Loading...
FSS2021-0254ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE JOSE DELGADO 1/13/2023 1/13/2023 CONTRACTOR REQUESTED FINAL INSPECTION. PERMIT EXPIRED AS OF 11/15/22 (6 MOS FROM DATE OF LAST APPROVED INSPECTION). ADDED EXTENSION FEE OF $88 AND EXTENDED PERMIT TO 1/17/23 SO CONTRACTOR CAN PAY FEE VIA ETRAKIT. WILL ALSO REQUIRE AN EXTENSION REQUEST LETTER FROM CONTRACTOR. OK TO EXTEND PER KOHL. FEES HAVE BEEN PAID AND CONTRACTOR PROVIDED EXTENSION REQUEST. EXTENDING PERMIT FOR ANOTHER 6 MONTHS. CONDITIONS Description: DUCEY / FIRE SPRINKLERS / BRES2021-0300 Type: FIRE SPRINKLER (WEB)Subtype: Status: FINALED Applied: 11/9/2021 ECON Parcel No: 770173012 Site Address: 78620 AVENIDA NUESTRA LA QUINTA,CA 92253 Approved: 12/6/2021 KHET Subdivision: DESERT CLUB TR UNIT 5 Block: Lot: 172 Issued: 12/8/2021 AHI Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 1/18/2023 KHET Valuation: $5,800.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Friday, March 03, 2023 9:56:28 AM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0254 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT SOUTHWEST FIRE PROS 31410 RESERVE DR STE #2 THOUSAND PALMS CA 92276 (760)343-2233 maureen@swfirepros.c om CONTRACTOR SOUTHWEST FIRE PROS 31410 RESERVE DR STE #2 THOUSAND PALMS CA 92276 (760)343-2233 maureen@swfirepros.c om OWNER TROY HORTON 17001 LIVORNO DR PACIFIC PALISADES CA 90272 (760)343-2233 FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $167.00 $167.00 5/20/22 WEB11820 637261536 70 CREDIT 1005165 ECON FIRE PERMIT EXTENSION (ADMIN PROCESSING) 101-0000-42420 0 $88.00 $88.00 1/13/23 WEB14057 787625236 CREDIT 1005165 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $167.00 $167.00 12/8/21 WEB10091 634101506 50 CREDIT 1005165 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $250.00 $250.00 12/8/21 WEB10091 634101506 50 CREDIT 1005165 ECON Total Paid for FIRE FEES: $672.00 $672.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 12/8/21 WEB10091 634101506 50 CREDIT 1005165 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 12/8/21 WEB10091 634101506 50 CREDIT 1005165 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$688.00 $688.00 Printed: Friday, March 03, 2023 9:56:28 AM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0254 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/9/2021 Etrakit Contractor 1ST SUBMITTAL PLANS Avenida Nuestra Plans.pdf 1 DOC 11/9/2021 Etrakit Contractor 1ST SUBMITTAL HYDRAULIC CALCULATIONS Document Calc-2.pdf 1 BOND INFORMATION INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 5/19/2022 5/19/2022 DISAPPROVE D Coverage issues and insulation of pipe is needed. Reinspection required. Fees apply. *Separately, prior to final inspection - revised plans and calcs are required for review and approval to address riser location change and WM size of 3/4". OVERHEAD HYRO KHET 5/19/2022 5/19/2022 APPROVED OVERHEAD ROUGH PIPING KHET 5/23/2022 5/23/2022 APPROVED FIRE FINAL**KHET 1/18/2023 1/18/2023 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE - ETRAKIT (2 WK) KOHL HETRICK 11/9/2021 11/24/2021 12/6/2021 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH – ETRAKIT (1 DAY) PERMIT TECH BUCKET 11/9/2021 11/10/2021 11/9/2021 COMPLETE PARENT PROJECTS Printed: Friday, March 03, 2023 9:56:28 AM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0254 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/9/2021 Etrakit Contractor 1ST SUBMITTAL VIKING VK-494 4.9 k Res 155 deg.pdf 1 DOC 11/9/2021 Etrakit Contractor 1ST SUBMITTAL DOCUMENT 1ST SUBMITTAL Water Flow System Analysis.pdf 1 DOC 11/9/2021 Etrakit Contractor 1ST SUBMITTAL PERMIT APPLICATION Permit Application.pdf 1 DOC 1/13/2023 Etrakit Contractor Permit Extension Request 1.13.2023.pdf 1 DOC 12/6/2021 KOHL HETRICK FSS2021-0254 - APPROVED PLANS AND CALCS.pdf FSS2021-0254 - APPROVED PLANS AND CALCS.pdf 1 DOC 12/6/2021 KOHL HETRICK FSS2021-0254 - COA AND JOB CARD.pdf FSS2021-0254 - COA AND JOB CARD.pdf 1 DOC 5/19/2022 KOHL HETRICK FSS2021-0254 - 5-19- 2022 INSP NOTES.pdf FSS2021-0254 - 5-19- 2022 INSP NOTES.pdf 1 Printed: Friday, March 03, 2023 9:56:28 AM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0254 78620FSS2021-0254 2x6 STUD WALL @ 16"O.C.2x6 STUD WALL @ 16"O.C.2x4 STUD WALL @ 16"O.C.Pant r y Cabi net Lin e n C a bin et Tall Cabinets U n d e rc o u nterWin e C o ole r Cabinet 42" High Wall30" Oven&Microwave36" CooktopFIREPLACE TV PH 10" ∅Solatube10" ∅Solatube10" ∅Solatube10" ∅SolatubeCAST IRONBATHVINTAGEK-700 BRASSFAUCETSPINSTRIPEK-T13134-3B BRASSFAUCETSPINSTRIPEK-T13134-3B BRASSFAUCETSPINSTRIPEK-T13134-3B BRASSFAUCETSPINSTRIPEK-T13134-3B 3'-117/8"7'-43/16"4'-103/4"3'3'4'-103/4" 5'3'INSPECTOR TEST DETAIL 5' 1" Ball Valve Access Panel (By Others) Exterior Wall of Building Inspector Test to Terminate in a Smooth Bore Corrosion Resistant Orfice With a Flow Equivalent to One Sprinkler NOTE: Access Panel Shall have sign Indicating Inspector Test CPVC HANGERS NO SCALE TOLCO FIG. 24 DOUBLE-FASTENER SIDE-MOUNT HANGER (OR EQUAL) SELF-DRILLING HEX HEAD SCREW TOLCO FIG. 23 DOUBLE-FASTENER STRAP TYPE HANGER (OR EQUAL) TOLCO FIG. 28M OFFSET HANGER (OR EQUAL) TOLCO FIG. 22 SINGLE-FASTENER STRAP-TYPE HANGER (OR EQUAL) TOLCO FIG. 28 DOUBLE-FASTENER STAND-OFF HANGER (OR EQUAL) TOLCO FIG. 29 DOUBLE-FASTENER DOUBLE OFFSET HANGER (OR EQUAL) CPVC HANGER SPACING PIPE SIZE 11/4" 1" MAXIMUM SUPPORT SPACING 6'-6" 6'-0" 2"8'-0" 11/2"7'-0" www.cadm ando.co.uk These blocks were brought to you by CADBlocksFree.com.For all of your 2D & 3D CAD outsource requirements visit us: C A D M A N D O www.cadblocksfree.com COVER WITH HINGED LID FINISHED GRADE DISC-TYPE WATER METER PLUG VALVE(TYP.)UNION(TYP.)42" High Wall10" ∅SolatubeCAST IRONBATHVINTAGEK-7007'-43/16"Water Supply Information Static Pressure: Residual Pressure: Residual Flow: Additional Hose Flow: 97.70 psi 89.20 psi 1350 GPM 0 GPM Calc-1 INSPECTORS TEST 1-1/4: PVC UG BY OTHERS1" RISERNOTIFICATION DEVICE BY OTHERSGARAGE 10'-0" BEDROOM 3 10'-0" BEDROOM 2 10'-0" KITCHEN 10'-0" NOOK 10'-0" LIVING 10'-0" DINING 10'-0" MASTER BEDROOM 10'-0" MASTER BATH 10'-0" HIS W.I.C. 10'-0" HER W.I.C. 10'-0" LAUNDRY 10'-0" PANTRY 10'-0" W.I.C. >24sf W.I.C. >24sf BATH > 55 sf BATH > 55 sf BATH > 55 sf 1" 7' -6" 1" 3' -10" 1" 5' -10" 1" 10' -5" 1" 14' -2" 1" 2' -11"1"7' -5"1"7' -0"1"7' -0"1" 17' -2" 1" 7' -0"1"3' -6"1"4' -6"1"4' -9"1" 21' -6"1"3' -3"1" 6' -8" 1" 4' -8"1"8' -1"1"5' -4"1" 2' -1" 1" 7' -4" 1" 7' -4" 1" 7' -4"1"14' -4"1" 4' -8"1"14' -0"1" 4' -8" 1" 3' -0" 1" 5' -9" 1" 0' -6" 1" 12' -0" 1" 12' -0" 1" 0' -8"1"4' -9"1" 3' -4" 1" 4' -3" 1" 5' -10"1"12' -0"1" 2' -2"1"14' -5"1" 7' -0" 1" 3' -6" 1" 0' -7" 1" 5' -2" 1" 7' -0" 1" 0' -11"1"4' -1"1" 2' -0" 1" 5' -0" 1" 2' -10" 1" 6' -7" 1" 0' -5"1"3' -2"1" 6' -2" Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-2 R-3 2 Gpm/SqFt 512 Max SqFt 31.0023 GPM 37.2915 Psi 5 GPM 0 GPM 8 6 12 3 4 7 BOR TOR DOM 1 1/4" x 4' -0"1" x 8' -0"1" x 2' -0"1"7' -9"1" 2' -10" Fire Sprinkler Riser Detail TOR BOR Domestic Supply Check Flow Control 1" CPVC Flow Switch Note Wiring by Others 300psi Gage Sprinkler Box with Wrench & two Sprinkler Heads Each Type 1/2" Drain to Outside1"1"1" Notification Device Wired by Others not to scale Module Must Connect to the Multi Station Smoke Alarm System and the Fire Sprinkler Flow Switch ( all wiring by others ) 1" RISER NOTE: 5psi shown as friction loss at 1" Water Meter MASTER BATH 10'-0" HIS W.I.C. 10'-0" HER W.I.C. 10'-0" 1" 5' -10"1"12' -0"1" 2' -2" Supply Point WM 5 BOR TOR DOM 1 1/4"19' -0"1 1/4" 17' -9" 1 1/4" 1' -6"1 1/4"0' -10"1 1/4" x 4' -0"1" x 8' -0"1" 1' -0"1" x 2' -0"1"7' -9"1" 2' -10" southwestfirepros.com Scale Project number Date Drawn by Checked bySouthwest Fire Pros31410 Reserve Drive Suite # 2Thousand Palms, Ca 92276Phone (760) 343-2233Fax (760( 343-2210e-mail southwestfirepros.comLic. No. C-16 1005165As indicated 11/8/2021 10:15:19 AMFP-2 Piping Plan 2021-215-R Nuestra 11-07-21 JA CC No. Description Date NEW RESIDENCEAvenida NuestraLa Quinta, Ca. 92253APN: 770-173-0123/16" = 1'-0"1 Piping Plan Sprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 27 Viking 1/2 Light Concealed Temperature - 155 Finish - B Quick Response Model - Mirage SIN - VK494 K Factor - 4.9 VK494 4.9 1/2" 155 °F 5 Viking 1/2 Light Pendent Temperature - 200 Finish - C Special Response Model - Micromatic SIN - VK494 K Factor - 4.9 VK494 4.9 1/2" 200 °F : 32 Total No. of Sprinklers: 32 3/16" = 1'-0"5 UG 2x6 STUD WALL @ 16"O.C.2x6 STUD WALL @ 16"O.C.2x4 STUD WALL @ 16"O.C.Pant r y Cabi net Lin e n C a bin et Tall Cabinets U n d e rc o u nterWin e C o ole r Cabinet 42" High Wall30" Oven&Microwave36" CooktopFIREPLACE TV PH 10" ∅Solatube10" ∅Solatube10" ∅Solatube10" ∅SolatubeCAST IRONBATHVINTAGEK-700 BRASSFAUCETSPINSTRIPEK-T13134-3B BRASSFAUCETSPINSTRIPEK-T13134-3B BRASSFAUCETSPINSTRIPEK-T13134-3B BRASSFAUCETSPINSTRIPEK-T13134-3B 3'-117/8"7'-43/16"4'-103/4"3'3'4'-103/4" 5'3'GARAGE 10'-0" BEDROOM 3 10'-0" BEDROOM 2 10'-0" KITCHEN 10'-0" NOOK 10'-0" LIVING 10'-0" DINING 10'-0" MASTER BEDROOM 10'-0" MASTER BATH 10'-0" HIS W.I.C. 10'-0" HER W.I.C. 10'-0" LAUNDRY 10'-0" PANTRY 10'-0" W.I.C. >24sf W.I.C. >24sf BATH > 55 sf BATH > 55 sf BATH > 55 sf 5' - 2"14' - 0"4' - 4"7' - 4"14' - 0"7' - 2"6' - 8"4' - 6"7' - 9"4' - 10"5' - 10"4' - 2" 5' - 7"14' - 3"14' - 0"3' - 7"5' - 0"12' - 11"14' - 6"6' - 7"7' - 6"7' - 6"6' - 2"8' - 1"5' - 4" 2' - 8"12' - 0"2' - 11"3' - 8"11' - 11"3' - 7"5' - 7"2' - 6" 2' - 1"5' - 2" 3' - 9"12' - 0"3' - 5" HEAT ZONE 5' - 3"5' - 3"5' - 3"5' - 3"3' - 3"7' - 11"3' - 3"3' - 2"8' - 1"3' - 2"9' - 3"1' - 4"southwestfirepros.com Scale Project number Date Drawn by Checked bySouthwest Fire Pros31410 Reserve Drive Suite # 2Thousand Palms, Ca 92276Phone (760) 343-2233Fax (760( 343-2210e-mail southwestfirepros.comLic. No. C-16 10051653/16" = 1'-0"11/5/2021 12:24:23 PMFP-3 RCP 2021-215-R Nuestra 11-07-21 JA CC No. Description Date NEW RESIDENCEAvenida NuestraLa Quinta, Ca. 92253APN: 770-173-0123/16" = 1'-0"1 RCP Sprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 27 Viking 1/2 Light Concealed Temperature - 155 Finish - B Quick Response Model - Mirage SIN - VK494 K Factor - 4.9 VK494 4.9 1/2" 155 °F 5 Viking 1/2 Light Pendent Temperature - 200 Finish - C Special Response Model - Micromatic SIN - VK494 K Factor - 4.9 VK494 4.9 1/2" 200 °F : 32 Total No. of Sprinklers: 32 2x6 STUD WALL @ 16"O.C.2x6 STUD WALL @ 16"O.C.2x4 STUD WALL @ 16"O.C.Pant r y Cabi net Lin e n C a bin et Tall Cabinets U n d e rc o u nterWin e C o ole r Cabinet 42" High Wall30" Oven&Microwave36" CooktopFIREPLACE TV PH 10" ∅Solatube10" ∅Solatube10" ∅Solatube10" ∅SolatubeCAST IRONBATHVINTAGEK-700 BRASSFAUCETSPINSTRIPEK-T13134-3B BRASSFAUCETSPINSTRIPEK-T13134-3B BRASSFAUCETSPINSTRIPEK-T13134-3B BRASSFAUCETSPINSTRIPEK-T13134-3B 3'-117/8"7'-43/16"4'-103/4"3'3'4'-103/4" 5'3'INSPECTOR TEST DETAIL 5' 1" Ball Valve Access Panel (By Others) Exterior Wall of Building Inspector Test to Terminate in a Smooth Bore Corrosion Resistant Orfice With a Flow Equivalent to One Sprinkler NOTE: Access Panel Shall have sign Indicating Inspector Test CPVC HANGERS NO SCALE TOLCO FIG. 24 DOUBLE-FASTENER SIDE-MOUNT HANGER (OR EQUAL) SELF-DRILLING HEX HEAD SCREW TOLCO FIG. 23 DOUBLE-FASTENER STRAP TYPE HANGER (OR EQUAL) TOLCO FIG. 28M OFFSET HANGER (OR EQUAL) TOLCO FIG. 22 SINGLE-FASTENER STRAP-TYPE HANGER (OR EQUAL) TOLCO FIG. 28 DOUBLE-FASTENER STAND-OFF HANGER (OR EQUAL) TOLCO FIG. 29 DOUBLE-FASTENER DOUBLE OFFSET HANGER (OR EQUAL) CPVC HANGER SPACING PIPE SIZE 11/4" 1" MAXIMUM SUPPORT SPACING 6'-6" 6'-0" 2"8'-0" 11/2"7'-0" www.cadm ando.co.uk These blocks were brought to you by CADBlocksFree.com.For all of your 2D & 3D CAD outsource requirements visit us: C A D M A N D O www.cadblocksfree.com COVER WITH HINGED LID FINISHED GRADE DISC-TYPE WATER METER PLUG VALVE(TYP.)UNION(TYP.)42" High Wall10" ∅SolatubeCAST IRONBATHVINTAGEK-7007'-43/16"Water Supply Information Static Pressure: Residual Pressure: Residual Flow: Additional Hose Flow: 97.70 psi 89.20 psi 1350 GPM 0 GPM Calc-1 INSPECTORS TEST 1-1/4: PVC UG BY OTHERS1" RISERNOTIFICATION DEVICE BY OTHERSGARAGE 10'-0" BEDROOM 3 10'-0" BEDROOM 2 10'-0" KITCHEN 10'-0" NOOK 10'-0" LIVING 10'-0" DINING 10'-0" MASTER BEDROOM 10'-0" MASTER BATH 10'-0" HIS W.I.C. 10'-0" HER W.I.C. 10'-0" LAUNDRY 10'-0" PANTRY 10'-0" W.I.C. >24sf W.I.C. >24sf BATH > 55 sf BATH > 55 sf BATH > 55 sf 1" 7' -6" 1" 3' -10" 1" 5' -10" 1" 10' -5" 1" 14' -2" 1" 2' -11"1"7' -5"1"7' -0"1"7' -0"1" 17' -2" 1" 7' -0"1"3' -6"1"4' -6"1"4' -9"1" 21' -6"1"3' -3"1" 6' -8" 1" 4' -8"1"8' -1"1"5' -4"1" 2' -1" 1" 7' -4" 1" 7' -4" 1" 7' -4"1"14' -4"1" 4' -8"1"14' -0"1" 4' -8" 1" 3' -0" 1" 5' -9" 1" 0' -6" 1" 12' -0" 1" 12' -0" 1" 0' -8"1"4' -9"1" 3' -4" 1" 4' -3" 1" 5' -10"1"12' -0"1" 2' -2"1"14' -5"1" 7' -0" 1" 3' -6" 1" 0' -7" 1" 5' -2" 1" 7' -0" 1" 0' -11"1"4' -1"1" 2' -0" 1" 5' -0" 1" 2' -10" 1" 6' -7" 1" 0' -5"1"3' -2"1" 6' -2" Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-2 R-3 2 Gpm/SqFt 512 Max SqFt 31.0023 GPM 37.2915 Psi 5 GPM 0 GPM 8 6 12 3 4 7 BOR TOR DOM 1 1/4" x 4' -0"1" x 8' -0"1" x 2' -0"1"7' -9"1" 2' -10" Fire Sprinkler Riser Detail TOR BOR Domestic Supply Check Flow Control 1" CPVC Flow Switch Note Wiring by Others 300psi Gage Sprinkler Box with Wrench & two Sprinkler Heads Each Type 1/2" Drain to Outside1"1"1" Notification Device Wired by Others not to scale Module Must Connect to the Multi Station Smoke Alarm System and the Fire Sprinkler Flow Switch ( all wiring by others ) 1" RISER NOTE: 5psi shown as friction loss at 1" Water Meter MASTER BATH 10'-0" HIS W.I.C. 10'-0" HER W.I.C. 10'-0" 1" 5' -10"1"12' -0"1" 2' -2" Supply Point WM 5 BOR TOR DOM 1 1/4"19' -0"1 1/4" 17' -9" 1 1/4" 1' -6"1 1/4"0' -10"1 1/4" x 4' -0"1" x 8' -0"1" 1' -0"1" x 2' -0"1"7' -9"1" 2' -10" southwestfirepros.com Scale Project number Date Drawn by Checked bySouthwest Fire Pros31410 Reserve Drive Suite # 2Thousand Palms, Ca 92276Phone (760) 343-2233Fax (760( 343-2210e-mail southwestfirepros.comLic. No. C-16 1005165As indicated 11/8/2021 10:15:19 AMFP-2 Piping Plan 2021-215-R Nuestra 11-07-21 JA CC No. Description Date NEW RESIDENCEAvenida NuestraLa Quinta, Ca. 92253APN: 770-173-0123/16" = 1'-0"1 Piping Plan Sprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 27 Viking 1/2 Light Concealed Temperature - 155 Finish - B Quick Response Model - Mirage SIN - VK494 K Factor - 4.9 VK494 4.9 1/2" 155 °F 5 Viking 1/2 Light Pendent Temperature - 200 Finish - C Special Response Model - Micromatic SIN - VK494 K Factor - 4.9 VK494 4.9 1/2" 200 °F : 32 Total No. of Sprinklers: 32 3/16" = 1'-0"5 UG Southwest Fire Pros 31401 Reserve Drive Suite 2 Route 111 Thousand Palms, Ca.92276 760-343-2233 Job Name : New Residence.rvt#2 Drawing : Location : APN 770-173-012 Remote Area : Calc-2 Contract : Data File : New Residence.rvt#2 Area Calc-2.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire ProsPage 1 New Residence.rvt#2Date 10203040E50R60U70S80S90E100R110P120130140150100 200 300 400 500 600 700 800 900FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 77.3 C2 - Residual Pressure: 64 C2 - Residual Flow : 750 D1 - Elevation : 5.648 D2 - System Flow : 31.002 D2 - System Pressure : 37.292 Hose ( Demand ) : _______D3 - System Demand : 31.002 Safety Margin : 39.972 D1D2Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire ProsPage 2 New Residence.rvt#2Date Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire Pros Page 3 New Residence.rvt#2 Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure 5 77.3 64 750.0 77.263 31.0 37.292 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 1 10.04 4.9 7.04 13.0 0.05 256 2 11.0 7.11 3 11.0 8.55 4 11.0 11.23 TOR 11.0 19.05 DOM 2.99 24.29 5.0 BOR 1.0 26.53 WM -3.0 31.46 5 -3.0 37.29 6 10.04 4.9 7.04 13.0 0.05 256 7 11.0 6.96 8 11.0 10.89 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire Pros Page 4 New Residence.rvt#2 Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 1 10.04 4.90 13.00 1 N 7.0 7.960 150 7.040 to R 1.0 8.000 -0.416 2 11 13.0 1.101 15.960 0.0307 0.490 Vel = 4.38 2 11 13.00 1 R 1.0 7.000 150 7.114 to O 5.0 6.000 0.0 3 11 26.0 1.101 13.000 0.1105 1.437 Vel = 8.76 3 11 -12.64 1 4O 20.0 60.080 150 8.551 to 3R 3.0 23.000 0.0 4 11 13.36 1.101 83.080 0.0323 2.681 Vel = 4.50 4 11 12.64 1 2R 2.0 56.720 150 11.232 to O 5.0 14.000 0.0 TOR 11 26.0 1.101 N 7.0 70.720 0.1106 7.819 Vel = 8.76 TOR 11 0.0 1 R 1.0 8.010 150 19.051 to N 7.0 8.000 3.469 DOM 2.99 26.0 1.101 16.010 0.1106 1.771 Vel = 8.76 DOM 2.99 + 5.00 5.00 1 N 7.0 1.990 150 24.291 to 7.000 0.862 BOR 1 31.0 1.101 8.990 0.1531 1.376 Vel = 10.45 BOR 1 0.0 1.25 3N 24.0 41.830 150 26.529 to 24.000 1.732 WM -3 31.0 1.394 65.830 0.0485 3.194 Vel = 6.52 WM -3 0.0 1.25 5N 40.0 9.240 150 31.455 to 8.000 5.000 * * Fixed Loss = 5 5 -3 31.0 1.394 17.240 0.0485 0.837 Vel = 6.52 0.0 5 31.00 37.292 K Factor = 5.08 6 10.04 4.90 13.00 1 N 7.0 2.940 150 7.040 to R 1.0 8.000 -0.416 7 11 13.0 1.101 10.940 0.0307 0.336 Vel = 4.38 7 11 0.0 1 5.020 150 6.960 to 0.0 2 11 13.0 1.101 5.020 0.0307 0.154 Vel = 4.38 0.0 2 13.00 7.114 K Factor = 4.87 3 11 12.64 1 5O 25.0 53.440 150 8.551 to 2R 2.0 27.000 0.0 8 11 12.64 1.101 80.440 0.0291 2.342 Vel = 4.26 8 11 0.0 1 O 5.0 6.650 150 10.893 to 5.000 0.0 4 11 12.64 1.101 11.650 0.0291 0.339 Vel = 4.26 0.0 4 12.64 11.232 K Factor = 3.77 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 1 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 1. DESCRIPTION Viking Freedom® Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile small-diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “push-on”, “thread-off” design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2” (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS UL Listed (C-UL-US-EU): Category VKKW Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) Glass-bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-C51000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 or Stainless Steel UNS-S30400 Spring: Beryllium Nickel Solder: Eutectic (Also refer to the current Viking price list.) Viking Freedom® Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 200 °F (93 °C) = E For example, sprinkler VK494 with a Brass finish and a 200 °F (93 °C) temperature rating = Part No. 20759AE. Base Part No. 13504 (2-3/4” diameter), Base Part No. 13642 (3-5/16” diameter), or Base Part No. 15394 (square cover plate, 3-5/16”) Base Part No. 21876 (2-3/4” diameter) or Base Part No. 21875 (3-5/16” diameter). Replaces Form No. F_012116 Rev 18.1 (Added P65 Warning.) FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 2 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = M-/B Temperature Suffix: 135 °F/57 °C = A For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13504FA. Refer to Table 1. (Also refer to the Viking website.) A. Heavy Duty Part No. 14047W/B** (available since 2006), or B. Head Cabinet Wrench Part No. 14031*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a ½” ratchet (not available from Viking). ***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Part No. 01731A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly. . Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres - sure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. 1 2 3 4 4 4 Ordinary 155 °F (68 °C)100 °F (38 °C)135 °F (57 °C)13504 or 218766 13642 or 218756 15394 Red Intermediate 200 °F (93 °C)150 °F (65 °C)135 °F (57 °C)13504 or 218766 13642 or 218756 15394 Green Brass and ENT 6: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 5: ENT 1.The sprinkler temperature rating is stamped on the deflector. 2.Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3.Maximum ambient temperature for cover assembly is 100 °F (38 °C). 4.Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 5.The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. 6.Stainless Steel versions are not available with any finishes or paint. FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 3 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 1 SIN - U.S.2 20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar) 6 GPM (LPM)3,5 155 °F (68 °C), 200 °F (93 °C) Temperature Rated Sprinklers 4 12 X 12 (3.7 X 3.7) 13 (49.2) 7.0 (0.48) Refer to Figure 2 Concealed with Cover Plate Assembly. See Footnote 8. See Footnotes 7,9, 10, & 11 8 (2.4) 14 X 14 (4.3 X 4.3) 13 (49.2) 7.0 (0.48) 16 X 16 (4.9 X 4.9) 13 (49.2) 7.0 (0.48) 18 X 18 (5.5 X 5.5) 17 (64.4) 12.0 (0.83) 20 X 20 (6.1 X 6.1) 20 (75.7) 16.7 (1.15) 1.Part number shown is the base part number. For complete part number, refer to current Viking price schedule. 2.Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3.This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 4.Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. 5.Meets New York City requirements, effective July 1, 2008. 6.For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum “Flow” and “Pressure” used. 7.Cover Temperature Rating is 135 °F (57 °C). Cover Part No. 135041, 136421 (large diameter), or 153941 (square cover plate). 8.Other paint colors are available on request with the same listings as the standard finish colors. Stainless Steel cover plates are not available with any finishes or paint. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 8. 10.C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) 11.Stainless Steel Cover plate temperature rating is 135 °F (57 °C). Stainless Steel Cover Part Numbers: 218761 and 218751 (large diameter). FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 4 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) : When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover - age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: •The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, •Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. •Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: - • • Step 1: Step 2: FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 5 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 NOTE: to approximately 13/16” (21 mm) below the sprinkler body. All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Replaces Form No. F_012116 Rev 18.1 (Added P65 Warning.) OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org December 6, 2021 Southwest Fire Pros 31410 Reserve Drive #2 Thousand Palms, CA 92276 Re: Residential Fire Sprinkler Plan Review – DUCEY RESIDENCE FSS2021-0254 / 78620 AVENIDA NUESTRA, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 78620 AVENIDA NUESTRA PERMIT#: FSS2021-0254 DATE ISSUED: 12/6/2021 DESCRIPTION: DUCEY RESIDENCE CONTRACTOR: SW FIRE PROS HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.