FSS2022-0103Description: TI OF EXISTING NFPA 13 SYSTEM Type: FIRE SPRINKLER (WEB) Subtype: Status: FINALED Applied: 3/22/2022 ECON COMMERCIAL/INDUSTRIAL Approved: 4/22/2022 KHET Parcel No: 600390017 Site Address: 79215 CORPORATE CENTRE DR STE 120 LA QUINTA,CA 92253 Subdivision: PM 29351 Block: Lot: 7 Issued: ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 5/31/2022 KHET Valuation: $6,500.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: TI of existing system for new Dr. Office ADDITIONAL CHRONOLOGY • NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT WORLD FIRE PROTECTION INC 41-905 BOARDWALK STE B PALM DESERT CA 92211 (760)565-6030 bchapman@worldfirep rotection.com CONTRACTOR World Fire Protection 41905 Boardwalk Suite B Palm Desert CA 92211 (760)565-6030 bchapman@worldfirep rotection.com OWNER BLOOD BANK OF SAN BERNARDINO PO BOX 1429 SAN BERNARDINO CA 92253 (760)565-6030 Printed: Wednesday, April 05, 2023 2:37:45 PM 1 of 4 WsYsrEMS DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - TENANT 101-0000-42420 0 $167.00 $167.00 5/11/22 WEB11706 637109882 CREDIT 1049720 ECON IMPROVEMENT OVER 15 10 HEADS FIRE SPRINKLER SYSTEMS - TENANT 101-0000-42420 0 $333.00 $333.00 5/11/22 WEB11706 637109882 CREDIT 1049720 ECON IMPROVEMENT OVER 15 10 HEADS PC Total Paid for FIRE FEES: $500.00 $500.00 RECORDS 101-0000-42416 0 $11.00 $11.00 5/11/22 WEB11706 637109882 CREDIT 1049720 ECON MANAGEMENT FEE 15 Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY 502-0000-43611 0 $5.00 $5.00 5/11/22 WEB11706 637109882 CREDIT 1049720 ECON ENHANCEMENT FEE 15 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 . 00 $516.00 SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES Printed: Wednesday, April 05, 2023 2:37:45 PM 2 of 4 CRWSY5TEM5 FIRE INSPECTOR I KHET I I I DISAPPROVE OVERHEAD ROUGH KHET 5/18/2022 5/18/2022 APPROVED PIPING FIRE FINAL" LIN 5/31/2022 1 5/31/2022 1 APPROVED PARENT PROJECTS Performed impromptu inspection at the project location to evaluate World Fire Protection compliance with previous warnings associated with performing work prior to permit issuance and work performed by uncertified Fire Sprinkler Fitters. Met GC Superintendent Josh and confirmed that work was performed on Thursday or Friday 4/21 or 4/22. Josh gave tour of the work performed and I observed items of concern, including no coupon recovery, improper hanger attachments and un-proposed/permitted flex drop installation. Asked Josh to request from World Fire Protection a list of individuals that performed work on this project location. LQ OFM will consider appropriate enforcement. REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE - ETRAKIT KOHL 3/22/2022 4/5/2022 4/22/2022 APPROVED SEE ATTACHMENTS (2 WK) HETRICK 1ST PERMIT TECH — PERMIT TECH 3/22/2022 3/23/2022 3/23/2022 COMPLETE ETRAKIT (1 DAY) BUCKET Printed: Wednesday, April 05, 2023 2:37:45 PM 3 of 4 WsYsrEMS ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 3/22/2022 Etrakit Contractor 1ST SUBMITTALSIDEWINDERS Sammy STEEL SIDE.pdf 1 DOC 3/22/2022 Etrakit Contractor 1ST SUBMITTAL VK302 VIKING QR SEMI PEND 1 VK302.pdf DOC 3/22/2022 Etrakit Contractor 1ST SUBMITTAL PIPING DR HSU TI PIPING FS- 1 PLAN 1.pdf DOC 3/22/2022 Etrakit Contractor 1ST SUBMITTAL PIPE BULLMOOSE PIPE.pdf 1 DOC 3/22/2022 Etrakit Contractor 1ST SUBMITTAL CLAMP FIG 65 C CLAMP.pdf 1 1ST SUBMITTAL PIPE DOC 3/22/2022 Etrakit Contractor HANGERS AND FIG 69 RETAINING 1 STRAP.pdf SUPPORT DOC 3/22/2022 Etrakit Contractor 1ST SUBMITTAL FLANGE FIG 78 CEILING FLG.pdf 1 DOC 3/22/2022 Etrakit Contractor 1ST SUBMITTAL PIPE FIG 200 RING.pdf 1 HANGERS DOC 3/22/2022 Etrakit Contractor 1ST SUBMITTAL PIPEFITTINGS MI Pipe_Fittings.pdf 1 DOC 3/22/2022 Etrakit Contractor 1ST SUBMITTAL Sammy STEEL 1 VERTICAL MOUNT BOTTOM.pdf DOC 4/22/2022 KOHL HETRICK FSS2022-0103 - FSS2022-0103 - 1 APPROVED PLANS.pdf APPROVED PLANS.pdf DOC 4/26/2022 KOHL HETRICK FSS2022-0103 - COA FSS2022-0103 - COA 1 AND JOB CARD.pdf AND JOB CARD.pdf Printed: Wednesday, April 05, 2023 2:37:45 PM 4 of 4 WsYsrEMS .rxom <axo ..a Ro ' xar/ cxR. m xis ARM-0VER DETAIL BREAK ROOM �611 I uu 1 1 1 1 E '® ccNc N mox a� ripEau �uA mu x xr ecnu fox yrEL ox co,eu. xoai OI a/a- A�� TxR.o Roo xo mox 15- MEM NG TG STEEL FRAMING 16 Pl HANGER To METAL pE x1NG FTA 9 �T LEGEND o r-alTipmu w. ill wommmommmom. ■nmmnmmmm I I 1 I I 1 E,♦ I o I OE 1 I I 1 a, o , DATA VITALS 2 IEO ENDEN TO REMAM NO D' CHANGES MENS D' ,® j� ITALS 1 '® WOMANS E, SOL III ElIXIYE111 F1-3i■�a 1 m1i1■■L---'_ °INE34 ■h�L7■1ili��nn f■!I■■1 ■■MO I �• ■0■ I■■1 -- = i mmmml I�■■ii■ ■■■■■ .... ■■■■■■■■■1 -- 0101301 1II■120®®1 11■■■■1, i��l l�i■■■■■■■■1 j■■!■■ ®RFMAI I■■■■■■■■■■1 ] ■Gl■■'L■Ci■II■ �� G■■■■■■■■■► �_ , ■�■■■!�■■ I® NONE■■■■■■■■■■■1 �, ■[':III■�■■Cr�■■F i�� �?�■..l III■■; 111 ■■■■■■II■■11—I■■■0_■■■■1 1 1 TO BOTTOM SCOPE — KEY PLAN SUITE 120 , SITE Wr VICINITY MAP PROJECT IAFORJ.ATIOA APPLICABLE CODES PROJECT DESCR PROJECT T.I. NOTE i La Quinta Office of the Fire Marshal BY: Kohl Hetrick^ "b> ,o` FIRE SAFETY SPECIALIST 04/22/2022 4:32:05 PM The approval of plans and specifications does no[ permit the violation, deletion, omission or faulty installation of any requirements of Title 24 or any Local Ordinances. Construdion shall remain ssible anse d expod for inspection purposes until app..d by the Fire Department. CD z8 �= z QL�s z Lj Z U m o �N W<aAi L'i_ = O 0 ry m NORTH DRAWING NO. FN3-1 33 #14 SW Red Nut Driver Part # 8114910 no pr e-dr�ulrged Product Features • Made with Teks® self -drilling fasteners - no pre -drilling required. • Install into steel range from 22 gauge —1/2" thicknesses. • Saves time from traditional methods. • Reduces installation cost. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. 1/4" 8047957 SWD 100 1/4-14 x 1"TEKS 3 1477 (16 ga.) .060"-16 ga 3116" 25 125 1/4" 8049957 SWDR 100 * 1/4-20 x 1"TEKS 3 1900 (20 ga.) .036"-20 ga 3/16" 25 125 3/8" 8050957 SWD 10 1/4-14 x 1"TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 3/8" 8080925 SWD 10-SS 1/4-14 x 1" TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 3/8" 8051957 SWD 15 1/4-14 x 1-112" TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 3/8" 8081925 SWD 15-SS 1/4-14 x 1-112" TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 3/8" 8052957 SWD 20 1/4-14 x 2" TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 3/8" 8053957 SWD 516 5/16-18 x 1-1/4" TEKS 3 2480 (20 ga.) .036"-20 ga 1/8" 25 125 eO 3/8" 8055957 SWDR 1 * 1/4-20 x 1"TEKS 3 1900 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 3/8" 8054957 SWDR 1-1/2 * 12-24 x 1-1/2" TEKS 5 2375 (3/16") 1500 1475 .187"-3/16" 1/2" 25 125 Q 3/8" 8056957 SWDR 516 * 5/16-18 x 1-1/4" TEKS 3 2480 (20 ga.) 1500 1475 .036"-20 ga 1/8" 25 125 3/8" 8057957 SWT 15 12-24 x 1-1/2" TEKS 5 237 (3/16") .187"-3/16" 1/2" 25 125 *Includes retaining nut Performance Data - Steel Gauge No. 26 24 22 20 18 16 14 12 3116" 114" Nominal Decimal Equivalent .018 .024 .030 .036 .048 .060 .075 .105 1 .188 1 .250 Ultimate Pullout Fastener Values (avg. lb MYS Steel Gauge (lbs.) Model Dia. Pt. 20 18 16 14 12 3116 1/4 DST 1/4 #3 446 613 970 1145 1544 3190 DST 516 5/16 #3 457 568 1209 1712 2422 TEK 50 #12 #5 487 699 913 1527 3270 3593 DSTR 1.1/2" #12 #5 3270 3593 DSTR 1" 1/4 #3 1510 DSTR 516 5/16 #3 2200 =Ultimate Pullout Values Fastener (avg. lbs. ultimate) - SIDEWINDERS Steel Gauge (lbs.) Model Dia. Pt. 20 18 16 14 12 3/16 1 114 SWD 1/4 #3 1477 SWDR 1.1/2" #12 #5 2375 SWDR 1" 1/4 #3 1900 1900 SWDR 516 1 5/16 #3 1 2480 2480 Aluminum Curtain Wall Extrusion Ultimate Pullout Values A (average lbs. ultimate) Fastener Thickness Model Dia. Pt. .114 .092 .365 .132 DST 10 114 #3 1265 2750 SWD 10 1A #3 1120 1420 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. PH-13 Pipe Hangers ����ipe.ha -Vol er "Owl ,� Su r t'S, Iro 'T. t Powering business worldwide As a global diversified power management company, we help customers worldwide manage the power needed for buildings, aircraft, tri1C1(s, cars, machinery and businesses. Eaton's innovative technologies help customers manage electrical, hydraulic and mechanical power more reliably, efficiently, safely and sustainably. F I -T*N Powering Business Worldwide We deliver: Electrical solutions that use less energy, improve power reliability and make the places we live and work safer and more comfortable • Hydraulic and electrical solutions that enable machines to deliver more productivity without wasting power Aerospace solutions that make aircraft lighter, safer and less costly to operate, and help airports operate more efficiently Vehicle drivetrain and powertrain solutions that deliver more power to cars, trucks and buses, while reducing fuel consumption and emissions We provide integrated solutions that help make energy, in all its forms, more practical and accessible. With 2012 sales of $16-3 billion, Eaton has approximately 103,000 employees around the world and sells products in more than 175 countries. Introduction B-Line is a leading manufacturer and fabricator of metal products used in the support of pipe and equipment for industrial, residential, commercial, utility, and OEM installations. B-Line is proud of the exacting standards of research, design, engineering, and manufacturing that go into each and every product that comprise our pipe hanger product line. Our customers have access to the most complete support systems offered in the industry, including pipe hangers, metal framing, cable tray, slotted angle, seismic bracing, fasteners, telecom, enclosures and anchors. Many of B-Line's products are listed by Underwriters' Laboratories, Inc. and FM Global approved for fire sprinkler system installations. All B-Line products are manufactured to meet or exceed industry standards set for their design and manufacture. B-Line products are produced in five modern plants consisting of over 1,000,000 square feet. These facilities are located in Highland, Illinois; Troy, Illinois; Reno, Nevada; Corona, California and Sherman, Texas. Regional sales and distribution centers are located throughout the United States stocking standard B-Line products for quick service and delivery. This catalog is designed to be helpful to engineers and contractors in the application and selection of pipe hangers, supports and seismic bracing for construction and maintenance. If a unique application requires a special product not included in this catalog, B-Line engineering personnel are ready to furnish design consultation and realistic material estimates. In addition, sales representatives with engineering expertise are located throughout the United States and abroad for your convenience. WARNING All hanger products in this catalog are intended for installation and service as illustrated or described. Do not use them for any purposes other than those described in this catalog. Products that are used for unintended purposes could fail, resulting in severe personal injury or death. Examples of misapplications which could cause severe personal injury or death include, but are not limited to: • Using a beam clamp on a beam other than those described in the catalog; • Using concrete inserts as anchors for pulling pipe up to the required elevation; • Suspending clevis hangers, one under another, which could result in an accumulative load that is greater than that which the pipe hanger will support. B-Line pipe hanger and support products are manufactured in accordance with industry standards. Our customers should exercise care to use these products properly so as to avoid potential accidents. Contact B-Line for assistance with proper installation and use of the products in this catalog. MSS Manufacturers Standardization Society BSI of the ISO 9001:2008 Valve and Fitting Industry, Inc. C u` u5 FM o5F?pd 0 LISTED APPROVED Eaton's B-Line Business 509 West Monroe Street Highland, Illinois 62249-0326 Phone:800-851-7415 Fax: 618-654-1917 RI www.cooperbline.com B-Line by FA-N Pipe Hangers & Supports Table of Contents Applications & Pictorial Index .................................... 3-16 _ Strut Systems Information .......................................... 17-18 Technical Data Materials & Corrosion.......................................................... 19 Finishes & General Information .......................... 19-20 Recommended Specifications ............................. 21-26 Beam Clamps C-Clamps................................................................................ 28-34 Bottom Beam Clamps ................................................. 35-43 TopBeam Clamps.................................................................. 44 Trus Joist & Angle Iron Beam Clamps ......... 45-46 Pipe Hangers Clevis Hangers................................................................... 48-58 `J' Hangers..................................................................................... 54 BandHangers..................................................................... 59-62 Split Clamps & Hangers, Rings ................. 63-66, 71 Wall Mount Lay -In Hangers ............................................ 66 WireHangers....................................................................... 67-69 SpringHangers.......................................................................... 70 Pipe Clamps Risers.......................................................................................... 74-75 Underground Clamps ................................................... 76-77 Clamps...................................................................................... 78-88 Straps......................................................................................... 89-92 CPVC Hangers................................................................. 93-102 Plastic KWIK-CLIPTM.............................................. 103-104 Pipe Rollers & Roller Supports Roller Hangers............................................................. 106-107 Roller Supports............................................................ 108-116 Roller Stands................................................................. 117-119 Spring Cushion Roller Hanger .................................. 120 Rollers.................................................................................. 121-122 Pipe Supports, Guides, Shields & Saddles Calcium Silicate Shields ................................................. 124 Stands & Supports ................................................... 125-139 Isolators, Guides & Anchors ............................ 140-146 Slides, Shields, Saddles ....................................... 147-166 TOLCOTM Seismic Bracing Sway Bracing Pipe Clamps .............................. 168-172 Sway Bracing Attachments .............................. 173-183 Mechanical Fast Clamps ................................................ 184 Pre -Stretched Aircraft Cable ...................................... 185 Cable Sway Brace Attachments .................. 186-187 Sway Brace Main Pipe Attachments ....... 188-190 Concrete Inserts Concrete Deck Inserts .......................................... 192-193 Spot Inserts & Insert Nuts ................................. 194-199 Continuous Concrete Inserts .......................... 200-202 AnchorClips.............................................................................. 203 Brackets LightDuty......................................................................... 206-208 MediumDuty............................................................................. 209 HeavyDuty.................................................................................. 210 Brackets w/ U-Bolts........................................................... 211 Upper Attachments Ceiling Flange.......................................................................... 214 Angle Supports............................................................ 215-218 Swivel Attachment............................................................... 219 Bolted & Welded......................................................... 220-222 Concrete Plates.......................................................... 223-225 Rod Beam Attachments .................................................. 226 Threaded Accessories Eye Sockets & Nuts ................................................. 228-229 U-Bolts................................................................................ 230-232 Miscellaneous Accessories .............................. 233-235 Rods, Couplings, Washers & Hardware .......... 236-247 Vibra TroITM Pads....................................................................................... 251-253 MoldedMounts....................................................................... 253 CupMounts................................................................................ 254 Spring Mounts.............................................................. 255-260 Vibration & Spring Hangers .............................. 261-268 VibraClampTM.................................................................. 269-270 Isolation Products................................................................ 271 DURA-BLOKTM Base.................................................................................................. 274 Base & Channel........................................................... 275-277 Base & Clamp Riser........................................................... 278 Base & Harness........................................................... 279-280 Base & Rollers.............................................................. 281-282 BaseStand.................................................................................. 282 Load Distribution Plate .................................................... 283 KwikWireTM Clamps........................................................................................... 286 r WireRope.................................................................................... 286 KwikPakTM Kits......................................................................... 287 CableCutter.............................................................................. 287 KwikWire Hangers............................................................... 288 Accessories (Loop, Hook, Bracket Termination) ........ 289-293 Reference Data Metric Conversions............................................................. 295 Miscellaneous Charts Piping, Tubing, Threaded Rod, etc.......... 296-306 Trapeze Hanger Chart ........................................... 307-308 MSS & Federal Specifications to B-Line Cross References .............................. 309-310 B-Line Compliances & Approvals ............... 311-312 Cross References Cooper B-Line to TOLCO .............................. 313-314 TOLCO to Cooper B-Line......................................... 315 Anvil/Grinnell to Cooper B-Line/TOLCO ........ 316 Erico to Cooper B-Line/TOLCO ............................. 317 PHD to Cooper B-Line/TOLCO ............................... 318 Super Strut to Cooper B-Line/TOLCO ............. 319 C & P* to Cooper B-Line/TOLCO ............................... 320 Empire to Cooper B-Line/TOLCO ........................ 321 Index........................................................... 322-324 * C & P is Carpenter & Paterson Pipe Hangers & Supports 2 B-Line by E.Z•N .wW l s� Y j1 qm RAW.JWER 4+ :19 WTiT_ Pictorial Index Beam Clamps - 7�1 B351L B3036L B3362 thru B3365 Steel C-Clamp Malleable Iron Retaining Strap B3037 B3031-3/8 With Locknut C-Clamp Page 29 Z-Purlin Beam Clamp Light Duty B3033 Page 28 With Locknut Page 29 Malleable C-Clamp Wide Jaw Page 28 Page 30 Top Flange C-Clamp r Page 30 Nr SO B3034 Fig.68S Fig.65 Fig.65XT-3/8 Fig.66 Fig. Throat) Reversible Reversible Reversible Top Flange (3Steel C-Clamp Steel C-Clamp Steel C-Clamp Page 31 (11/4" Thhroro C-Clamp Fg. With Locknut With Locknut With Locknut Throat) 3 Fig. 67SS /4" Throat 3/4" Throat 11/4" Throat Malleable, Page 33 Page 33 Page 34 (3/4" Throat) Reversible Beam Fig. 68SS Clamps (11/4" Throat) Page 32 AllitReversible }i Stainless Steel Ak— C-Clamp With Locknut Page 35 B303-B309 Beam Clamp Fig. 69 Fig. 69R Page 36 Retaining Strap Retrofit 6321 Series Page 37 Retaining Strap Beam Clamp Page 38 Page 36 B312���� Retaining Strap B3054 Ir Page 39 moo Malleable Iron B3050 B3040 B3055 Beam Clamp Beam Clamp Adjustable Beam Clamp Steel Beam Clamp Page 42 Page 40 Page 40 Page 41 e0l B3291 thru B3298 B3042 B3042T Fig. 130 UFS Forged Steel B3045 Trus Joist Top Beam Clamp Side Beam Clamp Bar Joist Hanger Beam Clamp Page 44 Beam Clamp Page 43 g Page 44 Page 45 Page 46 Pipe Hangers &Supports B-Line 4 by FA-N Pictorial Index Pipe Hangers f Fig. 1 CBS Clevis Pipe Spacer B3B3100C B3100 gWWA 63100E Page 48 Standard B3108 Plastic Coated Clevis Hanger Felt Lined Clevis Hanger Page 51 Extended Standard Pages 49 & 50 Clevis Hanger Clevis Hanger Standard Page 52 Page 53 Clevis Hanger Page 53 f I 1 I B3690 B3690F B3106V B3690C B3109 B3106 Adjustable 'J' Felt Lined Plastic Pipe 1 Plastic Coated Flat Top Clevis Vee Bottom Support Channel Hanger Adjustable anger Adjustable 'J' Hanger Hanger Clevis Hanger p Page 56 Page 54 Page 54 Page 54 Page 55 Page 56Poo 0 B3104 B3104F Light Duty Felt Lined Clevis Hanger Light Duty Page 57 Clevis Hanger Page 57 Fig. 2 Adjustable Band Hanger Page 59 B3104C Plastic Coated B3104CT Light Duty Copper Tubing Clevis Hanger Light Duty Clevis Page 57 Hanger Page 58 B3104CTC Plastic Coated Copper Tubing Light Duty Clevis Hanger Page 58 010 0 B317OCTC Copper Tubing Plastic Coated Adjustable Swivel Ring Page 60 ♦ DURA-COPPER" Finish Ik Available in DURA-GREEN'" Finish (Other hangers may be available with the DURA-GREEN finish, contact factory) B-Line 5 Pipe Hangers & Supports by E.Z•N C) Fig. 2F Felt Lined Adjustable Band Hanger Page 59 B317OCT Copper Tubing Adjustable Swivel Ring Page 60 Pictorial Index Fig.120RWA Fig.120 Retrofit Wrap Around `U' Hanger "u Hanger Clamp Page 68 Page 67 BH-2-4 BH-5-8 BH-9-12 Parallel Strap Hanger Page 71 Pipe Hangers (Continued) Fig. 200 Trimline Adjustable Band Hanger Page 61 Fig. 200F Felt Lined Trimline Adjustable Band Hanger Page 61 �1 Fig. 200C Plastic Coated Trimline Adjustable Band Hanger (I ) Page 61 B3175 Ring and Bolt Hanger Page 65 Fig. 200 H Heavy Duty Band Hanger Page 62 B3198H Hinged Extension Split Pipe Clamp Page 63 B3198HCT Copper Tubing Hinged Extension Split Pipe Clamp B3175CT Copper Tubing Ring and Bolt Hanger Page 65 Page 64 B3190 Offset 'J' Hook Page 66 (111 go--- - Fig. 120MJ Fig. 120W Mutt & Jeff Wrap Around `U' Hanger `U' Hanger Page 69 Page 69 BH-2-4-R BH-5-8-R BH-9-12-R i Right Angle Strap Hanger Page 71 ♦ DURA-COPPER'"" Finish B3198R Extension Split Pipe Clamp Page 63 B3198RCT Copper Tubing Extension Split Pipe Clamp Page 64 B3191 Straight 'J' Hook Page 66 F B3262 Light Duty Spring Hanger Page 70 BL1400 thru 11311-1490 Hanger Page 71 Pipe Hangers &Supports B-Line 6 by FA-N Pictorial Index Pipe Clamps P :2 B3373 Standard Riser Clamp Page 74 B3132 Two -Bolt Underground Clamp Page 76 B3132W Lug Washer Page 76 B3146 Heavy Duty Double Bolt Pipe Clamp Page 85 1�_ B3134 Four -Bolt Underground Clamp Page 77 lb� B3134W Washer Page 77 B314OF Felt Lined Standard Pipe Clamp Pages 79-80 f � r~ u � i Fig. 4113 Pipe Clamp For Sway Bracing Page 86 B3373C Plastic Coated Standard Riser Clamp Page 74 B3373F Felt Lined Standard Riser Clamp Page 74 Fig. 4A Pipe Clamp for Sway Bracing Page 78 B3141 A.W.W.A. Pipe Clamp Page 81 B3148 Offset Pipe Clamp Page 87 B3373CT Copper Tubing Riser Clamp 00=0 Page 75 B3373CTC =90" Copper Tubing Plastic Coated Riser Clamp Page 75 B3140 Standard Pipe Clamp Pages 79-80 a B3142 Heavy Duty Pipe Clamp Page 82 ♦ DURA-COPPER'" Finish B3149 Marine Hanger Page 88 J Ad B3140C Plastic Coated Standard Pipe Clamp Pages 79-80 B3144 Double Bolt Pipe Clamp Pages 83 & 84 B3180FL Flush Mount Pipe Strap Page 89 B-Line 7 Pipe Hangers & Supports by E.Z•N Pictorial Index Pipe Clamps (Continued) t B3180 Extended Leg Pipe Strap Page 90 j. 1 Fig. 24 Double Fastener Side Mounted CPVC Strap Page 96 Fig. 29 Double Offset Hanger & Restrainer for CPVC Pipe Page 101 B2400 Standard Pipe Strap Pages 91-92 Fig. 25 Surge Restrainer Page 97 B3184 Light Duty Offset Hanger & Restrainer for CPVC & IPS Pipe Page 102 Fig.22 Fig.22L2 Fig.23 Single Fastener Sin One Hole Hanger/Restraint g Double Fastener CPVC Strap For CPVC & Steel Pipe CPVC Strap Page 93 g Page 95 r Fig. 28 Fig. 28M `TJ Stand -Off Hanger & Offset Hanger & Fig. 27 Restrainer for Restrainer for Speed Nut CPVC Pipe CPVC & IPS Pipe Page 98 Page 99 Page 100 BPRC Series BPIC Series Rod Mount BPSC Series KWIK-CLIP Channel Mount Page 103 KWIK-CLIP Page104 Pipe Rollers & Roller Supports � 1 Ve B3110 B3114 Adjustable Steel Pipe Roll With Sockets B3122 B3122A Yoke Pipe Roll Page 107 Adjustable Roller Support Adjustable Double Page 106 , Page 108 Roller Guide Page 109 1k Available in DURA-GREEN'" Finish Pipe Hangers &Supports $ B-Line by EA-N Pictorial Index Pipe Rollers & Roller Supports (Continued) B3120 �+!� l Roller Chair '?B3124 1.._ '._ B3126 Page 110 Roller Support g >f' Roller Support a - Page111 Page112 B218 B219 B479 B3117SL Pipe Rollers Pipe Rollers B379 Pipe Rollers Steel Roller Stand Page 113 Page 114 Pipe Rollers Page 115 Page 116 Page 117 .z 0 B3118SL 63119SL Adjustable Roller Stand Roller With Steel B3264 B3114R B3117R With Base Plate Base Plate Spring Cushion Hanger Long Pipe Roll Only Short Pipe Roll Only Page118 Page119 Page120 Page121 Page122 Pipe Supports, Guides, Shields & Saddles B3088T Base Stand B3380 se Stand B3089 Threaded Base Stand ' thru B3384 B3088ST 360' Calcium B3088S Seismic Threaded Pipe Support Pipe Saddle Silicate Shield Seismic Base Stand Base Stand B3096 Adjuster Support Page 124 Pages 125 & 126 Pages 125 & 126 Adjustable Pipe Page 128 With U-Bolt Saddle Support Pages 129 & 130 Page127 1 B3092 B3093 B3097 B3098 B3094 B3095 Adjustable Pipe Saddle Adjustable Pipe Pipe Saddle Adjustable Pipe Flange Support Pipe Saddle Support Support With Yoke Saddle Support With Strap Support w/U-Bolt Page 139 Pages 131 & 132 Pages 133 & 134 Pages 135 & 136 Page 137 Page 138 B-Line 9 Pipe Hangers & Supports by E.Z•N Pictorial Index Pipe Supports, Guides, Shields & Saddles (Continued) B3195 B3281 thru I.P.S. Isolator B3287 B3195CT r Pipe Alignment B3147A Copper Tubing Guide B3147B Isolator Pages Anchor Chairs Page 140 " 141 & 142 Pages 143 & 144 B2417 Pipe Guides -*A_ Page 143 �- B3256 Aik Hold -Down B3257 Anchor Clamp Base Plate B3891 thru B3897 Pipe Slides Page 145 Page 146 Pipe Slides Pages 151 - 154 Pages 147 - 150 B3155 B3151 B3153 B3154 Short Insulation BPH Series Insulation Insulation Protection Short Insulation Protection Shield Snap N'Shield Protection Shield Shield With Tabs Protection Shield With Tabs Clevis Page162 Page162 Page163 Page163 Page164 B3991 thru B3993 TOLCOT" Seismic Bracing AUL Fig. 4B Pipe Clamp For Fig. 4L Fig.4A Sway Bracing Longitudinal "In- Fig. 4LA Page 169 Line" Sway Brace Pipe Clamp For g Attachment Longitudinal "In - Sway Bracing Page 170 Line" Sway Brace Page 168 Attachment r Pages 171 & 172 ,=W Fig. 825A Bar Joist Sway Brace Attachment Page175 Fig. 828 Universal Sway Brace Attachment Page 176 Fig. 906 Sway Brace Multi - Fastener Adaptor Page177 Fig. 800 Adjustable Sway Brace Attachment To Steel Page 173 Fig. 907 4-Way Longitudinal Sway Brace Attachment Page 178 B3160 thru B3165 Pipe Covering Protection Saddle Pages 155 - 160 0 BPS Series Snap N'Shield Pages 165 & 166 Fig. 825 Bar Joist Sway Brace Attachment Page174 Fig. 909 No -Thread Swivel Sway Brace Attachment Page 179 Pipe Hangers &Supports B-Line 10 by EA-N Pictorial Index TOLCOT"' Seismic Bracing (Continued) Fig. 910-''' i Swivel Sway Brace Attachment t ct Fig. 980 Fig. 981 p Page 180 .% Universal Swivel Fast -Attach Fig.975 Sway Brace Universal Swivel Sway Fig. 985 Fig. 986 Attachment Brace Attachment Mechanical Fast Mechanical Fast Straight Sway Page 183 Brace Fitting Page 182 g Clamp Clamp Page181 Page184 Page184 Fig. BRC CABLE Pre -Stretched ! f Aircraft Cable_ E Page 185 " Fig. 990 Fig. 991 Fig. 1000 Fig. 1001 Fig. 2002 Cable Sway Fast Attach Fast Clamp Sway Brace Sway Brace Brace Attachment Cable Sway Brace Sway Brace Attachment Attachment Page 186 Attachment Attachment Page 189 Page 190 Page187 Page188 Concrete Inserts Fig. 109AF Spot Insert Page 194 & B3019 194a _ Fig. 109A Adjustable Metal - Concrete Deck Insert Deck Ceiling Bolt Page 192 & 192a Page 193 B2499 Heavy Duty Spot Insert Page195 N2500 B3014 B3014N B2505thru B2500 Steel Insert Nut Malleable Iron Malleable Iron Insert Nut B2508 Light Duty Spot Insert Page 196 Spot Insert Page 197 Spot Insert Page196 Page197 Page198 BLine 11 Pipe Hangers & Supports by EA-N Pictorial Index Concrete Inserts (Continued) h BE-5-8 B2503 B221, B321, B521 BD40 BE-9-12 Heavy Duty Spot Insert Continuous Concrete Inserts Fastener Clip Fastener Clip Page 199 Pages 200 - 202 Page 203 Page 203 BRACKETS l' A B3068 Light Duty Welded B3064 B3066 B3067 Bracket Adjustable Strut Bracket B3065 Medium Duty Welded Light Duty Welded Bracket Heavy Duty Welded Bracket Page 206 Page 207 Bracket Page 209 Page 210 Page 208 1� r B3069E B3069W " O" Bracket Welded Knee Brace Page 211 Page 211 Upper Attachments ^� B3060L Side Beam �. Angle Clip Page 215 B3199 Ceiling Flange Page 214 B3070 Reversible Angle Clip Page 215 B3199CT Dura-Copper Coated Ceiling Flange Page 214 B3060 Side Beam Angle Clip Page 216 Fig. 78 All Steel Ceiling Plate Page 214 Fig. 50 B3061 Fig. 51 Angle Bracket Side Beam Angle Clip Side Beam Bracket For Page 217 Page 216 NFPA Rod & Fastener Sizing Page 217 ♦ DURA-COPPER"" Finish Pipe Hangers &Supports B-Line 12 by EJ-N Pictorial Index Upper Attachments (Continued) Fig.58 j Fig.75 Threaded Side ` Swivel Attachment Beam Bracket f Page 219 Page 218 f Fig. 56 Tapped Side Beam Connector Page 217 IL B3062 B3083 B3080S (Short) B3058 B3083WO B3080L (Long) Side Beam Connector Side Beam Bracket Structural Welding Lu Page 220 Welded Beam Attachment 9 g Page 220 Page 221 Page 222 44,10110 B3085 B3086 B3084 B3082 Rod Attachment Concrete Plate Clevis Concrete Plate Single Lug Concrete Plate Rod Beam Attachment Page 223 Page 224 Page 225 Page 226 Threaded Accessories B3188C t'; 4 Plastic Coated `A-� Standard U-Bolt Pages 231 & 232 B501 B3188 Light Weight U-Bolt Standard U-Bolt B3200 Page 230 Pages 231 & 232 Weldless Eye Nut Page 229 1 1 B3224 B3203 Hanger Adjuster B3222 Eye Socket B3201 Extension Piece B3223 B3224CT B3202 er Page 228 Forged Steel Clevis Page 234 Page 234 Offset Eye Socket Dura-Co pp Coated Turnbuckle Page 233 g Hanger Adjuster Page 235 ♦ DURA-COPPER" Finish Page 235 B-Line 13 Pipe Hangers & Supports by EA-N Pictorial Index Threaded Accessories (Continued) OOA� B3210 B3205 Eye Rod B3210X Machine Threaded Rod ATR Page 239 Linked Eye Rod Page 236 All Threaded Rod Page 240 Page 236 � j B3214 Tie Bolt Page 238 B3211 1�I Welded Eye Rod 239 B3211X Fig. 98 Linked Welded Eye Rod Rod Stiffener Fig. 98B Page 240 Page 237 Rod Stiffener with x Break Off Bolt Head Page 237 SC228 B3213 Coach Screw Rod Rod Stiffener 000Page 238 �- Page 237 i B655 B3212 "�',' - Steel Rod Coupling J-Bolt - Page 242 Page 241 B656 B3228 DS 16 x 2 Steel Reducer Hex Head Lag Bolt #16 x 2" Rod Coupling ` -Page 242 _ Page 241 Drive Screw Page 241 F- r -' B3220 B200 Malleable Iron Square Washer B3248 Rod Coupling Page 243 Steel Washer Plate HN - Hex Nut Page 243 Page 244 B3234 HHN - Heavy Hex Nut Bevel Washer Page 245 Page 244 AWA FW LW FFW ATB Wedge Anchor Flat Washer Lock Washer Flat Fender Washer Toggle Bolt Page 247 Page 246 Page 246 Page 246 Page 247 Pipe Hangers &Supports B-Line 14 by FA-N Pictorial Index VIBRA TROLTM NNP Ribbed Neoprene Pad Page 251 A NVD Double Deflection Page 253 CNP Cork and Ribbed Neoprene Pad Page 251 CM Metal Housing and Neoprene Page 254 HMLT/HMT Housed 1 " Deflection Mounting Pages 259 & 260 SHE Isolation Spring Hanger Pages 267 & 268 F � r CNNK Cork, Ribbed Neoprene and Steel Page 252 OML/OM Spring Mount Pages 255 & 256 RH Neoprene Hanger Page 266 BVT VibraClamp Tubing Sizes Page 269 BVP VibraClamp Pipe Sizes Page 270 VRP Rubber Cube Pad Page 252 BVS Vibra StripTM for 15/8" Wide B-Line channel Page 253 HSL/HS Vibration Spring Hanger Pages 261 & 262 B1999 Vibra Cushion Page 271 rat:1� J rL HMLE/HME Housed 1 " Deflection Mounting Pages 257 & 258 H ESL/H ES Combination Spring & Neoprene Pages 263 & 264 ISO ISO Pipe Page 271 DU RA-BLOKTM DBP & DBM DB Series AO Bases Base & Short Channel D136 Series D1310 Series Page 274 Page 275 Base & Tall Channel Double Base & Long Channel Page 276 Page 277 B-Line 15 Pipe Hangers & Supports by E.Z•N Pictorial Index DURA-BLOK"' (Continued) DBM Series Base & Clamp Riser Page 278 CLDP10 Load Distribution Plate Page 283 KwikWire"' KwikWire Clamp Page 286 Wire Rope Cutter Page 287 KwikWire Accessories BKL & BKLK Loop Termination Page 290 DBR Series Base & Fixed Height Roller Assembly AO Page 281 60 DB_DS Series I Bases &Harness Assembly 000 4 Pages 279 & 280 DBR Series DBE Series Base & Adjustable Height Base & Adjustable Roller Assembly Height Channel Page 282 Page 282 Wire Rope Page 286 KwikPak'" Kit Page 287 KwikWire Accessories BKH & BKHK Single Hook Termination Page 291 KwikWire Accessories BKYH & BKYHK Double Hook Termination Page 292 KwikWire Hanger Page 288 POO - - =a :- KwikWire Accessories BKA & BKAK Angle Bracket Termination Page 293 Pipe Hangers &Supports B-Line 16 by E.Z•N Strut Systems B-Line's metal framing support system is designed with many time- saving features. Fully adjustable and reusable, with a complete line of channels, fittings, and accessories for multi -purpose applications. i SELECTION CHART for Channels, Materials and Hole Patterns Channel Type Height LLJ Channel Dimensions Width I__I Material Steel 1 & Thickness* Stainless Steel Alum. Type Type 304 316 2 3 4 SH Channel S �� Hole Pattern ** H17/8 TH K06� •• �/� Number Available Finishes: Electro-Galvanized Part Thread Number Size E41�31 NW524 1/4"-20 NW528 3/8"-16 NW525 1/2"-13 Available Finishes: Electro-Galvanized B2000 Series i B2001 Pipe Size 3/8" (10) Ga. 16 B2008 1/2" (15) 16 B2009 3/4" (20) 14 B2010 11. (25) 14 B2011 11/4" (32) 14 B2012 11/2" (40) 12 B2013 2" (50) 12 B2014 21/2" (60) 12 B2015 3" (80) 12 B2016 31/2" (90) 11 B2017 4" (100) 11 B2018 41/2" (115) 11 B2019 5" (125) 11 B2020 6" (150) 11 B2021 7" (175) 11 B2022 8" (200) 11 Available Finishes: Electro-Galvanized, Aluminum, Stainless, DURA-COPPER Painted, Hot -Dip Galvanized and PVC coated. Nut and bolts are included with all two-piece clamps. ** Add "PA" to Part No. for Pre -assembled B-Line by F:'I•N All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 17 Pipe Hangers & Supports Strut Systems Below are some basic clamp and cushions to be used with a strut system. For the industry's most complete line of strut and strut fittings, refer to B-Line's Strut Systems Engineering Catalog. B2000 Series T � B2023 • 1/4" •• • . (6.3) 16 B2024 3/8" (9.5) 16 B2025 1/2" (12.7) 16 B2026 5/8" (15.9) 16 B2027 3/4" (19.0) 16 B2028 7/8" (22.2) 16 B2029 1 " (25.4) 14 B2030 11/8" (28.6) 14 B2031 11/4" (31.7) 14 B2032 13/8" (34.9) 14 B2004 11/2" (38.1) 14 B2011 15/8" (41.3) 14 B2005 13/4" (44.4) 12 B2036 17/8" (47.6) 12 B2037 2" (50.8) 12 B2038 21/8" (54.0) 12 B2039 21/4" (57.1) 12 B2013 23/8" (60.3) 12 B2041 21/2" (63.5) 12 B2042 25/8" (66.7) 12 B2043 23/4" (69.8) 12 B2014 27/8" (73.0) B2045 3" (76.2) fl B2046 31/8" (79.4) B2047 31/4" (82.5) 12 B2048 33/8" (85.7) 12 B2015 31/2" (88.9) 12 B2050 35/8" (92.1) 11 B2051 33/4" (95.2) 11 B2016 4" (101.6) 11 B2054 41/8" (104.8) 11 B2055 41/4" (107.9) 11 B2056 43/8" (111.1) 11 B2017 41/2" (114.3) 11 B2058 45/8" (117.5) 11 B2059 43/4" (120.6) 11 B2060 47/8" (123.8) 11 B2061 5" (127.0) 11 B2062 51/8" (130.2) 11 B2063 51/4" (133.3) 11 B2064 53/8" (136.5) 11 B2065 51/2" (139.7) 11 BVT & BVP Series Vibra-Clamp'" CopperFor OD Sizes Catalog BVT025 Copper •. Tubing Size 1/4" (6.3) Copper -- -- BVT037 3/8" (9.5) 1/4" (6) BVT050 1/2" (12.7) 3/8" (10) BVT062 5/8" (15.9) 1/2" (15) BVT075 3/4" (19.0) 5/8" (17) BVT087 7/8" (22.2) 3/4" (20) BVT100 1 " (25.4) -- -- BVT112 11/8" (28.6) 1 " (25) BVT125 11/4" (31.7) -- -- BVT137 13/8" (34.9) 11/4" (32) BVT150 11/2" (38.1) -- -- BVT162 15/8" (41.3) 1112" (40) BVT175 13/4" (44.4) -- -- BVT187 17/8" (47.6) -- -- BVT200 2" (50.8) -- -- BVT212 21/8" (54.0) 2" (50) BVT225 21/4" (57.1) -- -- BVT250 21/2" (63.5) -- -- BVT262 25/8" (66.7) 21/2" (65) BVT300 3" (76.2) -- -- BVT312 31/8" (79.4) 3" (80) BVT362 35/8" (92.1) 31/2" (90) BVT400 4" (101.6) -- -- BVT412 41/8" (104.8) 4" (100) BVT612 61/8" (155.6) 6" (150) Available for tubing and pipe sizes 1/4" to 6", OD sizes 1/4" to 65/811. Easy one tool installation, dampens vibration and noise, secures tubing firmly, and protects against galvanic reaction. Stainless Steel available B1999 Vibra-CushionT" • Inhibits Galvanic Reaction 0 • Reduces Sound & Vibration • Used on refrigeration, HVAC, copper tubing, glass pipes & hydraulic lines o Available in 20 Ft. rolls. in For . Nominal Size 3/8" (10) • Conduit or Length of Vibra-Cushion 21/8" (54.0) • Use Clamp No. B2002 1/2" (15) 25/8" (66.7) B2009 3/4" (20) 31/4" (82.5) B2031 111 (25) 41/8" (104.8) B2004 11/4" (32) 53/16" (131.8) B2012 11/2" 40 515/16" 150.8 B2038 2" 50 71/2" 190.5 B2042 21/2" 65 9" 228.E B2046 3" (80) 1111 (279.4) 132051 31/2" 90 121/2" 317.5 B2055 4" (100) 141/2" (368.3) B2059 5" (125) 177/16" (442.9) B2067 6" (150) 203/4" (527.0) I B2116 For Thinwall (EMT) Conduit Nominal Size 3/8" (10) Length Vibra-Cushion 113/16" of (46.0) Use Clamp No. B2027 1/2" (15) 23/16" (58.7) B2002 3/4" (20) 27/8" (73.0) B2003 1 " (25) 35/8" (92.1) B2032 11/4" (32) 43/8" (120.6) B2036 11/2" (40) 57/16" (138.1) B2012 2" (50) 1 67/8" 1 (174.6)1 B2013 CopperFor Nominal Size 1/4" (6) Length of Vibra-Cushion 13/16" (30.2) Use Clamp No. B2026 3/8" (10) 19/16" (39.7) B2027 1/2" (15) 17/8" (47.6) B2028 5/8" (17) 25/16" (58.7) B2029 3/4" (20) 23/4" (69.8) B2030 1 " (25) 31/2" (88.9) B2032 11/4" (32) 45/16" (109.5) B2011 11/2" (40) 51/8" (130.2) B2036 2" (50) 611/16" (169.9) B2013 21/2" (65) 81/4" (209.5) B2014 3" (80) 913/16" (249.2) B2048 31/2" (90) 113/8" (288.9) B2052 4" (100) 1215/16" (328.6) B2056 5" (125) 61/8" (409.6) B2064 6" (150) 191/4" (488.9) B2112 8" poo) 251/2" (647.7) B2128 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers & Supports 18 B-Line by FA-N Technical Data MATERIALS Carbon Steel Carbon steel is used in the manufacture of B-Line pipe hangers and supports. Excellent strength characteristics and adaptability to cold forming provide a well engineered design. By cold forming the steel, mechanical properties are increased, adding to the structural integrity of the fabricated hanger. Stainless Steel AISI Type 304 and Type 316 are non-magnetic members of the austenitic stainless steel group. Several conditions make the use of stainless steel ideal. These include reducing long term maintenance costs, high ambient temperatures, appearance, and stable structural properties such as yield strength, and high creep resistance. CORROSION All metal surfaces exposed to the environment are affected by corrosion. Depending on the physical properties of the metal and its proximity to other dissimilar metals, an electrochemical reaction may occur which causes an attack on the metal itself, resulting in corrosion. Chemical corrosion is limited to highly corrosive environments, high temperatures, or a combination of both. FINISHES Zinc Coatings Protective zinc coatings are available on a number of pipe hangers and accessories in three basic forms: Electro-galvanized, pre -galvanized, and hot -dip galvanized after fabrication. In all cases, the zinc protects the steel first as a sacrificial anode to repair bare areas on cut edges and gouges. When exposed to air and moisture, zinc forms a tough, adherent protective film consisting of a mixture of zinc oxides, hydroxides, and carbonates. The corrosion resistance of zinc is directly related to its thickness and the environment. For example a 0.2 mil (5 µm) coating will last twice as long as a 0.1 mil (2.5 µm) coating in the same environment. Electro-Galvanized (ASTM B633 SC1 or SC3) An electro-galvanized process deposits a coating of zinc on the steel by electrolysis from a bath of zinc salts. This coating is pure zinc and adheres to the steel with a molecular bond. A maximum of 0.5 mils (12.7 µm) of zinc can be applied by this method. This coating is recommended for in -door use in relatively dry areas. Pre -Galvanized Zinc (ASTM A653 Coating Designation G90) Pre -galvanized zinc is produced by continuously rolling the steel coils or sheets through molten zinc at the steel mills. This is also known as "mill - galvanized" or "hot -dipped mill galva- nized". Coils are then slit to size for fabrication of pipe hangers. Coating thicknesses of G90, is 0.90 ounces per square foot (0.27 kg/m2) of steel surface. Zn ZnFe l Fe fZno Protection of cut edges with zinc coatings. Cut edges and welded areas are not zinc coated; however, zinc near the uncoated metal becomes a sacrificial anode which protects the bare areas after a short period of time. Pre -galvanized steel is not generally recommended for use outdoors in industrial environments, but is suitable for extended exposure in dry or mildly corrosive atmospheres. Hot -Dip Galvanized After Fabrication (ASTM A123) After a pipe hanger or fitting has been fabricated, it is completely immersed in a bath of molten zinc. A metallurgical bond is formed, resulting in a zinc coating that completely coats all surfaces, including edges. Zinc coatings of this specification have a minimum thickness of 1.50 ounces per square foot (0.45 kg/m2) on each side or a total of 3.0 ounces per square foot (0.9 kg/m2) of steel. Hot -dip galvanized after fabrication is recommended for outdoor exposure. For best results, a zinc rich paint (available from B-Line) should be applied to field cuts. The zinc rich paint will provide immediate protection for field cuts and eliminate the short time period for galvanic action to "heal" the damaged coating. Plastic Coating Some products offered by B-Line are plastic or vinyl coated for prevention of galvanic reaction between materials or for noise reduction. These coated products can also be used where contact between glass pipe and hanger is not desirable. Felt lined hangers may be substituted for same purpose. Red Primer A corrosion resistant metal primer containing rust inhibitive pigments. B-Line 19 Pipe Hangers & Supports by E.Z•N Technical Data DURA-COPPERTm and DURA-GREENTM Epoxy Coatings DURA-COPPER and DURA-GREEN are water borne epoxy coatings applied to B-Line products by a precisely controlled cathodic electro- deposition process. This process is accomplished using a conveyor to transport parts through several cleaning, phosphatizing and application stages prior to being baked (See diagram below). This custom designed paint system is used for painting all copper painted hanger parts and all green channel, slotted angle and fittings. Samples are selected on a routine basis for Salt Spray (fog) testing to verify the quality of the finish. These tests are performed in accordance with ASTM 13117-73 and evaluated and rated according to ASTM D1654-79 (Tables 1 & 2). The DURA-COPPER and DURA-GREEN Epoxy coatings have been tested and listed by Underwriters Laboratories in accordance with "Standard for Pipe Hanger Equipment for Fire Protection Service, UL 203" and meet or exceed all requirements of Federal Specification TT-C-49013 Paragraph 3. DURA-COPPERTM & DURA-GREENTM EPDXY COATING PROCESS Quality Assurance B-Line's Quality Assurance Program has been developed and implemented for compliance to various industry standards and specifications. TANK 1 TANK 2 TANK 3 TANK 4 TANK 5 TANK 6 TANK 7 TANK 8 BAKE OVEN Parts are Rinse is Phosphatized The material Deionized rinse The electro- The first The final rinse The curing thoroughly applied to sealer is applied moves through prepares the coating tank post rinse insures a process takes cleaned and remove to insure clear water metal for the applies a removes any smooth, 20 minutes at a phosphatized. insoluble salts corrosion resis- rinse to remove cathodic uniform coat of unelectrically nonblemish baking and unreacted tance and paint excess phos- electro-coating. epoxy paint to attracted finish. temperature of phosphates. adhesion. phates. the entire solids. 375°F (199°C). surface. LJLJL�jL.LjLik SALT SPRAY TEST RESULTS DURA-COPPER DURA-COPPER out performs Epoxy Copper Plating 4 to 1 Copper Plating Elapsed Time (1) All salt spray (fog) tests conducted in accordance with ASTM 13117-73 and evaluated and rated according to ASTM D1654-79 Tables 1 & 2. Tests were performed and certified by an independent testing laboratory. General Information Torque The torque values in this catalog are to be used as a guide only. The relationship between the applied torque or torque wrench reading and the actual tension created in the bolt may be substantially different. Important factors affecting torque -tension relationships include friction under the bolt head or nut, hole tolerances, and torque wrench tolerances. Accuracy of many commercial torque wrenches may vary as much as plus or minus 25%. Charts and Tables Charts and tables in this section are compiled from information published by nationally recognized organizations and are intended for use as a guide only. B-Line recommends that users of this information determine the validity of such information as applied to their own applications. Eaton's B-Line reserves the right to make specification changes without notice. Pipe Hangers & Supports 20 B-Line by EA-N Technical Data SECTION 15140 - PIPE HANGERS AND SUPPORTS Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the pipe hanger and supports as described in this specification. 1.02 REFERENCES A. ASTM B633 - Specification for Electrodeposited Coatings of Zinc on Iron and Steel. B. ASTM A123 - Specification for Zinc (Hot -Dip Galvanized) Coatings on Iron and Steel Products. C. ASTM A653 - Specification for Steel Sheet, Zinc -Coated (Galvanized) or Zinc -Iron Alloy -Coated (Galvannealed) by the Hot -Dip Process. D. ASTM A1011 - Specification for Steel, Sheet and Strip, Hot -Rolled, Carbon, Structural, High -Strength Low -Alloy, and High -Strength Low -Alloy with Improved Formability. E. ANSI/MSS SP-58 - Manufacturers Standardization Society: Pipe Hangers and Supports - Materials, Design, and Manufacture. F. ANSI/MSS SP-69 - Manufacturers Standardization Society: Pipe Hangers and Supports - Selection and Application. G. NFPA 13 - Installation of Sprinkler Systems. 1.03 QUALITY ASSURANCE A. Hangers and supports used in fire protection piping systems shall be listed and labeled by Underwriters Laboratories. B. Steel pipe hangers and supports shall have the manufacturers name, part number, and applicable size stamped in the part itself for identification. C. Hangers and supports shall be designed and manufactured in conformance with ANSI/MSS SP-58. D. Supports for sprinkler piping shall be in conformance with NFPA 13. 1.04 SUBMITTALS A. Submit product data on all hanger and support devices, including shields and attachment methods. Product data to include, but not limited to materials, finishes, approvals, load ratings, and dimensional information. Part II - PRODUCTS 2.01 ACCEPTABLE MANUFACTURERS A. Manufacturer: Subject to compliance with these specifications, pipe hanger and support systems shall be as manufactured by B-Line, Inc. 2.02 PIPE HANGERS AND SUPPORTS A. Hangers 1. Uninsulated pipes 2 inch and smaller: a. Adjustable steel swivel ring (band type) hanger, B-Line Fig. 200. b. Adjustable steel swivel J-hanger, B-Line 63690. c. Malleable iron ring hanger, B-Line B3198R or hinged ring hanger, B3198H. d. Adjustable steel clevis hanger, B-Line B3104 or B3100. B Llne 21 Pipe Hangers & Supports by F.T-N Technical Data 2. Uninsulated pipes 21/2 inch and larger: a. Adjustable steel clevis hanger, B-Line B3100. b. Pipe roll with sockets, B-Line B3114. c. Adjustable steel yoke pipe roll, B-Line B3110. 3. Insulated pipe - Hot or steam piping: a. 2 inch and smaller pipes: use adjustable steel clevis with galvanized sheet metal shield, B-Line B3100 with B3151 or B3153 series. b. 21/2 inch and larger pipes: i. Adjustable steel yoke pipe roll with pipe covering protection saddle, B-Line B3110 with B3160 - B3165 series. ii. Pipe roll with sockets with pipe covering protection saddle, B-Line B3114 with B3160 - B3165 series. 4. Insulated pipe - Cold or chilled water piping: a. 5 inch and smaller pipes: use adjustable steel clevis with galvanized sheet metal shield, B-Line B3100 with B3151 or B3153 series. b. 6 inch and larger pipes: i. Adjustable steel yoke pipe, B-Line B3110, with B3380CW - B3384CW calcium silicate shield. ii. Pipe roll with sockets, B-Line B3114, with B3380CW - B3384CW calcium silicate shield. B. PIPE CLAMPS 1. When flexibility in the hanger assembly is required due to horizontal movement, use pipe clamps with weldless eye nuts, B-Line B3140 or B3142 with B3200. For insulated lines use double bolted pipe clamps, B-Line B3144 or B3146 with B3200. C. MULTIPLE OR TRAPEZE HANGERS 1. Trapeze hangers shall be constructed from 12 gauge roll formed ASTM A1011 SS Gr. 33 structural steel channel, 15/8" x 15/8" minimum, B-Line B22 strut or stronger as required. 2. Mount pipes to trapeze with two piece pipe straps sized for outside diameter of pipe, B-Line B2000 series. 3. For pipes subjected to axial movement: a. Strut mounted roller support, B-Line B3126. Use pipe protection shield or saddles on insulated lines. b. Strut mounted pipe guide, B-Line B2417. D. WALL SUPPORTS 1. Pipes 4 inch and smaller: a. Carbon steel hook, B-Line B3191. b. Carbon steel J-hanger, B-Line B3690. 2. Pipes larger than 4 inch: a. Welded strut bracket and pipe straps, B-Line B3064 and B2000 series. b. Welded steel brackets, B-Line B3066 or B3067, with roller chair or adjustable steel yoke pipe roll. B-Line B3120 or B3110. Use pipe protection shield or saddles on insulated lines. Pipe Hangers & Supports 22 B-Line by EA-N Technical Data E. FLOOR SUPPORTS 1. Hot piping under 6 inch and all cold piping: a. Carbon steel adjustable pipe saddle and nipple attached to steel base stand sized for pipe elevation, B-Line B3093 and B3088T or B3090 and B3088. Pipe saddle shall be screwed or welded to appropriate base stand. 2. Hot piping 6 inch and larger: a. (Adjustable) Roller stand with base plate, B-Line B3117SL (or B3118SL). b. Adjustable roller support and steel support sized for elevation, B-Line B3124 F. VERTICAL SUPPORTS 1. Steel riser clamp sized to fit outside diameter of pipe, B-Line B3373. G. COPPER TUBING SUPPORTS 0 1. Hangers shall be sized to fit copper tubing outside diameters. 0 v a. Adjustable steel swivel ring (band type) hanger, B-Line B3170CT. d b. Malleable iron ring hanger, B-Line B3198CT or hinged ring hanger B3198HCT. c. Adjustable steel clevis hanger, B-Line B3104CT. H. PLASTIC PIPE SUPPORTS 1. V-bottom clevis hanger with galvanized 18 gauge continuous support channel, B-Line B3106 and B3106V, to form a continuous support system for plastic pipe or flexible tubing. I. SUPPLEMENTARY STRUCTURAL SUPPORTS 1. Design and fabricate supports using structural quality steel bolted framing materials as manufactured by B-Line. Channels shall be roll formed, 12 gauge ASTM A1011 SS Grade 33 steel, 15/8" x 15/8" or greater as required by loading conditions. Submit designs for pipe tunnels, pipe galleries, etc., to engineer for approval. Use clamps and fittings designed for use with the strut system. 2.04 UPPER ATTACHMENTS A. BEAM CLAMPS 1. Beam clamps shall be used where piping is to be suspended from building steel. Clamp type shall be selected on the basis of load to be supported, and load configuration. 2. C-Clamps shall have locknuts and cup point set screws, B-Line B351 L, B3036L or Fig. 65XT Top flange C-clamps shall be used when attaching a hanger rod to the top flange of structural shapes, B-Line B3034 or B3033. Refer to manufacturers' recommendation for setscrew torque. Retaining straps shall be used to maintain the clamp's position on the beam where required (Fig. 69, Fig. 69R). 3. Center loaded beam clamps shall be used where specified. Steel clamps shall be B-Line B3050 or B3055. Malleable iron or forged steel beam clamps with cross bolt shall be B-Line B3054 or B3291 - B3297 series as required to fit beams. B. CONCRETE INSERTS 1. Cast in place spot concrete inserts shall be used where applicable, either steel or malleable iron body, B-Line B2500 or B3014. Spot inserts shall allow for lateral adjustment and have means for attachment to forms. Select insert nuts to suit threaded hanger rod sizes, B-Line N2500 or B3014N series. B-Line 23 Pipe Hangers & Supports by E.Z•N Technical Data 2. Continuous concrete inserts shall be used where applicable. Channels shall be 12 gauge, ASTM A 1011 SS Grade 33 structural quality carbon steel, complete with styrofoam inserts and end caps with nail holes for attachment to forms. The continuous concrete insert shall have a load rating of 2,000 Ibs/ft. in concrete, B-Line B221, B321, or B521 (B521 is limited to 1,500 Ibs/ft.). Select channel nuts suitable for strut and rod sizes. 2.05 VIBRATION ISOLATION AND SUPPORTS A. For refrigeration, air conditioning, hydraulic, pneumatic, and other vibrating system applications, use a clamp that has a vibration dampening insert and a nylon inserted locknut. For copper and steel tubing use B-Line BVT series VibraClamps, for pipe sizes use BVP series. B. For larger tubing or piping subjected to vibration, use neoprene or spring hangers B as required. 0 m C. For base mounted equipment use vibration pads, molded neoprene mounts, or spring t mounts as required. D. Vibration isolation products as manufactured by B-Line, VibraTrol systems. 2.06 ACCESSORIES A. Hanger rods shall be threaded both ends, B-Line B3205, or continuous threaded rods of circular cross section. Use adjusting locknuts at upper attachments and hangers. No wire, chain, or perforated straps are allowed. B. Shields shall be 180' galvanized sheet metal, 12 inch minimum length, 18 gauge minimum thickness, designed to match outside diameter of the insulated pipe, B-Line B3151. C. Pipe protection saddles shall be formed from carbon steel, 1/8 inch minimum thickness, sized for insulation thickness. Saddles for pipe sizes greater than 12 inch shall have a center support rib. 2.07 FINISHES INDOOR FINISHES A. Hangers and clamps for support of bare copper piping shall be coated with copper colored epoxy paint, B-Line DURA-COPPER'". Additionally a plastic coating or a felt lining in hanger can be used. B. Hangers for other than bare copper pipe shall be zinc plated in accordance with ASTM B633 - SC3 or shall have an electro-deposited green epoxy finish, B-Line DURA-GREEN". C. Strut channels shall be pre -galvanized in accordance with ASTM A653 G90 or have an electro-deposited green epoxy finish, B-Line DURA-GREEN. OUTDOOR AND CORROSIVE AREA FINISHES D. Hangers and strut located outdoors shall be hot dip galvanized after fabrication in accordance with ASTM A123. All hanger hardware shall be hot -dip galvanized or stainless steel. Zinc plated hardware is not acceptable for outdoor or corrosive use. E. Hangers and strut located in corrosive areas shall be Type 304 (316) stainless steel with stainless steel hardware. Pipe Hangers & Supports 24 B-Line by EA-N Technical Data Part III - EXECUTION 3.01 PIPE HANGERS AND SUPPORTS A. Pipe shall be adequately supported by pipe hanger and supports specified in PART II - PRODUCTS. Hangers for insulated pipes shall be sized to accommodate insulation thickness. B. Horizontal steel piping shall be supported in accordance with ANSI/MSS SP-69 & SP-58 Tables 3 and 4, excerpts of which follow below: NOMINAL PIPE SIZE ROD DIAMETER MAXIMUM SPACING 3/8" - 11/4" 3/8„ 7'-0„ 11/2" 3/8„ 91-01, 2" 3/8" 10'-0" S 21/2" 1/2" 11'-0" d 0 3" 1 /2" 12'-0" d iv 31 /2" 1 /2" 13'-0" 4" 5/8" 14'-0" 5" 5/8" 16'-0" 6" 3/4" 17'-0" 8" 3/4" 19'-0" 10" 7/8" 22'-0" 12" 7/8" 23'-0" 14" ill 25'-0" 16" ill 27'-0" C. Horizontal copper tubing shall be supported in accordance with ANSI/MSS SP-69 & SP-58 Tables 3 and 4, excerpts of which follow below: NOMINAL TUBING SIZE ROD DIAMETER MAXIMUM SPACING 1/4" - 3/4" 3/8„ 5,-0„ ill 3/8„ 6,-0„ 11/4" 3/8„ 7'-O„ 11/2" 3/8„ 8,-0„ 2" 3/8„ 8,-0„ 21/2" 112" 9'-0" 3" 1/2" 10'-0" 31/2" 1/2" 11'-0" 4" 1 /2" 12'-0" 5" 1/2" 13'-0" 6" 5/8" 14'-0" 8" 3/4" 16'-0" D. Provide means of preventing dissimilar metal contact such as plastic coated hangers, copper colored B-Line DURA-COPPER" epoxy paint, or non -adhesive isolation tape (B-Line Iso-Piper"). Galvanized felt isolators sized for copper tubing may also be used, B-Line B3195CT. B-Line 25 Pipe Hangers & Supports by E.Z•N Technical Data E. Support horizontal cast iron pipe adjacent to each hub, with 10 feet maximum spacing between hangers. F. Install hangers to provide a minimum of 1/2 inch space between finished covering and adjacent work. G. Place a hanger within 12 inches of each horizontal elbow. H. Support vertical piping independently of connected horizontal piping. Support vertical pipes at every (other) floor. Wherever possible, locate riser clamps directly below pipe couplings or shear lugs. I. Where several pipes can be installed in parallel and at the same elevation, provide trapeze hangers as specified in Section 2.02 C. Trapeze hangers shall be spaced according to the smallest pipe size, or install intermediate supports according to schedule in Section 3.01 B. o m J. Do not support piping from other pipes, ductwork or other equipment which is not building structure. 3.02 CONCRETE INSERTS A. Provide inserts for placement in formwork before concrete is poured. B. Provide inserts for suspending hangers from reinforced concrete slabs and sides of reinforced concrete beams. C. Where concrete slabs form finished ceilings, provide inserts to be flush with slab surface. D. For inserts carrying 5" nominal pipe and larger, provide hooked rod to concrete reinforcement. Pipe Hangers &Supports B-Line 26 by EA-N Beam Clamps Beam clamps offered in this section are designed to provide attachment of hanger rods to structural members without drilling or welding. A wide range of types and sizes are available for various applications. Materials Carbon Steel, Malleable Iron and Forged Steel are used in the manufacturing of beam clamps and accessories. Stainless steel and other materials are available. Finishes The standard finishes for mechanical supports are plain steel (oil coated) sometimes referred to as black and Electro- Galvanized Zinc (ASTM B633 SC3). Hot -Dip Galvanized After Fabrication (ASTM A123), Red Primer, Plastic Coating and DURA-GREENT". Other special coatings are available upon request. Note: Due to the design of some products, (threads, connecting hardware, swivels, etc.) items may or may not be uniformly coated with special finishes. In some cases, the hanger itself may be coated, however, the hardware may be supplied Electro-Plated, copper plated, or in stainless steel. Recommended Set screw Torque (unless otherwise specified) 1/4"-20 3/8"-16 1/2"-13 5/8"-11 3/4"-1 O 4 ft/Ibs (5 Nm) 5 ft/Ibs (7 Nm) 11 ft/Ibs (15 Nm) 21 ft/Ibs (28 Nm) 34 ft/Ibs (46 Nm) Over torqued set screws will damage beam clamps in this section. We are aware that torque wrenches are not used or not available in many instances. In the absence of a torque wrench, the set screw should be finger tightened to the I-beam and then an additional 1/4 to 1/2 turn applied to the set screw. Approvals (as noted) Items in this section are Underwriters Laboratories Listed, Factory Mutual Approved, and comply with Federal Specification WW-H-171 E & A-A-1192A or Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. by -Line by E:T-N 27 Pipe Hangers & Supports Beam Clamps B351 L - Steel C-Clamp With Locknut (TOLCO Fig. 64) Size Range: 3/8"-16 thru 7/8"-9 rod Material: Steel Function: For attachment to I -beams, channels, and wide flange beams where the thickness does not exceed 3/4" (1g.omm). Hardened set screw secures "C" Clamp to beam. Approvals: B351 L (3/8"-16 - 3/4"-10), is Underwriters Laboratories Listed. Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 23 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 23. Finish: Plain. Contact B-Line for alternative finishes and materials. Note: When retaining strap is required, order B3362 thru B3365 separately. See page 29. Order By: Part number and finish B3O36L - Malleable Iron C-Clamp With Locknut c &us LISTED D B f: c Set Screw and Locknut Included A (Rod Size) Hanger Rod Not Included Size Range: 3/8"-16 thru 3/4"-10 rod ce us Material: Malleable Iron LISTED Set Screw and 9/4" Function: Designed for attaching a hanger rod to the flange of a beam. Locknut Included (ts.o) Approvals: B3036L is Underwriters Laboratories Listed. Complies A with Federal Specification WW-H-171 E & A-A-1192A Type 23 and (Rod size) B Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58 Type 23. Hanger Rod Finish: Plain or Electro-Galvanized Not Included Order By: Part number and finish. When retaining strap is required, order B3362 thru B3365 separately. See page 29. Note: See page 27 for recommended setscrew torque. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 28 B-Line by Ect•N Beam Clamps 133362, 133363, 133364, B3365 - Retaining Strap Size Range: 6" (152.4mm) to 12" (304.8mm) lengths Material: Steel (Stainless Steel available) Finish: Pre -Galvanized Function: Designed for use with B351 L and B3036L C-Clamps. Order By: Part number, length 'L', (add 1 " (25.4) minimum to flange width), and finish. Note: Requires field forming on beam. B3037 - Z-Purlin Malleable C-Clamp Material: Malleable Iron Function: Designed for attaching a 3/8"-16 hanger rod to the bottom flange of a Z-purlin. Approvals: Underwriters Laboratories Listed for up to 4" (loomm) pipe. Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 23 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 23. Finish: Plain or Electro-Galvanized Order By: Part number and finish. Weight: Approx. Wt./100 90 Lbs. (40.8kg) Design Load: 400 Lbs. (1.78kN) Note: See page 27 for recommended setscrew torque. C &us LISTED 3" (76.2) Throat Opening 31/32" (24.6) Bottom Hanger Rod Threads 3/s"-16 Material Thickness 12 Gauge (2.7) 313/3211 (86.5) Set Screw and Locknut Included B-Line by E:T-N All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 29 Pipe Hangers & Supports Beam Clamps B3031-3/8 - Light Duty Malleable C-Clamp Material: Malleable Iron Function: Designed for attaching a 3/8"-16 hanger rod to the top or 11/2" bottom flange of a beam or bar joist when setscrew is in the down position (38.1) as shown. Approvals: Underwriters Laboratories Listed for up to 4" pipe. Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 19 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 19. Finish: Plain or Electro-Galvanized Order By: Part number and finish. When retaining strap is required, order Fig. 69 separately. See Page 37. Weight: Approx. Wt./100 25 Lbs. (11.3kg) Design Load: 350 Lbs. (1.55kN) Note: See page 27 for recommended setscrew torque. B3O33 - Wide Jaw Reversible C-Clamp (TOLCO Fig. 68) Size Range: 3/8"-16 thru 3/4"-10 rod 3/4" (19.0) c @us (47.5) LISTED Throat Opening .� 11/16" (17.5) Material: Cast Malleable Steel with hardened cup point set screw and jam nut Function: For attachment to structural shapes requiring wider throat Throat Opening especially under roof with bar joist construction. 11/4" (31.7) for B3033-3/8 & 1h This clamp may be used with the set screw in the up or down position. 15/15" (33.3) for B3033-5/8 & 3/4 Approvals: Underwriters Laboratories Listed (cULus) and Factory Mutual Engineering Approved (FM). Conforms to Federal Specification WW-H-171 E Type 19 & A-A-1192A, Type 19 & 23 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 19 & 23. rY Finish: Plain. Contact B-Line for alternative finishes and - materials. Order By: Part number, rod size and finish - Note: Do not over tighten set screw. "'•� Top Flange Attachment Applications Note: See page 27 for recommended setscrew torque. Hanger Rod Set Screw and Not Included Locknutlncluded C O B sue — Set Screw and Locknutlncluded C&S <FM> LISTED°°--D Bottom Flange Attachment Applications A (Rod Size) Hanger Rod Not Included All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 30 B-Line by Ect•N Beam Clamps B3034 - C-Clamp Size Range: 3/8"-16 thru 3/4"-10 rod Material: Cast Malleable Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (19.0mm). Features: May be used on top or bottom flange of the beam. Beveled lip allows hanging from top flange where clearance is limited. may be installed with the set screw in the up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. The rear window design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed and Factory Mutual Engineering Approved for 3/8"-16 and 1/2"-13 rod sizes. Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 19 & 23 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 19 & 23. 3/8"-16 is (cULus) Listed to support up to 4" (100mm) pipe with the set screw in the down position, up to 3" (75mm) pipe with the set screw in the up position. 1/2"-13 is (cULus) Listed to support up to 8" (200mm) pipe with the set screw in the down position, up to 6" (150mm) pipe with the set screw in the up position. Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number and finish B3034-5/8" and B3034-3/4" sizes Attach only as shown. C DD � Throat Opening 3/4" (19.0) A (Rod Size) Hanger Rod W' = Not Included Set Screw and Locknutlncluded Note: See page 27 for recommended setscrew torque. ells LISTED FM � Throat Opening 3/4" (19.0) 133034-3/8" and B3034-1/2" sizes Attach only as shown. C Set Screw and Locknutlncluded Top Flange Attachment Applications Bottom Flange Attachment Applications A (Rod Size) Hanger Rod Not Included B-Line by E:TlN All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 31 Pipe Hangers & Supports Beam Clamps Fig. 68S - Reversible Malleable Beam Clamp 3/41' (19.omm) Throat Opening Fig. 68W - Reversible Malleable Beam Clamp 11/4" (31.7mm) Throat Opening (bottom of page) Size Range: (g)TDLCC3 3/8"-16 rod sizes thru 7/8"-9 rod sizes FM Material: Cast Malleable Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (19.omm) on Fig. 68S or 11/4" (31.7mm) on Fig.68W. Features: May be used on top or bottom flange of beam. Beveled lip allows hanging from top flange where clearance is limited. May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. The rear window design permits inspection of thread engagement. Approvals: Factory Mutual Engineering Approved. Underwriters Laboratories Listed. Conforms to Federal Specification WW-H-171 E, Type 23 and Manufacturers Standardization Society SP-58, Type 19. Fig. 68S-3/8 is cULus Listed to support up to 4" (100mm) pipe with the set screw in the down position and up to 3" (80mm) pipe with the set screw in the up position. Fig. 68S-1/2 is cULus Listed to support up to 8" (200mm) pipe with the set screw in the down position and up to 6" (150mm) pipe with the set screw in the up position. Fig. 68W-3/8 is cULus Listed to support up to 4" (100mm) pipe with the set screw in the down position and up to 4" (loomm) pipe with the set screw in the up position. Fig. 68W-1/2 is cULus Listed to support up to 6" (150mm) pipe with the set screw in the down position and up to 6" (15omm) pipe with the set screw in the up position. Factory Mutual Engineering approved only with the set screw in the down position. (OSHPD). For additional load spacing and placement information relating OSHPD projects, please refer to the Seismic Restraint System Guidelines. Finish: Plain. Contact B-Line for Electro-Galvanized or HDG finishes. Order By: Part number and finish Fig. 68S Fig. 68W . a + + aw Fig. 68S A (Rod' Hange Not Inc c &GIs LISTED Fig. 68S Set Screw and Locknutlncluded D = Depth of Throat A (Rod Size) G• Hanger Rod w Not Included Fig. 68W Set Screw and Locknutlncluded Part i 68S-% 'ii 3/8"-16 Size 19/16" B (39.7) Min. 3/4" C (19.0) 11/8" 1 (28.6) 7/16" E (11.1) F 7/8" (22.2) Max Rec. Set Screw 610 Load Up (2.71) Max Rec. Set Screw 610 Load li (2.71) Approx. II 32 (14.5) 68S-1/2 1/2"-13 15/8" (41.3) 3/4" (19.0) 1" (25.4) 7/16" (11.1) 11/8" (28.6) 750 (3.33) 1130 (5.02) 54 (24.5) 68S-5/8 5/8"-11 19/16" (39.7) 3/4" (19.0) 1" (25.4) 9/16" (14.3) 11/8" (28.6) 750 (3.33) 1130 (5.02) 50 (22.7) 68S-3/4 3/4"-10 13/4" (44.4) 3/4" (19.0) 11/8" (28.6) 9/16" (14.3) 11/4" (31.7) 750 (3.33) 1130 (5.02) 81 (36.7) 68S-7/8 7/8"-9 1 13/4" (44.4) 1 3/41, (19.0) 1 11/81, (28.6) 9/16" (14.3) 15/16" (33.3) 1 750 (3.33) 1 1130 (5.02) 1 75 (34.0) Fig. 68W Note: See page 27 for recommended setscrew torque. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 32 B-Line by IFA-N Beam Clamps Fig. 65 - Reversible Steel C-Type Beam Clamp 3/411 (19.omm) Throat Opening Fig. 65XT - Reversible Steel C-Type Beam Clamp 3/41, (19.omm) Throat Opening (bottom of page) Size Range: Fig. 65 - 1/2"-13 rod sizes, and 5/8"-11 rod sizes (8)TOLCO Fig. 65XT - 3/8"-16 rod size (see below) Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (19.0mm). Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, 3/8"-16 rod will support 1/2" (15mm) thru 4" (1o0mm) pipe 1/2"-13 rod will support 112" (15mm) thru 8" (200mm) pipe Included in the Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load spacing and placement information relating OSHPD projects, please refer to the Seismic Restraint System Guidelines. Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number and finish Fig. 65 Patent #4,570,885 Part F Mac Rec. Load * Approx. Wt./100 No. in. (mm) in. (mm) in. (mm) Maximum loads for clamp with set screw in up or down position. Note: See page 27 for recommended setscrew torque. Fig. 65XT-3/8 - Beam Clamp Feature: Extruded holes allow for more thread engagement of threaded rod and set screw. Weight: Approx. Wt./100 - 28.0 Lbs. (12.7kg) Design Load: 730 Lbs (3.25kN) Finish: Plain or Electro-Galvanized Order By: Part number and finish Approvals: Underwriters Laboratories Listed and FM Approved for uo to 4" (100mm) pipe. Component of State of California OSHPD Approved Seismic Restraints System C &us LISTED Set Screw and Locknut Included 11/8.. C&S �FMo (PTOLCO /�(28.6) LISTED 19/16" 5� /1 3/�. y / 3/411 A��PAN (19.0) Set Screw and 7/8" Locknut Included 13/8" (zz.z) 134.91 Note: See page 27 for recommended setscrew torque. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line by E:TlN 33 Pipe Hangers & Supports Beam Clamps Fig. 66 - Reversible Steel C-Type Beam Clamp 11/4" (31.7mm) Throat Opening Size Range: 3/8"-16, 1/2"-13 rod sizes, and 5/8"-11 rod sizes Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 11/4" (31.7mm). Component of State of (g)TDLC0California OSHPD Approved Seismic Restraints System Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (WL). Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, 3/8"-16 rod will support 1/2" (15mm) thru 4" (100mm) pipe 1/2"-13 rod will support 1/2" (15mm) thru 8" (200mm) pipe Included in the Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load spacing and placement information relating OSHPD projects, please refer to the Seismic Restraint System Guidelines. Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number and finish ' Maximum loads for clamp with set screw in up or down position. Note: See page 27 for recommended setscrew torque. ClVL1N5 Set S[ Locknu All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 34 B-Line by Ect•N Beam Clamps Size Range: 3/8"-16 and 1/2"-13 rod sizes Material: Stainless Steel (Type 316 or 304) Fig. 67SS - Stainless Steel Reversible C-Type Beam Clamp 3/4" (19.omm) Throat Opening Fig. 68SS - Stainless Steel Reversible C-Type Beam Clamp Wide Mouth c &GIs LISTED tTOLC❑ Function: Recommended for hanging from steel beams where flange thickness does not exceed 3/4" (19.0mm) for Fig. 67SS or 11/4" (31.7mm) for Fig. 68SS. Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Conforms to Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 19. Meets or exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13. 3/8"-16 rod will support 1/2" (15mm) thru 4" (loomm) pipe 1/2"-13 rod will support 1/2" (15mm) thru 8" (200mm) pipe Order By: Part number and stainless steel type. icrew and Locknut Included Fig. 67SS i A Part F G Test Load Approx.11 67SS-% 15/8" (41.3) 11 /8" (28.6) 1500 (6.67) 84 (38.1) 67SS-1/2 15/8" 1 (41.3) 11 /8" (28.6) 4050 (18.01) 170 (77.1) I ; -�_ Fig. 68SS Part F Test Load Approx.11 68SS-3/8 2" (50.8) 1500 (6.67) 84 (38.1) 68SS-1/2 21 /4" (57.1) 1 4050 (18.01) 170 (77.1) Note: See page 27 for recommended setscrew torque. E — G — C F I T B-Line by E:TlN All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 35 Pipe Hangers & Supports Beam Clamps B303-B309 - Beam Clamps Size Range: 1/4"-20 thru 5/8"-11 rod Material: Steel Function: Designed for attaching a hanger rod to the flange of a beam. Approvals: Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 19 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 19. Finish: Elect ro-Galvan ized or Hot -Dip Galvanized Order By: Part number and finish. When retaining strap is required, order B312 separately. See page 39. Recommended Set Screw Torque: 3/8"-16 = 150 in-Ibs (16.9 N•m) 1/2"-13 = 350 in-Ibs (39.5 N•m) _ I Set Screw Included 7/8" (22.2) Maximum Flange Thickness Part B303 B304 Rod 1/4"-20 5/16"-18 Size Setscrew 3/8"-16 3/8"-16 25/16" 25/16" C (58.7) (58.7) T 11 Ga. 11 Ga. (3.0) (3.0) Design 400 600 Load (1.78) Approx. 72 Wt./100 (32.6) (2.67) 72 (32.6) B305 3/8"-16 3/8"-16 25/16" (58.7) 11 Ga. (3.0) 600 (2.67) 72 (32.6) B306 3/8"-16 1/2"-13 27/16" (61.9) 7 Ga. (4.5) 1100 (4.89) 97 (44.0) B307 1/2"-13 1/2"-13 27/16" (61.9) 7 Ga. (4.5) 1100 (4.89) 97 (44.0) B308 1/2"-13 1/2"-13 29/16" (65.1) 1/4" (6.3) 1500 (6.67) 133 (60.3) B309 5/8"-11 1/2"-13 1 29/16" 1 (65.1) 1/4" (6.3) 1 1500 (6.67) 1 133 (60.3) Fig. B321 - Series Beam Clamps Set Screw Size Range: 3/8"-16 thru 3/4"-10 rod Included Material: Steel Function: Designed for attaching a hanger rod to the flange of a beam. Approvals: Conforms to Federal Specification WW-H-171 E & 111/16" (42.8) A-A-1192A, Type 19 and Manufacturers Standardization Society Maximum Flange ANSI/MSS SP-69 & SP-58, Type 19. Thickness Finish: Elect ro-Galvanized or Hot -Dip Galvanized Ordering: Part number and finish. When retaining strap is required, order B312 separately. See page 39. Recommended Set Screw Torque: 1/2"-13 = 350 in-Ibs (39.5 N•m) ' 5/8"-11 = 700 in-Ibs (79.0 N•m) _� r� Minimum Flange Thickness: For B321-1 thru B321-3 = 3/81, (9.5) For B321-4 & B321-5 = 5/8" (15.9) Part B321-1 Rod 3/8"-16 Size Setscrew 1/2"-13 G 39/16" (92.1) 1/4" T (6.3) Design 1300 Load (5.78) Approx. 187 Wt./100 (84.8) B321-2 1/2"-13 1/2"-13 39/16" (92.1) 1/4" (6.3) 1400 (6.23) 186 (84.3) B321-3 5/8"-11 1/2"-13 39/16" (92.1) 1/4" (6.3) 1600 (7.12) 185 (83.9) B321-4 5/8"11 5/8"-11 323/32" (94.4) 5/16" (7.9) 1800 (8.00) 239 (108.4) B321-5 3/4"-10 5/8"-11 323/32" (94.4) 5/16" (7.9) 2000 (8.89) 238 (107.9) ,8n .3) A All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 36 B-Line by Ect•N Beam Clamps Fig. 69 - Beam Clamp Retaining Strap (B-Line 1333167) Size Range: 3/8"-16 thru 3/4"-10 rod 4" (101,6mm) thru 16" (406.4mm) lengths Note: longer lengths are available consult factory Material: Pre -Galvanized Steel Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13. Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mechanism of some kind, such as a hex nut or the beveled locking slot of the Fig. 69R will provide a more secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (WL). Approved for use with any listed beam clamp. Included in the Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load spacing and placement information relating OSHPD projects, please refer to the Seismic Restraint System Guidelines. Finish: Pre -Galvanized Order By: Part number, length (L), and finish. Note: Minimum return on strap is 1" (25.4mm) C Component of State of 11� California OSHPD Approved US Y Seismic Restraints System LISTED TOLC0_ B-Line by E:T-N All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 37 Pipe Hangers & Supports Beam Clamps Fig. 69R - Retrofit Capable Beam Clamp Retaining Strap Size Range: 3/8"-16 & 1/2"-13 rod Component of State of 4" 101,6mm thru 16" 406.4mm lengths (g)TCILCC7 C �� US California OSHPD Approved ( ) ( ) g LISTED Seismic Restraints System Note: longer lengths are available consult factory Material: Pre -Galvanized Steel Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13. Features: Beveled locking slot* is precisely formed to align with the threaded section of a hanger rod or set screw and engage the unit securely. May be used as shown in Section "A -A" or inverted. Allows easy installation for new construction or retrofit applications. Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mechanism of some kind, such as a hex nut or the beveled locking slot of the Fig. 69R will provide a more secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (WL). Approved for use with any listed beam clamp. Included in the Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load spacing and placement information relating OSHPD projects, please refer to the Seismic Restraint System Guidelines. Finish: Pre -Galvanized Order By: Part number, length, and finish. Note: Minimum return on strap is 1" (25.4mm) * Patent #5,947,424 A -A All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Pipe Hangers & Supports 38 by Ect•N Beam Clamps B312 - Retaining Strap Size Range: 9" (228.6mm) to 18" (457.2mm) strap lengths Material: Steel Function: Designed for use with 13303-6309 and B321 beam clamps. Finish: Pre -Galvanized Order By: Part number and finish. Notes: Maximum beam thickness 3/4" (19.0). For thicker beams step up one flange width size. Requires field forming on beam. Material Thickness 14 Gauge (1.9) 13/4-- L (44.4) 1/2 1 1/4" (12.7) (31.7) 1/4 (6.3) I� II I, II B-Line by E:T-N All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 39 Pipe Hangers & Supports Beam Clamps B3O5O - Beam Clamp (TOLCo Fig. 62) A Center of bolt to bottom of beam ; ' Steel Size Material: Steel flange. I I Function: Recommended for the suspending of hanger rod from the center of an I-beam, equally distributing the load on both sides A of the beam. Use with B3210 eye rod, B3211 welded eye rod or B3200 weldless rye nut. Bolt and Nut Included Approvals: Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 21 and Manufacturers Standardization Society ANSI/MSS SP-69 & Bolt size SP-58, Type 21. Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, type, width of flange and finish. B 4" (101.6) Flange 3/16" (4.8) Thickness 1/2" (12.7) Approx.II For 116 (52.6) (194.6) 429 5" (127.0) 5/16" (7.9) 5/8" (15.9) 125 (56.7) 458 (207.8) 6" (152.4) 1/4" (6.3) 3/4" (19.0) 134 (60.8) 486 (220.5) 7" (177.8) 7/16" (11.1) 7/8" (22.2) 143 (64.9) 514 (233.2) 8" (203.2) 7/16" (11.1) 7/8" (22.2) 152 (69.0) 543 (246.3) 9" (228.6) 9/16" (14.3) ill (25.4) 160 (72.6) 571 (259.0) 10" (254.0) 5/8" (15.9) ill (25.4) 169 (76.7) 599 (271.8) 12" (304.8) 5/8" (15.9) 11/4" (31.7) 187 (84.8) 656 (297.6) B3O4O - Adjustable Beam Clamp (TOLCO Fig. 336) Size Range: 3/8"-16 thru 3/4"-10 rod Material: Steel Function: Fits structural I -Beams and wide flange beams, flange widths 31/2" (88.9mm) to 8" (203.2mm), thickness Up to 1/2" (12.7mm). Approvals: Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 54, and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 27. Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number and finish J-Hook and Hex Nut Included C Center of J-Hook to bottom of clamp body. 1- A (Rod Size) Hanger Rod Not Included C B Steel Size All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 40 B-Line by E:J-N Beam Clamps B3055 - Steel Beam Clamp Size Range: 3/8"-16 thru 1 "-8 rod Material: Steel Function: Designed for attaching a hanger rod to be centered under beam flanges. 2" (50.8mm) vertical adjustment is provided in the clamp. Approvals: Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 21 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 21. Finish: Plain or Electro-Galvanized Order By: Part number, flange width, and finish. Steel Size Size Bolt and Nut Included B B Center of cross bolt to bottom of side of hanger _ , rod nut. A (Rod Size) NOTE: Hanger Rod Slots on bottom Not Included portions of clamp halves allow -- 1" (25.4) adjustment for variance in flange widths Hanger Rod Not Included C Rod Size B3055-3/8 3/8"-16 3" B (76.2) C 4" (101.6) Steel 1/4" x 11/4" Size (6.3 x 31.7) Design 550 Load (2.44) B3055-1/2 1/2"-13 3" (76.2) 4" (101.6) 1/4" x 11/2" (6.3 x 38.1) 850 (3.78) B3055-5/8 5/8"-11 31/4" (82.5) 41/2" (114.3) 3/8" x 11/2" (9.5 x 38.1) 1100 (4.89) B3055-3/4 3/4"-10 31/4" (82.5) 41/2" (114.3) 3/8" x 2" (9.5 x 50.8) 1500 (6.67) B3055-7/8 1 7/8"-9 31/2" (88.9) 5" (127.0) 1/2" x 2" (12.7 x 50.8) 2600 (11.56) B3055-1 1 "-8 31/2" (88.9) 51/2" (139.7) 1/2" x 21/2" (12.7 x 63.5) 4300 (19.12) Note: Box Style Furnished For B3055 3/s x 2" B3055 3/s x 3" B3055 3/s x 4" B3055 1/2 x 2" B3055 1/2 x 3" B3055 1/2 x 4" B3055-5/8 x 2" B3055-5/8 x 3" B3055-5/8 x 4" B3055 3/4 x 2" B3055 3/4 x 3" B3055 3/4 x 4" B3055-7/8 x 3" B3055-7/8 x 4" B3055-7/8 x 5" B3055-1 x 3" B3055-1 x 4" B3055-1 x 5" B3055-1 x 6" B3055-11/8 x 4" B3055-11/8 x 5" B3055-11/8 x 6" B3055-11/8 x 7" B3055-11/4 x 4" B3055-11/4 x 5" B3055-11/4 x 6" B3055-11/4 x 7" ,e 4-- Width W (101.6) I 168 (76.2) ApproximateII I 201 (91.2) For Beam I 328 (148.8) Clamp Size Lbs. I 434 (196.8) (kg) IB3055-1 657 (298.0) 797 (361.5) 5" (127.0) 181 (82.1) 217 (98.4) 352 (159.6) 466 (211.4) 667 (302.5) 824 (373.7) 6-- (152.4) 193 (87.5) 231 (104.8) 373 (169.2) 495 (224.5) 705 (319.8) 877 (397.8) T- (177.8) 205 (93.0) 246 (111.6) 395 (179.2) 525 (238.1) 744 (337.5) 926 (420.0) 8" (203.2) 214 (97.1) 256 (116.1) 411 (186.4) 546 (247.6) 773 (350.6) 962 (436.3) 10" (254.0) 235 (106.6) 282 (127.9) 449 (203.6) 596 (270.3) 840 (381.0) 1046 (474.4) 12" (304.8) 259 (117.5) 311 (141.0) 493 (223.6) 655 (297.1) 918 (416.4) 1143 (518.4) B-Une by FIT-N All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 41 Pipe Hangers & Supports Beam Clamps B3054 - Malleable Iron Beam Clamp With Extension B3054WO - Malleable Iron Beam Clamp Without Extension JOLCO Fig. 329) Size Range: 3/8"-16 thru 7/8"-9 rod Material: Malleable Iron C 0L u5 LISTED Function: Designed for attaching a hanger rod to the bottom flange of a beam. Adjustable for flange widths of 3" (76.2mm) to 7" (177.8mm) and a flange thickness of no greater than 5/8" (15.9mm). Approvals: Underwriters Laboratories Listed. Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 30 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 30. Finish: Plain or Electro-Galvanized Ordering: Part number and finish IWO B3054 Clamping Rod and Nuts Included E Rod Take -Out A (Rod Size) Hanger Rod Not Included B3054-3/8 Rod Size 3/8"-16 411/16" (119.1) 49/16" Rod Take Out (115.9) 'E' For 45/8" Beam Flange (117.5) Width 4" Of (101.6) 31/8" 19 (79.4) B3054-1/2 1/2"-13 413/16" (122.2) 41/2" (114.3) 45/16" (109.5) 315/16" (10Q0) 31/4" (82.5) B3054-5/8 5/8"-11 47/8" (123.8) 45/8" (117.5) 43/8" (111.1) 33/4" (95.2) 35/16" (84.1) B3054-3/4 3/4"-10 51/8" (130.2) 5" (127.0) 45/8" (117.5) 41/4" (107.9) 33/4" (95.2) B3054-7/8 7/8"-9 53/16" (131.8) 47/8" (123.8) 411/16" (119.1) 45/16" (109.5) 33/4" (95.2) B3054-3/8 Design 730 Load (3.25) Max. Iran Pipe 4" Size Per UL (100) Approx. 236 Wt./100 (107.0) B3054-1/2 1350 (6.00) 8" (200) 254 (115.2) B3054-5/8 1365 (6.07) 10" (250) 260 (117.9) B3054-3/4 1365 (6.07) 10" (250) 278 (126.1) B3054-7/8 1365 (6.07) 10" (250) 292 (132.4) E All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 42 B-Line by E:T■N Beam Clamps B3291, B3292, B3293, B3294, B3295, B3296, B3297, B3298 UFS Beam Clamp With Weldless Eye Nut Available with left hand threads by adding an L to part number Example: B3291L-* Size Range: 3/8"-16 thru 2"-41/2 rod Material: Forged Steel Function: Designed for attaching a hanger rod to the bottom flange of a beam. Adjustable from flange widths of 3" (76.2mm) to 15" (381.0mm). and flange thickness of no greater than 11/32" (26.2mm). Approvals: Complies with Federal Specification WW-H-171 E & A-A-1192A (Type 28 without links; Type 29 with links,) and ANSI/MSS SP-58 (Type 28 without links; Type 29 with links). Finish: Plain or Electro-Galvanized Order By: Part number, rod size and finish. Note: Design load for B3291 thru B3295 based on maximum rod size shown. Use the appropriate all threaded rod design load shown on page 300 for sizes less than maximum. s Maximum Beam Flange Rod Size A Part No. Thickness (Specify) B C Design Load Approx. Wt./1 11 'id B3291 * .60 (15.2) 3/8"-16,1/2"-13, 5/8"-11 3/4"-10 11/4" (31.7 ) 11/8" (28.6) 3230 (14.36) 390 (176.9) B3292-* .60 (15.2) 7/8"-9, 1 "-8 111/16" (42.9) 11/8" (28.6) 5900 (26.24) 915 (415.0) B3293-*A .60 (15.2) 3/8" 16,1/2"-13, 5/8" 11, 111/16" (42.9) 11/8" (28.6) 5900 (26.24) 1300 (589.6) 3/4"-10, 7/8"-% 1 "-8 B3294-* 1.031 (26.2) 7/8"-%1"-8 11/2" (38.1) 11/8" (28.6) 5900 (26.24) 2165 (982.0) B3295-*A 1.031 (26.2) 7/8"-9, 1"-8 11/2" (38.1) 11/8" (28.6) 5900 (26.24) 3385 (1535.4) B3296-* 1.031 (26.2) 1"-8, 11/8"-7, 21/8" (54.0) 11/8" (28.6) 11500 (51.15) 2390 (1084.1) 11/4"-7, 11/2"-6 B3297-*A 1.031 (26.2) 11/8"-7, 11/4"-7, 11/2"-6 21/8" (54.0) 11/8" (28.6) 11500 (51.15) 3575 (1621.6) B3298-* 1.031 (26.2) 13/4"-5, 2"-41/2 49/16" 1 (115.9) 11/8" 1 (28.6) 11500 (51.15) 3675 1 (1666.9) B3291 * 41/2" 55/16" 41/16" 35/8" 27/8" Rod Take -- -Out ForFlange -- I - -- - -- -- B3292-* - 43/4" 47/16" 41/16" 33/8" -- -- -- - -- -- -- -- B3293-*A -- -- - 515/16" 6" 55/16" 511 - -- -- -- -- B3294-* -- 613/16" 65/8" 63/81, 57/8" 57/811 53/8" 413/16" -- -- -- -- -- B3295-* A 81/8" 73/4" 71/8" 65/8" 61/16" B3296-* -- 73/16" 7" 63/4" 61/4" 65/16" 513/16" 53/16" - -- -- -- -- B3297-* A 81/2" 81/8" 71/2„ 7" 67/16" B3298-* -- 83/8" 87/16" 83/16" 73/4" 73/4" 71/4" 65/81, -- -- -- -- To determine (mm) in the above chart, multiply inches by 25.4. Rod Size required to finish part number (see Rod Size 'A' in top chart). A These part numbers are furnished with links. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-L�ne by FIT -IN 43 Pipe Hangers & Supports Beam Clamps B3042 - Top Beam Hook (TOLCO Fig. 61) Size Range: 3/8"-16 and 1/2"-13 rod Material: Steel Function: Designed for attaching hanger rod to the top flange of a beam or angle truss. The support rod completes assembly and secures it to the flange. Finish: Plain or Elect ro-Galvanized Order By: Part number flange width, flange thickness and finish. A (Rod Size) Hanger Rod Not Included Allows 1/8" (3.2) clearance between hanger rod and flange of beam. For Pipe Size Design Load B3042-3/8 3/8"-16 3/4"-2" (20-50) 300 (1.33) B3042-1/2 1/2"-13 21/2 31/2 (65-90) 500 (2.22) B3045 - Side Beam Clamp (TOLCO Fig. 335) Size Range: 3/8"-16 thru 7/8"-9 rods 3" (76.2mm) thru 9" (228.6mm) flange widths Material: Steel Function: Designed for attaching hanger rod to the side of a beam flange. Works on top or bottom of beam. Approvals: Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 53 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 25. Finish: Plain or Electro-Galvanized Order By: Part number, flange width and thickness, and finish A (Rod Size) Hanger Rod Not Included if B B3045-3/8 Rod 3/8"-16 Size B 21/16" (52.4) 3" Flange - 9" Width (76.2 - 228.6) Design 300 Load (1.33) B3045-1/2 1/2"-13 25/16" (58.7) 3" - 9" (76.2 - 228.6) 500 (2.22) B3045-5/8 5/8"-11 27/16" (61.9) 3" - 9" (76.2 - 228.6) 700 (3.11) B3045-3/4 5/8"-11 27/8" (73.0) 3" - 9" (76.2 - 228.6) 800 (3.55) B3045-7/8 5/8"-11 3" (76.2) 1 3" - 9" (76.2 - 228.6) 1 1200 (5.33) Bolt and Nut Included All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 44 B-Line by Ect•N Beam Clamps B3042T - Bar Joist Hanger (TOLCO Fig. 61T) Size Range: 3/8"-16 and 1/2"-13 rod Material: Steel Function: Designed to hook on top chord of metal bar joist. Hanger rod is threaded into product and secured with a wash- er and nut. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) for up to 4" (loomm) pipe with 3/8"-16 rod, up to 6" (150mm) pipe with 1/2"-13 rod. Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, width and thickness of bar joist, and finish. C@" LISTED Rod Size For Pipe Size Design Load Approx. Wt./100 Part No. Size in. (mm) Lbs. (M) Lbs. (kg) B-Line by E:T-N All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 45 Pipe Hangers & Supports Beam Clamps Fig. 130 - Trus Joist Beam Clamp (B-Line Fig. B3052) Size Range: 130-1 = TJI 35 130-2 = - 130-3 = TJI 25 130-4 = TJI 55 & 65 130-5 = TJI 75 130-6 = TJI 96 Material: Steel Function: Designed for attachment to trus joist beams. Use with B3210 Series eye rods. Approvals: Sizes 1 - 6 are Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) list through 4" (loomm) pipe. All Fig. 130 Beam Clamps meet requirements of Factory Mutual Engineering and NFPA 13, through 4" (loomm) pipe. Finish: Electro-Galvanized or Hot -Dip Galvanized Order By: Part number and finish. ce us w LISTED FM A H Hardware Included 1.r (25.4) (3.2) III (50.8) 1 W. (19.0) Material Thickness (9.5) 11 Gauge (3.0) 130-1 HardwarePart 3/8"-16 31/4" (82.5) 11/2" (38.1) 25/16" (58.7) pp11 65 (29.5) 130-2 3/8"-16 31/2" (88.9) 13/4" (44.4) 21/2" (63.5) 70 (31.7) 130-3 3/8"-16 31/4" (82.5) 11/2" (38.1) 13/4" (44.4) 58 (26.3) 130-4 3/8"-16 31/2" (88.9) 11/2" (38.1) 31/2" (88.9) 83 (37.6) 130-5t 1/2"-13 35/8" (92.1) 13/4" (44.4) 31/2" (88.9) 86 (39.0) 130-6t 1/2"-13 41/2" 1 (114.3) 1 21/2" 1 (63.5) 1 37/8" 1 (98.4) 1 101 1 (45.8) 'H' and Ware beam dimensions. Maximum Recommended Load 500 Lbs. (2.22kN) Safety Factor of 5 t Larger bolts and I -rods are required for 5" (125mm) and 6" (150mm) pipe sizes All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 46 B-Line by E:T■N Pipe Hangers Pipe hangers offered in this section are designed to support insulated or non -insulated pipe allowing for vertical adjustment and limited movement in the piping system. Materials Carbon Steel, Malleable Iron and AISI Type 304 & 316 Stainless Steel are used in the manufacturing of pipe hangers. Other materials are available. Finishes The standard finishes for mechanical supports are plain steel (oil coated) sometimes referred to as black, Electro-Galvanized Zinc (ASTM B633 SC3), Pre -Galvanized (ASTM A653 G90), Hot -Dip Galvanized After Fabrication (ASTM A123), Red Primer, Plastic Coating, DURA-GREEN'", DURA-COPPER'" and other special coatings are available upon request. Note: Due to the design of some products, (threads, connecting hardware, swivels, etc.) items may or may not be uniformly coated with special finishes i.e. Hot -Dip Galvanized, DURA-GREEN, DURA-COPPER, PVC etc. In some cases, the hanger itself may be coated, however, the hardware may be supplied Electro-Plated, DURA-COPPER Painted or Stainless Steel. Consult B-Line Systems for availability. Approvals (as noted) Items in this section are Underwriters Laboratories Listed, Factory Mutual Approved, and comply with Federal Specification WW-H-171 E & A-A-1192A or Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58. Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. by -Line by Ect•N 47 Pipe Hangers & Supports Pipe Hangers Fig.1 CBS - Clevis Pipe Spacer (Cooper B-Line B3100PS) Size Range: Size 1 " (25mm) thru 20" (500mm) clevis hanger Material: Steel Function: Used as a spacer at a seismic brace location to keep clevis hanger from collapsing during seismic event. Approvals: Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the Seismic Restraint Systems Guidelines. Installation Note: Fig. 1 CBS fits easily over the cross bolt and attaches by pinching tabs down. Finish: Pre -Galvanized. Contact B-Line for alternative finishes and materials. Order By: Part number and finish. 1CBS-1 Pipe 1" Size (25) Approx.00 3.2 (1.4) ICBS-11/4 11/4" (32) 4.1 (1.8) 1CBS-11/2 11/2" (40) 4.8 (2.2) 1CBS-2 2" (50) 9.4 (4.2) ICBS-21/2 21/2" (65) 11.4 (5.2) 1CBS-3 3" (75) 13.9 (6.8) ICBS-31/2 31/2" (90) 16.0 (7.2) 1 CBS-4 4" (100) 18.0 (8.1) 1CBS-5 5" (125) 27.3 (12.4) 1CBS-6 6" (150) 32.5 (14.7) 1CBS-8 8" (200) 42.5 (19.2) 1CBS-10 10" (250) 72.7 (32.9) 1CBS-12 12" (300) 86.3 (39.1) ICBS-14 14" (350) 157.6 (71.5) 1CBS-16 16" (400) 183.7 (83.3) 1CBS-18 18" (450) 224.6 (101.9) 1CBS-20 20" (500) 254.0 (115.2) Component of State of California OSHPD Approved Seismic Restraints System All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 48 B-Line by E:T■N Pipe Hangers B3100 - Standard Clevis Hanger (TOLGO Fig.1) SLIDE-RITETM Clevis Hanger Features Pipe will not `pinch' when installing. 15' swing in either direction allows pipe to easily feed thru. Engineered design aligns bolt holes for quicker overhead installation. 'SLIDE-RITETM Clevis Hanger design, as shown below, for sizes 2, 21/2, 3, 4, 5 & 6. Pat. No. 5,848,770 5,924,655 C VL us <FM LISTED Component of State of California OSHPD Approved Seismic Restraints System B Bottom of pipe to top of hanger. C Not Center of pipe to top of hanger. D Rod Take -Out Center of pipe to bottom of hangerrod. E Minimum thread length of hangerrod F Adjustment Top of cross bolt to bottom of hanger rod nut inside the hanger. r Part i B3100-1/2 NominalRod 1/2" (15) Size A 3/8"-16 3/8"-16 21/8" B (54.0) 13/4" G (44.4) 15/16" 1 (23.8) B3100-3/4 3/4" (20) 3/8"-16 3/8"-16 21/2" (63.5) 2" (50.8) 11/8" (28.6) B3100-1 1" (25) 3/8"-16 3/8"-16 27/8" (73.0) 21/4" (57.1) 13/8" (34.9) B3100-11/4 11/4" (32) 3/8"-16 3/8"-16 31/2" (88.9) 211/16" (68.2) 113/16" (46.0) B3100-11/2 11/2" (40) 3/8"-16 3/8"-16 4" (101.6)' 31/16" (77.8) 21/4" (57.1) B3100-2 * 2" (50) 3/8"-16 3/8"-16 41/2" (114.3) 35/16" (84.1) 21/2" (63.5) B3100-21/2 * 21/2" (65) 1/2"-13 3/8"-16 53/8" (136.5) 315/16" (100.0) 31/16" (77.8) B3100-3 * 3" (80) 1/2"-13 3/8"-16 61/2" (165.1) 43/4" (120.6) 315/16" (100.0) B3100-31/2 31/2" (90) 1/2"-13 3/8"-16 71/4" (184.1) 51/4" (133.3) 41/16" (103.2) B3100-4 * 4" (100) 5/8"-11 3/8"-16 73/4" (196.8) 51/2" (139.7) 51/2" (139.7) B3100-5 * 5" (125) 5/8"-11 1/2"-13 83/4" (222.2) 61/8" (155.6) 6" (152.4) B3100-6 * 6" (150) 3/4"-10 1/2"-13 105/16" (261.9) 615/16" (176.2) 7" (177.8) B3100-8 8" (200) 3/4"-10 1/2"-13 123/4" (323.8) 87/16" (214.3) 71/8" (181.0) B3100-10 10" (250) 7/8"-9 5/8"-11 151/8" (384.2) 93/4" (247.6) 83/8" (212.7) B3100-12 12" (300) 7/8"-9 5/8"-11 171/2" (444.5) 111/8" (282.6) 911/16" (246.1) B3100-14 14" (350) 1"-8 193/8" (492.1) 123/8" (314.3) 105/8" (269.9) B3100-16 16" (400) 1 "-8 213/8" (542.9) 133/8" (339.7) 119/16" (293.7) B3100-18 18" (450) 1 "-8 25" (635.0) 16" (406.4) 143/16" (360.3) B3100-20 20" (500) 11/4"-7 283/4" (730.2) 173/4" (450.8) 165/8" (422.3) B3100-24 24" (600) 11/4"-7 323/4" (831.8) 193/4" (501.6) 185/8" (473.1) B3100-30 30" (750) 11/4"-7 3915/16" (1014.4) 2415/16" (633.4) 223/4" (577.8) B3100-36 36" (900) 11/4"-7 46" (1168.4) 28" (711.2) 25" (635.0) B-Line by E:T-N All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 49 Pipe Hangers & Supports Pipe Hangers B3100 - Standard Clevis Hanger (TOLCO Fig.1) Size Range: 1/2" (15mm) to 36" (900mm) Material: Steel Component of State of California OSHPD Approved Seismic Restraints System Function: Recommended for the suspension of non -insulated pipe or insulated pipe with a B3151 shield. Note: When an oversized clevis is used, a pipe spacer should be placed over the cross bolt to assure that the lower U-strap will not move in on the bolt. When attaching seismic bracing to the clevis hangers, a B3100PS (cross bolt spacer) must be installed. See Seismic Restraints Approval Guidelines. Order pipe sleeves Fig. 1CBS-(pipe size) separately. Approvals: Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the B-Line/TOLCO Seismic Restraint Systems Guidelines. Underwriter's Laboratories Listed in the USA (UL) and Canada (cUL) for sizes 3/4" (2omm) thru 12" (300mm). Factory Mutual Engineering Approved (FM) for 3/4" (20mm) thru 12" (300mm) pipe. Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 1 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 1. Also available to accommodate rod schedule per per National Fire Protection Association (NFPA) Pamphlet 13. Maximum Temperature: 650°F (343°C). Standard Finish: Plain, Electro-Galvanized, DURA-GREEN"", or Hot -Dip Galvanized C& us <FM also available in Stainless Steel LISTED Order By: Part number and finish. For AWWA - Ductile Iron Clevis Hangers, see 133102, page 51. ** Note: Do not use the dimensions shown in the B3100 chart for NFPA hanger sizes. Contact B-Line for NFPA rod sizing on 1/2" (15mm) thru 12" (300mm) pipe. Part numbers will be 1 NFPA-pipe size. B3100-1/2 21/2" (63.5) 7/16" (11.1) Design 730 Load (3.25) Approx.II 25 (11.3) B3100-3/4 21/2" (63.5) 1/2" (12.7) 730 (3.25) 29 (13.1) B3100-1 21/2" (63.5) 5/8" (15.9) 730 (3.25) 35 (15.9) B3100-11/4 21/2" (63.5) 7/8" (22.2) 730 (3.25) 40 (18.1) B3100-11/2 21/2" (63.5) 13/16" (30.2) 730 (3.25) 42 (19.0) B3100-2 * 21/2" (63.5) 15/8" (41.3) 730 (3.25) 52 (23.6) B3100-21/2 * 21/2" (63.5) 2" (50.8) 1350 (6.00) 90 (40.8) B3100-3 * 21/2" (63.5) 2" (50.8) 1350 (6.00) 110 (49.9) B3100-31/2 21/2" (63.5) 2" (50.8) 1350 (6.00) 142 (64.4) B3100-4 * 21/2" (63.5) 2" (50.8) 1430 (6.36) 132 (59.9) B3100-5 * 21/2" (63.5) 2" (50.8) 1430 (6.36) 215 (97.5) B3100-6 * 3" (76.2) 2" (50.8) 1940 (8.63) 320 (145.1) B3100-8 31/2" (88.9) 25/16" (58.7) 2000 (8.89) 485 (220.0) B3100-10 31/2" (88.9) 25/16" (58.7) 3600 (16.01) 846 (383.7) B3100-12 31/2" (88.9) 25/8" (66.7) 3800 (16.90) 1083 (491.2) B3100-14 IP 4" (101.6) 27/8" (73.0) 4200 (18.68) 1432 (649.5) B3100-16 4" (101.6) 211/16" (68.3) 4600 (20.46) 2200 (997.9) B3100-18 41/2" (114.3) 315/16" (100.0) 4800 (21.35) 2500 (1134.0) B3100-20 5" (127.0) 53/8" (136.5) 4800 (21.35) 4400 (1995.8) B3100-24 5" (127.0) 53/8" (136.5) 4800 (21.35) 5000 (2268.0) B3100-30 5" (127.0) 61/4" (158.7) 6000 (26.69) 6600 (2993.7) B3100-36 5" (127.0 57f16" (138.1) 6000 (26.69) 8474 (3843.8) SLIDE-RITETM Clevis Hanger design, as shown above, for sizes 2, 21h, 3, 4, 5 & 6. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 50 B-Line by E:T■N Pipe Hangers B3102 - A.W.W.A. Clevis Hanger (TOLCO Fig. ci) Size Range: 4" (100mm) to 24" (600mm) Material: Steel Function: Recommended for the suspension of flanged or bell and spigot A.W.W.A. cast iron or ductile iron pipe. The O.D. of the A.W.W.A. iron pipe is shown in the data table. Approvals: Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 1 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 1. Standard Finish: Plain & Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Part number and finish. A B Bottom of pipe t0 top of hanger. of C Center of pipe to top of hanger. D Rod Take -Out Center of pipe to bottom of hangerrod. E Minimum thread length of hangerrod F Adjustment Top of cross bolt to bottom of hanger rod nut inside the hanger. B3102-4 Pipe O.D. 4.80 (121.9) Rod Size 5/8"-11 B 85/16" (211.1) 513/16" G (147.6) D 45/8" (117.5) 21/2" E (63.5) 2" F (50.8) Design 1430 Load (6.36) Approx. Wt./1 00 203 (92.1) B3102-6 6.90 (175.2) 3/4"-10 105/8" (269.9) 71/16" (179.4) 513/16" (147.6) 3" (76.2) 2" (50.8) 1940 (8.63) 352 (159.6) B3102-8 9.05 (229.9) 3/4"-10 131/4" (336.5) 85/8" (219.1) 73/16" (182.5) 31/2" (88.9) 21/8" (54.0) 2000 (8.89) 532 (241.3) B3102-10 11.10 (281.9) 7/8"-9 157/8" (403.2) 101/4" (260.3) 811/16" (220.6) 31/2" (88.9) 21/4" (57.1) 3600 (16.01) 800 (362.9) B3102-12 13.20 (335.3) 7/8"-9 18" (457.2) 115/16" (287.3) 93/4" (247.6) 31/2" (88.9) 21/4" (57.1) 3800 (16.90) 1152 (522.5) B3102-14 15.30 (388.6) 1 "-8 203/8" (517.5) 125/8" (320.7) 113/16" (281.6) 4" (101.6) 27/8" (73.0) 4200 (18.68) 1449 (657.2) B3102-16 17.40 (441.9) 1"-8 231/2" (569.9) 1411/16" (373.1) 127/8" (327.0) 4" (101.6) 33/8" (85.7) 4600 (20.46) 2100 (952.6) B3102-18 19.50 (495.3) 1 "-8 255/8" (650.9) 153/4" (400.0) 1315/16" (354.0) 41/2" (114.3) 33/8" (85.7) 4800 (21.35) 2294 (1040.5) B3102-20 21.60 (548.6) 11/4"-7 291/2" (749.3) 189/16" (471.5) 177/16" (442.9) 5" (127.0) 413/16" (122.2) 4800 (21.35) 3887 (1763.1) B3102-24 25.80 (655.3) 11/4"-7 33" (838.2) 191/8" (508.0) 20" (485.8) 5" (127.0) 51/4" (133.3) 4800 (21.35) 4844 (2197.2) B-Une by FIT-N All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 51 Pipe Hangers & Supports Pipe Hangers B3108 - Extended Clevis Hanger (Tol-CO Fig.1A) Size Range: 3/4" (20mm) thru 12" (300mm) pipe Material: Steel Function: Recommended for the suspension of insulated pipe where the temperature does not require the use of slides, guides, or rollers for movement. Approvals: Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 1 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 1. Maximum Temperature: 650oF (3430C). Order By: Part number and finish. For service For Stainless Steel add SS to part number. Standard Finish: Plain, Electro-Galvanized or Hot Dip Galvanized For service temperatures of 750°F (399°C) thru 1050°F (565°C) specify Type 304 Stainless Steel A (Rod Size) Hanger Rod Not Included B3108-3/4 Nominal 3/4" Pipe Size (20) Rod 3/8"-16 43/8" (111.1) 313/16" (96.8) 1 31/16" (77.8) B3108-1 1" (25) 3/8"-16 43/4" (120.6) 41/16" (103.2) 31/4" (82.5) B3108-11/4 11/4" (32) 3/8"-16 53/8" (136.5) 41/2" (114.3) 35/16" (84.1) B3108-11/2 11/2" (40) 3/8"-16 67/8" (174.6) 515/16" (150.8) 51/8" (130.2) B3108-2 2" (50) 3/8"-16 813/16" (223.8) 75/8" (193.7) 67/8" (174.6) B3108-21/2 21/2" (65) 1/2"-13 10" (254.0) 81/2" (215.9) 79/16" (192.1) B3108-3 3" (80) 1/2"-13 105/8" (269.9) 813/16" (223.8) 77/8" (200.0) B3108-4 4" (100) 5/8"-11 1113/16 (300.0) 91/2" (241.3) 83/8" (212.7) B3108-5 5" (125) 5/8"-11 131/8" (333.4) 105/16" (261.9) 91/8" (231.8) B3108-6 6" (150) 3/4"-10 143/8" (365.1) 11" (279.5) 911/16" (246.0) B3108-8 8" (200) 3/4"-10 163/4" (425.4) 123/8" (314.3) 111/8" (282.6) B3108-10 10" (250) 7/8"-9 191/4" (488.9) 1313/16" (350.8) 125/16" (312.7) B3108-12 12" (300) 1 7/8"-9 1 215/8" (549.3) 153/16" (385.8) 135/8" (346.1) B Bottom of pipe to top of hanger. C Center of pipe to top of hanger. D Rod Take -Out Center of pipe to bottom of hangerrod. E Minimum thread length of hangerrod. F Adjustment Top of cross bolt to bottom of hanger rod nut inside the hanger. H Maximum insulation thickness. Part i B3108-3/4 21/2" (63.5) 1/2" (12.7) 2" (50.8) 730 (3.25) 45 (20.4) B3108-1 21/2" (63.5) 5/8" (15.9) 2" (50.8) 730 (3.25) 49 (22.2) B3108-11/4 21/2" (63.5) 7/8" (22.2) 2" (50.8) 730 (3.25) 55 (24.9) B3108-11/2 21/2" (63.5) 13/16" (30.2) 2" (50.8) 730 (3.25) 67 (30.4) B3108-2 21/2" (63.5) 15/8" (41.3) 4" (101.6) 730 (3.25) 83 (37.6) B3108-21/2 21/2" (63.5) 2" (50.8) 4" (101.6) 1350 (6.00) 177 (80.3) B3108-3 21/2" (63.5) 2" (50.8) 4" (101.6) 1350 (6.00) 191 (86.6) B3108-4 21/2" (63.5) 2" (50.8) 4" (101.6) 1430 (6.36) 237 (107.5) B3108-5 21/2" (63.5) 2" (50.8) 4" (101.6) 1430 (6.36) 302 (137.0) B3108-6 3" (76.2) 2" (50.8) 4" (101.6) 1940 (8.63) 397 (180.1) B3108-8 31/2" (88.9) 25/16" (58.7) 4" (101.6) 2000 (8.89) 582 (264.0) B3108-10 31/2" (88.9) 25/16" (58.7) 4" (101.6) 3600 (16.01) 968 (439.1) B3108-12 J 31/2" (88.9) 25/8" (66.7) 4" (101.6) 3800 (16.90) 1221 (553.8) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 52 B-Line by E:J-N Pipe Hangers B3100C - Standard Clevis Hanger - Plastic Coated (TOLCo Fig.1 PVC) B310OF - Standard Clevis Hanger - Felt Lined for Copper Tubing (TOLCO F19.1 F) Size Range: 1/2" (15mm) to 8" (200mm) pipe Material: Steel Insulation Material: 3/16" (4.8mm) Felt Service: The B3100F is designed for the suspension of copper tube so as to prevent electrolysis between tubing and hanger. The B3100C is designed for steel or other pipe types of the same O.D. Both B3100F and B3100C act to reduce noise and vibration in pipe or tubing systems. Approvals: Underwriter's Laboratories Listed in the USA (UL) and Canada (cUL). Maximum Temperature: 650OF (343°C). Standard Finish: Plain, Electro-Galvanized, or Hot -Dip Galvanized. Contact B-Line for alternative finishes and materials. Order By: Part number and finish. C@ W. LISTED B A Bottom of pipe to top of hanger. (Rod Size) C Hanger Rod Not Center of pipe to top of hanger. Included 0 Rod Take -Out Center of pipe to bottom of hanger rod. E Minimum thread length of hangerrod ii F Adjustment C Top of cross bolt to bottom of hanger rod nut inside the hanger. Part ' B3100-1/2 Pipe 1/2" Size (15) Rod 3/8"-16 21/8" (54.0) 111/16" (42.9) 15/16" (23.8) B3100-3/4 3/4" (20) 3/8"-16 27/16" (61.9) 17/8" (47.6) 11/8" (28.6) B3100-1 1" (25) 3/8"-16 213/16" (71.4) 21/8" (54.0) 13/8" (34.9) B3100-11/4 11/4" (32) 3/8"-16 37/16" (87.3) 29/16" (65.1) 113/16" (46.0) B3100-11/2 11/2" (40) 3/8"-16 4" (101.6)' 3" (76.2) 21/4" (57.1) B3100-2 2" (50) 3/8"-16 41/2" (114.3) 31/4" (82.5) 21/2" (63.5) B3100-21/2 21/2 (65) 1/2"-13 59/16" (141.3) 4" (101.6) 31/16" (77.8) B3100-3 3" (80) 1/2"-13 63/4" (171.4) 47/8" (123.8) 315/16" (100.0) B3100-31/2 31/2" (90) 1/2"-13 7" (177.8) 5" (127.0) 41/16" (103.2) B3100-4 4" (100) 5/8"-11 713/16" (198.4) 51/2" (139.7) 43/8" (111.1) B3100-5 5" (125) 5/8"-11 91/16" (230.2) 61/8" (155.6) 5" (127.0) B3100-6 6" (150) 3/4"-10 107/16" (265.1) 615/16 (176.2) 511/16" (144.5) B3100-8 8" (200) 3/4"-10 123/4" (323.8) 1 83/8" (212.7) 1 71/8" (181.0) B3100-1/2 E 21/2" (63.5) Adjustment �/16" F (11.1) Design 730 Load (3.25) Approx.tt 25 (11.3) B3100-3/4 21/2" (63.5) 1/2" (12.7) 730 (3.25) 29 (13.1) B3100-1 21/2" (63.5) 5/8" (15.9) 730 (3.25) 35 (15.9) B3100-11/4 21/2" (63.5) 7/8" (22.2) 730 (3.25) 40 (18.1) B3100-11/2 21/2" (63.5) 13/16" (30.2) 730 (3.25) 42 (19.0) B3100-2 21/2" (63.5) 15/8" (41.3) 730 (3.25) 52 (23.6) B3100-21/2 21/2" (63.5) 2" (50.8) 1350 (6.00) 90 (40.8) B3100-3 21/2" (63.5) 2" (50.8) 1350 (6.00) 110 (49.9) B3100-31/2 21/2" (63.5) 2" (50.8) 1350 (6.00) 142 (64.4) B3100-4 21/2" (63.5) 2" (50.8) 1430 (6.36) 132 (59.9) B3100-5 21/2" (63.5) 2" (50.8) 1430 (6.36) 215 (97.5) B3100-6 3" (76.2) 2" (50.8) 1940 (8.63) 320 (145.1) B3100-8 31/2" (88.9) 25/16" (58.7) 2000 (8.89) 485 (220.0) B3100C B3100F B-Erne by FIT-N All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 53 Pipe Hangers & Supports Pipe Hangers B3690 - J-Hanger for Pipe or Conduit (ToLCo Fig. 3) B3690F - Felt Lined J-Hanger for Copper Tubing (ToLCo Fig. 3F) B3690C - PVC Coated J-Hanger for Pipe or Conduit (Toi-Co Fig. 3PVC) Size Range: 1/2" (15mm) to 10" (250mm) pipe size Material: Steel Function: Recommended for the suspension of non -insulated pipe, or insulated pipe with B3151 shield. Side hole allows for wall mounting. B3690F and B3690C are designed to reduce noise and vibration and/or prevent electrolysis between pipe and hanger. Approvals: Conforms Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 5. Standard Finish: Electro-Plated. Contact B-Line for alternative finishes and materials. Order By: Part number and finish. B369OF A (Rod Size) i Hanger Rod Not Included B3690C B Center of pipe to top of hanger. F Rod Take -Out Center of pipe to bottom of hanger rod. B3690-1/2 Pipe 1/2" O.D. (15) Rod Size 3/8"-16 B 25/8" (66.7) 13/4" C (44.4) D 7/16" (11.1) 11/2" E (38.1) 115/16" F (49.2) Design 400 Load (1.78) Approx. Wt./100 18 (8.1) B3690-3/4 3/4" (20) 3/8"-16 27/8" (73.0) 17/8" (47.6) 7/16" (11.1) 111/16" (42.9) 21/8" (54.0) 400 (1.78) 21 (9.5) B3690-1 1" (25) 3/8"-16 215/16" (74.6) 115/16" (49.2) 7/16" (11.1) 113/16" (46.0) 25/16" (58.7) 400 (1.78) 22 (10.0) B3690-11/4 11/4" (32) 3/8"-16 31/4" (82.5) 2" (50.8) 7/16" (11.1) 21/16" (52.4) 25/8" (66.7) 400 (1.78) 25 (11.3) B3690-11/2 11/2" (40) 3/8"-16 39/16" (90.5) 23/16" (55.6) 7/16" (11.1) 27/16" (61.9) 27/8" (73.0) 400 (1.78) 27 (12.2) B3690-2 2" (50) 3/8"-16 311/16" (93.7) 21/8" (54.0) 7/16" (11.1) 29/16" (65.1) 31/16" (77.8) 400 (1.78) 29 (13.1) B3690-21/2 21/2" (65) 1/2"-13 47/16" (112.7) 27/16" (61.9) 9/16" (14.3) 33/16" (81.0) 35/8" (92.1) 500 (2.22) 64 (29.0) B3690-3 3" (80) 1/2"-13 413/16" (122.2) 29/16" (65.1) 9/16" (14.3) 31/2" (88.9) 41/16" (103.2) 500 (2.22) 72 (32.6) B3690-31/2 31/2" (90) 1/2"-13 51/8" (130.2) 25/8" (66.7) 9/16" (14.3) 33/4" (95.2) 43/8" (111.1) 500 (2.22) 84 (38.1) B3690-4 4" (100) 5/8"-11 61/8" (155.6) 33/16" (81.0) 9/16" (14.3) 45/8" (117.5) 53/16" (131.8) 550 (2.44) 138 (62.6) B3690-5 5" (125) 5/8"-11 63/4" (171.4) 31/4" (82.5) 9/16" (14.3) 51/16" (128.6) 53/4" (146.0) 550 (2.44) 162 (73.5) B3690-6 6" (150) 3/4"-10 73/4" (196.8) 39/16" (90.5) 9/16" (14.3) 513/16" (147.6) 65/8" (168.3) 600 (2.67) 249 (112.9) B3690-8 8" (200) 7/8"-9 93/16" (233.4) 315/16" (100.0) 9/16" (14.3) 615/16" (176.2) 8" (203.3) 760 (3.38) 291 (132.0) B3690-10 10" (250) 7/8"-9 103/4" (273.0) 37/8" (98.4) 9/16" (14.3) 75/8" (193.7) 91/8 (231.8) 760 (3.38) 315 (142.9) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 54 B-Line by E:T■N Pipe Hangers B3109 - Flat Top Clevis Hanger Size Range: 2" (50mm) to 8" (200mm) pipe size Material: Steel Function: Recommended for suspending non - insulated, stationary pipe where space is limited. Approvals: Complies with Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58 Type 1. Standard Finish: Plain or Electro-Galvanized Order By: Part number and finish. A (Rod Size) Hanger Rod Not Included Part B3109-2 ' Rod Size 3/8"-16 B 313/16" B3109-21/2 21/2" (65) 1/2"-13 45/8" (117.5) B3109-3 3" (80) 1/2"-13 55/16" (134.9) B3109-31/2 31/2" (90) 1/2"-13 513/16" (147.6) B3109-4 4" (100) 5/8"-11 61/2" (165.1) B3109-5 5" (125) 5/8"-11 713/16" (198.4) B3109-6 6" (150) 3/4"-10 97/16" (230.2) B3109-8 8" (200) 3/4"-10 113/8" (288.9) 63109-2 25/8" G (66.7) Rod Take 1 7/8" -Out D (47.6) Design Load 300 (1.33) Approx. 52 Wt./100 (23.6) B3109-21/2 33/16" (81.0) 23/16" (55.6) 500 (2.22) 116 (52.6) B3109-3 39/16" (90.5) 25/8" (66.7) 500 (2.22) 133 (60.3) B3109-31/2 313/16" (96.8) 27/8" (73.0) 500 (2.22) 145 (65.8) B3109-4 41/4" (107.9) 31A" (79.4) 700 (3.11) 180 (81.6) B3109-5 5" (127.0) 37/8" (98.4) 700 (3.11) 248 (112.5) B3109-6 511/16" (144.5) 47/16" (112.7) 900 (4.00) 332 (150.6) B3109-8 7" (177.8) 513/16" (147.6) 1000 (4.45) 513 (232.7) B Bottom of pipe to top of hanger. C Center of pipe to top of hanger. D Rod Take -Out Center of pipe to bottom of hanger rod. B-Une by FIT-N All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 55 Pipe Hangers & Supports Pipe Hangers B3106 - Vee Bottom Clevis Hanger JOLCo Fig.1v) Size Range: 112" (15mm) to 4" (loomm) pipe Material: Steel Function: Recommended for the suspension of flexible plastic pipe. Use with B3106V support trough for plastic pipe. Approvals: Complies with Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58 Type 1. Standard Finish: Plain & Elect ro-Galvan ized. Contact B-Line for alternative finishes and materials. Order By: Part number and finish. B3106V - Plastic Pipe Support Channel JOLCO Fig. 1VT) Size Range: 1/2" (15mm) to 4" (100mm) pipe Material: Steel Function: Designed for use with B3106 as a T x Steel support for plastic or other flexible pipe systems. Standard Finish: Pre -Galvanized. Contact B-Line for alternative finishes and materials. Order By: Part number and finish L Size B A (Rod Size) Hanger Rod Not B Overall Height C Center of pipe to top of hanger. D Rod Take -Out Center of pipe to bottom of hanger rod. E Minimum thread length of hanger rod. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 56 B-Line by Ect•N Pipe Hangers B3104 - Light -Duty Clevis Hanger B3104F - Light -Duty Clevis Hanger - Felt Lined B3104C - Light -Duty Clevis Hanger - PVC Coated Size Range: 1/2" (15mm) to 4" (100mm) pipe Material: Steel Function: Recommended for the suspension of light stationary pipe allowing for vertical adjustment. Approvals: Underwriter's Laboratories Listed in the USA (UL) and Canada (cUL) for sizes 3/4" (20mm) thru 4" (1o0mm). Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 12 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 1. Standard Finish: Plain, Electro-Galvanized, or DURA-GREENT" Order By: Part number and finish. A `Slide-RiteTM Clevis Hanger design for sizes 2, 3 & 4. Pat. No. 5,848,770 5,924,655 B3104-1/2 Pipe 1/2" Size (15) Rod 3/8"-16 115/16" (49.2) 11/2" (38.1) B3104-3/4 3/4" (20) 3/8"-16 25/16" (58.7) 13/4" (44.4) B3104-1 1 " (25) 3/8"-16 23/4" (69.8) 21/16" (52.4) B3104-11/4 11/4" (32) 3/8"-16 35/16" (84.1) 27/16" (61.9) B3104-11/2 11/2" (40) 3/8"-16 35/8" (92.1) 25/8" (66.7) B3104-2 * 2" (50) 3/8"-16 413/16" (122.2) 35/8" (92.1) B3104-21/2 21/2" (65) 1/2"-13 513/16" (147.6) 45/16" (109.5) B3104-3 * 3" (80) 1/2"-13 67/16" (163.5) 45/8" (117.5) B3104-31/2 31/2" (90) 1/2"-13 615/16" (176.2) 415/16" (125.4) B3104-4 * 4" (100) 1/2"-13 73/4" (196.8) 51/2" (139.7) Jot C@01 LISTED B Bottom of pipe to top of hanger. C Center of pipe to top of hanger. D Rod Take -Out Center of pipe to bottom of hangerrod. E Minimum thread length of hangerrod. F Adjustment Top of cross bolt to bottom of hanger rod nut inside the hanger. B3104-1/2 •rrLoad 13/16" (20.6) 21/2" (63.5) 7/16" (11.1) 150 (.67) Approx. Wt./100 13 (5.9) B3104-3/4 1" (25.4) 21/2" (63.5) 7/16" (11.1) 250 (1.11) 22 (10.0) B3104-1 13/8" (34.9) 21/2" (63.5) 9/16" (14.3) 250 (1.11) 24 (10.9) B3104-11/4 13/4" (44.4) 21/2" (63.5) 13/16" (20.6) 250 (1.11) 29 (13.1) B3104-11/2 2" (50.8) 21/2" (63.5) 1" (25.4) 250 (1.11) 30 (13.6) B3104-2 * 215/16" (74.6) 21/2" (63.5) 13/4" (44.4) 250 (1.11) 35 (15.9) B3104-21/2 37/16" (87.3) 21/2" (63.5) 2" (50.8) 350 (1.55) 82 (37.2) B3104-3 * 33/4" (95.2) 21/2" (63.5) 2" (50.8) 350 (1.55) 91 (41.3) B3104-31/2 4" (101.6) 21/2" (63.5) 2" (50.8) 350 (1.55) 98 (44.4) B3104-4 * 49/16" (115.9) 21/2" (63.5) 23/16" (55.6) 400 (1.78) 132 (59.9) B3104C B3104F B-Une by E:T-IN All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 57 Pipe Hangers & Supports Pipe Hangers B3104CT - Clevis Hanger (TOLCO Fig. 81) B3104CTC - Clevis Hanger - PVC Coated (TOLCO Fig. 811PVC) Size Range: 1/2" (15mm) to 6" (150mm) copper tubing Material: Steel Function: Recommended for the suspension of non- insulated stationary copper tubing lines. Available with plastic coating to provide additional separation between tubing and hanger. Approvals: Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 12 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 1. I Standard Finish: DURA-COPPERTM Order By: Part number and finish. B3104CTC A B Bottom of pipe to top of hanger. c Center of pipe to top of hanger. D Rod Take -Out Not Center of pipe to bottom of hanger rod. E Minimum thread length of hanger rod. F Adjustment Top of cross bolt to bottom of hanger rod nut inside the hanger. B3104CT B3104CT-1/2 Tubing Size 1/2" (15) Rod Size 3/811-16 21/4" B (57.1) 115/16" C (49.2) Rod Take -Out r 11/8" (28.6) B3104CT-3/4 3/4" (20) 3/8"-16 115/16" (49.2) 11/2" (38.1) 11/8" (28.6) B3104CT-1 ill (25) 3/8"-16 25/16" (58.7) 13/4" (44.4) 15/16" (33.3) B3104CT-1 1/4 11/4" (32) 3/8"-16 23/4" (69.8) 21/16" (52.4) 19/16" (39.7) B3104CT-11/2 11/2" (40) 3/8"-16 35/16" (84.1) 27/16" (61.9) 21/16" (52.4) B3104CT-2 2" (50) 3/8"-16 41/2" (114.3) 37/16" (87.3) 33/8" (85.7) B3104CT-21/2 21/2" (65) 1/2"-13 511/16" (144.5) 41/2" (114.3) 315/16" (100.0) B3104CT-3 3" (80) 1/2"-13 53/16" (131.8) 35/8" (92.1) 4" (101.6) B3104CT-31/2 31/2" (90) 1/2"-13 61/2" (165.1) 49/16" (115.9) 41/8" (104.8) B3104CT-4 4" (100) 1/2"-13 73/8" (187.3) 35/16" (134.9) 43/8" (111.1) B3104CT-5 5" (125) 1/2"-13 9" (228.6) 67/16" (163.5) 53/4" (146.0) B3104CT-6 6" (150) 5/8"-11 105/16" (261.9) 71/4" (184.1) 61/2" (165.1) B3104CT-1/2 21/2" E (63.5) Adjustment F 3/8" (9.5) Design 150 Load (.67) Approx. 12 Wt./100 (5.4) B3104CT-3/4 21/2" (63.5) 7/16" (11.1) 250 (1.11) 12 (5.4) B3104CT-1 21/2" (63.5) 9/16" (14.3) 250 (1.11) 22 (10.0) B3104CT-11/4 21/2" (63.5) 9/16" (14.3) 250 (1.11) 24 (10.9) B3104CT-11/2 21/2" (63.5) 15/16" (23.8) 250 (1.11) 30 (13.6) B3104CT-2 21/2" (63.5) 13/4" (44.4) 250 (1.11) 35 (15.9) B3104CT-21/2 21/2" (63.5) 21/8" (54.0) 350 (1.55) 80 (36.3) B3104CT-3 21/2" (63.5) 21/16" (52.4) 350 (1.55) 88 (39.9) B3104CT-31/2 21/2" (63.5) 21/8" (54.0) 350 (1.55) 94 (42.6) B3104CT-4 21/2" (63.5) 21/8" (54.0) 400 (1.78) 116 (52.6) B3104CT-5 21/2" (63.5) 21/2" (63.5) 550 (2.44) 208 (94.3) B3104CT-6 21le (63.5) 3" (76.2) 550 (2.44) 247 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 58 B-Line by E:T■N Pipe Hangers Fig. 2 - Adjustable Band Hanger (B-Line B3170) ce us A� Fig. 2F - Adjustable Band Hanger Felt Lined for Copper Tubing (B-Line 133170F) LISTED Size Range: Fig. 2 - 21/2" (65mm) thru 6" (150mm) pipe Fig. 2F - 21/2" (65mm) thru 6" (150mm) pipe Material: Pre -Galvanized Steel Function: Recommended for the suspension of non - insulated pipe or insulated pipe with B3151 shield. Fig. 2NFPA accomodates the reduced rod schedule of the National Fire Pretection Association Pamphlet 13. Approvals: Factory Mutual Engineering Approved. Underwriters Laboratories Listed. Conforms to Federal Specification WW-H-171 E & A-A-1192A Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Standard Finish: Pre -Galvanized Note: Available in Stainless Steel material. Order By: Part number and finish. Fig. 2 Fig. 2 Fig. 2F (OTOLC❑ 1� Nominal 2-21/2 Pipe 21/2" Size (65) Rod Size 1/2"-13 * B 53/4" (146.0) 41/4" C (107.9) D 15/8" (41.3) Max. Rec. 600 Load (2.67) App rox 41 Wt./1 00 (18.6) 2-3 3" (75) 1/2"-13 * 6" (152.4) 41/8" (104.8) 11/4" (31.7) 600 (2.67) 45 (20.4) 2-31/2 31/2" (90) 1/2"-13 * 73/8" (187.3) 51/4" (133.3) 21/8" (54.0) 600 (2.67) 52 (23.6) 2-4 4" (100) 5/8"-11 * 73/8" (187.3) 5" (127.0) 15/8" (41.3) 1000 (4.45) 59 (27.6) 2-5 5" (125) 5/8"-11 ** 9" (228.6) 61/8" (155.6) 21/4" (57.1) 1250 (5.56) 97 (44.0) 2-6 6" (150) 3/4"-10 ** 93/8" (238.1) 61/2" (165.1) 17/8" (47.6) 1250 (5.56) 139 (63.0) Fig. 2F Nominal 2F-21/2 Pipe 21/2" Size (65) Rod Size 1/2"-13 * 53/4" B (146.0) 41/4" C (107.9) D 15/8 (41.3) Max. Rec. 600 Load (2.67) Approx 41 Wt./1 00 (18.6) 2F-3 3" (75) 1/2"-13 * 6" (152.4) 41/8" (104.8) 11/4" (31.7) 600 (2.67) 45 (20.4) 2F-31/2 31/2" (90) 1/2"-13 * 73/8" (187.3) 51/4" (133.3) 21/8" (54.0) 600 (2.67) 52 (23.6) 2F-4 4" (100) 5/8"-11 * 73/8" (187.3) 5" (127.0) 15/8" (41.3) 1000 (4.45) 59 (27.6) 2F-5 5" (125) 5/8"-11 ** 9" (228.6) 61/8" (155.6) 21/4" (57.1) 1250 (5.56) 97 (44.0) 2F-6 6" (150) 3/41, -10 ** 93/8" (238.1) 61/2" (165.1) 17/8" (47.6) 1250 (5.56) 139 (63.0) * 3/8 nut is used when requested. ** 1/2 nut is used when requested. B-Line by FffoN All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 59 Pipe Hangers & Supports Pipe Hangers B317OCT - Adjustable Swivel Hanger for Copper Tubing (ToLCo Fig. 202) B317OCTC - Adjustable Swivel Hanger for Copper Tubing - Plastic Coated Size Range: 1/2" (15mm) thru 6" (150mm) copper tubing Material: Steel Function: Recommended for the suspension of B copper tubing, allowing for vertical adjustment. Center of pipe to top of (Available with plastic coating to provide additional knurled hanger rod nut. separation between tubing and hanger.) C Rod Take -Out Approvals: Conforms to Federal Specification Center of pipe to bottom WW-H-171 E & A-A-1192A, Type 10 and Manufacturers of hanger rod. Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Top of pipe to bottom of hanger rod nut. Standard Finish: DURA-COPPERT"' Order By: Part number and finish. Part No. B317OCT-1/2 Nominal • ,. 1/2" (15) Rod Size 3/8"-16 B 21/16" (52.4) 11/8" G (28.6) 31/32 i (24.6) B317OCT-3/4 3/4" (20) 3/8"-16 25/16" (58.7) 15/16" (33.3) 11/32" (26.2) B317OCT-1 1" (25) 3/8"-16 21/2" (63.5) 19/16" (39.7) 15/32" (29.3) B317OCT-11/4 11/4" (32) 3/8"-16 21/2" (63.5) 19/16" (39.7) 1" (25.4) B317OCT-11/2 11/2" (40) 3/8"-16 215/16" (74.6) 2" (50.8) 15/16" (33.3) B317OCT-2 2" (50) 3/8"-16 31/8" (79.4) 21/8" (54.0) 13/16" (30.2) B317OCT-21/2 21/2" (65) 1/2"-13 41/16" (103.2) 29/16" (65.1) 13/8" (34.9) B317OCT-3 3" (75) 1/2"-13 315/16" (100.0) 33/4" (95.2) 11/4" (31.7) B317OCT-31/2 31/2" (90) 1/2"-13 47/16" (112.7) 31/4" (82.5) 11/2" (38.1) B317OCT-4 4" (100) 1/2"-13 411/16" (119.1) 39/16" (89.6) 19/16" (39.7) B317OCT-5 5" (125) 1/2"-13 515/16" (150.8) 45/16" (109.5) 125/32" (45.2) B317OCT-6 1 6" (150) 1/2"-13 611/16" (169.9) 53/16" (131.8) 21/8" (54.0) FM B317OCT-1/2 Max. Rec. 180 Load (0.80) Approx. 8 Wt./100 (6.6) B317OCT-3/4 180 (0.80) 10 (4.5) B317OCT-1 180 (0.80) 10 (4.5) B317OCT-11/4 180 (0.80) 12 (5.4) B317OCT-11/2 180 (0.80) 12 (5.4) B317OCT-2 180 (0.80) 12 (5.4) B317OCT-21/2 200 (0.89) 31 (24.0) B317OCT-3 250 (1.11) 33 (14.9) B317OCT-31/2 300 (1.33) 39 (17.2) B317OCT-4 360 (1.60) 40 (18.1) B317OCT-5 480 (2.13) 95 (43.1) B317OCT-6 630 (2.80) 118 (53.5) B317OCT A (Rod Size) Rod Not uded B317OCTC All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 60 B-Line by E:T■N Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line B317ONF) Fig. 20OF - "Trimline" Adjustable Band Hanger with Felt Lining for Copper Tubing (B-Line B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line B317ONFc) Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe ®TOLCO- C@ Its FM Material: Steel, Pre -Galvanized to G90 specifications LISTED aP•.o� Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: • (1/2" (15mm) thru 2" (5omm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (21/2" (65mm) thru 8" (2oomm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. I' ®/ „ a\\\ B Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (2oomm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" (20mm) thru 8" (200mm)). " Conforms to Federal Specifications WW-H-171 E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Fig. 200-1/2 to 200-2 Fig. 200-21/2 to 200-8 Type 10. Maximum Temperature: 650OF (343°C) Finish: Pre -Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. map Order By: Part number and pipe size ** Note: For metric hanger rod sizes add the VOW -- metric rod size to the figure number. Example: 200M8-11/2 or 200M10-11/2 Fig. 200 Fig. 200C Fig. 20OF 200-1/2 Pipe 1/2" Size (15) Rod 3/8"-16 Size M8 or M10 A 31/8" (79.4) 25/8" B (66.7) Max. Rec. Load 400 (1.78) Approx. 11 Wt./1 00 (5.0) 200-3/4 3/4" (20) 3/8"-16 M8 or M10 31/8" (79.4) 21/2" (63.5) 400 (1.78) 11 (5.0) 200-1 1" (25) 3/8"-16 M8 or M10 33/8" (85.7) 25/8" (66.7) 400 (1.78) 12 (5.5) 200-11/4 11/4" (32) 3/8"-16 M8 or M10 33/4" (94.0) 27/8" (73.0) 400 (1.78) 13 (5.9) 200-11/2 11/2" (40) 3/8"-16 M8 or M10 37/8" (98.4) 27/8" (73.0) 400 (1.78) 14 (6.4) 200-2 2" (50) 3/8"-16 M8 or M10 41/2" (114.3) 3" (76.3) 400 (1.78) 15 (6.9) 200-21/2 21/2" (65) 3/8"-16 M10 55/8" (142.9) 41/8" (104.7) 600 (2.67) 27 (12.3) 200-3 3" (75) 3/8"-16 M10 57/8" (149.1) 4" (101.6) 600 (2.67) 29 (13.3) 200-31/2 31/2" (90) 3/8"-16 M10 73/8" (187.3) 51/4" (133.3) 600 (2.67) 34 (15.6) 200-4 4" (100) 3/8"-16 M10 73/8" (187.3) 5" (127.0) 1000 (4.45) 35 (16.0) 200-5 5" (125) 1/2"-13 M12 91/8" (231.8) 61/4" (158.7) 1250 (5.56) 66 (30.2) 200-6 6" (150) 1/2"13 M12 101/8" (257.2) 63/4" (171.4) 1250 (5.56) 73 (33.4) 200-8 8" 1 (200) 1 1/2"-13 M12 131/8" 1 (333.4) 83/4" (222.2) 1250 (5.56) 136 (62.3) B-Line by FffoN All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 61 Pipe Hangers & Supports Pipe Hangers Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (loomm) trapeze pipe size. Material: Steel — Pre -Galvanized to G40 Spec (DTOLC0 Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used E &us extensively to support trapeze installations and the increased loads LISTED from both above and below the trapeze assembly. Features: Furnished with 3/8"-16 or 1/2"-13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada' (WL). Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650OF (343°C) Finish: Pre -Galvanized Order By: Part number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. -------- ------- TT f ---------- - - - - -- L_J 200H-2-% Pipe 2" Size (50) Rod Size 3/8"-16 49/16" A (115.9) 37/32" B (81.7) Max. Rec. 1200 Load (5.34) Approx. 48 Wt./1 00 (21.8) 200H-2-1/2 2" (50) 1/2"-13 423/32" (119.8) 33/8" (85.7) 1200 (5.34) 45 (20.4) 200H-21/2-% 21/2" (65) 3/8"-16 55/16" (134.9) 323/32" (94.4) 1200 (5.34) 59 (26.7) 200H-21/2-1/2 21/2" (65) 1/2"-13 515/32" (138.9) 37/8" (98.3) 1200 (5.34) 56 (25.4) 200H-3-% 3" (75) 3/8"-16 53/4" (146.0) 327/32" (97.6) 1200 (5.34) 63 (28.6) 200H-3-1/2 3" (75) 1/2"-13 57/8" (148.1) 331/32" (100.8) 1200 (5.34) 60 (27.2) 200H-4-3/8 4" (100) 3/8"-16 67/8" (174.6) 47/16" (112.7) 1200 (5.34) 76 (34.5) 200H-4-1/2 4" (100) 1/2"-13 71/32" 1 (178.6) 1 419/32" 1 (1116.7) 1 1200 1 (5.34) 73 1 (33.1) Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13 (2002) Table 9.1.1.6.1 (a and b). All sizes are UL Listed to support up to 8" pipe at max spacing per NFPA 13. For 6" (15omm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 62 B-Line by E:T■N Pipe Hangers B3198H - Hinged Extension Split Pipe Clamp (ToLCo Fig. 302) Size Range: 3/8" (10mm) to 3" (80mm) pipe Material: Malleable Iron Function: Designed for suspending non -insulated pipe horizontally or vertically. Approvals: Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 25 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 12. Standard Finish: Plain or Electro-Galvanized Order By: Part number and finish. Part No. B3198H-3/8 Pipe in. 3/8" Size (MM) (10) Rod Size A 3/8"-16 C ri-7 (MM) 31/32" (24.6) Design Lbs. 180 Load kN (.80) Approx. Wt./1 00 Lbs. kg 9 (4.1) B3198H-1/2 1/2" (15) 3/8"-16 11/16" (27.0) 180 (.80) 12 (5.4) B3198H-3/4 3/4" (20) 3/8"-16 17/32" (30.9) 180 (.80) 12 (5.4) B3198H-1 B3198H-11/4 1" (25) 3/8"-16 111/32" (34.1) 180 (.80) (.80) 13 (5.9) 18 (8.1) 11/4" (32) 3/8"-16 119/32" (39.7) 180 B3198H-11/2 11/2" (40) 3/8"-16 123/32" (43.6) 180 (.80) 21 (9.5) B3198H-2 2" (50) 3/8"-16 2" (50.8) 180 (.80) 44 (19.9) B3198H-21/2 21/2" (65) 1/2"-13 211/32" (59.5) 300 (1.33) 73 (33.1) B3198H-3 3" (80) 1/2"-13 223/32" (69.0) 300 (1.33) 95 (43.1) B3198R - Extension Split Pipe Clamp Size Range: 3/8" (10mm) to 4" (100mm) pipe Material: Malleable Iron Function: Designed for suspending non -insulated pipe horizontally or vertically. Approvals: Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 25 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 12. Standard Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Part number and finish. Part No. Rod B319811-3/8 Pipe 3/8" Size (10) Rod Thread Size 3/8"-16 31/32" G (24.6) Design 180 Load (.80) Approx. 12 Wt./1100 (5.4) 13319811-1/2 1/2" (15) 3/8"-16 11/16" (27.0) 180 (.80) 16 (7.2) 13319811-3/4 3/4" (20) 3/8"-16 17/32" (30.9) 180 (.80) 18 (8.1) B3198R-1 1" (25) 3/8"-16 111/32" (34.1) 180 (.80) 24 (10.9) 13319811-11/4 11/4" (32) 3/8"-16 119/32" (39.7) 180 (.80) 29 (13.1) B3198R-11/2 11/2" (40) 3/8"-16 123/32" (43.6) 180 (.80) 32 (14.5) B3198R-2 2" (50) 3/8"-16 2" (50.8) 180 (.80) 39 (17.7) B3198R-21/2 21/2" (65) 1/2"-13 211/32" (59.5) 300 (1.33) 115 (52.1) B3198R-3 3" (80) 1/2"-13 223/32" (69.0) 300 (1.33) 140 (63.5) 13319813-4 4" (100) 1/2"-13 311/32" (84.9) 300 (1.33) 160 (72.6) A (Rod Size) Hanger Rod Not Included A - ead Size) er Rod Not cluded B-Une by FIT-N All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 63 Pipe Hangers & Supports Pipe Hangers B3198HCT - Hinged Extension Split Pipe Clamp (ToLCO Fig. 301CT) Size Range: 1/2" (15mm) to 2" (5omm) copper tubing Material: Malleable Iron Function: A rigid support to suspend tubing horizontally or vertically. Approvals: Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 25 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 12. Standard Finish: DURA-COPPERT" Order By: Part number and finish. B3198HCT-1/2 Tubing Size 1/2" (15) Rod Size 3/8"-16 C 5/8" (15.9) Design Load 180 (80) Approx.11 8 (3.6) B3198HCT-3/4 3/4" (20) 3/8"-16 13/16" (20.6) 180 (.80) 10 (4.5) B3198HCT-1 1" (25) 3/8"-16 15/16" (23.8) 180 (.80) 10 (4.5) B3198HCT-11/4 11/4" (32) 3/8"-16 11/8" (28.6) 180 (.80) 14 (6.3) B3198HCT-11/2 11/2" (40) 3/8"-16 19/16" (39.7) 180 (80) 18 (8.1) B3198HCT-2 2" (50) 3/8"-16 17/8" (47.6) 180 (.80) 23 (10.4) B3198RCT - Extension Split Pipe Clamp Size Range: 1/2" (15mm) to 2" (50mm) copper tubing Material: Malleable Iron Function: A rigid support to suspend tubing horizontally or vertically. Approvals: Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 25 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 12. Standard Finish: DURA-COPPERTM Order By: Part number and finish. B3198RCT-3/8 Tubing'id 3/8" (10) Size 3/8"-16 C 11/16" (17.5) Design 180 i.d (.80) Approx. Wt./100 12 (5.4) B3198RCT-1/2 1/2" (15) 3/8"-16 111/16" (17.5) 180 (.80) 12 (5.4) B3198RCT-3/4 3/4" (20) 3/8"-16 7/8" (22.2) 180 (.80) 14 (6.3) B3198RCT-1 1" (25) 3/8"-16 11f16" (27.0) 180 (.80) 17 (7.7) B3198RCT-11/4 11/4" (32) 3/8"-16 11/8" (28.6) 180 (.80) 17 (7.7) B3198RCT-11/2 11/2" (40) 3/8"-16 15/16" (33.3) 180 (.80) 22 (10.0) B3198RCT-2 2" (50) 3/8"-16 11/2" (38.1) 180 (.80) 26 (11.8) A lod Size) anger Rod [Included A .ad Size) ger Rod Included All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 64 B-Line by E:T■N Pipe Hangers B3175 - Ring and Bolt Hanger Size Range: 1/2" (15mm) to 6" (150mm) pipe Material: Pre -Galvanized Steel Function: Designed for suspending light -weight non -insulated pipe. (Use with B3222 eye socket or B3224 hanger adjuster). Standard Finish: Pre -Galvanized Order By: Part number and finish. Bolt and Nut Included size Steel Size B3175-1/2 Pipe 1/2" Size (15) 11/16" C (27.0) :o 1/4"-20 Steel 18 Ga. x 7/8" Size (1.2 x 22.2) Design 275 Load (1.22) Approx. 7.5 Wt./100 (3.4) B3175-3/4 3/4" (20) 13/16" (30.2) 1/4"-20 18 Ga. x 7/8" (1.2 x 22.2) 275 (1.22) 8.0 (3.6) B3175-1 ill (25) 15/16" (33.3) 1/4"-20 18 Ga. x 7/8" (1.2 x 22.2) 275 (1.22) 9.0 (4.1) B3175-11/4 11/4" (32) 11/2" (38.1) 1/4"-20 18 Ga. x 7/8" (1.2 x 22.2) 275 (1.22) 10.5 (4.7) B3175-11/2 11/2" (40) 15/8" (41.3) 1/4"-20 18 Ga. x 7/8" (1.2 x 22.2) 275 (1.22) 11.5 (5.2) B3175-2 2" (50) 113/16" (46.0) 1/4"-20 18 Ga. x 7/8" (1.2 x 22.2) 275 (1.22) 13.0 (5.9) B3175-21/2 21/2" (65) 25/16" (58.7) 5/16"-18 16 Ga. x 11/4" (1.5 x 31.7) 500 (2.22) 30.0 (13.6) B3175-3 3" (80) 25/8" (66.7) 5/16"-18 16 Ga. x 11/4" (1.5 x 31.7) 500 (2.22) 35.0 (15.9) B3175-31/2 31/2" (90) 27/8" (73.0) 5/16"-18 16 Ga. x 11/4" (1.5 x 31.7) 500 (2.22) 38.5 (17.4) B3175-4 4" (100) 31/8" (79.4) 5/16"-18 16 Ga. x 11/4" (1.5 x 31.7) 500 (2.22) 42.0 (19.0) B3175-5 5" (125) 35/8" (92.1) 5/16"-18 16 Ga. x 11/4" (1.5 x 31.7) 500 (2.22) 51.0 (23.1) B3175-6 6" (15o) 43/16" (106.4) 5/16"-18 16 Ga. x 11/4" (1.5 x 31.7) 500 (2.22) 58.5 (26.5) B3175CT - Ring and Bolt Hanger, DURA-COPPERTM Coated Bolt and Nut Included Size Range: 1/2" (15mm) to 4" (100mm) pipe Material: Pre -Galvanized Steel Function: Designed for suspending copper tubing allowing for vertical adjustment. (Use with B3222 eye socket or B3224 hanger adjuster). Standard Finish: DURA-COPPERTM Order By: Part number and finish. sae Steel Size B3175CT-1/2 Tubing Size 1/2" (15) 15/16" C (33.3) :o 1/4"-20 X 1" Steel 1/16" X 7/8" Size (1.6 x 22.2) Design Load 200 (.89) Approx. Wt./100 8 (3.6) B3175CT-3/4 3/4" (20) 13/8" (34.9) 1/4"-20 X 1 " 1/16" X 7/8" (1.6 x 22.2) 200 (.89) 8 (3.6) B3175CT-1 1" (25) 13/16" (30.2) 1/4"-20 x 1" 1/16" x 7/8" (1.6 x 22.2) 200 (.89) 8 (3.6) B3175CT-11/4 11/4" (32) 15/16" (33.3) 1/4"-20 x 1" 1/16" x 7/8" (1.6 x 22.2) 200 (.89) 10 (4.5) B3175CT-11/2 11/2" (40) 11/2" (38.1) 1/4"-20 x 1" 1/16" x 7/8" (1.6 x 22.2) 200 (.89) 11 (5.0) B3175CT-2 2" (50) 115/16" (49.2) 1/4"-20 x 1 " 1/16" x 7/8" (1.6 x 22.2) 200 (.89) 11 (5.0) B3175CT-21/2 21/2" (65) 23/16" (55.6) 1/4"-20 x 1" 1/16" x 7/8" (1.6 x 22.2) 200 (.89) 12 (5.4) B3175CT-3 3" (80) 211/16" (68.3) 1/4"-20 x 1" 1/16" x 7/8" (1.6 x 22.2) 200 (.89) 14 (6.3) B3175CT-31/2 31/2" (90) 215/16" (74.6) 1/4"-20 x 1" 1/16" X 7/8" (1.6 x 22.2) 200 (.89) 16 (7.2) B3175CT-4 4" (too) 33/16" (81.0) 1/4"-20 x 1" 1/16" x 7/8" (1.6 x 22.2) 200 (.89) 18 (8.1) B-Une by E:T-IN All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 65 Pipe Hangers & Supports Pipe Hangers B3190 Return Line Offset J-Hook (TOLco Fig. 40) Size Range: 1/2" (15mm) to 8" (200mm) pipe Material: Steel (Stainless steel available) Function: Recommended for supporting light pipe runs with a 1 " (25.4) offset from mounting surfaces. Standard Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Part number and finish. B3190-1/2 Pipe 1/2" Size (15) Design 200 Load (.89) Approx. 54 Wt./1 00 (24.5) B3190-3/4 3/4" (20) 200 (.89) 55 (24.9) B3190-1 1 " (25) 200 (.89) 78 (35.4) B3190-11/4 11/4" (32) 200 (.89) 85 (38.5) B3190-11/2 11/2" (40) 200 (.89) 90 (40.8) B3190-2 2" (50) 200 (.89) 98 (44.4) B3190-21/2 21/2" (65) 350 (1.55) 126 (57.1) B3190-3 3" (80) 350 (1.55) 136 (61.7) B3190-31/2 31/2" (90) 350 (1.55) 147 (66.8) B3190-4 4" (100) 450 (2.00) 235 (106.6) B3190-5 5" (125) 450 (2.00) 350 (158.7) B3190-6 B3190-8 6" (150) 450 (2.00) 383 (173.7) 8" 1 (200) 1 450 (2.00) 605 (274.4) B3191 Return Line Straight J-Hook (Tosco Fig. 41) 1" (25.4) 9/1611 Dia. (14.3) 5" / (127.0) Size Range: 112" (15mm) to 8" (200mm) pipe Material: Steel (Stainless steel available) Function: Recommended for supporting light pipe runs flush with the mounting surfaces. Standard Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Part number and finish. B3191-1/2 Pipe 1/2" Size (15) Design Load 200 (.89) Approx. 54 Wt./1 00 (24.5) B3191-3/4 3/4" (20) 200 (.89) 55 (24.9) B3191-1 1 " (25) 200 (.89) 76 (34.5) B3191-11/4 11/4" (32) 200 (.89) 82 (37.2) B3191-11/2 11/2" (40) 200 (.89) 87 (39.4) B3191-2 2" (50) 200 (.89) 96 (43.5) B3191-21/2 21/2" (65) 350 (1.55) 124 (56.2) B3191-3 3" (80) 350 (1.55) 134 (60.8) B3191-31/2 31/2" (90) 350 (1.55) 145 (65.8) B3191-4 4" (100) 450 (2.00) 153 (69.4) B3191-5 5" (125) 450 (2.00) 348 (157.8) B3191-6 6" (150) 450 (2.00) 381 (172.8) B3191-8 1 8" 1 (200) 1 450 (2.00) 600 (272.1) 9/16" Dia. (14.3) 5" (127.0) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 66 B-Line by E:T■N Pipe Hangers Fig. 120RWA - (Model B) Retrofit Wrap Around "U" Hanger Clamp Size Range: 1 " (25mm) thru 6" (15omm) pipe Material: Steel Function: Designed to restrain movement of the pipe within standard U-hangers as required by NFPA 13. Where retrofit capability is crucial, the Fig. 120RWA is a labor efficient alternative to the standard Cooper B-Line Fig. 120W wrap around U-hanger. Features Installs easily by tightening two hex nuts. Features a unique bracing slot that locks onto a standard U-hanger to become a solid unit that will stabilize the pipe during seismic activity or sprinkler head activation. Designed to be used in retrofit or new construction applications. Will clamp to existing U-Hangers without restriction to leg angle. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada (cUL) as a restrainer. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the Cooper B-Line Seismic Restraint Systems Guidelines. NFPA 13 (2010) 9.3.6.3. Finish: Plain and Galvanized. Contact B-Line for alternative finishes and materials. Order By: Part number, type numbers and pipe size Ordering Note: Order by the following type and pipe size: Type 1 — (1" (25mm) and 11/4" (32mm) pipe size) Type 2 — (11/2" (40mm) and 2" (50mm) pipe size) Type 3 — (21/2" (65mm) and 3" (80mm) pipe size) Type 4 — (4" (100mm) pipe size) Type 6 — (5" (125mm) and 6" (150mm) pipe size) Important Note: The bracing slot feature is sized to fit the U-Hanger rod schedule as required by NFPA 13 as follows: 5/16" (7.9mm) rod for up to 2" (5omm) pipe 3/8" (9.5mm) rod for 21/2" (65mm) - 6" (160mm) pipe For other rod size requirements consult factory. 120RWA-TYPE1-1 ,.Pipe 1 1 Size 1" (20) 11/4" (25) 120RWA-TYPE1-11/4 120RWA-TYPE2-11/2 2 2 11/2" 2" (40) (50) 120RWA-TYPE2-2 120RWA-TYPE3-21/2 3 21/2" (65) 120RWA-TYPE3-3 3 3" (80) 120RWA-TYPE4-31/2 4 31/2" (90) 120RWA-TYPE4-4 4 4" (100) 120RWA-TYPE6-5 6 5" (125) 120RWA-TYPE6-6 6 6" 1 (150) Component of State of California OSHPD Approved Seismic Restraints System t)TaL.CQ- G &us LISTED B-Line by E:TlN All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 67 Pipe Hangers & Supports Pipe Hangers Fig. 120 - "U" Hanger Size Range: Size 3/4" (20mm) thru 8" (200mm) pipe STD! Material: Steel Function: Used to support piping from wood beams where no contraction is expected. Used extensively in automatic fire sprinkler systems. Approvals: Meets or exceeds the requirements of National Fire Protection Association (NFPA), Pamphlet 13. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the Seismic Restraint Systems Guidelines. Le Maximum Temperature: 750OF (399°C) (Sp Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, pipe size, length and finish 120-3/4 Pipe 3/41, Size (20) A 5/16" (7.9) Fastener Size 16 x 2* Max. Rec. 250 Load*** (1.11) 120-1 1" (25) 5/16" (7.9) 16 x 2* 250 (1.11) 120-11/4 11/4" (32) 5/16" (7.9) 16 x 2* 250 (1.11) 120-11/2 11/2" (40) 5/16" (7.9) 16 x 2* 250 (1.11) 120-2 2" (50) 5/16" (7.9) 16 x 2* 250 (1.11) 120-21/2 21/2" (65) 3/8" (9.5) 3/8 x 21/2** 320 (1.42) 120-3 3" (80) 3/8" (9.5) 3/8 x 21/2** 320 (1.42) 120-31/2 31/2" (90) 3/8" (9.5) 3/8 x 21/2** 560 (2.49) 120-4 4" (100) 3/8" (9.5) 1/2 x 3** 560 (2.49) 120-5 5" (125) 1/2" (12.7) 1/2 x 3** 560 (2.49) 120-6 6" (150) 1/2" (12.7) 1/2 x 3** 760 (3.38) 120-8 8" (200) 1/2" (12.7) 5/8 x 3** -- ( ) " Drive Screw ** Lag Bolt With minimum safety factor of 5 Fastener schedule per NFPA All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 68 B-Line by IFA-N Fig.120MJ - Mutt & Jeff "U" Hanger Size Range: Size 3/4" (20mm) thru 8" (200mm) pipe Material: Steel Function: Used to support piping from wood beams where no contraction is expected. Used extensively in automatic fire sprinkler systems. Fig. 120MJ is used when the wood beam is on a diagonal. Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, side length and finish 120MJ-3/4 Pipe 3/4" Size (20) A 5/16" (7.9) Fastener Size 16 x 2* Max. Rec. 250 Load*** (1.11) 120MJ-1 1" (25) 5/16" (7.9) 16 x 2* 250 (1.11) 120MJ-11/4 11/4" (32) 5h6" (7.9) 16 x 2* 250 (1.11) 120MJ-11/2 11/2" (40) 5h6" (7.9) 16 x 2* 250 (1.11) 120MJ-2 2" (50) 5h6" (7.9) 16 x 2* 250 (1.11) 120MJ-21/2 21/2" (65) 3/8" (9.5) 3/8 x 21/2** 320 (1.42) 120MJ-3 3" (80) 3/8" (9.5) 3/8 x 21/2** 320 (1.42) 120MJ-31/2 31/2" (90) 3/8" (9.5) 3/8 x 21/2** 560 (2.49) 120MJ-4 4" (100) 3/8" (9.5) 1/2 x 3** 560 (2.49) 120MJ-5 5" (125) 1/2" (12.7) 1/2 x 3' 560 (2.49) 120MJ-6 6" (150) 1/2" (12.7) 1/2 x 3** 760 (3.38) 120MJ-8 8" (200) 1 1/2" 1 (12.7) 5/8 x 3' - (--) Fig.120W - Wrap Around "U" Hanger Size Range: Size 3/4" (20mm) thru 2" (50mm) pipe Material: Steel Function: Required for automatic fire protection agencies to be used on the end of branch lines to prevent pipe from whipping vertical and striking ceiling or beam. Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, side length and finish 120W-3/4 Pipe 3/4" Size (20) A 5/16" (7.9) Fastener Size 16 x 2* Max. Rec. 250 Load*** (1.11) 120W-1 1 " (25) 5/16" (7.9) 16 x 2* 250 (1.11) 120W-11/4 11/4" (32) 5/16" (7.9) 16 x 2* 250 (1.11) 120W-11/2 11/2" (40) 5/16" (7.9) 16 x 2* 250 (1.11) 120W-2 1 2" (50) 5/16" (7.9) 16 x 2* 1 250 1 (1.11) Lei (Sp, * Drive Screw ** Lag Bolt *** With minimum safety factor of 5 Fastener schedule per NFPA Lei (Spi * Drive Screw *** With minimum safety factor of 5 Fastener schedule per NFPA Beam Clamps Fig. 65 - Reversible Steel C-Type Beam Clamp 3/411 (19.omm) Throat Opening Fig. 65XT - Reversible Steel C-Type Beam Clamp 3/41, (19.omm) Throat Opening (bottom of page) Size Range: Fig. 65 - 1/2"-13 rod sizes, and 5/8"-11 rod sizes (8)TOLCO Fig. 65XT - 3/8"-16 rod size (see below) Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (19.Omm). Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, 3/8"-16 rod will support 1/2" (15mm) thru 4" (10omm) pipe 1/2"-13 rod will support 112" (15mm) thru 8" (200mm) pipe Included in the Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load spacing and placement information relating OSHPD projects, please refer to the Seismic Restraint System Guidelines. Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number and finish Fig. 65 Patent #4,570,885 Part F Mac Rec. Load * Approx. Wt./100 No. in. (mm) in. (mm) in. (mm) Maximum loads for clamp with set screw in up or down position. Note: See page 27 for recommended setscrew torque. Fig. 65XT-3/8 - Beam Clamp Feature: Extruded holes allow for more thread engagement of threaded rod and set screw. Weight: Approx. Wt./100 - 28.0 Lbs. (12.7kg) Design Load: 730 Lbs (3.25kN) Finish: Plain or Electro-Galvanized Order By: Part number and finish Approvals: Underwriters Laboratories Listed and FM Approved for uo to 4" (100mm) pipe. Component of State of California OSHPD Approved Seismic Restraints System C &us LISTED Set Screw and Locknut Included C @ US (PTOLCO- 11/8.. (28.6) �FMo LISTED JI// 19/16" 5� /1 3/5. y 3/411 (19.0) a��PAN / � � f 7/8" Set Screw and Locknut Included 13/811 (zz.z) (34.9) Note: See page 27 for recommended setscrew torque. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. by E:T*N Line 33 Pipe Hangers & Supports by BULL MOOSE TUBE COMPANY c@us LISTED FM APPROVED no 0NFM NFPA ull Moose Tube° is a customer focused, growth oriented manufacturer and marketer of tubular products, where success is based on a commitment to meeting the customer's perception of quality. Our strength resides in our people working together to satisfy customers and to promote business growth by achieving superior financial performance. www.BuilMooseTube.com sales@bullmoosetube.com 800.325.4467 BULL MOOSE TUBE COMPANY Bull Moose Tube's® "Eddy Pipe®" brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. c@usLISTED FM APPROVED C � UAGM NFPA ADVANTAGES OF BULL MOOSE TUBE° EDDY PIPE° FAMILY • All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual. • Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. • All products are certified to ASTM A135 and A795 Type E, Grade A. • Available in specific cut to order lengths from regular mill rollings. • More popular sizes available with coating or bare. • Ultra Eddy°, Eddy Flow°, Eddylite°, and Eddythread 400 offer cost savings along with superior hydraulics without compromising service life. • Sprinkler pipe inventory stocked in Masury Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent, Washington; and Dallas, Texas. • All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD III MIC preventative coating. • Bull Moose Tube° sprinkler pipe is FBCTM compatible. PRODUCTS • Schedule 10 and Schedule 40: FM approved and UL listed sprinkler pipe. • Eddythread 400: Light threadable Schedule 40 replacement with corrosion resistance ratio of 1.0. • Eddylite°: Lightwall threadable with standard outside diameter. • Eddy Flow®: Cost effective replacement for Schedule 10. • Ultra Eddy®: Lightwall roll groovable pipe. • Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM A123 standards. All products are stencilled to meet FM & UL specifications. PROTECTION • Eddy Guard II®: Bull Moose Tube° is producing product that can resist bacteriological growth even after multiple rinse -outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube® "Eddy Guard II®" and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard II® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull Moose Tube® reserves the right to change product specifications without notice and without incurring obligation. Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM All 23 standards. All products are stencilled to meet FM & UL specifications. c@usLISTED FM APPROVED no 0 N NiFW gµnnw. aa.cevuen E--If7 :1 =1 ■1■], =111110 [a7,1 ;J =IF --I :J =110q I;A -1,4 III [•] 04 E-~ NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.097 15.27 1.41 1bs/ft 1.820 91 1-1/4 1.660 1.442 9.91 1.81 1bs/ft 2.518 61 1-1/2 1.900 1.682 7.76 2.09lbs/ft 3.053 61 2 2.375 2.157 6.27 2.641bs/ft 4.223 37 2-1/2 2.875 2.635 4.92 3.531bs/ft 5.893 30 3 3.500 3.260 3.54 4.34lbs/ft 7.957 19 4 4.500 4.260 2.50 5.62lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68lbs/ft 2.055 70 1-1/4 1.660 1.380 1.00 2.271bs/ft 2.918 51 1-112 1.900 1.610 1.00 2.721bs/ft 3.602 44 2 2.375 2.067 1.00 3.661bs/ft 5.114 30 2-1/2* 2.875 2.468 1.00 5.801bs/ft 7.875 30 3* 3.500 3.068 1.00 7.581bs/ft 10.783 19 4* 4.500 4.026 1.00 10.801bs/ft 16.316 19 *Only available in Casa Grande, AZ **Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak -tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ° For Additional Information Contact (800) 325-4467 www.builmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masur , OH 61JLL MCCSE Tu6ECCMpa y 63017 S] U t 4 Bull Moose Tube's° Eddythread 40® ADVANTAGES OF BULL MOOSE TUBE° EDDYTHREAD 400 is a lightweight replacement for • Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion • Has a pressure rating of 300 psi. Resistance Ratio of 1. • Is lighter weight than Schedule 40. • Is approved by Factory Mutual and listed by Underwriters Laboratories. • Is produced in accordance to ASTM A135 and A795 Type E, Grade A. • Can be used with standard Schedule 40 threaded fittings, couplings, and valves. • Is produced from steel with excellent properties of strength and threadability. • Can be used in wet, preaction, and deluge type sprinkler systems. • Can be hot dipped galvanized to meet FM's requirement for dry systems. • Offers lower freight costs. • Supplied with EDDY GUARD III MIC preventative coating. c@usLISTED FM APPROVED no A ova NiFW gµnnw. aa.cevuen EDDYTHREAD 40" SPECIFICATIONS NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR* LB./FT WEIGHT SIZE 1 1.295 1.083 1.00 1.461 1.860 70 1-1/4 1.650 1.418 1.00 2.070 2.754 51 1-1/2 1.900 1.654 1.00 2.547 3.468 44 2 2.375 2.123 1.00 3.308 4.842 30 'Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak -tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ° For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas,TX Masury, OH HULL MOO! IE COMPANY 63017 5 Page 1 of 6 ® MICROFAST° QUICK 4 I KjRESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION The Viking MicrofaW Quick Response Pendent Sprinkler VK302 is a small thermo- sensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 vds VdS Approved: Certificates G414009 and G414010 LPCB LPCB Approved C E CE Certified: Standard EN 12259-1:1999, A3:2006 Certificate of Constancy of Performance 0832-CPR-SO021 «<` CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass -bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) *Wl_us Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-Cl1000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring -Exposed For ENT Coated Sprinklers: Belleville Spring -Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Form No. F_033314 17.10.05 Rev 17.2 Replaces Form No. F_033314 Rev 17.1 (Replaced wrench 10896W/B with 21475M/B) Page 2 of 6 ® MICROFAST° QUICK 4 I KjRESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Wrenches: A. Standard Wrench: Part No. 21475M/B (available since 2017). B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A %" ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of V diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: A. Six -head capacity: Part No. 01724A (available since 1971) B. Twelve -head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat -sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast° Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Protective Sprinkler Cap Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_033314 17.10.05 Rev 17.2 Page 3 of 6 ® MICROFAST° QUICK 4 I KjRESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion -Resistant Coatings3: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion -resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Sprinkler wrench 13655W/B** for recessed pendent sprinklers ** A 1/2" ratchet is required (not available from Viking) H Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 17.10.05 Rev 17.2 Page 4 of 6 ® MICROFAST° QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 1 (UL) The Viking Microfast° Quick Response Temperature KEY Pendent Sprinkler VK302 .� Finish p Al X F Escutcheon (if applicable) Maximum 175 PSI (12 Bar) WWP Base Sprinkler Thread Size Nominal Overall Listings and Approvals' Part SIN Style K-Factor Length (Refer also to Design Criteria.) Number NPT I BSP U.S. metric, Inches mm cULus° VdS LPCB 7 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X Al A1Z, B1Y D1Z, C1Y 19780 VK302 Pendent 1/2" 5.6 80.6 2-1/4 58 D3 21354 VK302 Pendent -- 15 mm 5.6 80.6 2-1/4 58 D3 NOTICEOffice) 06662B VK302 Pendent 1/2" mm 5.6 80.6 2-1/4 58 A1Z,B1YD2,C2X 18021 VK302 Pendent 1/2"[V5 15 mm 5.6 80.6 2-1/4 58 A1X, B1Y Al A1X, B1Y D1X, C1Y8 D1X, C1Y9 Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135 OF (57 °C), 155 OF (68 °C), 175 OF 1 - Brass, Chrome, White X - Standard surface -mounted escutcheon or the (79 °C), 200 OF (93 °C), 286 OF (141 °C) Polyester5', Black Polyes- Viking Micromatic® Model E-1 Recessed Escutcheon B - 135 OF (57 °C), 155 OF (68 °C), 175 OF terns Y - Standard surface -mounted escutcheon or the (79 °C), and 200 OF (93 °C) 2 - ENT' Viking Microfast° Model F-1 Adjustable Escutcheon, or recessed with the Viking Micro- C - 155 OF (68 °C), 175 OF (79 °C), and 3 - Chrome mati& Model E-1, E-2, or E-3 Recessed Escutcheon 200 OF (93 °C) Z - Standard surface -mounted escutcheon or the D - 155 OF (68 °C), 175 OF (79 °C), 200 OF Viking Microfast° Model F-1 Adjustable Escutcheon (93 °C), 286 OF (141 °C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. , Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. ° Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. s cULus Listed as corrosion -resistant. s Other colors are available on request with the same Listings and Approvals as the standard colors. 7 CE Certified, Standard EN 12259-1, EC -certificate of conformity 0832-CPD-2001. 8 CE Certified, Standard EN 12259-1, EC -certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. 9 MED Certified, Standard EN 12259-1, EC -certificates of conformity 0832-MED-1003 and 0832-MED-1008. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast° Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan- dards, whenever applicable. Form No. F_033314 17.10.05 Rev 17.2 Page 5 of 6 ® MICROFAST° QUICK 4 I KJ RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY The Viking Microfast® Quick Response Finish Pendent Sprinkler VK302 A1XF Escutcheon (if applicable) Maximum 175 PSI (12 Bar) WWP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' Number' SIN Style (Refer also to Design Criteria.) NPT BSP U.S. metric2 Inches mm 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 1 58 A1Z, B1Y, D2X, C2 ProductNOTICE - 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1/2" 15 mm 1 5.6 80.6 2-1/4 58 1 A1Z, B1Y Approved Escutcheons Approved Temperature Ratings X - Standard surface -mounted escutcheon or the A- 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F Viking Micromatic° Model E-1 Recessed (93 °C), 286 °F (141 °C) Approved Finishes Escutcheon B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 1 - Brass, Chrome, White Polyester°, Y - Standard surface -mounted escutcheon or the 200 °F (93 °C) and Black Polyester° Viking Microfast° Model F-1 Adjustable Escutcheon, C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 2 - ENT5 or recessed with the Viking Micromatic° Model E-1 °F (141 °C) or E-2 Recessed Escutcheon D - 155 °F (68 °C), 175 °F (79 -C), 200 °F (93 °C) Z - Standard surface -mounted escutcheon or the Viking Microfast° Model F-1 Adjustable Escutcheon Footnotes ' Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Other approvals may be in process. ° Other colors are available on request with the same Approvals as the standard colors. 5 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: The Viking Microfast° Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non -storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 17.10.05 Rev 17.2 Page 6 of 6 N4 I Ki® MICROFAST° QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1 /2" (15 mm) NPT` 2-1/4" (57 mm) Installed with a standard 1/8" surface -mounted escutcheon W Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum 2-1/8" (54 mm) T 1-1 /2" 2" (38 mm) (51 mm) Min. Max. Installed with a Microfast Note: At maximum, adapter Model F-1 Adjustable is exposed 1/2" (13 mm) Escutcheon from face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Ceiling Opening Size: 2-5/16" (59 mm) minimum It 2-1/2" (64 mm) maximum 2-1/8" 2-1/8" (54 mm) (54 mm) 1-1/8" T i 1-1/8„ 1-3/4" (29 mm) 2,,,, (29 mm) (45 mm) Min. (51 mm) Min. Max. Max. Installed with a Model E-1 Recessed Escutcheon Installed with a Model E-2 Thread -on Recessed Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 17.10.05 Rev 17.2 Replaces Form No. F_033314 Rev 17.1 (Replaced wrench 10896W/B with 21475M/B) no P e drequnged Product Features • Made with Teks® self -drilling fasteners - no pre -drilling required. • Install into steel range from 22 gauge —1/2" thicknesses. • Saves time from traditional methods. • Reduces installation cost. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Approvals Size Part Number Model Screw DescriptionsRod Ultimate UL Test I'M Test Min Max Box Case 114" 8024957 DSTR 100 * 1/4-20 x 1"TEKS 3 1510 (20 ga.) .036"-20 ga 3116" 25 125 1/4" 8025957 DST 100 1/4-14 x 1" TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 1/4" 8026957 DST 150 1/4-14 x 1-1/2" TEKS 3 970 (16 ga.) .036"-20 ga 3/16" 25 125 1/4" 8027957 DST 200 1/4-14 x 2" TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 1/4" 8030957 TEK 500 12-24 x 1-1/2" TEKS 5 3125 (3/16") .187"-3/16" 1/2" 25 125 ° , 0 3/8" 8038957 DSTR 1 * 1/4-20 x 1" TEKS 3 1510 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 3/8" 8037957 DSTR 1-1/2 * 12-24 x 1-1/2" TEKS 5 1510 (3/16") 1500 1475 .060"-16 ga. 1/2" 25 125 D. 0 3/8" 8039957 DSTR 516 * 5/16-18 x 1-1/4" TEKS 3 2200 (20 ga.) 1500 1475 .036"-20 ga 1/8" 25 125 3/8" 8040957 DST 10 1/4-14 x 1" TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 #14 Black 970 (16 ga.) Nut Driver Part # 8113910 3/8" 8077925 DST 10-SS 114-14 x 1"TEKS 3 446 (20 ga.) 036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8041957 DST 15 1/4-14 x 1-1/2" TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8078925 DST 15-SS 1/4-14 x 1-1/2" TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8042957 DST 20 1/4-14 x 2 TEKS" 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8043957 DST 25 1/4-14 x 2-1/2" TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8044957 DST 30 1/4-14 x 3" TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8045957 DST516 5/16-18 x 1-1 /4" TEKS 3 1500 (3/16") 1500 1475 .125"-1/8" 1/8" 25 125 O 3/8" 8046957 TEK 50 12-24 x 1-112" TEKS 5 3125 (3/16") 1500 1475 .187"-3/16" 1/2" 25 125 1/2" 8031925 DST 2.0 1/4-14 x 2" TEKS 3 446 (20 ga.) 1/4" 25 125 970 (16 ga.) .188"-3/16" 1/2" 8033925 DSTR 1.0 * 1/4-20 x 1"TEKS 3 1510 (20 ga.) .036"-20 ga 3/16" 25 125 1/2" 8034925 DSTR 5.16 * 5/16-18 x 1-1/4" TEKS 3 2220 (20 ga.) .036"-20 ga 1/8" 25 125 1/2" 8035925 DST 5.16 5/16-18 x 1-114" TEKS 3 1500 (3116") .125"-1/8" 1/8" 25 125 1/2" 8036925 TEK 5.0 12-24 x 1-1/2" TEKS 5 3125 (3/16") .187"-3/16" 1/2" 25 125 #14 SW Red Nut Driver *Includes retaining nut Part # 8114910 }Approvals Rod Part Model Screw Ultimate UL Test I'M Test Min Max Box Case size Number Descriptions Pullout 3/8" 8137957 SH-DSTR 1 * 1/4-20 x 1" 3220(3/16") 1500 1475 .035" 3116" 1 25 125 } }I I` *Includes retaining nut (Does not comply with ROHS requirements) #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into Part # 8113910 contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Upper Attachments B3199R - Ceiling Flange B3199RCT - Ceiling Flange Dura-Copper Coated B Overall H Size Range: 3/8"-16 & 1/2"-13 rod Material: Malleable Iron (Stainless Steel Type 304 available) For 1/4" Flat Head Standard Finish: Plain or Electro-Galvanized Machine screws B3199RCT is DURA-COPPER" coated or wood Screws Function: Designed for attaching a hanger or support rod to beams, ceilings, or walls. Order By: Part number and finish. B3199RCT B3199R Fig. 78 - All Steel Ceiling Plate (8)TOLCO- Size Range: 3/8"-16 rod Material: Pre -Galvanized Steel Function: Attachment to wood beams, ceilings, metal decks or walls. Can also be welded to steel beams. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Additionally, UL has listed the Fig. 78 with fasteners as shown in the table below. Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, rod size and finish c&US US Patent #5,702,077 LISTED UL Listed Fastener Table Pipe Size Qty Fastener Type Material 1/2" - 2" 2 #14 x 11/4" A -point hex -washer -head sheet metal screw Wood 21/2" - 4" 2 1/4" x 11/2" wood screws* Wood 1/2" - 2" 2 1/4" x 1 " tek screws Metal (18 gauge) 1/2" - 2" 2 #14 x 11/4" A -point hex -washer -head sheet metal screw Wood 1/2" - 2" 2 #14 x 2" A- point- hex -washer -head sheet metal screw Wood thru 5/8" gyp board * No pre -drilling (Rod or Pipe Thread) Hanger Rod or Pipe Not Included D (2 Holes) i a All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 214 B-Line by E.Z•N Cast Iron CAST IRON THREADED FITTINGS - CLASS 125 (STANDARD) Fig. 351 90" Elbow Size Range:'/4" thru 8" Page 37 IV Fig. 358 Tee Size Range:'/4" thru 8" Page 40 Fig. 487 Flanged Union Gasket Type Size Range:'h" thru 8" Page 46 Fig. 387 Square Head Plugs, Cored Size Range: 3/4" thru 4" Page 51 46 Fig. 371 90' Elbow - Flange & Screw Size Range: 21/2" thru 6" Page 37 %I Fig. 359 Reducing Tee Size Range: 1/2" x'/2" x'/4" thru 6" x 6" x 5" Page 40 - 44 Fig. 367 Concentric Reducer Size Range: 3/4" x'/2" thru 8" x 6" Page 47 Fig. 388 Square Head Plugs, Solid Size Range:'/2" thru 31/2" Page 51 0 1 C20 Fig.381 Fig.370 Cap Locknut I Size Range: 21/2" thru 8" Size Range: 21/2" thru 4" Page 51 Page 52 *9 Fig. 356 & 356R 45' Elbow (Straight & Reducing) Size Range: 1/4" thru 8" (Straight) 1" x'/2" (Reducing) Page 38 IF Fig. 360 Cross Size Range:'/2" thru 6" Page 45 Fig. 368 Eccentric Reducer Size Range: 3/4" x'/2" thru 6" x 4" Page 48 fb Fig. 389 Bar Plugs, Cored Size Range: 4" thru 8" Page 51 91 Fig. 356A 221/2" Elbow Size Range: 3/4" thru 21/2" Page 38 it Fig. 361 Cross Reducing Size Range: 1"x1"x3/4"x3/4"thru 4"x4"x2"x2" Page 45 fe Fig. 383 Hex Bushing Size Range: 11/2" x'/4" thru 10" x 8" Page 49 - 50 to Fig. 380 Bar Plugs, Solid Size Range: 4" thru 8" Page 51 IN Fig. 352 90" Reducing Elbow Size Range: 1/2" x'/4" thru 6" x 5" Page 39 0 Fig. 366 Screwed Hex Coupling Size:1 " Page 46 Fig. 385 Face Bushing Size Range: 3" x 2" thru 4" x 3" Page 50 Fig. 390 Countersunk Plugs Size Range: 1" thru 4" Page 51 CAST IRON THREADED FITTINGS - CLASS 250 (EXTRA HEAVY) Fig. 421 Fig. 424 Fig. 425 Fig. 426 90' Elbow 45' Elbow Tee Reducing Tee Size Range:'/4" thru 3" Size Range:'/2" thru 21/2" Size Range: 1/4" thru 4" Size Range: 3/4" x 3/4" x'/2" thru 2" x 2" x 1112" Page 52 Page 52 Page 53 Page 53 ANVIL PF-11.13 Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line B317ONF) Fig. 20OF - "Trimline" Adjustable Band Hanger with Felt Lining for Copper Tubing (B-Line B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line B317ONFc) Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe ®TOLC❑ C@ us <FM Material: Steel, Pre -Galvanized to G90 specifications LISTED aP•.o� Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: • (1/2" (15mm) thru 2" (5omm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in ® B hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (2oomm)) %' a in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" (20mm) thru 8" (200mm)). " Conforms to Federal Specifications WW-H-171 E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Fig. 200-1/2 to 200-2 Fig. 200-21/2 to 200-8 Type 10. Maximum Temperature: 650OF (343°C) Finish: Pre -Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. map Order By: Part number and pipe size ** Note: For metric hanger rod sizes add the VOW -- metric rod size to the figure number. Example: 200M8-11/2 or 200M10-11/2 Fig. 200 Fig. 200C Fig. 20OF 200-1/2 Pipe 1/2" Size (15) Rod 3/8"-16 Size M8 or M10 A 31/8" (79.4) 25/8" B (66.7) Max. Rec. Load 400 (1.78) Approx. 11 Wt./1 00 (5.0) 200-3/4 3/4" (20) 3/8"-16 M8 or M10 31/8" (79.4) 21/2" (63.5) 400 (1.78) 11 (5.0) 200-1 1" (25) 3/8"-16 M8 or M10 33/8" (85.7) 25/8" (66.7) 400 (1.78) 12 (5.5) 200-11/4 11/4" (32) 3/8"-16 M8 or M10 33/4" (94.0) 27/8" (73.0) 400 (1.78) 13 (5.9) 200-11/2 11/2" (40) 3/8"-16 M8 or M10 37/8" (98.4) 27/8" (73.0) 400 (1.78) 14 (6.4) 200-2 2" (50) 3/8"-16 M8 or M10 41/2" (114.3) 3" (76.3) 400 (1.78) 15 (6.9) 200-21/2 21/2" (65) 3/8"-16 M10 55/8" (142.9) 41/8" (104.7) 600 (2.67) 27 (12.3) 200-3 3" (75) 3/8"-16 M10 57/8" (149.1) 4" (101.6) 600 (2.67) 29 (13.3) 200-31/2 31/2" (90) 3/8"-16 M10 73/8" (187.3) 51/4" (133.3) 600 (2.67) 34 (15.6) 200-4 4" (100) 3/8"-16 M10 73/8" (187.3) 5" (127.0) 1000 (4.45) 35 (16.0) 200-5 5" (125) 1/2"-13 M12 91/8" (231.8) 61/4" (158.7) 1250 (5.56) 66 (30.2) 200-6 6" (150) 1/2"13 M12 101/8" (257.2) 63/4" (171.4) 1250 (5.56) 73 (33.4) 200-8 8" 1 (200) 1 1/2"-13 M12 131/8" 1 (333.4) 83/4" (222.2) 1250 (5.56) 136 (62.3) B-Line by E.T•N All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 61 Pipe Hangers & Supports CAL FIRE - RIVERSIDE UNIT RIVERSIDE COUNTY FIRE DEPARTMENT OFFICE OF THE FIRE MARSHAL — LA QUINTA CALIFORNIA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org April 22, 2022 World Fire Protection INC 41905 Boardwalk Suite B Palm Desert, CA 92211 Re: TI Fire Sprinkler Plan Review — Dr. HSU FSS2022-0103 / 79215 CORPORATE CENTRE DR #120, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. The following inspections/tests are required to be witnessed by the Office of the Fire Marshal staff: 1) Overhead Rough: All installed/relocated piping must be visible. 2) Final inspection: All trim is in place, 5-Year certification is current. New/added heads shall be included in the spare head box compliment. *Water -flow signal test may be performed during the Final Inspection. All persons performing work on the automatic fire sprinkler system shall be Certified Sprinkler Fitters or Registered with the State Fire Marshal for Apprentice or Trainee classification. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist i6RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD ai�Cv uGKCv THIS CARD IS TO REMAIN ON SITE AT ALL TIMES.—CALIFORNIA— INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 79215 CORPORATE CTR DR #120 PERMIT#: FSS2022-0103 AT ED: 4/22/2022 DESCRIPTION: DR HSU CONTRACTOR: WORLD FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre -pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final IF Deluge/pre-action SPRINKLER U.G. Final EF Thrust block pre -pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final IF Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors' test Hood/duct extinguishing High pile storage High pile rack storage In -rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final e F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final e F FIRE ALARM KNOX SYSTEM Rough -wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final F' Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE- 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE -INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131