FSS2022-0103Description: TI OF EXISTING NFPA 13 SYSTEM
Type: FIRE SPRINKLER (WEB)
Subtype:
Status: FINALED
Applied: 3/22/2022 ECON
COMMERCIAL/INDUSTRIAL
Approved: 4/22/2022 KHET
Parcel No: 600390017 Site Address: 79215 CORPORATE CENTRE DR STE 120 LA QUINTA,CA
92253
Subdivision: PM 29351
Block:
Lot: 7
Issued: ONLINE
Lot Sq Ft: 0
Building Sq Ft: 0
Zoning:
Finaled: 5/31/2022 KHET
Valuation: $6,500.00
Occupancy Type:
Construction Type:
Expired:
No. Buildings: 0
No. Stories: 0
No. Unites: 0
Details: TI of existing system for new Dr. Office
ADDITIONAL
CHRONOLOGY
•
NAME TYPE
NAME
ADDRESSI
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
WORLD FIRE PROTECTION INC
41-905 BOARDWALK
STE B
PALM DESERT
CA
92211
(760)565-6030
bchapman@worldfirep
rotection.com
CONTRACTOR
World Fire Protection
41905 Boardwalk Suite
B
Palm Desert
CA
92211
(760)565-6030
bchapman@worldfirep
rotection.com
OWNER
BLOOD BANK OF SAN BERNARDINO
PO BOX 1429
SAN
BERNARDINO
CA
92253
(760)565-6030
Printed: Wednesday, April 05, 2023 2:37:45 PM 1 of 4
WsYsrEMS
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CLTD
BY
FIRE SPRINKLER
SYSTEMS - TENANT
101-0000-42420
0
$167.00
$167.00
5/11/22
WEB11706
637109882
CREDIT
1049720
ECON
IMPROVEMENT OVER
15
10 HEADS
FIRE SPRINKLER
SYSTEMS - TENANT
101-0000-42420
0
$333.00
$333.00
5/11/22
WEB11706
637109882
CREDIT
1049720
ECON
IMPROVEMENT OVER
15
10 HEADS PC
Total Paid for FIRE FEES: $500.00 $500.00
RECORDS
101-0000-42416
0
$11.00
$11.00
5/11/22
WEB11706
637109882
CREDIT
1049720
ECON
MANAGEMENT FEE
15
Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00
TECHNOLOGY
502-0000-43611
0
$5.00
$5.00
5/11/22
WEB11706
637109882
CREDIT
1049720
ECON
ENHANCEMENT FEE
15
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
. 00 $516.00
SEQID
INSPECTION TYPE
INSPECTOR
SCHEDULED
DATE
COMPLETED
DATE
RESULT
REMARKS
NOTES
Printed: Wednesday, April 05, 2023 2:37:45 PM
2 of 4
CRWSY5TEM5
FIRE INSPECTOR I KHET I I I DISAPPROVE
OVERHEAD ROUGH KHET 5/18/2022 5/18/2022 APPROVED
PIPING
FIRE FINAL" LIN 5/31/2022 1 5/31/2022 1 APPROVED
PARENT PROJECTS
Performed impromptu inspection at the
project location to evaluate World Fire
Protection compliance with previous
warnings associated with performing work
prior to permit issuance and work
performed by uncertified Fire Sprinkler
Fitters. Met GC Superintendent Josh and
confirmed that work was performed on
Thursday or Friday 4/21 or 4/22. Josh gave
tour of the work performed and I observed
items of concern, including no coupon
recovery, improper hanger attachments and
un-proposed/permitted flex drop
installation. Asked Josh to request from
World Fire Protection a list of individuals
that performed work on this project
location.
LQ OFM will consider appropriate
enforcement.
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
RETURNED
DATE
STATUS
REMARKS
NOTES
1ST FIRE - ETRAKIT
KOHL
3/22/2022
4/5/2022
4/22/2022
APPROVED
SEE ATTACHMENTS
(2 WK)
HETRICK
1ST PERMIT TECH —
PERMIT TECH
3/22/2022
3/23/2022
3/23/2022
COMPLETE
ETRAKIT (1 DAY)
BUCKET
Printed: Wednesday, April 05, 2023 2:37:45 PM 3 of 4
WsYsrEMS
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
3/22/2022
Etrakit Contractor
1ST SUBMITTALSIDEWINDERS
Sammy STEEL SIDE.pdf
1
DOC
3/22/2022
Etrakit Contractor
1ST SUBMITTAL VK302
VIKING QR SEMI PEND
1
VK302.pdf
DOC
3/22/2022
Etrakit Contractor
1ST SUBMITTAL PIPING
DR HSU TI PIPING FS-
1
PLAN
1.pdf
DOC
3/22/2022
Etrakit Contractor
1ST SUBMITTAL PIPE
BULLMOOSE PIPE.pdf
1
DOC
3/22/2022
Etrakit Contractor
1ST SUBMITTAL CLAMP
FIG 65 C CLAMP.pdf
1
1ST SUBMITTAL PIPE
DOC
3/22/2022
Etrakit Contractor
HANGERS AND
FIG 69 RETAINING
1
STRAP.pdf
SUPPORT
DOC
3/22/2022
Etrakit Contractor
1ST SUBMITTAL FLANGE
FIG 78 CEILING FLG.pdf
1
DOC
3/22/2022
Etrakit Contractor
1ST SUBMITTAL PIPE
FIG 200 RING.pdf
1
HANGERS
DOC
3/22/2022
Etrakit Contractor
1ST SUBMITTAL PIPEFITTINGS
MI Pipe_Fittings.pdf
1
DOC
3/22/2022
Etrakit Contractor
1ST SUBMITTAL
Sammy STEEL
1
VERTICAL MOUNT
BOTTOM.pdf
DOC
4/22/2022
KOHL HETRICK
FSS2022-0103 -
FSS2022-0103 -
1
APPROVED PLANS.pdf
APPROVED PLANS.pdf
DOC
4/26/2022
KOHL HETRICK
FSS2022-0103 - COA
FSS2022-0103 - COA
1
AND JOB CARD.pdf
AND JOB CARD.pdf
Printed: Wednesday, April 05, 2023 2:37:45 PM 4 of 4
WsYsrEMS
.rxom <axo ..a Ro
' xar/ cxR. m
xis ARM-0VER DETAIL
BREAK ROOM
�611
I uu
1
1
1
1
E
'® ccNc N mox
a� ripEau �uA mu x xr
ecnu fox yrEL ox co,eu. xoai OI
a/a- A�� TxR.o Roo
xo mox
15- MEM NG TG STEEL FRAMING 16
Pl HANGER To METAL pE x1NG
FTA
9 �T
LEGEND
o
r-alTipmu
w. ill
wommmommmom.
■nmmnmmmm
I I 1
I
I 1
E,♦ I o I OE
1
I I 1
a, o ,
DATA
VITALS 2
IEO ENDEN
TO REMAM NO D'
CHANGES MENS D' ,®
j� ITALS 1 '® WOMANS
E,
SOL
III ElIXIYE111 F1-3i■�a 1 m1i1■■L---'_ °INE34
■h�L7■1ili��nn f■!I■■1
■■MO I �• ■0■ I■■1
-- = i mmmml I�■■ii■ ■■■■■ .... ■■■■■■■■■1
-- 0101301 1II■120®®1 11■■■■1, i��l l�i■■■■■■■■1
j■■!■■ ®RFMAI I■■■■■■■■■■1 ]
■Gl■■'L■Ci■II■ �� G■■■■■■■■■►
�_ , ■�■■■!�■■ I® NONE■■■■■■■■■■■1
�, ■[':III■�■■Cr�■■F
i�� �?�■..l III■■; 111 ■■■■■■II■■11—I■■■0_■■■■1
1 1 TO BOTTOM
SCOPE —
KEY PLAN SUITE 120
, SITE
Wr VICINITY MAP
PROJECT IAFORJ.ATIOA
APPLICABLE CODES
PROJECT DESCR
PROJECT T.I. NOTE
i
La Quinta Office of the Fire Marshal
BY: Kohl Hetrick^ "b> ,o`
FIRE SAFETY SPECIALIST
04/22/2022 4:32:05 PM
The approval of plans and specifications does no[
permit the violation, deletion, omission or faulty
installation of any requirements of Title 24 or any
Local Ordinances. Construdion shall remain
ssible anse d expod for inspection purposes
until app..d by the Fire Department.
CD
z8
�= z
QL�s z
Lj
Z U m o
�N W<aAi
L'i_
= O 0 ry m
NORTH
DRAWING NO. FN3-1 33
#14 SW Red
Nut Driver
Part # 8114910
no
pr e-dr�ulrged
Product Features
• Made with Teks® self -drilling fasteners - no pre -drilling required.
• Install into steel range from 22 gauge —1/2" thicknesses.
• Saves time from traditional methods.
• Reduces installation cost.
• Quick to install using the Sammy Nut Driver with an 18V
cordless drill/driver.
1/4"
8047957 SWD 100
1/4-14 x 1"TEKS 3
1477 (16 ga.)
.060"-16 ga
3116"
25
125
1/4"
8049957 SWDR 100 *
1/4-20 x 1"TEKS 3
1900 (20 ga.)
.036"-20 ga
3/16"
25
125
3/8"
8050957 SWD 10
1/4-14 x 1"TEKS 3
1477 (16 ga.)
.060"-16 ga
3/16"
25
125
3/8"
8080925 SWD 10-SS
1/4-14 x 1" TEKS 3
1477 (16 ga.)
.060"-16 ga
3/16"
25
125
3/8"
8051957 SWD 15
1/4-14 x 1-112" TEKS 3
1477 (16 ga.)
.060"-16 ga
3/16"
25
125
3/8"
8081925 SWD 15-SS
1/4-14 x 1-112" TEKS 3
1477 (16 ga.)
.060"-16 ga
3/16"
25
125
3/8"
8052957 SWD 20
1/4-14 x 2" TEKS 3
1477 (16 ga.)
.060"-16 ga
3/16"
25
125
3/8"
8053957 SWD 516
5/16-18 x 1-1/4" TEKS 3
2480 (20 ga.)
.036"-20 ga
1/8"
25
125
eO
3/8"
8055957 SWDR 1 *
1/4-20 x 1"TEKS 3
1900 (20 ga.)
1500 1475 .036"-20 ga
3/16"
25
125
3/8"
8054957 SWDR 1-1/2 *
12-24 x 1-1/2" TEKS 5
2375 (3/16")
1500 1475 .187"-3/16"
1/2"
25
125
Q
3/8"
8056957 SWDR 516 *
5/16-18 x 1-1/4" TEKS 3
2480 (20 ga.)
1500 1475 .036"-20 ga
1/8"
25
125
3/8"
8057957 SWT 15
12-24 x 1-1/2" TEKS 5
237 (3/16")
.187"-3/16"
1/2"
25
125
*Includes retaining nut
Performance Data - Steel
Gauge No.
26
24
22 20
18
16 14
12
3116"
114"
Nominal Decimal Equivalent
.018
.024
.030 .036
.048
.060 .075
.105
1 .188
1 .250
Ultimate Pullout
Fastener
Values (avg. lb MYS
Steel Gauge (lbs.)
Model
Dia.
Pt.
20
18
16
14
12
3116
1/4
DST
1/4
#3
446
613
970
1145
1544
3190
DST 516
5/16
#3
457
568
1209
1712
2422
TEK 50
#12
#5
487
699
913
1527
3270
3593
DSTR 1.1/2"
#12
#5
3270
3593
DSTR 1"
1/4
#3
1510
DSTR 516
5/16
#3
2200
=Ultimate Pullout Values
Fastener
(avg. lbs. ultimate) - SIDEWINDERS
Steel Gauge (lbs.)
Model
Dia.
Pt.
20
18
16
14
12
3/16
1 114
SWD
1/4
#3
1477
SWDR 1.1/2"
#12
#5
2375
SWDR 1"
1/4
#3
1900
1900
SWDR 516
1 5/16
#3
1 2480
2480
Aluminum Curtain Wall Extrusion
Ultimate Pullout Values A
(average lbs. ultimate)
Fastener
Thickness
Model
Dia.
Pt.
.114
.092
.365
.132
DST 10
114
#3
1265
2750
SWD 10
1A
#3
1120
1420
SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into
contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.
PH-13
Pipe Hangers
����ipe.ha
-Vol
er
"Owl
,�
Su r t'S,
Iro
'T.
t
Powering business worldwide
As a global diversified power management company, we
help customers worldwide manage the power needed
for buildings, aircraft, tri1C1(s, cars, machinery
and businesses.
Eaton's innovative technologies help customers manage
electrical, hydraulic and mechanical power more reliably,
efficiently, safely and sustainably.
F I
-T*N
Powering Business Worldwide
We deliver:
Electrical solutions that use less energy, improve power reliability
and make the places we live and work safer and more comfortable
• Hydraulic and electrical solutions that enable machines
to deliver more productivity without wasting power
Aerospace solutions that make aircraft lighter, safer and less costly
to operate, and help airports operate more efficiently
Vehicle drivetrain and powertrain solutions that deliver
more power to cars, trucks and buses, while reducing fuel consumption
and emissions
We provide integrated
solutions that help make
energy, in all its forms,
more practical and
accessible.
With 2012 sales of
$16-3 billion, Eaton
has approximately
103,000 employees
around the world and
sells products in more
than 175 countries.
Introduction
B-Line is a leading manufacturer and fabricator of metal products used in the support of pipe and equipment
for industrial, residential, commercial, utility, and OEM installations. B-Line is proud of the exacting standards
of research, design, engineering, and manufacturing that go into each and every product that comprise our
pipe hanger product line. Our customers have access to the most complete support systems offered in the
industry, including pipe hangers, metal framing, cable tray, slotted angle, seismic bracing, fasteners, telecom,
enclosures and anchors.
Many of B-Line's products are listed by Underwriters' Laboratories, Inc. and FM Global approved for fire
sprinkler system installations. All B-Line products are manufactured to meet or exceed industry standards set
for their design and manufacture.
B-Line products are produced in five modern plants consisting of over 1,000,000 square feet. These facilities
are located in Highland, Illinois; Troy, Illinois; Reno, Nevada; Corona, California and Sherman, Texas.
Regional sales and distribution centers are located throughout the United States stocking standard B-Line
products for quick service and delivery.
This catalog is designed to be helpful to engineers and contractors in the application and selection of pipe
hangers, supports and seismic bracing for construction and maintenance.
If a unique application requires a special product not included in this catalog, B-Line engineering personnel
are ready to furnish design consultation and realistic material estimates. In addition, sales representatives with
engineering expertise are located throughout the United States and abroad for your convenience.
WARNING
All hanger products in this catalog are intended for installation and service as illustrated or described. Do not
use them for any purposes other than those described in this catalog. Products that are used for unintended
purposes could fail, resulting in severe personal injury or death.
Examples of misapplications which could cause severe personal injury or death include, but are not limited to:
• Using a beam clamp on a beam other than those described in the catalog;
• Using concrete inserts as anchors for pulling pipe up to the required elevation;
• Suspending clevis hangers, one under another, which could result in an accumulative load that is
greater than that which the pipe hanger will support.
B-Line pipe hanger and support products are manufactured in accordance with industry standards. Our
customers should exercise care to use these products properly so as to avoid potential accidents. Contact
B-Line for assistance with proper installation and use of the products in this catalog.
MSS
Manufacturers Standardization Society BSI
of the ISO 9001:2008
Valve and Fitting Industry, Inc.
C u` u5 FM o5F?pd
0
LISTED APPROVED
Eaton's B-Line Business
509 West Monroe Street
Highland, Illinois 62249-0326
Phone:800-851-7415
Fax: 618-654-1917
RI
www.cooperbline.com
B-Line
by FA-N
Pipe Hangers & Supports
Table of Contents
Applications & Pictorial Index .................................... 3-16 _
Strut Systems Information ..........................................
17-18
Technical Data
Materials & Corrosion..........................................................
19
Finishes & General Information ..........................
19-20
Recommended Specifications .............................
21-26
Beam Clamps
C-Clamps................................................................................
28-34
Bottom Beam Clamps .................................................
35-43
TopBeam Clamps..................................................................
44
Trus Joist & Angle Iron Beam Clamps .........
45-46
Pipe Hangers
Clevis Hangers...................................................................
48-58
`J' Hangers.....................................................................................
54
BandHangers.....................................................................
59-62
Split Clamps & Hangers, Rings .................
63-66, 71
Wall Mount Lay -In Hangers ............................................
66
WireHangers.......................................................................
67-69
SpringHangers..........................................................................
70
Pipe Clamps
Risers..........................................................................................
74-75
Underground Clamps ...................................................
76-77
Clamps......................................................................................
78-88
Straps.........................................................................................
89-92
CPVC Hangers.................................................................
93-102
Plastic KWIK-CLIPTM..............................................
103-104
Pipe Rollers & Roller Supports
Roller Hangers.............................................................
106-107
Roller Supports............................................................
108-116
Roller Stands.................................................................
117-119
Spring Cushion Roller Hanger ..................................
120
Rollers..................................................................................
121-122
Pipe Supports, Guides, Shields & Saddles
Calcium Silicate Shields .................................................
124
Stands & Supports ...................................................
125-139
Isolators, Guides & Anchors ............................
140-146
Slides, Shields, Saddles .......................................
147-166
TOLCOTM Seismic Bracing
Sway Bracing Pipe Clamps ..............................
168-172
Sway Bracing Attachments ..............................
173-183
Mechanical Fast Clamps ................................................
184
Pre -Stretched Aircraft Cable ......................................
185
Cable Sway Brace Attachments ..................
186-187
Sway Brace Main Pipe Attachments .......
188-190
Concrete Inserts
Concrete Deck Inserts ..........................................
192-193
Spot Inserts & Insert Nuts .................................
194-199
Continuous Concrete Inserts ..........................
200-202
AnchorClips..............................................................................
203
Brackets
LightDuty......................................................................... 206-208
MediumDuty............................................................................. 209
HeavyDuty.................................................................................. 210
Brackets w/ U-Bolts........................................................... 211
Upper Attachments
Ceiling Flange..........................................................................
214
Angle Supports............................................................
215-218
Swivel Attachment...............................................................
219
Bolted & Welded.........................................................
220-222
Concrete Plates..........................................................
223-225
Rod Beam Attachments ..................................................
226
Threaded Accessories
Eye Sockets & Nuts .................................................
228-229
U-Bolts................................................................................
230-232
Miscellaneous Accessories ..............................
233-235
Rods, Couplings, Washers & Hardware ..........
236-247
Vibra TroITM
Pads.......................................................................................
251-253
MoldedMounts.......................................................................
253
CupMounts................................................................................
254
Spring Mounts..............................................................
255-260
Vibration & Spring Hangers ..............................
261-268
VibraClampTM..................................................................
269-270
Isolation Products................................................................
271
DURA-BLOKTM
Base..................................................................................................
274
Base & Channel...........................................................
275-277
Base & Clamp Riser...........................................................
278
Base & Harness...........................................................
279-280
Base & Rollers..............................................................
281-282
BaseStand..................................................................................
282
Load Distribution Plate ....................................................
283
KwikWireTM
Clamps...........................................................................................
286 r
WireRope....................................................................................
286
KwikPakTM Kits.........................................................................
287
CableCutter..............................................................................
287
KwikWire Hangers...............................................................
288
Accessories
(Loop, Hook, Bracket Termination) ........
289-293
Reference Data
Metric Conversions.............................................................
295
Miscellaneous Charts
Piping, Tubing, Threaded Rod, etc..........
296-306
Trapeze Hanger Chart ...........................................
307-308
MSS & Federal Specifications to
B-Line Cross References ..............................
309-310
B-Line Compliances & Approvals ...............
311-312
Cross References
Cooper B-Line to TOLCO ..............................
313-314
TOLCO to Cooper B-Line.........................................
315
Anvil/Grinnell to Cooper B-Line/TOLCO
........ 316
Erico to Cooper B-Line/TOLCO .............................
317
PHD to Cooper B-Line/TOLCO ...............................
318
Super Strut to Cooper B-Line/TOLCO .............
319
C & P* to Cooper B-Line/TOLCO ...............................
320
Empire to Cooper B-Line/TOLCO ........................
321
Index...........................................................
322-324
* C & P is Carpenter & Paterson
Pipe Hangers & Supports 2
B-Line
by E.Z•N
.wW l
s� Y j1
qm RAW.JWER 4+
:19 WTiT_
Pictorial Index
Beam Clamps
- 7�1
B351L
B3036L B3362 thru B3365
Steel C-Clamp Malleable Iron Retaining Strap B3037 B3031-3/8
With Locknut C-Clamp Page 29 Z-Purlin Beam Clamp Light Duty B3033
Page 28 With Locknut Page 29 Malleable C-Clamp Wide Jaw
Page 28 Page 30 Top Flange
C-Clamp
r Page 30
Nr
SO
B3034 Fig.68S Fig.65 Fig.65XT-3/8 Fig.66
Fig.
Throat) Reversible Reversible Reversible
Top Flange (3Steel C-Clamp Steel C-Clamp Steel C-Clamp
Page 31 (11/4" Thhroro
C-Clamp Fg. With Locknut With Locknut With Locknut
Throat) 3 Fig. 67SS
/4" Throat 3/4" Throat 11/4" Throat
Malleable, Page 33 Page 33 Page 34 (3/4" Throat)
Reversible Beam Fig. 68SS
Clamps (11/4" Throat)
Page 32 AllitReversible
}i Stainless Steel
Ak— C-Clamp
With Locknut
Page 35
B303-B309
Beam Clamp Fig. 69 Fig. 69R
Page 36 Retaining Strap Retrofit
6321 Series
Page 37 Retaining Strap Beam Clamp Page 38
Page 36
B312����
Retaining Strap B3054
Ir Page 39 moo Malleable Iron
B3050 B3040 B3055 Beam Clamp
Beam Clamp Adjustable Beam Clamp Steel Beam Clamp Page 42
Page 40 Page 40 Page 41
e0l
B3291 thru B3298 B3042 B3042T Fig. 130
UFS Forged Steel B3045 Trus Joist
Top Beam Clamp Side Beam Clamp Bar Joist Hanger
Beam Clamp Page 44 Beam Clamp
Page 43 g Page 44 Page 45 Page 46
Pipe Hangers &Supports B-Line
4
by FA-N
Pictorial Index
Pipe Hangers
f
Fig. 1 CBS
Clevis Pipe Spacer B3B3100C
B3100 gWWA 63100E
Page 48 Standard B3108 Plastic Coated
Clevis Hanger Felt Lined
Clevis Hanger Page 51 Extended Standard
Pages 49 & 50 Clevis Hanger Clevis Hanger Standard
Page 52 Page 53 Clevis Hanger
Page 53
f
I
1 I
B3690 B3690F B3106V
B3690C B3109 B3106
Adjustable 'J' Felt Lined Plastic Pipe
1 Plastic Coated Flat Top Clevis Vee Bottom Support Channel
Hanger Adjustable
anger Adjustable 'J' Hanger Hanger Clevis Hanger p Page 56
Page 54 Page 54 Page 54 Page 55 Page 56Poo 0
B3104
B3104F
Light Duty
Felt Lined
Clevis Hanger
Light Duty
Page 57
Clevis Hanger
Page 57
Fig. 2
Adjustable Band Hanger
Page 59
B3104C
Plastic Coated
B3104CT
Light Duty
Copper Tubing
Clevis Hanger
Light Duty Clevis
Page 57
Hanger
Page 58
B3104CTC
Plastic Coated
Copper Tubing
Light Duty Clevis
Hanger
Page 58
010
0
B317OCTC
Copper Tubing
Plastic Coated
Adjustable Swivel Ring
Page 60
♦ DURA-COPPER" Finish
Ik Available in DURA-GREEN'" Finish (Other hangers may be available with the DURA-GREEN finish, contact factory)
B-Line 5 Pipe Hangers & Supports
by E.Z•N
C)
Fig. 2F
Felt Lined
Adjustable Band Hanger
Page 59
B317OCT
Copper Tubing
Adjustable Swivel Ring
Page 60
Pictorial Index
Fig.120RWA Fig.120
Retrofit Wrap Around `U' Hanger
"u Hanger Clamp Page 68
Page 67
BH-2-4
BH-5-8
BH-9-12
Parallel Strap Hanger
Page 71
Pipe Hangers (Continued)
Fig. 200
Trimline Adjustable
Band Hanger
Page 61
Fig. 200F
Felt Lined
Trimline Adjustable
Band Hanger
Page 61
�1
Fig. 200C
Plastic Coated
Trimline Adjustable
Band Hanger
(I ) Page 61
B3175
Ring and Bolt Hanger
Page 65
Fig. 200 H
Heavy Duty
Band Hanger
Page 62
B3198H
Hinged Extension
Split Pipe Clamp
Page 63
B3198HCT
Copper Tubing
Hinged Extension
Split Pipe Clamp
B3175CT
Copper Tubing
Ring and Bolt Hanger
Page 65
Page 64
B3190
Offset 'J' Hook
Page 66
(111 go--- -
Fig. 120MJ Fig. 120W
Mutt & Jeff Wrap Around
`U' Hanger `U' Hanger
Page 69 Page 69
BH-2-4-R
BH-5-8-R
BH-9-12-R
i Right Angle Strap Hanger
Page 71
♦ DURA-COPPER'"" Finish
B3198R
Extension
Split Pipe Clamp
Page 63
B3198RCT
Copper Tubing
Extension
Split Pipe Clamp
Page 64
B3191
Straight 'J' Hook
Page 66
F
B3262
Light Duty
Spring Hanger
Page 70
BL1400 thru
11311-1490
Hanger
Page 71
Pipe Hangers &Supports B-Line
6
by FA-N
Pictorial Index
Pipe Clamps
P :2
B3373
Standard Riser Clamp
Page 74
B3132
Two -Bolt
Underground Clamp
Page 76
B3132W
Lug Washer
Page 76
B3146
Heavy Duty Double
Bolt Pipe Clamp
Page 85
1�_
B3134
Four -Bolt
Underground Clamp
Page 77
lb�
B3134W
Washer
Page 77
B314OF
Felt Lined
Standard Pipe
Clamp
Pages 79-80
f �
r~
u �
i
Fig. 4113
Pipe Clamp For
Sway Bracing
Page 86
B3373C
Plastic Coated
Standard Riser Clamp
Page 74
B3373F
Felt Lined
Standard Riser Clamp
Page 74
Fig. 4A
Pipe Clamp for
Sway Bracing
Page 78
B3141
A.W.W.A. Pipe Clamp
Page 81
B3148
Offset Pipe Clamp
Page 87
B3373CT
Copper Tubing
Riser Clamp
00=0 Page 75
B3373CTC
=90" Copper Tubing
Plastic Coated
Riser Clamp
Page 75
B3140
Standard Pipe Clamp
Pages 79-80
a
B3142
Heavy Duty Pipe Clamp
Page 82
♦ DURA-COPPER'" Finish
B3149
Marine Hanger
Page 88
J
Ad
B3140C
Plastic Coated
Standard Pipe Clamp
Pages 79-80
B3144
Double Bolt Pipe Clamp
Pages 83 & 84
B3180FL
Flush Mount
Pipe Strap
Page 89
B-Line 7 Pipe Hangers & Supports
by E.Z•N
Pictorial Index
Pipe Clamps (Continued)
t
B3180
Extended Leg
Pipe Strap
Page 90
j. 1
Fig. 24
Double Fastener
Side Mounted
CPVC Strap
Page 96
Fig. 29
Double Offset
Hanger & Restrainer
for CPVC Pipe
Page 101
B2400
Standard Pipe Strap
Pages 91-92
Fig. 25
Surge Restrainer
Page 97
B3184
Light Duty
Offset Hanger &
Restrainer for
CPVC & IPS Pipe
Page 102
Fig.22 Fig.22L2 Fig.23
Single Fastener Sin One Hole Hanger/Restraint
g Double Fastener
CPVC Strap For CPVC & Steel Pipe CPVC Strap
Page 93 g Page 95
r Fig. 28 Fig. 28M
`TJ Stand -Off Hanger & Offset Hanger &
Fig. 27 Restrainer for Restrainer for
Speed Nut CPVC Pipe CPVC & IPS Pipe
Page 98 Page 99 Page 100
BPRC Series BPIC Series
Rod Mount BPSC Series
KWIK-CLIP Channel Mount
Page 103 KWIK-CLIP
Page104
Pipe Rollers & Roller Supports
� 1
Ve
B3110 B3114
Adjustable Steel Pipe Roll With Sockets B3122 B3122A
Yoke Pipe Roll Page 107 Adjustable Roller Support Adjustable Double
Page 106 , Page 108 Roller Guide
Page 109
1k Available in DURA-GREEN'" Finish
Pipe Hangers &Supports $
B-Line
by EA-N
Pictorial Index
Pipe Rollers & Roller Supports (Continued)
B3120 �+!� l
Roller Chair '?B3124 1.._ '._ B3126
Page 110 Roller Support g >f' Roller Support
a - Page111 Page112
B218 B219 B479 B3117SL
Pipe Rollers Pipe Rollers B379 Pipe Rollers Steel Roller Stand
Page 113 Page 114 Pipe Rollers Page 115 Page 116 Page 117
.z 0
B3118SL 63119SL
Adjustable Roller Stand Roller With Steel B3264 B3114R B3117R
With Base Plate Base Plate Spring Cushion Hanger Long Pipe Roll Only Short Pipe Roll Only
Page118 Page119 Page120 Page121 Page122
Pipe Supports, Guides, Shields & Saddles
B3088T
Base Stand B3380 se Stand B3089
Threaded Base Stand '
thru B3384 B3088ST
360' Calcium B3088S Seismic Threaded Pipe Support Pipe Saddle
Silicate Shield Seismic Base Stand Base Stand B3096 Adjuster Support
Page 124 Pages 125 & 126 Pages 125 & 126 Adjustable Pipe Page 128 With U-Bolt
Saddle Support Pages 129 & 130
Page127
1
B3092 B3093 B3097 B3098 B3094
B3095 Adjustable Pipe Saddle Adjustable Pipe Pipe Saddle Adjustable Pipe Flange Support
Pipe Saddle Support Support With Yoke Saddle Support With Strap Support w/U-Bolt Page 139
Pages 131 & 132 Pages 133 & 134 Pages 135 & 136 Page 137 Page 138
B-Line 9 Pipe Hangers & Supports
by E.Z•N
Pictorial Index
Pipe Supports, Guides, Shields & Saddles (Continued)
B3195 B3281 thru
I.P.S. Isolator B3287
B3195CT r Pipe Alignment B3147A
Copper Tubing Guide B3147B
Isolator Pages Anchor Chairs
Page 140 " 141 & 142 Pages 143 & 144
B2417
Pipe Guides
-*A_ Page 143
�-
B3256 Aik
Hold -Down B3257
Anchor Clamp Base Plate B3891 thru B3897 Pipe Slides
Page 145 Page 146 Pipe Slides Pages 151 - 154
Pages 147 - 150
B3155
B3151 B3153 B3154 Short Insulation BPH Series
Insulation Insulation Protection Short Insulation Protection Shield Snap N'Shield
Protection Shield Shield With Tabs Protection Shield With Tabs Clevis
Page162 Page162 Page163 Page163 Page164
B3991 thru B3993
TOLCOT" Seismic Bracing
AUL
Fig. 4B
Pipe Clamp For Fig. 4L
Fig.4A Sway Bracing Longitudinal "In- Fig. 4LA
Page 169 Line" Sway Brace
Pipe Clamp For g Attachment Longitudinal "In -
Sway Bracing Page 170 Line" Sway Brace
Page 168 Attachment
r Pages 171 & 172
,=W
Fig. 825A
Bar Joist Sway
Brace Attachment
Page175
Fig. 828
Universal Sway
Brace Attachment
Page 176
Fig. 906
Sway Brace Multi -
Fastener Adaptor
Page177
Fig. 800
Adjustable Sway
Brace Attachment
To Steel
Page 173
Fig. 907
4-Way
Longitudinal Sway
Brace Attachment
Page 178
B3160 thru B3165
Pipe Covering
Protection Saddle
Pages 155 - 160
0
BPS Series
Snap N'Shield
Pages 165 & 166
Fig. 825
Bar Joist Sway
Brace Attachment
Page174
Fig. 909
No -Thread Swivel
Sway Brace
Attachment
Page 179
Pipe Hangers &Supports B-Line
10
by EA-N
Pictorial Index
TOLCOT"' Seismic Bracing (Continued)
Fig. 910-''' i
Swivel Sway Brace
Attachment
t ct Fig. 980 Fig. 981 p
Page
180 .%
Universal Swivel Fast -Attach
Fig.975 Sway Brace Universal Swivel Sway Fig. 985 Fig. 986
Attachment Brace Attachment Mechanical Fast Mechanical Fast
Straight Sway Page 183
Brace Fitting Page 182 g Clamp Clamp
Page181 Page184 Page184
Fig. BRC CABLE
Pre -Stretched ! f
Aircraft Cable_ E
Page 185 "
Fig. 990 Fig. 991 Fig. 1000 Fig. 1001 Fig. 2002
Cable Sway Fast Attach Fast Clamp Sway Brace Sway Brace
Brace Attachment Cable Sway Brace Sway Brace Attachment Attachment
Page 186 Attachment Attachment Page 189 Page 190
Page187 Page188
Concrete Inserts
Fig. 109AF
Spot Insert
Page 194 &
B3019 194a _
Fig. 109A Adjustable Metal -
Concrete Deck Insert Deck Ceiling Bolt
Page 192 & 192a Page 193 B2499
Heavy Duty Spot Insert
Page195
N2500 B3014 B3014N B2505thru
B2500 Steel Insert Nut Malleable Iron Malleable Iron Insert Nut B2508
Light Duty Spot Insert Page 196 Spot Insert Page 197 Spot Insert
Page196 Page197 Page198
BLine 11 Pipe Hangers & Supports
by EA-N
Pictorial Index
Concrete Inserts (Continued)
h
BE-5-8
B2503 B221, B321, B521 BD40 BE-9-12
Heavy Duty Spot Insert Continuous Concrete Inserts Fastener Clip Fastener Clip
Page 199 Pages 200 - 202 Page 203 Page 203
BRACKETS
l' A
B3068
Light Duty Welded B3064 B3066 B3067
Bracket Adjustable Strut Bracket B3065 Medium Duty Welded
Light Duty Welded Bracket Heavy Duty Welded Bracket
Page 206 Page 207 Bracket Page 209 Page 210
Page 208
1� r B3069E
B3069W " O" Bracket
Welded Knee Brace Page 211
Page 211
Upper Attachments
^� B3060L
Side Beam
�. Angle Clip
Page 215
B3199
Ceiling Flange
Page 214
B3070
Reversible Angle Clip
Page 215
B3199CT
Dura-Copper Coated
Ceiling Flange
Page 214
B3060
Side Beam Angle Clip
Page 216
Fig. 78
All Steel Ceiling Plate
Page 214
Fig. 50 B3061
Fig. 51 Angle Bracket
Side Beam Angle Clip Side Beam Bracket For Page 217
Page 216 NFPA Rod & Fastener Sizing
Page 217
♦ DURA-COPPER"" Finish
Pipe Hangers &Supports B-Line
12
by EJ-N
Pictorial Index
Upper Attachments (Continued)
Fig.58 j Fig.75
Threaded Side ` Swivel Attachment
Beam Bracket f Page 219
Page 218 f
Fig. 56
Tapped Side
Beam Connector
Page 217 IL
B3062 B3083 B3080S (Short)
B3058 B3083WO B3080L (Long)
Side Beam Connector Side Beam Bracket Structural Welding Lu
Page 220 Welded Beam Attachment 9 g
Page 220 Page 221 Page 222
44,10110
B3085 B3086 B3084 B3082
Rod Attachment Concrete Plate Clevis Concrete Plate Single Lug Concrete Plate Rod Beam Attachment
Page 223 Page 224 Page 225 Page 226
Threaded Accessories
B3188C
t'; 4 Plastic Coated
`A-� Standard U-Bolt
Pages 231 & 232
B501 B3188
Light Weight U-Bolt Standard U-Bolt
B3200 Page 230 Pages 231 & 232
Weldless Eye Nut
Page 229
1 1
B3224
B3203 Hanger Adjuster
B3222 Eye Socket B3201 Extension Piece B3223 B3224CT B3202
er
Page 228 Forged Steel Clevis Page 234 Page 234 Offset Eye Socket Dura-Co pp Coated Turnbuckle
Page 233 g Hanger Adjuster Page 235
♦ DURA-COPPER" Finish Page 235
B-Line 13 Pipe Hangers & Supports
by EA-N
Pictorial Index
Threaded Accessories (Continued)
OOA�
B3210
B3205 Eye Rod B3210X
Machine Threaded Rod ATR Page 239 Linked Eye Rod
Page 236 All Threaded Rod Page 240
Page 236 � j
B3214
Tie Bolt
Page 238
B3211
1�I Welded Eye Rod
239
B3211X
Fig. 98 Linked Welded Eye Rod
Rod Stiffener Fig. 98B Page 240
Page 237 Rod Stiffener with x
Break Off Bolt Head
Page 237 SC228 B3213
Coach Screw Rod
Rod Stiffener 000Page 238
�- Page 237
i
B655
B3212 "�',' - Steel Rod Coupling
J-Bolt - Page 242
Page 241 B656
B3228 DS 16 x 2 Steel Reducer
Hex Head Lag Bolt #16 x 2" Rod Coupling ` -Page 242
_ Page 241 Drive Screw
Page 241
F- r -'
B3220 B200
Malleable Iron Square Washer B3248
Rod Coupling Page 243 Steel Washer Plate HN - Hex Nut
Page 243 Page 244 B3234 HHN - Heavy Hex Nut
Bevel Washer Page 245
Page 244
AWA
FW LW FFW ATB Wedge Anchor
Flat Washer Lock Washer Flat Fender Washer Toggle Bolt Page 247
Page 246 Page 246 Page 246 Page 247
Pipe Hangers &Supports B-Line
14
by FA-N
Pictorial Index
VIBRA TROLTM
NNP
Ribbed Neoprene Pad
Page 251
A
NVD
Double Deflection
Page 253
CNP
Cork and Ribbed
Neoprene Pad
Page 251
CM
Metal Housing and Neoprene
Page 254
HMLT/HMT
Housed 1 "
Deflection Mounting
Pages 259 & 260
SHE
Isolation Spring Hanger
Pages 267 & 268
F �
r
CNNK
Cork, Ribbed Neoprene
and Steel
Page 252
OML/OM
Spring Mount
Pages 255 & 256
RH
Neoprene Hanger
Page 266
BVT
VibraClamp
Tubing Sizes
Page 269
BVP
VibraClamp
Pipe Sizes
Page 270
VRP
Rubber Cube Pad
Page 252
BVS
Vibra StripTM for
15/8" Wide B-Line
channel
Page 253
HSL/HS
Vibration Spring Hanger
Pages 261 & 262
B1999
Vibra Cushion
Page 271
rat:1�
J
rL
HMLE/HME
Housed 1 "
Deflection Mounting
Pages 257 & 258
H ESL/H ES
Combination Spring
& Neoprene
Pages 263 & 264
ISO
ISO Pipe
Page 271
DU RA-BLOKTM
DBP & DBM DB Series AO
Bases Base & Short Channel D136 Series D1310 Series
Page 274 Page 275 Base & Tall Channel Double Base & Long Channel
Page 276 Page 277
B-Line 15 Pipe Hangers & Supports
by E.Z•N
Pictorial Index
DURA-BLOK"' (Continued)
DBM Series
Base & Clamp Riser
Page 278
CLDP10
Load Distribution Plate
Page 283
KwikWire"'
KwikWire Clamp
Page 286
Wire Rope Cutter
Page 287
KwikWire Accessories
BKL & BKLK
Loop Termination
Page 290
DBR Series
Base & Fixed Height
Roller Assembly
AO Page 281
60
DB_DS Series
I Bases &Harness Assembly
000 4 Pages 279 & 280
DBR Series DBE Series
Base & Adjustable Height Base & Adjustable
Roller Assembly Height Channel
Page 282 Page 282
Wire Rope
Page 286
KwikPak'" Kit
Page 287
KwikWire Accessories
BKH & BKHK
Single Hook Termination
Page 291
KwikWire Accessories
BKYH & BKYHK
Double Hook Termination
Page 292
KwikWire Hanger
Page 288
POO - - =a :-
KwikWire Accessories
BKA & BKAK
Angle Bracket
Termination
Page 293
Pipe Hangers &Supports B-Line
16
by E.Z•N
Strut Systems
B-Line's metal framing support system is designed with many time-
saving features. Fully adjustable and reusable, with a complete line of
channels, fittings, and accessories for multi -purpose applications.
i
SELECTION CHART
for Channels, Materials and Hole Patterns
Channel
Type
Height
LLJ
Channel
Dimensions
Width
I__I
Material
Steel
1
& Thickness*
Stainless
Steel
Alum. Type Type
304 316
2 3 4
SH
Channel
S
��
Hole Pattern **
H17/8 TH K06�
•• �/�
Number
Available Finishes: Electro-Galvanized
Part Thread
Number Size E41�31
NW524 1/4"-20
NW528 3/8"-16
NW525 1/2"-13
Available Finishes: Electro-Galvanized
B2000 Series
i
B2001
Pipe Size
3/8" (10)
Ga.
16
B2008
1/2"
(15)
16
B2009
3/4"
(20)
14
B2010
11.
(25)
14
B2011
11/4"
(32)
14
B2012
11/2"
(40)
12
B2013
2"
(50)
12
B2014
21/2"
(60)
12
B2015
3"
(80)
12
B2016
31/2"
(90)
11
B2017
4"
(100)
11
B2018
41/2"
(115)
11
B2019
5"
(125)
11
B2020
6"
(150)
11
B2021
7"
(175)
11
B2022
8"
(200)
11
Available Finishes: Electro-Galvanized, Aluminum, Stainless,
DURA-COPPER Painted, Hot -Dip Galvanized and PVC coated.
Nut and bolts are included with all two-piece clamps.
** Add "PA" to Part No. for Pre -assembled
B-Line
by F:'I•N
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
17
Pipe Hangers & Supports
Strut Systems
Below are some basic clamp and cushions to be used with a strut system. For the industry's most complete
line of strut and strut fittings, refer to B-Line's Strut Systems Engineering Catalog.
B2000 Series
T
�
B2023
•
1/4"
•• • .
(6.3)
16
B2024
3/8"
(9.5)
16
B2025
1/2"
(12.7)
16
B2026
5/8"
(15.9)
16
B2027
3/4"
(19.0)
16
B2028
7/8"
(22.2)
16
B2029
1 "
(25.4)
14
B2030
11/8"
(28.6)
14
B2031
11/4"
(31.7)
14
B2032
13/8"
(34.9)
14
B2004
11/2"
(38.1)
14
B2011
15/8"
(41.3)
14
B2005
13/4"
(44.4)
12
B2036
17/8"
(47.6)
12
B2037
2"
(50.8)
12
B2038
21/8"
(54.0)
12
B2039
21/4"
(57.1)
12
B2013
23/8"
(60.3)
12
B2041
21/2"
(63.5)
12
B2042
25/8"
(66.7)
12
B2043
23/4"
(69.8)
12
B2014
27/8"
(73.0)
B2045
3"
(76.2)
fl
B2046
31/8"
(79.4)
B2047
31/4"
(82.5)
12
B2048
33/8"
(85.7)
12
B2015
31/2"
(88.9)
12
B2050
35/8"
(92.1)
11
B2051
33/4"
(95.2)
11
B2016
4"
(101.6)
11
B2054
41/8"
(104.8)
11
B2055
41/4"
(107.9)
11
B2056
43/8"
(111.1)
11
B2017
41/2"
(114.3)
11
B2058
45/8"
(117.5)
11
B2059
43/4"
(120.6)
11
B2060
47/8"
(123.8)
11
B2061
5"
(127.0)
11
B2062
51/8"
(130.2)
11
B2063
51/4"
(133.3)
11
B2064
53/8"
(136.5)
11
B2065
51/2"
(139.7)
11
BVT & BVP
Series
Vibra-Clamp'"
CopperFor
OD Sizes
Catalog
BVT025
Copper
•. Tubing Size
1/4" (6.3)
Copper
-- --
BVT037
3/8"
(9.5)
1/4"
(6)
BVT050
1/2"
(12.7)
3/8"
(10)
BVT062
5/8"
(15.9)
1/2"
(15)
BVT075
3/4"
(19.0)
5/8"
(17)
BVT087
7/8"
(22.2)
3/4"
(20)
BVT100
1 "
(25.4)
--
--
BVT112
11/8"
(28.6)
1 "
(25)
BVT125
11/4"
(31.7)
--
--
BVT137
13/8"
(34.9)
11/4"
(32)
BVT150
11/2"
(38.1)
--
--
BVT162
15/8"
(41.3)
1112"
(40)
BVT175
13/4"
(44.4)
--
--
BVT187
17/8"
(47.6)
--
--
BVT200
2"
(50.8)
--
--
BVT212
21/8"
(54.0)
2"
(50)
BVT225
21/4"
(57.1)
--
--
BVT250
21/2"
(63.5)
--
--
BVT262
25/8"
(66.7)
21/2"
(65)
BVT300
3"
(76.2)
--
--
BVT312
31/8"
(79.4)
3"
(80)
BVT362
35/8"
(92.1)
31/2"
(90)
BVT400
4"
(101.6)
--
--
BVT412
41/8"
(104.8)
4"
(100)
BVT612
61/8"
(155.6)
6"
(150)
Available for tubing and pipe sizes
1/4" to 6", OD sizes 1/4" to 65/811.
Easy one tool installation, dampens
vibration and noise, secures tubing
firmly, and protects against galvanic
reaction.
Stainless Steel available
B1999
Vibra-CushionT"
• Inhibits Galvanic Reaction 0
• Reduces Sound & Vibration
• Used on refrigeration, HVAC, copper
tubing, glass pipes & hydraulic lines o
Available in 20 Ft. rolls. in
For .
Nominal
Size
3/8" (10)
• Conduit or
Length of
Vibra-Cushion
21/8" (54.0)
•
Use
Clamp No.
B2002
1/2"
(15)
25/8"
(66.7)
B2009
3/4"
(20)
31/4"
(82.5)
B2031
111
(25)
41/8"
(104.8)
B2004
11/4"
(32)
53/16"
(131.8)
B2012
11/2"
40
515/16"
150.8
B2038
2"
50
71/2"
190.5
B2042
21/2"
65
9"
228.E
B2046
3"
(80)
1111
(279.4)
132051
31/2"
90
121/2"
317.5
B2055
4"
(100)
141/2"
(368.3)
B2059
5"
(125)
177/16"
(442.9)
B2067
6"
(150)
203/4"
(527.0)
I B2116
For
Thinwall
(EMT) Conduit
Nominal
Size
3/8"
(10)
Length
Vibra-Cushion
113/16"
of
(46.0)
Use
Clamp No.
B2027
1/2"
(15)
23/16"
(58.7)
B2002
3/4"
(20)
27/8"
(73.0)
B2003
1 "
(25)
35/8"
(92.1)
B2032
11/4"
(32)
43/8"
(120.6)
B2036
11/2"
(40)
57/16"
(138.1)
B2012
2"
(50)
1 67/8"
1 (174.6)1
B2013
CopperFor
Nominal
Size
1/4" (6)
Length of
Vibra-Cushion
13/16" (30.2)
Use
Clamp No.
B2026
3/8"
(10)
19/16"
(39.7)
B2027
1/2"
(15)
17/8"
(47.6)
B2028
5/8"
(17)
25/16"
(58.7)
B2029
3/4"
(20)
23/4"
(69.8)
B2030
1 "
(25)
31/2"
(88.9)
B2032
11/4"
(32)
45/16"
(109.5)
B2011
11/2"
(40)
51/8"
(130.2)
B2036
2"
(50)
611/16"
(169.9)
B2013
21/2"
(65)
81/4"
(209.5)
B2014
3"
(80)
913/16"
(249.2)
B2048
31/2"
(90)
113/8"
(288.9)
B2052
4"
(100)
1215/16"
(328.6)
B2056
5"
(125)
61/8"
(409.6)
B2064
6"
(150)
191/4"
(488.9)
B2112
8"
poo)
251/2"
(647.7)
B2128
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Pipe Hangers & Supports
18
B-Line
by FA-N
Technical Data
MATERIALS
Carbon Steel
Carbon steel is used in the
manufacture of B-Line pipe hangers
and supports. Excellent strength
characteristics and adaptability to
cold forming provide a well
engineered design. By cold forming
the steel, mechanical properties are
increased, adding to the structural
integrity of the fabricated hanger.
Stainless Steel
AISI Type 304 and Type 316 are
non-magnetic members of the
austenitic stainless steel group.
Several conditions make the use of
stainless steel ideal. These include
reducing long term maintenance
costs, high ambient temperatures,
appearance, and stable structural
properties such as yield strength,
and high creep resistance.
CORROSION
All metal surfaces exposed to the
environment are affected by
corrosion. Depending on the physical
properties of the metal and its
proximity to other dissimilar metals,
an electrochemical reaction may
occur which causes an attack on the
metal itself, resulting in corrosion.
Chemical corrosion is limited to
highly corrosive environments, high
temperatures, or a combination of
both.
FINISHES
Zinc Coatings
Protective zinc coatings are available
on a number of pipe hangers and
accessories in three basic forms:
Electro-galvanized, pre -galvanized, and
hot -dip galvanized after fabrication. In
all cases, the zinc protects the steel
first as a sacrificial anode to repair bare
areas on cut edges and gouges.
When exposed to air and moisture,
zinc forms a tough, adherent protective
film consisting of a mixture of zinc
oxides, hydroxides, and carbonates.
The corrosion resistance of zinc is
directly related to its thickness and the
environment. For example a 0.2 mil
(5 µm) coating will last twice as long as
a 0.1 mil (2.5 µm) coating in the same
environment.
Electro-Galvanized
(ASTM B633 SC1 or SC3)
An electro-galvanized process deposits
a coating of zinc on the steel by
electrolysis from a bath of zinc salts.
This coating is pure zinc and adheres
to the steel with a molecular bond. A
maximum of 0.5 mils (12.7 µm) of zinc
can be applied by this method. This
coating is recommended for in -door
use in relatively dry areas.
Pre -Galvanized Zinc
(ASTM A653 Coating
Designation G90)
Pre -galvanized zinc is produced by
continuously rolling the steel coils or
sheets through molten zinc at the steel
mills. This is also known as "mill -
galvanized" or "hot -dipped mill galva-
nized". Coils are then slit to size for
fabrication of pipe hangers. Coating
thicknesses of G90, is 0.90 ounces per
square foot (0.27 kg/m2) of steel
surface.
Zn
ZnFe l
Fe
fZno
Protection of cut edges with zinc coatings.
Cut edges and welded areas are
not zinc coated; however, zinc near the
uncoated metal becomes a
sacrificial anode which protects the
bare areas after a short period of time.
Pre -galvanized steel is not
generally recommended for use
outdoors in industrial environments,
but is suitable for extended exposure in
dry or mildly corrosive atmospheres.
Hot -Dip Galvanized After
Fabrication (ASTM A123)
After a pipe hanger or fitting has been
fabricated, it is completely immersed in
a bath of molten zinc. A metallurgical
bond is formed, resulting in a zinc
coating that completely coats all
surfaces, including edges. Zinc
coatings of this specification have a
minimum thickness of 1.50 ounces per
square foot (0.45 kg/m2) on each side
or a total of 3.0 ounces per square foot
(0.9 kg/m2) of steel.
Hot -dip galvanized after fabrication is
recommended for outdoor exposure.
For best results, a zinc rich paint
(available from B-Line) should be
applied to field cuts. The zinc rich paint
will provide immediate protection for
field cuts and eliminate the short time
period for galvanic action to "heal" the
damaged coating.
Plastic Coating
Some products offered by B-Line are
plastic or vinyl coated for prevention of
galvanic reaction between materials or
for noise reduction. These coated
products can also be used where
contact between glass pipe and hanger
is not desirable. Felt lined hangers may
be substituted for same purpose.
Red Primer
A corrosion resistant metal primer
containing rust inhibitive pigments.
B-Line 19 Pipe Hangers & Supports
by E.Z•N
Technical Data
DURA-COPPERTm and
DURA-GREENTM Epoxy Coatings
DURA-COPPER and DURA-GREEN
are water borne epoxy coatings
applied to B-Line products by a
precisely controlled cathodic electro-
deposition process. This process is
accomplished using a conveyor to
transport parts through several
cleaning, phosphatizing and application
stages prior to being baked (See
diagram below).
This custom designed paint system is
used for painting all copper painted
hanger parts and all green channel,
slotted angle and fittings.
Samples are selected on a routine
basis for Salt Spray (fog) testing to
verify the quality of the finish. These
tests are performed in accordance with
ASTM 13117-73 and evaluated and
rated according to ASTM D1654-79
(Tables 1 & 2). The DURA-COPPER
and DURA-GREEN Epoxy coatings
have been tested and listed by
Underwriters Laboratories in
accordance with "Standard for Pipe
Hanger Equipment for Fire Protection
Service, UL 203" and meet or exceed
all requirements of Federal
Specification TT-C-49013 Paragraph 3.
DURA-COPPERTM & DURA-GREENTM EPDXY COATING PROCESS
Quality Assurance
B-Line's Quality Assurance Program
has been developed and implemented
for compliance to various industry
standards and specifications.
TANK 1
TANK 2
TANK 3
TANK 4
TANK 5
TANK 6
TANK 7
TANK 8
BAKE OVEN
Parts are
Rinse is
Phosphatized
The material
Deionized rinse
The electro-
The first
The final rinse
The curing
thoroughly
applied to
sealer is applied
moves through
prepares the
coating tank
post rinse
insures a
process takes
cleaned and
remove
to insure
clear water
metal for the
applies a
removes any
smooth,
20 minutes at a
phosphatized.
insoluble salts
corrosion resis-
rinse to remove
cathodic
uniform coat of
unelectrically
nonblemish
baking
and unreacted
tance and paint
excess phos-
electro-coating.
epoxy paint to
attracted
finish.
temperature of
phosphates.
adhesion.
phates.
the entire
solids.
375°F (199°C).
surface.
LJLJL�jL.LjLik
SALT SPRAY TEST RESULTS DURA-COPPER
DURA-COPPER out performs
Epoxy Copper Plating
4 to 1
Copper Plating
Elapsed Time
(1) All salt spray (fog) tests conducted in accordance with ASTM 13117-73 and evaluated and rated
according to ASTM D1654-79 Tables 1 & 2. Tests were performed and certified by an independent testing laboratory.
General Information
Torque
The torque values in this catalog are to be used as a guide only. The relationship between the applied torque or
torque wrench reading and the actual tension created in the bolt may be substantially different. Important factors
affecting torque -tension relationships include friction under the bolt head or nut, hole tolerances, and torque
wrench tolerances. Accuracy of many commercial torque wrenches may vary as much as plus or minus 25%.
Charts and Tables
Charts and tables in this section are compiled from information published by nationally recognized organizations
and are intended for use as a guide only. B-Line recommends that users of this information determine the validity
of such information as applied to their own applications.
Eaton's B-Line reserves the right to make specification changes without notice.
Pipe Hangers & Supports
20
B-Line
by EA-N
Technical Data
SECTION 15140 - PIPE HANGERS AND SUPPORTS
Part I - GENERAL
1.01 SECTION INCLUDES
A. The work covered under this section consists of the furnishing of all necessary labor,
supervision, materials, equipment, and services to completely execute the pipe hanger and
supports as described in this specification.
1.02 REFERENCES
A. ASTM B633 - Specification for Electrodeposited Coatings of Zinc on Iron and Steel.
B. ASTM A123 - Specification for Zinc (Hot -Dip Galvanized) Coatings on Iron and Steel Products.
C. ASTM A653 - Specification for Steel Sheet, Zinc -Coated (Galvanized) or Zinc -Iron
Alloy -Coated (Galvannealed) by the Hot -Dip Process.
D. ASTM A1011 - Specification for Steel, Sheet and Strip, Hot -Rolled, Carbon, Structural,
High -Strength Low -Alloy, and High -Strength Low -Alloy with Improved Formability.
E. ANSI/MSS SP-58 - Manufacturers Standardization Society: Pipe Hangers and Supports -
Materials, Design, and Manufacture.
F. ANSI/MSS SP-69 - Manufacturers Standardization Society: Pipe Hangers and Supports -
Selection and Application.
G. NFPA 13 - Installation of Sprinkler Systems.
1.03 QUALITY ASSURANCE
A. Hangers and supports used in fire protection piping systems shall be listed and labeled by
Underwriters Laboratories.
B. Steel pipe hangers and supports shall have the manufacturers name, part number, and
applicable size stamped in the part itself for identification.
C. Hangers and supports shall be designed and manufactured in conformance with
ANSI/MSS SP-58.
D. Supports for sprinkler piping shall be in conformance with NFPA 13.
1.04 SUBMITTALS
A. Submit product data on all hanger and support devices, including shields and attachment
methods. Product data to include, but not limited to materials, finishes, approvals, load
ratings, and dimensional information.
Part II - PRODUCTS
2.01 ACCEPTABLE MANUFACTURERS
A. Manufacturer: Subject to compliance with these specifications, pipe hanger and support
systems shall be as manufactured by B-Line, Inc.
2.02 PIPE HANGERS AND SUPPORTS
A. Hangers
1. Uninsulated pipes 2 inch and smaller:
a. Adjustable steel swivel ring (band type) hanger, B-Line Fig. 200.
b. Adjustable steel swivel J-hanger, B-Line 63690.
c. Malleable iron ring hanger, B-Line B3198R or hinged ring hanger,
B3198H.
d. Adjustable steel clevis hanger, B-Line B3104 or B3100.
B Llne 21 Pipe Hangers & Supports
by F.T-N
Technical Data
2. Uninsulated pipes 21/2 inch and larger:
a. Adjustable steel clevis hanger, B-Line B3100.
b. Pipe roll with sockets, B-Line B3114.
c. Adjustable steel yoke pipe roll, B-Line B3110.
3. Insulated pipe - Hot or steam piping:
a. 2 inch and smaller pipes: use adjustable steel clevis with galvanized sheet metal
shield, B-Line B3100 with B3151 or B3153 series.
b. 21/2 inch and larger pipes:
i. Adjustable steel yoke pipe roll with pipe covering protection saddle,
B-Line B3110 with B3160 - B3165 series.
ii. Pipe roll with sockets with pipe covering protection saddle, B-Line
B3114 with B3160 - B3165 series.
4. Insulated pipe - Cold or chilled water piping:
a. 5 inch and smaller pipes: use adjustable steel clevis with galvanized sheet metal
shield, B-Line B3100 with B3151 or B3153 series.
b. 6 inch and larger pipes:
i. Adjustable steel yoke pipe, B-Line B3110, with B3380CW - B3384CW
calcium silicate shield.
ii. Pipe roll with sockets, B-Line B3114, with B3380CW - B3384CW calcium
silicate shield.
B. PIPE CLAMPS
1. When flexibility in the hanger assembly is required due to horizontal movement, use
pipe clamps with weldless eye nuts, B-Line B3140 or B3142 with B3200. For insulated
lines use double bolted pipe clamps, B-Line B3144 or B3146 with B3200.
C. MULTIPLE OR TRAPEZE HANGERS
1. Trapeze hangers shall be constructed from 12 gauge roll formed ASTM A1011 SS Gr. 33
structural steel channel, 15/8" x 15/8" minimum, B-Line B22 strut or stronger as
required.
2. Mount pipes to trapeze with two piece pipe straps sized for outside diameter of pipe,
B-Line B2000 series.
3. For pipes subjected to axial movement:
a. Strut mounted roller support, B-Line B3126. Use pipe protection shield or
saddles on insulated lines.
b. Strut mounted pipe guide, B-Line B2417.
D. WALL SUPPORTS
1. Pipes 4 inch and smaller:
a. Carbon steel hook, B-Line B3191.
b. Carbon steel J-hanger, B-Line B3690.
2. Pipes larger than 4 inch:
a. Welded strut bracket and pipe straps, B-Line B3064 and B2000 series.
b. Welded steel brackets, B-Line B3066 or B3067, with roller chair or adjustable
steel yoke pipe roll. B-Line B3120 or B3110. Use pipe protection shield or
saddles on insulated lines.
Pipe Hangers & Supports
22
B-Line
by EA-N
Technical Data
E. FLOOR SUPPORTS
1. Hot piping under 6 inch and all cold piping:
a. Carbon steel adjustable pipe saddle and nipple attached to steel base stand sized
for pipe elevation, B-Line B3093 and B3088T or B3090 and B3088. Pipe saddle
shall be screwed or welded to appropriate base stand.
2. Hot piping 6 inch and larger:
a. (Adjustable) Roller stand with base plate, B-Line B3117SL (or B3118SL).
b. Adjustable roller support and steel support sized for elevation, B-Line B3124
F. VERTICAL SUPPORTS
1. Steel riser clamp sized to fit outside diameter of pipe, B-Line B3373.
G. COPPER TUBING SUPPORTS
0
1. Hangers shall be sized to fit copper tubing outside diameters.
0
v a. Adjustable steel swivel ring (band type) hanger, B-Line B3170CT.
d b. Malleable iron ring hanger, B-Line B3198CT or hinged ring hanger B3198HCT.
c. Adjustable steel clevis hanger, B-Line B3104CT.
H. PLASTIC PIPE SUPPORTS
1. V-bottom clevis hanger with galvanized 18 gauge continuous support channel,
B-Line B3106 and B3106V, to form a continuous support system for plastic pipe or flexible
tubing.
I. SUPPLEMENTARY STRUCTURAL SUPPORTS
1. Design and fabricate supports using structural quality steel bolted framing materials
as manufactured by B-Line. Channels shall be roll formed, 12 gauge ASTM
A1011 SS Grade 33 steel, 15/8" x 15/8" or greater as required by loading conditions.
Submit designs for pipe tunnels, pipe galleries, etc., to engineer for approval. Use
clamps and fittings designed for use with the strut system.
2.04 UPPER ATTACHMENTS
A. BEAM CLAMPS
1. Beam clamps shall be used where piping is to be suspended from building steel.
Clamp type shall be selected on the basis of load to be supported, and load configuration.
2. C-Clamps shall have locknuts and cup point set screws, B-Line B351 L, B3036L or Fig.
65XT Top flange C-clamps shall be used when attaching a hanger rod to the top flange of
structural shapes, B-Line B3034 or B3033. Refer to manufacturers' recommendation
for setscrew torque. Retaining straps shall be used to maintain the clamp's position
on the beam where required (Fig. 69, Fig. 69R).
3. Center loaded beam clamps shall be used where specified. Steel clamps shall be
B-Line B3050 or B3055. Malleable iron or forged steel beam clamps with cross bolt shall
be B-Line B3054 or B3291 - B3297 series as required to fit beams.
B. CONCRETE INSERTS
1. Cast in place spot concrete inserts shall be used where applicable, either steel or
malleable iron body, B-Line B2500 or B3014. Spot inserts shall allow for lateral
adjustment and have means for attachment to forms. Select insert nuts to suit
threaded hanger rod sizes, B-Line N2500 or B3014N series.
B-Line 23 Pipe Hangers & Supports
by E.Z•N
Technical Data
2. Continuous concrete inserts shall be used where applicable. Channels shall be 12
gauge, ASTM A 1011 SS Grade 33 structural quality carbon steel, complete with
styrofoam inserts and end caps with nail holes for attachment to forms. The
continuous concrete insert shall have a load rating of 2,000 Ibs/ft. in concrete,
B-Line B221, B321, or B521 (B521 is limited to 1,500 Ibs/ft.). Select channel nuts
suitable for strut and rod sizes.
2.05 VIBRATION ISOLATION AND SUPPORTS
A. For refrigeration, air conditioning, hydraulic, pneumatic, and other vibrating system
applications, use a clamp that has a vibration dampening insert and a nylon inserted
locknut. For copper and steel tubing use B-Line BVT series VibraClamps, for pipe
sizes use BVP series.
B. For larger tubing or piping subjected to vibration, use neoprene or spring hangers B
as required.
0
m
C. For base mounted equipment use vibration pads, molded neoprene mounts, or spring t
mounts as required.
D. Vibration isolation products as manufactured by B-Line, VibraTrol systems.
2.06 ACCESSORIES
A. Hanger rods shall be threaded both ends, B-Line B3205, or continuous threaded rods
of circular cross section. Use adjusting locknuts at upper attachments and hangers.
No wire, chain, or perforated straps are allowed.
B. Shields shall be 180' galvanized sheet metal, 12 inch minimum length, 18 gauge minimum
thickness, designed to match outside diameter of the insulated pipe, B-Line B3151.
C. Pipe protection saddles shall be formed from carbon steel, 1/8 inch minimum thickness,
sized for insulation thickness. Saddles for pipe sizes greater than 12 inch shall have a
center support rib.
2.07 FINISHES
INDOOR FINISHES
A. Hangers and clamps for support of bare copper piping shall be coated with copper colored
epoxy paint, B-Line DURA-COPPER'". Additionally a plastic coating or a felt lining in
hanger can be used.
B. Hangers for other than bare copper pipe shall be zinc plated in accordance with ASTM
B633 - SC3 or shall have an electro-deposited green epoxy finish, B-Line DURA-GREEN".
C. Strut channels shall be pre -galvanized in accordance with ASTM A653 G90 or have
an electro-deposited green epoxy finish, B-Line DURA-GREEN.
OUTDOOR AND CORROSIVE AREA FINISHES
D. Hangers and strut located outdoors shall be hot dip galvanized after fabrication in
accordance with ASTM A123. All hanger hardware shall be hot -dip galvanized or
stainless steel. Zinc plated hardware is not acceptable for outdoor or corrosive use.
E. Hangers and strut located in corrosive areas shall be Type 304 (316) stainless steel
with stainless steel hardware.
Pipe Hangers & Supports
24
B-Line
by EA-N
Technical Data
Part III - EXECUTION
3.01 PIPE HANGERS AND SUPPORTS
A. Pipe shall be adequately supported by pipe hanger and supports specified in PART II -
PRODUCTS. Hangers for insulated pipes shall be sized to accommodate insulation
thickness.
B. Horizontal steel piping shall be supported in accordance with ANSI/MSS SP-69 & SP-58
Tables 3 and 4, excerpts of which follow below:
NOMINAL PIPE SIZE
ROD DIAMETER
MAXIMUM SPACING
3/8" - 11/4"
3/8„
7'-0„
11/2"
3/8„
91-01,
2"
3/8"
10'-0"
S
21/2"
1/2"
11'-0"
d
0 3"
1 /2"
12'-0"
d
iv 31 /2"
1 /2"
13'-0"
4"
5/8"
14'-0"
5"
5/8"
16'-0"
6"
3/4"
17'-0"
8"
3/4"
19'-0"
10"
7/8"
22'-0"
12"
7/8"
23'-0"
14"
ill
25'-0"
16"
ill
27'-0"
C. Horizontal copper tubing shall be supported in accordance with ANSI/MSS SP-69 & SP-58
Tables 3 and 4, excerpts of which follow below:
NOMINAL TUBING SIZE
ROD DIAMETER
MAXIMUM SPACING
1/4" - 3/4"
3/8„
5,-0„
ill
3/8„
6,-0„
11/4"
3/8„
7'-O„
11/2"
3/8„
8,-0„
2"
3/8„
8,-0„
21/2"
112"
9'-0"
3"
1/2"
10'-0"
31/2"
1/2"
11'-0"
4"
1 /2"
12'-0"
5"
1/2"
13'-0"
6"
5/8"
14'-0"
8"
3/4"
16'-0"
D. Provide means of preventing dissimilar metal contact such as plastic coated hangers,
copper colored B-Line DURA-COPPER" epoxy paint, or non -adhesive isolation tape
(B-Line Iso-Piper"). Galvanized felt isolators sized for copper tubing may also be used,
B-Line B3195CT.
B-Line 25 Pipe Hangers & Supports
by E.Z•N
Technical Data
E. Support horizontal cast iron pipe adjacent to each hub, with 10 feet maximum spacing
between hangers.
F. Install hangers to provide a minimum of 1/2 inch space between finished covering and
adjacent work.
G. Place a hanger within 12 inches of each horizontal elbow.
H. Support vertical piping independently of connected horizontal piping. Support vertical
pipes at every (other) floor. Wherever possible, locate riser clamps directly below pipe
couplings or shear lugs.
I. Where several pipes can be installed in parallel and at the same elevation, provide trapeze
hangers as specified in Section 2.02 C. Trapeze hangers shall be spaced according to the
smallest pipe size, or install intermediate supports according to schedule in Section 3.01 B. o
m
J. Do not support piping from other pipes, ductwork or other equipment which is not
building structure.
3.02 CONCRETE INSERTS
A. Provide inserts for placement in formwork before concrete is poured.
B. Provide inserts for suspending hangers from reinforced concrete slabs and sides of
reinforced concrete beams.
C. Where concrete slabs form finished ceilings, provide inserts to be flush with slab surface.
D. For inserts carrying 5" nominal pipe and larger, provide hooked rod to concrete
reinforcement.
Pipe Hangers &Supports B-Line
26
by EA-N
Beam Clamps
Beam clamps offered in this section are designed to provide attachment of hanger rods to structural members without
drilling or welding. A wide range of types and sizes are available for various applications.
Materials
Carbon Steel, Malleable Iron and Forged Steel are used in the manufacturing of beam clamps and accessories. Stainless
steel and other materials are available.
Finishes
The standard finishes for mechanical supports are plain steel (oil coated) sometimes referred to as black and Electro-
Galvanized Zinc (ASTM B633 SC3). Hot -Dip Galvanized After Fabrication (ASTM A123), Red Primer, Plastic Coating and
DURA-GREENT". Other special coatings are available upon request.
Note: Due to the design of some products, (threads, connecting hardware, swivels, etc.) items may
or may not be uniformly coated with special finishes. In some cases, the hanger itself may be coated, however, the
hardware may be supplied Electro-Plated, copper plated, or in stainless steel.
Recommended Set screw Torque (unless otherwise specified)
1/4"-20 3/8"-16 1/2"-13 5/8"-11 3/4"-1 O
4 ft/Ibs (5 Nm) 5 ft/Ibs (7 Nm) 11 ft/Ibs (15 Nm) 21 ft/Ibs (28 Nm) 34 ft/Ibs (46 Nm)
Over torqued set screws will damage beam clamps in this section.
We are aware that torque wrenches are not used or not available in many instances. In the absence of a torque wrench, the
set screw should be finger tightened to the I-beam and then an additional 1/4 to 1/2 turn applied to the set screw.
Approvals (as noted)
Items in this section are Underwriters Laboratories Listed, Factory Mutual Approved, and comply with Federal Specification
WW-H-171 E & A-A-1192A or Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
by -Line by E:T-N 27 Pipe Hangers & Supports
Beam Clamps
B351 L - Steel C-Clamp With Locknut (TOLCO Fig. 64)
Size Range: 3/8"-16 thru 7/8"-9 rod
Material: Steel
Function: For attachment to I -beams, channels, and wide flange beams
where the thickness does not exceed 3/4" (1g.omm). Hardened set screw
secures "C" Clamp to beam.
Approvals: B351 L (3/8"-16 - 3/4"-10), is Underwriters Laboratories Listed.
Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 23 and
Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 23.
Finish: Plain. Contact B-Line for alternative finishes and materials.
Note: When retaining strap is required, order B3362 thru B3365 separately.
See page 29.
Order By: Part number and finish
B3O36L - Malleable Iron C-Clamp With Locknut
c &us
LISTED
D
B
f:
c
Set Screw and
Locknut Included
A
(Rod Size)
Hanger Rod
Not Included
Size Range: 3/8"-16 thru 3/4"-10 rod
ce us
Material: Malleable Iron
LISTED
Set Screw and
9/4"
Function: Designed for attaching a hanger rod to the flange of a beam.
Locknut Included (ts.o)
Approvals: B3036L is Underwriters Laboratories Listed. Complies
A
with Federal Specification WW-H-171 E & A-A-1192A Type 23 and
(Rod size)
B
Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58 Type 23.
Hanger Rod
Finish: Plain or Electro-Galvanized
Not Included
Order By: Part number and finish. When retaining strap is
required, order B3362 thru B3365 separately. See page 29.
Note: See page 27 for recommended setscrew torque.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
28
B-Line
by Ect•N
Beam Clamps
133362, 133363, 133364, B3365 - Retaining Strap
Size Range: 6" (152.4mm) to 12" (304.8mm)
lengths
Material: Steel (Stainless Steel available)
Finish: Pre -Galvanized
Function: Designed for use with B351 L
and B3036L C-Clamps.
Order By: Part number, length 'L', (add
1 " (25.4) minimum to flange width), and
finish.
Note: Requires field forming on beam.
B3037 - Z-Purlin Malleable C-Clamp
Material: Malleable Iron
Function: Designed for attaching a 3/8"-16 hanger rod to the
bottom flange of a Z-purlin.
Approvals: Underwriters Laboratories Listed for up to 4" (loomm)
pipe. Conforms to Federal Specification WW-H-171 E & A-A-1192A,
Type 23 and Manufacturers Standardization Society ANSI/MSS
SP-69 & SP-58, Type 23.
Finish: Plain or Electro-Galvanized
Order By: Part number and finish.
Weight: Approx. Wt./100 90 Lbs. (40.8kg)
Design Load: 400 Lbs. (1.78kN)
Note: See page 27 for recommended setscrew torque.
C &us
LISTED
3"
(76.2)
Throat Opening
31/32" (24.6)
Bottom Hanger Rod
Threads
3/s"-16
Material Thickness
12 Gauge (2.7)
313/3211
(86.5)
Set Screw and
Locknut Included
B-Line
by E:T-N
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
29
Pipe Hangers & Supports
Beam Clamps
B3031-3/8 - Light Duty Malleable C-Clamp
Material: Malleable Iron
Function: Designed for attaching a 3/8"-16 hanger rod to the top or 11/2"
bottom flange of a beam or bar joist when setscrew is in the down position (38.1)
as shown.
Approvals: Underwriters Laboratories Listed for up to 4" pipe. Conforms
to Federal Specification WW-H-171 E & A-A-1192A, Type 19 and
Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 19.
Finish: Plain or Electro-Galvanized
Order By: Part number and finish. When retaining strap is required,
order Fig. 69 separately. See Page 37.
Weight: Approx. Wt./100 25 Lbs. (11.3kg)
Design Load: 350 Lbs. (1.55kN)
Note: See page 27 for recommended setscrew torque.
B3O33 - Wide Jaw Reversible C-Clamp (TOLCO Fig. 68)
Size Range: 3/8"-16 thru 3/4"-10 rod
3/4"
(19.0)
c @us
(47.5) LISTED
Throat Opening
.� 11/16" (17.5)
Material: Cast Malleable Steel with hardened cup point set screw
and jam nut
Function: For attachment to structural shapes requiring wider throat Throat Opening
especially under roof with bar joist construction. 11/4" (31.7) for B3033-3/8 & 1h
This clamp may be used with the set screw in the up or down position. 15/15" (33.3) for B3033-5/8 & 3/4
Approvals: Underwriters Laboratories Listed (cULus) and Factory
Mutual Engineering Approved (FM). Conforms to Federal Specification
WW-H-171 E Type 19 & A-A-1192A, Type 19 & 23 and Manufacturers
Standardization Society ANSI/MSS SP-69 & SP-58, Type 19 & 23. rY
Finish: Plain. Contact B-Line for alternative finishes and -
materials.
Order By: Part number, rod size and finish -
Note: Do not over tighten set screw. "'•�
Top Flange Attachment
Applications
Note: See page 27 for recommended setscrew torque.
Hanger Rod Set Screw and
Not Included Locknutlncluded
C O
B
sue —
Set Screw and
Locknutlncluded
C&S <FM>
LISTED°°--D
Bottom Flange Attachment
Applications
A
(Rod Size)
Hanger Rod
Not Included
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
30
B-Line
by Ect•N
Beam Clamps
B3034 - C-Clamp
Size Range: 3/8"-16 thru 3/4"-10 rod
Material: Cast Malleable Steel with hardened cup point set
screw and jam nut
Function: Recommended for hanging from steel beam
where flange thickness does not exceed 3/4" (19.0mm).
Features: May be used on top or bottom flange of the
beam. Beveled lip allows hanging from top flange where
clearance is limited. may be installed with the set screw in
the up or down position. Offset design permits unlimited rod
adjustment by allowing the rod to be threaded completely
through the clamp. The rear window design permits
inspection of thread engagement.
Approvals: Underwriters Laboratories Listed and Factory
Mutual Engineering Approved for 3/8"-16 and 1/2"-13 rod
sizes. Conforms to Federal Specification WW-H-171 E &
A-A-1192A, Type 19 & 23 and Manufacturers
Standardization Society ANSI/MSS SP-69 & SP-58, Type
19 & 23. 3/8"-16 is (cULus) Listed to support up to
4" (100mm) pipe with the set screw in the down position,
up to 3" (75mm) pipe with the set screw in the up position.
1/2"-13 is (cULus) Listed to support up to 8" (200mm) pipe
with the set screw in the down position, up to 6" (150mm)
pipe with the set screw in the up position.
Finish: Plain. Contact B-Line for alternative finishes and
materials.
Order By: Part number and finish
B3034-5/8" and B3034-3/4" sizes
Attach only as shown.
C
DD �
Throat
Opening
3/4" (19.0)
A
(Rod Size)
Hanger Rod
W' = Not Included
Set Screw and
Locknutlncluded
Note: See page 27 for recommended setscrew torque.
ells
LISTED
FM �
Throat
Opening
3/4" (19.0)
133034-3/8" and B3034-1/2" sizes
Attach only as shown.
C
Set Screw and
Locknutlncluded
Top Flange
Attachment
Applications
Bottom Flange
Attachment
Applications
A
(Rod Size)
Hanger Rod
Not Included
B-Line
by E:TlN
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
31
Pipe Hangers & Supports
Beam Clamps
Fig. 68S - Reversible Malleable Beam Clamp 3/41' (19.omm) Throat Opening
Fig. 68W - Reversible Malleable Beam Clamp 11/4" (31.7mm) Throat Opening (bottom of page)
Size Range: (g)TDLCC3
3/8"-16 rod sizes thru 7/8"-9 rod sizes FM
Material: Cast Malleable Steel with hardened cup point set screw and jam nut
Function: Recommended for hanging from steel beam where flange thickness does
not exceed 3/4" (19.omm) on Fig. 68S or 11/4" (31.7mm) on Fig.68W.
Features: May be used on top or bottom flange of beam. Beveled lip allows hanging
from top flange where clearance is limited. May be installed with set screw in up or
down position. Offset design permits unlimited rod adjustment by allowing the rod to
be threaded completely through the clamp. The rear window design permits inspection
of thread engagement.
Approvals: Factory Mutual Engineering Approved. Underwriters Laboratories Listed.
Conforms to Federal Specification WW-H-171 E, Type 23 and Manufacturers
Standardization Society SP-58, Type 19.
Fig. 68S-3/8 is cULus Listed to support up to 4" (100mm) pipe with the set screw
in the down position and up to 3" (80mm) pipe with the set screw in the up position.
Fig. 68S-1/2 is cULus Listed to support up to 8" (200mm) pipe with the set screw
in the down position and up to 6" (150mm) pipe with the set screw in the up position.
Fig. 68W-3/8 is cULus Listed to support up to 4" (100mm) pipe with the set screw
in the down position and up to 4" (loomm) pipe with the set screw in the up position.
Fig. 68W-1/2 is cULus Listed to support up to 6" (150mm) pipe with the set screw
in the down position and up to 6" (15omm) pipe with the set screw in the up position.
Factory Mutual Engineering approved only with the set screw in the down position.
(OSHPD). For additional load spacing and placement information relating
OSHPD projects, please refer to the Seismic Restraint System Guidelines.
Finish: Plain. Contact B-Line for Electro-Galvanized or HDG finishes.
Order By: Part number and finish Fig. 68S Fig. 68W
. a + +
aw
Fig. 68S
A
(Rod'
Hange
Not Inc
c &GIs
LISTED
Fig. 68S Set Screw and
Locknutlncluded
D = Depth of Throat
A
(Rod Size) G•
Hanger Rod w
Not Included
Fig. 68W
Set Screw and
Locknutlncluded
Part
i
68S-%
'ii
3/8"-16
Size
19/16"
B
(39.7)
Min.
3/4"
C
(19.0)
11/8"
1
(28.6)
7/16"
E
(11.1)
F
7/8"
(22.2)
Max Rec.
Set Screw
610
Load
Up
(2.71)
Max Rec.
Set Screw
610
Load
li
(2.71)
Approx.
II
32 (14.5)
68S-1/2
1/2"-13
15/8"
(41.3)
3/4"
(19.0)
1"
(25.4)
7/16"
(11.1)
11/8"
(28.6)
750
(3.33)
1130
(5.02)
54
(24.5)
68S-5/8
5/8"-11
19/16"
(39.7)
3/4"
(19.0)
1"
(25.4)
9/16"
(14.3)
11/8"
(28.6)
750
(3.33)
1130
(5.02)
50
(22.7)
68S-3/4
3/4"-10
13/4"
(44.4)
3/4"
(19.0)
11/8"
(28.6)
9/16"
(14.3)
11/4"
(31.7)
750
(3.33)
1130
(5.02)
81
(36.7)
68S-7/8
7/8"-9
1 13/4"
(44.4) 1
3/41,
(19.0)
1 11/81,
(28.6)
9/16"
(14.3) 15/16"
(33.3) 1
750
(3.33)
1 1130
(5.02) 1
75
(34.0)
Fig. 68W
Note: See page 27 for recommended setscrew torque.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
32
B-Line
by IFA-N
Beam Clamps
Fig. 65 - Reversible Steel C-Type Beam Clamp 3/411 (19.omm) Throat Opening
Fig. 65XT - Reversible Steel C-Type Beam Clamp 3/41, (19.omm) Throat Opening (bottom of page)
Size Range:
Fig. 65 - 1/2"-13 rod sizes, and 5/8"-11 rod sizes (8)TOLCO
Fig. 65XT - 3/8"-16 rod size (see below)
Material: Steel with hardened cup point set screw and jam nut
Function: Recommended for hanging from steel beam where flange thickness does
not exceed 3/4" (19.0mm).
Features: All steel construction eliminates structural deficiencies associated with
casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip
allows hanging from top flange where clearance is limited.) May be installed with set
screw in up or down position. Offset design permits unlimited rod adjustment by
allowing the rod to be threaded completely through the clamp. Open design permits
inspection of thread engagement.
Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL).
Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13,
3/8"-16 rod will support 1/2" (15mm) thru 4" (1o0mm) pipe
1/2"-13 rod will support 112" (15mm) thru 8" (200mm) pipe
Included in the Seismic Restraints Catalog approved by the State of California
Office of Statewide Health Planning and Development (OSHPD). For additional
load spacing and placement information relating OSHPD projects, please refer to
the Seismic Restraint System Guidelines.
Finish: Plain. Contact B-Line for alternative finishes and materials.
Order By: Part number and finish
Fig. 65 Patent #4,570,885
Part F Mac Rec. Load * Approx. Wt./100
No. in. (mm) in. (mm) in. (mm)
Maximum loads for clamp with set screw in up or down position.
Note: See page 27 for recommended setscrew torque.
Fig. 65XT-3/8 - Beam Clamp
Feature: Extruded holes allow for more thread
engagement of threaded rod and set screw.
Weight: Approx. Wt./100 - 28.0 Lbs. (12.7kg)
Design Load: 730 Lbs (3.25kN)
Finish: Plain or Electro-Galvanized
Order By: Part number and finish
Approvals: Underwriters Laboratories Listed
and FM Approved for uo to 4" (100mm) pipe.
Component of State of
California OSHPD Approved
Seismic Restraints System
C &us
LISTED
Set Screw and
Locknut Included
11/8..
C&S �FMo (PTOLCO /�(28.6)
LISTED
19/16"
5� /1
3/�. y /
3/411 A��PAN
(19.0)
Set Screw and 7/8"
Locknut Included 13/8" (zz.z)
134.91
Note: See page 27 for recommended setscrew torque.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
B-Line by E:TlN 33 Pipe Hangers & Supports
Beam Clamps
Fig. 66 - Reversible Steel C-Type Beam Clamp 11/4" (31.7mm) Throat Opening
Size Range: 3/8"-16, 1/2"-13 rod sizes, and 5/8"-11 rod sizes
Material: Steel with hardened cup point set screw and jam nut
Function: Recommended for hanging from steel beam where flange
thickness does not exceed 11/4" (31.7mm).
Component of State of
(g)TDLC0California OSHPD Approved
Seismic Restraints System
Features: All steel construction eliminates structural deficiencies associated with
casting type beam clamps. May be used on top or bottom flange of beam. (Beveled
lip allows hanging from top flange where clearance is limited.) May be installed with
set screw in up or down position. Offset design permits unlimited rod adjustment by
allowing the rod to be threaded completely through the clamp. Open design permits
inspection of thread engagement.
Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (WL).
Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13,
3/8"-16 rod will support 1/2" (15mm) thru 4" (100mm) pipe
1/2"-13 rod will support 1/2" (15mm) thru 8" (200mm) pipe
Included in the Seismic Restraints Catalog approved by the State of California
Office of Statewide Health Planning and Development (OSHPD). For additional
load spacing and placement information relating OSHPD projects, please refer to
the Seismic Restraint System Guidelines.
Finish: Plain. Contact B-Line for alternative finishes and materials.
Order By: Part number and finish
' Maximum loads for clamp with set screw in up or down position.
Note: See page 27 for recommended setscrew torque.
ClVL1N5
Set S[
Locknu
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
34
B-Line
by Ect•N
Beam Clamps
Size Range: 3/8"-16 and 1/2"-13 rod sizes
Material: Stainless Steel (Type 316 or 304)
Fig. 67SS - Stainless Steel Reversible C-Type Beam Clamp 3/4" (19.omm) Throat Opening
Fig. 68SS - Stainless Steel Reversible C-Type Beam Clamp Wide Mouth
c &GIs
LISTED
tTOLC❑
Function: Recommended for hanging from steel beams where flange thickness does
not exceed 3/4" (19.0mm) for Fig. 67SS or 11/4" (31.7mm) for Fig. 68SS.
Features: All steel construction eliminates structural deficiencies associated with
casting type beam clamps. May be used on top or bottom flange of beam. May be
installed with set screw in up or down position. Offset design permits unlimited rod
adjustment by allowing the rod to be threaded completely through the clamp.
Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL).
Conforms to Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58,
Type 19. Meets or exceeds requirements of the National Fire Protection Association
(NFPA), pamphlet 13.
3/8"-16 rod will support 1/2" (15mm) thru 4" (loomm) pipe
1/2"-13 rod will support 1/2" (15mm) thru 8" (200mm) pipe
Order By: Part number and stainless steel type.
icrew and
Locknut Included
Fig. 67SS
i
A
Part F G Test Load Approx.11
67SS-% 15/8" (41.3) 11 /8" (28.6) 1500 (6.67) 84 (38.1)
67SS-1/2 15/8" 1 (41.3) 11 /8" (28.6) 4050 (18.01) 170 (77.1)
I ;
-�_
Fig. 68SS
Part F Test Load Approx.11
68SS-3/8 2" (50.8) 1500 (6.67) 84 (38.1)
68SS-1/2 21 /4" (57.1) 1 4050 (18.01) 170 (77.1)
Note: See page 27 for recommended setscrew torque.
E —
G —
C F
I T
B-Line
by E:TlN
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
35
Pipe Hangers & Supports
Beam Clamps
B303-B309 - Beam Clamps
Size Range: 1/4"-20 thru 5/8"-11 rod
Material: Steel
Function: Designed for attaching a hanger rod to the flange of a beam.
Approvals: Conforms to Federal Specification WW-H-171 E & A-A-1192A,
Type 19 and Manufacturers Standardization Society ANSI/MSS SP-69 &
SP-58, Type 19.
Finish: Elect ro-Galvan ized or Hot -Dip Galvanized
Order By: Part number and finish. When retaining strap is required, order
B312 separately. See page 39.
Recommended Set Screw Torque:
3/8"-16 = 150 in-Ibs (16.9 N•m)
1/2"-13 = 350 in-Ibs (39.5 N•m)
_ I Set Screw
Included
7/8" (22.2)
Maximum
Flange
Thickness
Part
B303
B304
Rod
1/4"-20
5/16"-18
Size
Setscrew
3/8"-16
3/8"-16
25/16"
25/16"
C
(58.7)
(58.7)
T
11 Ga.
11 Ga.
(3.0)
(3.0)
Design
400
600
Load
(1.78)
Approx.
72
Wt./100
(32.6)
(2.67) 72
(32.6)
B305
3/8"-16
3/8"-16
25/16"
(58.7)
11 Ga.
(3.0)
600
(2.67)
72
(32.6)
B306
3/8"-16
1/2"-13
27/16"
(61.9)
7 Ga.
(4.5)
1100
(4.89)
97
(44.0)
B307
1/2"-13
1/2"-13
27/16"
(61.9)
7 Ga.
(4.5)
1100
(4.89)
97
(44.0)
B308
1/2"-13
1/2"-13
29/16"
(65.1)
1/4"
(6.3)
1500
(6.67)
133
(60.3)
B309
5/8"-11
1/2"-13
1 29/16"
1 (65.1)
1/4"
(6.3)
1 1500
(6.67)
1 133
(60.3)
Fig. B321 - Series Beam Clamps Set Screw
Size Range: 3/8"-16 thru 3/4"-10 rod Included
Material: Steel
Function: Designed for attaching a hanger rod to the flange of a beam.
Approvals: Conforms to Federal Specification WW-H-171 E & 111/16" (42.8)
A-A-1192A, Type 19 and Manufacturers Standardization Society Maximum
Flange
ANSI/MSS SP-69 & SP-58, Type 19. Thickness
Finish: Elect ro-Galvanized or Hot -Dip Galvanized
Ordering: Part number and finish. When retaining strap is required,
order B312 separately. See page 39.
Recommended Set Screw Torque:
1/2"-13 = 350 in-Ibs (39.5 N•m) '
5/8"-11 = 700 in-Ibs (79.0 N•m) _�
r�
Minimum Flange Thickness:
For B321-1 thru B321-3 = 3/81, (9.5)
For B321-4 & B321-5 = 5/8" (15.9)
Part
B321-1
Rod
3/8"-16
Size
Setscrew
1/2"-13
G
39/16"
(92.1)
1/4"
T
(6.3)
Design
1300
Load
(5.78)
Approx.
187
Wt./100
(84.8)
B321-2
1/2"-13
1/2"-13
39/16"
(92.1)
1/4"
(6.3)
1400
(6.23)
186
(84.3)
B321-3
5/8"-11
1/2"-13
39/16"
(92.1)
1/4"
(6.3)
1600
(7.12)
185
(83.9)
B321-4
5/8"11
5/8"-11
323/32"
(94.4)
5/16"
(7.9)
1800
(8.00)
239
(108.4)
B321-5
3/4"-10
5/8"-11
323/32"
(94.4)
5/16"
(7.9)
2000
(8.89)
238
(107.9)
,8n
.3)
A
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
36
B-Line
by Ect•N
Beam Clamps
Fig. 69 - Beam Clamp Retaining Strap (B-Line 1333167)
Size Range: 3/8"-16 thru 3/4"-10 rod
4" (101,6mm) thru 16" (406.4mm) lengths
Note: longer lengths are available consult factory
Material: Pre -Galvanized Steel
Function: To offer more secure fastening of various types of
beam clamps to beam where danger of movement might be
expected. NFPA 13 requires the use of retaining straps with
all beam clamps installed in earthquake areas. Satisfies
requirements of NFPA 13.
Important Note: Good installation practice of a retaining
strap requires that the strap be held tightly and securely to all
component parts of the assembly. Therefore a locking
mechanism of some kind, such as a hex nut or the beveled
locking slot of the Fig. 69R will provide a more secure reliable
installation.
Approvals: Underwriters Laboratories Listed in the USA (UL)
and Canada (WL). Approved for use with any listed beam
clamp. Included in the Seismic Restraints Catalog approved
by the State of California Office of Statewide Health Planning
and Development (OSHPD). For additional load spacing and
placement information relating OSHPD projects, please refer
to the Seismic Restraint System Guidelines.
Finish: Pre -Galvanized
Order By: Part number, length (L), and finish.
Note: Minimum return on strap is 1" (25.4mm)
C
Component of State of
11� California OSHPD Approved
US Y Seismic Restraints System
LISTED
TOLC0_
B-Line
by E:T-N
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
37
Pipe Hangers & Supports
Beam Clamps
Fig. 69R - Retrofit Capable Beam Clamp Retaining Strap
Size Range: 3/8"-16 & 1/2"-13 rod Component of State of
4" 101,6mm thru 16" 406.4mm lengths (g)TCILCC7 C �� US California OSHPD Approved
( ) ( ) g LISTED
Seismic Restraints System
Note: longer lengths are available consult factory
Material: Pre -Galvanized Steel
Function: To offer more secure fastening of various types of
beam clamps to beam where danger of movement might be
expected. NFPA 13 requires the use of retaining straps with
all beam clamps installed in earthquake areas. Satisfies
requirements of NFPA 13.
Features: Beveled locking slot* is precisely formed to align
with the threaded section of a hanger rod or set screw and
engage the unit securely. May be used as shown in Section
"A -A" or inverted. Allows easy installation for new construction
or retrofit applications.
Important Note: Good installation practice of a retaining
strap requires that the strap be held tightly and securely to all
component parts of the assembly. Therefore a locking
mechanism of some kind, such as a hex nut or the beveled
locking slot of the Fig. 69R will provide a more secure reliable
installation.
Approvals: Underwriters Laboratories Listed in the USA (UL)
and Canada (WL). Approved for use with any listed beam
clamp. Included in the Seismic Restraints Catalog approved
by the State of California Office of Statewide Health Planning
and Development (OSHPD). For additional load spacing and
placement information relating OSHPD projects, please refer
to the Seismic Restraint System Guidelines.
Finish: Pre -Galvanized
Order By: Part number, length, and finish.
Note: Minimum return on strap is 1" (25.4mm)
* Patent #5,947,424
A -A
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
B-Line
Pipe Hangers & Supports 38
by Ect•N
Beam Clamps
B312 - Retaining Strap
Size Range: 9" (228.6mm) to 18" (457.2mm) strap lengths
Material: Steel
Function: Designed for use with 13303-6309 and B321 beam clamps.
Finish: Pre -Galvanized
Order By: Part number and finish.
Notes:
Maximum beam thickness 3/4" (19.0).
For thicker beams step up one flange width size.
Requires field forming on beam.
Material Thickness
14 Gauge (1.9) 13/4--
L (44.4)
1/2
1 1/4"
(12.7)
(31.7) 1/4
(6.3)
I�
II
I,
II
B-Line
by E:T-N
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
39
Pipe Hangers & Supports
Beam Clamps
B3O5O - Beam Clamp (TOLCo Fig. 62) A
Center of bolt to bottom of beam ; ' Steel Size
Material: Steel flange. I I
Function: Recommended for the suspending of hanger rod from
the center of an I-beam, equally distributing the load on both sides A
of the beam. Use with B3210 eye rod, B3211 welded eye rod
or B3200 weldless rye nut. Bolt and Nut Included
Approvals: Conforms to Federal Specification WW-H-171 E & A-A-1192A,
Type 21 and Manufacturers Standardization Society ANSI/MSS SP-69 & Bolt size
SP-58, Type 21.
Finish: Plain. Contact B-Line for alternative finishes and materials.
Order By: Part number, type, width of flange and finish. B
4"
(101.6)
Flange
3/16" (4.8)
Thickness
1/2" (12.7)
Approx.II For
116 (52.6)
(194.6)
429
5"
(127.0)
5/16"
(7.9)
5/8" (15.9)
125
(56.7)
458
(207.8)
6"
(152.4)
1/4"
(6.3)
3/4" (19.0)
134
(60.8)
486
(220.5)
7"
(177.8)
7/16"
(11.1)
7/8" (22.2)
143
(64.9)
514
(233.2)
8"
(203.2)
7/16"
(11.1)
7/8" (22.2)
152
(69.0)
543
(246.3)
9"
(228.6)
9/16"
(14.3)
ill (25.4)
160
(72.6)
571
(259.0)
10"
(254.0)
5/8"
(15.9)
ill (25.4)
169
(76.7)
599
(271.8)
12"
(304.8)
5/8"
(15.9)
11/4" (31.7)
187
(84.8)
656
(297.6)
B3O4O - Adjustable Beam Clamp (TOLCO Fig. 336)
Size Range: 3/8"-16 thru 3/4"-10 rod
Material: Steel
Function: Fits structural I -Beams and wide flange beams, flange
widths 31/2" (88.9mm) to 8" (203.2mm), thickness Up to 1/2" (12.7mm).
Approvals: Conforms to Federal Specification WW-H-171 E &
A-A-1192A, Type 54, and Manufacturers Standardization Society
ANSI/MSS SP-69 & SP-58, Type 27.
Finish: Plain. Contact B-Line for alternative finishes and materials.
Order By: Part number and finish
J-Hook and Hex
Nut Included
C
Center of J-Hook to bottom
of clamp body.
1- A
(Rod Size)
Hanger Rod
Not Included
C
B
Steel Size
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
40
B-Line
by E:J-N
Beam Clamps
B3055 - Steel Beam Clamp
Size Range: 3/8"-16 thru 1 "-8 rod
Material: Steel
Function: Designed for attaching a hanger rod to be centered under beam flanges.
2" (50.8mm) vertical adjustment is provided in the clamp.
Approvals: Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 21
and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 21.
Finish: Plain or Electro-Galvanized
Order By: Part number, flange width, and finish.
Steel Size
Size
Bolt and Nut Included
B
B
Center of cross bolt to
bottom of side of hanger
_ ,
rod nut.
A
(Rod Size)
NOTE:
Hanger Rod
Slots on bottom
Not Included
portions of clamp halves allow
-- 1" (25.4) adjustment for
variance in flange widths
Hanger Rod
Not Included
C
Rod Size
B3055-3/8 3/8"-16
3"
B
(76.2)
C
4" (101.6)
Steel
1/4" x 11/4"
Size
(6.3 x 31.7)
Design
550
Load
(2.44)
B3055-1/2 1/2"-13
3"
(76.2)
4" (101.6)
1/4" x 11/2"
(6.3 x 38.1)
850
(3.78)
B3055-5/8 5/8"-11
31/4"
(82.5)
41/2" (114.3)
3/8" x 11/2"
(9.5 x 38.1)
1100
(4.89)
B3055-3/4 3/4"-10
31/4"
(82.5)
41/2" (114.3)
3/8" x 2"
(9.5 x 50.8)
1500
(6.67)
B3055-7/8 1 7/8"-9
31/2"
(88.9)
5" (127.0)
1/2" x 2"
(12.7 x 50.8)
2600
(11.56)
B3055-1 1 "-8
31/2"
(88.9)
51/2" (139.7)
1/2" x 21/2"
(12.7 x 63.5)
4300
(19.12)
Note:
Box Style
Furnished For
B3055 3/s x 2"
B3055 3/s x 3"
B3055 3/s x 4"
B3055 1/2 x 2"
B3055 1/2 x 3"
B3055 1/2 x 4"
B3055-5/8 x 2"
B3055-5/8 x 3"
B3055-5/8 x 4"
B3055 3/4 x 2"
B3055 3/4 x 3"
B3055 3/4 x 4"
B3055-7/8 x 3"
B3055-7/8 x 4"
B3055-7/8 x 5"
B3055-1 x 3"
B3055-1 x 4"
B3055-1 x 5"
B3055-1 x 6"
B3055-11/8 x 4"
B3055-11/8 x 5"
B3055-11/8 x 6"
B3055-11/8 x 7"
B3055-11/4 x 4"
B3055-11/4 x 5"
B3055-11/4 x 6"
B3055-11/4 x 7"
,e
4--
Width W
(101.6)
I
168
(76.2)
ApproximateII
I
201 (91.2)
For Beam
I
328 (148.8)
Clamp Size Lbs.
I
434 (196.8)
(kg)
IB3055-1
657 (298.0)
797 (361.5)
5"
(127.0)
181
(82.1)
217
(98.4)
352
(159.6)
466
(211.4)
667
(302.5)
824
(373.7)
6--
(152.4)
193
(87.5)
231
(104.8)
373
(169.2)
495
(224.5)
705
(319.8)
877
(397.8)
T-
(177.8)
205
(93.0)
246
(111.6)
395
(179.2)
525
(238.1)
744
(337.5)
926
(420.0)
8"
(203.2)
214
(97.1)
256
(116.1)
411
(186.4)
546
(247.6)
773
(350.6)
962
(436.3)
10"
(254.0)
235
(106.6)
282
(127.9)
449
(203.6)
596
(270.3)
840
(381.0)
1046
(474.4)
12"
(304.8)
259
(117.5)
311
(141.0)
493
(223.6)
655
(297.1)
918
(416.4)
1143
(518.4)
B-Une
by FIT-N
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
41
Pipe Hangers & Supports
Beam Clamps
B3054 - Malleable Iron Beam Clamp With Extension
B3054WO - Malleable Iron Beam Clamp Without Extension JOLCO Fig. 329)
Size Range: 3/8"-16 thru 7/8"-9 rod
Material: Malleable Iron C 0L u5
LISTED
Function: Designed for attaching a hanger rod to the bottom
flange of a beam. Adjustable for flange widths of 3" (76.2mm) to
7" (177.8mm) and a flange thickness of no greater than 5/8" (15.9mm).
Approvals: Underwriters Laboratories Listed. Conforms to
Federal Specification WW-H-171 E & A-A-1192A, Type 30 and
Manufacturers Standardization Society ANSI/MSS SP-69 &
SP-58, Type 30.
Finish: Plain or Electro-Galvanized
Ordering: Part number and finish
IWO
B3054
Clamping Rod and Nuts
Included
E
Rod Take -Out
A
(Rod Size)
Hanger Rod Not
Included
B3054-3/8
Rod
Size
3/8"-16
411/16"
(119.1)
49/16"
Rod Take Out
(115.9)
'E' For
45/8"
Beam Flange
(117.5)
Width
4"
Of
(101.6)
31/8"
19
(79.4)
B3054-1/2
1/2"-13
413/16"
(122.2)
41/2"
(114.3)
45/16"
(109.5)
315/16"
(10Q0)
31/4"
(82.5)
B3054-5/8
5/8"-11
47/8"
(123.8)
45/8"
(117.5)
43/8"
(111.1)
33/4"
(95.2)
35/16"
(84.1)
B3054-3/4
3/4"-10
51/8"
(130.2)
5"
(127.0)
45/8"
(117.5)
41/4"
(107.9)
33/4"
(95.2)
B3054-7/8
7/8"-9
53/16"
(131.8)
47/8"
(123.8)
411/16"
(119.1)
45/16"
(109.5)
33/4"
(95.2)
B3054-3/8
Design
730
Load
(3.25)
Max. Iran Pipe
4"
Size Per UL
(100)
Approx.
236
Wt./100
(107.0)
B3054-1/2
1350
(6.00)
8"
(200)
254
(115.2)
B3054-5/8
1365
(6.07)
10"
(250)
260
(117.9)
B3054-3/4
1365
(6.07)
10"
(250)
278
(126.1)
B3054-7/8
1365
(6.07)
10"
(250)
292
(132.4)
E
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
42
B-Line
by E:T■N
Beam Clamps
B3291, B3292, B3293, B3294, B3295, B3296, B3297, B3298
UFS Beam Clamp With Weldless Eye Nut
Available with left hand threads by adding an L to part number Example: B3291L-*
Size Range: 3/8"-16 thru 2"-41/2 rod
Material: Forged Steel
Function: Designed for attaching a hanger rod to the
bottom flange of a beam. Adjustable from flange widths
of 3" (76.2mm) to 15" (381.0mm). and flange thickness of
no greater than 11/32" (26.2mm).
Approvals: Complies with Federal Specification
WW-H-171 E & A-A-1192A (Type 28 without links;
Type 29 with links,) and ANSI/MSS SP-58 (Type 28
without links; Type 29 with links).
Finish: Plain or Electro-Galvanized
Order By: Part number, rod size and finish.
Note: Design load for B3291 thru B3295 based on
maximum rod size shown. Use the appropriate all
threaded rod design load shown on page 300 for sizes
less than maximum.
s
Maximum
Beam
Flange
Rod Size A
Part No.
Thickness
(Specify)
B
C
Design
Load
Approx.
Wt./1 11
'id
B3291 *
.60
(15.2)
3/8"-16,1/2"-13,
5/8"-11 3/4"-10
11/4"
(31.7 )
11/8"
(28.6)
3230
(14.36)
390
(176.9)
B3292-*
.60
(15.2)
7/8"-9, 1 "-8
111/16"
(42.9)
11/8"
(28.6)
5900
(26.24)
915
(415.0)
B3293-*A
.60
(15.2)
3/8" 16,1/2"-13, 5/8" 11,
111/16"
(42.9)
11/8"
(28.6)
5900
(26.24)
1300
(589.6)
3/4"-10, 7/8"-% 1 "-8
B3294-*
1.031
(26.2)
7/8"-%1"-8
11/2"
(38.1)
11/8"
(28.6)
5900
(26.24)
2165
(982.0)
B3295-*A
1.031
(26.2)
7/8"-9, 1"-8
11/2"
(38.1)
11/8"
(28.6)
5900
(26.24)
3385
(1535.4)
B3296-*
1.031
(26.2)
1"-8, 11/8"-7,
21/8"
(54.0)
11/8"
(28.6)
11500
(51.15)
2390
(1084.1)
11/4"-7, 11/2"-6
B3297-*A
1.031
(26.2)
11/8"-7, 11/4"-7, 11/2"-6
21/8"
(54.0)
11/8"
(28.6)
11500
(51.15)
3575
(1621.6)
B3298-*
1.031
(26.2)
13/4"-5, 2"-41/2
49/16"
1 (115.9)
11/8"
1 (28.6)
11500
(51.15)
3675
1 (1666.9)
B3291 *
41/2"
55/16"
41/16"
35/8"
27/8"
Rod Take
--
-Out ForFlange
--
I
-
--
-
--
--
B3292-*
-
43/4"
47/16"
41/16"
33/8"
--
--
--
-
--
--
--
--
B3293-*A
--
--
-
515/16"
6"
55/16"
511
-
--
--
--
--
B3294-*
--
613/16"
65/8"
63/81,
57/8"
57/811
53/8"
413/16"
--
--
--
--
--
B3295-* A
81/8"
73/4"
71/8"
65/8"
61/16"
B3296-*
--
73/16"
7"
63/4"
61/4"
65/16"
513/16"
53/16"
-
--
--
--
--
B3297-* A
81/2"
81/8"
71/2„
7"
67/16"
B3298-*
--
83/8"
87/16"
83/16"
73/4"
73/4"
71/4"
65/81,
--
--
--
--
To determine (mm) in the above chart, multiply inches by 25.4.
Rod Size required to finish part number (see Rod Size 'A' in top chart).
A These part numbers are furnished with links.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
B-L�ne
by FIT -IN
43 Pipe Hangers & Supports
Beam Clamps
B3042 - Top Beam Hook (TOLCO Fig. 61)
Size Range: 3/8"-16 and 1/2"-13 rod
Material: Steel
Function: Designed for attaching hanger rod to the top flange
of a beam or angle truss. The support rod completes assembly
and secures it to the flange.
Finish: Plain or Elect ro-Galvanized
Order By: Part number flange width, flange thickness and
finish.
A
(Rod Size)
Hanger Rod
Not Included
Allows 1/8" (3.2) clearance between hanger rod and
flange of beam.
For Pipe Size Design Load
B3042-3/8 3/8"-16 3/4"-2" (20-50) 300 (1.33)
B3042-1/2 1/2"-13 21/2 31/2 (65-90) 500 (2.22)
B3045 - Side Beam Clamp (TOLCO Fig. 335)
Size Range: 3/8"-16 thru 7/8"-9 rods
3" (76.2mm) thru 9" (228.6mm) flange widths
Material: Steel
Function: Designed for attaching hanger rod to the side of a beam
flange. Works on top or bottom of beam.
Approvals: Conforms to Federal Specification WW-H-171 E &
A-A-1192A, Type 53 and Manufacturers Standardization Society
ANSI/MSS SP-69 & SP-58, Type 25.
Finish: Plain or Electro-Galvanized
Order By: Part number, flange width and thickness, and finish
A (Rod Size)
Hanger Rod Not Included if
B
B3045-3/8
Rod
3/8"-16
Size
B
21/16"
(52.4)
3"
Flange
- 9"
Width
(76.2 - 228.6)
Design
300
Load
(1.33)
B3045-1/2
1/2"-13
25/16"
(58.7)
3"
- 9"
(76.2 - 228.6)
500
(2.22)
B3045-5/8
5/8"-11
27/16"
(61.9)
3"
- 9"
(76.2 - 228.6)
700
(3.11)
B3045-3/4
5/8"-11
27/8"
(73.0)
3"
- 9"
(76.2 - 228.6)
800
(3.55)
B3045-7/8
5/8"-11
3"
(76.2)
1 3"
- 9"
(76.2 - 228.6) 1
1200
(5.33)
Bolt and Nut Included
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
44
B-Line
by Ect•N
Beam Clamps
B3042T - Bar Joist Hanger (TOLCO Fig. 61T)
Size Range: 3/8"-16 and 1/2"-13 rod
Material: Steel
Function: Designed to hook on top chord of metal bar joist.
Hanger rod is threaded into product and secured with a wash-
er and nut.
Approvals: Underwriters Laboratories Listed in the USA (UL)
and Canada (cUL) for up to 4" (loomm) pipe with 3/8"-16 rod,
up to 6" (150mm) pipe with 1/2"-13 rod.
Finish: Plain. Contact B-Line for alternative finishes and
materials.
Order By: Part number, width and thickness of bar joist, and
finish.
C@"
LISTED
Rod Size For Pipe Size Design Load Approx. Wt./100
Part No. Size in. (mm) Lbs. (M) Lbs. (kg)
B-Line
by E:T-N
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
45
Pipe Hangers & Supports
Beam Clamps
Fig. 130 - Trus Joist Beam Clamp (B-Line Fig. B3052)
Size Range: 130-1
= TJI 35
130-2
= -
130-3
= TJI 25
130-4
= TJI 55 & 65
130-5
= TJI 75
130-6
= TJI 96
Material: Steel
Function: Designed for attachment to trus joist beams.
Use with B3210 Series eye rods.
Approvals: Sizes 1 - 6 are Underwriters Laboratories
Listed in the USA (UL) and Canada (cUL) list through
4" (loomm) pipe. All Fig. 130 Beam Clamps meet
requirements of Factory Mutual Engineering and NFPA 13,
through 4" (loomm) pipe.
Finish: Electro-Galvanized or Hot -Dip Galvanized
Order By: Part number and finish.
ce us w
LISTED
FM A H
Hardware
Included 1.r
(25.4)
(3.2)
III (50.8) 1
W. (19.0)
Material Thickness (9.5)
11 Gauge (3.0)
130-1
HardwarePart
3/8"-16
31/4"
(82.5)
11/2"
(38.1)
25/16"
(58.7)
pp11
65 (29.5)
130-2
3/8"-16
31/2"
(88.9)
13/4"
(44.4)
21/2"
(63.5)
70
(31.7)
130-3
3/8"-16
31/4"
(82.5)
11/2"
(38.1)
13/4"
(44.4)
58
(26.3)
130-4
3/8"-16
31/2"
(88.9)
11/2"
(38.1)
31/2"
(88.9)
83
(37.6)
130-5t
1/2"-13
35/8"
(92.1)
13/4"
(44.4)
31/2"
(88.9)
86
(39.0)
130-6t
1/2"-13
41/2"
1 (114.3)
1 21/2"
1 (63.5)
1 37/8"
1 (98.4)
1 101
1 (45.8)
'H' and Ware beam dimensions.
Maximum Recommended Load 500 Lbs. (2.22kN) Safety Factor of 5
t Larger bolts and I -rods are required for 5" (125mm) and 6" (150mm) pipe sizes
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
46
B-Line
by E:T■N
Pipe Hangers
Pipe hangers offered in this section are designed to support insulated or non -insulated pipe allowing for vertical
adjustment and limited movement in the piping system.
Materials
Carbon Steel, Malleable Iron and AISI Type 304 & 316 Stainless Steel are used in the manufacturing of pipe
hangers. Other materials are available.
Finishes
The standard finishes for mechanical supports are plain steel (oil coated) sometimes referred to as black,
Electro-Galvanized Zinc (ASTM B633 SC3), Pre -Galvanized (ASTM A653 G90), Hot -Dip Galvanized After Fabrication
(ASTM A123), Red Primer, Plastic Coating, DURA-GREEN'", DURA-COPPER'" and other special coatings are
available upon request.
Note: Due to the design of some products, (threads, connecting hardware, swivels, etc.) items may or may not
be uniformly coated with special finishes i.e. Hot -Dip Galvanized, DURA-GREEN, DURA-COPPER, PVC etc. In some
cases, the hanger itself may be coated, however, the hardware may be supplied Electro-Plated, DURA-COPPER
Painted or Stainless Steel. Consult B-Line Systems for availability.
Approvals (as noted)
Items in this section are Underwriters Laboratories Listed, Factory Mutual Approved, and comply with Federal
Specification WW-H-171 E & A-A-1192A or Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58.
Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development
(OSHPD)
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
by -Line by Ect•N 47 Pipe Hangers & Supports
Pipe Hangers
Fig.1 CBS - Clevis Pipe Spacer (Cooper B-Line B3100PS)
Size Range: Size 1 " (25mm) thru 20" (500mm) clevis hanger
Material: Steel
Function: Used as a spacer at a seismic brace location to
keep clevis hanger from collapsing during seismic event.
Approvals: Included in our Seismic Restraints Catalog
approved by the State of California Office of Statewide
Health Planning and Development (OSHPD). For additional
load, spacing and placement information relating to OSHPD
projects, please refer to the Seismic Restraint Systems
Guidelines.
Installation Note: Fig. 1 CBS fits easily over the cross bolt
and attaches by pinching tabs down.
Finish: Pre -Galvanized. Contact B-Line for alternative
finishes and materials.
Order By: Part number and finish.
1CBS-1
Pipe
1"
Size
(25)
Approx.00
3.2
(1.4)
ICBS-11/4
11/4"
(32)
4.1
(1.8)
1CBS-11/2
11/2"
(40)
4.8
(2.2)
1CBS-2
2"
(50)
9.4
(4.2)
ICBS-21/2
21/2"
(65)
11.4
(5.2)
1CBS-3
3"
(75)
13.9
(6.8)
ICBS-31/2
31/2"
(90)
16.0
(7.2)
1 CBS-4
4"
(100)
18.0
(8.1)
1CBS-5
5"
(125)
27.3
(12.4)
1CBS-6
6"
(150)
32.5
(14.7)
1CBS-8
8"
(200)
42.5
(19.2)
1CBS-10
10"
(250)
72.7
(32.9)
1CBS-12
12"
(300)
86.3
(39.1)
ICBS-14
14"
(350)
157.6
(71.5)
1CBS-16
16"
(400)
183.7
(83.3)
1CBS-18
18"
(450)
224.6
(101.9)
1CBS-20
20"
(500)
254.0
(115.2)
Component of State of
California OSHPD Approved
Seismic Restraints System
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
48
B-Line
by E:T■N
Pipe Hangers
B3100 - Standard Clevis Hanger (TOLGO Fig.1)
SLIDE-RITETM Clevis Hanger Features
Pipe will not `pinch' when installing.
15' swing in either direction allows pipe to easily
feed thru.
Engineered design aligns bolt holes for quicker
overhead installation.
'SLIDE-RITETM Clevis Hanger
design, as shown below, for
sizes 2, 21/2, 3, 4, 5 & 6.
Pat. No. 5,848,770
5,924,655
C VL us <FM
LISTED
Component of State of
California OSHPD Approved
Seismic Restraints System
B
Bottom of pipe to top of hanger.
C
Not Center of pipe to top of hanger.
D
Rod Take -Out
Center of pipe to bottom of
hangerrod.
E
Minimum thread length of
hangerrod
F
Adjustment
Top of cross bolt to bottom of hanger
rod nut inside the hanger.
r
Part i
B3100-1/2
NominalRod
1/2"
(15)
Size A
3/8"-16 3/8"-16
21/8"
B
(54.0)
13/4"
G
(44.4)
15/16"
1
(23.8)
B3100-3/4
3/4"
(20)
3/8"-16
3/8"-16
21/2"
(63.5)
2"
(50.8)
11/8"
(28.6)
B3100-1
1"
(25)
3/8"-16
3/8"-16
27/8"
(73.0)
21/4"
(57.1)
13/8"
(34.9)
B3100-11/4
11/4"
(32)
3/8"-16
3/8"-16
31/2"
(88.9)
211/16"
(68.2)
113/16"
(46.0)
B3100-11/2
11/2"
(40)
3/8"-16
3/8"-16
4"
(101.6)'
31/16"
(77.8)
21/4"
(57.1)
B3100-2 *
2"
(50)
3/8"-16
3/8"-16
41/2"
(114.3)
35/16"
(84.1)
21/2"
(63.5)
B3100-21/2 *
21/2"
(65)
1/2"-13
3/8"-16
53/8"
(136.5)
315/16"
(100.0)
31/16"
(77.8)
B3100-3 *
3"
(80)
1/2"-13
3/8"-16
61/2"
(165.1)
43/4"
(120.6)
315/16"
(100.0)
B3100-31/2
31/2"
(90)
1/2"-13
3/8"-16
71/4"
(184.1)
51/4"
(133.3)
41/16"
(103.2)
B3100-4 *
4"
(100)
5/8"-11
3/8"-16
73/4"
(196.8)
51/2"
(139.7)
51/2"
(139.7)
B3100-5 *
5"
(125)
5/8"-11
1/2"-13
83/4"
(222.2)
61/8"
(155.6)
6"
(152.4)
B3100-6 *
6"
(150)
3/4"-10
1/2"-13
105/16"
(261.9)
615/16"
(176.2)
7"
(177.8)
B3100-8
8"
(200)
3/4"-10
1/2"-13
123/4"
(323.8)
87/16"
(214.3)
71/8"
(181.0)
B3100-10
10"
(250)
7/8"-9
5/8"-11
151/8"
(384.2)
93/4"
(247.6)
83/8"
(212.7)
B3100-12
12"
(300)
7/8"-9
5/8"-11
171/2"
(444.5)
111/8"
(282.6)
911/16"
(246.1)
B3100-14
14"
(350)
1"-8
193/8"
(492.1)
123/8"
(314.3)
105/8"
(269.9)
B3100-16
16"
(400)
1 "-8
213/8"
(542.9)
133/8"
(339.7)
119/16"
(293.7)
B3100-18
18"
(450)
1 "-8
25"
(635.0)
16"
(406.4)
143/16"
(360.3)
B3100-20
20"
(500)
11/4"-7
283/4"
(730.2)
173/4"
(450.8)
165/8"
(422.3)
B3100-24
24"
(600)
11/4"-7
323/4"
(831.8)
193/4"
(501.6)
185/8"
(473.1)
B3100-30
30"
(750)
11/4"-7
3915/16"
(1014.4)
2415/16"
(633.4)
223/4"
(577.8)
B3100-36
36"
(900)
11/4"-7
46"
(1168.4)
28"
(711.2)
25"
(635.0)
B-Line
by E:T-N
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
49
Pipe Hangers & Supports
Pipe Hangers
B3100 - Standard Clevis Hanger (TOLCO Fig.1)
Size Range: 1/2" (15mm) to 36" (900mm)
Material: Steel
Component of State of
California OSHPD Approved
Seismic Restraints System
Function: Recommended for the suspension of non -insulated pipe or insulated pipe with a B3151 shield.
Note: When an oversized clevis is used, a pipe spacer should be placed over the cross bolt to assure that the
lower U-strap will not move in on the bolt. When attaching seismic bracing to the clevis hangers, a B3100PS
(cross bolt spacer) must be installed. See Seismic Restraints Approval Guidelines.
Order pipe sleeves Fig. 1CBS-(pipe size) separately.
Approvals: Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide
Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to
OSHPD projects, please refer to the B-Line/TOLCO Seismic Restraint Systems Guidelines. Underwriter's
Laboratories Listed in the USA (UL) and Canada (cUL) for sizes 3/4" (2omm) thru 12" (300mm). Factory Mutual
Engineering Approved (FM) for 3/4" (20mm) thru 12" (300mm) pipe. Conforms to Federal Specification WW-H-171 E &
A-A-1192A, Type 1 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 1. Also available to
accommodate rod schedule per per National Fire Protection Association (NFPA) Pamphlet 13.
Maximum Temperature: 650°F (343°C).
Standard Finish: Plain, Electro-Galvanized, DURA-GREEN"", or Hot -Dip Galvanized C& us <FM
also available in Stainless Steel LISTED
Order By: Part number and finish.
For AWWA - Ductile Iron Clevis Hangers, see 133102, page 51.
** Note: Do not use the dimensions shown in the B3100 chart for NFPA hanger sizes.
Contact B-Line for NFPA rod sizing on 1/2" (15mm) thru 12" (300mm) pipe.
Part numbers will be 1 NFPA-pipe size.
B3100-1/2
21/2" (63.5)
7/16" (11.1)
Design
730
Load
(3.25)
Approx.II
25
(11.3)
B3100-3/4
21/2"
(63.5)
1/2"
(12.7)
730
(3.25)
29
(13.1)
B3100-1
21/2"
(63.5)
5/8"
(15.9)
730
(3.25)
35
(15.9)
B3100-11/4
21/2"
(63.5)
7/8"
(22.2)
730
(3.25)
40
(18.1)
B3100-11/2
21/2"
(63.5)
13/16"
(30.2)
730
(3.25)
42
(19.0)
B3100-2 *
21/2"
(63.5)
15/8"
(41.3)
730
(3.25)
52
(23.6)
B3100-21/2 *
21/2"
(63.5)
2"
(50.8)
1350
(6.00)
90
(40.8)
B3100-3 *
21/2"
(63.5)
2"
(50.8)
1350
(6.00)
110
(49.9)
B3100-31/2
21/2"
(63.5)
2"
(50.8)
1350
(6.00)
142
(64.4)
B3100-4 *
21/2"
(63.5)
2"
(50.8)
1430
(6.36)
132
(59.9)
B3100-5 *
21/2"
(63.5)
2"
(50.8)
1430
(6.36)
215
(97.5)
B3100-6 *
3"
(76.2)
2"
(50.8)
1940
(8.63)
320
(145.1)
B3100-8
31/2"
(88.9)
25/16"
(58.7)
2000
(8.89)
485
(220.0)
B3100-10
31/2"
(88.9)
25/16"
(58.7)
3600
(16.01)
846
(383.7)
B3100-12
31/2"
(88.9)
25/8"
(66.7)
3800
(16.90)
1083
(491.2)
B3100-14
IP
4"
(101.6)
27/8"
(73.0)
4200
(18.68)
1432
(649.5)
B3100-16
4"
(101.6)
211/16"
(68.3)
4600
(20.46)
2200
(997.9)
B3100-18
41/2"
(114.3)
315/16"
(100.0)
4800
(21.35)
2500
(1134.0)
B3100-20
5"
(127.0)
53/8"
(136.5)
4800
(21.35)
4400
(1995.8)
B3100-24
5"
(127.0)
53/8"
(136.5)
4800
(21.35)
5000
(2268.0)
B3100-30
5"
(127.0)
61/4"
(158.7)
6000
(26.69)
6600
(2993.7)
B3100-36
5"
(127.0
57f16"
(138.1)
6000
(26.69)
8474
(3843.8)
SLIDE-RITETM Clevis Hanger design, as shown above, for sizes 2, 21h, 3, 4, 5 & 6.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
50
B-Line
by E:T■N
Pipe Hangers
B3102 - A.W.W.A. Clevis Hanger (TOLCO Fig. ci)
Size Range: 4" (100mm) to 24" (600mm)
Material: Steel
Function: Recommended for the suspension of
flanged or bell and spigot A.W.W.A. cast iron or
ductile iron pipe. The O.D. of the A.W.W.A. iron
pipe is shown in the data table.
Approvals: Conforms to Federal Specification
WW-H-171 E & A-A-1192A, Type 1 and
Manufacturers Standardization Society ANSI/MSS
SP-69 & SP-58, Type 1.
Standard Finish: Plain & Electro-Galvanized.
Contact B-Line for alternative finishes and
materials.
Order By: Part number and finish.
A
B
Bottom of pipe t0 top of hanger.
of C
Center of pipe to top of hanger.
D
Rod Take -Out
Center of pipe to bottom of
hangerrod.
E
Minimum thread length of
hangerrod
F
Adjustment
Top of cross bolt to bottom of hanger
rod nut inside the hanger.
B3102-4
Pipe O.D.
4.80 (121.9)
Rod Size
5/8"-11
B
85/16" (211.1)
513/16"
G
(147.6)
D
45/8" (117.5)
21/2"
E
(63.5)
2"
F
(50.8)
Design
1430
Load
(6.36)
Approx. Wt./1 00
203 (92.1)
B3102-6
6.90
(175.2)
3/4"-10
105/8"
(269.9)
71/16"
(179.4)
513/16"
(147.6)
3"
(76.2)
2"
(50.8)
1940
(8.63)
352
(159.6)
B3102-8
9.05
(229.9)
3/4"-10
131/4"
(336.5)
85/8"
(219.1)
73/16"
(182.5)
31/2"
(88.9)
21/8"
(54.0)
2000
(8.89)
532
(241.3)
B3102-10
11.10
(281.9)
7/8"-9
157/8"
(403.2)
101/4"
(260.3)
811/16"
(220.6)
31/2"
(88.9)
21/4"
(57.1)
3600
(16.01)
800
(362.9)
B3102-12
13.20
(335.3)
7/8"-9
18"
(457.2)
115/16"
(287.3)
93/4"
(247.6)
31/2"
(88.9)
21/4"
(57.1)
3800
(16.90)
1152
(522.5)
B3102-14
15.30
(388.6)
1 "-8
203/8"
(517.5)
125/8"
(320.7)
113/16"
(281.6)
4"
(101.6)
27/8"
(73.0)
4200
(18.68)
1449
(657.2)
B3102-16
17.40
(441.9)
1"-8
231/2"
(569.9)
1411/16"
(373.1)
127/8"
(327.0)
4"
(101.6)
33/8"
(85.7)
4600
(20.46)
2100
(952.6)
B3102-18
19.50
(495.3)
1 "-8
255/8"
(650.9)
153/4"
(400.0)
1315/16"
(354.0)
41/2"
(114.3)
33/8"
(85.7)
4800
(21.35)
2294
(1040.5)
B3102-20
21.60
(548.6)
11/4"-7
291/2"
(749.3)
189/16"
(471.5)
177/16"
(442.9)
5"
(127.0)
413/16"
(122.2)
4800
(21.35)
3887
(1763.1)
B3102-24
25.80
(655.3)
11/4"-7
33"
(838.2)
191/8"
(508.0)
20"
(485.8)
5"
(127.0)
51/4"
(133.3)
4800
(21.35)
4844
(2197.2)
B-Une
by FIT-N
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
51
Pipe Hangers & Supports
Pipe Hangers
B3108 - Extended Clevis Hanger (Tol-CO Fig.1A)
Size Range: 3/4" (20mm) thru 12" (300mm) pipe
Material: Steel
Function: Recommended for the suspension of insulated
pipe where the temperature does not require the use of
slides, guides, or rollers for movement.
Approvals: Conforms to Federal Specification WW-H-171 E
& A-A-1192A, Type 1 and Manufacturers Standardization
Society ANSI/MSS SP-69 & SP-58, Type 1.
Maximum Temperature: 650oF (3430C).
Order By: Part number and finish. For service
For Stainless Steel add SS to part number.
Standard Finish: Plain, Electro-Galvanized or Hot Dip
Galvanized
For service temperatures of 750°F (399°C) thru
1050°F (565°C) specify Type 304 Stainless Steel
A
(Rod Size)
Hanger Rod Not
Included
B3108-3/4
Nominal
3/4"
Pipe Size
(20)
Rod
3/8"-16
43/8"
(111.1)
313/16"
(96.8)
1
31/16" (77.8)
B3108-1
1"
(25)
3/8"-16
43/4"
(120.6)
41/16"
(103.2)
31/4"
(82.5)
B3108-11/4
11/4"
(32)
3/8"-16
53/8"
(136.5)
41/2"
(114.3)
35/16"
(84.1)
B3108-11/2
11/2"
(40)
3/8"-16
67/8"
(174.6)
515/16"
(150.8)
51/8"
(130.2)
B3108-2
2"
(50)
3/8"-16
813/16"
(223.8)
75/8"
(193.7)
67/8"
(174.6)
B3108-21/2
21/2"
(65)
1/2"-13
10"
(254.0)
81/2"
(215.9)
79/16"
(192.1)
B3108-3
3"
(80)
1/2"-13
105/8"
(269.9)
813/16"
(223.8)
77/8"
(200.0)
B3108-4
4"
(100)
5/8"-11
1113/16
(300.0)
91/2"
(241.3)
83/8"
(212.7)
B3108-5
5"
(125)
5/8"-11
131/8"
(333.4)
105/16"
(261.9)
91/8"
(231.8)
B3108-6
6"
(150)
3/4"-10
143/8"
(365.1)
11"
(279.5)
911/16"
(246.0)
B3108-8
8"
(200)
3/4"-10
163/4"
(425.4)
123/8"
(314.3)
111/8"
(282.6)
B3108-10
10"
(250)
7/8"-9
191/4"
(488.9)
1313/16"
(350.8)
125/16"
(312.7)
B3108-12
12"
(300)
1 7/8"-9
1 215/8"
(549.3)
153/16"
(385.8)
135/8"
(346.1)
B
Bottom of pipe to top of hanger.
C
Center of pipe to top of hanger.
D
Rod Take -Out
Center of pipe to bottom of
hangerrod.
E
Minimum thread length of
hangerrod.
F
Adjustment
Top of cross bolt to bottom of
hanger rod nut inside the hanger.
H
Maximum insulation thickness.
Part i
B3108-3/4
21/2" (63.5)
1/2"
(12.7)
2" (50.8)
730 (3.25)
45 (20.4)
B3108-1
21/2"
(63.5)
5/8"
(15.9)
2"
(50.8)
730
(3.25)
49
(22.2)
B3108-11/4
21/2"
(63.5)
7/8"
(22.2)
2"
(50.8)
730
(3.25)
55
(24.9)
B3108-11/2
21/2"
(63.5)
13/16"
(30.2)
2"
(50.8)
730
(3.25)
67
(30.4)
B3108-2
21/2"
(63.5)
15/8"
(41.3)
4"
(101.6)
730
(3.25)
83
(37.6)
B3108-21/2
21/2"
(63.5)
2"
(50.8)
4"
(101.6)
1350
(6.00)
177
(80.3)
B3108-3
21/2"
(63.5)
2"
(50.8)
4"
(101.6)
1350
(6.00)
191
(86.6)
B3108-4
21/2"
(63.5)
2"
(50.8)
4"
(101.6)
1430
(6.36)
237
(107.5)
B3108-5
21/2"
(63.5)
2"
(50.8)
4"
(101.6)
1430
(6.36)
302
(137.0)
B3108-6
3"
(76.2)
2"
(50.8)
4"
(101.6)
1940
(8.63)
397
(180.1)
B3108-8
31/2"
(88.9)
25/16"
(58.7)
4"
(101.6)
2000
(8.89)
582
(264.0)
B3108-10
31/2"
(88.9)
25/16"
(58.7)
4"
(101.6)
3600
(16.01)
968
(439.1)
B3108-12 J
31/2"
(88.9)
25/8"
(66.7)
4"
(101.6)
3800
(16.90)
1221
(553.8)
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
52
B-Line
by E:J-N
Pipe Hangers
B3100C - Standard Clevis Hanger - Plastic Coated (TOLCo Fig.1 PVC)
B310OF - Standard Clevis Hanger - Felt Lined for Copper Tubing (TOLCO F19.1 F)
Size Range: 1/2" (15mm) to 8" (200mm) pipe
Material: Steel
Insulation Material: 3/16" (4.8mm) Felt
Service: The B3100F is designed for the suspension of
copper tube so as to prevent electrolysis between tubing
and hanger. The B3100C is designed for steel or other
pipe types of the same O.D. Both B3100F and B3100C
act to reduce noise and vibration in pipe or tubing
systems.
Approvals: Underwriter's Laboratories Listed in the USA
(UL) and Canada (cUL).
Maximum Temperature: 650OF (343°C).
Standard Finish: Plain, Electro-Galvanized, or Hot -Dip
Galvanized. Contact B-Line for alternative finishes and
materials.
Order By: Part number and finish.
C@ W.
LISTED
B
A
Bottom of pipe to top of hanger.
(Rod Size)
C
Hanger Rod Not
Center of pipe to top of hanger.
Included
0
Rod Take -Out
Center of pipe to bottom of
hanger rod.
E
Minimum thread length of
hangerrod
ii
F
Adjustment
C
Top of cross bolt to bottom of hanger
rod nut inside the hanger.
Part ' B3100-1/2
Pipe
1/2"
Size
(15)
Rod
3/8"-16
21/8" (54.0)
111/16"
(42.9)
15/16"
(23.8)
B3100-3/4
3/4"
(20)
3/8"-16
27/16"
(61.9)
17/8"
(47.6)
11/8"
(28.6)
B3100-1
1"
(25)
3/8"-16
213/16"
(71.4)
21/8"
(54.0)
13/8"
(34.9)
B3100-11/4
11/4"
(32)
3/8"-16
37/16"
(87.3)
29/16"
(65.1)
113/16"
(46.0)
B3100-11/2
11/2"
(40)
3/8"-16
4"
(101.6)'
3"
(76.2)
21/4"
(57.1)
B3100-2
2"
(50)
3/8"-16
41/2"
(114.3)
31/4"
(82.5)
21/2"
(63.5)
B3100-21/2
21/2
(65)
1/2"-13
59/16"
(141.3)
4"
(101.6)
31/16"
(77.8)
B3100-3
3"
(80)
1/2"-13
63/4"
(171.4)
47/8"
(123.8)
315/16"
(100.0)
B3100-31/2
31/2"
(90)
1/2"-13
7"
(177.8)
5"
(127.0)
41/16"
(103.2)
B3100-4
4"
(100)
5/8"-11
713/16"
(198.4)
51/2"
(139.7)
43/8"
(111.1)
B3100-5
5"
(125)
5/8"-11
91/16"
(230.2)
61/8"
(155.6)
5"
(127.0)
B3100-6
6"
(150)
3/4"-10
107/16"
(265.1)
615/16
(176.2)
511/16"
(144.5)
B3100-8
8"
(200)
3/4"-10
123/4"
(323.8)
1 83/8"
(212.7)
1 71/8"
(181.0)
B3100-1/2
E
21/2" (63.5)
Adjustment
�/16"
F
(11.1)
Design
730
Load
(3.25)
Approx.tt
25
(11.3)
B3100-3/4
21/2"
(63.5)
1/2"
(12.7)
730
(3.25)
29
(13.1)
B3100-1
21/2"
(63.5)
5/8"
(15.9)
730
(3.25)
35
(15.9)
B3100-11/4
21/2"
(63.5)
7/8"
(22.2)
730
(3.25)
40
(18.1)
B3100-11/2
21/2"
(63.5)
13/16"
(30.2)
730
(3.25)
42
(19.0)
B3100-2
21/2"
(63.5)
15/8"
(41.3)
730
(3.25)
52
(23.6)
B3100-21/2
21/2"
(63.5)
2"
(50.8)
1350
(6.00)
90
(40.8)
B3100-3
21/2"
(63.5)
2"
(50.8)
1350
(6.00)
110
(49.9)
B3100-31/2
21/2"
(63.5)
2"
(50.8)
1350
(6.00)
142
(64.4)
B3100-4
21/2"
(63.5)
2"
(50.8)
1430
(6.36)
132
(59.9)
B3100-5
21/2"
(63.5)
2"
(50.8)
1430
(6.36)
215
(97.5)
B3100-6
3"
(76.2)
2"
(50.8)
1940
(8.63)
320
(145.1)
B3100-8
31/2"
(88.9)
25/16"
(58.7)
2000
(8.89)
485
(220.0)
B3100C
B3100F
B-Erne
by FIT-N
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
53
Pipe Hangers & Supports
Pipe Hangers
B3690 - J-Hanger for Pipe or Conduit (ToLCo Fig. 3)
B3690F - Felt Lined J-Hanger for Copper Tubing (ToLCo Fig. 3F)
B3690C - PVC Coated J-Hanger for Pipe or Conduit (Toi-Co Fig. 3PVC)
Size Range: 1/2" (15mm) to 10" (250mm) pipe size
Material: Steel
Function: Recommended for the suspension of
non -insulated pipe, or insulated pipe with B3151 shield.
Side hole allows for wall mounting.
B3690F and B3690C are designed to reduce noise and
vibration and/or prevent electrolysis between pipe and
hanger.
Approvals: Conforms Manufacturers Standardization
Society ANSI/MSS SP-69 & SP-58, Type 5.
Standard Finish: Electro-Plated. Contact B-Line
for alternative finishes and materials.
Order By: Part number and finish.
B369OF
A
(Rod Size) i
Hanger Rod Not
Included
B3690C
B
Center of pipe to top of hanger.
F
Rod Take -Out
Center of pipe to bottom of
hanger rod.
B3690-1/2
Pipe
1/2"
O.D.
(15)
Rod Size
3/8"-16
B
25/8" (66.7)
13/4"
C
(44.4)
D
7/16"
(11.1)
11/2"
E
(38.1)
115/16"
F
(49.2)
Design
400
Load
(1.78)
Approx. Wt./100
18 (8.1)
B3690-3/4
3/4"
(20)
3/8"-16
27/8"
(73.0)
17/8"
(47.6)
7/16"
(11.1)
111/16"
(42.9)
21/8"
(54.0)
400
(1.78)
21
(9.5)
B3690-1
1"
(25)
3/8"-16
215/16"
(74.6)
115/16"
(49.2)
7/16"
(11.1)
113/16"
(46.0)
25/16"
(58.7)
400
(1.78)
22
(10.0)
B3690-11/4
11/4"
(32)
3/8"-16
31/4"
(82.5)
2"
(50.8)
7/16"
(11.1)
21/16"
(52.4)
25/8"
(66.7)
400
(1.78)
25
(11.3)
B3690-11/2
11/2"
(40)
3/8"-16
39/16"
(90.5)
23/16"
(55.6)
7/16"
(11.1)
27/16"
(61.9)
27/8"
(73.0)
400
(1.78)
27
(12.2)
B3690-2
2"
(50)
3/8"-16
311/16"
(93.7)
21/8"
(54.0)
7/16"
(11.1)
29/16"
(65.1)
31/16"
(77.8)
400
(1.78)
29
(13.1)
B3690-21/2
21/2"
(65)
1/2"-13
47/16"
(112.7)
27/16"
(61.9)
9/16"
(14.3)
33/16"
(81.0)
35/8"
(92.1)
500
(2.22)
64
(29.0)
B3690-3
3"
(80)
1/2"-13
413/16"
(122.2)
29/16"
(65.1)
9/16"
(14.3)
31/2"
(88.9)
41/16"
(103.2)
500
(2.22)
72
(32.6)
B3690-31/2
31/2"
(90)
1/2"-13
51/8"
(130.2)
25/8"
(66.7)
9/16"
(14.3)
33/4"
(95.2)
43/8"
(111.1)
500
(2.22)
84
(38.1)
B3690-4
4"
(100)
5/8"-11
61/8"
(155.6)
33/16"
(81.0)
9/16"
(14.3)
45/8"
(117.5)
53/16"
(131.8)
550
(2.44)
138
(62.6)
B3690-5
5"
(125)
5/8"-11
63/4"
(171.4)
31/4"
(82.5)
9/16"
(14.3)
51/16"
(128.6)
53/4"
(146.0)
550
(2.44)
162
(73.5)
B3690-6
6"
(150)
3/4"-10
73/4"
(196.8)
39/16"
(90.5)
9/16"
(14.3)
513/16"
(147.6)
65/8"
(168.3)
600
(2.67)
249
(112.9)
B3690-8
8"
(200)
7/8"-9
93/16"
(233.4)
315/16"
(100.0)
9/16"
(14.3)
615/16"
(176.2)
8"
(203.3)
760
(3.38)
291
(132.0)
B3690-10
10"
(250)
7/8"-9
103/4"
(273.0)
37/8"
(98.4)
9/16"
(14.3)
75/8"
(193.7)
91/8
(231.8)
760
(3.38)
315
(142.9)
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
54
B-Line
by E:T■N
Pipe Hangers
B3109 - Flat Top Clevis Hanger
Size Range: 2" (50mm) to 8" (200mm) pipe size
Material: Steel
Function: Recommended for suspending non -
insulated, stationary pipe where space is limited.
Approvals: Complies with Manufacturers
Standardization Society ANSI/MSS SP-69 & SP-58
Type 1.
Standard Finish: Plain or Electro-Galvanized
Order By: Part number and finish.
A
(Rod Size)
Hanger Rod Not
Included
Part
B3109-2 '
Rod Size
3/8"-16
B
313/16"
B3109-21/2
21/2"
(65)
1/2"-13
45/8"
(117.5)
B3109-3
3"
(80)
1/2"-13
55/16"
(134.9)
B3109-31/2
31/2"
(90)
1/2"-13
513/16"
(147.6)
B3109-4
4"
(100)
5/8"-11
61/2"
(165.1)
B3109-5
5"
(125)
5/8"-11
713/16"
(198.4)
B3109-6
6"
(150)
3/4"-10
97/16"
(230.2)
B3109-8
8"
(200)
3/4"-10
113/8"
(288.9)
63109-2
25/8"
G
(66.7)
Rod Take
1 7/8"
-Out D
(47.6)
Design Load
300 (1.33)
Approx.
52
Wt./100
(23.6)
B3109-21/2
33/16"
(81.0)
23/16"
(55.6)
500
(2.22)
116
(52.6)
B3109-3
39/16"
(90.5)
25/8"
(66.7)
500
(2.22)
133
(60.3)
B3109-31/2
313/16"
(96.8)
27/8"
(73.0)
500
(2.22)
145
(65.8)
B3109-4
41/4"
(107.9)
31A"
(79.4)
700
(3.11)
180
(81.6)
B3109-5
5"
(127.0)
37/8"
(98.4)
700
(3.11)
248
(112.5)
B3109-6
511/16"
(144.5)
47/16"
(112.7)
900
(4.00)
332
(150.6)
B3109-8
7"
(177.8)
513/16"
(147.6)
1000
(4.45)
513
(232.7)
B
Bottom of pipe
to top of hanger.
C
Center of pipe
to top of hanger.
D
Rod Take -Out
Center of pipe to
bottom of hanger rod.
B-Une
by FIT-N
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
55
Pipe Hangers & Supports
Pipe Hangers
B3106 - Vee Bottom Clevis Hanger JOLCo Fig.1v)
Size Range: 112" (15mm) to 4" (loomm) pipe
Material: Steel
Function: Recommended for the suspension of
flexible plastic pipe. Use with B3106V support
trough for plastic pipe.
Approvals: Complies with Manufacturers
Standardization Society ANSI/MSS SP-69 & SP-58
Type 1.
Standard Finish: Plain & Elect ro-Galvan ized.
Contact B-Line for alternative finishes and materials.
Order By: Part number and finish.
B3106V - Plastic Pipe Support Channel JOLCO Fig. 1VT)
Size Range: 1/2" (15mm) to 4" (100mm) pipe
Material: Steel
Function: Designed for use with B3106 as a T x
Steel
support for plastic or other flexible pipe systems.
Standard Finish: Pre -Galvanized. Contact
B-Line for alternative finishes and
materials.
Order By: Part number and finish
L
Size
B
A
(Rod Size)
Hanger Rod Not
B
Overall Height
C
Center of pipe to top of hanger.
D
Rod Take -Out
Center of pipe to bottom of hanger rod.
E
Minimum thread length of hanger rod.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
56
B-Line
by Ect•N
Pipe Hangers
B3104 - Light -Duty Clevis Hanger
B3104F - Light -Duty Clevis Hanger - Felt Lined
B3104C - Light -Duty Clevis Hanger - PVC Coated
Size Range: 1/2" (15mm) to 4" (100mm) pipe
Material: Steel
Function: Recommended for the suspension of light
stationary pipe allowing for vertical adjustment.
Approvals: Underwriter's Laboratories Listed in the USA (UL)
and Canada (cUL) for sizes 3/4" (20mm) thru 4" (1o0mm).
Conforms to Federal Specification WW-H-171 E & A-A-1192A,
Type 12 and Manufacturers Standardization Society
ANSI/MSS SP-69 & SP-58, Type 1.
Standard Finish: Plain, Electro-Galvanized,
or DURA-GREENT"
Order By: Part number and finish.
A
`Slide-RiteTM Clevis Hanger
design for sizes 2, 3 & 4.
Pat. No. 5,848,770
5,924,655
B3104-1/2
Pipe
1/2"
Size
(15)
Rod
3/8"-16
115/16" (49.2)
11/2" (38.1)
B3104-3/4
3/4"
(20)
3/8"-16
25/16"
(58.7)
13/4"
(44.4)
B3104-1
1 "
(25)
3/8"-16
23/4"
(69.8)
21/16"
(52.4)
B3104-11/4
11/4"
(32)
3/8"-16
35/16"
(84.1)
27/16"
(61.9)
B3104-11/2
11/2"
(40)
3/8"-16
35/8"
(92.1)
25/8"
(66.7)
B3104-2 *
2"
(50)
3/8"-16
413/16"
(122.2)
35/8"
(92.1)
B3104-21/2
21/2"
(65)
1/2"-13
513/16"
(147.6)
45/16"
(109.5)
B3104-3 *
3"
(80)
1/2"-13
67/16"
(163.5)
45/8"
(117.5)
B3104-31/2
31/2"
(90)
1/2"-13
615/16"
(176.2)
415/16"
(125.4)
B3104-4 *
4"
(100)
1/2"-13
73/4"
(196.8)
51/2"
(139.7)
Jot
C@01
LISTED
B
Bottom of pipe to top of hanger.
C
Center of pipe to top of hanger.
D
Rod Take -Out
Center of pipe to bottom of
hangerrod.
E
Minimum thread length of
hangerrod.
F
Adjustment
Top of cross bolt to bottom of hanger rod
nut inside the hanger.
B3104-1/2
•rrLoad
13/16" (20.6)
21/2"
(63.5)
7/16"
(11.1)
150
(.67)
Approx. Wt./100
13 (5.9)
B3104-3/4
1"
(25.4)
21/2"
(63.5)
7/16"
(11.1)
250
(1.11)
22
(10.0)
B3104-1
13/8"
(34.9)
21/2"
(63.5)
9/16"
(14.3)
250
(1.11)
24
(10.9)
B3104-11/4
13/4"
(44.4)
21/2"
(63.5)
13/16"
(20.6)
250
(1.11)
29
(13.1)
B3104-11/2
2"
(50.8)
21/2"
(63.5)
1"
(25.4)
250
(1.11)
30
(13.6)
B3104-2 *
215/16"
(74.6)
21/2"
(63.5)
13/4"
(44.4)
250
(1.11)
35
(15.9)
B3104-21/2
37/16"
(87.3)
21/2"
(63.5)
2"
(50.8)
350
(1.55)
82
(37.2)
B3104-3 *
33/4"
(95.2)
21/2"
(63.5)
2"
(50.8)
350
(1.55)
91
(41.3)
B3104-31/2
4"
(101.6)
21/2"
(63.5)
2"
(50.8)
350
(1.55)
98
(44.4)
B3104-4 *
49/16"
(115.9)
21/2"
(63.5)
23/16"
(55.6)
400
(1.78)
132
(59.9)
B3104C
B3104F
B-Une
by E:T-IN
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
57
Pipe Hangers & Supports
Pipe Hangers
B3104CT - Clevis Hanger (TOLCO Fig. 81)
B3104CTC - Clevis Hanger - PVC Coated (TOLCO Fig. 811PVC)
Size Range: 1/2" (15mm) to 6" (150mm) copper tubing
Material: Steel
Function: Recommended for the suspension of
non- insulated stationary copper tubing lines.
Available with plastic coating to provide additional
separation between tubing and hanger.
Approvals: Conforms to Federal Specification
WW-H-171 E & A-A-1192A, Type 12 and
Manufacturers Standardization Society
ANSI/MSS SP-69 & SP-58, Type 1. I
Standard Finish: DURA-COPPERTM
Order By: Part number and finish.
B3104CTC
A
B
Bottom of pipe to top of hanger.
c
Center of pipe to top of hanger.
D
Rod Take -Out
Not Center of pipe to bottom
of hanger rod.
E
Minimum thread length
of hanger rod.
F
Adjustment
Top of cross bolt to bottom of
hanger rod nut inside the hanger.
B3104CT
B3104CT-1/2
Tubing Size
1/2" (15)
Rod Size
3/811-16
21/4"
B
(57.1)
115/16"
C
(49.2)
Rod Take -Out r
11/8" (28.6)
B3104CT-3/4
3/4"
(20)
3/8"-16
115/16"
(49.2)
11/2"
(38.1)
11/8"
(28.6)
B3104CT-1
ill
(25)
3/8"-16
25/16"
(58.7)
13/4"
(44.4)
15/16"
(33.3)
B3104CT-1 1/4
11/4"
(32)
3/8"-16
23/4"
(69.8)
21/16"
(52.4)
19/16"
(39.7)
B3104CT-11/2
11/2"
(40)
3/8"-16
35/16"
(84.1)
27/16"
(61.9)
21/16"
(52.4)
B3104CT-2
2"
(50)
3/8"-16
41/2"
(114.3)
37/16"
(87.3)
33/8"
(85.7)
B3104CT-21/2
21/2"
(65)
1/2"-13
511/16"
(144.5)
41/2"
(114.3)
315/16"
(100.0)
B3104CT-3
3"
(80)
1/2"-13
53/16"
(131.8)
35/8"
(92.1)
4"
(101.6)
B3104CT-31/2
31/2"
(90)
1/2"-13
61/2"
(165.1)
49/16"
(115.9)
41/8"
(104.8)
B3104CT-4
4"
(100)
1/2"-13
73/8"
(187.3)
35/16"
(134.9)
43/8"
(111.1)
B3104CT-5
5"
(125)
1/2"-13
9"
(228.6)
67/16"
(163.5)
53/4"
(146.0)
B3104CT-6
6"
(150)
5/8"-11
105/16"
(261.9)
71/4"
(184.1)
61/2"
(165.1)
B3104CT-1/2
21/2"
E
(63.5)
Adjustment F
3/8" (9.5)
Design
150
Load
(.67)
Approx.
12
Wt./100
(5.4)
B3104CT-3/4
21/2"
(63.5)
7/16"
(11.1)
250
(1.11)
12
(5.4)
B3104CT-1
21/2"
(63.5)
9/16"
(14.3)
250
(1.11)
22
(10.0)
B3104CT-11/4
21/2"
(63.5)
9/16"
(14.3)
250
(1.11)
24
(10.9)
B3104CT-11/2
21/2"
(63.5)
15/16"
(23.8)
250
(1.11)
30
(13.6)
B3104CT-2
21/2"
(63.5)
13/4"
(44.4)
250
(1.11)
35
(15.9)
B3104CT-21/2
21/2"
(63.5)
21/8"
(54.0)
350
(1.55)
80
(36.3)
B3104CT-3
21/2"
(63.5)
21/16"
(52.4)
350
(1.55)
88
(39.9)
B3104CT-31/2
21/2"
(63.5)
21/8"
(54.0)
350
(1.55)
94
(42.6)
B3104CT-4
21/2"
(63.5)
21/8"
(54.0)
400
(1.78)
116
(52.6)
B3104CT-5
21/2"
(63.5)
21/2"
(63.5)
550
(2.44)
208
(94.3)
B3104CT-6
21le
(63.5)
3"
(76.2)
550
(2.44)
247
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
58
B-Line
by E:T■N
Pipe Hangers
Fig. 2 - Adjustable Band Hanger (B-Line B3170) ce us A�
Fig. 2F - Adjustable Band Hanger Felt Lined for Copper Tubing (B-Line 133170F) LISTED
Size Range:
Fig. 2 - 21/2" (65mm) thru 6" (150mm) pipe
Fig. 2F - 21/2" (65mm) thru 6" (150mm) pipe
Material: Pre -Galvanized Steel
Function: Recommended for the suspension of non -
insulated pipe or insulated pipe with B3151 shield.
Fig. 2NFPA accomodates the reduced rod schedule of
the National Fire Pretection Association Pamphlet 13.
Approvals: Factory Mutual Engineering Approved.
Underwriters Laboratories Listed. Conforms to Federal
Specification WW-H-171 E & A-A-1192A Type 10 and
Manufacturers Standardization Society ANSI/MSS
SP-69 & SP-58, Type 10.
Standard Finish: Pre -Galvanized
Note: Available in Stainless Steel material.
Order By: Part number and finish.
Fig. 2
Fig. 2
Fig. 2F
(OTOLC❑
1�
Nominal
2-21/2
Pipe
21/2"
Size
(65)
Rod Size
1/2"-13 *
B
53/4"
(146.0)
41/4"
C
(107.9)
D
15/8"
(41.3)
Max. Rec.
600
Load
(2.67)
App rox
41
Wt./1 00
(18.6)
2-3
3"
(75)
1/2"-13 *
6"
(152.4)
41/8"
(104.8)
11/4"
(31.7)
600
(2.67)
45
(20.4)
2-31/2
31/2"
(90)
1/2"-13 *
73/8"
(187.3)
51/4"
(133.3)
21/8"
(54.0)
600
(2.67)
52
(23.6)
2-4
4"
(100)
5/8"-11 *
73/8"
(187.3)
5"
(127.0)
15/8"
(41.3)
1000
(4.45)
59
(27.6)
2-5
5"
(125)
5/8"-11 **
9"
(228.6)
61/8"
(155.6)
21/4"
(57.1)
1250
(5.56)
97
(44.0)
2-6
6"
(150)
3/4"-10 **
93/8"
(238.1)
61/2"
(165.1)
17/8"
(47.6)
1250
(5.56)
139
(63.0)
Fig. 2F
Nominal
2F-21/2
Pipe
21/2"
Size
(65)
Rod Size
1/2"-13 *
53/4"
B
(146.0)
41/4"
C
(107.9)
D
15/8
(41.3)
Max. Rec.
600
Load
(2.67)
Approx
41
Wt./1 00
(18.6)
2F-3
3"
(75)
1/2"-13 *
6"
(152.4)
41/8"
(104.8)
11/4"
(31.7)
600
(2.67)
45
(20.4)
2F-31/2
31/2"
(90)
1/2"-13 *
73/8"
(187.3)
51/4"
(133.3)
21/8"
(54.0)
600
(2.67)
52
(23.6)
2F-4
4"
(100)
5/8"-11 *
73/8"
(187.3)
5"
(127.0)
15/8"
(41.3)
1000
(4.45)
59
(27.6)
2F-5
5"
(125)
5/8"-11 **
9"
(228.6)
61/8"
(155.6)
21/4"
(57.1)
1250
(5.56)
97
(44.0)
2F-6
6"
(150)
3/41, -10 **
93/8"
(238.1)
61/2"
(165.1)
17/8"
(47.6)
1250
(5.56)
139
(63.0)
* 3/8 nut is used when requested. ** 1/2 nut is used when requested.
B-Line
by FffoN
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
59
Pipe Hangers & Supports
Pipe Hangers
B317OCT - Adjustable Swivel Hanger for Copper Tubing (ToLCo Fig. 202)
B317OCTC - Adjustable Swivel Hanger for Copper Tubing - Plastic Coated
Size Range: 1/2" (15mm) thru 6" (150mm) copper tubing
Material: Steel
Function: Recommended for the suspension of
B
copper tubing, allowing for vertical adjustment.
Center of pipe to top of
(Available with plastic coating to provide additional
knurled hanger rod nut.
separation between tubing and hanger.)
C
Rod Take -Out
Approvals: Conforms to Federal Specification
Center of pipe to bottom
WW-H-171 E & A-A-1192A, Type 10 and Manufacturers
of hanger rod.
Standardization Society ANSI/MSS SP-69 & SP-58,
Type 10.
Top of pipe to bottom of
hanger rod nut.
Standard Finish: DURA-COPPERT"'
Order By: Part number and finish.
Part No.
B317OCT-1/2
Nominal
• ,.
1/2" (15)
Rod Size
3/8"-16
B
21/16" (52.4)
11/8"
G
(28.6)
31/32
i
(24.6)
B317OCT-3/4
3/4"
(20)
3/8"-16
25/16"
(58.7)
15/16"
(33.3)
11/32"
(26.2)
B317OCT-1
1"
(25)
3/8"-16
21/2"
(63.5)
19/16"
(39.7)
15/32"
(29.3)
B317OCT-11/4
11/4"
(32)
3/8"-16
21/2"
(63.5)
19/16"
(39.7)
1"
(25.4)
B317OCT-11/2
11/2"
(40)
3/8"-16
215/16"
(74.6)
2"
(50.8)
15/16"
(33.3)
B317OCT-2
2"
(50)
3/8"-16
31/8"
(79.4)
21/8"
(54.0)
13/16"
(30.2)
B317OCT-21/2
21/2"
(65)
1/2"-13
41/16"
(103.2)
29/16"
(65.1)
13/8"
(34.9)
B317OCT-3
3"
(75)
1/2"-13
315/16"
(100.0)
33/4"
(95.2)
11/4"
(31.7)
B317OCT-31/2
31/2"
(90)
1/2"-13
47/16"
(112.7)
31/4"
(82.5)
11/2"
(38.1)
B317OCT-4
4"
(100)
1/2"-13
411/16"
(119.1)
39/16"
(89.6)
19/16"
(39.7)
B317OCT-5
5"
(125)
1/2"-13
515/16"
(150.8)
45/16"
(109.5)
125/32"
(45.2)
B317OCT-6
1 6"
(150)
1/2"-13
611/16"
(169.9)
53/16"
(131.8)
21/8"
(54.0)
FM
B317OCT-1/2
Max. Rec.
180
Load
(0.80)
Approx.
8
Wt./100
(6.6)
B317OCT-3/4
180
(0.80)
10
(4.5)
B317OCT-1
180
(0.80)
10
(4.5)
B317OCT-11/4
180
(0.80)
12
(5.4)
B317OCT-11/2
180
(0.80)
12
(5.4)
B317OCT-2
180
(0.80)
12
(5.4)
B317OCT-21/2
200
(0.89)
31
(24.0)
B317OCT-3
250
(1.11)
33
(14.9)
B317OCT-31/2
300
(1.33)
39
(17.2)
B317OCT-4
360
(1.60)
40
(18.1)
B317OCT-5
480
(2.13)
95
(43.1)
B317OCT-6
630
(2.80)
118
(53.5)
B317OCT
A
(Rod Size)
Rod Not
uded
B317OCTC
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
60
B-Line
by E:T■N
Pipe Hangers
Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line B317ONF)
Fig. 20OF - "Trimline" Adjustable Band Hanger with Felt Lining for Copper Tubing (B-Line B317ONFF)
Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line B317ONFc)
Size Range:
Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe ®TOLCO- C@ Its FM
Material: Steel, Pre -Galvanized to G90 specifications LISTED aP•.o�
Function: For fire sprinkler and other general piping purposes. Knurled
swivel nut design permits hanger adjustment after installation.
Features:
• (1/2" (15mm) thru 2" (5omm)) Flared edges ease installation for all pipe
types and protect CPVC plastic pipe from abrasion. Captured design
keeps adjusting nut from separating with hanger. Hanger is easily
installed around pipe.
• (21/2" (65mm) thru 8" (2oomm)) Spring tension on nut holds it securely in
hanger before installation. Adjusting nut is easily removed. I' ®/ „ a\\\ B
Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (2oomm))
in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and
Factory Mutual Engineering Approved (3/4" (20mm) thru 8" (200mm)). "
Conforms to Federal Specifications WW-H-171 E & A-A-1192A, Type 10
and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Fig. 200-1/2 to 200-2 Fig. 200-21/2 to 200-8
Type 10.
Maximum Temperature: 650OF (343°C)
Finish: Pre -Galvanized. Stainless Steel
materials will be supplied with (2) hex nuts
in place of a knurl nut. map
Order By: Part number and pipe size
** Note: For metric hanger rod sizes add the
VOW --
metric rod size to the figure number.
Example: 200M8-11/2 or 200M10-11/2 Fig. 200
Fig. 200C Fig. 20OF
200-1/2
Pipe
1/2"
Size
(15)
Rod
3/8"-16
Size
M8 or M10
A
31/8" (79.4)
25/8"
B
(66.7)
Max. Rec. Load
400 (1.78)
Approx.
11
Wt./1 00
(5.0)
200-3/4
3/4"
(20)
3/8"-16
M8 or M10
31/8"
(79.4)
21/2"
(63.5)
400
(1.78)
11
(5.0)
200-1
1"
(25)
3/8"-16
M8 or M10
33/8"
(85.7)
25/8"
(66.7)
400
(1.78)
12
(5.5)
200-11/4
11/4"
(32)
3/8"-16
M8 or M10
33/4"
(94.0)
27/8"
(73.0)
400
(1.78)
13
(5.9)
200-11/2
11/2"
(40)
3/8"-16
M8 or M10
37/8"
(98.4)
27/8"
(73.0)
400
(1.78)
14
(6.4)
200-2
2"
(50)
3/8"-16
M8 or M10
41/2"
(114.3)
3"
(76.3)
400
(1.78)
15
(6.9)
200-21/2
21/2"
(65)
3/8"-16
M10
55/8"
(142.9)
41/8"
(104.7)
600
(2.67)
27
(12.3)
200-3
3"
(75)
3/8"-16
M10
57/8"
(149.1)
4"
(101.6)
600
(2.67)
29
(13.3)
200-31/2
31/2"
(90)
3/8"-16
M10
73/8"
(187.3)
51/4"
(133.3)
600
(2.67)
34
(15.6)
200-4
4"
(100)
3/8"-16
M10
73/8"
(187.3)
5"
(127.0)
1000
(4.45)
35
(16.0)
200-5
5"
(125)
1/2"-13
M12
91/8"
(231.8)
61/4"
(158.7)
1250
(5.56)
66
(30.2)
200-6
6"
(150)
1/2"13
M12
101/8"
(257.2)
63/4"
(171.4)
1250
(5.56)
73
(33.4)
200-8
8"
1 (200)
1 1/2"-13
M12
131/8"
1 (333.4)
83/4"
(222.2)
1250
(5.56)
136
(62.3)
B-Line
by FffoN
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
61
Pipe Hangers & Supports
Pipe Hangers
Fig. 200H - Heavy Duty Band Hanger (For Trapeze)
Size Range: 2" (50mm) thru 4" (loomm) trapeze pipe size.
Material: Steel — Pre -Galvanized to G40 Spec
(DTOLC0
Function: Designed primarily to support substantially heavier loads
than is normally intended for the nominal hanger size. Used E &us
extensively to support trapeze installations and the increased loads LISTED
from both above and below the trapeze assembly.
Features: Furnished with 3/8"-16 or 1/2"-13 adjusting threaded ring nut.
Approvals: Underwriters Laboratories listed in the USA (UL) and
Canada' (WL). Conforms to Federal Specification WW-H-171 E &
A-A-1192A, Type 10 and Manufacturers Standardization Society
ANSI/MSS SP-69 & SP-58, Type 10.
Maximum Temperature: 650OF (343°C)
Finish: Pre -Galvanized
Order By: Part number, pipe size and rod size.
Important Design Note. Because of the increased loads applied to the
trapeze assembly, both the upper trapeze supports as well as the lower
hanging unit must be able to hold the maximum loads intended.
-------- -------
TT
f
---------- - - - - -- L_J
200H-2-%
Pipe
2"
Size
(50)
Rod Size
3/8"-16
49/16"
A
(115.9)
37/32"
B
(81.7)
Max. Rec.
1200
Load
(5.34)
Approx.
48
Wt./1 00
(21.8)
200H-2-1/2
2"
(50)
1/2"-13
423/32"
(119.8)
33/8"
(85.7)
1200
(5.34)
45
(20.4)
200H-21/2-%
21/2"
(65)
3/8"-16
55/16"
(134.9)
323/32"
(94.4)
1200
(5.34)
59
(26.7)
200H-21/2-1/2
21/2"
(65)
1/2"-13
515/32"
(138.9)
37/8"
(98.3)
1200
(5.34)
56
(25.4)
200H-3-%
3"
(75)
3/8"-16
53/4"
(146.0)
327/32"
(97.6)
1200
(5.34)
63
(28.6)
200H-3-1/2
3"
(75)
1/2"-13
57/8"
(148.1)
331/32"
(100.8)
1200
(5.34)
60
(27.2)
200H-4-3/8
4"
(100)
3/8"-16
67/8"
(174.6)
47/16"
(112.7)
1200
(5.34)
76
(34.5)
200H-4-1/2
4"
(100)
1/2"-13
71/32"
1 (178.6)
1 419/32"
1 (1116.7)
1 1200
1 (5.34)
73
1 (33.1)
Select trapeze pipe size based on section modulus required for span of trapeze per information provided in
NFPA 13 (2002) Table 9.1.1.6.1 (a and b).
All sizes are UL Listed to support up to 8" pipe at max spacing per NFPA 13.
For 6" (15omm) and 8" (200mm) trapeze pipe, consult factory.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
62
B-Line
by E:T■N
Pipe Hangers
B3198H - Hinged Extension Split Pipe Clamp (ToLCo Fig. 302)
Size Range: 3/8" (10mm) to 3" (80mm) pipe
Material: Malleable Iron
Function: Designed for suspending non -insulated pipe horizontally or vertically.
Approvals: Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 25
and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 12.
Standard Finish: Plain or Electro-Galvanized
Order By: Part number and finish.
Part No.
B3198H-3/8
Pipe
in.
3/8"
Size
(MM)
(10)
Rod Size
A
3/8"-16
C
ri-7 (MM)
31/32" (24.6)
Design
Lbs.
180
Load
kN
(.80)
Approx. Wt./1 00
Lbs. kg
9 (4.1)
B3198H-1/2
1/2"
(15)
3/8"-16
11/16"
(27.0)
180
(.80)
12 (5.4)
B3198H-3/4
3/4"
(20)
3/8"-16
17/32"
(30.9)
180
(.80)
12 (5.4)
B3198H-1
B3198H-11/4
1"
(25)
3/8"-16
111/32"
(34.1)
180
(.80)
(.80)
13 (5.9)
18 (8.1)
11/4"
(32)
3/8"-16
119/32"
(39.7)
180
B3198H-11/2
11/2"
(40)
3/8"-16
123/32"
(43.6)
180
(.80)
21
(9.5)
B3198H-2
2"
(50)
3/8"-16
2"
(50.8)
180
(.80)
44
(19.9)
B3198H-21/2
21/2"
(65)
1/2"-13
211/32"
(59.5)
300
(1.33)
73
(33.1)
B3198H-3
3"
(80)
1/2"-13
223/32"
(69.0)
300
(1.33)
95
(43.1)
B3198R - Extension Split Pipe Clamp
Size Range: 3/8" (10mm) to 4" (100mm) pipe
Material: Malleable Iron
Function: Designed for suspending non -insulated pipe horizontally or vertically.
Approvals: Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 25
and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 12.
Standard Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes
and materials.
Order By: Part number and finish.
Part No.
Rod
B319811-3/8
Pipe
3/8"
Size
(10)
Rod
Thread Size
3/8"-16
31/32"
G
(24.6)
Design
180
Load
(.80)
Approx.
12
Wt./1100
(5.4)
13319811-1/2
1/2"
(15)
3/8"-16
11/16"
(27.0)
180
(.80)
16
(7.2)
13319811-3/4
3/4"
(20)
3/8"-16
17/32"
(30.9)
180
(.80)
18
(8.1)
B3198R-1
1"
(25)
3/8"-16
111/32"
(34.1)
180
(.80)
24
(10.9)
13319811-11/4
11/4"
(32)
3/8"-16
119/32"
(39.7)
180
(.80)
29
(13.1)
B3198R-11/2
11/2"
(40)
3/8"-16
123/32"
(43.6)
180
(.80)
32
(14.5)
B3198R-2
2"
(50)
3/8"-16
2"
(50.8)
180
(.80)
39
(17.7)
B3198R-21/2
21/2"
(65)
1/2"-13
211/32"
(59.5)
300
(1.33)
115
(52.1)
B3198R-3
3"
(80)
1/2"-13
223/32"
(69.0)
300
(1.33)
140
(63.5)
13319813-4
4"
(100)
1/2"-13
311/32"
(84.9)
300
(1.33)
160
(72.6)
A
(Rod Size)
Hanger Rod Not
Included
A
- ead Size)
er Rod Not
cluded
B-Une
by FIT-N
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
63
Pipe Hangers & Supports
Pipe Hangers
B3198HCT - Hinged Extension Split Pipe Clamp (ToLCO Fig. 301CT)
Size Range: 1/2" (15mm) to 2" (5omm) copper tubing
Material: Malleable Iron
Function: A rigid support to suspend tubing
horizontally or vertically.
Approvals: Conforms to Federal Specification
WW-H-171 E & A-A-1192A, Type 25 and Manufacturers
Standardization Society ANSI/MSS SP-69 & SP-58,
Type 12.
Standard Finish: DURA-COPPERT"
Order By: Part number and finish.
B3198HCT-1/2
Tubing Size
1/2" (15)
Rod Size
3/8"-16
C
5/8" (15.9)
Design Load
180 (80)
Approx.11
8 (3.6)
B3198HCT-3/4
3/4"
(20)
3/8"-16
13/16" (20.6)
180
(.80)
10
(4.5)
B3198HCT-1
1"
(25)
3/8"-16
15/16" (23.8)
180
(.80)
10
(4.5)
B3198HCT-11/4
11/4"
(32)
3/8"-16
11/8" (28.6)
180
(.80)
14
(6.3)
B3198HCT-11/2
11/2"
(40)
3/8"-16
19/16" (39.7)
180
(80)
18
(8.1)
B3198HCT-2
2"
(50)
3/8"-16
17/8" (47.6)
180
(.80)
23
(10.4)
B3198RCT - Extension Split Pipe Clamp
Size Range: 1/2" (15mm) to 2" (50mm) copper tubing
Material: Malleable Iron
Function: A rigid support to suspend tubing horizontally or
vertically.
Approvals: Conforms to Federal Specification WW-H-171 E
& A-A-1192A, Type 25 and Manufacturers Standardization
Society ANSI/MSS SP-69 & SP-58, Type 12.
Standard Finish: DURA-COPPERTM
Order By: Part number and finish.
B3198RCT-3/8
Tubing'id
3/8" (10)
Size
3/8"-16
C
11/16" (17.5)
Design
180
i.d
(.80)
Approx. Wt./100
12 (5.4)
B3198RCT-1/2
1/2"
(15)
3/8"-16
111/16"
(17.5)
180
(.80)
12
(5.4)
B3198RCT-3/4
3/4"
(20)
3/8"-16
7/8"
(22.2)
180
(.80)
14
(6.3)
B3198RCT-1
1"
(25)
3/8"-16
11f16"
(27.0)
180
(.80)
17
(7.7)
B3198RCT-11/4
11/4"
(32)
3/8"-16
11/8"
(28.6)
180
(.80)
17
(7.7)
B3198RCT-11/2
11/2"
(40)
3/8"-16
15/16"
(33.3)
180
(.80)
22
(10.0)
B3198RCT-2
2"
(50)
3/8"-16
11/2"
(38.1)
180
(.80)
26
(11.8)
A
lod Size)
anger Rod
[Included
A
.ad Size)
ger Rod
Included
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
64
B-Line
by E:T■N
Pipe Hangers
B3175 - Ring and Bolt Hanger
Size Range: 1/2" (15mm) to 6" (150mm) pipe
Material: Pre -Galvanized Steel
Function: Designed for suspending light -weight non -insulated pipe.
(Use with B3222 eye socket or B3224 hanger adjuster).
Standard Finish: Pre -Galvanized
Order By: Part number and finish.
Bolt and Nut Included
size
Steel Size
B3175-1/2
Pipe
1/2"
Size
(15)
11/16"
C
(27.0)
:o
1/4"-20
Steel
18 Ga. x 7/8"
Size
(1.2 x 22.2)
Design
275
Load
(1.22)
Approx.
7.5
Wt./100
(3.4)
B3175-3/4
3/4"
(20)
13/16"
(30.2)
1/4"-20
18 Ga. x 7/8"
(1.2 x 22.2)
275
(1.22)
8.0
(3.6)
B3175-1
ill
(25)
15/16"
(33.3)
1/4"-20
18 Ga. x 7/8"
(1.2 x 22.2)
275
(1.22)
9.0
(4.1)
B3175-11/4
11/4"
(32)
11/2"
(38.1)
1/4"-20
18 Ga. x 7/8"
(1.2 x 22.2)
275
(1.22)
10.5
(4.7)
B3175-11/2
11/2"
(40)
15/8"
(41.3)
1/4"-20
18 Ga. x 7/8"
(1.2 x 22.2)
275
(1.22)
11.5
(5.2)
B3175-2
2"
(50)
113/16"
(46.0)
1/4"-20
18 Ga. x 7/8"
(1.2 x 22.2)
275
(1.22)
13.0
(5.9)
B3175-21/2
21/2"
(65)
25/16"
(58.7)
5/16"-18
16 Ga. x 11/4"
(1.5 x 31.7)
500
(2.22)
30.0
(13.6)
B3175-3
3"
(80)
25/8"
(66.7)
5/16"-18
16 Ga. x 11/4"
(1.5 x 31.7)
500
(2.22)
35.0
(15.9)
B3175-31/2
31/2"
(90)
27/8"
(73.0)
5/16"-18
16 Ga. x 11/4"
(1.5 x 31.7)
500
(2.22)
38.5
(17.4)
B3175-4
4"
(100)
31/8"
(79.4)
5/16"-18
16 Ga. x 11/4"
(1.5 x 31.7)
500
(2.22)
42.0
(19.0)
B3175-5
5"
(125)
35/8"
(92.1)
5/16"-18
16 Ga. x 11/4"
(1.5 x 31.7)
500
(2.22)
51.0
(23.1)
B3175-6
6"
(15o)
43/16"
(106.4)
5/16"-18
16 Ga. x 11/4"
(1.5 x 31.7)
500
(2.22)
58.5
(26.5)
B3175CT - Ring and Bolt Hanger, DURA-COPPERTM Coated
Bolt and Nut Included
Size Range: 1/2" (15mm) to 4" (100mm) pipe
Material: Pre -Galvanized Steel
Function: Designed for suspending copper tubing allowing for vertical
adjustment. (Use with B3222 eye socket or B3224 hanger adjuster).
Standard Finish: DURA-COPPERTM
Order By: Part number and finish.
sae
Steel Size
B3175CT-1/2
Tubing Size
1/2" (15)
15/16"
C
(33.3)
:o
1/4"-20 X 1"
Steel
1/16" X 7/8"
Size
(1.6 x 22.2)
Design Load
200 (.89)
Approx. Wt./100
8 (3.6)
B3175CT-3/4
3/4"
(20)
13/8"
(34.9)
1/4"-20 X 1 "
1/16" X 7/8"
(1.6 x 22.2)
200
(.89)
8
(3.6)
B3175CT-1
1"
(25)
13/16"
(30.2)
1/4"-20 x 1"
1/16" x 7/8"
(1.6 x 22.2)
200
(.89)
8
(3.6)
B3175CT-11/4
11/4"
(32)
15/16"
(33.3)
1/4"-20 x 1"
1/16" x 7/8"
(1.6 x 22.2)
200
(.89)
10
(4.5)
B3175CT-11/2
11/2"
(40)
11/2"
(38.1)
1/4"-20 x 1"
1/16" x 7/8"
(1.6 x 22.2)
200
(.89)
11
(5.0)
B3175CT-2
2"
(50)
115/16"
(49.2)
1/4"-20 x 1 "
1/16" x 7/8"
(1.6 x 22.2)
200
(.89)
11
(5.0)
B3175CT-21/2
21/2"
(65)
23/16"
(55.6)
1/4"-20 x 1"
1/16" x 7/8"
(1.6 x 22.2)
200
(.89)
12
(5.4)
B3175CT-3
3"
(80)
211/16"
(68.3)
1/4"-20 x 1"
1/16" x 7/8"
(1.6 x 22.2)
200
(.89)
14
(6.3)
B3175CT-31/2
31/2"
(90)
215/16"
(74.6)
1/4"-20 x 1"
1/16" X 7/8"
(1.6 x 22.2)
200
(.89)
16
(7.2)
B3175CT-4
4"
(too)
33/16"
(81.0)
1/4"-20 x 1"
1/16" x 7/8"
(1.6 x 22.2)
200
(.89)
18
(8.1)
B-Une
by E:T-IN
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
65
Pipe Hangers & Supports
Pipe Hangers
B3190 Return Line Offset J-Hook (TOLco Fig. 40)
Size Range: 1/2" (15mm) to 8" (200mm) pipe
Material: Steel (Stainless steel available)
Function: Recommended for supporting light pipe runs with a 1 " (25.4) offset from mounting surfaces.
Standard Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials.
Order By: Part number and finish.
B3190-1/2
Pipe
1/2"
Size
(15)
Design
200
Load
(.89)
Approx.
54
Wt./1 00
(24.5)
B3190-3/4
3/4"
(20)
200
(.89)
55
(24.9)
B3190-1
1 "
(25)
200
(.89)
78
(35.4)
B3190-11/4
11/4"
(32)
200
(.89)
85
(38.5)
B3190-11/2
11/2"
(40)
200
(.89)
90
(40.8)
B3190-2
2"
(50)
200
(.89)
98
(44.4)
B3190-21/2
21/2"
(65)
350
(1.55)
126
(57.1)
B3190-3
3"
(80)
350
(1.55)
136
(61.7)
B3190-31/2
31/2"
(90)
350
(1.55)
147
(66.8)
B3190-4
4"
(100)
450
(2.00)
235
(106.6)
B3190-5
5"
(125)
450
(2.00)
350
(158.7)
B3190-6
B3190-8
6"
(150)
450
(2.00)
383
(173.7)
8"
1 (200)
1 450
(2.00)
605
(274.4)
B3191 Return Line Straight J-Hook (Tosco Fig. 41)
1"
(25.4)
9/1611 Dia.
(14.3)
5" /
(127.0)
Size Range: 112" (15mm) to 8" (200mm) pipe
Material: Steel (Stainless steel available)
Function: Recommended for supporting light pipe runs flush with the mounting surfaces.
Standard Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials.
Order By: Part number and finish.
B3191-1/2
Pipe
1/2"
Size
(15)
Design Load
200 (.89)
Approx.
54
Wt./1 00
(24.5)
B3191-3/4
3/4"
(20)
200
(.89)
55
(24.9)
B3191-1
1 "
(25)
200
(.89)
76
(34.5)
B3191-11/4
11/4"
(32)
200
(.89)
82
(37.2)
B3191-11/2
11/2"
(40)
200
(.89)
87
(39.4)
B3191-2
2"
(50)
200
(.89)
96
(43.5)
B3191-21/2
21/2"
(65)
350
(1.55)
124
(56.2)
B3191-3
3"
(80)
350
(1.55)
134
(60.8)
B3191-31/2
31/2"
(90)
350
(1.55)
145
(65.8)
B3191-4
4"
(100)
450
(2.00)
153
(69.4)
B3191-5
5"
(125)
450
(2.00)
348
(157.8)
B3191-6
6"
(150)
450
(2.00)
381
(172.8)
B3191-8
1 8"
1 (200)
1 450
(2.00)
600
(272.1)
9/16" Dia.
(14.3)
5"
(127.0)
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
66
B-Line
by E:T■N
Pipe Hangers
Fig. 120RWA - (Model B) Retrofit Wrap Around "U" Hanger Clamp
Size Range: 1 " (25mm) thru 6" (15omm) pipe
Material: Steel
Function: Designed to restrain movement of the pipe within standard
U-hangers as required by NFPA 13. Where retrofit capability is crucial, the
Fig. 120RWA is a labor efficient alternative to the standard Cooper B-Line
Fig. 120W wrap around U-hanger.
Features Installs easily by tightening two hex nuts. Features a unique
bracing slot that locks onto a standard U-hanger to become a solid unit that
will stabilize the pipe during seismic activity or sprinkler head activation.
Designed to be used in retrofit or new construction applications. Will clamp
to existing U-Hangers without restriction to leg angle.
Approvals: Underwriters Laboratories listed in the USA (UL) and Canada
(cUL) as a restrainer. Included in our Seismic Restraints Catalog approved
by the State of California Office of Statewide Health Planning and
Development (OSHPD). For additional load, spacing and placement
information relating to OSHPD projects, please refer to the Cooper B-Line
Seismic Restraint Systems Guidelines. NFPA 13 (2010) 9.3.6.3.
Finish: Plain and Galvanized. Contact B-Line for alternative finishes and
materials.
Order By: Part number, type numbers and pipe size
Ordering Note: Order by the following type and pipe size:
Type 1 — (1" (25mm) and 11/4" (32mm) pipe size)
Type 2 — (11/2" (40mm) and 2" (50mm) pipe size)
Type 3 — (21/2" (65mm) and 3" (80mm) pipe size)
Type 4 — (4" (100mm) pipe size)
Type 6 — (5" (125mm) and 6" (150mm) pipe size)
Important Note: The bracing slot feature is sized to fit the U-Hanger rod
schedule as required by NFPA 13 as follows:
5/16" (7.9mm) rod for up to 2" (5omm) pipe
3/8" (9.5mm) rod for 21/2" (65mm) - 6" (160mm) pipe
For other rod size requirements consult factory.
120RWA-TYPE1-1
,.Pipe
1
1
Size
1" (20)
11/4" (25)
120RWA-TYPE1-11/4
120RWA-TYPE2-11/2
2
2
11/2"
2"
(40)
(50)
120RWA-TYPE2-2
120RWA-TYPE3-21/2
3
21/2"
(65)
120RWA-TYPE3-3
3
3"
(80)
120RWA-TYPE4-31/2
4
31/2"
(90)
120RWA-TYPE4-4
4
4"
(100)
120RWA-TYPE6-5
6
5"
(125)
120RWA-TYPE6-6
6
6"
1 (150)
Component of State of
California OSHPD Approved
Seismic Restraints System
t)TaL.CQ- G &us
LISTED
B-Line
by E:TlN
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
67
Pipe Hangers & Supports
Pipe Hangers
Fig. 120 - "U" Hanger
Size Range: Size 3/4" (20mm) thru 8" (200mm) pipe STD!
Material: Steel
Function: Used to support piping from wood beams
where no contraction is expected. Used extensively in
automatic fire sprinkler systems.
Approvals: Meets or exceeds the requirements of
National
Fire Protection Association (NFPA), Pamphlet 13. Included
in our Seismic Restraints Catalog approved by the State of
California Office of Statewide Health Planning and
Development (OSHPD). For additional load, spacing and
placement information relating to OSHPD projects, please
refer to the Seismic Restraint Systems Guidelines. Le
Maximum Temperature: 750OF (399°C) (Sp
Finish: Plain. Contact B-Line for alternative finishes and
materials.
Order By: Part number, pipe size, length and finish
120-3/4
Pipe
3/41,
Size
(20)
A
5/16"
(7.9)
Fastener Size
16 x 2*
Max. Rec.
250
Load***
(1.11)
120-1
1"
(25)
5/16"
(7.9)
16 x 2*
250
(1.11)
120-11/4
11/4"
(32)
5/16"
(7.9)
16 x 2*
250
(1.11)
120-11/2
11/2"
(40)
5/16"
(7.9)
16 x 2*
250
(1.11)
120-2
2"
(50)
5/16"
(7.9)
16 x 2*
250
(1.11)
120-21/2
21/2"
(65)
3/8"
(9.5)
3/8 x 21/2**
320
(1.42)
120-3
3"
(80)
3/8"
(9.5)
3/8 x 21/2**
320
(1.42)
120-31/2
31/2"
(90)
3/8"
(9.5)
3/8 x 21/2**
560
(2.49)
120-4
4"
(100)
3/8"
(9.5)
1/2 x 3**
560
(2.49)
120-5
5"
(125)
1/2"
(12.7)
1/2 x 3**
560
(2.49)
120-6
6"
(150)
1/2"
(12.7)
1/2 x 3**
760
(3.38)
120-8
8"
(200)
1/2"
(12.7)
5/8 x 3**
--
( )
" Drive Screw
** Lag Bolt
With minimum safety factor of 5
Fastener schedule per NFPA
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
68
B-Line
by IFA-N
Fig.120MJ - Mutt & Jeff "U" Hanger
Size Range: Size 3/4" (20mm) thru 8" (200mm) pipe
Material: Steel
Function: Used to support piping from wood beams where
no
contraction is expected. Used extensively in automatic fire
sprinkler systems. Fig. 120MJ is used when the wood beam is
on a diagonal.
Finish: Plain. Contact B-Line for alternative finishes and
materials.
Order By: Part number, side length and finish
120MJ-3/4
Pipe
3/4"
Size
(20)
A
5/16" (7.9)
Fastener Size
16 x 2*
Max. Rec.
250
Load***
(1.11)
120MJ-1
1"
(25)
5/16"
(7.9)
16 x 2*
250
(1.11)
120MJ-11/4
11/4"
(32)
5h6"
(7.9)
16 x 2*
250
(1.11)
120MJ-11/2
11/2"
(40)
5h6"
(7.9)
16 x 2*
250
(1.11)
120MJ-2
2"
(50)
5h6"
(7.9)
16 x 2*
250
(1.11)
120MJ-21/2
21/2"
(65)
3/8"
(9.5)
3/8 x 21/2**
320
(1.42)
120MJ-3
3"
(80)
3/8"
(9.5)
3/8 x 21/2**
320
(1.42)
120MJ-31/2
31/2"
(90)
3/8"
(9.5)
3/8 x 21/2**
560
(2.49)
120MJ-4
4"
(100)
3/8"
(9.5)
1/2 x 3**
560
(2.49)
120MJ-5
5"
(125)
1/2"
(12.7)
1/2 x 3'
560
(2.49)
120MJ-6
6"
(150)
1/2"
(12.7)
1/2 x 3**
760
(3.38)
120MJ-8
8"
(200)
1 1/2"
1 (12.7)
5/8 x 3'
-
(--)
Fig.120W - Wrap Around "U" Hanger
Size Range: Size 3/4" (20mm) thru 2" (50mm) pipe
Material: Steel
Function: Required for automatic fire protection agencies to
be used on the end of branch lines to prevent pipe from
whipping vertical and striking ceiling or beam.
Finish: Plain. Contact B-Line for alternative finishes and
materials.
Order By: Part number, side length and finish
120W-3/4
Pipe
3/4"
Size
(20)
A
5/16"
(7.9)
Fastener Size
16 x 2*
Max. Rec.
250
Load***
(1.11)
120W-1
1 "
(25)
5/16"
(7.9)
16 x 2*
250
(1.11)
120W-11/4
11/4"
(32)
5/16"
(7.9)
16 x 2*
250
(1.11)
120W-11/2
11/2"
(40)
5/16"
(7.9)
16 x 2*
250
(1.11)
120W-2 1
2"
(50)
5/16"
(7.9)
16 x 2*
1 250
1 (1.11)
Lei
(Sp,
* Drive Screw
** Lag Bolt
*** With minimum safety factor of 5
Fastener schedule per NFPA
Lei
(Spi
* Drive Screw
*** With minimum safety factor of 5
Fastener schedule per NFPA
Beam Clamps
Fig. 65 - Reversible Steel C-Type Beam Clamp 3/411 (19.omm) Throat Opening
Fig. 65XT - Reversible Steel C-Type Beam Clamp 3/41, (19.omm) Throat Opening (bottom of page)
Size Range:
Fig. 65 - 1/2"-13 rod sizes, and 5/8"-11 rod sizes (8)TOLCO
Fig. 65XT - 3/8"-16 rod size (see below)
Material: Steel with hardened cup point set screw and jam nut
Function: Recommended for hanging from steel beam where flange thickness does
not exceed 3/4" (19.Omm).
Features: All steel construction eliminates structural deficiencies associated with
casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip
allows hanging from top flange where clearance is limited.) May be installed with set
screw in up or down position. Offset design permits unlimited rod adjustment by
allowing the rod to be threaded completely through the clamp. Open design permits
inspection of thread engagement.
Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL).
Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13,
3/8"-16 rod will support 1/2" (15mm) thru 4" (10omm) pipe
1/2"-13 rod will support 112" (15mm) thru 8" (200mm) pipe
Included in the Seismic Restraints Catalog approved by the State of California
Office of Statewide Health Planning and Development (OSHPD). For additional
load spacing and placement information relating OSHPD projects, please refer to
the Seismic Restraint System Guidelines.
Finish: Plain. Contact B-Line for alternative finishes and materials.
Order By: Part number and finish
Fig. 65 Patent #4,570,885
Part F Mac Rec. Load * Approx. Wt./100
No. in. (mm) in. (mm) in. (mm)
Maximum loads for clamp with set screw in up or down position.
Note: See page 27 for recommended setscrew torque.
Fig. 65XT-3/8 - Beam Clamp
Feature: Extruded holes allow for more thread
engagement of threaded rod and set screw.
Weight: Approx. Wt./100 - 28.0 Lbs. (12.7kg)
Design Load: 730 Lbs (3.25kN)
Finish: Plain or Electro-Galvanized
Order By: Part number and finish
Approvals: Underwriters Laboratories Listed
and FM Approved for uo to 4" (100mm) pipe.
Component of State of
California OSHPD Approved
Seismic Restraints System
C &us
LISTED
Set Screw and
Locknut Included
C @ US
(PTOLCO-
11/8..
(28.6)
�FMo
LISTED
JI//
19/16"
5� /1
3/5. y
3/411
(19.0)
a��PAN /
�
� f
7/8"
Set Screw and
Locknut Included
13/811 (zz.z)
(34.9)
Note: See page 27 for recommended setscrew torque.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
by E:T*N Line 33 Pipe Hangers & Supports
by
BULL MOOSE TUBE COMPANY
c@us LISTED
FM
APPROVED
no 0NFM
NFPA
ull Moose Tube° is a customer focused,
growth oriented manufacturer and
marketer of tubular products, where
success is based on a commitment
to meeting the customer's perception
of quality.
Our strength resides in our people
working together to satisfy customers
and to promote business growth by
achieving superior financial performance.
www.BuilMooseTube.com
sales@bullmoosetube.com
800.325.4467
BULL MOOSE TUBE COMPANY
Bull Moose Tube's® "Eddy Pipe®"
brand sprinkler pipe is produced to
meet sprinkler pipe standards and
applications.
c@usLISTED
FM
APPROVED
C � UAGM
NFPA
ADVANTAGES OF BULL MOOSE TUBE° EDDY PIPE° FAMILY
• All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual.
• Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for
roll grooving, welding, threading, and plain end fittings.
• All products are certified to ASTM A135 and A795 Type E, Grade A.
• Available in specific cut to order lengths from regular mill rollings.
• More popular sizes available with coating or bare.
• Ultra Eddy°, Eddy Flow°, Eddylite°, and Eddythread 400 offer cost
savings along with superior hydraulics without compromising service life.
• Sprinkler pipe inventory stocked in Masury Ohio; Gerald, Missouri;
Casa Grande, Arizona; Kent, Washington; and Dallas, Texas.
• All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD
III MIC preventative coating.
• Bull Moose Tube° sprinkler pipe is FBCTM compatible.
PRODUCTS
• Schedule 10 and Schedule 40: FM approved and UL listed
sprinkler pipe.
• Eddythread 400: Light threadable Schedule 40 replacement
with corrosion resistance ratio of 1.0.
• Eddylite°: Lightwall threadable with standard outside diameter.
• Eddy Flow®: Cost effective replacement for Schedule 10.
• Ultra Eddy®: Lightwall roll groovable pipe.
• Bull Moose galvanized steel sprinkler pipe is hot dipped
galvanized to meet ASTM A123 standards. All products are
stencilled to meet FM & UL specifications.
PROTECTION
• Eddy Guard II®: Bull Moose Tube° is producing product that can resist
bacteriological growth even after multiple rinse -outs. You know
MIC corrosion can impact your installation and your property. Specify
Bull Moose Tube® "Eddy Guard II®" and feel comfortable knowing
that you are getting Eddy Pipe® product you trust with the bacteria
resistance you need. Eddy Guard II® is NFPA 13 and NFPA 13R system
compatible for use in hybrid systems as well as FM approved.
All information contained herein is accurate as known at the time of publication.
Bull Moose Tube® reserves the right to change product specifications without notice
and without incurring obligation.
Bull Moose Tube's® Schedule
10 and Schedule 40 are FM
Approved and UL Listed (for U.S.
and Canada), even though these
products do not require separate
approvals and listings. Bull
Moose Tube® made the decision
to have them approved and listed.
Our Schedule 10 and Schedule 40
have a pressure rating of 300 PSI
and have been through the same
rigorous testing as our other fine
pipe products. Schedule 10 can be
supplied roll grooved or plain end.
Bull Moose Tube's® Schedule 10
and Schedule 40 pipes are hot
dipped galvanized to meet ASTM
All 23 standards. All products are
stencilled to meet FM & UL
specifications.
c@usLISTED
FM
APPROVED
no 0 N
NiFW gµnnw. aa.cevuen
E--If7 :1 =1 ■1■], =111110 [a7,1 ;J =IF --I :J =110q I;A -1,4 III [•] 04 E-~
NOMINAL PIPE
O.D.
I.D.
WATER FILLED
BUNDLE
SIZE (IN)
(IN)
(IN)
CRR**
WEIGHT/FT
WEIGHT
SIZE
1
1.315
1.097
15.27
1.41 1bs/ft
1.820
91
1-1/4
1.660
1.442
9.91
1.81 1bs/ft
2.518
61
1-1/2
1.900
1.682
7.76
2.09lbs/ft
3.053
61
2
2.375
2.157
6.27
2.641bs/ft
4.223
37
2-1/2
2.875
2.635
4.92
3.531bs/ft
5.893
30
3
3.500
3.260
3.54
4.34lbs/ft
7.957
19
4
4.500
4.260
2.50
5.62lbs/ft
11.796
19
SCHEDULE 40 PIPE SPECIFICATIONS
NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE
SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE
1 1.315 1.049 1.00 1.68lbs/ft 2.055 70
1-1/4 1.660 1.380 1.00 2.271bs/ft 2.918 51
1-112 1.900 1.610 1.00 2.721bs/ft 3.602 44
2 2.375 2.067 1.00 3.661bs/ft 5.114 30
2-1/2* 2.875 2.468 1.00 5.801bs/ft 7.875 30
3* 3.500 3.068 1.00 7.581bs/ft 10.783 19
4* 4.500 4.026 1.00 10.801bs/ft 16.316 19
*Only available in Casa Grande, AZ
**Corrosion Resistance Ratio per latest UL Directory Listing
PIPE PREPARATION
For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak -tight seat for the gasket,
pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt,
chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling
assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used.
° For Additional Information Contact (800) 325-4467 www.builmoosetube.com
Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com
1819 Clarkson Road
Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masur , OH
61JLL MCCSE Tu6ECCMpa y 63017
S]
U t 4
Bull Moose Tube's° Eddythread 40® ADVANTAGES OF BULL MOOSE TUBE° EDDYTHREAD 400
is a lightweight replacement for • Has a Corrosion Resistance Ratio of 1.0.
Schedule 40 that has a Corrosion • Has a pressure rating of 300 psi.
Resistance Ratio of 1. • Is lighter weight than Schedule 40.
• Is approved by Factory Mutual and listed by Underwriters Laboratories.
• Is produced in accordance to ASTM A135 and A795 Type E, Grade A.
• Can be used with standard Schedule 40 threaded fittings, couplings, and valves.
• Is produced from steel with excellent properties of strength and threadability.
• Can be used in wet, preaction, and deluge type sprinkler systems.
• Can be hot dipped galvanized to meet FM's requirement for dry systems.
• Offers lower freight costs.
• Supplied with EDDY GUARD III MIC preventative coating.
c@usLISTED
FM
APPROVED
no
A ova
NiFW gµnnw. aa.cevuen
EDDYTHREAD 40" SPECIFICATIONS
NOMINAL PIPE O.D.
I.D.
WEIGHT
WATER FILLED
BUNDLE
SIZE (IN) (IN)
(IN)
CRR*
LB./FT
WEIGHT
SIZE
1 1.295
1.083
1.00
1.461
1.860
70
1-1/4 1.650
1.418
1.00
2.070
2.754
51
1-1/2 1.900
1.654
1.00
2.547
3.468
44
2 2.375
2.123
1.00
3.308
4.842
30
'Corrosion Resistance Ratio per latest UL Directory Listing
PIPE PREPARATION
For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak -tight seat for the gasket, pipe
surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips,
grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly,
causing leakage. Also, check the manufacturer's instructions for the specific fitting used.
° For Additional Information Contact (800) 325-4467 www.bullmoosetube.com
Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com
1819 Clarkson Road
Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas,TX Masury, OH
HULL MOO! IE COMPANY 63017
5
Page 1 of 6
® MICROFAST° QUICK
4 I KjRESPONSE PENDENT
SPRINKLER VK302 (K5.6)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com
1. DESCRIPTION
The Viking MicrofaW Quick Response Pendent Sprinkler VK302 is a small thermo-
sensitive glass bulb spray sprinkler available with various finishes and temperature
ratings to meet design requirements. The special Polyester and Electroless Nickel
PTFE (ENT) coatings can be used in decorative applications where colors are desired.
In addition, these coatings have been investigated for installation in corrosive atmos-
pheres and are listed/approved as corrosion resistant as indicated in the Approval
Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM
Global has no approval classification for Polyester coatings as corrosion resistant.)
2. LISTINGS AND APPROVALS
cULus Listed: Category VNIV
FM Approved: Class Series 2000
vds VdS Approved: Certificates G414009 and G414010
LPCB LPCB Approved
C E CE Certified: Standard EN 12259-1:1999, A3:2006 Certificate of Constancy of Performance 0832-CPR-SO021
«<` CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF)
Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed.
3. TECHNICAL DATA
Specifications:
Minimum Operating Pressure: 7 psi (0.5 bar)
Rated to 175 psi (12 bar) water working pressure
Factory tested hydrostatically to 500 psi (34.5 bar)
Thread size: 1/2" NPT, 15 mm BSP
Nominal K-Factor: 5.6 U.S. (80.6 metric**)
Glass -bulb fluid temperature rated to -65 °F (-55 °C)
Overall Length: 2-1/4" (58 mm)
*Wl_us Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE
Approvals ONLY is 5 psi (0.35 bar).
Material Standards:
Frame Casting: Brass UNS-C84400 or QM Brass
Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500
Bulb: Glass, nominal 3 mm diameter
Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape
Screw: Brass UNS-C36000
Pip Cap and Insert Assembly: Copper UNS-Cl1000 and Stainless Steel UNS-S30400
For Polyester Coated Sprinklers: Belleville Spring -Exposed
For ENT Coated Sprinklers: Belleville Spring -Exposed, Screw and Pipcap - ENT plated.
Ordering Information: (Also refer to the current Viking price list.)
Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate
suffix for the temperature rating to the sprinkler base part number.
Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN
Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G
For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB
Available Finishes And Temperature Ratings: Refer to Table 1.
Accessories: (Also refer to the current Viking price list.)
Form No. F_033314 17.10.05 Rev 17.2 Replaces Form No. F_033314 Rev 17.1
(Replaced wrench 10896W/B with 21475M/B)
Page 2 of 6
® MICROFAST° QUICK
4 I KjRESPONSE PENDENT
SPRINKLER VK302 (K5.6)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com
Sprinkler Wrenches:
A. Standard Wrench: Part No. 21475M/B (available since 2017).
B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006)
C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010)
**A %" ratchet is required (not available from Viking).
***Allows use from the floor by attaching a length of V diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808.
Sprinkler Cabinets:
A. Six -head capacity: Part No. 01724A (available since 1971)
B. Twelve -head capacity: Part No. 01725A (available since 1971)
4. INSTALLATION
Refer to appropriate NFPA Installation Standards.
5. OPERATION
During fire conditions, the heat -sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and
sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern
to extinguish or control the fire.
6. INSPECTIONS, TESTS AND MAINTENANCE
Refer to NFPA 25 for Inspection, Testing and Maintenance requirements.
7. AVAILABILITY
The Viking Microfast° Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis-
tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation.
8. GUARANTEE
For details of warranty, refer to Viking's current list price schedule or contact Viking directly.
Wrench Flat
Protective Sprinkler Cap
Figure 1:
Standard Sprinkler Wrench 21475M/B
Form No. F_033314 17.10.05 Rev 17.2
Page 3 of 6
® MICROFAST° QUICK 4 I KjRESPONSE PENDENT
SPRINKLER VK302 (K5.6)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com
TABLE 1:
AVAILABLE SPRINKLER TEMPERATURE
RATINGS AND FINISHES
Sprinkler Temperature
Sprinkler Nominal
Maximum Ambient
Bulb Color
Classification
Temperature Rating'
Ceiling Temperature
Ordinary
135 °F (57 °C)
100 °F (38 °C)
Orange
Ordinary
155 °F (68 °C)
100 °F (38 °C)
Red
Intermediate
175 °F (79 °C)
150 °F (65 °C)
Yellow
Intermediate
200 °F (93 °C)
150 °F (65 °C)
Green
High
286 °F (141 °C)
225 °F (107 °C)
Blue
Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT
Corrosion -Resistant Coatings3: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C)
Footnotes
The sprinkler temperature rating is stamped on the deflector.
2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction.
Refer to specific installation standards.
3 The corrosion -resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These
tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are com-
patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces
only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated.
Sprinkler wrench 13655W/B**
for recessed pendent
sprinklers
** A 1/2" ratchet is required
(not available from Viking)
H
Carefully slide the wrench sideways around
the protective cap, ensuring engagement with
the sprinkler wrench flats
Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers
Form No. F_033314 17.10.05 Rev 17.2
Page 4 of 6
® MICROFAST° QUICK
RESPONSE PENDENT
SPRINKLER VK302 (K5.6)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com
Approval Chart 1 (UL)
The Viking Microfast° Quick Response Temperature KEY
Pendent Sprinkler VK302 .� Finish
p Al X F Escutcheon (if applicable)
Maximum 175 PSI (12 Bar) WWP
Base
Sprinkler
Thread Size
Nominal
Overall
Listings and Approvals'
Part
SIN
Style
K-Factor
Length
(Refer also to Design Criteria.)
Number
NPT
I BSP
U.S.
metric,
Inches
mm
cULus°
VdS
LPCB
7
12979
VK302
Pendent
1/2"
15 mm
5.6
80.6
2-1/4
58
A1Z, B1Y, D2, C2X
Al
A1Z, B1Y
D1Z, C1Y
19780
VK302
Pendent
1/2"
5.6
80.6
2-1/4
58
D3
21354
VK302
Pendent
--
15 mm
5.6
80.6
2-1/4
58
D3
NOTICEOffice)
06662B
VK302
Pendent
1/2"
mm
5.6
80.6
2-1/4
58
A1Z,B1YD2,C2X
18021
VK302
Pendent
1/2"[V5
15 mm
5.6
80.6
2-1/4
58
A1X, B1Y
Al
A1X, B1Y
D1X, C1Y8
D1X, C1Y9
Approved Temperature Ratings
Approved Finishes
Approved Escutcheons
A- 135 OF (57 °C), 155 OF (68 °C), 175 OF
1 - Brass, Chrome, White
X - Standard surface -mounted escutcheon or the
(79 °C), 200 OF (93 °C), 286 OF (141 °C)
Polyester5', Black Polyes-
Viking Micromatic® Model E-1 Recessed Escutcheon
B - 135 OF (57 °C), 155 OF (68 °C), 175 OF
terns
Y - Standard surface -mounted escutcheon or the
(79 °C), and 200 OF (93 °C)
2 - ENT'
Viking Microfast° Model F-1 Adjustable Escutcheon, or recessed with the Viking Micro-
C - 155 OF (68 °C), 175 OF (79 °C), and
3 - Chrome
mati& Model E-1, E-2, or E-3 Recessed Escutcheon
200 OF (93 °C)
Z - Standard surface -mounted escutcheon or the
D - 155 OF (68 °C), 175 OF (79 °C), 200 OF
Viking Microfast° Model F-1 Adjustable Escutcheon
(93 °C), 286 OF (141 °C)
Footnotes
Base part number shown. For complete part number, refer to Viking's current price schedule.
, Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process.
° Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada.
s cULus Listed as corrosion -resistant.
s Other colors are available on request with the same Listings and Approvals as the standard colors.
7 CE Certified, Standard EN 12259-1, EC -certificate of conformity 0832-CPD-2001.
8 CE Certified, Standard EN 12259-1, EC -certificates of conformity 0832-CPD-2001 and 0832-CPD-2003.
9 MED Certified, Standard EN 12259-1, EC -certificates of conformity 0832-MED-1003 and 0832-MED-1008.
DESIGN CRITERIA - UL
(Also refer to Approval Chart 1 above.)
cULus Listing Requirements:
The Viking Microfast° Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in
accordance with the latest edition of NFPA 13 for standard spray sprinklers.
• Designed for use in Light and Ordinary occupancies.
• The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed.
IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form
No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in
accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD,
VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan-
dards, whenever applicable.
Form No. F_033314 17.10.05 Rev 17.2
Page 5 of 6
® MICROFAST° QUICK
4 I KJ RESPONSE PENDENT
SPRINKLER VK302 (K5.6)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com
Approval Chart 2 (FM) Temperature KEY
The Viking Microfast® Quick Response Finish
Pendent Sprinkler VK302 A1XF Escutcheon (if applicable)
Maximum 175 PSI (12 Bar) WWP
Base Part
Sprinkler
Thread Size
Nominal K-Factor
Overall Length
FM Approvals'
Number'
SIN
Style
(Refer also to Design Criteria.)
NPT
BSP
U.S. metric2
Inches
mm
12979
VK302
Pendent
1/2"
15 mm
5.6 80.6
2-1/4
1 58
A1Z, B1Y, D2X, C2
ProductNOTICE -
06662B
VK302
Pendent
1/2"
15 mm
5.6
80.6
2-1/4
58
A1Z, B1Y, D2X, C2
18021
VK302
Pendent
1/2"
15 mm
1 5.6
80.6
2-1/4
58
1 A1Z, B1Y
Approved Escutcheons
Approved Temperature Ratings
X - Standard surface -mounted escutcheon or the
A- 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F
Viking Micromatic° Model E-1 Recessed
(93 °C), 286 °F (141 °C)
Approved Finishes
Escutcheon
B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and
1 - Brass, Chrome, White Polyester°,
Y - Standard surface -mounted escutcheon or the
200 °F (93 °C)
and Black Polyester°
Viking Microfast° Model F-1 Adjustable Escutcheon,
C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286
2 - ENT5
or recessed with the Viking Micromatic° Model E-1
°F (141 °C)
or E-2 Recessed Escutcheon
D - 155 °F (68 °C), 175 °F (79 -C), 200 °F (93 °C)
Z - Standard surface -mounted escutcheon or the
Viking Microfast° Model F-1 Adjustable Escutcheon
Footnotes
' Base part number shown. For complete part number, refer to Viking's current price schedule.
2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by
10.0.
3 This table shows the FM Approvals available at the time of printing. Other approvals may be in process.
° Other colors are available on request with the same Approvals as the standard colors.
5 FM approved as corrosion resistant.
DESIGN CRITERIA - FM
(Also refer to Approval Chart 2 above.)
FM Approval Requirements:
The Viking Microfast° Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non -storage pendent sprinklers
as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss
Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not
limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable
spacing, and deflector distance below the ceiling.
NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria.
IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page
F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac-
cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB,
APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and
standards, whenever applicable.
Form No. F_033314 17.10.05 Rev 17.2
Page 6 of 6
N4 I Ki® MICROFAST° QUICK
RESPONSE PENDENT
SPRINKLER VK302 (K5.6)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com
1 /2"
(15 mm)
NPT`
2-1/4"
(57 mm)
Installed with a standard
1/8" surface -mounted
escutcheon
W Ceiling Opening Size:
2-5/16" (59 mm) minimum
2-1/2" (64 mm) maximum
2-1/8"
(54 mm)
T
1-1 /2"
2"
(38 mm)
(51 mm)
Min.
Max.
Installed with a Microfast Note: At maximum, adapter
Model F-1 Adjustable is exposed 1/2" (13 mm)
Escutcheon from face of ceiling
Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon
Ceiling Opening Size:
2-5/16" (59 mm) minimum
It 2-1/2" (64 mm) maximum
2-1/8" 2-1/8"
(54 mm) (54 mm)
1-1/8" T i 1-1/8„
1-3/4" (29 mm) 2,,,, (29 mm)
(45 mm) Min. (51 mm) Min.
Max. Max.
Installed with a
Model E-1 Recessed
Escutcheon
Installed with a Model
E-2 Thread -on Recessed
Escutcheon
Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons
Form No. F_033314 17.10.05 Rev 17.2
Replaces Form No. F_033314 Rev 17.1
(Replaced wrench 10896W/B with 21475M/B)
no
P e drequnged
Product Features
• Made with Teks® self -drilling fasteners -
no pre -drilling required.
• Install into steel range from
22 gauge —1/2" thicknesses.
• Saves time from traditional methods.
• Reduces installation cost.
• Quick to install using the Sammy Nut
Driver with an 18V cordless drill/driver.
Approvals
Size
Part
Number
Model
Screw
DescriptionsRod
Ultimate
UL Test
I'M Test Min
Max
Box
Case
114"
8024957
DSTR 100 *
1/4-20 x 1"TEKS 3
1510 (20 ga.)
.036"-20 ga
3116"
25
125
1/4"
8025957
DST 100
1/4-14 x 1" TEKS 3
446 (20 ga.)
.036"-20 ga
3/16"
25
125
1/4"
8026957
DST 150
1/4-14 x 1-1/2" TEKS 3
970 (16 ga.)
.036"-20 ga
3/16"
25
125
1/4"
8027957
DST 200
1/4-14 x 2" TEKS 3
446 (20 ga.)
.036"-20 ga
3/16"
25
125
1/4"
8030957
TEK 500
12-24 x 1-1/2" TEKS 5
3125 (3/16")
.187"-3/16"
1/2"
25
125
° , 0
3/8"
8038957
DSTR 1 *
1/4-20 x 1" TEKS 3
1510 (20 ga.)
1500
1475 .036"-20 ga
3/16"
25
125
3/8"
8037957
DSTR 1-1/2 *
12-24 x 1-1/2" TEKS 5
1510 (3/16")
1500
1475 .060"-16 ga.
1/2"
25
125
D. 0
3/8"
8039957
DSTR 516 *
5/16-18 x 1-1/4" TEKS 3
2200 (20 ga.)
1500
1475 .036"-20 ga
1/8"
25
125
3/8"
8040957
DST 10
1/4-14 x 1" TEKS 3
446 (20 ga.)
.036"-20 ga
3/16"
25
125
#14 Black
970 (16 ga.)
Nut Driver
Part # 8113910
3/8"
8077925
DST 10-SS
114-14 x 1"TEKS 3
446 (20 ga.)
036"-20 ga
3/16"
25
125
970 (16 ga.)
3/8"
8041957
DST 15
1/4-14 x 1-1/2" TEKS 3
446 (20 ga.)
.036"-20 ga
3/16"
25
125
970 (16 ga.)
3/8"
8078925
DST 15-SS
1/4-14 x 1-1/2" TEKS 3
446 (20 ga.)
.036"-20 ga
3/16"
25
125
970 (16 ga.)
3/8"
8042957
DST 20
1/4-14 x 2 TEKS" 3
446 (20 ga.)
.036"-20 ga
3/16"
25
125
970 (16 ga.)
3/8"
8043957
DST 25
1/4-14 x 2-1/2" TEKS 3
446 (20 ga.)
.036"-20 ga
3/16"
25
125
970 (16 ga.)
3/8"
8044957
DST 30
1/4-14 x 3" TEKS 3
446 (20 ga.)
.036"-20 ga
3/16"
25
125
970 (16 ga.)
3/8"
8045957
DST516
5/16-18 x 1-1 /4" TEKS 3
1500 (3/16")
1500
1475 .125"-1/8"
1/8"
25
125
O
3/8"
8046957
TEK 50
12-24 x 1-112" TEKS 5
3125 (3/16")
1500
1475 .187"-3/16"
1/2"
25
125
1/2"
8031925
DST 2.0
1/4-14 x 2" TEKS 3
446 (20 ga.)
1/4"
25
125
970 (16 ga.)
.188"-3/16"
1/2"
8033925
DSTR 1.0 *
1/4-20 x 1"TEKS 3
1510 (20 ga.)
.036"-20 ga
3/16"
25
125
1/2"
8034925
DSTR 5.16 *
5/16-18 x 1-1/4" TEKS 3
2220 (20 ga.)
.036"-20 ga
1/8"
25
125
1/2"
8035925
DST 5.16
5/16-18 x 1-114" TEKS 3
1500 (3116")
.125"-1/8"
1/8"
25
125
1/2"
8036925
TEK 5.0
12-24 x 1-1/2" TEKS 5
3125 (3/16")
.187"-3/16"
1/2"
25
125
#14 SW Red
Nut Driver
*Includes retaining
nut
Part # 8114910
}Approvals Rod Part Model Screw Ultimate UL Test I'M Test Min Max Box Case
size Number Descriptions Pullout
3/8" 8137957 SH-DSTR 1 * 1/4-20 x 1" 3220(3/16") 1500 1475 .035" 3116" 1 25 125 }
}I I` *Includes retaining nut (Does not comply with ROHS requirements) #14 Black
Nut Driver
SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into Part # 8113910
contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.
Upper Attachments
B3199R - Ceiling Flange
B3199RCT - Ceiling Flange Dura-Copper Coated B
Overall H
Size Range: 3/8"-16 & 1/2"-13 rod
Material: Malleable Iron (Stainless Steel Type 304 available)
For 1/4" Flat Head
Standard Finish: Plain or Electro-Galvanized Machine screws
B3199RCT is DURA-COPPER" coated or wood Screws
Function: Designed for attaching a hanger or support rod to
beams, ceilings, or walls.
Order By: Part number and finish.
B3199RCT B3199R
Fig. 78 - All Steel Ceiling Plate (8)TOLCO-
Size Range: 3/8"-16 rod
Material: Pre -Galvanized Steel
Function: Attachment to wood beams, ceilings, metal decks
or walls. Can also be welded to steel beams.
Approvals: Underwriters Laboratories Listed in the USA (UL)
and Canada (cUL). Additionally, UL has listed the Fig. 78 with
fasteners as shown in the table below.
Finish: Plain. Contact B-Line for alternative finishes and
materials.
Order By: Part number, rod size and finish c&US
US Patent #5,702,077 LISTED
UL Listed Fastener Table
Pipe Size Qty Fastener Type Material
1/2" - 2"
2
#14 x 11/4" A -point hex -washer -head sheet metal screw
Wood
21/2" - 4"
2
1/4" x 11/2" wood screws*
Wood
1/2" - 2"
2
1/4" x 1 " tek screws
Metal (18 gauge)
1/2" - 2"
2
#14 x 11/4" A -point hex -washer -head sheet metal screw
Wood
1/2" - 2"
2
#14 x 2" A- point- hex -washer -head sheet metal screw
Wood thru 5/8" gyp board
* No pre -drilling
(Rod or Pipe Thread)
Hanger Rod or Pipe Not Included
D
(2 Holes)
i
a
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified
Pipe Hangers & Supports
214
B-Line
by E.Z•N
Cast Iron
CAST IRON THREADED FITTINGS - CLASS 125 (STANDARD)
Fig. 351
90" Elbow
Size Range:'/4" thru 8"
Page 37
IV
Fig. 358
Tee
Size Range:'/4" thru 8"
Page 40
Fig. 487
Flanged Union Gasket Type
Size Range:'h" thru 8"
Page 46
Fig. 387
Square Head Plugs, Cored
Size Range: 3/4" thru 4"
Page 51
46
Fig. 371
90' Elbow - Flange & Screw
Size Range: 21/2" thru 6"
Page 37
%I
Fig. 359
Reducing Tee
Size Range:
1/2" x'/2" x'/4" thru 6" x 6" x 5"
Page 40 - 44
Fig. 367
Concentric Reducer
Size Range: 3/4" x'/2" thru 8" x 6"
Page 47
Fig. 388
Square Head Plugs, Solid
Size Range:'/2" thru 31/2"
Page 51
0
1 C20
Fig.381
Fig.370
Cap
Locknut
I
Size Range: 21/2" thru 8"
Size Range: 21/2" thru 4"
Page 51
Page 52
*9
Fig. 356 & 356R
45' Elbow
(Straight & Reducing)
Size Range: 1/4" thru 8" (Straight)
1" x'/2" (Reducing)
Page 38
IF
Fig. 360
Cross
Size Range:'/2" thru 6"
Page 45
Fig. 368
Eccentric Reducer
Size Range: 3/4" x'/2" thru 6" x 4"
Page 48
fb
Fig. 389
Bar Plugs, Cored
Size Range: 4" thru 8"
Page 51
91
Fig. 356A
221/2" Elbow
Size Range: 3/4" thru 21/2"
Page 38
it
Fig. 361
Cross Reducing
Size Range:
1"x1"x3/4"x3/4"thru 4"x4"x2"x2"
Page 45
fe
Fig. 383
Hex Bushing
Size Range: 11/2" x'/4" thru 10" x 8"
Page 49 - 50
to
Fig. 380
Bar Plugs, Solid
Size Range: 4" thru 8"
Page 51
IN
Fig. 352
90" Reducing Elbow
Size Range: 1/2" x'/4" thru 6" x 5"
Page 39
0
Fig. 366
Screwed Hex Coupling
Size:1 "
Page 46
Fig. 385
Face Bushing
Size Range: 3" x 2" thru 4" x 3"
Page 50
Fig. 390
Countersunk Plugs
Size Range: 1" thru 4"
Page 51
CAST IRON THREADED FITTINGS - CLASS 250 (EXTRA HEAVY)
Fig. 421 Fig. 424 Fig. 425 Fig. 426
90' Elbow 45' Elbow Tee Reducing Tee
Size Range:'/4" thru 3" Size Range:'/2" thru 21/2" Size Range: 1/4" thru 4" Size Range: 3/4" x 3/4" x'/2" thru 2" x 2" x 1112"
Page 52 Page 52 Page 53 Page 53
ANVIL
PF-11.13
Pipe Hangers
Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line B317ONF)
Fig. 20OF - "Trimline" Adjustable Band Hanger with Felt Lining for Copper Tubing (B-Line B317ONFF)
Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line B317ONFc)
Size Range:
Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe ®TOLC❑ C@ us <FM
Material: Steel, Pre -Galvanized to G90 specifications LISTED aP•.o�
Function: For fire sprinkler and other general piping purposes. Knurled
swivel nut design permits hanger adjustment after installation.
Features:
• (1/2" (15mm) thru 2" (5omm)) Flared edges ease installation for all pipe
types and protect CPVC plastic pipe from abrasion. Captured design
keeps adjusting nut from separating with hanger. Hanger is easily
installed around pipe.
• (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in
® B
hanger before installation. Adjusting nut is easily removed.
Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (2oomm)) %' a
in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and
Factory Mutual Engineering Approved (3/4" (20mm) thru 8" (200mm)). "
Conforms to Federal Specifications WW-H-171 E & A-A-1192A, Type 10
and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Fig. 200-1/2 to 200-2 Fig. 200-21/2 to 200-8
Type 10.
Maximum Temperature: 650OF (343°C)
Finish: Pre -Galvanized. Stainless Steel
materials will be supplied with (2) hex nuts
in place of a knurl nut. map
Order By: Part number and pipe size
** Note: For metric hanger rod sizes add the
VOW --
metric rod size to the figure number.
Example: 200M8-11/2 or 200M10-11/2 Fig. 200
Fig. 200C Fig. 20OF
200-1/2
Pipe
1/2"
Size
(15)
Rod
3/8"-16
Size
M8 or M10
A
31/8" (79.4)
25/8"
B
(66.7)
Max. Rec. Load
400 (1.78)
Approx.
11
Wt./1 00
(5.0)
200-3/4
3/4"
(20)
3/8"-16
M8 or M10
31/8"
(79.4)
21/2"
(63.5)
400
(1.78)
11
(5.0)
200-1
1"
(25)
3/8"-16
M8 or M10
33/8"
(85.7)
25/8"
(66.7)
400
(1.78)
12
(5.5)
200-11/4
11/4"
(32)
3/8"-16
M8 or M10
33/4"
(94.0)
27/8"
(73.0)
400
(1.78)
13
(5.9)
200-11/2
11/2"
(40)
3/8"-16
M8 or M10
37/8"
(98.4)
27/8"
(73.0)
400
(1.78)
14
(6.4)
200-2
2"
(50)
3/8"-16
M8 or M10
41/2"
(114.3)
3"
(76.3)
400
(1.78)
15
(6.9)
200-21/2
21/2"
(65)
3/8"-16
M10
55/8"
(142.9)
41/8"
(104.7)
600
(2.67)
27
(12.3)
200-3
3"
(75)
3/8"-16
M10
57/8"
(149.1)
4"
(101.6)
600
(2.67)
29
(13.3)
200-31/2
31/2"
(90)
3/8"-16
M10
73/8"
(187.3)
51/4"
(133.3)
600
(2.67)
34
(15.6)
200-4
4"
(100)
3/8"-16
M10
73/8"
(187.3)
5"
(127.0)
1000
(4.45)
35
(16.0)
200-5
5"
(125)
1/2"-13
M12
91/8"
(231.8)
61/4"
(158.7)
1250
(5.56)
66
(30.2)
200-6
6"
(150)
1/2"13
M12
101/8"
(257.2)
63/4"
(171.4)
1250
(5.56)
73
(33.4)
200-8
8"
1 (200)
1 1/2"-13
M12
131/8"
1 (333.4)
83/4"
(222.2)
1250
(5.56)
136
(62.3)
B-Line
by E.T•N
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
61
Pipe Hangers & Supports
CAL FIRE - RIVERSIDE UNIT
RIVERSIDE COUNTY FIRE DEPARTMENT
OFFICE OF THE FIRE MARSHAL — LA QUINTA CALIFORNIA
78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074
• www.rvcfire.org
April 22, 2022
World Fire Protection INC
41905 Boardwalk Suite B
Palm Desert, CA 92211
Re: TI Fire Sprinkler Plan Review — Dr. HSU
FSS2022-0103 / 79215 CORPORATE CENTRE DR #120, LA QUINTA, CA 92253
The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County
Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions.
The following inspections/tests are required to be witnessed by the Office of the Fire Marshal staff:
1) Overhead Rough: All installed/relocated piping must be visible.
2) Final inspection: All trim is in place, 5-Year certification is current. New/added heads shall be
included in the spare head box compliment.
*Water -flow signal test may be performed during the Final Inspection.
All persons performing work on the automatic fire sprinkler system shall be Certified Sprinkler Fitters or
Registered with the State Fire Marshal for Apprentice or Trainee classification.
The Fire Department approved plans and conditions letter must be at the job site.
Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for
inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131.
All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal
staff at (760)777-7074.
Kohl Hetrick - Fire Safety Specialist
i6RIVERSIDE COUNTY FIRE PROTECTION PLANNING
RECORD OF INSPECTIONS / PERMIT CARD ai�Cv uGKCv
THIS CARD IS TO REMAIN ON SITE AT ALL TIMES.—CALIFORNIA—
INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE.
JOB
ADDRESS:
79215 CORPORATE CTR DR #120
PERMIT#:
FSS2022-0103
AT ED:
4/22/2022
DESCRIPTION:
DR HSU
CONTRACTOR:
WORLD FIRE PROTECTION
HYDRANT SYSTEM
DATE
INITIALS
SPECIAL SUPPRESSION
DATE
INITIALS
Thrust block pre -pour
Door fan test
UG rough piping
Abort test
UG hydro
Mechanical shutdown
Flush
Detector test
Final IF
Deluge/pre-action
SPRINKLER U.G.
Final EF
Thrust block pre -pour
UST/AST TANK
UG rough piping
Installation
UG hydro
Removal
Flush
Emergency shut off
Final IF
Primary piping
FIRE SPRINKLER
Secondary piping
Weld inspection
Dispensers & shear valves
Overhead rough piping
Final E F
Overhead hydro
MISC. INSPECTIONS
UG flush / OK to connect
Spray booths
Main drain/inspectors' test
Hood/duct extinguishing
High pile storage
High pile rack storage
In -rack sprinklers
H.P. vents/access/corridors
Hose racks
Tract access/hydrant verification
Final E F
Access & Address verification
HOOD EXTINGUISHING
OTHER CONST. PERMIT
Detection system
Function test
Gas/electrical shut-off
Nozzle model/placement
Fire alarm connection
Final e F
SPRAY BOOTHS
FIRE CODE PERMIT(S)
Installation
Air flow test
Mechanical interlock
Extinguishing system
Fire alarm connection
Final e F
FIRE ALARM
KNOX SYSTEM
Rough -wire inspection
Building Knox box
Function test
Gate access Knox box/padlock
Duct detectors/velocity
BUILDING INSPECTIONS
24 hr. battery test
T/I final
Sprinkler monitoring
Shell final
Final F'
Final for occupancy
FINAL INSPECTION DATE: INSPECTORS SIGNATURE:
**WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE-
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
INSPECTION NOTES
1. Sway bracing and hangers will be inspected at the time of rough piping inspection.
2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler
Systems)
3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required.
4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test.
5. Contractor shall supply all testing equipment, access and operating instructions at time of test.
6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the
affected system to be covered or hidden.
POLICIES ON FIELD INSPECTIONS
A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when
scheduling inspections. For City of La Quinta inspections call: (760) 777-7131.
B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence
without approved plans.
C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required
to schedule the necessary inspections and be present on site for inspections.
D. RE -INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not
on site or where previously noted corrections have not been completed.
E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into
the structure until clearance has been granted by the Fire Dept and Building Official.
F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance
has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official.
INSPECTION NOTES:
THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE
AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS.
THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180
DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE.
THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE
REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131