FSS2021-0245ADDITIONAL SITES
CHRONOLOGY
CONDITION
TYPE CONTACT DATE
ADDED
DATE
REQUIRED
DATE
SATISFIED STATUS REMARKS NOTES
READY TO ISSUE
CHECKLIST
ARMANDO
MAGALLON 10/28/2021 4/4/2022 COMPLETE PENDING BRES ISSUANCE
CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES
NOTE JOSE DELGADO 2/3/2023 2/3/2023
CONTRACTOR REQUESTED FINAL INSPECTION. PERMIT
EXPIRED AS OF 1/29/23 (6 MOS FROM DATE OF LAST
APPROVED INSPECTION). ADDED EXTENSION FEE OF $88 AND
EXTENDED PERMIT TO 2/3/23 SO CONTRACTOR CAN PAY FEE
VIA ETRAKIT. WILL ALSO REQUIRE AN EXTENSION REQUEST
LETTER FROM CONTRACTOR. OK TO EXTEND PER KOHL.
FEES HAVE BEEN PAID AND CONTRACTOR PROVIDED
EXTENSION REQUEST. EXTENDING PERMIT FOR ANOTHER 6
MONTHS.
CONDITIONS
Description: FIRE SPRINKLERS / BRES2021-0508 NOT ISSUED
Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM
HOMES
Status: FINALED Applied: 10/13/2021 ECON
Parcel No: 770103006 Site Address: 50990 CALLE PALOMA LA QUINTA,CA 92253 Approved: 10/28/2021 KHET
Subdivision: DESERT CLUB TR UNIT 5 Block: Lot: 61 Issued: 7/26/2022 ONLINE
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 2/8/2023 LRO
Valuation: $5,000.00 Occupancy Type: Construction Type: Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details:
Printed: Friday, March 03, 2023 9:14:23 AM 1 of 4
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2021-0245
CONTACTS
NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL
APPLICANT J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 (760)625-5908 JCFIREPROTECTION@V
ERIZON.NET
CONTRACTOR J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 (760)625-5908 JCFIREPROTECTION@V
ERIZON.NET
OWNER ROSS MELIN 75443 STARDUST LN INDIAN WELLS CA 00000 (760)625-5908
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED
DATE
COMPLETED
DATE
RESULT REMARKS NOTES
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
FIRE PERMIT
EXTENSION (ADMIN
PROCESSING)
101-0000-42420 0 $88.00 $88.00 2/3/23 WEB14247 808506422 CREDIT 996335 ECON
FIRE SPRINKLER
SYSTEMS - SINGLE
FAMILY DETACHED
101-0000-42421 0 $167.00 $167.00 7/26/22 WEB12595 674411354 CREDIT 996335 ECON
FIRE SPRINKLER
SYSTEMS - SINGLE
FAMILY DETACHED PC
101-0000-42420 0 $250.00 $250.00 7/26/22 WEB12595 674411354 CREDIT 996335 ECON
Total Paid for FIRE FEES: $505.00 $505.00
RECORDS
MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 7/26/22 WEB12595 674411354 CREDIT 996335 ECON
Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00
TECHNOLOGY
ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 7/26/22 WEB12595 674411354 CREDIT 996335 ECON
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
TOTALS:$521.00 $521.00
Printed: Friday, March 03, 2023 9:14:23 AM 2 of 4
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2021-0245
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 10/13/2021 Etrakit Contractor 1ST SUBMITTAL
APPLICATION
FIRE APPLICATION
SEPTEMBER 2019 FEE
UPDATE REVISED 3
copy.pdf
1
DOC 10/13/2021 Etrakit Contractor 1ST SUBMITTAL CPVC
PIPE AND FITTINGS blazemaster.pdf 1
DOC 10/13/2021 Etrakit Contractor 1ST SUBMITTAL HEADS vk 470 Recessed 3.0
k.pdf 1
DOC 10/13/2021 Etrakit Contractor 1ST SUBMITTAL HEADS
2
vk 496 3.0k Flat
Concealed.pdf 1
DOC 10/13/2021 Etrakit Contractor 1ST SUBMITTAL
HANGERS fig28 copy.pdf 1
DOC 10/13/2021 Etrakit Contractor 1ST SUBMITTAL
HANGERS 2
pc-cpvc-double-offset
copy 2.pdf 1
BOND INFORMATION
OVERHEAD HYRO KHET 8/2/2022 8/2/2022 APPROVED
OVERHEAD ROUGH
PIPING KHET 8/2/2022 8/2/2022 APPROVED SEE NOTES
As-builts required.
Confirm at final: Domestic connection,
clearance from smoke detectors.
FIRE FINAL**LRO 2/8/2023 2/8/2023 APPROVED
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED
DATE
STATUS REMARKS NOTES
1ST FIRE - ETRAKIT
(2 WK)
KOHL
HETRICK 10/13/2021 10/27/2021 10/28/2021 APPROVED-
CONDITIONS
SEE ATTACHMENTS
1ST PERMIT TECH –
ETRAKIT (1 DAY)
PERMIT TECH
BUCKET
10/13/2021 10/14/2021 10/13/2021 COMPLETE
PARENT PROJECTS
Printed: Friday, March 03, 2023 9:14:23 AM 3 of 4
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2021-0245
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 10/13/2021 Etrakit Contractor 1ST SUBMITTAL CPVC
CHECK VALVE
spears cpvc check valve
page.28 copy.pdf 1
DOC 10/13/2021 Etrakit Contractor 1ST SUBMITTAL FS PLAN Calle Paloma Residence
Fire Sprinklers .pdf 1
DOC 10/13/2021 Etrakit Contractor 1ST SUBMITTAL SITE
PLAN A1 SITE PLAN.pdf 1
DOC 10/13/2021 Etrakit Contractor 1ST SUBMITTAL CALCS
AREA 1 AREA 1 1HD.PDF 1
DOC 10/13/2021 Etrakit Contractor 1ST SUBMITTAL CALCS
AREA 2 AREA 2 2HD.PDF 1
DOC 10/13/2021 Etrakit Contractor 1ST SUBMITTAL RCCE
Scanned from a Xerox
Multifunction Printer-8
copy.pdf
1
DOC 2/3/2023 Etrakit Contractor AS BUILT
as built FSS2021-0245 -
8-2-2022 INSP
NOTES.pdf
1
DOC 2/3/2023 JOSE DELGADO LETTER FOR FSS2021-
0245.pdf
LETTER FOR FSS2021-
0245.pdf 0
DOC 10/28/2021 KOHL HETRICK
FSS2021-0245 -
APPROVED PLANS AND
CALCS.pdf
FSS2021-0245 -
APPROVED PLANS AND
CALCS.pdf
1
DOC 10/28/2021 KOHL HETRICK FSS2021-0245 - COA
AND JOB CARD.pdf
FSS2021-0245 - COA
AND JOB CARD.pdf 1
DOC 8/2/2022 KOHL HETRICK FSS2021-0245 - 8-2-2022
INSP NOTES.pdf
FSS2021-0245 - 8-2-2022
INSP NOTES.pdf 1
Printed: Friday, March 03, 2023 9:14:23 AM 4 of 4
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2021-0245
FSS2021-0245
FSS2021-0245
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1DATE: 10/12/2021LE PALOMA RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1HD.SDFJOB TITLE: AREA 1 1HD (16x16)(15 GPM) WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ’D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) M (N/A) 64.1 (N/A) 64.1 20.0 46.4 Available pressure is 17.7 psi (28%) greater than required pressure.
AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 20.0 GPMTOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPMOTHER HOSE STREAM ALLOWANCES 5.0 GPMTOTAL DISCHARGE FROM ACTIVE SPRINKLERS 15.0 GPM
NODE ANALYSIS DATANODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM)
P1 10.0 K= 3.00 25.0 15.0P2 10.0 - - - - 25.3 - - -P3 10.0 - - - - 25.3 - - -1 10.5 - - - - 25.0 - - -2 10.5 - - - - 25.0 - - -3 10.5 - - - - 25.0 - - -A 10.5 - - - - 25.0 - - -B 10.5 - - - - 25.5 - - -C 10.5 - - - - 29.8 - - -C1 10.5 - - - - 29.3 - - -D 12.5 - - - - 29.8 - - -D1 10.5 - - - - 31.3 - - -E 10.5 - - - - 32.1 - - -TOR 10.5 - - - - 32.5 - - -FS1 4.0 - - - - 35.7 - - -FS2 4.0 - - - - 38.7 - - -BOR 0.5 - - - - 40.9 - - -DOM 0.5 HOSE STREAM 41.7 5.0UG -3.0 - - - - 43.4 - - -M -3.0 SOURCE 46.4 20.0
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2DATE: 10/12/2021LE PALOMA RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1HD.SDFJOB TITLE: AREA 1 1HD (16x16)(15 GPM) PIPE DATA
PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 1 -15.0 1.101 PL 0.50 PF 0.3P1 10.0 3.0 25.0 15.0 5.1 150 FTG T PE -0.21 10.5 0.0 25.0 0.0 0.040 TL 6.50 PV
Pipe: 2 0.0 1.101 PL 0.50 PF 0.0P2 10.0 0.0 25.3 0.0 0.0 150 FTG E PE -0.22 10.5 0.0 25.0 0.0 0.000 TL 7.50 PV
Pipe: 3 0.0 1.101 PL 0.50 PF 0.0P3 10.0 0.0 25.3 0.0 0.0 150 FTG T PE -0.23 10.5 0.0 25.0 0.0 0.000 TL 6.50 PV
Pipe: 5 0.0 1.101 PL 4.75 PF 0.02 10.5 0.0 25.0 0.0 0.0 150 FTG T PE 0.0A 10.5 0.0 25.0 0.0 0.000 TL 10.75 PV
Pipe: 6 0.0 1.101 PL 3.25 PF 0.03 10.5 0.0 25.0 0.0 0.0 150 FTG T PE 0.0A 10.5 0.0 25.0 0.0 0.000 TL 9.25 PV
Pipe: 7 0.0 1.101 PL 12.50 PF 0.0A 10.5 0.0 25.0 0.0 0.0 150 FTG 2R PE 0.01 10.5 0.0 25.0 0.0 0.000 TL 15.90 PV
Pipe: 8 -15.0 1.101 PL 4.00 PF 0.41 10.5 0.0 25.0 0.0 5.1 150 FTG E PE 0.0B 10.5 0.0 25.5 0.0 0.040 TL 11.00 PV
Pipe: 8A -15.0 0.957 PL 42.25 PF 3.8B 10.5 0.0 25.5 0.0 6.7 150 FTG 3E PE 0.0C1 10.5 0.0 29.3 0.0 0.079 TL 48.05 PV
Pipe: 8B -15.0 1.101 PL 5.75 PF 0.5C1 10.5 0.0 29.3 0.0 5.1 150 FTG TR PE 0.0C 10.5 0.0 29.8 0.0 0.040 TL 13.45 PV
Pipe: 9 -8.1 1.101 PL 46.75 PF 0.9C 10.5 0.0 29.8 0.0 2.7 150 FTG 2E5R PE -0.9D 12.5 0.0 29.8 0.0 0.013 TL 69.25 PV
Pipe: 10 -8.1 1.101 PL 67.75 PF 1.3D 12.5 0.0 29.8 0.0 2.7 150 FTG 2E2T7R PE 0.9E 10.5 0.0 32.1 0.0 0.013 TL 105.65 PV
Pipe: 11 -6.9 1.101 PL 90.50 PF 1.4C 10.5 0.0 29.8 0.0 2.3 150 FTG 4E3T9R PE 0.0D1 10.5 0.0 31.3 0.0 0.010 TL 151.80 PV
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3DATE: 10/12/2021LE PALOMA RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1HD.SDFJOB TITLE: AREA 1 1HD (16x16)(15 GPM) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 12 -6.9 1.101 PL 55.50 PF 0.8D1 10.5 0.0 31.3 0.0 2.3 150 FTG ET8R PE 0.0E 10.5 0.0 32.1 0.0 0.010 TL 82.10 PV
Pipe: 14 -15.0 1.101 PL 4.50 PF 0.5E 10.5 0.0 32.1 0.0 5.1 150 FTG E PE 0.0TOR 10.5 0.0 32.5 0.0 0.040 TL 11.50 PV
Pipe: 15 -15.0 1.101 PL 6.50 PF 0.3TOR 10.5 0.0 32.5 0.0 5.1 150 FTG R PE 2.8FS1 4.0 0.0 35.7 0.0 0.040 TL 8.20 PV
Pipe: 16 FIXED PRESSURE LOSS DEVICEFS2 4.0 0.0 38.7 0.0 3.0 psi, 15.0 gpmFS1 4.0 0.0 35.7 0.0
Pipe: 17 -15.0 1.101 PL 3.50 PF 0.7FS2 4.0 0.0 38.7 0.0 5.1 150 FTG EC PE 1.5BOR 0.5 0.0 40.9 0.0 0.040 TL 18.50 PV
Pipe: 18 -15.0 1.055 PL 2.00 PF 0.8BOR 0.5 0.0 40.9 0.0 5.5 150 FTG 2ET PE 0.0DOM 0.5 H.S. 41.7 5.0 0.049 TL 16.00 PV
Pipe: 19 -20.0 1.291 PL 3.50 PF 0.2DOM 0.5 H.S. 41.7 5.0 4.9 150 FTG EG PE 1.5UG -3.0 0.0 43.4 0.0 0.031 TL 7.50 PV
Pipe: 20 -20.0 1.278 PL 80.00 PF 2.9UG -3.0 0.0 43.4 0.0 5.0 150 FTG 3E PE 0.0M -3.0 SRCE 46.4 (N/A) 0.033 TL 89.36 PV
NOTES (HASS):
(1) Calculations were performed by the HASS 2020 D computer program in accordance with NFPA13 (2016) under license no. 64622225 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760
(2) The system has been calculated to provide an average imbalance at each node of 0.003 gpm and a maximum imbalance at any node of 0.057 gpm.
(3) Total pressure at each node is used in balancing the system. Maximum water velocity is 6.7 ft/sec at pipe 8A.
(4) Items listed in bold print on the cover sheet
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4DATE: 10/12/2021LE PALOMA RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1HD.SDFJOB TITLE: AREA 1 1HD (16x16)(15 GPM) are automatically transferred from the calculation report.
(5) PIPE FITTINGS TABLE
HASS Pipe Table Name: standard.pip
PAGE: F MATERIAL: CPVC HWC: 150Diameter Equivalent Fitting Lengths in Feet (in) F E T R K C G F45 Ell Tee RunT Kplg ChkVlv Gate 1.101 1.40 7.00 6.00 1.70 1.00 8.00 0.40
PAGE: M MATERIAL: CT-M HWC: 150Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Ell Tee 45-Ell TeeRun Kouplg ChkVlv GatVlv NPTee 1.055 3.00 8.00 2.00 3.00 0.00 8.00 0.00 8.00 1.291 3.00 7.00 1.00 2.00 0.50 8.00 0.00 7.00
PAGE: * MATERIAL: S40 HWC: 120Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee -------------------------------------------------------- F F45Ell 0.957 1.28 3.20 1.28 3.20 3.84 0.64 6.40 1.28 3.20 0.64 1.278 2.06 4.13 1.38 4.82 4.13 0.69 6.88 6.88 4.13 1.03
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5DATE: 10/12/2021LE PALOMA RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1HD.SDFJOB TITLE: AREA 1 1HD (16x16)(15 GPM) WATER SUPPLY ANALYSIS
Fixed Source Pressure: 64.10 psi
-14.7
0.0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
600 900 1200 1500 1800 2100 2400 2700 3000
FLOW (GPM)
Note: (1) Dashed Lines indicate extrapolated values from Test Results
G
A
U
G
E
P
R
E
S
S
U
R
E
(
p
s
i
)
A1
2
B
LEGEND
1 Available pressure
64.10 psi @ 20.0 gpm
2 Required pressure
46.39 psi @ 20.0 gpm
A. Source Supply Curve
B. System Demand Curve
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6DATE: 10/12/2021LE PALOMA RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1HD.SDFJOB TITLE: AREA 1 1HD (16x16)(15 GPM) WATER SUPPLY CURVE 72+ | | | 66+ 0\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ | | 60+ | | | 54+ | | | P 48+ R X E | S | S 42+ U | R | E | 36+ ( | P | S | I 30+ ) | | | 24+ | | | 18+ | | |============================== 12+ LEGEND " | " | X = Required Water Supply " | 46.39 psi @ 20.0 gpm " 6+ " | 0 = Available Water Supply " | 64.10 psi @ 20.0 gpm " | " 0++-+---+----+-----+------+--------+--------+---------+-----------+ 8001200 1600 2000 2400 2800 3200 3600 4000 FLOW (GPM)
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1DATE: 10/12/2021LE PALOMA RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2HD.SDFJOB TITLE: AREA 2 2HD (12x12)(8 GPM) WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ’D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) M (N/A) 64.1 (N/A) 64.1 21.0 30.7 Available pressure is 33.4 psi (52%) greater than required pressure.
AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 21.0 GPMTOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPMOTHER HOSE STREAM ALLOWANCES 5.0 GPMTOTAL DISCHARGE FROM ACTIVE SPRINKLERS 16.0 GPM
NODE ANALYSIS DATANODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM)
P1 10.0 - - - - 8.1 - - -P2 10.0 K= 3.00 7.1 8.0P3 10.0 K= 3.00 7.1 8.01 10.5 - - - - 7.8 - - -2 10.5 - - - - 7.0 - - -3 10.5 - - - - 7.0 - - -A 10.5 - - - - 7.1 - - -B 10.5 - - - - 8.3 - - -C 10.5 - - - - 13.2 - - -C1 10.5 - - - - 12.6 - - -D 12.5 - - - - 13.4 - - -D1 10.5 - - - - 14.9 - - -E 10.5 - - - - 15.8 - - -TOR 10.5 - - - - 16.3 - - -FS1 4.0 - - - - 19.5 - - -FS2 4.0 - - - - 22.5 - - -BOR 0.5 - - - - 24.8 - - -DOM 0.5 HOSE STREAM 25.7 5.0UG -3.0 - - - - 27.5 - - -M -3.0 SOURCE 30.7 21.0
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2DATE: 10/12/2021LE PALOMA RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2HD.SDFJOB TITLE: AREA 2 2HD (12x12)(8 GPM) PIPE DATA
PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 1 0.0 1.101 PL 0.50 PF 0.0P1 10.0 0.0 8.1 0.0 0.0 150 FTG T PE -0.21 10.5 0.0 7.8 0.0 0.000 TL 6.50 PV
Pipe: 2 -8.0 1.101 PL 0.50 PF 0.1P2 10.0 3.0 7.1 8.0 2.7 150 FTG E PE -0.22 10.5 0.0 7.0 0.0 0.012 TL 7.50 PV
Pipe: 3 -8.0 1.101 PL 0.50 PF 0.1P3 10.0 3.0 7.1 8.0 2.7 150 FTG T PE -0.23 10.5 0.0 7.0 0.0 0.013 TL 6.50 PV
Pipe: 5 -8.0 1.101 PL 4.75 PF 0.12 10.5 0.0 7.0 0.0 2.7 150 FTG T PE 0.0A 10.5 0.0 7.1 0.0 0.012 TL 10.75 PV
Pipe: 6 -8.0 1.101 PL 3.25 PF 0.13 10.5 0.0 7.0 0.0 2.7 150 FTG T PE 0.0A 10.5 0.0 7.1 0.0 0.013 TL 9.25 PV
Pipe: 7 -16.0 1.101 PL 12.50 PF 0.7A 10.5 0.0 7.1 0.0 5.4 150 FTG 2R PE 0.01 10.5 0.0 7.8 0.0 0.045 TL 15.90 PV
Pipe: 8 -16.0 1.101 PL 4.00 PF 0.51 10.5 0.0 7.8 0.0 5.4 150 FTG E PE 0.0B 10.5 0.0 8.3 0.0 0.045 TL 11.00 PV
Pipe: 8A -16.0 0.957 PL 42.25 PF 4.3B 10.5 0.0 8.3 0.0 7.1 150 FTG 3E PE 0.0C1 10.5 0.0 12.6 0.0 0.089 TL 48.05 PV
Pipe: 8B -16.0 1.101 PL 5.75 PF 0.6C1 10.5 0.0 12.6 0.0 5.4 150 FTG TR PE 0.0C 10.5 0.0 13.2 0.0 0.045 TL 13.45 PV
Pipe: 9 -8.6 1.101 PL 46.75 PF 1.0C 10.5 0.0 13.2 0.0 2.9 150 FTG 2E5R PE -0.9D 12.5 0.0 13.4 0.0 0.014 TL 69.25 PV
Pipe: 10 -8.6 1.101 PL 67.75 PF 1.5D 12.5 0.0 13.4 0.0 2.9 150 FTG 2E2T7R PE 0.9E 10.5 0.0 15.8 0.0 0.014 TL 105.65 PV
Pipe: 11 -7.4 1.101 PL 90.50 PF 1.6C 10.5 0.0 13.2 0.0 2.5 150 FTG 4E3T9R PE 0.0D1 10.5 0.0 14.9 0.0 0.011 TL 151.80 PV
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3DATE: 10/12/2021LE PALOMA RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2HD.SDFJOB TITLE: AREA 2 2HD (12x12)(8 GPM) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 12 -7.4 1.101 PL 55.50 PF 0.9D1 10.5 0.0 14.9 0.0 2.5 150 FTG ET8R PE 0.0E 10.5 0.0 15.8 0.0 0.011 TL 82.10 PV
Pipe: 14 -16.0 1.101 PL 4.50 PF 0.5E 10.5 0.0 15.8 0.0 5.4 150 FTG E PE 0.0TOR 10.5 0.0 16.3 0.0 0.045 TL 11.50 PV
Pipe: 15 -16.0 1.101 PL 6.50 PF 0.4TOR 10.5 0.0 16.3 0.0 5.4 150 FTG R PE 2.8FS1 4.0 0.0 19.5 0.0 0.045 TL 8.20 PV
Pipe: 16 FIXED PRESSURE LOSS DEVICEFS2 4.0 0.0 22.5 0.0 3.0 psi, 16.0 gpmFS1 4.0 0.0 19.5 0.0
Pipe: 17 -16.0 1.101 PL 3.50 PF 0.8FS2 4.0 0.0 22.5 0.0 5.4 150 FTG EC PE 1.5BOR 0.5 0.0 24.8 0.0 0.045 TL 18.50 PV
Pipe: 18 -16.0 1.055 PL 2.00 PF 0.9BOR 0.5 0.0 24.8 0.0 5.9 150 FTG 2ET PE 0.0DOM 0.5 H.S. 25.7 5.0 0.056 TL 16.00 PV
Pipe: 19 -21.0 1.291 PL 3.50 PF 0.3DOM 0.5 H.S. 25.7 5.0 5.2 150 FTG EG PE 1.5UG -3.0 0.0 27.5 0.0 0.034 TL 7.50 PV
Pipe: 20 -21.0 1.278 PL 80.00 PF 3.2UG -3.0 0.0 27.5 0.0 5.3 150 FTG 3E PE 0.0M -3.0 SRCE 30.7 (N/A) 0.036 TL 89.36 PV
NOTES (HASS):
(1) Calculations were performed by the HASS 2020 D computer program in accordance with NFPA13 (2016) under license no. 64622225 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760
(2) The system has been calculated to provide an average imbalance at each node of 0.004 gpm and a maximum imbalance at any node of 0.072 gpm.
(3) Total pressure at each node is used in balancing the system. Maximum water velocity is 7.1 ft/sec at pipe 8A.
(4) Items listed in bold print on the cover sheet
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4DATE: 10/12/2021LE PALOMA RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2HD.SDFJOB TITLE: AREA 2 2HD (12x12)(8 GPM) are automatically transferred from the calculation report.
(5) PIPE FITTINGS TABLE
HASS Pipe Table Name: standard.pip
PAGE: F MATERIAL: CPVC HWC: 150Diameter Equivalent Fitting Lengths in Feet (in) F E T R K C G F45 Ell Tee RunT Kplg ChkVlv Gate 1.101 1.40 7.00 6.00 1.70 1.00 8.00 0.40
PAGE: M MATERIAL: CT-M HWC: 150Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Ell Tee 45-Ell TeeRun Kouplg ChkVlv GatVlv NPTee 1.055 3.00 8.00 2.00 3.00 0.00 8.00 0.00 8.00 1.291 3.00 7.00 1.00 2.00 0.50 8.00 0.00 7.00
PAGE: * MATERIAL: S40 HWC: 120Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee -------------------------------------------------------- F F45Ell 0.957 1.28 3.20 1.28 3.20 3.84 0.64 6.40 1.28 3.20 0.64 1.278 2.06 4.13 1.38 4.82 4.13 0.69 6.88 6.88 4.13 1.03
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5DATE: 10/12/2021LE PALOMA RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2HD.SDFJOB TITLE: AREA 2 2HD (12x12)(8 GPM) WATER SUPPLY ANALYSIS
Fixed Source Pressure: 64.10 psi
-14.7
0.0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
600 900 1200 1500 1800 2100 2400 2700 3000
FLOW (GPM)
Note: (1) Dashed Lines indicate extrapolated values from Test Results
G
A
U
G
E
P
R
E
S
S
U
R
E
(
p
s
i
)
A1
2
B
LEGEND
1 Available pressure
64.10 psi @ 21.0 gpm
2 Required pressure
30.70 psi @ 21.0 gpm
A. Source Supply Curve
B. System Demand Curve
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6DATE: 10/12/2021LE PALOMA RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2HD.SDFJOB TITLE: AREA 2 2HD (12x12)(8 GPM) WATER SUPPLY CURVE 72+ | | | 66+ 0\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ | | 60+ | | | 54+ | | | P 48+ R | E | S | S 42+ U | R | E | 36+ ( | P | S | I 30X ) | | | 24+ | | | 18+ | | |============================== 12+ LEGEND " | " | X = Required Water Supply " | 30.70 psi @ 21.0 gpm " 6+ " | 0 = Available Water Supply " | 64.10 psi @ 21.0 gpm " | " 0++-+---+----+-----+------+--------+--------+---------+-----------+ 8001200 1600 2000 2400 2800 3200 3600 4000 FLOW (GPM)
FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS
27 SPEARS® MANUFACTURING COMPANY
CPVC SPECIAL REINFORCED
THREAD INLET SWING CHECK VALVES
SR Fipt x Socket
A
B
C
D
Part Number Size A B C D Approx. Wt. (Lbs)
S1520-10FSRSCO 1 1-11/16 2-15/16 4-9/16 2-5/8 .33
S1520-12FSRSCO 1-1/4 2-1/16 3-5/8 5-1/2 3-3/8 .42
S1520-15FSRSCO 1-1/2 2-7/16 3-11/16 5-5/8 3-3/8 .89
Not UL Listed
CPVC SWING CHECK VALVES
Socket x Socket
Part Number Size A B C D Approx. Wt. (Lbs)
S1520-10CO 1 1-11/16 2-5/16 4-9/16 2-5/8 .33
S1520-12CO 1-1/4 2-1/16 2-15/16 5-1/2 3-3/8 .42
S1520-15CO 1-1/2 2-7/16 3 5-5/8 3-3/8 .89
Not UL Listed
A
B
C
D
COMPACT 2000 DRAIN VALVE
Socket x Socket
Part Number Size A B C D E
6622-007CO 3/4 1-13/16 1-1/2 3-9/16 2 3
6622-010CO 1 2-1/16 1-3/4 4 2-5/16 3-7/16
Not UL Listed
D
E
A
B
C
OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330
CUSTOMER SERVICE • 800.786.5266
www.tolco.com
42
www.tolco.com
Revision 1/21/2011
Fig. 28 - "Stand-Off" Hanger & Restrainer for
CPVC Plastic Pipe
Size Range — ¾" through 2"
Material — Carbon Steel, Pre-Galvanized
Function — Designed to be used as a hanger and restrainer for CPVC piping where
the "stand-off" design will ease installation by eliminating the need for wood blocking.
Features:
• Flared edge design protects CPVC pipe from any rough or abrasive surfaces.
• Unique twist and lock design holds pipe firmly in place and allows retrofit type
of installation.
• The "Stand-Off" design eliminates the need for wood block extension.
• Can be installed on horizontal or vertical piping regardless of mounting
surface orientation.
• Attaches easily to wood structure with two hex head self-threading screws
furnished with product.
• Installs easily using rechargeable electrical driver with 5/16" extension socket
eliminating impact tool damage to pipe.
• Attaches easily to steel, minimum 18 gauge with (2) 1/4" x 1" tek type self drilling
tapping screws.
• UL Listed as a hanger and a restrainer for fire sprinkler piping.
Approvals — Underwriters' Laboratory Listed in the USA (UL) and Canada (cUL) to
support automatic fire sprinkler systems. May be installed into wood using fasteners
supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1" tek type
screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satis-
fies the UL vertical restraint requirement where needed. UL Listed as a hanger and ver-
tical restraint when installed on 3/8" composite wood material. Use two Fig. 27B Speed
Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper
installed screw when used as a hanger only.
Order by — Figure number and pipe size.
Pat. # 7,455,268, Pat. # 7,832,248
Dimensions • Weights
Pipe Approx.
Size A B C Wt.
3/4 31⁄32 2 31⁄2 .180
1 35⁄16 23⁄16 31⁄2 .210
11⁄4 35⁄8 23⁄8 31⁄2 .225
11⁄2 4 21⁄2 31⁄2 .310
2 41⁄2 211⁄16 35⁄8 .340
TOLCO™Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe
Size Range:Available in 3/4"(20mm)and 1"(25mm)pipe sizes
Material:Pre-Galvanized Steel
Function:Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler
pipe. Provides double offset 11/2”(20mm)x 11/2”(20mm)from mounting surface. This design
will ease installation by eliminating the need for wood block extension and allow retro-fit
attachment of hanger to sprinkler pipe.
Features:
• Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not
required to be bent for listed installation.
• Offset edge eliminates abrasion.
• Attaches easily to wood structure with two special #10 x 1” hex head self-threading
screws furnished with product.
• Can be used as a single offset hanger by aligning "dimples" with top of mounting
surface and utilizing two fasteners in two of the three holes provided.
Approvals:Underwriters Laboratories Listed in the USA (UL)and Canada (cUL)as a
hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of
NFPA 13, 13R and 13D.
Finish:Pre-Galvanized
Order By:Part number and pipe size.
Patent Pending
Install using a rechargeable electric drill fitted with a 5/16” (7.9mm)socket attachment with the special hex head self-tapping
screws provided. Install screws until they bottom out. Pipe can be “snapped” into hanger before or after installation of
the screws to the mounting surface. “Thumb tab” may be bent up to provide additional protection to the pipe, but is not
required for performance of the hanger / restrainer function.
Double Offset
Single Offset
1.5”
(38.1mm)
1.5”
(38.1mm)
1.5”
(38.1mm)
1.5”
(38.1mm)Pipe Clamps Pipe Clamps
Pipe Size Approx. Wt./100
Part No.in. (mm) lbs. (kg)
29-3/4 3/4"(20)17.0 (7.7)
29-1 1"(25)18.6 (8.4)
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
103 B-Line series Pipe Hangers & SupportsEaton
TECHNICAL DATA
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
FREEDOM® RESIDENTIAL
PENDENT SPRINKLER
VK470 (K3.0)
Form No. F_061011 Rev 14.1
Page 1 of 5
1. DESCRIPTION
Viking Freedom® Residential Pendent Sprinkler VK470 is a thermosensitive, glass-bulb residen-
tial sprinkler available in several different finishes and temperature ratings to meet varying de-
sign requirements. The Electroless Nickel PTFE (ENT) coating has been investigated for instal-
lation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated
in the Approval Chart. The sprinkler orifice design, with a K-Factor of 3.0 (43.2 metric*), allows
efficient use of available water supplies for the hydraulically designed fire-protection system.
The glass bulb operating element and special deflector characteristics meet the challenges of
residential sprinkler standards.
2. LISTINGS AND APPROVALS
UL Listed (C-UL-US-EU): Category VKKW
Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements
that must be followed.
3. TECHNICAL DATA
6SHFL¿FDWLRQV
Avaiilable since 2012.
Minimum Operating Pressure: Refer to the Approval Chart.
Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically
to 500 psi (34.5 bar).
Thread size: 1/2” (15 mm) NPT
Nominal K-Factor: 3.0 U.S. (43.2 metric*)
* Metric K-factor measurement shown is in Bar. When pressure is measured in kPa,
divide the metric K-factor shown by 10.0.
Glass-bulb fluid temperature rated to -65 °F (-55 °C)
Overall Length: 2-1/4” (58 mm)
Material Standards:
Frame Casting: QM Brass
Deflector: Phosphor Bronze UNS-C51000 or Brass UNS-C23000
Bulb: Glass, nominal 3 mm diameter
Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape
Compression Screw: Brass UNS-C36000
Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400
For ENT coated sprinklers: Belleville spring - Exposed, Screw and Pipcap - ENT plated.
Ordering Information: (Also refer to the current Viking price list.)
Sprinkler: Base Part No. 17147
Order Sprinkler VK470 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the tempera-
ture rating to the sprinkler base part number.
Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN
Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D
For example, sprinkler VK470 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 17147AB.
Available Finishes And Temperature Ratings: Refer to Table 1.
Accessories: (Also refer to the “Sprinkler Accessories” section of the Viking data book.)
Sprinkler Wrenches:
A. Standard Wrench: Part No. 10896W/B (available since 2000)
B. Wrench for Recessed Sprinklers: Part No. 16036W/B** (available since 2011)
C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010.)
**A ½” ratchet is required (not available from Viking).
***Allows use from the floor by attaching a length of 1” diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808.
Sprinkler Cabinets:
A. Six-head capacity: Part No. 01724A (available since 1971)
B. Twelve-head capacity: Part No. 01725A (available since 1971)
(Added EU Listing)
Viking Technical Data may be found on
The Viking Corporation’s Web site at
http://www.vikinggroupinc.com.
The Web site may include a more recent
edition of this Technical Data Page.
TECHNICAL DATA
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
FREEDOM® RESIDENTIAL
PENDENT SPRINKLER
VK470 (K3.0)
Form No. F_061011 Rev 14.1
Page 2 of 5
4. INSTALLATION
Refer to appropriate NFPA Installation Standards.
5. OPERATION
During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and
sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern
to extinguish or control the fire.
6. INSPECTIONS, TESTS AND MAINTENANCE
Refer to NFPA 25 for Inspection, Testing and Maintenance requirements.
7. AVAILABILITY
The Viking Model VK470 Sprinkler is available through a network of domestic and international distributors. See The Viking
Corporation web site for the closest distributor or contact The Viking Corporation.
8. GUARANTEE
For details of warranty, refer to Viking’s current list price schedule or contact Viking directly.
TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES
Sprinkler Temperature
Classification
Sprinkler Nominal
Temperature Rating1
Maximum Ambient
Ceiling Temperature2 Bulb Color
Ordinary 155 °F (68 °C) 100 °F (38 °C) Red
Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow
Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT
Corrosion Resistant Coatings3: ENT
Footnotes
1 The sprinkler temperature rating is stamped on the deflector.
2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction.
Refer to specific installation standards.
3 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These
tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat-
ible with or suitable for the proposed environment. For ENT coated sprinklers, the waterway is coated. Note that the spring is exposed on sprinklers
with ENT coating.
Figure 1: Standard Sprinkler Wrench 10896W/B
TECHNICAL DATA
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
FREEDOM® RESIDENTIAL
PENDENT SPRINKLER
VK470 (K3.0)
Form No. F_061011 Rev 14.1
Page 3 of 5
Approval Chart
Viking VK470, 3.0 K-Factor Residential Pendent Sprinkler
For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to
NFPA 13, 13R or 13D 2013 Editions
Sprinkler Base
Part Number 1 SIN
NPT Thread Size Nominal K-Factor Maximum Water
Working Pressure
Overall Length
Inches mm U.S. metric
2 Inches mm
17147 VK470 1/2 15 3.0 43.2 175 psi (12 bar) 2-1/4 58
Max. Coverage
Area 4
Ft.X Ft.
(m X m)
Ordinary Temp Rating
(155 °F/68 °C)
Intermediate Temp
Rating (175 °F/79 °C)Deflector
to
Ceiling
Installation
Type
Listings and Approvals 3
Minimum
Spacing
Ft.
(m)
Flow 4
GPM
(L/min)
Pressure 4
PSI
(bar)
Flow 4
GPM
(L/min)
Pressure 4
PSI
(bar)
5
NYC NSF
12 X 12
(3.7 X 3.7)
8
(30.3)
7.11
(0.49)
8
(30.3)
7.11
(0.49)
1-1/8 to 2
inch
Standard
surface-
mounted
escutch-
eons, the
Microfast®
Model F-1
Adjustable
Escutcheon,
or recessed
with the
Micromatic®
Model
E-1, E-
2, or E-3
Recessed
Escutcheon
See
Footnotes
6 and 9
See
Foot-
note 7
--8
(2.4)
14 X 14
(4.3 X 4.3)
10
(37.9)
11.11
(0.77)
10
(37.9)
11.11
(0.77)
16 X 16
(4.9 X 4.9)
13
(49.2)
18.8
(1.29)
13
(49.2)
18.8
(1.29)
Footnotes
1 Part number shown is the base part number. For complete part number, refer to Viking’s current price schedule.
2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-
factor shown by 10.0.
3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the
manufacturer for any additional approvals. Refer also to Design Criteria.
4 For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed
are per sprinkler.
5 Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union.
6 Approved Finishes are: Brass, Chrome, White Polyester, and Black Polyester 8.
7 Meets New York City requirements, effective July 1, 2008.
8 Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors.
9 Approved finish is Electroless Nickel PTFE (ENT). ENT is C-UL-US-EU Listed as corrosion resistant. ENT is available with standard
surface-mounted escutcheons or the Micromatic Model E-1 Recessed Escutcheon.
5
TECHNICAL DATA
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
FREEDOM® RESIDENTIAL
PENDENT SPRINKLER
VK470 (K3.0)
Form No. F_061011 Rev 14.1
Page 4 of 5
DESIGN CRITERIA
(Also refer to the Approval Chart.)
UL Listing Requirements (C-UL-US-EU):
When using Viking Residential Pendent Sprinkler VK470 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and
minimum water supply requirements shown in the Approval Chart.
For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The mini-
mum required discharge from each of the four sprinklers is to be the greater of the following:
The flow rates given in the Approval Chart for NFPA 13D and NFPA13R applications for each listed area of coverage, or
Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13.
Minimum distance between residential sprinklers: 8 ft. (2.4 m).
IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to pages RES1-17 for
general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest
edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction,
and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and
acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction.
Figure 3: Sprinkler VK470 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon
Figure 2: Wrench 16036W/B for Installing Recessed Sprinkler VK470
TECHNICAL DATA
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
FREEDOM® RESIDENTIAL
PENDENT SPRINKLER
VK470 (K3.0)
Form No. F_061011 Rev 14.1
Page 5 of 5
Figure 4: Sprinkler VK470 Dimensions with the Model E-1 and E-2 Recessed Escutcheons
(Added EU Listing)
FREEDOM® RESIDENTIAL
CONCEALED PENDENT
SPRINKLER VK496 (K3.0)TECHNICAL DATA
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
Page 1 of 5
Form No. F_032218 19.03.21 Rev 19.1
1. DESCRIPTION
Viking Freedom® Residential Concealed Pendent Sprinkler VK496 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 3.0 (43.2 metric*), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards.
The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile small-diameter cover assembly installed flush to the ceiling. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “push-on”, “thread-off” design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2” (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated.
2. LISTINGS AND APPROVALS
UL Listed (C-UL-US-EU): Category VKKW
Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing
requirements that must be followed.
3. TECHNICAL DATASpecifications:Minimum Operating Pressure: Refer to the Approval Chart.Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar).Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 3.0 U.S. (43.2 metric*)Glass-bulb fluid temperature rated to -65 °F (-55 °C)
* Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric
K-factor shown by 10.0.
Material Standards:Sprinkler Body: Brass UNS-C84400 or QM BrassDeflector: Phosphor Bronze UNS-C51000Deflector Pins: Stainless Steel UNS-S30200Button: Brass UNS-C31600Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400Compression Screw: 18-8 Stainless SteelYoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-C51000Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE TapeCover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc PlatingShipping Cap: PolyethyleneCover Plate Materials:Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800Spring: Beryllium NickelSolder: Eutectic
Available Finishes and Temperature Ratings:
Finish Brass ENT
Suffix A JN
Temperature 155 °F (68 °C)200°F (93 °C)
Suffix B E
Ordering Information: Refer to Tables 1 and 2.
New page.
FREEDOM® RESIDENTIAL
CONCEALED PENDENT
SPRINKLER VK496 (K3.0)TECHNICAL DATA
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
Page 2 of 5
Form No. F_032218 19.03.21 Rev 19.1
4. INSTALLATION
Refer to appropriate NFPA Installation Standards.
5. OPERATION
During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pressure at the sprinkler to extinguish or control the fire.
6. INSPECTIONS, TESTS AND MAINTENANCERefer to NFPA 25 for Inspection, Testing and Maintenance requirements.
7. AVAILABILITY
Viking Sprinkler Model VK496 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation.
8. GUARANTEEFor details of warranty, refer to Viking’s current list price schedule or contact Viking directly.
TABLE 1: ORDERING INFORMATION
Instructions: Using the sprinkler base part number,
(1) add the suffix for the desired Finish
(2) add the suffix for the desired Temperature Rating.
(3) Order a cover plate (refer to Table 2)
Sprinkler
Base Part
No.
Size 1: Finishes 2: Temperature Ratings
NPT
Inch
BSPT
mm Description Suffix1 Nominal Rating Bulb Color Max. Ambient Ceiling
Temperature2 Suffix
22773 1/2 --Brass A 155 °F (68 °C)Red 100 °F (38 °C)B
ENT 3,4 JN 200 °F (93 °C)Green 150 °F (65 °C)E
Example: 22773AE =
200 °F (93 °C) Temperature Rated Sprinkler
with a standard Brass finish.
Accessories
Sprinkler Wrenches (see Figure 1):
A. Heavy Duty Part Number: 14047WB5
B. Head Cabinet Wrench Part Number: 140316
Sprinkler Cabinet:
Part number 01731A.
Footnotes
1. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above.
2. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having
Jurisdiction. Refer to specific installation standards.
3. UL Listed as corrosion resistant.
4. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and
do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed
environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway.
5. Requires a 1/2” ratchet which is not available from us.
6. Optional for removal of the protective cap. Ideal for sprinkler cabinets.
FREEDOM® RESIDENTIAL
CONCEALED PENDENT
SPRINKLER VK496 (K3.0)TECHNICAL DATA
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
Page 3 of 5
Form No. F_032218 19.03.21 Rev 19.1
TABLE 2: COVER PLATE ORDERING INFORMATION
Instructions: Using the cover plate base part number,
(1) add the suffix for the desired Finish
(2) add the suffix for the required Cover Plate Nominal Rating.
Cover Plate
Base Part
Number4
Size
Inch (mm)Style
1: Finishes Temperature Rating Matrix1,2
Description Suffix6
Cover Plate
Nominal Rating
(Required)
Sprinkler
Nominal Rating
Sprinkler Max.
Ambient Ceiling
Temperature2
Suffix
13504 2-3/4 (70)Round Polished Chrome F 135 °F (57 °C)155 °F (68 °C)100 °F (38 °C)A
13642 3-5/16 (84)Round Brushed Chrome F-/B 165 °F (73 °C)3 200 °F (93 °C)150 °F (65 °C)C
15394 3-5/16 (84)Square Bright Brass B
Corrosion Resistant Sprinkler Coating: ENT5
Example: 13504MA/W =
135 °F (57 °C) Temperature Rated 2-3/4” (70 mm) Diameter
Round Cover Plate with a Painted White finish.
Antique Brass B-/A
Brushed Brass B-/B
Brushed Copper E-/B
Painted White M-/W
Painted Ivory M-/I
Painted Black M-/B
Footnotes
1. The sprinkler temperature rating is stamped on the deflector.
2. Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having
Jurisdiction. Refer to specific installation standards.
3. Maximum ambient temperature for cover assembly is 100 °F (38 °C).
4. Part number shown is the base part number. For complete part number, refer to current our price list schedule.
5. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and
do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed
environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville
spring is exposed.
6. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above.
FREEDOM® RESIDENTIAL
CONCEALED PENDENT
SPRINKLER VK496 (K3.0)TECHNICAL DATA
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
Page 4 of 5
Form No. F_032218 19.03.21 Rev 19.1
APPROVAL CHART VK496, 3.0 K-Factor Residential Concealed Pendent Sprinkler
For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D
S p r i n k l e r B a s e
Part Number 1 SIN Thread Size Nominal K-Factor Maximum Water Working PressureInchesmmU.S.metric 2
22773 VK496 1/2 15 3.0 43.2 175 psi (12 bar)
Maximum
Coverage Area 5
W X L
Ft. X Ft.
(m X m)
All Temperatures Deflector
to Ceiling Installation Type
Listings and
Approvals3 Minimum Spacing
Ft.
(m)Flow
gpm (Lpm)
Pressure
PSI (bar)
4
12 X 12
(3.7 X 3.7)
8
(30.3)
7.1
(0.49)
Refer to
Figure 2
Concealed with Cover
Plate Assembly. See
Footnotes 6 & 7.
See Footnotes 3, 4, and 8 8
(2.4)
14 X 14
(4.3 X 4.3)
12
(45.4)
16
(1.1)
16 X 16
(4.9 X 4.9)
15
(56.8)
25
(1.72)
Footnotes
1. Part number shown is the base part number. For complete part number, refer to current our price schedule.
2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
3. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approv-
als. Refer also to Design Criteria.
4. Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union.
5. For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from
sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum “Flow” and “Pressure” used.
6. Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking
for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3.
7. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or
Painted Black 6.
8. C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT)
FREEDOM® RESIDENTIAL
CONCEALED PENDENT
SPRINKLER VK496 (K3.0)TECHNICAL DATA
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
Page 5 of 5
Form No. F_032218 19.03.21 Rev 19.1
DESIGN CRITERIA
(Also refer to the Approval Chart on page 3.)
UL Listing Requirements (C-UL-US-EU):
When using Viking Residential Concealed Pendent Sprinkler VK496 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover-age and minimum water supply requirements shown in the Approval Chart.
For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following:
• The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or
• Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13.
• Minimum distance between residential sprinklers: 8 ft. (2.4 m).
NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only.
IMPORTANT: Always refer to Bulletin Form No. F_080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be in-stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction.
Sprinkler and Adapter Assembly
• Protective cap removed
• Use wrench 14047W/B**
Step 1:
Carefully slide the wrench sideways around
the deflector and pins
Sprinkler Wrench
Part No. 14047W/B**
** A 1/2” ratchet is required (Not available from Viking)
2-1/4” (57 mm)
diameter opening
required in the
ceiling.
Step 2:
Carefully press the wrench upward and turn slightly to ensure engagement with
the sprinkler wrench flats.
Figure 1: Sprinkler Installation and Proper Wrench Usage
NEVER install the sprinkler by applying the installation
wrench across the frame arms. DO NOT overtighten.
Use only the designated sprinkler wrenches, Viking
Part Numbers 14047W/B** or 14031**. A leak tight seal
should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight.
Sprinkler
wrench flat
Sprinkler frame arms
FREEDOM® RESIDENTIAL
CONCEALED PENDENT
SPRINKLER VK496 (K3.0)TECHNICAL DATA
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
Page 6 of 5
Form No. F_032218 19.03.21 Rev 19.1
Figure 2: Sprinkler Dimensions and Cover Installation
1/2” (15 mm) NPT
2-1/4”(58 mm)2-9/16” (65 mm)Maximum 2-1/16” (52 mm)Minimum
2-3/4” (70 mm) or
3-5/16” (84 mm)NOTE: Upon sprinkler activation, the deflector descends
to approximately 13/16” (21 mm) below the sprinkler body.
Figure 3: Identification of Custom Paint for Concealed Covers
All custom color painted cover plates will have an
identifying label affixed to the inside of the cover that
indicates the custom color and will have a representative
sample (a paint dot) of the paint on the label.FACTORY APPLIE D C USTO
M
P
AI
NT COLORFigure 4: Square Cover Assembly 15394
3-5/16” (84 mm)
New page.
OFFICE OF THE FIRE MARSHAL – LA QUINTA
78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074
• www.rvcfire.org
October 28, 2021
J C Fire Protection
81705 De Oro Avenue
Indio, CA 92201
Re: Residential Fire Sprinkler Plan Review – PADRON RESIDENCE – LOT 61
FSS2021-0245 / 50990 CALLE PALOMA, LA QUINTA, CA 92253
The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County
Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions.
Permanently marked identification signs shall be attached to all control valves.
The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff:
(a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal
operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the
potential to contact CPVC piping once insulation is installed.
(b) Final inspection
The Fire Department approved plans and conditions letter must be at the job site.
Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for
inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131.
All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal
staff at (760)777-7074.
Kohl Hetrick - Fire Safety Specialist
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
RIVERSIDE COUNTY FIRE PROTECTION PLANNING
RECORD OF INSPECTIONS / PERMIT CARD
THIS CARD IS TO REMAIN ON SITE AT ALL TIMES.
INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE.
JOB
ADDRESS: 50990 CALLE PALOMA PERMIT#: FSS2021-0245 DATE
ISSUED: 10/28/2021
DESCRIPTION: PADRON RESIDENCE CONTRACTOR: J C FIRE PROTECTION
HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS
Thrust block pre-pour Door fan test
UG rough piping Abort test
UG hydro Mechanical shutdown
Flush Detector test
Final E F Deluge/pre-action
SPRINKLER U.G. Final E F
Thrust block pre-pour UST/AST TANK
UG rough piping Installation
UG hydro Removal
Flush Emergency shut off
Final E F Primary piping
FIRE SPRINKLER Secondary piping
Weld inspection Dispensers & shear valves
Overhead rough piping Final E F
Overhead hydro MISC. INSPECTIONS
UG flush / OK to connect Spray booths
Main drain/inspectors’ test Hood/duct extinguishing
High pile storage High pile rack storage
In-rack sprinklers H.P. vents/access/corridors
Hose racks Tract access/hydrant verification
Final E F Access & Address verification
HOOD EXTINGUISHING OTHER CONST. PERMIT
Detection system
Function test
Gas/electrical shut-off
Nozzle model/placement
Fire alarm connection
Final E F
SPRAY BOOTHS FIRE CODE PERMIT(S)
Installation
Air flow test
Mechanical interlock
Extinguishing system
Fire alarm connection
Final E F
FIRE ALARM KNOX SYSTEM
Rough-wire inspection Building Knox box
Function test Gate access Knox box/padlock
Duct detectors/velocity BUILDING INSPECTIONS
24 hr. battery test T/I final
Sprinkler monitoring Shell final
Final E F Final for occupancy
FINAL INSPECTION DATE: INSPECTORS SIGNATURE:
**WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE**
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
INSPECTION NOTES
1. Sway bracing and hangers will be inspected at the time of rough piping inspection.
2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler
Systems)
3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required.
4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test.
5. Contractor shall supply all testing equipment, access and operating instructions at time of test.
6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the
affected system to be covered or hidden.
POLICIES ON FIELD INSPECTIONS
A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when
scheduling inspections. For City of La Quinta inspections call: (760) 777-7131.
B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence
without approved plans.
C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required
to schedule the necessary inspections and be present on site for inspections.
D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not
on site or where previously noted corrections have not been completed.
E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into
the structure until clearance has been granted by the Fire Dept and Building Official.
F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance
has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official.
INSPECTION NOTES:
THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE
AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS.
THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180
DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE.
THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE
REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.