FSS2022-0182ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT Frank Capirchio 2445 West 237 place Torrance Ca 90501 CA 90501 (310)953-5597 cap777_3@msn.com CONTRACTOR CITYCO FIRE PROTECTION 2445 WEST 237 PLACE TORRANCE CA 90501 (310)953-5597 1CITYCO@GMAIL.COM OWNER bella trust 633 via linda thousand oaks ca 91320 (310)953-5597 CONDITIONS Description: BELLA / FIRE SPRINKLER Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: ISSUED Applied: 4/22/2022 EPRS Parcel No: 776330007 Site Address: 50690 BREVA ST LA QUINTA,CA 92253 Approved: 7/12/2022 KHET Subdivision: TR 32068 Block: Lot: 7 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $1,200.00 Occupancy Type: Construction Type: Expired: 5/14/2023 KHET No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE PLAN REVISION SUBMITTALS 101-0000-42420 0 $167.00 $0.00 Printed: Friday, April 07, 2023 8:50:57 AM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0182 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD HYRO KHET 10/26/2022 10/26/2022 APPROVED OVERHEAD ROUGH PIPING KHET 10/26/2022 10/26/2022 DISAPPROVE D SEE ATTACHMENTS Reinspection required to observe corrections affected by clearance from HVAC, Smokies and Ceiling Fixtures - as well as appropriate insulation protection of CPVC from contact with jacketed electrical wiring. **Revised plans and calcs will also be required prior to final. OVERHEAD ROUGH PIPING KHET 11/15/2022 11/15/2022 APPROVED PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $250.00 $250.00 7/27/22 R71427 2000 CHECK CITYCO FIRE PROTECTION AHI FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $250.00 $250.00 7/27/22 R71427 2000 CHECK CITYCO FIRE PROTECTION AHI Total Paid for FIRE FEES: $667.00 $500.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 7/27/22 R71427 2000 CHECK CITYCO FIRE PROTECTION AHI Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 7/27/22 R71427 2000 CHECK CITYCO FIRE PROTECTION AHI Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$683.00 $516.00 Printed: Friday, April 07, 2023 8:50:57 AM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0182 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 8/8/2022 Etrakit Contractor 50-690 BrevaASBlt.pdf 1 DOC 8/8/2022 Etrakit Contractor CALCS 690 CASITA.pdf 1 DOC 4/22/2022 Etrakit Public Registration new fire sprinklers 50-690 Breva.pdf 1 DOC 4/22/2022 Etrakit Public Registration calcs CALCS (15).pdf 1 DOC 7/12/2022 KOHL HETRICK FSS2022-0182 - APPROVED PLANS AND CALCS.pdf FSS2022-0182 - APPROVED PLANS AND CALCS.pdf 1 DOC 7/12/2022 KOHL HETRICK FSS2022-0182 - COA AND JOB CARD.pdf FSS2022-0182 - COA AND JOB CARD.pdf 1 DOC 9/7/2022 KOHL HETRICK FSS2022-0182 - REV 1 - APPROVED PLANS AND CALCS.pdf FSS2022-0182 - REV 1 - APPROVED PLANS AND CALCS.pdf 1 DOC 10/26/2022 KOHL HETRICK FSS2022-0182 - 10-26- 2022 - INSP NOTES.pdf FSS2022-0182 - 10-26- 2022 - INSP NOTES.pdf 1 BOND INFORMATION REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH – ETRAKIT (1 DAY) AARON HICKSON 4/22/2022 4/25/2022 4/26/2022 PENDING DOCUMENTS 1ST FIRE - ETRAKIT (2 WK) KOHL HETRICK 6/17/2022 6/20/2022 7/12/2022 APPROVED SEE ATTACHMENTS Review voided by AHI. REVIEW HAS BEEN REINSTATED 2ND FIRE (1 WK)KOHL HETRICK 8/8/2022 8/15/2022 9/7/2022 APPROVED REVISED PLANS/CALCS removing waterflow switch and casita is now supplied by tie-in to main house and not a separate riser at casita. Printed: Friday, April 07, 2023 8:50:57 AM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0182 COATW/HSEAT w.i.c.bath 3SEAT LINEN JJJJJJFFFFFJFJFFFFFJFFJFFFFFFFFFFFFFFFJFJ1-car / golf cartgaragekitchendiningroomgreat roommasterbedroommasterbathbedroom 2entry / foyerw.i.c.w.i.c.courtyard2-car garagelaundrybath 2next genbathnext gensuitenext genloungebedroom 4bath 4pwdrw.i.c.mech.Cgallery hallhallbedroom 3covered patiocovered patioJdiningroomcasitasbathclo.barpizzaovencovered patiocovered patioDATE REVISIONS DESCRIPTION AS NOTEDFS-201-12-228/8/22AS BUILT DATEREVISIONSDESCRIPTIONAS NOTEDFS-101-12-228/8/22AS BUILTAPPROVEDRiverside County Fire DepartmentLa Quinta Office of the Fire MarshalBy:FIRE SAFETY SPECIALIST09/07/2022 4:42:53 PMThe approval of plans and specifications does notpermit the violation, deletion, omission or faultyinstallation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remainaccessible and exposed for inspection purposesuntil approved by the Fire Department.PERMIT # -FSS2022-0182 - REV 1Kohl HetrickReason: I am approving this documentContact Info: 760-409-5109 COATW/HSEAT w.i.c.bath 3SEAT LINEN JJJJJJFFFFFJFJFFFFFJFFJFFFFFFFFFFFFFFFJFJ1-car / golf cartgaragekitchendiningroomgreat roommasterbedroommasterbathbedroom 2entry / foyerw.i.c.w.i.c.courtyard2-car garagelaundrybath 2next genbathnext gensuitenext genloungebedroom 4bath 4pwdrw.i.c.mech.Cgallery hallhallbedroom 3covered patiocovered patioJdiningroomcasitasbathclo.barpizzaovencovered patiocovered patioDATE REVISIONS DESCRIPTION AS NOTEDFS-201-12-228/8/22AS BUILT DATE REVISIONS DESCRIPTION AS NOTEDFS-301-12-228/8/22AS BUILT Job Name :SINGLE FAMILY RESIDENCE Building :CASITA Location :50-690 BREVA ST. System : Contract : Data File :50-690 Breva CASITAASB.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 1 SINGLE FAMILY RESIDENCE Date 08/08/22 HYDRAULIC DESIGN INFORMATION SHEET Name - Date - Location - 50-690 BREVA ST. Building - CASITA System No. - Contractor - Contract No. - Calculated By - Drawing No. - Construction: ( ) Combustible ( ) Non-Combustible Ceiling Height OCCUPANCY - S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( ) S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - 5 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make Model I Elevation at Highest Outlet - Feet Size K-Factor 4.9 G Note: Temperature Rating N Calculation Gpm Required 31.6 Psi Required 48.7 At Test Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 90.6 Elev. R Residual (Psi) - 70.2 Other Well Flow (Gpm) - 2900 Proof Flow Gpm S Elevation - -3 P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 2 SINGLE FAMILY RESIDENCE Date 08/08/22 10 20 30 40 E 50 R 60 U 70 S 80 S 90 E 100 R 110 P 120 130 140 150 300600 900 1200 1500 1800 2100 2400 2700 FLOW ( N ^ 1.85 ) City Water Supply:Demand: C1 C2 C1 - Static Pressure :90.6 C2 - Residual Pressure:70.2 C2 - Residual Flow :2900 D1 - Elevation : 6.063 D2 - System Flow :31.584 D2 - System Pressure : 78.724 Hose ( Demand ):_______D3 - System Demand :31.584 Safety Margin : 11.871 D1 D2 Water Supply Curve C Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 3 SINGLE FAMILY RESIDENCE Date 08/08/22 Fitting Legend Abbrev.Name ½¾1 1¼1½2 2½3 3½4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 1 1 1 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 N *CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O *CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R *CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used Summary Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 4 SINGLE FAMILY RESIDENCE Date 08/08/22 Node Elevation K-Fact Pt Pn Flow Density Area Press No.Actual Actual Req. 1 11.0 4.9 7.1 na 13.06 0.051 256 7.0 2 11.0 4.9 7.62 na 13.53 0.051 256 7.0 10 11.0 9.26 na 11 11.0 11.54 na 12 11.0 15.25 na 13 11.0 17.53 na 14 11.0 24.46 na 3 11.0 35.29 na 4 11.0 43.35 na TR 11.0 45.89 na BR -2.0 56.01 na 5.0 M -2.0 63.74 na TEST -3.0 78.72 na The maximum velocity is 12.28 and it occurs in the pipe between nodes BR and M Pressure / Flow Summary - STANDARD Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 5 SINGLE FAMILY RESIDENCE Date 08/08/22 Hyd.Qa Dia.Fitting Pipe Pt Pt Ref."C"or Ftng's Pe Pv *******Notes ****** Point Qt Pf/Ft Eqv.Ln.Total Pf Pn 1 13.06 1.101 N 7.0 9.900 7.100 K Factor = 4.90 to 150.0 0.0 7.000 0.0 2 13.06 0.0309 0.0 16.900 0.522 Vel = 4.40 2 13.52 1.101 R 1.0 6.200 7.622 K Factor = 4.90 to 150.0 N 7.0 8.000 0.0 10 26.58 0.1152 0.0 14.200 1.636 Vel = 8.96 10 0.0 1.055 E 3.107 13.000 9.258 to 150.0 0.0 3.107 0.0 11 26.58 0.1418 0.0 16.107 2.284 Vel = 9.76 11 0.0 1.025 E 2.7 20.000 11.542 to 150.0 0.0 2.700 0.0 12 26.58 0.1632 0.0 22.700 3.704 Vel = 10.33 12 0.0 1.055 E 3.107 13.000 15.246 to 150.0 0.0 3.107 0.0 13 26.58 0.1418 0.0 16.107 2.284 Vel = 9.76 13 0.0 1.101 N 7.0 37.200 17.530 to 150.0 3O 15.0 23.000 0.0 14 26.58 0.1152 R 1.0 60.200 6.934 Vel = 8.96 14 0.0 1.101 2O 10.0 70.000 24.464 to 150.0 14R 14.0 24.000 0.0 3 26.58 0.1152 0.0 94.000 10.828 Vel = 8.96 3 0.0 1.101 N 7.0 50.000 35.292 to 150.0 O 5.0 20.000 0.0 4 26.58 0.1152 8R 8.0 70.000 8.062 Vel = 8.96 4 0.0 1.101 N 7.0 14.000 43.354 to 150.0 R 1.0 8.000 0.0 TR 26.58 0.1152 0.0 22.000 2.535 Vel = 8.96 TR 0.0 1.055 E 3.107 13.000 45.889 to 150.0 S 7.768 18.643 5.630 BR 26.58 0.1418 T 7.768 31.643 4.487 Vel = 9.76 BR 5.00 1.025 T 6.75 25.000 56.006 Qa = 5.00 to 150.0 E 2.7 9.450 0.0 M 31.58 0.2245 0.0 34.450 7.733 Vel = 12.28 M 0.0 1.025 G 1.35 30.000 63.739 to 150.0 T 6.75 8.100 6.433 * * Fixed Loss = 6 TEST 31.58 0.2245 0.0 38.100 8.552 Vel = 12.28 0.0 31.58 78.724 K Factor = 3.56 Final Calculations - Hazen-Williams Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org July 12, 2022 CityCo Fire Protection 2445 West 237 Place Torrance, CA 90501 Re: Residential Fire Sprinkler Plan Review – BELLA TRUST – LOT 7 FSS2022-0182 / 50690 BREVA, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 50690 BREVA PERMIT#: FSS2022-0182 DATE ISSUED: 7/12/2022 DESCRIPTION: BREVA TRUST – LOT 7 CONTRACTOR: CITYCO FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible dur ing the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.