FSS2022-0089ADDITIONAL SITES
CHRONOLOGY
CONTACTS
NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL
APPLICANT LEEMEN FIRE PROTECTION 17845 STAGG ST RESEDA CA 91335 (818)970-3312 SCOTTPLUS123@GMAI
L.COM
CONTRACTOR LEEMEN FIRE PROTECTION 17845 STAGG ST RESEDA CA 91335 (818)970-3312 SCOTTPLUS123@GMAI
L.COM
OWNER 111 LA QUINTA CENTER PARTNER 78060 CALLE ESTADO LA QUINTA CA 92253 (818)970-3312
CONDITIONS
Description: MARU / ADD AND RELOCATE SPRINKLER HEADS
Type: FIRE SPRINKLER (WEB)Subtype: TENANT IMPROVEMENT Status: FINALED Applied: 3/14/2022 ECON
Parcel No: 643220014 Site Address: 78702 HIGHWAY 111 LA QUINTA,CA 92253 Approved: 3/31/2022 KHET
Subdivision: PM 25865 Block: Lot: 16 Issued: ONLINE
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 5/3/2022 KHET
Valuation: $5,000.00 Occupancy Type: Construction Type: Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details:
FINANCIAL INFORMATION
Printed: Wednesday, April 05, 2023 1:52:16 PM 1 of 3
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2022-0089
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED
DATE
COMPLETED
DATE
RESULT REMARKS NOTES
OVERHEAD ROUGH
PIPING
KHET 4/12/2022 4/12/2022 APPROVED
OVERHEAD HYRO KHET 4/12/2022 4/12/2022 APPROVED
FIRE FINAL**KHET 5/3/2022 5/3/2022 APPROVED
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED
DATE STATUS REMARKS NOTES
PARENT PROJECTS
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
FIRE SPRINKLER
SYSTEMS - TENANT
IMPROVEMENT OVER
10 HEADS
101-0000-42420 0 $167.00 $167.00 4/1/22 WEB11228 636330742
34 CREDIT 1077869 ECON
FIRE SPRINKLER
SYSTEMS - TENANT
IMPROVEMENT OVER
10 HEADS PC
101-0000-42420 0 $83.00 $83.00 4/1/22 WEB11228 636330742
34 CREDIT 1077869 ECON
Total Paid for FIRE FEES: $250.00 $250.00
RECORDS
MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 4/1/22 WEB11228 636330742
34 CREDIT 1077869 ECON
Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00
TECHNOLOGY
ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 4/1/22 WEB11228 636330742
34 CREDIT 1077869 ECON
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
TOTALS:$266.00 $266.00
Printed: Wednesday, April 05, 2023 1:52:16 PM 2 of 3
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2022-0089
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 3/14/2022 Etrakit Contractor 1ST SUBMITTAL FIRE
SPRINKLER PLAN
Maru BBQ Fire Sprinkler
Plan.pdf 1
DOC 3/14/2022 Etrakit Contractor 1ST SUBMITTAL SPECS Maru BBQ Sprinkler Cut
Sheet.pdf 1
DOC 3/31/2022 KOHL HETRICK FSS2022-0089 -
APPROVED PLANS.pdf
FSS2022-0089 -
APPROVED PLANS.pdf 1
DOC 3/31/2022 KOHL HETRICK FSS2022-0089 - COA
AND JOB CARD.pdf
FSS2022-0089 - COA
AND JOB CARD.pdf 1
BOND INFORMATION
1ST FIRE - ETRAKIT
(2 WK)
KOHL
HETRICK 3/14/2022 3/26/2022 3/31/2022 APPROVED SEE ATTACHMENTS
1ST PERMIT TECH –
ETRAKIT (1 DAY)
PERMIT TECH
BUCKET 3/14/2022 3/15/2022 3/15/2022 COMPLETE
Printed: Wednesday, April 05, 2023 1:52:16 PM 3 of 3
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2022-0089
APPROVEDRiverside County Fire DepartmentLa Quinta Office of the Fire MarshalBy:FIRE SAFETY SPECIALIST03/31/2022 11:13:58 AMThe approval of plans and specifications does notpermit the violation, deletion, omission or faultyinstallation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remainaccessible and exposed for inspection purposesuntil approved by the Fire Department.PERMIT # -FSS2022-0089Kohl HetrickReason: I am approving this documentContact Info: 760-409-5109
General
Description
The Series TY-B, 2.8, 5.6, and 8.0
K-factor, Upright and Pendent Sprin-
klers described in this data sheet are
standard response - standard cover-
age, decorative 5 mm glass bulb type
spray sprinklers designed for use in
light, ordinary, or extra hazard, com-
mercial occupancies such as banks,
hotels, shopping malls, factories, refin-
eries, chemical plants, etc.
The recessed version of the Series
TY-B Pendent Sprinkler, where appli-
cable, is intended for use in areas with
a finished ceiling. It uses a two-piece
Style 10 (1/2 inchNPT)orStyle40(3/4
inch NPT) Recessed Escutcheon. The
Recessed Escutcheon provides 1/2
inch (12,7 mm) of recessed adjust-
ment or up to 3/4 inch (19,1 mm) of
total adjustment from the flush pen-
dentposition.Theadjustmentprovided
by the Recessed Escutcheon reduces
the accuracy to which the fixed pipe
drops to the sprinklers must be cut.
Corrosion resistant coatings, where
applicable, are utilized to extend the
life of copper alloy sprinklers beyond
that which would otherwise be ob-
tained when exposed to corrosive at-
mospheres. Although corrosion resis-
tant coated sprinklers have passed the
standard corrosion tests of the appli-
cable approval agencies, the testing is
not representative of all possible cor-
rosive atmospheres. Consequently, it
is recommended that the end user be
consulted with respect to the suitability
of these coatings for any given corro-
sive environment. The effects of ambi-
ent temperature, concentration of
chemicals, and gas/chemical velocity,
should be considered, as a minimum,
along with the corrosive nature of the
chemical towhich the sprinklerswillbe
exposed.
An intermediate level version of the
Series TY-B Pendent Sprinkler can be
obtained by utilizing the Series TY-B
Pendent Sprinkler in combination with
the Model S2 Shield.
WARNINGS
The Series TY-B Sprinklers described
herein must be installed and main-
tained in compliance with this docu-
ment, as well as with the applicable
standards of the National Fire Protec-
tion Association, in addition to the
standards of any other authorities hav-
ing jurisdiction. Failure to do so may
impair the integrity of these devices.
The owner is responsible for maintain-
ing their fire protection system and de-
vices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted
relative to any questions.
Model/Sprinkler
Identification
Numbers
TY1151 - Upright 2.8K, 1/2"NPT
TY1251 - Pendent 2.8K, 1/2"NPT
TY3151 - Upright 5.6K, 1/2"NPT
TY3251 - Pendent 5.6K, 1/2"NPT
TY4151 - Upright 8.0K, 3/4"NPT
TY4251 - Pendent 8.0K, 3/4"NPT
TY4851 - Upright 8.0K, 1/2"NPT
TY4951 - Pendent 8.0K, 1/2"NPT
Technical
Data
Approvals
UL and C-UL Listed.
FM, LPCB, and NYC Approved.
(RefertoTable Aforcomplete approval
information including corrosion resis-
tant status.)
Maximum Working Pressure
175 psi (12,1 bar)
Discharge Coefficient
K=2.8GPM/psi1/2 (40,3 LPM/bar
1/2)
K=5.6GPM/psi1/2 (80,6 LPM/bar
1/2)
K=8.0GPM/psi1/2 (115,2 LPM/bar
1/2)
Temperature Ratings
RefertoTableA
Finishes
Sprinkler: Refer to Table A
Recessed Escutcheon: White Coated,
Chrome Plated, or Brass Plated
Physical Characteristics
Frame ............ Bronze
Button ........ Brass/Copper
SealingAssembly..........
. . . . . . Beryllium Nickel w/Teflon†
Bulb ..............Glass
Compression Screw . . . . . Bronze
Deflector...........Copper
Bushing (K=2.8) . . . . . . . Bronze
† DuPont Registered Trademark
Series TY-B — 2.8, 5.6, and 8.0 K-factor
Upright, Pendent, and Recessed Pendent Sprinklers
Standard Response, Standard Coverage
Page 1 of 8 TFP151JANUARY, 2003
Technical Services:Tel: (800) 381-9312 / Fax: (800) 791-5500
Customer Service/Sales:
Tel: (215) 362-0700 / (800) 523-6512
Fax: (215) 362-5385
Page2of8 TFP151
FIGURE 1
STANDARD RESPONSE SERIES TY-B UPRIGHT (TY1151) AND PENDENT (TY1251) SPRINKLERS
2.8 K-FACTOR, 1/2 INCH NPT
1 - Frame
2-Button
3 - Sealing
Assembly
4 - Bulb
5 - Compression
Screw
6 - Deflector
7 - Bushing
*Temperature rating is indicated on deflector or adjacent to
orifice seat on frame.
**Pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 2
STANDARD RESPONSE SERIES TY-B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS
5.6 K-FACTOR, 1/2 INCH NPT
1 - Frame
2-Button
3 - Sealing
Assembly
4 - Bulb
5 - Compression
Screw
6 - Deflector *Temperature rating is indicated on deflector or adjacent to
orifice seat on frame.
**Pipe thread connections per ISO 7/1 can be provided on
special request.
2
4
5
6
PENDENT CROSS SECTION
(55,6 mm)
2-3/16"
(38,1 mm)
1-1/2"
PLATE SEATING
ESCUTCHEON 7/16" (11,1 mm)
NOMINAL
MAKE-IN
FLATS
WRENCH
SURFACE
1
3
NPT
1/2"
RECESSED PENDENT UPRIGHT
2-7/8" (73,0 mm) DIA.
(11,1 mm)
NOMINAL
MAKE-IN
7/16"
RECESSED
STYLE 10
ESCUTCHEON
(55,6 mm)
2-3/16"
1/2" NPT
DEFLECTOR
SSU
SSP DEFLECTOR
**
**
*
*
*
2
4
5
6
7
3
PLATE SEATING
ESCUTCHEON
(57,2 mm)
2-1/4"
WRENCH
(39,7 mm)
1-9/16"
FLATS
7/16"(11,1 mm)
NOMINAL
MAKE-INSURFACENPT
1/2"
2-3/16"
(55,6 mm)
SSU
DEFLECTOR
DEFLECTOR
SSP
1
SECTIONPENDENT UPRIGHT
CROSS
***
*
TFP151 Page 3 of 8
PLATE SEATING
ESCUTCHEON
(57,2 mm)
2-1/4"
WRENCH
(39,7 mm)
1-9/16"
FLATS
7/16"(11,1 mm)
NOMINAL
MAKE-INSURFACENPT
1/2"
2-3/16"
(55,6 mm)
SSU
DEFLECTOR
DEFLECTOR
SSP
SECTIONPENDENT UPRIGHT
CROSS
3
1
2
5
4
6
7
***
*
*
FIGURE 4
STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS
8.0 K-FACTOR, 1/2 INCH NPT
1 - Frame
2-Button
3 - Sealing
Assembly
4 - Bulb
5 - Compression
Screw
6 - Deflector *Temperature rating is indicated on deflector or adjacent to
orifice seat on frame.
**Pipe thread connections per ISO 7/1 can be provided on
special request.
2
4
5
6
PENDENT CROSS SECTION
(58,7 mm)
2-5/16"
(39,7 mm)
1-9/16"
PLATE SEATING
ESCUTCHEON 1/2" (12,7 mm)
NOMINAL
MAKE-INSURFACE
1
3
NPT
3/4"
RECESSED PENDENT UPRIGHT
(12,7 mm)
NOMINAL
MAKE-IN
1/2"
RECESSED
STYLE 40
ESCUTCHEON
(57,2 mm)
2-1/4"
3/4" NPT
DEFLECTOR
SSU
SSP DEFLECTOR
7
FLATS
WRENCH
2-7/8" (73,0 mm) DIA.
**
***
*
*
FIGURE 3
STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4151) AND PENDENT (TY4251) SPRINKLERS
8.0 K-FACTOR, 3/4 INCH NPT
1-Frame
2 - Button
3 - Sealing
Assembly
4 - Bulb
5 - Compression
Screw
6 - Deflector
7 - Ejection
Spring
*Temperature rating is indicated on deflector or adjacent to
orifice seat on frame.
**Pipe thread connections per ISO 7/1 can be provided on
special request.
Page4of8 TFP151
TYPE TEMP.BULB
LIQUID
NATURAL
BRASS
CHROME
PLATED
WHITE***
POLYESTER
155°F/68°C
175°F/79°C
200°F/93°C
SPRINKLER FINISH (See Note 7)
RECESSED
PENDENT
(TY3251)*
Figure 4
135°F/57°C Orange
Red
Yellow
Green
1, 2, 3, 5
NOTES:
1. Listed by Underwriters Laboratories, Inc. (UL).
2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL).
3. Approved by Factory Mutual Research Corporation (FM).
4. Approved by the Loss Prevention Certification Board (LPCB).
5. Approved by the City of New York under MEA 354-01-E.
6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377).
7. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C-UL Listed, the
sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated
Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers.
* Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable.
** 150°F/66°C Maximum Ceiling Temperature.
*** Frame and deflector only. Listings and approvals apply to all colors (Special Order).
N/A: Not Available
TABLE A
LABORATORY LISTINGS AND APPROVALS
1, 2, 5
WAX OVER
LEAD COATED
LEAD
COATED
WAX
COATED
N/A
1, 2
N/A
5.6
1/2"
NPT
PENDENT
(TY3251)
and
UPRIGHT
(TY3151)
135°F/57°C Orange
155°F/68°C Red
175°F/79°C Yellow
200°F/93°C Green
286°F/141°C Blue
360°F/182°C Mauve
1, 2, 3
RECESSED
PENDENT
(TY4251)*
Figure 5
135°F/57°C
1, 2, 3, 5
Orange
155°F/68°C Red
175°F/79°C Yellow
200°F/93°C Green
N/A
8.0
3/4"
NPT
PENDENT
(TY4251)
and
UPRIGHT
(TY4151)
135°F/57°C
155°F/68°C
175°F/79°C
200°F/93°C
286°F/141°C
360°F/182°C Mauve
Blue
Green
Yellow
Red
Orange
1, 2, 3, 4, 5, 6
1, 2, 5 1, 2, 3, 5 1, 2, 5
1**,2**, 3**, 5**1**, 2**, 5**
N/A
8.0
1/2"
NPT
PENDENT
(TY4951)
and
UPRIGHT
(TY4851)
135°F/57°C
155°F/68°C
175°F/79°C
200°F/93°C
286°F/141°C
360°F/182°C Mauve
Blue
Green
Yellow
Red
Orange
1, 2, 3, 5 N/A
K
135°F/57°C
155°F/68°C
175°F/79°C
200°F/93°C
286°F/141°C
360°F/182°C
Orange
Red
Yellow
Green
Blue
Mauve
1, 2, 3, 4, 5, 6 1, 2, 3, 5 1, 2, 3, 5 1, 2, 3, 5
1**,2**, 3**, 5**1**, 2**, 3**, 5**
N/A
PENDENT
(TY1251)
and
UPRIGHT
(TY1151)
2.8
1/2"
NPT
Operation
The glass Bulb contains a fluid which
expands when exposed to heat.When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass Bulb, allowing the sprinkler to
activate and water to flow.
Design
Criteria
The Series TY-B Pendent and Upright
Sprinklers are intended for fire protec-
tion systems designed in accordance
with the standard installation rules rec-
ognized by the applicable Listing or
Approval agency (e.g., UL Listing is
based on the requirements of NFPA
13, and FM Approval is based on the
requirements of FM’s Loss Prevention
Data Sheets). Only the Style 10 or 40
Recessed Escutcheon, as applicable,
is to be used for recessed pendent
installations.
TFP151 Page 5 of 8
FIGURE 5
SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
5.6 K-FACTOR, 1/2 INCH NPT
(57,2 mm)
2-1/4" DIA.
(73,0 mm)
2-7/8" DIA.
SPRINKLER
MOUNTING
CLOSURE
SURFACE
FACE OF
FITTING
(15,9±6,4 mm)
5/8±1/4"
(3,2 mm)
3/4" (19,1 mm)
1-1/4" (31,8 mm)
PLATE
MOUNTING
1/8"
1/4" (6,4 mm)
3/4" (19,1 mm)
SERIES
TY-B
FIGURE 7
W-TYPE 6 SPRINKLER
WRENCH
WRENCH RECESS
(END "A" USED FOR
1/2" NPT MODELS)
WRENCH RECESS
(END "B" USED FOR
3/4" NPT MODELS)
FIGURE 8
W-TYPE 7 RECESSED
SPRINKLER WRENCH
RECESS
WRENCH
WITH SPRINKLER
ENGAGEMENT
IN TO ENSURE
WRENCHING AREA
PUSH WRENCH
FIGURE 6
SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 40 RECESSED ESCUTCHEON
8.0 K-FACTOR, 3/4 INCH NPT
2-7/8" DIA.
(73,0 mm)
2-1/4" DIA.
(57,2 mm)
MOUNTING
SPRINKLER
CLOSURE
SURFACE
FITTING
FACE OF
(15,9±6,4 mm)
5/8±1/4"
MOUNTING
PLATE
1-5/16" (33,3 mm)
13/16" (20,6 mm)
(3,2 mm)
1/8"
3/4" (19,1 mm)
1/4" (6,4 mm)
SERIES
TY-B
Installation
The Series TY-B Sprinklers must be
installed in accordance with the follow-
ing instructions:
NOTES
Do not install any bulb type sprinkler if
the bulb is cracked or there is a loss of
liquid from the bulb. With the sprinkler
held horizontally, a small air bubble
should be present. The diameter of the
air bubble is approximately 1/16 inch
(1,6 mm) for the 135°F/57°C to 3/32
inch (2,4 mm) for the 360°F/182°C
temperature ratings.
A leak tight 1/2 inch NPT sprinkler joint
should be obtained with a torque of 7
to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi-
mum of 21 ft. lbs. (28,5 Nm) of torque
may be used to install sprinklers with
1/2 NPT connections. A leak tight 3/4
inch NPT sprinkler joint should be ob-
tained with a torque of 10 to 20 ft.lbs.
(13,4 to 26,8 Nm). A maximum of 30
ft.lbs. (40,7 Nm) of torque is to be used
to install sprinklers with 3/4 NPT con-
nections. Higher levels of torque may
distort the sprinkler inlet and cause
leakage or impairment of the sprinkler.
Do not attempt to make-up for insuffi-
cient adjustment in the escutcheon
plate by under- or over-tightening the
sprinkler. Readjust the position of the
sprinkler fitting to suit.
The Series TY-B Pendent and Up-
right Sprinklers must be installed in
accordance with the following instruc-
tions.
Step 1.Pendent sprinklers are to be
installed in the pendent position, and
upright sprinklers are to be installed in
the upright position.
Step 2.With pipe thread sealant ap-
plied to the pipe threads, hand tighten
the sprinkler into the sprinkler fitting.
Step 3.Tighten the sprinkler into the
sprinkler fitting using only the W-Type
6 Sprinkler Wrench (Ref. Figure 7),
except that an 8 or 10 inch adjustable
Crescent wrench is to be used for wax
coated sprinklers. With reference to
Figures1,2,3,and4theW-Type7
Sprinkler Wrench or the adjustable
Crescent wrench, as applicable is to
be applied to the wrench flats.
When installing wax coated sprinklers
with the adjustable Crescent wrench,
additional care needs to be exercised
to prevent damage to the wax coating
on the sprinkler wrench flats or frame
arms and, consequently, exposure of
bare metal to the corrosive environ-
ment. The jaws of the wrench should
be opened sufficiently wide to pass
over the wrench flats without damag-
ing the wax coating. Before wrench
tightening the sprinkler, the jaws of the
wrench are to be adjusted to just con-
tact the sprinkler wrench flats. After
wrench tightening the sprinkler,loosen
the wrench jaws before removing the
wrench.
After installation, the sprinkler wrench
flatsandframearmsmustbein-
spected and the wax coating re-
touched (repaired) whenever the coat-
ing has been damaged and bare metal
is exposed. The wax coating on the
wrench flats can be retouched by gen-
tly applying a heated 1/8 inch diameter
steel rod to the areas of wax that have
been damaged, to smooth it back over
areas where bare metal is exposed.
NOTES
Only retouching of the wax coating ap-
plied to the wrench flats and frame
arms is permitted, and the retouching
is to be performed only at the time of
the initial sprinkler installation.
The steel rod should be heated only to
the point at which it can begin to melt
the wax, and appropriate precautions
need to be taken, when handling the
heated rod, in order to prevent the
installer from being burned.
If attempts to retouch the wax coating
with complete coverage are unsuc-
cessful, additional wax can be ordered
in the form of a wax stick (the end of
which is color coded). Only the correct
color coded wax is to be used, and
retouching of wrench flats and frame
arms is only permitted at the time of
initial sprinkler installation. With the
steel rod heated as previously de-
scribed, touch the rod to the area re-
quiring additional wax with the rod an-
gled downward, and then touch the
wax stick to the rod approximately
one-half inch away from the area re-
quiring retouching. The wax will melt
and run down onto the sprinkler.
The Series TY-B Recessed Pendent
Sprinklers must be installed in ac-
cordance with the following instruc-
tions.
Step A.After installing the Style 10 or
40 Mounting Plate, as applicable, over
the sprinkler threads and with pipe
thread sealant applied to the pipe
threads, hand tighten the sprinkler into
the sprinkler fitting.
Step B. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
7 Recessed Sprinkler Wrench (Ref.
Figure 8).With reference to Figure 3 or
4, the W-Type 7 Recessed Sprinkler
Wrench is to be appliedto the sprinkler
wrench flats.
Step C.After the ceiling has been in-
stalled or the finish coat has been ap-
plied, slide on the Style 10 or 40 Clo-
sure over the Series TY-B Sprinkler
and push the Closure over the Mount-
ing Plate until its flange comes in con-
tact with the ceiling.
Page6of8 TFP151
Care and
Maintenance
The Series TY-B Sprinklers must be
maintained and serviced in accord-
ance with the following instructions:
NOTES
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system that
itcontrols,permissiontoshutdownthe
affectedfireprotectionsystem mustbe
obtained from the proper authorities
and all personnel who may be affected
by this action must be notified.
Absence of an escutcheon, which is
used to cover a clearance hole, may
delay the time to sprinkler operation in
a fire situation.
Sprinklers that are found to be leaking
or exhibiting visible signs of corrosion
must be replaced.
Automatic sprinklers must never be
painted, plated, coated or otherwise
altered after leaving the factory. Modi-
fied sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a soft bristle brush.
Care must be exercised to avoid dam-
age to the sprinklers - before, during,
and after installation. Sprinklers dam-
aged by dropping, striking, wrench
twist/slippage, or the like, must be re-
placed.Also, replace any sprinkler that
has a cracked bulb or that has lost
liquid from its bulb. (Ref. Installation
Section).
Frequent visual inspections are rec-
ommended to be initially performed for
corrosion resistant coated sprinklers,
after the installation has been com-
pleted, to verify the integrity of the cor-
rosion resistant coating. Thereafter,
annual inspections per NFPA 25
should suffice; however, instead of in-
specting from the floor level, a random
sampling of close-up visual inspec-
tions should be made, so as to better
determine the exact sprinkler condi-
tion and the long term integrity of the
corrosion resistant coating, as it may
be affected by the corrosive conditions
present.
The owner is responsible for the in-
spection, testing, and maintenance of
their fire protection system and de-
vices in compliance with this docu-
ment, as well as with the applicable
standards of the National Fire Protec-
tion Association (e.g., NFPA 25), in
addition to the standards of any other
authorities having jurisdiction. The in-
stalling contractor or sprinkler manu-
facturershouldbecontactedrelativeto
any questions.
It is recommended that automatic
sprinkler systems be inspected,
tested, and maintained by a qualified
Inspection Service.
Limited
Warranty
Products manufactured by Tyco Fire
Products are warranted solely to the
original Buyer for ten (10) years
against defects in material and work-
manship when paid for and properly
installed and maintained under normal
use and service. This warranty will ex-
pire ten (10) years from date of ship-
ment by Tyco Fire Products. No war-
ranty is given for products or
components manufactured by compa-
nies not affiliated by ownership with
Tyco Fire Products or for products and
components which have been subject
to misuse, improper installation, corro-
sion, or which have not been installed,
maintained, modified or repaired in ac-
cordance with applicable Standards of
the National Fire Protection Associa-
tion, and/or the standards of any other
Authorities Having Jurisdiction. Mate-
rials found by Tyco Fire Products to be
defective shall be either repaired or
replaced, at Tyco Fire Products’ sole
option. Tyco Fire Products neither as-
sumes, nor authorizes any person to
assume for it, any other obligation in
connection with the sale of products or
parts of products. Tyco Fire Products
shall not be responsible for sprinkler
system design errors or inaccurate or
incomplete information supplied by
Buyer or Buyer’s representatives.
IN NO EVENT SHALL TYCO FIRE
PRODUCTS BE LIABLE, IN CON-
TRACT, TORT, STRICT LIABILITY OR
UNDER ANY OTHER LEGAL THE-
ORY, FOR INCIDENTAL, INDIRECT,
SPECIAL OR CONSEQUENTIAL
DAMAGES, INCLUDING BUT NOT
LIMITED TO LABOR CHARGES, RE-
GARDLESS OF WHETHER TYCO
FIRE PRODUCTS WAS INFORMED
ABOUT THE POSSIBILITY OF SUCH
DAMAGES,ANDINNOEVENT
SHALL TYCO FIRE PRODUCTS’ LI-
ABILITY EXCEED AN AMOUNT
EQUAL TO THE SALES PRICE.
THE FOREGOING WARRANTY IS
MADE IN LIEU OF ANY AND ALL
OTHERWARRANTIESEXPRESSOR
IMPLIED,INCLUDINGWARRANTIES
OF MERCHANTABILITY AND FIT-
NESS FOR A PARTICULAR PUR-
POSE.
TFP151 Page 7 of 8
Ordering
Procedure
When placingan order,indicate the full
product name. Refer to the Price List
for complete listing of Part Numbers.
Contact your local distributor for avail-
ability.
Sprinkler Assemblies with NPT
Thread Connections:
Specify: (Specify Model/SIN), Stand-
ard Response, (specify K-factor),
(specify temperature rating), Series
TY-B (specify Pendent or Upright)
Sprinkler with (specify type of finish or
coating), P/N (specify from Table B).
Recessed Escutcheon:
Specify: Style (specify) Recessed Es-
cutcheon with (specify finish), P/N
(specify).
1/2" (15 mm)
Style 10
Chrome Plated . . . . . . . . . P/N 56-701-9-010
1/2" (15 mm)
Style 10
White Color
Coated . . . . . . . . . . . . . . . P/N 56-701-4-010
1/2" (15 mm)
Style 10
Brass Plated. . . . . . . . . . . P/N 56-701-2-010
3/4" (20 mm)
Style 40
Chrome Plated . . . . . . . . . P/N 56-700-9-010
3/4" (20 mm)
Style 40
White Color
Coated . . . . . . . . . . . . . . . P/N 56-700-4-010
3/4" (20 mm)
Style 40
Brass Plated. . . . . . . . . . . P/N 56-700-2-010
Sprinkler Wrench:
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387.
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001.
Wax Sticks:
(for retouching wrench damaged
wax coating)
Specify: (Specify color) color coded
Wax Stick for retouching (specify tem-
perature rating) temperature rated Se-
ries TY-B Sprinklers, P/N (specify).
Black for 135°F . . . . . . . . . . . . P/N 56-065-1-135
Red for 155°F . . . . . . . . . . . . . P/N 56-065-1-155
Yellow for 175°F . . . . . . . . .P/N 56-065-1-175
Blue for 200°F and
286°F . . . . . . . . . . . . . . . . . P/N 56-065-1-286
NOTES
Each wax stick is suitable for retouch-
ing up to twenty-five sprinklers.
The wax used for 286°F sprinklers is
the same as for 200°F sprinklers, and,
therefore,the286°Fsprinklerislimited
to the samemaximumceilingtempera-
ture as the 200°F sprinkler (i.e.,
150°F).
Page8of8 TFP151
TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446
P/N 57 — XXX — X — XXX
360°F/182°C
155°F/68°C
360
155
TEMPERATURE
RATING
135°F/57°C135
8.0K UPRIGHT (1/2"NPT)
561
560
1
SPRINKLER
TABLE B
PART NUMBER SELECTION
SERIES TY-B PENDENT AND UPRIGHT SPRINKLERS
8.0K PENDENT (1/2"NPT)
175°F/79°C
286
200°F/93°C200
286°F/141°C
175WHITE POLYESTER
NATURAL BRASS
9
4
MODEL/SIN
CHROME PLATED
7 LEAD COATED
6 WAX COATED
286°F/141°C MAX.
8 WAX OVER LEAD
286°F/141°C MAX.
590 8.0K UPRIGHT (3/4"NPT)
591 8.0K PENDENT (3/4"NPT)
530 2.8K UPRIGHT (1/2"NPT)
531 2.8K PENDENT (1/2"NPT)
TY1151
TY1251
TY4151
TY4251
TY4851
TY4951
570
571
5.6K UPRIGHT (1/2"NPT)
5.6K PENDENT (1/2"NPT)
TY3151
TY3251
Office/Manufacturing Facility •1375 Sampson Ave. •Corona, CA 92879 •Ph: 951.737.5599 •Fax: 951.737.0330
Customer Service •800.786.5266
www.tolco.com
90
wwwwww..ttoollccoo..ccoomm
Revision 5/24/2001
™
®
a brand of
Fig. 200 - “Trimline” Adjustable Band Hanger
Size Range — 1/2" thru 8" pipe
Material — Carbon Steel, Mil. Galvanized to G90
specifications
Function — For fire sprinkler and other general piping
purposes. Knurled swivel nut design permits hanger
adjustment after installation.
Features —
• (1/2" thru 2") Flared edges ease installation for
all pipe types and protect CPVC plastic pipe from
abrasion. Captured design keeps adjusting nut
from separating with hanger. Hanger is easily
installed around pipe.
•(21/2" thru 8" Spring tension on nut holds it
securely in hanger before installation. Adjusting
nut is easily removed.
Approvals — Underwriters’ Laboratories listed (1/2"
thru 8") in the USA (UL)and Canada (cUL) for steel
and CPVC plastic pipe and Factory Mutual Engineering
Approved (3/4" thru 8"). Conforms to Federal
Specifications WW-H-171E, Type 10 and Manufacturers
Standardization Society SP-69, Type 10.
Maximum Temperature — 650°F
Finish — Mil. Galvanized. For Stainless Steel materi-
als, order TOLCO™ Fig. 200WON.
Order By — Figure number and pipe size
Dimensions • Weights
Pipe Rod Size Max. Rec. Approx.
Size Inch Metric
ABLoad Lbs. Length
1/2 3/8 8mm or 10mm 3
1/8 25/8 400 11
3/4 3/8 8mm or 10mm 3
1/8 21/2 400 11
1 3/8 8mm or 10mm 3
3/8 25/8 400 12
11/4 3/8 8mm or 10mm 3
3/4 27/8 400 13
11/2 3/8 8mm or 10mm 3
7/8 27/8 400 14
2 3/8 8mm or 10mm 4
1/2 3 400 15
21/2 3/8 10mm 5
5/8 41/8 600 27
3 3/8 10mm 5
7/8 4 600 29
31/2 3/8 10mm 7
3/8 51/4 600 34
4 3/8 10mm 7
3/8 5 1000 35
5 1/2 12mm 9
1/8 61/4 1250 66
6 1/2 12mm 10
1/8 63/4 1250 73
8 1/2 12mm 13
1/8 83/4 1250 136
S3 - 3
Comparison to L.W.T. PipesComparison to Schedule 40
Specifications & Approvals
Dyna-Thread®
Full Line Sch-40 Replacement
Dyna-Thread® offers the life expectancy of Sch-40 with superior hydraulics and greater value.
Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety
and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages.
• Dyna-Thread’s inside diameter is up
to 3.6% larger than Sch-40 giving it
superior hydraulics. And, when used
in combination with Dyna-Flow pipe,
down sizing often occurs.
• Dyna-Thread is fully listed and
approved by UL, ULC, and FM for
fire sprinkler applications.
• The life expectancy of Dyna-Thread
and Sch-40 are equal based on the
calculated wall thicknesses per UL.
• The consistent quality of steel used to
make Dyna-Thread facilitates smooth
threading and lower maintenance
costs.
• The exterior of Dyna-Thread is
protected by a clean, durable mill
coating for extended shelf life and
easy paint application.
• More wall thickness at the thread
(CRR=1.00) gives Dyna-Thread
better life expectancy than lightwall
threadable pipe joints.
• Unlike lightwall threadable pipe,
Dyna-Thread has no thread gauge
warning.
• Dyna-Thread is approved for
standard hanger spacing (15 ft.
O.C.), can be used as earthquake
sway bracing, and is safe to use as
drops.
• Dyna-Thread is safer to weld on.
• Dyna-Thread is more widely
accepted than lightwall threadable
where Sch-40 is specified.
Super 40/Dyna-Thread pipe is
manufactured to meet: ASTM A-135,
Grade A and is in compliance with
NFPA-13. All sizes of Super 40/Dyna-
Thread are rated at 300 psi working
pressure. Super 40/Dyna-Thread is UL
and ULC Listed for wet, dry deluge and
pre-action sprinkler systems and FM
Approved for use in wet systems. Super
40/Dyna-Thread can be “hot-dip”
galvanized to meet FM requirement for
dry systems. Super 40/Dyna-Thread is
approved for all threaded couplings and
welded outlets and is suitable for all
roll-grooved, and plain-end fittings.
(See listing information).
Specifications
NPS Nominal I.D. Wt. Wt. (H2O Filled) Pcs/ Wt/Lift (21')Wt/Lift (24')Wt/Lift (25')
In; mm In; mm Lbs/Ft; Kg/m Lbs/Ft; Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg
1" 1.080 1.330 1.75 70 1955 2234 2327
25 27.4 2.0 2.60 70 887 1013 1056
11⁄4" 1.408 1.870 2.54 51 2002 2288 2384
32 35.8 2.8 3.78 51 908 1038 1081
11⁄2" 1.639 2.290 3.22 44 2115 2418 2519
40 41.6 3.4 4.79 44 959 1097 1143
2" 2.104 3.050 4.57 30 1921 2196 2287
50 53.4 4.5 6.80 30 871 996 1037
• With its increased strength and lighter
weight, Dyna-Thread reduces
installation fatigue and is ideal for
retro-fit applications.
Corrosion Resistance Ratio (CRR) is a
UL (Underwriters Laboratory) term for
the estimated life expectancy of a pipe
joint. This is based on the calculated
wall thickness at the base of the first
exposed thread, assumed to be the
weakest point of the pipe length. Dyna-
Thread and Sch-40 have the same
calculated wall thicknesses at this point
and are both assigned the same CRR of
1.00.
The internal surface of all black Allied
Tube & Conduit Fire Sprinkler pipe
products up to 4.5000” in diameter is
coated with our new Antibacterial
Formula, “ABF”. In scientific laboratory
test, ABS proved to have superior
resistance to microbial colonization of
pipe walls, thereby delaying or possibly
preventing the onset of
Microbiologically Influenced corrosion
(MIC) when the First Sprinkler System
is first installed.
FM
Listed Approved Listed
16100 S. Lathrop • Harvey, IL 60426
11350 Norcom Rd. • Philadelphia, PA 19154
2525 N. 27 th Ave. • Phoenix, AZ 85009
Customer Service:
(800) 882-5543
Fax 708-339-1806
5 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETENot less than 2” nominal width
(1-1/2”) up to 3-1/2” pipe; not less than
3” (2-1/2”) nominal width 4” & 5” pipe
Minimum 2-1/2” from bottom for
branch lines. Minimum 3” from bot-
tom for main lines. Exception: This
requirement shall not apply to 2” or
thicker nailing strips resting on top of
steel beams.
Floor Joist
Approvals Rod
Size
Part
Number Model Screw
Descriptions
Ultimate
Pullout (lbs)
UL Test
Load (lbs)
Box
Qty
Case
Qty
HORIZONTAL MOUNT
1/4"8019957 SWG 200 1/4 x 2"1725 (Fir)25 125
3/8"8020957 SWG 10 1/4 x 1"622 (Fir)300 25 125
3/8"8021957 SWG 20 1/4 x 2"1725 (Fir)1050 25 125
3/8"8073925 SWG 20-SS 1/4 x 2"1725 (Fir)850 25 125
3/8"*8022925 SWG 25-380 3/8 x 2-1/2"2249 (Fir)1500 25 125
3/8"8023925 SWG 30 1/4 x 3"1884 (Fir)25 125#14 SW Red
Nut Driver
Part # 8114910
• No pre-drilling required.
• Quick to install using the Sammy
Nut Driver with an 18V cordless
drill/driver.
• Saves time from traditional
methods.
• Reduces installation costs.
• Manufactured in the U.S.A.
Approvals Rod
Size
Part
Number Model Screw
Descriptions
Ultimate
Pullout (lbs)
UL Test Load
(lbs)
FM Test
Load (lbs)
Min
Thickness
Box
Qty
Case
Qty
SWIVEL MOUNT
3/8"8139957 SH-GST 20 1/4 x 2"1257 (Fir)1050 1475 25 125
3/8"*8269957 SH-GST/CST 20 5/16 x 1-3/4”
1903 Dim. Lumber
1406 @ 45°off vertical
Dim. Lumber
1500
850 @ 45°25 125
1/2”8303957 SH-GST/CST 2.0 5/16 x 1-3/4”
903 Dim. Lumber
1406 @ 45°off vertical
Dim. Lumber
25 125
#14 Black Nut DriverPart # 8113910
• Eliminates distortion of threaded rod.
• Accommodates up to 3 ½” x 12 pitch roof.
• Allows 17° deflection from vertical.
• Saves time from traditional methods. • Reduces installation costs.
• Manufactured in the U.S.A.
Application Product Features
Application Product Features
Composite / Truss
Consult truss manufacturer for
recommended installation point.
*Pre-drilling may be required for Model
SWG 25-380. Tool available on page 11.
Watch a video demonstration atwww.itwbuildex.com
SIDEWINDER® FOR WOOD - Horizontal Application
SAMMYS SWIVEL HEAD™ FOR WOOD - Swivel Application
#14 SH Orange Nut DriverPart # 8273910
* May require pre-drilling; consult joist manufacturer.
* May require pre-drilling; consult joist manufacturer.
4 For the most up to date information, visit www.itwbuildex.com
Wood Flooring
Wood Joist
Double Sheetrock
Ceiling
Approvals Rod
Size
Part
Number Model Screw
Descriptions
Ultimate
Pullout (lbs)
UL Test
Load (lbs)
FM Test
Load (lbs)
Box
Qty
Case
Qty
VERTICAL MOUNT
1/4"8002957 GST 100 1/4 x 1"210 (7/16” OSB)
670 (3/4” Ply)25 125
1/4"8003957 GST 200 1/4 x 2"1760 (Fir)25 125
3/8"8007957 GST 10 1/4 x 1"210 (7/16” OSB)
670 (3/4” Ply)300 25 125
3/8"8008957 GST 20 1/4 x 2"1760 (Fir)850 1475 25 125
3/8"8068925 GST 20-SS 1/4 x 2"1760 (Fir)850 25 125
3/8"8009925 GST 25-380 3/8 x 2-1/2"2113 (Fir)1500 25 125
3/8"8010957 GST 30 1/4 x 3"2060 (Fir)1500 1475 25 125
3/8"8069925 GST 30-SS 1/4 x 3"2060 (Fir)25 125
1/2"8013925 GST 2 1/4 x 2"1760 (Fir)25 125
1/2"8015925 GST 3 1/4 x 3"2275 (Fir)25 125
Not less than
2” nominal width
(1-1/2”)
Not less than
3” nominal
thickness (2-1/2”)
(depth or side
of vertical member)
#14 Black
Nut Driver
Part # 8113910
SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into
contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.
#14 SW Red
Nut Driver
Part # 8114910
Composite / Truss
Consult truss manufacturer for
recommended installation point.
*Pre-drilling may be required for GST
25-380 . Tool available on page 11.
For vertical use -
install in center of lower face.
Minimum 2” embedment into base
material for NFPA 13 compliance.
• No pre-drilling required.
• Quick to install using the Sammy
Nut Driver with an 18V cordless
drill/driver.
• Saves time from traditional
methods.
• Reduces installation costs.
• Manufactured in the U.S.A.
SAMMYS® FOR WOOD
Application Product Features
Watch a video demonstration atwww.itwbuildex.com
SAMMYS® FOR WOOD - Vertical Application
MANUFACTURED U.S.A.
OFFICE OF THE FIRE MARSHAL – LA QUINTA
78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074
• www.rvcfire.org
March 31, 2022
Leemen Fire Protection
17845 Staggs St.
Reseda, CA 91335
Re: TI Fire Sprinkler Plan Review – MARU KOREAN BBQ
FSS2022-0089 / 78702 HIGHWAY 111, LA QUINTA, CA 92253
The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County
Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions.
The following inspections/tests are required to be witnessed by the Office of the Fire Marshal staff:
1) Overhead Rough: All installed/relocated piping must be visible.
2) Final inspection: All trim is in place, 5-Year certification is current. New/added heads shall be
included in the spare head box compliment.
*Water-flow signal test may be performed during the Final Inspection.
All persons performing work on the automatic fire sprinkler system shall be Certified Sprinkler Fitters or
Registered with the State Fire Marshal for Apprentice or Trainee classification.
The Fire Department approved plans and conditions letter must be at the job site.
Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for
inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131.
All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal
staff at (760)777-7074.
Kohl Hetrick - Fire Safety Specialist
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
RIVERSIDE COUNTY FIRE PROTECTION PLANNING
RECORD OF INSPECTIONS / PERMIT CARD
THIS CARD IS TO REMAIN ON SITE AT ALL TIMES.
INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE.
JOB
ADDRESS: 78702 HIGHWAY 111 PERMIT#: FSS2022-0089 DATE
ISSUED: 3/31/2022
DESCRIPTION: MARU KOREAN BBQ – TI CONTRACTOR: LEEMEN FIRE PROTECTION
HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS
Thrust block pre-pour Door fan test
UG rough piping Abort test
UG hydro Mechanical shutdown
Flush Detector test
Final E F Deluge/pre-action
SPRINKLER U.G. Final E F
Thrust block pre-pour UST/AST TANK
UG rough piping Installation
UG hydro Removal
Flush Emergency shut off
Final E F Primary piping
FIRE SPRINKLER Secondary piping
Weld inspection Dispensers & shear valves
Overhead rough piping Final E F
Overhead hydro MISC. INSPECTIONS
UG flush / OK to connect Spray booths
Main drain/inspectors’ test Hood/duct extinguishing
High pile storage High pile rack storage
In-rack sprinklers H.P. vents/access/corridors
Hose racks Tract access/hydrant verification
Final E F Access & Address verification
HOOD EXTINGUISHING OTHER CONST. PERMIT
Detection system
Function test
Gas/electrical shut-off
Nozzle model/placement
Fire alarm connection
Final E F
SPRAY BOOTHS FIRE CODE PERMIT(S)
Installation
Air flow test
Mechanical interlock
Extinguishing system
Fire alarm connection
Final E F
FIRE ALARM KNOX SYSTEM
Rough-wire inspection Building Knox box
Function test Gate access Knox box/padlock
Duct detectors/velocity BUILDING INSPECTIONS
24 hr. battery test T/I final
Sprinkler monitoring Shell final
Final E F Final for occupancy
FINAL INSPECTION DATE: INSPECTORS SIGNATURE:
**WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE**
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
INSPECTION NOTES
1. Sway bracing and hangers will be inspected at the time of rough piping inspection.
2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler
Systems)
3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required.
4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test.
5. Contractor shall supply all testing equipment, access and operating instructions at time of test.
6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the
affected system to be covered or hidden.
POLICIES ON FIELD INSPECTIONS
A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when
scheduling inspections. For City of La Quinta inspections call: (760) 777-7131.
B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence
without approved plans.
C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required
to schedule the necessary inspections and be present on site for inspections.
D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not
on site or where previously noted corrections have not been completed.
E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into
the structure until clearance has been granted by the Fire Dept and Building Official.
F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance
has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official.
INSPECTION NOTES:
THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE
AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS.
THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180
DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE.
THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE
REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.