FSS2021-0290ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT J D MECHANICAL FIRE INC 82579 FLEMING WAY SUITE D INDIO CA 92201 (760)775-6220 KATHY@JDMECHANIC AL.CO CONTRACTOR J D MECHANICAL FIRE INC 82579 FLEMING WAY SUITE D INDIO CA 92201 (760)775-6220 KATHY@JDMECHANIC AL.CO OWNER GALA ASHER 81560 BAFFIN AVE LA QUINTA CA 92253 (760)775-6220 CONDITIONS Description: ASHER / FIRE SPRINKLER / CUSTOM HOME Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 12/21/2021 ECON Parcel No: 767710013 Site Address: 81560 BAFFIN AVE LA QUINTA,CA 92253 Approved: 1/12/2022 KHET Subdivision: TR 33076-2 Block: Lot: 100 Issued: 1/12/2022 JOD Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 5/18/2022 KHET Valuation: $10,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Friday, March 03, 2023 1:49:52 PM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0290 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 1/20/2022 1/21/2022 APPROVED OVERHEAD HYRO KHET 1/20/2022 1/21/2022 APPROVED FIRE FINAL**KHET 5/18/2022 5/18/2022 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE - ETRAKIT (2 WK) KOHL HETRICK 12/21/2021 1/10/2022 1/4/2022 REVISIONS REQUIRED SEE ATTACHMENTS PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $333.00 $333.00 1/12/22 WEB10357 634766448 92 CREDIT 1020141 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $250.00 $250.00 1/12/22 WEB10357 634766448 92 CREDIT 1020141 ECON Total Paid for FIRE FEES: $583.00 $583.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 1/12/22 WEB10357 634766448 92 CREDIT 1020141 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 1/12/22 WEB10357 634766448 92 CREDIT 1020141 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$599.00 $599.00 Printed: Friday, March 03, 2023 1:49:52 PM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0290 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 12/21/2021 Etrakit Contractor 1ST SUBMITTAL - CALCS Document.pdfCalc-1.pdf 1 DOC 12/21/2021 Etrakit Contractor 1ST SUBMITTAL - PLAN SET PG FP2 Madison Lot 100 2nd Try.pdf1st Floor Piping.pdf 1 DOC 12/21/2021 Etrakit Contractor 1ST SUBMITTAL - PLAN SET FP4 Madison Lot 100 2nd Try.pdf1st Floor RCP.pdf 1 DOC 12/21/2021 Etrakit Contractor 1ST SUBMITTAL - PLAN SET FP3 Madison Lot 100 2nd Try.pdf2nd Floor Piping.pdf 1 DOC 12/21/2021 Etrakit Contractor 1ST SUBMITTAL - PLAN SET FP5 Madison Lot 100 2nd Try.pdf2nd Floor RCP.pdf 1 DOC 12/21/2021 Etrakit Contractor 1ST SUBMITTAL - PLAN SET FP1 Madison Lot 100 2nd Try.pdfSite.pdf 1 DOC 12/21/2021 Etrakit Contractor 1ST SUBMITTAL - CVWD LETTER Scan_0001.pdf 1 DOC 12/21/2021 Etrakit Contractor 1ST SUBMITTAL - CONCEAL PENDANT Senju Residential Conceled Pendant.pdf 1 DOC 1/5/2022 Etrakit Contractor 1st Floor Piping.pdf corrections x2 lot 100.pdf 1 DOC 1/5/2022 Etrakit Contractor 2nd Floor Piping Plan.pdf corrections x2 lot 100.pdf 1 BOND INFORMATION 1ST PERMIT TECH – ETRAKIT (1 DAY) ARMANDO MAGALLON 12/21/2021 12/22/2021 12/21/2021 PENDING DOCUMENTS NO DOCUMENTS UPLOADED 2ND FIRE (1 WK)KOHL HETRICK 1/5/2022 1/12/2022 1/12/2022 APPROVED SEE ATTACHMENTS Printed: Friday, March 03, 2023 1:49:52 PM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0290 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 1/5/2022 Etrakit Contractor Document.pdfCalc-1.pdf corrections x 2 lot 100.pdf 1 DOC 1/5/2022 Etrakit Contractor Site.pdf corrections x2 lot 100.pdf 1 DOC 1/5/2022 Etrakit Contractor Site.pdf corrections x2 lot 100_1.pdf 1 DOC 1/5/2022 Etrakit Contractor Scan_0001.pdf corrections lot 100.pdf 1 DOC 1/5/2022 Etrakit Contractor 1st Floor Piping.pdf corrections lot 100.pdf 1 DOC 1/5/2022 Etrakit Contractor 2nd Floor piping plan.pdf corrections lot 100.pdf 1 DOC 1/5/2022 Etrakit Contractor Document.pdfCalc-1.pdf corrections lot 100.pdf 1 DOC 1/5/2022 Etrakit Contractor Site.pdf corrections lot 100.pdf 1 DOC 1/21/2022 JOSE DELGADO FSS2021-0290 APPROVED OH ROUGH 1.20.2022.pdf FSS2021-0290 APPROVED OH ROUGH 1.20.2022.pdf 0 DOC 1/4/2022 KOHL HETRICK FSS2021-0290 - 1ST REVIEW - PLAN CORRECTIONS.pdf FSS2021-0290 - 1ST REVIEW - PLAN CORRECTIONS.pdf 1 DOC 1/7/2022 KOHL HETRICK 2ND SUBMITTAL - PLANS AND CALCS.pdf 2ND SUBMITTAL - PLANS AND CALCS.pdf 1 DOC 1/12/2022 KOHL HETRICK FSS2021-0290 - APPROVED PLANS AND CALCS.pdf FSS2021-0290 - APPROVED PLANS AND CALCS.pdf 1 DOC 1/12/2022 KOHL HETRICK FSS2021-0290 - COA AND JOB CARD.pdf FSS2021-0290 - COA AND JOB CARD.pdf 1 Printed: Friday, March 03, 2023 1:49:52 PM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2021-0290 FSS2021-0290 2" PVC UNDERGROUND BY OTHERS NOTIFICATION DEVICE BY OTHERS UP TO 2nd FLOOR UP TO 2nd FLOOR 1" 3' -7" 1" 0' -3" 1" 3' -0"1"3' -0"1"3' -0"1"9' -0"1" 7' -8" 1" 0' -4" 1" 14' -7" 1" 12' -6" 1" 11' -7"1"14' -0"1" 15' -9" 1" 15' -9" 1" 2' -10" 1" 2' -6" 1" 2' -6"1"14' -0"1" 14' -0" 1" 14' -0"1"7' -0"1" 1' -2"1"5' -0"1" 2' -9"1"3' -10"1"5' -6"1" 12' -0" 1" 12' -0" 1" 5' -3"1"5' -2"1" 12' -0"1"5' -2"1" 5' -6"1"5' -6"1" 7' -10"1"5' -6"1"5' -6"1"5' -10"1"5' -10"1"3' -7"1"3' -7"1" 8' -7" 1" 2' -5"1"8' -7"1"8' -0"1" 11' -0"1"6' -0"1"12' -5"1"2' -7"1" 2' -3" 1" 9' -10" 1" 1' -5" 1" 2' -9"1"7' -2"1"3' -3"1" 6' -8" 1" 14' -0" 1" 14' -0" 1" 14' -0"1"6' -8"1" x 3' -0"1"16' -0"1"16' -0"1"15' -0"1"15' -0"1"15' -0"1" 1' -5" 1" 1' -5" 1" 1' -5" 1" 1' -5" 1" 14' -7" 1" 14' -7" 1" 14' -7" 1" 15' -8"1"7' -3"1" 6' -2"1" 6' -4" 1" 6' -4" 1" 6' -4" 1" 0' -4"1"15' -0"1" 0' -4"1"15' -0"1"15' -0"1" 0' -4"1"15' -0"1" 9' -5" 1" 8' -8"1"2' -7"1" 6' -9"1"8' -4"1" 5' -3" 1" 6' -2"1" x 3' -0"1" 7' -8" 1" 7' -8" 1" 6' -10" 1" 2' -0"1"9' -0"1" 1' -0"1"3' -8"1" 5' -4" 1" 1' -6"1"8' -8"1"10' -5"1" 3' -9"1"3' -0"1"5' -2"1" 3' -9"1"0' -8"1" 1' -4" 1" 6' -6"1"7' -8"1" 2' -11" 1" 6' -10"1" x 3' -0"1" 5' -1" 1" 2' -5"1"5' -9"1" 3' -3" MECHANICAL EQUIPMENT BEDROOM 12'-0" LAUNDRYBEDROOM 12'-0" BEDROOM 12'-0" SHOWROOM 14'-0" DINING 17'-0" FOYER 17'-0"COURT YARD KITCHEN 12'-0" FAMILY 12'-0" POOL ROOM 12'-0" MECH COVERED PATIO 1" 8' -5" 1" 9' -0"1"3' -1"1" 0' -10" POOL BATH 12'-0" CHEF KITCHEN 12'-0" GUEST BEDROOM 12'-0" W.I.C. 12'-0" ELEV POWD STAIRS POOL EQUIP3' - 0"MECHANICAL 13'-0" STORAGE 13'-0" 1" 1' -9"1" x 2' -1"1" x 2' -1"1" x 2' -1"1" x 2' -1"1" x 2' -1"1" 4' -7"1"9' -0"1"8' -6"1"14' -0"1"15' -0"1"14' -0"1" 9' -10" 1" 9' -10" 1" 9' -10" 1" 9' -10" 1" 4' -2" 1" 4' -2" 1" 4' -2" 1" 4' -2"3' - 0"8' - 1"WINE 12'-0" 1" Riser 1" Water Meter Relocated jd@jdmechanical.co Scale Project number Date Drawn by Checked by 82579 Fleming Way Suite DIndio Ca. 92201(760) 775-6220C-16 License # 1020141MECHANICALINC1/8" = 1'-0"1/5/2022 9:13:55 AMFP-2 1st Floor Piping Plan 1st Correction Project Number MADISON LOT 100 10-25-21 JA JDNEW RESIDENCE81560 Baffin AveLa Quinta, Ca. 922531/8" = 1'-0"1 1st Floor Piping Plan Sprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 83 Senju 1/2 Light Concealed Temperature - 162 Finish - B Quick Response Model - Mirage SIN - SS8464 K Factor - 4.9 SS8464 4.9 1/2" 162 °F 18 Senju 1/2 Light Pendent Temperature - 205 Finish - C Special Response Model - Micromatic SIN - SS8464 K Factor - 4.9 SS8464 4.9 1/2" 205 °F : 101 Total No. of Sprinklers: 101 201202 203 SPRINKLER PIPEINSULATION BOTTOM CORD OF ROOF TRUSS OR CEILING JOIST PIPE INSULATION DETAIL www.cadmando.co.uk These blocks were brought to you by CADBlocksFree.com.For all of your 2D & 3D CAD outsource requirements visit us: C A D M A N D O www.cadblocksfree.com COVER WITH HINGED LID FINISHED GRADE DISC-TYPE WATER METER PLUG VALVE(TYP.)UNION(TYP.) CPVC HANGERS NO SCALE TOLCO FIG. 24 DOUBLE-FASTENER SIDE-MOUNT HANGER (OR EQUAL) SELF-DRILLING HEX HEAD SCREW TOLCO FIG. 23 DOUBLE-FASTENER STRAP TYPE HANGER (OR EQUAL) TOLCO FIG. 28M OFFSET HANGER (OR EQUAL) TOLCO FIG. 22 SINGLE-FASTENER STRAP-TYPE HANGER (OR EQUAL) TOLCO FIG. 28 DOUBLE-FASTENER STAND-OFF HANGER (OR EQUAL) TOLCO FIG. 29 DOUBLE-FASTENER DOUBLE OFFSET HANGER (OR EQUAL) CPVC HANGER SPACING PIPE SIZE 11/4" 1" MAXIMUM SUPPORT SPACING 6'-6" 6'-0" 2"8'-0" 11/2"7'-0" Water Supply Information Static Pressure: Residual Pressure: Residual Flow: Additional Hose Flow: 78.35 psi 58.19 psi 41 GPM 0 GPM Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-1 2 Gpm/SqFt 512 Max SqFt 31.0068 GPM 54.2651 Psi 5 GPM 0 GPM MASTER BEDROOM 10'-0" W.I.C 10'-0" GYM 10'-0" STAIRS ELEV HIS 10'-0" HERS 10'-0" W.C. W.C. MASTER DECK 1" 8' -0" 1" 8' -0" 1" 5' -3" 1" 1' -11" 1" 1' -6" 1" 4' -0" 1" 7' -9" 1" 2' -5"1"13' -0"1" 14' -0" 1" 8' -0" 1" 8' -0" 1" 10' -0" 1" 8' -0" 1" 7' -6" 1" 8' -6" 1" 3' -6" 1" 8' -9" 1" 4' -3" 1" 4' -3" 1" 3' -3"1"8' -1"1" 2' -1" 1" 4' -0"1"16' -0"1" 2' -1" 1" 3' -8" 1" 8' -11" 1" 15' -11" 1" 6' -0" 1" 7' -8" 1" 6' -0" 1" 1' -11"1"8' -3"1" 10' -0" 1" 3' -11" 1" 3' -3" 1" 2' -2" 1" 3' -9" 1" 5' -3" 1" 3' -0"1" x 12' -0"1" 3' -0" DOWN TO 1st FLOOR SEE SECTION 1 VIEW DOWN TO 1st FLOOR Calc-1 Supply Point WM 1 9 11 10 12 43 5 DOM 1" x 13' -5"1" x 4' -7"1" RISER1" x 12' -0"1"3' -11"1" 1' -11"2"39' -2"2" 3' -10"2"70' -5"1" 1' -8"1"7' -6"1" 61' -0"1"1' -6"1" 14' -6"1"8' -6"1" 21' -8"1"14' -6"1" 0' -9"1"13' -7"1" x 12' -0"1" x 0' -7"1"52' -7"1" 4' -2"1" x 12' -7"1"10' -11"6 BOR TOR 2 Fire Sprinkler Riser Detail TOR BOR Domestic Supply Check Flow Control 1" CPVC Flow Switch Note Wiring by Others 300psi Gage Sprinkler Box with Wrench & two Sprinkler Heads Each Type 1/2" Drain to Outside1"1"2" PVC Underground By Others Notification Device Wired by Others not to scale Module Must Connect to the Multi Station Smoke Alarm System and the Fire Sprinkler Flow Switch ( all wiring by others ) jd@jdmechanical.co Scale Project number Date Drawn by Checked by 82579 Fleming Way Suite DIndio Ca. 92201(760) 775-6220C-16 License # 1020141MECHANICALINCAs indicated 1/5/2022 9:16:10 AMFP-3 2nd Floor Piping Plan 1st Correction Project Number MADISON LOT 100 10-25-21 JA JDNEW RESIDENCE81560 Baffin AveLa Quinta, Ca. 922531/8" = 1'-0"1 2nd Floor Piping Plan Sprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 83 Senju 1/2 Light Concealed Temperature - 162 Finish - B Quick Response Model - Mirage SIN - SS8464 K Factor - 4.9 SS8464 4.9 1/2" 162 °F 18 Senju 1/2 Light Pendent Temperature - 205 Finish - C Special Response Model - Micromatic SIN - SS8464 K Factor - 4.9 SS8464 4.9 1/2" 205 °F : 101 Total No. of Sprinklers: 101 JD Mechanical Fire 82579 Fleming Way Suite D Your Street Address 2 Indio, Ca. 92201 760-775-6220 Job Name : Madison Lot 100 2nd Try Drawing : Location : 81560 Baffin Ave Remote Area : Calc-1 Contract : Data File : Madison Lot 100 2nd Try Area Calc-1.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical FirePage 1 Madison Lot 100 2nd TryDate 10203040E50R60U70S80S90E100R110P12013014015010 20 30 40 50 60 70 80 90FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 78.35 C2 - Residual Pressure: 58.19 C2 - Residual Flow : 41 D1 - Elevation : 12.642 D2 - System Flow : 31.007 D2 - System Pressure : 54.265 Hose ( Demand ) : _______D3 - System Demand : 31.007 Safety Margin : 12.061 D1D2Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical FirePage 2 Madison Lot 100 2nd TryDate Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 3 Madison Lot 100 2nd Try Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure WM 78.35 58.19 41.0 66.326 31.01 54.265 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 9 26.19 4.9 7.04 13.0 0.05 256 10 27.0 7.24 11 27.0 8.21 2 27.0 10.75 TOR 15.0 41.19 DOM 1.6 49.36 5.0 BOR -3.0 53.13 6 -3.0 54.26 WM -3.0 54.27 1 26.19 4.9 7.04 13.01 0.05 256 3 27.0 7.24 4 27.0 7.89 5 27.0 8.16 12 27.0 8.04 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 4 Madison Lot 100 2nd Try Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 9 26.19 4.90 13.00 1 N 7.0 10.820 150 7.040 to 7.000 -0.351 10 27 13.0 1.101 17.820 0.0307 0.547 Vel = 4.38 10 27 -0.91 1 O 5.0 28.170 150 7.236 to 3R 3.0 8.000 0.0 11 27 12.09 1.101 36.170 0.0268 0.970 Vel = 4.07 11 27 3.87 1 2R 2.0 30.710 150 8.206 to 2O 10.0 26.000 0.0 2 27 15.96 1.101 2N 14.0 56.710 0.0448 2.543 Vel = 5.38 2 27 10.05 1 R 1.0 157.230 150 10.749 to 10N 70.0 71.000 5.197 TOR 15 26.01 1.101 228.230 0.1106 25.244 Vel = 8.77 TOR 15 0.0 1 N 7.0 13.400 150 41.190 to R 1.0 8.000 5.804 DOM 1.6 26.01 1.101 21.400 0.1106 2.366 Vel = 8.77 DOM 1.6 + 5.00 5.00 1 N 7.0 4.600 150 49.360 to 7.000 1.992 BOR -3 31.01 1.101 11.600 0.1532 1.777 Vel = 10.45 BOR -3 0.0 2 2N 22.0 114.020 150 53.129 to 22.000 0.0 6 -3 31.01 2.003 136.020 0.0083 1.130 Vel = 3.16 6 -3 0.0 1.5 0.260 150 54.259 to 0.0 WM -3 31.01 1.598 0.260 0.0231 0.006 Vel = 4.96 0.0 WM 31.01 54.265 K Factor = 4.21 1 26.19 4.90 13.01 1 N 7.0 10.820 150 7.045 to 7.000 -0.351 3 27 13.01 1.101 17.820 0.0307 0.547 Vel = 4.38 3 27 0.90 1 2R 2.0 11.680 150 7.241 to O 5.0 7.000 0.0 4 27 13.91 1.101 18.680 0.0347 0.649 Vel = 4.69 4 27 -6.39 1 N 7.0 11.440 150 7.890 to O 5.0 13.000 0.0 5 27 7.52 1.101 R 1.0 24.440 0.0111 0.272 Vel = 2.53 5 27 2.52 1 5N 35.0 95.990 150 8.162 to O 5.0 40.000 0.0 2 27 10.04 1.101 135.990 0.0190 2.587 Vel = 3.38 0.0 2 10.04 10.749 K Factor = 3.06 10 27 0.91 1 2O 10.0 13.000 150 7.236 to 10.000 0.0 3 27 0.91 1.101 23.000 0.0002 0.005 Vel = 0.31 0.0 3 0.91 7.241 K Factor = 0.34 4 27 6.40 1 2R 2.0 16.270 150 7.890 to 2.000 0.0 12 27 6.4 1.101 18.270 0.0083 0.151 Vel = 2.16 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 5 Madison Lot 100 2nd Try Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 12 27 -2.53 1 2R 2.0 36.580 150 8.041 to N 7.0 14.000 0.0 11 27 3.87 1.101 O 5.0 50.580 0.0033 0.165 Vel = 1.30 0.0 11 3.87 8.206 K Factor = 1.35 12 27 2.52 1 3O 15.0 43.010 150 8.041 to 3N 21.0 39.000 0.0 5 27 2.52 1.101 3R 3.0 82.010 0.0015 0.121 Vel = 0.85 0.0 5 2.52 8.162 K Factor = 0.88 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. They are decorative and fast responding. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows for easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for residential occupancies and is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar1/2) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents to escape or evacuate in case of a fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. “Lead Free” is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA’s Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. Approvals: Sprinkler Identification Number (SIN): Maximum Working Pressure: Discharge Coefficient (Nominal K-Factor): Temperature Rating: Color Code (Sprinkler) Color Code (Cover Plate) Vertical Adjustment: Cover Plate Finishes: Standard Finishes- Custom Finishes- Please see chart on Page 8 for more detail. Physical Characteristics: In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is reached, internal components of the sprinkler fall apart. This leads to the water flow to be distributed on the affected fire area. (Ref. Figure 2) DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. Locations of sprinklers must follow the obstruction rules of NFPA 13, 13D and 13R for Residential Sprinklers. The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Refer to NFPA 13D, 13R or 13 for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to the exposure of a heat source other than an actual fire. Available Sprinkler Temperature Ratings Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating Maximum Ambient Ceiling Temperature Temperature Rating of the Cover Plate Assembly Ordinary 162°F (72°C) 100°F (38°C) 140°F (60°C) Intermediate 175°F (79°C 150°F (66°C) 140°F (60°C) 1) Intermediate 175°F (79°C) 150°F (66°C) 162°F (72°C) 1) Maximum ambient temperature for the Cover Plate Assembly is 100°F (38°C). Model RC-RES sprinklers should not be installed where they may be subjected to a corrosive environment including the following: Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) – Solder Joint) All residual flux must be removed from the interior and exterior of the copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and/or leakage in the sprinkler system. The minimum required sprinkler flow rates for systems designed to NFPA 13D or 13R are given in TABLE A as a function of temperature rating and the maximum allowable coverage area. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of “design sprinklers” as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in TABLE A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. A minimum discharge of 0.1GPM/sq.ft. [4.07LPM/sq.m] over the “design area” comprised of the four most hydraulically demanding sprinklers for the actual coverage area being protected by the four sprinklers. For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R or 13 as applicable. Ordinary Temperature Rating 162°F (72°C) Intermediate Temperature Rating 175°F (79°C) Maximum Coverage Area(a) Ft. × Ft. (m ×m) Maximum Spacing Ft. (m) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) 12×12 (3.7×3.7) 12 (3.7) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 14×14 (4.3×4.3) 14 (4.3) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 15×15 (4.6×4.6) 15 (4.6) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 16×16 (4.9×4.9) 16 (4.9) 13 (49.2) 7.0 (0.48) 14 (53.0) 8.2 (0.57) 18×18 (5.5×5.5) 18 (5.5) 17 (64.3) 12.0 (0.83) 18 (68.1) 13.5 (0.93) 20×20 (6.1×6.1) 20 (6.1) 21 (79.5) 18.4 (1.27) Smooth Ceilings 3/8 to 7/8 Inches. Beamed Ceilings per NFPA 13D, 13R or 13 Installed in beam 3/8 to 7/8 inches below bottom of beam. Concealed 8 (2.4) (a) For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. TABLE A) The Model RC-RES must be installed in accordance with the following instructions: The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inches (50.8mm) as shown in Figure 3. With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Socket NR-H or Ratchet (3/8” drive) & Socket NR-H Combination (Ref. Figure 4). The teeth of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). If desired, the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with a 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the “Vertical Adjustment” indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just has contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot contact the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6. The following instructions must be implemented for the maintenance and service of the Model RC-RES. When placing an order, please contact a local distributor with the following information (Model Name, Temperature Rating and Finish). Model: RC-RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162°F (72°C) or 175°F (79°C) ) 2-5/8 inch (68mm) or 3-1/4 inch (83mm) or 2-5/8 inch square (68mm), Order Separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. Standard Finishes Custom Finishes 2-5/8" Round, 140°F - - - - - - 3-1/4" Round, 140°F 2-5/8" Square, 140°F - - - - - - - 2-5/8" Round, 162°F - - - - - - - 3-1/4" Round, 162°F - - - - - - - Socket NR-H For use with a 3/8” drive ratchet (not included) Socket NR-H Plastic For use with a 1/2” drive ratchet (not included) Cap Remover RC OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org January 12, 2022 J D Mechanical Fire Inc 82579 Fleming Way #D Indio, CA 92201 Re: Residential Fire Sprinkler Plan Review – MADISON CLUB – LOT 100 FSS2021-0290 / 81560 BAFFIN AVE, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 81560 BAFFIN AVE PERMIT#: FSS2021-0290 DATE ISSUED: 1/12/2022 DESCRIPTION: MADISON CLUB – LOT 100 CONTRACTOR: J D MECHANICAL FIRE INC HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. 1 Ferguson, Bryttany@CALFIRE Subject:FSS2021-0290 - ASHER - OH SPRINKLER ROUGH/HYDRO Location:81560 BAFFIN AVE Start:Thu 1/20/2022 9:30 AM End:Thu 1/20/2022 10:30 AM Recurrence:(none) Meeting Status:Accepted Organizer:Jose Delgado Required Attendees:Jose Delgado; Kohl Hetrick Optional Attendees:Julia I. Aggreh; Diaz, Ruben@CALFIRE; Ferguson, Bryttany@CALFIRE Categories:LQ INSPECTION Rep. Name: Co. Name: Phone#: Cell#: CrossSt: HYDRANT SYSTEM PASS FAIL FIRE ALARM PASS FAIL Thrust block pre-pour Rough-wire inspection Underground rough Function test Underground hydro Duct detectors/velocity Flush 24 hr. battery test Final Sprinkler monitoring SPRINKLER U.G. Final Thrust block pre-pour SPECIAL SUPPRESSION Underground rough Door fan test Underground hydro Abort test Flush Mechanical shutdown Final Detector test FIRE SPRINKLER Deluge/pre-action Weld inspection Final Overhead rough piping UST/AST TANK Overhead hydro Installation UG flush / OK to connect Removal Main drain/Inspect. Test Emergency shut off High pile storage Primary piping In-rack sprinklers Secondary piping Hose racks Dispensers & shear valves Final Final KITCHEN HOOD EXTINGUISHING MISC. INSPECTION Detection system Spray booths Function Test Hood/duct extinguishing Gas/Electrical shut-off High pile rack storage Nozzle model/placement H.P. vents/access/corridors Fire alarm connection Tract access/hydrant verification Final Other: FIRE & LIFE SAFETY INSPECTION SPRAY BOOTHS KNOX SYSTEM Installation Building Knox box Air flow test Gate access Knox box/padlock 2 Thank you, Mechanical interlock BUILDING INSPECTIONS Extinguishing system T/I final Fire alarm connection Shell final Final Final for occupancy Start Time: Finish Time: FSS2021-0290 OH ROUGH & HYDRO SPK INSPECTION PLANS ON SITE; 1 HEAD ADDED IN FAMILY RM AND 1 HEAD ILLIMINATED IN BUNK RM; COVERAGE APPROVED; APPROVED OH ROUGH AND SIGNED JOB CARD; BF Start Time: Finish Time: 3 Bryttany Ferguson Fire Systems Inspector/Office of the Fire Marshal CAL FIRE/Riverside County Fire Department Proudly serving Riverside County Main: 760-863-8886 Cell: 760-217-0532 77933 La Montanas Rd. Ste. 201, Palm Desert, CA 92211 Bryttany.Ferguson@fire.ca.gov | www.rvcfire.org The Office of the County Fire Marshal is committed to facilitating fire and life safety solutions by empowering its employees to serve our community through innovation and partnership. Warning: this message is from an external user and should be treated with caution. Advise Jose of any clearances or corrections Fire Admin Assistant – Jose Delgado – 760-777-7128 - jodelgado@laquintaca.gov -----Original Appointment----- From: Jose Delgado <jodelgado@laquintaca.gov> Sent: Wednesday, January 12, 2022 1:54 PM To: Jose Delgado; Hetrick, Kohl@CALFIRE Cc: Julia I. Aggreh Subject: FSS2021-0290 - ASHER - OH SPRINKLER ROUGH/HYDRO When: Thursday, January 20, 2022 9:30 AM-10:30 AM (UTC-08:00) Pacific Time (US & Canada). Where: 81560 BAFFIN AVE Warning: this message is from an external user and should be treated with caution. Brian 760.832.2735