FSS2022-0119
Description: DESIGN AND INSTALL (4 ) FIRE SPKRS IN RESIDENTIAL ADDITION Type: FIRE SPRINKLER (WEB) Subtype: RESIDENTIAL - CUSTOM Status: FINALED Applied: 4/1/2022 ECON HOMES Approved: 5/7/2022 KHET Parcel No: 767480012 Site Address: 81930 MOUNTAIN VIEW LN LA QUINTA,CA 92253 Subdivision: TR 26769 Block: Lot: 12 Issued: ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 6/14/2022 KHET Valuation: $2,950.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 1 36 �J Applied to Approved ADDITIONAL CHRONOLOGY NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT SHASTA FIRE PROTECTION INC 72120 NORTHSHORE ST #C THOUSAND PALMS CA 92276 (760)404-1350 jpaulus@shastafire.co m CONTRACTOR SHASTA FIRE PROTECTION INC 72120 NORTHSHORE ST #C THOUSAND PALMS CA 92276 (760)404-1350 jpaulus@shastafire.co m OWNER LARRY OWENS P O BOX 6416 LA QUINTA CA 00000 (760)404-1350 ? Printed: Thursday, April 06, 2023 3:29:57 PM 1 of 3 WSYSiEMS DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE 101-0000-42421 0 $167.00 $167.00 5/7/22 WEB11679 433798200 CREDIT 476633 ECON 49 FAMILY DETACHED FIRE SPRINKLER SYSTEMS - SINGLE 101-0000-42420 0 $250.00 $250.00 5/7/22 WEB11679 433798200 CREDIT 476633 ECON 49 FAMILY DETACHED PC Total Paid for FIRE FEES: $417.00 $417.00 RECORDS 101-0000-42416 0 $11.00 $11.00 5/7/22 WEB11679 433798200 CREDIT 476633 ECON MANAGEMENT FEE 49 Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY 502-0000-43611 0 $5.00 $5.00 5/7/22 WEB11679 433798200 CREDIT 476633 ECON ENHANCEMENT FEE 49 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:•• $433.00 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES DATE DATE APPROVED OVERHEAD ROUGH KHET 5/19/2022 5/19/2022 W/EXCEPTIO PIPING N FIRE FINAL" KHET 6/14/2022 1 6/14/2022 1 APPROVED Printed: Thursday, April 06, 2023 3:29:57 PM 2 of 3 WsYsrEMS 1ST PERMIT TECH - I PERMIT TECH I 4/1/2022 I 4/4/2022 I 4/1/2022 I COMPLETE ETRAKIT (1 DAY) BUCKET BOND INFORMATION Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED 1ST SUBMITTAL CVWD DOC 4/1/2022 Etrakit Contractor RESIDENCE RCCE FORM RCCE FORM FOR 1 OWENS RES 15-080.pdf FROM CVWD DOC 4/1/2022 Etrakit Contractor 1ST SUBMITTAL PLAN 22-015 PLAN REVIEW 1 REVIEW APPLICATION APP 4-1-22.pdf DOC 4/1/2022 Etrakit Contractor 1ST SUBMITTAL PLAN 22-015 FIRE DEP T DEP.pdf 1 SUBMITTAL HARANG RESIDENCE DOC 4/1/2022 Etrakit Contractor 1ST SUBMITTAL ADDITION HYD CALC 4- 1 HYDRAULIC CALCS 1-22.pdf VIKING FREEDOM RES DOC 4/1/2022 Etrakit Contractor SPKR HEAD MATERIAL CONC SSP K4.9 1 SUBMITTAL VK494.pdf DOC 4/1/2022 Etrakit Contractor 1ST SUBMITTAL CPVC BlazeMaster Overview 1 Brochure.pdf FSS2022-0119- FSS2022-0119- DOC 5/7/2022 KOHL HETRICK APPROVED PLANS AND APPROVED PLANS AND 1 CALCS.pdf CALCS.pdf DOC 5/7/2022 KOHL HETRICK FSS2022-0119 - COA FSS2022-0119 - COA 1 AND JOB CARD.pdf AND JOB CARD.pdf Printed: Thursday, April 06, 2023 3:29:57 PM 3 of 3 WsYsrEMS w.w o 00 0 0q I0 0 0 o_P� 1w,P1u�L„�xa,n„ o = D3ffi1i �E enu ulxommncox,P.eEnI 0 I.. N66NNmC "waw6 } Y ® aLvi ® © E = uxOD. er OrxLxs M� ® J re o . w R�.xD E ELEttelt aeu 9 uEx o • f rt k TwO wsr swan sRAC[ O NmeT uRRY OWENs GLSARCHITECT GROUP I (76D1250-1s99 1T601060J528 W S N PROJECT: HARANG RESIDENCE ADDDION 819IO MOUNTAIN VIEW IAI.APN; 262. .p12 UQUINTA, CALIFORNIA 0. FRD: ssP Muwl CoxPAw CVWD 1T60) I98-266, O -McNEON0x CDVOFLADIIINTAFIREDEPT. (]601 T2 M74 p N0• w STAT[ LTC. NO. I—) 4—M (AZ.) 101518 YCENSE CLAN C.16 0RA OaGlOL', PURE PROOVE970H, DaOo Exl s:Dl�aoa.uso OATLI 41-22 aoe ND. �— p E SCALE. NOTED o 72120 Northshore Street Suite P6o16o6n Ds6 Thousand Palms, CalNomia M78 www.shaNafi°es t30�xo. 011 OF 1 4 iasrs 0 0 Tm 4 (M Realdential Conriggion, Charee Estimate ate: November 19, 2015 Customer Name:. Lan I Owens Phone No. (760) 250-1544 Parcel No. 767-480-012. Geo. U6-07-15-1 address: 81930 Mduntain View Ln. La Quinta uD: 666538 Block No. Lot No. J 12 site of Lot: 544,450 sq. ft. Tract No. 26769 Type of Service. �_i; Duplex: i3 Triplex: swse: $ 15,272 5Q Acres:�1.2_5� swsc $12,218.00tre WSBFQ . $ . SCC' Treatment: $2,436/edu conection: $r2,415/edu Meter: $ 400.06 Deter Size: 1 inch Meter surcharge: 2,473:00 service size: 11/2 inch service: : $ Meter & Service: $ Abandon/Rek wm*: Badcflow: $ Other: Notes: Tract No. 26769, Dwg.1k334g a 11/2" service exists. Sewer lateral: $ Per agreement no WSBiFC. no sewer available. Email Total: $ 18,151.50 larryo4962@aol.com PZ 1S-6776 Infor►nation supplied By Customer D m man * Max. Flown -- Min. Pressure Fire rink ier rpe nand* Max. Flow -- Min. Pressure- Svstem Tag: Multi Date=.If-1 CV" symm. Data service Connection•' 30 Spm Max. Flow•= 31.3 9PM 42 psi Inlet Pressure 1= 8414 psi Outlet Pressure-- 69 138 psi. 31.3 gpm Meter size = 1 inch 42 3' psi Service Size= 15 inch Stand Alone 1 �Li� Pressure Regulatina yahre * CVWI) USES WORST CASE CONDITION Calculations, I PZ= f 'Calve;l�a Res. # =L. 9 u Res./Ht-?2' w HGL= Property Elev.= - —"341 3 _ The meter siting li for plan chinch **For I lation Purooses-s2oft cone ,ctlan Includes: Service Connection Pipe=501, Meter Stop, Meter, Check valve & Shut Off Valve 1-"se4 • fry! Date: dfor i *""""This is lust a 0110TE. all fPPc arP a11110rt to rhannP****+**** cvwd-95p fo.... 01-I[1 SHASTA FIRE PROTECTION, INC. 72120 NORTHSHORE STREET STE. C THOUSAND PALMS, CALIFORNIA 92276 HYDRAULIC CALCULATIONS FOR: HARANG RESIDENCE ADDITION 81930 MOUNTAIN VIEW LN. LA QUINTA,CALIFORNIA DRAWING NUMBER: 3of3 DATE: 4-1-22 -DESIGN DATA - REMOTE AREA LOCATION: REMOTE ADDITION ROOM N.E. CORNER OF EXISTING RESIDENCE OCCUPANCY CLASSIFICATION: STORAGE DENSITY: 0.05 gpm/sq. ft. AREA OF APPLICATION: TWO HEAD HYD. CALC. COVERAGE PER SPRINKLER: 256 sq. ft. TYPE OF SPRINKLERS CALCULATED: RESIDENTIAL "SSP" K=4.9 NUMBER OF SPRINKLERS CALCULATED: 2 TOTAL SPKR DEMAND INCLUDING DOMESTIC DEMAND @ SOURCE: 31.4 gpm @ 49.0 psi DOMESTIC DEMAND: 5 gpm SPRINKLER DEMAND AT BASE OF RISER (HYD NODE #6): 26.4 gpm @ 35.6 psi NOTE: HYD NODE #6 IS AT DOMESTIC WATER SUPPLY INTERSECTION TO FIRE SYSTEM TYPE OF SYSTEM: WET WATER SUPPLY Source: CVWD Test Date: 10-8-2015 INFO By: BRIAN FOGG Location: "AVERAGE PSI IN THE AREA" Static: 87 psi Residual: N.A.psi Flow: N.A.gpm INSTALLING CONTRACTOR Name: SHASTA FIRE PROTECTION,INC. Address: 72120 NORTHSHORE STREET (STE. C) THOUSAND PALMS, CA. 92276 Phone:(760) 404-1350 CALIF. STATE LIC NO. 476633 NAME OF DESIGNER: JOHN PAULUS AUTHORITY HAVING JURISDICTION: CITY OF LA QUINTA FIRE PREVENTION NOTES: Calculations performed by HASS under license # 16090901, granted by HRS SYSTEMS, INC. (Notes continue after pipe calculations results.) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 4/1/2022IGN\HYD CALL\OWENS RESIDENCE HYD CALL 15-080 10-3-15.SDF JOB TITLE: HARANG RESIDENCE ADDITION HYD CALL 15-080 4-1-22 WATER SUPPLY ANALYSIS Static: 87.00 psi Resid: 70.00 psi Flow: 100.0 gpm 100.0 1 80.0 G A U G E 60.0 P R E S 40.0 S U R E ( 20.0 p s i -14.7 2 LEGEND 1 � Available pressure 85.00 psi @ 31.4 gpm 2 � Required pressure 49.02 psi @ 31.4 gpm A. Source Supply Curve B. System Demand Curve 20 30 40 50 60 70 80 90 100 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 4/l/2022IGN\HYD CALL\OWENS RESIDENCE HYD CALL 15-080 10-3-15.SDF JOB TITLE: HARANG RESIDENCE ADDITION HYD CALL 15-080 4-1-22 NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 87.0 70.0 100.0 85.0 31.4 49.0 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.4 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.4 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) SOURCE -7.0 SOURCE 49.0 31.4 2 -7.0 - - - - 46.5 - - - 3 -7.0 - - - - 41.7 - - - 4 -5.0 - - - - 39.2 - - - 5 0.5 - - - - 36.1 - - - 6 1.5 HOSE STREAM 35.6 5.0 7 10.0 - - - - 30.5 - - - 8 10.0 - - - - 30.3 - - - 9 10.0 - - - - 28.7 - - - 10 10.0 - - - - 26.7 - - - 11 10.0 - - - - 24.9 - - - 12 10.0 - - - - 22.5 - - - 13 10.0 - - - - 20.7 - - - 14 10.0 - - - - 18.5 - - - 15 10.0 - - - - 17.2 - - - 16 10.0 - - - - 9.6 - - - 17 8.5 - - - - 9.3 - - - 18 8.5 - - - - 7.8 - - - 101 8.0 K= 4.90 7.5 13.4 102 8.0 K= 4.90 7.0 13.0 NOTES SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 4/l/2022IGN\HYD CALL\OWENS RESIDENCE HYD CALL 15-080 10-3-15.SDF JOB TITLE: HARANG RESIDENCE ADDITION HYD CALL 15-080 4-1-22 NFPAS PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 Source 0.0 2.50 120 2.6 SOURCE -7.0 49.0 31.4 3 A1.000 C: 5.0 6.00 -0.0 2 -7.0 46.5 31.4 1.049 G: 1.0 8.50 0.300 2.6 Pipe: 2 0.0 0.0 80.00 150 4.8 2 -7.0 46.5 31.4 4 F1.250 2E:16.0 16.00 -0.0 3 -7.0 41.7 31.4 1.394 96.00 0.050 4.8 Pipe: 3 0.0 0.0 25.00 150 2.5 3 -7.0 41.7 31.4 5 F1.250 E: 8.0 8.00 0.9 4 -5.0 39.2 31.4 1.394 33.00 0.050 1.6 Pipe: 4 0.0 0.0 5.50 150 3.1 4 -5.0 39.2 31.4 6 L1.250 E: 3.0 3.00 2.4 5 0.5 36.1 31.4 1.265 8.50 0.080 0.7 Pipe: 5 H.S. 5.0 Disch 1.00 120 0.6 5 0.5 36.1 26.4 7 01.250 G: 1.2 1.17 0.4 6 1.5 35.6 31.4 1.425 2.17 0.067 0.1 Pipe: 6 0.0 0.0 E: 3.5 8.50 120 5.0 6 1.5 35.6 26.4 8 01.250 T: 7.0 18.70 3.7 7 10.0 30.5 26.4 1.425 C: 8.2 27.20 0.049 1.3 Pipe: 7 0.0 0.0 1.00 120 0.2 7 10.0 30.5 26.4 9 01.250 E: 3.5 3.51 -0.0 8 10.0 30.3 26.4 1.425 4.51 0.049 0.2 Pipe: 8 0.0 0.0 24.42 150 1.6 8 10.0 30.3 26.4 10 F1.250 2E:16.0 20.60 -0.0 9 10.0 28.7 26.4 1.394 2R: 4.6 45.02 0.036 1.6 Pipe: 9 0.0 0.0 38.50 150 2.0 9 10.0 28.7 26.4 11 F1.250 T: 7.3 16.50 -0.0 10 10.0 26.7 26.4 1.394 4R: 9.2 55.00 0.036 2.0 Pipe: 10 0.0 0.0 23.33 150 1.8 10 10.0 26.7 26.4 12 F1.250 3E:24.0 26.30 -0.0 11 10.0 24.9 26.4 1.394 R: 2.3 49.63 0.036 1.8 Pipe: 11 0.0 0.0 44.33 150 2.4 11 10.0 24.9 26.4 13 F1.250 2E:16.0 22.90 -0.0 12 10.0 22.5 26.4 1.394 3R: 6.9 67.23 0.036 2.4 Pipe: 12 0.0 0.0 18.67 150 1.8 12 10.0 22.5 26.4 14 F1.250 3E:24.0 30.90 -0.0 13 10.0 20.7 26.4 1.394 3R: 6.9 49.57 0.036 1.8 Pipe: 13 0.0 0.0 54.92 150 2.2 13 10.0 20.7 26.4 15 F1.250 T: 7.3 7.30 -0.0 14 10.0 18.5 26.4 1.394 62.22 0.036 2.2 Noti SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 4/1/2022IGN\HYD CALL\OWENS RESIDENCE HYD CALL 15-080 10-3-15.SDF JOB TITLE: HARANG RESIDENCE ADDITION HYD CALL 15-080 4-1-22 Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 14 0.0 0.0 2E:16.0 9.25 150 1.3 14 10.0 18.5 26.4 16 F1.250 T: 7.3 25.60 -0.0 15 10.0 17.2 26.4 1.394 R: 2.3 34.85 0.036 1.3 Pipe: 15 0.0 0.0 55.58 150 7.6 15 10.0 17.2 26.4 17 F1.000 T: 6.0 11.10 -0.0 16 10.0 9.6 26.4 1.101 3R: 5.1 66.68 0.114 7.6 Pipe: 16 0.0 0.0 1.50 150 0.3 16 10.0 9.6 26.4 18 F1.000 E: 7.0 7.00 -0.6 17 8.5 9.3 26.4 1.101 8.50 0.114 1.0 Pipe: 17 0.0 13.0 102 6.58 150 1.5 17 8.5 9.3 13.4 101 F1.000 E: 7.0 7.00 -0.0 18 8.5 7.8 26.4 1.101 13.58 0.114 1.5 Pipe: 18 4.90 13.4 Disch 2.21 150 0.3 18 8.5 7.8 0.0 F1.000 E: 7.0 13.00 -0.2 101 8.0 7.5 13.4 1.101 T: 6.0 15.21 0.032 0.5 Pipe: 19 4.90 13.0 Disch 15.04 150 0.7 18 8.5 7.8 0.0 F1.000 2E:14.0 15.70 -0.2 102 8.0 7.0 13.0 1.101 R: 1.7 30.74 0.031 0.9 NOTES (HASS): (1) Calculations were performed by the HASS 2021 D computer program in accordance with NFPA13 (2020) under license no. 64617362 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.005 gpm and a maximum imbalance at any node of 0.086 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 11.7 ft/sec at pipe 1. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node SOURCE under full flow conditions is 83.64 psi with a flow of 41.65 gpm. Noti SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 4/1/2022IGN\HYD CALL\OWENS RESIDENCE HYD CALL 15-080 10-3-15.SDF JOB TITLE: HARANG RESIDENCE ADDITION HYD CALL 15-080 4-1-22 (6) PIPE FITTINGS TABLE HASS Pipe Table Name: standard PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell -------------------------------------------------------- Tee LngEll ChkVly BfyVly GatVly AlmChk DPVly NTee F F45Ell 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 2.00 5.00 1.00 PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) F E T R K C G F45 Ell Tee RunT Kplg ChkVly Gate 1.101 1.40 7.00 6.00 1.70 1.00 8.00 0.40 1.394 1.80 8.00 7.30 2.30 1.00 11.00 0.80 PAGE: L MATERIAL: CT-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Ell Tee 45-Ell TeeRun Kouplg ChkVly GatVly NPTee 1.265 3.00 6.00 1.00 2.00 0.50 7.00 0.00 6.00 PAGE: 0 MATERIAL: Eddythread 40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyVly GatVly AlmChk DPVly NPTee 1.425 3.51 7.01 2.34 8.18 7.01 1.17 11.69 11.69 7.01 a dt Blazemaster° FIRE SPRINKLER SYSTEMS LISTED AND APPROVED FOR MORE TYPES OF APPLICATIONS THAN ANY OTHER NON-METALLIC SYSTEM • Sprinkler Contractors • General Contractors Builders & Developers • Architects & Engineers • Authorities Having Jurisdiction Lubrizol BlazeMaster hen dealing with fire protection, you need a piping system ■■ you can depend on. BlazeMaster® CPVC pipe and fittings are designed specifically for fire sprinkler systems and are based on more than 50 years of proven experience. Lubrizol, the worldwide leader in CPVC innovation, takes fire sprinkler systems to a level of superior performance that exceeds your expectations. BlazeMaster fire sprinkler systems are the most advanced, Listed and approved non-metallic piping system available on the market today. And there's no comparison between CPVC pipe and metal pipe. CPVC systems offer more advantages than metal systems making all other pipes obsolete. Check the facts: Certified by NSF International for potable water safety under all water conditions Elimination of scaling and corrosion for lasting performance, even in salt air environments Natural immunity to Microbiologically Influenced Corrosion (MIC) Superior flow characteristics offer better hydraulic design over metal systems Ease of fabrication in the field provides unmatched flexibility Minimal tool investment generates increased cost savings 50-year life expectancy CPVC formulation delivers exceptional toughness Quality Assurance Program guarantees consistency and reliability I !Ch 076 mL •". BlazeMaster fire sprinkler systems are backed by an extensive field support organization, which is available for expert technical assistance and can provide you with: Proven installation recommendations to maximize efficiency and cost savings Expert consultation regarding compliance with local, regional and national codes Assistance with architects and engineers on design and specification work There are numerous advantages to using the BlazeMaster fire sprinkler technology to address your specific needs, including: Sprinkler Contractors • Improved durability: BlazeMaster CPVC pipe and fitting compounds have been specially formulated using Lubrizol technology for improved durability. provides many advantages during installation, even at cold temperatures. • Cost savings: Overhead on tools is minimal since pipe can be cut on -site with simple hand tools. A one-step joining system makes installations even quicker, keeping labor to a minimum. General Contractors • Less conflict with other trades: Contractors installing BlazeMaster systems work easily and quickly around dry-wallers, framers and other mechanical contractors. • Lightweight: No special rigging or equipment is needed to move BlazeMaster pipe within the building. Builders and Developers L t 1 t II d ow cos. ns a e costs of a BlazeMaster system are significantly lower and prices are more stable than Optimal sized system: Smooth internal diameters lead to better hydraulic performance than metal systems, which often means pipe can be downsized, lowering material costs. �ZJb AA Listings and Approvals UL 1821 Listed • Exposed system risers NFPA 130,13R • Exposed basement NFPA 13D (solid wood joist) • Extended coverage (exposed) — 20' spacing on pendent in lieu of 15' • Use with all Tyco and Viking combustible concealed sprinklers • Tyco attic sprinkler head with wet system piping (feed main and ridge installation) • Exposed extended coverage sidewall sprinkler Listings for exposed pipe & fittings — 24' extended coverage sidewall sprinkler,12" drop,1557 sprinkler head 18' extended coverage sidewall sprinkler,12" drop,165°F sprinkler head —16' extended coverage sidewall sprinkler,12" drop,175°F sprinkler head —14' standard coverage sidewall sprinkler,12" drop, 200°F sprinkler head • Permitted for use with return air plenums with no set -back at ceiling openings per NFPA 90A ULC or CUL Listed Factory Mutual Approved • Factory Mutual Approval exposed • Factory Mutual Approval above drop -in ceilings • Factory Mutual Approval exposed w/ Soffi-Steel`a'** soffiting covering system • VdS Approval • TFRI Approval LPCB Approval NSF Certification Other Differentiation • Size available up to 3" • Approved commercial product for over 25 years • Backed by over 50 years of CPVC resin and compound manufacturing experience • CPVC resin & compound from ISO 9001 manufacturing facilities • System chemical compatibility program (ancillary products) backed by independent third party testing/verification • Formal installation training program which has more than 25,000 graduates • Leader in new Listing and Approval developments • Dedicated CPVC system field consultants • CPVC pipe compound pressure rated by Plastics Pipe Institute • CPVC fitting compound pressure rated by Plastics Pipe Institute • Pipe compound cell class, 23547, exceeds the minimum allowable ASTM requirements for CPVC tensile strength • Fitting compound cell class, 24447, exceeds the minimum allowable ASTM requirements for CPVC impact strength Refer to manufacturer's installation instructions for product Listings and limitations prior to use. ** Soffi-Steel is a registered trademark of Grice Engineering Lubrizol J11110- Lubrizol Advanced Materials, Inc. BlazeMaster® Marketing Department 9911 Brecksville Road Cleveland, OH 44141-3201 USA 216-447-5000 888-234-2436 Fax: 216-447-5313 Chaussee de Wavre, 1945 1160 Brussels Belgium 32-2-678-19-11 Fax: 32-2-678-19-90 1107-1110 Shui On Centre 6-8 Harbour Road Wan Chai, Hong Kong 852-2508-1021 Fax: 852-2512-2241 QUALITY ASSURANCE PROGRAM BlazeMaster® pipe and fittings are produced to stringent quality standards, established by Lubrizol, that exceed ASTM and other industry standards. Lubrizol has partnered with eight high quality manufacturers of pipe and fittings to bring the BlazeMaster system to market. Each manufacturer of the pipe participates in a Quality Assurance Program that ensures that these high standards are maintained for your peace of mind. This program is unique to Lubrizol and includes testing on strength and ductility and other physical properties of the pipe as well as dimensional tolerances. Lubrizol remains the technology leader and primary source of CPVC materials worldwide. While we do not manufacture pipe and fittings, we maintain a close and active relationship with the pipe and fittings manufacturers. Ask for the details of the warranty program from these BlazeMaster manufacturers. For a complete listing of regional sales representatives and manufacturers, please visit our website at www.blazemaster.com. From plumbing to siding to fire sprinkler systems and more... All the pieces have now come together to solve many of today's toughest building and industrial challenges. To contact a sales consultant, call 888.234.2436 ext. 447.7393 or visit our website at www.fbcbuildingsolutions.com. BM 002 ® is a registered trademark of The Lubrizol Corporation. TM is a trademark of The Lubrizol Corporation. The information contained herein is believed to be reliable, but no representations, guarantees or warranties of any kind are made as to its accuracy, suitability for particular applications or the results to be obtained therefrom. The information is based on laboratory work with small-scale equipment and does not necessarily indicate end product performance. Because of the variations in methods, conditions and equipment used commercially in processing these materials, no warranties or guarantees are made as to the suitability of the products for the applications disclosed. Full-scale testing and end product performance are FBC Building Solutions FlowGuard Gold® Pipe & Fittings FlowGuard® MultiPort CPVC Manifold FlowGuard® MultiPort Commercial System FlowGuard® Bendable Piping FlowGuard" Flex Tubing BlazeMaster® Fire Sprinkler Systems BlazeMaster® Multipurpose System © The Lubrizol Corporation 2010, all rights reserved. the responsibility of the user. Lubrizol Advanced Materials, Inc. shall not be liable for and the customer assumes all risk and liability of any use or handling of any material beyond Lubrizol Advanced Materials, Inc.'s direct control. THE SELLER MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Nothing contained herein is to be considered as permission, recommendation, nor as an inducement to practice any patented invention without permission of the patent owner. Printed in U.S.A. 02110 Page 1 of 6 N4 I KJ® FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Viking Freedom° Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass -bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-factor of 4.9 (70.6 metric*), allows the sprinkler's efficient use of available water supplies for the hydraulically designed fire -protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre -assembled with a threaded adapter for installation with a low -profile small -diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push -on", "thread -off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2" (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS c 0L us UL Listed (C-UL-US-EU): Category VKKW EU Refer to the Approval Charts and Design Criteria for C-UL-US-EU Listing requirements that must be followed. WARNING: Cancer and Reproductive Harm- www. P65 Warn i ngs. ca.gov 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-factor: 4.9 U.S. (70.6 metric*) Glass -bulb fluid temperature rating: to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-Cl1000 and Stainless Steel UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: Phosphor Bronze UNS-051000 Belleville Spring Sealing Assembly: Beryllium Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: High Density Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 or Stainless Steel UNS-S30400 Spring: Beryllium Nickel Solder: Eutectic Available Finishes and Temperature Ratings: Finish Brass ENT Refer to Tables 1 and 2 for complete ordering information. Suffix A JN Temperature 155 of (68 °C) 200oF (93 °C) Suffix B E Ordering Information: Refer to Tables 1 and 2. 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F_012116 20.01.02 Rev 20.1 Replaces Form No. F_012116 Rev 19.1 (Replaced cover part numbers.) Page 2 of 6 N4 I Kj® FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches the cover plate's nominal temperature rating, the cover plate detaches and releases the deflector. Continued heating of the exposed sprinkler causes the heat -sensitive liquid in the glass bulb to expand. When the temperature reaches the sprinkler's nominal temperature rating, the glass bulb shatters releasing the yoke, pip cap assembly and sealing spring. Water begins flowing through the sprinkler orifice and strikes the deflector form- ing a uniform spray pattern over a specific area of coverage, which is determined by the water supply pressure at the sprinkler, in order to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. ORDERINGTABLE 1: SPRINKLER INFORMATIONInstructions: Using the sprinkler .. part number, .. the suffix for the desired.. the suffix for the desired Temperature Rating. (3) Select a cover plate (See Table 2) Sprinkler Size 1: Finishes 2: Temperature Ratings' Base Part NPT Mx. Ambient Ceiling ag Suffix Number' Inch Description Suffix Nominal Rating Bulb Color Temperature 2 20759 1/2 Brass A 155 °F (68 °C) Red 100 °F (38 °C) B ENT5I JN 200 °F (93 °C) Green 150 °F (65 °C) E Corrosion Resistant Example: 20759AB = Sprinkler Finish: ENT 155 °F (68 °C) Temperature Rated Sprinkler with a standard Brass finish. Accessories Sprinkler Wrenches and tools: A. Heavy Duty Part Number: 14047W/B3 (available since 2006) B. Head Cabinet Wrench Part Number: 140313A (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part Number: 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) Sprinkler Cabinet: Holds up to 6 sprinklers: Part number 01731A (available since 1971). Footnotes I Part number shown is the base part number. For complete part number, refer to the current Viking price list schedule. z. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. s. Requires a ''/2" ratchet (not available from Viking). 4. Also optional for removal of the protective cap. Ideal for sprinkler cabinets. 5- cULus Listed as corrosion resistant. 6. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. 7 The sprinkler temperature rating is stamped on the deflector. Form No. F_012116 20.01.02 Rev 20.1 Page 3 of 6 N4 I Kj® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com COVERTABLE 2: Instructions: Using the .. the suffix ORDERING cover for the INFORMATION plate base part number, desired Finish Cover .. the suffix for the required 1: Finishes Cover Plate Nominal Rating. 2: Temperature Rating Matrix Plate Size Style Cover Plate Sprinkler Sprinkler Max. Base Part Inch (mm) Description Suffix' Nominal Rating Nominal Ambient Ceiling Suffix Number (Required) Rating' Temperature3 23190 2-3/4(70) Round Polished Chrome F 135 °F (57 °C) 155 °F (68 °C) 100 °F (38 °C) A 23174 3-5/16 (84) Round Brushed Chrome F-/B 165 °F (74 °C) 200 °F (93 °C) 150 °F (65 °C) C 23179 13-5/16 (84) Square Bright Brass B Example: 23190MA/W = 135 °F (57 °C) Temperature Rated, 2-3/4" (70 mm) 23193' 12-3/4 (70) SST Round Antique Brass B-/A 231835 3-5/16 (84) SST Round Brushed Brass B-/B Brushed Copper E-/B Painted White M-/W Diameter, Round Cover Plate with a Painted White finish. M-/I Painted Ivory M-/B Painted Black Footnotes 1. Part number shown is the base part number. For complete part number, refer to the current Viking price list schedule. z. The sprinkler temperature rating is stamped on the deflector. I Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 4. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. 5. Stainless Steel versions are not available with any finishes or paint. Form No. F_012116 20.01.02 Rev 20.1 Page 4 of 6 ® FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart Viking VK494, 4.9 K-factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the Design Criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D Sprinkler Base NPT Thread Size Nominal K-factor Maximum Water Part Number 1 SIN Working Pressure Inches mm U.S. metric 2 20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar) Max. Coverage Flow Pressure Listings and Minimum Area 6 GPM (LPM) PSI(bar) Deflector to Installation Approvals3,6 Spacing Ceiling Type Ft. 155 °F (68 °C), 200 °F (93 °C) c 0 4 us Ft. X Ft. (m) (m X m) Temperature Rated Sprinklers eu 12 X 12 13 7.0 (3.7 X 3.7) (49.2) (0.48) 14 X 14 13 7.0 (4.3 X 4.3) (49.2) (0.48) Refer to Figure 2 Concealed with Cover Plate See Footnotes 8, & 9 8 16 X 16 13 7.0 (4.9 X 4.9) (49.2) (0.48) Assembly. See Footnote 7. (2.4) 18 X 18 17 12.0 (5.5 X 5.5) (64.4) (0.83) 20 X 20 20 16.7 (6.1 X 6.1) (75.7) (1.15) Footnotes Part number shown is the base part number. For complete part number, refer to the current Viking price schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. a Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union. 6. Meets New York City requirements, effective July 1, 2008. e. For areas of coverage smaller than shown, use the "Flow' and "Pressure" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow" and "Pressure' used. 7 Other paint colors are available on request with the same listings as the standard finish colors. Stainless Steel cover plates are not available with any finishes or paint. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. s. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black'. s. C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) Form No. F_012116 20.01.02 Rev 20.1 Page 5 of 6 N4 I Kj® FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA (Also refer to the Approval Chart.) AL UL Listing Requirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area" in accordance with sections 9.5.2.1 or 10.2.4.1.2 of the current edition of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT. Always refer to Bulletin Form No. F 080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly 2-1/4" (57 mm) • Protective cap removed diameter opening • Use wrench 14047W/B** required in the ceiling. Sprinkler Wrench - Part No. 14047W/B** Step 1: Step 2: 1 1 Carefully slide the Carefully press the wrench upward and wrench sideways around turn slightly to ensure engagement with the deflector and pins the sprinkler wrench flats. Sprinkler wrench flat NEVER install the sprinkler by applying the installation Sprinkler wrench across the frame arms. DO NOT overtighten. frame arms Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Figure 1: Sprinkler Installation and Proper Wrench Usage ink A 1/2" ratchet is required (Not available from Viking) Form No. F_012116 20.01.02 Rev 20.1 Page 6 of 6 ® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1/2" (15 mm) NPT 2-9/16' Ma) C4 -- NOTE: Upon sprinkler activation, the deflector descends to approximately 13116" (21 mm) below the sprinkler body. -1/16" (52 mm) Minimum Figure 2: Sprinkler Dimensions and Cover Installation Q\'\('p C US TO �A O n U� O �y �O All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 3: Identification of Custom Paint for Concealed Covers 2-3/4" (70 mm) or 3-5/16" (84 mm) 3-5/16" (84 mm) Figure 4: Square Cover Assembly 23179 Form No. F_012116 20.01.02 Rev 20.1 Replaces Form No. F_012116 Rev 19.1 (Replaced cover part numbers.) CAL FIRE - RIVERSIDE UNIT RIVERSIDE COUNTY FIRE DEPARTMENT OFFICE OF THE FIRE MARSHAL — LA QUINTA CALIFORNIA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org May 7, 2022 Shasta Fire Protection 72120 Northshore Street #C Thousand Palms, CA 92276 Re: Residential Fire Sprinkler Plan Review — HARING RESIDENCE ADDITION FSS2022-0119 / 81930 MOUNTAIN VIEW LANE, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD ai�Cv uGKCv THIS CARD IS TO REMAIN ON SITE AT ALL TIMES.—CALIFORNIA INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 81930 MOUNTAIN VIEW LANE PERMIT#: FSS2022-0119 AT ED: 5/7/2022 DESCRIPTION: HARING RESIDENCE ADDITION CONTRACTOR: SHASTA FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre -pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final IF Deluge/pre-action SPRINKLER U.G. Final EF Thrust block pre -pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final IF Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors' test Hood/duct extinguishing High pile storage High pile rack storage In -rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final IF Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final e F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final e F FIRE ALARM KNOX SYSTEM Rough -wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final F' Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE- 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE -INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131