FSS2021-0234ADDITIONAL SITES
CHRONOLOGY
CONTACTS
NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL
APPLICANT jose martinez 9630 Jurupa R.D Riverside CA 92509 (951)314-4338 josem.acerfire@gmail.c
om
CONTRACTOR ACER FIRE PROTECTION 4661 Mane Street montclair CA 91763 (951)314-4338 josem.acerfire@gmail.c
om
OWNER WASHINGTON ADAM PARTNERSHIP 46753 ADAMS STREET LA QUINTA CA 92253 (951)314-4338
CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES
E-MAIL AARON HICKSON 9/21/2021 9/21/2021 SENT BL APPLICATION TO APPLICANT TO ADD CONTRACTOR
ACCOUNT
CONDITIONS
Description: modification of existing system
Type: FIRE SPRINKLER (WEB)Subtype:
COMMERCIAL/INDUSTRIAL
Status: FINALED Applied: 9/20/2021 EPRS
Parcel No: 643220001 Site Address: 78670 HIGHWAY 111 LA QUINTA,CA 92253 Approved: 10/4/2021 KHET
Subdivision: PM 25865 Block: Lot: 2 Issued: 10/25/2021 JOD
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 11/9/2021 KHET
Valuation: $1,000.00 Occupancy Type: Construction Type: Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: RELOCATE 3 PENDENT HEADS
FINANCIAL INFORMATION
Printed: Friday, March 03, 2023 8:45:26 AM 1 of 3
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2021-0234
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED
DATE
COMPLETED
DATE
RESULT REMARKS NOTES
OVERHEAD ROUGH
PIPING KHET 10/28/2021 10/28/2021 APPROVED SEE NOTES QR heads added need to be changed to SSP
as existing style in the occupancy.
FIRE FINAL**KHET 11/9/2021 11/9/2021 APPROVED All items addressed.
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED
DATE STATUS REMARKS NOTES
1ST FIRE - ETRAKIT
(2 WK)
KOHL
HETRICK 9/20/2021 10/4/2021 10/4/2021 APPROVED SEE ATTACHMENTS
PARENT PROJECTS
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
FIRE SPRINKLER
SYSTEMS
COMMERCIAL/INDUSTR
IAL
101-0000-42421 0 $161.00 $161.00 10/25/21 WEB9703 633197281
87 CREDIT jose martinez EPRS
FIRE SPRINKLER
SYSTEMS
COMMERCIAL/INDUSTR
IAL PC
101-0000-42420 0 $80.50 $80.50 10/25/21 WEB9703 633197281
87 CREDIT jose martinez EPRS
Total Paid for FIRE FEES: $241.50 $241.50
RECORDS
MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 10/25/21 WEB9703 633197281
87 CREDIT jose martinez EPRS
Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00
TECHNOLOGY
ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 10/25/21 WEB9703 633197281
87 CREDIT jose martinez EPRS
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
TOTALS:$256.50 $256.50
Printed: Friday, March 03, 2023 8:45:26 AM 2 of 3
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2021-0234
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 9/20/2021 Etrakit Public
Registration
1ST SUBMITTAL FIRE
SPRINKLER PLAN
NAILS STUDIO FIRE
SPRINKLER PLAN LA
QUINTA CA.pdf
1
DOC 9/20/2021 Etrakit Public
Registration
1ST SUBMITTAL FIRE
SPRINKLER CUTSHEET 031414.pdf 1
DOC 10/4/2021 KOHL HETRICK FSS2021-0234 -
APPROVED PLANS.pdf
FSS2021-0234 -
APPROVED PLANS.pdf 1
DOC 10/4/2021 KOHL HETRICK FSS2021-0234 - COA
AND JOB CARD.pdf
FSS2021-0234 - COA
AND JOB CARD.pdf 1
BOND INFORMATION
1ST PERMIT TECH –
ETRAKIT (1 DAY)
AARON
HICKSON 9/20/2021 9/21/2021 9/21/2021 COMPLETE NEED TO ADD CONTRACTOR ACCOUNT WHEN BL
APPLICATION IS CREATED. 1047478
Printed: Friday, March 03, 2023 8:45:26 AM 3 of 3
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2021-0234
FSS2021-0234
MICROMATIC® STANDARD
RESPONSE PENDENT
SPRINKLER VK102 (K5.6)
TECHNICAL DATA
Page 1 of 7
Form No. F_031414 20.10.20 Rev 20.1
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
1. DESCRIPTION
The Viking Micromatic® Standard Response Pendent VK102 Sprinkler is a small, thermosensitive,
glass-bulb spray sprinkler available in several different finishes and temperature ratings to meet design
requirements. The special Polyester, and Electroless Nickel PTFE (ENT) coatings can be used in
decorative applications where colors are desired. In addition, these coatings have been investigated
for installation in corrosive environments and are listed/approved as indicated in the Approval
Charts.
Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and
pip cap assembly removed) on deluge systems. Refer to Ordering Instructions.
2. LISTINGS AND APPROVALS
cULus Listed: Category VNIV
FM Approved: Classes 2001, 2002, 2015, 2017, 2043
VdS Approved: Certificate G414006 & G414004
LPCB Approved
CE: Standard EN 12259-1, DOP_Sprinklers_LPCB_5-2-19 & DOP_VK102WAX_2-12-19
MED Certified: Standard EN 12259-1, EC-certificate 0832-MED-1003
China Approval: Approved according to China GB standard.
NOTE: Other International approval certificates are available upon request.
Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed.
3. TECHNICAL DATA
Specifications:
Minimum Operating Pressure: 7 psi (0.5 bar)*
Maximum Working Pressure: 175 psi (12 bar) wwp
Factory tested hydrostatically to 500 psi (34.5 bar)
Thread size: 1/2” NPT, 15 mm BSPT
Nominal K-factor: 5.6 U.S. (80.6 metric**)
Glass-bulb fluid temperature rated to -65 °F (-55 °C)
Overall Length: 2-1/4” (57 mm)
* cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar).
** Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
Material Standards:
Frame Casting: Brass UNS-C84400 or QM Brass
Deflector: Phosphor Bronze UNS-C51000 (Not for FM Approval) or Copper UNS-C19500
Bulb: Glass, nominal 5 mm diameter
Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape
Screw: Brass UNS-C36000
Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400
For Polyester Coated Sprinklers: Belleville Spring-Exposed
For ENT coated Sprinklers: Belleville Spring - Exposed, Screw and Pipcap - ENT plated.
Ordering Information: Refer to Table 1
4. INSTALLATION
Refer to appropriate NFPA Installation Standards.
5. OPERATION
During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and
sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern
to extinguish or control the fire.
6. INSPECTIONS, TESTS AND MAINTENANCE
Refer to NFPA 25 for Inspection, Testing and Maintenance requirements.
Replaces Form No. F_031414 Rev 19.2
(Revised CE approval)
MICROMATIC® STANDARD
RESPONSE PENDENT
SPRINKLER VK102 (K5.6)
TECHNICAL DATA
Page 2 of 7
Form No. F_031414 20.10.20 Rev 20.1
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
7. AVAILABILITY
The Viking Micromatic® Standard Response Upright Sprinkler VK100 is available through a network of domestic and international
distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation.
8. GUARANTEE
For details of warranty, refer to Viking’s current list price schedule or contact Viking directly.
TABLE 1: ORDERING INFORMATION
Instructions: Using the sprinkler base part number,
(1) add the suffix for the desired Finish
(2) add the suffix for the desired Temperature Rating.
Sprinkler
Base Part
No.
Size 1: Finishes 2: Temperature Ratings
NPT
Inch
BSPT
mm Description Suffix1 Nominal
Rating
Bulb
Color
Hazard
Classification
Max. Ambient Ceiling
Temperature2 Suffix
12987 1/2 --Brass A 135 °F (57 °C)Orange Ordinary 100 °F (38 °C)A
12989 --15 Chrome F 155 °F (68 °C)Red Ordinary 100 °F (38 °C)B
20229 --15 White Polyester 3,5 M-/W 175 °F (79 °C)Yellow Intermediate 150 °F (65 °C)D
Black Polyester 3,5 M-/B 200 °F (93 °C)Green Intermediate 150 °F (65 °C)E
Wax C 212 °F (100 °C)Green Intermediate 150 °F (65 °C)M
Wax over Polyester V-/W 286 °F (141 °C)Blue High 225 °F (107 °C)G
ENT 3,4,5 JN 360 °F (182 °C)Mauve Extra High 300 °F (149 °C)H
500 °F (260 °C)Black Ultra High6 465 °F (240 °C)L
Example: 12987MB/W = VK102 with White Polyester Finish and 155 °F (68 °C) Nominal temperature rating. This sprinkler is to be installed into an
area with a maximum ambient temperature of 100 °F (38 °C) meaning if the area will experience temperatures above the maximum ambient rating,
you shall use a higher temperature-rated sprinkler.
Corrosion Resistant Coatings5
• White Polyester and Black Polyester in all temperature ratings.
• ENT in all temperature ratings except 135 °F (57 °C).
• Wax-Coated Brass and Wax over Polyester7 for sprinklers with the following temperature ratings:
155 °F (68 °C) Lt. Brown Wax | 175 °F (79 °C) Brown Wax | 200 °F (93 °C) Brown Wax | 286 °F (141 °C) Dk. Brown Wax7
Accessories
Sprinkler Wrenches (see Figure 1):
A. Standard Wrench: Part No. 21475M/B
B. Standard Wrench for Wax Coated Sprinklers: Part No. 10896W/B
C. Socket Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B (A 1/2” ratchet is required, not available from Viking)
D. Socket Wrench for Wax Coated Sprinklers: Part No. 13577W/B (A 1/2” ratchet is required, not available from Viking)
E. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool9: Part No. 15915
Sprinkler Cabinet:
A. Up to 6 sprinklers: Part number 01724A (available since 1971).
B. 6-12 Sprinklers: Part number 01725A (available since 1971).
Footnotes
1. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above.
2. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards.
3. UL Listed as corrosion resistant.
4. FM Approved corrosion resistant.
5. The corrosion resistant and corrosion proofing coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart(s). These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated.
6. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), response time may be severely retarded
7. Wax melting point is 170 °F (76 °C) for 286 °F (141 °C) temperature rated sprinklers. For more inforamation regarding wax coatings, refer to Bulletin Form No. F_010201.
8. Allows use from the floor by attaching a length of 1” diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808.
MICROMATIC® STANDARD
RESPONSE PENDENT
SPRINKLER VK102 (K5.6)
TECHNICAL DATA
Page 3 of 7
Form No. F_031414 20.10.20 Rev 20.1
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
Figure 1: Sprinkler Wrenches
Figure 2: Sprinkler Dimensions
A C D
B
2-1/4ʺ
(57 mm)
Nominal Pipe Engagement
7/16ʺ
(11 mm)
MICROMATIC® STANDARD
RESPONSE PENDENT
SPRINKLER VK102 (K5.6)
TECHNICAL DATA
Page 4 of 7
Form No. F_031414 20.10.20 Rev 20.1
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
DESIGN CRITERIA - UL
(Also refer to Approval Chart 1.)
cULus Listing Requirements:
The Viking Micromatic0® Standard Response Pendent Sprinkler VK102 is cULus Listed as indicated in Approval Chart 1 for installation in accordance
with the latest edition of NFPA 13 for standard spray sprinklers.
• Designed for use in Light, Ordinary, and Extra Hazard occupancies.
• The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed.
IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable.
Approval Chart 1 (UL)
Micromatic® Standard Response Pendent Sprinkler VK102
Maximum 175 PSI (12 bar) WWP
Sprinkler
Base Part
Number1
SIN
Thread Size Nominal
K-factor Overall Length Listings and Approvals3
(Refer also to UL Design Criteria.)
NPT BSPT U.S.metric2 Inches mm cULus4 VdS LPCB CE8 MED 9 China Approval
12987 VK102 1/2”15 mm 5.6 80.6 2-1/4”57 A1, B3, B1Y, C4, D2, E5, G5Z A1 A1, B3, B1Y F1, G1Y, B412 F2X --
12989 VK102 --15 mm 5.6 80.6 2-1/4”57 A1, B3, B1Y, C4, D2, E5, G5Z A1 A1, B3, B1Y F1, G1Y, B412 F2X --
2022910 VK102 --15 mm 5.6 80.6 2-1/4”57 E6 --------E6
NOTICE - Product Below - No longer offered.
10139 VK102 1/2”15 mm 5.6 80.6 2-1/4”57 A1, B3, B1Y, C4, D2, E5, G5Z ----------
10173 VK102 --15 mm 5.6 80.6 2-1/4”57 A1, B3, B1Y, C4, D2, E5, G5Z A1 A1, B3, B1Y --F2X --
18020 VK102 1/2”15 mm 5.6 80.6 2-1/4”57 A1, B3, B1Y, C4, D2, E5, G5Z A1 A1, B3, B1Y F1, G1X F2X --
Approved Temperature Rating Codes
A = 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C), and 360 °F (182 °C)B = 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C)C = 286 °F (141 °C)D = 500 °F (260 °C)7
E = 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C), 360 °F (182 °C), and 500 °F (260 °C)7
F = 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C), and 360 °F (182 °C)G = 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C)
Approved Finish Codes
1 = Brass, Chrome, White Polyester5,6 and Black Polyester5,6
2 = Brass and Chrome3 = Wax-Coated Brass and Wax Over Polyester5
4 = High Temperature 200 °F (93 °C) Wax Coating (corrosion resistant); maximum ambient temperature allowed at ceiling = 150 °F (65 °C)5 = ENT5
6 = Chrome
Approved Escutcheon Codes
X = Recessed with the Viking Model E-1, E-2, or E-3 Recessed EscutcheonY = Standard surface-mounted escutcheon or recessed with the Viking Model E-1, E-2, or E-3 Recessed EscutcheonZ = Standard surface-mounted escutcheon or recessed with the Viking Model E-1 Recessed Escutcheon
Footnotes
1. Base part number is shown. For complete part number, refer to Viking’s current price schedule.
2. Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
3. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals.
4. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada.
5. cULus Listed as corrosion resistant.
6. Other colors are available on request with the same Listings and Approvals as the standard colors.
7. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded.
8. CE: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-0021.
9. MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008.
10. Approved according to China GB standard.
11. CE: Standard EC 12259-1, Declaration of Performance DOP_Sprinklers_LPCB_5-2-19 & DOP_VK102WAX_2-12-19
MICROMATIC® STANDARD
RESPONSE PENDENT
SPRINKLER VK102 (K5.6)
TECHNICAL DATA
Page 5 of 7
Form No. F_031414 20.10.20 Rev 20.1
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
DESIGN CRITERIA - FM
(Also refer to Approval Chart 2.)
FM Approval Requirements:
The Viking Micromatic® Standard Response Pendent Sprinkler VK102 is is FM Approved as standard response Non-Storage pendent sprinkler as
indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data
Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply
requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling.
NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria.
IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza-
tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable.
Approval Chart 2 (FM)
Micromatic® Standard Response Pendent Sprinkler VK102
Maximum 175 PSI (12 bar) WWP
Sprinkler Base
Part Number1 SIN Thread Size Nominal K-Factor Overall Length FM Approvals3
(Refer also to Design Criteria below.)NPT BSPT U.S.metric2 Inches mm
12987 VK102 1/2”15 mm 5.6 80.6 2-1/4”57 A1, B2, C3, D1, E4, G1Y, G4Z
12989 VK102 --15 mm 5.6 80.6 2-1/4”57 A1, B2, C3, D1, E4, G1Y, G4Z
202297 VK102 --15 mm 5.6 80.6 2-1/4”57 E5
NOTICE - Product Below - Limited Availability (Contact Local Viking Office)
10139 VK102 1/2”15 mm 5.6 80.6 2-1/4”57 A1, B2, C3, D1, E4, G1Y, G4Z
10173 VK102 --15 mm 5.6 80.6 2-1/4”57 A1, B2, C3, D1, E4, G1Y, G4Z
18020 VK102 1/2”15 mm 5.6 80.6 2-1/4”57 A1, B2, C3, D1, G1Y
Approved Temperature Rating Codes
A = 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 212 °F (100 °C), 286 °F (141 °C), and 360 °F (182 °C)
B = 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 212 °F (100 °C)
C = 286 °F (141 °C)
D = 500 °F (260 °C)5
E = 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C), 360 °F (182 °C), and 500 °F (260 °C)5
F = 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C)
G = 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C)
Approved Finish Codes
1 = Brass, Chrome, White Polyester5,6 and Black Polyester5,6
2 = Wax-Coated Brass (corrosion resistant)
3 = High Temperature 200 °F (93 °C) Wax Coating (corrosion resistant); maximum ambient temperature allowed at the ceiling = 150 °F (65 °C)
4 = ENT6
5 = Chrome
Approved Escutcheon Codes
Y = Standard surface-mounted escutcheon or recessed with the Viking Model E-1, E-2, or E-3 Recessed Escutcheon
Z = Standard surface-mounted escutcheon or recessed with the Viking Model E-1 Recessed Escutcheon
Footnotes
1. Base part number is shown. For complete part number, refer to Viking’s current price schedule.
2. Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
3. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals.
4. Other colors are available on request with the same Approvals as the standard colors.
5. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded.
6. FM approved as corrosion resistant.
7. Approved according to China GB standard.
MICROMATIC® STANDARD
RESPONSE PENDENT
SPRINKLER VK102 (K5.6)
TECHNICAL DATA
Page 6 of 7
Form No. F_031414 20.10.20 Rev 20.1
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
Step 1: Carefully slide the
wrench sideways around
the protective cap, ensuring
engagement with the wrench
flats.
Step 1: Carefully slide the
wrench sideways around the
protective cap (not shown),
ensuring engagement with
the wrench flats.
Step 2: Carefully
press the wrench
upwards to engage
with the wrench flats.
Step 2: Carefully press
the wrench upwards to
engage with the wrench
flats.
Figure 3: Installation with Recessed Wrenches
*Requires a 1/2 ratchet - not available from Minimax.
STANDARD FINISHES
WAX COATED 13577W/B*
13655W/B*
MICROMATIC® STANDARD
RESPONSE PENDENT
SPRINKLER VK102 (K5.6)
TECHNICAL DATA
Page 7 of 7
Form No. F_031414 20.10.20 Rev 20.1
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
Installed with a standard 1/8”
surface-mounted escutcheon
Figure 4: Installation Dimensions with Escutcheons
Installed with a Model E-1
Recessed Escutcheon
Installed with a Model E-2 Thread-on
Recessed Escutcheon
Ceiling Opening Size:
2-5/16” (59 mm) minimum
2-1/2” (64 mm) maximum
Ceiling Opening Size:
2-5/16” (59 mm) minimum
2-1/2” (64 mm) maximum
1-1/8” (29 mm)
Minimum
1-1/8” (29 mm)
Minimum1-3/4”
(45 mm)
Maximum
1-3/4”
(45 mm)
2”
(51 mm)
Maximum
2-1/8” (54 mm)2-1/8” (54 mm)
Replaces Form No. F_031414 Rev 19.2
(Revised CE approval)
OFFICE OF THE FIRE MARSHAL – LA QUINTA
78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074
• www.rvcfire.org
October 4, 2021
ACER Fire Protection
4661 Mane Street
Montclair, CA 91763
Re: TI Fire Sprinkler Plan Review – NAIL SALON
FSS2021-0234 / 78670 HIGHWAY 111, LA QUINTA, CA 92253
The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County
Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions.
The following inspections/tests are required to be witnessed by the Office of the Fire Marshal staff:
1) Overhead Rough: All installed/relocated piping must be visible.
2) Final inspection: All trim is in place, 5-Year certification is current. New/added heads shall be
included in the spare head box compliment.
*Water-flow signal test may be performed during the Final Inspection.
All persons performing work on the automatic fire sprinkler system shall be Certified Sprinkler Fitters or
Registered with the State Fire Marshal for Apprentice or Trainee classification.
The Fire Department approved plans and conditions letter must be at the job site.
Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for
inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131.
All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal
staff at (760)777-7074.
Kohl Hetrick - Fire Safety Specialist
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
RIVERSIDE COUNTY FIRE PROTECTION PLANNING
RECORD OF INSPECTIONS / PERMIT CARD
THIS CARD IS TO REMAIN ON SITE AT ALL TIMES.
INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE.
JOB
ADDRESS: 78670 HIGHWAY 111 PERMIT#: FSS2021-0234 DATE
ISSUED: 10/4/2021
DESCRIPTION: NAIL SALON TI CONTRACTOR: ACER FIRE PROTECTION
HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS
Thrust block pre-pour Door fan test
UG rough piping Abort test
UG hydro Mechanical shutdown
Flush Detector test
Final E F Deluge/pre-action
SPRINKLER U.G. Final E F
Thrust block pre-pour UST/AST TANK
UG rough piping Installation
UG hydro Removal
Flush Emergency shut off
Final E F Primary piping
FIRE SPRINKLER Secondary piping
Weld inspection Dispensers & shear valves
Overhead rough piping Final E F
Overhead hydro MISC. INSPECTIONS
UG flush / OK to connect Spray booths
Main drain/inspectors’ test Hood/duct extinguishing
High pile storage High pile rack storage
In-rack sprinklers H.P. vents/access/corridors
Hose racks Tract access/hydrant verification
Final E F Access & Address verification
HOOD EXTINGUISHING OTHER CONST. PERMIT
Detection system
Function test
Gas/electrical shut-off
Nozzle model/placement
Fire alarm connection
Final E F
SPRAY BOOTHS FIRE CODE PERMIT(S)
Installation
Air flow test
Mechanical interlock
Extinguishing system
Fire alarm connection
Final E F
FIRE ALARM KNOX SYSTEM
Rough-wire inspection Building Knox box
Function test Gate access Knox box/padlock
Duct detectors/velocity BUILDING INSPECTIONS
24 hr. battery test T/I final
Sprinkler monitoring Shell final
Final E F Final for occupancy
FINAL INSPECTION DATE: INSPECTORS SIGNATURE:
**WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE**
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
INSPECTION NOTES
1. Sway bracing and hangers will be inspected at the time of rough piping inspection.
2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler
Systems)
3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required.
4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test.
5. Contractor shall supply all testing equipment, access and operating instructions at time of test.
6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the
affected system to be covered or hidden.
POLICIES ON FIELD INSPECTIONS
A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when
scheduling inspections. For City of La Quinta inspections call: (760) 777-7131.
B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence
without approved plans.
C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required
to schedule the necessary inspections and be present on site for inspections.
D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not
on site or where previously noted corrections have not been completed.
E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into
the structure until clearance has been granted by the Fire Dept and Building Official.
F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance
has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official.
INSPECTION NOTES:
THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE
AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS.
THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180
DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE.
THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE
REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.