Loading...
LAQ-14-RS-031 Belmont Plan 4ADDITIONAL SITES CHRONOLOGY CONTACTS CONDITIONS Description: 3,475SF DWELLING/VB/RES-3/CLASS A-FR/13D Type: BUILDING, RESIDENTIAL Subtype: DWELLING - SINGLE FAMILY DETACHED Status: FINALED Applied: 12/18/2013 Parcel No: 767320999 Site Address: 81305 STORM CAT CT LA QUINTA,CA 92253 Approved: 3/3/2014 Subdivision: Block: Lot: Issued: Lot Sq Ft: Building Sq Ft: Zoning: Finaled: 8/21/2014 KKI Valuation: $227,421.00 Occupancy Type: Construction Type: Expired: No. Buildings: No. Stories: No. Unites: Details: RIVERSIDE COUNTY FIRE PERMIT #LAQ-14-RS-031. SEE FIRE FOLDER. FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY ART IN PUBLIC PLACES- RES 27000003650500 $68.55 $68.55 3/25/14 Total Paid for ART IN PUBLIC PLACES-RES: $68.55 $68.55 BLDG PC 200K-1M 10160003428200 $1,251.06 $1,251.06 3/25/14 Total Paid for BLDG PC 200K-1M: $1,251.06 $1,251.06 BLDG STDS ADMIN (SB1473)10100002030600 $10.00 $10.00 3/25/14 Total Paid for BLDG STDS ADMIN (SB1473): $10.00 $10.00 Printed: Wednesday, February 28, 2024 2:47:44 PM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER SFD-13-1634 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY DIF CIVIC CENTER - RES 25200003650000 $942.00 $942.00 3/25/14 Total Paid for DIF CIVIC CENTER - RES: $942.00 $942.00 DIF COMMUNITY CENTERS-RES 25400003650000 $129.00 $129.00 3/25/14 Total Paid for DIF COMMUNITY CENTERS-RES: $129.00 $129.00 DIF FIRE PROTECTION- RES 25700003650000 $433.00 $433.00 3/25/14 Total Paid for DIF FIRE PROTECTION-RES: $433.00 $433.00 DIF LIBRARIES - RES 25300003650000 $344.00 $344.00 3/25/14 Total Paid for DIF LIBRARIES - RES: $344.00 $344.00 DIF PARK MAINT FAC - RES 25600003650000 $40.00 $40.00 3/25/14 Total Paid for DIF PARK MAINT FAC - RES: $40.00 $40.00 DIF PARKS/REC - RES 25100003650000 $2,048.00 $2,048.00 3/25/14 Total Paid for DIF PARKS/REC - RES: $2,048.00 $2,048.00 DIF STREET MAINT FAC- RES 25500003650000 $116.00 $116.00 3/25/14 Total Paid for DIF STREET MAINT FAC-RES: $116.00 $116.00 DIF TRANSPORTATION - RES 25000003650000 $2,842.00 $2,842.00 3/25/14 Total Paid for DIF TRANSPORTATION - RES: $2,842.00 $2,842.00 MULTI-SPECIES (MSHCP) FEE 10100002031000 $1,278.00 $1,278.00 3/25/14 Total Paid for MULTI-SPECIES (MSHCP) FEE: $1,278.00 $1,278.00 PERMIT FEES 0 $589.11 $589.11 3/25/14 PERMIT FEES 0 $179.48 $179.48 3/25/14 Printed: Wednesday, February 28, 2024 2:47:44 PM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER SFD-13-1634 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES PLUMBING 2013 - UNDERGROUND PLUMBING KIRK KIRKL 4/1/2014 4/1/2014 APPROVED DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY PERMIT FEES 0 $321.78 $321.78 3/25/14 PERMIT FEES 0 $369.51 $369.51 3/25/14 Total Paid for PERMIT FEES: $1,459.88 $1,459.88 PLAN CHECK, ELECTRICAL 10160003428200 $62.22 $62.22 3/25/14 Total Paid for PLAN CHECK, ELECTRICAL: $62.22 $62.22 PLAN CHECK, MECHANICAL 10160003428200 $185.91 $185.91 3/25/14 Total Paid for PLAN CHECK, MECHANICAL: $185.91 $185.91 PLAN CHECK, PLUMBING 10160003428200 $340.90 $340.90 3/25/14 Total Paid for PLAN CHECK, PLUMBING: $340.90 $340.90 PLAN CHECK, SFD GRADING 10160003428200 $143.00 $143.00 3/25/14 Total Paid for PLAN CHECK, SFD GRADING: $143.00 $143.00 STRONG MOTION (SMI) - RES 10100002030800 $22.74 $22.74 3/25/14 Total Paid for STRONG MOTION (SMI) - RES: $22.74 $22.74 TUMF: RESIDENTIAL 22400002032000 $1,837.44 $1,837.44 3/25/14 Total Paid for TUMF: RESIDENTIAL: $1,837.44 $1,837.44 TOTALS:$13,553.70 $13,553.70 Printed: Wednesday, February 28, 2024 2:47:44 PM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER SFD-13-1634 ATTACHMENTS BOND INFORMATION PLUMBING 2013 - SEWER CONNECTION KIRK KIRKL 4/1/2014 4/1/2014 APPROVED BUILDING 2013 - FOOTINGS KIRK KIRKL 4/3/2014 4/3/2014 APPROVED BUILDING 2013 - SLAB KIRK KIRKL 4/3/2014 4/3/2014 APPROVED BUILDING 2013 - ROOF NAIL KIRK KIRKL 4/17/2014 4/17/2014 APPROVED BUILDING 2013 - OKAY TO WRAP KIRK KIRKL 4/30/2014 4/30/2014 APPROVED BUILDING 2013 - FRAMING KIRK KIRKL 5/12/2014 5/12/2014 APPROVED BUILDING 2013 - INSULATION KIRK KIRKL 5/14/2014 5/14/2014 APPROVED BUILDING 2013 - DRYWALL NAIL KIRK KIRKL 5/16/2014 5/16/2014 APPROVED BUILDING 2013 - LATH KIRK KIRKL 5/19/2014 5/19/2014 APPROVED PLUMBING 2013 - GAS LINE / GAS TEST KIRK KIRKL 6/12/2014 6/12/2014 APPROVED ELECTRICAL 2013 - TEMP USE OF PERMANENT POWER KIRK KIRKL 6/19/2014 6/19/2014 APPROVED FINAL**KKI 8/21/2014 8/21/2014 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES PARENT PROJECTS Printed: Wednesday, February 28, 2024 2:47:44 PM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER SFD-13-1634 January 13. 2012 Sprinkler 149m February 3 2012 Sprinkler 147u FREEDOM"" RESIDENTIAL FREEddIVI RESIDENTIAL I HIGHWAY ill rAIRREONawo ' PENDENT SPRINKLER ' . • CONCEALED PENDENT wade.sea Eir& Pr'viect`ion COrriso06 rrww.lyw°-Rr6 o4rh 1t L/ CRLI 313.3 GENERAL a L I L S AVtTfuE +E1 VK468 (K$.9) SPRINKLEIRVK45741{K4.9j Aroducrs The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49068 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49068 AVENUE 4a Models 88 SO HIP and 1. AUTOMATIC FIRE SPRINKLER SYSTEM HAS BEEN DESIGNED TO BE z Telephone: 269-946-9501 Technical Services: 877-3B4-5464 Fax: 26MI8-1680 Emiail: techsvcs@vikingcorp.corrl Telephone: 26M45-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Spell: ft Application SjPJ'1lnklers INSTALLED IN ACCORDANCE WITH NFPA 13D, 2013 EDITION AND THE AVI¢NUE ao 1. DESCRIPTION 1. L]ESCRIPTION For protecting j�� REQUIREMENTS OF RIVERSIDE COUNTY FIRE DEPARTMENT. [LIJ if Viking Freedoms` Residential Pendent Sprinkler VK468 is a small, thermosensitive, glass- Viking Freedom' Residential Concealed Pendent " ` AVENUE 51 bulb residential sprinkler s-y'r g Sprinkler VK457 is a small The 3peainc Appwaatlon Atr° Span 2. THIS SPRINKLER SYSTEM SHALL BE TESTED AND INSPECTED BOTH in several different finishes and temperature ratings to - high -sensitivity solder link and lever residential sprinkler designed for installation Cmenerot kl*MarethefinGtSfs nWarst0 sat . THE ROUGH AND FINAL INSPECTION PRIOR TO OCCUPANCY BEING � �'' GRANTED, THE JURISDICTIONAL FIRE P � AYEr1UE 52 meet varying design requirements The ❑riFicedesign, with a K-Factor of 4,9 {70,6me;rift}, =• on concealed pipe systems where the appearance of a smooth ceiling is desired_ ry - DeSCII eA . Lt�tedfara,dtlndadoova in ore - .'.' Ew REVELATION OFFICE WILL BE r� - pP allows efficient use of available water supplies for the hydraulically designed fire protection r; h-- - . The orifice design, with a K-Factor of 4.9 74.6 metric allows the rin]der's e# """' toBa buallbk,aannrumian. x NOTIFIED fl MINIMUM OF TWO WORKING DAYS IN ADVANCE OF THE g t W. .I: { }, 5p - -- system. The glass bulb operating element and special deflector characteristics meet theINSPECTION. 1 ficient use of available water supplies for hydraulically designed fire -protection TM • • snlstn9enractfOna¢ HIP, and AP • HbecaefQetasled In REQUESTED AvefrUE ss challenges of residential sprinklarstandarda - - pp Y y 9 p 0CPIL-9)-SpecillcAppAcatkMSPrir1MaM drysyat sowanca system. The operating element and special deflector characteristics meet the chal n ^s w= +�� . Fun -scale teeled, for rrae in wood for a°mbusFibleand wn-combushble tr„ �- �..... 3. THE INSTALLER SHALL PERFORM ALL REQUIRED ACCEPTANCE Av�Nus 5a TESTS, 2. LISTINGS AND APPROVALS i l 1 lenges of residentiai sprinkler standards- ,tnpod.nlcrue ll,eModel ea, so, -* !n I and HIP ereEpacircAppEcationAttc • to Tadtorspearfc oofswpas{rterar 4. NOTCHING, DRILLING, OR OTHERWISE PENETRATING STRUCTURAL ctlLus Listed: Category VKKVV The sprinkler is pre,assemt�Ied with a threaded adapter for installation with slow- � - .- . srlrl,rdera,wneneaatneMeddAPfea taTableA], w W ' - profile small -diameter oover assembly installed flush to the ceili The two-piece speci}OApplcaban � 1��r The spoeffta App6cat[on Attic s f AVENUE s5 Lu l p p �s s peer' MEMBERS SHALL BE 11+1 ACCORDANCE WITH CALIFORNIA BUILDING CORE, NYC Approved., h1EA 89 92-E, Volume 35 pace pdnidsrha9yingspaclnc 6oft proTidethwhestlevel of Prater.- o pp •` design aNays Insfaiatian and testing of the sprinkler prior to installation of tfte - arppMcdtioncritariaforlta6aewitnthe Con cull control ocat ❑y alrminanng NSF Certified: NSFIANSI Standard 61 DrinkingWater System Cam ❑nents cover late. The " ush-on" thread -off" design of the concealed cover late as- Mo-dq sB so, and HIP m seat avao- deed for additional aprinklers and � AIRPORT BLVD O Y p (� p 9 P '::': •:!':� -*a.aplefl°AppYcananAtuesprtiklem branch" piping. In manycaaam, an 5. TYPE OF PLASTIC PIPE TO BE CPVC MANUFACTURED BY BLAZEMASTER Prod Refer to the Approval Chart on page 149❑ and Design Criteria on page 149r for sembiy allows easy installation of the cover plate after the system has been tested 4 ^ " t<.,.: ds s*Oor fire prof ckc In attic attic can be eanirsiy protected with •s ,.,Y U.L. LISTED. tarro aodL1 0 and the Cell In Spaces. and when compared to stem- usl one line of pO" located below . cULus Listing requirements that must be followed_ g finish has been applied, while also providing up to Jx" (12.7 mm) of dew %maySpdnldws, co�,raving4 are Wm peat, of the roof uairlfi Mader ea vertical adjustment. The cover assemblycan be removed and reinstalled. allow- AchivwWd ''e+kWa°Ing°°"r�r"'e"a" (Rwkear�,�sp"•wdara, If#weiea 6. ALL VALVES SHALL HAVE A PERMANENTLY AFFIXED SIGN iNLIICATING VICINITY MAP twtals and the assnctaVd ImPAMMIan need for kWUSI aD (3Ytgle �irectl°nNy 3. TECHNICAL DATA ing temporary removal of ceiling panels without taking the sprinkler system out of labor. "ThsSPscificAPPEcAon sprtn- a Modal HiPSprinitlers.one line 40 ru- IT'S FUNCTION. Akers For Protecting Attc ' have ear- Iheroftmw erWas iswffKder* Specifications: service or removing the sprinkler. dnrgt t1wmoetrita,alveketwUng At each area�a�rad-r-4ramm- N.T.S. Available since 20D6. °"°rpa"°nnadfor er°pedaft 4115 )es. weand su tn*leftuseofStandard 7. PIPE SHALL BE HUNG FROM STRUCTURAL MEMBER PER THE UNIFORM 7T�y era UL Llated with h v& sps&lc Sp ran Sordders, a nyntern n a 60 foot Minimum Operating Pressure: Refer to the Approval Chart 2. LISTINGS AND APPROVALS aPPil=uglAd4irmsforaaeasez (tfl,80vAdeahle,Wtruptoa12,12 PLUMBING CODE. PIPE CLAMPS AND SCREWS ARE MANUFACTURED BY aaispdnkleraandefined bytheNFPA roctpltch, deslgrmdtothe 2007edl- AFCON MFG. ARE U.L. LISTED AND ARE INSTALLED ACCORDING TO THE BELMDNTCOLLECTI4N Specirrc Application Attie 6prin Son of NFPA 13, wpuW requlre seven Maximum Working Pressure: 175 psi (12 bar}. Factory tested hydrostatically to 50d psi (34.5 bar], c uL cULus Listed: Category VKKW T1ia brenchftLAtoCoverthe main por%anor - HANGING REQUIREMENTS IN THEIR TECHNICAL DATA SEE DETAIL). Thread sine: 1 i2" { l5 m m} NPT wars provide an viler dad coverage the attic and sweral adrlr1$mW branch- { a Nominal K-Factor; 4.9 U.S. 70.6 metric Refer to the Approval Chart on page 147w and Design Criteria on page 147x for cU Lus Listing requirements that must be Spacing wlernatb a to ire rea =raj iinea to cover ate NP areas. wth vo { t) sWN ndardsl S'� SpedEcAppliicationA01c3prinMBM, 8. THE SPACING AND LOCATION OF SPRINKLERS SHALL CONFORM WITH followed. +ts tl,erequlredc�wexagerariU blainud THE MANUFACTURES REQUIREMENTS AND THOSE CONTAINED IN TRACT 32879 *PLAN 4.3771 tlltletric K-factormeasurementshowri is in Bar. When pressure is measured in kPa, divide the metric K factor shown by 10.0. sprar; U6t orb branc�hgrta r F09ng bel" G4ass-bulb fluid temperature rated to -65 T (-55"C)deache2oW edition of NFPA tnarpm mkarrdOnodnwneachslopeof NFPA 13D, 2013 EDITION. 13, Table a-e.2.2.t(r1j and seetkxh 10Z rp beam. TM would resuh In ar, .. LOT 216/81305 STORM CAT COURT Overall Length: 2 114" (58 mm) 3, TECHNICAL DATA aA.4AA proxlmatOy9D%1wsplpeneeded far LA QUINTA, CA Specifications: Inatatranon.Thiareductwninthe rwm- 4 9. IF REQUIRED BY A.H.J. THE ALARM INDICATING DEVICE. SHALL BE LISTED LICENSE NO.684600 mar os 6 ante tnaa as as the aasf or FOR OUTSIDE SERVICE AND AUDIBLE FROM THE: STREET THAT THE Material Available since 2048. 'na pie ntunale, harper, and also HOUSE IS ADDRESSED ON. CUSTOM TRACT, MULTI -FAMILY Frame Casting: Brass UNS-C84400 or Q€ul Brass Viking Techtlical Data may be found on darid labor by slkninating up m ti,,aa Deflector: Brass U3�IS-C23000, Phosphor Bronze UNS-051 MO. or Brass Minimum Operating Pressure- Refer to the Approval Chart. ��,;, � The Viking Carporation's Web site at Maximum Working Pressure: 175 sl 12 bar Factor tested hydrostatically to 500 sI 34_5bar Arntlhe Important «tflespe ti AHJ: RIVERSIDE COUNTY FIRE DEPARTMENT AND COMMERCIAL UNS-C26000 9 P { J• Y Yd Y p { }- tills 4p112datahAl6c ink f tecSX I 10. SMOKE DETECTORS TO BE INSTALLED BY OTHERS. w: . htQb silte may lintluds ainc.ra re Thread size: cto 4. min) NPT ►"`�""m ' DESIGN ENGINEERlNGAND t3ulkr Glass, nominal3mmdiameter AAsaya rover ro recnatcar nef8 I"ihersduarioninmyetemvolt9na. Belleville Spring Sealing Assembly: Nickel Allay, coated on both sides with ilia Web site may include a more recant Nominal K-Factor: 4.9 U.S. [7D.6 metric"} �y&.��FR Td+�Yotunaredr,°ud ptma.thmh" Teflon Tape edition of this Technical Data Page. " Metric K-lactw measurement shown is in Bar- When pressure s measured in kPa, divide ly�fW.�Pt s cautions lacing hres clad ypfpevake(and 11 _ RESIDENTIAL CONCEALED PENDENT SPRINKLERS ARE U.L. LISTED AND p 9 P ai<eornp nerd 1oaWbty allow ea LEGAL DESCRIPTION wreflrespea<fa►handlvpexih�staf qu ° 1rrery MANUFACTURED BY ViKING. INSTALLED AT 16 FT, MAXIMUM SPACING INSTALLATION Pip Cap and Insert Assembly: Copper UNS-G11000 and Stainless Steel the metric K-iactor shown by 710.0. lauarr�aprkddaraysbarnleandoort. the Sisal tora4n axaler�r_ {SEE TECW. DATA}, � UNS-S30400 I'Aaterial Standards: Viking Technics! Data may be found on aonpi�rwft�pemranenr� 705 E. HARRISON ST„ SUITE 200 Compression Screw. Brass UNS-C36000 Sprinkier Body: Brass UNS-084400 or LAM Brass The v�kIng Corporation's web sHe at a 12. UPRIGHT INTERMEDIATE TEMP. QUICK RESPONSE SPRINKLERS ARE U.L. OCCUPANCY: R3 1 lJ rlaras andoarse Qre sprWrk�f m Sad CORONA, CA 92879 ordering Information: {Also refer to the current Viking price list.) reflector Phosphor Bronze UNS-C'5100C httpJlwww.viKInggroupinc.com. etea" Pr67Uaa LISTED AND MANUFACTURED BY TYCO INSTALLED AT 120 SQ.FT. SPACING PH - 800-915-3473 Sprinkler: Base Part No. 13537 Deflector Pins- Stainless Steel UNS-S30200 The Web site may include a mare recent (SEE TECH. DATA). CONSTRUCTION: V-Et FAX 951 2I2 2535 Under 5 rinkter VK468 b first adding the a p Button- Brass UNS-C36000 p y g appropriate suffix for the sprinkler finish and then the appropriate suffix for the tam era- edition afthls Technical Data Page. STORIES: 1 • ture rating to the sprinkler base part number, Seat Assembly: Brass UNS C31600 I - Fr • � G«F�".: 13. PENDENT INTERMEDIATEMANUFACTURED TEMP. VIKIN RESPONSE SPRINKLERS ARE U.L. 1:3U{LDING AREA: 4,505 SQ.FT. P' p .Frame '•ems , -sw a - comp p4kr LISTED AND MANUFACTURED BY VIKING INSTALLED AT 16 FT. MAX, SPACING The feci lent le these laps Finish Suffix: Brass =A, Chrome-Enia '= F, and White Polyester = M-AN Compression Screw: Brass UNS-C36000 2-Boson e-Conp..wo, 4-SN,1ing clear beech acknowledges that all y Fusible Element Beryllium Nickel, coated with black ac tic 3 s 9oinr Am" a D`NvW (SEE TECH. DATA), plans, specifications or Temperature Suffix. 155'F (88 °C) 2 B, 175 "F (79 `C) = D y ry rY paint xaaaaatV e- Ddr.mr a Enos r EMMM p Levers Stainless Steel UNS S3f5pp d•1fe 2 • a.b aplrp FIRE SPRINKLER SYSTEM: methods of installation For example, sprinkler VK468 with a Brass finish and a 155 °F (68 `C) temperature rating = Part No. 13637AB. r-tce,0mm1 6sRraru ,-,, g. 14_ PENDENT SPRINKLERS ARE AT LEAST 3 ff. FROM OBSTRUCTIONS E.G. LIGHT 0ESIGNE❑ AND INSTALLED PER 2013 NFPA 13D ALL contained in this set of plans is Lever Bar: Copper Alloy UNS-C72500 ,.ins t-1fs• ""ro'' } the sole property of Fire Available Finishes And Temperature Ratings: r FIXTURES, CEILING FANS, ETC. OR IN ACCORDANCE WiTH TABLE $-2.5.4.2 AND RESIDENTIAL WITH A .05 DENSITY WITHIN AREAS. Beiieville Spring Sealing Assembly: Nickei Allay, coated on both sides with Teflon Tape r lTr,6mnk {s,¢rro0 r e Sprinkler Systems, and Refer to Table 1, I SECTION 8.2.5.2. SPRINKLER LOCATIONS FOR CONTINUOUS OBSTRUCTIONS that an use s this set Inc.c land Cover Adapter Cold Rolled Steel UNS G1€ }80, Finish: Clear Chromate over Zinc Plating 5- arn►vlILra ARE IN COMPLIANCE= WITH $.2.5-4. Y rFLWE is prohibited and is a violation Accessories (Also refer to the "Sprinkier Accessories" secton cs# the Viking data book) Shipping Cap Polyethylene e� of P copyright laws without first Sprinkler Wrenches: Cover Plate Materials, d�. a-r14 SUMMARY + I ,� q p p a ' 2,e�• f R1�'� 15, SOFFITS AND CABINETS TO BE PROVIDED WITH SPRINKLER COVERAGE IN BUILDING �7UMIYii'-1ii Y receiving peemission from Fire A. Standard Wrench: Part No. 10896WIB {available since 2000) Cover Plate Assembly: Copper UNS-ClIO00 and Brass UNS-C25800 - 2 tE4Ad 0 '� ACCORDANCE WITH 8.3.3. 5 rinkier Systems. watrrca - 8. Wrench for recessed sprinklers: Part No. 135774V1S` (available since 20os) Spring Beryllium Nickel s-REUIgF 2f 16. SPARE SPRINKLERS SHALL NOT BE REQUIRED TO BE PROVIDED IN C. Optional Protective Sprinkler Cap RemioverlEscutcheon Installer Tool"" Part No. 15915 (available since 2010.) Solder: Eutectic -- t 1fa•gPr ACCORDANCE WITH 5.1.1-1 1T ratchet is required (not available from Viking), Ordering Information: (Also referto the current Viking price list.} „a (,, mm- 1mIr1PT 7tta•t,,, s„y 1 ID CONCEALED RES. PENDENT SPRINKLER "Mows ii9e Tram the flax by attaching a length of 1" diameter CPllC tubing #o the t od. ideal for sprinkler cabinets Refer to Bulletin F 951$06_ Viking Freedoms Residential Concealed Pendent Sprinkler VK457 and Cover Plate Assembly rrlUSt b2 Ordered separately: N W1EvcH rwwE: NOA - �� ranks uses o>rasa aFCTIan tievrrorr sa:drmrl wa.ewrlrarl UPRIGHT QUICK RESPONSE SPRINKLER Form No. F�0127L]S Replaces page 149m-t, dated March 18, 2C111. [Revised Form No. F 1772EO7 Replaces }cage 147u-z, dated Sept. 9, 2011, (Added QM crass � CONCEALED RES PENDENT SPRINK ER sprinler materials and added reference to TIA 1028R. ) { E TABLE -SPRINKLER a Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' i3uiq Color C9iting Temperatures Ordinary 155 ' F ('58 =C) 100 F (38 -0) Red Intermediate 175 "F (79 'C) •150 F (65 "C) Yeiiow Sprinkler Finishes: Brass, Chrome-Enloy'' (patents pending), and White Polyester Footnotes The sprinkler tenglere ture rating is Aampad on the deflector, � *aaSed on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and ether requirements of Authority Harting .fudsdiction. Refer to specific Installation standards Approval Chart Temparatura KEY Residential Pendent Sprinkler VK468 Flnsih For systems designed to NFPA 131310 or NFPA 13R. A x+-Ew bt. Ivappicable) Far systems designed to NFPA 13, refer to the design criteria on page 149r. Sprinkler Base SIN NPT Thread Size Nominal K-Factor Maximum Water Overall Length Inches mm U.S. metrics Inches mm Part Number' Working Pressure 13637 VK468 112 15 4.9 70.6 175 psi (12 bar} 2-1/4 1 58 Listings and Approvals' Maximum Areas of Coverage* Minimum Water Supply Requirements* (Refer aiw to Design Criteria on page 149r.) cULuse NYC' NSF° Installed below smooth, fiat, horizontal ceilings, including ceilings with slopes up to and Including 2112 (9.5°)- 12 ft. x 12 ft. (3.7 m x 3.7 m) 13 gpm @ 7.0 psi (49.2 Umin @ 0.48 bar) A1X AIX A1X 14 ft- x 14 ft. (4.3 m x 4.3 m) 13 gpm @ 7.0 psi (49.2 Umin @ 0.48 bar) A1X A1X A1X 16 ft. x 16 ft. (4.9 m x 4.9 m) 13 gpm @ 7.0 psi (49.2 Umin @ 0.48 bar) A1X A1X A1X 18 ft. x 18 ft, (5.5 m x 5.5 m) 17 gpm @ 12.0 psi (64.4 Umin @ 0.83 bar) Al X A1X A1X 20 ft, x 20 ft, (6.1 m x 6.1 m) 20 gpm @ 16.7 psi (75.7 Umin @ 1.15 bar) At x A1X A1X Installed below horizontal ceilings with beams'. 121 x 12 ft. (3.7 m x 3.7 m) 13 gpm @ 7.0 psi (492 Umin @ 0.48 bar) Bix Bix B1X 14 ft. x 14 ft. (4.3 m x 4.3 m) 13 gpm @ 7.0 psi (492 Umin @ 0.48 bar) Bix 131X 131x 16 ft. x 16 t. (4.9 m x 4.9 m) 13 gpm @ 7.0 psi (49.2 Urnin @ 0.48 bar) Bix B1X Bix 18 It. x 18 ft, (5.5 m x 5.5 m) 17 gpm @ 12.0 psi (64.4 Umin (0 0.83 bar) Bix B1X Bix 20 ft. x 20 ft. (6-1 m x 6.1 m) 20 gpm @ 16.7 psi (75.7 Umin @ 1.15 bar) B1X B1X B1X Installed below ceilings with slopes11 up to and including a 8112 (33.7e) pitch. Refer to Figure 5 on page 149q. UL NYC NSFe 20 ft. x 20 ft. (6.1 m x 5.1 m) 21 gpm @ 18.4 psi (79-6 Umin @ 1.27 bar) Bix See Footnote7 B1x 20 ft. x 20 ft. (6.1 m x 6.1 m) 23 gpm @ 22.0 psi (83.4 Umin @ 1.52 bar) Cix see Fwtnate7 CiX Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 155 IF (55 °C) and 175 `F (79 `C) °F °C) 1 - Brass, Chrome-EnloyO, White, and X - Standard surface -mounted escutcheons or the Micro- B - 155 (6a Black" faste Model F-1 Adjustable Escutcheon, or recessed with C - 175 °F (79 'C) the MicromaddO Model E-1 or E-2 Recessed Escutcheon Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price Est schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. ' This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturerfor any additional approvals - `For areas of coverage smaller than shown, use the'Minimum Water Supply Requirement' for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum Water Supply Requirement' used. s Listed by Underwriter's Laboratories for use in the U.S and Canada. ' Accepted for use. City of New York Department of Buildings, MEA Number 89-92-E, Vol. 35. Meets New York City requirements, effective July 1, 2008- e Tested and Certified by NSF (National sanitation Foundation) to NSFIANSI Standard 61, Drinking Water System Components. e Listings are for residential occupancies with smooth, flat, horizontal ceilings or horizontal ceilings with beams. Includes c6lings with slopes up to and mduding a 2112 (9,51 pitch- (For beam oeiing design viieria, refer to Beam Q*i g Guidelines and Figures 6 through 7D on pages 149s-t)- 10Refer to TIA 1028R slope ceiling criteria exceptions. "Areas odder sloped ceilings must be measured along the oefling slope. AOvat floor coverage in the horizontal plane under sloped ceilings will be less than the listed area of ooverage- 120ther paint colors are available on request with the same cULus Listings as the standard finish colors, MM IwBETIll (Also refer to the Approval Chart w page 14 So) cldLus Listing Reautt@)nents: When using Viking Resident.al Pendent Sprinkler VK468 for systems designed to NFPA 13❑ or NFPA 73R, appl}rthe listed areas of coverage and minimum water supply requirements shown in the Apprcwal Chart on page 149o. F2[ systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous 1Yhost hydrauGcalty demanding sprinklers. The min> - mum required discharge from ea[h Df the far sprinklers is to be the greater of the fcilomng: The flaw rates given in the Approval Chart on data page 1490 for NFPA 13D and NFPAI3R applicBtlons for each listed area of coverage, UL Calculated based cn a minimum discharge of 0.t gpmisq_ ft. over the `design area" in accordance with sections 8.5.2.1 or 3-6.2-1.2 of NFPA 13. - Minimum distance between residential sprinklers; 8 ft, (2,4 m) to sprinkler materials and added reference to TIA 102t3F�. TABLE i: 1 Sprinkler WnMiw Nominal Maximum Temperature Rating Cover Plate Large Cover Square Gover Tem perature Temp re Ambient Ceiling of the Cover Basis Part Plate Base Flaw Base Classification Kovno, Tempp'at w Assembly (R"uined) Numt)eP Part Number' Part Numbe;4 Ordinary 165 `°F (74 "C) 100 "F (38 "C) 135 ' F (57 C) 13504 13642 15394 Cover Plats Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushes! Copper, Painted White, Painted Ivory, or Painted Black Approval Chart 3pankarTempe alure Re11n0 Residential Goncoated Pendent Sprinkler VK457 �Covar Pals remPeraum Rae g For systerne designed to NFPA 130r or NFPA 13R. Awt+ovrerPlale Fhksh KEY For systems designed to NFPA 13, refer to the design criteria on page 147x. Sprinkler Base SIN NPT Thread Size Nominal K-Factor I Maximum Water Inches rhlm U.B, m c' Part Number' working Pressure 14694A VK457 1f2 15 4.9 70-6 175 psi (12 bar) Listings and Approvals' Maximum Areas of Coverage' Minimum Water Supply Requirements' (Rafet also to Design Criteria on page 147x.) cULus' NYC NSF' Installed below smooth. Rat, horizontal ceilings, including ceilings with slopes up to and including 2112 12 ft- x 12 ft. (3.7 m x 3.7 m) 13 gpm @ 7.0 psi (492 Umin @ 0.48 bar) AX1 See Footnote 6. AM 14 ft. x 14 ft. (4.3 m x 4.3 m) 13 gpm @ 7-0 psi (49.2 Umin @ C.48 bar) AX1 see Foa1n019 5. AXi 16 ft. x 16 fL (4.9 m x 4.9 m) 13 gpm'@ 7.0 psi [49.2 Umin a48 bat) AX1 sea Fwh)oo 5- AX1 18 ft. x 18.fL (5.5 m x 5.5 m) 17 gpm @ 12.0 psi (64.4 Lhrlin @ 0.83 bar) AX1 see Footnote 5. AX1 20 ft. x 20 ft. (6-1 m x 6.1 m) 20 gpm @ 16.7 psi (75.7 Umin @ 1-15 bar) Axt sea F°otnom 6. AX1 Installed below ceilings with slopes' up to and including a 8112 (33.7°) pitch. Refer to Figure 5 on page 147z. UL NYC NSF' 16 ft. x 16 ft, (4.9 m x 4.9 m) 26 gpm @ 28.2 psi (98.4 Llmin @ 1,94 bar) AXI see Foomotas. AX1 18 ft. x 18 ft. (5.5 m x 5.5 m) 31 gpm @ 40-0 psi (117.3 Umin @ 2.76 bar) AXi see Footnole5. AX1 20 ft. x 20 ft. (6.1 m x 6.1 m) 31 gpm @ 40.0 psi (117.3 Umin @ 2.76 bar) AX7 sea Foouhols 5. AXi Cover Temperature Rating Cover Plate Finishes Sprinkler Temperature Rating X - 135 °F (57'C) cover 735t34', 73642' (large diameUer), 1 - Polished ChromeBrushed Chrome, Bri ht , g A - 165 °F (74 °C) or 15394' (square cover plate) Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black" �A19D f efor to the Approval C hait oil page 14Av. ) When using Viking ResldenUal Concealed Pendent Sprinkler VK457 for systems designed to NFPA 13L) or NFPA 13R, apply the listed areas afcover- age and minimum water supply requirements shown In the Approval Chart on page 147w. Fg[nstems designed to NFPA 1al. The number of design sprinklers is to be the four contiguous mast hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinkteFs is to be the greater of the fdfowing: " The flow rates given in the Approval Chart w data page 147w for NFPA 130 and NFPA 13R applications for each listed area of coverage, 2L Calculated Based an a minimum discharge Df 0.1 gpmisq, ft, overthe "design area" in accordance *ith sections 8.5.2.1 or 8.62.1.2 of NFPA 13. Minimum distance between residential sprinklers: 8 ft. (2.4 rn). NOTE: Concealed sprinklers must be installed in neutral ar negative pressure plenums nnly. FIGLtR F P L FIGURE F AMPEL AP WTM 4.2 or 5.6 K-FACTOR SPECfM �OSKJPPLCA7f5 CONCEALED ANAM0PRNLERS PACESP6 O CHANGE IN ELE'. hTlerj LU SPF Apallod Id4r l"pri p'"1 Technical Operation Inalaldo In the pPnyM onehe With RISER LOCATION (PER DETAIL) CD raer Mein denedar parallel fo the root, the Data FIa [IC®B.9 &4.2), 141P tMGm-aj (FigureF)arein- SprinkieFbe 6AP1wabu[b Uj 16nd&Modtto on lendad in he used to provide pahtriecplon Approvals Tire glees bulb wnteine a 11u1d teat ex• X�C NODE POINT FOR CALCULATION of ai tic areas miside the scope of ap. LA & C-UL Listed- Mba appravaJa Dory ponds whom exposed to heat When the pklca1Ion for the BB, 50. or HIP Sprin- apply to the w0co conditions indl• rated temQarefure la reached, the fiuid J Iera. When used, the AP Sprkrklers catee ry t4e pesign Criteria section on expands Sufficiently to shatter the glees will pro,Ada a hydraulic ndventage over Pao 6 and,he Deaiga Gadelinea aBP buU filmmng the sprinkler to activate � HANGER TIC DETAIL Standard Spray Sprlr>tclers for the pro- bon on Page 8,) and water to Mow. toctlon of atilt areas outside the 5=>0 01 appplication for the BB, SID, or HIP PI Thread Caenaaion BB pf.6 Bl & SO (K�.e) riprinkierS. inch NPT far K=4.2 & 5.6 314 inch The assembly fa NP o link W Oned by NPT for K=8.0 of two link halves vAric#h are fdned b1' S YMBDL LEGEND ` Dlaeherge CaeHieienl 8 tin layer of solder. when Ills rated K = 4.2 PMIpeI'n [&05 LPMfbarr) teanperaltRa Is reached, the colder ire two k le halves sate ad o. K .- S.E GPMIpsi,r. (b6,fi LPMfbarlq meow Mowing slowing the sprinkler to acnvata and K = 8.0 GPMIpsi'� (115,6 LPhRrbarV�J hwater to slow. Ten4Ne ture Radiate Intermediate Temperature as follows: for 613 & Ke)0}, -200°FI93°C (K4.2 HIP, AP Uj -212'F1100°C for 56 (K5.6), Sri afaPEL K ghN ALLOWAE3LE R [e) IN Feet [m) f' aEWIMUM FLOW. FLOW• aPM fWm} MIMMUM PPEASl1FtE PSI (bar), F%W Dewy Runf V , CEYPIPE SYSTEM Wxymm WATER DELIVERY TIMl, Sea4rlee Bel 9.0 TY41 on 5Eo (118,3} 8e 044) 22.E (1,5) 4-12 (,93J to less than 712 04 (01 B152 0.0 TY4161 :A0 011.3) 38 (144) 224 (1.5) 71.12 (58} la lass Ihm 102 (d B83 9.0 iY4102 tea 11s.3) 40 052) 23.0 (1.7j 10:12 (93) r° 12:12 (1IIC} (r) Bat fi.6 TY3fao s40 (12,2j 10 ae0(19,3j 3a (f 44) 48.00,14 4,12 099 to love than 7.12 B82 6-a TY8191 r40 (12.2) to 60 08A M (144) 49.0 (3A 712 (58J ra less than 1012 [SSj (g B83 5,6 TY31e2 �a0 (12.2) to a0 pa.M 3e (144) do-op-1 1012 (W ra 12:12 (1010 p:) 9131 6.8 TY3180 i40 (12,2) 25 (95) 2A.0 (1,4) 4t12 M to lees. than 7.12 (54 (4 Bat 66 TYa161 540112,4 26WB 20A(1,41 712(aAtoleee1han1072gAaj (ra 10133 6.8 TY3102 I ar0 (12A 25 W 20,0(1,4 10:12 (EM 1. 12d2 (100 N Bat 42 TY21an 1 i20 i6,1) 13 (48) 9.8(0.7) 3:12 i251 to Iwo than 7:12 T* 45 Ml BB2 42 7Y21al 9201011) 1314B1 9.5 A7r 7:12 (58) to leas Doan 10.12 RM 4s (d) 11383 42 TY2192 s20 (6,1) 13 KM %6 t0,7r 10:12 (am 10 f2:12 (100 45(d) SD1 6.6 TY3183 ran R 1)10 t40 02,2) 35 030 39-0(2,7} 4:12 (33}to Ieaath n 712(59) fq 5D2 5.a TY3164 .30 0,1)10 540 rI2A 35 (132) 39-012,71 P12 158) to leas 14w 10:12 WM fd SD.3 6A TY3185 5,30 R,1) to td0 02,2} 35 032) 39,M,7) 10:12 (0 to 12-12 (iOo) [c] 5D1 6A TY3fa3 >70 p,OI to s30 (B,1) 26 (BS) 20.0(1,q 4,,V 03i re awe than 7n.4 (big (c} SD2 66 TY0184 10 (3,0)10 5$P ((%1 } 25 (rut} 2a.a (1.4) 7:12 tr+ai tv Ipw Doan 1012 t83] qo) SD3 54 TY3f8S AID (2,0) to 2:30 p.1} 25(95) 20.8(1.4) 10:12 (8%to 12:12 (100) (c} ant 5.6 TY3163 t10 Ao, 19 V4 11.6 (0,a) 412 (S9}1e leas than 7:12 t58l (7} 202 .Le 7Y3104 00 P.M 19 CM 11,3 fog 7'12 (59) to leas imam 10121a3J iI•± S➢3 aU TY3195 00 (3,0) 19 cm - 11.5 Mal IE)A2 W) to T2:12 (SAD) [a} HP 5.6 TY3197 a20 (s,i) to S26 (9,a) 34 (1M) 39.0{Y ) 4:12 pa} to I2:12 0 op 0 HIP 69 remaT i20(d,1) 25p5j 20.(1(1,4) 4:12ff4loIZ-12000) (a} AP 5.6 TY3190 10 MI) x 1213,8) .gqe neLe{e} mum 0. 07 0 (q.4814" M1gF (4,1 mri"njne9lpn Dws ty g:12 (25J to 72.12 pop 600) AP 4.2 TY2100 3:12 = fo 1212 (100) a0 fd] NOTES: (a) The BS and SD roof span Is maasur°d lvrf a airy (rat alnrxj me ampa)ae rr� in Flgura 1 arW 2. (b) The HIP roar span is isms wd hcnzwteify m u-mvn in FIS m 12. (c} IMm to Mr adibw of NFPA 13, Seution 7.2.8. (d) btu um w Iw dalkery time tar 41 sin of sysiams. fa) The AP mar SW is measured Wong the slope. Ntaximrlm 10 Feet (3,1 ml parpendicutar to alcpc by maimim 12 real (3,8 m) psra4e1 to slope. W APPROVAL RIVERSIDE COUNTY RRE DEPARTMENT LISA NOTrINGHA , FSS - i I'�' PHE FIRE DEPT A11PROVAL FOR PLANS VALID FOR ONE YEAR SIJt3ILsCF T O C 1 � CC.) MMPLIANCE �N1Ti�t APPLICABLE CODES Q] '� za0 � } Z _ APPROVAL STAMP J CP J CV wr�,r� o J 0 10' ELEV. m HYDRAULIC SYSTEM ci7vc TO srsTtwM - PRESSURE REGULATOR *FOR REFERENCE ONLY JOB NO: 31 197 TO BE SET AT 60 PSI DATE: 3f1 D114 This Building is Protected by a TO DOM PTIC WATER SPARE SPRINKLERS SHALL _ Hydraulically Designed CCNTRU' VALVE FOR DOMESTIC NOT BE REQUIRED TO F DRAWN BY: F.L. Automatic Sprinkler System. 5 GPM A LOWANCE PROVIDED PER 5.1.1.1 r- 1 8' ELEV. Date installed 3112114 c� I °� Location CALL AREA •1 � 1°CPVC RISER Q�p�� �Q4'J� 4 z' ELEV. GAUGE I 14-1 J2' x 30" k. CLASSIFICATION Number of Splinklers 2 /ACCESS 00OR C-, * LICENSE NO. Basis of Design CONTROL BALL VALVE 1!2° tu1AlN lj N VALVE 58450D 1. DENSITY .05 gpmisq.ft. 2. DESIGNED AREA OF DISCHARGE FINISH GRADE p' ELEV_ DRAIN TO. E ERIOR STATIC 80 -10°k = 72 PSI OF CAL t fp�� 512 sq.ft, I I RESIDUAL 20 - 10% = 18 PSI 1'/" COPPER L 1" METER I FLOWN 1500GPM 1. WATER FLOW RATE 26,0 gpm System Demand 4 PSI L085 RUBBER FACED CHECK VALVE' SIZE - 24" X 36" L- WATER FLOW INFORMATION iii � � _ J 2. RESIDUAL PRESSURE AT THE 4" PVC 1" COPPER K METER 411 SCALE BASE OF THE RISER _ 32.8 psi 3 70' N.T.S. MAX 30 MAX ALL WORK FOR FIRS SPRINKLER _ f -1.5' ELEV. SYSTEMS, INC. TO BE i[N AT B.O,R. IF SHEET 15 LESS THAN Installed By Fire Sprinkler Systems, Inc. � ` 24" x 36' 1T 15 A REDUCED -1.5' ELEV. -1.5' ELEV. PRINTSCALE REDUCE ACCORDINGLY n SHEET ID HYDRAULIC NAMEPLATE UNDERGROUND DETAIL RISER DETAIL GENERk NOTES N.T.S. N.T.S. (FOR REFERENCE ONLY) N.T.S. SHEETFPI0FFP3 4z — - --- I V-0" CLG I. 6'-2" I MASTER BEDROOM j II Z-V CLG j "mow"_j 11'-0" CLG I i wit. t 1 84. 3'-8' I Z-6 GV 4'-5' " 5-2 I \■ MASTER-BATHRO 10'-0" CLG RISER LOC ----------------------------------- __..... ............. ........... .__._._.._ . . ...... ... jl II II VERANDA I V-Cr CLG l I I I �i I iii _ _...-...... . ..... ............. ... _...... ...... _ __-__-_ - .- ...... .... . .......... M IT-O" CLG I --� T'T I 1 CV 14' — f cat J* Jf 11' S' 14' AT ZONE I GREAT ROOM HEATC 1TCHEN 12' 0" CLG I 1'-a" cLG I li CAL C AREA ? 14 I I L_.._ _... ........... .......S-. 5' 10" 14' Es INA I I 9-O' CLG I 1 " 2'-6" 07 ........... Ir.. 1€ (RIGHT SPRINKELf� 1 ROVIDE PrOTE(�,F 2' 3" Z-2" 3, 4' 3" I 1 1 f "" n 1 rti1 ll i it i C ! T-V APCESS 1LAUNDRY i � y 1i pe r 1-3" 10'4' W.I. . 12'-7" " I 3 - CAR GARAGE 1I�1a 10'-0' CLG ap r I 2' 3" 11 10'-4" 1 O'bM 2/ 9'-0 CLG 44 SQ. FT. L 11'-0" CLG 9'-O° CLG ,..._.._... �.... .._..._�. .._..----- - ._._... 16' s'-10" V-2" ! 7' __ 9'-0" CLG® 4'-10" 3'-2 11 '-O' CLG ! _. _......_.. l` it DINING ROOM 12'-0" CLG I 1V T-10' 3 G I ® o r- 1T-O" CLG POWDER 9'-0' CLG 4'-1" 11'1 42 SQ. FT. 4' 9" ENTRY 10'-0" CLG f rQ BEDROOM 2 10'-V CLG 12 T 10, ......... _..,,,...... .......... . --....._-....-- FIRE SPRINKLER PLAN SCALE:114" =1l-0" CV COVERED COURTYARD toy `�7 II I 1 1 1 I I COURTYARD BEDROOM 4 10'-O" CLG I 6' Sfl N ATHRoa CAL C AREA � "CLG 20'x20'SPACINIG 10, + I 13 I I I I` " I I; _._._ 20'x20' SP4ING_ - I 10' W:I:C. 4 10'-O"CLG 9"'tj -..- 126 W,I.0 CLG — r 4'-5" VERANDAI IBEDROOM3 10'-0"CLG �r . 01 h;��� SIZE • 14, Ihru 2" T ipe MATERkAL • Carbon Steal FINISH - Mil Gelvenlzed LISTIN S UL Usled: EX 4231. Ex 2551 PATENT - No. 6,648.276. FUNCTION - To support horizontal piping - CPVC, Copper w Steal A listed hanger in all 3 mourapng posilion, i.e. side of vertical sedate end both topside and underside of horizontal surface. A Ifs:ed retreIner providing vertical and laser restraint ire al the ebore rnouning positions. To pree,ent upward amvalxient of pipe that supplies a penden, sprinkler fLastratnl below the ceding. ra ssbelxe vertical piping by providing horizontal restraint. INSTALLATION - Per INFPA 130 Space by pipe type. Insl"II on wood- cti7ncreaea srael. Snap aver pipe, they, squeeze strap back allovAng pipe to s"a freely. When P 905 threuds are exposed in woad, nsaM #906 bacidng red. FASTENERS• 'WOOS' ULLlsled pc; 24FPA 13 CPVC pipe - 9905 stray - no pno-dn! Copper pipe - #905 screw - r pre-dril Steel pipe-1la-"11rr lag sure -rw P'"rill R�-v Lit Thm 518" gyps4'n hoard - 114'xt' lag saaw 'STE€4- t1t. Listed par NFPA 13 - men 18 GA CPVC ppe - 114- w #14 Tak Screw Copper pipe - I or #14 Tek screw Steel pl pa - 114" or #14 Tak Screw 'CONCRETE' Required minimum load each fastener The higher of I m bo or 5fw11+25LNSs 2' FEATURES- - 1 V2, Orfael - pipe vm1 to mow ing surface 3M' and i' pipe size made with c mnaon canlemim Lag daalgr, produces supe"or strength 'Offael edge ellminewe abrasion ' AFCON N905 sa listed lorwood has Si 6* hex hand - lududed ORDERING - Part M and plpo size Nominal Pipe Size (in.) '/," 1" 11/4' 1'A' 2" 2'/V 3" 3'l2' 4" 5' 6' 8' Steel pipe except threaded N14 12'4' IZ-0' 15'-0" 1T-0" 15'-0" 164' 15'-0" 1F-O' 15'-4" 15'-0" 15'-0" lightwall Threaded lightwall steel NIA 12'-O" 12'-0" IZ-O' 12'-0' 12'-0" 12'-0" NIA NIA NIA NIA NIA pipe Coppertuhe R-O" 8'-0" 10'-0" `!M' 12'-W 12'-0" 1Z-0" 15'-0" 15'-0" IS'-0" 15'-0" 15'40" CPVC 6-6" 6'-0" 6%- : 7'-0" 8'-0' 9'-0" 1 Y-0" NIA NIA NIA NIA NIA Polyhutylene (IPS) NIA 3'-9 4'-7" 5'-0" Y-11" NIA NIA NIA NIA NIA NIA NIA Polybutyl4ene (CTS) 2'-11" T-d" NA V 4'-0" 5'-5- NIA NIA NIA NIA NIA WA NIA Ductile iron pipe NIA NIA NIA NIA NIA 15'-0" NIA NIA IT-O" NIA 15'-0" 15'4r 514 STEEL - COPPER - C. P. V C. HANGER NOT TO SCALE 21 A l �k SIZE & PIPE TYPE - 3r4" THRU 3" C.P.V.C. PIi"E LISTINGS - UL LISTED, EX 4231, EX 2551 INSTALLATION - PER NFPA 13D INSTALL ON TOP, BOTTOM OR SIDE OF BUILDING ELEN " SPACE BY PIPE TYPE FASTENERS - in WOOD: 314" - 3" CPVC PIPE - #905 SCREW - NO PRE -DRILL in STEEL: 34' - 3" CPVC PIPE - 114" OR 014 TEK SCREW Nominal Pipe Saxe (In.) 1'/," 1 W 2" 2'/" 3' 3'!s" 4" 5" Steel pipe except threaded I ightwall NIA 12'-0" 174' W-0" 16-0" 15'.0" 15'-0" 15'-0' 15'-0" 15'-0" 15-0' 1V-0' Threaded lightwall steel NIA 12-0" 12'4' 12'4' 1Z-0' IZ-0" 12'-0" NIA NIA NIA NIA NIA pipe Copperwll a 8'-0" 8'-0' 10'-0" 10'-0" 12'-0" 17-0" 12'-O" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0' CPVC 5-6' 6%0" 6'-6' 7'-0" 8'-0' 9'-0" 1V-0" NIA NIA WA NIA NIA Polybutylene (IPS) NIA 3'"9' 4'-7' 5'-0' 5'-11' NIA NIA NIA NIA TA NIA NIA Polybutylene (CTS) 2'-11' 3'-4' T-11" 4'-5' 5'-5" NIA NIA NIA NIA MA NIA NIA Ducdle iron pipe NIA NIA NIA N1A NIA 16-0" NIA NTA 16-0" NIA 15'-0" 15'-0" 510 STEEL - COPPER - C. P. V. C. HANGER NOT TO SCALE TOTAL LIVING AREA - 3,771 SQ. FT. 3 - GARAGE -AREA- 734 SQ. FT. DESIGN AND INSTALLATION SHALL CONFORM TO NFPA 13D, 2013 ED, NOTES: 1- ALL HEAD SPACING TO BE 15'x16', UNLESS OTHERWISE NOTED. 2. ALL PIPES TO BE 3I4" CPVC, UNLESS OTHERWISE NOTED, 3. PIPE CLEARANCES MUST BE IN ACCORDANCE WITH NFPA 13-9.3.4. 4. HANGERS SHOWN FOR REFERENCE PURPOSES ONLY. HANGER SPACING TO BE PER TABLES ON THIS SHEET. 5. UPRIGHT PROTECTION TO BE PROVIDED ATANY FAU WITHIN THE ATTIC. RISER PIPE AND FITTINGS TO BE Y" CPVC WHICH WILL BE INSULATED ALL AROUND. 6, ALL PIPING INSTALLED WITHIN THE ATTIC SHALL BE PROVIDED WITH MIN. 6" INSULATION ON THE ATTIC SIDE OF THE PIPING TO AVOID EXPOSURE OF THE: PIPING TO TEMPERATURES IN EXCESS OF THE PIPES RATED TEMPERATURE (2013 NFPA 13D 7.7). 7, SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55sgft, AND LESS. (SECTION 8.3.2.) 8. SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THAT MEET ALL OF THE FOLLOWING REQUIREMENTS: (1) THE AREA OF THE SPACE DOES NOT EXCEED 24sgft. (2) THE LEAST DIMENSION DOES NO EXCEED 3ft. (3) THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED -COMBUSTIBLE MATERIALS AS DEFINED IN NFPA 220. 9. 8.2.5.3.2 THE DISTANCE SHALL BE MEASURED FROM THE CENTER OF THE SPRINKLER TO THE CENTER OF THE OBSTRUCTION, 0 w Lu d 0 0 Z svblrwm INC. f LICENSE NO.684600 • CUSTOM, TRACT, MULTI -FAMILY AND COMMERCIAL ■ DESIGN, ENGINEERING AND INSTALLATION • 705 E. HARRISON ST., SUITE 200 CORONA, CA 92879 PH - 800-915.3473 FAX - 951-272-2535 The recipient of these plans hereby acknowledges that all plans, details, specifications or methods of installation Contained in this sat of plans is the sole property of Fire Sprinkler Systems, Inc. and that any use of this set of pplens is prohibited and is a violation of copyright laws without first receiving ppermission from Fire Sprinkier Svstems. F_ Z d Z) C3 Lo ( LU LIU Z m I = U)>> 0 F_ ~ Z L) r 0 Z x x CO Cl) rn r � a 0 0 Z ' LU r CN J LU r o 0 r rn SG O 00 (1] _jLLJ ❑w g� C)�w�¢ Ld Z �a a LL� z Q a z 1 Q C3 L z00 CIO cr- LU CO C� � C)�cn_j T F„ rV � o JOB NO: 31197 DATE: 3110/14 DRAWN BY: F,L. i�� I oIv CQ�� rP CLASSIFICATION C-16 * LICENSE NO. 684600 SIZE - 24" X W SCALE 1f4" = 1' IF SHEET IS LESS THAN 24" X 36" IT IS A REDUCED PRINT SCALE REDUCE ACCORDINGLY SHEET ID PLAN 4.3771 FIRE SPRINKLER PLAN SHEET FP2 OF FP3 11 DATE: 3/12/2014 S:\2014\31197\C'_�\PLAN 3771.rdf Page 1 FIRE SPRINKLER SYSTEMS 705 E. HARRISON, SUITE 200 CORONA,CA 92879 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR BELMONT COLLECTION "PLAN 3771" LA QUINTA, CA TRACT 32879 10% TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN CALC AREA 1 Date: 3/12/2014 File No: 31197 Data File Name: PLAN 3771.rdf SPRINKLER SPACING 256.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 16.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 8.0 ft. SPRINKLER SPECIFICATIONS Mfr: Viking Descr: VK457 Conc.Pend.(16xl6) K=4.90 Calculated K Factor for Arm-Overs & Drops: 1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee) 0.0 ft. x 0.874 in. Arm -Over: K=4.67 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 72.0 psi Resid: 18.0 psi Flow:1500.0 gpm Public Main Size: 8 in Domestic Demand: 5.0 gpm at node number 4 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press, Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 13.0 7.6 14 18.0 72.0 28.0 2 13.0 7.6 14 31.0 72.0 52.8 REVIEWING AUTHORITY RIVERSIDE COUNTY FIRE DEPARTMENT DATE: 3/12/2014 S:\2014\31197\C'-'�\PLAN 3771.rdf Page 2 RESULTS OF ANALYSIS PIPE & NODE DATA * FLOW ANALYSIS * 1 sprinkler flowing * 2 sprinklers flowing FIXD P # END LEN FIT. LOSS EL SP *DISCH FLOW PF PT *DISCH FLOW PF PT HWC NOD DIA EQV.LN PUMP (FT) (K) *(GPM) FL/FT PE (PSI)*(GPM) FL/FT PE (PSI) 1 1 30.00 B ---- -1.5 SRCE ---- 18.0 3.29 28.0 ---- 31.0 9.01 52.8 150 2 0.995 6.0 ---- -1.5 ---- ---- 0.09 0.00 24.8 ---- 0.25 0.00 43.8 2 2 70.00 150 3 1.360 ` 3 3 4.00 150 4 1.265 3L -4.0 -1.5 ---- ---- 18.0 1.82 24.8 ---- 31.0 4.98 43.8 21.0 ---- -1.5 ---- ---- 0.02 0.00 18.9 ---- 0.05 0.00 34.9 LG ---- -1.5 ---- ---- 18.0 0.20 18.9 ---- 31.0 0.54 34.9 3.0 ---- 2.0 -5 5 0.03 1.52 17.2 5 0.08 1.52 32.8 4 4 6.00 3RS -__- 2.0 -5 5 13.0 0.52 17.2 5 26.0 1.88 32.8 150 5 1.101 11.0 - 8.0 -----0.03 2.60 14.1 ---0.11 2.60 28.3 ' S 5 2.00 150 10 1.101 6 10 8.00 150 11 0.874 7 11 59.50 150 12 0.874 8 12 6.00 150 13 0.874 C ---- 8.0 ---- ---- 13.0 0.09 14.1 ---- 26.0 0.33 28.3 1.0 ---- 10.0 ---- ---- 0.03 0.87 13.1 ---- 0.11 0.87 27.1 LR ---- 10.0 ---- ---- 13.0 1.23 13.1 -- 26.0 4.42 27.1 5.0 ---- 10.0 ---- ---- 0.09 0.00 11.9 ---- 0.34 0.00 22.7 B5R ---- 10.0 ---- ---- 6.6 1.79 11.9 ---- 12.9 6.30 22.7 8.0 ---- 10.0 ---- ---- 0.03 0.00 10.1 ---- 0.09 0.00 16.4 B ---- 10.0 ---- ---- 0.0 0.00 10.1 ---- 0.0 0.00 16.4 3.0 ---- 10.0 ---- ---- 0.00 0.00 10.1 ---- 0.00 0.00 16.4 9 12 78.00 LB9R ---- 10.0 ---- ---- 6.6 2.50 10.1 ---- 12.9 8.77 16.4 150 14 0.874 16.0 ---- 10.0 4.71 13.0 0.03 0.00 7.6 13.0 0.09 0.00 7.6 10 14 5.50 B ---- 10.0 4.71 13.0 -6.4 0.22 7.6 13.0 -0.1 0.00 7.6 150 15 0.874 3.0 ---- 10.0 4.71 ---- -0.03 0.00 7.8 13.0 0.00 0.00 7.6 11 15 80.50 LB9R ---- 10.0 4.71 ---- -6.4 2.49 7.8 13.0 -13.1 9.21 7.6 150 16 0.874 16.0 ---- 10.0 ---- ---- -0.03 0.00 10.3 ---- -0.10 0.00 16.8 12 16 50.50 2B5R ---- 10.0 ---- ---- -6.4 1.59 10.3 ---- -13.1 5.87 16.8 150 11 0.874 11.0 ---- 10.0 --- -0.03 0.00 11.9 - -- -0.10 0.00 22.7 Legend: P - Pipe # DIA - Pipe Diameter EQV. LN - Pipe Equivalent Length PUMP - Pump Pressure SP - K-Factor FLOW - Flow Rate PF - Pressure Loss due to Friction PT - Total Pressure at Node Node Notes Pipe Notes LEN - Pipe Length FIT. - Pipe Fittings FIXD LOSS - Fixed Loss Device EL - Node Elevation DISCH - Discharge in gpm FL/FT - Friction Loss per Foot PE - Pressure Loss due to Elevation DATE: 3/12/2014 S:\2014\31197\C?'�\PLAN 3771.rdf 11'-) Page 3 Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X, The maximum velocity of water flow occurs in pipe 1 at 7.42 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 6 at 13.90 ft/s with 2 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt PAGE: C MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.874 1.00 4.00 3.00 1.00 1.00 5.00 2.00 0.00 0.00 0.00 1.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 PAGE: K MATERIAL: Copper Tube-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.995 1.00 2.00 6.00 2.00 2.00 6.00 0.00 0.00 0.00 0.00 PAGE: L MATERIAL: Copper Tube-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.265 1.00 3.00 6.00 2.00 2.00 7.00 0.00 0.00 0.00 0.00 PAGE: P MATERIAL: PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.360 2.00 7.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.2 computer program (License No. 500814.44 ) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.05 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.05 gpm with 2 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 DATE: 3/12/2014 S:\2014\31197\C1�\PLAN 3771.rdf ^1 Page 4 WATER SUPPLY CURVE 75.0 67.5 -B r I 0.0 04 8 12 16 20 24 28 32 36 40 FLOW (GPM) Static = 72.0 psi, Residual = 18.0 psi @ 1500 gpm (1 sprinkler flowing) (2 sprinklers flowing) A = Available Water Supply C = Available Water Supply 72.0 psi @ 18.0 gpm 72.0 psi @ 31.0 gpm B = Required Water Supply D = Required Water Supply 28.0 psi @ 18.0 gpm 52.8 psi @ 31.0 gpm DATE: 3/12/2014 S:\2014\31197\('— C\PLAN 3771.rdf I,-) Page 5 DATE: 3/12/2014 S:\2014\31197\r_)F\PLAN 3771.rdf '� Page 1 FIRE SPRINKLER SYSTEMS 705 E. HARRISON, SUITE 200 CORONA,CA 92879 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR BELMONT COLLECTION "PLAN 3771" LA QUINTA, CA TRACT 32879 10% TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN CALC AREA 2 Date: 3/12/2014 File No: 31197 Data File Name: PLAN 3771.rdf SPRINKLER SPACING 400.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 20.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 10.0 ft. SPRINKLER SPECIFICATIONS Mfr: Viking Descr: VK457 Conc.Pend.(20x20) K=4.90 Calculated K Factor for Arm-Overs & Drops: 1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee) 0.0 ft. x 0.874 in. Arm -Over: K=4.67 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 72.0 psi Resid: 18.0 psi F1ow:1500.0 gpm Public Main Size: 8 in Domestic Demand: 5.0 gpm at node number 4 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press. Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 20.0 18.0 13 25.0 72.0 49.6 1 20.0 18.0 13 25.0 72.0 49.6 REVIEWING AUTHORITY RIVERSIDE COUNTY FIRE DEPARTMENT DATE: 3/12/2014 S:\2014\31197\('�C\PLAN 3771.rdf Page 2 RESULTS OF ANALYSIS PIPE & NODE DATA * FLOW ANALYSIS * 1 sprinkler flowing * 1 sprinklers flowing FIXD P # END LEN FIT. LOSS EL SP *DISCH FLOW PF PT *DISCH FLOW PF PT HWC NOD DIA EQV.LN PUMP (FT) (K) *(GPM) FL/FT PE (PSI)*(GPM) FL/FT PE (PSI) 1 1 30.00 B ---- -1.5 SRCE ---- 25.0 6.05 49.6 ---- 25.0 6.06 49.6 150 2 0.995 6.0 ---- -1.5 ---- ---- 0.17 0.00 43.5 ---- 0.17 0.00 43.5 2 2 70.00 31, -4.0 -1.5 ---- ---- 25.0 3.34 43.5 ---- 25.0 3.34 43.5 150 3 1.360 21.0 ---- -1.5 ---- ---- 0.04 0.00 36.2 ---- 0.04 0.00 36.2 3 3 4.00 LG ---- -1.5 ---- ---- 25.0 0.37 36.2 ---- 25.0 0.37 36.2 150 4 1.265 3.0 ---- 2.0 -5 5 0.05 1.52 34.3 5 0.05 1.52 34.3 4 4 6.00 3RS ----- 2.0 -5 5 20.0 1.16 34.3 5 20.0 1.16 34.3 150 5 1.101 11.0 ---- 8.0 ----- ---- 0.07 2.60 30.5 ---- 0.07 2.60 30.5 5 5 2.00 C -- - 8.0 ---- ---- 20.0 0.20 30.5 ---- 20.0 0.20 30.5 150 10 1.101 1.0 ---- 10.0 ----- ---- 0.07 0.87 29.5 ---- 0.07 0.87 29.5 6 10 8.00 150 11 0.874 7 11 59.50 150 12 0.874 8 12 6.00 150 13 0.874 LR ---- 10.0 ---- ---- 20.0 2.72 29.5 ---- 20.0 2.72 29.5 5.0 ---- 10.0 ---- ---- 0.21 0.00 26.7 ---- 0.21 0.00 26.7 B5R ---- 10.0 ---- ---- 13.5 6.83 26.7 ---- 13.5 6.83 26.7 8.0 ---- 10.0 ---- ------ 0.10 0.00 19.9 --- 0.10 0.00 19.9 B ---- 10.0 ---- -- 20.0 1.88 19.9 ---- 20.0 1.88 19.9 3.0 ---- 10.0 4.71 20.0 0.21 0.00 18.0 20.0 0.21 0.00 18.0 9 12 78.00 LB9R -- 10.0 ----- ---- -6.5 2.46 19.9 ---- -6.5 2.46 19.9 150 14 0.874 16.0 ---- 10.0 ---- ---- -0.03 0.00 22.4 ---- -0.03 0.00 22.4 10 14 5.50 B - 10.0 ---- ---- -6.5 0.22 22.4--- -6.5 0.22 22.4 150 15 0.874 3.0 ---- 10.0 ---- ----- -0.03 0.00 22.6 ---- -0.03 0.00 22.6 11 15 80.50 LB9R ---- 10.0 ---- ---- -6.5 2.53 22.6 ---- -6.5 2.53 22.6 150 16 0.874 16.0 ----- 10.0 --- -0.03 0.00 25.1 ---- -0.03 0.00 25.1 12 16 50.50 2B5R ---- 10.0 ---- ---- -6.5 1.61 25.1 --- -6.5 1.61 25.1 150 11 0.874 11.0 ---- 10.0 ---- ---- -0.03 0.00 26.7 ---- -0.03 0.00 26.7 Legend: P - Pipe ## DIA - Pipe Diameter EQV. LN - Pipe Equivalent Length PUMP - Pump Pressure SP - K-Factor FLOW - Flow Rate PF - Pressure Loss due to Friction PT - Total Pressure at Node Node Notes Pipe Notes LEN - Pipe Length FIT. - Pipe Fittings FIXD LOSS - Fixed Loss Device EL - Node Elevation DISCH - Discharge in gpm FL/FT - Friction Loss per Foot PE - Pressure Loss due to Elevation DATE: 3/12/2014 S:\2014\31197\(-)C\PLAN 3771.rdf Page 3 Fitti,eg Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X, The maximum velocity of water flow occurs in pipe 8 at 10.70 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 6 at 10.70 ft/s with 1 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt PAGE: C MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.874 1.00 4.00 3.00 1.00 1.00 5.00 2.00 0.00 0.00 0.00 1.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 PAGE: K MATERIAL: Copper Tube-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.995 1.00 2.00 6.00 2.00 2.00 6.00 0.00 0.00 0.00 0.00 PAGE: L MATERIAL: Copper Tube-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.265 1.00 3.00 6.00 2.00 2.00 7.00 0.00 0.00 0.00 0.00 PAGE: P MATERIAL: PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.360 2.00 7.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.2 computer program (License No. 50081444 ) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.10 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.02 gpm with 1 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 DATE: 3/12/2014 S:\2014\31197\r)C\PLAN 3771.rdf !, Page 4 0 75.0 67.5 P 60.0 R E 52.5 S S 45.0 U R 37.5 E 30.0 f i P 22.5 S I 15.0 I 7.5 0.0 � I — i 04 8 12 16 WATER SUPPLY CURVE C 20 24 28 32 FLOW (GPM) 36 40 Static = 72.0 psi, Residual = 18.0 psi @ 1500 gpm (1 sprinkler flowing) (1 sprinklers flowing) A = Available Water Supply C = Available Water Supply 72.0 psi @ 25.0 gpm 72.0 psi @ 25.0 gpm B = Required Water Supply D = Required Water Supply 49.6 psi @ 25.0 gpm 49.6 psi @ 25.0 gpm �iATL�R ,$mil Residential Connection Charge Estimate Date: April 21, 2014 Customer Name: Lennar. Homes, Inc. Parcel No. 767-790-055 Address: 81305 Storm Cat Crt, La Quinta Phone No. Geo. LID: 669366 (951) 817-3526 06-07-15-2 Block No. Lot No. 216 Size of Lot: 23,522 sq. ft. Tract No. 32879 Type of Service: R-1: Duplex: ❑ Triplex: ❑ Apts: ❑ SWK: $ - Acres: 0 SWSC: $12,218.00 /acre WSBFC: $ 3,707.00 r SCC: $ 4,851.00 Treatment: $2,395/edu Collection: $1,836/edu Meter: $ 400.00 Meter Size: I inch Meter surcharge: $ 2,479.00 Service Size: 1 inch Service: $ - Meter & Service: $ - Backflow: $ Other: -$ - (see explanation below) Sewer Lateral: $ - Total: $ 11,437.00 Other. Abandon / Relocate Information Supplied By Customer CVWD System Data Domestic Water Demand' Max. Flow= Min. Pressure= Fire Sprinkler Demand* Max. Flow= Min. Pressure= 5jMtempe: Multi 15-20 gpm 60 psi 31.5 gpm 49 psi Stand Alone ❑ * CVWD USES WORST CASE CONDITION Service Connection** Max. Flow*= 31.5 gpm Inlet Pressure = 77 psi Outlet Pressure= 51 psi Meter Size = 1 inch Service Size= 1 inch *• For Calculation Purposes- Service Connection Includes: Service Connection Pipe=50', Meter Stop, Meter, Check Valve & Shut Off Valve Notes: Tract No. 32879, Griffin Ranch, Phase 113-213 conists of 9.44 acres. The SIWSC will be charged on the first meter requested in this phase, which is Lid 669372, PZ 14-5311. Per Construction Dwg. No. 35207 there is an existing 1" service and per Dwg. No. 35215 there is a sewer lateral. E-mail Invoice to: larry.liebel@lennar.com & ulrich ----- PZ 14-5414 Technician: Sandra Villalobos a _.. Approved by: ``�;r Date: �.1 / 31 ......Kral _ . cvwd-950 *********This is iust a QUOTE. all fees are subiect to Chanvre********* 11/11 PROUDLY SERVING THE UNINCORPORATED AREAS OF RIVERSIDE COUNTY AND THE CITIES OF: BANNING BEAUMONT CALI M ESA CANYON LAKE COACHELLA DESERT HOT SPRINGS EASTVALE INDIAN WELLS INDIO J U R U PA VALLEY LAKE ELSINORE LA QUINTA MENIFEE MORENO VALLEY NORCO PALM DESERT PERRIS RANCHO MIRAGE RUBIDOUx CSD SAN JACINTO TEMECULA WILDOMAR BOARD OF SUPERVISORS: KEVIN JEFFRIES DISTRICT 1 JOHN TAVAGLIONE DISTRICT 2 JEFF STONE DISTRICT 3 I(�IHN BENOIT DISTRICT 4 N`ARION ASHLEY DISTRICT 5 RIVERSIDE COUNTY FIRE EPARTMENT IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION 77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 92211-4131 • Phone (760) 863-8886 • Fax (760) 863-7072 www.rvefire.org April 30t1i,2014 Fire Sprinkler Systems 705 E. Harrison Street,Ste.# 200 Corona, CA 92879 Re: Residential Fire Sprinkler Plan Review LAQ-I4-RS-031, Belmont Lot 216, 81-305 Storm Cat Ct. La Quinta, CA The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department Planning & Engineering personnel and are approved with the following conditions. A minimum of three spare fire sprinklers of each type and temperature rating along with a sprinkler wrench should be located in a spare cabinet at the system riser or other approved location. Permanently marked identification signs shall be attached to all control valves. A warning sign, with minimum'/ inch letters, shall be affixed adjacent to the main shutoff valve and shall state the following: WARNING: The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a fire sprinkler system, such as water softeners, filtration systems, and automatic shut-off valves, shall not be added to the system without a review of the fire sprinkler system by a fire protections specialist. DO NOT remove this sign. The following inspections/tests are required to be witnessed by the Fire Department Planning Division Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure (b) Final inspection The Fire Department job card, approved plans and condition letter must be at the job site or NO inspection will be performed. Applicant/installer shall be responsible to contact the Fire Department to schedule inspection(s) a minimum of 72 hours prior to the requested inspection date. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering Staff at (760) 863 8886. Sincerely, Lisa Nottingham, Fire Safety Specialist PROUDLY SERVING THE UNINCORPORATED AREAS OF RIVERSIDE COUNTY AND THE CITIES OF: BANNING BEAUMONT CALI M ESA CANYON LAKE COACHELLA DESERT HOT SPRINGS EASTVALE INDIAN WELLS INDIO JURUPA VALLEY LAKE ELSINORE LA QUINTA MENIFEE MORENO VALLEY NORCO PALM DESERT PERRIS RANCHO MIRAGE RUBIDOUx CSD SAN JACINTO TEMECULA WILDOMAR BOARD OF SUPERVISORS: KEVIN JEFFRIES DISTRICT 1 JOHN TAVAGLIONE DISTRICT 2 JEFF STONE DISTRICT 3 JOHN BENOIT DISTRICT 4 MARION ASHLEY DISTRICT 5 RIVERSIDE COUNTY FIR; DEPARTMENT IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION 77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 92211-4131 • Phone (760) 863-8886 ■ Fax (760) 863-7072 www.rvcfire.org March 28, 2014 Fire Sprinkler Systems 705 E. Harrison St. #200 Corona, CA Re: Residential Fire Sprinkler Review LAQ-I4-RS-031 Belmont 81-305 Storm Cat Ct. Lot 216 La Quinta, CA The Riverside County Fire Department Planning & Engineering personnel have reviewed your sprinkler plans for the above referenced project. Please be advised that your plans require the following corrections: Please provide the following information in your next submittal: 1) Provide a recent (within 6 months) Residential Connection Charge Estimate form from CWVD. NO inspections will be performed until Riverside County Fire Department Planning & Engineering staff has approved the corrected plans. All questions regarding the meaning of these conditions should be referred to the Riverside County Fire Department Planning & Engineering staff at (760) 863-8886. Sincerely, '�7. SA"I, Jason Stubble Fire Safety Specialist Otero, Stephen@CALFIRE Subject: LAQ-I4-RS-031 - GRIFFIN RANCH/PIMLICO LOT 216 - RES SPK FINAL Location: 81305 STORM CAT COURT LOT 216, LA QUINTA Start: Tue 7/22/2014 2:30 PM End: Tue 7/22/2014 3:00 PM Recurrence: (none) Organizer: Hetrick, Kohl@CALFIRE Rep. Name: Phone#: Cell#: Co. Name: HYDRANT SYSTEM PASS I FAIL FIRE ALARM PASS FAIL Thrust block pre -pour Rou h-wire inspection Underground rough Function test Under round hydro Duct detectors/velocity Flush 24 hr. battery test Final Sprinkler monitoring SPRINKLER U.G. Final Thrust block pre -pour SPECIAL SUPPRESSION Underground rough Door fan test Underground hydro Abort test Flush Mechanical shutdown Final Detector test FIRE SPRINKLER Delu e/ re -action Weld inspection Final Overhead rough piping UST/AST TANK Overhead hydro Installation UG flush / OK to connect Removal Main drain/Inspect. Test Emergency shut off High pile storage Primary piping In-racksprinklers Secondary piping Hose racks Dispensers & shear valves X Final Final KITCHEN HOOD EXTINGUISHING MISC. INSPECTION Detections stem Spray booths Function Test Hood/duct extin uishin Gas/Electrical shut-off High pile rack storage Nozzle model/placement H.P. vents/access/corridors Fire alarm connection Tract access/hvdrant verification Final Other: SPRAY BOOTHS KNOX SYSTEM Installation Building Knox box Air flow test Gate access Knox box/padlock Mechanical interlock BUILDING INSPECTIONS Extinguishing system T/I final Fire alarm connection Shell final Final Final for occupancy Start Time: ; aQ Finish Time: Start Time: Finish Time: 1 Stubble, Jason@CALFIRE Subject: LAQ-I4-RS-031 - BELMONT - LOT#216 - O.H. ROUGH Location: 81305 STORM CAT COURT, LOT#216, LA QUINTA Start: Fri 5/2/2014 9:00 AM End: Fri 5/2/2014 9:20 AM Recurrence: (none) Organizer: Stubble, Jason@CALFIRE Rep. Name: Jr Phone#: 951-733-0485 Cell#: Co. Name: FSS CrossSt: HYDRANT SYSTEM PASS FAIL FIRE ALARM PASS FAIL Thrust block pre -pour Rough -wire inspection Under round rough Function test Underground hydro Duct detectors/velocity Flush 24 hr. battery test Final Sprinkler monitoring SPRINKLER U.G. Final Thrust block pre -pour SPECIAL SUPPRESSION Underground rough Door fan test Under round hydro Abort test Flush Mechanical shutdown Final Detector test FIRE SPRINKLER Deluge/pre-action Weld inspection Final X Overhead rough piping UST/AST TANK Overhead hydro Installation UG flush / OK to connect Removal Main drain/Ins ect. Test Emer e 2Y shut off High pile storage Primary piping In-racksprinklers Secondary piping Hose racks Dispensers & shear valves Final Final KITCHEN HOOD EXTINGUISHING MISC. INSPECTION Detections stem Spray booths Function Test Hood/duct extinguishing Gas/Electrical shut-off High pile rack storage Nozzle model/placement H.P. vents/access/corridors Fire alarm connection Tract access/hydrant verification Final I Other: SPRAY BOOTHS KNOX SYSTEM Installation Building Knox box Air flow test Gate access Knox box/padlock Mechanical interlock BUILDING INSPECTIONS Extinguishing system T/I final Fire alarm connection Shell final Final N4 1,S)k.. Final for occupancy Start Time: I VOW I Finish Time: Start Time: I I Finish Time: 1 Riverside County Fire Department Fire Protu-tion Planning Section Riverside Office: 2300 Market St., Ste. 150, Riverside, CA 92501 Ph. (951) 955-4777 Fax (951) 955.4886 Murriela Office: 39493 Los Alamos Rd., Ste A, Murriela, CA 92563 Ph. (951) 600-6160 Fax (951) 600-6164 Palm Desert Office: 77-933 Las Montanas Rd., # 201 Palm Desert, CA 92211-41 31 Ph- (760) 863-8886 (760) 863-7072 Fire Department Clearance/Release Date: -q - 2�-- ��A To: La D �r 1��► ��Q Fax: Tract/Parcel Map #: Permit/Lot #: LAD - N Job Site Address: 3 JS S ���M (AC-:� v LA OU A > ��),53 Final For Recordation Release For Building Permit(s) Shell Final Only (No Tenant) Final ForOceupano� SQC,K-1I025-5 Building Plan Check Fees Paid Building Plan Check Fees Not Paid Other Fees Fees Not Required If you should have any questions, please contact the appropriate Riverside County Fire Protection Planning office for further assistance. 1, Authorizing Signature For Release Print Name Farm C — Revised 1/15/2014 Riverside County Fire Depurtment Riverside Office: 2300 Market Street, Ste. 150 Riverside, CA 92501 Phone: (951) 955-4777 - Fax: (951) 955-4886 PLAN REVIEW FORM 0 New C] Re -Submittal # 1 D As-buiilts Perm "64-61 _ Lk • Address: Iil. t- i City & Zip: Qri J Fire Protectlon Planning Palm Desert Office: 77-933 Las Montanas Rd., Ste 201 Palm Desert CA 92211 Phone: (760) 863-8886 - Fax: (760) 863-7072 Office Use Only RECEIVED APR 2 2 2014 RNERSWE COUNn MM Mo7wHON PLANMG P"tMi&W I have read and understand that Fire Dept. fees are Deposit Based Fees and there may be additional money due prior to or after project final. Sign: �-<D _ /J . V , Print: Y DESCOTEAUX Can#at, CONTACT PERSON: AMY DESCOTEAUX BILL TO: FIRE SPRINKLER SYSTEMS, INC. Mailing Address: 705 E. HARRISON ST., SUITE 200 Mailing Address: City & Zip CORONA, CA 92879 City & Zip Phone No.: 800-915-3473 Fax:951-272-2535 Phone No.: Email: AMYD@FIREINC.NET Email: Fax: The person listed on "Billing Information" will receive ALL billing, correspondence and refunds for any work billed to this aermit. Any changes in billing information must be made in writing to our office. _ ❑ Commercial O Industrial ntial ❑ Special Event ❑ Other ,p Building ❑ Building Tenant Improvement ❑ High Fire Area ❑ Underground Water D,Sprinkler System ❑ TI Sprinkler System El Sprinkler Monitoring O Fire Alarm System d Hood & Duct Suppression System ❑ Other Suppression System ❑ Spray Booth ❑ Cell Site ❑ High Pile/Racks ❑ Other: Story - a Tank Submittals: D Dispensers Only ❑ Above Ground ❑ Underground n Fee Paid: Reviewed b . - Date Paid: ` PC Review Date: Check#: 0 Approved ❑ Denied Received By: Plans Stamped: ❑Yes ONO Letter Attached: ❑Yes ONO Receipt#(OCR) Job Card Included: DYes ❑NO Called for Pick -Up Date: By: Picked -Up Date: 5 i . I By: Shipped By / Method Form 1 - Revised I OnW20I0 Visit us at www.rvcfire.ora T., Riverside County Fire Depu-tment� Riverside Office: 2300 Market Street, Ste. 150 Riverside, CA 92501{ Phone: (951) 955-4777 - Fax: (951) 955-4886 PLAN REVIEW FORM El New ❑ Re -Submittal # ❑ As-builts Permit No.,6,-12s - U-5 1 Project Information (Please Print) BELMONT / TRACT 32879 / PLAN 4 MODEL Tire Protection Planning Palm Desert Office: 77-933 Las Montanas Rd., Ste 201 Palm Desert CA 92211 Phone: (760) 863-8886 - Fax: (760) 863-7072 Office Use Only Z Tfi Plans Received Project Name: I have read and understand that Fire inept, fees are LOT 216 / 81-305 STORM CAT COURT Deposit Based Fees and there may be additional Address: money due t❑ or after project final. LA QUINTA Sign: City & Zip: Print: Y SCOTEAUX Contact Information Billing Information --_J�ame as Contact Info CONTACT PERSON: AMY DESCOTEAUX BILL TO: FIRE SPRINKLER SYSTEMS, INC. Mailing Address: 705 E. HARRISON ST., SUITE 200 Mailing Address: City & Zip CORONA, CA 92879 City & Zip Phone No.: 800-915-3473 Fax:951-272-2535 Phone No.: Fax: Email: AMYD@FIREINC.NET Email: The person listed on "Billing Information" will receive ALL billing, correspondence and refunds for any work billed to this permit. Any changes in billing information must be made in writing to our office. rlan Review Type IUneck appropnate Items) ❑ Commercial ❑ Industrial El Residential ❑ Special Event ❑ Other ❑ Building ❑ Building Tenant Improvement ❑ High Fire Area ❑ Underground Water El Sprinkler System ❑ TI Sprinkler System ❑ Sprinkler Monitoring Q Fire Alarm System ❑ Hood & Duct Suppression System ❑ Other Suppression System ❑ Spray Booth ❑ Cell Site 0 High Pile/Racks ❑ Other: Storage Tanlc Submittals: ❑ Dispensers Only ❑ Above Ground ❑ Underground 7ffICP Ilse Fee Paid: .ems S Called for Pick -Up Reviewed by: Date Paid: -3 PC Review Date: Z ( Date: By: l 7G Check#: ;7-94 77 7 ❑ Approved 16 Denied Picked -Up Received By: Plans Stamped: ❑Yes [19NO Date: By: Letter Attached: ®Yes ❑No Receipt#(OCR) Job Card Included: ❑Yes ®No Shipped By / Method Form 1 — Revised 10/27P2010 Visit us at www.rvcfire.or