LAQ-14-RS-033 Pimlico Plan 1ADDITIONAL SITES
CHRONOLOGY
CONTACTS
CONDITIONS
Description: 4,036SF DWELLING/VB/RES-3/CLASS A-FR/13D
Type: BUILDING, RESIDENTIAL Subtype: DWELLING - SINGLE
FAMILY DETACHED
Status: FINALED Applied: 12/17/2013
Parcel No: 767320999 Site Address: 81280 STORM CAT CT LA QUINTA,CA 92253 Approved: 3/18/2014
Subdivision: Block: Lot: Issued:
Lot Sq Ft: Building Sq Ft: Zoning: Finaled:
Valuation: $0.00 Occupancy Type: Construction Type: Expired:
No. Buildings: No. Stories: No. Unites:
Details: AFTER BEING RE-CONVERTED FROM A MODEL HOME TO THE ORIGINAL SINGLE FAMILY DWELLING THIS PERMIT WAS FINALIZED PER
BSPN2017-0023.
RIVERSIDE COUNTY FIRE PERMIT #LAQ-14-RS-033. SEE FIRE FOLDER.
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
ART IN PUBLIC PLACES-
RES 27000003650500 $154.98 $154.98 3/25/14
Total Paid for ART IN PUBLIC PLACES-RES: $154.98 $154.98
BLDG PC 200K-1M 10160003428200 $1,294.24 $1,294.24 3/25/14
Total Paid for BLDG PC 200K-1M: $1,294.24 $1,294.24
BLDG STDS ADMIN
(SB1473)10100002030600 $11.00 $11.00 3/25/14
Total Paid for BLDG STDS ADMIN (SB1473): $11.00 $11.00
Printed: Wednesday, February 28, 2024 2:51:45 PM 1 of 5
Permit Details
City of La Quinta
PERMIT NUMBER
SFD-13-1628
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
DIF CIVIC CENTER - RES 25200003650000 $942.00 $942.00 3/25/14
Total Paid for DIF CIVIC CENTER - RES: $942.00 $942.00
DIF COMMUNITY
CENTERS-RES 25400003650000 $129.00 $129.00 3/25/14
Total Paid for DIF COMMUNITY CENTERS-RES: $129.00 $129.00
DIF FIRE PROTECTION-
RES 25700003650000 $433.00 $433.00 3/25/14
Total Paid for DIF FIRE PROTECTION-RES: $433.00 $433.00
DIF LIBRARIES - RES 25300003650000 $344.00 $344.00 3/25/14
Total Paid for DIF LIBRARIES - RES: $344.00 $344.00
DIF PARK MAINT FAC -
RES 25600003650000 $40.00 $40.00 3/25/14
Total Paid for DIF PARK MAINT FAC - RES: $40.00 $40.00
DIF PARKS/REC - RES 25100003650000 $2,048.00 $2,048.00 3/25/14
Total Paid for DIF PARKS/REC - RES: $2,048.00 $2,048.00
DIF STREET MAINT FAC-
RES 25500003650000 $116.00 $116.00 3/25/14
Total Paid for DIF STREET MAINT FAC-RES: $116.00 $116.00
DIF TRANSPORTATION -
RES 25000003650000 $2,842.00 $2,842.00 3/25/14
Total Paid for DIF TRANSPORTATION - RES: $2,842.00 $2,842.00
MULTI-SPECIES
(MSHCP) FEE 10100002031000 $1,278.00 $1,278.00 3/25/14
Total Paid for MULTI-SPECIES (MSHCP) FEE: $1,278.00 $1,278.00
PERMIT FEES 0 $608.15 $608.15 3/25/14
PERMIT FEES 0 $191.64 $191.64 3/25/14
Printed: Wednesday, February 28, 2024 2:51:45 PM 2 of 5
Permit Details
City of La Quinta
PERMIT NUMBER
SFD-13-1628
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED
DATE
COMPLETED
DATE
RESULT REMARKS NOTES
PLUMBING 2013 - SEWER
CONNECTION KIRK KIRKL 4/1/2014 4/1/2014 APPROVED
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
PERMIT FEES 0 $309.86 $309.86 3/25/14
PERMIT FEES 0 $369.51 $369.51 3/25/14
Total Paid for PERMIT FEES: $1,479.16 $1,479.16
PLAN CHECK,
ELECTRICAL 10160003428200 $67.23 $67.23 3/25/14
Total Paid for PLAN CHECK, ELECTRICAL: $67.23 $67.23
PLAN CHECK,
MECHANICAL 10160003428200 $181.14 $181.14 3/25/14
Total Paid for PLAN CHECK, MECHANICAL: $181.14 $181.14
PLAN CHECK,
PLUMBING 10160003428200 $340.90 $340.90 3/25/14
Total Paid for PLAN CHECK, PLUMBING: $340.90 $340.90
PLAN CHECK, SFD
GRADING 10160003428200 $143.00 $143.00 3/25/14
Total Paid for PLAN CHECK, SFD GRADING: $143.00 $143.00
STRONG MOTION (SMI)
- RES 10100002030800 $26.20 $26.20 3/25/14
Total Paid for STRONG MOTION (SMI) - RES: $26.20 $26.20
TUMF: RESIDENTIAL 22400002032000 $1,837.44 $1,837.44 3/25/14
Total Paid for TUMF: RESIDENTIAL: $1,837.44 $1,837.44
TOTALS:$13,707.29 $13,707.29
Printed: Wednesday, February 28, 2024 2:51:45 PM 3 of 5
Permit Details
City of La Quinta
PERMIT NUMBER
SFD-13-1628
BOND INFORMATION
PLUMBING 2013 -
UNDERGROUND
PLUMBING
KIRK KIRKL 4/1/2014 4/1/2014 APPROVED
BUILDING 2013 -
FOOTINGS KIRK KIRKL 4/30/2014 4/30/2014 APPROVED
BUILDING 2013 - OKAY TO
WRAP KIRK KIRKL 4/30/2014 4/30/2014 APPROVED
BUILDING 2013 - SLAB KIRK KIRKL 4/30/2014 4/30/2014 APPROVED
BUILDING 2013 -
FRAMING KIRK KIRKL 5/16/2014 5/16/2014 APPROVED
BUILDING 2013 - LATH KIRK KIRKL 5/21/2014 5/21/2014 APPROVED
BUILDING 2013 -
DRYWALL NAIL KIRK KIRKL 5/22/2014 5/22/2014 APPROVED
PLUMBING 2013 -
SHOWER PAN KIRK KIRKL 5/22/2014 5/22/2014 APPROVED
PLUMBING 2013 - GAS
LINE / GAS TEST KIRK KIRKL 6/12/2014 6/12/2014 APPROVED
ELECTRICAL 2013 - TEMP
USE OF PERMANENT
POWER
KIRK KIRKL 6/24/2014 6/24/2014 APPROVED
FINAL**KKI 8/20/2014 8/20/2014 APPROVED
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED
DATE
STATUS REMARKS NOTES
PARENT PROJECTS
Printed: Wednesday, February 28, 2024 2:51:45 PM 4 of 5
Permit Details
City of La Quinta
PERMIT NUMBER
SFD-13-1628
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 11/21/2017 JAKE FUSON CERTIFICATE OF
OCCUPANCY
SFD-13-1628 -
CERTIFICATE OF
OCCUPANCY.pdf
1
Printed: Wednesday, February 28, 2024 2:51:45 PM 5 of 5
Permit Details
City of La Quinta
PERMIT NUMBER
SFD-13-1628
January 13, 2012 Sprinkler 149m 13DICRC 313.3 GENERAL NOTES
FREEDOM" RESIDENTIAL February3.2012 Sprinkler 147u o X M �
w
+ e • PENDENT SPRINKLER wa.ldwd. HIGHWAY 111 Gi cJ7
FREEDOW- RESIDENTIAL c�,�sa www.ryca-1leoom 1. AUTOMATIC FIRE SPRINKLER SYSTEM HAS BEEN DESIGNED TO BE _ DR. CARREU BLVD
F=rm Protection
w4j VK468 (K4.9) ■ • ~- CONCEALED PENDENT INSTALLED IN ACCORDANCE WITH NFPA 13D, 2013 EDITION AND THE
The Viking Corporation, 214 N Industrial Park Drive, Hastings iVfl 49058 SPRINKLER VK457 (K4.9] REQUIREMENTS OF RIVERSIDE COUNTY FIRE DEPARTMENT.
Telephone: 2b994rs-9501 Technical Services; 877-384-54Sd Fax: 2 9-818-168b Errrail: techsvcs@vikingcorp.cartl Models BBy SDp "� F.. andAP 2. THIS SPRINKLER SYSTEM SHALL BE TESTED AND INSPECTED BOTH AVENUE 4-8
The liking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 "SPOt"IG ApAIkefian SpfiinkiLrs THE ROUGH AND FiNAL INSPECTION PRIOR TO OCCUPANCY BEING
GRANBE
I. DESCRIPTION Telephone: 269-9455501 Technical Services: 877-384.5464 Fax: 269-818-1660 Email: techsvcs@vikingcorp-corn Farr�r�te�l[ ngAttil"" NOTIFIED
Ed_ THE JURISDICTIONAL WORFIRKING
PREVENTION OFFICE WILL E
Viking FresdorrP Residential Pendent Sprinkler VK468 is a small, thermosensitive, glass- - 0 WORKING DAYS IN ADVANCE OF THE _
4
bulb residential sprinkler available in several different finishes and temperature ratings to _ f;J' 1. DESCRIPTION R° s - ff
AVENUE 9
. .. .. .. canon l: spm-LJ
REQUESTED
r � , . •. .. , � � k17rS apra�ale reef 5�pdnklare to t?& �r'�°°°m."•�m �,.�•,��+,..t.`m'.:
meet va in design requirements- The orifice design, with a K-Factor of 4.9 (70.8 metric?}, = Viking Freedoms Residential Concealed Pendent Sprinkler VK457 is a small o
ry 9 q 0 - '- _ D S�HJ�#�oA • Liumd rtpdandedcaversgeincam- =*":r 3. THE INSTALLER SHALL PERFORM ALL REQUIRED ACCEPTANCE TESTS,
allov�rs efficient use of available water supplies for the hydraulically designed fire -protection �J ` high-serlsilivity solder link and lever residential sprinkler designed for installation °an�la `dn°mrV,wr
system. The lass bulb operating element and special deflector characteristics meet the - . - _ T11e rYco tailored as (Back to Back),
5
9O Single DireGtior191], HIP, and AP tAt- r-v�ecais M1v $11ded in bothwet and AVENUE .� LU
Y g p 9 P - cn concealed pipe systems where the appearance of a smooth ceiling Is desired. x 1Cw �•SpeCIACAppdEceton3prinkala dry ��. 4. NOTCHING, DRILLING, OR OTHERWISE PENETRATING STRUCTURAL
g p The orifice design, with a K-Factor of 4.9 (70.6 metric''), allows the sprinlder's of = ` . Fur -male teeter, ror uw in woad MEMBERS SHALL BE iN ACCORDANCE WITH CALIFORNIA BUILDING CODE.
challenges of residential s rinkler standards.
1 ._ I ( g � .x,-- � � :?� Far Pmtxang PS(Ica' are tire aprlra0ere
I fcient use of available water supplies for the hydraulically designed Tire -protection '' = far combustible and rw-c uWbla truss canclruc+r0n.
�. LiST1NGSANE]APPR>'JVALS v... sloped atticspau&The Mad9lBaSIX ,LilatadrarepectfklrooslopesF-ew In
f system. The operating element and special deflector characteristics meetthe chat- and HiP am Spacft Application Aft 5. TYPE OF PLASTIC PIPE TO BE CPVC MANUFACTURED BY BLAZEMASTER
cULus Listed: Category VKr<W Spntvaw,pllc as Combustiblethe Model an -Is n mre dla � AVENUE 51
e I. d5 g ry � ,- lenges of residential sprinkler standards. ., .. .., ... �� 5pacthcAppldgafm Combustible Can- The sI?ad0p App6CtrtiOn Anlc spr6,- U.L. LISTED.
s S nkler havi c - L�
.: • ..... .. easier 3r,ac poi n9 min Ides pro,Ildethe heat level d prvtx
NYC Approved: MF� 89 g2-E, Vaiume 35 . j' The sprinkler is pre assembled with a threaded adapter for insta€latian With a law- _ eppacaoan a tmriatoritsuae,+sn+trar uon aria cwtao+ cost by eli hating --. z
profile small -diameter cover assembly installed flush to the ceiling. The two-piece Monet BR, SO, and HIP In aft spac Otewed foraddit-ar,ai aprinklerewld 6. ALL VALVES SHALL HAVE A PERMANENTLY AFFIXED SIGN INDICATING
NSF Certified: NSFIAN51 Standard 61, Drinking Water System Components >r ea d6cAppt>anonAtticsprinlaara brenc an. a anti In narycesee,an �j
Refer to the Approve[ Chart an page 1490 and Design Cr feria an page 149r for
design allows installation and testing of the sprinkler prior to installation of the p desu�riwtrepratacvonman attic can he sntirelt proued wkh '=:-=w . ITS FUNCTION. AVENUE 52
cover late. The "push -on'. "thread -off' design of the concealed cover late as i ° °ire' dry IgCatad he°" y.
p 9 p lard spray sPrtn da a cast savi tgs ere the peak or the roof using Modal BB. .
cULus Listing requirernenis that must be followed, - _ 7. PIPE SHALL BE HUNG FROM STRUCTURAL MEMBER PER THE UNIFORM
sembly allows easy installation of the covet- plate after the system has been tested _ i�':+• __ acr,ia,�m syetiabneting arenawns me- taacxto Back) spr:udrrs. It is M.
;
3. TECHNICAL DATA
and the ceiling finish has been applied, while also providing up to 2' (12.7 mm) of _ ~-� � la�borr•TTheSSppwiftAAMIJ04 nsprn- orWde Hulafflatbort IPsprinkRD l oneella `neolna� PLUMBING GODS, PIPE CLAMPS AND SCREWS ARE MANUFACTURED BY
iders tar Pnxecting Attics- have un- Berottheaelprr*lertype9 sautricent M. AFCON MFG. ARE U.L- LISTED AND ARE INSTALLED ACCORDING TO THE AVENUE 53
vertical adjustment. The cover assembly can be removed and reinstalled, allow- dargarie7,emost whwWveareiesl ateatcheraaMingcmwed.Foreoam- �`
Specifications: awperf0rmadforslopedatticspaces. pleandaeaur,,,ngtheuseofst °,a� HANGING REQUIREMENTS IN THEIR TECHNICAL DATA {SEE DETAIL}, �
Available since 2006. rig temporary removal of ceiling panels without taking the sprinkler system out of W They we UL Elated with that epeclfk: Spray Bprink(err, a syslent bt a BD loot w
Minimum operating Pressure. Refer to the Approval Chart service or removing the sprinkler. appraetlon 9L%dl:r141 ruseasspe- pa,3 Itch, tattle w10 d he 2 0 adl-
Maximum Wnrtting Pressure: 775 psi (12 bar), Factory tested hydrostatically to 500 psi (3d,5 bar). cialaprirklersaalJefnedbytheNFPA m�pitch, A13, edWthe2res -W 2:12 j8. THE SPACING AND LOCATION OF 513RIN3CLER5 SHALL CONFORM WITH
tsar of N!•Pa111S, ward req.l(re aeaen ,,.�::;.•-.;;:��,, THE MANUFACTURES REQUIREMENTS AND THOSE CONTAINED IN � AVENUE 54
TheS'pecificWi=lPnPdtirsprirF lnindlline9,acover tham6frtporkruf +� NFPA 13D, 2013 EDITION.
'2. LISTINGS AND APPROVALS llara provide on sarmnded age ftattic and aeveralsddmanafbranch-
spacing akwnmtive to the ralmdotaid ine6 to cover the hip areas. With the
w
V7 la1 w
ac. of StandaM 3-Wda/s.
3 inklary S Spray P^ - c A Ian Rttic
fdominak K-Factor: 4.9 U.S. (7p,6 merrier, u� cULus Listed: Category VKKYV � "a - �'� pd p`
tMetric K-hetarmeasurement shown is in Bar When pressureis measured in kPa. divide the metric Kfac:tcr shown by 10.0_ cV-111 Th■ n�^ gp�l^s$ a► smh d the mgLwWVowragecan beob+Alned 9. IF REQUIRED BY A.H.J. THE ALARM INDICATING DEVICE SHALL BE LISTED
Spray 9prlrtders used within attics ie wkh lust onsbranchline runr,lrg below AVENUE 55 Q
Refer to the Approval Chart on page 147w and Design Criteria on page 147x for cULus Listing requirements that must be FOR OUTSIDE SERVICE AND AUDIBLE FROM THE STREET THAT THE � � o
deSorihed in the 2007 edition d NFPA the peak am one down each dopa of
Glass -bulb fluid temperature rated to -65 'F (-55 °C) followed. 13. Table B.B.2.2 (aj and seeeon thehip beans, 7ha would rmuh Inap- HOUSE IS ADDRESSED ON. o
Overall Length: 2-1l4" (58 mm) e.s.4.1 4 praximateFr9l1%leaspipeneeded}ar a
InStalfbra,ola rNduCtlraththerum- : ' O ][ ❑
Material standards; bar ar bran Iv«te eaves a,a ewe at 10. SMOKE DETECTORS TO BE INSTALLED BY OTHERS. u: v N
3. TECHNICAL DATA the a m hen9e±a, arKiassa- - AIRPORT Bl_VD ¢
Frame Casting: Brass UNS C8440Q cu QM Brass Viking Technical Data may be found on elated lobar pliminsttng up to rive
y Specifications: bramhllnea 11. RESIDENTIAL CONCEALEO PENDENT SPRINKLERS ARE U.L. LiSTED AND tdDICi41
Deflector. Brass UNS G23000, Phosphor bronze UNS G51 U[)i0, or Brass The Viking Corporation's Web site at Available since 2G08. Anot w I mpbrtant aspeut of thespe- "; " ' MANUFACTURED BY VIKING. INSTALLED AT 16 FT. MAXIMUM SPACING
UNS-C26000 dec Ap rcatk,n N0, rinkertechnol-
P e to theA Approval Chart.[DATA).
• € Inc -corn_ Minimum Operating Prl=ssur�e Peter x SEE TECH. . _-..M.,'_::n.•,
Bulb: Glass, nominal 3 mm diameter Yiitp.livvwW.v kinggroup pe g pp rrrlwvlrrA,vr 1a tie redbCllnrl m eyamm vclurn& (
Always refer the Technkaal Uata
The Web site may Include a more resent Maximum Working Pressure.- 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). T awlllmetedo ado msY reauitm re-
BBlteville Spring Sealing Assembly: Nickel Alley, coated vn bath sides with s++ +�° �• vNSz air cornprex*
lhesin ofsdrypperallo-fd
Teflon Tape edition ofttlysTechnical Data Page. Thread Size' 1I2" (15 mm) NPT w4RNIxG'ihatPavd6scaxkvm aircomprels9prjandpasamysllcwf« 12. UPRIGHT INTERMEDIATE TEMP. QUICK RESPONSE SPRINKLERS U.L. °F..;'&...:.
wcmrespectfoherldNrlg6ndylatel quicker water de tknea,aimnatng LISTED AND MANUFACTURED BY TYCO INSTALLED AT 120 SQ.FT. SPACING
Nominal K-Factor: 4.9 U.S. 70-6 metric t
( ponnof �prfrtkder�+e>9rr98Ntl CA7>- the need for
Pip Cap and Insert Assembly Copper UNS-C11C30Q and Stainless Steel • Metric ltfactormeasurement shown is in par_ When pressure is measured in kPa, divide pddsnrs+mpropernarlavrnganefn- �� (SEE TECH. DATA}. VICINITY MAP
U N S-S30400 srerlaabn can permanendy damage
the metric K factor shown by 10.0. a aprlaver systrrn or Rs cwrpo 3x
Compression Screw Brass UNS-C36000 Material Standards: Vikin Technics€ Data may be found on nen(eaWctwae rlre�orfnhlermfap 13. PENDENT INTERMEDIATE TEMP. QUICK RESPONSE SPRINKLERS ARE U.L. I
Ordering information: {Also refer to the current Viking price list.) g y to ppwateinafremeverloaorcams LISTED AND MANUFACTURED BY VIKING INSTALLED AT 16 FT. MAX. SPACING N.T.S.
I
Sprinkler Body Brass UNS-C84400 or QM Brass The Viking Corporation's Wets site at rrroepe1°fAp"arr'a x (SEE TECH, DATA), ' "� • T • S • =� 4'' &
Sprinkler: Base Part No. 13637 Deflector: Phos tsar Bronze UNS-,C51000
Order Sprinkler VK468 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the tempera -
Deflector http:Ifuwfwvlkinggroupinc.com.
Deflector Pins: Stainless Steel UNS-S30200 The Web sate may Include a more recent °an""° c" p14. PENDENT SPRINKLERS ARE AT LEAST 3 ft. FROM OBSTRUCTIONS E.G. LIGHT awlolzm Inc.
lure rat rig to the sprinkler base part number. Button_ Brass UNS C36000 1- t,sme 4 - sum , • Freme s
Finish Suffix: Brass =A, Chrome-EnloyOp F. and White Polyester= M-fsN edition of this Te> hnfcal Data Page_ a-�� 5- 2 A-ttf eBe*FIXTURES, CEILING FANS, ETC. DR IN ACCORDANCE WITH TABLE $.2.5.4.2 AND �� ���� COLLECTION
Temperature Suffix: 155 `'F (6$ °C) - B, 175 °F (79 °G) = L� Seat Assembly: Brass UNS-C31D40 n t_ D.M.Mof a- eutxm s-mo- SECTION 8.2.5.2. SPRINKLER LOCATIONS FOR CONTINUOUS OBSTRUCTIONS CUSTOM, TRACT,
For example, sprinkler VK468 with a Brass finish and a 155 aF (BS 'C) temperature rating =Part No. 13637A6. Compression Screw: Brass UNS-C36000 r ' - N ARE IN COMPLIANCE WITH 8.2.5.4. MULTI -FAMILY
Fusible EiemerttAssembly: Beryllium Nickel, coated with black acrylic paint ANE) CDMMERDAI
Available Finishes And rem erature Ratings: ' "'at
p Levers: Stainless Steel UNS-S31600,am�y .A �` e 15- SOFFITS AND CABINETS TO 8E PROVIDED WITH SPRINKLER COVERAGE IN
Refef to Table'1 Lever Bar Copper Alloy UNS-C72500 � I 3 �„ „ � ACCORDANCE WITH 8-3.3- DESIGN, ENGINEERING AND
Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Belleville Spring Sealing Assembly Nickel Alloy; coated on bath sides with Teflon Tape FRAME mot . * INSTALLATION
Cover Adapter: Cold Rolled Steel UNS-G10060, Finish: Clear Chromate over Zinc Plating a $ ��� .� 16. SPARE SPRINKLERS SHALL NOT BE REQUIRED TO BE PROVIDED IN TRACT 32879 PLAN 1.4036
Sprinkler Wrenches: s*- ACCORDANCE WITH 5.1.1,1
A. Standard Wrench: Part No- 10396MS (available since 2000) Shipping Cap: Polyethylene _ os
B- ftench for recessed sprinklers: Part No. 13.577WIB^ (available since 2006) Dover Plate Materials: 3 � i LOT 215 8128a STORM CAT COURT
r C. Optional Protective Sprinkler Cap RemoverlEsaatchean Installer Tool"' Part No- 15915 (available since 2010.) Cover Plate Assembly. Copper UNS-C11000 and Brass UNS-C26800A �+ LICENSE N0. 684600
'A %:" ratchet is required (not available from Viking). Spring: Beryllium Nickel ' �� LA QU i NTA, CA
rl, d•',rk'raar rne•n,7 m°y
"Allows rise from the floor by attaching a length of 1' diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Solder: Eutectic °"""" Vd:1N011 t "°" ""L'ux6{
Ordering infortrmtion: (Also refer tothe current Viking price list.) caoea FLATS "Sods CROSS 705 E, HARRISON ST.
Viking Freedoms Residential Concealed Pendent Sprinkler VK467 and Cover Plate Assembly must be ordered separately: azvanwl.. j ° TON FLE""rIG' SUITE 200
Form No. F 012706 Replaces page 149m-t, dated March 18, 2011. (Revised - I CORONA, CA 92879
sprinkler materials and added reference to TIA 1028R.)FIGURE F
Form No, F 072607 Replaces page 147u-z, dated Sept- 9, 2011. (Added QM Brats FTGUREE MODEL APiRTH4.2w5.6K-FACTORSPECIFiC AHJ: RIVERSIDE COUNTY FIRE DEPARTMENT PH - 8��--272 4T
5.8 K FACroR $ L 10,Y-Len FAX - �51-�72-�535
7ABLE I- ... EMPERATURE - AND
Sprinkler Temperature Sprinkler Nominal Maximum AmNent Bulb Color
Classification Temperature Rating' Ceiting Teopetatured
Ordinary
155 :,F (68 -C)
100 tF (38 `'C) Red
Intermediate
175 "F C79'C)
150 `F (65 °C) Yellow
Sprinkler Finishes: Brass, Chrome-Enloy`-' (patents pending), and White Polyester
Footnotes
The sprinkler temperature rating is stemped an the deflector.
2 Based on NFPA-13. Other limits may apply, depending an fire 3oading, sprinkler location, and ocher requirements of the Authority Having Jurisdiction.
Refer to specific installation standards.
Approval Chart rernperature KEY
Residential Pendent Sprinkler VK468 Flnleh
FY-x� Eacu le
apprcable}
For systems designed to NFPA 13DS0 or NFPA 13R.
For systems designed to NFPA 13, refer to the design criteria on page 1494'
Sprinkler Base
NPT Thread Size
Nominal K-Factor
Maximum Water
Uverall Length
Part Numbers
SIN
Working Pressure
Inches
mm I
U.S.
F-m-eide
Inches
mm
13637
VK468
V2
15
4.9
70.6
175 psi (12 bar)
2-114
58
Listings and Approval93
Maximum Areas of Coverage'
Minimum Water Supply Requirements'
(Refer also to Design Criteria on page 1490
cULusb 1 NYC' NSFa
Installed below smooth, flat, horizontal ceilings, Including ceilings with slopes up to and Including 2112 (9.5°).
12 ft. x 12 ft- (3.7 m x 3.7 m)
13 gpm @ TO psi (49.2 Umin @ 0-48 bar)
A1X
A1X
A1X
14 ft. x 14 ft- (4-3 m x 4.3 m)
13 gpm @ 7.0 psi (49.2 Umin @ 0.48 bar)
AIX
Aix
A1X
16 ft, x 16 ft. (4.9 m x 4.9 m)
13 gpm @ TO psi (49-2 Umin @ 0.48 bar)
AIX
AIX
AIX
18 ft. x 13 ft, (5.5 m x 5.5 m)
17 gpm @ 12.0 psi (64.4 Umin @ 0-83 bar)
AIX
A1X
A1X
20 ft. x 20 ft. (6.1 m x 6.1 m)
20 gpm @ 16.7 psi (75.7 Umin @ 1.15 bar)
A1X
A1X
AIX
Installed below horizontal ceilings with beams'.
12 ff. x 12 ft. (3.7 m x 3.7 m)
13 gpm @ 7.0 psi (49.2 Umin @ 0.48 bar)
B1X
Bix
Bix
14 ft x 14 ft. (4,3 m x 4.3 m)
13 gpm @ 7.0 psi (49.2 Umin @ 0.48 bar)
Bix
Bix
Bix
16fLx16ft. (4.9mx4.9m)
13gpm@7.0psi (49.2Umin@0.48bar)
Bix
B1X
B1X
18 ft. x 18 ft. (5.5 m x 5.5 m)
17 gpm L 12.0 psi (64.4 Umin @ 0.83 bar)
Bix
61X
B1X
20 ft. x 20 ft. (6.1 m x 6.1 m}
20 gpm @ 16.7 psi (75.7 Umin @ 1.16 bar)
Bix
B1X
B1X
Installed below ceilings with slopes" up to and Including a 8112 (33.7') pitch. Refer to Figure 5 on page 149q.
UL
NYC
NSF°
20 ft. x 20 ft, (6.1 m x 6.1 m)
21 gpm @ 19.4 psi (70.5 Umin @ 1.27 bar)
BIX
see Footnote7.
131X
20 ft. x 20 ft, (6.1 m x 6.1 m)
23 gpm @ 22.0 psi (83.4 Umin @ 1.52 bar)
Cix
sea Foctnate7.
C1X
Approved Temperature Ratings
Approved Finishes
Approved Escutcheons
A - 155'F (68 °C) and 175 °F (79 'C)
Brass, Chrome-Enloy White, and
1 ®
X - Standard surface -mounted escutcheons or the Micro-
B - 155 'F (68 -C)
Blackiz
fast"' Model F-1 Adjustable Escutcheon, or recessed with
C 175 ,F (79 °C)
the Micromatic* Model E-1 or E-2 Recessed Escutcheon
Footnotes
Part number shown is the base part number. For complete part number, refer to current Viking price list schedule.
2 Metric K-factor measurement shown is when pressure is measured in Bar, When pressure is measured in kPa, divide the memc K-factor shown by
10.0.
This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any
additional approvals.
° For areas or coverage smaller than shown, use the'Minimum Water Supply Requirement" for the next larger area listed. Flows and pressures listed
are per sprinkler. The distance from slanniders to walls shall not exceed one-half the sprinkler spacing indicated for the minimum Water Supply
Requirement" used.
' Listed by Underwriter's Laboratories for use rn the U.S. and Canada.
' Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 36.
' Meets New York City requirements, effective July 1, 2008,
' Tested and Certified by NSF (National Sanitation Foundation) to NSFIANSI Standard 61, Drinking Water System Components.
9 Listings are for residential occupancies with smooth, tat, horizontal ceilings OF horizontal ceilings with teams. Indudes ceilings with slopes up to and including
a 2112(9.5°) pkii (Forbeam ceiling design alteria mtrto Beam Ceiling Guidelines and Figures 6 threugh 7D on pages 149SA).
'°Refer to TIA 1028R slope ceiling crit8ria exceptions_
"Areas under sloped ceilings must be measured along the ceiling slope- Actual floor coverage in the horizontal plane under sloped ceilings will be less
than the listed area of coverage.
'Other paint colors are available on request with the same cULus Listings as the standard finish colors.
0E91914 01TEIRIA
(Also refer to the Approve] Chart sv M4g 1434.)
f'i Lus Llstina RLijuirements:
Mohan using Viking Residential Pendent Sprinkler VK468 for systems designed to NFRA 131) or NFPA 13R. apply the listed areas of coverage and
minimum water supply requirements sho%,n in the Approval Chart on page 1490
For syskems designed to `JFPA 11 The (lumber of design sprinklers is to be the tour contiguous most hydraulically demanding sprinklers. The mini-
mum required discharge front each of the four sprinklers is to be the greater of the following
The flaw rates given in the Approval Chart on data page 1490 for NFPA 131) and NFPAI3R applications far each listed area of coverage, S1
Calculated based on a minimum discharge of 0.1 gpmisq, ft. over the "design area" in accordance with sections 8.5.2.1 or 8,6.2.1,2 of NFPA 13.
• Minimum distance between residential sprinklers: 8 R. (2A m)
4faDEi HIP wmf - APALICAT+CN C1]aX9U T7R E
t4 wrinkler materials and added reference to TIA 1023R,) SPS'CiRCAPPL(CATION ATTIC SPR+NKLFAS SPACE SPRINKLERS
AP 9p6niler (Attic Plus)
���� CS`
i#
Operation ��
P
_
The v leddlge s of shale plans hereby
acknOvl' e3 that all any, details,
+ey/tended
Installed in the upri N cnentadon with
specillcallvns or methods of Installation
[heir doFlector parallel to the roci, the
Model Ale Sprinklers p all (Figure F} are he
he
! eta I
B8 tlf�.e 14 , HIP ".al
a AP (e.Bb
h al �� f ■ 1 I
f NOTES
■■1L O1
LEGAL
� T f j j J
DESCRIPTION
contained in this set of plans is tF,e sale
property of Fire Sprinkler 5yst+�ns, Inc.
m usedta provIca protectiin-on
of attic areas olAside the scope of Orr
far the EM. SD, HIP Sprfal-
Approvals
ur & C-LIE (sled. (T� approvals ex,y
The glass {1u Ib cvnteko a at That ex -I■
lb
panes when earposed to heat When the
1 1► Y
and that any use of this set of plans is
rohibited and is a violation of copyright
plication ar
kters- When used, the AP Sprinkled
apply m t:q senAce condttlana Ind F
rotor tempera4ura is reached, the fhid
Paws first
hydraulic
rated in the gn Criteria section on
expends suf6demly to shamr,he glass
without receiving permission
-
will pnhvido a swan fta 04er B and Design cuiddlnes ego- bum, arowing the Wri nkler to sctivale
Standard Spray aprinklara for the pro- lion on Pag ] and water to now
from Fire Sprinkler Systems.
bastion of attic areas outelde the rlcopo
of nlicarlon for the BB, 9D, or HIP
span lien.
Pipe ThreaQ Conneot]an
112 inch NPT for KR4.2 & 5.6 V4 inch
tag "- .0) 4 SID 0(-6.6)
The kislblB Ilnk assefribly Is cam prload
�j j U PA N �jY
R U
'
-
NPT for K- 21p
to link h wh' joined
of o elves iCh are ed by
Drxh a ditiern
the
a thin layer of solder. When the older
temperature to reached, the solder
CONSTRUCTION:
V- B
K=4,2 GP IPSI'�90,9'PMrhar�f')
K = 5.5 GP rpsiw rSgB LPMrbar"x}
melt8 and the twPlink tlahre55gperetg,
a0ewrto the eprhlder to ac€vats arid
K=S.OGP /pal'Yr(t15,5LPMrtlarl'gj
walwmfkrw.
STORIES:
1
Raftg
ergssailer pa(K4,2aefollaa w$;
-2r
aa°Ff43 for (KL.2 Iss.o>,
HIP, AP
BUILDING AREA;
4,769 SQ.FT.
-212•F/10C ror till "'6), SD
MODEL
x
SIN
AL IAWA9LE
ROOF
rSPAN,1")MIFL
Fe4t(m)
1
m M
Gp61 ^d
mimmuM
PREMIUM
polow)'
i%"Boer Rua(W'
MY PIPE
6f8iiM
uklamt)m
WATER
4EUVERY
77k11r.
86COWS
S81
BA
7Y41eD
sW 08.g}
86 r1441
22.6 (14)
4,12 P,'d to Iles than712 (Sul
(q
eat
9A
TYn81
sa0t18,31
36 (1r
me[1A
7.1205$tolesethan1012VM
(0
B83
BA
7Y4182
s30 (16,3}
40054.
mo (1,7)
10:12 03) l❑ 19:12 t100)
00
B91
"
TYa1Bo
'40(t2,2) W SOO 119,3)
3e(1
48.0 a2)
4:1233) to lase than 7.12 pie)
04
Bat
5-6
TYne1
�40(12,2) to 00 (18,3)
38 {1
46.0(30
712 (SA to lees than 10:12 (OM
{raj
Rai
5�6
TY31ip
r40(12.0 to 6a 11e,3)
T. n
46.0 {3,2}
10.12 (8n) la 1212 (360j
(yi
sal
5-6
Tl' W
Soo 02A
25(95).
20.0 (1A
4:1Q (330 to lays than 712 P6)
{a)
eat
6A
Yyalei
s40 n2"�
2b Nkq
20A VA_
7:12 {say tp lem,hw M12 W)
{q
Bab
&0
TY3102
540 02,2)
's f05}
2010 (1A 1
10-12 (aft io 12:12 000)
N
1331
42
1Y2190
s20 M,1)
13 (4a)
9-6 W)
3:12 R5) to lean 6hen T12 (56)
45 (df
13132
42
TY2161
s20 (6,1)
13 (a9)
:
9.6 W.7)
712 (50 to lase than 10:12 M
46 M
BRS
1 42
jTV71a2
S20 (67)
13 (*
i
9 6 (0.7)
10,12 (W) le t2.12 (1 OM
45 W)
SDI
5.6
7Y3193
�30 0,1) to s40 (12,P)
35(t
as R.7)
4,12 P,'O to I®se tkan 712 (50
N
s02
5.6
TY3184
136 (a,1}to s4a t12.2)
ae 0
mn P-7)
712 P%to 1m than ID12 (63y
lck
SW
Sa
rf516e
530(9,1)w54a02,2)
3603#
mc(2.7)
10:12031to12:12(1001
{Cj
Sd1
6.6
7Y3183
a10 (3,0) to 530 M.1}
25 N51
2a0 tor$
4:12 4a) to kna than7:i2"
{cy
SM
S.5
TY31$4
.10 (S,0) A. s30 (9,) '.
26 (W°ca.0
(1,.1)
7:72 g6�to rose than 1tk12 (alp
(�
spa
5.5
TY3186
S10 [3,0} 10 s30 [0::)
25 (W
20.0 041
1"2 [66) to 1212 [100)
to
801
5.5
TY3183
51opro)
1t3(72)
115[0,6]
4:1294talawthm7:120
(6
SR2
5.6
7Y3184
510 (am
19 (72)
'
11.6 PA)
M12 �5% to 1-9 then 1M12 (0
(Cy
SW
6.6
TY31M
,10 (3A)
19[72).
115 (D.0)
70:12 (83) to 12:12 000
(b)
HIP
5.6
TYa187
-20 (9,1) W S26 (9.5)
34 (1
36.9 (2,5)
412 ISM to 12:12 0001
1 (0
W P
5.B
TY3187
r= (6,1)
25 R5)
i
I PU 0.4)
4:12 P-%to 12:12 (1001
N
AP
Yes
TY9190
10 All x 12 (a.q
Seerota•0)
Mhlmu
mumd
(4,1 �
7 pal {DAB bag Mlrtt-
gprNaq,n
Injaseipn Density
W 2 CM to 1112 (100)
60 (d)
AP
4,2
TY2190
302 (251m 12:72 [106]
60(d)
NOTES
{a) The 99 and SO rbaf span Is mcesured hn frmsaly Vat the slppa4 as shown m Figure 1 and 2-
T11e HIP roar 9 6 nlaaaul9d nor¢arnak a9 el,avm t2 .
{0) I� Y ��
{o} Fifi}af m 200 / Btllttall of :4FH4 1:j, Srlcdon 723.
(d) Ma rwm wanir delkwy Torre far all SZB m sys,oms.
(a) The AP verb span a mamurod along the slope Maxi 14 rea Rl " perpanocularto slope by maldrn'r.R 12 feet Gee my
parallel m aldpe.
FIRE SPRINKLER SYSTEM:
DESIGNED AND INSTALLED PER 2013 NFPA 13D ALL
RESIDENTIAL WITH A .B5 DENSITY WITHIN AREAS.
0
z
UU
CD
UU
J
BUILDING SUMMARY
CONCEALED RES. PENDENT SPRINKLER
0 UPRIGHT QUICK RESPONSE SPRINKLER
lU
CONCEALED RES. PENDENT SPRINKLER
0
APPROVAL]
'I�)('3iEl�IL�E COUNTYNTYFIREE I] , IS
CHANGE IN ELEVATION
J �
�FS
aG AM��A NaTTrN HA
33
RISER LOCATION PER DETAIL)
f t t--1P1 tOEPT APPROVAL FOR PLANS w
AUGFOkONE YEAR-SUBB]ECTM G NODE POINT FOR CALCULATION
COMPLIANCE Wf H APPLICABLE CODE'S z
HANGER TIC DETAIL W
i
VK457 CONCEALED PENDENT M1C-01%r4OFA T UPRIGHT APPROVAL SAL STAMP SYMBOL LEGEND
NOT TO SCALE NOT TO SCALE
�I 10' ELEV.
fY
`CPVC TO SYSTEM
Lu -�c�
I � �fYQ �
� Z
HYDRAULIC SYSTEM SPARE SPRINKLERS SHALL - _ _ `-' , - oo LU
NOT BE REQUIRED TOPRES1
This Building is Protected by a PROVIDED PER 5.1.1.1
VK45S CONCEALED PENDENT To BESSETAT QUPS[�OR *FDR REFERENCE ONLY Hydraulically Designed I 8' ELEV. I
NOT TO SCALE TO DOMESTIC WATER Automatic rinkler System. O
CONTROL VALVE FOR DOMESTIC
5 GPM ALLOWANCE ! 1" CPVC; RISER
Date Installed 3/12/14 l
Location CALLA AREA 2 GAUGE I 14-112" x 30"
T � ACCESS Doan
2r ELEV. Number of Sprinklers 1
JOB NO: 3119$
Basis of Design I DATE: 3/12114
CONTROL BALL VALVE 1. DENSITY .05 gPM1Sq.ft. I DRAWN BY: F.L.
FINISH GRADE a' ELEV. 2. DESIGNED AREA CF pISCHARGE 112" MAIN DRAIN VALVE
1 1" METER 400 Sq oft. - 4_
1 /4n COPPER L STATIC SQ 1 D 1 72 PSI
4 PSI LOSS
System Demand DRAIN TO E7�TERIC)R RESIDUAL 20 - � Oq1� =18 PSI � CLASS CATION
1. WATER FLOW RATE 2Q,� gprp G-16
1'/a' PVC MErBR I" COPPER K C1 - LICENSE :
MAIM 2. RESIDUAL PRESSURF AT THE FLOW 1580 GPM
70' MAX 30 MAX68460
-1.5' ELEV. BASE OF THE RISER 35,1 pail RUBBER FACED CHECK HALVE
WA TER FL O W INFORMA TION OF CAS
-1.5' ELEV. -1.5' ELEV.
Installed By Fire Sprinkler Systems, Inc. L -- - - -
SIZE - 30a X 42"
r
Li
WORK FOR FIRE SPRINKLER SCALE
ALL C)
SYSTEMS, INC. TO BEGIN AT B.D.R. IFSHEEIT13AREDULESS AE
24" X 36" IT 15 A REDUCED
PRINTSCALE
REDUCE ACCORDINGLY
SHEET ID
PLAN 1,4036
UNDERGROUND DETAIL HYDRAULIC NAMEPLATE RISER DETAIL GENTFP NOTES
SHEET F1 OF FP3
NOT TO SCALE NOT TO SCALE NOT TO SCALE
TABLE..
_ TEMPrERATURERATINGS
SprinKW Sprinkler Nominal Maximum
Temperature Rating Cover Plate
Large Cover I Square Cover
Temperature Tempandum Ambient Ceiling
of the Cover Base Part
Plate Base Plate Base
Classiftcatiorl IRaliW TemperatuW
Assembly (Required) filumbeP
Fart Numbera Part Number'
Ordinary 165 "F (74 °C)
100 °F (38 °C)
135 F (57 C)
13504
13642 15394
Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted
White, Painted Ivory, or Painted Black
Approval Chart sp&Wir Temperature Ratlrlg
�°oar nee Te'npeasum Ratlns
Residential Concealed Pendant Sprinkler VK457 i
For systems designed to NFPA 1301 or NFPA 13R. A_ ItCa°BrPkft FlnlsT, racy
For systems designed to NFPA 13, refer to the design criteria on page 147x.
Sprinkler Base
NPT Thread Size
Nominal K-Factor
Maximum Water
Part Number'
SIN
Working Pressure
Inches
mm
U.S.
metric'
14694A
VK457
1)2
15
4.9
70.6
175 psi (12 bar)
Listings and Approvals'
Maximum Areas of Coverage' Minimum Water Supply Requirements°
(Refer also to Design Criteria on page 147x.)
cULus` I NYC NSFI
installed below smooth, flat, horizontal ceilings, including ceilings with slopes up to and including 2112 t9.5').
12 ft. x 12 ft. (3-7 m x 3.7 m)
13 gpm @ 7.0 psi (49.2 Umin @ 0.48 bar)
AX1
See Foe(noW Sr
AXI
14 t. x 14 ft. (4.3 m x 4.3 m)
13 gpm @ TO psi (49.2 Urrlin @ 0.48 bar)
AX1
sae Foohlote s.
AXi
16 ft- x 18 ft- (4.9 m x 4.9 m)
13 gpm @ 7.0 psi (49-2 Umin @ 0.4a bar)
AX1
see Footnote 5.
AXII
18 ft. x 18 ft. (5-5 m x 5.5 m)
17 gpm Q 12,0 psi (64.4 Umin @ 0.63 bar)
AX1
Sae Footnote S.
AX1
20 ft. x 20 ft. (6.1 m x 6-1 m)
20 gpm § 16.7 psi (75.7 Umin @ 1.16 bar)
AX1
see Fout-ora 5.
AX1
Installed below ceilings with slopes' up to and including a 8112 133.7') pitch. Refer to Figure 5 on page 147x.
UL
NYC
NSF'
16 ft. x 16 ft. (4.9 m x 4.9 m)
26 gpm @ 28.2 psi (98.4 Umin @ 1.94 bar)
AX1
see Footnota5.
AX1
18 ft. x 18 ft. (5.5 m x 5.5 m)
31 gpm @ 40.0 psi (117.3 Umin @ 2.76 bar)
AM
see Footnotes.
AX1
20 ft. x 20 ft. (6.1 m x 6-1 m)
31 gpm @ 40-0 psi (117.3 Umin @ 2.76 bar)
AX1
see Footnote 5.
AX7
Cover Temperature Rating
Cover Plate Finishes
Sprinkler Temperature Rating
X - 135 •F (57 'C) cover 135041, 13642r (large diameter),
1 Polished Chrome, Brushed Chrome, Bright
Brass, Antique Brass, Brushed Brass, Brushed
A - 165 -F (74 °C)
or 15394' (square corer plate)
Capper, Painted White, Painted Ivory, or Painted
Blacki0
DESIGN CRi1"IwB
(Also fefe r to the Apprrnral Chart {Sri page 147,v.)
cULus Listing Renuirements:
When using Viking Residential Concealed Pendent Sprinkler VK457 for systems designed to NFPA 13D or NFPA 13R. apply the listed areas of cover-
age and minimum water supply requirements shown in the Approval Chart on page 147w.
Epr systems designed to NFPA f 3' The number of design sprinklers is to be the four contiguous most tlydraurically demanding sprinklers. Tl-m minim urn
required discharge from each of the fa tr sprinklers is to t}e the greater of the following:
• The flow rates given in the Approval Chart on data page 147w for NFPA 13D and NFPA 13R applications for each listed area of coverage,
,4C
• Calculated base d on a minimum discharge of 0.1 gp". ft_ over the 'deign area" to accordance with sections 8.5.2.1 or 3.6.2.1.2 of NFPA 13.
- Minimum distance between residential sprinklers- 8 ft. (2.4 m).
NOTE: Concealed sprinklers must he installed in nouttal or negative pressure plenums only.
M
0
h
DATE: 3/12/2014 S:\2014\31198\C, '\PLAN 4036.rdf I
Page 1
FIRE SPRINKLER SYSTEMS
705 E. HARRISON, SUITE 200
CORONA,CA 92879
RESIDENTIAL SPRINKLER SYSTEM
HYDRAULICS CALCULATION REPORT
FOR
PIMLICO COLLECTION "PLAN 4036"
LA QUINTA, CA
TRACT 32879
1096 TAKEN OFF,WATER SUPPLY FOR SAFETY MARGIN
CALC AREA 1
Date: 3'/12/2014
File No: 31198
Data File Name: PLAN 4036.rdf
SPRINKLER SPACING
256.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs:
16.0 ft.
Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall:
8.0 ft.
SPRINKLER SPECIFICATIONS
Mfr: Viking Descr: VK457 Conc.Pend.(16xl6) K=4.90
Calculated K Factor for Arm-Overs & Drops:
1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee)
0.0 ft. x 0.874 in. Arm -Over: K=4.67 (Incl. 1 Tee
& 1 Ell)
PIPE SPECIFICATIONS
Type: CPVC HWC: 150
WATER SUPPLY
Source: Public Test Date: By:
Static: 72.0 psi Resid: 18.0 psi F1ow:1500.0 gpm
Public Main Size: 8 in
Domestic Demand: 5.0 gpm at node number 4
SPRINKLER DEMAND
No.Spklrs. Min Spklr. Press. Node Total Avail.
Req'd
Flowing Flow (psi) No. Flow Press.
Press.
1 13.0 7.6 19 18.0 72.0
27.1
2 13.0 7.6 19 31.1 72.0
47.3
REVIEWING AUTHORITY
RIVERSIDE COUNTY FIRE DEPARTMENT
DATE: 3/12/2014 S:\2014\31198\Cr. )\PLAN 4036.rdf Page 2
RESULTS OF ANALYSIS
PIPE &
NODE DATA
*
FLOW ANALYSIS
* 1 sprinkler flowing
* 2 sprinklers flowing
FIXD
P # END LEN
FIT.
LOSS EL
SP *DISCH FLOW
PF
PT
*DISCH FLOW
PF
PT
HWC NOD DIA
EQV.LN
PUMP (FT)
(K) *(GPM) FL/FT PE
(PSI)*(GPM)
FL/FT PE
(PSI)
1 1 30.00
B
---- -1.5
SRCE ---- 18.0
3.29
27.1
---- 31.0
9.04
47.3
150 2 0.995
6.0 ----
-1.5
---- ---- 0.09
0.00
23.8
---- 0.25
0.00
38.3
2
2 70.00
3L -4.0
-1.5
-. - ---- 18.0
1.82
23.8
---- 31.1
4.99
38.3
150
3 1.360
21.0 ----
-1.5
--.----- ---- 0.02
0.00
18.0
---- 0.05
0.00
29.3
3
3 4.00
LG ----
-1.5
---- ---- 18.0
0.20
18.0
---- 31.1
0.55
29.3
150
4 1.265
3.0 ----
2.0
-5 5 0.03
1.52
16.2
5 0.08
1.52
27.2
4
4 6.00
3RS ----
2.0
-5 5 13.0
0.52
16.2
5 26.1
1.89
27.2
150
5 1.101
11.0 ----
8.0
---- ---- 0.03
2.60
13.1
---- 0.11
2.60
22.7
5
5 2.00
C ----
8.0
----- ---- 13.0
0.09
13.1
---- 26.1
0.33
22.7
150
10 1.101
1.0 ----
10.0
---- ---- 0.03
0.87
12.2
----- 0.11
0.87
21.5
6
10 5.50
L
--- 10.0
---- ---- 13.0
0.90
12.2
----- 26.1
3.25
21.5
150
11 0.874
4.0 ----
10.0
---- ---- 0.09
0.00
11.3
---- 0.34
0.00
18.3
7
11 62.50
8R ----
10.0
---- ----- 5.0
1.14
11.3
-_-- 10.2
4.26
18.3
150
12 0.874
8.0 ----
10.0
---- ----- 0.02
0.00
10.1
---- 0.06
0.00
14.0
8
12 24.50
35R -••--
10.0
---- ----- 5.0
0.52
10.1
---- 10.2
1.96
14.0
150
13 0.874
8.0 ----
10.0
---- ---- 0.02
0.00
9.6
-- - 0.06
0.00
12.1
9
13 13.50
2LB ---
10.0
---- ---- 0.0
0.00
9.6
---- 0.0
0.00
12.1
150
14 0.874
11.0 ----
10.0
--- - 0.00
0.00
9.6
----- 0.00
0.00
12.1
10
13 9.00
2R ----
10.0
-•--- ---- 5.0
0.18
9.6
---- 10.2
0.66
12.1
150
15 0.874
2.0 ----
10.0
---- ---- 0.02
0.00
9.4
---- 0.06
0.00
11.4
11
15 18.50
4R ----
10.0
---- ----- 7.5
0.77
9.4
16.0
3.12
11.4
150
16 0.874
4.0 ----
10.0
----- •---- 0.03
0.00
8.7
---- 0.14
0.00
8.3
12
16 3.50
B ----
10.0
---- ---- 0.0
0.00
8.7
-- - 13.1
0.62
8.3
150
17 0.874
3.0 -----
10.0
4.71 ---- 0.00
0.00
8.7
13.1 0.10
0.00
7.7
13
16 9.50
B ----
10.0
---- ----- 7.5
0.43
8.7
---- 2.9
0.08
8.3
150
18 0.874
3.0 ---- 10.0
---- ---- 0.03
0.00
8.2
---- 0.01
0.00
8.2
14
18 3.50
B ----
10.0
---- ---- 13.0
0.61
8.2
---- 13.0
0.61
8.2
150
19 0.874
3.0 ----
10.0
4.71 13.0 0.09
0.00
7.6
13.0 0.09
0.00
7.6
15
18 71.00
L6R ----
10.0
---- ---- -5.5
1.54
8.2
- - -10.1
4.76
8.2
150
20 0.874
10.0 ----
10.0
---- ---- -0.02
0.00
9.8
- -- -0.06
0.00
13.0
16
20 62.50
2BGR ----
10.0
---- ---- 2.5
0.34
9.8
---- 5.8
1.57
13.0
150
15 0.874
12.0 ----
10.0
---- ----- 0.00
0.00
9.4
---- 0.02
0.00
11.4
DATE: 3/12/2014 S:\2014\31198\Cc_ )\PLAN 4036.rdf
17 20 33.00 B3R ---- 10.0 ---- ---- -8.0
150 11 0.874 6.0 ---- 10.0 -- - -0.04
Page 3
1.50 9.8 ---- -15.8 5.31 13.0
0.00 11.3 -- -0.14 0.00 18.3
Legend:
P - Pipe #
DIA - Pipe Diameter
EQV. LN - Pipe Equivalent Length
PUMP - Pump Pressure
SP - K-Factor
FLOW - Flow Rate
PF - Pressure Loss due to Friction
PT - Total Pressure at Node
Fitting Code Letters:
Node Notes
Pipe Notes
LEN - Pipe Length
FIT. - Pipe Fittings
FIXD LOSS - Fixed Loss Device
EL - Node Elevation
DISCH - Discharge in gpm
FL/FT - Friction Loss per Foot
PE - Pressure Loss due to Elevation
E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X,
The maximum velocity of water flow occurs in pipe 1
at 7.42 ft/s with 1 sprinkler flowing.
The maximum velocity of water flow occurs in pipe 6
at 13.93 ft/s with 2 sprinklers flowing.
PIPE FITTINGS TABLE
Pipe Table Name: standard.npt
PAGE: C
MATERIAL: CPVC HWC: 150
Diameter
Equivalent Fitting
Lengths
in Feet
(in)
E
L B R
C
S
G
X
Y
Z
45 Ell
90 Ell TeeBch TeeRun
Couplg
SwgChk
GatVly
X
Y
Z
0.874
1.00
4.00 3.00 1.00
1.00
5.00
2.00
0.00
0.00
0.00
1.101
1.00
5.00 5.00 1.00
1.00
8.00
2.00
0.00
0.00
0.00
PAGE: K
MATERIAL: Copper Tube-K
HWC: 150
Diameter
Equivalent Fitting
Lengths
in Feet
(in)
E
L B R
C
S
G
X
Y
Z
45 Ell
90 Ell TeeBch TeeRun
Couplg
SwgChk
GatVly
X
Y
Z
0.995
1.00
2.00 6.00 2.00
2.00
6.00
0.00
0.00
0.00
0.00
PAGE: L
MATERIAL: Copper Tube-L
HWC: 150
Diameter
Equivalent Fitting Lengths
in Feet
(in)
E
L B R
C
S
G
X
Y
Z
45 Ell
90 Ell TeeBch TeeRun
Couplg
SwgChk
GatVly
X
Y
Z
1.265
1.00
3.00 6.00 2.00
2.00
7.00
0.00
0.00
0.00
0.00
Page 4
DATE: 3/12/2014 S:\2014\31198\Cr 1\PLAN 4036.rdf
PAGE: P MATERIAL: PVC HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E L B R C S G X Y Z
45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z
1.360 2.00 7.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00
Sprinkler system has been hydraulically calculated with the
HASS HOUSE 3.2 computer program (License No. 50081444 )
to provide an average imbalance of 0.010 gpm at each node and
a maximum imbalance of 0.08 gpm with one sprinkler
flowing, and 0.010 gpm at each node and maximum imbalance
of 0.08 gpm with 2 sprinklers flowing in accordance
with NFPA 13 and 13D or 13R.
HRS Systems, Inc.
208 Southside Square
Petersburg, TN 37144
(931) 659-9760
DATE: 3/12/2014 S:\2014\31198\C.. 1\PLAN 4036.rdf
Page 5
WATER SUPPLY CURVE
75.0
A C
67.5
P
60.0
R
E
52.5
S
S
45.0
U
R
37.5
E
I_
30.0
( ! C
B
P
22.5
S
I
15.0
7.5
0.0
04 8 12 16 20 24 28 32 36 40
FLOW (GPM)
Static = 72.0 psi, Residual = 18.0 psi @ 1500 gpm
(1 sprinkler flowing) (2 sprinklers flowing)
A = Available Water Supply C = Available Water Supply
72.0 psi Q 18.0 gpm 72.0 psi @ 31.1 gpm
B = Required Water Supply D = Required Water Supply
27.1 psi @ 18.0 gpm 47.3 psi @ 31.1 gpm
DATE: 3/12/2014 S:\2014\31198\C: t\PLAN 4036.rdf Page 6
DATE: 3/12/2014 S:\2014\31198\C,__.�\PLAN 4036.rdf
Page 1
FIRE SPRINKLER SYSTEMS
705 E. HARRISON, SUITE 200
CORONA,CA 92879
RESIDENTIAL SPRINKLER SYSTEM
HYDRAULICS CALCULATION REPORT
FOR
PIMLICO COLLECTION "PLAN 4036"
LA QUINTA, CA
TRACT 32879
10% TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN
CALC AREA 2
Date: 3/12/2014
File No: 31198
Data File Name: PLAN 4036.rdf
SPRINKLER SPACING
400.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 20.0 ft.
Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 10.0 ft.
SPRINKLER SPECIFICATIONS
Mfr: Viking Descr: VK457 Conc.Pend.(20x20) K=4.90
Calculated K Factor for Arm-Overs & Drops:
1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee)
0.0 ft. x 0.874 in. Arm -Over: K=4.67 (Incl. 1 Tee & 1 Ell)
PIPE SPECIFICATIONS
Type: CPVC HWC: 150
WATER SUPPLY
Source: Public Test Date: By:
Static: 72.0 psi Resid: 18.0 psi Flow:1500.0 gpm
Public Main Size: 8 in
Domestic Demand: 5.0 gpm at node number 4
SPRINKLER DEMAND
No.Spklrs. Min Spklr. Press.
Flowing Flow (psi)
1 20.0 18.0
1 20.0 18.0
REVIEWING AUTHORITY
RIVERSIDE COUNTY FIRE DEPARTMENT
Node Total Avail. Req'd
No. Flow Press. Press.
14 25.0 72.0 50.3
14 25.0 72.0 50.3
DATE:
3/12/2014 S:\2014\31198\Ct.__-'\PLAN 4036.rdf
Page
2
RESULTS OF ANALYSIS
PIPE
&
NODE DATA
*
FLOW
ANALYSIS
* 1 sprinkler flowing
* 1 sprinklers
flowing
FIXD
p ##
END
LEN
FIT.
LOSS
EL
SP *DISCH FLOW
PF
PT *DISCH
FLOW
PF
PT
HWC
NOD
DIA
EQV.LN
PUMP
(FT)
(K) *(GPM) FL/FT
PE
(PSI)*(GPM)
FL/FT
PE
(PSI)
1
1
30.00
B ----
-1.5
SRCE ---- 25.0
6.05
50.3 ----
25.0
6.06
50.3
150
2
0.995
6.0 ----
-1.5
---- ---- 0.17
0.00
44.3 ----
0.17
0.00
44.3
2
2
70.00
3L -4.0
-1.5
---- ---- 25.0
3.34
44.3 ----
25.0
3.34
44.3
150
3
1.360
21.0 ----
-1.5
---- ----- 0.04
0.00
36.9 ----
0.04
0.00
36.9
3
3
4.00
LG ----
-1.5
---- ---- 25.0
0.37
36.9 ----
25.0
0.37
36.9
7.50
4
1.265
3.0 ----
2.0
-5 5 0.05
1.52
35.1 5
0.05
1.52
35.1
4
4
6.00
3RS ----
2.0
-5 5 20.0
1.16
35.1 5
20.0
1.16
35.1
150
5
1.101
11.0 ----
8.0
---- ---- 0.07
2.60
31.3 ----
0.07
2.60
31.3
5
5
2.00
C ----
8.0
---- ---- 20.0
0.20
31.3 ----
20.0
0.20
31.3
150
10
1.101
1.0 ----
10.0
---- - -- 0.07
0.87
30.2 ---
0.07
0.87
30.2
6
10
5.50
L ----
10.0
---- ---- 20.0
1,99
30.2 ----
20.0
1.99
30.2
150
11
0.874
4.0 ----
10.0
---- ---- 0.21
0.00
28.2 - --
0.21
0.00
28.2
7
11
62.50
8R ----
10.0
---- ---- 9.2
3.48
28.2 ----
9.2
3.48
28.2
150
12
0.874
8.0 ----
10.0
---- ---- 0.05
0.00
24.8 ----
0.05
0.00
24.8
8
12
24.50
B5R ----
10.0
---- ---- 9.2
1.61
24.8 ---
9.2
1.60
24.8
150
13
0.874
8.0 ----
10.0
---- ---- 0.05
0.00
23.2 ----
0.05
0.00
23.2
9 13 13.50
150 14 0.874
10 13 9.00
150 15 0.874
11 15 18.50
150 16 0.874
12 16 3.50
150 17 0.874
13 16 9.50
150 18 0.874
14 18 3.50
150 19 0.874
15 18 71.00
150 20 0.874
2LB ---- 10.0 ---- ---- 20.0 5.13 23.2 ---- 20.0 5.13 23.2
11.0 ---- 10.0 4.71 20.0 0.21 0.00 18.0 20.0 0.21 0.00 18.0
2R ---- 10.0 ----- ---- -10.8 0.74 23.2 ---- -10.8 0.74 23.2
2.0 ------ 10.0 ---- ---- -0.07 0.00 23.9 ---- -0.07 0.00 23.9
4R ---- 10.0 ---- ---- -4.8 0.33 23.9 ---- -4.8 0.33 23.9
4.0 ---- 10.0 ---- ---- -0.01 0.00 24.2 ---- -0.01 0.00 24.2
B ---- 10.0 ---- ---- 0.0 0.00 24.2 ----- 0.0 0.00 24.2
3.0 ---- 10.0 ---- ---- 0.00 0.00 24.2 ---- 0.00 0.00 24.2
B ---- 10.0 -- -4.8 0.18 24.2 ---- -4.8 0.18 24.2
3.0 ---- 10.0 ---- ---- -0.01 0.00 24.4 ---- -0.01 0.00 24.4
B ---- 10.0 ---- ----- 0.0 0.00 24.4 ----- 0.0 0.00 24.4
3.0 ---- 10.0 ---- ---- 0.00 0.00 24.4 ---- 0.00 0.00 24.4
L6R ---- 10.0 ---- ---- -4.8 1.20 24.4 -- -4.8 1.20 24.4
10.0 ---- 10.0 ---- ---- -0.01 0.00 25.6 ---- -0.01 0.00 25.6
16 20 62.50 2B6R ---- 10.0 ---- ---- 6.1 1.72 25.6 -- 6.1 1.72 25.6
150 15 0.874 12.0 ---- 10.0 --- 0.02 0.00 23.9 --- 0.02 0.00 23.9
DATE: 3/12/2014 S:\2014\31198\Cr_._.�\PLAN 4036.rdf
17 20 33.00 B3R ---- 10.0 ---- ---- -10.8
150 11 0.874 6.0 ---- 10.0 ---. ---- -0.07
Page 3
2.63 25.6 ---- -10.8 2.63 25.6
0.00 28.2 -- - -0.07 0.00 28.2
Legend:
P - Pipe #
DIA - Pipe Diameter
EQV. LN - Pipe Equivalent Length
PUMP - Pump Pressure
SP - K-Factor
FLOW - Flow Rate
PF - Pressure Loss due to Friction
PT - Total Pressure at Node
Fitting Code Letters:
Node Notes
Pipe Notes
LEN - Pipe Length
FIT. - Pipe Fittings
FIXD LOSS - Fixed Loss Device
EL - Node Elevation
DISCH - Discharge in gpm
FL/FT - Friction Loss per Foot
PE - Pressure Loss due to Elevation
E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X, t'
The maximum velocity of water flow occurs in pipe 9
at 10.70 ft/s with 1 sprinkler flowing.
The maximum velocity of water flow occurs in pipe 6
at 10.69 ft/s with 1 sprinklers flowing.
PIPE FITTINGS TABLE
Pipe Table Name: standard.npt
PAGE: C
MATERIAL: CPVC HWC: 150
Diameter
Equivalent Fitting
Lengths
in Feet
(in)
E
L B R
C
S
G
X
Y
Z
45 Ell
90 Ell TeeBch TeeRun
Couplg
SwgChk
GatVly
X
Y
Z
0.874
1.00
4.00 3.00 1.00
1.00
5.00
2.00
0.00
0.00
0.00
1.101
1.00
5.00 5.00 1.00
1.00
8.00
2.00
0.00
0.00
0.00
PAGE: K
MATERIAL: Copper Tube-K
HWC: 150
Diameter
Equivalent Fitting
Lengths
in Feet
(in)
E
L B R
C
S
G
X
Y
Z
45 Ell
90 Ell TeeBch TeeRun
Couplg
SwgChk
GatVly
X
Y
Z
0.995
1.00
2.00 6.00 2.00
2.00
6.00
0.00
0.00
0.00
0.00
PAGE: L
MATERIAL: Copper Tube-L
HWC: 150
Diameter
Equivalent Fitting
Lengths
in Feet
(in)
E
L B R
C
S
G
X
Y
Z
45 Ell
90 Ell TeeBch TeeRun
Couplg
SwgChk
GatVly
X
Y
Z
1.265
1.00
3.00 6.00 2.00
2.00
7.00
0.00
0.00
0.00
0.00
DATE: 3/12/2014 S:\2014\31198\Ct _'\PLAN 4036.rdf Page 4
. ,
PAGE: P 0\ MATERIAL: PVC HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E L B R C S G X Y Z
45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z
1.360 2.00 7.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00
Sprinkler system has been hydraulically calculated with the
HASS HOUSE 3.2 computer program (License No. 50081444 )
to provide an average imbalance of 0.010 gpm at each node and
a maximum imbalance of 0.09 gpm with one sprinkler
flowing, and 0.010 gpm at each node and maximum imbalance
of 0.01 gpm with 1 sprinklers flowing in accordance
with NFPA 13 and 13D or 13R.
HRS Systems, Inc.
208 Southside Square
Petersburg, TN 37144
(931) 659-9760
DATE: 3/12/2014 S:\2014\31198\d_ A\PLAN 4036.rdf
M �
� I Page 5
75.0
67.5
P
1.
60.0
R -
E
52.5
S
S
45.0
U
R
37.5
E
( 30.0
P
22.5
S
I
15.0
I
7.5
0.0
04 8 12 16
WATER SUPPLY CURVE
20 24 28 32
FLOW (GPM)
36 40
Static = 72.0 psi, Residual = 18.0 psi @ 1500 gpm
(1 sprinkler flowing) (1 sprinklers flowing)
A = Available Water Supply C = Available Water Supply
72.0 psi @ 25.0 gpm 72.0 psi @ 25.0 gpm
3 = Required Water Supply D = Required Water Supply
50.3 psi @ 25.0 gpm 50.3 psi @ 25.0 gpm
Z
Residential Connection Charge Estimate
Date:
April 21, 2014
Customer Name:
Lennar Homes, Inc.
Phone No.
(951) 817-3526
Parcel No.
767-790-054
Geo.
06-07-15-2
Address:
81280 Storm Cat Crt, La Quinta
LID:
669364 Block No.
Lot No.
215 size of Lot:
18,731
sq. ft. Tract No. 32879
Type of Service:
R-1: 0 Duplex: ❑
Triplex:
❑ Apts: ❑
SWSC:
$
- Acres:
0
SWSC: $12,218.00 /acre
WSBFC:
$
3,707.00
SCC:
$
4,851.00
Treatment:
$2,395/edu Collection: $1,836/edu
Meter:
$
400.00 Meter Size:
1
inch
Meter surcharge:
$
2,479.00 servicesize:
1
inch
Service:
$
-
Meter & Service:
$
_
Backflow:
$
_
Other::
$
_
(see explanation
below)
Sewer Lateral:
$
_
Total:
$
11,437.00
Other:
Abandon / Rekxate
Information Supplied By Customer
Domestic Water Demand*
Max. Flow= 15-20 gpm
Min. Pressure=
Fire Sylinkler Derr nd *
Max. Flow=
Min. Pressure=
system Type:
60 psi
31.5 gpm
49 psi
Multi F±1 Stand Alone ❑
CVWD System Data
Service Connection"
Max. Flow*= 31.5 gpm
Inlet Pressure = 77 psi
Outlet Pressure= 51 psi
Meter Size = 1 inch
Service Size= 1 inch
** For Calculation Purposes- Service Conne , ion Includes:
• CVWD USES WORST CASE CONDITION Service Connection Pipe=50', Meter Stop, Meter, Check Valve & Shut Off Valve
Notes: Tract No. 32879, Griffin Ranch, Phase 113-213 conists of 9.44 acres. The SIWSC will be charged on the first meter
requested in this phase, which is Lid 669372, P2 14-5311. Per Construction Dwg, No. 35207 there is an existing
1" service and per Dwg. No. 35215 there is a sewer lateral. E-mail Invoice to: larry.liebel@lennar.com &
Ulrich ---- PZ 14-5414
Technician: Sandra Villalobos Approved by: Date: -y—e a, /`l
cvwd-950
*********This is iiist a ni InTF all fPPC arP Ciihipr't to rhansrP********* 3 3 1-)/1-1
PROUDLY SERVING THE
UNINCORPORATED AREAS
OF RIVERSIDE COUNTY
AND THE CITIES OF:
BANNING
BEAUMONT
CALIMESA
CANYON LAKE
C OAC H E LLA
DESERT HOT SPRINGS
EASTVALE
INDIAN WELLS
INDIO
JURUPA VALLEY
LAKE ELSINORE
LA QUINTA
MENIFEE
MORENO VALLEY
NORCO
PALM DESERT
PERRIS
RANCHO MIRAGE
RUBIDOUx CSD
SAN JACINTO
TEMECULA
WILDOMAR
BOARD OF
SUPERVISORS:
KEVIN JEFFRIES
DISTRICT 1
JOHN TAVAGLIONE
DISTRICT 2
JEFF STONE
DISTRICT 3
JOHN BENOIT
DISTRICT 4
MARION ASHLEY
DISTRICT 5
RIVERSIDE COUNTY FIRE, )EPARTMENT
IN COOPERATION WITH
THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION
77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 92211-4131 ■ Phone (760) 863-8886
• Fax (760) 863-7072
www.rvcfire.org
April 30',2014
Fire Sprinkler Systems
705 E. Harrison Street,Ste.# 200
Corona, CA 92879
Re: Residential Fire Sprinkler Plan Review
LAQ-I4-RS-033, Pimlico Lot 215, 81-280 Storm Cat Ct. La Quinta, CA
The sprinkler plans you submitted for the above referenced project have been reviewed by
Riverside County Fire Department Planning & Engineering personnel and are approved
with the following conditions.
A minimum of three spare fire sprinklers of each type and temperature rating along with a
sprinkler wrench should be located in a spare cabinet at the system riser or other approved
location.
Permanently marked identification signs shall be attached to all control valves.
A warning sign, with minimum 1/ inch letters, shall be affixed adjacent to the main shutoff
valve and shall state the following:
WARNING: The water system for this home supplies fire sprinklers that require certain flows and
pressures to fight a fire sprinkler system, such as water softeners, filtration systems, and automatic
shut-off valves, shall not be added to the system without a review of the fire sprinkler system by a
fire protections specialist. DO NOT remove this sign.
The following inspections/tests are required to be witnessed by the Fire Department Planning
Division Staff:
(a) Overhead Rough and Hydro static test: All piping shall be visible and
pumped at normal operating pressure
(b) Final inspection
The Fire Department job card, approved plans and condition letter must be at the job site or
NO inspection will be performed. Applicant/installer shall be responsible to contact the Fire
Department to schedule inspection(s) a minimum of 72 hours prior to the requested
inspection date.
All questions regarding the meaning of these conditions should be referred to the Fire
Department Planning & Engineering Staff at (760) 863 8886.
Sincerely,
Lisa Nottingham, Fire Safety Specialist
PROUDLY SERVING THE
UNINCORPORATED AREA£
OF RIVERSIDE COUNTY
AND THE CITIES OF:
BANNING
BEAUMONT
CALIMESA
CANYON LAKE
COACHELLA
DESERT HOT SPRINGS
EASTVALE
INDIAN WELLS
INDIO
JURUPA VALLEY
LAKE ELSINORE
LA QUINTA
MENIFEE
MORENO VALLEY
NORCO
PALM DESERT
PERRIS
RANCHO MIRAGE
RuBIDOUx CSD
SAN JACINTO
TEMECULA
WILDOMAR
BOARD OF
SUPERVISORS:
KEVIN JEFFRIES
DISTRICT 1
JOHN TAVAGLIONE
DISTRICT 2
JEFF STONE
DISTRICT 3
JOHN BENOIT
DISTRICT 4
MARION ASHLEY
DISTRICT 5
RIVERSIDE COUNTY FIF DEPARTMENT
IN COOPERATION 4ITH
THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION
77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 92211-4131 • Phone (760) 863-8886
• Fax (760) 863-7072
www.rvcfire.org
March 28, 2014
Fire Sprinkler Systems
705 E. Harrison St. #200
Corona, CA
Re: Residential Fire Sprinkler Review
LAQ-I4-RS-033 Belmont 81-280 Storm Cat Court Lot 215 La Quinta, CA
The Riverside County Fire Department Planning & Engineering personnel have reviewed
your sprinkler plans for the above referenced project. Please be advised that your plans
require the following corrections:
Please provide the following information in your next submittal:
1) Provide a recent (within 6 months) Residential Connection Charge Estimate form
from CWVD.
NO inspections will be performed until Riverside County Fire Department Planning
& Engineering staff has approved the corrected plans.
All questions regarding the meaning of these conditions should be referred to the Riverside
County Fire Department Planning & Engineering staff at (760) 863-8886.
Sincerely,
Jason Stubble
Fire Safety Specialist
Otero, Stephen@CALFIRE
Subject: LAQ-I4-RS-036 - GRIFFIN RANCH/PIMLICO LOT 213 - RES SPK FINAL
Location: 81340 STORM CAT COURT LOT 213, LA QUINTA
Start: Tue 7/22/2014 1:00 PM
End: Tue 7/22/2014 1:30 PM
Recurrence: (none)
Organizer: Hetrick, Kohl@CALFIRE
Rep. Name:
Phone#:
HYDRANT SYSTEM
Thrust block re- our
Underground rough
Flush
Final
SPRINKLER U.G.
Thrust block are -pour
under round rough
Underground hydro
Flush
Final
FIRE SPRINKLER
Weld ins ection
Overhead rough piping
Overhead hydro
UG flush / OK to connect
Main drain/inspect, Test
Hi h pile stora e
In-racksprinklers
Hose racks
X Final
KITCHEN HOOD EXTINGUISHING
Detections stem
Function Test
Gas/Electrical shut-off
Nozzle model/placement
Fire alarm connection
Final
SPRAY BOOTHS
Installation
Air flow test
Mechanical interlock
Extinguishing system
Fire alarm connection
Final
Start Time: [ ; 'j ei Finish Time:
Start Time: Finish Time:
Cell#:
PASS
FAIL
Co. Name:
CrossSt:
FIRE ALARM
Rough -wire inspection
Function test
Duct detectors/veIocity
24 hr. battery test
Sprinkler monitoring
Final
SPECIAL SUPPRESSION
Door fan test
Abort test
Mechanical shutdown
Detector test
Deluge/pre-action
Final
UST/AST TANK
Installation
Removal
shut off
Dispensers & shear valves _
Final
M ISC. INSPECTION
Spray booths
Hood/duct extinguishing
High pile rack storage
H.P. vents/access/corridors
Tract access/hydrant verification
Other:
KNOX SYSTEM
Building Knox box
Gate access Knox box/padlock
BUILDING INSPECTIONS
T/I final
Shell final
Final for occuuancv
PASS I FAIL
I
Stubble, Jason@CALFIRE
Subject: LAQ-I4-RS-033 - PIMLICO - LOT#215 - O.H. ROUGH
Location: 81280 STORM CAT COURT, LOT#215, LA QUINTA
Start: Fri 5/2/2014 8:40 AM
End: Fri 5/2/2014 9:00 AM
Recurrence: (none)
Organizer: Stubble, Jason@CALFIRE
Rep. Name: Jr
Phone#: 951-733-0485 Cell#:
HYDRANT SYSTEM PASS
Thrust block pre -pour
Underground rough
Flush
Final
SPRINKLER U.G.
Thrust block Dre-Dour
Flush
Final
FIRE SPRINKLE
Weld inspection
Overhead rough piping
Overhead hydro
UG flush / OK to connect
Main drain/Inspect. Test
In-racksprinklers
Hose racks
Final
KITCHEN HOOD EXTINGUISHING
Detections stem
I
nction Test
s/Electrical shut-off
zzle model/placement
e alarm connection
al
SPRAY BOOTHS
Installation
Air flow test
Mechanical interlock
Extin uishin system
Fire alarm connection
Final d `•
Start Time: Finish Time:
Start Time: Finish Time:
FAIL
Co. Name:
FSS
CrossSt:
FIRE ALARM
Function test
Duct detectorsivelocity
24 hr. battery test _
Sprinkler monitoring _
Final
SPECIAL SUPPRESSION
Door fan test
Abort test
Mechanical shutdown
Detector test
Deluge/pre-action
Final
UST/AST TANK
Installation
Removal
Emergency shut off
Dispensers & shear valves
Final
MISC. INSPECTION
Spray booths
Hood/duct extinguishing
High pile rack storage
H.P. vents/access/corridors
Tract access/hydrant verification
Other:
KNOX SYSTEM
Building Knox box
Gate access Knox box/padlock
BUILDING INSPECTIONS
T/I final
Shell final
Final for occupancv
FAIL
1
Riverside County Fire apartment 5 Fire Prot( --Lion Planning Section
Riverside D(Goe: 2300 WrKot S! L Ste. 150. Riverside, CA 92601 Ph. (951).955-4777 Fax (951) 955.4896
Murriela QFRce: 39493 Las Alamos Rd., Ste A, Murrleta. CA 92563 Ph. (B51 ) W-6160 Fax (951 ) 600-61e4
Palm Desert Office: 77-933 Las Marilanas Rd., � 201 palm Desert, CA 92211.4131 Ph. (160) 863-0896 (760) 863-7072
Fire Department Clearance/Release
Date: 1- a a - N 4
To: LQ
Fax:
Tract/Parcel Map #: G- 'i �AuC P, Fi L<n t o2 t 3
Permit/Lot #: UNa - \,A-
Job Site Address: S6� 34y 6\'_3Vw c� \ &,Dy f k
LX 6 ., J } A ck aas 3
Final For Recordation
Release For Building Permit(s)
Shell Final Only (No Tenant)
Final For OccupancyL_
Building Plan Check Fees Paid
Building Plan Check Fees Not Paid
Other Fees
Fees Not Required
If you should have any questions, please contact the appropriate Riverside f C�Ounty Fire Protection
Planning office for further assistance. II it
Authorizing 5l'qiiatu?e-for Release
Print Name
Form C — Revised 1/15/2014
Riverside County Fire Department
Riverside Office:
2300 Market Street, Ste. 150
Riverside, CA 92501
Phone: (951) 955-4777 -- Fax: (951) 955-4886
PLAN REVIEW FORD
D New p Re -Submittal # 1 ❑ As-builts
Peep LAQ-14-RS- fj33
Fire Protection Planning
Palm Desert Office:
77-933 Las Montarhas Rd., Ste 201
Palm Desert CA 92211
Phone: (760) 863-8886 - Fax: (760) 863..7072
Office use Only
RECEIVED
APR 2 8. 20N
iT r i , c:.,-._• a.z� , �... �:F ,Yr : 3 F�„R —n �r PRarwnWERUDEONPLdWNp
PrajecXfc'iiuir; r' �1eosPnj`, tia
:T-�::�w,
Project Name: PIMLICO l `TV&- k ��+ � � I �
I have read and understand that Fire Dept. fees are
LOT a1C g� �� c�,,,i Deposit Based Fees and there may be additional
Address:
money due ri r to or after project final.
LA QUINTA � -�� -! Sign:
City &Zip: Print: Y DESCOTEAUX ✓J•V•
CONTACT PERSON: AMY DESCOTEAUX
BILL TO: FIRE SPRINKLER SYSTEMS, INC.
Mailing Address: 705 E. HARRISON ST., SUITE 200 Mailing Address:
City & Zip CORONA, CA 92879 City & Zip
Phone No.: 800-915-3473
Fax: 951-272-2535
Email: AMYD@FIREINC.NET
Phone No.:
Email:
Fax:
The person listed on "Billing Information" will receive ALL billing, correspondence and refunds for any work billed to
this permit. Any changes in billing information must be made In writing to our office.
iClr1 Reil�� ;r1f�l • r�..,1rf2�ciiik� 3�� :� ��.'.'`f+�ea?�'`r'+�� �iY'".�:rr�xry',�_'�'�iEk��"�'. �Q _ ;r��5�r:x-nzu+s•:�nr ,.ri�ru�.,ars.�.,..._.,,_�
O Commercial O Industrial rp
O Special Event ❑ Other
D Building ❑ Building Tenant Improvement O High Fire Area ❑ Underground Water
El -.�prinkjer System ❑ TI Sprinkler System O Sprinkler Monitoring O Fire Alarm System
❑ Hood & Duct Suppression System 0 Other Suppression System O Spray Booth -O Cell Site
❑ High Pile/Racks ❑ Other:
Stogie Tank Submittals; D Dispensers Only ❑ Above Ground ❑ Underground
Fee Paid: 0
Date Paid: _
Check#:
Received By:
Receipt#(OCR)
Reviewed by: ,-
Called for Pick -Up Clw-atlezf
,�-A44t,
PC Review Date: Date: �, By:14-
❑ Approved ❑Denied Picked -Up
Plans Stamped: DYes []No
Letter Attached: DYes ❑No
Job Card Included: ❑Yes ONo
Date:. - ! r 4 By:
Shipped By / Method
Form 1—Rcviwd 1 0127C1414
Visit us at www.rvcfire.ora
Riverside County Fire Dep rment
Riverside Office:
2300 Market Street, Ste. 150
Riverside, CA 92501
Phone: (951) 955-4777 - Fax: (951) 955-4886
PLAN REVIEW FOR1Ll1
ID New ❑ Re -Submittal # ❑ As-builts
Permit No.
Project Information (Please Print)
Project Name: PIMLICO / TRACT 32879 / PLAN 1 MODEL
Address: LOT 215 / 81-280 STORM CAT COURT
City & Zip:
LA QUINTA
. ire Protection Planning
Palm Desert Office:
77-933 Las Montanas Rd., Ste 201
Palm Desert CA 92211
Phone: (760) 863-8886 - Fax: (760) 863-7072
— office ust-only
`>.
Plans'Received _'
I have read and understand that Fire Dept. fees are
Deposit Based Fees and there may be additional
money due prior to or after project final.
Sign:
Print: DESCOTEAUX
Contact Information Billing Information r_ ame as Contact Info
CONTACT PERSON: AMY DESCOTEAUX BILL TO: FIRE SPRINKLER SYSTEMS, INC.
Mailing Address: 705 E. HARRISON ST., SUITE 200 Mailing Address:
City & Zip CORONA, CA 92879
Phone No.: 800-915-3473
City & Zip
Fax:951-272-2535 Phone No.:
Email: AMYD@FIREINC.NET
Email:
Fax:
The person listed on "Billing Information" will receive ALL. Billing, correspondence and refunds for any work billed to
this permit. Any changes in billing information must be made in writing to our office.
Plan Review Type (Check appropriate items)
❑ Commercial ❑ Industrial El Residential ❑ Special Event ❑ Other
❑ Building ❑ Building Tenant Improvement ❑ High Fire Area ❑ Underground Water
IZI Sprinkler System ❑ TI Sprinkler System O Sprinkler Monitoring Q Fire Alarm System
❑ Hood & Duct Suppression System ❑ Other Suppression System ❑ Spray Booth O Cell Site
❑ High Pile/Racks ❑ Other:
Storage Tank Submittals: ❑ Dispensers Only ❑ Above Ground ❑ Underground
Fee P id:
Daaaidl:
Check#:
Received By:
Receipt#(OCR)
Form 1 —Revised ID/2712010
Reviewed by: 3as
PC Review Date:
❑ Approved S Denied
Plans Stamped: ❑Yes ®No
Letter Attached: ®Yes ❑No
Job Card Included: ❑Yes -ENo
Visit us at www.rvcfire.orq
Called for Pick -Up /4of Sa i U pfQ,,
Date: By:���
Picked -Up
Date: By:
Shipped By / Method