Loading...
FSS2022-0089ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT LEEMEN FIRE PROTECTION 17845 STAGG ST RESEDA CA 91335 (818)970-3312 SCOTTPLUS123@GMAI L.COM CONTRACTOR LEEMEN FIRE PROTECTION 17845 STAGG ST RESEDA CA 91335 (818)970-3312 SCOTTPLUS123@GMAI L.COM OWNER 111 LA QUINTA CENTER PARTNER 78060 CALLE ESTADO LA QUINTA CA 92253 (818)970-3312 CONDITIONS Description: MARU / ADD AND RELOCATE SPRINKLER HEADS Type: FIRE SPRINKLER (WEB)Subtype: TENANT IMPROVEMENT Status: FINALED Applied: 3/14/2022 ECON Parcel No: 643220014 Site Address: 78702 HIGHWAY 111 LA QUINTA,CA 92253 Approved: 3/31/2022 KHET Subdivision: PM 25865 Block: Lot: 16 Issued: ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 5/3/2022 KHET Valuation: $5,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Wednesday, April 05, 2023 1:52:16 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0089 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 4/12/2022 4/12/2022 APPROVED OVERHEAD HYRO KHET 4/12/2022 4/12/2022 APPROVED FIRE FINAL**KHET 5/3/2022 5/3/2022 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS 101-0000-42420 0 $167.00 $167.00 4/1/22 WEB11228 636330742 34 CREDIT 1077869 ECON FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS PC 101-0000-42420 0 $83.00 $83.00 4/1/22 WEB11228 636330742 34 CREDIT 1077869 ECON Total Paid for FIRE FEES: $250.00 $250.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 4/1/22 WEB11228 636330742 34 CREDIT 1077869 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 4/1/22 WEB11228 636330742 34 CREDIT 1077869 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$266.00 $266.00 Printed: Wednesday, April 05, 2023 1:52:16 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0089 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 3/14/2022 Etrakit Contractor 1ST SUBMITTAL FIRE SPRINKLER PLAN Maru BBQ Fire Sprinkler Plan.pdf 1 DOC 3/14/2022 Etrakit Contractor 1ST SUBMITTAL SPECS Maru BBQ Sprinkler Cut Sheet.pdf 1 DOC 3/31/2022 KOHL HETRICK FSS2022-0089 - APPROVED PLANS.pdf FSS2022-0089 - APPROVED PLANS.pdf 1 DOC 3/31/2022 KOHL HETRICK FSS2022-0089 - COA AND JOB CARD.pdf FSS2022-0089 - COA AND JOB CARD.pdf 1 BOND INFORMATION 1ST FIRE - ETRAKIT (2 WK) KOHL HETRICK 3/14/2022 3/26/2022 3/31/2022 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH – ETRAKIT (1 DAY) PERMIT TECH BUCKET 3/14/2022 3/15/2022 3/15/2022 COMPLETE Printed: Wednesday, April 05, 2023 1:52:16 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0089 APPROVEDRiverside County Fire DepartmentLa Quinta Office of the Fire MarshalBy:FIRE SAFETY SPECIALIST03/31/2022 11:13:58 AMThe approval of plans and specifications does notpermit the violation, deletion, omission or faultyinstallation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remainaccessible and exposed for inspection purposesuntil approved by the Fire Department.PERMIT # -FSS2022-0089Kohl HetrickReason: I am approving this documentContact Info: 760-409-5109 General Description The Series TY-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers described in this data sheet are standard response - standard cover- age, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refin- eries, chemical plants, etc. The recessed version of the Series TY-B Pendent Sprinkler, where appli- cable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 10 (1/2 inchNPT)orStyle40(3/4 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjust- ment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pen- dentposition.Theadjustmentprovided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical towhich the sprinklerswillbe exposed. An intermediate level version of the Series TY-B Pendent Sprinkler can be obtained by utilizing the Series TY-B Pendent Sprinkler in combination with the Model S2 Shield. WARNINGS The Series TY-B Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the integrity of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Model/Sprinkler Identification Numbers TY1151 - Upright 2.8K, 1/2"NPT TY1251 - Pendent 2.8K, 1/2"NPT TY3151 - Upright 5.6K, 1/2"NPT TY3251 - Pendent 5.6K, 1/2"NPT TY4151 - Upright 8.0K, 3/4"NPT TY4251 - Pendent 8.0K, 3/4"NPT TY4851 - Upright 8.0K, 1/2"NPT TY4951 - Pendent 8.0K, 1/2"NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (RefertoTable Aforcomplete approval information including corrosion resis- tant status.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=2.8GPM/psi1/2 (40,3 LPM/bar 1/2) K=5.6GPM/psi1/2 (80,6 LPM/bar 1/2) K=8.0GPM/psi1/2 (115,2 LPM/bar 1/2) Temperature Ratings RefertoTableA Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............ Bronze Button ........ Brass/Copper SealingAssembly.......... . . . . . . Beryllium Nickel w/Teflon† Bulb ..............Glass Compression Screw . . . . . Bronze Deflector...........Copper Bushing (K=2.8) . . . . . . . Bronze † DuPont Registered Trademark Series TY-B — 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage Page 1 of 8 TFP151JANUARY, 2003 Technical Services:Tel: (800) 381-9312 / Fax: (800) 791-5500 Customer Service/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Page2of8 TFP151 FIGURE 1 STANDARD RESPONSE SERIES TY-B UPRIGHT (TY1151) AND PENDENT (TY1251) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT 1 - Frame 2-Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector 7 - Bushing *Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 STANDARD RESPONSE SERIES TY-B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT 1 - Frame 2-Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector *Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. 2 4 5 6 PENDENT CROSS SECTION (55,6 mm) 2-3/16" (38,1 mm) 1-1/2" PLATE SEATING ESCUTCHEON 7/16" (11,1 mm) NOMINAL MAKE-IN FLATS WRENCH SURFACE 1 3 NPT 1/2" RECESSED PENDENT UPRIGHT 2-7/8" (73,0 mm) DIA. (11,1 mm) NOMINAL MAKE-IN 7/16" RECESSED STYLE 10 ESCUTCHEON (55,6 mm) 2-3/16" 1/2" NPT DEFLECTOR SSU SSP DEFLECTOR ** ** * * * 2 4 5 6 7 3 PLATE SEATING ESCUTCHEON (57,2 mm) 2-1/4" WRENCH (39,7 mm) 1-9/16" FLATS 7/16"(11,1 mm) NOMINAL MAKE-INSURFACENPT 1/2" 2-3/16" (55,6 mm) SSU DEFLECTOR DEFLECTOR SSP 1 SECTIONPENDENT UPRIGHT CROSS *** * TFP151 Page 3 of 8 PLATE SEATING ESCUTCHEON (57,2 mm) 2-1/4" WRENCH (39,7 mm) 1-9/16" FLATS 7/16"(11,1 mm) NOMINAL MAKE-INSURFACENPT 1/2" 2-3/16" (55,6 mm) SSU DEFLECTOR DEFLECTOR SSP SECTIONPENDENT UPRIGHT CROSS 3 1 2 5 4 6 7 *** * * FIGURE 4 STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT 1 - Frame 2-Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector *Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. 2 4 5 6 PENDENT CROSS SECTION (58,7 mm) 2-5/16" (39,7 mm) 1-9/16" PLATE SEATING ESCUTCHEON 1/2" (12,7 mm) NOMINAL MAKE-INSURFACE 1 3 NPT 3/4" RECESSED PENDENT UPRIGHT (12,7 mm) NOMINAL MAKE-IN 1/2" RECESSED STYLE 40 ESCUTCHEON (57,2 mm) 2-1/4" 3/4" NPT DEFLECTOR SSU SSP DEFLECTOR 7 FLATS WRENCH 2-7/8" (73,0 mm) DIA. ** *** * * FIGURE 3 STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4151) AND PENDENT (TY4251) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT 1-Frame 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector 7 - Ejection Spring *Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. Page4of8 TFP151 TYPE TEMP.BULB LIQUID NATURAL BRASS CHROME PLATED WHITE*** POLYESTER 155°F/68°C 175°F/79°C 200°F/93°C SPRINKLER FINISH (See Note 7) RECESSED PENDENT (TY3251)* Figure 4 135°F/57°C Orange Red Yellow Green 1, 2, 3, 5 NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Approved by the Loss Prevention Certification Board (LPCB). 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). 7. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** 150°F/66°C Maximum Ceiling Temperature. *** Frame and deflector only. Listings and approvals apply to all colors (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 1, 2, 5 WAX OVER LEAD COATED LEAD COATED WAX COATED N/A 1, 2 N/A 5.6 1/2" NPT PENDENT (TY3251) and UPRIGHT (TY3151) 135°F/57°C Orange 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 360°F/182°C Mauve 1, 2, 3 RECESSED PENDENT (TY4251)* Figure 5 135°F/57°C 1, 2, 3, 5 Orange 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green N/A 8.0 3/4" NPT PENDENT (TY4251) and UPRIGHT (TY4151) 135°F/57°C 155°F/68°C 175°F/79°C 200°F/93°C 286°F/141°C 360°F/182°C Mauve Blue Green Yellow Red Orange 1, 2, 3, 4, 5, 6 1, 2, 5 1, 2, 3, 5 1, 2, 5 1**,2**, 3**, 5**1**, 2**, 5** N/A 8.0 1/2" NPT PENDENT (TY4951) and UPRIGHT (TY4851) 135°F/57°C 155°F/68°C 175°F/79°C 200°F/93°C 286°F/141°C 360°F/182°C Mauve Blue Green Yellow Red Orange 1, 2, 3, 5 N/A K 135°F/57°C 155°F/68°C 175°F/79°C 200°F/93°C 286°F/141°C 360°F/182°C Orange Red Yellow Green Blue Mauve 1, 2, 3, 4, 5, 6 1, 2, 3, 5 1, 2, 3, 5 1, 2, 3, 5 1**,2**, 3**, 5**1**, 2**, 3**, 5** N/A PENDENT (TY1251) and UPRIGHT (TY1151) 2.8 1/2" NPT Operation The glass Bulb contains a fluid which expands when exposed to heat.When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-B Pendent and Upright Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM’s Loss Prevention Data Sheets). Only the Style 10 or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. TFP151 Page 5 of 8 FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT (57,2 mm) 2-1/4" DIA. (73,0 mm) 2-7/8" DIA. SPRINKLER MOUNTING CLOSURE SURFACE FACE OF FITTING (15,9±6,4 mm) 5/8±1/4" (3,2 mm) 3/4" (19,1 mm) 1-1/4" (31,8 mm) PLATE MOUNTING 1/8" 1/4" (6,4 mm) 3/4" (19,1 mm) SERIES TY-B FIGURE 7 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 8 W-TYPE 7 RECESSED SPRINKLER WRENCH RECESS WRENCH WITH SPRINKLER ENGAGEMENT IN TO ENSURE WRENCHING AREA PUSH WRENCH FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) MOUNTING SPRINKLER CLOSURE SURFACE FITTING FACE OF (15,9±6,4 mm) 5/8±1/4" MOUNTING PLATE 1-5/16" (33,3 mm) 13/16" (20,6 mm) (3,2 mm) 1/8" 3/4" (19,1 mm) 1/4" (6,4 mm) SERIES TY-B Installation The Series TY-B Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 360°F/182°C temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-B Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1.Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2.With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3.Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 7), except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figures1,2,3,and4theW-Type7 Sprinkler Wrench or the adjustable Crescent wrench, as applicable is to be applied to the wrench flats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler,loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench flatsandframearmsmustbein- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coating ap- plied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. If attempts to retouch the wax coating with complete coverage are unsuc- cessful, additional wax can be ordered in the form of a wax stick (the end of which is color coded). Only the correct color coded wax is to be used, and retouching of wrench flats and frame arms is only permitted at the time of initial sprinkler installation. With the steel rod heated as previously de- scribed, touch the rod to the area re- quiring additional wax with the rod an- gled downward, and then touch the wax stick to the rod approximately one-half inch away from the area re- quiring retouching. The wax will melt and run down onto the sprinkler. The Series TY-B Recessed Pendent Sprinklers must be installed in ac- cordance with the following instruc- tions. Step A.After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 8).With reference to Figure 3 or 4, the W-Type 7 Recessed Sprinkler Wrench is to be appliedto the sprinkler wrench flats. Step C.After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10 or 40 Clo- sure over the Series TY-B Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- tact with the ceiling. Page6of8 TFP151 Care and Maintenance The Series TY-B Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that itcontrols,permissiontoshutdownthe affectedfireprotectionsystem mustbe obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed.Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturershouldbecontactedrelativeto any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products’ sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer’s representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES,ANDINNOEVENT SHALL TYCO FIRE PRODUCTS’ LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHERWARRANTIESEXPRESSOR IMPLIED,INCLUDINGWARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. TFP151 Page 7 of 8 Ordering Procedure When placingan order,indicate the full product name. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Stand- ard Response, (specify K-factor), (specify temperature rating), Series TY-B (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table B). Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 1/2" (15 mm) Style 10 Chrome Plated . . . . . . . . . P/N 56-701-9-010 1/2" (15 mm) Style 10 White Color Coated . . . . . . . . . . . . . . . P/N 56-701-4-010 1/2" (15 mm) Style 10 Brass Plated. . . . . . . . . . . P/N 56-701-2-010 3/4" (20 mm) Style 40 Chrome Plated . . . . . . . . . P/N 56-700-9-010 3/4" (20 mm) Style 40 White Color Coated . . . . . . . . . . . . . . . P/N 56-700-4-010 3/4" (20 mm) Style 40 Brass Plated. . . . . . . . . . . P/N 56-700-2-010 Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. Wax Sticks: (for retouching wrench damaged wax coating) Specify: (Specify color) color coded Wax Stick for retouching (specify tem- perature rating) temperature rated Se- ries TY-B Sprinklers, P/N (specify). Black for 135°F . . . . . . . . . . . . P/N 56-065-1-135 Red for 155°F . . . . . . . . . . . . . P/N 56-065-1-155 Yellow for 175°F . . . . . . . . .P/N 56-065-1-175 Blue for 200°F and 286°F . . . . . . . . . . . . . . . . . P/N 56-065-1-286 NOTES Each wax stick is suitable for retouch- ing up to twenty-five sprinklers. The wax used for 286°F sprinklers is the same as for 200°F sprinklers, and, therefore,the286°Fsprinklerislimited to the samemaximumceilingtempera- ture as the 200°F sprinkler (i.e., 150°F). Page8of8 TFP151 TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 P/N 57 — XXX — X — XXX 360°F/182°C 155°F/68°C 360 155 TEMPERATURE RATING 135°F/57°C135 8.0K UPRIGHT (1/2"NPT) 561 560 1 SPRINKLER TABLE B PART NUMBER SELECTION SERIES TY-B PENDENT AND UPRIGHT SPRINKLERS 8.0K PENDENT (1/2"NPT) 175°F/79°C 286 200°F/93°C200 286°F/141°C 175WHITE POLYESTER NATURAL BRASS 9 4 MODEL/SIN CHROME PLATED 7 LEAD COATED 6 WAX COATED 286°F/141°C MAX. 8 WAX OVER LEAD 286°F/141°C MAX. 590 8.0K UPRIGHT (3/4"NPT) 591 8.0K PENDENT (3/4"NPT) 530 2.8K UPRIGHT (1/2"NPT) 531 2.8K PENDENT (1/2"NPT) TY1151 TY1251 TY4151 TY4251 TY4851 TY4951 570 571 5.6K UPRIGHT (1/2"NPT) 5.6K PENDENT (1/2"NPT) TY3151 TY3251 Office/Manufacturing Facility •1375 Sampson Ave. •Corona, CA 92879 •Ph: 951.737.5599 •Fax: 951.737.0330 Customer Service •800.786.5266 www.tolco.com 90 wwwwww..ttoollccoo..ccoomm Revision 5/24/2001 ™ ® a brand of Fig. 200 - “Trimline” Adjustable Band Hanger Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. •(21/2" thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters’ Laboratories listed (1/2" thru 8") in the USA (UL)and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Mil. Galvanized. For Stainless Steel materi- als, order TOLCO™ Fig. 200WON. Order By — Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric ABLoad Lbs. Length 1/2 3/8 8mm or 10mm 3 1/8 25/8 400 11 3/4 3/8 8mm or 10mm 3 1/8 21/2 400 11 1 3/8 8mm or 10mm 3 3/8 25/8 400 12 11/4 3/8 8mm or 10mm 3 3/4 27/8 400 13 11/2 3/8 8mm or 10mm 3 7/8 27/8 400 14 2 3/8 8mm or 10mm 4 1/2 3 400 15 21/2 3/8 10mm 5 5/8 41/8 600 27 3 3/8 10mm 5 7/8 4 600 29 31/2 3/8 10mm 7 3/8 51/4 600 34 4 3/8 10mm 7 3/8 5 1000 35 5 1/2 12mm 9 1/8 61/4 1250 66 6 1/2 12mm 10 1/8 63/4 1250 73 8 1/2 12mm 13 1/8 83/4 1250 136 S3 - 3 Comparison to L.W.T. PipesComparison to Schedule 40 Specifications & Approvals Dyna-Thread® Full Line Sch-40 Replacement Dyna-Thread® offers the life expectancy of Sch-40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. • Dyna-Thread’s inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. • Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. • The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. • The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. • The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. • More wall thickness at the thread (CRR=1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. • Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. • Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. • Dyna-Thread is safer to weld on. • Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be “hot-dip” galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specifications NPS Nominal I.D. Wt. Wt. (H2O Filled) Pcs/ Wt/Lift (21')Wt/Lift (24')Wt/Lift (25') In; mm In; mm Lbs/Ft; Kg/m Lbs/Ft; Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.080 1.330 1.75 70 1955 2234 2327 25 27.4 2.0 2.60 70 887 1013 1056 11⁄4" 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 1081 11⁄2" 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 1143 2" 2.104 3.050 4.57 30 1921 2196 2287 50 53.4 4.5 6.80 30 871 996 1037 • With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000” in diameter is coated with our new Antibacterial Formula, “ABF”. In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. FM Listed Approved Listed 16100 S. Lathrop • Harvey, IL 60426 11350 Norcom Rd. • Philadelphia, PA 19154 2525 N. 27 th Ave. • Phoenix, AZ 85009 Customer Service: (800) 882-5543 Fax 708-339-1806 5 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETENot less than 2” nominal width (1-1/2”) up to 3-1/2” pipe; not less than 3” (2-1/2”) nominal width 4” & 5” pipe Minimum 2-1/2” from bottom for branch lines. Minimum 3” from bot- tom for main lines. Exception: This requirement shall not apply to 2” or thicker nailing strips resting on top of steel beams. Floor Joist Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) Box Qty Case Qty HORIZONTAL MOUNT 1/4"8019957 SWG 200 1/4 x 2"1725 (Fir)25 125 3/8"8020957 SWG 10 1/4 x 1"622 (Fir)300 25 125 3/8"8021957 SWG 20 1/4 x 2"1725 (Fir)1050 25 125 3/8"8073925 SWG 20-SS 1/4 x 2"1725 (Fir)850 25 125 3/8"*8022925 SWG 25-380 3/8 x 2-1/2"2249 (Fir)1500 25 125 3/8"8023925 SWG 30 1/4 x 3"1884 (Fir)25 125#14 SW Red Nut Driver Part # 8114910 • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation costs. • Manufactured in the U.S.A. Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thickness Box Qty Case Qty SWIVEL MOUNT 3/8"8139957 SH-GST 20 1/4 x 2"1257 (Fir)1050 1475 25 125 3/8"*8269957 SH-GST/CST 20 5/16 x 1-3/4” 1903 Dim. Lumber 1406 @ 45°off vertical Dim. Lumber 1500 850 @ 45°25 125 1/2”8303957 SH-GST/CST 2.0 5/16 x 1-3/4” 903 Dim. Lumber 1406 @ 45°off vertical Dim. Lumber 25 125 #14 Black Nut DriverPart # 8113910 • Eliminates distortion of threaded rod. • Accommodates up to 3 ½” x 12 pitch roof. • Allows 17° deflection from vertical. • Saves time from traditional methods. • Reduces installation costs. • Manufactured in the U.S.A. Application Product Features Application Product Features Composite / Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for Model SWG 25-380. Tool available on page 11. Watch a video demonstration atwww.itwbuildex.com SIDEWINDER® FOR WOOD - Horizontal Application SAMMYS SWIVEL HEAD™ FOR WOOD - Swivel Application #14 SH Orange Nut DriverPart # 8273910 * May require pre-drilling; consult joist manufacturer. * May require pre-drilling; consult joist manufacturer. 4 For the most up to date information, visit www.itwbuildex.com Wood Flooring Wood Joist Double Sheetrock Ceiling Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Box Qty Case Qty VERTICAL MOUNT 1/4"8002957 GST 100 1/4 x 1"210 (7/16” OSB) 670 (3/4” Ply)25 125 1/4"8003957 GST 200 1/4 x 2"1760 (Fir)25 125 3/8"8007957 GST 10 1/4 x 1"210 (7/16” OSB) 670 (3/4” Ply)300 25 125 3/8"8008957 GST 20 1/4 x 2"1760 (Fir)850 1475 25 125 3/8"8068925 GST 20-SS 1/4 x 2"1760 (Fir)850 25 125 3/8"8009925 GST 25-380 3/8 x 2-1/2"2113 (Fir)1500 25 125 3/8"8010957 GST 30 1/4 x 3"2060 (Fir)1500 1475 25 125 3/8"8069925 GST 30-SS 1/4 x 3"2060 (Fir)25 125 1/2"8013925 GST 2 1/4 x 2"1760 (Fir)25 125 1/2"8015925 GST 3 1/4 x 3"2275 (Fir)25 125 Not less than 2” nominal width (1-1/2”) Not less than 3” nominal thickness (2-1/2”) (depth or side of vertical member) #14 Black Nut Driver Part # 8113910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. #14 SW Red Nut Driver Part # 8114910 Composite / Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for GST 25-380 . Tool available on page 11. For vertical use - install in center of lower face. Minimum 2” embedment into base material for NFPA 13 compliance. • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation costs. • Manufactured in the U.S.A. SAMMYS® FOR WOOD Application Product Features Watch a video demonstration atwww.itwbuildex.com SAMMYS® FOR WOOD - Vertical Application MANUFACTURED U.S.A. OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org March 31, 2022 Leemen Fire Protection 17845 Staggs St. Reseda, CA 91335 Re: TI Fire Sprinkler Plan Review – MARU KOREAN BBQ FSS2022-0089 / 78702 HIGHWAY 111, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. The following inspections/tests are required to be witnessed by the Office of the Fire Marshal staff: 1) Overhead Rough: All installed/relocated piping must be visible. 2) Final inspection: All trim is in place, 5-Year certification is current. New/added heads shall be included in the spare head box compliment. *Water-flow signal test may be performed during the Final Inspection. All persons performing work on the automatic fire sprinkler system shall be Certified Sprinkler Fitters or Registered with the State Fire Marshal for Apprentice or Trainee classification. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 78702 HIGHWAY 111 PERMIT#: FSS2022-0089 DATE ISSUED: 3/31/2022 DESCRIPTION: MARU KOREAN BBQ – TI CONTRACTOR: LEEMEN FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.