) .059” 635 (2" Pipe).029”.125”25 125 Purlin 1/2”8272957 SXP 2.0 Swivel X-Press 2.0 1061 (22 ga Vert) 829 (45° Off Vert).027” .125”25 125 Metal Deck 1/2"8271957 SXP 3.5 Swivel X-Press 3.5 1675 (16 ga Vert) 1558 (89° Off Vert).060".125”25 125 Purlin • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A. Watch a video demonstration atwww.itwbuildex.com Application Product Features *Tool Includes: Sleeve, Bit Receiver, Hex Wrench, and 25/64” Drill Bit. Part Number Model Description Qty 8194910 UXPIT*Universal X-Press It Tool 1 8152910 XPDB 25/64" Drill Bit 1 SAMMY X-PRESS IT® Installation Tool • The Sammy X-Press expands to provide direct vertical attachment in: - metal deck (22-16 gauge) - z-purlin (18-16 gauge) • Manufactured in the U.S.A. Watch a video demonstration atwww.itwbuildex.com Application Product Features • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A. SAMMY X-PRESS SWIVEL™ - Swivel Application 10 For the most up to date information, visit www.itwbuildex.com SAMMYS® FOR CONCRETE - Vertical Application Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs)* FM Test Load (lbs) Box Qty Case Qty VERTICAL MOUNT 1/4"8058957 CST 200 5/16 x 1-3/4"2400 25 125 3/8"8059957 CST 20 5/16 x 1-3/4"2400 1475 25 125 3/8"8145925 CST 20-SS 5/16 x 1-3/4"2400 25 125 1/2"8060925 CST 2 5/16 x 1-3/4"2400 25 125 #14 BlackNut DriverPart # 8113910 #14SW Red Nut DriverPart # 8114910 • Easy two step process (Drill hole & drive Sammys concrete anchor). • ¼” pre-drilled pilot hole required. • Concrete Installation Tool available for a one tool installation process. • Manufactured in the U.S.A. * Tested in 3000 PSI concrete Application Product Features SAMMYS® FOR CONCRETE Watch a video demonstration atwww.itwbuildex.com SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs)* FM Test Load (lbs) Box Qty Case Qty HORIZONTAL MOUNT 1/4"8062957 SWC 200 5/16 x 1-3/4"2450 25 125 3/8"8061957 SWC 20 5/16 x 1-3/4"2450 1475 25 125 #14SW Red Nut DriverPart # 8114910 • Easy two step process (Drill hole & drive Sammys concrete anchor). • ¼” pre-drilled pilot hole required. • Concrete Installation Tool available for a one tool installation process. • Manufactured in the U.S.A. * Tested in 3000 PSI concrete Application Product Features Watch a video demonstration atwww.itwbuildex.com SIDEWINDER® FOR CONCRETE - Horizontal Application MANUFACTURED U.S.A. 11 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETE(a) or (g)(d)(h) (b) (c) Rotary Hammer Drill into concrete Part Number Description Each Qty 8122910 Concrete Installation Kit (a) Kit includes the following items: 8113910 #14 Black Nut Driver (b)1 8114910 #14 SW Red Nut Driver (c)1 8116910 #250 Bit (1/4") (d)1 8117910 SDS Bit (1/4") (e)1 8118910 7/32 Wood Bit (f)1 8120910 HEX 250 Bit Receiver (1/4") (g)1 8098910 SL 250 Sleeve (h)1 8121910 SDS B250 Bit Receiver (1/4”)*1 *Only sold separately - not included in kit. or (e)(h) (b) (c) Hammer Drill into concrete Application CONCRETE / WOOD INSTALLATION KIT Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs)* Box Qty Case Qty SWIVEL MOUNT 3/8"8269957 SH-GST/CST 20 5/16 x 1-3/4" 2537 in 3000 psi concrete 1459 @ 45°off vertical in 3000 psi concrete 2852 in 6000 psi concrete 1636 @ 45°off vertical in 6000 psi concrete 25 125 1/2”8303957 SH-GST/CST 2.0 5/16 x 1-3/4" 2537 in 3000 psi concrete 1459 @ 45°off vertical in 3000 psi concrete 2852 in 6000 psi concrete 1636 @ 45°off vertical in 6000 psi concrete 25 125 * Tested in 3000 PSI concrete Application Product Features #14 SH Orange Nut DriverPart # 8273910 SAMMYS SWIVEL HEAD™ FOR CONCRETE - Swivel Application • Installs vertically and swivels up to 89° in wood & concrete structures. • Eliminates distortion of threaded rod. • 1/4” pre-drilled pilot hole required. • Concrete installation tool available for a one piece installation process. • Manufactured in the U.S.A. Note: UL Listed for wood - see page 5 12 For the most up to date information, visit www.itwbuildex.com SAMMY TOGGLE for Drywall/Concrete Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs)Box Qty Case Qty 1/4"8063925 SST 300 1/4 x 3"450 (Lath & Plaster) 404 (2 Layers 5/8 Rock)25 125 3/8"8064925 SST 30 1/4 x 3"450 (Lath & Plaster) 404 (2 Layers 5/8 Rock)25 125#14 Black Nut DriverPart # 8113910 Pre-Cast Hollow Core Concrete 1. Pre-drill a 5/8” hole with a regular drill or hole saw. 2. Insert SST screw into #14 black nut driver. With wing nut and washer on bolt, insert wing nut through surface, and begin installation. 3. When bolt is secure and nut driver spins free, stop drill motor and remove. 4. SST screw is now ready to receive 1/4”, 3/8”, or Metric all thread rod or bolt stock. Approvals Substrate Part Number Model Point Description Overal Total Length Ultimate Pullout (lbs) Max Gauge ICC Test Load (lbs) Box Qty Case Qty ICC STEEL 8107957 CWSD 1*Teks 1/4 x 1"2”472 (20 ga)16 ga.170 (20 ga.)25 125 ICC STEEL WOOD 8190957 CWSD 15*Gimlet Teks 1/4 x 1-1/2"2-3/4”472 (20 ga) 1393 (Fir)20 ga.170 (20 ga.)25 125 ICC STEEL 8108957 CWSD 2*Teks 1/4 x 2"3-1/4”472 (20 ga)16 ga.170 (20 ga.)25 125 ICC 8110910 CWIT Installation Tool 1CWIT Installation ToolPart # 8110910 Use the Speedy Pole Tool™ for easy installation of ceiling screws without ladders or scaffolding! (see pg 13 for details) • 3/16” eyelet to accommodate common wire size. • ICC approvals can be found at www.itwbuildex.com under Evaluation Report # ER-5367. * Does not comply with ROHS requirements Application Installation Steps Application Product Features CEILING SCREWS SAMMYS TOGGLE™ ACCESSORIES To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETE13 Part Number Model Ea. Qty 8130910 Spot Rite Level 1 • 1/2”, 3/4”, and 1” threading • Magnetic strip for ease of use • Pocket Sized • Lightweight • 3-vial design for measurement of 0º, 45º, and 90º angles • Complies with NFPA 13 Code Changes. • Flashing for dry pendant sprinklers subject to extreme temperature changes. • One piece construction is easy to install. • Pipe diameter markings ensure accurate fit. • EPDM temperature range of -65°F to +250°F. Part Number Description Pipe Outside Diameter Dektite Base Diameter Dektite Height Box Qty 4001910 Mini 1/4” - 1-1/8”3-1/2”1-3/4”20 4003910 1 1/4” - 2”4-3/4”3”10 4004910 2 1-3/4” - 3-1/4”6-1/4”4”10 DEKTITE® PIPE FLASHING Application Product Features SPOT-RITE LEVEL™ (Items not sold seperately) Product Features • The Pole Tool and Universal Socket Kit provide easy and safe installation for: - Sammys - Jack Chain - Threaded Rod - Wire - Pencil Rod - Screws - Ceiling Screws • Ideal for retrofit and hard-to-reach projects in wood and steel. Part Number Description Box Qty 8123910 Pole Tool 6' (3' - 6')1 8124910 Pole Tool 12' (4' - 12')1 8125910 Pole Tool 18' (6' - 18')1 8126910 Pole Tool 24' (8' - 24')1 Speedy Pole Tool Installation (specify choice when ordering pole tool) 8127910 Sammys Socket Driver 1 8128910 Ceiling Wire Socket Driver for wire and chain 1 8129910 Universal Pole Tool Socket Kit 1 • Adaptor Plug (a) • Socket Driver for SAMMYS (b) • Socket Driver for Ceiling Wire Screws (c) • Socket Driver for 1/4” Standard Nut Drivers (d) • Stud Plug for Viper or Ladd Powder Actuated Attachment (e)(c) (b) (d) (e)(a) SPEEDY POLE TOOL™ & UNIVERSAL SOCKET KIT Universal Pole Tool Socket Kit (8129910) Includes:Product Features Watch a video demonstration atwww.itwbuildex.com Part Number Model Rod Size Mount Direction UL Max Pipe Size UL Test Load (lbs)UL Min Wood Thickness FM Max Pipe Size FM Test Load (lbs)FM Min Wood Thickness SAMMYS FOR WOOD - PIPE HANGER 8007957 GST 10 3/8”Vertical CPVC 1-1/2”300 1-1/2” 8020957 SWG 10 3/8”Horizontal CPVC 1-1/2”300 1-1/2” 8008957 GST 20 3/8”Vertical 2-1/2”850 1-1/2”4”1475 1-1/2” 8068925 GST 20-SS 3/8”Vertical 2-1/2”850 1-1/2” 8010957 GST 30 3/8”Vertical 4”1500 1-1/2”4”1475 1-1/2” 8009925 GST 25-380 3/8”Vertical 4”1500 1-1/2” 8022925 SWG 25-380 3/8”Horizontal 3-1/2” - 4”*1500 1-1/2” 8021957 SWG 20 3/8”Horizontal 2-1/2” - 3”**1050 1-1/2” 8073925 SWG 20-SS 3/8”Horizontal 2-1/2”850 1-1/2” 8269957 SH-GST/CST 20 3/8”45° Angle off Vertical 2-1/2”850 1-1/2” 8269957 SH-GST/CST 20 3/8”45° Angle off Vertical 4”1500 1-1/2” 8139957 SH-GST 20 3/8”17° Angle off Vertical 3”1050 1-1/2”4”1475 1-1/2” SAMMYS FOR STEEL - PIPE HANGER Min Steel Thick Max Steel Thick 8038957 DSTR 1 3/8”Vertical 4”1500 .035”4”1475 .105” 8037957 DSTR 1-1/2 3/8” Vertical 4”1500 .035”4”1475 .105” 8039957 DSTR 516 3/8”Vertical 4”1500 .037”4”1475 .105” 8045957 DST 516 3/8”Vertical 4”1500 .188”4”1475 .188” 8046957 TEK 50 3/8”Vertical 4”1500 .250”4”1475 .188” 8055957 SWDR 1 3/8”Horizontal 4”1500 .037”4”1475 .060” 8056957 SWDR 516 3/8”Horizontal 4”1500 .037”4”1475 .060” 8054957 SWDR 1-1/2 3/8”Horizontal 4”1500 .037”4”1475 .060” 8137957 SH-DSTR 1 3/8”17° Angle off Vertical 4”1500 .035”4”1475 .105” 8268957 SH-TEK 50 3/8”Vertical 2-1/2”850 70° Angle off Vertical 4”1500 8150922 XP 20 3/8”Vertical 2-1/2”850 .027”2”940 .029” 4”1475 .105” 8153922 XP 35 3/8”Vertical 4”1500 .060”2”940 .029” 4”1475 .125” 8294922 SXP 20 3/8”Vertical or up to 45°2”750 .027”2”635 .029” 8295922 SXP 35 3/8”Vertical or up to 89°3-1/2”1250 .060”2”635 .029” 8293957 SWXP 35 3/8”Horizontal 3-1/2”1250 .060” SAMMYS FOR CONCRETE - PIPE HANGER 8059957 CST 20 3/8”Vertical 4”1475 3000 8061957 SWC 20 3/8”Horizontal 4”1475 3000 8150922 XP 20 3/8”Vertical 2-1/2”850 Pre-Pour Structural @ 3000psi 8150922 XP 20 3/8”Vertical 2-1/2”850 Post-Pour Range II LWC ≤ 35 PCF (lbs/ft3) 14 Part Number Model Rod Size Mount Direction UL Load Rating (lbs)UL Min Steel Thickness SAMMYS FOR STEEL - LUMINAIRE FITTING 8150922 XP 20 3/8”Vertical 185 .027” 250 .035” 8153922 XP 35 3/8”Vertical 185 .027” 250 .035” 8181922 XP 200 1/4”Vertical 185 .027” 250 .035” 8294922 SXP 20 3/8”Vertical 170 .027” 45°80 .027” 8295922 SXP 35 3/8”Vertical 250 .060” 90°80 .060” 8293957 SWXP 35 3/8”Horizontal 80 .060” Sheet Steel Gauges Gauge No.22 ga.20 ga.18 ga.16 ga.14 ga.12 ga.1/8”3/16”1/4” Nominal Decimal Equivalent .030”.036”.048”.060”.075”.105”.125”.188”.250” Part Number Model Rod Size Mount Direction UL Load Rating (lbs)UL Min. SteelThickness Listed Application SAMMYS FOR STEEL - CONDUIT, TUBING, AND CABLE 8150922 XP 20 3/8”Vertical 283 .027”Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8”Vertical 500 .060”Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3/8”Vertical 283 .027”Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8”Vertical 500 .060”Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8293957 SWXP 35 3/8”Horizontal 500 .060”Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8149957 CZ2000 1/4” or 3/8”Onto Vertical Rod UL Listed 4S16 - Cable Hanger, Cat. No. C-Z2000 Plenum Rated, Complies w/ NEC Standards *SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2” *SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4” **SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2” **SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3” UL compliance with NEC Standards. UL and FM tests were performed in compliance with NFPA 13 Standards. Fastening requirement: 5 times weight of water-filled schedule 40 pipe plus 250 pounds. APPROVALS For the most up to date information, visit www.itwbuildex.com 15 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETEPart NumberModelRod SizeMount DirectionUL Max Pipe SizeUL Test Load (lbs)UL Min Wood ThicknessFM Max Pipe SizeFM Test Load (lbs)FM Min Wood Thickness SAMMYS FOR WOOD - PIPE HANGER 8007957GST 103/8”VerticalCPVC 1-1/2”3001-1/2” 8020957SWG 103/8”HorizontalCPVC 1-1/2”3001-1/2” 8008957GST 203/8”Vertical2-1/2”8501-1/2”4”14751-1/2” 8068925GST 20-SS3/8”Vertical2-1/2”8501-1/2” 8010957GST 303/8”Vertical4”15001-1/2”4”14751-1/2” 8009925GST 25-3803/8”Vertical4”15001-1/2” 8022925SWG 25-3803/8”Horizontal3-1/2” - 4”*15001-1/2” 8021957SWG 203/8”Horizontal2-1/2” - 3”**10501-1/2” 8073925SWG 20-SS3/8”Horizontal2-1/2”8501-1/2” 8269957SH-GST/CST 203/8”45° Angle off Vertical2-1/2”8501-1/2” 8269957SH-GST/CST 203/8”45° Angle off Vertical4”15001-1/2” 8139957SH-GST 203/8”17° Angle off Vertical3”10501-1/2”4”14751-1/2” SAMMYS FOR STEEL - PIPE HANGERMin Steel ThickMax Steel Thick 8038957DSTR 13/8”Vertical4”1500.035”4”1475.105” 8037957DSTR 1-1/23/8” Vertical4”1500.035”4”1475.105” 8039957DSTR 5163/8”Vertical4”1500.037”4”1475.105” 8045957DST 5163/8”Vertical4”1500.188”4”1475.188” 8046957TEK 503/8”Vertical4”1500.250”4”1475.188” 8055957SWDR 1 3/8”Horizontal4”1500.037”4”1475.060” 8056957SWDR 5163/8”Horizontal4”1500.037”4”1475.060” 8054957SWDR 1-1/23/8”Horizontal4”1500.037”4”1475.060” 8137957SH-DSTR 13/8”17° Angle off Vertical4”1500.035”4”1475.105” 8268957SH-TEK 503/8”Vertical2-1/2”850 70° Angle off Vertical4”1500 8150922XP 203/8”Vertical2-1/2”850.027”2”940.029” 4”1475.105” 8153922XP 353/8”Vertical4”1500.060”2”940.029” 4”1475.125” 8294922SXP 203/8”Vertical or up to 45°2”750.027”2”635.029” 8295922SXP 353/8”Vertical or up to 89°3-1/2”1250.060”2”635.029” 8293957SWXP 353/8”Horizontal3-1/2”1250.060” SAMMYS FOR CONCRETE - PIPE HANGER 8059957CST 203/8”Vertical4”14753000 8061957SWC 203/8”Horizontal4”14753000 8150922XP 203/8”Vertical2-1/2”850Pre-Pour Structural @ 3000psi 8150922XP 203/8”Vertical2-1/2”850Post-Pour Range II LWC ≤ 35 PCF (lbs/ft3) SPECIAL NOTES Engineering Note In 1996, the anchors listed by UL were tested in plate steel that measured .188” and .118”. Subsequent testing was done for z-purlin applications in May 1997 using (.037”) or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Press® was completed using (.030”) or 22 gauge steel metal deck. Sammys® Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric ProductsMetric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for SeismicPlease visit www.itwbuildex.com for our current Seismic product offerring. Vibratory Environments For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8” smaller than root diameter of fastener. Consult the table below: To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPA/NEC StandardsAll UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings / FM ApprovalsUL and FM reports are available at www.itwbuildex.com Technical DrawingsTechnical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Manufactured in the U.S.A. Products Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 Model Root Diameter Hole Size GST 20 .182”1/8” GST 25-380 .280”7/32” SWG 20 .182”1/8” SWG 25-380 .280”7/32” MANUFACTURED U.S.A. OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org August 30, 2021 J C Fire Protection 81705 De Oro Ave Indio, CA 92201 Re: TI Fire Sprinkler Plan Review – La Quinta Country Club - CLUBHOUSE 77750 AVENUE 50, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. The following inspections/tests are required to be witnessed by the Office of the Fire Marshal staff: 1) Overhead Rough: All installed/relocated piping must be visible. 2) Final inspection: All trim is in place, 5-Year certification is current. New/added heads shall be included in the spare head box compliment. *Water-flow signal test may be performed during the Final Inspection. All persons performing work on the automatic fire sprinkler system shall be Certified Sprinkler Fitters or Registered with the State Fire Marshal for Apprentice or Trainee classification. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 77750 AVENUE 50 PERMIT#: FSS2021-0184 DATE ISSUED: 8/30/2021 DESCRIPTION: LQ COUNTRY CLUB – CLUBHOUSE TI CONTRACTOR: JC FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. DESIGN & DEVELOPMENT DEPARTMENT 78-495 Calle Tampico La Quinta, California 92253 (760) 777-7125 / FAX (760) 777-7011 OFFICE USE ONLY: REVIEW DATE: ______________  APPROVED  CORRECTIONS CALLED FOR PICKUP:_________ PICKED UP:_________________  SUBMITTAL #_________  REVISION #________ PERMIT NO. APPLICANT/OWNER INFORMATION Applicant Name: Owner Name: Mailing Address: Site Address: Phone Number: Project Email: Description: (Include # of sprinkler heads) Pursuant to a Cooperative Agreement to Provide Fire Services, the Riverside County Fire Department serves as the City’s fire department, and the County designee serves as the City’s fire chief. Applicant recognizes this contracted arrangement and shall comply with County Fire Department directions. CONTRACTOR INFORMATION Contractor Name: Contractor #: Signature: Contact Person: Mailing Address: Print Name: City, State, Zip: Phone Number: Business License #: Email Address: ------------ HOURLY@161/HR $670 HOURLY@161/HR $791 $992 $418 $1234 HOURLY@161/HR $418 ------------ HOURLY@161/HR $418 $499 $740 $579 HOURLY@161/HR ------------ HOURLY@161/HR $176 $901 $257 HOURLY@161/HR $337 $659 $590 $579 $418 $418 $161 $1062 HOURLY@161/HR 1/29/2020 ■ Javier Cordova 81705 de oro ave. Indio,ca 92201 (760)625-5908 77-750 avenue 50 Commercial t.i adding 3 heads jcfireprotection@verizon.net JC FIRE PROTECTION 996335 Javier Cordova 81705 DE ORO AVE Javier Cordova INDIO, CA 92201 760-625-5908 jcfireprotection@verizon.net ✔ Javier Cordova