Loading...
FSS2022-0073Description: SWENSON / FIRE SPRINKLERS /BRES2016-0240 Type: FIRE SPRINKLER (WEB) Subtype: RESIDENTIAL - CUSTOM Status: ISSUED Applied: 3/10/2022 EPRS HOMES Approved: 4/26/2022 KHET Parcel No: 658200004 Site Address: 77210 LOMA VISTA LA QUINTA,CA 92253 Subdivision: TR28335-R Block: Lot: 1 Issued: ONLINE Lot Scl Ft: 0 Building Scl Ft: 0 Zoning: Finaled: Valuation: $11,000.00 Occupancy Type: Construction Type: Expired: 11/21/2022 KHET No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 1 47 �J Applied to Approved Printed: Wednesday, April 05, 2023 1:16:22 PM 1 of 4 WSYSiEMS CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY FIRE PLAN REVISION 101-0000-42420 0 $167.00 $167.00 5/17/22 WEB11771 637212627 CREDIT simon chavero EPRS SUBMITTALS 23 FIRE SPRINKLER SYSTEMS - SINGLE 101-0000-42421 0 $250.00 $250.00 5/6/22 WEB11664 636978723 CREDIT simon chavero EPRS 19 FAMILY DETACHED FIRE SPRINKLER SYSTEMS - SINGLE 101-0000-42420 0 $250.00 $250.00 5/6/22 WEB11664 636978723 CREDIT simon chavero EPRS 19 FAMILY DETACHED PC Total Paid for FIRE FEES: $834.00 $834.00 RECORDS 101-0000-42416 0 $11.00 $11.00 5/6/22 WEB11664 636978723 CREDIT simon chavero EPRS MANAGEMENT FEE 19 Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY 502-0000-43611 0 $5.00 $5.00 5/6/22 WEB11664 636978723 CREDIT simon chavero EPRS ENHANCEMENT FEE 19 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 00 $850.00 77, SPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES DATE DATE Electrical installation was not yet complete and is required for Rough approval. Insulation is needed throughout for contact OVERHEAD ROUGH KHET 5/16/2022 5/16/2022 DISAPPROVE SEE NOTES hazard mitigation. PIPING D *Prior to Final Inspection request, revised plans and calcs are required for review and approval. OVERHEAD HYRO KHET 5/16/2022 5/16/2022 APPROVED OH HYDRO IS APPROVED ONLY OVERHEAD ROUGH KHET 5/25/2022 5/25/2022 APPROVED PIPING Printed: Wednesday, April 05, 2023 1:16:22 PM 2 of 4 WsYsrEMS I PARENT PROJECTS = I RETURNED STATUS REMARKS REVIEW TYPE REVIEWER SENT DATE DUE DATE NOTES DATE 1ST FIRE - ETRAKIT KOHL 3/10/2022 3/24/2022 4/4/2022 REVISIONS REQUIRED SEE ATTACHMENTS (2 WK) HETRICK 1ST PERMIT TECH — PERMIT TECH 3/10/2022 3/11/2022 3/11/2022 COMPLETE ETRAKIT (1 DAY) BUCKET KOHL 4/5/2022 4/12/2022 4/26/2022 APPROVED SEE ATTACHMENTS 2ND FIRE (1 WK) HETRICK BOND INFORMATION Attachment Type CREATED OWNER ATTACHMENTS DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 3/10/2022 Etrakit Public 1ST SUBMITTAL FP-1 Loma Vista.pdf5ite 1 Registration Plan.pdf DOC 3/10/2022 Etrakit Public 1ST SUBMITTAL VK494 VK-494 4.9 k Res 155 1 Registration deg (11).pdf DOC 3/10/2022 Etrakit Public 1ST SUBMITTAL FP-1 Loma Vista. pdfRCP.pdf 1 Registration DOC 3/10/2022 Etrakit Public 1ST SUBMITTAL FP-2 Loma Vista.pdfPiping 1 Registration Plan.pdf DOC 3/10/2022 Etrakit Public 1ST SUBMITTAL Document.pdfCalc-1 1 Registration HYDRAULIC CALCS (36).pdf Etrakit Public 1ST SUBMITTAL CVWD Water meter paperwork DOC 3/10/2022 with water pressure at 1 Registration CONNECTION meter.pdf DOC 4/5/2022 Etrakit Public Loma 1 Registration Vista. pdf5ite_1.pdf DOC 4/5/2022 Etrakit Public Loma Vista.pdfRCP 1 Registration (1).pdf Printed: Wednesday, April 05, 2023 1:16:22 PM 3 of 4 WsYsrEMS ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 4/5/2022 Etrakit Public Loma Vista.pdfPiping 1 Registration Plan (1).pdf DOC 4/5/2022 Etrakit Public Document.pdfCalc-1 1 Registration (40).pdf FSS2022-0073-1ST FSS2022-0073 - 1ST DOC 4/4/2022 KOHL HETRICK REVIEW FIRE PLAN REVIEW FIRE PLAN 1 CORRECTIONS.pdf CORRECTIONS.pdf FSS2022-0073-1ST FSS2022-0073-1ST DOC 4/4/2022 KOHL HETRICK REVIEW FIRE REVIEW FIRE 1 CORRECTIONS CORRECTIONS LETTER.pdf LETTER.pdf FSS2022-0073- FSS2022-0073- DOC 4/26/2022 KOHL HETRICK APPROVED PLANS AND APPROVED PLANS AND 1 CALC.pdf CALC.pdf DOC 4/26/2022 KOHL HETRICK FSS2022-0073 - COA FSS2022-0073 - COA 1 AND JOB CARD.pdf AND JOB CARD.pdf DOC 5/16/2022 KOHL HETRICK FSS2022-0073 - Insp FSS2022-0073 - Insp 1 Notes - 5-16-2022.pdf Notes - 5-16-2022.pdf Printed: Wednesday, April 05, 2023 1:16:22 PM 4 of 4 WsYsrEMS q . ¢na b 31 m,.arwaa. sy wPmam Gwurcs pm C.u.s �­'IAlnFwl ¢wciael. s. wmrsuapN Dare: water a auppxeaavn puwcwrerma�n mpreet. w B,aW, �en�rMtMr rerowinab�rvm�lrp� b¢waicn�ers ¢nal notmbcNea smnuers rcarpdemiN ce¢oucuan¢nmi aioraae parmanuraaure¢m¢wcuorc. a Pigiw suoP=tea: Pro —1 bewr,Pvrm ena—.1-1n cemoimancemnie 1 pme¢ptnxiear sxeim eea�mmorc enn,r rmm�n aropm�cprevermiaigerleni s Plp rgMca m.Pp. imn. m.riyeacr¢ viaimm� am Plan rmex Purpoaw aqy. rc. ynaa..a.r.n.ii N.rsan.Nra.rrtn.nmall era P a•®re�rn�w. NFPA 13D REFERANCE NOTES I VICINITY MAP Group RJ One and Two Family Dwellings Fire HydnaM Proxrmdy Mitigation Ma" Diala—fiom Ex sting F re Hydrant to all Fire Spnnkler System MidgMkn Required Ezdanor Oround F—walls (%). (2019 CRC R313 2 S R313.2.1) Xs6DM NFPA 13-3133(CFC 5075. 1 Exception) 6wft <X 5900If NFPA 13DIR3133+ firesprinklersin all an66is, bamrooma and covered pli—porchm Same as 900ft * fire sprinklers throughout agiq. BOOR<%512Wfl Fire spiinklem not required in Aoorlceiling assamtikes or combustible ancealed spaces wilhoN access 1200fl <X 51500R asn12W -threefiespnnklmtread cakuletwSame a. Measured Wong Neand arouM the exkdw d ma building ` F- \ , \ it SILVERADO C-16 # 1068664 Simon®sllvereaoflre.com C O U N O ti LLmU)L, 00 �a- E� VJ I- W cu O A O 9 cc O 6 N W LID cc Z Z rJ Q Site Plan 1st Correction Prnea uRae, Project Number 03-09-22 M JA W Sc FP-1 As iMicatetl 1" CPVC Potter Horn Strobe Wired by Others / 0 Module Must Connect to the Multi Station Smoke Alarm System and the Fire Sprinkler Flow Switch ( all wiring by others ) 300psi Gage\ Domestic Check Supply Flow Control \ BOR Fire Sprinkler Riser Detail TOR v Sprinkler Box with Wrench & two Sprinkler Heads Each Type Flow Switch Note Wiring by Others 1/2" Drain to Outside 2"Underground By Others not to scale 10, OFFICE D10'-01, - o 1-1/4" RISER 9� 0118 1" a 10 7 l;P V +� OQ 70.' 1'. 5'. s \B R � h NOTIFICATION DEVICE BY OTHERS TORDONT-') ��. ^ a f 0" y a o GARAGE a^ 3 10 1O'-O" a o 0 co O 4/ O m 0 o .q� Z 1 211) J e ^ Q H� � N Water Supply Information Static Pressure: 74.03 psi Residual Pressure: 56.19 psi Residual Flow: 32 GPM Additional Hose Flow: 0 GPM Fire Protection System Demand: Remote area number: Calc-1 Occupancy classification: R-3 Density: Gpm/SgFt Area of application: 512 Max SgFt No. of sprinklers calculated: 2 Inside Hose Streams: 5 GPM Outside Hose 0 GPM Streams: I otal water required (including hose streams): 31.1873 GPM @ a required system pressure 49.0924 Psi of: so.0" UTILITY 10'-0" GUEST SUITE 10'-0" BATH BEAMS DRILLED BY OTHERS MASTER SUITE 1014° 10'4" O 1 8 lilv II 01" I i II 1 '•" -6. 6" - - M 3'- 5' 0 2'- 2" 4 ^� M BATH b 10'-o" 1" cli 1"I 4'. 6" c V- 2"1 �9 iry / / I �i. I I 1 I I � '— b''\ ' -2 -- ---e — .�� 6'- I 3' 3 ;0,_7„ 8'_2 I I I I I I I I I I I I I I I I Ul " t. b" I 12 10'-6" 1" 1" 1" 06 1" �' T-4o 7'-4 13%0" 5'-0" 14. �" h 5.0. 10" � �+ LIVING SLOPED I I • 10'-6" 1'-6" 15 1" 1• O 1" �I 15'-10" 9'- 0" 5'. 0" I I I I I of I KITCHEN o SLOPED ^� I I I I 3' 9" 10' 6' 6" 4 111 5'-0" 4'-1- I I 4'. 6"%0 0 6 -3 I �+ 1, 10' 6" 01.9. J - - PAN. I I BED 3 14 ' 1o'-0" O 1" 1 PWDR. Calc-1 1 1" O 3- 1" --- OFFICE ------ J -------10'-0" BATH ---- \ I I \ I I \ I J \ \ � I ---------------------- INSPECTORS TEST 1" BED 2 4'-11 10'-0" 1" 12' - 0" 1" 11.3 1" n 3'- 11 � o 11.77 5' 11,�� 6 BATH JQ� 1" 10 1" 1 ill 7' 4 7'-4" 16'-0" -.6 " 1' 1 014" DINING SLOPED h 11" a 01. 4,• 9' '3 0 1" 21.1" 5'- 9" 1 3" 12' 11" V F— 4 FIRE PROTECTION C-16 # 1068664 simon@silveradofire.com L / ■0 L0 N U N 4-0 N 0 M U c0 ■� X LL 0 0 LO En � I 0 0 p 0pp(.0 n�E r*-ft W � IM ■ No. Description Date n Piping Plan w (1) 1 /8" = 1'-0" IU o Z �2. CO of PIPE INSULATION DETAIL w � U 0 ('13 N � INSULATION SPRINKLER PIPE i CID W J "� Ln o o BOTTOM CORD OF ROOF TRUSS OR CEILING JOIST COVER WITH HINGED FINISHED GRADE DISC -TYPE WATER METER UNION(TYP.)— PLUG VALVE(TYP.)� CPVC HANGER SPACING PIPE SIZE MAXIMUM SUPPORT SPACING 2" 8'-0" Tq" 6-6" 6-V SELF -DRILLING HEX HEAD SCREW � 0 o00 0L TOLCO FIG. 28M TOLCO FIG. 23 TOLCO FIG. 24 TOLCO FIG. 22 TOLCO FIG. 28 TOLCO FIG. 29 OFFSET HANGER DOUBLE -FASTENER DOUBLE -FASTENER SINGLE -FASTENER DOUBLE -FASTENER DOUBLE -FASTENER (OR EQUAL) STRAP TYPE HANGER SIDE -MOUNT HANGER STRAP -TYPE HANGER STAND-OFF HANGER DOUBLE OFFSET HANGER (OR EQUAL) (OR EQUAL) (OR EQUAL) (OR EQUAL) (OR EQUAL) PVC HANGERS NO SCALE Sprinkler Schedule No. of SIN Orifice Sprklrs Description (Hydratec) K-Factor Size Temp 52 Viking 1/2 Light Concealed Temperature -155 Finish - B Quick Response Model - Mirage VK494 4.9 1/2" 155 °F SIN - VK494 K Factor - 4.9 26 Viking 1/2 Light Pendent Temperature -175 Finish - C Special Response Model - VK494 4.9 1/2" 175 °F Micromatic SIN - VK494 K Factor - 4.9 78 Total No. of Sprinklers: 78 j M Z w r-, a z ti Q Piping Plan 1st Correction Project number Project Number Date 03-09-22 Drawn by JA Checked by SC FP-2 Scale As indicated N Water Meter Designed at 30' Below Bottom of Riser Supply Point wM n UG U 1/16" = 1'-0" S'_21, Riverside County Fire Department Office of the Fire Marshal 2300 Market St, Ste 150, Riverside, CA 92501 Ph (951) 955-4777 Fax (951) 955AM6 Technical Policy itle: One- and Two -Family Dwellin s Fire Hydrant Proximity Mitigation Matrix 3chnical Policy: # TP 16-002 Effective Date: 08/08/2016 Revised Date: 01/07/202C ode References: 2019 California Fire Code, Sections 1.11.2.4, 104.1, 104.9, 507, California esidential Code Section R313.2, R313.2.1 and R313.3 and NFPA 13D 2016 edition Group R-3 One and Two Family Dwellings Fire Hydrant Proximity Mitigation Matrix Distance from Existing Fire Hydrant to all Fire Sprinkler System Mitigation Required Exterior Ground Floor Walls (X)II (2019 CRC R313.2 & R313.2.1) X :5 600ft NFPA 13D/R313.3 (CFC 507.5.1 Exception) 600ft < Xs 900ft NFPA 13D/R313.3 + fire sprinklers in all closets, bathrooms and covered patios/porches Same as 900ft + fire sprinklers throughout attic. 900ft < X 1200ft Fire sprinklers not required in floor/ceiling assemblies or combustible concealed spaces without access 1200ft < X 5 1500ft Same as 1200ft + three fire sprinkler head calculation I a_ Measured along the access road/driveway and around the exterior of the building I o \; . L4'i \•1 '6''_ OII I 8'-3" 7'-3" 3'-8" 10'-9" 4'-6" 11 5'-11" 61, O +l 0 4 -—�— T - 11 "1 3'-10" 3'-9■ 1� M ,.• C Y ■U ■ U .0 1 IIIM 1 1411r1 1111 1 1�1� 1�1�1� r 1111 � 1+1� � 1111 �I � 1 11� mail mill Ile- 5,_51I 5'-7 RCP Sprinkler Schedule No. of SIN Orifice Sprklrs Description (Hydratec) K-Factor Size Temp 52 Viking 1/2 Light Concealed Temperature -155 Finish - B Quick Response Model - Mirage VK494 4.9 1/2" 155 OF e SIN - VK494 K Factor - 4.9 26 Viking 1/2 Light Pendent Temperature -175 Finish - C Special Response Model - VK494 4.9 1/2" 175 OF 411 Micromatic SIN - VK494 K Factor - 4.9 : 78 Total No. of Sprinklers: 78 4 SILVEPADO — FIRE PROTECTION — C-16 # 1068664 simon@silveradofire.com .O L0 � N U N N O • -r-- M Lr) (.)(.0 a) X� LL O a) LO En (n I O 00 -0pp(.0 Co r*-ft Cl) No. Description Date LJJ � U 0 O Z >U (a O o 0 — c� E N O 00 W .� O co j M Z Z ti Q RCP 1st Correction Project number Project Number Date 03-09-22 Drawn by JA Checked by SC FP-3 Scale As indicated �i)jATER Residential Connection Charge Estimate June 8, 2021 Customer Name: Case Swenson Phone No. (408) 947-1100 Parcel No. 658-200-004 Geo. 05-06-36-2 Address: 77210 Loma Vista, La Quinta LID: 486574 Block No. Lot No. 1 Size of Lot: 137,650 sq. ft. Tract No. TR 28335-R Type of Service: R-1: Duplex: Triplex: Apts:� SWSC: $ 38,608.88 Acres: 3.16 SWSC: $12,218.00 /acre WSBFC: $ 3,707.00 SCC: $ 4,851.00 Treatment: $2,436/edu Collection: $2,415/edu Meter: $ - Meter Size: 1 1/2 inch Meter surcharge: $ 8,621.00 Service Size: 2 inch Service: $ - Meter & Service: $ 4,790.00 Backflow: $ - Other: $ Sewer Lateral: $ Total: $ LNDSCPE PLNS APPRVD. Per calculations, a 1.5" Srvc w/ 1" Mtr is approved. Customer has requestedto have a 2" Srvc with 1- TR 28335-R. Dwg. 47282 proposes the installation of a 2" wtr sry and Dwg. 47284 the indemnity of the existing 4" sewer lateral after property line. F% ZO - It 409 4 —L Technician: Ruben Montiel Fees Approved by: Date: Information Supplied By Customer CVWD System Data Domestic Water Demand* Service Connection** Max. Flow= 12 gpm Max. Flow*= 31.5 gpm Min. Pressure= 50 psi Inlet Pressure 1= 74.03 psi Fire Sprinkler Demand* Outlet Pressure= 56.19 pSi Max. Flow= 31.5 gpm Min. Pressure= 28 psi Meter Size = 1 inch System Type: El Service Size= 1 1/2 inch Multi Stand Alone 1 Prior to Pressure Regulating Valve ** For Calculation Purposes- Service Connection Includes: * CVWD USES WORST CASE CONDITION Service Connection Pipe=L', Meter Stop, Meter, Check Valve & Shut Off Valve Calculations: E�c`I�( 1 "METER 11/2 "SERVICE Pz= Lower La Quinta �Q ��C1 LUAle Fy� Ps= 74.03 > 60 psi HGL= 235 y�" ��' ti ,. HL-meter= 6.42 RES.#= 6630-1 au r^� c� C 91620 � ' L-valves etc.= 11.42 RES./HT= 32 J EXP.�~ Po= 56.19 > 28 psi PROP. ELEV.= 80 * �� Max.flow 31.50 GPM Ps is OK �4TCIV��f A��ED OK to provide service OF C TRY: Fire Sprinkler Demand Appoved by: Date: The meter sizing is for plan check purposes only. The ultimate responsibility resides with the Engineer -of -Record for the project. Hydraulic Calculations by HydraCALC Silverado Fire Protection PO Box 11474 Palm Desert, Ca. 92255 760-574-6512 Job Name Loma Vista Drawing Location Remote Area Contract Data File Loma Vista Area Calc-1.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 Water Supply Curve Silverado Fire Protection Loma Vista Page Date City Water Supply: Demand: C1 - Static Pressure : 74.03 D1 - Elevation 16.973 C2 - Residual Pressure: 56.19 D2 - System Flow : 31.187 C2 - Residual Flow 32 D2 - System Pressure 47.477 Hose ( Demand ) D3 - System Demand : 31.187 Safety Margin 9.543 150 140 130 P 120 R 110 E 100 S 90 S 80 U 70 R 60 E 50 40 30 20 1 D 10 10 20 30 40 50 60 70 80 90 FLOW (N^1.85) Computer Programs by Hydratec Inc. Revision: 50.54.4 Fittings Used Summary Silverado Fire Protection Page 2 Loma Vista Date Fitting Legend Abbrev. Name '/2 3/4 1 1'/4 1'/2 2 2'/2 3 3'/2 4 5 6 8 10 12 14 16 18 20 24 N* CPVC 90'EII Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O* CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R* CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.54.4 Flow Summary - NFPA Silverado Fire Protection Loma Vista Page 3 Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure W M 74.03 56.19 32.0 57.019 31.19 47.477 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 1 9.19 4.9 7.04 13.0 0.05 256 2 10.0 7.2 3 10.0 9.04 4 16.0 8.85 11 16.0 9.01 5 16.0 9.36 6 16.0 9.66 13 10.0 12.53 7 11.0 15.44 TOR 11.0 25.33 DOM 4.08 28.61 5.0 BOR 1.0 30.48 8 -30.0 47.41 W M -30.0 47.48 9 9.19 4.9 7.24 13.19 0.05 256 14 10.0 7.07 10 16.0 8.83 15 16.0 9.36 12 16.0 9.8 Computer Programs by Hydratec Inc. Revision: 50.54.4 Final Calculations : Hazen -Williams Silverado Fire Protection Page 4 Loma Vista Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 1 9.19 4.90 13.00 1 N 7.0 9.730 150 7.040 to 7.000 -0.351 2 10 13.0 1.101 16.730 0.0307 0.513 Vel = 4.38 2 10 13.19 1 R 1.0 10.440 150 7.202 to 0 5.0 6.000 0.0 3 10 26.19 1.101 16.440 0.1120 1.842 Vel = 8.83 3 10 -13.52 1 30 15.0 54.130 150 9.044 to 6R 6.0 28.000 -2.599 4 16 12.67 1.101 N 7.0 82.130 0.0292 2.401 Vel = 4.27 4 16 1.57 1 4.490 150 8.846 to 0.0 11 16 14.24 1.101 4.490 0.0361 0.162 Vel = 4.80 11 16 -4.60 1 R 1.0 14.000 150 9.008 to 0 5.0 6.000 0.0 5 16 9.64 1.101 20.000 0.0176 0.353 Vel = 3.25 5 16 0.73 1 R 1.0 14.000 150 9.361 to 1.000 0.0 6 16 10.37 1.101 15.000 0.0202 0.303 Vel = 3.49 6 16 -4.43 1 2N 14.0 18.080 150 9.664 to 0 5.0 19.000 2.599 13 10 5.94 1.101 37.080 0.0072 0.267 Vel = 2.00 13 10 4.61 1 5R 5.0 92.600 150 12.530 to 4N 28.0 68.000 -0.433 7 11 10.55 1.101 70 35.0 160.600 0.0208 3.345 Vel = 3.56 7 11 15.64 1 3R 3.0 46.240 150 15.442 to 2N 14.0 42.000 0.0 TOR 11 26.19 1.101 50 25.0 88.240 0.1120 9.886 Vel = 8.83 TOR 11 0.0 1.25 R 1.0 6.920 150 25.328 to 1.000 2.997 DOM 4.08 26.19 1.394 7.920 0.0355 0.281 Vel = 5.51 DOM 4.08 + 5.00 5.00 1.25 N 8.0 3.080 150 28.606 to 8.000 1.334 BOR 1 31.19 1.394 11.080 0.0490 0.543 Vel = 6.56 BOR 1 0.0 2 5N 55.0 361.410 150 30.483 to 55.000 13.426 8 -30 31.19 2.003 416.410 0.0084 3.496 Vel = 3.18 8 -30 0.0 1 0.460 150 47.405 to 0.0 W M -30 31.19 1.101 0.460 0.1565 0.072 Vel = 10.51 0.0 WM 31.19 47.477 K Factor = 4.53 9 9.19 4.90 13.19 1 0 5.0 0.810 150 7.242 to 5.000 -0.351 14 10 13.19 1.101 5.810 0.0315 0.183 Vel = 4.44 14 10 0.0 1 R 1.0 3.080 150 7.074 to 1.000 0.0 2 10 13.19 1.101 4.080 0.0314 0.128 Vel = 4.44 0.0 Computer Programs by Hydratec Inc. Revision: 50.54.4 Final Calculations: Hazen -Williams Silverado Fire Protection Loma Vista Page 5 Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 2 13.19 7.202 K Factor = 4.91 3 10 13.52 1 3R 3.0 36.320 150 9.044 to 0 5.0 36.000 -2.599 10 16 13.52 1.101 4N 28.0 72.320 0.0330 2.386 Vel = 4.56 10 16 -1.57 1 R 1.0 14.000 150 8.831 to 0 5.0 6.000 0.0 15 16 11.95 1.101 20.000 0.0262 0.524 Vel = 4.03 15 16 -0.73 1 0 5.0 14.000 150 9.355 to 5.000 0.0 12 16 11.22 1.101 19.000 0.0234 0.444 Vel = 3.78 12 16 4.42 1 2N 14.0 58.560 150 9.799 to 0 5.0 22.000 2.166 7 11 15.64 1.101 3R 3.0 80.560 0.0432 3.477 Vel = 5.27 0.0 7 15.64 15.442 K Factor = 3.98 10 16 1.57 1 3R 3.0 20.930 150 8.831 to 3.000 0.0 4 16 1.57 1.101 23.930 0.0006 0.015 Vel = 0.53 0.0 4 1.57 8.846 K Factor = 0.53 11 16 4.60 1 4R 4.0 103.360 150 9.008 to 9N 63.0 102.000 2.599 13 10 4.6 1.101 70 35.0 205.360 0.0045 0.923 Vel = 1.55 0.0 13 4.60 12.530 K Factor = 1.30 15 16 0.73 1 20 10.0 25.410 150 9.355 to 2R 2.0 12.000 0.0 5 16 0.73 1.101 37.410 0.0002 0.006 Vel = 0.25 0.0 5 0.73 9.361 K Factor = 0.24 6 16 4.42 1 0 5.0 25.420 150 9.664 to 2R 2.0 7.000 0.0 12 16 4.42 1.101 32.420 0.0042 0.135 Vel = 1.49 0.0 12 4.42 9.799 K Factor = 1.41 Computer Programs by Hydratec Inc. Revision: 50.54.4 Page 1 of 5 N4 I KJ® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION Viking Freedom° Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass -bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler's efficient use of available water supplies for the hydraulically designed fire -protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre -assembled with a threaded adapter for installation with a low -profile small -diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push -on", "thread -off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2" (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS c 4L us UL Listed (C-UL-US-EU): Category VKKW EO Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. WARNING: Cancer and Reproductive Harm- www.P65Warnings.ca.gov 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) Glass -bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-051000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 or Stainless Steel UNS-S30400 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Freedom° Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately: Sprinkler: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 200 °F (93 °C) = E For example, sprinkler VK494 with a Brass finish and a 200 °F (93 °C) temperature rating = Part No. 20759AE. Standard Cover Plates: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16") Stainless Steel Cover Plates (not availble with any finish or paint): Base Part No. 21876 (2-3/4" diameter) or Base Part No. 21875 (3-5/16" diameter). Form No. F_012116 18.10.11 Rev 18.1.P65 Replaces Form No. F_012116 Rev 18.1 (Added P65 Warning.) Page 2 of 5 N4 I Kj® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = M-/B Temperature Suffix: 135 °F/57 °C = A For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 1350417A. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches": A. Heavy Duty Part No. 14047W/B** (available since 2006), or B. Head Cabinet Wrench Part No. 14031't** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) "Requires a'/2' ratchet (not available from Viking). `**Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat -sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly.. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres- sure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Sprinkler Maximum Temperature Rating Cover Large Square Temperature Nominal Ambient of the Cover Plate Cover Plate Cover Plate Bulb Color Classification Temperature Ceiling Assembly Base Part Base Part Base Part Rating' Temperature' (Required)' Number° Number° Number' 13504 or 13642 or Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 °F (57 °C) 15394 Red 218766 218756 13504 or 13642 or Intermediate 200 °F (93 °C) 150 °F (65 °C) 135 °F (57 °C) 15394 Green 218766 218756 Sprinkler Finishes: Brass and ENT Cover Plate Finishes': Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Corrosion Resistant Coatings': ENT Footnotes The sprinkler temperature rating is stamped on the deflector. 2. Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. Maximum ambient temperature for cover assembly is 100 °F (38 °C). 4. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 5. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. 6. Stainless Steel versions are not available with any finishes or paint. Form No. F_012116 18.10.11 Rev 18.1.P65 Page 3 of 5 N4 I Kj® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart Viking VK494, 4.9 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D Sprinkler Base NPT Thread Size Nominal K-Factor Maximum Water Wor- Part Number' SIN king Pressure Inches mm U.S. metric 2 20759 VK494 112 15 4.9 70.6 175 psi (12 bar) Max. Coverage Flow Pressure Listings and Minimum Area 6 GPM (LPM) PSI(bar) Deflector to Installation Approvals',' Spacing Ceiling Type Ft. 155 °F (68 °C), 200 °F (93 °C) Temperature 0 ° coos Ft. X Ft. (m) (m X m) Rated Sprinklers 12 X 12 13 7.0 (3.7 X 3.7) (49.2) (0.48) 14 X 14 13 7.0 (4.3 X 4.3) (49.2) (0.48) Concealed with Cover Plate See Footnotes T9, 10, 8 16 X 16 13 7.0 (4.9 X 4.9) (49.2) (0.48) Refer to Figure 2 Assembly. See Footnote 8. & 11 (2.4) 18 X 18 17 12.0 (5.5 X 5.5) (64.4) (0.83) 20 X 20 20 16.7 (6.1 X6.1) (75.7) (1.15) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price schedule. z. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. I This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. <. Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union. 5. Meets New York City requirements, effective July 1, 2008. 6. For areas of coverage smaller than shown, use the "Flow" and "Pressure' for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow" and "Pressure' used. 7 Cover Temperature Rating is 135 °F (57 °C). Cover Part No. 135041, 136421 (large diameter), or 153941 (square cover plate). s. Other paint colors are available on request with the same listings as the standard finish colors. Stainless Steel cover plates are not available with any finishes or paint. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. e. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 8. 10C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) -stainless Steel Cover plate temperature rating is 135 °F (57 °C). Stainless Steel Cover Part Numbers: 218761 and 218751 (large diameter). Form No. F_012116 18.10.11 Rev 18.1.P65 Page 4 of 5 N I Kj® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) UL Listing Reguirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area" in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT. Always refer to Bulletin Form No. F 080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** Sprinkler Wrench Part No. 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. 2-1/4" (57 mm) diameter opening required in the ceiling. Step 2: 1 1 Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Sprinkler wrench flat Figure 1: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) Sprinkler frame arms Form No. F_012116 18.10.11 Rev 18.1.P65 Page 5 of 5 ® FREEDOM° RESIDENTIAL CONCEALED PENDENT 4 I Ki SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1/2" (15 mm) NPT 2-9116" (65 mm) Maximum 2-1/16" (52 mm) Minimum E t r Ze E 1 N � 2-3/4" (70 mm) or NOTE: Upon sprinkler activation, the deflector descends 3-5/16" (84 mm) to approximately 13116" (21 mm) below the sprinkler body. Figure 2: Sprinkler Dimensions and Cover Installation All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 3: Identification of Custom Paint for Concealed Covers Figure 4: Square Cover Assembly 15394 Form No. F_012116 18.10.11 Rev 18.1.P65 Replaces Form No. F_012116 Rev 18.1 (Added P65 Warning.) CAL FIRE - RIVERSIDE UNIT RIVERSIDE COUNTY FIRE DEPARTMENT OFFICE OF THE FIRE MARSHAL — LA QUINTA CALIFORNIA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org April 26, 2022 Silverado Fire Protection 82417 Priscilla Court Indio, CA 92201 Re: Residential Fire Sprinkler Plan Review — SWENSON RESIDENCE FSS2022-0073 / 77210 LOMA VISTA, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist i6RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD ai�Cv uGKCv THIS CARD IS TO REMAIN ON SITE AT ALL TIMES.—CALIFORNIA— INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 77210 LOMA VISTA PERMIT#: FSS2022-0073 AT ED: 4/26/2022 DESCRIPTION: SWENSON RESIDENCE CONTRACTOR: SILVERADO FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre -pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final IF Deluge/pre-action SPRINKLER U.G. Final EF Thrust block pre -pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final IF Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors' test Hood/duct extinguishing High pile storage High pile rack storage In -rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final IF Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final e F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final e F FIRE ALARM KNOX SYSTEM Rough -wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final F' Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE- 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE -INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131