FSS2021-0260
ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 (760)625-5908 JCFIREPROTECTION@V ERIZON.NET CONTRACTOR J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 (760)625-5908 JCFIREPROTECTION@V ERIZON.NET OWNER SILVERROCK PHASE 1 3551 FORTUNA RANCH RD ENCINITAS CA 92924 (760)625-5908 OWNER (HISTORY) CITY OF LA QUINTA P O BOX 1504 LA QUINTA CA 92247 (760)625-5908 CONDITIONS Description: MONTAGE HOTEL - POOL BAR Type: FIRE SPRINKLER (WEB)Subtype: Status: ISSUED Applied: 11/24/2021 ECON Parcel No: 777490012 Site Address: 79195 AHMANSON LN LA QUINTA,CA 92253 Approved: 7/6/2022 KHET Subdivision: Block: Lot: Issued: 7/6/2022 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $10,000.00 Occupancy Type: Construction Type: Expired: 1/2/2023 ECON No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Friday, March 03, 2023 10:33:54 AM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0260 BOND INFORMATION INSPECTIONS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE - ETRAKIT (2 WK) KOHL HETRICK 11/24/2021 12/10/2021 12/14/2021 REVISIONS REQUIRED SEE ATTACHMENTS 1ST PERMIT TECH – ETRAKIT (1 DAY) PERMIT TECH BUCKET 11/24/2021 11/29/2021 11/29/2021 COMPLETE 2ND FIRE (1 WK)KOHL HETRICK 6/6/2022 6/13/2022 7/6/2022 APPROVED SEE ATTACHMENTS PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS COMMERCIAL/INDUSTR IAL 101-0000-42421 0 $250.00 $250.00 7/6/22 WEB12430 638017066 20 CREDIT 996335 ECON FIRE SPRINKLER SYSTEMS COMMERCIAL/INDUSTR IAL PC 101-0000-42420 0 $417.00 $417.00 7/6/22 WEB12430 638017066 20 CREDIT 996335 ECON Total Paid for FIRE FEES: $667.00 $667.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 7/6/22 WEB12430 638017066 20 CREDIT 996335 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 7/6/22 WEB12430 638017066 20 CREDIT 996335 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$683.00 $683.00 Printed: Friday, March 03, 2023 10:33:54 AM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0260 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/24/2021 Etrakit Contractor 1ST SUBMITTAL FELT HANGERS AKW-Submittal-Hanger- Groups-WM copy.pdf 1 DOC 11/24/2021 Etrakit Contractor 1ST SUBMITTAL STEEL PIPE All-Sch-7-Sch-10-Sch-40 copy (1).pdf 1 DOC 11/24/2021 Etrakit Contractor 1ST SUBMITTAL PIPE SCH 10 AND 40 copy 2 (1).pdf 1 DOC 11/24/2021 Etrakit Contractor 1ST SUBMITTAL IRON FITTINGS SCI Ductile Iron Threaded Fittings copy copy 2.pdf 1 DOC 11/24/2021 Etrakit Contractor 1ST SUBMITTAL VK462 vk462 k5.6 copy.pdf 1 DOC 11/24/2021 Etrakit Contractor 1ST SUBMITTAL CATALOG Sammys-Catalog-2012 copy (1) copy.pdf 1 DOC 11/24/2021 Etrakit Contractor 1ST SUBMITTAL TRANSMITTAL 211313-003.0 - Fire Sprinkler (H1) SD_BHD- Gensler copy.pdf 1 DOC 11/24/2021 Etrakit Contractor 1ST SUBMITTAL FP-2 Montage Pool Bar Fire Sprinkler FP2.pdf 1 DOC 11/24/2021 Etrakit Contractor 1ST SUBMITTAL FP-1 Montage Pool Bar Fire Sprinkler FP1.pdf 1 DOC 11/24/2021 Etrakit Contractor 1ST SUBMITTAL POOL HYDRAULIC POOL BAR CALC.PDF 1 DOC 11/24/2021 Etrakit Contractor 1ST SUBMITTAL FP-3 Montage Pool Bar Fire Sprinkler FP3.pdf 1 DOC 11/24/2021 Etrakit Contractor 1ST SUBMITTAL APPLICATION FIRE APPLICATION SEPTEMBER 2019 FEE UPDATE REVISED 3 .pdf 1 DOC 11/24/2021 Etrakit Contractor 1ST SUBMITTAL THREADED ROD AKW-Submittal-All- Threaded-Rods-WM copy.pdf 1 Printed: Friday, March 03, 2023 10:33:54 AM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0260 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/24/2021 Etrakit Contractor 1ST SUBMITTAL IRON FITINGS AKW-Submittal-DI- Fittings-BIS-WM copy.pdf 1 DOC 3/3/2022 Etrakit Contractor anvil flex coupling .pdf 1 DOC 3/3/2022 Etrakit Contractor victaulic zero flex coupling .pdf 1 DOC 3/3/2022 Etrakit Contractor victaulic flex coupling .pdf 1 DOC 3/3/2022 Etrakit Contractor Gruvlok-Couplings.pdf 1 DOC 3/3/2022 Etrakit Contractor 100 tong flex coupling.pdf 1 DOC 6/6/2022 Etrakit Contractor SEOR Stamped set / revised set 6/6/22 211313-007.0 Fire Sprinkler (Pool Bar) Fire Dept. Submittal - CEI - G.pdf 1 DOC 12/14/2021 KOHL HETRICK FSS2021-0260 - 1ST REVIEW - FIRE CORRECTIONS LETTER.pdf FSS2021-0260 - 1ST REVIEW - FIRE CORRECTIONS LETTER.pdf 1 DOC 12/14/2021 KOHL HETRICK FSS2021-0260 - 1ST REVIEW - FIRE PLAN COMMENTS.pdf FSS2021-0260 - 1ST REVIEW - FIRE PLAN COMMENTS.pdf 1 DOC 7/6/2022 KOHL HETRICK FSS2021-0260 - APPROVED PLANS AND CALCS.pdf FSS2021-0260 - APPROVED PLANS AND CALCS.pdf 1 DOC 7/6/2022 KOHL HETRICK FSS2021-0260 - COA AND JOB CARD.pdf FSS2021-0260 - COA AND JOB CARD.pdf 1 Printed: Friday, March 03, 2023 10:33:54 AM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0260 SUPPORT INTERVAL OF STEEL LINES:LINES PERPENDICULAR TO JOISTS:STEEL SPRINKLER LINES 2" AND LARGER THAT RUN PERPENDICULAR TOJOISTS SHALL BE SUPPORTED TO THE JOISTS AT THE FOLLOWINGMAXIMUM INTERVALS:2-1/2" LINE SHALL BE SUPPORTED AT 10'-0" OC MAX4" LINE SHALL BE SUPPORTED AT 10'-0" OC MAXSTEEL LINES PERPENDICUALR TO JOISTS THAT ARE LESS THAN 2" MAYBE SUPPORTED AT THE INTERVAL REQUIRED BY NFPA 13.LINES PARALLEL TO JOISTS:STEEL LINES PARALLEL TO JOISTS MAY BE SUPPORTED AT THEINTERVAL REQUIRED BY NFPA 13CEISUPPORT INTERVAL OF CPVC LINES:LINES PERPENDICULAR TO JOISTS:CPVC LINES PERPENDICUALR TO JOISTS THAT ARE LESS THAN 3" MAYBE SUPPORTED AT THE INTERVAL REQUIRED BY NFPA 13.LINES PARALLEL TO JOISTS:CPVC LINES PARALLEL TO JOISTS THAT ARE LESS THAN 3" MAY BESUPPORTED AT THE INTERVAL REQUIRED BY NFPA 13CEIGC NOTE:LINES SHALL BE LOCATED SUCH THATTHEY COMPLY WITH JOISTMANUFACTURER'S WEB PENETRATIONRESTRCTIONS IN THE VICINITY OFSUPPORT POINTS. (SEE ICC# ESR-1225)CEI LIMIT SIDE MOUNTED PIPES TO 1-1/2" ANDSMALLERCEI SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1DATE: 6/1/2022HOTEL - LA QUINTA - JCP\004 WORKING\CALCS\POOL BAR CALC.SDFJOB TITLE: POOL BAR CALC (.10/3002)(148 SF MAX)(14.8 GPM MIN)(+100 GPM HOSE) WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ’D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SRC 92.6 72.9 2760.0 90.3 859.0 73.8 Available pressure is 16.5 psi (18%) greater than required pressure. AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 859.0 GPMTOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPMOTHER HOSE STREAM ALLOWANCES 100.0 GPMTOTAL DISCHARGE FROM ACTIVE SPRINKLERS 759.0 GPM NODE ANALYSIS DATA PRESSURENODE TAG ELEVATION NODE TYPE TOTAL NORMAL DISCHARGE (FT) (PSI) (PSI) (GPM) P1 8.8 K= 5.60 8.1 8.1 15.9P2 8.8 K= 5.60 8.6 8.6 16.5P3 8.8 K= 5.60 9.7 9.7 17.4P4 8.8 K= 5.60 8.9 8.9 16.7P5 8.8 K= 5.60 9.2 9.2 16.9P6 8.8 K= 5.60 10.3 10.3 17.9P7 8.8 K= 5.60 7.4 7.4 15.2P8 8.8 K= 5.60 7.4 7.4 15.3P9 8.8 K= 5.60 7.7 7.7 15.5P10 8.8 K= 5.60 8.2 8.2 16.1P11 8.8 K= 5.60 9.2 9.2 17.0P12 8.8 K= 5.60 9.0 9.0 16.8P13 8.8 K= 5.60 9.3 9.3 17.0P14 8.8 K= 5.60 10.3 10.3 18.0P15 8.8 K= 5.60 8.0 8.0 15.8P16 8.8 K= 5.60 8.2 8.2 16.1P17 8.8 K= 5.60 8.5 8.5 16.3P18 8.8 K= 5.60 9.1 9.1 16.9P19 8.8 K= 5.60 10.5 10.5 18.1P20 8.8 K= 5.60 13.2 13.2 20.4P21 8.8 K= 5.60 8.7 8.7 16.5P22 8.8 K= 5.60 9.9 9.9 17.6P23 8.8 K= 5.60 10.7 10.7 18.3P24 8.8 K= 5.60 16.9 16.9 23.0P25 8.8 K= 5.60 18.0 18.0 23.8P26 8.8 K= 5.60 7.0 7.0 14.8P27 8.8 K= 5.60 7.6 7.6 15.5P28 8.8 K= 5.60 7.9 7.9 15.7P29 8.8 K= 5.60 8.4 8.4 16.2P30 8.8 K= 5.60 10.0 10.0 17.7P31 8.8 K= 5.60 10.3 10.3 18.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2DATE: 6/1/2022HOTEL - LA QUINTA - JCP\004 WORKING\CALCS\POOL BAR CALC.SDFJOB TITLE: POOL BAR CALC (.10/3002)(148 SF MAX)(14.8 GPM MIN)(+100 GPM HOSE) NODE ANALYSIS DATA PRESSURENODE TAG ELEVATION NODE TYPE TOTAL NORMAL DISCHARGE (FT) (PSI) (PSI) (GPM) P32 8.8 K= 5.60 10.6 10.6 18.2P33 8.8 K= 5.60 11.7 11.7 19.2P34 8.8 K= 5.60 16.3 16.3 22.6P35 8.8 K= 5.60 17.7 17.7 23.5P36 8.8 K= 5.60 18.5 18.5 24.1P37 8.8 K= 5.60 16.2 16.2 22.5P38 8.8 K= 5.60 17.4 17.4 23.3P39 8.8 K= 5.60 19.3 19.3 24.6P40 8.8 K= 5.60 18.0 18.0 23.8P41 8.8 K= 5.60 18.6 18.6 24.11 10.0 - - - - 7.8 7.6 - - -2 10.0 - - - - 8.7 8.3 - - -3 10.0 - - - - 9.8 9.0 - - -4 10.0 - - - - 8.9 8.8 - - -5 10.0 - - - - 9.2 8.9 - - -6 10.0 - - - - 10.4 9.6 - - -7 10.0 - - - - 7.1 6.9 - - -8 10.0 - - - - 7.4 7.1 - - -9 10.0 - - - - 7.6 7.0 - - -10 10.0 - - - - 8.2 7.1 - - -11 10.0 - - - - 9.3 7.4 - - -12 10.0 - - - - 9.3 9.2 - - -13 10.0 - - - - 9.6 9.3 - - -14 10.0 - - - - 10.8 10.0 - - -15 10.0 - - - - 8.0 7.7 - - -16 10.0 - - - - 8.2 7.9 - - -17 10.0 - - - - 8.5 7.8 - - -18 10.0 - - - - 9.1 7.8 - - -19 10.0 - - - - 10.6 8.4 - - -20 10.0 - - - - 13.9 10.6 - - -21 10.0 - - - - 8.7 8.5 - - -22 10.0 - - - - 10.0 9.6 - - -23 10.0 - - - - 10.9 10.0 - - -24 10.0 - - - - 16.9 16.4 - - -25 10.0 - - - - 18.6 17.9 - - -26 10.0 - - - - 6.9 6.7 - - -27 10.0 - - - - 7.9 7.6 - - -28 10.0 - - - - 8.2 7.5 - - -29 10.0 - - - - 8.7 7.5 - - -30 10.0 - - - - 10.3 8.3 - - -31 10.0 - - - - 10.7 10.6 - - -32 10.0 - - - - 11.0 10.6 - - -33 10.0 - - - - 12.3 11.3 - - -34 10.0 - - - - 16.3 15.9 - - -35 10.0 - - - - 18.2 17.6 - - -36 10.0 - - - - 19.1 17.6 - - -37 10.0 - - - - 16.6 16.2 - - -38 10.0 - - - - 17.9 17.3 - - -39 10.0 - - - - 20.0 18.4 - - -40 10.0 - - - - 18.6 18.4 - - -41 10.0 - - - - 19.2 18.5 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3DATE: 6/1/2022HOTEL - LA QUINTA - JCP\004 WORKING\CALCS\POOL BAR CALC.SDFJOB TITLE: POOL BAR CALC (.10/3002)(148 SF MAX)(14.8 GPM MIN)(+100 GPM HOSE) NODE ANALYSIS DATA PRESSURENODE TAG ELEVATION NODE TYPE TOTAL NORMAL DISCHARGE (FT) (PSI) (PSI) (GPM) M1 10.0 - - - - 12.4 12.1 - - -M2 10.0 - - - - 12.9 11.2 - - -M3 10.0 - - - - 13.6 11.2 - - -M4 10.0 - - - - 15.2 9.9 - - -M5 10.0 - - - - 22.3 21.9 - - -M6 10.0 - - - - 23.2 21.3 - - -M1A 10.0 - - - - 21.1 20.8 - - -M2A 10.0 - - - - 21.4 20.7 - - -M3A 10.0 - - - - 22.6 22.4 - - -M4A 10.0 - - - - 22.9 22.7 - - -TOR 10.0 - - - - 31.9 29.9 - - -BOR 0.5 - - - - 42.4 40.4 - - -UG2 -3.0 - - - - 70.6 70.5 - - -UG4 -3.0 - - - - 70.1 70.1 - - -UG5 -3.0 - - - - 45.8 43.8 - - -UG6 -3.0 HOSE STREAM 69.5 69.4 100.0HS1 -3.0 - - - - 70.3 70.3 - - -BF1 3.0 - - - - 68.1 68.1 - - -BF2 3.0 - - - - 71.1 71.1 - - -SRC -3.0 SOURCE 73.8 73.8 859.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4DATE: 6/1/2022HOTEL - LA QUINTA - JCP\004 WORKING\CALCS\POOL BAR CALC.SDFJOB TITLE: POOL BAR CALC (.10/3002)(148 SF MAX)(14.8 GPM MIN)(+100 GPM HOSE) PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. PT P2 DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (PSI) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -15.9 1.049 PL 1.25 PF 0.3P1 8.8 8.1 8.1 15.9 5.9 120 FTG E PE -0.51 10.0 7.8 7.6 0.0 0.085 TL 3.25 PV 0.2 Pipe: 2 -16.5 1.049 PL 1.25 PF 0.6P2 8.8 8.6 8.6 16.5 6.1 120 FTG T PE -0.52 10.0 8.7 8.3 0.0 0.091 TL 6.25 PV 0.3 Pipe: 3 -17.4 1.049 PL 1.25 PF 0.6P3 8.8 9.7 9.7 17.4 6.5 120 FTG T PE -0.53 10.0 9.8 9.0 0.0 0.101 TL 6.25 PV 0.3 Pipe: 4 -16.7 1.049 PL 1.25 PF 0.6P4 8.8 8.9 8.9 16.7 6.2 120 FTG T PE -0.54 10.0 8.9 8.8 0.0 0.093 TL 6.25 PV 0.3 Pipe: 5 -16.9 1.049 PL 1.25 PF 0.6P5 8.8 9.2 9.2 16.9 6.3 120 FTG T PE -0.55 10.0 9.2 8.9 0.0 0.096 TL 6.25 PV 0.3 Pipe: 6 -17.9 1.049 PL 1.25 PF 0.7P6 8.8 10.3 10.3 17.9 6.7 120 FTG T PE -0.56 10.0 10.4 9.6 0.0 0.106 TL 6.25 PV 0.3 Pipe: 7 -15.2 1.049 PL 1.25 PF 0.3P7 8.8 7.4 7.4 15.2 5.6 120 FTG E PE -0.57 10.0 7.1 6.9 0.0 0.078 TL 3.25 PV 0.2 Pipe: 8 -15.3 1.049 PL 1.25 PF 0.5P8 8.8 7.4 7.4 15.3 5.7 120 FTG T PE -0.58 10.0 7.4 7.1 0.0 0.079 TL 6.25 PV 0.2 Pipe: 9 -15.5 1.049 PL 1.25 PF 0.5P9 8.8 7.7 7.7 15.5 5.8 120 FTG T PE -0.59 10.0 7.6 7.0 0.0 0.081 TL 6.25 PV 0.2 Pipe: 10 -16.1 1.049 PL 1.25 PF 0.5P10 8.8 8.2 8.2 16.1 6.0 120 FTG T PE -0.510 10.0 8.2 7.1 0.0 0.087 TL 6.25 PV 0.2 Pipe: 11 -17.0 1.049 PL 1.25 PF 0.6P11 8.8 9.2 9.2 17.0 6.3 120 FTG T PE -0.511 10.0 9.3 7.4 0.0 0.096 TL 6.25 PV 0.3 Pipe: 12 -16.8 1.049 PL 2.25 PF 0.9P12 8.8 9.0 9.0 16.8 6.2 120 FTG ET PE -0.512 10.0 9.3 9.2 0.0 0.094 TL 9.25 PV 0.3 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5DATE: 6/1/2022HOTEL - LA QUINTA - JCP\004 WORKING\CALCS\POOL BAR CALC.SDFJOB TITLE: POOL BAR CALC (.10/3002)(148 SF MAX)(14.8 GPM MIN)(+100 GPM HOSE) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. PT P2 DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (PSI) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -17.0 1.049 PL 2.25 PF 0.9P13 8.8 9.3 9.3 17.0 6.3 120 FTG ET PE -0.513 10.0 9.6 9.3 0.0 0.097 TL 9.25 PV 0.3 Pipe: 14 -18.0 1.049 PL 2.25 PF 1.0P14 8.8 10.3 10.3 18.0 6.7 120 FTG ET PE -0.514 10.0 10.8 10.0 0.0 0.107 TL 9.25 PV 0.3 Pipe: 16 -15.8 1.049 PL 1.25 PF 0.5P15 8.8 8.0 8.0 15.8 5.9 120 FTG T PE -0.515 10.0 8.0 7.7 0.0 0.084 TL 6.25 PV 0.2 Pipe: 18 -16.1 1.049 PL 1.25 PF 0.5P16 8.8 8.2 8.2 16.1 6.0 120 FTG T PE -0.516 10.0 8.2 7.9 0.0 0.087 TL 6.25 PV 0.2 Pipe: 19 -16.3 1.049 PL 1.25 PF 0.6P17 8.8 8.5 8.5 16.3 6.1 120 FTG T PE -0.517 10.0 8.5 7.8 0.0 0.090 TL 6.25 PV 0.2 Pipe: 20 -16.9 1.049 PL 1.25 PF 0.6P18 8.8 9.1 9.1 16.9 6.3 120 FTG T PE -0.518 10.0 9.1 7.8 0.0 0.095 TL 6.25 PV 0.3 Pipe: 21 -18.1 1.049 PL 1.25 PF 0.7P19 8.8 10.5 10.5 18.1 6.7 120 FTG T PE -0.519 10.0 10.6 8.4 0.0 0.108 TL 6.25 PV 0.3 Pipe: 22 -20.4 1.049 PL 2.25 PF 1.2P20 8.8 13.2 13.2 20.4 7.6 120 FTG ET PE -0.520 10.0 13.9 10.6 0.0 0.135 TL 9.25 PV 0.4 Pipe: 23 -16.5 1.049 PL 1.25 PF 0.6P21 8.8 8.7 8.7 16.5 6.1 120 FTG T PE -0.521 10.0 8.7 8.5 0.0 0.091 TL 6.25 PV 0.3 Pipe: 24 -17.6 1.049 PL 1.25 PF 0.6P22 8.8 9.9 9.9 17.6 6.5 120 FTG T PE -0.522 10.0 10.0 9.6 0.0 0.103 TL 6.25 PV 0.3 Pipe: 25 -18.3 1.049 PL 1.25 PF 0.7P23 8.8 10.7 10.7 18.3 6.8 120 FTG T PE -0.523 10.0 10.9 10.0 0.0 0.111 TL 6.25 PV 0.3 Pipe: 26 -23.0 1.049 PL 1.25 PF 0.5P24 8.8 16.9 16.9 23.0 8.5 120 FTG E PE -0.524 10.0 16.9 16.4 0.0 0.169 TL 3.25 PV 0.5 Pipe: 27 -23.8 1.049 PL 1.25 PF 1.1P25 8.8 18.0 18.0 23.8 8.8 120 FTG T PE -0.525 10.0 18.6 17.9 0.0 0.179 TL 6.25 PV 0.5 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6DATE: 6/1/2022HOTEL - LA QUINTA - JCP\004 WORKING\CALCS\POOL BAR CALC.SDFJOB TITLE: POOL BAR CALC (.10/3002)(148 SF MAX)(14.8 GPM MIN)(+100 GPM HOSE) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. PT P2 DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (PSI) (PSI) (GPM) FL/FT (PSI) Pipe: 28 -14.8 1.049 PL 1.25 PF 0.5P26 8.8 7.0 7.0 14.8 5.5 120 FTG T PE -0.526 10.0 6.9 6.7 0.0 0.075 TL 6.25 PV 0.2 Pipe: 29 -15.5 1.049 PL 2.75 PF 0.8P27 8.8 7.6 7.6 15.5 5.7 120 FTG ET PE -0.527 10.0 7.9 7.6 0.0 0.081 TL 9.75 PV 0.2 Pipe: 30 -15.7 1.049 PL 2.75 PF 0.8P28 8.8 7.9 7.9 15.7 5.8 120 FTG ET PE -0.528 10.0 8.2 7.5 0.0 0.083 TL 9.75 PV 0.2 Pipe: 31 -16.2 1.049 PL 2.75 PF 0.9P29 8.8 8.4 8.4 16.2 6.0 120 FTG ET PE -0.529 10.0 8.7 7.5 0.0 0.088 TL 9.75 PV 0.2 Pipe: 32 -17.7 1.049 PL 1.75 PF 0.9P30 8.8 10.0 10.0 17.7 6.6 120 FTG ET PE -0.530 10.0 10.3 8.3 0.0 0.103 TL 8.75 PV 0.3 Pipe: 33 -18.0 1.049 PL 2.00 PF 1.0P31 8.8 10.3 10.3 18.0 6.7 120 FTG ET PE -0.531 10.0 10.7 10.6 0.0 0.107 TL 9.00 PV 0.3 Pipe: 34 -18.2 1.049 PL 2.00 PF 1.0P32 8.8 10.6 10.6 18.2 6.8 120 FTG ET PE -0.532 10.0 11.0 10.6 0.0 0.110 TL 9.00 PV 0.3 Pipe: 35 -19.2 1.049 PL 2.00 PF 1.1P33 8.8 11.7 11.7 19.2 7.1 120 FTG ET PE -0.533 10.0 12.3 11.3 0.0 0.120 TL 9.00 PV 0.3 Pipe: 36 -22.6 1.049 PL 1.25 PF 0.5P34 8.8 16.3 16.3 22.6 8.4 120 FTG E PE -0.534 10.0 16.3 15.9 0.0 0.164 TL 3.25 PV 0.5 Pipe: 37 -23.5 1.049 PL 1.25 PF 1.1P35 8.8 17.7 17.7 23.5 8.7 120 FTG T PE -0.535 10.0 18.2 17.6 0.0 0.176 TL 6.25 PV 0.5 Pipe: 38 -24.1 1.049 PL 1.25 PF 1.1P36 8.8 18.5 18.5 24.1 8.9 120 FTG T PE -0.536 10.0 19.1 17.6 0.0 0.183 TL 6.25 PV 0.5 Pipe: 39 -22.5 1.049 PL 1.25 PF 1.0P37 8.8 16.2 16.2 22.5 8.4 120 FTG T PE -0.537 10.0 16.6 16.2 0.0 0.162 TL 6.25 PV 0.5 Pipe: 40 -23.3 1.049 PL 1.25 PF 1.1P38 8.8 17.4 17.4 23.3 8.7 120 FTG T PE -0.538 10.0 17.9 17.3 0.0 0.173 TL 6.25 PV 0.5 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7DATE: 6/1/2022HOTEL - LA QUINTA - JCP\004 WORKING\CALCS\POOL BAR CALC.SDFJOB TITLE: POOL BAR CALC (.10/3002)(148 SF MAX)(14.8 GPM MIN)(+100 GPM HOSE) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. PT P2 DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (PSI) (PSI) (GPM) FL/FT (PSI) Pipe: 41 -24.6 1.049 PL 1.25 PF 1.2P39 8.8 19.3 19.3 24.6 9.1 120 FTG T PE -0.539 10.0 20.0 18.4 0.0 0.191 TL 6.25 PV 0.6 Pipe: 42 -23.8 1.049 PL 1.25 PF 1.1P40 8.8 18.0 18.0 23.8 8.8 120 FTG T PE -0.540 10.0 18.6 18.4 0.0 0.179 TL 6.25 PV 0.5 Pipe: 43 -24.1 1.049 PL 1.25 PF 1.2P41 8.8 18.6 18.6 24.1 9.0 120 FTG T PE -0.541 10.0 19.2 18.5 0.0 0.184 TL 6.25 PV 0.5 Pipe: 46 -15.9 1.049 PL 10.00 PF 0.91 10.0 7.8 7.6 0.0 5.9 120 FTG ---- PE 0.02 10.0 8.7 8.3 0.0 0.085 TL 10.00 PV 0.2 Pipe: 47 -32.4 1.380 PL 13.00 PF 1.12 10.0 8.7 8.3 0.0 6.9 120 FTG ---- PE 0.03 10.0 9.8 9.0 0.0 0.083 TL 13.00 PV 0.3 Pipe: 48 -49.8 1.380 PL 8.50 PF 2.73 10.0 9.8 9.0 0.0 10.7 120 FTG T PE 0.0M1 10.0 12.4 12.1 0.0 0.185 TL 14.50 PV 0.8 Pipe: 49 -16.7 1.380 PL 13.00 PF 0.34 10.0 8.9 8.8 0.0 3.6 120 FTG ---- PE 0.05 10.0 9.2 8.9 0.0 0.024 TL 13.00 PV 0.1 Pipe: 50 -33.6 1.380 PL 13.00 PF 1.25 10.0 9.2 8.9 0.0 7.2 120 FTG ---- PE 0.06 10.0 10.4 9.6 0.0 0.089 TL 13.00 PV 0.3 Pipe: 51 -51.5 1.380 PL 4.50 PF 2.16 10.0 10.4 9.6 0.0 11.1 120 FTG T PE 0.0M1 10.0 12.4 12.1 0.0 0.197 TL 10.50 PV 0.8 Pipe: 52 -15.2 1.049 PL 3.75 PF 0.37 10.0 7.1 6.9 0.0 5.6 120 FTG ---- PE 0.08 10.0 7.4 7.1 0.0 0.078 TL 3.75 PV 0.2 Pipe: 53 -30.4 1.380 PL 3.75 PF 0.38 10.0 7.4 7.1 0.0 6.5 120 FTG ---- PE 0.09 10.0 7.6 7.0 0.0 0.074 TL 3.75 PV 0.3 Pipe: 54 -46.0 1.380 PL 3.75 PF 0.69 10.0 7.6 7.0 0.0 9.9 120 FTG ---- PE 0.010 10.0 8.2 7.1 0.0 0.160 TL 3.75 PV 0.7 Pipe: 55 -62.0 1.380 PL 3.75 PF 1.010 10.0 8.2 7.1 0.0 13.3 120 FTG ---- PE 0.011 10.0 9.3 7.4 0.0 0.278 TL 3.75 PV 1.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8DATE: 6/1/2022HOTEL - LA QUINTA - JCP\004 WORKING\CALCS\POOL BAR CALC.SDFJOB TITLE: POOL BAR CALC (.10/3002)(148 SF MAX)(14.8 GPM MIN)(+100 GPM HOSE) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. PT P2 DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (PSI) (PSI) (GPM) FL/FT (PSI) Pipe: 56 -79.1 1.380 PL 2.25 PF 3.611 10.0 9.3 7.4 0.0 17.0 120 FTG T PE 0.0M2 10.0 12.9 11.2 0.0 0.435 TL 8.25 PV 1.9 Pipe: 57 -16.8 1.380 PL 13.50 PF 0.312 10.0 9.3 9.2 0.0 3.6 120 FTG ---- PE 0.013 10.0 9.6 9.3 0.0 0.025 TL 13.50 PV 0.1 Pipe: 58 -33.8 1.380 PL 13.00 PF 1.213 10.0 9.6 9.3 0.0 7.3 120 FTG ---- PE 0.014 10.0 10.8 10.0 0.0 0.090 TL 13.00 PV 0.4 Pipe: 59 -51.8 1.380 PL 4.50 PF 2.114 10.0 10.8 10.0 0.0 11.1 120 FTG T PE 0.0M2 10.0 12.9 11.2 0.0 0.199 TL 10.50 PV 0.8 Pipe: 59A -15.8 1.049 PL 3.50 PF 0.315 10.0 8.0 7.7 0.0 5.9 120 FTG ---- PE 0.016 10.0 8.2 7.9 0.0 0.084 TL 3.50 PV 0.2 Pipe: 60 -31.9 1.380 PL 3.50 PF 0.316 10.0 8.2 7.9 0.0 6.8 120 FTG ---- PE 0.017 10.0 8.5 7.8 0.0 0.081 TL 3.50 PV 0.3 Pipe: 61 -48.2 1.380 PL 3.50 PF 0.617 10.0 8.5 7.8 0.0 10.3 120 FTG ---- PE 0.018 10.0 9.1 7.8 0.0 0.174 TL 3.50 PV 0.7 Pipe: 62 -65.1 1.380 PL 4.75 PF 1.418 10.0 9.1 7.8 0.0 14.0 120 FTG ---- PE 0.019 10.0 10.6 8.4 0.0 0.304 TL 4.75 PV 1.3 Pipe: 63 -83.2 1.380 PL 7.00 PF 3.319 10.0 10.6 8.4 0.0 17.9 120 FTG ---- PE 0.020 10.0 13.9 10.6 0.0 0.478 TL 7.00 PV 2.1 Pipe: 64 -103.6 1.380 PL 4.00 PF 7.220 10.0 13.9 10.6 0.0 22.2 120 FTG T PE 0.0M1A 10.0 21.1 20.8 0.0 0.717 TL 10.00 PV 3.3 Pipe: 65 -16.5 1.049 PL 9.75 PF 1.321 10.0 8.7 8.5 0.0 6.1 120 FTG 2E PE 0.022 10.0 10.0 9.6 0.0 0.091 TL 13.75 PV 0.3 Pipe: 66 -34.1 1.380 PL 10.00 PF 0.922 10.0 10.0 9.6 0.0 7.3 120 FTG ---- PE 0.023 10.0 10.9 10.0 0.0 0.092 TL 10.00 PV 0.4 Pipe: 67 -52.4 1.380 PL 7.50 PF 2.723 10.0 10.9 10.0 0.0 11.2 120 FTG T PE 0.0M3 10.0 13.6 11.2 0.0 0.204 TL 13.50 PV 0.9 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9DATE: 6/1/2022HOTEL - LA QUINTA - JCP\004 WORKING\CALCS\POOL BAR CALC.SDFJOB TITLE: POOL BAR CALC (.10/3002)(148 SF MAX)(14.8 GPM MIN)(+100 GPM HOSE) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. PT P2 DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (PSI) (PSI) (GPM) FL/FT (PSI) Pipe: 68 -23.0 1.049 PL 10.00 PF 1.724 10.0 16.9 16.4 0.0 8.5 120 FTG ---- PE 0.025 10.0 18.6 17.9 0.0 0.169 TL 10.00 PV 0.5 Pipe: 69 -46.8 1.380 PL 11.00 PF 2.825 10.0 18.6 17.9 0.0 10.0 120 FTG T PE 0.0M2A 10.0 21.4 20.7 0.0 0.165 TL 17.00 PV 0.7 Pipe: 70 -14.8 1.049 PL 9.00 PF 1.026 10.0 6.9 6.7 0.0 5.5 120 FTG 2E PE 0.027 10.0 7.9 7.6 0.0 0.075 TL 13.00 PV 0.2 Pipe: 71 -30.3 1.380 PL 3.50 PF 0.327 10.0 7.9 7.6 0.0 6.5 120 FTG ---- PE 0.028 10.0 8.2 7.5 0.0 0.074 TL 3.50 PV 0.3 Pipe: 72 -46.0 1.380 PL 3.50 PF 0.628 10.0 8.2 7.5 0.0 9.9 120 FTG ---- PE 0.029 10.0 8.7 7.5 0.0 0.160 TL 3.50 PV 0.7 Pipe: 73 -62.3 1.380 PL 5.75 PF 1.629 10.0 8.7 7.5 0.0 13.4 120 FTG ---- PE 0.030 10.0 10.3 8.3 0.0 0.280 TL 5.75 PV 1.2 Pipe: 74 -79.9 1.380 PL 5.00 PF 4.930 10.0 10.3 8.3 0.0 17.1 120 FTG T PE 0.0M4 10.0 15.2 9.9 0.0 0.444 TL 11.00 PV 2.0 Pipe: 75 -18.0 1.380 PL 12.00 PF 0.331 10.0 10.7 10.6 0.0 3.9 120 FTG ---- PE 0.032 10.0 11.0 10.6 0.0 0.028 TL 12.00 PV 0.1 Pipe: 76 -36.2 1.380 PL 12.00 PF 1.232 10.0 11.0 10.6 0.0 7.8 120 FTG ---- PE 0.033 10.0 12.3 11.3 0.0 0.103 TL 12.00 PV 0.4 Pipe: 77 -55.4 1.380 PL 7.00 PF 2.933 10.0 12.3 11.3 0.0 11.9 120 FTG T PE 0.0M4 10.0 15.2 9.9 0.0 0.225 TL 13.00 PV 0.9 Pipe: 78 -22.6 1.049 PL 11.50 PF 1.934 10.0 16.3 15.9 0.0 8.4 120 FTG ---- PE 0.035 10.0 18.2 17.6 0.0 0.164 TL 11.50 PV 0.5 Pipe: 79 -46.2 1.380 PL 5.50 PF 0.935 10.0 18.2 17.6 0.0 9.9 120 FTG ---- PE 0.036 10.0 19.1 17.6 0.0 0.161 TL 5.50 PV 0.7 Pipe: 80 -70.3 1.380 PL 4.00 PF 3.536 10.0 19.1 17.6 0.0 15.1 120 FTG T PE 0.0M3A 10.0 22.6 22.4 0.0 0.350 TL 10.00 PV 1.5 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10DATE: 6/1/2022HOTEL - LA QUINTA - JCP\004 WORKING\CALCS\POOL BAR CALC.SDFJOB TITLE: POOL BAR CALC (.10/3002)(148 SF MAX)(14.8 GPM MIN)(+100 GPM HOSE) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. PT P2 DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (PSI) (PSI) (GPM) FL/FT (PSI) Pipe: 81 -22.5 1.049 PL 7.75 PF 1.337 10.0 16.6 16.2 0.0 8.4 120 FTG ---- PE 0.038 10.0 17.9 17.3 0.0 0.162 TL 7.75 PV 0.5 Pipe: 82 -45.9 1.380 PL 13.00 PF 2.138 10.0 17.9 17.3 0.0 9.8 120 FTG ---- PE 0.039 10.0 20.0 18.4 0.0 0.159 TL 13.00 PV 0.7 Pipe: 83 -70.5 1.380 PL 0.75 PF 2.439 10.0 20.0 18.4 0.0 15.1 120 FTG T PE 0.0M5 10.0 22.3 21.9 0.0 0.352 TL 6.75 PV 1.5 Pipe: 86 -23.8 1.380 PL 13.00 PF 0.640 10.0 18.6 18.4 0.0 5.1 120 FTG ---- PE 0.041 10.0 19.2 18.5 0.0 0.047 TL 13.00 PV 0.2 Pipe: 87 -47.9 1.380 PL 12.25 PF 3.141 10.0 19.2 18.5 0.0 10.3 120 FTG T PE 0.0M5 10.0 22.3 21.9 0.0 0.172 TL 18.25 PV 0.7 Pipe: 87A -103.6 2.469 PL 6.25 PF 0.3M1A 10.0 21.1 20.8 0.0 6.9 120 FTG ---- PE 0.0M2A 10.0 21.4 20.7 0.0 0.042 TL 6.25 PV 0.3 Pipe: 87B -150.4 2.469 PL 6.00 PF 1.5M2A 10.0 21.4 20.7 0.0 10.1 120 FTG T PE 0.0M4A 10.0 22.9 22.7 0.0 0.084 TL 18.00 PV 0.7 Pipe: 87C -70.3 2.469 PL 2.25 PF 0.3M3A 10.0 22.6 22.4 0.0 4.7 120 FTG T PE 0.0M4A 10.0 22.9 22.7 0.0 0.021 TL 14.25 PV 0.1 Pipe: 87D -220.6 4.260 PL 27.50 PF 0.3M4A 10.0 22.9 22.7 0.0 5.0 120 FTG ---- PE 0.0M6 10.0 23.2 21.3 0.0 0.012 TL 27.50 PV 0.2 Pipe: 88 -101.3 2.469 PL 10.75 PF 0.4M1 10.0 12.4 12.1 0.0 6.8 120 FTG ---- PE 0.0M2 10.0 12.9 11.2 0.0 0.041 TL 10.75 PV 0.3 Pipe: 89 -232.2 2.469 PL 4.00 PF 0.8M2 10.0 12.9 11.2 0.0 15.6 120 FTG ---- PE 0.0M3 10.0 13.6 11.2 0.0 0.188 TL 4.00 PV 1.6 Pipe: 89A -284.6 2.469 PL 5.75 PF 1.6M3 10.0 13.6 11.2 0.0 19.1 120 FTG ---- PE 0.0M4 10.0 15.2 9.9 0.0 0.274 TL 5.75 PV 2.4 Pipe: 90 -420.0 2.469 PL 2.25 PF 8.0M4 10.0 15.2 9.9 0.0 28.1 120 FTG T PE 0.0M6 10.0 23.2 21.3 0.0 0.562 TL 14.25 PV 5.3 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 11DATE: 6/1/2022HOTEL - LA QUINTA - JCP\004 WORKING\CALCS\POOL BAR CALC.SDFJOB TITLE: POOL BAR CALC (.10/3002)(148 SF MAX)(14.8 GPM MIN)(+100 GPM HOSE) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. PT P2 DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (PSI) (PSI) (GPM) FL/FT (PSI) Pipe: 91 -118.4 2.469 PL 4.25 PF 0.9M5 10.0 22.3 21.9 0.0 7.9 120 FTG T PE 0.0M6 10.0 23.2 21.3 0.0 0.054 TL 16.25 PV 0.4 Pipe: 92 -758.9 4.260 PL 47.25 PF 8.6M6 10.0 23.2 21.3 0.0 17.1 120 FTG 2E PE 0.0TOR 10.0 31.9 29.9 0.0 0.118 TL 73.25 PV 2.0 Pipe: 93 -758.9 4.260 PL 9.50 PF 6.4TOR 10.0 31.9 29.9 0.0 17.1 120 FTG CB PE 4.1BOR 0.5 42.4 40.4 0.0 0.118 TL 54.50 PV 2.0 Pipe: 94 -758.9 4.220 PL 3.50 PF 1.9BOR 0.5 42.4 40.4 0.0 17.4 140 FTG E PE 1.5UG5 -3.0 45.8 43.8 0.0 0.093 TL 20.50 PV 2.0 Pipe: 95 -758.9 4.240 PL 173.00 PF 23.6UG5 -3.0 45.8 43.8 0.0 17.2 150 FTG 4ETG PE 0.0UG6 -3.0 69.5 69.4 100.0 0.080 TL 296.00 PV 2.0 Pipe: 96 -858.9 11.650 PL 771.00 PF 0.7UG6 -3.0 69.5 69.4 100.0 2.6 150 FTG 9F PE 0.0UG4 -3.0 70.1 70.1 0.0 0.001 TL 933.00 PV 0.0 Pipe: 97 -858.9 11.650 PL 147.00 PF 0.2UG4 -3.0 70.1 70.1 0.0 2.6 150 FTG TG2F PE 0.0HS1 -3.0 70.3 70.3 0.0 0.001 TL 272.00 PV 0.0 Pipe: 98 -858.9 11.650 PL 260.00 PF 0.2HS1 -3.0 70.3 70.3 0.0 2.6 150 FTG 2F PE 0.0UG2 -3.0 70.6 70.5 0.0 0.001 TL 296.00 PV 0.0 Pipe: 99 -858.9 11.650 PL 71.00 PF 0.1UG2 -3.0 70.6 70.5 0.0 2.6 150 FTG 2E PE -2.6BF1 3.0 68.1 68.1 0.0 0.001 TL 143.00 PV 0.0 Pipe: 100 FIXED PRESSURE LOSS DEVICEBF2 3.0 0.0 71.1 0.0 3.0 psi, 858.9 gpmBF1 3.0 0.0 68.1 0.0 Pipe: 101 -859.0 11.650 PL 66.00 PF 0.1BF2 3.0 71.1 71.1 0.0 2.6 150 FTG TG PE 2.6SRC -3.0 73.8 73.8 (N/A) 0.001 TL 155.00 PV 0.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 12DATE: 6/1/2022HOTEL - LA QUINTA - JCP\004 WORKING\CALCS\POOL BAR CALC.SDFJOB TITLE: POOL BAR CALC (.10/3002)(148 SF MAX)(14.8 GPM MIN)(+100 GPM HOSE) NOTES (HASS): (1) Calculations were performed by the HASS 2021 D computer program in accordance with NFPA13 (2020) under license no. 64622225 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.138 gpm. (3) Velocity pressures have been included in the calculation of the system pressures and flows. Maximum water velocity is 28.1 ft/sec at pipe 90. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node SRC under full flow conditions is 89.85 psi with a flow of 952.96 gpm. (6) PIPE FITTINGS TABLE HASS Pipe Table Name: standard PAGE: A MATERIAL: S40 HWC: 120Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NTee -------------------------------------------------------- F F45Ell 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 2.00 5.00 1.00 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 1.50 2.469 6.00 12.00 4.00 14.00 7.00 1.00 10.00 10.00 12.00 3.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 13DATE: 6/1/2022HOTEL - LA QUINTA - JCP\004 WORKING\CALCS\POOL BAR CALC.SDFJOB TITLE: POOL BAR CALC (.10/3002)(148 SF MAX)(14.8 GPM MIN)(+100 GPM HOSE) PAGE: B MATERIAL: THNWL HWC: 120Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee -------------------------------------------------------- F F45Ell 4.260 13.00 26.00 8.00 29.00 16.00 3.00 26.00 26.00 26.00 6.50 PAGE: D MATERIAL: DIRON HWC: 140Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N F Ell Tee LngEll ChkVlv BfyVlv GatVlv NPTee F45Ell 4.220 17.00 34.00 10.00 37.00 20.00 3.00 34.00 8.50 PAGE: E MATERIAL: PVC150 HWC: 150Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N F Ell Tee LngEll ChkVlv BfyVlv GatVlv NPTee F45Ell 4.240 20.00 39.00 12.00 43.00 23.00 4.00 39.00 10.00 11.650 36.00 81.00 24.00 87.00 28.00 8.00 81.00 18.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 14DATE: 6/1/2022HOTEL - LA QUINTA - JCP\004 WORKING\CALCS\POOL BAR CALC.SDFJOB TITLE: POOL BAR CALC (.10/3002)(148 SF MAX)(14.8 GPM MIN)(+100 GPM HOSE) WATER SUPPLY ANALYSISStatic: 92.60 psi Resid: 72.90 psi Flow: 2760.0 gpm-14.70.020.040.060.080.0100.06009001200150018002100240027003000FLOW (GPM)Note: (1) Dashed Lines indicate extrapolated values from Test Results (2) On Site pressures are based on hose stream deduction at the sourceGAUGE PRESSURE (psi)A12BLEGEND1Available pressure90.33 psi @ 859.0 gpm2Required pressure 73.78 psi @ 859.0 gpmA. Source Supply CurveB. System Demand Curve SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 15DATE: 6/1/2022HOTEL - LA QUINTA - JCP\004 WORKING\CALCS\POOL BAR CALC.SDFJOB TITLE: POOL BAR CALC (.10/3002)(148 SF MAX)(14.8 GPM MIN)(+100 GPM HOSE) WATER SUPPLY CURVE 96+ | *\\\ | 0\\ 88+ \\\ | \\\\ | \\\ | \\\ 80+ \\\\ | \\\ | \\\ | X \\\ 72+ * <-72.9 psi @ 2760 gpm | Flow Test Point | | P 64+ R | E | S | S 56+ U | R | E | 48+ ( | P | S | I 40+ ) | | | 32+ | | | 24+ | | |============================== 16+ LEGEND " | " | X = Required Water Supply " | 73.78 psi @ 859.0 gpm " 8+ " | 0 = Available Water Supply " | 90.33 psi @ 859.0 gpm " | " 0++-+---+----+-----+------+--------+--------+---------+-----------+ 8001200 1600 2000 2400 2800 3200 3600 4000 FLOW (GPM) FP-10.16 page 1 FP-SUB-C3-v01 20210928 The C-3 Coupling is a flexible light weight style which is ideal for fire protection services and other services where low pressure and ambient temperature conditions are expected. For the latest UL/ULC listed, LPCB, VdS and FM Approved pressure ratings versus pipe schedule, see www.asc-es.com or contact your local ASC Engineered Solutions™ Representative. For Listings/Approval Details and Limitations, visit our website at www.asc-es.com or contact an ASC Engineered Solutions™ Sales Representative. Lightweight Flexible Coupling Fig. C-3 SPF/Anvil® Flexible Couplings PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: Material Specifications Housing Ductile Iron conforming to ASTM A536, Grade 65-45-12 Bolts SAE J429, Grade 5, Zinc Electroplated ISO 898-1, Class 8.8, Zinc Electroplated followed by a Yellow Chromate Dip Heavy Hex Nuts ASTM A563, Grade A, Zinc Electroplated ISO 898-2, Class 8.8, Zinc Electroplated followed by a Yellow Chromate Dip Coatings Rust inhibiting paint Color: Orange (Standard) Hot Dipped Zinc Galvanized (Optional) Other available options (Example: RAL3000 or RAL9000 Series) For other coating requirements contact an ASC Engineered Solutions Representative. Lubrication Standard Gruvlok Gruvlok Xtreme required for dry pipe systems and freezer applications Gasket Materials Properties as designated in accordance with ASTM D2000 Pre-Lubricated Grade “E” EPDM, Type A Gasket (Violet color code) -40°F to 150°F (Service Temperature Range) (-40°C to 65°C) Recommended for wet and dry (oil free air) pipe fire protection sprinkler systems. For dry pipe systems and freezer applications, Gruvlok Xtreme Lubricant is required. Gasket Type Standard C Style Flush Gap LPS 1219: Issue 3.1Cert/LPCB ref. 119a/03 asc-es.com Note: Range of Pipe End Separation and Angular Deflection values are for roll grooved pipe and may be doubled for cut groove pipe. 1. Working pressure and/or end load are total allowable, based on standard weight steel pipe, roll or cut grooved. 2. One time field test pressure may be increased to 1.5 times the figures listed above. – Working Pressure Ratings are for reference only and based on Sch. 10 and Sch. 40 pipe. For the latest UL/ULC, FM, VdS and LPCB pressure ratings versus pipe schedule, please visit asc-es.com or contact your local ASC Engineered Solutions™ Representative. § – For additional Bolt Torque information see Technical Data Section. WARNING: For dry pipe systems and freezer applications lubrication of the gasket is required, Gruvlok Xtreme Lubricant is required. FP-10.16 page 2 FP-SUB-C3-v01 20210928 SPF/Anvil® Flexible Couplings Nominal Size Pipe O.D. Max. Working Pressure Max. End Load Range of Pipe End Separation Deflection from CL Coupling Dimensions Coupling Bolts Specified Torque §Approx. Wt. Ea.Per Coupling Pipe X Y Z Qty.Size Min.Max. In./DN(mm)In./mm PSI/bar Lbs./kN In./mm Degrees In./Ft.-mm/m In./mm In./mm In./mm In./mm Ft.-Lbs./N-m Ft.-Lbs./N-m Lbs./kg 1 1.315 300 407 0-1/32 1° 22'0.29 2 1/2 4 1 3/4 2 3/8 x 2 1/4 30 45 1.2 25 33.4 20.7 1.81 0-0.79 23.8 64 102 44 M10 x 57 40 60 0.5 1 1/4 1.660 300 649 0-1/32 1° 5'0.23 2 3/4 4 1/4 1 3/4 2 3/8 x 2 1/4 30 45 1.3 32 42.2 20.7 2.89 0-0.79 18.8 70 111 44 M10 x 50 40 60 0.6 1 1/2 1.900 300 851 0-1/32 0° 57'0.20 3 4 1/2 1 3/4 2 3/8 x 2 1/4 30 45 1.5 40 48.3 20.7 3.78 0-0.79 16.5 76 117 44 M10 x 50 40 60 0.7 2 2.375 300 1,329 0-1/32 0° 45'0.16 3 3/8 5 1 7/8 2 3/8 x 2 1/4 30 45 1.7 50 60.3 20.7 5.91 0-0.79 13.1 66 140 48 M10 x 57 40 60 0.8 2 1/2 2.875 300 1,948 0-1/32 0° 37'0.13 3 7/8 5 1/2 1 7/8 2 3/8 x 2 1/4 30 45 2.0 65 73.0 20.7 8.66 0-0.79 10.9 99 146 48 M10 x 57 40 60 0.9 3 O.D.2.996 300 2,115 0-1/32 0° 36'0.13 4 1/8 5 3/4 1 7/8 2 3/8 x 2 1/4 30 45 1.9 76.1 76.1 20.7 9.41 0-0.79 10.4 105 146 48 M10 x 57 40 60 0.9 3 3.500 300 2,886 0-1/32 0° 31'0.11 4 1/2 6 1/8 1 7/8 2 1/2 x 2 1/2 80 100 2.6 80 88.9 20.7 12.84 0-0.79 8.9 114 156 48 M10 x 63 110 150 1.2 4 4.500 300 4,771 0-3/32 1° 12'0.25 6 1/8 8 2 1/4 2 5/8 x 3 1/2 100 130 4.1 100 114.3 20.7 21.22 0-2.38 20.8 156 203 57 M12 x 70 135 175 1.9 5 1/2 O.D.5.500 300 7,127 0-3/32 0° 59'0.20 6 7/8 9 5/16 2 1/4 2 5/8 x 3 1/2 100 130 5.5 139.7 139.7 20.7 31.70 0-2.38 17.0 175 237 57 M16 x 89 135 175 2.5 5 5.563 300 7,292 0-3/32 0° 58'0.20 7 9 5/16 2 1/4 2 5/8 x 3 1/4 100 130 5.7 125 141.3 20.7 32.44 0-6.4 16.8 178 237 57 M16 x 85 135 175 2.6 6 1/2 O.D.6.500 300 9,955 0-3/32 0° 50'0.17 7 7/8 10 1/2 2 1/4 2 5/8 x 3 1/4 100 130 6.1 165.1 165.1 20.7 44.28 0-2.38 13.1 200 267 57 M16 x 85 135 175 2.8 6 6.625 300 10,341 0-3/32 0° 49'0.17 8 1/4 10 3/4 2 1/4 2 5/8 x 3 1/4 100 130 6.1 150 168.3 20.7 46.00 0-2.38 14.1 210 273 57 M16 x 85 135 175 2.8 8 8.625 300 17,528 0-3/32 0° 37'0.13 10 5/8 13 1/2 2 1/2 2 3/4 x 4 1/4 130 180 11.9 200 219.1 20.7 77.97 0-2.38 10.9 270 343 64 M20 x 110 175 245 5.4 Lightweight Flexible Coupling Fig. C-3 asc-es.com Specified Bolt Torque Specified bolt torque is for the oval neck track bolts used on SPF couplings. The nuts must be tightened alternately and evenly until fully tightened. Caution: Proper torquing of coupling bolts is required to obtain specified performance. Over torquing the bolts may result in damage to the bolt and/or casting which could result in pipe joint separation. Under torquing the bolts may result in lower pressure retention capabilities, lower bend load capabilities, joint leakage and pipe joint separation. Pipe joint separation may result in significant property damage and serious injury. The instructions are based on pipe grooved in accordance with SPF® grooving specifications. Check pipe ends for proper groove dimensions and to assure that the pipe ends are free of indentations and projections which would prevent proper sealing. ALWAYS USE A GRUVLOK® SPF/ANVIL® LUBRICANT FOR PROPER COUPLING ASSEMBLY. Thorough lubrication of the external surface of the gasket is essential to prevent pinching and possible damage to the gasket. For temperatures above 150°F (65˚C) and below 32°F (0˚C) use Gruvlok SPF/Anvil Xtreme Lubricant and lubricate all gasket surfaces, internal and external. See Gruvlok SPF/Anvil Lubricants in the Technical Data section of the Anvil SPF catalog for additional important information. 1 Check and lubricate gasket Check gasket to be sure it is compatible for the intended service. Apply a thin coating of Gruvlok SPF/Anvil Xtreme Lubricant to the outside and sealing lips of the gasket. Be careful that foreign particles do not adhere to lubricated surfaces. 2 Gasket installation Slip the gasket over the pipe end, making sure the gasket lip does not overhang the pipe end. 3 Alignment After aligning the two pipe ends together, pull the gasket into position, centering it between the grooves on each pipe. Gasket should not extend into the groove on either pipe. 4 Housings With one nut unthreaded to the end of the bolt, unthread the other nut completely and swing the coupling housing halves over the gasket, making sure the housing keys engage the grooves. Insert the bolt and turn the nuts finger tight. 5 Tighten nuts Tighten the nuts alternately and equally to the specified bolt torque. The housing bolt pads must make metal-to-metal contact. Caution: Uneven tightening may cause the gasket to pinch. 6 Assembly is complete Visually inspect the pipe joint to assure the coupling keys are fully engaged in the pipe grooves and the bolt pads are in firm even metal-to-metal contact on both sides of the coupling. Flexible Couplings / Installation Fig. C-3 Lightweight Flexible Coupling FP-10.16 page 3 FP-SUB-C3-v01 20210928 1 2 3 4 5 Specified Bolt Torque Bolt Size Wrench Size Specified Bolt Torque* In./mm In./mm Ft.-Lbs/N-m 3/8 11/16 30-45 M10 16 40-60 1/2 7/8 80-100 M12 22 110-150 5/8 1 1/16 100-130 M16 24 135-175 3/4 1 1/4 130-180 M20 30 175-245 7/8 1 7/16 180-220 M22 34 245-300 * Non-lubricated bolt torque 6 INTRODUCTION www.anvilintl.com16 GRUVLOK® COUPLINGS FOR GROOVED-END PIPE Gruvlok couplings for grooved-end pipe are available in nominal pipe sizes 1" thru 30" and metric sizes. The variety of coupling designs provide a universal means for the connection of pipe, fittings and pipe system components. The wide assortment of Gruvlok couplings and gaskets permit selection of the most suitable combination for a specific application, thus providing the most versatile and economical pipe system installation. MATERIAL SPECIFICATIONS ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B, or J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts are zinc electroplated followed by a yellow chromate dip. STAINLESS STEEL BOLTS & NUTS: Stainless steel bolts and nuts are available for the Fig. 7001, 7401, 7401-2, 7001-2, 7004, 7000 and 7400 couplings in standard 304SS, (316SS available as special order) HOUSING: Ductile Iron conforming to ASTM A 536, Grade 65-45-12 COATINGS: Rust inhibiting paint Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. GASKETS: Materials Properties as designated in accordance with ASTM D 2000 GRADE “EP” EPDM (Green/Red color code) NSF-61 Certified -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. GRADE “E” EPDM (Green color code) NSF-61 Certified -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. Air with oil vapors and vegetable and mineral oils. NOT FOR USE IN HOT WATER OR HOT AIR Grade “O” Fluoro-Elastomer (Blue color code) Size Range: 1" - 12" (C style only) 20°F to 300°F (Service Temperature Range)(-29°C to 149°C) Recommended for high temperature resistance to oxidizing acids, petroleum oils, hydraulic fluids, halogenated hydrocarbons and lubricants Grade “L” Silicone (Red color code) Size Range: 1" - 12" (C style only) -40°F to 350°F (Service Temperature Range)(-40°C to 177°C) Recommended for dry, hot air and some high temperature chemical services GASKET TYPE: Standard C Style Flush Gap: 1" - 24" End Guard: 1" - 12" (Fig. 7004 and 7377) SlideLOK: 2" - 8" LUBRICATION: Standard Gruvlok Gruvlok XtremeTM (Do Not use with Grade “L”) WORKING PRESSURE, END LOAD, PIPE END SEPARATION & DEFLECTION FROM CENTER LINE: Based on standard wall steel pipe with cut or roll grooves in accordance with Gruvlok specifications. See technical data section for design factors. GL-3.14 INTRODUCTION www.anvilintl.com 17 IntroductionCouplingsOutletsFittingsValves & AccessoriesHighPressureDi-ElectricNipplesPlain-EndFittingsHDPECouplingsSock-It®FittingsStainlessSteel MethodRoll GrooversInstallation& AssemblySpecialCoatingsDesignServicesTechnicalDataMaster Format3 Part Specs.PictorialIndexCTS Copper SystemGruvlok Couplings are identified by either the nominal ANSI pipe size in inches or pipe O.D. in millimeters (see column 2). Nominal Outside Diameter of Pipe. Maximum line pressure, including surge, to which a joint can be subjected. Working pressure ratings are based on standard wall steel pipe with standard cut or roll grooves in accordance with Gruvlok specifications. For Performance Data on other than standard wall pipe, refer to Technical data section. NOTE: For one time field test only, the maximum joint working pressure may be increased to 1.5 times the figure shown unless otherwise noted. Maximum end load from all interior and/or exterior forces to which the joint can be subjected are based on standard wall steel pipe with standard cut or roll grooves in accordance with Gruvlok specifications. Range of pipe end separation for roll grooved pipe, Double values shown when using cut groove pipe; see page 204 for details. Maximum allowable angular deflection values from centerline when using standard roll grooved pipe; Double values shown when using cut groove pipe; see page 204 for details. “X”, “Y”, and “Z” are external dimensions for reference purposes only. The quantity of bolts per coupling. Nuts must be tightened alternating and evenly to the specified bolt torque. See individual product installation instructions for additional important information. Approximate weight for a fully assembled coupling with gasket, bolts, and nuts. COUPLING DATA CHART NOTES COUPLING DATA CHART NOTES Nominal Size O.D.Max. Work. Pressure Max. End Load Range of Pipe End Separation Deflection from CL Coupling Dimensions Coupling Bolts Specified Torque Approx. Wt. Ea.Per Coupling of Pipe X Y Z Qty. Size Min. Max. In./DN(mm) In./mm PSI/bar Lbs./kN In./mm Degrees(˚)-Minutes(')In./ft-mm/m In./mm In./mm In./mm In./mm Ft.-Lbs/N-m Lbs./kg 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 GL-8.14 COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com18 For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FIG. 7401 Rigidlok® Coupling MATERIAL SPECIFICATIONS ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B, or J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts are zinc electroplated followed by a yellow chromate dip. STAINLESS STEEL BOLTS & NUTS: 304SS Stainless Steel bolts and nuts are available as a standard option. (316SS are available for special order). HOUSING: Ductile Iron conforming to ASTM A 536, Grade 65-45-12 COATINGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. GASKETS: Materials Properties as designated in accordance with ASTM D 2000 Grade “EP” EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended. NSF-61 Certified for cold and hot water applications up through 12". Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. air with oil vapors and vegetable and mineral oils. NOT FOR USE IN HOT WATER OR HOT AIR Grade “O” Fluoro-Elastomer (Blue color code) Size Range: 1" - 12" (C style only) 20°F to 300°F (Service Temperature Range)(-29°C to 149°C) Recommended for high temperature resistance to oxidizing acids, petroleum oils, hydraulic fluids, halogenated hydrocarbons and lubricants. Grade “L” Silicone (Red color code) Size Range: 1" - 12" (C style only) -40°F to 350°F (Service Temperature Range)(-40°C to 177°C) Recommended for dry, hot air and some high temperature chemical services. Contact an Anvil Representative for availability. GASKET TYPE: C Style (1" - 24") Flush Gap (1" - 24") LUBRICATION: Standard Gruvlok XtremeTM (Do Not use with Grade “L”) The Fig. 7401 Rigidlok Coupling from Gruvlok provides a rigid pipe connection. Rigidity is attained simply; it is designed in. The Fig. 7401 Rigidlok coupling utilizes a technologically advanced housing design that conforms to and grips the pipe. With the Fig. 7401 there emerges a new generation of rigid couplings. Coupling installation is fast and easy, remove only one nut and swing the housing over the gasket and into the grooves. The exclusive Guidelok® feature automatically separates the grooved pipe ends and guides the coupling into position as the bolts are tightened. Precisely sized and oriented tines in the housing key section firmly grip the pipe. The combination of these designed in features produce a secure, rigid pipe joint connection. This coupling is an ideal connector for service and applications that require a rigid connection. The Fig. 7401 Rigidlok Coupling is designed for use with roll grooved or cut grooved standard weight and roll grooved lightweight pipe, as well as with grooved-end fittings and valves. The Rigidlok Coupling maintains a rigid connection with support and hanging in conformance with applicable ANSI B31.1 Power Piping Code, ANSI B31.9 Building Service Pipe Code as well as NFPA 13 sprinkler systems. The Fig. 7401 Rigidlok Coupling allows for working pressure ratings to 750 psi (51.7 bar) when used on standard wall roll or cut grooved pipe. GL-3.14 COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com 19 IntroductionCouplingsOutletsFittingsValves & AccessoriesHighPressureDi-ElectricNipplesPlain-EndFittingsHDPECouplingsSock-It®FittingsStainlessSteel MethodRoll GrooversInstallation& AssemblySpecialCoatingsDesignServicesTechnicalDataMaster Format3 Part Specs.PictorialIndexCTS Copper SystemSIZES 1 1/2" - 14"SIZE 16"SIZES 18" - 24" FIG. 7401 Rigidlok® Coupling FIGURE 7401 RIGIDLOK COUPLING Nominal Size O.D.Max. Working Pressure Max. End Load Range of Pipe End Separation Coupling Dimensions Coupling Bolts*Specified Torque §Approx. Wt. Ea.X Y Z Qty. Size Min. Max. In./DN(mm) In./mm PSI/bar Lbs./kN In./mm In./mm In./mm In./mm In./mm Ft.-Lbs/N-M Lbs./kg 11⁄2 1.900 750 2,126 0- 1⁄32 3 5 1⁄8 17⁄8 2 3⁄8 x 21⁄4 30 45 1.8 40 48.3 51.7 9.46 0-0.79 76 130 48 M10 x 57 40 60 0.8 2 2.375 750 3,323 0- 1⁄32 31⁄2 55⁄8 17⁄8 2 3⁄8 x 21⁄2 30 45 2.4 50 60.3 51.7 14.78 0-0.79 89 143 48 M10 x 63 40 60 1.1 21⁄2 2.875 750 4,869 0- 1⁄32 4 6 1⁄8 17⁄8 2 3⁄8 x 21⁄2 30 45 2.9 65 73.0 51.7 21.66 0-0.79 102 156 48 M10 x 63 40 60 1.3 3 O.D. 2.996 750 5,207 0- 1⁄32 41⁄8 61⁄8 17⁄8 2 3⁄8 x 21⁄2 80 100 3.4 76.1 76.1 51.7 23.52 0-0.79 105 156 48 M10 x 63 110 150 1.5 3 3.500 750 7,216 0- 1⁄32 43⁄4 71⁄4 17⁄8 2 1⁄2 x 3 80 100 3.6 80 88.9 51.7 32.10 0-0.79 121 184 48 M12 x 76 110 150 1.6 4 4.500 750 11,928 0- 3⁄32 57⁄8 83⁄8 21⁄8 2 1⁄2 x 3 80 100 5.0 100 114.3 51.7 53.06 0-2.38 149 213 54 M12 x 76 110 150 2.3 51⁄2 O.D. 5.500 750 17,819 0-3⁄32 7 9 3⁄4 21⁄8 2 5⁄8 x 31⁄2 100 130 6.9 139.7 139.7 51.7 79.26 0-2.38 178 248 54 M16 x 85 135 175 3.1 5 5.563 750 18,229 0- 3⁄32 7 10 2 1⁄8 2 5⁄8 x 31⁄2 100 130 6.9 125 141.3 51.7 81.09 0-2.38 178 254 54 M16 x 85 135 175 3.1 61⁄2 O.D. 6.500 750 24,887 0- 3⁄32 8 11 2 1⁄8 2 5⁄8 x 31⁄2 100 130 7.6 165.1 165.1 51.7 110.70 0-2.38 203 279 54 M16 x 85 135 175 3.4 6 6.625 750 25,854 0- 3⁄32 81⁄8 111⁄8 21⁄8 2 5⁄8 x 31⁄2 100 130 7.9 150 168.3 51.7 115.00 0-2.38 206 283 54 M16 x 85 135 175 3.6 8 8.625 600 35,056 0- 3⁄32 101⁄2 141⁄8 25⁄8 2 3⁄4 x 41⁄2 130 180 15.9 200 219.1 41.4 155.94 0-2.38 267 359 67 M20 x 110 175 245 7.2 10 10.750 500 45,381 0- 3⁄32 127⁄8 171⁄2 25⁄8 2 1 x 6 200 250 25.6 250 273.1 34.5 201.87 0-2.38 327 445 67 M24 x 150 270 340 11.6 12 12.750 400 51,070 0- 3⁄32 15 19 1⁄2 25⁄8 2 7⁄8 x 6 180 220 30.5 300 323.9 27.6 227.17 0-2.38 381 495 67 M22 x 150 245 300 13.8 14 14.000 300 46,181 0- 3⁄32 161⁄4 193⁄4 3 2 7⁄8 x 51⁄2 180 220 36.1 350 355.6 20.7 205.43 0-2.38 413 502 76 M22 x 140 245 300 16.4 16 16.000 300 60,319 0- 3⁄32 181⁄8 221⁄4 3 3 7⁄8 x 51⁄2 180 220 42.0 400 406.4 20.7 268.31 0-2.38 460 565 76 M22 x 140 245 300 19.1 18 18.000 300 76,341 0- 3⁄32 201⁄2 243⁄8 31⁄8 4 1 x 4 200 250 51.6 450 457.2 20.7 339.58 0-2.38 521 619 79 M24 x 100 270 340 23.4 20 20.000 300 94,248 0- 3⁄32 23 26 7⁄8 31⁄8 4 1 x 4 200 250 68.3 500 508.0 20.7 419.23 0-2.38 581 683 79 M24 x 100 270 340 31.0 24 24.000 250 113,097 0- 3⁄32 271⁄8 307⁄8 31⁄8 4 1 x 4 200 250 89.3 600 609.6 17.2 503.08 0-2.38 689 784 79 M24 x 100 270 340 40.5 Y Z XY Z X Y Z X GL-7.12 For additional details see “Coupling Data Chart Notes” on page 17. * Available in ANSI or metric bolt sizes only as indicated. § – For additional Bolt Torque information, see page 204. See Installation & Assembly directions on page 163. Not for use in copper systems. NOTE: Range of Pipe End Seperation values are for roll grooved pipe and may be doubled for cut groove pipe. COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com20 FIG. 7401-2 Rigidlok® Coupling GL-3.14 FIGURE 7401-2 RIGIDLOK COUPLING Nominal Size O.D. Max. Working Pressure Max. End Load Range of Pipe End Separation Coupling Dimensions Coupling Bolts*Specified Torque §Approx. Wt. Ea.X Y Z Qty. Size Min. Max. In./DN(mm) In./mm PSI/bar Lbs./kN In./mm In./mm In./mm In./mm In./mm Ft.-Lbs/N-M Lbs./kg 14 14.000 350 53,878 0- 3⁄32 161⁄4 193⁄4 3 2 7⁄8 x 51⁄2 180 220 36.5 350 355.6 24.1 239.66 0-2.38 413 502 76 – 245 300 16.6 16 16.000 350 70,372 0- 3⁄32 185⁄16 22 3 2 1 x 5 1⁄2 250 300 46.0 400 406.4 24.1 313.03 0-2.38 465 558 76 – 340 408 20.9 18 18.000 350 89,064 0- 3⁄32 203⁄4 241⁄4 31⁄8 2 1 x 5 1⁄2 250 300 62.5 450 457.2 24.1 396.18 0-2.38 527 615 79 – 340 408 28.3 20 20.000 350 109,956 0- 3⁄32 23 27 1⁄8 31⁄8 2 1 1⁄8 x 51⁄2 375 425 73.5 500 508.0 24.1 489.11 0-2.38 582 691 79 – 510 578 33.3 24 24.000 350 158,336 0- 3⁄32 271⁄4 311⁄8 33⁄16 2 1 1⁄8 x 51⁄2 375 425 90.5 600 609.6 24.1 704.31 0-2.38 688 791 81 – 510 578 41.1 Range of Pipe End Separation values are for roll grooved pipe and may be doubled for cut groove pipe. See Installation & Assembly directions on page 167. Z XY Gruvlok® introduces new 2-piece large diameter standard groove couplings in both rigid and flexible styles • Uses standard grooves (conforming to AWWA C-606) • No special grooves or grooving tools needed • Pressures to 350 P.S.I. on cut or roll grooved pipe with a wall thickness of 0.250" or greater • No special fittings needed • No special valves needed • Up to 23% less weight than competitive models • Sizes: 14" through 24" in Rigid: Figure 7401-2 MATERIAL SPECIFICATIONS ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B, or J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. STAINLESS STEEL BOLTS & NUTS: 304SS Stainless Steel bolts and nuts are available as a standard option. (316SS are available for special order). HOUSING: Ductile Iron conforming to ASTM A 536, Grade 65-45-12 COATINGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. GASKETS: Materials Properties as designated in accordance with ASTM D 2000 Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. Air with oil vapors and vegetable and mineral oils. NOT FOR USE IN HOT WATER OR HOT AIR GASKET TYPE: Flush Gap (Standard) LUBRICATION: Standard Gruvlok XtremeTM WORKING PRESSURE, END LOAD & PIPE END SEPARATION: Based on standard wall steel pipe with cut or roll grooves in accordance with Gruvlok specifications. See technical data section for design factors. COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com 21 IntroductionCouplingsOutletsFittingsValves & AccessoriesHighPressureDi-ElectricNipplesPlain-EndFittingsHDPECouplingsSock-It®FittingsStainlessSteel MethodRoll GrooversInstallation& AssemblySpecialCoatingsDesignServicesTechnicalDataMaster Format3 Part Specs.PictorialIndexCTS Copper SystemThe SlideLOK coupling is a ready for installation coupling designed to reduce installation time. The slide action allows for greater flexibility during installation. The patented gasket provides four separate sealing surfaces for added protection. The engineered metal-to-metal installation requirement is a quick and easy indication of proper assembly. The SlideLOK is designed to be used with roll groove or cut groove steel pipe, as well as with grooved light wall pipe, Gruvlok® grooved-end fittings, and valves. The SlideLOK coupling produces a secure, rigid pipe joint connection. The SlideLOK coupling allows for a maximum working pressure of 750 psi on roll or cut grooved standard wall pipe. Contact an Anvil representative for light wall pipe pressure ratings. FIG. 7402 SlideLOK™ Ready for Installation Coupling MATERIAL SPECIFICATIONS ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B, or J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. HOUSING: Ductile Iron conforming to ASTM A 536, Grade 65-45-12 COATINGS: Rust inhibiting paint Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) GASKETS: Materials Properties as designated in accordance with ASTM D 2000 Grade “EP” EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. air with oil vapors and vegetable and mineral oils. NOT FOR USE IN HOT WATER OR HOT AIR GASKET TYPE: SlideLOK (2" - 8") LUBRICATION: Standard Gruvlok XtremeTM SlideLOK Pressure Responsive Gasket GL-3.14 Patent D680629, D680630, D696751 COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com22 ZY Xa FIGURE 7402 SLIDELOK COUPLING Nominal Size O.D.Max. Working Pressure Max. End Load Range of Pipe End Separation Coupling Dimensions Coupling Bolts Specified Torque §Approx. Wt. Ea.Xa Xb Y Z Qty. Size Min. Max. In./DN(mm) In./mm PSI/bar Lbs./kN In./mm In./mm In./mm In./mm In./mm In./mm Ft.-Lbs/N-M Lbs./kg 2 2.375 750 3,323 0- 1⁄32 33⁄4 33⁄8 6 2 2 1⁄2 x 23⁄4 80 100 2.9 50 60.3 51.7 14.78 0-0.79 95 86 152 51 M12 x 70 110 150 1.3 21⁄2 2.875 750 4,869 0- 1⁄32 45⁄8 41⁄4 63⁄8 2 2 1⁄2 x 23⁄4 80 100 3.1 65 73.0 51.7 21.66 0-0.79 117 108 163 51 M12 x 70 110 150 1.4 3 3.500 750 7,216 0- 1⁄32 51⁄5 411⁄16 7 2 2 1⁄2 x 31⁄2 80 100 3.6 80 88.9 51.7 32.10 0-0.79 132 119 178 51 M12 x 89 110 150 1.6 4 4.500 750 11,928 0- 3⁄32 61⁄2 6 8 5⁄16 2 2 1⁄2 x 31⁄2 80 100 4.9 100 114.3 51.7 53.06 0-2.38 165 152 212 51 M12 x 89 110 150 2.2 5 5.563 750 18,229 0- 3⁄32 73⁄4 71⁄8 93⁄4 2 2 5⁄8 x 31⁄2 100 130 6.1 125 141.3 51.7 81.09 0-2.38 196 181 248 51 M16 x 89 135 175 2.8 6 6.625 700 24,130 0- 3⁄32 87⁄8 81⁄5 104⁄5 2 2 5⁄8 x 31⁄2 100 130 6.8 150 168.3 48.3 107.34 0-2.38 224 208 274 51 M16 x 89 135 175 3.1 8 8.625 600 35,056 0- 3⁄32 113⁄8 105⁄8 132⁄5 21⁄2 2 3⁄4 x 41⁄2 130 180 10.9 200 219.1 41.4 155.94 0-2.38 289 270 340 64 M20 x 115 175 245 4.9 For additional details see “Coupling Data Chart Notes” on page 17. § – For additional Bolt Torque information, see page 204. See Installation & Assembly directions on pages 164-165. Not for use in copper systems. NOTES: Range of Pipe End Separation values are for roll grooved pipe and may be doubled for cut groove pipe. Impact gun can be used for installation, verify that the output of the impact gun is within the required torque range. Not for use on "EG" rolled or cut grooved pipe ends. Contact an Anvil Representative for use on light wall and SS pipe applications. FIG. 7402 SlideLOK™ Ready for Installation Coupling ZY Xb GL-Rev COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com 23 IntroductionCouplingsOutletsFittingsValves & AccessoriesHighPressureDi-ElectricNipplesPlain-EndFittingsHDPECouplingsSock-It®FittingsStainlessSteel MethodRoll GrooversInstallation& AssemblySpecialCoatingsDesignServicesTechnicalDataMaster Format3 Part Specs.PictorialIndexCTS Copper SystemThe Gruvlok® Fig. 7001 Coupling forms a flexible grooved end pipe joint connection with the versatility for a wide range of applications. Services include mechanical and plumbing, process piping, mining and oil field piping, and many others. The coupling design supplies optimum strength for working pressures to 1000 PSl (69 bar) without excessive casting weight. The flexible design eases pipe and equipment installation while providing the designed-in benefit of reducing pipeline noise and vibration transmission without the addition of special components. To ease coupling handling and assembly and to assure consistent quality, sizes 1" through 14" couplings have two 180° segment housings, 16" have three 120˚ segment housings, and 18" through 24" sizes have four 90° segment housings, while the 28" O.D. and 30" O.D. couplings have six 60° segment housings. The 28" O.D. and 30" O.D. are weld-ring couplings. For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FIG. 7001 Flexible Coupling MATERIAL SPECIFICATIONS ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B, or J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts are zinc electroplated followed by a yellow chromate dip. STAINLESS STEEL BOLTS & NUTS: 304SS Stainless Steel bolts and nuts are available as a standard option. (316SS are available for special order). HOUSING: Ductile Iron conforming to ASTM A 536, Grade 65-45-12 COATINGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. GASKETS: Materials Properties as designated in accordance with ASTM D 2000 Grade “EP” EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended. NSF-61 Certified for cold and hot water applications up through 12". Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. Air with oil vapors and vegetable and mineral oils. NOT FOR USE IN HOT WATER OR HOT AIR Fig. 7001 with Flush Gap Gasket Fig. 7001 with Standard Gasket Grade “O” Fluoro-Elastomer (Blue color code) Size Range: 1" - 12" (C style only) 20°F to 300°F (Service Temperature Range)(-29°C to 149°C) Recommended for high temperature resistance to oxidizing acids, petroleum oils, hydraulic fluids, halogenated hydrocarbons and lubricants. Grade “L” Silicone (Red color code) Size Range: 1" - 12" (C style only) -40°F to 350°F (Service Temperature Range)(-40°C to 177°C) Recommended for dry, hot air and some high temperature chemical services. Contact an Anvil Representative for availability. GASKET TYPE: C Style (1" - 30") Flush Gap (1" - 24") LUBRICATION: Standard Gruvlok XtremeTM (Do Not use with Grade “L”) WORKING PRESSURE, END LOAD, PIPE END SEPARATION & DEFLECTION FROM CENTER LINE: Based on standard wall steel pipe with cut or roll grooves in accordance with Gruvlok specifications. See technical data section for design factors. GL-3.14 COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com24 FIG. 7001 Flexible Coupling SIZES 1" - 14"SIZES 16" - 24"SIZES 28" - 30" FIGURE 7001 FLEXIBLE COUPLING Nominal Size O.D.Max. Work. Pressure Max. End Load Range of Pipe End Separation Deflection from CL Coupling Dimensions Bolt Dimensions*Specified Torque §Approx. Wt. Ea.Per Coupling of Pipe X Y Z Qty. Size Min. Max. In./DN(mm) In./mm PSI/bar Lbs./kN In./mm Degrees(˚)-Minutes(')In./ft-mm/m In./mm In./mm In./mm In./mm Ft.-Lbs/N-m Lbs./kg 1 1.315 1000 1,358 0- 1⁄32 1° 22' 0.29 2 1⁄2 41⁄2 17⁄8 2 3⁄8 x 21⁄4 30 45 1.3 25 33.4 68.9 6.04 0-0.79 23.8 64 114 48 M10 x 57 40 60 0.6 11⁄4 1.660 1000 2,164 0- 1⁄32 1° 5' 0.23 2 3⁄4 41⁄2 17⁄8 2 3⁄8 x 21⁄4 30 45 1.4 32 42.2 68.9 9.63 0-0.79 18.8 70 114 48 M10 x 57 40 60 0.6 11⁄2 1.900 1000 2,835 0- 1⁄32 0° 57' 0.20 3 4 5⁄8 17⁄8 2 3⁄8 x 21⁄4 30 45 1.5 40 48.3 68.9 12.61 0-0.79 16.5 76 117 48 M10 x 57 40 60 0.7 2 2.375 1000 4,430 0- 1⁄32 0° 45' 0.16 3 5⁄8 61⁄8 17⁄8 2 1⁄2 x 3 80 100 3.1 50 60.3 68.9 19.71 0-0.79 13.1 92 156 48 M12 x 76 110 150 1.4 21⁄2 2.875 1000 6,492 0- 1⁄32 0° 37' 0.13 4 1⁄4 61⁄2 17⁄8 2 1⁄2 x 3 80 100 3.7 65 73.0 68.9 28.88 0-0.79 10.9 108 165 48 M12 x 76 110 150 1.7 3 O.D. 2.996 1000 7,050 0- 1⁄32 0° 36' 0.13 4 1⁄4 63⁄4 17⁄8 2 1⁄2 x 3 80 100 4.3 76.1 76.1 68.9 31.36 0-0.79 10.4 108 171 48 M12 x 76 110 150 2.0 3 3.500 1000 9,621 0- 1⁄32 0° 31' 0.11 4 7⁄8 71⁄8 17⁄8 2 1⁄2 x 3 80 100 4.3 80 88.9 68.9 42.80 0-0.79 8.9 124 181 48 M12 x 76 110 150 2.0 31⁄2 4.000 1000 12,566 0- 1⁄32 0° 27' 0.09 5 1⁄4 81⁄4 17⁄8 2 5⁄8 x 31⁄2 100 130 5.1 90 101.6 68.9 55.90 0-0.79 7.8 133 210 48 M16 x 89 135 175 2.3 4 4.500 1000 15,904 0- 3⁄32 1° 12' 0.25 6 1⁄4 83⁄4 2 2 5⁄8 x 31⁄2 100 130 6.8 100 114.3 68.9 70.75 0-2.38 20.8 159 222 51 M16 x 89 135 175 3.1 5 5.563 1000 24,306 0- 3⁄32 0° 58' 0.20 7 1⁄4 111⁄4 2 2 3⁄4 x 41⁄2 130 180 9.6 125 141.3 68.9 108.12 0-2.38 16.8 184 286 51 M20 x 110 175 245 4.4 61⁄2 O.D. 6.500 1000 33,183 0- 3⁄32 0° 50' 0.17 8 1⁄4 113⁄4 2 2 3⁄4 x 41⁄2 130 180 11.8 165.1 165.1 68.9 147.61 0-2.38 14.4 210 298 51 M20 x 110 175 245 5.4 6 6.625 1000 34,472 0- 3⁄32 0° 49' 0.17 8 5⁄8 113⁄4 2 2 3⁄4 x 41⁄2 130 180 11.8 150 168.3 68.9 153.34 0-2.38 14.1 219 298 51 M20 x 110 175 245 5.4 8 8.625 800 46,741 0- 3⁄32 0° 37' 0.13 11 14 3⁄8 23⁄8 2 7⁄8 x 51⁄2 180 220 21.7 200 219.1 55.2 207.91 0-2.38 10.9 279 365 60 M22 x 140 245 300 9.8 10 10.750 800 72,610 0- 3⁄32 0° 30' 0.11 13 1⁄8 165⁄8 25⁄8 2 7⁄8 x 51⁄2 180 220 27.0 250 273.0 55.2 322.99 0-2.38 8.7 333 422 67 M22 x 140 245 300 12.2 12 12.750 800 102,141 0- 3⁄32 0° 25' 0.09 15 1⁄2 185⁄8 25⁄8 2 7⁄8 x 6 180 220 35.0 300 323.9 55.2 454.35 0-2.38 7.3 394 473 67 M22 x 150 245 300 15.9 14 14.000 300 46,181 0- 3⁄32 0° 23' 0.08 16 1⁄8 201⁄2 3 2 7⁄8 x 51⁄2 180 220 37.0 350 355.6 20.7 205.43 0-2.38 6.7 410 521 76 M22 x 140 245 300 16.8 16 16.000 300 60,319 0- 3⁄32 0° 20' 0.07 18 1⁄8 227⁄8 3 4 1 x 4 200 250 50.0 400 406.4 20.7 268.31 0-2.38 5.9 460 581 76 *- - 22.7 18 18.000 300 76,341 0- 3⁄32 0° 18' 0.06 21 1⁄8 253⁄8 31⁄8 4 1 x 4 200 250 72.0 450 457.2 20.7 339.58 0-2.38 5.2 537 645 79 *- - 32.7 20 20.000 300 94,248 0- 3⁄32 0° 16' 0.06 23 28 1⁄4 31⁄8 4 1 1⁄8 x 41⁄2 225 275 82.0 500 508.0 20.7 419.23 0-2.38 4.7 584 718 79 *- - 37.2 24 24.000 300 135,717 0- 3⁄32 0° 13' 0.05 27 32 3⁄8 31⁄8 4 1 1⁄8 x 41⁄2 225 275 90.0 600 609.6 20.7 603.70 0-2.38 3.9 686 822 79 *- - 40.8 28" O.D. 28.875 150 98,226 0- 3⁄32 0° 11' 0.04 33 1⁄2 351⁄2 31⁄8 6 1 x 5 1⁄2 200 250 105.0 733.4 733.4 10.3 436.93 0-2.38 3.2 851 902 79 *- - 47.6 30" I.D. 31.00 150 113,215 0- 3⁄32 0° 10' 0.04 33 3⁄4 381⁄4 35⁄8 6 1 x 5 1⁄2 200 250 137.0 787.4 787.4 10.3 503.61 0-2.38 3.0 857 972 92 *- - 62.1 Y X Z Y X Z Y X Z * Available in ANSI or metric bolt sizes only as indicated. For additional details see “Coupling Data Chart Notes” on page 17. § – For additional Bolt Torque information, see page 204. See Installation & Assembly directions on page 166. Not for use in copper systems. NOTES: Range of Pipe End Separation and Angular Deflection values are for roll grooved pipe and may be doubled for cut groove pipe. See page 204 for details. Refer to page 210 for Misalignment & Deflection Calculations and page 211 for Curve Layout Calculations. GL-3.14 COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com 25 IntroductionCouplingsOutletsFittingsValves & AccessoriesHighPressureDi-ElectricNipplesPlain-EndFittingsHDPECouplingsSock-It®FittingsStainlessSteel MethodRoll GrooversInstallation& AssemblySpecialCoatingsDesignServicesTechnicalDataMaster Format3 Part Specs.PictorialIndexCTS Copper SystemFIG. 7001-2 Flexible Coupling GL-3.14 FIGURE 7001-2 FLEXIBLE COUPLING Nominal Size O.D. Max. Work. Pressure Max. End Load Range of Pipe End Separation Deflection from CL Coupling Dimensions Bolt Dimensions* Specified Torque §Approx. Wt. Ea.Per Coupling of Pipe X Y Z Qty. Size Min. Max. In./DN(mm)In./mm PSI/bar Lbs./kN In./mm Degrees(˚)-Minutes(')In./ft-mm/m In./mm In./mm In./mm In./mm Ft.-Lbs/N-m Lbs./kg 14 14.000 350 53,878 0- 3⁄32 0° 23' 0.08 16 1⁄4 193⁄4 3 2 7⁄8 x 51⁄2 180 220 36.0 350 355.6 24.1 239.66 0-2.38 6.7 413 502 76 – 245 300 16.3 16 16.000 350 70,372 0- 3⁄32 0° 20' 0.07 18 5⁄16 22 3 2 1 x 5 1⁄2 250 300 45.0 400 406.4 24.1 313.03 0-2.38 5.9 465 558 76 – 340 408 20.4 18 18.000 350 89,064 0- 3⁄32 0° 18' 0.06 20 3⁄4 241⁄4 31⁄8 2 1 x 5 1⁄2 250 300 60.0 450 457.2 24.1 396.18 0-2.38 5.2 527 615 79 – 340 408 27.2 20 20.000 350 109,956 0-3⁄32 0° 16' 0.06 23 27 1⁄8 31⁄8 2 1 1⁄8 x 51⁄2 375 425 72.5 500 508.0 24.1 489.11 0-2.38 4.7 582 691 79 – 510 578 32.9 24 24.000 350 158,336 0-3⁄32 0° 13' 0.05 27 1⁄4 311⁄8 33⁄16 2 1 1⁄8 x 51⁄2 375 425 90.0 600 609.6 24.1 704.31 0-2.38 3.9 688 791 81 – 510 578 40.8 Range of Pipe End Separation and Angular Deflection values are for roll grooved pipe and may be doubled for cut groove pipe. See Installation & Assembly directions on page 167. MATERIAL SPECIFICATIONS ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B, or J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. STAINLESS STEEL BOLTS & NUTS: 304SS Stainless Steel bolts and nuts are available as a standard option. (316SS are available for special order). HOUSING: Ductile Iron conforming to ASTM A 536, Grade 65-45-12 COATINGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. GASKETS: Materials Properties as designated in accordance with ASTM D 2000 Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. Air with oil vapors and vegetable and mineral oils. NOT FOR USE IN HOT WATER OR HOT AIR GASKET TYPE: Flush Gap (14" - 24") LUBRICATION: Standard Gruvlok XtremeTM WORKING PRESSURE, END LOAD, PIPE END SEPARATION & DEFLECTION FROM CENTER LINE: Based on standard wall steel pipe with cut or roll grooves in accordance with Gruvlok specifications. See technical data section for design factors. Z XY Gruvlok® introduces new 2-piece large diameter standard groove couplings in both rigid and flexible styles • Uses standard grooves (conforming to AWWA C-606) • No special grooves or grooving tools needed • Pressures to 350 P.S.I. on cut or roll grooved pipe with a wall thickness of 0.250" or greater • No special fittings needed • No special valves needed • Up to 23% less weight than competitive models • Sizes: 14" through 24" in Flexible: Figure 7001-2 COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com26 FIG. 7011 Standard Coupling The Gruvlok® Figure 7011 Standard Coupling is a flexible coupling designed to join roll grooved or cut grooved 30" O.D. pipe for a wide range of applications, including Commercial/Industrial Construction, Mining, Process Piping and many others. This coupling’s operating temperature ranges from –40°F to 230°F (-40°C to 110°C) with the Grade E EPDM gasket and –20°F to 180°F (-29°C to 82°C) with the Grade T Nitrile gasket. The operating pressure ranges 15" of Hg. vacuum to 300 psig on standard wall steel pipe. MATERIAL SPECIFICATIONS HOUSING DESIGN: This six-segment coupling housing is cast in ductile iron per ASTM A 536 Grade 65-45-12. Each housing segment is machined to assure a close dimensional fit with pipe ends that are prepared in accordance with Gruvlok “Large Diameter Roll and Cut Groove Specifications.” GASKET DESIGN: The gasket design is a “C” Style cross section and features a larger cross section to provide optimal sealing throughout the range of pipe dimensional variations and operating conditions. The gasket is available in EPDM and Nitrile, to facilitate use in a wide range of applications. For Gruvlok gasket material recommendations see the Gruvlok catalog. BOLTS & HEAVY HEX NUTS: Heat treated, oval neck track bolts of carbon steel conforming to ASTM A 183 Grade 2, with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563. Bolts and nuts are zinc plated per ASTM B 633 as standard. PIPE END PREPARATION: Pipe grooving is simple, easy and quick. It is critical that the pipe ends be prepared in accordance with the Gruvlok “Large Diameter Roll and Cut Groove Specifications.” For roll grooved pipe, grinding the weld seam on the interior and exterior of the pipe may be required. Not performing this operation may result in improper assembly of the coupling, gasket leakage and damage to the roll grooving machine. GL-7.12 COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com 27 IntroductionCouplingsOutletsFittingsValves & AccessoriesHighPressureDi-ElectricNipplesPlain-EndFittingsHDPECouplingsSock-It®FittingsStainlessSteel MethodRoll GrooversInstallation& AssemblySpecialCoatingsDesignServicesTechnicalDataMaster Format3 Part Specs.PictorialIndexCTS Copper SystemT B D C OD A TB D CODFlareA NOTE: Working pressure and end load values are for standard wall pipe. Range of pipe end separation values are for cut grooved pipe. Roll and Cut Grooving Specifications can be found in the technical data section. • Pipe O.D. must be within specified dimensions. • Gasket Seat must be free from scores, seams, chips, rust or other scale, which may interfere with proper sealing of the gasket. Gasket Seat width, dimension A, is to be measured from the pipe end to the vertical flank in the groove. • Groove width, dimension B, is to be measured between the vertical flank of the groove side walls. • Groove depth must be uniform depth around the entire pipe circumference. (Reference column 6.) • Maximum Flare Diameter is to be measured at the most extreme pipe end. • Out of Roundness: Difference between the maximum and minimum pipe O.D. measured at 90° must not exceed the total pipe O.D. tolerance listed ( Reference column 2). • The maximum allowable tolerance from square cut ends is .125” measured from a true square line. • Beveled end pipe in conformance with ANSI B16.25 (371⁄2° ) is acceptable, however square cut is preferred. SPECIAL ROLL GROOVING INSTRUCTION: • Weld seams must be ground flush with the pipe O.D. and I.D. prior to roll grooving. Failure to do so may result in damage to the roll grooving machine and unacceptable roll grooves may be produced. FIG. 7011 Standard Coupling Roll Groove Cut Groove FIGURE 7011 STANDARD COUPLING Nominal Size O.D. Max. Working Pressure Max. End Load Range of Pipe End Separation Deflection from CL Coupling Dimensions Coupling Bolts*Specified Torque §Approx. Wt. Ea.Per Coupling of Pipe X Y Z Qty. Size Min. Max. In./DN(mm) In./mm PSI/bar Lbs./kN In./mm Degrees(˚)-Minutes(')In./ft-mm/m In./mm In./mm In./mm In./mm Ft.-Lbs./N-m Lbs./Kg 30 O.D. 30.000 300 212,058 0- 9⁄64 0° 16' 0.06 34 39 1⁄2 5 6 1 1⁄4 x 43⁄8 600 800 200 750 762.0 20.7 943.2 0-3.57 4.7 864 1003 127 – - - 90.9 LARGE DIAMETER PIPE ROLL & CUT GROOVE SPECIFICATIONS Nominal IPS Pipe Size O.D.Gasket Seat “A” +.030/-.060 +.77/-1.54 Groove Width “B” ±.030 ±.77 Groove Diameter “C”Groove Depth “D” (Ref. Only) Min. Wall Thickness “T”Max. Flare Dia.Actual Tolerance Actual Tol +0.000 Roll Groove Cut Groove In./DN(mm) In./mm +In./mm -In./mm In./mm In./mm In./mm -In./mm In./mm In./mm In./mm In./mm 30 O.D. 30.000 0.093 0.031 1.750 0.625 29.500 0.063 0.250 0.250 0.625 30.200 750 762.0 2.36 0.79 44.45 15.88 749.30 1.60 6.35 6.35 15.88 767.1 ZY X GL-7.12 For additional details see “Coupling Data Chart Notes” on page 17. * Available in ANSI or metric bolt sizes only as indicated. § – For additional Bolt Torque information,see page 204. See Installation & Assembly directions on page 168. COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com28 The Gruvlok® Figure 7022 coupling with Gruv-Ring forms a flexible grooved end pipe joint for use on steel pipe. Services for this versatile connection include large O.D. mining applications such as process, tailings and slurries. The coupling’s multi-segment design supplies optimum strength for working pressures to 175 PSl. FIG. 7022 Weld Ring Gruv-Ring Coupling MATERIAL SPECIFICATIONS ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval neck track head bolts conforming to SAE J429 Grade 5 with a minimum tensile strength of 105,000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B, or J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. STAINLESS STEEL BOLTS & NUTS: 304SS Stainless Steel bolts and nuts are available as a standard option. (316SS are available for special order). HOUSING: Ductile Iron conforming to ASTM A 536, Grade 65-45-12 COATINGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. GASKETS: Materials Properties as designated in accordance with ASTM D 2000 Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications, air with oil vapors and vegetable and mineral oils. NOT FOR USE IN HOT WATER OR HOT AIR GASKET TYPE: C Style cross section featuring an enhanced larger cross section to provide optimal sealing throughout the range of pipe dimensional variations and operating conditions. LUBRICATION: Standard Gruvlok XtremeTM Fig. 7022 with Type C Ring Fig. 7022 with Type D Ring Fig. 7022 with Type E Ring GL-3.14 COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com 29 IntroductionCouplingsOutletsFittingsValves & AccessoriesHighPressureDi-ElectricNipplesPlain-EndFittingsHDPECouplingsSock-It®FittingsStainlessSteel MethodRoll GrooversInstallation& AssemblySpecialCoatingsDesignServicesTechnicalDataMaster Format3 Part Specs.PictorialIndexCTS Copper SystemFIGURE 7022 WELD RING GRUV-RING COUPLING Nominal Size Pipe O.D. Range Applied Gruv-Ring O.D. Max. Working Pressure Max. End Load Range of Pipe End Separation Deflection from CL Coupling Dimensions Number of Segments Coupling Bolts Approx. Wt. per Segment Total Assembly WeightPer Coupling of Pipe X Y Z Qty. Size In. In./mm In./mm PSI/kPa Lbs./N In./mm Degrees(˚)In./ft-mm/m In./mm In./mm In./mm In./mm Lbs./kg Lbs./kg 30 28.00 - 32.00 33.75 175 156,558 0- 1⁄2 0.85 0.18 37.00 43.25 5.375 6 6 1 1⁄2 x 53⁄4 42 250 711.2 - 812.8 857 1207 696,405 0-12.7 15.0 940 1099 137 19.1 113.4 36 34.00 - 38.00 40.19 175 221,978 0- 1⁄2 0.72 0.15 43.47 50.00 5.375 6 6 1 1⁄2 x 53⁄4 48 290 863.6 - 965.2 1021 1207 987,407 0-12.7 12.5 1104 12.70 137 21.8 131.5 42 40.00 - 44.00 46.63 175 298,790 0- 1⁄2 0.62 0.12 49.84 56.50 5.375 8 8 1 3⁄4 x 6 46 345 1,016.0 - 1,117.6 1184 1207 1,329,084 0-12.7 10.0 1266 1435 137 20.8 156.5 48 46.00 - 50.00 53.13 175 387,905 0- 1⁄2 0.53 0.11 57.16 62.50 5.500 8 16 1 3⁄8 x 53⁄4 73 580 1,168.4 - 1,270.0 1350 1207 1,725,488 0-12.7 9.2 1452 1588 140 32.9 263.1 54 52.00 - 56.00 59.69 175 489,660 0- 1⁄2 0.48 0.10 63.60 69.28 5.625 8 16 1 1⁄2 x 53⁄4 81 650 1,320.8 - 1,422.4 1516 1207 2,178,116 0-12.7 8.3 1615 1760 143 36.7 294.8 60 58.00 - 64.00 66.19 175 602,116 0- 1⁄2 0.43 0.09 70.00 75.71 5.750 10 20 1 1⁄2 x 53⁄4 76 750 1,473.2 - 1,625.6 1681 1207 2,678,346 0-12.7 7.5 1778 1923 146 34.3 340.2 For additional details see “Coupling Data Chart Notes” on page 17. For additional Bolt Torque information, contact an Anvil Representative. NOTE: Impact gun can be used for installation, verify that the output of the impact gun is within the required torque range. FIG. 7022 Weld Ring Gruv-Ring Coupling Y X Z GL-3.14 COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com30 GRUV-RING TYPE C Size Gasket Seat Ring O.D. A E In./mm In./mm In./mm 30 1.75 33.75 750 44.5 857.3 36 1.75 40.19 900 44.5 1020.8 42 1.75 46.63 1050 44.5 1184.3 48 1.75 53.13 1200 44.5 1349.4 54 1.75 59.69 1375 44.5 1516.1 60 1.75 66.19 1500 44.5 1681.2 Gruv-Rings are not to be considered as pipe reinforcement. Additional provision must be provided by the piping system designer if reinforcement is required. GRUV-RING WELDED SHOULDER RINGS For use with Fig. 7022 Couplings GRUV-RING TYPE D Size Gasket Seat Groove Width Groove Diameter Ring O.D. Ring Width A B C E L In./mm In./mm In./mm In./mm In./mm In./mm 30 1.75 0.88 33.00 33.75 3.50 750 44.5 22.2 838.2 857.3 88.9 36 1.75 0.94 39.44 40.19 3.50 900 44.5 23.8 1001.7 1020.8 88.9 42 1.75 1.00 45.81 46.63 3.62 1050 44.5 25.4 1163.6 1184.3 91.9 48 1.75 1.06 52.19 53.13 3.88 1200 44.5 27.0 1349.4 1349.4 98.4 54 1.75 1.13 58.63 59.69 3.88 1375 44.5 28.6 1489.1 1516.1 98.4 60 1.75 1.13 65.06 66.19 3.88 1500 44.5 28.6 1652.6 1681.2 98.4 GRUV-RING TYPE E Size Gasket Seat Groove Diameter Ring O.D.Ring Width A C E L In./mm In./mm In./mm In./mm In./mm 30 1.75 33.00 33.75 3.50 750 44.5 838.2 857.3 88.9 36 1.75 39.44 40.19 3.50 900 44.5 1001.7 1020.8 88.9 42 1.75 45.81 46.63 3.62 1050 44.5 1163.6 1184.3 91.9 48 1.75 52.19 53.13 3.88 1200 44.5 1349.4 1349.4 98.4 54 1.75 58.63 59.69 3.88 1375 44.5 1489.1 1516.1 98.4 60 1.75 65.06 66.19 3.88 1500 44.5 1652.6 1681.2 98.4 A Sealing surface, must be free of scores, seams, and projections. E D WELD WELD Sealing surface, must be free of scores, seams, and projections. WELD WELD E D C A L Sealing surface, must be free of scores, seams, and projections. E D WELD WELD A L C TYPE C TYPE D TYPE E MATERIAL: ASTM A105 Additional material options available upon request. GL-3.14 D - Ring I.D. based on Pipe O.D. Dimensions.D - Ring I.D. based on Pipe O.D. Dimensions. D - Ring I.D. based on Pipe O.D. Dimensions. COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com 31 IntroductionCouplingsOutletsFittingsValves & AccessoriesHighPressureDi-ElectricNipplesPlain-EndFittingsHDPECouplingsSock-It®FittingsStainlessSteel MethodRoll GrooversInstallation& AssemblySpecialCoatingsDesignServicesTechnicalDataMaster Format3 Part Specs.PictorialIndexCTS Copper SystemGRUV-RING WELDED SHOULDER RINGS For use with Fig. 7022 Couplings When ordering, please provide the required information below to your Anvil Representative. JOINT TYPE q Pipe to Pipe (Two Rings Required) q Pipe to Shoulder (One Ring Required) APPLICATION Fluid Media: Working Pressure: Test Pressure: Temperature: Minimum: Maximum: PIPE SPECIFICATION Pipe Material: Nominal Pipe Size: Measured Pipe OD: Pipe Schedule: Wall Thickness: COUPLING CONFIGURATION Size: Number of Joints: Gasket Materials: q Grade "E" EPDM (Green color code) q Grade "T" Nitrile (Orange color code) Coupling Finish: q Rust inhibiting paint – Color: Orange (standard) q Hot Dipped Zinc Galvanized (optional) q Other Colors Available (IE: RAL3000 and RAL9000) LINED PIPE (optional) q Abrasive q Corrosive Lined Thickness: Lined Material: GRUV-RING TYPE q Type C q Type D q Type E GL-3.14 COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com32 FIG. 7000 Lightweight Flexible Coupling The Fig. 7000 Lightweight Flexible Coupling is designed for applications where system flexibility is desired. The Fig. 7000 Coupling is approximately 30% lighter in weight than the Fig. 7001 Coupling, and allows for working pressure ratings up to 600 psi (41.4 bar). The Figure 7000 Lightweight Flexible Coupling is intended for use in several applications. See Gasket Grade Index for gasket recommendations. See technical data section for design factors. MATERIAL SPECIFICATIONS ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B, or J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts and bolts are zinc electroplated followed by a yellow chromate dip. STAINLESS STEEL BOLTS & NUTS: 304SS Stainless Steel bolts and nuts are available as a standard option. (316SS are available for special order). HOUSING: Ductile Iron conforming to ASTM A 536, Grade 65-45-12 COATINGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. GASKETS: Materials Properties as designated in accordance with ASTM D 2000 Grade “EP” EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended. NSF-61 Certified for cold and hot water applications up through 12". Grade “T” Nitrile (Orange color code) 20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. air with oil vapors and vegetable and mineral oils. NOT FOR USE IN HOT WATER OR HOT AIR Grade “O” Fluoro-Elastomer (Blue color code) Size Range: 1" - 8" (C style only) -20°F to 300°F (Service Temperature Range)(-29°C to 149°C) Recommended for high temperature resistance to oxidizing acids, petroleum oils, hydraulic fluids, halogenated hydrocarbons and lubricants. Grade “L” Silicone (Red color code) Size Range: 1" - 8" (C style only) -40°F to 350°F (Service Temperature Range)(-40°C to 177°C) Recommended for dry, hot air and some high temperature chemical services. GASKET TYPE: Standard C Style (1" - 8") Flush Gap (1" - 8") LUBRICATION: Standard Gruvlok Gruvlok XtremeTM (Do Not use with Grade “L”) GL-3.14 For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com 33 IntroductionCouplingsOutletsFittingsValves & AccessoriesHighPressureDi-ElectricNipplesPlain-EndFittingsHDPECouplingsSock-It®FittingsStainlessSteel MethodRoll GrooversInstallation& AssemblySpecialCoatingsDesignServicesTechnicalDataMaster Format3 Part Specs.PictorialIndexCTS Copper SystemFIG. 7000 Lightweight Flexible Coupling FIGURE 7000 COUPLING Nominal Size O.D.Max. Working Pressure Max. End Load Range of Pipe End Separation Deflection from CL Coupling Dimensions Coupling Bolts Specified Torque §Approx. Wt. Ea. Per Coupling of Pipe X Y Z Qty. Size Min. Max. In./DN(mm) In./mm PSI/bar Lbs./kN In./mm Degrees(˚)-Minutes(')In./ft-mm/m In./mm In./mm In./mm In./mm Ft.-Lbs./N-m Lbs./Kg 1 1.315 600 815 0- 1⁄32 1° 22' 0.29 2 3⁄8 41⁄4 13⁄4 2 3⁄8 x 21⁄4 30 45 1.3 25 33.4 41.4 3.62 0-0.79 23.8 60 108 44 M10 x 57 40 60 0.6 11⁄4 1.660 600 1,299 0- 1⁄32 1° 5' 0.23 2 3⁄4 43⁄8 13⁄4 2 3⁄8 x 21⁄4 30 45 1.4 32 42.2 41.4 5.78 0-0.79 18.8 70 111 44 M10 x 57 40 60 0.6 11⁄2 1.900 600 1,701 0- 1⁄32 0° 57' 0.20 3 4 5⁄8 13⁄4 2 3⁄8 x 21⁄4 30 45 1.5 40 48.3 41.4 7.57 0-0.79 16.5 76 117 44 M10 x 57 40 60 0.7 2 2.375 600 2,658 0- 1⁄32 0° 45' 0.16 3 1⁄2 51⁄2 13⁄4 2 3⁄8 x 21⁄4 30 45 1.7 50 60.3 41.4 11.82 0-0.79 13.1 89 140 44 M10 x 57 40 60 0.8 21⁄2 2.875 600 3,895 0- 1⁄32 0° 37' 0.13 4 5 3⁄4 13⁄4 2 3⁄8 x 21⁄4 30 45 1.9 65 73.0 41.4 17.33 0-0.79 10.9 102 146 44 M10 x 57 40 60 0.9 3 O.D. 2.996 600 4,230 0- 1⁄32 0° 36' 0.13 4 6 1⁄8 13⁄4 2 3⁄8 x 21⁄4 30 45 2.3 76.1 76.1 41.4 18.82 0-0.79 10.4 102 156 44 M10 x 57 40 60 1.0 3 3.500 600 5,773 0- 1⁄32 0° 31' 0.11 4 5⁄8 63⁄4 13⁄4 2 1⁄2 x 23⁄4 80 100 2.9 80 88.9 41.4 25.68 0-0.79 8.9 117 171 44 M12 x 70 110 150 1.3 31⁄2 4.000 600 7,540 0- 1⁄32 0° 27' 0.09 5 1⁄8 75⁄8 13⁄4 2 1⁄2 x 3 80 100 3.1 90 101.6 41.4 33.54 0-0.79 7.8 130 194 44 M12 x 76 110 150 1.4 41⁄4 O.D. 4.250 600 8,512 0- 3⁄32 1° 16' 0.26 5 1⁄2 73⁄4 2 2 1⁄2 x 3 80 100 4.0 108.0 108.0 41.4 37.86 0-2.38 22.0 140 197 51 M12 x 76 110 150 1.8 4 4.500 600 9,543 0- 3⁄32 1° 12' 0.25 5 7⁄8 81⁄8 2 2 1⁄2 x 3 80 100 4.6 100 114.3 41.4 42.45 0-2.38 20.8 149 206 51 M12 x 76 110 150 2.1 51⁄4 O.D. 5.236 500 10,766 0- 3⁄32 1° 2' 0.21 6 1⁄2 91⁄8 2 2 5⁄8 x 31⁄2 100 130 5.7 133.0 133.0 34.5 47.89 0-2.38 17.9 165 232 51 M16 x 85 135 175 2.6 51⁄2 O.D. 5.500 500 11,879 0- 3⁄32 0° 59' 0.20 6 3⁄4 93⁄8 2 2 5⁄8 x 31⁄2 100 130 6 139.7 139.7 34.5 52.84 0-2.38 17.0 171 238 51 M16 x 85 135 175 2.7 5 5.563 500 12,153 0- 3⁄32 0° 58' 0.20 7 9 5⁄8 2 2 5⁄8 x 31⁄2 100 130 6.1 125 141.3 34.5 54.06 0-2.38 16.8 178 244 51 M16 x 85 135 175 2.8 61⁄4 O.D. 6.259 500 15,384 0- 3⁄32 0° 51' 0.18 7 1⁄2 103⁄8 2 2 5⁄8 x 31⁄2 100 130 6.7 159.0 159.0 34.5 68.43 0-2.38 14.9 191 264 51 M16 x 85 135 175 3.0 61⁄2 O.D. 6.500 500 16,592 0- 3⁄32 0° 50' 0.17 7 3⁄4 103⁄4 2 2 5⁄8 x 31⁄2 100 130 7.0 165.1 165.1 34.5 73.80 0-2.38 13.1 197 273 51 M16 x 85 135 175 3.2 6 6.625 500 17,236 0- 3⁄32 0° 49' 0.17 8 11 2 2 5⁄8 x 31⁄2 100 130 8.1 150 168.3 34.5 76.67 0-2.38 14.1 203 279 51 M16 x 85 135 175 3.7 8 8.625 500 29,213 0- 3⁄32 0° 37' 0.13 10 1⁄2 1213⁄16 21⁄2 2 3⁄4 x 41⁄2 130 180 14.2 200 219.1 34.5 129.95 0-2.38 10.9 264 337 60 M20 x 110 175 245 6.4 Y Z X GL-6.11 For additional details see “Coupling Data Chart Notes” on page 17. § – For additional Bolt Torque information, see page 204. See Installation & Assembly directions on page 169. Not for use in copper systems. NOTES: Range of Pipe End Separation and Angular Deflection values are for roll grooved pipe and may be doubled for cut groove pipe. See page 204 for details. Refer to page 210 for Misalignment & Deflection Calculations and page 211 for Curve Layout Calculations. COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com34 FIG. 7400 Rigidlite® Coupling The Fig. 7400 Rigidlite Coupling from Gruvlok is specially designed to provide a rigid, locked-in pipe connection to meet the specific demands of rigid design steel pipe systems. Fast and easy swing-over installation of the rugged lightweight housing produces a secure, rigid pipe joint. The Fig. 7400 Rigidlite Coupling is UL/ULC Listed and FM Approved for 300 psi (20.7 bar) with roll grooved or cut grooved steel pipe prepared in accordance with Gruvlok grooving specifications. The galvanized Fig. 7400 is ideal for stainless steel piping application where the external corrosion properties of stainless steel is not required. For Gruvlok coupling pressure ratings on stainless steel pipe, please refer to page 214. MATERIAL SPECIFICATIONS ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B, or J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts and bolts are zinc electroplated followed by a yellow chromate dip. STAINLESS STEEL BOLTS & NUTS: 304SS Stainless Steel bolts and nuts are available as a standard option. (316SS are available for special order). HOUSING: Ductile Iron conforming to ASTM A 536, Grade 65-45-12. COATINGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. GASKETS: Materials Properties as designated in accordance with ASTM D 2000 Grade “EP” EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended. NSF-61 Certified for cold and hot water applications up through 12". Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. air with oil vapors and vegetable and mineral oils. NOT FOR USE IN HOT WATER OR HOT AIR Grade “O” Fluoro-Elastomer (Blue color code) Size Range: 1" - 8" (C style only) 20°F to 300°F (Service Temperature Range)(-29°C to 149°C) Recommended for high temperature resistance to oxidizing acids, petroleum oils, hydraulic fluids, halogenated hydrocarbons and lubricants. Grade “L” Silicone (Red color code) Size Range: 1" - 8" (C style only) -40°F to 350°F (Service Temperature Range)(-40°C to 177°C) Recommended for dry, hot air and some high temperature chemical services. GASKET TYPE: Standard C Style (1" - 8") Flush Gap (1" - 8") LUBRICATION: Standard Gruvlok Gruvlok XtremeTM (Do Not use with Grade “L”) DN 50 and DN 200 sizes are VdS approved. GL-3.14 For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com 35 IntroductionCouplingsOutletsFittingsValves & AccessoriesHighPressureDi-ElectricNipplesPlain-EndFittingsHDPECouplingsSock-It®FittingsStainlessSteel MethodRoll GrooversInstallation& AssemblySpecialCoatingsDesignServicesTechnicalDataMaster Format3 Part Specs.PictorialIndexCTS Copper SystemFIG. 7400 Rigidlite® Coupling FIGURE 7400 RIGIDLITE COUPLING Nominal Size O.D.Max. Wk. Pressure Max. End Load Range of Pipe End Separation Coupling Dimensions Coupling Bolts Specified Torque §Approx. Wt. Ea.X Y Z Qty. Size Min. Max. In./DN(mm) In./mm PSI/bar Lbs./kN In./mm In./mm In./mm In./mm In./mm Ft.-Lbs./N-m Lbs./Kg 1 1.315 300 407 0- 1⁄32 21⁄4 41⁄2 13⁄4 2 3⁄8 x 21⁄4 30 45 1.2 25 33.4 20.7 1.81 0-0.79 57 114 44 M10 x 57 40 60 0.5 11⁄4 1.660 300 649 0- 1⁄32 25⁄8 43⁄4 13⁄4 2 3⁄8 x 21⁄4 30 45 1.3 32 42.2 20.7 2.89 0-0.79 67 121 44 M10 x 57 40 60 0.6 11⁄2 1.900 300 851 0- 1⁄32 27⁄8 47⁄8 13⁄4 2 3⁄8 x 21⁄4 30 45 1.4 40 48.3 20.7 3.78 0-0.79 73 124 44 M10 x 57 40 60 0.6 2 2.375 300 1,329 0- 1⁄32 31⁄4 51⁄2 13⁄4 2 3⁄8 x 21⁄4 30 45 1.6 50* 60.3 20.7 5.91 0-0.79 83 140 44 M10 x 57 40 60 0.7 21⁄2 2.875 300 1,948 0- 1⁄32 37⁄8 6 1 3⁄4 2 3⁄8 x 21⁄4 30 45 1.9 65 73.0 20.7 8.66 0-0.79 98 152 44 M10 x 57 40 60 0.9 3 O.D. 2.996 300 2,115 0- 1⁄32 4 5 7⁄8 13⁄4 2 3⁄8 x 21⁄4 30 45 1.9 76.1 76.1 20.7 9.41 0-0.79 102 149 44 M10 x 57 40 60 0.9 3 3.500 300 2,886 0- 1⁄32 41⁄2 63⁄4 13⁄4 2 3⁄8 x 23⁄4 30 45 2.1 80 88.9 20.7 12.84 0-0.79 114 171 44 M10 x 70 40 60 1.0 4 4.500 300 4,771 0- 3⁄32 55⁄8 73⁄4 17⁄8 2 3⁄8 x 23⁄4 30 45 3.1 100 114.3 20.7 21.22 0-2.38 143 197 48 M10 x 70 40 60 1.4 51⁄2 O.D. 5.500 300 7,127 0- 3⁄32 63⁄4 91⁄4 2 2 1⁄2 x 3 80 100 4.5 139.7 139.7 20.7 31.70 0-2.38 171 235 51 M12 x 76 110 150 2.0 5 5.563 300 7,292 0- 3⁄32 67⁄8 91⁄4 2 2 1⁄2 x 3 80 100 4.6 125 141.3 20.7 32.44 0-2.38 175 235 51 M12 x 76 110 150 2.1 61⁄2 O.D. 6.500 300 9,955 0- 3⁄32 73⁄4 103⁄8 2 2 1⁄2 x 3 80 100 5.5 165.1 165.1 20.7 44.28 0-2.38 200 264 51 M12 x 76 110 150 2.5 6 6.625 300 10,341 0- 3⁄32 77⁄8 103⁄8 2 2 1⁄2 x 3 80 100 5.5 150 168.3 20.7 46.00 0-2.38 200 264 51 M12 x 76 110 150 2.5 8 8.625 300 17,528 0- 3⁄32 101⁄4 123⁄4 23⁄8 2 1⁄2 x 3 80 100 8.4 200* 219.1 20.7 77.97 0-2.38 260 324 60 M12 x 76 110 150 3.8 Y Z X GL-6.11 For additional details see “Coupling Data Chart Notes” on page 17. * DN 50 and DN 200 sizes are VdS approved. § – For additional Bolt Torque information, see page 204. See Installation & Assembly directions on page 170. NOTE: Range of Pipe End Seperation values are for roll grooved pipe and may be doubled for cut groove pipe. Other sizes available, contact an Anvil Representative for more information. COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com36 FIG. 7003 Hingelok® Coupling The Fig. 7003 Hingelok Coupling is specially designed for applications requiring a quick connection and/or disconnection of a pipe joint. The Fig. 7003 Hingelok Coupling is ideal for those applications where frequent pipe removal is required for maintenance or any other reason. Fig. 7003 Hingelok Coupling provides for system working pressure ratings up to 300 psi (20.7 bar). The Fig. 7003 Hingelok Coupling halves are permanently hinged to provide an assembly that eases handling and installation. The two coupling halves are hinged for ease of handling and are secured by a cam-action handle. Sizes 1" to 4" use toggle link plates and sizes 5" to 8" use a toggle bolt to attach the cam-action handle to the housings. The cam-action locking handle permits rapid installation without the need for additional tools and maintains secure closure of the coupling into the pipe grooves. Final assembly of the locking pin to the Hingelok Coupling adds an extra measure of security required in critical pipe joint applications. MATERIAL SPECIFICATIONS HOUSING: Ductile Iron conforming to ASTM A 536, Grade 65-45-12. COATINGS: Rust inhibiting paint Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. HANDLE: Sizes 1" - 4": Cold Rolled Carbon Steel Handles Sizes 5” - 8": Cast Ductile Iron Handles LINKS: Sizes 1" - 4": Cold Rolled Carbon Steel Links Sizes 5" - 8": Heat Treated Steel Links LOCKING PIN: Locking Pin: Spring Steel GASKETS: Materials Properties as designated in accordance with ASTM D 2000 Grade “EP” EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended. NSF-61 Certified for cold and hot water applications up through 12". Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. air with oil vapors and vegetable and mineral oils. NOT FOR USE IN HOT WATER OR HOT AIR. Grade “O” Fluoro-Elastomer (Blue color code) Size Range: 1" - 8" (C style only) 20°F to 300°F (Service Temperature Range)(-29°C to 149°C) Recommended for high temperature resistance to oxidizing acids, petroleum oils, hydraulic fluids, halogenated hydrocarbons and lubricants. Grade “L” Silicone (Red color code) Size Range: 1" - 8" (C style only) -40°F to 350°F (Service Temperature Range)(-40°C to 177°C) Recommended for dry, hot air and some high temperature chemical services. DO NOT USE GRUVLOK XTREME LUBRICANT WITH GRADE “L” SILICONE GASKET. GASKET TYPE: Standard C Style (1" - 8") Flush Gap (1" - 8") LUBRICATION: Standard Gruvlok Gruvlok XtremeTM (Do Not use with Grade “L”) SIZES 1" - 4" SIZES 5" - 8" GL-3.14 COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com 37 IntroductionCouplingsOutletsFittingsValves & AccessoriesHighPressureDi-ElectricNipplesPlain-EndFittingsHDPECouplingsSock-It®FittingsStainlessSteel MethodRoll GrooversInstallation& AssemblySpecialCoatingsDesignServicesTechnicalDataMaster Format3 Part Specs.PictorialIndexCTS Copper SystemFIG. 7003 Hingelok® Coupling FIGURE 7003 HINGELOK COUPLING Nominal Size O.D.Max. Wk. Pressure Max. End Load Range of Pipe End Separation Deflection from CL Coupling Dimensions Approx. Wt. Ea.Per Coupling of Pipe X Y Z In./DN(mm) In./mm PSI/bar Lbs./kN In./mm Degrees(˚)-Minutes(')In./ft-mm/m In./mm In./mm In./mm Lbs./Kg 1* 1.315 300 407 0- 1⁄32 1° 22' 0.29 3 4 1 3⁄4 1.4 25 33.4 20.7 1.81 0-0.79 23.8 76 101 44 0.6 11⁄4* 1.660 300 649 0- 1⁄32 1° 5' 0.23 3 7⁄16 47⁄16 17⁄8 1.5 32 42.2 20.7 2.89 0-0.79 18.8 87 113 48 0.7 11⁄2 1.900 300 851 0- 1⁄32 0° 57' 0.20 3 5⁄8 41⁄4 17⁄8 1.7 40 48.3 20.7 3.78 0-0.79 16.5 92 108 48 0.8 2 2.375 300 1,329 0- 1⁄32 0° 45' 0.16 4 1⁄4 47⁄8 17⁄8 2.2 50 60.3 20.7 5.91 0-0.79 13.1 108 124 48 1.0 21⁄2 2.875 300 1,948 0- 1⁄32 0° 37' 0.13 5 1⁄4 57⁄8 17⁄8 3.2 65 73.0 20.7 8.66 0-0.79 10.9 133 149 48 1.5 3 3.500 300 2,886 0- 1⁄32 0° 31' 0.11 5 5⁄8 61⁄2 17⁄8 3.6 80 88.9 20.7 12.84 0-0.79 8.9 143 165 48 1.6 4 4.500 300 4,771 0- 3⁄32 1° 12' 0.25 7 7 3⁄4 2 5.1 100 114.3 20.7 21.22 0-2.38 20.8 178 197 51 2.3 5 5.563 300 7,292 0- 3⁄32 0° 58' 0.20 8 5⁄8 91⁄2 21⁄8 9.5 125 141.3 20.7 32.44 0-2.38 16.8 219 241 54 4.3 6 6.625 300 10,341 0- 3⁄32 0° 49' 0.17 9 7⁄8 107⁄8 21⁄8 11.2 150 168.3 20.7 46.00 0-2.38 14.14 251 276 54 5.1 8 8.625 300 17,528 0- 3⁄32 0° 37' 0.13 12 13 1⁄8 21⁄2 18.1 200 219.1 20.7 77.97 0-2.38 10.9 305 333 64 8.2 Y X Z GL-3.14 For additional details see “Coupling Data Chart Notes” on page 17. See Installation & Assembly directions on page 174. Not for use in copper systems. NOTES: * 1" and 11/4" are import products. Range of Pipe End Separation and Angular Deflection values are for roll grooved pipe and may be doubled for cut groove pipe. See page 204 for details. Refer to page 210 for Misalignment & Deflection Calculations and page 211 for Curve Layout Calculations. SPECIAL NOTE: Fig. 7003 Hingelok Couplings are not designed for eccentric loading and therefore are not recommended for use at the end of concrete pumping booms or vertical risers above 30 feet (9.1 meters). Shockload must be considered and is to be included in the maximum working pressure listed above. Coupling keys, gasket cavity, and pipe grooves must be kept free of all foreign matter. Proper anchoring practice must always be exercised. CAUTION: Hammering or banging on the handle or coupling housing could cause serious damage to the locking device and coupling assembly. The result may be an unsuitable pipe joint and unusable coupling assembly. When re-using, always check for gasket damage, housing hinge and handle for looseness, distortion, bending or any other damage. COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com38 FIG. 7010 Reducing Coupling The Fig. 7010 Reducing Coupling makes it possible to directly connect two different pipe sizes, eliminating the need for two couplings and a reducing fitting. The specially designed reducing coupling gasket with a center rib assures proper positioning of the gasket and prevents the smaller pipe from telescoping into the larger during assembly. Fig. 7010 Reducing Coupling allows for working pressure ratings up to 500 PSI (34.5 bar). Not recommended for vacuum applications. MATERIAL SPECIFICATIONS ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B, or J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts are zinc electroplated followed by a yellow chromate dip. HOUSING: Ductile Iron conforming to ASTM A 536, Grade 65-45-12, or Malleable Iron conforming to ASTM A 47, Grade 32510. COATINGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. GASKETS: Materials Properties as designated in accordance with ASTM D 2000 Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. air with oil vapors and vegetable and mineral oils. NOT FOR USE IN HOT WATER OR HOT AIR. LUBRICATION: Standard Gruvlok Gruvlok XtremeTM (Do Not use with Grade “L”) GL-3.14 For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. COUPLINGS FOR GROOVED-END PIPE www.anvilintl.com 39 IntroductionCouplingsOutletsFittingsValves & AccessoriesHighPressureDi-ElectricNipplesPlain-EndFittingsHDPECouplingsSock-It®FittingsStainlessSteel MethodRoll GrooversInstallation& AssemblySpecialCoatingsDesignServicesTechnicalDataMaster Format3 Part Specs.PictorialIndexCTS Copper SystemFIG. 7010 Reducing Coupling FIGURE 7010 REDUCING COUPLING Nominal Size Larger O.D. Smaller O.D. Max. Working Pressure Max. End Load Range of Pipe End Separation Deflection from CL Coupling Dimensions Coupling Bolts Specified Torque §Approx. Wt. Ea.Per Coupling of Pipe X Y Z Qty. Size Min. Max. In./DN(mm) In./mm In./mm PSI/bar Lbs./kN In./mm Degrees(˚)-Minutes(')In./ft-mm/m In./mm In./mm In./mm In./mm Ft.-Lbs./N-m Lbs./Kg 2 x 11⁄2 2.375 1.900 500 2,215 0- 1⁄32 0° 45' 0.16 3 5⁄8 57⁄8 17⁄8 2 1⁄2 x 23⁄4 80 100 2.0 50 x 40 60.3 48.3 34.5 9.85 0-0.79 13.1 92 149 48 M12 x 76 110 150 0.9 21⁄2 x 2 2.875 2.375 500 3,246 0- 1⁄32 0° 37' 0.13 4 1⁄4 63⁄8 17⁄8 2 1⁄2 x 23⁄4 80 100 3.5 65 x 50 73.0 60.3 34.5 14.44 0-0.79 10.9 108 162 48 M12 x 76 110 150 1.6 3 x 2 3.500 2.375 500 4,811 0- 1⁄32 0° 31' 0.11 4 7⁄8 71⁄8 17⁄8 2 1⁄2 x 23⁄4 80 100 4.4 80 x 50 88.9 60.3 34.5 21.40 0-0.79 8.9 124 181 48 M12 x 76 110 150 2.0 3 x 21⁄2 3.500 2.875 500 4,811 0- 1⁄32 0° 31' 0.11 4 7⁄8 71⁄8 17⁄8 2 1⁄2 x 23⁄4 80 100 4.1 80 x 65 88.9 73.0 34.5 21.40 0-0.79 8.9 124 181 48 M12 x 76 110 150 1.9 4 x 2 4.500 2.375 500 7,952 0- 3⁄32 1° 12' 0.25 6 1⁄4 87⁄8 2 2 5⁄8 x 31⁄2 100 130 8.9 100 x 50 114.3 60.3 34.5 35.37 0-2.38 20.8 159 225 51 M16 x 95 135 175 4.0 4 x 21⁄2 4.500 2.875 500 7,952 0- 3⁄32 1° 12' 0.25 6 1⁄4 87⁄8 2 2 5⁄8 x 31⁄2 100 130 7.9 100 x 65 114.3 73.0 34.5 35.37 0-2.38 20.8 159 225 51 M16 x 95 135 175 3.6 4 x 3 4.500 3.500 500 7,952 0- 3⁄32 1° 12' 0.25 6 1⁄4 87⁄8 2 2 5⁄8 x 31⁄2 100 130 6.7 100 x 80 114.3 88.9 34.5 35.37 0-2.38 20.8 159 225 51 M16 x 95 135 175 3.0 5 x 4 5.563 4.500 500 12,153 0- 3⁄32 1° 58' 0.20 7 1⁄4 105⁄8 21⁄8 2 3⁄4 x 41⁄2 130 180 11.4 125 x 100 141.3 114.3 34.5 54.06 0-2.38 16.8 184 270 54 M20 x 115 175 245 5.2 6 x 4 6.625 4.500 500 17,236 0- 3⁄32 0° 49' 0.17 8 1⁄4 115⁄8 21⁄8 2 3⁄4 x 41⁄2 130 180 13.4 150 x 100 168.3 114.3 34.5 76.67 0-2.38 14.1 210 295 54 M20 x 115 175 245 6.1 6 x 5 6.625 5.562 500 17,236 0- 3⁄32 0° 49' 0.17 8 1⁄2 115⁄8 21⁄8 2 3⁄4 x 41⁄2 130 180 13.5 150 x 125 168.3 141.3 34.5 76.67 0-2.38 14.1 216 295 54 M20 x 115 175 245 6.1 8 x 6 8.625 6.625 500 29,213 0- 3⁄32 0° 37' 0.13 10 1⁄2 14 2 1⁄4 2 3⁄4 x 41⁄2 130 180 17.7 200 x 150 219.1 168.3 34.5 129.95 0-2.38 10.9 267 356 57 M20 x 115 175 245 8.0 Fig. 7010 Coupling with Gasket GL-10.12 NOTES: Fig. 7010 Reducing Coupling should not be used with end caps in systems where a vacuum may be developed. Contact your Anvil Representative for details. Range of Pipe End Separation and Angular Deflection values are for roll grooved pipe and may be doubled for cut groove pipe. See page 204 for details. Refer to page 210 for Misalignment & Deflection Calculations and page 211 for Curve Layout Calculations. For additional details see “Coupling Data Chart Notes” on page 17. § – For additional Bolt Torque information, see page 204. See Installation & Assembly directions on page 175. Not for use in copper systems. victaulic.com 06.02 1482 Rev P Updated 05/2020 © 2020 Victaulic Company. All rights reserved. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. 1.0 PRODUCT DESCRIPTION Available Sizes: • 1 – 12”/DN25 – DN300 • For sizes 14 – 24"/DN350 – DN600, please reference publication 20.02: Victaulic Style W07 AGS™ Rigid Coupling Maximum Working Pressure: • Accommodates pressures ranging from full vacuum (29.9 in Hg/760 mm Hg) up to 750 psi/5171 kPa/52 bar • Working pressure dependent on material, wall thickness and size of pipe Application: • Joins Victaulic Original Groove System (OGS) roll grooved pipe and cut grooved pipe, valves, fittings and accessories • Provides a rigid pipe joint designed to restrict axial or angular movement. Contact Victaulic for information on torsional resistance. Pipe Materials: • Carbon steel • For use on stainless steel pipe, please reference publication 17.09: Victaulic Grooved Couplings Performance Data for Stainless Steel Pipe. • For exceptions reference section 6.0 Notifications Pipe Preparation • Cut or roll grooved in accordance with publication 25.01: Victaulic Standard Groove Specifications Code Requirements: • Support and hanging requirements correspond to ASME B31.1 Power Piping Code, ASME B31.9 Building Services Code and NFPA 13 Sprinkler Systems 2.0 CERTIFICATION/LISTINGS NOTES • Download publication 10.01 for Fire Protection Certifications/Listings Reference Guide. • See publication 02.06: Victaulic Potable Water Approvals ANSI/NSF for potable water approvals if applicable. Victaulic® Zero-Flex™ Rigid Coupling Style 07 06.02 1 System No.Location Submitted By Date Spec Section Paragraph Approved Date 06.02 1482 Rev P Updated 05/2020 © 2020 Victaulic Company. All rights reserved. victaulic.com Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) Standard: Orange enamel. Optional: Hot dipped galvanized conforming to ASTM A153. Optional: Contact Victaulic with your requirements for other coatings. Gasket: (specify choice1) Grade “E” EPDM EPDM (Green stripe color code). Temperature range –30ºF to +230ºF/–34ºC to +110ºC. May be specified for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot +180°F/+82°C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR USE WITH PETROLEUM SERVICES OR STEAM SERVICES. Grade “T” Nitrile Nitrile (Orange stripe color code). Temperature range -20ºF to +180ºF/-29ºC to +82ºC. May be specified for oil related services, including air with oil vapor, this gasket may be specified for temperatures rated up to +180°F/+82°C. For water related services, this gasket may be specified for temperatures rated up to +150°F/+66°C. For oil free, dry air services, this gasket may be specified for temperatures rated up to +140°F/+60°C. NOT COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES Others For alternate gasket selection, reference publication 05.01: Victaulic Seal Selection Guide. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 (metric) Class 9.8 (M10-M16) and Class 8.8 (M20 and greater). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial – heavy hex nuts) and ASTM A563M Class 9 (metric – hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 ZN/FE5, finish Type III (imperial) or Type II (metric). 3.0 SPECIFICATIONS – MATERIAL 2 victaulic.com 06.02 1482 Rev P Updated 05/2020 © 2020 Victaulic Company. All rights reserved. victaulic.com 4.0 DIMENSIONS Style 07 Zero-Flex™ Rigid C oupling Size Pipe End Separation2 Bolt /Nut Dimensions Weight Nominal inches DN Actual Outside Diameter inches mm Allowable inches mm Qty Size inches mm X inches mm Y inches mm Z inches mm Approximate (Ea ch) lbs kg 1 DN25 1.315 33.7 0.05 1.2 2 3⁄8 x 2 2.36 60 4.22 107 1.84 47 1.6 0.7 1 1/4 DN32 1.660 42.4 0.05 1.2 2 3⁄8 x 2 2.69 68 4.62 117 1.84 47 1.6 0.7 1 1/2 DN40 1.900 48.3 0.05 1.2 2 3⁄8 x 2 2.94 75 5.81 148 1.84 47 1.6 0.7 2 DN50 2.375 60.3 0.07 1.7 2 1/2 x 2 1/2 3.35 85 5.78 147 1.84 47 2.3 1.0 2 1/2 2.875 73.0 0.07 1.7 2 1/2 x 23/4 3.88 98 6.38 162 1.84 47 2.6 1.2 DN65 3.000 76.1 0.07 1.7 2 M12 x 70.0 4.21 107 6.61 168 1.84 47 3.6 1.6 3 DN80 3.500 88.9 0.07 1.7 2 1/2 x 2 1/2 4.54 115 6.81 173 1.84 47 3.0 1.4 4 DN100 4.500 114.3 0.16 4.1 2 1/2 x 2 3/4 5.81 148 8.21 209 2.07 53 5.3 2.4 4.250 108.0 0.16 4.1 2 M12 x 70.0 5.56 141 7.98 203 2.07 53 5.2 2.4 5.250 133.0 0.16 4.1 2 M16 x 82.5 6.69 170 9.60 244 2.07 53 7.4 3.4 DN125 5.500 139.7 0.16 4.1 2 M16 x 82.5 6.94 176 9.82 249 2.07 53 7.6 3.4 5 5.563 141.3 0.16 4.1 2 5⁄8 x 3 1/4 7.03 179 9.89 251 2.07 53 7.4 3.4 6.250 159.0 0.16 4.1 2 M16 x 82.5 7.84 199 10.54 268 2.07 53 9.2 4.2 6.500 165.1 0.16 4.1 2 M16 x 82.5 8.13 207 10.84 275 2.07 53 8.3 3.8 6 DN150 6.625 168.3 0.16 4.1 2 5⁄8 x 3 1/4 8.26 210 10.83 275 2.07 53 8.3 3.8 200A 8.515 216.3 0.19 4.8 2 M20 x 110 10.47 266 13.62 346 2.50 64 14.9 6.8 8 DN200 8.625 219.1 0.19 4.8 2 3/4 x 4 1/4 10.54 268 13.74 349 2.51 64 15.1 6.8 250A 10.528 267.4 0.13 3.3 2 M22 x 165 12.64 321 16.97 431 2.56 65 11.3 25.0 10 DN250 10.750 273.0 0.13 3.3 2 7⁄8 x 6 1/2 12.86 327 16.98 431 2.56 65 23.5 10.7 300A 12.539 318.5 0.13 3.3 2 M22 x 165 14.65 372 18.90 480 2.56 65 12.8 28.2 12 DN300 12.750 323.9 0.13 3.3 2 7⁄8 x 6 1/2 14.86 377 18.88 480 2.56 65 28.2 12.8 14 – 24 DN350 – DN600 For sizes 14 – 24"/DN350 – DN600, please reference publication 20.02: Victaulic Style W07 AGS™ Rigid Coupling. 2 The allowable pipe end separation dimension shown is for system layout purposes only. Style 07 Zero-Flex™ rigid couplings are considered rigid connections and will not accommodate expansion/contraction or angular movement of the piping system. Contact Victaulic for torsional resistance information. Z X Y 3 victaulic.com 06.02 1482 Rev P Updated 05/2020 © 2020 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE Style 07 Zero-Flex™ Rigid Coupling Size Maximum Working Pressure3 Maximum End Load3NominalActual Outside Diameter inches DN inches mm psi kPa lbs N 1 1.315 750 650 DN25 33.7 5171 2890 1 1/4 DN32 1.660 42.4 750 5171 1620 7210 1 1/2 DN40 1.900 48.3 750 5171 2130 9480 2 2.375 750 3320 DN50 60.3 5171 14775 2 1/2 2.875 73.0 750 5171 4875 21695 3.000 750 5300 DN65 76.1 5171 23585 3 3.500 750 7215 DN80 88.9 5171 32105 4 4.500 750 11925 DN100 114.3 5171 53065 4.250 750 10635 108.0 5171 47325 5.250 700 15145 133.0 4826 67395 5.500 700 16625 DN125 139.7 4826 73980 5 5.563 750 18225 141.3 5171 81100 6.250 700 21465 159.0 4826 95520 6.500 700 23225 165.1 4826 103305 6 6.625 700 24130 DN150 168.3 4826 107380 8.515 600 34200 200A 216.3 4137 152200 8 8.625 600 35000 DN200 219.1 4137 155750 10.528 500 43500 250A 267.4 3447 193600 10 10.750 500 45400 DN250 273.0 3447 202030 318.5 400 49400 300A 12.539 2758 219800 12 12.750 400 51000 DN300 323.9 2758 226950 14–24 For sizes 14 – 24"/DN350 – DN600, please reference publication 20.02: Victaulic Style W07 AGS™ Rigid Coupling. DN350–DN600 3 Working Pressure and End Load are total, from all internal and external loads, based on ANSI B36.10 sized carbon steel pipe, grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. NOTE • WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 ½ times the figures shown. 4 victaulic.com 06.02 1482 Rev P Updated 05/2020 © 2020 Victaulic Company. All rights reserved. victaulic.com 6.0 NOTIFICATIONS WARNING • Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. • Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. WARNING • Style 07 Zero-Flex™ Rigid Couplings shall not be used to join PVC or CPVC pipe. Failure to follow this instruction could cause product failure, resulting in death or serious personal injury and property damage. WARNING • Victaulic RX roll sets shall be used when grooving light-wall/thin-wall stainless steel pipe for use with Victaulic Couplings. Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe could cause product failure, resulting in death or serious personal injury and property damage. NOTICE • Victaulic RX grooving rolls must be ordered separately. They are identified by a silver color and the designation RX on the front of the roll sets. NOTICE • Victaulic does not recommend the use of any furnace butt-welded pipe with sizes NPS 2”/DN50 and smaller Victaulic gasketed joint products. This includes, but is not limited to, ASTM A53 Type F pipe. 5 victaulic.com 06.02 1482 Rev P Updated 05/2020 © 2020 Victaulic Company. All rights reserved. victaulic.com User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products Victaulic products for a particular end-use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications, and the applicable building codes and related Victaulic reserves the right to change product specifications, designs and standard regulations as well as Victaulic performance, maintenance, safety, and warning equipment without notice and without incurring obligations. instructions. Nothing in this or any other document, nor any verbal recommendation, Installationadvice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale, installation instructions of the product you are installing. Handbooks are included with each shipment guide, or this disclaimer.of Victaulic products, providing complete installation and assembly data, and are available Intellectual Property Rights in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warrantyproduct, service, or design is intended, or should be constructed, to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details.under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such Trademarks material, product, service, or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right. The terms “Patented” or “Patent Pending” refer to design or utility patents Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. 7.0 REFERENCE MATERIALS 02.06: Victaulic Potable Water Approvals ANSI/NSF 05.01: Victaulic Seal Selection Guide - Elastomeric Seal Construction 06.17: Couplings and Fittings for JIS Pipe 10.01: Victaulic Products for Fire Protection Pipings Systems - Regulatory Approval Reference Guide 17.01: Victaulic Pipe Preparation for Use on Stainless Steel Pipe with Victaulic Products 17.09: Victaulic Ductile Iron Grooved Couplings Performance Data for Stainless Steel Pipe 20.02: Victaulic AGS Rigid Coupling Style W07 26.01: Victaulic Design Data 29.01: Victaulic Terms and Conditions of Sale I-100: Victaulic Field Installation Handbook I-ENDCAP: Victaulic End Cap Installation Safety Instructions 6 victaulic.com victaulic.com 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. 3/4 − 12"/DN20 − DN300 sizes 14 − 24"/DN350 − DN600 sizes 1.0 PRODUCT DESCRIPTION Available Sizes • 3/4 – 24"/DN20 – DN600 Maximum Working Pressure • Accommodates pressures ranging from full vacuum (29.9 in Hg/760 mm Hg) up to 1000 psi/6894 kPa. • Working pressure dependent on material, wall thickness and size of pipe. Application • Joins standard roll grooved and cut grooved pipe, as well as grooved fittings, valves and accessories. • Provides a flexible pipe joint which allows for expansion, contraction and deflection. • Operating temperature dependent upon gasket and/or seal selection - see Section 3.0. • Exclusively for use with pipe and Victaulic products which feature ends formed with the Victaulic OGS groove profile (See section 7.0 for Reference Materials). Pipe Material • Carbon steel. • For use with stainless steel pipe, refer to Victaulic publication 17.09 for pressure ratings and end loads. 2.0 CERTIFICATION/LISTINGS NOTE • See publication 02.06: Victaulic Potable Water Approvals ANSI/NSF for potable water approvals if applicable. Victaulic® Standard Flexible Coupling Style 77 06.04 1 System No.Location Submitted By Date Spec Section Paragraph Approved Date 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) Standard: Orange enamel. Optional: Hot dipped galvanized and others. Optional: Contact Victaulic with your requirements for other coatings. Gasket: (specify choice1) Grade “E” EPDM EPDM (Green stripe color code). Temperature range –30ºF to +230ºF/–34ºC to +110ºC. May be specified for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73ºF/+23ºC and hot +180ºF/+82ºC potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR PETROLEUM SERVICES OR STEAM SERVICES. Grade “T” Nitrile Nitrile (Orange stripe color code). Temperature range -20ºF to +180ºF/-29ºC to +82ºC. May be specified for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not compatible for hot water services over +150ºF/+66ºC or for hot dry air over +140ºF/+60ºC. Others For alternate gasket selection, reference publication 05.01: Victaulic Seal Selection Guide - Elastomeric Seal Construction. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: (specify choice2) Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (M10-M16) Class 8.8 (M20 and greater). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - heavy hex nuts) and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 ZN/FE5, finish Type III (imperial) or Type II (metric). Optional: Stainless steel oval neck track bolts meeting the mechanical property requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel heavy hex nuts meeting the mechanical property requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling reducing coating. 2 Optional bolts/nuts are available in imperial size only. 3.0 MATERIAL SPECIFICATIONS 2 victaulic.com 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 4.0 DIMENSIONS Style 77 X ZY Z Y X 3/4 − 12"/DN20 − DN300 sizes 14 − 24"/DN350 − DN600 sizes Size Pipe End Separation3 Deflection from Centerline3 Bolt/Nut Dimensions Weight Nominal Actual Outside Diameter Allowable Per Cplg.Pipe Qty.Size X Y Z Approx. (Each) inches DN inches mm inches mm Degrees inches/ft. mm/m inches inches mm inches mm inches mm lb kg 3/4 DN20 1.050 26.7 0–0.06 0–1.6 3º–24’0.72 60 2 3/8 x 2 2.13 54 4.00 102 1.75 44 1.1 0.5 1 DN25 1.315 33.7 0–0.06 0–1.6 2º–43’0.57 48 2 3/8 x 2 2.38 61 4.12 105 1.75 44 1.2 0.5 11/4 DN32 1.660 42.2 0–0.06 0–1.6 2º–10’0.45 38 2 1/2 x 21/2 2.65 67 5.00 127 1.88 48 2.0 0.9 11/2 DN40 1.900 48.3 0–0.06 0–1.6 1º–56’0.40 33 2 1/2 x 21/2 3.13 79 5.38 137 1.88 48 2.1 1.0 2 DN50 2.375 60.3 0–0.06 0–1.6 1º–31’0.32 26 2 1/2 x 21/2 3.63 92 5.88 149 1.88 48 2.6 1.2 2.664 57.0 0–0.06 0–1.6 1º–34’0.33 27 2 1/2 x 21/2 3.43 87 5.73 146 1.90 48 3.0 1.4 21/2 2.875 73.0 0–0.06 0–1.6 1º–15’0.26 22 2 1/2 x 23/4 4.25 108 6.50 165 1.88 48 3.1 1.4 DN65 3.000 76.1 0–0.06 0–1.6 1º–12’0.26 22 2 1/2 x 23/4 4.38 111 6.63 168 1.88 48 3.2 1.5 3 DN80 3.500 88.9 0–0.06 0–1.6 1º–2’0.22 18 2 1/2 x 23/4 5.00 127 7.13 181 1.88 48 3.7 1.7 31/2 DN90 4.000 101.6 0–0.06 0–1.6 0º–54’0.19 16 2 5/8 x 31/4 5.63 143 8.25 210 1.88 48 5.6 2.5 4 DN100 4.500 114.3 0–0.13 0–3.2 1º–36’0.34 28 2 5/8 x 31/4 6.13 156 8.88 226 2.13 54 6.7 3.0 4.250 108.0 0–0.13 0–3.2 1º–41’0.35 29 2 16 x 82.5 6.00 152 8.63 219 2.13 54 11.0 5.0 5 5.563 141.3 0–0.13 0–3.2 1º–18’0.27 23 2 2– 3/4 x 41/4 7.75 197 10.65 270 2.13 54 10.6 4.8 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 3/4 – 3 1/2"/DN20 – DN90; 25% for 4"/DN100 and larger. NOTE • Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. 3 victaulic.com 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 4.0 DIMENSIONS (CONTINUED) Style 77 X ZY Z Y X 3/4 − 12"/DN20 − DN300 sizes 14 − 24"/DN350 − DN600 sizes Size Pipe End Separation3 Deflection from Centerline3 Bolt/Nut Dimensions Weight Nominal inches DN Actual Outside Diameter inches mm Allowable inches mm Per Cplg. Degrees Pipe inches/ft. mm/m Qty.Size inches X inches mm Y inches mm Z inches mm Approx. (Each) lb kg 5.250 133.0 0–0.13 0–3.2 1º–21’0.28 24 2 20 x 108 7.63 194 10.38 264 2.13 54 10.0 4.5 DN125 5.500 139.7 0–0.13 0–3.2 1º–18’0.28 24 2 20 x 108 8.63 219 10.65 270 2.13 54 10.0 4.5 6 DN150 6.625 168.3 0–0.13 0–3.2 1º–5’0.23 18 2 3/4 x 41/4 8.63 219 11.88 302 2.13 54 12.0 5.4 6.250 159.0 0–0.13 0–3.2 1º–9’0.24 20 2 20 x 108 8.63 219 11.50 292 2.13 54 13.2 6.0 6.500 165.1 0–0.13 0–3.2 1º–6’0.23 19 2 3/4 x 41/4 8.88 226 11.63 295 2.13 54 13.2 6.0 84 DN200 8.625 219.1 0–0.13 0–3.2 0º–50’0.18 14 2 7/8 x 5 11.00 279 14.75 375 2.50 63 20.8 9.4 104 DN250 10.750 273.0 0–0.13 0–3.2 0º–40’0.14 12 2 1 x 6 13.63 346 17.13 435 2.63 67 27.8 12.6 124 DN300 12.750 323.9 0–0.13 0–3.2 0º–34’0.12 9 2 1 x 61/2 15.63 397 19.25 489 2.63 67 31.1 14.1 145 DN350 14.000 355.6 0–0.13 0–3.2 0º–31’0.11 9 2 1 x 31/2 16.75 425 20.25 514 3.00 76 39.2 17.8 14.842 377.0 0–0.13 0–3.2 0º–31’0.11 9 2 1 x 31/2 17.39 442 20.96 531 2.80 71 48.8 22.1 165 DN400 16.000 406.4 0–0.13 0–3.2 0º–27’0.10 9 2 1 x 31/2 18.75 476 22.25 565 3.00 76 45 20.4 16.772 426.0 0–0.13 0–3.2 0º–27’0.10 9 2 1 x 31/2 19.69 500 22.92 581 2.92 74 56.7 25.7 185 DN450 18.000 457.2 0–0.13 0–3.2 0º–24’0.08 7 2 11/8 x 4 21.56 548 25.00 635 3.13 80 64.1 29.1 18.898 480.0 0–0.13 0–3.2 0º–24’0.08 7 2 11/8 x 4 22.38 569 25.86 655 3.04 77 77.2 35 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 3/4 – 3 1/2"/DN20 – DN90; 25% for 4"/DN100 and larger. 4 Couplings 8, 10, 12"/DN200, DN250, DN300 sizes available to JIS standards. Refer to Victaulic publication 06.17 for details. 5 For 14 – 72"/DN350 – DN1800 Roll Groove systems Victaulic offers the Advanced Groove System (AGS) line of products. Refer to Victaulic publication 20.03 for information on the Style W77 flexible AGS coupling. NOTE • Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. roll 4 victaulic.com 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 4.0 DIMENSIONS (CONTINUED) Style 77 X ZY Z Y X 3/4 − 12"/DN20 − DN300 sizes 14 − 24"/DN350 − DN600 sizes Size Pipe End Separation3 Deflection from Centerline3 Bolt/Nut Dimensions Weight Nominal inches DN Actual Outside Diameter inches mm Allowable inches mm Per Cplg. Degrees Pipe inches/ft. mm/m Qty.Size inches X inches mm Y inches mm Z inches mm Approx. (Each) lb kg 205 DN500 20.000 508.0 0–0.13 0–3.2 0º–22’0.08 7 2 11/8 x 4 23.63 600 27.00 686 3.13 80 74.8 34 225 DN550 22.000 559.0 0–0.13 0–3.2 0º–19’0.07 6 2 11/8 x 4 25.63 651 29.13 740 3.13 80 82.6 37.5 20.866 530.0 0–0.13 0–3.2 0º–22’0.08 7 2 11/8 x 4 24.29 617 27.80 704 3.07 77 91.7 41.6 22.835 580.0 0–0.13 0–3.2 0º–19’0.07 6 2 11/8 x 4 26.76 680 30.01 762 3.12 79 92.8 42.2 245 DN600 24.000 609.6 0–0.13 0–3.2 0º–18’0.07 6 2 11/8 x 4 27.75 705 31.00 787 3.19 81 89.6 40.7 24.803 630.0 0–0.13 0–3.2 0º–18’0.07 6 2 11/8 x 4 28.42 722 32.16 817 3.12 79 96.8 44 14–72 DN350– DN1800 AGS See Style W77, refer to Victaulic publication 20.03 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 3/4 – 3 1/2"/DN20 – DN90; 25% for 4"/DN100 and larger. 5 For 14 – 72"/DN350 – DN1800 Roll Groove systems Victaulic offers the Advanced Groove System (AGS) line of products. Refer to Victaulic publication 20.03 for information on the Style W77 flexible AGS coupling. NOTE • Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. 5 victaulic.com 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE Style 77 Size Working Pressure6 End Load6 Nominal Actual Outside Diameter Maximum Maximum inches DN inches mm psi kPa lb N 3/4 DN20 1.050 26.7 1000 6894 865 3,850 1 DN25 1.315 33.4 1000 6894 1360 6,050 11/4 DN32 1.660 42.2 1000 6894 2160 9,610 11/2 DN40 1.900 48.3 1000 6894 2835 12,615 2 DN50 2.375 60.3 1000 6894 4430 19,715 2.664 57.0 1000 6894 3955 17,592 21/2 2.875 73.0 1000 6894 6490 28,880 DN65 3.000 76.1 1000 6894 7070 31,460 3 DN80 3.500 88.9 1000 6894 9620 42,810 31/2 DN90 4.000 101.6 1000 6894 12565 55,915 4 DN100 4.500 114.3 1000 6894 15900 70,755 4.250 108.0 1000 6894 14180 63,100 5 5.563 141.3 1000 6894 24300 108,135 6 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. NOTE • WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. 6 victaulic.com 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE (CONTINUED) Style 77 Size Working Pressure6 End Load6 Nominal Actual Outside Diameter Maximum Maximum inches DN inches mm psi kPa lb N 5.250 133.0 1000 6894 21635 96,275 DN125 5.500 139.7 1000 6894 23745 105,665 6 DN150 6.625 168.3 1000 6894 34470 153,390 6.250 159.0 1000 6894 30665 136,460 6.500 165.1 1000 6894 33185 147,660 84 DN200 8.625 219.1 800 5515 46740 207,995 104 DN250 10.750 273.0 800 5515 73280 326,100 124 DN300 12.750 323.9 800 5515 102000 453,900 145 DN350 14.000 355.6 300 2068 46180 205,500 14.842 377.0 300 2068 51875 230,845 165 DN400 16.000 406.4 300 2068 60320 268,425 16.772 426.0 300 2068 66245 294,795 185 DN450 18.000 457.2 300 2068 76340 339,710 18.898 480.0 300 2068 84105 374,265 205 DN500 20.000 508.0 300 2068 94000 418,300 225 DN550 22.000 559.0 300 2068 114000 507,300 20.866 530.0 300 2068 102535 456,280 22.835 580.0 300 2068 102380 455,591 245 DN600 24.000 609.6 250 1723 113000 502,850 24.803 630.0 250 1723 102790 457,416 14–72 DN350–DN1800 AGS See Style W77, refer to Victaulic publication 20.03 4 Couplings 8, 10, 12"/DN200, DN250, DN300 sizes available to JIS standards. Refer to Victaulic publication 06.17 for details. 5 For 14 – 72"/DN350 – DN1800 Roll Groove systems Victaulic offers the Advanced Groove System (AGS) line of products. Refer to Victaulic publication 20.03 for information on the Style W77 flexible AGS coupling. 6 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. NOTE • WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. 7 victaulic.com 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products Victaulic products for a particular end-use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications, and the applicable building codes and related Victaulic reserves the right to change product specifications, designs and standard regulations as well as Victaulic performance, maintenance, safety, and warning equipment without notice and without incurring obligations. instructions. Nothing in this or any other document, nor any verbal recommendation, Installationadvice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale, installation instructions of the product you are installing. Handbooks are included with each shipment guide, or this disclaimer.of Victaulic products, providing complete installation and assembly data, and are available Intellectual Property Rights in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warrantyproduct, service, or design is intended, or should be constructed, to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details.under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such Trademarks material, product, service, or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right. The terms “Patented” or “Patent Pending” refer to design or utility patents Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. 6.0 NOTIFICATIONS • For 14 – 72"/DN350 – DN1800 flexible roll groove systems, Victaulic recommends Style W77 AGS couplings. For more information, refer to Victaulic publication 20.03. WARNING • Victaulic RX roll sets must be used when grooving light-wall/thin-wall stainless steel pipe for use with Victaulic Couplings. Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure, resulting in serious personal injury and/or property damage. NOTICE • Victaulic RX grooving rolls must be ordered separately. They are identified by a silver color and the designation RX on the front of the roll sets. 7.0 REFERENCE MATERIALS I-100: Victaulic Field Installation Handbook 02.06: Victaulic Potable Water Approvals ANSI/NSF 05.01: Victaulic Seal Selection Guide 06.15: Victaulic Pressure Ratings and End Loads for Victaulic® Couplings on Steel Pipe 06.17: Victaulic Couplings and Fittings for JIS Pipe 10.01: Victaulic Products for Fire Protection Piping Systems - Regulatory Approval 17.01: Victaulic Pipe Preparation for Use on Stainless Steel Pipe With Victaulic Products 17.09: Victaulic Ductile Iron Grooved Couplings Performance Data for Stainless Steel Pipe 20.03: Victaulic AGS Flexible Coupling Style W77 25.01: Victaulic Original Groove System (OGS) Groove Specifications 26.01: Victaulic Design Data 26.04: Victaulic Couplings Vibration Attenuation Characteristics 29.01: Victaulic Terms and Conditions of Sale I-ENDCAP: Victaulic End Caps Installation Instructions 8 victaulic.com Job Name:Contractor: Location:Quantity: Engineer:Date: TEL: 714-919-7814 FAX: 714-464-5474 Features * Manufactured According to ASTM A795 * ERW, Grade A, Type E * Meets NFPA 13 * Plain Ends or Grooved Ends * Corrosion Resistant Surface * Mill Lacquer Coated * 300 PSI Rated * UL List & FM Approved Specification Pipe Mill: MS Pipe Country of Origin: South Korea Nominal Pipe Size: 1-1/4" to 4" Length: 21 Feet Empty WFW** Size O.D.I.D.Lbs/Ft Lbs/Ft Pcs/Lft CRR* 1-1/4"1.660"1.494"1.399 2.194 61 3.70 1-1/2"1.900"1.710"1.833 2.875 61 4.42 2"2.375"2.185"2.315 4.016 37 3.58 2-1/2"2.875"2.709"2.477 5.092 30 1.37 3"3.500"3.320"3.281 7.207 19 1.27 4"4.500"4.298"4.750 11.330 19 1.10 *CRR=Corrosion Resistance Ratio Calculated Using UL CRR Formula Under UL Category VIZY. This Ratio Value Is Used to Measure the Ability of A Pipe to Withstand Corrosion. **WFW=Water Filled Weight Steel Pipe Super Flow www.akwsupply.com AKW Supply Co.product specifications and dimensions are approximate and are provided for reference only.It's the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of our products.AKW Supply Co.reserves the right to change or modify product design,construction,specification,model number or material without prior notice and without incurring any obligation to make such changes on AKW Supply Co. previously sold. SUBMITTAL SHEET Job Name:Contractor: Location:Quantity: Engineer:Date: TEL: 714-919-7814 FAX: 714-464-5474 Features * Manufactured According to ASTM A53 * Sch 10, ERW, Grade A, Type E * Plain Ends or Grooved Ends * Black Color * Paint Coating * UL List & FM Approved Chemical Composition (Max. %) C Mn P S 0.25 0.95 0.05 0.045 Tensile Strength (Min. Psi) Yield Tensile 30,000 48,000 Specification Pipe Brand: STS Country of Origin: Thailand Nominal Pipe Size: 1-1/4" to 6" Length: 21 Feet Size O.D.I.D.Lbs/Ft Test Pressure PCS/Bundle 1-1/4"1.660"1.442"1.810 1,000 Psi 61 1-1/2"1.900"1.682"2.090 1,000 Psi 61 2"2.375"2.157"2.640 1,000 Psi 37 2-1/2"2.875"2.635"3.530 1,000 Psi 19 3"3.500"3.260"4.340 1,000 Psi 19 4"4.500"4.260"5.620 1,200 Psi 19 6"6.625"6.357"9.300 1,000 Psi 7 Steel Pipes SCH 10 www.akwsupply.com AKW Supply Co.product specifications and dimensions are approximate and are provided for reference only.It's the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of our products.AKW Supply Co.reserves the right to change or modify product design,construction,specification,model number or material without prior notice and without incurring any obligation to make such changes on AKW Supply Co. previously sold. SUBMITTAL SHEET Job Name:Contractor: Location:Quantity: Engineer:Date: TEL: 714-919-7814 FAX: 714-464-5474 Features * Manufactured According to ASTM A53 * Sch 40, ERW, Grade A, Type E * Plain Ends or Threaded & Coupled * Black or Galvanized * Varnished Coating Chemical Composition (Max. %) C Mn P S Residual 0.25 0.95 0.05 0.045 Note 1 Note 1: Residual Elements Cu (0.4), Ni (0.4), Cr (0.4), Mo (0.15), and V (0.08) Combined Shall Not Exceed 1%. Tensile Strength (Min. Psi) Yield Tensile 30,000 48,000 Specification Brand: STS Country of Origin: Thailand Nominal Pipe Size: 1/2" to 2" NPT Length: 10 Feet to 21 Feet Size O.D.I.D.Lbs/Ft Test Pressure PCS/Bundle 1/2"0.840"0.622"0.850 700 Psi 127 3/4"1.050"0.824"1.130 700 Psi 91 1"1.315"1.049"1.680 700 Psi 61 1-1/4"1.660"1.380"2.270 1,200 Psi 61 1-1/2"1.900"1.610"2.720 1,200 Psi 61 2"2.375"2.067"3.660 2,300 Psi 37 Steel Pipes SCH 40 www.akwsupply.com AKW Supply Co.product specifications and dimensions are approximate and are provided for reference only.It's the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of our products.AKW Supply Co.reserves the right to change or modify product design,construction,specification,model number or material without prior notice and without incurring any obligation to make such changes on AKW Supply Co. previously sold. SUBMITTAL SHEET Sammys® for Wood .......................................................................................................................... 4 Sidewinder® for Wood ....................................................................................................................... 5 Sammys Swivel Head™ for Wood ......................................................................................................5 Sammys® for Steel ............................................................................................................................ 6 Sidewinder® for Steel ........................................................................................................................ 7 Sammys Swivel Head™ for Steel .......................................................................................................7 Sammy X-Press® ...............................................................................................................................8 Sammy X-Press Sidewinder™ ............................................................................................................8 Sammy X-Press Swivel™ ...................................................................................................................9 Sammy X-Press It® Installation Tool ..................................................................................................9 Sammys® for Concrete ................................................................................................................... 10 Sidewinder® for Concrete ................................................................................................................10 Sammys Swivel Head™ for Concrete ................................................................................................11 Concrete/Wood Installation Kit ........................................................................................................ 11 Sammys Toggle™ ............................................................................................................................ 12 Ceiling Screws .................................................................................................................................12 Dektite® Pipe Flashing .....................................................................................................................13 Speedy Pole Tool™.......................................................................................................................... 13 Spot Rite Level™ ..............................................................................................................................13 Approvals and Listings ....................................................................................................................14 Special Notes ..................................................................................................................................15 TABLE OF CONTENTS Warranty • Disclaimer of Warranty Proper fastener connection design takes in to account where and how fasteners are used. Allowance for special characteristics in materials, differences in materials, differences in types of materials being joined, unique or unusual environmental service or installation conditions and the safety factors required by anticipating normal or short term loading conditions must be considered. Due to possible differences in specifications, applications, and interpretation of results, purchasers and specifiers must make their own evaluation of the products, to determine the suitability of these products for intended use. All warranties of Buildex products, expressed or implied, including the warranties of merchantabilty and fitness for particular purposes are specifically excluded except for the following: Buildex will repair or replace any product which, within twelve months after sale by Buildex or its distributors, is found by Buildex to be defective in material or workmanship - normal wear and tear accepted. This is the sole warranty of Buildex and the sole remedy available to distributor or buyer. Buildex shall not be liable for any injury, loss or damage, direct, indirect, or consequential, arising out of the use of, or the inability to use, any Buildex product. For the most up to date information, visit www.itwbuildex.com 3 To find a distributor near you, call 800-BUILDEX INSTALLATION STEPS - VERTICAL INTO CONCRETE: 1. Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2” with a hammer/rotary hammer drill set on impact mode. 2. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). 3. Insert the CST screw into the nut driver. 4. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. 5. The concrete screw is ready to receive 1/4”, 3/8”, 1/2”, or metric all thread rod or bolt stock. (#14SW red nut driver used with 1/2” screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode — doing so will destroy the pullout factor of the screw. INSTALLATION STEPS - HORIZONTAL INTO CONCRETE: 1. Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2” with a hammer/ rotary hammer drill set on impact mode. 2. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14SW (red) nut driver (p/n 8114910) into the opposite end. 3. Insert the SWC screw into the nut driver. 4. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. 5. The SWC screw is ready to receive 1/4”, 3/8” or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode — doing so will destroy the pullout factor of the fastener. INSTALLATION INSTRUCTIONS FOR CONCRETE SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. INSTALLATION STEPS - VERTICAL INTO WOOD & STEEL: 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 2. Insert the SAMMYS® into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. 3. Push the face of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. 4. The SAMMYS is now ready to receive 1/4”, 3/8”, 1/2” or metric all thread rod, bolt stock. (The 1/2” requires the #14SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximumpullout in purlin steel. INSTALLATION STEPS - HORIZONTAL INTO WOOD & STEEL: 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 2. Insert the SAMMYS into the #14SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. 3. When the nut driver spins freely on the SAMMYS, stop the drill and remove. 4. The unit is now ready to receive 1/4”, 3/8”, M10, M8 or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. INSTALLATION INSTRUCTIONS FOR WOOD & STEEL 4 For the most up to date information, visit www.itwbuildex.com Wood Flooring Wood Joist Double Sheetrock Ceiling Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Box Qty Case Qty VERTICAL MOUNT 1/4"8002957 GST 100 1/4 x 1"210 (7/16” OSB) 670 (3/4” Ply)25 125 1/4"8003957 GST 200 1/4 x 2"1760 (Fir)25 125 3/8"8007957 GST 10 1/4 x 1"210 (7/16” OSB) 670 (3/4” Ply)300 25 125 3/8"8008957 GST 20 1/4 x 2"1760 (Fir)850 1475 25 125 3/8"8068925 GST 20-SS 1/4 x 2"1760 (Fir)850 25 125 3/8"8009925 GST 25-380 3/8 x 2-1/2"2113 (Fir)1500 25 125 3/8"8010957 GST 30 1/4 x 3"2060 (Fir)1500 1475 25 125 3/8"8069925 GST 30-SS 1/4 x 3"2060 (Fir)25 125 1/2"8013925 GST 2 1/4 x 2"1760 (Fir)25 125 1/2"8015925 GST 3 1/4 x 3"2275 (Fir)25 125 Not less than 2” nominal width (1-1/2”) Not less than 3” nominal thickness (2-1/2”) (depth or side of vertical member) #14 Black Nut Driver Part # 8113910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. #14 SW Red Nut Driver Part # 8114910 Composite / Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for GST 25-380 . Tool available on page 11. For vertical use - install in center of lower face. Minimum 2” embedment into base material for NFPA 13 compliance. • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation costs. • Manufactured in the U.S.A. SAMMYS® FOR WOOD Application Product Features Watch a video demonstration atwww.itwbuildex.com SAMMYS® FOR WOOD - Vertical Application MANUFACTURED U.S.A. 5 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETENot less than 2” nominal width (1-1/2”) up to 3-1/2” pipe; not less than 3” (2-1/2”) nominal width 4” & 5” pipe Minimum 2-1/2” from bottom for branch lines. Minimum 3” from bot- tom for main lines. Exception: This requirement shall not apply to 2” or thicker nailing strips resting on top of steel beams. Floor Joist Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) Box Qty Case Qty HORIZONTAL MOUNT 1/4"8019957 SWG 200 1/4 x 2"1725 (Fir)25 125 3/8"8020957 SWG 10 1/4 x 1"622 (Fir)300 25 125 3/8"8021957 SWG 20 1/4 x 2"1725 (Fir)1050 25 125 3/8"8073925 SWG 20-SS 1/4 x 2"1725 (Fir)850 25 125 3/8"*8022925 SWG 25-380 3/8 x 2-1/2"2249 (Fir)1500 25 125 3/8"8023925 SWG 30 1/4 x 3"1884 (Fir)25 125#14 SW Red Nut Driver Part # 8114910 • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation costs. • Manufactured in the U.S.A. Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thickness Box Qty Case Qty SWIVEL MOUNT 3/8"8139957 SH-GST 20 1/4 x 2"1257 (Fir)1050 1475 25 125 3/8"*8269957 SH-GST/CST 20 5/16 x 1-3/4” 1903 Dim. Lumber 1406 @ 45°off vertical Dim. Lumber 1500 850 @ 45°25 125 1/2”8303957 SH-GST/CST 2.0 5/16 x 1-3/4” 903 Dim. Lumber 1406 @ 45°off vertical Dim. Lumber 25 125 #14 Black Nut DriverPart # 8113910 • Eliminates distortion of threaded rod. • Accommodates up to 3 ½” x 12 pitch roof. • Allows 17° deflection from vertical. • Saves time from traditional methods. • Reduces installation costs. • Manufactured in the U.S.A. Application Product Features Application Product Features Composite / Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for Model SWG 25-380. Tool available on page 11. Watch a video demonstration atwww.itwbuildex.com SIDEWINDER® FOR WOOD - Horizontal Application SAMMYS SWIVEL HEAD™ FOR WOOD - Swivel Application #14 SH Orange Nut DriverPart # 8273910 * May require pre-drilling; consult joist manufacturer. * May require pre-drilling; consult joist manufacturer. 6 For the most up to date information, visit www.itwbuildex.com Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thick Max Thick Box Qty Case Qty VERTICAL MOUNT 1/4"8024957 DSTR 100 *1/4-20 x 1" TEKS 3 1510 (20 ga.).036"-20 ga 3/16"25 125 1/4"8025957 DST 100 1/4-14 x 1" TEKS 3 446 (20 ga.).036"-20 ga 3/16"25 125 1/4"8026957 DST 150 1/4-14 x 1-1/2" TEKS 3 970 (16 ga.).036"-20 ga 3/16"25 125 1/4"8027957 DST 200 1/4-14 x 2" TEKS 3 446 (20 ga.).036”-20 ga 3/16”25 125 1/4"8030957 TEK 500 12-24 x 1-1/2" TEKS 5 3125 (3/16").188”-3/16”1/2"25 125 3/8"8038957 DSTR 1 *1/4-20 x 1" TEKS 3 1510 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8037957 DSTR 1-1/2 *12-24 x 1-1/2" TEKS 5 1510 (3/16")1500 1475 .060”-16 ga.1/2"25 125 3/8"8039957 DSTR 516 *5/16-18 x 1-1/4" TEKS 3 2200 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8040957 DST 10 1/4-14 x 1" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8077925 DST 10-SS 1/4-14 x 1" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8041957 DST 15 1/4-14 x 1-1/2" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8078925 DST 15-SS 1/4-14 x 1-1/2" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8042957 DST 20 1/4-14 x 2” TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8044957 DST 30 1/4-14 x 3" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8045957 DST 516 5/16-18 x 1-1/4" TEKS 3 1500 (3/16")1500 1475 .125"-1/8"3/16"25 125 3/8"8046957 TEK 50 12-24 x 1-1/2" TEKS 5 3125 (3/16")1500 1475 .250”-1/4”1/2"25 125 1/2"8031925 DST 2.0 1/4-14 x 2" TEKS 3 446 (20 ga.) 970 (16 ga.).188"-3/16"1/4"25 125 1/2"8033925 DSTR 1.0 *1/4-20 x 1" TEKS 3 1510 (20 ga.).036"-20 ga 3/16"25 125 1/2"8034925 DSTR 5.16 *5/16-18 x 1-1/4" TEKS 3 2220 (20 ga.).036"-20 ga 3/16"25 125 1/2"8035925 DST 5.16 5/16-18 x 1-1/4" TEKS 3 1500 (3/16").125"-1/8"3/16”25 125 1/2"8036925 TEK 5.0 12-24 x 1-1/2" TEKS 5 3125 (3/16").188"-3/16"1/2"25 125 #14 Black Nut Driver Part # 8113910 #14 SW Red Nut Driver Part # 8114910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. • Made with Teks® self-drilling fasteners - no pre-drilling required. • Installs into steel range from 20 gauge – 1/2” thicknesses. • Saves time from traditional methods. • Reduces installation costs. • Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. • A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. • Manufactured in the U.S.A. SAMMYS® FOR STEEL Watch a video demonstration atwww.itwbuildex.com Application Product Features SAMMYS® FOR STEEL - Vertical Application *Includes retaining nut MANUFACTURED U.S.A. 7 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETEApprovals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thick Max Thick Box Qty Case Qty SWIVEL MOUNT 3/8"8137957 SH-DSTR 1*1/4-20 X 1” TEKS 3 3220 (3/16”)1500 1475 .035”3/16”25 125 3/8"8268957 SH-TEK 50 12-24 x 1-3/4" TEKS 5 2368 (1/2" steel Vertical) 1306 (45° off Vertical) 2281 (3/16” HSS) 1585 (3/16” HSS 45° off Vertical) 1500 (Vertical) 850 (45° off Vertical) 4" 2-1/2” 3/16"1/2"25 125 1/2”8270957 SH-TEK 5.0 12-24 x 1-3/4” TEKS 5 2368 (1/2” steel Vertical) 1306 (45° off Vertical) 2281 (3/16” HSS) 1585 (3/16” HSS 45° off Vertical) 3/16"1/2"25 125 #14 Black Nut DriverPart # 8113910 Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thickness Max Thickness Box Qty Case Qty HORIZONTAL MOUNT 1/4"8047957 SWD 100 1/4-14 x 1" TEKS 3 1477 (16 ga.).060"-16 ga 3/16"25 125 1/4"8049957 SWDR 100 *1/4-20 x 1" TEKS 3 1900 (20 ga.).036"-20 ga 3/16"25 125 3/8"8050957 SWD 10 1/4-14 x 1" TEKS 3 1477 (16 ga.).060"-16 ga 3/16"25 125 3/8"8080925 SWD 10-SS 1/4-14 x 1" TEKS 3 1477 (16 ga.).060"-16 ga 3/16"25 125 3/8"8052957 SWD 20 1/4-14 x 2" TEKS 3 1477 (16 ga.).060"-16 ga 3/16”25 125 3/8"8055957 SWDR 1 *1/4-20 x 1" TEKS 3 1900 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8054957 SWDR 1-1/2 *12-24 x 1-1/2" TEKS 5 2375 (3/16")1500 1475 .188"-3/16"1/2"25 125 3/8"8056957 SWDR 516 *5/16-18 x 1-1/4" TEKS 3 2480 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8057957 SWT 15 12-24 x 1-1/2" TEKS 5 2375 (3/16").188"-3/16"1/2"25 125 #14 SW Red Nut Driver Part # 8114910 *Includes retaining nut • Made with Teks® self-drilling fasteners - no pre-drilling required. • Installs into steel range from 20 gauge – 1/2” thicknesses. • A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. • Saves time from traditional methods. • Reduces installation costs. • Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. • Manufactured in the U.S.A. • Eliminates distortion of threaded rod in sloped roof applications. • Accommodates 3-1/2 x 12 pitch. • Installs into angled z-purlin; allows threaded rod to hang plumb. • Allows 17° deflection from vertical. • Manufactured in the U.S.A. *Does not comply with ROHS requirements / Includes retaining nut Application Product Features SAMMYS SWIVEL HEAD™ FOR STEEL - Swivel Application SIDEWINDER® FOR STEEL - Horizontal Application Application Product Features #14 SH Orange Nut DriverPart # 8273910 Watch a video demonstration atwww.itwbuildex.com Watch a video demonstration atwww.itwbuildex.com 8 For the most up to date information, visit www.itwbuildex.com SAMMY X-PRESS® - Vertical Application Approvals Rod Size Part Number Model Description Ultimate Pullout (lbs) UL Test Load (lbs) UL Min Thick FM Test Load (lbs) FM Min Thick Max Thick Box Qty Case Qty Application VERTICAL MOUNT 1/4"8181922 XP 200 Sammy X-Press 200 1146 (22 ga)185 (Luminaire) 250 (Luminaire) .027" .056”.125”25 125 Metal Deck 3/8"8150922 XP 20 Sammy X-Press 20 1146 (22 ga) 850 (2½" Pipe) 185 (Luminaire) 250 (Luminaire) 283 (Conduit & Cable) .027" .027” .056” .029” 940 (2" Pipe) 1475 (4” Pipe) .029” .104” .125”25 125 Metal Deck 3/8"8153922 XP 35 Sammy X-Press 35 1783 (16 ga) 1500 (4" Pipe) 185 (Luminaire) 250 (Luminaire) 416 (Conduit & Cable) .060” .029” .056” .059” 940 (2" Pipe) 1475 (4” Pipe) .029” .104”.125”25 125 Purlin 3/8"8150922 XP 20 Sammy X-Press 20 1146 (22 ga)850 (2½ Pipe) Pre-Pour Structural Concrete@ 3000 psi Post-Pour Range II LWC≤ 35 PCF (lbs/ft³) 25 125 Metal Deck (Pre-Pour) Metal Deck (Post-Pour) SAMMY X-PRESS® Post-Pour Range II LWC≤ 35 PCF (lbs/ ft³) Pre-Pour Structural Concrete @ 3000 psi Installs into Metal Deck, Purlin, or Tubular Steel • The Sammy X-Press expands to provide direct vertical attachment in: - light gauge steel deck or purlin (22 ga. - 1/8”). • Installs in seconds with Sammy X-Press It® Tool, saving time & installation costs. • Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A. Watch a video demonstration atwww.itwbuildex.com Application Product Features • The Sammy X-Press Sidewinder expands to provide horizontal attachment in: - 16 ga - 3/16” steel - purlin, tubular steel. • Installs in seconds with Sammy X-Press It® Tool, saving time & installation costs. • Use in applications where access to the back of the installed fastener is prohibited; ie. metal roof deck, tubular steel, or vapor barrier fabric. • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A. (SWXP) Approvals Rod Size Part Number Model Description Ultimate Pullout (lbs) UL Test Load (lbs) UL Min Thick FM Test Load (lbs) Max Thick Box Qty Case Qty Application HORIZONTAL MOUNT 3/8"8293957 SWXP 35 Sidewinder X-Press 35 1798 (16 ga) 1250 (3½" Pipe) 80 (Luminaire) 416 (Conduit & Cable) .059”.125”25 125 Purlin Watch a video demonstration atwww.itwbuildex.com Application Product Features SAMMY X-PRESS SIDEWINDER™ - Horizontal Application (XP) MANUFACTURED U.S.A. 9 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETE• The Sammy X-Press Swivel allows you to hang plumb in extreme roof pitches: - 89° in z-purlin - 45° in metal deck for 12/12 pitch • Installs in seconds with Sammy X-Press It® Tool, saving time & installation costs. • Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A.(SXP) Installs into Metal Deck, Purlin, or Tubular Steel Approvals Rod Size Part Number Model Description Ultimate Pullout (lbs) UL Test Load (lbs) UL Min Thick FM Test Load (lbs) FM Min Thick Max Thick Box Qty Case Qty Application SWIVEL MOUNT 3/8”8294922 SXP 20 Swivel X-Press 20 1061 (22 ga Vert) 829 (45° Off Vert) 750 (2” Pipe) 170 Vertical (Luminaire) 80 @ 45° (Luminaire) 283 Vertical (Conduit & Cable) 233 @ 45° (Conduit & Cable) .029” 635 (2” Pipe).029”.125”25 125 Metal Deck 3/8"8295922 SXP 35 Swivel X-Press 35 1675 (16 ga Vert) 1558 (89° Off Vert) 1250 (3-1/2" Pipe) 250 Vertical (Luminaire) 80 @ 90° (Luminaire) 500 Vertical (Conduit & Cable) 333 @ 89° (Conduit & Cable) .059” 635 (2" Pipe).029”.125”25 125 Purlin 1/2”8272957 SXP 2.0 Swivel X-Press 2.0 1061 (22 ga Vert) 829 (45° Off Vert).027” .125”25 125 Metal Deck 1/2"8271957 SXP 3.5 Swivel X-Press 3.5 1675 (16 ga Vert) 1558 (89° Off Vert).060".125”25 125 Purlin • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A. Watch a video demonstration atwww.itwbuildex.com Application Product Features *Tool Includes: Sleeve, Bit Receiver, Hex Wrench, and 25/64” Drill Bit. Part Number Model Description Qty 8194910 UXPIT*Universal X-Press It Tool 1 8152910 XPDB 25/64" Drill Bit 1 SAMMY X-PRESS IT® Installation Tool • The Sammy X-Press expands to provide direct vertical attachment in: - metal deck (22-16 gauge) - z-purlin (18-16 gauge) • Manufactured in the U.S.A. Watch a video demonstration atwww.itwbuildex.com Application Product Features • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A. SAMMY X-PRESS SWIVEL™ - Swivel Application 10 For the most up to date information, visit www.itwbuildex.com SAMMYS® FOR CONCRETE - Vertical Application Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs)* FM Test Load (lbs) Box Qty Case Qty VERTICAL MOUNT 1/4"8058957 CST 200 5/16 x 1-3/4"2400 25 125 3/8"8059957 CST 20 5/16 x 1-3/4"2400 1475 25 125 3/8"8145925 CST 20-SS 5/16 x 1-3/4"2400 25 125 1/2"8060925 CST 2 5/16 x 1-3/4"2400 25 125 #14 BlackNut DriverPart # 8113910 #14SW Red Nut DriverPart # 8114910 • Easy two step process (Drill hole & drive Sammys concrete anchor). • ¼” pre-drilled pilot hole required. • Concrete Installation Tool available for a one tool installation process. • Manufactured in the U.S.A. * Tested in 3000 PSI concrete Application Product Features SAMMYS® FOR CONCRETE Watch a video demonstration atwww.itwbuildex.com SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs)* FM Test Load (lbs) Box Qty Case Qty HORIZONTAL MOUNT 1/4"8062957 SWC 200 5/16 x 1-3/4"2450 25 125 3/8"8061957 SWC 20 5/16 x 1-3/4"2450 1475 25 125 #14SW Red Nut DriverPart # 8114910 • Easy two step process (Drill hole & drive Sammys concrete anchor). • ¼” pre-drilled pilot hole required. • Concrete Installation Tool available for a one tool installation process. • Manufactured in the U.S.A. * Tested in 3000 PSI concrete Application Product Features Watch a video demonstration atwww.itwbuildex.com SIDEWINDER® FOR CONCRETE - Horizontal Application MANUFACTURED U.S.A. 11 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETE(a) or (g)(d)(h) (b) (c) Rotary Hammer Drill into concrete Part Number Description Each Qty 8122910 Concrete Installation Kit (a) Kit includes the following items: 8113910 #14 Black Nut Driver (b)1 8114910 #14 SW Red Nut Driver (c)1 8116910 #250 Bit (1/4") (d)1 8117910 SDS Bit (1/4") (e)1 8118910 7/32 Wood Bit (f)1 8120910 HEX 250 Bit Receiver (1/4") (g)1 8098910 SL 250 Sleeve (h)1 8121910 SDS B250 Bit Receiver (1/4”)*1 *Only sold separately - not included in kit. or (e)(h) (b) (c) Hammer Drill into concrete Application CONCRETE / WOOD INSTALLATION KIT Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs)* Box Qty Case Qty SWIVEL MOUNT 3/8"8269957 SH-GST/CST 20 5/16 x 1-3/4" 2537 in 3000 psi concrete 1459 @ 45°off vertical in 3000 psi concrete 2852 in 6000 psi concrete 1636 @ 45°off vertical in 6000 psi concrete 25 125 1/2”8303957 SH-GST/CST 2.0 5/16 x 1-3/4" 2537 in 3000 psi concrete 1459 @ 45°off vertical in 3000 psi concrete 2852 in 6000 psi concrete 1636 @ 45°off vertical in 6000 psi concrete 25 125 * Tested in 3000 PSI concrete Application Product Features #14 SH Orange Nut DriverPart # 8273910 SAMMYS SWIVEL HEAD™ FOR CONCRETE - Swivel Application • Installs vertically and swivels up to 89° in wood & concrete structures. • Eliminates distortion of threaded rod. • 1/4” pre-drilled pilot hole required. • Concrete installation tool available for a one piece installation process. • Manufactured in the U.S.A. Note: UL Listed for wood - see page 5 12 For the most up to date information, visit www.itwbuildex.com SAMMY TOGGLE for Drywall/Concrete Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs)Box Qty Case Qty 1/4"8063925 SST 300 1/4 x 3"450 (Lath & Plaster) 404 (2 Layers 5/8 Rock)25 125 3/8"8064925 SST 30 1/4 x 3"450 (Lath & Plaster) 404 (2 Layers 5/8 Rock)25 125#14 Black Nut DriverPart # 8113910 Pre-Cast Hollow Core Concrete 1. Pre-drill a 5/8” hole with a regular drill or hole saw. 2. Insert SST screw into #14 black nut driver. With wing nut and washer on bolt, insert wing nut through surface, and begin installation. 3. When bolt is secure and nut driver spins free, stop drill motor and remove. 4. SST screw is now ready to receive 1/4”, 3/8”, or Metric all thread rod or bolt stock. Approvals Substrate Part Number Model Point Description Overal Total Length Ultimate Pullout (lbs) Max Gauge ICC Test Load (lbs) Box Qty Case Qty ICC STEEL 8107957 CWSD 1*Teks 1/4 x 1"2”472 (20 ga)16 ga.170 (20 ga.)25 125 ICC STEEL WOOD 8190957 CWSD 15*Gimlet Teks 1/4 x 1-1/2"2-3/4”472 (20 ga) 1393 (Fir)20 ga.170 (20 ga.)25 125 ICC STEEL 8108957 CWSD 2*Teks 1/4 x 2"3-1/4”472 (20 ga)16 ga.170 (20 ga.)25 125 ICC 8110910 CWIT Installation Tool 1CWIT Installation ToolPart # 8110910 Use the Speedy Pole Tool™ for easy installation of ceiling screws without ladders or scaffolding! (see pg 13 for details) • 3/16” eyelet to accommodate common wire size. • ICC approvals can be found at www.itwbuildex.com under Evaluation Report # ER-5367. * Does not comply with ROHS requirements Application Installation Steps Application Product Features CEILING SCREWS SAMMYS TOGGLE™ ACCESSORIES To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETE13 Part Number Model Ea. Qty 8130910 Spot Rite Level 1 • 1/2”, 3/4”, and 1” threading • Magnetic strip for ease of use • Pocket Sized • Lightweight • 3-vial design for measurement of 0º, 45º, and 90º angles • Complies with NFPA 13 Code Changes. • Flashing for dry pendant sprinklers subject to extreme temperature changes. • One piece construction is easy to install. • Pipe diameter markings ensure accurate fit. • EPDM temperature range of -65°F to +250°F. Part Number Description Pipe Outside Diameter Dektite Base Diameter Dektite Height Box Qty 4001910 Mini 1/4” - 1-1/8”3-1/2”1-3/4”20 4003910 1 1/4” - 2”4-3/4”3”10 4004910 2 1-3/4” - 3-1/4”6-1/4”4”10 DEKTITE® PIPE FLASHING Application Product Features SPOT-RITE LEVEL™ (Items not sold seperately) Product Features • The Pole Tool and Universal Socket Kit provide easy and safe installation for: - Sammys - Jack Chain - Threaded Rod - Wire - Pencil Rod - Screws - Ceiling Screws • Ideal for retrofit and hard-to-reach projects in wood and steel. Part Number Description Box Qty 8123910 Pole Tool 6' (3' - 6')1 8124910 Pole Tool 12' (4' - 12')1 8125910 Pole Tool 18' (6' - 18')1 8126910 Pole Tool 24' (8' - 24')1 Speedy Pole Tool Installation (specify choice when ordering pole tool) 8127910 Sammys Socket Driver 1 8128910 Ceiling Wire Socket Driver for wire and chain 1 8129910 Universal Pole Tool Socket Kit 1 • Adaptor Plug (a) • Socket Driver for SAMMYS (b) • Socket Driver for Ceiling Wire Screws (c) • Socket Driver for 1/4” Standard Nut Drivers (d) • Stud Plug for Viper or Ladd Powder Actuated Attachment (e)(c) (b) (d) (e)(a) SPEEDY POLE TOOL™ & UNIVERSAL SOCKET KIT Universal Pole Tool Socket Kit (8129910) Includes:Product Features Watch a video demonstration atwww.itwbuildex.com Part Number Model Rod Size Mount Direction UL Max Pipe Size UL Test Load (lbs)UL Min Wood Thickness FM Max Pipe Size FM Test Load (lbs)FM Min Wood Thickness SAMMYS FOR WOOD - PIPE HANGER 8007957 GST 10 3/8”Vertical CPVC 1-1/2”300 1-1/2” 8020957 SWG 10 3/8”Horizontal CPVC 1-1/2”300 1-1/2” 8008957 GST 20 3/8”Vertical 2-1/2”850 1-1/2”4”1475 1-1/2” 8068925 GST 20-SS 3/8”Vertical 2-1/2”850 1-1/2” 8010957 GST 30 3/8”Vertical 4”1500 1-1/2”4”1475 1-1/2” 8009925 GST 25-380 3/8”Vertical 4”1500 1-1/2” 8022925 SWG 25-380 3/8”Horizontal 3-1/2” - 4”*1500 1-1/2” 8021957 SWG 20 3/8”Horizontal 2-1/2” - 3”**1050 1-1/2” 8073925 SWG 20-SS 3/8”Horizontal 2-1/2”850 1-1/2” 8269957 SH-GST/CST 20 3/8”45° Angle off Vertical 2-1/2”850 1-1/2” 8269957 SH-GST/CST 20 3/8”45° Angle off Vertical 4”1500 1-1/2” 8139957 SH-GST 20 3/8”17° Angle off Vertical 3”1050 1-1/2”4”1475 1-1/2” SAMMYS FOR STEEL - PIPE HANGER Min Steel Thick Max Steel Thick 8038957 DSTR 1 3/8”Vertical 4”1500 .035”4”1475 .105” 8037957 DSTR 1-1/2 3/8” Vertical 4”1500 .035”4”1475 .105” 8039957 DSTR 516 3/8”Vertical 4”1500 .037”4”1475 .105” 8045957 DST 516 3/8”Vertical 4”1500 .188”4”1475 .188” 8046957 TEK 50 3/8”Vertical 4”1500 .250”4”1475 .188” 8055957 SWDR 1 3/8”Horizontal 4”1500 .037”4”1475 .060” 8056957 SWDR 516 3/8”Horizontal 4”1500 .037”4”1475 .060” 8054957 SWDR 1-1/2 3/8”Horizontal 4”1500 .037”4”1475 .060” 8137957 SH-DSTR 1 3/8”17° Angle off Vertical 4”1500 .035”4”1475 .105” 8268957 SH-TEK 50 3/8”Vertical 2-1/2”850 70° Angle off Vertical 4”1500 8150922 XP 20 3/8”Vertical 2-1/2”850 .027”2”940 .029” 4”1475 .105” 8153922 XP 35 3/8”Vertical 4”1500 .060”2”940 .029” 4”1475 .125” 8294922 SXP 20 3/8”Vertical or up to 45°2”750 .027”2”635 .029” 8295922 SXP 35 3/8”Vertical or up to 89°3-1/2”1250 .060”2”635 .029” 8293957 SWXP 35 3/8”Horizontal 3-1/2”1250 .060” SAMMYS FOR CONCRETE - PIPE HANGER 8059957 CST 20 3/8”Vertical 4”1475 3000 8061957 SWC 20 3/8”Horizontal 4”1475 3000 8150922 XP 20 3/8”Vertical 2-1/2”850 Pre-Pour Structural @ 3000psi 8150922 XP 20 3/8”Vertical 2-1/2”850 Post-Pour Range II LWC ≤ 35 PCF (lbs/ft3) 14 Part Number Model Rod Size Mount Direction UL Load Rating (lbs)UL Min Steel Thickness SAMMYS FOR STEEL - LUMINAIRE FITTING 8150922 XP 20 3/8”Vertical 185 .027” 250 .035” 8153922 XP 35 3/8”Vertical 185 .027” 250 .035” 8181922 XP 200 1/4”Vertical 185 .027” 250 .035” 8294922 SXP 20 3/8”Vertical 170 .027” 45°80 .027” 8295922 SXP 35 3/8”Vertical 250 .060” 90°80 .060” 8293957 SWXP 35 3/8”Horizontal 80 .060” Sheet Steel Gauges Gauge No.22 ga.20 ga.18 ga.16 ga.14 ga.12 ga.1/8”3/16”1/4” Nominal Decimal Equivalent .030”.036”.048”.060”.075”.105”.125”.188”.250” Part Number Model Rod Size Mount Direction UL Load Rating (lbs)UL Min. SteelThickness Listed Application SAMMYS FOR STEEL - CONDUIT, TUBING, AND CABLE 8150922 XP 20 3/8”Vertical 283 .027”Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8”Vertical 500 .060”Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3/8”Vertical 283 .027”Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8”Vertical 500 .060”Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8293957 SWXP 35 3/8”Horizontal 500 .060”Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8149957 CZ2000 1/4” or 3/8”Onto Vertical Rod UL Listed 4S16 - Cable Hanger, Cat. No. C-Z2000 Plenum Rated, Complies w/ NEC Standards *SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2” *SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4” **SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2” **SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3” UL compliance with NEC Standards. UL and FM tests were performed in compliance with NFPA 13 Standards. Fastening requirement: 5 times weight of water-filled schedule 40 pipe plus 250 pounds. APPROVALS For the most up to date information, visit www.itwbuildex.com 15 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETEPart NumberModelRod SizeMount DirectionUL Max Pipe SizeUL Test Load (lbs)UL Min Wood ThicknessFM Max Pipe SizeFM Test Load (lbs)FM Min Wood Thickness SAMMYS FOR WOOD - PIPE HANGER 8007957GST 103/8”VerticalCPVC 1-1/2”3001-1/2” 8020957SWG 103/8”HorizontalCPVC 1-1/2”3001-1/2” 8008957GST 203/8”Vertical2-1/2”8501-1/2”4”14751-1/2” 8068925GST 20-SS3/8”Vertical2-1/2”8501-1/2” 8010957GST 303/8”Vertical4”15001-1/2”4”14751-1/2” 8009925GST 25-3803/8”Vertical4”15001-1/2” 8022925SWG 25-3803/8”Horizontal3-1/2” - 4”*15001-1/2” 8021957SWG 203/8”Horizontal2-1/2” - 3”**10501-1/2” 8073925SWG 20-SS3/8”Horizontal2-1/2”8501-1/2” 8269957SH-GST/CST 203/8”45° Angle off Vertical2-1/2”8501-1/2” 8269957SH-GST/CST 203/8”45° Angle off Vertical4”15001-1/2” 8139957SH-GST 203/8”17° Angle off Vertical3”10501-1/2”4”14751-1/2” SAMMYS FOR STEEL - PIPE HANGERMin Steel ThickMax Steel Thick 8038957DSTR 13/8”Vertical4”1500.035”4”1475.105” 8037957DSTR 1-1/23/8” Vertical4”1500.035”4”1475.105” 8039957DSTR 5163/8”Vertical4”1500.037”4”1475.105” 8045957DST 5163/8”Vertical4”1500.188”4”1475.188” 8046957TEK 503/8”Vertical4”1500.250”4”1475.188” 8055957SWDR 1 3/8”Horizontal4”1500.037”4”1475.060” 8056957SWDR 5163/8”Horizontal4”1500.037”4”1475.060” 8054957SWDR 1-1/23/8”Horizontal4”1500.037”4”1475.060” 8137957SH-DSTR 13/8”17° Angle off Vertical4”1500.035”4”1475.105” 8268957SH-TEK 503/8”Vertical2-1/2”850 70° Angle off Vertical4”1500 8150922XP 203/8”Vertical2-1/2”850.027”2”940.029” 4”1475.105” 8153922XP 353/8”Vertical4”1500.060”2”940.029” 4”1475.125” 8294922SXP 203/8”Vertical or up to 45°2”750.027”2”635.029” 8295922SXP 353/8”Vertical or up to 89°3-1/2”1250.060”2”635.029” 8293957SWXP 353/8”Horizontal3-1/2”1250.060” SAMMYS FOR CONCRETE - PIPE HANGER 8059957CST 203/8”Vertical4”14753000 8061957SWC 203/8”Horizontal4”14753000 8150922XP 203/8”Vertical2-1/2”850Pre-Pour Structural @ 3000psi 8150922XP 203/8”Vertical2-1/2”850Post-Pour Range II LWC ≤ 35 PCF (lbs/ft3) SPECIAL NOTES Engineering Note In 1996, the anchors listed by UL were tested in plate steel that measured .188” and .118”. Subsequent testing was done for z-purlin applications in May 1997 using (.037”) or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Press® was completed using (.030”) or 22 gauge steel metal deck. Sammys® Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric ProductsMetric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for SeismicPlease visit www.itwbuildex.com for our current Seismic product offerring. Vibratory Environments For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8” smaller than root diameter of fastener. Consult the table below: To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPA/NEC StandardsAll UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings / FM ApprovalsUL and FM reports are available at www.itwbuildex.com Technical DrawingsTechnical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Manufactured in the U.S.A. Products Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 Model Root Diameter Hole Size GST 20 .182”1/8” GST 25-380 .280”7/32” SWG 20 .182”1/8” SWG 25-380 .280”7/32” MANUFACTURED U.S.A. Schedule 10 and Schedule 40 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Bull Moose Tube’s Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot-dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. All Schedule 10 and Schedule 40 pipe has a pressure rating of 300 PSI. Schedule 10 Pipe Nominal Pipe Size (in) Nominal O.D. (in) Nominal I.D. (in) Weight/Ft Bundle Size 1 1.315 1.097 1.41 lbs/ft 91 1 1/4 1.660 1.442 1.81 lbs/ft 61 1 1/2 1.900 1.682 2.09 lbs/ft 61 2 2.375 2.157 2.64 lbs/ft 37 2 1/2 2.875 2.635 3.53 lbs/ft 30 3 3.500 3.260 4.34 lbs/ft 19 4 4.500 4.260 5.62 lbs/ft 19 Schedule 40 Pipe Nominal Pipe Size (in) Nominal O.D. (in) Nominal I.D. (in) Weight/Ft Bundle Size 1 1.315 1.049 1.68 lbs/ft 70 1 1/4 1.660 1.380 2.27 lbs/ft 51 1 1/2 1.900 1.610 2.72 lbs/ft 44 2 2.375 2.067 3.66 lbs/ft 30 2 1/2 2.875 2.468 5.80 lbs/ft 30 3 3.500 3.068 7.58 lbs/ft 19 4 4.500 4.026 10.80 lbs/ft 19 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer’s instructions for the specific fitting used. A company 1819 Clarkson Road Chesterfield, MO 63017 (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com e-mail: sales@bullmoosetube.com For additional information, contact your salesperson today at (800) 325-4467 or (636) 537-2600 in the USA, or from Canada call (800) 882-4666 All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 12/09 Ductile Iron Threaded Fittings Ductile Iron Threaded Fittings Ductile Iron Threaded Fittings TemperatureDegrees F Working Pressure, Non-Shock psigClass 300 Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 Specifications • branded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 psi WSP • Ductile iron castings conform to ASTM A536 • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 • All fittings are 100% air tested • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical & mechanical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 • ProPak™ Packaging SCI ProPak™ System SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com237 DUCTILE A A A A A A AA B Size in Part Number A in Packing Weight lbInnerMaster 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 1 35E 3010 1.50 40 80 0.5 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Size in Part Number A in B in Packing Weight lbInnerMaster 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 1-1/2 35F 3014 1.44 20 40 1.0 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35T 3004 1.13 80 160 0.3 3/4 35T 3006 1.31 30 60 0.5 1 35T 3010 1.50 25 50 0.7 1-1/4 35T 3012 1.75 10 20 1.1 1-1/2 35T 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 Fig. 35E 3 – 90° Elbow Fig. 35RE3 – 90° Reducing Elbow Fig. 35F 3 – 45° Elbow Fig. 35T 3 – Tee Ductile Iron Threaded Fittings - Class 300 UL/FM SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 238 DUCTILE A B AB C C Size in Part Number A in B in C in Packing Weight lbInnerMaster 3/4 x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 1 x 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 1 x 1/2 x 1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1 x 3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 1 x 3/4 x 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 1 x 3/4 x 1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4 x 3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2 x 3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2 x 3/4 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2 x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2 x 1 x 1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2 x 1 x 3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2 x 1 x 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1/2 x 1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2 x 1-1/4 x 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2 x 1-1/4 x 1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2 x 1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2 x 1-1/2 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2 x 1-1/2 x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 Size in Part Number A in B in C in Packing Weight lbInnerMaster 3/4 x 1 35BT3006010 1.45 1.45 1.37 30 60 0.6 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 1 x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 1-1/4 x 1 x 1-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1.2 1-1/4 x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2 x 2 35BT3014020 2.16 2.16 2.02 8 16 1.8 Fig. 35BT3 – Bull Head Tee Fig. 35RT3 – Reducing Tee Ductile Iron Threaded Fittings - Class 300 UL/FM SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com239 DUCTILE A A A AA B Size in Part Number A in Packing Weight lbInnerMaster 1 35U 3010 2.19 20 40 1.0 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 3.12 6 12 2.4 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Size in Part Number A in Packing Weight lbInnerMaster 1 x 1/2 35RC3010004 1.69 80 160 0.3 1 x 3/4 35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (not hex)35RC3020010 2.81 20 40 1.0 Size in Part Number A in B in Packing Weight lbInnerMaster 1 x 1/2 35HB3010004 1.06 1.40 180 360 0.2 1 x 3/4 35HB3010006 1.06 1.40 180 360 0.1 1-1/4 x 1 35HB3012010 1.19 1.80 90 180 0.2 1-1/2 x 1 35HB3014010 1.25 1.95 75 150 0.4 1-1/2 x 1-1/4 35HB3014012 1.25 1.95 75 150 0.3 2 x 1 35HB3020010 1.38 2.55 40 80 0.6 2 x 1-1/4 35HB3020012 1.38 2.55 40 80 0.6 2 x 1-1/2 35HB3020014 1.38 2.55 40 80 0.6 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35CP3 – Straight Coupling with Ribs Fig. 35RC3 – Hex Reducing Coupling Fig. 35HB3 – Hex Bushing Fig. 35SP3 – Square Head Plug Fig. 35U 3 – Union with Brass Seat Ductile Iron Threaded Fittings - Class 300 UL/FM SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 240 DUCTILE A A A A A A A B B Size in Part Number A in B in Packing Weight lbInnerMaster 1-1/4 x 1 35RX3012010 1.67 1.58 15 30 1.2 1-1/2 x 1 35RX3014010 1.80 1.65 12 24 1.4 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 Size in Part Number A in Packing Weight lbInnerMaster 1 35X 3010 1.50 20 40 0.9 1-1/4 35X 3012 1.75 12 24 1.4 1-1/2 35X 3014 1.94 8 16 1.8 2 35X 3020 2.25 6 12 2.8 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35C 3004 0.87 300 600 0.1 3/4 35C 3006 0.97 200 400 0.1 1 35C 3010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35X 3 – Cross Fig. 35RX3 – Reducing Cross Fig. 35C 3 – Cap Size in Part Number A in Packing Weight lbInnerMaster 3/8 35BC3003 0.75 100 200 0.3 1/2 35BC3004 0.75 80 160 0.5 Fig. 35BC3 – Beam Clamp A Ductile Iron Threaded Fittings - Class 300 UL/FM MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.06.26 Rev 20.3 Page 1 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTIONViking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired.The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile cover assembly that provides up to ½” (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “The “push-on” and “thread-on” designs of the concealed cover plate assemblies allow easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive environments and is listed and approved as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 VdS Approved: Certificate G4080021 LPCB Approved: Ref. No. 096e/12 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032 China Approval: Approved according to China GB Standard Refer to the Approval Charts and Design Criteria listing and approval requirements that must be followed. 3. TECHNICAL DATA Specifications:Available since 2006.Minimum Operating Pressure: 7 psi (0.5 bar)*Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating “250” stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar)Thread size: 1/2” (15 mm) NPTNominal K-Factor: 5.6 U.S. (80.6 metric**)Glass-bulb fluid temperature rated to -65°F (-55°C)Patents Pending * cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). ** Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards:Sprinkler Body: Brass UNS-C84400Deflector: Copper UNS-C19500 for Sprinkler; Phosphor Bronze UNS-C51000 for Sprinkler VK463Deflector Pins: Stainless Steel AlloyBulb: Glass, nominal 3 mm diameterPip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400Button: Brass UNS-C36000 Screws: 18-8 Stainless SteelBelleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE TapeYoke: Phosphor Bronze UNS-C51000Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials:Cover: Copper UNS-C11000 or Stainless Steel UNS-S30400Base: Brass UNS-C26000 or UNS-C26800Springs: Nickel AlloySolder: Eutectic Ordering Information: The sprinkler and cover plate must be ordered separately. Refer to Tables 1 and 2. Replaces Form No. F_103005 Rev 20.2 (Added cover plate options.) MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.06.26 Rev 20.3 Page 2 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 4. INSTALLATIONRefer to appropriate NFPA Installation Standards. 5. OPERATIONDuring fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCERefer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITYViking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEEFor details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: SPRINKLER ORDERING INFORMATION Instructions: (1) Select a Sprinkler Base Part Number (2) Add the suffix for the desired Finish (3) Add the suffix for the desired Sprinkler Temperature Rating (4) Order a cover plate (refer to Table 2) Example: 13503AE = 200 °F (93 °C) Temperature Rated Sprinkler with a standard Brass finish. SIN Sprinkler Base Part Number8 Size 1: Finishes 2: Temperature Ratings NPT Inch BSPT mm Description Suffix1 Sprinkler Temperature Classification Nominal Rating Bulb Color Max. Ambient Ceiling Temperature2 Suffix VK462 13503 1/2 --Brass A Ordinary 155 °F (68 °C)Red 100 °F (38 °C)B VK462 213567,9 --15 ENT 3,4 JN Intermediate 175 °F (79 °C)Yellow 150 °F (65 °C)D VK463 13667 1/2 --Intermediate 200 °F (93 °C)Green 150 °F (65 °C)E Accessories Sprinkler Wrenches and tools (see Figure 1): A. Heavy Duty Part Number: 14047W/B5 (available since 2006) B. Head Cabinet Wrench Part Number: 140316 (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part Number: 1441210 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 1486710 (available since 2007) Sprinkler Cabinet:Holds up to 6 sprinklers: Part number 01731A (available since 1971). Footnotes 1. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. 2. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. UL Listed as corrosion resistant. 4. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. 5. Requires a ½” ratchet (not available from Viking). 6. Also optional for removal of the protective cap. Ideal for sprinkler cabinets. 7. Not available with ENT finish. See approval charts for more information. 8. See approval charts for more information. 9. Approved according to China GB Standard. 10. The installer tool is for push-on style cover plates only. MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.06.26 Rev 20.3 Page 3 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com TABLE 2: COVER PLATE ORDERING INFORMATION Instructions: (1) Select a Cover Plate Base Part Number (2) Add the suffix for the desired Finish (3) Add the suffix for the required Cover Plate Nominal Rating. Example: 23190MC/W = 165 °F (74 °C) Temperature Rated, 2-3/4” (70 mm) diameter, Thread-On style Round Cover Plate with a Painted White finish. 1: Select a Cover Plate Base Part Number3 2: Select a FinishThread-On Style Push-On Style Base Part Number Size Inch (mm)Type Base Part Number Size Inch (mm)Type Description Suffix5 23190 2-3/4 (70)Round 23447 2-3/4 (70)Round Polished Chrome F 23174 3-5/16 (84)Round 23463 3-5/16 (84)Round Brushed Chrome F-/B 23179 3-5/16 (84)Square 23482 3-5/16 (84)Square Bright Brass B 231934 2-3/4 (70)Stainless Steel Round 234554 2-3/4 (70)Stainless Steel Round Antique Brass B-/A Brushed Brass B-/B 231834 3-5/16 (84)Stainless Steel Round 234734 3-5/16 (84)Stainless Steel Round Brushed Copper E-/B Painted White M-/W 23174-/CR 3-5/16 (84)Clean Room 23463-/CR 3-5/16 (84)Clean Room Painted Ivory M-/I 23183CR4 3-5/16 (84) Stainless Steel Round Clean Room 23473CR4 3-5/16 (84) Stainless Steel Round Clean Room Painted Black M-/B 3: Temperature Rating Matrix1,2 Cover Plate Nominal Rating (Required) Temperature Classification Sprinkler Nominal Rating Sprinkler Maximum Ambient Ceiling Temperature2 Suffix UL: 135 °F (57 °C) FM: 139° F (59 °C)Ordinary 155 °F (68 °C)100 °F (38 °C)A 165 °F (74 °C)Intermediate 175 °F (79 °C)150 °F (65 °C)C 165 °F (74 °C)Intermediate 200 °F (93 °C)150 °F (65 °C)C Footnotes 1. The sprinkler temperature rating is stamped on the deflector. 2. Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 4. Stainless Steel versions are not available with any finishes or paint. 5. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.06.26 Rev 20.3 Page 4 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart 1 (UL) Mirage® Concealed Pendent Sprinklers VK462 and VK463 Sprinkler Base Part No.1 SIN Thread Size Nominal K-factor Maximum Water Working Pressure Listings and Approvals4 (Refer also to Design Criteria) NPT Inch BSPT mm U.S.metric2 cULus5 NYC VdS7 LPCB China Approval Standard Response Applications 13503A VK462 1/2”--5.6 80.6 175 psi (12 bar)----AY1, CZ1 AY1, BZ1 AY1, CZ18 -- 21356A12 VK462 --15 5.6 80.6 175 psi (12 bar)----------AY1, CZ1 Quick Response Applications 13503A VK462 1/2”15 5.6 80.6 175 psi (12 bar)AV1, BX1, AS2, BT2 AV1, BX16 -------- 13503JN11 VK462 1/2”15 5.6 80.6 175 psi (12 bar)AV1, BX1, AS2, BT2 AV1, BX16 -------- 21356A12 VK462 --15 5.6 80.6 175 psi (12 bar)AY1, CZ1 ---------- 13667A VK463 1/2”15 5.6 80.6 250 psi (17.2 bar)3 AV1, BX1 AV1, BX16 -------- 13667JN11 VK463 1/2”15 5.6 80.6 250 psi (17.2 bar)3 AV1, BX1 AV1, BX16 -------- Approved Sprinkler Temperature Rating Codes Approved Cover Plate Temperature Rating Codes Approved Cover Plate Finish Codes A = 155 °F (68 °C) B = 175 °F (79 °C) C = 200 °F (93 °C) S - 135 °F (57 °C) cover 23193, 23445 or 23183, 23473 (large diameter) T - 165 °F (74 °C) cover 23193, 23445 or 23183, 23473 (large diameter) V - 135 °F (57 °C) cover 23190, 23447, 23174, 23463 (large diameter), or 23179, 23482 (square cover plate) X - 165 °F (74 °C) cover 23190, 23447, or 23174, 23463 (large diameter) Y - 135 °F (57 °C) cover 23190, 23447 LPCB Approved as 139 °F (59 °C) Z - 165 °F (74 °C) cover 23190, 23447 1 - Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 2 - Stainless Steel Footnotes 1. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. The Water Working Pressure rating is stamped on the deflector. 4. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5. Listed by Underwriter’s Laboratories for use in the U.S. and Canada. 6. Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. 7. VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999 + A1:2001 + A2:2004 + A3:2006, Certificate G4080021. 8. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. 9. The 135/139 °F cover has an orange label. The 165 °F (74 °C) cover has a white label. 10. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. 11. cULus Listed as corrosion resistant. 12. Approved according to China GB Standard. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.06.26 Rev 20.3 Page 5 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA - UL (Also refer to Approval Chart 1) cULus Listing Requirements: Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. • For hazard occupancies up to and including Ordinary Hazard, Group II. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). • Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. • Minimum distance from walls is 4 in. (102 mm). • Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. • The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS Approval Requirements: a) The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. b) This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. c) Follow installation guidelines of current standards, CEA4001VdS and EN12845. These sprinklers can only be installed in LH and OH occupan- cies, except in OH4. NOTES: Due to the design the sprinkler type ‘Domed-CCP’ shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type ‘Domed-CCP’ shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: 1. Prepare the sprinkler key. 2. Remove the plastic cover. 3. Hold the sprinkler with the wrench and fasten it. 4. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Figure 1: Identification of Custom Paint for Concealed Covers Figure 2: Square Cover Assembly All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label.FACTORY APPLIE D C USTO M P A I NT COLOR MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.06.26 Rev 20.3 Page 6 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Approval Chart 2 (FM) Mirage® Standard Response Concealed Pendent Sprinkler VK462 Sprinkler Base Part No.1 SIN Thread Size Nominal K-Factor Maximum Water Working Pressure FM Approvals3 (Refer also to Design Criteria below.)NPT Inch BSPT mm U.S.metric2 13503A VK462 1/2”15 5.6 80.6 175 psi (12 bar)AW1, BX1, AY2, BZ2 21356A6 VK462 --15 5.6 80.6 175 psi (12 bar)AU1, CV1 Approved Sprinkler Temperature Rating Codes Approved Cover Plate Temperature Rating Codes Approved Cover Plate Finish Codes A - 155 °F (68 °C) B - 175 °F (79 °C) and 200 °F (93 °C) C - 200 °F (93 °C) U - 139 °F (59 °C) cover 23190, 23447 V - 165 °F (74 °C) cover 23190, 23447 W - 139 °F (59 °C) cover 23190, 23447, or 23174, 23463 (large diameter), or 23179, 23482 (square cover plate) X - 165 °F (74 °C) cover 23190, 23447, 23174, 23463 (large diameter), or 23179, 23482 (square cover plate) Y - 139 °F (59 °C) cover, 23183, 23473 or 23193, 23455 Z - 165 °F (74 °C) cover 23183, 23473 or 23193, 23455 1 - Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 2 - Stainless Steel Footnotes 1. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4. The 139 °F (59 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. 5. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. 6. Approved according to China GB Standard. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Form No. F_103005 20.06.26 Rev 20.3 Page 7 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins Sprinkler Wrench Part No. 14047W/B** ** A 1/2” ratchet is required (Not available from Viking) 2-1/4” (57 mm) diameter opening required in the ceiling. Step 2: Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Figure 3: Sprinkler Installation and Proper Wrench Usage NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Sprinkler wrench flat Sprinkler frame arms Figure 4: Sprinkler Dimensions and Cover Installation 1/2” (15 mm) NPT 2-3/16”(55 mm)2-9/16” (65 mm)Maximum 2-1/16” (52 mm)Minimum 2-3/4” (70 mm) or 3-5/16” (84 mm)NOTE: Upon sprinkler activation, the deflector descends to approximately 13/16” (21 mm) below the sprinkler body. Replaces Form No. F_103005 Rev 20.2 (Added cover plate options.) Job Name:Contractor: Location:Quantity: Engineer:Date: TEL: 714-919-7814 FAX: 714-464-5474 Features * Reduce Pipe Vibration and Noise * Prevent Electrolysis * Galvanized Finished * 360 Degree Rotation * UL Listed * FM Approved * Comply with Federal Specification WW-H-171E and American Manufactures Standardization Society 69 & SP58 Specification Rod Size: 3/8" or 1/2" Nominal Pipe Size: 1/2" to 8" Material: Carbon Steel Support: Copper, Steel or CPVC Pipes Pipe Size OD (in)RS A (in)B (in)C (in)Max. Load (lb) 1/2"0.840 3/8"2.68 1.18 0.79 300 3/4"1.050 3/8"3.00 1.81 0.94 300 1"1.315 3/8"3.15 1.57 1.18 300 1-1/4"1.660 3/8"3.66 1.97 1.38 300 1-1/2"1.900 3/8"3.94 2.17 1.38 300 2"2.375 3/8"4.33 2.36 1.30 300 2-1/2"2.875 3/8"5.71 3.62 2.56 1,000 3"3.500 3/8"6.10 3.94 2.76 1,000 4"4.500 3/8"7.36 4.72 3.15 1,100 6"6.625 1/2"9.96 6.30 3.94 1,250 8"8.625 1/2"12.88 6.88 2.88 1,250 www.akwsupply.com Felt Hangers AKW Supply Co.product specifications and dimensions are approximate and are provided for reference only.It's the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of our products.AKW Supply Co.reserves the right to change or modify product design,construction,specification,model number or material without prior notice and without incurring any obligation to make such changes on AKW Supply Co. previously sold. SUBMITTAL SHEET Job Name:Contractor: Location:Quantity: Engineer:Date: TEL: 714-919-7814 FAX: 714-464-5474 Features * Concave Bend * Electro-Galvanized Finished * 360 Degree Rotation * UL Listed * FM Approved * Comply with Federal Specification WW-H-171E and American Manufactures Standardization Society 69 & SP58 Specification Rod Size: 3/8" or 1/2" Pipe Size: 1/2" to 8" Material: Carbon Steel Support: Steel or CPVC Pipes Pipe Size OD (in)RS A (in)B (in)C (in)Max. Load (lb) 1/2"0.840 3/8"2.68 1.18 0.79 300 3/4"1.050 3/8"3.00 1.81 0.94 300 1"1.315 3/8"3.15 1.57 1.18 300 1-1/4"1.660 3/8"3.66 1.97 1.38 300 1-1/2"1.900 3/8"3.94 2.17 1.38 300 2"2.375 3/8"4.33 2.36 1.30 300 2-1/2"2.875 3/8"5.71 3.62 2.56 1,000 3"3.500 3/8"6.10 3.94 2.76 1,000 4"4.500 3/8"7.36 4.72 3.15 1,100 6"6.625 1/2"9.96 6.30 3.94 1,250 8"8.625 1/2"12.88 6.88 2.88 1,250 www.akwsupply.com Loop Hangers AKW Supply Co.product specifications and dimensions are approximate and are provided for reference only.It's the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of our products.AKW Supply Co.reserves the right to change or modify product design,construction,specification,model number or material without prior notice and without incurring any obligation to make such changes on AKW Supply Co. previously sold. SUBMITTAL SHEET Job Name:Contractor: Location:Quantity: Engineer:Date: TEL: 714-919-7814 FAX: 714-464-5474 Features * Galvanized Finished * UL Listed * Comply with Federal Specification WW-H-171E and American Manufactures Standardization Society 69 & SP58 Specification Rod Size: 3/8" or 1/2" Pipe Size: 1/2" to 8" Material: Carbon Steel Support: Rigid Steel Pipes Pipe Size Bolt A (in)B (in)Max. Load (lb) 1/2"3/8"8-1/2"1"220 3/4"3/8"9"1"220 1"3/8"9"1"220 1-1/4"3/8"9-1/2"1"250 1-1/2"3/8"9-7/8"1"250 2"1/2"10-2/7"1-1/6"300 2-1/2"1/2"11"1-1/6"400 3"1/2"11-3/4"1-1/6"500 4"1/2"13"1-1/2"750 6"1/2"15-1/2"2"1,600 8"1/2"18-1/4"2"2,500 www.akwsupply.com Riser Clamps AKW Supply Co.product specifications and dimensions are approximate and are provided for reference only.It's the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of our products.AKW Supply Co.reserves the right to change or modify product design,construction,specification,model number or material without prior notice and without incurring any obligation to make such changes on AKW Supply Co. previously sold. SUBMITTAL SHEET Job Name:Contractor: Location:Quantity: Engineer:Date: TEL: 714-919-7814 FAX: 714-464-5474 Features * Hanger Component for Steel Pipe * Electro-Galvanized Finished * UL Listed * Comply with Federal Specification WW-H-171E and American Manufactures Standardization Society 69 & SP58 Specification Rod Size: 3/8" or 1/2" Pipe Size: 1/2" to 8" Material: Carbon Steel Support: Rigid Steel Pipes Pipe Size Bolt A (in)B (in)Max. Load (lb) 1/2"3/8"3"3/7"500 3/4"3/8"3-1/5"1/2"500 1"3/8"3-3/4"1/2"500 1-1/4"3/8"3-8/9"1/2"500 1-1/2"3/8"4-1/4"1/2"800 2"1/2"5-3/7"2/3"1040 2-1/2"1/2"6-1/2"5/8"1,040 3"1/2"7-2/7"5/7"1,040 4"1/2"9"3/4"1,040 6"1/2"11-2/3"1/2"1,615 8"1/2"14-1/7"1"1,615 www.akwsupply.com Short Clamps AKW Supply Co.product specifications and dimensions are approximate and are provided for reference only.It's the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of our products.AKW Supply Co.reserves the right to change or modify product design,construction,specification,model number or material without prior notice and without incurring any obligation to make such changes on AKW Supply Co. previously sold. SUBMITTAL SHEET Job Name:Contractor: Location:Quantity: Engineer:Date: TEL: 714-919-7814 FAX: 714-464-5474 Features * Continuously Threaded * Electro-Galvanized Finished * Sold in Bundles Specification * Low Carbon Steel * Material Conforms to ASTM A307 * Thread: Coarse Thread UNC * Finish Conforms to ASTM B 633 * Length: 10 Feet Size PCS/Bundle Lb/Ft Lbs/Bundle 3/8" - 16 X 10Ft 25 0.30 75.0 1/2" - 13 X 10Ft 12 0.50 60.0 5/8" - 11 X 10Ft 8 0.84 67.2 3/4" - 10 X 10Ft 5 1.20 60.0 AKW Supply Co.product specifications and dimensions are approximate and are provided for reference only.It's the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of our products.AKW Supply Co.reserves the right to change or modify product design,construction,specification,model number or material without prior notice and without incurring any obligation to make such changes on AKW Supply Co. previously sold. All Threaded Rods www.akwsupply.com SUBMITTAL SHEET Job Name:Contractor: Location:Quantity: Engineer:Date: TEL: 714-919-7814 FAX: 714-464-5474 Features * Brand: BIS * UL Listed * FM Approved * 100% Air Tested Each Fitting * Strong Tensile Strength * Black Color * Style: Banded Specification Material: Ductile Iron Casting: Conform to ASTM A536 Class 65-45-12 Max. Cold Working Pressure: 300 PSI (Based on Sch 40 Pipes) Fittings Dimension: Conform to ASME B16.3 Thread Standard: NPT Conform to ASME B1.20.1 Tensile Strength: 448 Mpa Elongation: 12% Ductile Iron Fittings www.akwsupply.com AKW Supply Co.product specifications and dimensions are approximate and are provided for reference only.It's the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of our products.AKW Supply Co.reserves the right to change or modify product design,construction,specification,model number or material without prior notice and without incurring any obligation to make such changes on AKW Supply Co. previously sold. Notice:Due to high tensile strength of DI Fittings,over tightening can cause pipe threads damages and may cause leakage.DI Fittings should not be tightened more than one turn beyond hand tighten. Always check for leaks. SUBMITTAL SHEET Specification Name:Fire Sprinkler CSI Code:21 13 13 -003 Detail Description:211313-003.0 Fire Sprinkler (H1), Drawings & Hydr Status:For Approval Category:Product Data/Specifications Submittal Pkg. #:087 Date:10/25/2021 Due Date:11/1/2021 REVIEWED AND FORWARDED FOR APPROVAL REVIEWED WITH EXCEPTIONS NOTED NONCONFORMING, REVISED & RESUBMITTED The Submittals have been reviewed for general conformation to the design intent of the contract documents with regard to type and quality and not quantity and/or dimensions, which are the responsibility of the subcontractor and/or supplier making the submittal. The subcontractor and/or supplier is responsible for coordination of their work with other trades. Review of submittals and/or shop drawings does not relieve the subcontractor's and/or supplier's responsibility for any errors, omissions and/or changes for the requirements of the contract documents, nor for errors and/or omissions made by subcontractor and/or supplier in bad submittals and/or shop drawings. R.D. OLSON CONSTRUCTION BY:Sam Sheinberg DATE:10/25/2021 JOB:Montage Hotel and Spa (210425)SPEC:21 13 13 -003 Project Name:Montage Hotel and Spa Project Number: 210425 Comment: 211313-002.0 Fire Sprinkler (H1), Drawings & Hydraulic Reports - Pool Bar - Lobby - Kitchen - Porte Cochere - Golf Cart Path - Pool Equipment Room Please note that the Hotel portion of this package is expected to be submitted in 3-4 weeks. This is a deferred submittal. Once we have the Hotel & Spa shop drawings and flow tests submitted and approved, we will combine the submittal (211313-001.0 Fire Sprinkler Material, Product Data) for one submittal to the City of La Quinta Building Department and/or Fire Department. Please review sprinkler head locations. RDOC will submit a separate document for sprinkler head colors by location to review with ID. Submittal Transmittal 400 SPECTRUM CENTER DRIVE, SUITE 1200 IRVINE, CALIFORNIA 92618 TEL: 949-474-2001 WEBSITE: WWW.RDOLSON.COM Page 1 of 1 SUBMITTAL REVIEW NO EXCEPTIONS TAKEN. MAKE CORRECTIONS AS NOTED. Resubmittal not required unless Contractor cannot comply with corrections noted. REVISE AS NOTED AND RESUBMIT. RESUBMIT PROPERLY. Submittal not reviewed for reasons noted. NOT REVIEWED. Submittal not required by Contract Documents. RECEIVED FOR CLIENT’S RECORD ONLY. Submittal not reviewed. Gensler has reviewed this Submittal, but only for the purpose of checking for conformance with the design intent expressed in the Contract Documents. Gensler’s action on a specific item does not indicate approval of an assembly of which the item is a component, nor of an item as delivered and installed if it does not conform to the Contract Documents. Contractor is responsible for checking for deviations between this Submittal and differing information or conditions in the Contract Documents and field conditions; for determining or substantiating the accuracy and completeness of other details such as dimensions and quantities; for substantiating instructions for installation or performance of equipment or systems designed by Contractor; for construction means, methods, techniques, schedules, sequences, procedures, and fabrication processes; for errors and omissions in Submittals; for coordination of the Work of the trades, safety precautions and performing the Work in a safe and satisfactory manner and in conformance with the Contract Documents. If more than one submittal review stamp appears on this Submittal, the most stringent action and notations thereon apply. Signature of a submittal review stamp by Gensler or a consultant does not imply that it has reviewed work not within its professional discipline or scope of services. v1 3/2012 By: Date: Project No: Submittal: Tam Tran Fri Nov 12, 2021 55.7598.000 211313-003.0 - Fire Sprinkler (H1) SD //gensler.ad/Projects/55/55.7598.000/Documentation/6 - CA/6S - Sub, SD, SR/Constructio IT IS ACCEPTABLE TO SUBMIT THIS SUBMITTAL FOR PERMIT. HOWEVER, ARCHITECT AND OWNER REQUESTS AND EXPECTS A SEPARATE SUBMITTAL FOR RCP COORDINATION OF SPRINKLER HEADS IN RELATIONSHIP TO OTHER OBJECTS IN THE CEILING. THIS SUBMITTAL HAS COMMENTS REGARDING ALIGNMENTS AND LOCATION AND OTHER REQUESTS WHICH IS TO BE PICKED UP IN A SEPARATE SUBMITTAL. OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org July 6, 2022 J C Fire Protection 81705 De Oro Ave Indio, CA 92201 Re: New Fire Sprinkler System Plan Review – MONTAGE HOTEL – POOL BAR 79195 AHMANSON LANE, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. 1) Approval of these plans does not include the piping of the underground system. Installing contractor shall provide separate underground plans for review and approval prior to installation. 2) All persons performing work on the automatic fire sprinkler system shall be Certified Sprinkler Fi tters or Registered with the State Fire Marshal for Apprentice or Trainee classification. 3) The completed Contractor’s Material and Test Certificate for Aboveground Piping shall be provided to the fire inspector prior to a final inspection. 4) Permanently marked identification signs shall be attached to all control valves. 5) A sign shall be located adjacent to the alarm bell worded as follows: a) SPRINKLER FIRE ALARM - WHEN BELL RINGS CALL 911 6) The fire sprinkler system shall be monitored and supervised by an approved Dedicated Function - Fire Sprinkler Monitoring System. 7) Each system shall have an Air-Relief valve in compliance with NFPA 13 installed in a remote, most elevated location. 8) CA compliant Hydraulic Calculation Placards shall be installed on the riser or other approved location. Risers shall have signage indicating the location of remotely located placards. 9) Single head sprinkler drops located in suspended ceilings shall be provided with seismic escutcheons or other approved devices for restraint or seismic bonding. 10) The following inspections/tests are required to be witnessed by Office of the Fire Marshal staff: a) Overhead Rough: All installed/relocated piping must be visible. b) Overhead Hydro: Entire system shall be hydrostatically tested at a minimum of 200 psi for 2 hours. c) Underground Supply Flush: Flush of the underground supply line until clear of all debris and to the satisfaction of the inspector. d) Final inspection: Water-flow signal test as performed from the inspector test valve. As-Built plans required to be maintained on site as approved by the inspector. General Information sign and Hydraulic Calculation plate(s) provided. Title 19 “New” system tag affixed to riser. NOTE: The underground flush shall be done through a pipe or hose equal in size to the sprinkler underground supply pipe, prior to connection to the above ground sprinkler piping. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 79195 AHMANSON LANE PERMIT#: FSS2021-0260 DATE ISSUED: 7/6/2022 DESCRIPTION: MONTAGE HOTEL – POOL BAR CONTRACTOR: J C FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.