FSS2022-0067Description: GODBER / FIRE SPRINKLERS / BRES2021-0700
Type: FIRE SPRINKLER (WEB)
Subtype: RESIDENTIAL - CUSTOM Status: FINALED
Applied: 3/2/2022 EPRS
HOMES
Approved: 5/9/2022 KHET
Parcel No: 777420003 Site Address: 53374 VIA DONA LA QUINTA,CA 92253
Subdivision: TR 29894-4
Block: Lot: 20
Issued: 6/7/2022 ONLINE
Lot Sq Ft: 0
Building Sq Ft: 0 Zoning:
Finaled: 2/21/2023 LRO
Valuation: $4,100.00
Occupancy Type: Construction Type:
Expired:
No. Buildings: 0
No. Stories: 0 No. Unites: 0
Details: Fire Sprinkler Residential
259 �
/mil
\- �/
29 68
i Applied to Approved
Approved to Issued
Issued to Finaled
ADDITIONAL
maillmll'. •0191kelcrm
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
CONTRACTOR REQUESTED FINAL INSPECTION. PERMIT
EXPIRED AS OF 12/11/22 (6 MOS FROM DATE OF LAST
APPROVED INSPECTION). ADDED EXTENSION FEE OF $88 AND
EXTENDED PERMIT TO 2/17/23 SO CONTRACTOR CAN PAY
FEE VIA ETRAKIT. WILL ALSO REQUIRE AN EXTENSION
NOTE
JOSE DELGADO
2/15/2023
2/16/2023
REQUEST LETTER FROM CONTRACTOR. OK TO EXTEND PER
KOHL.
FEES HAVE BEEN PAID AND CONTRACTOR PROVIDED
EXTENSION REQUEST. EXTENDING PERMIT FOR ANOTHER 6
MONTHS.
CONDITIONS
Printed: Wednesday, April 05, 2023 9:48:06 AM 1 of 5
WsYsrEMS
NAME TYPE
NAME
ADDRESSI
CONTACTS
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
nicholas Domnick
16224 space drive
moreno valley
CA
92551
(951)807-1347
NICKNAFP@MSN.COM
CONTRACTOR
NICHOLAS DOMNICK FIRE
PROTECTION
16224 SPACE DR
MORENO
VALLEY
CA
92551
(951)807-1347
NICK@NDFIREPROTECT
ION.COM
OWNER
NICHOLAS DOMNICK
16224 space drive
moreno valley
CA
92551
(951)807-1347
NICKNAFP@MSN.COM
FINANCIAL INFORMATION
CLTD
DESCRIPTION
ACCOUNT
CITY
AMOUNT PAID PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
FIRE PERMIT
EXTENSION (ADMIN
101-0000-42420
0
$88.00
$88.00
2/16/23
WEB14377
816284353
CREDIT
nicholas Domnick
EPRS
PROCESSING)
FIRE SPRINKLER
SYSTEMS - SINGLE
101-0000-42421
0
$167.00
$167.00
6/7/22
WEB12021
637548907
ECHECK
nicholas Domnick
EPRS
02
FAMILY DETACHED
FIRE SPRINKLER
SYSTEMS - SINGLE
101-0000-42420
0
$250.00
$250.00
6/7/22
WEB12021
637548907
ECHECK
nicholas Domnick
EPRS
02
FAMILY DETACHED PC
Total Paid for FIRE FEES: $505.00 $505.00
RECORDS
101-0000-42416
0
$11.00
$11.00
6/7/22
WEB12021
637548907
ECHECK
nicholas Domnick
EPRS
MANAGEMENT FEE
02
Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00
TECHNOLOGY
502-0000-43611
0
$5.00
$5.00
6/7/22
WEB12021
637548907
ECHECK
nicholas Domnick
EPRS
ENHANCEMENT FEE
02
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
TOTALS:ML OO $521.00
Lei 2
SEQID
INSPECTION TYPE
INSPECTOR
SCHEDULED
COMPLETED
RESULT
REMARKS
NOTES
DATE
DATE
Printed: Wednesday, April 05, 2023 9:48:06 AM
2of5
CRWSY5TEM5
OVERHEAD ROUGH revised plans and calcs required to be
PIPING KHET 6/14/2022 6/14/2022 APPROVED REVISED PLANS/CALCS reviewed and approved prior to final
inspection request.
OVERHEAD HYRO I KHET 16/14/2022 16/14/2022 I APPROVED
FIRE FINAL" LRO 2/21/2023 2/21/2023 APPROVED
RETURNED
REVIEWS
STATUS
REMARKS
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
NOTES
DATE
1ST FIRE - ETRAKIT
KOHL
3/2/2022
3/16/2022
3/27/2022
REVISIONS REQUIRED
SEE ATTACHMENTS
(2 WK)
HETRICK
1ST PERMIT TECH —
PERMIT TECH
3/2/2022
3/3/2022
3/3/2022
COMPLETE
ETRAKIT (1 DAY)
BUCKET
KOHL
4/11/2022
4/18/2022
5/9/2022
APPROVED
SEE ATTACHMENTS
2ND FIRE (1 WK)
HETRICK
BOND INFORMATION
Attachment Type
CREATED
OWNER
ATTACHMENTS
DESCRIPTION PATHNAME
SUBDIR
ETRAKIT ENABLED
Etrakit Public
GODBER-RES
DOC
3/2/2022
1ST SUBMITTAL CVWD
CONNECTION CHARGE
1
Registration
EST.pdf
DOC
3/2/2022
Etrakit Public
1ST SUBMITTAL
GODBUR RES 1 HEAD
1
Registration
HYDRAULIC 1
CALC.pdf
DOC
3/2/2022
Etrakit Public
1ST SUBMITTAL
GODBUR RES 2 HEAD
1
Registration
HYDRAULIC 2
CALC.pdf
laquinta lot 20
DOC
3/2/2022
Etrakit Public
1ST SUBMITTAL
GODBUR FIRE 1 OF 2
1
Registration
sprinkler plan 1 of 2
Model (1).pdf
Printed: Wednesday, April 05, 2023 9:48:06 AM 3 of 5
WsYsrEMS
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
laquinta lot 20
DOC
3/2/2022
Etrakit Public
1ST SUBMITTAL
GODBUR FIRE 2 OF 2
1
Registration
sprinkler plan 2 of 2
Model (1).pdf
riverside county plan
DOC
3/2/2022
Etrakit Public
1ST SUBMITTAL plan
review form Godbur
1
Registration
review form
Res.pdf
DOC
4/11/2022
Etrakit Public
2 HEAD CALC
GODBUR RES 2 HEAD
1
Registration
CALC W LOOP.pdf
Etrakit Public
GODBUR RES CALC 1
DOC
4/11/2022
1 HEAD CALC
HEAD 20 X 20 WITH
1
Registration
LOOP.pdf
laquinta lot 20
DOC
4/11/2022
Etrakit Public
REVISED FIRE PLAN 2 OF
GODBUR FIRE revised 2
1
Registration
2
OF 2.pdf
laquinta lot 20
DOC
4/11/2022
Etrakit Public
REVISED FIRE PLAN 1 OF
GODBUR FIRE revised 1
1
Registration
2
OF 2.pdf
Etrakit Public
WATER E MAIL FROM
STATIC WATER
DOC
4/11/2022
PRESSURE FROM
1
Registration
CVWD
CVWD.pdf
DOC
2/16/2023
DOSE DELGADO
fss 2022-0067 permit
fss 2022-0067 permit
0
extention letter.pdf
extention letter.pdf
FSS2022-0067 - 1ST
FSS2022-0067 - 1ST
DOC
3/27/2022
KOHL HETRICK
REVIEW - FIRE
REVIEW - FIRE
1
CORRECTIONS.pdf
CORRECTIONS.pdf
FSS2022-0067-
FSS2022-0067-
DOC
5/9/2022
KOHL HETRICK
APPROVED PLANS AND
APPROVED PLANS AND
1
CALCS.pdf
CALCS.pdf
DOC
5/9/2022
KOHL HETRICK
FSS2022-0067 - COA
FSS2022-0067 - COA
1
AND JOB CARD.pdf
AND JOB CARD.pdf
Printed: Wednesday, April 05, 2023 9:48:06 AM 4 of 5
WsYsrEMS
Printed: Wednesday, April 05, 2023 9:48:06 AM 5 of 5
WsYsrEMS
GENERAL NOTES
A. THIS DESIGN & INSTALLATION REFLECTS N.F.P.A. 130, 2016 ED. _
AND LA QUINTA CITY FIRE DEPARTMENT AMENDMENTS.
1. THIS DRAWING SHOWS THE LAY -OUT OF THE SYSTEM AND
INDICATES THE APPROXIMATE LOCATION OF EQUIPMENT
AND PIPING. THE PIPING IS TO BE INSTALLED IN
APPROXIMATELY THE AREA AS INDICATED ON THE 1 -
DRAWINGS. HOWEVER, THE CONTRACTOR SHALL BE
RESPONSABLE FOR ANY MODIFICATIONS AS MAY BE
REQUIRED TO SUIT STRUCTURAL OR JOB CONDITIONS.
CONTRACTOR SHALL FURNISH ALL OFFSETS, ADDITIONAL
FITTINGS, PIPE ADJUSMENTS ETC., AS MAY BE REQUIRED
TO MEET INSTALLATION CONDITIONS.
2, ONLY UL APPROVED AND NFPA LISTED EQUIPMENT
SHALL BE USED. 3. THE CONTRACTOR IS TO REVIEW1 AR
AND VERIFY ALL FIELD G R
CONDITIONS, MEASUREMENTS, PLANS AND STOCK LISTS,GE
4. PENETRATIONS THROUGH FIRE RATED PARTITIONS TO BE
SEALED TO MAINTAIN THE INTEGRITY OF THE PARTITION.
5. CONTRACTOR IS TO PERFORM AND MEET ALL CODE
REQUIRED TESTS, AND FILE A MATERIAL AND TEST
CERTIFICATE PER NFPA $13D.
6. HYDRAULIC PLACARD TO BE PROVIDED AT THE BASE OF
THE RISER ON CALCULATED SYSTEMS. vErvEc
7. ALL HEADS SUBJECT TO MECHANICAL DAMAGE TO BE
PROVIDED WITH HEAD GUARDS.
8, CONTRACTOR IS TO REPORT CONDITIONS REQUIRING
CHANGES FROM PLANS TO THE ENGINEER PRIOR TO
STARTING WORK.
9. SPRINKLER HEAD TEMPERATURE RATINGS TO BE IN A°I0°1°"O°sp'�I°Ily �s d
ACCORDANCE WITH NFPA 13D OR OTHER GOVERNING °
ODE. O acnnon
10. HANGERS ARE TO BE IN ACCORDANCE WITH NFPA 13D. NO. Or 9FNINNILRS
EARTHQUAKE BRACING TO BE PROVIDED WHERE REQUIRED.
11. FLUSHING CONNECTIONS TO BE PROVIDED AT THE ENDS OF Is a 0[slc
CROSSMAINS. .xuw wao 0
12. AUXILIARY DRAINS TO BE PROVIDED WHERE REQUIRED TO °
DRAIN ALL PORTIONS OF THE SYSTEM.
13. RELIEF VALVES ARE TO BE PROVIDED ON GRIDDED Ru DMAND
SYSTEMS. O
14. ALL WORK SHALL BE APPROVED BY AUTHORITIES HAVING n
JURISDICTION. 0
15. SPARE HEAD CABINET WITH REQUIRED # OF HEADS, AND
WRENCH, TO BE PROVIDED.
NOTES TO THE OWNER
THE SPRINKLER SYSTEM MUST BE MAINTAINED AND TESTED
REGULARLY BY YOU OR YOUR AGENTS IN ACCORDANCE WITH NFPA
REQUIREMENTS.
YOU MUST MAINTAIN SUFFICIENT HEAT THROUGHOUT THE
PREMISES TO PREVENT SYSTEM FREEZING.
YOU SHALL INFORM TENANTS OF PROPER CARE NECESSARY TO
THE SYSTEM.IF
THE CONSTRUCTION OR OCCUPANCY IS ALTERED IN ANY WAY,
��RFLMWMAINTAIN
RESTHE
SYSTEM WILL HAVE TO BE UPDATED ACCORDINGLY.
THEFIRE SPRINKLER INSTALLER SHAL PROVIDE TO THE OWNER/
OCCUPANT INSTRUCTIONS ON INSPECTING, TESTING AND MAINTAINING
THE SYSTEM. (NFPA 13-D, SECTION 4.1.1)
NOTE TO PLAN CHECKER
` COPP O
02
INSTALL NEW FIRE SPRINKLERS SYSTEM
ALL PIPE 1" CPVC
10' FLAT CEILINGS U.N.O.
HANGERS PER 2016 NFPA 13D
APN # 777-420-003
�S■,los
/ 4
� , II�II
Ilwll
BA 5 1 0
2 CAR
GARAGE
) xP To axon.
FRONT ELEVATION
PROJECT: OWNER :
GODBUR RESIDENCE M. NERD ME CSF. K-FAC. 1EMP FlN. CT.
53374 VIA DONA DESERT LAND HOLDINGS LLC 10 TYCOLFIICONC. (16'SPAcwc) 1/z a9 15s 'MIT z9
OO irCO LFlI (LAUNDRY ROgA) 1/2 49 175 N 10
LOT 20 HIDEAWAY COUNTRY CLUB 42-335 WASHINGTON ST. STE.F340 I VI FPCO LF II 51Gew°II 1 1/2ez 1 155 BHT 0
LA QUINTA, CA PALM DESERT, CA 92211
TOTAL 39
COURTYARD
�JJ
II
MASTER
-
BEDROOM
-
—II
11-9
H ILL
I"
COVERED
POR as
N.
PATIO
GREATROOM
I" -' uuul�-luu
I�`I
Ell
` SS
DINING
DI NI' L
7�.ITCIEN4
�d0-10
oAv
13-3
KITCHEN
O
O
La
x APPROVED
oxim°om�oime ri�M nal
By:
Kohl Helrickns
REVISED
IER"ITI,FSS2022-00677
E �Fa�ii�4�FA
VICKJ DOM NICKL J
Z
ia8�r "� 0r'1
O
� UN
�O QU
Ul0 m
�aO
LEE F
z�
r0 Op,rj O
6oN xroaauuc NcrtNENcc oxLY) d 0 1 0 Q
DESIGN AND INSTALLATION BY: N.D.F.P
CA LICENSE: #682276
NICIHOLAS DOMNICK FIRE PROTECTION
16224 SPACE DRIVE
MORENO VALLEY, CA
(951) 807-1347
FIRE SPRINKLER PLAN DRAWN BY : NICK
SCALE: 1 4 = ir DATE: 03-01-22 PAGE: 01 OF 02
GENERAL NOTES
A. THIS DESIGN & INSTALLATION REFLECTS N.F.P.A. 13D, 2016 ED.
AND LA QUINTA CITY FIRE DEPARTMENT AMENDMENTS.
1. THIS DRAWING SHOWS THE LAY -OUT OF THE SYSTEM AND
INDICATES THE APPROXIMATE LOCATION OF EQUIPMENT
AND PIPING. THE PIPING IS TO BE INSTALLED IN
APPROXIMATELY THE AREA AS INDICATED ON THE
DRAWINGS. HOWEVER, THE CONTRACTOR SHALL BE
RESPONSABLE FOR ANY MODIFICATIONS AS MAY BE
REQUIRED TO SUIT STRUCTURAL OR JOB CONDITIONS.
CONTRACTOR SHALL FURNISH ALL OFFSETS, ADDITIONAL
FITTINGS, PIPE ADJUSMENTS ETC., AS MAY BE REQUIRED
TO MEET INSTALLATION CONDITIONS.
2. ONLY UL APPROVED AND NFPA LISTED EQUIPMENT
SHALL BE USED.
3. THE CONTRACTOR IS TO REVIEW AND VERIFY ALL FIELD
CONDITIONS, MEASUREMENTS, PLANS AND STOCK LISTS,
4. PENETRATIONS THROUGH FIRE RATED PARTITIONS TO BE
SEALED TO MAINTAIN THE INTEGRITY OF THE PARTITION.
5. CONTRACTOR IS TO PERFORM AND MEET ALL CODE
REQUIRED TESTS, AND FILE A MATERIAL AND TEST
CERTIFICATE PER NFPA #13D.
6. HYDRAULIC PLACARD TO BE PROVIDED AT THE BASE OF
THE RISER ON CALCULATED SYSTEMS.
7. ALL HEADS SUBJECT TO MECHANICAL DAMAGE TO BE
PROVIDED WITH HEAD GUARDS.
8. CONTRACTOR IS TO REPORT CONDITIONS REQUIRING
CHANGES FROM PLANS TO THE ENGINEER PRIOR TO
STARTING WORK.
9. SPRINKLER HEAD TEMPERATURE RATINGS TO BE IN
ACCORDANCE WITH NFPA 13D OR OTHER GOVERNING
CODE.
10. HANGERS ARE TO BE IN ACCORDANCE WITH NFPA 13D.
EARTHQUAKE BRACING TO BE PROVIDED WHERE REQUIRED.
11. FLUSHING CONNECTIONS TO BE PROVIDED AT THE ENDS OF
CROSSMAINS.
12. AUXILIARY DRAINS TO BE PROVIDED WHERE REQUIRED TO
DRAIN ALL PORTIONS OF THE SYSTEM.
13. RELIEF VALVES ARE TO BE PROVIDED ON GRIDDED
SYSTEMS.
14. ALL WORK SHALL BE APPROVED BY AUTHORITIES HAVING
JURISDICTION.
15. SPARE HEAD CABINET WITH REQUIRED # OF HEADS, AND
WRENCH, TO BE PROVIDED.
NOTES TO THE OWNER
THE SPRINKLER SYSTEM MUST BE MAINTAINED AND TESTED
REGULARLY BY YOU OR YOUR AGENTS IN ACCORDANCE WITH NFPA
REQUIREMENTS.
YOU MUST MAINTAIN SUFFICIENT HEAT THROUGHOUT THE
PREMISES TO PREVENT SYSTEM FREEZING.
YOU SHALL INFORM TENANTS OF PROPER CARE NECESSARY TO
MAINTAIN THE SYSTEM.
IF THE CONSTRUCTION OR OCCUPANCY IS ALTERED IN ANY WAY,
THE SYSTEM WILL HAVE TO BE UPDATED ACCORDINGLY.
THE FIRE SPRINKLER INSTALLER SHAL PROVIDE TO THE OWNER/
OCCUPANT INSTRUCTIONS ON INSPECTING, TESTING AND MAINTAINING
THE SYSTEM. (NFPA 13-D, SECTION 4.1.1)
NOTE TO PLAN CHECKER
INSTALL NEW RE
ALL PIPE 1 " CPVC
10 FLAT CEILINGS
SPRINKLERS SYSTEM
U.N.O.
HANGERS PER 2016 NFPA 13D
TOLCO FIG. 23
TOR
FIG. 22 CPVC STRAP
CPVC STRA
O P-----\ 4PIPIN
PVC PIPIN CPVCOMPOSITE WOOD
HEX HEAD SELF
TAPPING SCREWN,--FLEX HEAD SELF
TAPPING SCREW
CPVC PIPING-/
SINGLE FASTENER DOUBLE FASTENER
CPVC PIPE STRAP CPVC PIPE STRAP
FIGURE 22 - CPVC HANGER FIGURE 23 - CPVC HANGER
TAPPING SCREF
CLOSED PVC/CPVC PLASTIC PIPE THROUGH
1-HR. AND 2-HR. GYPSUM WALL ASSEMBLY
F RAIN - rR AND 24R
T -,HD
M/SQ FT.AT AMNf .SEM1AD2
L A,NRA1W
\-OFFSET HANGER
HANGERS ON 9LL , FFDIT 1EW SEM A -A
DROPS OVER 1 -0
A
HEADSET
2
BOARD CLG
J
AJ
NB-1 HEADSET MOUNTING BRACKET
AND NO BLOCK HANGER
HARDENED HEX HEAD SELF THREADING SCREW
IS FURNISHED NTH THE HANGER AND IS THE
MINIMUM FASTENER SIZE ACCEPTABLE
1
0 01
MAXIMUM DISTANCE BETWEEN HANGERS
CPVC PIPIN NOMINAL PIPE 3/4" 1" 1-1/4"1-1/2" 2"
DOUBLE FASTENER SIZE (in.)
CPVC PIPE STRAP
FIGURE 24 -CPVC HANGER COPPER TUBE 8'-0" 8'-0" 10'-0" 10'-0" 12'-0"
CPVC 5'-6" 6'-0" 6'-6" 7'-0" 8'-0"
SCALE
PROJECT:
GODBUR RESIDENCE
53374 VIA DONA
LOT 20 HIDEAWAY COUNTRY CLUB
LA QUINTA, CA
1. CW9M WAIL ASMAY (I-K AID 2-K FK-MWX2-RR Wellz POMM rU TR B ONE OF WE FOLO•D :
A MUM r NAIc1ER aw NASID PPE (am PPMO WBOL
3. FS-NE WAI FBFOAMMM KUIESOIR SFAI.WT
A I0IM M SAB' OFPIII OF SEAIJNf FORA 1-HR. FNE-RAIN&
L INNFM 1-1/4' DU M OF SEAI/NT FOR A 2-HL INE-MIM
I NM: I. AMAAAR SPACE - MNMM 311r. MWAM 1-1/4'. I
2 MAMIM NAMEIFR OF USK - /-3/A'.
SEE NSTAUAI,ON MANUAL FM MMIWMAL MSIMOIS
CLOSED PVC/CPVC PLASTIC PIPE THROUGH
1-HR. AND 2-HR. GYPSUM WALL ASSEMBLY
CPVC DETAILS
OWNER
HYDRAULIC -SYSTEM
This building is protected
by a Hydraulically Designed
Automatic Sprinkler System
LOCATION MOST REMOTE
NO. OF SPRINKLERS 0
BASIS OF DESIGN
1. HAZARD GROUP RESIDENTIAL
2. DENSITY 05
3. DESIGNED AREA OF DISCHARGE 500 SQ. FT.
SYSTEM DEMAND
1. SPRINKLER DISCHARGE
2. RESIDUAL PRESSURE AT
BASE OF RISER
3. DEMAND AT SOURCE
26.5 GPM
44.8 PSI
59.9 PSI @ 31.5 GPM
DESERT LAND HOLDINGS L-L-C
42- 335 WASH N GTON ST. STE. F340
PALM DESERT, CA 92211
NO. IDATE REVISION
SYM. HEAD TYPE ORF. K-FAC. TEMP FIN. CT. 4/11/22 PER CORRECTIONS
0
TYCO LF II CONC. ( 16' SPACING)
1 /2"
4.9
155
WHT
29
0°
TYCO LFII (LAUNDRY ROOM)
1 /2"
4.9
175
WHT
10
TYCO LF II sidewall
1 /2"
4.2
155
WHT
0
TOTAL 39
1" CPVC
TO EXISTING S
-1" CPVC
-T.O.R.
-1" CPVC
PRESSURE GAUGE
N VALVE
TEST
1" CHECK VALVE U RAIN LINE
(RUBBER FACED)
1" CPVC -
BOR
anR
TO DOMESTIC
5 G.P.M. /
-SHUT-OFF VALVE J DOM
C
REMSED
P��oF CAL /� 11
.,tip
00 1••• .• .• .••O
004 ••••t•*•
00 1 J.DOMNICKiO
/ •••.:••••••• C • 16 # ••••••s• /
00� 682276 O `0=
I11%,j •••••••••••• ��dw
w
a
0
NEPTUNE T-10
1" WATER METER
1"-1/2 pvc 1"-1/2 pvc 6 P.S.I. LOSS 1" COPPER L / 1
O SRC �J
5'Lij
DGA M2 65' MAX
Mt 15' 8CITY MAIN
FIRE SPRINKLER RISER DETAIL & UNDERGROUND 0
(FOR HYDRAULIC REFERENCE ONLY)
F RE SPRINKLER PLAN
U
z
OII^`J
U N
LLJ
U
��
zQ
Q
w z
�Q
�0
QU
U� Q
LL1
LLJ
_0
Q
=
\Q
oz
NO
m�
0
0 Q
CD Lid
DESIGN AND INSTALLATION BY: N.D.F.P
CA LICENSE: #682276
NICHOLAS DOMNICK FIRE PROTECTION
16224 SPACE DRIVE
MORENO VALLEY, CA
(951) 807-1347
DRAWN BY : NICK
SCALE: 1 /4" = 1' DATE: 03-01-22 I PAGE: 02 OF 02
Nick Domnick
From: Nancy Munoz <NMunoz@cvwd.org>
Sent: Tuesday, April 5, 2022 11:33 AM
To: Nick Domnick
Cc: Development Services
Subject: Calculated PSI for The Hideaway, 53374 Via Dona, La Quinta
Follow Up Flag: Follow up
Flag Status: Flagged
Nick,
The calculated PSI for the property located at The Hideaway, 53374 Via Dona, La Quinta is nearly 70 psi.
Thank you,
Nawa� K. MOA10Z
Development Service Technician I
ZR
9�13110130
YourWater
is our promise
Coachella Valley Water District
760-398-2651 Ext 3532
www.cvwd.org
"These comments/conditions are valid for one year from the date of this letter/email, including any verbal
representations. Thereafter, CVWD may review and revise the requirements discussed and/or require updated information."
1
0
HYDRAULIC CALCULATIONS FOR
GODBUR RESIDENCE 53374 VIA DONA (THE HIDEAWAY) LA QUINTA, CA
2 HEAD CALC 90% OF AVAILABLE WATER SUPPLY (69-10%)= 62.1
DRAWING NUMBER: 7591 DATE: APR 11, 2022
-DESIGN DATA -
REMOTE AREA NUMBER: 1 REMOTE AREA LOCATION: WORST CASE 2 HEAD CALC
OCCUPANCY CLASSIFICATION: RESIDENTIAL
DENSITY: .05 gpm/sq. ft.
AREA OF APPLICATION: 500 sq. ft.
COVERAGE PER SPRINKLER: 256 sq. ft.
TYPE OF SPRINKLERS CALCULATED: TYCO LF II
NUMBER OF SPRINKLERS CALCULATED: 2
HOSE -STREAM DEMAND: 5 gpm
TOTAL WATER REQUIRED (INCLUDING HOSE): 36.3 gpm
FLOW AND PRESSURE (AT BASE OF RISER): gpm @ psi
TYPE OF SYSTEM: WET
WATER SUPPLY
Source: CITY MAIN Test Date: 1/27/22 Test By: CVWD
Location:53374 VIA DONA
Static: 62 psi Residual: 20 psi Flow: 3000.0 gpm
Source Elevation Relative to Finished Flow Level: ft.
AUTHORITY HAVING JURISDICTION:LA QUINTA FIRE (RIVERSIDE COUNTY)
NOTES:ALL RUN TEES ADDED IN EQUIVELANT FEET OF PIPE.
Calculations performed by HASS under license # 64621467 ,
granted by HRS SYSTEMS, INC.
(Notes continue after pipe calculations results.)
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2
DATE: 4/11/20222 JOBS\JIM SNELLENBURGER\GODBUR LOT 20\GODBUR RES CALC.SDF
JOB TITLE: GODBUR 2 HEAD CALC
WATER SUPPLY ANALYSIS
Static: 62.10 psi Resid: 20.00 psi Flow: 3000.0 gpm
:I I
70.0
60.0
G
A
U 50.0
G
E 40.0
P
30.0
R
E
20.0
S
S
U 10.0
R
E
0.0
LEGEND
1 Available pressure
62.09 psi @ 36.3 gpm
2 i Required pressure
52.18 psi @ 36.3 gpm
Avail. OnSite Demand Press.
62.09 psi @ 31.3 gpm
i Req. OnSite Demand Press.
52.18 psi @ 31.3 gpm
A. Source Supply Curve
B. System Demand Curve
C. Available at Source
s
600900 1200 1500 1800 2100 2400 2700 3000
i
FLOW (GPM)
)_tote: (1) Dashed Lines indicate extrapolated values from Test Results
(2) On Site pressures are based on hose stream deduction at the source
SPRINKLER
SYSTEM
HYDRAULIC
ANALYSIS
Page 3
DATE: 4/11/20222
JOBS\JIM SNELLENBURGER\GODBUR
LOT 20\GODBUR RES CALC.SDF
JOB TITLE:
GODBUR
2 HEAD CALC
NFPA WATER
SUPPLY
DATA
SOURCE
STATIC
RESID.
FLOW
AVAIL.
TOTAL
REQ'D
NODE
PRESS.
PRESS. @
PRESS.
@ DEMAND
PRESS.
TAG
(PSI)
(PSI)
(GPM)
(PSI)
(GPM)
(PSI)
SOURCE
62.1
20.0
3000.0
62.1
36.3
52.2
AGGREGATE FLOW ANALYSIS:
TOTAL FLOW
AT SOURCE
36.3
GPM
TOTAL HOSE
STREAM ALLOWANCE AT SOURCE
5.0
GPM
OTHER HOSE
STREAM ALLOWANCES
5.0
GPM
TOTAL DISCHARGE
FROM
ACTIVE SPRINKLERS
26.3
GPM
NODE ANALYSIS DATA
NODE TAG
ELEVATION
NODE TYPE
PRESSURE
DISCHARGE NOTES
(FT)
(PSI)
(GPM)
M1
101.0
- - - -
47.2
- - -
NOTES
M2
101.0
- - - -
35.2
- - -
NOTES
UGA
101.0
- - - -
34.7
- - -
NOTES
DOM
102.0
HOSE STREAM
34.0
5.0
NOTES
BOR
102.0
- - - -
33.3
- - -
NOTES
TOR
112.0
- - - -
26.1
- - -
NOTES
5
112.0
- - - -
25.2
- - -
NOTES
6
112.0
- - - -
23.6
- - -
NOTES
7
112.0
- - - -
22.4
- - -
NOTES
8
122.0
- - - -
16.1
- - -
NOTES
9
122.0
- - - -
13.6
- - -
NOTES
10
122.0
- - - -
11.8
- - -
NOTES
11
122.0
- - - -
7.7
- - -
NOTES
12
112.0
- - - -
23.6
- - -
13
112.0
- - - -
23.6
- - -
13A
112.0
- - - -
23.6
- - -
13B
112.0
- - - -
23.6
- - -
14
115.0
- - - -
22.3
- - -
15
115.0
- - - -
22.3
- - -
16
112.0
- - - -
23.6
- - -
17
112.0
- - - -
23.6
- - -
18
112.0
- - - -
23.6
- - -
19
112.0
- - - -
23.6
- - -
100
122.0
K= 4.90
7.4
13.3
101
122.0
K= 4.90
7.0
13.0
200
112.0
- - - -
23.6
- - -
SOURCE
100.0
SOURCE
52.2
31.3
SPRINKLER SYSTEM HYDRAULIC ANALYSIS
Page 4
DATE:
4/11/20222
JOBS\JIM
SNELLENBURGER\GODBUR
LOT
20\GODBUR
RES CALC.SDF
JOB TITLE:
GODBUR
2 HEAD
CALC
NFPA
PIPE
DATA
Pipe
Tag
K-fac
Add F1
Add F1
To
Fit:
L
C
(Pt)
Frm Node
E1 (ft)
PT
(q)
Node/
Nom ID
Eq.Ln.
F
(Pe)
To Node
E1 (ft)
PT
Tot.(Q)
Disch
Act ID
(ft.)
T
Pf/ft.
(Pf)
Pipe:
1
Source
0.0
15.00
150
4.9
SOURCE
100.0
52.2
31.3
M2
1.000
2E: 5.4
5.40
0.4
M1
101.0
47.2
31.3
1.025
20.40
0.221
4.5
Pipe:
2
0.0
Fixed Pressure
Loss
Device
M1
101.0
47.2
31.3
UGA
12.0
psi,
31.3 gpm
M2
101.0
35.2
31.3
Pipe:
3
0.0
0.0
65.00
150
0.6
M2
101.0
35.2
31.3
DOM
2.000
2E:15.1
15.11
-0.0
UGA
101.0
34.7
31.3
2.067
80.11
0.007
0.6
Pipe:
4
H.S.
5.0
Disch
5.00
150
0.6
UGA
101.0
34.7
26.3
BOR
2.000
E: 7.6
22.67
0.4
DOM
102.0
34.0
31.3
2.067
T:15.1
27.67
0.007
0.2
Pipe:
5
0.0
0.0
2.00
150
0.8
DOM
102.0
34.0
26.3
TOR
1.000
E: 2.7
2.70
-0.0
BOR
102.0
33.3
26.3
1.025
4.70
0.160
0.8
Pipe:
6
0.0
0.0
10.00
150
7.2
BOR
102.0
33.3
26.3
5
1.000
E: 7.0
15.00
4.3
TOR
112.0
26.1
26.3
1.101
C: 8.0
25.00
0.113
2.8
Pipe:
7
0.0
0.0
1.00
150
0.9
TOR
112.0
26.1
26.3
6
1.000
E: 7.0
7.00
-0.0
5
112.0
25.2
26.3
1.101
8.00
0.113
0.9
Pipe:
8
0.0
0.0
12
8.00
150
1.6
5
112.0
25.2
26.3
7
1.000
T: 6.0
6.00
-0.0
6
112.0
23.6
26.3
1.101
14.00
0.113
1.6
Pipe:
9
0.0
0.0
4.00
150
1.2
6
112.0
23.6
26.3
8
1.000
E: 7.0
7.00
-0.0
7
112.0
22.4
26.3
1.101
11.00
0.113
1.2
Pipe:
10
0.0
0.0
10.00
150
6.3
7
112.0
22.4
26.3
9
1.000
E: 7.0
7.00
4.3
8
122.0
16.1
26.3
1.101
17.00
0.113
1.9
Pipe:
11
0.0
0.0
15.00
150
2.5
8
122.0
16.1
26.3
10
1.000
E: 7.0
7.00
-0.0
9
122.0
13.6
26.3
1.101
22.00
0.113
2.5
Pipe:
12
0.0
0.0
10.00
150
1.8
9
122.0
13.6
26.3
11
1.000
T: 6.0
6.00
-0.0
10
122.0
11.8
26.3
1.101
16.00
0.113
1.8
Notes
SPRINKLER SYSTEM HYDRAULIC ANALYSIS
Page 5
DATE:
4/11/20222
JOBS\JIM
SNELLENBURGER\GODBUR LOT
20\GODBUR
RES CALC.SDF
JOB TITLE:
GODBUR
2 HEAD
CALC
Pipe
Tag
K-fac
Add F1
Add F1
To
Fit:
L
C
(Pt)
Frm Node
E1 (ft)
PT
(q)
Node/
Nom ID
Eq.Ln.
F
(Pe)
To Node
E1 (ft)
PT
Tot.(Q)
Disch
Act ID
(ft.)
T
Pf/ft.
(Pf)
Pipe:
13
0.0
13.0
101
31.00 150
4.2
10
122.0
11.8
13.3
100
1.000
T: 6.0
6.00
-0.0
11
122.0
7.7
26.3
1.101
37.00
0.113
4.2
Pipe:
14
4.90
13.3
Disch
1.00
150
0.3
11
122.0
7.7
0.0
1.000
E: 7.0
7.00
-0.0
100
122.0
7.4
13.3
1.101
8.00
0.032
0.3
Pipe:
15
4.90
13.0
Disch
13.00
150
0.6
11
122.0
7.7
0.0
1.000
E: 7.0
7.00
-0.0
101
122.0
7.0
13.0
1.101
20.00
0.031
0.6
Pipe:
16
0.0
0.0
8.00
150
0.0
6
112.0
23.6
0.0
1.000
E: 7.0
7.00
-0.0
12
112.0
23.6
0.0
1.101
15.00
0.000
0.0
Pipe:
17
0.0
0.0
20.00
150
-0.0
12
112.0
23.6
0.0
1.000
T: 6.0
6.00
-0.0
13
112.0
23.6
0.0
1.101
26.00
0.000
0.0
Pipe:
18
0.0
0.0
24.00
150
-0.0
13A
112.0
23.6
0.0
1.000
T: 6.0
6.00
-0.0
13
112.0
23.6
0.0
1.101
30.00
0.000
0.0
Pipe:
19
0.0
0.0
8.00
150
-0.0
13A
112.0
23.6
0.0
1.000
E: 7.0
7.00
-0.0
200
112.0
23.6
0.0
1.101
15.00
0.000
0.0
Pipe:
20
0.0
0.0
10.00
150
0.0
13A
112.0
23.6
0.0
1.000
2E:14.0
14.00
-0.0
13B
112.0
23.6
0.0
1.101
24.00
0.000
0.0
Pipe:
21
0.0
0.0
5.00
150
-1.3
14
115.0
22.3
0.0
1.000
T: 6.0
6.00
-1.3
13B
112.0
23.6
0.0
1.101
11.00
0.000
0.0
Pipe:
22
0.0
0.0
26.00
150
-0.0
15
115.0
22.3
0.0
1.000
2E:14.0
14.00
-0.0
14
115.0
22.3
0.0
1.101
40.00
0.000
0.0
Pipe:
23
0.0
0.0
20.00
150
-1.3
15
115.0
22.3
0.0
1.000
T: 6.0
6.00
-1.3
16
112.0
23.6
0.0
1.101
26.00
0.000
0.0
Pipe:
24
0.0
0.0
45.00
150
-0.0
17
112.0
23.6
0.0
1.000
T: 6.0
6.00
-0.0
16
112.0
23.6
0.0
1.101
51.00
0.000
0.0
Pipe:
25
0.0
0.0
20.00
150
-0.0
18
112.0
23.6
0.0
1.000
T: 6.0
6.00
-0.0
17
112.0
23.6
0.0
1.101
26.00
0.000
0.0
Notes
SPRINKLER SYSTEM HYDRAULIC ANALYSIS
Page 6
DATE:
4/11/20222 JOBS\JIM
SNELLENBURGER\GODBUR LOT 20\GODBUR
RES CALC.SDF
JOB TITLE:
GODBUR
2 HEAD CALC
Pipe
Tag
K-fac Add F1 Add F1 To Fit:
L
C
(Pt)
Frm Node
E1 (ft)
PT (q) Node/ Nom ID Eq.Ln.
F
(Pe)
To Node
E1 (ft)
PT Tot.(Q) Disch Act ID (ft.)
T
Pf/ft.
(Pf)
Pipe:
26
0.0 0.0
8.00
150
-0.0
19
112.0
23.6 0.0 1.000 E: 7.0
7.00
-0.0
18
112.0
23.6 0.0 1.101
15.00
0.000
0.0
Pipe:
27
0.0 0.0
27.00
150
-0.0
13
112.0
23.6 0.0 1.000 T: 6.0
6.00
-0.0
19
112.0
23.6 0.0 1.101
33.00
0.000
0.0
NOTES
(HASS):
(1)
Calculations
were performed by the HASS 2021 D computer
program
in accordance
with NFPA13 (2020)
under license
no. 64621467 granted by
HRS Systems, Inc.
208 Southside Square
Petersburg, TN 37144
(931) 659-9760
(2)
The system has
been calculated to provide an average
imbalance at
each node of 0.003 gpm and a maximum
imbalance at
any node of 0.086 gpm.
(3)
Total pressure
at each node is used in balancing the system.
Maximum water
velocity is 12.2 ft/sec at pipe 1.
(4)
Items listed
in bold print on the cover sheet
are
automatically
transferred from the calculation report.
(5) Available pressure at source node SOURCE under full flow conditions is
62.09 psi with a flow of 40.65 gpm.
(6) PIPE FITTINGS TABLE
HASS Pipe Table Name: standard
PAGE: F MATERIAL: CPVC HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) F E T R K C G
F45 Ell Tee RunT Kplg ChkVly Gate
1.101 1.40 7.00 6.00 1.70 1.00 8.00 0.40
Notes
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7
DATE: 4/11/20222 JOBS\JIM SNELLENBURGER\GODBUR LOT 20\GODBUR RES CALC.SDF
JOB TITLE: GODBUR 2 HEAD CALC
PAGE: *
MATERIAL: S40 HWC: 120
Diameter
Equivalent Fitting Lengths
in Feet
(in)
E
T L C
B
G A
D
N
Ell
--------------------------------------------------------
Tee LngEll ChkVly
BfyVly
GatVly A1mChk
DPVly
NPTee
F
F45Ell
1.025
1.79
4.47 1.79 4.47
5.36
0.89 8.93
1.79
4.47
0.89
2.067
5.00
10.00 3.00 11.00
6.00
1.00 10.00
10.00
10.00
2.50
0
HYDRAULIC CALCULATIONS FOR
GODBUR RESIDENCE 53374 VIA DONA (THE HIDEAWAY) LA QUINTA, CA
1 HEAD CALC 20 X 20 90% OF AVAILABLE WATER SUPPLY (69-10%)= 62.1
DRAWING NUMBER: 7591 DATE: APR 11, 2022
-DESIGN DATA -
REMOTE AREA NUMBER: 1 REMOTE AREA LOCATION: WORST CASE 2 HEAD CALC
OCCUPANCY CLASSIFICATION: RESIDENTIAL
DENSITY: .05 gpm/sq. ft.
AREA OF APPLICATION: 500 sq. ft.
COVERAGE PER SPRINKLER: 256 sq. ft.
TYPE OF SPRINKLERS CALCULATED: TYCO LF II
NUMBER OF SPRINKLERS CALCULATED: 1
HOSE -STREAM DEMAND: 5 gpm
TOTAL WATER REQUIRED (INCLUDING HOSE): 30.0 gpm
FLOW AND PRESSURE (AT BASE OF RISER): gpm @ psi
TYPE OF SYSTEM: WET
WATER SUPPLY
Source: CITY MAIN Test Date: 1/27/22 Test By: CVWD
Location:53374 VIA DONA
Static: 62 psi Residual: 20 psi Flow: 3000.0 gpm
Source Elevation Relative to Finished Flow Level: ft.
AUTHORITY HAVING JURISDICTION:LA QUINTA FIRE (RIVERSIDE COUNTY)
NOTES:ALL RUN TEES ADDED IN EQUIVELANT FEET OF PIPE.
Calculations performed by HASS under license # 64621467 ,
granted by HRS SYSTEMS, INC.
(Notes continue after pipe calculations results.)
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2
DATE: 4/11/20222 JOBS\JIM SNELLENBURGER\GODBUR LOT 20\GODBUR RES CALC.SDF
JOB TITLE: GODBUR 2 HEAD CALC
WATER SUPPLY ANALYSIS
Static: 62.10 psi Resid: 20.00 psi Flow: 3000.0 gpm
:I I
70.0
60.0
G
A
U 50.0
G 2
E 40.0
P
30.0
R
E
20.0
S
S
U 10.0
R
E
0.0
LEGEND
1 Available pressure
62.09 psi @ 30.0 gpm
2 i Required pressure
46.01 psi @ 30.0 gpm
Avail. OnSite Demand Press.
62.09 psi @ 25.0 gpm
i Req. OnSite Demand Press.
46.01 psi @ 25.0 gpm
A. Source Supply Curve
B. System Demand Curve
C. Available at Source
s
600900 1200 1500 1800 2100 2400 2700 3000
i
FLOW (GPM)
)_tote: (1) Dashed Lines indicate extrapolated values from Test Results
(2) On Site pressures are based on hose stream deduction at the source
SPRINKLER
SYSTEM
HYDRAULIC
ANALYSIS
Page 3
DATE: 4/11/20222
JOBS\JIM SNELLENBURGER\GODBUR
LOT 20\GODBUR RES CALC.SDF
JOB TITLE:
GODBUR
2 HEAD CALC
NFPA WATER
SUPPLY
DATA
SOURCE
STATIC
RESID.
FLOW
AVAIL.
TOTAL
REQ'D
NODE
PRESS.
PRESS. @
PRESS.
@ DEMAND
PRESS.
TAG
(PSI)
(PSI)
(GPM)
(PSI)
(GPM)
(PSI)
SOURCE
62.1
20.0
3000.0
62.1
30.0
46.0
AGGREGATE FLOW ANALYSIS:
TOTAL FLOW
AT SOURCE
30.0
GPM
TOTAL HOSE
STREAM ALLOWANCE AT SOURCE
5.0
GPM
OTHER HOSE
STREAM ALLOWANCES
5.0
GPM
TOTAL DISCHARGE
FROM
ACTIVE SPRINKLERS
20.0
GPM
NODE ANALYSIS DATA
NODE TAG
ELEVATION
NODE TYPE
PRESSURE
DISCHARGE NOTES
(FT)
(PSI)
(GPM)
M1
101.0
- - - -
42.6
- - -
NOTES
M2
101.0
- - - -
30.6
- - -
NOTES
UGA
101.0
- - - -
30.2
- - -
NOTES
DOM
102.0
HOSE STREAM
29.6
5.0
NOTES
BOR
102.0
- - - -
29.2
- - -
NOTES
TOR
112.0
- - - -
23.2
- - -
NOTES
5
112.0
- - - -
22.6
- - -
NOTES
6
112.0
- - - -
21.7
- - -
NOTES
7
112.0
- - - -
21.7
- - -
NOTES
8
122.0
- - - -
17.3
- - -
NOTES
9
122.0
- - - -
17.3
- - -
NOTES
10
122.0
- - - -
17.3
- - -
NOTES
11
122.0
- - - -
17.3
- - -
NOTES
12
112.0
- - - -
20.6
- - -
NOTES
13
112.0
- - - -
18.9
- - -
13A
112.0
- - - -
17.7
- - -
13B
112.0
- - - -
17.8
- - -
14
115.0
- - - -
16.6
- - -
15
115.0
- - - -
16.8
- - -
16
112.0
- - - -
18.2
- - -
17
112.0
- - - -
18.5
- - -
18
112.0
- - - -
18.6
- - -
19
112.0
- - - -
18.7
- - -
100
122.0
- - - -
17.3
- - -
101
122.0
- - - -
17.3
- - -
200
112.0
K= 4.90
16.7
20.0
SOURCE
100.0
SOURCE
46.0
25.0
SPRINKLER SYSTEM HYDRAULIC ANALYSIS
Page 4
DATE:
4/11/20222
JOBS\JIM
SNELLENBURGER\GODBUR
LOT
20\GODBUR
RES CALC.SDF
JOB TITLE:
GODBUR
2 HEAD
CALC
NFPA
PIPE
DATA
Pipe
Tag
K-fac
Add F1
Add F1
To
Fit:
L
C
(Pt)
Frm Node
E1 (ft)
PT
(q)
Node/
Nom ID
Eq.Ln.
F
(Pe)
To Node
E1 (ft)
PT
Tot.(Q)
Disch
Act ID
(ft.)
T
Pf/ft.
(Pf)
Pipe:
1
Source
0.0
15.00
150
3.4
SOURCE
100.0
46.0
25.0
M2
1.000
2E: 5.4
5.40
0.4
M1
101.0
42.6
25.0
1.025
20.40
0.146
3.0
Pipe:
2
0.0
Fixed Pressure
Loss
Device
M1
101.0
42.6
25.0
UGA
12.0
psi,
25.0 gpm
M2
101.0
30.6
25.0
Pipe:
3
0.0
0.0
65.00
150
0.4
M2
101.0
30.6
25.0
DOM
2.000
2E:15.1
15.11
-0.0
UGA
101.0
30.2
25.0
2.067
80.11
0.005
0.4
Pipe:
4
H.S.
5.0
Disch
5.00
150
0.6
UGA
101.0
30.2
20.0
BOR
2.000
E: 7.6
22.67
0.4
DOM
102.0
29.6
25.0
2.067
T:15.1
27.67
0.005
0.1
Pipe:
5
0.0
0.0
2.00
150
0.5
DOM
102.0
29.6
20.0
TOR
1.000
E: 2.7
2.70
-0.0
BOR
102.0
29.2
20.0
1.025
4.70
0.096
0.5
Pipe:
6
0.0
0.0
10.00
150
6.0
BOR
102.0
29.2
20.0
5
1.000
E: 7.0
15.00
4.3
TOR
112.0
23.2
20.0
1.101
C: 8.0
25.00
0.068
1.7
Pipe:
7
0.0
0.0
1.00
150
0.5
TOR
112.0
23.2
20.0
6
1.000
E: 7.0
7.00
-0.0
5
112.0
22.6
20.0
1.101
8.00
0.068
0.5
Pipe:
8
0.0
0.0
8.00
150
1.0
5
112.0
22.6
20.0
12
1.000
T: 6.0
6.00
-0.0
6
112.0
21.7
20.0
1.101
14.00
0.068
1.0
Pipe:
9
0.0
0.0
4.00
150
0.0
7
112.0
21.7
0.0
1.000
E: 7.0
7.00
-0.0
6
112.0
21.7
0.0
1.101
11.00
0.000
0.0
Pipe:
10
0.0
0.0
10.00
150
-4.3
8
122.0
17.3
0.0
1.000
E: 7.0
7.00
-4.3
7
112.0
21.7
0.0
1.101
17.00
0.000
0.0
Pipe:
11
0.0
0.0
15.00
150
0.0
9
122.0
17.3
0.0
1.000
E: 7.0
7.00
-0.0
8
122.0
17.3
0.0
1.101
22.00
0.000
0.0
Pipe:
12
0.0
0.0
10.00
150
0.0
10
122.0
17.3
0.0
1.000
T: 6.0
6.00
-0.0
9
122.0
17.3
0.0
1.101
16.00
0.000
0.0
Notes
SPRINKLER SYSTEM HYDRAULIC ANALYSIS
Page 5
DATE:
4/11/20222
JOBS\JIM
SNELLENBURGER\GODBUR LOT
20\GODBUR
RES CALC.SDF
JOB TITLE:
GODBUR
2 HEAD
CALC
Pipe
Tag
K-fac
Add F1
Add F1
To
Fit:
L
C
(Pt)
Frm Node
E1 (ft)
PT
(q)
Node/
Nom ID
Eq.Ln.
F
(Pe)
To Node
E1 (ft)
PT
Tot.(Q)
Disch
Act ID
(ft.)
T
Pf/ft.
(Pf)
Pipe:
13
0.0
0.0
31.00
150
0.0
11
122.0
17.3
0.0
1.000
T: 6.0
6.00
-0.0
10
122.0
17.3
0.0
1.101
37.00
0.000
0.0
Pipe:
14
0.0
0.0
1.00
150
0.0
11
122.0
17.3
0.0
1.000
E: 7.0
7.00
-0.0
100
122.0
17.3
0.0
1.101
8.00
0.000
0.0
Pipe:
15
0.0
0.0
13.00
150
-0.0
101
122.0
17.3
0.0
1.000
E: 7.0
7.00
-0.0
11
122.0
17.3
0.0
1.101
20.00
0.000
0.0
Pipe:
16
0.0
0.0
8.00
150
1.0
6
112.0
21.7
20.0
13
1.000
E: 7.0
7.00
-0.0
12
112.0
20.6
20.0
1.101
15.00
0.068
1.0
Pipe:
17
0.0
5.0
19
20.00 150
1.8
12
112.0
20.6
15.0
13A
1.000
T: 6.0
6.00
-0.0
13
112.0
18.9
20.0
1.101
26.00
0.068
1.8
Pipe:
18
0.0
20.0
200
24.00 150
1.2
13
112.0
18.9
-5.0
13B
1.000
T: 6.0
6.00
-0.0
13A
112.0
17.7
15.0
1.101
30.00
0.040
1.2
Pipe:
19
4.90
20.0
Disch
8.00
150
1.0
13A
112.0
17.7
0.0
1.000
E: 7.0
7.00
-0.0
200
112.0
16.7
20.0
1.101
15.00
0.068
1.0
Pipe:
20
0.0
20.0
200
10.00 150
0.1
13B
112.0
17.8
-15.0
13
1.000
2E:14.0
14.00
-0.0
13A
112.0
17.7
5.0
1.101
24.00
0.005
0.1
Pipe:
21
0.0
0.0
5.00
150
-1.2
14
115.0
16.6
5.0
13A
1.000
T: 6.0
6.00
-1.3
13B
112.0
17.8
5.0
1.101
11.00
0.005
0.1
Pipe:
22
0.0
0.0
26.00
150
0.2
15
115.0
16.8
5.0
13B
1.000
2E:14.0
14.00
-0.0
14
115.0
16.6
5.0
1.101
40.00
0.005
0.2
Pipe:
23
0.0
0.0
20.00
150
1.4
16
112.0
18.2
5.0
14
1.000
T: 6.0
6.00
1.3
15
115.0
16.8
5.0
1.101
26.00
0.005
0.1
Pipe:
24
0.0
0.0
45.00
150
0.3
17
112.0
18.5
5.0
15
1.000
T: 6.0
6.00
-0.0
16
112.0
18.2
5.0
1.101
51.00
0.005
0.3
Pipe:
25
0.0
0.0
20.00
150
0.1
18
112.0
18.6
5.0
16
1.000
T: 6.0
6.00
-0.0
17
112.0
18.5
5.0
1.101
26.00
0.005
0.1
Notes
SPRINKLER SYSTEM HYDRAULIC ANALYSIS
Page 6
DATE:
4/11/20222 JOBS\JIM
SNELLENBURGER\GODBUR LOT 20\GODBUR
RES CALC.SDF
JOB TITLE:
GODBUR
2 HEAD CALC
Pipe
Tag
K-fac Add F1 Add F1 To Fit:
L
C
(Pt)
Frm Node
E1 (ft)
PT (q) Node/ Nom ID Eq.Ln.
F
(Pe)
To Node
E1 (ft)
PT Tot.(Q) Disch Act ID (ft.)
T
Pf/ft.
(Pf)
Pipe:
26
0.0 0.0
8.00
150
0.1
19
112.0
18.7 5.0 17 1.000 E: 7.0
7.00
-0.0
18
112.0
18.6 5.0 1.101
15.00
0.005
0.1
Pipe:
27
0.0 0.0
27.00
150
0.2
13
112.0
18.9 5.0 18 1.000 T: 6.0
6.00
-0.0
19
112.0
18.7 5.0 1.101
33.00
0.005
0.2
NOTES
(HASS):
(1)
Calculations
were performed by the HASS 2021 D computer
program
in accordance
with NFPA13 (2020)
under license
no. 64621467 granted by
HRS Systems, Inc.
208 Southside Square
Petersburg, TN 37144
(931) 659-9760
(2)
The system has
been calculated to provide an average
imbalance at
each node of 0.006 gpm and a maximum
imbalance at
any node of 0.145 gpm.
(3)
Total pressure
at each node is used in balancing the system.
Maximum water
velocity is 9.7 ft/sec at pipe 1.
(4)
Items listed
in bold print on the cover sheet
are
automatically
transferred from the calculation report.
(5) Available pressure at source node SOURCE under full flow conditions is
62.09 psi with a flow of 35.27 gpm.
(6) PIPE FITTINGS TABLE
HASS Pipe Table Name: standard
PAGE: F MATERIAL: CPVC HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) F E T R K C G
F45 Ell Tee RunT Kplg ChkVly Gate
1.101 1.40 7.00 6.00 1.70 1.00 8.00 0.40
Notes
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7
DATE: 4/11/20222 JOBS\JIM SNELLENBURGER\GODBUR LOT 20\GODBUR RES CALC.SDF
JOB TITLE: GODBUR 2 HEAD CALC
PAGE: *
MATERIAL: S40 HWC: 120
Diameter
Equivalent Fitting Lengths
in Feet
(in)
E
T L C
B
G A
D
N
Ell
--------------------------------------------------------
Tee LngEll ChkVly
BfyVly
GatVly A1mChk
DPVly
NPTee
F
F45Ell
1.025
1.79
4.47 1.79 4.47
5.36
0.89 8.93
1.79
4.47
0.89
2.067
5.00
10.00 3.00 11.00
6.00
1.00 10.00
10.00
10.00
2.50
LA
Nicholas Domnick
Fire Protection
16224 Space Drive
Moreno Valley, CA 92551
Phone: (951) 807-1347
www.ndfireprotection.com
License #C-16 682276
La Quinta Fire
Dear Sir or Madam:
I would like to request an extension to the permit for the residence located at 53374 Via
Dona. Permit number FSS 2022-0067 due to project delays.
Nicholas J. Domnick, owner
NDFP
CAL FIRE - RIVERSIDE UNIT
RIVERSIDE COUNTY FIRE DEPARTMENT
OFFICE OF THE FIRE MARSHAL — LA QUINTA CALIFORNIA
78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074
• www.rvcfire.org
May 9, 2022
Nicholas Domnick Fire Protection
16224 Space Drive
Moreno Valley, CA 92551
Re: Residential Fire Sprinkler Plan Review — GODBER RESIDENCE
FSS2022-0067 / 53374 VIA DONA, LA QUINTA, CA 92253
The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County
Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions.
Permanently marked identification signs shall be attached to all control valves.
The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff:
(a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal
operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the
potential to contact CPVC piping once insulation is installed.
(b) Final inspection
The Fire Department approved plans and conditions letter must be at the job site.
Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for
inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131.
All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal
staff at (760)777-7074.
Kohl Hetrick - Fire Safety Specialist
i6RIVERSIDE COUNTY FIRE PROTECTION PLANNING
RECORD OF INSPECTIONS / PERMIT CARD al�Cv ,uGKCv
THIS CARD IS TO REMAIN ON SITE AT ALL TIMES.—CALIFORNIA!
INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE.
JOB
ADDRESS:
53374 VIA DONA
PERMIT#:
FSS2022-0067
AT ED:
05/09/2022
DESCRIPTION:
GODBER RESIDENCE
CONTRACTOR:
NICK DOMNICK FIRE PROTECTION
HYDRANT SYSTEM
DATE
INITIALS
SPECIAL SUPPRESSION
DATE
INITIALS
Thrust block pre -pour
Door fan test
UG rough piping
Abort test
UG hydro
Mechanical shutdown
Flush
Detector test
Final IF
Deluge/pre-action
SPRINKLER U.G.
Final IF
Thrust block pre -pour
UST/AST TANK
UG rough piping
Installation
UG hydro
Removal
Flush
Emergency shut off
Final IF
Primary piping
FIRE SPRINKLER
Secondary piping
Weld inspection
Dispensers & shear valves
Overhead rough piping
Final IF
Overhead hydro
MISC. INSPECTIONS
UG flush / OK to connect
Spray booths
Main drain/inspectors' test
Hood/duct extinguishing
High pile storage
High pile rack storage
In -rack sprinklers
H.P. vents/access/corridors
Hose racks
Tract access/hydrant verification
Final E F
Access & Address verification
HOOD EXTINGUISHING
OTHER CONST. PERMIT
Detection system
Function test
Gas/electrical shut-off
Nozzle model/placement
Fire alarm connection
Final e F
SPRAY BOOTHS
FIRE CODE PERMIT(S)
Installation
Air flow test
Mechanical interlock
Extinguishing system
Fire alarm connection
Final e F
FIRE ALARM
KNOX SYSTEM
Rough -wire inspection
Building Knox box
Function test
Gate access Knox box/padlock
Duct detectors/velocity
BUILDING INSPECTIONS
24 hr. battery test
T/I final
Sprinkler monitoring
Shell final
Final E F
Final for occupancy
FINAL INSPECTION DATE: INSPECTORS SIGNATURE:
**WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE-
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
INSPECTION NOTES
1. Sway bracing and hangers will be inspected at the time of rough piping inspection.
2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler
Systems)
3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required.
4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test.
5. Contractor shall supply all testing equipment, access and operating instructions at time of test.
6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the
affected system to be covered or hidden.
POLICIES ON FIELD INSPECTIONS
A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when
scheduling inspections. For City of La Quinta inspections call: (760) 777-7131.
B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence
without approved plans.
C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required
to schedule the necessary inspections and be present on site for inspections.
D. RE -INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not
on site or where previously noted corrections have not been completed.
E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into
the structure until clearance has been granted by the Fire Dept and Building Official.
F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance
has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official.
INSPECTION NOTES:
THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE
AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS.
THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180
DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE.
THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE
REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131