FSS2022-0168ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT SYMONS FIRE PROTECTION INC 9475 Chesapeake Drive san diego CA 92123 (619)588-6364 angela@symonsfp.com CONTRACTOR SYMONS FIRE PROTECTION INC 9475 Chesapeake Drive san diego CA 92123 (619)588-6364 angela@symonsfp.com OWNER SUNRISE LQ 300 EAGLE DANCE CIR PALM DESERT CA 92211 (619)588-6364 nsparks@rancholaquin ta.com CONDITIONS Description: ANDALUSIA / FIRE SPRINKLER / BRES2021-0210 / PLAN 401 Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - TRACT HOMES Status: ISSUED Applied: 4/12/2022 ECON Parcel No: 764200071 Site Address: 59125 MARBELLA LA QUINTA,CA 92253 Approved: 4/13/2022 AHI Subdivision: TR 37790 Block: Lot: 32 Issued: ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $4,000.00 Occupancy Type: Construction Type: Expired: 11/5/2022 KHET No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: fire sprinklers for lot 50032 FINANCIAL INFORMATION Printed: Friday, April 07, 2023 8:26:45 AM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0168 BOND INFORMATION INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 5/9/2022 5/9/2022 APPROVED SEE NOTES FCMP revised plans and calcs required prior to final OVERHEAD HYRO KHET 5/9/2022 5/9/2022 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH – ETRAKIT (1 DAY) PERMIT TECH BUCKET 4/12/2022 4/13/2022 4/13/2022 COMPLETE PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $167.00 $167.00 4/14/22 WEB11408 636610939 25 CREDIT 682025 ECON Total Paid for FIRE FEES: $167.00 $167.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 4/14/22 WEB11408 636610939 25 CREDIT 682025 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 4/14/22 WEB11408 636610939 25 CREDIT 682025 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$183.00 $183.00 Printed: Friday, April 07, 2023 8:26:45 AM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0168 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 4/12/2022 Etrakit Contractor ANDALUSIA 401 LOT 50032.pdf 1 DOC 5/9/2022 KOHL HETRICK Pages from ANDALUSIA PLAN 401 - 5-9-2022 - Insp Notes.pdf Pages from ANDALUSIA PLAN 401 - 5-9-2022 - Insp Notes.pdf 1 Printed: Friday, April 07, 2023 8:26:45 AM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0168 SNEWA 10% REDUCTION WAS TAKEN OFF FORCALC PURPOSES. STATIC PRESSURE ISCALCULATED AT 86.4 PSI PER COACHELLAWATER DISTRICT. RESIDUAL SYSTEM WASCALCULATED WITH 72.0 PSI.ALL COMPARTMENTS WITH ONE HEAD WILL BE BASEDON 20FT SPACING. ALL OTHER ROOMS ARE BASED ON15x15 FT SPACING.CALCULATIONS ARE BASED ON THE WORSTCASE SCENARIO TWO HEADCALC ON 15 FT SPACING2Residential AREA 3 0.10gpm/ft² for 283ft²Residential AREA 2 0.10gpm/ft² for 85ft²GFIGFIref.17 sqftNO A/S17 sqftNO A/S17 sqftNO A/S41 sqftNO A/S17 sqftNO A/S17 sqftNO A/S7 sqftNO A/S12 sqftNO A/S53 sqftNO A/S12 sqftNO A/S14 sqft NO A/S12 sqft NO A/S10 sqftNO A/S10 sqftNO A/SPWDRPORCHGREAT ROOMENTRYPORTICOPWDRCOURTYARDLAUNGALLERYHALLGARAGE2 CARGARAGE1 CARCASITABEDROOM 4BATH 4BEDROOM 2BATH 2BEDROOM 3BATH 3KITCHENBARWETPORCHDININGBATHMASTERBEDROOMMASTERPORCHPORCHWDCLOSETWALK-INCLOSETWALK-INPANTRYHEAT ZONEFPPWDRPWDRHALLHEAT ZONEPWDRACCESSATTICPWDRCL.CL.16' CLG13' CLG13' CLG13' CLG13' CLG13' CLG10' CLGCL.CL.WHFAUACCESSATTIC8' CLGTO 3/4" CPVCT.O.R.OPT. KITCHENETTE32171" RISER IN WALL W/ INT.LABELED ACCESS PANEL2012'-7 -DN31420413721422513Residentia AREA 1 0.10gpm/ft² for 148ft²10'-09'-1½8'-9½8'-1½6'-15'-63'-10½7'-23'-8½5'-7½2'-39'-69'-65'-25'-8½6'-2½2'-65'-8½4'-6½10'-06'-39'-0½3'-012'-97'-33'-07'-6 7'-67'-2½3'-93'-2½ 4'-8½10'-010'-07'-615'-05'-10½7'-612'-4½13'-7½7'-66'-11½4'-9½2'-6 2'-64'-14'-12'-14'-1½6'-011'-8½3'-1½6'-011'-8½6'-06'-011'-8½6'-011'-9 11'-95'-0½5'-0½10'-010'-04'-11½12'-11½1'-113'-610'-12'-6 2'-67'-0½7'-02'-03'-0 -UP3'-0 -UP3'-0 -DN317320574'-015'-54'-05'-011'-2½ 11'-2½5'-07'-614'-6 13'-06'-117'-59'-107'-57'-614'-2½7'-67'-68'-612'-2½6'-16'-1½11'-10½7'-67'-611'-10½4'-6½4'-6½TRANSITION6'-0 -UP6'-0 -DNAF1AF1 Hydraulic Information Remote Area 1OCCUPANCY CLASSIFICATIONResidentia AREA 1 DENSITY (gpm/ft²)0.10 for 900ft² (Actual 148ft²)TOTAL HOSE STREAMS5.00TOTAL HEADS FLOWING1K-FACTOR4.3TOTAL WATER REQUIRED26.00TOTAL PRESSURE REQUIRED76.079BASE of RISER (gpm)21.00BASE of RISER (psi)54.329SAFETY MARGIN (psi)+10.285 (11.9%) Hydraulic Information Remote Area 3OCCUPANCY CLASSIFICATIONResidential AREA 3 DENSITY (gpm/ft²)0.10 for 900ft² (Actual 283ft²)TOTAL HOSE STREAMS5.00TOTAL HEADS FLOWING2K-FACTOR4.3TOTAL WATER REQUIRED29.02TOTAL PRESSURE REQUIRED56.664BASE of RISER (gpm)24.02BASE of RISER (psi)33.568SAFETY MARGIN (psi)+29.692 (34.4%) Hydraulic Information Remote Area 2OCCUPANCY CLASSIFICATIONResidential AREA 2 DENSITY (gpm/ft²)0.10 for 900ft² (Actual 85ft²)TOTAL HOSE STREAMS5.00TOTAL HEADS FLOWING2K-FACTOR4.3TOTAL WATER REQUIRED29.01TOTAL PRESSURE REQUIRED76.800BASE of RISER (gpm)24.01BASE of RISER (psi)53.709SAFETY MARGIN (psi)+9.555 (11.1%)60 DN60 UPPWDRBATH 3HALLLAUNDRYPORTICOBEDROOM 4SLABT.P.T.O. WDW3123124412 12SLABT.P.T.P.SECTIONA11110'-016'-0NVICINITY MAPN.T.S. 8" MAINCOMBINED PLUMBING &SPRINKLER SHUT OFF(OPTIONAL)3/4" WATER METER EL= -3' TRANSITION FROM COPPERTO PVC120FT OF 2" PVC PIPE14 5'FT OF 1" COPPER(SWEEP) B.O.R. EL= 1' EL= -8'2UNDERGROUND DETAILN.T.S.2173 1" PVC½" DRAIN 1" PVC 1" CHECK VALVE5TRANSITION FROMCOPPER TO PVC PLUMBING SHUT OFF DOMESTIC PLUMBINGREGULATOR3/4" CPVCWATER GAUGE225TRANSITION EL= -5' EL= -5'LATERAL20 FT OF 1" COPTRANSITION1" COPPER (SWEEP)5 GPM TO DOMESTIC PLUMBING UNDERGROUND NOTES:1. ALL LOTS TO HAVE 3/4" WATER METERS.2. ALL LOTS TO HAVE 2" (SCHEDULE 40) PVC PIPE FROM WATER METER TO HOUSE.3. NO ELEVATION ON ANY LOT TO EXCEED 5'FT IN ELEVATION CHANGE FROM METER TO HOUSE.4. NO LOT TO EXCEED 20'FT FROM 8" MAIN TO 3/4" WATER METER.5. NO LOT TO EXCEED 120'FT OF 2"PVC FROM 3/4" WATER METER TO HOUSE.6. ALL FIRE SPRINKLER RISERS LOCATED IN GARAGE.7. ALL 3/4" WATER METERS WILL BE LOCATED AT PROPERTY LINE OF EACH HOUSE.Sprinkler LegendSymbolManufacturerSINModelQuantityK-FactorTypeSizeResponseFinishTemperatureReliableRA0612RFC4335 4.3Pendent½QuickWhite165°FReliableR3511F1Res3093Pendent½QuickWhite175°FTotal = 44HANGER LOCATIONS ARE TO BEPLACED PER MANUFACTURERESSPECIFICATIONSSPACINGMAX. HANGERCPVC PIPING APPLICATIONSIZESPIPEFIGURE 23 - CPVC HANGERCPVC DOUBLE FASTENER STRAP TYPE HANGERHARDENED HEX HEAD SELF THREADING SCREWIS FURNISHED WITH THE HANGER AND IS THEMINIMUM FASTENER SIZE ACCEPTABLEFIGURE 22 - CPVC HANGERCPVC SINGLE FASTENER STRAP TYPE HANGERMINIMUM FASTENER SIZE ACCEPTABLEIS FURNISHED WITH THE HANGER AND IS THEHARDENED HEX HEAD SELF THREADING SCREWFIGURE 24 - CPVC HANGERCPVC DOUBLE FASTENER STRAP TYPE HANGERMINIMUM FASTENER SIZE ACCEPTABLEIS FURNISHED WITH THE HANGER AND IS THEHARDENED HEX HEAD SELF THREADING SCREW3/4"5' 6"1"6' 0"ALL ¾" CPVC PIPINGALL 10'-0" FLAT CLG'SU.N.O.REPRESENTS SOFFITREPRESENTSLINE OF CEILING CHANGESCALE: 3/16"=1'-0"FIRE SPRINKLER & PIPING PLANTHE RECIPIENT OF THESE PLANS HEREBY ACKNOWLEDGES THAT ALL PLANS, DETAILS, SPECIFICATIONS AND/OR METHODS OF INSTALLATION CONTAINED IN THIS SET OF DRAWINGS IS THE SOLE PROPERTY OF SYMONS FIRE PROTECTION, INC., AND THAT ANY USE OF THIS SET OF DRAWINGS IS PROHIBITED AND IS A VIOLATION OF COPYRIGHT LAWS WITHOUT FIRST RECEIVING PERMISSION FROM SYMONS FIRE PROTECTION, INC.THE RECIPIENT OF THESE PLANS HEREBY ACKNOWLEDGES THAT ALL PLANS, DETAILS, SPECIFICATIONS AND/OR METHODS OF INSTALLATION CONTAINED IN THIS SET OF DRAWINGS IS THE SOLE PROPERTY OF SYMONS FIRE PROTECTION, INC., AND THAT ANY USE OF THIS SET OF DRAWINGS IS PROHIBITED AND IS A VIOLATION OF COPYRIGHT LAWS WITHOUT FIRST RECEIVING PERMISSION FROM SYMONS FIRE PROTECTION, INC.EFSHEETROTTD DESERT DEVELOPMENTOFANDALUSIA PLAN 401DRAWING TITLEODATE :OCAYIMREVISIONSTDATENACRR682025EXP. DATESO12. 31. 22NE21-0642SCALE-PHONETCI-F-SIR(760) 564-2122PP-MARBELLA LOT 32LA QUINTA, CA 92253ONOTSE9475 CHESAPEAKE DR, SAN DIEGO, CA 92123 * (619) 588-6364 *FAX (619) 588-6805 *www.symonsfp.com/ * CA LIC. #682025 *IROTHE RECIPIENT OF THESE PLANS HEREBY ACKNOWLEDGES THAT ALL PLANS, DETAILS, SPECIFICATIONS AND/OR METHODS OF INSTALLATION CONTAINED IN THIS SET OF DRAWINGS IS THE SOLE PROPERTY OF SYMONS FIRE PROTECTION, INC., AND THAT ANY USE OF THIS SET OF DRAWINGS IS PROHIBITED AND IS A VIOLATION OF COPYRIGHT LAWS WITHOUT FIRST RECEIVING PERMISSION FROM SYMONSRNOEDESCRIPTIONJOBELNC16/C10NTCPROJECT:DAS NOTEDEMARKBYDRAWN BY: DEREK POWELLFIRE SPRINKLERS PLANRASTIAUTHORITY HAVING JURISDICTIONECTAF9-07-2021LA QUINTA FIRE DEPARTMENTT-CL,CNCONTRACT WITH:.IIIF1 OF F1GENERAL NOTESRESIDUAL PSI AT SOURCESTATIC PSI:53.709 10. MAINTENANCE BOOK & 1 HEAD (UP TO 3 OF EACH IF REQUIRED) OF EACH TYPE USEDOF THE FIREWALL.76.079SPRINKLER FLOW REQ. @ 8. DRILLING OR NOTCHING OF STRUCTURAL MEMBERS SHALL BE IN STRICT29.01(SIN) # RA06121HD = 15. SMOKE DETECTORS ARE TO BE INSTALLED IN ACCORDANCE WITH NFPA 72, RESIDUAL PSI AT SOURCE4. STORAGE IN ATTIC & CRAWL SPACES NOT ALLOWED WHERE NOT PROTECTED.DESIGN SPRINKLER = SYSTEM FLOW REQUIREMENTS: REMOTE AREA 114. CONTRACTOR/OWNER IS RESPONSIBLE FOR INSTALLATION OF UNDERGROUND.GPM FLOWING W/13. EXTERIOR EXPOSED STEEL PIPING PAINTED.(BY OTHERS)4.3 K-FACTOR 3. PROVIDE ELECTRICAL BELL FOR LOCAL ALARM. WIRING BY OTHERS. FLOWS PER HEAD = 9. ALL PENETREATIONS THROUGH FIREWALLS & CEILINGS BETWEEN ATTACHED GARAGE SPRINKLER FLOW REQ. @ACCORDANCE WITH CBC & CRC - (2016) 5. GARAGE & MECHANICAL ROOMS TO BE SPRINKLERED W/175* HEADS2HD = 76.800COACHELLA VALLEY WATER26.0021.0 GPM @ 23.8 PSI4.3 K-FACTOR1HD = REPLACED WITH A NEW LISTED SPRINKLER PER NFPA 13D STANDARDS. & RESIDENCE WILL BE SEALED IN AN APPROVED MANNER TO MAINTAIN INTEGRITYGPM FLOWING W/NEXT TO RISER. 2HD = 6. SPRINKLER HEADS OMITTED FROM BATHROOMS DUE TO NON-COMBUSTIBLEPHONE #:21.00CONTACT: 7. = INDICATES CALC. REFERENCE POINT.TO THE STANDARDS OF NFPA 13D 2016 EDITION.FIXTURES AND NOT EXCEEDING 55 SQ. FT.15' SPACINGSIZE AND LOCATION ON PLANS. (NOT REQUIRED PER LA QUINTA FIRE DEPT.)REL. RFC43 CONCL. FLAT 1. THIS IS A WET PIPE SPRINKLER SYSTEM DESIGNED & INSTALLED PER 313.3 AND/OR7' 6" MAX OFF WALL20' SPACING96.0 PSIINSTRUCTIONS OF THE PIPE MANUFACTURE.SYSTEM FLOW REQUIREMENTS: REMOTE AREA 2RESIDUAL PSI AT BASE OF RISERNATIONAL FIRE CODE (AND TO BE INSTALLED BY OTHERS.)(CHECK WITH SYMONS FIRE PROTECTION FOR PROPER SIZING.)GPM FLOWING W/DATE OBTAINED: 2. ALL PIPE AND FITTINGS ARE NEW, UL LISTED, AND CONFORMGPM FLOWING W/PLUS HEAD WRENCH SHALL BE PROVIDED IN SPARE HEAD CABINET LOCATED24.0110' MAX OFF WALL 11. PIPE HANGERS SHALL BE IN ACCORDANCE WITH NFPA 13D & THE WRITTEN54.329RUBEN MONTIEL12. ANY SPRINKLERS THAT HAVE BEEN PAINTED OUTSIDE OF THE FACTORY SHALL BERESIDUAL PSI AT BASE OF RISERREL. RFC43 CONCL. FLAT(SIN) # RA0612WATER FLOW INFO BY:DESIGN SPRINKLER = FLOWS PER HEAD =12.0 GPM @ 7.8 PSI6-28-21N.F.P.A. PAMPHLET #13-D (2016 EDITION) AND THE LA QUINTA FIRE DEPT.(760) 398-2661SECTION 'A'SCALE 1/4" = 1'-0"SITE PLANSCALE 1" = 200'-0"RESIDUAL PSI AT SOURCE1HD = GPM FLOWING W/29.0224.021HD = 33.568GPM FLOWING W/56.664RESIDUAL PSI AT BASE OF RISERSYSTEM FLOW REQUIREMENTS: REMOTE AREA 3REL. F1RES SEMI REC.7' 6" MAX OFF WALLSPRINKLER FLOW REQ. @12.0 GPM @ 16.0 PSIFLOWS PER HEAD =DESIGN SPRINKLER = (SIN) # R35113.0 K-FACTOR15' SPACINGSPRINKLER SYSTEM DESIGN CRITERIA & FLOW REQUIREMENTS.AREA OF WORKAPPROVEDRiverside County Fire DepartmentLa Quinta Office of the Fire MarshalBy:FIRE SAFETY SPECIALIST09/27/2021 2:11:05 PMThe approval of plans and specifications does notpermit the violation, deletion, omission or faultyinstallation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remainaccessible and exposed for inspection purposesuntil approved by the Fire Department.PERMIT # -FCMP2021-0025KITCHEN13' CLG9'-109'-10Ceiling cloud dropKohl HetrickReason: I am approving this documentContact Info: 760-409-5109Date: 2021.09.27 14:11:43-07'00'