Loading...
FSS2022-0088ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT NIELSEN'S FIRE PROTECTION, INC.5022 W AVENUE N, SUITE 102-Box E PALMDALE CA 93551 (661)285-3473 JUSTIN@NIELSENSFIRE. COM CONTRACTOR NIELSEN'S FIRE PROTECTION, INC.5022 W AVENUE N, SUITE 102-Box E PALMDALE CA 93551 (661)285-3473 JUSTIN@NIELSENSFIRE. COM OWNER KOHLS DEPARTMENT STORES INC N56 W17000 RIDGEWOOD DR MENOMONEE FALLS WI 92253 (661)285-3473 CONDITIONS Description: ADJUSTING FIRE SPRINKLER FOR TENANT IMPROVEMENTS Type: FIRE SPRINKLER (WEB)Subtype: TENANT IMPROVEMENT Status: FINALED Applied: 3/11/2022 ECON Parcel No: 643080004 Site Address: 78950 HIGHWAY 111 LA QUINTA,CA 92253 Approved: 3/31/2022 KHET Subdivision: PM 25865 Block: Lot: 6 Issued: ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 4/6/2022 KHET Valuation: $5,500.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Wednesday, April 05, 2023 1:49:52 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0088 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 4/6/2022 4/6/2022 APPROVED OVERHEAD HYRO KHET 4/6/2022 4/6/2022 APPROVED FIRE FINAL**KHET 4/6/2022 4/6/2022 APPROVED Tiles in place. Final okay, BCOM TI final still needed. *5-Year Sprinkler Maintenance is required for the building. REVIEWS RETURNED PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS 101-0000-42420 0 $167.00 $167.00 4/1/22 WEB11225 636324857 70 CREDIT 936026 ECON FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS PC 101-0000-42420 0 $333.00 $333.00 4/1/22 WEB11225 636324857 70 CREDIT 936026 ECON Total Paid for FIRE FEES: $500.00 $500.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 4/1/22 WEB11225 636324857 70 CREDIT 936026 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 4/1/22 WEB11225 636324857 70 CREDIT 936026 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$516.00 $516.00 Printed: Wednesday, April 05, 2023 1:49:52 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0088 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 3/11/2022 Etrakit Contractor 1ST SUBMITTAL CUT SHEETS 014.pdf 1 DOC 3/11/2022 Etrakit Contractor 1ST SUBMITTAL PLAN KHOLSLAQUINTA.pdf 1 DOC 3/31/2022 KOHL HETRICK FSS2022-0088 - APPROVED PLANS.pdf FSS2022-0088 - APPROVED PLANS.pdf 1 DOC 3/31/2022 KOHL HETRICK FSS2022-0088 - COA AND JOB CARD.pdf FSS2022-0088 - COA AND JOB CARD.pdf 1 BOND INFORMATION REVIEW TYPE REVIEWER SENT DATE DUE DATE DATE STATUS REMARKS NOTES 1ST FIRE - ETRAKIT (2 WK) KOHL HETRICK 3/11/2022 3/25/2022 3/31/2022 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH – ETRAKIT (1 DAY) PERMIT TECH BUCKET 3/11/2022 3/14/2022 3/14/2022 COMPLETE Printed: Wednesday, April 05, 2023 1:49:52 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0088 CONTINUED TOSYSTEMCONTINUED TOSYSTEMCONTINUED TOSYSTEMCONTINUED TOSYSTEMCONTINUED TOSYSTEMCONTINUED TOSYSTEM(E) (E)(E)(E) (E) (E) (E) (E) (E) (E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)(R)(R)(R)(R)(R)(R)(R)(R)(R)(R)(R)(R)(R)(R)(R)(R)(R)(R)(R)(R)(R)(R)KOHL'S - LA QUINTA - STORE #10677VICINITY MAPHANGER RING3/8" ALL THREAD RODJAM ATR AGAINSTTOP OF PIPEEND OF LINE RESTRAINT (ATR)PIPE- SYMBOL DENOTES END OF LINE RESTRAINT excess of 150 psi. shall not exceed 24 in.* On the end hanger use either "Tolco Surge Clip" Fig.#2 in excess of the maximum pressure, when the maximum bars) pressure for two hours, or at 50 psi (3.4 bars) or tighten down ATR to the top of pipe when rods and* The length of an unsupported armover to a sprinkler pressure to be maintained in the system is in* All new systems including yard piping shall be hydrostatically tested at not less than 200 psi (13.8* Install tamper switches on all control valves and rings are used.* All wiring to be provided by others. provided by others.* Riser nipples/outlets on schedule 10 steel* All armovers to be 1" x 0'-4" unless noted otherwise.* Propriety and central station monitoring to be All welding shall conform to NFPA Standards. piping to be mechanical tees or weld-o-lets, typical.* All pipe 2½" - 4" to be schedule 10 black steel (ASTM-A135) with grooved couplings, Victaulic Fig.#005 grooved rigid couplings, and Fig.#77 flexible couplings (or equal). GENERAL OVERHEAD NOTES* All design and installation shall be in accordance with NFPA 13, 2016 Ed., all relevant building and fire codes, coordinated with fire alarm system. & Local Authority* The existing main floor system is designed @ .20/1500 sq.ft. minimum, with the use of QR-Standard spray sprinkler pendents.* All pipe 1"- 2" to be schedule 40 black steel (ASTM-A135) with cast iron threaded fittings.SCOPE OF WORK:NIELSEN'S FIRE PROTECTION SHALL MODIFY EXISTING SPRINKLERSYSTEM IN AREA OF WORK AS NECESSARY TO PROVIDE NEW LAYOUT ASSHOWN ON THIS DRAWING. REMOVE ALL PIPING, HANGERS ANDSPRINKLERS NOT INTENDED FOR REUSE. ADD SPRINKLERS AND PIPINGAS NECESSARY TO INSTALL SPRINKLER LAYOUT AS SHOWN ON THISDRAWING. COORDINATE WITH OTHER TRADES AND FIELD CONDITIONSTO PREVENT OBSTRUCTIONS AND CONFLICTS WITH SPRINKLER SYSTEM.xDEMO EXISTING PENDENT SPRINKLERS NO LONGER NEEDED INREMODELED AREA. ALL SPRINKLERS REMOVED FROM THE SYSTEMSHALL HAVE EXISTING DROPS REMOVED OR PLUGGED.xRELOCATE SPRINKLERS TO CENTERLINE OF TILE WHERE REQUIRED(3 TOTAL).xRELOCATE SPRINKLERS IN REMODELED ARE FROM THE EXISTINGELEVATION OF 9'-6" TO THE NEW ELEVATION OF 11'-2".xALL RELOCATED SPRINKLERS SHALL BE REPLACED LIKE FOR LIKE.SEE SPRINKLER LEGEND FOR MORE INFORMATION.TENANT IMPROVEMENT - SYMBOL LEGEND- EXISTING SSP- RELOCATED SSP Sprinkler heads in this area to be spaced at a maximum of 130 sq.ft.(E)(R)HEAD CAB'T & WRENCH(ES) PROVIDEDTOTAL COUNT THIS SHEET = FINISHTEMP.ORIFICEMFG.SYMBOLSPRINKLER SCHEDULE & LEGENDK-FACTORSIN#MODEL22QUANTITYHEAD TYPE(6)RELIABLE22CHRM.155°½"5.6RA1414F1FR56NEW QR SEMI-REC. SSPFIRE SPRINKLER PIPING PLAN02' 4' 8'SCALE: IN FEET1/4" = 1'-0"KOHL'S - LA QUINTA - STORE #: 10677KEY MAPKOHL'S - LA QUINTA - STORE #: 10677N.T.S.SAMMY SWG 200 PIPE HANGERSWG 200ALL THREAD RODADJUSTABLE RING HANGERWOOD NAILERAPPROVEDRiverside County Fire DepartmentLa Quinta Office of the Fire MarshalBy:FIRE SAFETY SPECIALIST03/31/2022 8:24:06 AMThe approval of plans and specifications does notpermit the violation, deletion, omission or faultyinstallation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remainaccessible and exposed for inspection purposesuntil approved by the Fire Department.PERMIT # -FSS2022-0088Kohl HetrickReason: I am approving this documentContact Info: 760-409-5109 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F1FR Series Quick Response Glass Bulb Sprinklers Bulletin 014 December 2021Bulletin 014 December 2021 Model F1FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model F1FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model F1FR56 Concealed Sprinkler Types Standard Spray Pendent Model F1FR42, F1FRXLH & F1FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model F1FR40 Sprinkler Types Standard Spray Pendent Model F1FR42, F1FR40, F1FRXLH & F1FR28 Recessed Sprinkler Types Standard Spray Pendent Model F1FR56LL & F1FR42LL Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Con- tent Listing & Approvals The following organizations provide Listings or Approvals for various Model F1FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprinkler. 1. Underwriters Laboratories Inc. and Certified for Cana- da (cULus) in accordance with ANSI/UL199. 2. FM Approvals (FM) 3. Loss Prevention Certification Board (LPCB) 4. VdS Schadenverhütung GmbH (VdS) 5. Underwriters Laboratories Inc. and Underwriters Lab- oratories of Canada Certified for Health Effects to NSF/ ANSI Standard 61 Annex G (ULH) 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) (EC) 7. WaterMark certified. Certificate Number 23347. (WM) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Pendent Conventional Recessed Pendent/F1/F2 Upright Vertical Sidewall Horizontal Sidewall Recessed Horizontal Sidewall Recessed Pendent/FP Concealed Pendent XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 XLH Recessed Pendent FP Product Description Reliable Model F1FR series sprinklers are quick-response automatic sprinklers with a glass bulb thermal element. Model F1FR series sprinklers are Standard Spray sprinklers, with the exception of the Model F1FR56 Conventional sprinkler which is an Old-style/Conventional sprinkler. The Model F1FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same tem- perature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufac- tured glass capsule. This glass bulb is specially constructed to provide fast thermal response.Jan 2022 NOTE: Please see website for updated versions of K2.8, K4.0, K4.2, and XLH Sprinklers 2. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distribute the discharging water. Model F1FR Series sprinklers provide a wide range of options where quick-response, glass bulb sprinklers are used:• Pendent, recessed pendent, upright, horizontal side - wall, and vertical sidewall deflectors• K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric)• Flush, recessed, and concealed installations See the Design and Installation Information table in this Bul- letin for information on the approvals and availability of specific Model F1FR series sprinkler configurations. Model F1FR Recessed Pendent and Recessed Horizontal Sidewall sprinklers are required to be used with Reliable Model F1, F2, or FP recessed escutcheons. See the Recessed Es - cutcheon Data table in this Bulletin for listing and approval infor- mation with each specific Model F1FR series sprinkler. Model F1 and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2- inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cover plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and Installation Infor- mation and Listed and Approved Temperature Ratings tables in this Bulletin for further information on approved cover plate options. Application Model F1FR Series sprinklers are intended for use in ac- cordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Having Juris- diction. Care must be exercised that the k-factor, tempera- ture rating, deflector style, and sprinkler type are in accor- dance with the requirements of the applicable design and installation standards. In addition, Model F1FR Series sprin- klers must be used in accordance with their listings and ap- provals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or protec- tive caps to minimize bulb damage during shipping, handling and installation. Reliable sprinkler installation wrenches are designed to install sprinklers with bulb protectors in place. Re - move the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protec- tor before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Model F1FR Series sprinklers must be installed with the Reli- able sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model F1FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the specific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model F1FR Series Recessed sprinkler. The use of any other recessed escutcheon will void all approvals and negate all warranties. Concealed Sprinklers Model F1FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers have a facto- ry-installed Model CCP cup. A protective cap is installed at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread- off cover plate assembly. The cover plate and sprinkler cup as - semblies are joined using a cover plate skirt with flexible tabs for threaded engagement. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model W4 wrench is used to engage the sprinkler wrenching sur- faces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent dam- age to the sprinkler. Do not wrench any other part of the sprinkler/ cup assembly. Installation is completed by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/ cup assembly other than the Reliable Model CCP with Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not spe - cifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals.Jan 2022 NOTE: Please see website for updated versions of K2.8, K4.0, K4.2, and XLH Sprinklers 3. Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector/ Orientation Nominal Sprinkler Height Installation Wrench SIN Listings and Approvals Approval Notes US Metric inches mm inches mm F1FR28 2.8 40 3/8 10 Pendent 2.25 57 W2 RA1411 cULus 2 Recessed Pendent 2.25 57 W4 RA1411 cULus 2 Upright 2.25 57 W2 RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA1418 VdS Recessed Pendent 2.25 57 W4 RA1418 VdS F1FR42 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 W4 RA1413 cULus 2 Upright 2.25 57 W2 RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 W4 RA1410 cULus, ULH F1FRXLH (F1FR42 with Pintle) 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 W4 RA1413 cULus 2 Upright 2.25 57 W2 RA1423 cULus 1,2 F1FR56 5.6 80 1/2 15 Pendent 2.25 57 W2 RA1414 cULus, FM, LPCB, VdS, EC, WM 1,2,3,4 Recessed Pendent 2.25 57 W4 RA1414 cULus, FM, LPCB, VdS, EC, WM 1,2,3,4 Concealed Pendent 2.25 57 W4 RA1414 cULus,VdS,EC, WM 5,6 Upright 2.25 57 W2 RA1425 cULus, FM, LPCB, VdS, EC, WM 1,2,3,4 "Conventional (Pendent or Upright)"2.25 57 W2 RA1475 LPCB, VdS, EC, WM 4 F1FR56LL 5.6 80 1/2 15 Pendent 2.25 57 W2 RA1415 cULus, ULH 1 Recessed Pendent 2.25 57 W4 RA1415 cULus, ULH Concealed Pendent 2.25 57 W4 RA1415 cULus, ULH 6 F1FR56 5.6 80 1/2 15 Horizontal Sidewall 2.63 67 W2 RA1435 cULus, FM 1,2,3,7 Recessed Horizontal Sidewall 2.63 67 W4 RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 15 Vertical Sidewall (Pen- dent or Upright)2.25 57 W2 RA1485 cULus, FM, LPCB 1,2,3,9 (1) cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2) cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (3) Available with FM approved Polyester coating in black or white. (4) Available with LPCB and VdS approved Polyester coating. (5) VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprinklers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. (6) Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. (7) cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches (102mm to 305mm). FM Approval of the F1FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (8) cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (9) The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar)Jan 2022 NOTE: Please see website for updated versions of K2.8, K4.0, K4.2, and XLH Sprinklers 4. Listed and Approved Temperature Ratings Model Deflector/ Orientation Ordinary Temp. Classification 100°F (38°C) Max. Ambient Temp. Intermediate Temp. Classification 150°F (65°C) Max. Ambient Temp. High Temp. Classification 225°F (107°C) Max. Ambient Temp. 135°F (57°C) Temp. Rating 155°F (68°C) Temp. Rating 175°F (79°C) Temp. Rating 200°F (93°C) Temp. Rating 286°F (141°C) Temp. Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb F1FR28 Pendent cULus Recessed Pendent cULus Upright cULus F1FR40 Pendent VdS Recessed Pendent VdS F1FR42 Pendent cULus Recessed Pendent cULus Upright cULus F1FR42LL Pendent cULus, ULH Recessed Pendent cULus, ULH F1FRXLH Pendent cULus Recessed Pendent cULus Upright cULus F1FR56 Pendent cULus, FM, LPCB, VdS, EC, WM Recessed Pendent cULus, FM, LPCB, VdS, EC, WM Concealed Pendent*cULus, WM cULus,VdS,EC, WM cULus, WM Upright cULus, FM, LPCB, VdS, EC, WM “Conventional (Pendent or Upright)”LPCB, VdS, EC, WM F1FR56LL Pendent cULus, ULH Recessed Pendent cULus, ULH Concealed Pendent*cULus, ULH F1FR56 Horizontal Sidewall cULus, FM Recessed Horizontal Sidewall cULus, FM F1FR56 Vertical Sidewall (Pen- dent or Upright)cULus, FM, LPCB * Model F1FR56 Concealed Pendent and F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For In- termediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Model Deflector/ Orientation Listed and Approved Recessed Escutcheons SIN Model F1 (Fig. 1 & 3) 3/4-inch (19mm) adjustment Model F2 (Fig. 1 & 3) 1/2-inch (12.7mm) adjustment Model FP (Fig. 2) 1/2-inch (12.7mm) adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, EC, WM cULus, FM, LPCB, VdS, EC, WM cULus, VdS, EC, WM RA1414 F1FR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435Jan 2022 NOTE: Please see website for updated versions of K2.8, K4.0, K4.2, and XLH Sprinklers 5. Fig. 1 Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon Fig. 2 Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model FP escutcheonJan 2022 NOTE: Please see website for updated versions of K2.8, K4.0, K4.2, and XLH Sprinklers 6. Fig. 3 Model F1FR56 Recessed Horizontal Sidewall sprinkler with Model F1 or F2 escutcheon Fig. 4 Model F1FR56/F1FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model CCP cover plateJan 2022 NOTE: Please see website for updated versions of K2.8, K4.0, K4.2, and XLH Sprinklers 7. Fig. 5 - Model F1FR56/F1FR56LL Concealed Pendent sprinkler with low profile 5/16- inch (8.0mm) adjustment - Model CCP cover plate Maintenance The Model F1FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Finishes (1) (2) Standard Finishes Sprinkler Escutcheon Cover plate Bronze Brass Chrome Chrome Chrome White White Polyester (3)(6)(7)White Special Application Finishes Sprinkler Escutcheon Cover plate Electroless Nickel PTFE(3)(4) Electroless Nickel PTFE Bright Brass Black Polyester (3)(6)(7)Bright Brass Black Bright Brass (5)Black Off White Off White(6)(7) Off White Satin Chrome Satin Chrome Satin Chrome (1) Other finishes and colors may be available on special order. Consult the factory for details. (2) Paint or any other coating applied over the factory finish will void all approvals and warranties. (3) cULus Listed as Corrosion Resistant. (4) FM Approved as Corrosion Resistant for SIN RA1414, RA1425, RA1435, and RA1485. (5) 200*F (93*C) maximum temperature rated sprinkler only. (6) VdS Approved for RA1425, RA1414, RA1418, and RA1475. (7) LPCB Approved for RA1425, RA1414, and RA1475. Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Deflector:CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup:CDA Alloy 651 or 693 Washer:Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb:Glass Ordering Information Specify: 1. Sprinkler Model: [F1FR28][F1FR40][F1FR42] [F1FR42LL][F1FRXLH][F1FR56][F1FR56LL] 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent][Upright][Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] 3. Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] 4. Sprinkler Temperature Rating: [135°F (57°C)][155°F (68°C)][175°F (79°C)][200°F (93°C)][286°F (141°C)] 5. Sprinkler Finish 6. Escutcheon Model: [F1][F2][FP] 7. Escutcheon Finish (where applicable) 8. Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.0mm) adjustment] 9. Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] 10. Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprin- klers and escutcheons are packaged separately. Jan 2022 NOTE: Please see website for updated versions of K2.8, K4.0, K4.2, and XLH Sprinklers Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 12/21 P/N 9999970300 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 100 years. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many pre - cision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection Jan 2022 NOTE: Please see website for updated versions of K2.8, K4.0, K4.2, and XLH Sprinklers OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org March 31, 2022 Nielsen’s Fire Protection, INC 5022 W Avenue N #102-E Palmdale, CA 93551 Re: TI Fire Sprinkler Plan Review – KOHL’S - SEPHORA 78950 HIGHWAY 111, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. The following inspections/tests are required to be witnessed by the Office of the Fire Marshal staff: 1) Overhead Rough: All installed/relocated piping must be visible. 2) Final inspection: All trim is in place, 5-Year certification is current. New/added heads shall be included in the spare head box compliment. *Water-flow signal test may be performed during the Final Inspection. All persons performing work on the automatic fire sprinkler system shall be Certified Sprinkler Fitters or Registered with the State Fire Marshal for Apprentice or Trainee classification. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 78950 HIGHWAY 111 PERMIT#: FSS2022-0088 DATE ISSUED: 3/31/2022 DESCRIPTION: KOHL’S - SEPHORA CONTRACTOR: NIELSEN’S FIRE PROTECTION INC. HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.