FSS2021-0226ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT RESIDENTIAL FIRE PROTECTION DBA ON GUARD 6438 ARVILLE ST LAS VEGAS NV 89118 (702)966-8021 VanesaH@ONGUARDF P.COM CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE JOSE DELGADO 5/5/2022 5/5/2022 CONTRACTOR REQUESTED FINAL INSPECTION. PERMIT EXPIRED AS OF 4/23/22. ADDED EXTENSION FEE OF $83 AND EXTENDED PERMIT TO 5/6/22 SO CONTRACTOR CAN PAY FEE VIA ETRAKIT. CONTRACTOR UPLOADED EXTENSION LETTER. OK TO EXTEND PER KOHL. PAYMENT FOR EXTENSION FEE WAS MADE ON 5/5/22, EXTENDED PERMIT ANOTHER 6 MONTHS FROM 5/5/22 TO 11/5/22 CONDITIONS Description: FOR THE USE IN DESIGN & INSTALL OF A NEW FIRE SPRINKLER SYS. Type: FIRE SPRINKLER (WEB)Subtype: Status: FINALED Applied: 9/13/2021 ECON Parcel No: 774113029 Site Address: 53705 AVENIDA ALVARADO LA QUINTA,CA 92253 Approved: 9/28/2021 KHET Subdivision: SANTA CARMELITA AT VALE LA QUINTA UNIT 19 Block: Lot: 11 Issued: 9/28/2021 AHI Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 7/6/2022 LIN Valuation: $5,560.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: PER NFPA 13D 2016 EDITION Printed: Thursday, March 02, 2023 4:09:59 PM 1 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0226 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL CONTRACTOR ON GUARD FIRE PROTECTION 11800 STERLING AVE, SUITE K RIVERSIDE CA 92503 (702)966-8021 OSCARG@ONGUARDFP .COM OWNER FINLEY JAMES LLC 3419 VIA LIDO NEWPORT BEACH CA 92663 (702)966-8021 FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $167.00 $167.00 6/13/22 WEB12151 637655077 38 CREDIT 950378 ECON FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $167.00 $167.00 6/29/22 WEB12375 637903704 58 CREDIT 950378 ECON FIRE PLAN REVISION SUBMITTALS 101-0000-42420 0 $167.00 $167.00 5/5/22 WEB11653 636964796 22 CREDIT 950378 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $161.00 $161.00 9/28/21 WEB9424 632685992 81 CREDIT 950378 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $242.00 $242.00 9/28/21 WEB9424 632685992 81 CREDIT 950378 ECON FIRE STAFF - PER HOUR 101-0000-42420 1 $83.00 $83.00 5/5/22 WEB11653 636964796 22 CREDIT 950378 ECON Total Paid for FIRE FEES: $987.00 $987.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 9/28/21 WEB9424 632685992 81 CREDIT 950378 ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 Printed: Thursday, March 02, 2023 4:09:59 PM 2 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0226 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 10/25/2021 10/25/2021 APPROVED REVISED PLANS/CALCS REQD Revised plans and calcs required prior to final. OVERHEAD HYRO KHET 10/25/2021 10/25/2021 APPROVED FIRE FINAL**KHET 5/16/2022 5/16/2022 DISAPPROVE D SEE NOTES Residual Flow showed ~20 psi at BOR. Suspect Main-to-WM issue. Offered Bucket- Test to confirm minimum compliance - if not capable, CVWD will need to assess supply issue. FIRE FINAL**LIN 6/23/2022 6/23/2022 APPROVED W/EXCEPTIO N Missing complete address FIRE FINAL**LIN 7/6/2022 7/6/2022 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE - ETRAKIT (2 WK) KOHL HETRICK 9/13/2021 9/27/2021 9/28/2021 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH – ETRAKIT (1 DAY) PERMIT TECH BUCKET 9/13/2021 9/14/2021 9/13/2021 COMPLETE PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 9/28/21 WEB9424 632685992 81 CREDIT 950378 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$1,002.00 $1,002.00 Printed: Thursday, March 02, 2023 4:09:59 PM 3 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0226 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 9/13/2021 Etrakit Contractor 1ST SUBMITTAL FIRE SPRINKLER PLANS 00 53-705 ALVARADO RES FS PLAN- D0.pdf 1 DOC 9/13/2021 Etrakit Contractor 1ST SUBMITTAL FIRE SPRINKLER HYDRAULIC CALCS 01 53-705 ALVARADO RES HYD CALC- D0.pdf 1 DOC 9/13/2021 Etrakit Contractor 1ST SUBMITTAL MATERIAL SPEC SHEETS W/ FLOW TEST OGFP MATERIAL SUBMITTAL- AVENIDA ALVARADO.pdf 1 DOC 9/13/2021 Etrakit Contractor APPROVED BUILDING PLANS 53-705 Approved Plans.pdf 1 DOC 11/10/2021 Etrakit Contractor Updated set of Plan due to the water meter size change HYD CALCS 53-705 ALVARADO RES. D1.PDF 1 DOC 11/10/2021 Etrakit Contractor New hydraulic calcs w/the new water meter. 00 53-705 ALVARADO RES. FS PLANS D1.pdf 1 DOC 5/5/2022 Etrakit Contractor OGFP Permit Extension Letter FSS2021- 0226.docx 1 DOC 9/28/2021 KOHL HETRICK FSS2021-0226 - APPROVED PLANS AND CALCS.pdf FSS2021-0226 - APPROVED PLANS AND CALCS.pdf 1 DOC 9/28/2021 KOHL HETRICK FSS2021-0226 - COA AND JOB CARD.pdf FSS2021-0226 - COA AND JOB CARD.pdf 1 DOC 10/25/2021 KOHL HETRICK FSS2021-0226 Insp Notes.pdf FSS2021-0226 Insp Notes.pdf 1 BOND INFORMATION 2ND FIRE (1 WK)KOHL HETRICK 11/10/2021 11/17/2021 11/22/2021 APPROVED SEE ATTACHMENTS Printed: Thursday, March 02, 2023 4:09:59 PM 4 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0226 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/22/2021 KOHL HETRICK FSS2021-0226 - REV 1 - APPROVED PLANS AND CALCS.pdf FSS2021-0226 - REV 1 - APPROVED PLANS AND CALCS.pdf 1 Printed: Thursday, March 02, 2023 4:09:59 PM 5 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0226 ObstructionN.N.GENERAL CONDITIONSTHIS DRAWING AND THE INFORMATION AND DESIGNAPPLICATIONS HEREIN CONTAINED ARE THE PROPERTYOF ON GUARD FIRE PROTECTION AND ARE LOANEDUPON THE EXPRESS CONDITIONS THAT THE SAME BERETURNED TO ON GUARD FIRE PROTECTION UPONREQUEST. ALL INFORMATION HEREIN CONTAINED SHALLBE TREATED AS SECRET AND CONFIDENTIAL. NOREPRODUCTION OF THESE DRAWINGS OR ANY PART OFTHE THEREOF SHALL BE MADE WITHOUT WRITTENCONSENT OF ON GUARD FIRE PROTECTION. BY WAY OFTHESE GENERAL CONDITIONS, ON GUARD FIREPROTECTION DOES GIVE WRITTEN CONSENT TO THEGENERAL CONTRACTOR AND/OR HOME BUILDER LISTEDON THESE DRAWINGS TO USE THESE DRAWINGS AS PARTOF THEIR PLANNING AND PERMITTING PROCESS. INADDITION, ON GUARD FIRE PROTECTION GIVESCONSENT TO THE PROPERTY OWNER TO REQUEST ACOPY OF THESE DRAWINGS FOR THEIR PRIVATE USEONLY SO LONG AS ALL PAYMENTS FOR SERVICESRENDERED ARE PAID IN FULL. NV Fire Marshal LIC: G-537 & JG-8512http://www.onguardfp.com46438 ARVILLE STREET LAS VEGAS, NEVADA 89118NV LIC: 61307 - CA LIC: 9503783PHONE (702) 966-8021 - FAX (702) 987-1174REVISIONSREV. BYDATEPROJECT ADDRESS:PROJECT NAME:PROJECT CONRTACTOR:O.G.11/10/2021CHANGES TO SPRINKLER HEADS FROM 4.9K TO 3.7K DUE TO WATER METER CHANGE FROM 1" TO ¾"LA QUINTA, CA 92253APN: 774-113-02953-705 AVENIDA ALVARADO FINLEY JAMES LLCLOT 11 CUSTOM SPEC. RESIDENCE 53-705 AVENIDA ALVARADOFSS2021-0226 - REV 1 7'-1"(TRUSS HT)17'-4"10'-0"5'-10"(TRUSS HT)8'-9"39'-0"16'-10" (MAX. BUILDING HT. ABOVE GRADE)2'-0" 12'-5"9'-0"21'-8" R-21 INSUL. R-19 INSUL.R-38 INSUL. TYP EXTERIOR WALL REFER TO 1/A-7 TILE ROOFING ON SHEATING W/ RADIANT BARRIER LOCATION OF HVAC DUCTSW/ R-6 INSUL. CONC. SLAB DINING HALL BEDROOMKITCHEN 3.5:123.5:12 TRUSS 12'-1" (MAX. BUILDING HT. ABOVE GRADE)10'-0"(MAX CLG HT)8'-9"(PLATE HT)11'-3" (TOP OF TRUSS FRAMING)SCISSOR TRUSS R-38 INSUL. CONC. SLAB R-21 INSUL. TILE ROOFING ON SHEATING W/ RADIANT BARRIER TYP EXTERIOR WALL REFER TO 1/A-7 MASTER / CASITAS 3.5:123.5:122'-24'-74'-72'-2ENTRY 13'-4 CLG. TL. 15.00ft² 3'-7 2'-10 9'9'4'-99'5'9'4'-91'-107'10'-115'5'9'-105'4'-72'-25'-114'-93'-1010'-82'-7 7'-6 4'-45'-14'-1014'13'-105'-102'-11 6'-11 3'-7 #2SEC#2SECGARAGE 8'-9 CLG. REMOTE AREA 3 16'X16' SPACING DINING 10'-0 CLG. LAUN. 8'-9 CLG. LIVING 10'-0 CLG. PWDR. 24.71ft² KITCHEN 10'-0 CLG. HALL 8'-9 CLG. BEDRM. 3 8'-9 CLG. HEAT ZONE 8'-9 CLG. 8'-9 CLG. HALL 8'-9 CLG. PANTRY 8'-9 CLG. BATH 4 8'-9 CLG. FAU FAUAA 2'-7 10'-8 3'-6 2'-24'-7MA. W.I.C. 8'-9 CLG. BATH 2 40.96ft² CASITA VAULTED CLG. MA. BATH 8'-9 CLG. REMOTE AREA 2 20'X20' SPACING BEDRM. 2 8'-9 CLG. MA. BEDRM. VAULTED CLG. BATH 3 48.03ft²CLST. 16.64ft² TL. 12.67ft² CLST. 20.00ft² CLST. 15.67ft² REMOTE AREA 1 16'X16' SPACING HEAT ZONE1" RISER LOCATION 101 102 201 ¾ 9'-10 ¾ 7' 1 5'-42'2'¾¾¾10'-11¾3'-9¾ 1' ¾ 10'-3 ¾1'-1 ¾ 4' ¾ 5'-3 ¾ 7'-8 6"¾10'-8 ¾¾8'-3¾6"¾6'-1¾1'-68'-7 ¾¾¾7"¾ 4'-10 ¾1'-1 ¾ 10'-8¾5"¾8'-4¾6"6"¾¾ 5'-11 ¾ 10'-8 ¾ 4'-3 ¾ 2'-7¾2'¾8" ¾ 4'-10¾1'-11¾9"¾6"¾12'-7¾2'-8¾7'-2¾ 8'-7 ¾ 2'-6¾4'-5¾3'-2¾2'-24'-1¾2' ¾6"¾¾2'-11¾5"10'-8¾5"¾5"¾ 3'-11 ¾5'-111'-4 ¾¾3'-86"¾¾ 2'-8 ¾3'-8¾11"¾ 7'-2 11"¾¾2'-1¾4'-3UP ¾ X 3'-0 10150 152154 156 162 164 166 168 170 UP ¾" X 1'-9" UP ¾" X 1'-9" UP ¾" X 1'-9" UP ¾" X 1'-9" UP ¾" X 1'-9" 301 302 #1 SEC #1 SEC ¾ 3'-11 ¾ 3'-11 ¾6"¾ 1'-10 ¾ 2'-9 ¾9'-2¾4'-10¾4'-2¾5'-1¾5'-7¾9'-9¾ 10'-4 ¾ 4' 6" ¾ 3'-11 ¾¾7'-8¾14'-6¾13'-10¾7'-32'-9 ¾ 172 160 158 UP ¾" X 3'-0" TO FAU Hydraulic Information Remote Area 2- 20'X20' SPACING OCCUPANCY CLASSIFICATION Residential DENSITY (gpm/ft²)0.05 for 400.00ft² (Actual 162.58ft²) TOTAL HOSE STREAMS 5.00 TOTAL HEADS FLOWING 1 K-FACTOR 4.9 TOTAL WATER REQUIRED 26.02 TOTAL PRESSURE REQUIRED 56.502 BASE of RISER (gpm)21.02 BASE of RISER (psi)33.409 SAFETY MARGIN (psi)+5.279 (8.5%) Hydraulic Information Remote Area 1- 16'X16' SPACING OCCUPANCY CLASSIFICATION Residential DENSITY (gpm/ft²)0.05 for 512.00ft² (Actual 113.39ft²) TOTAL HOSE STREAMS 5.00 TOTAL HEADS FLOWING 2 K-FACTOR 3.7 TOTAL WATER REQUIRED 25.09 TOTAL PRESSURE REQUIRED 43.564 BASE of RISER (gpm)20.09 BASE of RISER (psi)22.349 SAFETY MARGIN (psi)+18.219 (29.5%) Hydraulic Information Remote Area 3- 16'X16' SPACING OCCUPANCY CLASSIFICATION Residential DENSITY (gpm/ft²)0.05 for 512.00ft² (Actual 255.18ft²) TOTAL HOSE STREAMS 5.00 TOTAL HEADS FLOWING 2 K-FACTOR 3.7 TOTAL WATER REQUIRED 25.17 TOTAL PRESSURE REQUIRED 42.516 BASE of RISER (gpm)20.17 BASE of RISER (psi)21.149 SAFETY MARGIN (psi)+19.266 (31.2%)GENERAL CONDITIONSTHIS DRAWING AND THE INFORMATION AND DESIGNAPPLICATIONS HEREIN CONTAINED ARE THE PROPERTYOF ON GUARD FIRE PROTECTION AND ARE LOANEDUPON THE EXPRESS CONDITIONS THAT THE SAME BERETURNED TO ON GUARD FIRE PROTECTION UPONREQUEST. ALL INFORMATION HEREIN CONTAINED SHALLBE TREATED AS SECRET AND CONFIDENTIAL. NOREPRODUCTION OF THESE DRAWINGS OR ANY PART OFTHE THEREOF SHALL BE MADE WITHOUT WRITTENCONSENT OF ON GUARD FIRE PROTECTION. BY WAY OFTHESE GENERAL CONDITIONS, ON GUARD FIREPROTECTION DOES GIVE WRITTEN CONSENT TO THEGENERAL CONTRACTOR AND/OR HOME BUILDER LISTEDON THESE DRAWINGS TO USE THESE DRAWINGS AS PARTOF THEIR PLANNING AND PERMITTING PROCESS. INADDITION, ON GUARD FIRE PROTECTION GIVESCONSENT TO THE PROPERTY OWNER TO REQUEST ACOPY OF THESE DRAWINGS FOR THEIR PRIVATE USEONLY SO LONG AS ALL PAYMENTS FOR SERVICESRENDERED ARE PAID IN FULL. Sprinkler LegendSymbolSpacingManufacturerSINModel K TypeSizeFinishTemp.Qty.14'X14'Senju Sprinkler Co., LTDSS8261RC-RES3.7Pendent½White162°F2420'X20'Senju Sprinkler Co., LTDSS8464RC-RES4.9Pendent½White162°F414'X14'Senju Sprinkler Co., LTDSS8261RC-RES3.7Pendent½White205°F5120ft²VikingATTICVK6964.2Upright½Brass200°F2Total = 354132AS NOTED 21-20C-004 10/26/2021 FIRE SPRINKLER LAYOUT JR V. FP2 OF 2http://www.onguardfp.com 6438 ARVILLE STREET LAS VEGAS, NEVADA 89118 NV LIC: 61307 - CA LIC: 950378 PHONE (702) 966-8021 - FAX (702) 987-1174 NV Fire Marshal LIC: G-537 & JG-85 REVISIONSDATEREV. BYPROJECT CONRTACTOR:TITLE: DATE: DRAWN: PROJECT NO:PROJECT NAME:SHEET:PROJECT ADDRESS:SCALE:TO WATER METER CHANGE FROM 1" TO ¾"O.G.CHANGES TO SPRINKLER HEADS FROM 4.9K TO 3.7K DUE11/10/202153-705 AVENIDA ALVARADO LOT 11 CUSTOM SPEC. RESIDENCE LA QUINTA, CA 9225353-705 AVENIDA ALVARADOAPN: 774-113-029FINLEY JAMES LLCON L ICT LICENSE NO. C-16RE A RR ETF NTAOTC T RFORCLASSIFICATION S O F TC OF950378 OA II E C N IPAFIRE SPRINKLER FLOOR PLAN SCALE: 1/4" = 1'-0 SECTION VIEW #1 SCALE: 1/4" = 1'-0 SECTION VIEW #2 SCALE: 1/4" = 1'-0 HYDRAULIC CALC BRES2020-02722,798SF DWELLING -[VB/RES-3/CLASSA-FR/13D] THISPERMIT DOES NOTINCLUDE PV SYSTEM,POOL, SPA, BLOCKWALLS OR DRIVEWAYAPPROACH. 2019CALIFORNIA BUILDINGCODES.02/22/2021 Know what'sR1-26-21 Know what'sR1-26-21 02/22/2021 02/22/2021 02/22/2021 02/22/2021 02/22/2021 02/22/2021 02/22/2021 02/22/2021 02/22/2021 02/22/2021 ϱ%"-&-03&/'03 #&4 $*7*-'*/-&:+".&4--$-53-705 AVENIDA ALAVARADOLA QUINTA, CA.N:\Files\L333\L333sgn.dwg, 12/7/2020 10:58:00 AM, PDF.pc302/22/2021 %"-&-03&/'03 #&4 $*7*-'*/-&:+".&4--$-53-705 AVENIDA ALAVARADOLA QUINTA, CA.N:\Files\L333\L333s-1.dwg, 12/7/2020 10:58:09 AM, PDF.pc302/22/2021 %"-&-03&/'03 #&4 $*7*-'*/-&:+".&4--$-53-705 AVENIDA ALAVARADOLA QUINTA, CA.N:\Files\L333\L333s-2.dwg, 12/7/2020 10:58:17 AM, PDF.pc302/22/2021 <%"-&-03&/'03 #&4 $*7*-'*/-&:+".&4--$-53-705 AVENIDA ALAVARADOLA QUINTA, CA.N:\Files\L333\L333fd1.dwg, 12/7/2020 10:58:23 AM, PDF.pc302/22/202102/22/2021 %"-&-03&/'03 #&4 $*7*-'*/-&:+".&4--$-53-705 AVENIDA ALAVARADOLA QUINTA, CA.N:\Files\L333\L333sd1.dwg, 12/7/2020 10:58:28 AM, PDF.pc302/22/2021 Hydraulic Calculations Location: 53705 AVENIDA ALVARADO, LA QUINTA, CA 92253, Project Name: 53-705 ALVARADO Drawing Name: 53-705 ALVARADO RES- D1 Calculation Date: 10/26/2021 for Design Remote Area Location: Residential Area of Application: 512.00ft² (Actual 113.39ft²) Coverage per Sprinkler: 256.00ft² Type of sprinklers calculated: 2 MASTER BEDROOM 1- 16'X16' SPACINGRemote Area Number: Occupancy Classification: No. of sprinklers calculated: Density 0.050gpm/ft² Pendent No. of nozzles calculated:0 In-rack Demand: Hose Streams:at Node:Type:Allowance at Source N/Aat Node:N/A gpm 10.0 gpm 5.00 HoseType:500at Node: (including Hose Streams where applicable):Total Water Required 43.564@25.09From Water Supply at Node 1:(Safety Margin = 18.219) Type of System: WET, 13D Volume of Dry/PreAction/Antifreeze/OtherAgent System:N/A Source:COACHELLA VALLEY WATER DISTRICT Location:AVENIDA ALVARADO & CALLE ARROBA 08/23/2021Date:for Node:1 Name of Contractor:On Guard Fire Protection LA QUINTAAuthority Having Jurisdiction: Address: Phone Number: Name of designer: 6438 ARVILLE STREET, LAS VEGAS, NV 89118 702-966-8021 OSCAR GARCIA N/A N/A Right:Left:Automatic peaking results Notes: 10/26/2021© M.E.P.CAD, Inc.Page 1AutoSPRINK 2020 v16.3.9.0 9:35:52AM1- 16'X16' SPACING Hydraulic Summary Report Description: Residential (1- 16'X16' SPACING) Job Number: 21-20C-004 Node Flow(gpm) Hose At Node 500 5.00 Total Hose Streams 5.00 Safety MarginRequiredAvailable Node Hose Flow Static Residual Flow Total Demand (gpm) (psi) (psi) (gpm) (psi) (gpm) (psi) (psi) @@Name 1 61.782 43.564 18.219850.0053.91961.794 25.09Water Supply Design EngineerJob Number Total Water Required (Including Hose Allowance) 25.09 Maximum Pressure Unbalance In Loops 0.000 Additional Hose Supplies 0.00 Hose Allowance At Source Supplies 18.82gal Residential 0.050gpm/ft² 256.00ft² 512.00ft² (Actual 113.39ft²) 2 Occupancy Area of Application Coverage Per SprinklerNumber Of Sprinklers Calculated Density Job Suffix Number Of Nozzles Calculated 0 AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area Volume capacity of Dry PipesVolume capacity of Wet Pipes 5.38 between nodes 3 and 4 Maximum Velocity Under Ground 10.74 between nodes 168 and 162 Maximum Velocity Above Ground 3.7 K-Factor 10.00 at 7.305 Most Demanding Sprinkler Data System 53705 AVENIDA ALVARADOLA QUINTA, CA 92253 Job Site/Building LA QUINTA53705 AVENIDA ALVARADO AHJ 95037853-705 ALVARADO Job State Certification/License NumberJob Name: OSCAR GARCIA21-20C-004 Contractor Contractor Number 950378 Name of Contractor: On Guard Fire Protection Address 1 6438 ARVILLE STREET Address 2 LAS VEGAS, NV 89118 Contact Name Contact Title ExtensionPhone 702-966-8021 FAX 702-987-1174 E-mail BOBBY@ONGUARDFP.COM Web-Site BOBBY TAVAKOLI Address 3 Address 1 Address 2 Drawing Name 53-705 ALVARADO RES- D1 System Flow Demand 25.09 Remote Area(s) Address 3 10/26/2021© M.E.P.CAD, Inc.Page 1AutoSPRINK 2020 v16.3.9.0 9:36:13AM Hydraulic Graph Water Supply Node: 1 Job Name: 53-705 ALVARADO Remote Area Number: 1- 16'X16' SPACING Date: 10/26/2021 Summary Sheet N 1.85 © M.E.P.CAD, Inc.10/26/2021 Page 2AutoSPRINK 2020 v16.3.9.0 9:35:54AM Device (gpm) Actual Flow Minimum Flow (gpm)(K) K-Factor (psi) Pressure Summary Of Outflowing Devices Report Description: Residential (1- 16'X16' SPACING) Job Number: 21-20C-004 Sprinkler 101 10.00 10.00 3.7 7.305 Sprinkler 102 10.09 10.00 3.7 7.438 Hose 500 5.00 5.00 0 22.614 Most Demanding Sprinkler Data © M.E.P.CAD, Inc.10/26/2021 Page 3AutoSPRINK 2020 v16.3.9.0 9:35:55AM Job Name: 53-705 ALVARADO Remote Area Number: 1- 16'X16' SPACING Date: 10/26/2021 Node @ @ Supply Analysis Static (psi) Required Pressure (psi)(gpm) Total DemandAvailable (psi) Flow (gpm) Residual (psi)Name 53.9191 43.56425.09850.00 61.78261.794Water Supply Node Analysis NotesDischarge at Node (gpm) Pressure at Node (psi) Node TypeElevation (Foot)Node Number 10'25.0943.564Supply1 8'-9 10.007.305Sprinkler101 8'-9 10.097.438Sprinkler102 1'-1 5.0022.614500 -3'40.8562 -3'27.6293 -3'25.9064 1'-7 22.349Supply5 9'-3 17.26010 9'-3 16.554150 9'-3 13.925152 9'-3 13.124154 9'-3 12.949156 9'-3 9.149162 9'-3 7.515164 9'-3 7.551166 9'-3 9.712168 © M.E.P.CAD, Inc.10/26/2021 Page 4AutoSPRINK 2020 v16.3.9.0 9:35:59AM Date: 10/26/2021 Job Name: 53-705 ALVARADO Remote Area Number: 1- 16'X16' SPACING Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-Factor Elev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 7' 9'-3 8' -0.217 0.463 8'-9 1'101 166 ¾• • • • • Route 1 • • • • •(See Notes) 0.8740 7.30510.00 0.058104 Sprinkler, 10.00 3.7 E(4'), T(3') 150 8' 9'-3 20'-3 1.598 9'-3 12'-3166 162 ¾(See Notes) 0.8740 7.5511.80 0.078934 Flow (q) from Route 2 11.80 E(4'), Tr(1'), T(3') 150 9'-3 2'-8 0.563 9'-3 2'-8162 168 ¾ 0.8740 9.1498.29 0.211236 Flow (q) from Route 6 20.09 150 23' 9'-3 73'-5 3.236 9'-3 50'-5168 156 ¾(See Notes) 0.8740 9.712 0.044067 T(3') 8.61 4Tr(1'), 4E(4') 150 4' 9'-3 6'-2 0.175 9'-3 2'-2156 154 ¾(See Notes) 0.8740 12.949 0.028335 Tr(1') 6.78 T(3') 150 3' 9'-3 18'-2 0.801 9'-3 15'-2154 152 ¾(See Notes) 0.8740 13.1241.83 0.044067 Flow (q) from Route 5 8.61 3Tr(1') 150 9' 9'-3 31'-7 2.630 9'-3 22'-7152 150 ¾(See Notes) 0.8740 13.9253.54 0.083266 Flow (q) from Route 4 12.15 T(3'), 2Tr(1'), E(4') 150 5' 9'-3 10'-4 0.706 9'-3 5'-4150 10 1 (See Notes) 1.1010 16.5547.94 0.068616 Flow (q) from Route 3 20.09 E(5') 150 18' 1'-7 25'-8 3.327 1.762 9'-3 7'-810 5 1 (See Notes) 1.1010 17.260 0.06861620.09 f(-0.000), 2Tr(1'), sCV(5'), 2E(5 '), cplg(1'), BASE OF RISER 150 1'-1 6" 0.217 0.049 1'-7 6"5 500 1 1.0250 22.349 0.09720820.09 150 5'-5 -3'10'-5 1.767 1.525 1'-1 5'500 4 1 (See Notes) 1.0250 22.6145.00 0.14664125.09 2E(2'-8) 150 © M.E.P.CAD, Inc.10/26/2021 Page 5AutoSPRINK 2020 v16.3.9.0 9:36:02AM1- 16'X16' SPACING Date: 10/26/2021 Job Name: 53-705 ALVARADO Remote Area Number: 1- 16'X16' SPACING Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-Factor Elev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit -3'50'1.723 -3'50'4 3 1¼ 1.3800 25.906 0.03445625.09 150 -3'1'13.228 -3'1'3 2 1 (See Notes) 0.9950 27.629 0.16946625.09 WMV(-12.965) 150 7' 10'37' -5.636 8.343 -3'30'2 1 1 (See Notes) 0.9950 40.856 0.16946625.09 AngV(-2.000), T(7'), BalV(-0.05 0), S 150 1 0.00 Hose Allowance At Source 25.09 Route 1Total(Pt) 43.564 4' 9'-3 5' -0.217 0.293 8'-9 1'102 164 ¾• • • • • Route 2 • • • • •(See Notes) 0.8740 7.43810.09 0.059088 Sprinkler, 10.09 3.7 E(4') 150 4' 9'-3 14'-8 0.036 9'-3 10'-8164 166 ¾(See Notes) 0.8740 7.515 0.002437 T(3') 1.80 Tr(1') 150 7.551 Total(Pt)Route 2 19' 11'50'-1 -0.759 3.756 9'-3 31'-1168 172 ¾• • • • • Route 3 • • • • •(See Notes) 0.8740 9.712 0.075002 Tr(1') 11.48 4Tr(1'), 2T(3'), 2E(4') 150 22' 9'-3 81'-3 0.759 3.086 11'59'-3172 150 ¾(See Notes) 0.8740 12.710 0.0379587.94 3E(4'), 7Tr(1'), T(3') 150 16.554 Total(Pt)Route 3 17' 9'-3 53'-8 0.759 0.456 11'36'-8172 152 ¾• • • • • Route 4 • • • • •(See Notes) 0.8740 12.710 0.008488 T(3') 3.54 3Tr(1'), 2E(4'), T(3') 150 13.925 Total(Pt)Route 4 17' 9'-3 69'-9 0.175 9'-3 52'-9156 154 ¾• • • • • Route 5 • • • • •(See Notes) 0.8740 12.949 0.002507 T(3') 1.83 2Tr(1'), 4T(3') 150 © M.E.P.CAD, Inc.10/26/2021 Page 6AutoSPRINK 2020 v16.3.9.0 9:36:02AM1- 16'X16' SPACING Date: 10/26/2021 Job Name: 53-705 ALVARADO Remote Area Number: 1- 16'X16' SPACING Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-Factor Elev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 13.124 Total(Pt)Route 5 13' 9'-3 39'-9 1.634 9'-3 26'-9164 162 ¾• • • • • Route 6 • • • • •(See Notes) 0.8740 7.515 0.041072 Tr(1') 8.29 2T(3'), 2Tr(1'), E(4') 150 9.149 Total(Pt)Route 6 © M.E.P.CAD, Inc.10/26/2021 Page 7AutoSPRINK 2020 v16.3.9.0 9:36:02AM1- 16'X16' SPACING Date: 10/26/2021 Job Name: 53-705 ALVARADO Remote Area Number: 1- 16'X16' SPACING Equivalent Pipe Lengths of Valves and Fittings (C=120 only) 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90°cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90°Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap 4.87 )(150 1.33 140 1.16 130 0.713 100Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc.10/26/2021 Page 8AutoSPRINK 2020 v16.3.9.0 9:36:02AM1- 16'X16' SPACING Hydraulic Calculations Location: 53705 AVENIDA ALVARADO, LA QUINTA, CA 92253, Project Name: 53-705 ALVARADO Drawing Name: 53-705 ALVARADO RES- D1 Calculation Date: 10/26/2021 for Design Remote Area Location: Residential Area of Application: 400.00ft² (Actual 162.58ft²) Coverage per Sprinkler: 256.00ft² Type of sprinklers calculated: 1 BEDROOM 2 2- 20'X20' SPACINGRemote Area Number: Occupancy Classification: No. of sprinklers calculated: Density 0.050gpm/ft² Pendent No. of nozzles calculated:0 In-rack Demand: Hose Streams:at Node:Type:Allowance at Source N/Aat Node:N/A gpm 10.0 gpm 5.00 HoseType:500at Node: (including Hose Streams where applicable):Total Water Required 56.502@26.02From Water Supply at Node 1:(Safety Margin = 5.279) Type of System: WET, 13D Volume of Dry/PreAction/Antifreeze/OtherAgent System:N/A Source:COACHELLA VALLEY WATER DISTRICT Location:AVENIDA ALVARADO & CALLE ARROBA 08/23/2021Date:for Node:1 Name of Contractor:On Guard Fire Protection LA QUINTAAuthority Having Jurisdiction: Address: Phone Number: Name of designer: 6438 ARVILLE STREET, LAS VEGAS, NV 89118 702-966-8021 OSCAR GARCIA N/A N/A Right:Left:Automatic peaking results Notes: 10/26/2021© M.E.P.CAD, Inc.Page 1AutoSPRINK 2020 v16.3.9.0 9:37:00AM2- 20'X20' SPACING Hydraulic Summary Report Description: Residential (2- 20'X20' SPACING) Job Number: 21-20C-004 Node Flow(gpm) Hose At Node 500 5.00 Total Hose Streams 5.00 Safety MarginRequiredAvailable Node Hose Flow Static Residual Flow Total Demand (gpm) (psi) (psi) (gpm) (psi) (gpm) (psi) (psi) @@Name 1 61.782 56.502 5.279850.0053.91961.794 26.02Water Supply Design EngineerJob Number Total Water Required (Including Hose Allowance) 26.02 Maximum Pressure Unbalance In Loops 0.000 Additional Hose Supplies 0.00 Hose Allowance At Source Supplies 18.82gal Residential 0.050gpm/ft² 256.00ft² 400.00ft² (Actual 162.58ft²) 1 Occupancy Area of Application Coverage Per SprinklerNumber Of Sprinklers Calculated Density Job Suffix Number Of Nozzles Calculated 0 AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area Volume capacity of Dry PipesVolume capacity of Wet Pipes 5.58 between nodes 3 and 4 Maximum Velocity Under Ground 11.24 between nodes 170 and 201 Maximum Velocity Above Ground 4.9 K-Factor 21.02 at 18.400 Most Demanding Sprinkler Data System 53705 AVENIDA ALVARADOLA QUINTA, CA 92253 Job Site/Building LA QUINTA53705 AVENIDA ALVARADO AHJ 95037853-705 ALVARADO Job State Certification/License NumberJob Name: OSCAR GARCIA21-20C-004 Contractor Contractor Number 950378 Name of Contractor: On Guard Fire Protection Address 1 6438 ARVILLE STREET Address 2 LAS VEGAS, NV 89118 Contact Name Contact Title ExtensionPhone 702-966-8021 FAX 702-987-1174 E-mail BOBBY@ONGUARDFP.COM Web-Site BOBBY TAVAKOLI Address 3 Address 1 Address 2 Drawing Name 53-705 ALVARADO RES- D1 System Flow Demand 26.02 Remote Area(s) Address 3 10/26/2021© M.E.P.CAD, Inc.Page 1AutoSPRINK 2020 v16.3.9.0 9:37:29AM Hydraulic Graph Water Supply Node: 1 Job Name: 53-705 ALVARADO Remote Area Number: 2- 20'X20' SPACING Date: 10/26/2021 Summary Sheet N 1.85 © M.E.P.CAD, Inc.10/26/2021 Page 2AutoSPRINK 2020 v16.3.9.0 9:37:02AM Device (gpm) Actual Flow Minimum Flow (gpm)(K) K-Factor (psi) Pressure Summary Of Outflowing Devices Report Description: Residential (2- 20'X20' SPACING) Job Number: 21-20C-004 Sprinkler 201 21.02 21.02 4.9 18.400 Hose 500 5.00 5.00 0 33.679 Most Demanding Sprinkler Data © M.E.P.CAD, Inc.10/26/2021 Page 3AutoSPRINK 2020 v16.3.9.0 9:37:04AM Job Name: 53-705 ALVARADO Remote Area Number: 2- 20'X20' SPACING Date: 10/26/2021 Node @ @ Supply Analysis Static (psi) Required Pressure (psi)(gpm) Total DemandAvailable (psi) Flow (gpm) Residual (psi)Name 53.9191 56.50226.02850.00 61.78261.794Water Supply Node Analysis NotesDischarge at Node (gpm) Pressure at Node (psi) Node TypeElevation (Foot)Node Number 10'26.0256.502Supply1 8'-9 21.0218.400Sprinkler201 1'-1 5.0033.679500 -3'53.1272 -3'38.9183 -3'37.0764 1'-7 33.409Supply5 9'-3 28.16710 9'-3 27.399150 9'-3 24.678152 9'-3 24.087154 9'-3 23.958156 9'-3 20.883170 11'23.032172 © M.E.P.CAD, Inc.10/26/2021 Page 4AutoSPRINK 2020 v16.3.9.0 9:37:08AM Date: 10/26/2021 Job Name: 53-705 ALVARADO Remote Area Number: 2- 20'X20' SPACING Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-Factor Elev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 7' 9'-3 11'-9 -0.217 2.700 8'-9 4'-9201 170 ¾• • • • • Route 1 • • • • •(See Notes) 0.8740 18.40021.02 0.229630 Sprinkler, 21.02 4.9 E(4'), T(3') 150 12' 11'27'-11 -0.759 2.908 9'-3 15'-11170 172 ¾(See Notes) 0.8740 20.883 0.10421013.71 2E(4'), Tr(1'), T(3') 150 22' 9'-3 81'-3 0.759 3.608 11'59'-3172 150 ¾(See Notes) 0.8740 23.032 0.0443908.65 3E(4'), 7Tr(1'), T(3') 150 5' 9'-3 10'-4 0.768 9'-3 5'-4150 10 1 (See Notes) 1.1010 27.39912.37 0.074591 Flow (q) from Route 2 21.02 E(5') 150 18' 1'-7 25'-8 3.327 1.915 9'-3 7'-810 5 1 (See Notes) 1.1010 28.167 0.07459121.02 f(-0.000), 2Tr(1'), sCV(5'), 2E(5 '), cplg(1'), BASE OF RISER 150 1'-1 6" 0.217 0.053 1'-7 6"5 500 1 1.0250 33.409 0.10567321.02 150 5'-5 -3'10'-5 1.767 1.630 1'-1 5'500 4 1 (See Notes) 1.0250 33.6795.00 0.15682726.02 2E(2'-8) 150 -3'50'1.842 -3'50'4 3 1¼ 1.3800 37.076 0.03685026.02 150 -3'1'14.209 -3'1'3 2 1 (See Notes) 0.9950 38.918 0.18123826.02 WMV(-12.965) 150 7' 10'37' -5.636 9.011 -3'30'2 1 1 (See Notes) 0.9950 53.127 0.18123826.02 AngV(-2.000), T(7'), BalV(-0.05 0), S 150 1 0.00 Hose Allowance At Source 26.02 Route 1Total(Pt) 56.502 © M.E.P.CAD, Inc.10/26/2021 Page 5AutoSPRINK 2020 v16.3.9.0 9:37:11AM2- 20'X20' SPACING Date: 10/26/2021 Job Name: 53-705 ALVARADO Remote Area Number: 2- 20'X20' SPACING Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-Factor Elev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 9' 9'-3 31'-7 2.721 9'-3 22'-7152 150 ¾• • • • • Route 2 • • • • •(See Notes) 0.8740 24.6787.31 + 5.07 0.086157 Flow (q) from Route 3 and 4 12.37 T(3'), 2Tr(1'), E(4') 150 27.399 Total(Pt)Route 2 4' 9'-3 6'-2 0.129 9'-3 2'-2156 154 ¾• • • • • Route 3 • • • • •(See Notes) 0.8740 23.9587.31 0.020902 Tr(1'), Flow (q) from Route 6 5.75 T(3') 150 3' 9'-3 18'-2 0.591 9'-3 15'-2154 152 ¾(See Notes) 0.8740 24.0871.55 0.032506 Flow (q) from Route 5 7.31 3Tr(1') 150 24.678 Total(Pt)Route 3 17' 9'-3 53'-8 0.759 0.887 11'36'-8172 152 ¾• • • • • Route 4 • • • • •(See Notes) 0.8740 23.032 0.016523 T(3') 5.07 3Tr(1'), 2E(4'), T(3') 150 24.678 Total(Pt)Route 4 17' 9'-3 69'-9 0.129 9'-3 52'-9156 154 ¾• • • • • Route 5 • • • • •(See Notes) 0.8740 23.9587.31 0.001849 T(3'), Flow (q) from Route 6 1.55 2Tr(1'), 4T(3') 150 24.087 Total(Pt)Route 5 29' 9'-3 94'-7 3.076 9'-3 65'-7170 156 ¾• • • • • Route 6 • • • • •(See Notes) 0.8740 20.883 0.032506 T(3') 7.31 7Tr(1'), T(3'), 4E(4') 150 23.958 Total(Pt)Route 6 © M.E.P.CAD, Inc.10/26/2021 Page 6AutoSPRINK 2020 v16.3.9.0 9:37:11AM2- 20'X20' SPACING Date: 10/26/2021 Job Name: 53-705 ALVARADO Remote Area Number: 2- 20'X20' SPACING Equivalent Pipe Lengths of Valves and Fittings (C=120 only) 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90°cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90°Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap 4.87 )(150 1.33 140 1.16 130 0.713 100Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc.10/26/2021 Page 7AutoSPRINK 2020 v16.3.9.0 9:37:11AM2- 20'X20' SPACING Hydraulic Calculations Location: 53705 AVENIDA ALVARADO, LA QUINTA, CA 92253, Project Name: 53-705 ALVARADO Drawing Name: 53-705 ALVARADO RES- D1 Calculation Date: 10/26/2021 for Design Remote Area Location: Residential Area of Application: 512.00ft² (Actual 255.18ft²) Coverage per Sprinkler: 256.00ft² Type of sprinklers calculated: 2 DINING/LIVING/KITCHEN 3- 16'X16' SPACINGRemote Area Number: Occupancy Classification: No. of sprinklers calculated: Density 0.050gpm/ft² Pendent No. of nozzles calculated:0 In-rack Demand: Hose Streams:at Node:Type:Allowance at Source N/Aat Node:N/A gpm 10.0 gpm 5.00 HoseType:500at Node: (including Hose Streams where applicable):Total Water Required 42.516@25.17From Water Supply at Node 1:(Safety Margin = 19.266) Type of System: WET, 13D Volume of Dry/PreAction/Antifreeze/OtherAgent System:N/A Source:COACHELLA VALLEY WATER DISTRICT Location:AVENIDA ALVARADO & CALLE ARROBA 08/23/2021Date:for Node:1 Name of Contractor:On Guard Fire Protection LA QUINTAAuthority Having Jurisdiction: Address: Phone Number: Name of designer: 6438 ARVILLE STREET, LAS VEGAS, NV 89118 702-966-8021 OSCAR GARCIA Right: 41.905 N/ALeft:Automatic peaking results Notes: 10/26/2021© M.E.P.CAD, Inc.Page 1AutoSPRINK 2020 v16.3.9.0 9:38:06AM3- 16'X16' SPACING Hydraulic Summary Report Description: Residential (3- 16'X16' SPACING) Job Number: 21-20C-004 Node Flow(gpm) Hose At Node 500 5.00 Total Hose Streams 5.00 Safety MarginRequiredAvailable Node Hose Flow Static Residual Flow Total Demand (gpm) (psi) (psi) (gpm) (psi) (gpm) (psi) (psi) @@Name 1 61.782 42.516 19.266850.0053.91961.794 25.17Water Supply Design EngineerJob Number Total Water Required (Including Hose Allowance) 25.17 Maximum Pressure Unbalance In Loops 0.000 Additional Hose Supplies 0.00 Hose Allowance At Source Supplies 18.82gal Residential 0.050gpm/ft² 256.00ft² 512.00ft² (Actual 255.18ft²) 2 Occupancy Area of Application Coverage Per SprinklerNumber Of Sprinklers Calculated Density Job Suffix Number Of Nozzles Calculated 0 AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area Right: 41.905 Volume capacity of Dry PipesVolume capacity of Wet Pipes 5.40 between nodes 3 and 4 Maximum Velocity Under Ground 10.38 between nodes 1 and 2 Maximum Velocity Above Ground 3.7 K-Factor 10.00 at 7.305 Most Demanding Sprinkler Data System 53705 AVENIDA ALVARADOLA QUINTA, CA 92253 Job Site/Building LA QUINTA53705 AVENIDA ALVARADO AHJ 95037853-705 ALVARADO Job State Certification/License NumberJob Name: OSCAR GARCIA21-20C-004 Contractor Contractor Number 950378 Name of Contractor: On Guard Fire Protection Address 1 6438 ARVILLE STREET Address 2 LAS VEGAS, NV 89118 Contact Name Contact Title ExtensionPhone 702-966-8021 FAX 702-987-1174 E-mail BOBBY@ONGUARDFP.COM Web-Site BOBBY TAVAKOLI Address 3 Address 1 Address 2 Drawing Name 53-705 ALVARADO RES- D1 System Flow Demand 25.17 Remote Area(s) Address 3 10/26/2021© M.E.P.CAD, Inc.Page 1AutoSPRINK 2020 v16.3.9.0 9:38:26AM Hydraulic Graph Water Supply Node: 1 Job Name: 53-705 ALVARADO Remote Area Number: 3- 16'X16' SPACING Date: 10/26/2021 Summary Sheet N 1.85 © M.E.P.CAD, Inc.10/26/2021 Page 2AutoSPRINK 2020 v16.3.9.0 9:38:08AM Device (gpm) Actual Flow Minimum Flow (gpm)(K) K-Factor (psi) Pressure Summary Of Outflowing Devices Report Description: Residential (3- 16'X16' SPACING) Job Number: 21-20C-004 Sprinkler 301 10.00 10.00 3.7 7.305 Sprinkler 302 10.17 10.00 3.7 7.552 Hose 500 5.00 5.00 0 21.415 Most Demanding Sprinkler Data © M.E.P.CAD, Inc.10/26/2021 Page 3AutoSPRINK 2020 v16.3.9.0 9:38:10AM Job Name: 53-705 ALVARADO Remote Area Number: 3- 16'X16' SPACING Date: 10/26/2021 Node @ @ Supply Analysis Static (psi) Required Pressure (psi)(gpm) Total DemandAvailable (psi) Flow (gpm) Residual (psi)Name 53.9191 42.51625.17850.00 61.78261.794Water Supply Node Analysis NotesDischarge at Node (gpm) Pressure at Node (psi) Node TypeElevation (Foot)Node Number 10'25.1742.516Supply1 10'-6 10.007.305Sprinkler301 10'-6 10.177.552Sprinkler302 1'-1 5.0021.415500 -3'39.7542 -3'26.4473 -3'24.7154 1'-7 21.149Supply5 9'-3 16.04810 9'-3 15.336150 9'-3 12.561152 9'-3 11.331154 9'-3 11.062156 11'8.020158 11'8.013160 © M.E.P.CAD, Inc.10/26/2021 Page 4AutoSPRINK 2020 v16.3.9.0 9:38:13AM Date: 10/26/2021 Job Name: 53-705 ALVARADO Remote Area Number: 3- 16'X16' SPACING Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-Factor Elev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 11' 11'15'-11 -0.217 0.926 10'-6 4'-11301 160 ¾• • • • • Route 1 • • • • •(See Notes) 0.8740 7.30510.00 0.058104 Sprinkler, 10.00 3.7 2E(4'), T(3') 150 1' 11'15'-6 0.006 11'14'-6160 158 ¾(See Notes) 0.8740 8.013 0.0004170.69 Tr(1') 150 9' 9'-3 33'-9 0.759 2.283 11'24'-9158 156 ¾(See Notes) 0.8740 8.02010.17 0.067702 Flow (q) from Route 2 10.86 Tr(1'), 2E(4') 150 4' 9'-3 6'-2 0.269 9'-3 2'-2156 154 ¾(See Notes) 0.8740 11.062 0.043533 Tr(1') 8.55 T(3') 150 3' 9'-3 18'-2 1.231 9'-3 15'-2154 152 ¾(See Notes) 0.8740 11.3312.31 0.067702 Flow (q) from Route 6 10.86 3Tr(1') 150 9' 9'-3 31'-7 2.775 9'-3 22'-7152 150 ¾(See Notes) 0.8740 12.5611.64 0.087874 Flow (q) from Route 4 12.51 T(3'), 2Tr(1'), E(4') 150 5' 9'-3 10'-4 0.711 9'-3 5'-4150 10 1 (See Notes) 1.1010 15.3367.66 0.069101 Flow (q) from Route 3 20.17 E(5') 150 18' 1'-7 25'-8 3.327 1.774 9'-3 7'-810 5 1 (See Notes) 1.1010 16.048 0.06910120.17 f(-0.000), 2Tr(1'), sCV(5'), 2E(5 '), cplg(1'), BASE OF RISER 150 1'-1 6" 0.217 0.049 1'-7 6"5 500 1 1.0250 21.149 0.09789520.17 150 5'-5 -3'10'-5 1.767 1.533 1'-1 5'500 4 1 (See Notes) 1.0250 21.4155.00 0.14747125.17 2E(2'-8) 150 -3'50'1.733 -3'50'4 3 1¼ 1.3800 24.715 0.03465125.17 150 © M.E.P.CAD, Inc.10/26/2021 Page 5AutoSPRINK 2020 v16.3.9.0 9:38:16AM3- 16'X16' SPACING Date: 10/26/2021 Job Name: 53-705 ALVARADO Remote Area Number: 3- 16'X16' SPACING Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-Factor Elev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit -3'1'13.307 -3'1'3 2 1 (See Notes) 0.9950 26.447 0.17042525.17 WMV(-12.965) 150 7' 10'37' -5.636 8.398 -3'30'2 1 1 (See Notes) 0.9950 39.754 0.17042525.17 AngV(-2.000), T(7'), BalV(-0.05 0), S 150 1 0.00 Hose Allowance At Source 25.17 Route 1Total(Pt) 42.516 7' 11'11'-5 -0.217 0.685 10'-6 4'-5302 158 ¾• • • • • Route 2 • • • • •(See Notes) 0.8740 7.55210.17 0.059921 Sprinkler, 10.17 3.7 E(4'), T(3') 150 8.020 Total(Pt)Route 2 22' 9'-3 81'-3 0.759 2.886 11'59'-3172 150 ¾• • • • • Route 3 • • • • •(See Notes) 0.8740 11.6929.31 0.035501 Flow (q) from Route 5 7.66 3E(4'), 7Tr(1'), T(3') 150 15.336 Total(Pt)Route 3 17' 9'-3 53'-8 0.759 0.111 11'36'-8172 152 ¾• • • • • Route 4 • • • • •(See Notes) 0.8740 11.6929.31 0.002060 T(3'), Flow (q) from Route 5 1.64 3Tr(1'), 2E(4'), T(3') 150 12.561 Total(Pt)Route 4 30' 11'72'-4 3.678 11'42'-4160 172 ¾• • • • • Route 5 • • • • •(See Notes) 0.8740 8.0130.69 0.050869 Flow (q) from Route 1 9.31 4E(4'), 5Tr(1'), 3T(3') 150 11.692 Total(Pt)Route 5 17' 9'-3 69'-9 0.269 9'-3 52'-9156 154 ¾• • • • • Route 6 • • • • •(See Notes) 0.8740 11.062 0.003852 T(3') 2.31 2Tr(1'), 4T(3') 150 11.331 Total(Pt)Route 6 © M.E.P.CAD, Inc.10/26/2021 Page 6AutoSPRINK 2020 v16.3.9.0 9:38:16AM3- 16'X16' SPACING Date: 10/26/2021 Job Name: 53-705 ALVARADO Remote Area Number: 3- 16'X16' SPACING Equivalent Pipe Lengths of Valves and Fittings (C=120 only) 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90°cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90°Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap 4.87 )(150 1.33 140 1.16 130 0.713 100Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc.10/26/2021 Page 7AutoSPRINK 2020 v16.3.9.0 9:38:16AM3- 16'X16' SPACING FIRE SPRINKLERS – FIRE ALARMS – FIRE EXTINGUISHERS – EMERGENCY LIGHTING – SAFETY & FIRST AID SUPPLIES 6438 Arville St. Las Vegas, NV 89118 (702) 966-8021 Tel (702) 987-1174 Fax www.onguardfp.com License #: NV-61307 CA-950378 Bid Limit $4.5 M MATERIAL SUBMITTAL FOR: 53705 AVENIDA ALVARADO CUSTOM HOME LOT 11 LA QUINTA, CA 92253 GENERAL CONTRACTOR: FINLEY JAMES LLC 09/13/2021 PREPARED BY: ON GUARD FIRE PROTECTION ENGINEERING DEPT. FIRE SPRINKLERS – FIRE ALARMS – FIRE EXTINGUISHERS – EMERGENCY LIGHTING – SAFETY & FIRST AID SUPPLIES Page 2 of 7 6438 Arville St. Las Vegas, NV 89118 (702) 966-8021 Tel (702) 987-1174 Fax www.onguardfp.com License #: NV-61307 CA-950378 Bid Limit $4.5 M TABLE OF CONTENTS: 1. Water Flow Info 2. Sprinkler Heads 3. Pipe & Fittings 4. Valves 5. Accessories & Fire Caulking FIRE SPRINKLERS – FIRE ALARMS – FIRE EXTINGUISHERS – EMERGENCY LIGHTING – SAFETY & FIRST AID SUPPLIES Page 5 of 7 6438 Arville St. Las Vegas, NV 89118 (702) 966-8021 Tel (702) 987-1174 Fax www.onguardfp.com License #: NV-61307 CA-950378 Bid Limit $4.5 M 1. Water Flow FIRE SPRINKLERS – FIRE ALARMS – FIRE EXTINGUISHERS – EMERGENCY LIGHTING – SAFETY & FIRST AID SUPPLIES Page 3 of 7 6438 Arville St. Las Vegas, NV 89118 (702) 966-8021 Tel (702) 987-1174 Fax www.onguardfp.com License #: NV-61307 CA-950378 Bid Limit $4.5 M 2. Sprinkler Heads Page:1 of 8 Document No.U085167 Date:Nov/20/2019 SENJU SPRINKLER CO., LTD. Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 4.9, SIN: SS8464 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. They are decorative and fast responding. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows for easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for residential occupancies and is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar1/2) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents to escape or evacuate in case of a fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. “Lead Free” is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA’s Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. WARNINGS The Model RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or their representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Page:2 of 8 Document No.U085167 Date:Nov/20/2019 TECHNICAL DATA Approvals: cULus Listed NSF/ANSI/CAN 61, NSF/ANSI 372 Sprinkler Identification Number (SIN): SS8464 Maximum Working Pressure: 175psi (12.1bar) Discharge Coefficient (Nominal K-Factor): K=4.9 GPM/psi1/2 (70.6 LPM/bar1/2) Temperature Rating: 162°F (72°C) Sprinkler with 140°F (60°C) Cover Plate 175°F (79°C) Sprinkler with 140°F (60°C) Cover Plate 175°F (79°C) Sprinkler with 162°F (72°C) Cover Plate 205°F (96°C) Sprinkler with 162°F (72°C) Cover Plate Color Code (Sprinkler) 162°F (72°C): Uncolored 175°F (79°C): White 205°F (96°C): White Color Code (Cover Plate) 140°F (60°C): No Mark 162°F (72°C): White-Colored Mark Vertical Adjustment: 1/2 inch (12.8 mm) Cover Plate Finishes: Standard Finishes- White, Ivory, Beige, Brown, Black, Nickel, Wood Grain Custom Finishes- Custom color and custom pattern cover plates are available on special order. Contact a Senju Sprinkler representative with any custom orders. Please see chart on Page 8 for more detail. Physical Characteristics: Ref. Figures 1 and 1-1 FIGURE 1. Model RC-RES K=4.9 FIGURE 1-1. Marking (Color Code) OPERATION In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is reached, internal components of the sprinkler fall apart. This leads to the water flow to be distributed on the affected fire area. (Ref. Figure 2) FIGURE 2. OPERATION PROCESS (The figure is for illustrative purposes only) Page:3 of 8 Document No.U085167 Date:Nov/20/2019 DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not covered by the following instructions, should be submitted to your contracted company. Include sketches and technical details, as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent, and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority having jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radially outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R) must be kept as few as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided for the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13, 13D and 13R for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D, 13R or 13 for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to the exposure of a heat source other than an actual fire. Available Sprinkler Temperature Ratings Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating Maximum Ambient Ceiling Temperature Temperature Rating of the Cover Plate Assembly Ordinary 162°F (72°C) 100°F (38°C) 140°F (60°C) Intermediate 175°F (79°C) 150°F (66°C) 140°F (60°C) 1) Intermediate 175°F (79°C) 150°F (66°C) 162°F (72°C) Intermediate 205°F (96°C) 150°F (66°C) 162°F (72°C) 1) Maximum ambient temperature for the Cover Plate Assembly is 100°F (38°C). Precautionary Warnings for Corrosive Environments Model RC-RES sprinklers should not be installed where they may be subjected to a corrosive environment including the following: (1) Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. (2) Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) – Solder Joint) Page:4 of 8 Document No.U085167 Date:Nov/20/2019 All residual flux must be removed from the interior and exterior of the copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and/or leakage in the sprinkler system. Hydraulic Design Criteria The minimum required sprinkler flow rates for systems designed to NFPA 13D or 13R are given in TABLE A as a function of temperature rating and the maximum allowable coverage area. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of “design sprinklers” as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: ・ The flow rates given in TABLE A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. ・ A minimum discharge of 0.1GPM/sq.ft. [4.07LPM/sq.m] over the “design area” comprised of the four most hydraulically demanding sprinklers for the actual coverage area being protected by the four sprinklers. TABLE A. NFPA 13D & 13R WET PIPE HYDRAULIC DESIGN CRITERIA for Model SS8464 For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R or 13 as applicable. Ordinary Temperature Rating 162°F (72°C) Intermediate Temperature Rating 175°F (79°C) Intermediate Temperature Rating 205°F (96°C) Maximum Coverage Area(a) Ft. × Ft. (m ×m) Maximum Spacing Ft. (m) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) 12×12 (3.7×3.7) 12 (3.7) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 14×14 (4.3×4.3) 14 (4.3) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 16×16 (4.9×4.9) 16 (4.9) 13 (49.2) 7.0 (0.48) ― ― 13 (49.2) 7.0 (0.48) 18×18 (5.5×5.5) 18 (5.5) 17 (64.4) 12.0 (0.83) ― ― 17 (64.4) 12.0 (0.83) 20×20 (6.1×6.1) 20 (6.1) 21 (79.5) 18.4 (1.27) ― ― 21 (79.5) 18.4 (1.27) Smooth Ceilings 3/8 to 7/8 Inches. Beamed Ceilings per NFPA 13D, 13R or 13 Installed in beam 3/8 to 7/8 inches below bottom of beam. Concealed 8 (2.4) (a) For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. Sprinkler Spacing Criteria The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. TABLE A) Page:5 of 8 Document No.U085167 Date:Nov/20/2019 INSTALLATION The Model RC-RES must be installed in accordance with the following instructions: NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to the sprinklers that could cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation. After the installation is completed, the Protective Cap must be removed to place the sprinkler in service. Use a torque of 7 to 14 ft·lbs (9.5 to 19.0 N·m) to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. Use only NR-H model wrench socket for installation of RC-RES sprinklers. Use of any other wrench or socket is prohibited and may cause damage to the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Do not rotate the Cap Remover RC to the left with force when placing the two hook arms into place. The installed sprinkler may become loosened, which may cause water leakage. Installing Procedure Step 1 The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inches (50.8mm) as shown in Figure 3. Step 2 With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Socket NR-H or Ratchet (3/8” drive) & Socket NR-H Combination (Ref. Figure 4). The teeth of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3 If desired, the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with a 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the “Vertical Adjustment” indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Step 4 Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just has contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot contact the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6. FIGURE 3. INSTALLATION FIGURE 4. RATCHET & SOCKET Page:6 of 8 Document No.U085167 Date:Nov/20/2019 FIGURE 5. PROTECTIVE CAP REMOVAL FIGURE 6. INSTALLATION (COVER PLATE ASSEMBLY) FIGURE 7. INSTALLATION (CORRECT and INCORRECT) Page:7 of 8 Document No.U085167 Date:Nov/20/2019 CARE AND MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-RES. NOTES Wet pipe sprinkler systems must be maintained at a minimum temperature of 40°F / 4°C to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of a fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non-factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities, and all affected parties by this action, and must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and/or water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler system to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must be kept in a cool and dry place. Automatic sprinklers must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units because of dropping, hitting, over-tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area, and the same or lower flow ratings (as indicated under TABLE A “Hydraulic Design Criteria”). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verify that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing of its compliance with this document, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. Limited Warranty For details of warranty, refer to Sales Contract. Page:8 of 8 Document No.U085167 Date:Nov/20/2019 ORDER PROCEDURE When placing an order, please contact a local distributor with the following information (Model Name, Temperature Rating and Finish). Sprinkler Model: RC-RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162°F (72°C) or 175°F (79°C) or 205°F (96°C)) Cover Plate Assembly 2-5/8 inch (φ68mm) or 3-1/4 inch (φ83mm) or 2-5/8 inch square (□68mm), Order Separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. Standard Finishes Custom Finishes White Ivory Beige Brown Black Nickel Copper Wood Grain Custom Color Custom Pattern 2-5/8" Round, 140°F ○ ○ - - - - - - ○ ○ 3-1/4" Round, 140°F ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 2-5/8" Square, 140°F ○ - - - - - - - ○ ○ 2-5/8" Round, 162°F ○ - - - - - - - ○ ○ 3-1/4" Round, 162°F ○ - - - - - - - ○ ○ Tools for Installation of Model RC-RES ・Socket NR-H For use with a 3/8” drive ratchet (not included) ・Socket NR-H Plastic For use with a 1/2” drive ratchet (not included) ・Cap Remover RC ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA Page 1 of 7 Form No. F_042815 18.10.11 Rev 18.2.P65 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. 1. DESCRIPTION The Viking Attic Upright VK696 is a specific application concealed space sprinkler that provides superior fire protection in combustible and non-combustible sloped attic spaces when used in conjunction with Viking’s model V-BB (Back to Back) and V-SD (Single Directional) specific application sprinklers. Installed in the upright position, with the deflector parallel to the roof, the Attic Upright used in combination with the model V-BB increases the allowable span from 60’ to 80’ (18,3 m to 24,4 m). Viking Attic Upright sprinklers can be installed with either steel or CPVC piping, and allow the use of CPVC to feed the protected space below the attic (CPVC allowed on wet pipe systems only). They are available in brass or with corrosion-resistant Electroless Nickel PTFE (ENT) coatings where salt water and other corrosive elements are a consideration. Viking Attic Upright sprinklers are cULus Listed with specific application guidelines for use as special sprinklers as defined by the National Fire Protection Association (NFPA), and are listed for specific pitch range 4:12 to 12:12. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV Refer to the Approval Chart on page 3. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 4.2 U.S. (57 metric*) * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4” (57 mm) Covered by the following U.S. Patent No.: 8,083,002 owned by Tyco. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Ordering Information: (Also refer to the current Viking price list.) To order the Attic Sprinkler, add the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, ENT = JN Temperature Suffix: E = 200 °F (93.3 °C) Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrench: Standard Wrench: Part No. 21475M/B Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A B. Twelve-head capacity: Part No. 01725A Replaces Form F_042815 Rev. 18.2 (Added P65 Warning.) Attic Upright Sprinkler VK696 NOTE: As of May 2018 all logos have been re- moved from the wrench boss. ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA Page 2 of 7 Form No. F_042815 18.10.11 Rev 18.2.P65 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. 4. INSTALLATION Refer to appropriate NFPA Installation Standards. NOTE: Precedence for allowing 4.2K sprinklers to be used on dry pipe systems utilizing corrosion-resistant or internally galva- nized steel pipe is based on paragraph 8.3.4.4 of NFPA 13 (2013 edition). 5. OPERATION During a fire condition, the heat sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern to extinguish or control the fire, and protect the piping in the interstitial space. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Attic Upright Specific Application Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Intermediate 200 °F (93.3 °C)150 °F (65°C)Green Sprinkler Finishes: Brass, ENT3 Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 cULus Listed as corrosion resistant. Figure 1: Standard Sprinkler Wrench Wrench Flat Protective Sprinkler Cap Figure 2: Sprinkler Dimensions 2-1/4” (57 mm) 7/16” (12 mm) Nominal Pipe Engagement (Dimensions are approximate) 1/2” (15 mm) NPT 1-1/4” (32 mm) ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA Page 3 of 7 Form No. F_042815 18.10.11 Rev 18.2.P65 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. APPROVAL CHART Attic Upright Specific Application Sprinkler VK696 For Combustible and Non-Combustible Sloped Attic Spaces Part Number1 SIN Maximum Pressure Thread Size Nominal K-Factor Overall Length Listings and Approvals3 NPT BSP U.S.metric2 Inches mm cULus4 FM LPCB 19538 VK696 175 psi 1/2”15 mm 4.2 57 2-1/4 57 A1, A2 -------- Approved Temperature Rating A - 200 °F (93.3 °C) Approved Finish 1 - Brass, 2 - ENT5 1 Also refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 4 Listed by Underwriters Laboratories Inc. for use in the United States and Canada. 5 cULus Listed as corrosion resistant. DESIGN CRITERIA - UL (Also refer to Approval Chart 1) Allowable Roof Span, Flow, Pressure and Slope for Specific Application Sprinkler Protecting Attics Sprinkler Base Part Number SIN Thread Size Nominal K-Factor Allowable Roof Span2 Ft. (M) Minimum Flow Minimum Pressure Pitch1 Dry Pipe System Maximum Water Delivery Time (in seconds)NPT BSP U.S.metric GPM LPM PSI BAR 19538 VK696 1/2”15 mm 4.2 57 10 (3,1) x 12 (3,6) Minimum 7 psi (0,48 Bar) Minimum 0.10 gpm/ft2 (4,1 mm/min.) Design Density 4:12 to 12:12 60 seconds (All System Sizes) NOTE: Precedence for allowing 4.2K sprinklers to be used on dry pipe systems utilizing corrosion-resistant or internally galvanized steel pipe is based on paragraph 8.3.4.4 of NFPA 13 (2013 edition). 1 Pitch and slope indicate the incline of a roof, expressed as a proportion of the vertical to the horizontal. 2The Attic Upright is measured along the slope maximum 10 ft. (3,1 m) perpendicular to slope by maximum 12 ft (3,6 m) parallel to slope. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of N FPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA Page 4 of 7 Form No. F_042815 18.10.11 Rev 18.2.P65 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. ADDITIONAL DESIGN CRITERIA - UL Chart 2 (Also refer to DESIGN CRITERA Chart 1) Allowable roof span, flow, pressure and slope for attic protection using Viking V-SD Sprinklers Design Criteria: Flow and Pressures refer to Design Chart 1. System Type: Wet systems and dry systems. Piping Types: Steel (wet and dry) CPVC (wet systems only). Occupancy Classification: Light hazard only. Viking Attic Upright Sprinkler Spacing Maximum Coverage Area: 120 ft2 (11,2 m2) Minimum Spacing: 7’-0” (2,1 m) from Attic Upright Sprinklers, V-BB Sprinklers, V-SD Sprinklers, and Standard Spray Sprinklers, when measured along the peak/ridge direction. 26’-0” (7,9 m) from Viking V-BB and V-SD Sprinklers when measured down the slope. Maximum Spacing: 10’-0” (3,1 m) when measured perpendicular to the slope. 12’-0” (3,7 m) when measured parallel to the slope. Additional Spacing Considerations: If there is more than one row of Attic Upright Sprinklers, they must be staggered as shown in Figure 3. Attic Upright Sprinklers can provide up to 10’-0” (3,1 m) coverage at the eave(s) beyond the maximum allowable roof spans for the V-BB and V-SD Sprinklers by installing a row of Attic Uprights. Refer to Figure 4 and 5 for installation criteria in these situations. Deflector Position: Deflector located 1”– 3” (26 - 77 mm) below the bottom of the top chord or bottom of solid wood rafter for all roof pitches as per the listing from 4:12 – 12:12, with a maximum top chord or solid wood rafter depth of 12” (305 mm). Use of UL Listed CPVC Blazemaster Piping (Wet Systems Only): Can be used to supply the sprinklers protecting the floor below the combustible concealed space when covered with 6” (153 mm) of non-combustible insulation over the horizontal or vertical piping, and extending 12” (305 mm) on both sides of the center line of the piping. If the piping is located in the joist, the width of the joist channel must be entirely covered to 6” above the top of the piping. The area above the piping must be protected with the Viking Model V-BB’s, V-SD’s, or the Attic Upright Sprinklers. Listed CPVC Blazemaster piping may also be used exposed to provide wet system, vertical or angled, sprigs to Attic Upright Sprinklers where: • The exposed portion of an angled sprig is a maximum length of 3’-0” (0,9 m), with the sprig being supported adjacent to the Attic Upright Sprinkler, and vertical restraint is provided on the horizontal pipe runs with CPVC hangers. • Maximum exposed length on a sprig of 10’-0” (3,1 m), with a maximum lateral distance for the Attic Upright Sprinkler of 12” (305 mm) off of the centerline of the sprig. Sprig must also be supported at the swing joint to the Attic Upright Sprinkler. • Minimum 6” (153 mm) deep of non-combustible insulation extending 12” (305 mm) on each side of the pipe centerline for the CPVC branchline feeding the Attic Upright Sprinklers. • If the CPVC branchline is installed inside the ceiling joist, the joist channel must be covered or filled with a minimum of 6” (153 mm) deep non-combustible insulation on top of the branchline feeding the Attic Upright Sprinkler sprigs. • Additional non-combustible insulation can be added to reduce the exposed length of the sprigs being used with the Attic Upright Sprinklers. • Installed with a minimum lateral distance of 18” (458 mm) from any device that produces and releases heat, i.e Attic furnace, Kitchen or Bathroom Exhaust fan, Flue Vents, Heat Lamps, and other such devices. Continues on next page. ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA Page 5 of 7 Form No. F_042815 18.10.11 Rev 18.2.P65 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Continued from previous page. Insulation requirements are provided solely for Fire Protection purposes and not for freeze protection. Non-combustible insulation being used needs to be verified for chemical compatibility with the CPVC piping at www.lubrizol.com Obstruction Criteria: Refer to Figures 6 and 7. Refer to Sections 8.8.5.2.1.3 and 8.8.5.2.1.7 of NFPA 13, 2013 for requirements if installed on greater than 2-1/2” diameter piping. Hydraulic Requirements: Minimum Design pressure: 7 psi Minimum design density: 0.10 gpm/sq. ft. For individual areas requiring more than four Attic Upright Sprinklers, the maximum area of the attic protected by Attic Upright Sprinklers is 3,000 ft (279 m2) in any single area. In order to be considered a single area, the areas protected by the Attic Upright Sprinklers must be separated by a minimum of 15’-0” (4,6 m), having that separation being protected by V-BB or V-SD sprinklers. The design area shall include the most hydraulically demanding sprinklers, and in certain cases may require more than one set of calculations to verify the systems design. Refer to the Technical Data Sheets for the Model V-BB (Form No. F_042915) and V-SD (Form No. F_043015) Specific Application Attic Sprinklers for more information regarding hydraulic requirements of Attic Upright Sprinklers. V-BB (Back to Back) To p Side Top Side V-SD (Single Directional) Top Side Attic Upright ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA Page 6 of 7 Form No. F_042815 18.10.11 Rev 18.2.P65 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Figure 4: Model V-BB Spinklers Combined with Attic Upright Sprinklers Covering Over 60 to 80 ft. Span Figure 5: Model V-SD Spinklers Combined with Attic Upright Sprinklers V-BB Coverage V-BB 10’ (3,05 m) Maximum Attic Upright Coverage 6’ (1,83 m) Maximum Over 60 - 80ft (18,3 - 24,4 m) 6’ (1,83 m) Maximum 4’ (1,22 m) Minimum Refer to Figures 4 and 5 below. For attics having a span of 60 - 80 ft. (18,3 - 24,4 m), only the 8.0K model V-BB sprinklers combined with Attic Upright Sprinklers can be used. For attics with a span of over 80’ (24,4 m), Standard Spray Spinklers must be used. In an attic using single ridge construction, 8.0K model V-BB sprinklers must be used to protect the center portion. Attic Upright sprinklers should be used to cover up to 10 feet (3,1 m) at the eaves beyond the maximum 60 ft. (18,3) span covered by the model V-BB Sprinklers. Refer to the Technical Data Sheets for the model V-BB and V-SD sprinklers for more information. Attic Upright sprinklers spaced 7’ - 8’ (1,8 - 2,4 m) on centers 10’ (3,05 m) Maximum Attic Upright Coverage 6’ (1,83 m) Maximum 6’ (1,83 m) Maximum 4’ (1,22 m) Minimum V-SD Coverage V-SD 60’ (18,3 m) roof span15’ (4,6 m) Minimum Spacing must be staggered for additional rows Region 1: Attic Upright Sprinklers Region 3: Attic Upright Sprinklers Region 2: V-BB Sprinklers Figure 3: Attic Upright Sprinklers Combined with V-BB Sprinklers When the total number of Attic Upright Sprinklers at the hip is greater than 4: Wet Systems: Calculate the most demanding 5 model V-BB Sprinklers, add the most demanding 2 Attic Upright Sprinklers, then calculate the most demanding region up to 1500 ft2 (137 m2) that uses Attic Upright Sprinklers (example: Region 1 at right). Use the most demanding calculation. Dry Systems: Calculate the most demanding 7 model V-BB sprinklers, add the most demanding 2 Attic Upright Sprinklers, then calculate the most demanding region up to 1950 ft2, (181 m2) that uses Attic Upright Sprinklers (example: Region 1 at right). Use the most demanding calculation. ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA Page 7 of 7 Form No. F_042815 18.10.11 Rev 18.2.P65 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Figure 6: Attic Upright Obstruction Criteria 1 Figure 7: Attic Upright Obstruction Criteria 2 X ELEVATION VIEW PLAN VIEW XZ Y Y Z W X Refer to Figure 6 below. Requirements: X ≥ 3Y or 3Z, X ≤ 24” (610 mm); Use the larger dimension Y or Z. TABLE 2: ATTIC UPRIGHT OBSTRUCTION CRITERIA Horizontal Distance (X)Minimum Vertical Distance Below Deflector (W) ≤6” (≤152 mm) 3” (77 mm) >6” - 9” (>152 - 229 mm) 4” (102 mm) >9” - 12” (>229 - 305 mm) 6” (89 mm) >12” - 15” (>305 - 381 mm) 8” (204 mm) >15” - 18” (>381 - 458 mm) 9-1/2” (242 mm) >18” - 24” (>458 - 610 mm) 12-1/2” (318 mm) >24” - 30” (>610 - 762 mm) 15-1/2” (394 mm) >30” (762 mm) 18” (458 mm) Replaces Form F_042815 Rev. 18.2 (Added P65 Warning.) FIRE SPRINKLERS – FIRE ALARMS – FIRE EXTINGUISHERS – EMERGENCY LIGHTING – SAFETY & FIRST AID SUPPLIES Page 4 of 7 6438 Arville St. Las Vegas, NV 89118 (702) 966-8021 Tel (702) 987-1174 Fax www.onguardfp.com License #: NV-61307 CA-950378 Bid Limit $4.5 M 3. PIPE & FITTINGS Trusted above all ™ Features • Sizes Available (Nominal): 3/4” (DN20) through 3” (DN80) pipe diameters, with a Standard Dimension Ratio (SDR) of 13.5 as specified in ASTM F442. • Environmental Specifications: Indoor use only. Maximum Ambient Temperature: 150°F (65°C) • Hazen-Williams C Value: 150 • Pressure Data: Working Pressure: 175 PSI (12.1 bar) at 150°F (65°C) • Specifications: • Meets NFPA 13R and 13D standards for residential occupancies as well as NFPA 13 standards for light hazard occupancies. • Pipe meets or exceeds ASTM F442. • Certified by NSF International for potable water services. • CPVC pipe from Viking Plastics use compound cell class 23547 (demonstrated highest structural properties). • cULus Listed, FM Approved, New York City (MEA) Approved, LPCB Approved. CPVC PIPE PHYSICAL DATA Nominal Pipe Size Actual Outside Diameter Average Inside Diameter *Weight per 15’ (4,6 m) length Length Approvals Part Number Inch DN Inch mm Inch mm Lb.Kg.Feet M 3/4”DN20 1.050 26,670 0.874 22,199 2.52 1,14 15 4.6 cULus, FM, NSF 34PIPE 1”DN25 1.315 33,401 1.101 27,965 3.93 1,78 15 4.6 1PIPE 1 1/4”DN32 1.660 42,164 1.394 35,408 6.27 2,84 15 4.6 114PIPE 1 1/2”DN40 1.900 48,260 1.598 40,589 8.22 3,73 15 4.6 112PIPE 2”DN50 2.375 60,325 2.003 50,876 12.89 5,85 15 4.6 2PIPE 2 1/2”DN65 2.875 73,000 2.423 61,500 18.86 8,55 15 4.6 212PIPE 3”DN80 3.500 88,900 2.950 74,900 28.01 12,71 15 4.6 3PIPE Nominal Pipe Size Actual Outside Diameter Average Inside Diameter *Weight per 10’ (3,05 m) length Length Approvals Part Number Inch DN Inch mm Inch mm Lb.Kg.Feet M 3/4”DN20 1.050 26,670 0.874 22,199 1.68 0,76 10 3,05 cULus, FM, NSF 34PIPE10 1”DN25 1.315 33,401 1.101 27,965 2.62 1,19 10 3,05 1PIPE10 1 1/4”DN32 1.660 42,164 1.394 35,408 4.18 1,90 10 3,05 114PIPE10 1 1/2”DN40 1.900 48,260 1.598 40,589 5.48 2,49 10 3,05 112PIPE10 2”DN50 2.375 60,325 2.003 50,876 8.59 3,90 10 3,05 2PIPE10 2 1/2”DN65 2.875 73,000 2.423 61,500 12.57 5,70 10 3,05 212PIPE10 3”DN80 3.500 88,900 2.950 74,900 18.67 8,47 10 3,05 3PIPE10 NOTE: CPVC Pipe is produced in SDR 13.5 Dimensions in accordance with ASTM F442. Standard Dimension Ratio is the ratio of the outside pipe diameter to the wall thickness of the pipe. Blazemaster® is a registered trademark of Lubrizol. Specifications subject to change without notice *Empty pipe weights IMPORTANT: Installers should receive thorough hands-on training in the proper methods of assembly and installation of CPVC products. Trusted above all ™ CPVC Pipe Product Specifications Corrosion resistant CPVC fire sprinkler pipe, when installed in strict accordance with the manufacturer’s design and instal- lation instructions, is UL and c-UL Listed by Underwriters Laboratories for use in the following: Meets NFPA 13R and 13D standards for residential occupancies as well as NFPA 13 standards for light hazard occupancies. Residential occupancies up to and including four stories in height as defined by NFPA 13R. Residential occupancies as defined in the Standard for Sprinkler Systems in One and Two Family Dwellings, NFPA 13D. Installation of private fire service mains and their appurtenances, NFPA 24. CPVC fire sprinkler pipe from Viking Plastics shall be employed in wet pipe systems only and are not listed for outdoor use. CPVC pipe must never be used in a system using compressed air or other gases. • • • • CPVC pipe from Viking Plastics also carries the follow- ing enhanced listings and approvals: According to UL Listing Can be flush at return air plenums Exposed system risers NFPA 13D, 13R Exposed basement NFPA 13D (solid wood joist) Extended coverage (exposed) 20’ spacing on pendent in lieu of 15’ 18’ spacing on sidewall in lieu of 14’ Use with combustible concealed sprinklers Tyco attic sprinkler head (to protect the floor below) Tyco attic sprinkler head with wet system piping (feed main and ridge installation) • • • • •   • • • Exposed sidewall sprinkler listing for exposed pipe & fittings 24’ extended coverage sidewall sprinkler, 12” drop, 155°F sprinkler head 18’ extended coverage sidewall sprinkler, 12” drop, 165°F sprinkler head 16’ extended coverage sidewall sprinkler, 12” drop, 175°F sprinkler head 14’ standard coverage sidewall sprinkler, 12” drop, 200°F sprinkler head Factory Mutual Approved* Factory Mutual Approval exposed Factory Mutual Approval above drop-in ceilings Factory Mutual Approval exposed w/Soffi-Steel soffiting covering system •     • • • • New and enhanced listings and approvals are being pursued. Always check with the appropriate Listing and Approval agency for details on current listing parameters. CPVC pipe meets all applicable standards for pressure rated applica- tion as required in ANSI-NSF Standard 14 and complies with ANSI-NSF Standard 61 for health effects and are marked with the NSF-pw end use marking. All CPVC fire sprinkler pipe shall be Listed by Underwriters Laboratories for wet pipe systems, and shall carry a rated working pressure of 175 psi @ 150°F (12 bar @ 65.5°C). *The FM Approval is limited to use in wet pipe fire protection sprinkler systems for light hazard occupancies in both concealed and exposed applications with certain restrictions. Piping must always be installed in strict accordance to the manufacturer’s DESIGN AND INSTALLATION GUIDE, including product storage and handling, joining methods, supporting and bracing, expansion and con- traction allowance and testing, etc. National Fire Protection Association (NFPA) Standards 13, 13D, and 13R must be referenced for design and installation requirements in conjunction with the installation instructions. All CPVC fire sprinkler pipe from Viking Plastics is manufactured in the USA. All CPVC pipe shall be packaged immediately after its manufacture to prevent damage and shall be stored indoors after production, at the manufacturing site, until shipped from the factory. The pipe shall bear the logo of the listing agencies, and shall carry the National Sanitation Foun- dation (NSF) seal of approval for potable water applications. CPVC products are intended for use in areas where the maximum ambi- ent temperature does not exceed 150°F (65.5°C). If the ambient tempera- ture is expected to exceed this limitation, refer to the manufacturer’s DE- SIGN AND INSTALLATION GUIDE for additional information on methods to reduce the pipe exposure temperatures. CPVC pipe is not intended to be installed in outdoor applications. CPVC pipe is intended to be used in wet pipe systems only and have not been investigated for use in dry pipe systems. Special installation and design criteria relative to pipe hanger spacings, piping and sprinkler restraint, sprinkler temperature rating, piping locations, testing procedures and friction loss characteristics are specified in the manufacturer’s installation instructions provided with the pipe. The manufacturer’s installation instructions should be reviewed and the Authority Having Jurisdiction consulted before installation. Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com BlazeMaster® CPVC Pipe • Sizes Available (Nominal) : 3/4” (DN20) through 3” (DN80) pipe diameters, with a Standard Dimension Ratio (SDR) of 13.5 as specified in ASTM F442. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Hazen-Williams C Value : 150 • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : - Meets NFPA 13, 13R and 13D standards for light hazard occupancies. Pipe meets or exceeds ASTM F442. - Approved for National Sanitation Foundation (NSF) potable water services - CPVC Pipe from Viking SupplyNet complies to NSF cell class 23547 (demonstrated highest structural properties). - Meets LPC Sprinkler Rules requirements Technical Features Nominal Pipe Size Actual Outside Diameter Average I.D. (inch / mm) Weight per 15’ (4.6m) length (lb / kg) Length (ft / m)Approvals Part Numberinchmetricinchmm 3/4” DN20 1.050 26,670 0.874 / 22,199 2.52 / 1,14 15 / 4,6 cULus, FM, LPCB*, WRAS, NSF 34PIPE 1” DN25 1.315 33,401 1.101 / 27,965 3.93 / 1,78 15 / 4,6 1PIPE 11/4” DN32 1.660 42,164 1.394 / 35,408 6.27 / 2,84 15 / 4,6 114PIPE 11/2” DN40 1.900 48,260 1.598 / 40,589 8.22 / 3,73 15 / 4,6 112PIPE 2” DN50 2.375 60,325 2.003 / 50,876 12.89 / 5,85 15 / 4,6 2PIPE 21/2” DN65 2.875 73,000 2.423 / 61,500 18.86 / 8,55 15 / 4,6 212PIPE 3”DN80 3.500 88,900 2.950 / 74,900 28.01 / 12,71 15 / 4,6 3PIPE Nominal Pipe Size Actual Outside Diameter Average I.D. (inch / mm) Weight per 10’ (3,05m) length (lb / kg) Length (ft / m)Approvals Part Numberinchmetricinchmm 3/4” DN20 1.050 26,670 0.874 / 22,199 1.68 / 0,76 10 / 3,05 cULus, FM, LPCB*, WRAS, NSF 34PIPE10 1” DN25 1.315 33,401 1.101 / 27,965 2.62 / 1,19 10 / 3,05 1PIPE10 11/4” DN32 1.660 42,164 1.394 / 35,408 4.18 / 1,90 10 / 3,05 114PIPE10 11/2” DN40 1.900 48,260 1.598 / 40,589 5.48 / 2,49 10 / 3,05 112PIPE10 2” DN50 2.375 60,325 2.003 / 50,876 8.59 / 3.90 10 / 3,05 2PIPE10 21/2” DN65 2.875 73,000 2.423 / 61,500 12.57 / 5,70 10 / 3,05 212PIPE10 3”DN80 3.500 88,900 2.950 / 74,900 18.67 / 8,47 10 / 3,05 3PIPE10 Note: CPVC Pipe is produced in SDR 13.5 Dimensions in accordance with ASTM F442. Standard Dimension Ratio is the ratio of the outside pipe diameter to the wall thickness of the pipe. * Approved up to and includng 2” BlazeMaster® CPVC Pipe Physical Data BlazeMaster® is manufactured for Viking SupplyNet by Viking Plastics, Inc. Refer to Manufacturer’s datasheet. Specifications subject to change without notice. IMPORTANT: Installers should receive thorough hands-on training in the proper methods of assembly and installation of CPVC products. On-site training is available at no charge from Viking SupplyNet. Participants in the training program will receive a special card acknowledging their attendance. In addition to receiving proper training, installers must always consult the Manufacturer’s Design and Installation Guide before any installation project is commenced. *21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com BlazeMaster® CPVC Pipe BlazeMaster® CPVC Pipe Product Specifications Corrosion resistance CPVC fire sprinkler pipe, when installed in strict accordance with the manufacturer’s design and installation instructions, are UL and C-UL Listed by Underwriters Laboratories for use in the following: • Light Hazard occupancies as defined in the Standard for Installation of Sprinkler Systems, NFPA 13. • Residential occupancies up to and including four stories in height as defined by NFPA 13R. • Residential occupancies as defined in the Standard for Sprinkler Systems in One and Two Family Dwellings, NFPA13D. • Installation of private fire service mains and their appurtenances, NFPA 24. CPVC fire sprinkler pipe from Viking SupplyNet shall be employed in wet pipe systems only and are not listed for outdoor use. CPVC pipe must never be used in a system using compressed air or other gases. CPVC pipe from Viking SupplyNet also carries the following enhanced listings and approvals: • According to UL Listed (UL 1821) • Can be flush at return air plenums • Mechanical cut-in tee & crosses concealed with Grinnell figure 730 fittings • Mechanical cut-in tee & crosses exposed with Grinnell figure 730 fittings • Exposed system risers NFPA 13D, 13R • Exposed basement NFPA 13D (solid wood joist) • Extended coverage (exposed) • 20’ spacing on pendent in lieu of 15’ • 18’ spacing on sidewall in lieu of 14’ • Use with combustible concealed sprinklers • Tyco attic sprinkler head (to protect the floor below) • Tyco attic sprinkler head with wet system piping (feed main and ridge installation) • Exposed sidewall sprinkler Listing for exposed pipe & fittings • 24’ extended coverage sidewall sprinkler, 12” drop, 155°F sprinkler head • 18’ extended coverage sidewall sprinkler, 12” drop, 165°F sprinkler head • 16’ extended coverage sidewall sprinkler, 12” drop, 175°F sprinkler head • 14’ standard coverage sidewall sprinkler, 12” drop, 200°F sprinkler head • Factory Mutual Approved* • Factory Mutual Approval exposed • Factory Mutual Approval above drop-in ceilings • Factory Mutual Approval exposed w/ Soffi-Steel soffiting covering system • LPCB Approval • WRAS Approval The above data is based on UL and FM reported Listings and Approvals as of 11/30/05. New and enhanced listings and approvals are being pursued. Always check with the appropriate Listing and Approval agency for details on current listing parameters. CPVC pipe also meets all applicable standards for pressure rated application as required in ANSI-NSF Standard 14 and complies with ANSI-NSF Standard 61 for health effects and are marked with the NSF-pw end us marking. Viking Plastics CPVC Pipe is manufactured from WRAS approved Blazemaster® compound All CPVC fire sprinkler pipe shall be Listed by Underwriters Laboratories for wet pipe systems, and shall carry a rated working pressure of 175 psi @ 150ºF (12 bar @ 66°C). The FM Approval is limited to use in wet pipe fire protection sprinkler systems for light hazard occupancies in both concealed and exposed applications with certain restrictions. Piping must always be installed in strict accordance to the manufacturer’s System Design and Installation Manual, including product stor- age and handling, joining methods, supporting and bracing, expansion and contraction allowance and testing, etc. National Fire Protection Association (NFPA) Standards 13, 13D, and 13R or LPC Sprinkler Rules Technical Bulletins, must be referenced for design and installation requirements in conjunction with the installation instructions. All CPVC fire sprinkler pipe from Viking SupplyNet is manufactured in the USA by an ISO 9001 certified manufacturer. All CPVC pipe shall be packaged immediately after its manufacture to prevent damage and shall be stored indoors after production, at the manufactur- ing site, until shipped from the factory. The pipe shall bear the logo of the listing agencies, and shall carry the National Sanitation Founda- tion (NSF) seal of approval for potable water applications. CPVC products are intended for use in areas where the maximum ambient temperature does not exceed 150ºF (66°C). If the ambi- ent temperature is expected to exceed this limitation, refer to the manufacturer’s System Design and Installation Manual for additional information on methods to reduce the pipe exposure temperatures. CPVC pipe is not intended to be installed in outdoor applications. CPVC pipe is intended to beused in wet pipe systems only and have not been investigated for use in dry pipe systems. Special installation and design criteria relative to pipe hanger spacings, piping and sprinkler restraint, sprinkler temperature rating, piping locations, testing procedures and friction loss characteristics are specified in the manufacturer’s installation instructions provided with the pipe. The manu- facturer’s installation instructions should be reviewed and the Authority Having Jurisdiction consulted before installation. BlazeMaster® is manufactured for Viking SupplyNet by Viking Plastics, Inc. Refer to Manufacturer’s datasheet. Specifications subject to change without notice.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings) Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com Reducing Tee Socket x Socket x Socket • Sizes Available (Nominal) : See table below. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricABC 3/4” x 3/4” x 1”DN20 x DN20 x DN25 / 0.70 / 0.70 / 0.73 0.15 / 0.068 V5011R-102 1” x 3/4” x 3/4”DN25 x DN20 x DN20 / 0.74 / 0.80 / 0.84 0.15 / 0.068 V5011R-125 1” x 3/4” x 1”DN25 x DN20 x DN25 / 0.74 / 0.91 / 0.73 0.22 / 0.100 V5011R-126 1” x 1” x 3/4”DN25 x DN25 x DN20 / 0.61 / 0.61 / 0.94 0.13 / 0.059 V5011R-131 11/4” x 1” x 3/4”DN32 x DN25 x DN20 / 0.74 / 0.60 / 0.89 0.20 / 0.091 V5011R-157 11/4” x 1” x 1”DN32 x DN25 x DN25 / 0.90 / 0.71 / 0.89 0.24 / 0.110 V5011R-158 11/4” x 1” x 11/4”DN32 x DN25 x DN32 / 1.00 / 0.91 / 0.87 0.28 / 0.130 V5011R-159 11/4” x 11/4” x 3/4”DN32 x DN32 x DN20 / 0.60 / 0.60 / 0.89 0.21 / 0.095 V5011R-167 11/4” x 11/4” x 1”DN32 x DN32 x DN25 / 0.72 / 0.72 / 0.89 0.13 / 0.059 V5011R-168 11/4” x 11/4” x 11/2”DN32 x DN32 x DN40 / 1.00 / 1.00 / 0.88 0.42 / 0.191 V5011R-169 11/2” x 11/4” x 3/4”DN40 x DN32 x DN20 / 0.76 / 0.62 / 1.02 0.35 / 0.159 V5011R-201 11/2” x 11/4” x 1”DN40 x DN32 x DN25 / 0.88 / 0.74 / 1.01 0.39 / 0.177 V5011R-202 11/2” x 11/2” x 3/4”DN40 x DN40 x DN20 / 0.76 / 0.76 / 1.31 0.48 / 0.172 V5011R-210 11/2” x 11/2” x 1”DN40 x DN40 x DN25 / 0.77 / 0.77 / 1.29 0.52 / 0.236 V5011R-211 11/2” x 11/2” x 11/4”DN40 x DN40 x DN32 / 0.87 / 0.87 / 1.04 0.47 / 0.213 V5011R-212 11/2” x 11/2” x 2”DN40 x DN40 x DN50 / 1.30 / 1.29 / 1.14 0.67 / 0.304 V5011R-213 2” x 2” x 3/4”DN50 x DN50 x DN20 / 0.67 / 0.67 / 1.56 0.65 / 0.295 V5011R-248 2” x 2” x 1”DN50 x DN50 x DN25 / 0.77 / 0.77 / 1.55 0.69 / 0.313 V5011R-249 2” x 2” x 11/2”DN50 x DN50 x DN40 / 1.04 / 1.04 / 1.29 0.83 / 0.376 V5011R-251 21/2” x 21/2” x 1”DN65 x DN65 x DN25 / 1.53 / 1.53 / 2.59 1.87 / 0.848 V5011R-289 21/2” x 21/2” x 11/4”DN65 x DN65 x DN32 / 1.53 / 1.53 / 2.47 1.90 / 0.862 V5011R-290 21/2” x 21/2” x 11/2”DN65 x DN65 x DN40 / 1.53 / 1.53 / 2.08 1.86 / 0.844 V5011R-291 3” x 3” x 2”DN80 x DN80 x DN50 / 1.34 / 1.34 / 1.82 1.73 / 0.785 V5011R-338 3” x 3” x 21/2”DN80 x DN80 x DN65 / 1.84 / 1.84 / 2.55 2.90 / 1.320 V5011R-339 Refer to the “CPVC Equal Tee” datapage or manufacturer’s installation instructions for friction loss information. Reducing Tee - Socket x Socket x Socket Physical Data A B C Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice. * * LPCB Approved up to and including 2” ** Approval pending.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com Equal Tee Socket x Socket x Socket • Sizes Available (Nominal) : 3/4” (DN20) through 3” (DN80) pipe diameters. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricABC 3/4”DN20 / 0.56 / 0.56 / 0.56 0.09 / 0.04 V5011-007 1”DN25 / 0.69 / 0.69 / 0.69 0.15 / 0.07 V5011-010 11/4”DN32 / 0.89 / 0.89 / 0.89 0.30 / 0.14 V5011-012 11/2”DN40 / 1.06 / 1.06 / 1.06 0.73 / 0.33 V5011-015 2”DN50 / 1.27 / 1.27 / 1.27 1.05 / 0.48 V5011-020 21/2”DN65 / 1.53 / 1.53 / 1.53 1.59 / 0.72 V5011-025 3”DN80 / 1.84 / 1.84 / 1.84 2.38 / 1.10 V5011-030 Equal Tee - Socket x Socket x Socket Physical Data A B C Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice. Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4”DN20 1 / 0.3 3 / 0.9 7 / 2.1 1 / 0.3 1 / 0.3 1”DN25 1 / 0.3 5 / 1.5 7 / 2.1 1 / 0.3 1 / 0.3 11/4”DN32 1 / 0.3 6 / 1.8 8 / 2.4 2 / 0.6 1 / 0.3 11/2”DN40 1 / 0.3 8 / 2.4 9 / 2.7 2 / 0.6 1 / 0.3 2”DN50 1 / 0.3 10 / 3.1 11 / 3.4 2 / 0.6 1 / 0.3 21/2”DN65 2 / 0.6 12 / 3.7 12 / 3.7 3 / 0.9 2 / 0.6 3”DN80 2 / 0.6 15 / 4.6 13 / 4.0 4 / 1.2 2 / 0.6 CPVC Fittings Allowances for Friction Loss in Fittings 21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” ** Approval pending. *** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com Sprinkler Head Tee (Metal Thread Insert) Socket x Socket x NPT Thread • Sizes Available (Nominal) : See table below. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Threaded Connections : 1 female threaded NPT outlet. • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.5 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricABC 3/4” x 3/4” x 1/2”DN20 x DN20 x DN15 / 0.42 / 0.42 / 1.60 0.22 / 0.100 V5012SBI-101 1” x 3/4” x 1/2”DN25 x DN20 x DN15 / 0.43 / 0.83 / 1.69 0.27 / 0.125 V5012RSBI-124 1” x 1” x 1/2”DN25 x DN25 x DN15 / 0.42 / 0.42 / 1.76 0.28 / 0.127 V5012SBI-130 1” x 1” x 1”DN25 x DN25 x DN25 / 0.83 / 0.83 / 1.48 0.43 / 0.195 V5012SBI-010 11/4” x 1” x 1/2”DN32 x DN25 x DN15 / 0.51 / 0.63 / 1.94 0.33 / 0.149 V5012RSBI-156 11/4” x 11/4” x 1/2”DN32 x DN32 x DN15 / 0.51 / 0.51 / 1.95 0.33 / 0.149 V5012SBI-166 11/2” x 11/4” x 1/2”DN40 x DN32 x DN15 / 0.45 / 0.67 / 2.13 0.47 / 0.213 V5012RSBI-199 11/2” x 11/2” x 1/2”DN40 x DN40 x DN15 / 0.45 / 0.45 / 2.13 0.47 / 0.213 V5012SBI-209 2” x 11/2” x 1/2”DN50 x DN40 x DN15 / 0.62 / 0.82 / 2.38 0.58 / 0.263 V5012RSBI-237 2” x 2” x 1/2”DN50 x DN50 x DN15 / 0.50 / 0.50 / 1.68 0.58 / 0.263 V5012SBI-247 Sprinkler Head Tee (Metal Thread Insert) - Socket x Socket x NPT Thread Physical Data Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4”DN20 1 / 0.3 3 / 0.9 7 / 2.1 1 / 0.3 1 / 0.3 1”DN25 1 / 0.3 5 / 1.5 7 / 2.1 1 / 0.3 1 / 0.3 11/4”DN32 1 / 0.3 6 / 1.8 8 / 2.4 2 / 0.6 1 / 0.3 11/2”DN40 1 / 0.3 8 / 2.4 9 / 2.7 2 / 0.6 1 / 0.3 2”DN50 1 / 0.3 10 / 3.1 11 / 3.4 2 / 0.6 1 / 0.3 21/2”DN65 2 / 0.6 12 / 3.7 12 / 3.7 3 / 0.9 2 / 0.6 3”DN80 2 / 0.6 15 / 4.6 13 / 4.0 4 / 1.2 2 / 0.6 CPVC Fittings Allowances for Friction Loss in Fittings Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” ** Approval pending. *** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com Sprinkler Head Tee (Metal Thread Insert) Socket x NPT Thread x Socket • Sizes Available (Nominal) : 1” (DN25) x 1/2” (DN15) x 1” (DN25) • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Threaded Connections : 1 female threaded NPT outlet. • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricABC 1” x 1/2” x 1”DN25 x DN15 x DN25 ///0.25 / 0.113 V5012RSBI-122 Sprinkler Head Tee (Metal Thread Insert) - Socket x NPT Thread x Socket Physical Data Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4”DN20 1 / 0.3 3 / 0.9 7 / 2.1 1 / 0.3 1 / 0.3 1”DN25 1 / 0.3 5 / 1.5 7 / 2.1 1 / 0.3 1 / 0.3 11/4”DN32 1 / 0.3 6 / 1.8 8 / 2.4 2 / 0.6 1 / 0.3 11/2”DN40 1 / 0.3 8 / 2.4 9 / 2.7 2 / 0.6 1 / 0.3 2”DN50 1 / 0.3 10 / 3.1 11 / 3.4 2 / 0.6 1 / 0.3 21/2”DN65 2 / 0.6 12 / 3.7 12 / 3.7 3 / 0.9 2 / 0.6 3”DN80 2 / 0.6 15 / 4.6 13 / 4.0 4 / 1.2 2 / 0.6 CPVC Fittings Allowances for Friction Loss in Fittings Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” ** Approval pending. *** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com Sprinkler Head Tee - Sidewall (Metal Thread Inserts) NPT Thread x NPT Thread x Socket • Sizes Available (Nominal) : 1/2” (DN15) pipe run with 1” (DN25) outlet. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Threaded Connections : 2 female threaded NPT inlets. • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricABC 1/2” x 1/2” x 1”DN15 x DN15 x DN25 / 1.18 / 1.18 / 0.62 0.48 / 0.217 V501133SBIS-075 Sprinkler Head Tee - Sidewall (Metal Thread Inserts) - NPT x NPT x Socket Physical Data Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4”DN20 1 / 0.3 3 / 0.9 7 / 2.1 1 / 0.3 1 / 0.3 1”DN25 1 / 0.3 5 / 1.5 7 / 2.1 1 / 0.3 1 / 0.3 11/4”DN32 1 / 0.3 6 / 1.8 8 / 2.4 2 / 0.6 1 / 0.3 11/2”DN40 1 / 0.3 8 / 2.4 9 / 2.7 2 / 0.6 1 / 0.3 2”DN50 1 / 0.3 10 / 3.1 11 / 3.4 2 / 0.6 1 / 0.3 21/2”DN65 2 / 0.6 12 / 3.7 12 / 3.7 3 / 0.9 2 / 0.6 3”DN80 2 / 0.6 15 / 4.6 13 / 4.0 4 / 1.2 2 / 0.6 CPVC Fittings Allowances for Friction Loss in Fittings Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” ** Approval pending. *** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com A B 90° Elbow & Reducing 90° Elbow Socket x Socket • Sizes Available (Nominal) : See tables below. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricAB 1” x 3/4”DN25 x DN32 / 0.61 / 0.75 0.12 / 0.045 V5007R-131 Reducing 90° Elbow - Socket x Socket Physical Data B A Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricAB 3/4”DN20 / 0.56 / 0.56 0.06 / 0.022 V5007-007 1”DN25 / 0.69 / 0.69 0.09 / 0.034 V5007-010 11/4”DN32 / 0.91 / 0.91 0.16 / 0.059 V5007-012 11/2”DN40 / 1.06 / 1.06 0.50 / 0.187 V5007-015 2”DN50 / 1.24 / 1.24 0.70 / 0.261 V5007-020 21/2”DN65 / 1.50 / 1.50 1.16 / 0.433 V5007-025 3”DN80 / 1.81 / 1.81 1.82 / 0.679 V5007-030 90° Elbow - Socket x Socket Physical Data ELBOW REDUCING ELBOW Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4”DN20 1 / 0.3 3 / 0.9 7 / 2.1 1 / 0.3 1 / 0.3 1”DN25 1 / 0.3 5 / 1.5 7 / 2.1 1 / 0.3 1 / 0.3 11/4”DN32 1 / 0.3 6 / 1.8 8 / 2.4 2 / 0.6 1 / 0.3 11/2”DN40 1 / 0.3 8 / 2.4 9 / 2.7 2 / 0.6 1 / 0.3 2”DN50 1 / 0.3 10 / 3.1 11 / 3.4 2 / 0.6 1 / 0.3 21/2”DN65 2 / 0.6 12 / 3.7 12 / 3.7 3 / 0.9 2 / 0.6 3”DN80 2 / 0.6 15 / 4.6 13 / 4.0 4 / 1.2 2 / 0.6 CPVC Fittings Allowances for Friction Loss in Fittings Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice. * LPCB Approved up to and including 2” ** Approval pending.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)*** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com Sprinkler Head 90° Elbow (Metal Thread Insert) Socket x NPT Thread • Sizes Available (Nominal) : 3/4” (DN20) through 11/4” (DN32) run, 1/2” (DN15) and 3/4” (DN20) outlet. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Threaded Connections : 1 female threaded NPT outlet. • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricAB 3/4” x 1/2”DN20 x DN15 / 0.56 / 1.62 0.22 / 0.099 V50073SBI-101 1” x 1/2”DN25 x DN15 / 0.50 / 1.75 0.27 / 0.122 V50073SBI-130 1” x 3/4”DN25 x DN20 / 0.59 / 1.88 0.27 / 0.122 V50073SBI-131 11/4” x 1/2”DN32 x DN15 / 0.48 / 1.95 1.86 / 0.844 V50073SBI-166 Sprinkler Head 90° Elbow (Metal Thread Insert) - Socket x NPT Thread Physical Data Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4”DN20 1 / 0.3 3 / 0.9 7 / 2.1 1 / 0.3 1 / 0.3 1”DN25 1 / 0.3 5 / 1.5 7 / 2.1 1 / 0.3 1 / 0.3 11/4”DN32 1 / 0.3 6 / 1.8 8 / 2.4 2 / 0.6 1 / 0.3 11/2”DN40 1 / 0.3 8 / 2.4 9 / 2.7 2 / 0.6 1 / 0.3 2”DN50 1 / 0.3 10 / 3.1 11 / 3.4 2 / 0.6 1 / 0.3 21/2”DN65 2 / 0.6 12 / 3.7 12 / 3.7 3 / 0.9 2 / 0.6 3”DN80 2 / 0.6 15 / 4.6 13 / 4.0 4 / 1.2 2 / 0.6 CPVC Fittings Allowances for Friction Loss in Fittings Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” ** Approval pending. *** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com 45° Elbow Socket x Socket • Sizes Available (Nominal) : 3/4” (DN20) through 3” (DN80) pipe diameters. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricJ 3/4”DN20 / 0.32 0.06 / 0.027 V5006-007 1”DN25 / 0.39 0.12 / 0.054 V5006-010 11/4”DN32 / 0.48 0.17 / 0.0794 V5006-012 11/2”DN40 / 0.47 0.41 / 0.190 V5006-015 2”DN50 / 0.58 0.62 / 0.280 V5006-020 21/2”DN65 / 0.65 0.93 / 0.420 V5006-025 3”DN80 / 0.76 1.39 / 0.630 V5006-030 45° Elbow - Socket x Socket Physical Data J JNominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4”DN20 1 / 0.3 3 / 0.9 7 / 2.1 1 / 0.3 1 / 0.3 1”DN25 1 / 0.3 5 / 1.5 7 / 2.1 1 / 0.3 1 / 0.3 11/4”DN32 1 / 0.3 6 / 1.8 8 / 2.4 2 / 0.6 1 / 0.3 11/2”DN40 1 / 0.3 8 / 2.4 9 / 2.7 2 / 0.6 1 / 0.3 2”DN50 1 / 0.3 10 / 3.1 11 / 3.4 2 / 0.6 1 / 0.3 21/2”DN65 2 / 0.6 12 / 3.7 12 / 3.7 3 / 0.9 2 / 0.6 3”DN80 2 / 0.6 15 / 4.6 13 / 4.0 4 / 1.2 2 / 0.6 CPVC Fittings Allowances for Friction Loss in Fittings Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” ** Approval pending. *** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com Cross & Reducing Cross Socket x Socket x Socket x Socket • Sizes Available (Nominal) : See tables below. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricAB 3/4”DN20 / 0.60 / 0.60 0.13 / 0.059 V5035-007 1”DN25 / 0.74 / 0.74 0.25 / 0.113 V5035-010 11/4”DN32 / 0.90 / 0.90 0.35 / 0.159 V5035-012 11/2”DN40 / 1.23 / 1.23 0.69 / 0.313 V5035-015 2”DN50 / 1.53 / 1.53 1.02 / 0.463 V5035-020 21/2”DN65 / 1.75 / 1.75 1.70 / 0.771 V5035-025 Cross - Socket x Socket x Socket x Socket Physical Data Reducing Cross - Socket x Socket x Socket x Socket Physical Data Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricAB 1” x 1” x 3/4” x 3/4”DN25 x DN25 x DN20 x DN20 / 0.60 / 0.72 0.18 / 0.082 V5035-131 Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4”DN20 1 / 0.3 3 / 0.9 7 / 2.1 1 / 0.3 1 / 0.3 1”DN25 1 / 0.3 5 / 1.5 7 / 2.1 1 / 0.3 1 / 0.3 11/4”DN32 1 / 0.3 6 / 1.8 8 / 2.4 2 / 0.6 1 / 0.3 11/2”DN40 1 / 0.3 8 / 2.4 9 / 2.7 2 / 0.6 1 / 0.3 2”DN50 1 / 0.3 10 / 3.1 11 / 3.4 2 / 0.6 1 / 0.3 21/2”DN65 2 / 0.6 12 / 3.7 12 / 3.7 3 / 0.9 2 / 0.6 3”DN80 2 / 0.6 15 / 4.6 13 / 4.0 4 / 1.2 2 / 0.6 CPVC Fittings Allowances for Friction Loss in Fittings Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” ** Approval pending. *** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com Sprinkler Head Cross - Sidewall (Metal Thread Inserts) Socket x Socket x NPT Thread x NPT Thread • Sizes Available (Nominal) : See table below • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Threaded Connections : 2 female threaded NPT outlets. • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricABCD 1” x 1” x 1/2” x 1/2”DN25 x DN25 x DN15 x DN15 / 1.18 / 1.18 / 0.62 / 0.62 0.46 / 0.209 V50353SBIS-130 Sprinkler Head Cross - Sidewall (Metal Thread Inserts) - Soc x Soc x NPT x NPT Physical Data Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4”DN20 1 / 0.3 3 / 0.9 7 / 2.1 1 / 0.3 1 / 0.3 1”DN25 1 / 0.3 5 / 1.5 7 / 2.1 1 / 0.3 1 / 0.3 11/4”DN32 1 / 0.3 6 / 1.8 8 / 2.4 2 / 0.6 1 / 0.3 11/2”DN40 1 / 0.3 8 / 2.4 9 / 2.7 2 / 0.6 1 / 0.3 2”DN50 1 / 0.3 10 / 3.1 11 / 3.4 2 / 0.6 1 / 0.3 21/2”DN65 2 / 0.6 12 / 3.7 12 / 3.7 3 / 0.9 2 / 0.6 3”DN80 2 / 0.6 15 / 4.6 13 / 4.0 4 / 1.2 2 / 0.6 CPVC Fittings Allowances for Friction Loss in Fittings Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” ** Approval pending. *** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com Coupling Socket x Socket • Sizes Available (Nominal) : 3/4” (DN20) through 3” (DN80) pipe diameters. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricA 3/4”DN20 / 0.10 0.05 / 0.023 V5001-007 1”DN25 / 0.09 0.08 / 0.036 V5001-010 11/4”DN32 / 0.10 0.13 / 0.059 V5001-012 11/2”DN40 / 0.24 0.37 / 0.168 V5001-015 2”DN50 / 0.19 0.52 / 0.236 V5001-020 21/2”DN65 / 0.13 0.68 / 0.308 V5001-025 3”DN80 / 0.16 1.05 / 0.476 V5001-030 Coupling - Socket x Socket Physical Data A Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4”DN20 1 / 0.3 3 / 0.9 7 / 2.1 1 / 0.3 1 / 0.3 1”DN25 1 / 0.3 5 / 1.5 7 / 2.1 1 / 0.3 1 / 0.3 11/4”DN32 1 / 0.3 6 / 1.8 8 / 2.4 2 / 0.6 1 / 0.3 11/2”DN40 1 / 0.3 8 / 2.4 9 / 2.7 2 / 0.6 1 / 0.3 2”DN50 1 / 0.3 10 / 3.1 11 / 3.4 2 / 0.6 1 / 0.3 21/2”DN65 2 / 0.6 12 / 3.7 12 / 3.7 3 / 0.9 2 / 0.6 3”DN80 2 / 0.6 15 / 4.6 13 / 4.0 4 / 1.2 2 / 0.6 CPVC Fittings Allowances for Friction Loss in Fittings Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” ** Approval pending. *** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com Reducer Coupling Socket x Socket • Sizes Available (Nominal) : 1” (DN25) through 21/2” (DN65) inlet, 3/4” (DN20) through 2” outlet. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricA 1” x 3/4”DN25 x DN20 / 0.29 0.07 / 0.032 V5001R-131 11/4” x 1”DN32 x DN25 / 0.35 0.12 / 0.054 V5001R-168 11/2” x 3/4”DN40 x DN20 / 1.02 0.31 / 0.140 V5001R-210 11/2” x 1”DN40 x DN25 / 0.88 0.33 / 0.150 V5001R-211 11/2” x 11/4”DN40 x DN32 / 0.76 0.50 / 0.230 V5001R-212 2” x 1”DN50 x DN25 / 0.97 0.44 / 0.200 V5001R-249 2” x 11/2”DN50 x DN40 / 0.46 0.50 / 0.230 V5001R-251 Reducer Coupling - Socket x Socket Physical Data A Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4”DN20 1 / 0.3 3 / 0.9 7 / 2.1 1 / 0.3 1 / 0.3 1”DN25 1 / 0.3 5 / 1.5 7 / 2.1 1 / 0.3 1 / 0.3 11/4”DN32 1 / 0.3 6 / 1.8 8 / 2.4 2 / 0.6 1 / 0.3 11/2”DN40 1 / 0.3 8 / 2.4 9 / 2.7 2 / 0.6 1 / 0.3 2”DN50 1 / 0.3 10 / 3.1 11 / 3.4 2 / 0.6 1 / 0.3 21/2”DN65 2 / 0.6 12 / 3.7 12 / 3.7 3 / 0.9 2 / 0.6 3”DN80 2 / 0.6 15 / 4.6 13 / 4.0 4 / 1.2 2 / 0.6 CPVC Fittings Allowances for Friction Loss in Fittings Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” ** Approval pending. *** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com Coupling Adapter Socket x Groove • Sizes Available (Nominal) : 11/4” (DN32) through 3” (DN80) pipe diameters. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size K (in./mm) Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricABC 11/4”DN32 1.66 / 42,2 / 0.83 / 1.04 / 2.98 0.17 / 0.077 V5001G-012 11/2”DN40 1.90 / 48,3 / 0.95 / 1.17 / 3.15 0.20 / 0.091 V5001G-015 2”DN50 2.375 / 60,3 / 1.18 / 1.43 / 3.37 0.30 / 0.136 V5001G-020 21/2”DN65 2.875 / 73,0 / 1.43 / 1.74 / 3.66 0.52 / 0.236 V5001G-025 3”DN80 3.50 / 88,9 / 3.50 ----0.72 / 0.327 V5001G-030 Coupling Adapter - Socket x Groove Physical Data C BA Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4”DN20 1 / 0.3 3 / 0.9 7 / 2.1 1 / 0.3 1 / 0.3 1”DN25 1 / 0.3 5 / 1.5 7 / 2.1 1 / 0.3 1 / 0.3 11/4”DN32 1 / 0.3 6 / 1.8 8 / 2.4 2 / 0.6 1 / 0.3 11/2”DN40 1 / 0.3 8 / 2.4 9 / 2.7 2 / 0.6 1 / 0.3 2”DN50 1 / 0.3 10 / 3.1 11 / 3.4 2 / 0.6 1 / 0.3 21/2”DN65 2 / 0.6 12 / 3.7 12 / 3.7 3 / 0.9 2 / 0.6 3”DN80 2 / 0.6 15 / 4.6 13 / 4.0 4 / 1.2 2 / 0.6 CPVC Fittings Allowances for Friction Loss in Fittings Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” ** Approval pending. *** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com Female Adapter (Metal Thread Insert) Socket x NPT Thread • Sizes Available (Nominal) : 3/4” (DN20) through 2” (DN50) pipe diameters. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Threaded Connections : 1 female threaded NPT outlet. Note : 4235-012BS & 4235-015BS female threaded BSP. • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricA 3/4”DN20 / 1.19 0.28 / 0.127 V5003BI-007 1”DN25 / 1.59 0.63 / 0.286 V5003BIBSP-010 11/4”DN32 / 1.97 1.07 / 0.485 V5003BIBSP-012 11/2”DN40 / 1.98 1.33 / 0.603 V5003BIBSP-015 2”DN50 / 1.99 2.00 / 0.907 V5003BIBSP-020 Female Adapter (Metal Thread Insert) - Socket x NPT Thread Physical Data Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4”DN20 1 / 0.3 3 / 0.9 7 / 2.1 1 / 0.3 1 / 0.3 1”DN25 1 / 0.3 5 / 1.5 7 / 2.1 1 / 0.3 1 / 0.3 11/4”DN32 1 / 0.3 6 / 1.8 8 / 2.4 2 / 0.6 1 / 0.3 11/2”DN40 1 / 0.3 8 / 2.4 9 / 2.7 2 / 0.6 1 / 0.3 2”DN50 1 / 0.3 10 / 3.1 11 / 3.4 2 / 0.6 1 / 0.3 21/2”DN65 2 / 0.6 12 / 3.7 12 / 3.7 3 / 0.9 2 / 0.6 3”DN80 2 / 0.6 15 / 4.6 13 / 4.0 4 / 1.2 2 / 0.6 CPVC Fittings Allowances for Friction Loss in Fittings Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice.15-07-2013Datasheet updates the version of 21-05-2013 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” ** Approval pending. *** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com Female Adapter - (Metal Thread Insert) Spigot x NPT Thread • Sizes Available (Nominal) : Female Adapter : 3/4” (DN20) and 1” (DN25) pipe diameters. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) at 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) • Threaded Connections : 1 female threaded NPT outlet. • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricA 3/4”DN20 / 2.00 0.28 / 0.127 V50032BI-007 1”DN25 / 2.72 0.61 / 0.277 V50032BI-010 Female Adapter - (Metal Thread Insert) - Spigot x NPT Thread Physical Data Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4”DN20 1 / 0.3 3 / 0.9 7 / 2.1 1 / 0.3 1 / 0.3 1”DN25 1 / 0.3 5 / 1.5 7 / 2.1 1 / 0.3 1 / 0.3 11/4”DN32 1 / 0.3 6 / 1.8 8 / 2.4 2 / 0.6 1 / 0.3 11/2”DN40 1 / 0.3 8 / 2.4 9 / 2.7 2 / 0.6 1 / 0.3 2”DN50 1 / 0.3 10 / 3.1 11 / 3.4 2 / 0.6 1 / 0.3 21/2”DN65 2 / 0.6 12 / 3.7 12 / 3.7 3 / 0.9 2 / 0.6 3”DN80 2 / 0.6 15 / 4.6 13 / 4.0 4 / 1.2 2 / 0.6 CPVC Fittings Allowances for Friction Loss in Fittings Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” ** Approval pending. *** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com Sprinkler Head Adapter - Female (Metal Thread Insert) Socket x NPT Thread • Sizes Available (Nominal) : 3/4” (DN20) pipe run x 1/2” (DN15) outlet, 1” (DN25) pipe run x 1/2” (DN15) outlet and 1” (DN25) pipe run x 3/4” (DN20) outlet. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Threaded Connections : 1 female threaded NPT outlet. • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricA 3/4” x 1/2”DN20 x DN15 / 0.75 0.18 / 0.082 V5003SBI-101 1” x 1/2”DN25 x DN15 / 0.76 0.21 / 0.095 V5003SBI-130 1” x 3/4”DN25 x DN20 / 0.95 0.18 / 0.082 V5003SBI-131 Sprinkler Head Adapter - Female (Metal Thread Insert) - Socket x NPT Thread Physical Data Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4”DN20 1 / 0.3 3 / 0.9 7 / 2.1 1 / 0.3 1 / 0.3 1”DN25 1 / 0.3 5 / 1.5 7 / 2.1 1 / 0.3 1 / 0.3 11/4”DN32 1 / 0.3 6 / 1.8 8 / 2.4 2 / 0.6 1 / 0.3 11/2”DN40 1 / 0.3 8 / 2.4 9 / 2.7 2 / 0.6 1 / 0.3 2”DN50 1 / 0.3 10 / 3.1 11 / 3.4 2 / 0.6 1 / 0.3 21/2”DN65 2 / 0.6 12 / 3.7 12 / 3.7 3 / 0.9 2 / 0.6 3”DN80 2 / 0.6 15 / 4.6 13 / 4.0 4 / 1.2 2 / 0.6 CPVC Fittings Allowances for Friction Loss in Fittings Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” ** Approval pending. *** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com Sprinkler Head Adapter - (Metal Thread Insert) Spigot x NPT Thread • Sizes Available (Nominal) : 3/4” (DN20) and 1” (DN25) pipe run, 1/2” (DN15) outlet. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Threaded Connections : 1 female threaded NPT outlet. • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricA 3/4” x 1/2”DN20 x DN15 / 1.50 0.19 / 0.086 V50032SBI-101 1” x 1/2”DN25 x DN15 / 1.85 0.18 / 0.082 V50032SBI-130 Sprinkler Head Adapter - (Metal Thread Insert) - Spigot x NPT Thread Physical Data Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4”DN20 1 / 0.3 3 / 0.9 7 / 2.1 1 / 0.3 1 / 0.3 1”DN25 1 / 0.3 5 / 1.5 7 / 2.1 1 / 0.3 1 / 0.3 11/4”DN32 1 / 0.3 6 / 1.8 8 / 2.4 2 / 0.6 1 / 0.3 11/2”DN40 1 / 0.3 8 / 2.4 9 / 2.7 2 / 0.6 1 / 0.3 2”DN50 1 / 0.3 10 / 3.1 11 / 3.4 2 / 0.6 1 / 0.3 21/2”DN65 2 / 0.6 12 / 3.7 12 / 3.7 3 / 0.9 2 / 0.6 3”DN80 2 / 0.6 15 / 4.6 13 / 4.0 4 / 1.2 2 / 0.6 CPVC Fittings Allowances for Friction Loss in Fittings Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” ** Approval pending. *** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com Reducer Bushing Spigot x Socket • Sizes Available (Nominal) : 1” (DN25) through 3” (DN80) inlet, 3/4” (DN20) through 21/2” (DN65) outlet. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricLN 1” x 3/4”DN25 x DN20 / 1.28 / 0.27 0.05 / 0.023 V5018-131 11/4” x 3/4”DN32 x DN20 / 1.41 / 0.27 0.05 / 0.023 V5018-167 11/4” x 1” DN32 x DN25 / 1.41 / 0.40 0.06 / 0.027 V5018-168 11/2” x 3/4”DN40 x DN20 / 1.53 / 0.27 0.08 / 0.036 V5018-210 11/2” x 1” DN40 x DN25 / 1.53 / 0.40 0.09 / 0.041 V5018-211 11/2” x 11/4”DN40 x DN32 / 1.53 / 0.40 0.10 / 0.045 V5018-212 2” x 3/4”DN50 x DN20 / 1.66 / 0.65 0.20 / 0.091 V5018-248 2” x 1”DN50 x DN25 / 1.66 / 0.27 0.22 / 0.100 V5018-249 2” x 11/4”DN50 x DN32 / 1.66 / 0.40 0.24 / 0.109 V5018-250 2” x 11/2”DN50 x DN40 / 1.66 / 0.52 0.25 / 0.113 V5018-251 21/2” x 11/4”DN65 x DN32 / 1.94 / 0.55 0.27 / 0.122 V5018-290 21/2” x 11/2”DN65 x DN40 / 1.94 / 0.68 0.31 / 0.141 V5018-291 21/2” x 2”DN65 x DN50 / 1.94 / 0.80 0.31 / 0.141 V5018-292 3” x 2”DN80 x DN50 / 2.42 / 0.64 0.48 / 0.218 V5018-338 3” x 21/2”DN80 x DN65 / 2.42 / 0.91 0.64 / 0.290 V5018-339 Refer to the “CPVC Equal Tee” datapage or manufacturer’s installation instructions for friction loss information. Reducer Bushing - Spigot x Socket Physical Data L N Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” ** Approval pending. *** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com Cap Socket • Sizes Available (Nominal) : 3/4” (DN20) through 3” (DN80) pipe diameters. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricA 3/4”DN20 / 0.31 0.08 / 0.036 V5017-007 1”DN25 / 0.38 0.14 / 0.064 V5017-010 11/4” DN32 / 0.40 0.20 / 0.091 V5017-012 11/2”DN40 / 0.41 0.26 / 0.118 V5017-015 2” DN50 / 0.42 0.38 / 0.172 V5017-020 21/2”DN65 / 0.57 0.57 / 0.259 V5017-025 3” DN80 / 1.26 0.87 / 0.395 V5017-030 Cap - Socket Physical Data A A Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” ** Approval pending. *** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com Test Plug NPT Thread • Sizes Available (Nominal) : 1/2” (DN15) pipe diameter. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : For pressure testing only • Threaded Connections : Threaded NPT • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. This product is FM Approved for pressure testing only. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricA 1/2”DN15 / 1.06 0.03 / 0.014 V450-005 Test Plug - Thread Physical Data A Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” ** Approval pending. *** Worldwide Fire Protection CPVC Pipe & Fittingswww.vikinggroupinc.com Union Socket x Socket • Sizes Available (Nominal) : 3/4” (DN20) through 2” (DN50) pipe diameters. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4” (DN20) through 11/4” (DN32) and in Schedule 80 for sizes 11/2” (DN40) through 3” (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. Technical Features Nominal Pipe Size Dimensions (mm / inch)Approx. Weight (lbs. / kgs.)Part NumberinchmetricAL 3/4”DN20 / 2.46 / 0.43 0.27 / 0.122 V5033E-007 1”DN25 / 2.70 / 0.43 0.40 / 0.181 V5033E-010 11/4” DN32 / 3.31 / 0.79 0.87 / 0.395 V5033E-012 11/2”DN40 / 3.58 / 0.80 0.93 / 0.422 V5033E-015 2” DN50 / 3.82 / 0.80 1.83 / 0.830 V5033E-020 21/2”DN65 / 4.74 / 0.93 3.47 / 1.574 V5033E-025 3”DN80 / 5.05 / 1.42 3.95 / 1.792 V5033E-030 Union - Socket x Socket Physical Data L A Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4”DN20 1 / 0.3 3 / 0.9 7 / 2.1 1 / 0.3 1 / 0.3 1”DN25 1 / 0.3 5 / 1.5 7 / 2.1 1 / 0.3 1 / 0.3 11/4”DN32 1 / 0.3 6 / 1.8 8 / 2.4 2 / 0.6 1 / 0.3 11/2”DN40 1 / 0.3 8 / 2.4 9 / 2.7 2 / 0.6 1 / 0.3 2”DN50 1 / 0.3 10 / 3.1 11 / 3.4 2 / 0.6 1 / 0.3 21/2”DN65 2 / 0.6 12 / 3.7 12 / 3.7 3 / 0.9 2 / 0.6 3”DN80 2 / 0.6 15 / 4.6 13 / 4.0 4 / 1.2 2 / 0.6 CPVC Fittings Allowances for Friction Loss in Fittings Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer’s datasheet. Specifications subject to change without notice.21-05-2013Datasheet updates the version of 2008-08-12 (Changed WRAS Logo and added note regarding fittings)* LPCB Approved up to and including 2” ** Approval pending. *** FIRE SPRINKLERS – FIRE ALARMS – FIRE EXTINGUISHERS – EMERGENCY LIGHTING – SAFETY & FIRST AID SUPPLIES Page 6 of 7 6438 Arville St. Las Vegas, NV 89118 (702) 966-8021 Tel (702) 987-1174 Fax www.onguardfp.com License #: NV-61307 CA-950378 Bid Limit $4.5 M 4. Valves Spears® Technical Information 11-Mar-16 03:20:38 PM FlameGuard®Swing Check ValvesPart No:S1520-10CO 1 CPVC SWING CHECK VALVE SOC EPDMDesc: Part Code:004MSRP:33.81 0.186 Weight(gm):186Weight(lbs):0.41 Weight(kg): ORANGE Material:CPVCSize:1 Color: Connection Socket x Socket Type Swing Check Gasket EPDM Note UL Listed A 1-11/16=B 2-5/16=C 4-9/16=D 2-5/8= Injection Molded Dimension References: G =(LAYING LENGTH) intersection of center lines to bottom of socket/thread; 90° elbows, tees, crosses; ± 1/32 inch. H =Intersection of center lines to face of fitting; 90° elbows tees, crosses; ± 1/32 inch. J =Intersection of center lines to bottom of socket/thread; 45° elbows; ± 1/32 inch L =Overall length of fittings; ± 1/16 inch. M =Outside diameter of socket/thread hub; ± 1/16 inch. N =Socket bottom to socket bottom; couplings; ± 1/16 inch. W =Height of cap; ± 1/16 inch Typical Molded Dimension References The information printed here is based on current information & product design at the time of publication and is subject to change without notification. Spears® ongoing commitment to product improvement may result in some variation. No representation, guarantees or warranties of any kind are as to its accuracy, suitability for particular application or results to be obtained thereform. For verification of technical data or additional information, please contact Spears® Technical Service Department :: WEST COAST : (818) 364-1611 - EAST COAST : (717) 938-9006 FIRE SPRINKLERS – FIRE ALARMS – FIRE EXTINGUISHERS – EMERGENCY LIGHTING – SAFETY & FIRST AID SUPPLIES Page 7 of 7 6438 Arville St. Las Vegas, NV 89118 (702) 966-8021 Tel (702) 987-1174 Fax www.onguardfp.com License #: NV-61307 CA-950378 Bid Limit $4.5 M 5. Accessories & Caulking Hanger & surge restraint for horizontal CPVC piping when installed on the side of supporting structure. •For mounting CPVC pipe to wood •Flared edges help protect CPVC •Galvanized steel construction •Supplied with #10 hex head cap screws •Complies with the static load requirements of NFPA® 13 •Suitable for fire protection installations •Size Range: 3/4" through 1" Designed to mount CPVC pipe horizontally or vertically to wood or composite wood joists with a minumum 3/8” thickness. Offset edge eliminates abrasion. Installation: Per NFPA 13, 13R and 13D. Install into wood or steel. Slides onto CPVC pipe. 3/4" pipe size | Item #2530181-3/4 1" pipe size | Item #2530181-1 CPVC PIPE HANGER SUPPORT DOUBLE OFFSET DESIGN System No. Location Submitted By Date Spec Section Paragraph Approved Date ARGCO.com Updated 4/16/2019 © ARGCO CPVC STRAP TWO HOLE 90° WRAP AROUND Provides support for CPVC or Polybutalene fire sprinkler piping in fire sprinkler systems installed per NFPA 13, 13R and 13D. •Fastened with a Hardened Hex Head Screw, #10x1-1/2", supplied with the strap. •Pre-galvanized finish. Galvanized carbon steel construction,supplied with hex slotted screws CPVC PIPE SIZE 3/4” 1” 1-1/4” 1-1/2” 2” ITEM # 2530160-3/4 2530160-1 2530160-1-1/4 2530160-1-1/2 2530160-2 INSTALLATION: 1. Snap CPVC pipe hanger into hanger. Dimples hold pipe in place. 2. Mount hanger onto wood beam with screws provided. 3. Anchor tightly to surface, be sure that pipe can slide freely through hanger. System No. Location Submitted By Date Spec Section Paragraph Approved Date ARGCO.com Updated 2/19/2019 © ARGCO A 1" 1-7/16" 1-5/8" 1-3/4" 1-11/16" B 2-7/16" 2-11/16" 3-1/16" 3-5/16" 3-3/4" MAX HANGER SPACING 5-1/2" 6" 6-1/2" 7" 8" TOLCO® 12722 12746 12753 12760 12777 ERICO® 1070075 1070100 1070125 1070150 1070200 CROSS REFCPVC STRAP TWO HOLE 90° WRAP AROUND CUS B A support Installation and configuration shall conform to the requirements of the NFPA 13, instructions and applicable local codes. Install with hanger tabs upward only. Do not install on the bottom of a beam or under horizontal surface. Hanger for CPVC pipe in the horizontal position on the side of structural wood beams and Steel 20 Ga. (min) with hanger tab in the upward position only. It can also be used AS A GUIDE ONLY to limit movement of vertical CPVC pipe with the tab in the horizontal position. Installation and configuration shall conform to the requirements of the NFPA 13, instructions and applicable local codes. data sheet The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM CPVC Two-Hole 90° Side Mount Strap •Top or bottom beam installation •Galvanized steel, supplied with 1” hex screws C US TOLCO® 012845 012869 012876 012883 012890 ERICO® 597827 597828 597829 597831 597832 Size 3/4” 1” 1-1/4” IPS 1-1/2” IPS 2” IPS Item # 25-30-175-3/4 25-30-175-1 25-30-175-1-1/4 25-30-175-1-1/2 25-30-175-2 CROSS REFERENCE 1. Snap CPVC pipe hanger into hanger. Dimples hold pipe in place. 2. Mount hanger onto wood beam with screws provided. 3. May also be used on the underside of beam. 4. Do anchor tightly to surface, be sure that pipe can slide freely through hanger. wood beam May be used as a guide in the upward position. Not designed to restrain upward movement of pipe. C US File VIXH.EX6587 STAND-OFF TWO HOLE STRAP NO BLOCK FOR CPVC NPS 3/4” 1” 1-1/4” 1-1/2” 2” • For mounting CPVC pipe to wood • Flared edges help protect CPVC • Galvanized steel construction • Supplied with #10 x 1” hex head cap screws • Complies with the static load requirements of NFPA® 13 • Suitable for fire protection installations • Eliminates spacers or backup blocks • Easy installation CUS A 2.69” 2.94” 3.31” 3.56” 4.06” B 3.25” 3.25” 3.25” 4.5” 5” MAX. HANGER SPACING 5.5 ft / 1.68 m 6 ft / 1.83 m 6.5 ft / 1.98 m 7 ft / 2.13 m 8 ft / 2.44 m 1” .25” A B Designed to mount CPVC pipe horizontally or vertically to structural wood members with fasteners provided. Can only be used as a guide on top of beam or on vertical piping. May be installed to wood using supplied fastener or into (minimum 18 gauge) steel using two 1/4" x 1" TEK type screws. Provides vertical/lateral restraint and prevents upward movement of the pipe that supplies pendant fire sprinkler below ceiling. All sizes can be used as a restrainer in the bottom position. The 3/4” size only can be used as a restrainer in the top position. Installation: Per NFPA 13, 13R and 13D. (see page two) top mount bottom mount side mount Fasteners: Wood - 3/4” to 3” CPVC Pipe - wood screw - no pre-drill Steel - 3/4” to 3” CPVC Pipe - 1/4” TEK screw For use as a restrainer in all sizes when attached to the bottom of structural wood members. For use as a restrainer in the 3/4 inch size when attached to the top of structural wood members ARGCO MODEL # 2530180 System No. Location Submitted By Date Spec Section Paragraph Approved Date ARGCO.com Updated 3/9/2020 © ARGCO Designed to mount CPVC pipe to wood or composite wood joists with a minumum 3/8” thickness. 1. Snap strap over CPVC pipe. 2. Squeeze strap back around pipe. Allowing pipe to slide back and forth. 3. Fasten the strap to the wood surface using the two hex head screws provided. NOTE: All sizes can be used as a restrainer in the bottom position. The 3/4” size only can be used as a restrainer in the top position. INSTALLATION INSTRUCTIONS System No. Location Submitted By Date Spec Section Paragraph Approved Date ARGCO.com Updated 3/9/2020 © ARGCO STAND-OFF TWO HOLE STRAP NO BLOCK FOR CPVC data sheet The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM CPVC TWO HOLE STRAP Galvanized steel construction Designed for support or restraint fo piping in either a vertical or horizon- tal position. It can be used on top or bottom of a beam. The edges are flared to provent any damage to the CPVC pipe. It is easily attached using 2 hex head self-threading screws (supplied) Galvanized steel, supplied with hex slotted screws size 3/4” 1” 1-1/4” 1-1/2” 2” part # 25-30-283 25-30-284 25-30-285 25-30-286 25-30-287 1. SNAP CPVC PIPE INTO HANGER. 2. MOUNT HANGER TO UNDERSIDE OF BEAM WITH SCREWS PROVIDED. 3. MAY ALSO BE USED ON TOP SIDE OF BEAM. HEX HEAD SCREWS C US File VIXH.EX6587 Residential Fire Protection dba License #: NV-61307 CA-950378 6438 Arville Street Las Vegas, NV 89118 (702) 966-8021 Tel (702) 987-1174 Fax www.onguardfp.com May 5, 2022, To whom it may concern, On Guard Fire Protection would like the extension of permit number FSS2021-0226 which just expired. This job site and fire sprinkler permit has been delayed due to Covid-19. Thank you, Vanesa Hernandez On Guard Fire Protection 11800 Sterling Avenue Suite L Riverside, CA 92503 702-966-8021 OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org September 28, 2021 On Guard Fire Protection 1180 Sterling Ave #K Riverside, CA 92503 Re: Residential Fire Sprinkler Plan Review – WOODEN RESIDENCE FSS2021-0226 / 53705 AVENIDA ALVARADO, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 53705 AVENIDA ALVARADO PERMIT#: FSS2021-0226 DATE ISSUED: 9/28/2021 DESCRIPTION: WOODEN RESIDENCE SPK CONTRACTOR: ON GUARD FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.