Loading...
FSS2021-0246ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT SOUTHWEST FIRE PROS 31410 RESERVE DR STE #2 THOUSAND PALMS CA 92276 (760)343-2233 maureen@southwestpl umbingandfire.com CONTRACTOR SOUTHWEST FIRE PROS 31410 RESERVE DR STE #2 THOUSAND PALMS CA 92276 (760)343-2233 maureen@southwestpl umbingandfire.com OWNER WASHINGTON 111 LTD 80618 DECLARATION AVE INDIO CA 92253 (760)343-2233 CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL AARON HICKSON 10/21/2021 10/21/2021 EMAIL SENT REQUESTING PLAN SHEETS TO BE COMBINED. AND INFORMED CONTRACTOR LICENSE IS UNDER SUSPENSION. CONDITIONS Description: NOTHING BUNDT CAKES - TI SPK Type: FIRE SPRINKLER (WEB)Subtype: Status: FINALED Applied: 10/21/2021 ECON Parcel No: 643020063 Site Address: 46660 WASHINGTON ST STE 10 LA QUINTA,CA 92253 Approved: 11/11/2021 KHET Subdivision: PM 32683-3 AMEND Block: Lot: 6 Issued: 11/12/2021 JOD Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 12/7/2021 KHET Valuation: $4,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Friday, March 03, 2023 9:19:29 AM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0246 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $167.00 $167.00 11/18/21 R68728 WEB9927 CREDIT SOUTHWEST FIRE PROS AMA FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS 101-0000-42420 0 $333.00 $333.00 11/12/21 WEB9864 633577083 35 CREDIT 1005165 ECON FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS PC 101-0000-42420 0 $167.00 $167.00 11/12/21 WEB9864 633577083 35 CREDIT 1005165 ECON Total Paid for FIRE FEES: $667.00 $667.00 10/28/2022: REFUND DUE TO DUPLICATE PAYMENT 101-0000-20330 0 $167.00 $167.00 11/19/21 R68729 WEB9938 CREDIT SOUTHWEST FIRE PROS AMA PAYMENT OVER COLLECTED 101-0000-20330 0 $167.00 $167.00 11/19/21 R68729 WEB9938 CREDIT SOUTHWEST FIRE PROS AMA Total Paid for PAYMENT OVER COLLECTED: $334.00 $334.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 11/12/21 WEB9864 633577083 35 CREDIT 1005165 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 11/12/21 WEB9864 633577083 35 CREDIT 1005165 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$1,017.00 $1,017.00 Printed: Friday, March 03, 2023 9:19:29 AM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0246 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/28/2022 CELESTE VILLANUEVA FSS2021-0246 REFUND Southwest Fire Pros 10.28.22.pdf FSS2021-0246 REFUND Southwest Fire Pros 10.28.22.pdf 0 DOC 10/21/2021 Etrakit Contractor PLANS Nothing Bundt Cakes Site Plan.pdf 1 DOC 10/21/2021 Etrakit Contractor PLANS Nothing Bundt Cakes Piping Plan.pdf 1 DOC 10/21/2021 Etrakit Contractor PLANS Nothing Bundt Cakes Piping Plan_1.pdf 1 DOC 10/21/2021 Etrakit Contractor DOCUMENT Dry VK.pdf 1 BOND INFORMATION OVERHEAD HYRO KHET 11/16/2021 11/16/2021 DISAPPROVE D EXPECTED PIPING CHANGES - RETEST OVERHEAD ROUGH PIPING KHET 11/16/2021 11/16/2021 DISAPPROVE D SEE ATTACHMENTS OVERHEAD HYRO KHET 11/22/2021 11/22/2021 APPROVED OVERHEAD ROUGH PIPING KHET 11/22/2021 11/22/2021 APPROVED FIRE FINAL**KHET 12/7/2021 12/7/2021 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH – ETRAKIT (1 DAY) PERMIT TECH BUCKET 10/21/2021 10/22/2021 10/21/2021 INCOMPLETE 1ST FIRE (2 WK)KOHL HETRICK 11/4/2021 11/18/2021 11/11/2021 APPROVED SEE ATTACHMENTS PARENT PROJECTS Printed: Friday, March 03, 2023 9:19:29 AM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0246 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/21/2021 Etrakit Contractor DOCUMENT VK302 Pend.pdf 1 DOC 10/21/2021 Etrakit Contractor PERMIT APPLICATION Permit Application.pdf 1 DOC 10/22/2021 Etrakit Contractor Nothing Bundt Cakes Plans.pdf 1 DOC 11/3/2021 Etrakit Contractor PLANS RE-UPLOAD Nothing Bundt Cakes Plans_1.pdf 1 DOC 11/11/2021 KOHL HETRICK FSS2021-0246 - APPROVED PLANS.pdf FSS2021-0246 - APPROVED PLANS.pdf 1 DOC 11/11/2021 KOHL HETRICK FSS2021-0246 - COA AND JOB CARD.pdf FSS2021-0246 - COA AND JOB CARD.pdf 0 DOC 11/16/2021 KOHL HETRICK FSS2021-0246 - 11-16- 2021 INSP NOTES.pdf FSS2021-0246 - 11-16- 2021 INSP NOTES.pdf 1 Printed: Friday, March 03, 2023 9:19:29 AM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0246 FSS2021-0246 COIL LOC. APPROX. COIL LOC. APPROX. COIL LOC. APPROX. EMX EMX S2 S2 S2 S2 S1 BB B BB B B B BB NL B EMR EMR S3 EMREMR B NL EM A AA A AA AA A A A A A A NL A NL EM RING HANGER (TOLCO FIG. 200) 3/8" ALL-THREAD ROD PIPE WOOD BEAM OR RAFTER WOOD SAMMY SUPERSCREW (Model GST20) 2x_ BLOCKING (TO BE SAME SIZE AS RAFTER) NAILED TO RAFTERS w/ (2) 10d NAILS EACH SIDE OF BLOCK. WOOD BEAM OR RAFTER WOOD BEAM OR RAFTER RING HANGER (TOLCO FIG. 200) 3/8" ALL-THREAD ROD PIPE WOOD SAMMY SIDEWINDER (Model SWG20) RING HANGER (TOLCO FIG. 200) 3/8" ALL-THREAD ROD PIPE WOOD BEAM OR RAFTER WOOD SAMMY SIDEWINDER (Model SWG20) 2x_ BLOCKING (TO BE SAME SIZE AS RAFTER) NAILED TO RAFTERS w/ (2) 10d NAILS EACH SIDE OF BLOCK. WOOD BEAM OR RAFTER WOOD BEAM OR RAFTER RING HANGER (TOLCO FIG. 200) 3/8" ALL-THREAD ROD PIPE WOOD SAMMY SUPERSCREW (Model GST20) TOLCO TOLCO UPRIGHT SPRINKLER 1" SPRIG 1" NIPPLE BRANCHLINE PIPING 1" PLUG FOR FURTURE TENANT IMPROVEMENTS 1" TEE 1" x 1/2" REDUCER ROOSTER-TAIL / SPRIG-UP DETAIL NOT TO SCALE EXISTING 3" Riser EXISTING 3" Main EXISTING 1-1/2" BRANCH LINESEXISTING 1-1/2" BRANCH LINESEXISTING 1-1/2" BRANCH LINESEXISTING 1-1/2" BRANCH LINESEXISTING 1-1/2" BRANCH LINESE E E E E E E E E E E E E E E E E E E E N N N N NNNN N N N N N N NN N 1" 0' -8" 1" 3' -10" 1" 0' -8" 1" 4' -8" 1" 1' -10" 1" 1' -10" 1" 3' -10" 1" 3' -10" 1" 3' -10" 1" 2' -10" 1" 7' -7" 1" 1' -3" WALK-IN REFRIG 9'-0" WALK-IN CHILLER 9'-0" DRY STORAGE 12'-0" BAKING/FROSTING AREA 12'-0" OVEN AREA 12'-0" DISH WASH 12'-0" CRAFT AREA 12'-0" LOBBY SALES 12'-0" REST ROOM 9'-0" N 22' - 6"1"4' -0"1" 5' -9" 1" 8' -6" 1" 1' -6" 1" 7' -7" 1" 1' -6" 1" 1' -6" 1" 7' -7" southwestfirepros.com Scale Project number Date Drawn by Checked by Southwest Fire Pros31410 Reserve Drive Suite # 2Thousand Palms, Ca 92276Phone (760) 343-2233Fax (760( 343-2210e-mail southwestfirepros.comAs indicated 10/20/2021 3:15:06 PMFP-2 Piping Plan 2021-242 Nothing Bundt Cakes 10-21-21 JA CCOwner Enter address hereNo. Description Date NOTHING BUNDT CAKES46660 Washington StreetSuite 10La Quinta, Ca.1/4" = 1'-0"1 Piping Plan Sprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 3 Viking 1/2 Ordinary Pendent Temperature - 200 Finish - C Special Response Model - Micromatic SIN - VK180 K Factor - 5.6 VK180 5.6 1/2" 200 °F 17 Viking 1/2 Ordinary Temperature - 155 Finish - B Quick Response Model - Mirage SIN - VK302 K Factor - 5.6 VK302 5.6 1/2" 155 °F 20 Viking 1/2 Ordinary Upright Temperature - 175 Finish - B Special Response Model - Micromatic SIN - VK138 K Factor - 5.6 VK138 5.6 1/2" 175 °F : 40 Total No. of Sprinklers: 40 NEW NEW EXISTING COIL LOC. APPROX. COIL LOC. APPROX. COIL LOC. APPROX. EMX EMX S2 S2 S2 S2 S1 BB B BB B B B BB NL B S1 S1 EMR EMR S3S3 EMREMR B NL EM A AA A AA AA A A A A A A NL A NL EM EXISTING 3" Riser WALK-IN REFRIG 9'-0" WALK-IN CHILLER 9'-0" DRY STORAGE 12'-0" BAKING/FROSTING AREA 12'-0" OVEN AREA 12'-0" DISH WASH 12'-0" CRAFT AREA 12'-0" LOBBY SALES 12'-0" REST ROOM 9'-0" SOFFIT 10'-0" SOFFIT 10'-0" 6' - 0"1' - 10" 5' - 8" 11' - 3"5' - 8"5' - 2"5' - 2"5' - 2"5' - 2"3' - 9"3' - 9" 2' - 7"6' - 0" 4' - 0"6' - 0"2' - 7"8' - 0"12' - 0"7' - 7"3' - 5"3' - 7"3' - 11"3' - 1"7' - 0"10' - 0"2' - 8"1' - 7"10' - 0"4' - 9"5' - 0"8' - 0"4' - 6"4' - 8"10' - 0"8' - 0"4' - 9"5' - 0"8' - 0"4' - 6" southwestfirepros.com Scale Project number Date Drawn by Checked by Southwest Fire Pros31410 Reserve Drive Suite # 2Thousand Palms, Ca 92276Phone (760) 343-2233Fax (760( 343-2210e-mail southwestfirepros.com1/4" = 1'-0"10/20/2021 3:16:29 PMFP-3 RCP 2021-242 Nothing Bundt Cakes 10-21-21 Author CheckerOwner Enter address hereNo. Description Date NOTHING BUNDT CAKES46660 Washington StreetSuite 10La Quinta, Ca.1/4" = 1'-0"1 RCP Sprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 3 Viking 1/2 Ordinary Pendent Temperature - 200 Finish - C Special Response Model - Micromatic SIN - VK180 K Factor - 5.6 VK180 5.6 1/2" 200 °F 17 Viking 1/2 Ordinary Temperature - 155 Finish - B Quick Response Model - Mirage SIN - VK302 K Factor - 5.6 VK302 5.6 1/2" 155 °F 20 Viking 1/2 Ordinary Upright Temperature - 175 Finish - B Special Response Model - Micromatic SIN - VK138 K Factor - 5.6 VK138 5.6 1/2" 175 °F : 40 Total No. of Sprinklers: 40 EXISTING NEW NEW COIL LOC. APPROX. COIL LOC. APPROX. COIL LOC. APPROX. EMX EMX S2 S2 S2 S2 S1 BB B BB B B B BB NL B EMR EMR S3 EMREMR B NL EM A AA A AA AA A A A A A A NL A NL EM RING HANGER (TOLCO FIG. 200) 3/8" ALL-THREAD ROD PIPE WOOD BEAM OR RAFTER WOOD SAMMY SUPERSCREW (Model GST20) 2x_ BLOCKING (TO BE SAME SIZE AS RAFTER) NAILED TO RAFTERS w/ (2) 10d NAILS EACH SIDE OF BLOCK. WOOD BEAM OR RAFTER WOOD BEAM OR RAFTER RING HANGER (TOLCO FIG. 200) 3/8" ALL-THREAD ROD PIPE WOOD SAMMY SIDEWINDER (Model SWG20) RING HANGER (TOLCO FIG. 200) 3/8" ALL-THREAD ROD PIPE WOOD BEAM OR RAFTER WOOD SAMMY SIDEWINDER (Model SWG20) 2x_ BLOCKING (TO BE SAME SIZE AS RAFTER) NAILED TO RAFTERS w/ (2) 10d NAILS EACH SIDE OF BLOCK. WOOD BEAM OR RAFTER WOOD BEAM OR RAFTER RING HANGER (TOLCO FIG. 200) 3/8" ALL-THREAD ROD PIPE WOOD SAMMY SUPERSCREW (Model GST20) TOLCO TOLCO UPRIGHT SPRINKLER 1" SPRIG 1" NIPPLE BRANCHLINE PIPING 1" PLUG FOR FURTURE TENANT IMPROVEMENTS 1" TEE 1" x 1/2" REDUCER ROOSTER-TAIL / SPRIG-UP DETAIL NOT TO SCALE EXISTING 3" Riser EXISTING 3" Main EXISTING 1-1/2" BRANCH LINESEXISTING 1-1/2" BRANCH LINESEXISTING 1-1/2" BRANCH LINESEXISTING 1-1/2" BRANCH LINESEXISTING 1-1/2" BRANCH LINESE E E E E E E E E E E E E E E E E E E E N N N N NNNN N N N N N N NN N 1" 0' -8" 1" 3' -10" 1" 0' -8" 1" 4' -8" 1" 1' -10" 1" 1' -10" 1" 3' -10" 1" 3' -10" 1" 3' -10" 1" 2' -10" 1" 7' -7" 1" 1' -3" WALK-IN REFRIG 9'-0" WALK-IN CHILLER 9'-0" DRY STORAGE 12'-0" BAKING/FROSTING AREA 12'-0" OVEN AREA 12'-0" DISH WASH 12'-0" CRAFT AREA 12'-0" LOBBY SALES 12'-0" REST ROOM 9'-0" N 22' - 6"1"4' -0"1" 5' -9" 1" 8' -6" 1" 1' -6" 1" 7' -7" 1" 1' -6" 1" 1' -6" 1" 7' -7" southwestfirepros.com Scale Project number Date Drawn by Checked by Southwest Fire Pros31410 Reserve Drive Suite # 2Thousand Palms, Ca 92276Phone (760) 343-2233Fax (760( 343-2210e-mail southwestfirepros.comAs indicated 10/20/2021 3:15:06 PMFP-2 Piping Plan 2021-242 Nothing Bundt Cakes 10-21-21 JA CCOwner Enter address hereNo. Description Date NOTHING BUNDT CAKES46660 Washington StreetSuite 10La Quinta, Ca.1/4" = 1'-0"1 Piping Plan Sprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 3 Viking 1/2 Ordinary Pendent Temperature - 200 Finish - C Special Response Model - Micromatic SIN - VK180 K Factor - 5.6 VK180 5.6 1/2" 200 °F 17 Viking 1/2 Ordinary Temperature - 155 Finish - B Quick Response Model - Mirage SIN - VK302 K Factor - 5.6 VK302 5.6 1/2" 155 °F 20 Viking 1/2 Ordinary Upright Temperature - 175 Finish - B Special Response Model - Micromatic SIN - VK138 K Factor - 5.6 VK138 5.6 1/2" 175 °F : 40 Total No. of Sprinklers: 40 NEW NEW EXISTING MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA Form No. F_033314 19.10.14 Rev 19.2 Page 1 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small ther- mosensitive glass bulb spray sprinkler available with various finishes and tempera- ture ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 LPCB Approved: Certificate 096e/06 CE Certified: Standard EN 12259-1, certificate of constancy of performance 0832-CPR-S0021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2” NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4” (58 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G Replaces Form No. F_033314 Rev 19.1 (Added ENT; updated FM language.) MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA Form No. F_033314 19.10.14 Rev 19.2 Page 2 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: A. Standard Wrench: Part No. 21475M/B. B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A ½” ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1” diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast® Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 21475M/B Protective Sprinkler Cap Wrench Flat MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA Form No. F_033314 19.10.14 Rev 19.2 Page 3 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 135 °F (57 °C)100 °F (38 °C)Orange Ordinary 155 °F (68 °C)100 °F (38 °C)Red Intermediate 175 °F (79 °C)150 °F (65 °C)Yellow Intermediate 200 °F (93 °C)150 °F (65 °C)Green High 286 °F (141 °C)225 °F (107 °C)Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Sprinkler wrench 13655W/B** for recessed pendent sprinklers ** A 1/2” ratchet is required (not available from Viking) MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA Form No. F_033314 19.10.14 Rev 19.2 Page 4 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 1 (UL) The Viking Microfast® Quick Response Pendent Sprinkler VK302 Maximum 175 PSI (12 Bar) WWP Base Part Number1 SIN Sprinkler Style Thread Size Nominal K-Factor Overall Length Listings and Approvals3 (Refer also to Design Criteria.) NPT BSP U.S.metric2 Inches mm cULus4 VdS LPCB 7 8 12979 VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X A1 A1Z, B1Y D1Z, C1Y D1 -- 19780 VK302 Pendent 1/2” --5.6 80.6 2-1/4 58 ----------D3 21354 VK302 Pendent --15 mm 5.6 80.6 2-1/4 58 ----------D3 NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 06662B VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X ---------- 18021 VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1X, B1Y A1 A1X, B1Y D1X, C1Y7 D1 -- Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C) B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) C - 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) D - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C) Approved Finishes 1 - Brass, Chrome, White Polyester5,6, Black Polyes- ter5,6 2 - ENT5 3 - Chrome Approved Escutcheons X - Standard surface-mounted escutcheon or the Viking Micromatic® Model E-1 Recessed Escutcheon Y - Standard surface-mounted escutcheon or recessed with the Viking Micromatic® Model E-1, E-2, or E-3 Recessed Escutcheon Z - Standard surface-mounted escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. 7 CE Certified, Standard EN 12259-1, EC-certificate of constancy of performance 0832-CPR-S0021. 8 MED Certified, Standard EN 12259-1, EC-0832-MED-1003. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA Form No. F_033314 19.10.14 Rev 19.2 Page 5 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) The Viking Microfast® Quick Response Pendent Sprinkler VK302 Maximum 175 PSI (12 Bar) WWP Base Part Number1 SIN Sprinkler Style Thread Size Nominal K-Factor Overall Length FM Approvals3 (Refer also to Design Criteria.)NPT BSP U.S.metric2 Inches mm 12979 VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 06662B VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C) B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C) D - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) Approved Finishes 1 - Brass, Chrome, White Polyester4, and Black Polyester4 2 - ENT5 Approved Escutcheons X - Standard surface-mounted escutcheon or the Viking Micromatic® Model E-1 Recessed Escutcheon Y - Standard surface-mounted escutcheon or recessed with the Viking Micromatic® Model E-1 or E-2 Recessed Escutcheon Z - Standard surface-mounted escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Other approvals may be in process. 4 Other colors are available on request with the same Approvals as the standard colors. 5 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA Form No. F_033314 19.10.14 Rev 19.2 Page 6 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Figure 3: Sprinkler Dimensions with a Standard Escutcheon 1/2” (15 mm) NPT 2-1/4” (57 mm)1-3/4” (45 mm) Installed with a standard 1/8” surface-mounted escutcheon Ceiling Opening Size: 2-5/16” (59 mm) minimum 2-1/2” (64 mm) maximum 1-3/4” (45 mm)Max. 2-1/8” (54 mm) 1-1/8” (29 mm)Min. 2”” (51 mm)Max. 1-1/8” (29 mm)Min. 2-1/8” (54 mm) Ceiling Opening Size: 2-5/16” (59 mm) minimum 2-1/2” (64 mm) maximum Installed with a Model E-1 Recessed Escutcheon Installed with a Model E-2 Thread-on Recessed Escutcheon Replaces Form No. F_033314 Rev 19.1 (Added ENT; updated FM language.) QUICK RESPONSE DRY PENDENT SPRINKLERSTECHNICAL DATA Form No. F_031793 19.10.14 Rev 19.2 Page 1 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION Viking Quick Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry sys- tems and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Quick Response Dry Pendent Sprinklers are available in various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global has no approval classification for Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2013 and 2015 NYC Approved: MEA 89-92-E Volume 15 Refer to Approval Chart 1 and Design Criteria on page 105d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 105e for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1” NPT or 25 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric*) for all listed and approved lengths. * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Covered by the following U.S. Patents: 8,636,075 and 10,220,231 Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Pip Cap: Brass UNS-C31400 or UNS-C31600 Pip Cap Adapter: Brass UNS-C36000 Orifice: Copper UNS-C22000 or UNS-C11000 Tube: ERW Hydraulic Steel Tube Support (Internal): Stainless Steel UNS-S30400 Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Barrel End and Threads: QM Brass Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 ENT Coated Adjustable and Recessed Escutcheons: Stainless Steel UNS-S30400 Ordering Information: (Also refer to the current Viking price list.) Replaces Form F_031793 Rev. 19.1 (Added ENT; updated FM language.) QUICK RESPONSE DRY PENDENT SPRINKLERSTECHNICAL DATA Form No. F_031793 19.10.14 Rev 19.2 Page 2 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Order Quick Response Dry Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating, and then the suffix for the length (“A” dimension) to sprinkler base part number. Order in a specific length noted as the “A” dimension. The “A” dimension is the distance from the face of the fitting (tee) to the desired finished surface of the ceiling. These sprinklers are listed and approved in lengths from 1-1/2” to 45-1/2” (38.1 mm to 1,156 mm) for the adjustable standard style, 3” to 47” (76.2 mm to 1,194 mm) for the plain barrel style, and 3-1/4” to 47-1/2” (82.5 mm to 1,207 mm) for the adjustable recessed style. Lengths exceeding the standard lengths are available, with no approvals, on a “made-to-order” basis: Recessed Dry Pendent up to 65-1/2” (1,664 mm). Adjustable Standard Dry Pendent up to 63-1/2” (1,613 mm). Plain Barrel Dry Pendent up to 65” (1,651 mm). Contact the manufacturer for more information. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G For example, sprinkler VK176 with a Chrome finish and a 155 °F (68 °C) temperature rating, and “A” length of 10” = Part No. 08383UFB10. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the “Sprinkler Accessories” section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 07297W/B (available since 1991) B. Wrench for recessed sprinklers: Part No. 07565W/B** (available since 1991) **A ½” ratchet is required (not available from Viking). Sprinkler Guard: Chrome, with no listings or approvals, for installation on dry pendent sprinklers made after May 1994 only (Part No. 08954). Replacement Escutcheons: A. Adjustable Standard Dry Escutcheon: Base Part No. 07741 B. Recessed Dry Escutcheon Cup: Base Part No. 05459A 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the internal parts to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS & MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Quick Response Dry Pendent Sprink- ler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 07297W/B Figure 2: Wrench 07565W/B for Adjustable Recessed Dry Pendent Sprinklers QUICK RESPONSE DRY PENDENT SPRINKLERSTECHNICAL DATA Form No. F_031793 19.10.14 Rev 19.2 Page 3 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 155 °F (68 °C)100 °F (38 °C)Red Intermediate 175 °F (79 °C)150 °F (65 °C)Yellow Intermediate 200 °F (93 °C)150 °F (65 °C)Green High 286 °F (141 °C)225 °F (107 °C)Blue Sprinkler Finishes: Brass, Chrome, White Polyester, and ENT Corrosion-Resistant Coating3,4: White Polyester and ENT in all temperature ratings Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Note: These coatings are NOT cor- rosion proof. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environ- ment. Polyester and ENT coatings are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. 4 When installed in some corrosive environments, the Polyester finish may change color. This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. Figure 3: Adjustable Standard Dry Pendent Sprinkler QUICK RESPONSE DRY PENDENT SPRINKLERSTECHNICAL DATA Form No. F_031793 19.10.14 Rev 19.2 Page 4 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 1 (UL) Quick Response Dry Pendent Sprinklers Maximum 175 PSI (12 bar) WWP Sprinkler Base Part No.1 SIN Style Thread Size Nominal K-Factor2 Order Length Increment Listings and Approvals4 (Refer also to Design Criteria below.) NPT BSP U.S.metric3 Inches mm cULus5 NYC6 VdS LPCB 08383U VK176 Adjustable Standard 1”--5.6 80.6 1/2”12.7 A1, A5 A1 -------- 16457U --25 mm --80.6 1/2”12.7 A1, A5 ---------- 08385U VK180 Adjustable Recessed 1”--5.6 80.6 1/4”6.35 B2, B6 B2 -------- 16453U --25 mm --80.6 1/4”6.35 B2, B6 ---------- 08387U VK172 Plain Barrel 1”--5.6 80.6 1/2”12.7 A3 A4 -------- 16455U --25 mm --80.6 1/2”12.7 A3 ---------- Approved Temperature Ratings A - 155 °F (68 °C), 175 °F (79°C), 200 °F (93 °C), and 286 °F (141 °C) B - 155 °F (68 °C), 175 °F (79°C), and 200 °F (93 °C) Approved Finishes and “A” Dimensions 1 - Chrome or White Polyester7 sprinkler with a Chrome or White Polyester Sleeve and Escutcheon with “A” dimensions 1-1/2” to 45-1/2” (38.1 mm to 1,156 mm) 2 - Chrome or White Polyester7 with “A” dimensions 3-1/4” to 47-1/2” (82.5 mm to 1,207 mm) 3 - Chrome, Brass, White Polyester7, or ENT 7 with “A” dimensions 3” to 47” (76.2 mm to 1,194 mm) 4 - Chrome or Brass with “A” dimensions 3” to 47” (76.2 mm to 1,194 mm) 5 - ENT7 sprinkler with an ENT7 Sleeve and Escutcheon with “A” dimensions 1-1/2” to 45-1/2” (38.1 mm to 1,156 mm) 6 - ENT7 with “A” dimensions 3-1/4” to 47-1/2” (82.5 mm to 1,207 mm) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths (“A” Dimensions indicated above). 3 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 4 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5 Listed by Underwriter’s Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 15. 7 cULus Listed as corrosion resistant. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-Bl tees. When selecting other CPVC fittings, contact Viking Technical Services. cULus Listing Requirements: Standard Dry Pendent Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. QUICK RESPONSE DRY PENDENT SPRINKLERSTECHNICAL DATA Form No. F_031793 19.10.14 Rev 19.2 Page 5 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.comApproval Chart 2 (FM) Quick Response Dry Pendent Sprinklers Maximum 175 PSI (12 bar) WWP Sprinkler Base Part No.1 SIN Style Thread Size Nominal K-Factor2 Order Length Increment FM Approvals4 (Refer also to Design Criteria below.)NPT BSP U.S.metric3 Inches mm 08383U VK176 Adjustable Standard 1”--5.6 80.6 1/2”12.7 A1 16457U --25 mm --80.6 1/2”12.7 A1 08385U VK180 Adjustable Recessed 1”--5.6 80.6 1/4”6.35 B2 16453U --25 mm --80.6 1/4”6.35 B2 08387U VK172 Plain Barrel 1”--5.6 80.6 1/2”12.7 A3 16455U --25 mm --80.6 1/2”12.7 A3 Approved Temperature Ratings A - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141 °C) B - 155 °F (68 °C), 175 °F (79°C), and 200 °F (93 °C) Approved Finishes and “A” Dimensions 1 - Brass, Chrome, White Polyester, or ENT5 sprinkler with a Brass, Chrome, White Polyester, or ENT5 Sleeve and Escutcheon with “A” dimensions 1-1/2” to 45-1/2” (38.1 mm to 1,156 mm) 2 - Brass, Chrome, White Polyester, or ENT5 with “A” dimensions 3-1/4” to 47-1/2” (82.5 mm to 1,207 mm) 3 - Brass, Chrome, White Polyester, or ENT5 with “A” dimensions 3” to 47” (76.2 mm to 1,194 mm) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths (“A” Dimensions indicated above). 3 Metric K-Factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 4 This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any ad-ditional approvals. 5 FM approved as corrosion resistant. Figure 4: Adjustable Recessed Dry Pendent Sprinkler Figure 5: Plain Barrel Dry Pendent Sprinkler DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-Bl tees. When selecting other CPVC fittings, contact Viking Technical Services. FM Approval Requirements: The Dry Pendent Sprinklers in the Approval Chart above are FM Approved as quick response Non-storage standard spray sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (includ-ing 2-0) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. QUICK RESPONSE DRY PENDENT SPRINKLERSTECHNICAL DATA Form No. F_031793 19.10.14 Rev 19.2 Page 6 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Figure 6: Dry Pendent Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry Pendent Sprinkler is Shown) Figure 7: Dry Sprinkler Seal (Adjustable Standard Dry Pendent Sprinkler is Shown) Replaces Form F_031793 Rev. 19.1 (Added ENT; updated FM language.) OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org November 11, 2021 Southwest Fire Pros 31410 Reserve Dr #2 Thousand Palms, CA 92276 Re: TI Fire Sprinkler Plan Review – NOTHING BUNDT CAKES FSS2021-0246 / 46660 WASHINGTON ST #10, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. The following inspections/tests are required to be witnessed by the Office of the Fire Marshal staff: 1) Overhead Rough: All installed/relocated piping must be visible. 2) Final inspection: All trim is in place, 5-Year certification is current. New/added heads shall be included in the spare head box compliment. *Water-flow signal test may be performed during the Final Inspection. All persons performing work on the automatic fire sprinkler system shall be Certified Sprinkler Fitters or Registered with the State Fire Marshal for Apprentice or Trainee classification. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 46660 WASHINGTON ST #10 PERMIT#: FSS2021-0246 DATE ISSUED: 11/11/2021 DESCRIPTION: NOTHING BUNDT CAKES CONTRACTOR: SOUTHWEST FIRE PROS HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. Check Mailed on 10.28.22 CV