Loading...
LAQ-15-RS-144 Monterra Plan 2ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT WOODBRIDGE PACIFIC GROUP LLC 27285 LAS RAMBLAS SUITE #230 MISSION VIEJO CA 92691 CONTRACTOR WOODBRIDGE PACIFIC GROUP LLC 27285 LAS RAMBLAS SUITE #230 MISSION VIEJO CA 92691 OWNER MONTERRA PROP 55075 MONROE ST LA QUINTA CA 0 CONDITIONS Description: MONTERRA TM32742 LOT35 PH MODELS PLAN 2AR Type: BUILDING RESIDENTIAL Subtype: DWELLING - SINGLE FAMILY DETACHED Status: FINALED Applied: 3/18/2015 SKH Parcel No: 767860035 Site Address: 55119 AUTUMN VALLEY CT 92253,CA 92253 Approved: 8/7/2015 SKH Subdivision: TR 32742 Block: Lot: 35 Issued: 8/7/2015 SKH Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 3/6/2019 JFU Valuation: $211,182.80 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 3,220SF DWELLING - PLAN 2AR, LOT 35 [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2013 CALIFORNIA BUILDING CODES. Fire Permit #LAQ-15-RS-144. FINANCIAL INFORMATION Printed: Wednesday, February 28, 2024 3:39:40 PM 1 of 7 Permit Details City of La Quinta PERMIT NUMBER BRES2015-0092 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY ART IN PUBLIC PLACES - RESIDENTIAL 270-0000-43201 0 $27.95 $27.95 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH Total Paid for ART IN PUBLIC PLACES - AIPP: $27.95 $27.95 BSAS SB1473 FEE 101-0000-20306 0 $9.00 $9.00 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $9.00 $9.00 DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $942.00 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 $129.00 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $433.00 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH DIF - LIBRARIES 253-0000-43200 0 $344.00 $344.00 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 $40.00 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $2,048.00 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 $116.00 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 $2,842.00 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 $6,894.00 TEMP POWER SERVICE 101-0000-42403 0 $24.17 $24.17 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH TEMP POWER SERVICE PC 101-0000-42403 0 $16.92 $16.92 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH Total Paid for ELECTRICAL: $41.09 $41.09 RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $36.99 $36.99 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $15.24 $15.24 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH Printed: Wednesday, February 28, 2024 3:39:40 PM 2 of 7 Permit Details City of La Quinta PERMIT NUMBER BRES2015-0092 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $145.03 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 $47.86 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH Total Paid for ELECTRICAL - NEW CONSTRUCTION: $245.12 $245.12 RESIDENTIAL PRECISE GRADING - TRACT HOME 101-0000-42408 0 $133.43 $133.43 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH Total Paid for GRADING: $133.43 $133.43 CONDENSER/COMPRES SOR 101-0000-42402 0 $72.52 $72.52 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH CONDENSER/COMPRES SOR PC 101-0000-42600 0 $48.34 $48.34 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH EXHAUST HOOD 101-0000-42402 0 $12.09 $12.09 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH EXHAUST HOOD PC 101-0000-42600 0 $4.83 $4.83 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH FURNACE 101-0000-42402 0 $72.52 $72.52 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH FURNACE PC 101-0000-42600 0 $48.34 $48.34 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH VENT FAN 101-0000-42402 0 $84.63 $84.63 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH VENT FAN PC 101-0000-42600 0 $33.81 $33.81 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH Total Paid for MECHANICAL: $377.08 $377.08 MULTI-SPECIES RESIDENTIAL 0-8 UNITS - 2015 UPDATE 101-0000-20310 0 $1,301.00 $1,301.00 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH Total Paid for MULTI-SPECIES RESIDENTIAL: $1,301.00 $1,301.00 NEW CONSTRUCTION PERMIT 101-0000-42400 0 $588.29 $588.29 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH Total Paid for NEW CONSTRUCTION PERMIT: $588.29 $588.29 Printed: Wednesday, February 28, 2024 3:39:40 PM 3 of 7 Permit Details City of La Quinta PERMIT NUMBER BRES2015-0092 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,248.12 $1,248.12 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,248.12 $1,248.12 BACKFLOW DEVICE 101-0000-42401 0 $12.09 $12.09 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH BACKFLOW DEVICE PC 101-0000-42600 0 $4.83 $4.83 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH BUILDING SEWER 101-0000-42401 0 $12.09 $12.09 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH BUILDING SEWER PC 101-0000-42600 0 $12.09 $12.09 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH FIXTURE/TRAP 101-0000-42401 0 $253.89 $253.89 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH FIXTURE/TRAP PC 101-0000-42600 0 $253.89 $253.89 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $36.26 $36.26 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $24.17 $24.17 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH WATER HEATER/VENT 101-0000-42401 0 $12.09 $12.09 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH WATER HEATER/VENT PC 101-0000-42600 0 $7.25 $7.25 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.09 $12.09 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.09 $12.09 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH Total Paid for PLUMBING FEES: $652.83 $652.83 SMI - RESIDENTIAL 101-0000-20308 0 $27.45 $27.45 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH Total Paid for STRONG MOTION INSTRUMENTATION SMI: $27.45 $27.45 SINGLE FAMILY DETACHED 224-0000-20320 0 $1,837.44 $1,837.44 7/22/15 R7880 10564 CHECK WPD ENTERPRISES SKH Total Paid for TUMF - RESIDENTIAL: $1,837.44 $1,837.44 Printed: Wednesday, February 28, 2024 3:39:40 PM 4 of 7 Permit Details City of La Quinta PERMIT NUMBER BRES2015-0092 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES GAS RELEASE BLD SEWER CONNECTION KKI 8/27/2015 8/27/2015 UNDERGROUND PLBG KKI 8/27/2015 8/27/2015 FOOTINGS KKI 9/4/2015 9/4/2015 APPROVED ROOF NAIL KKI 9/30/2015 9/30/2015 CANCELED ROOF NAIL KKI 10/7/2015 10/7/2015 APPROVED OKAY TO WRAP KKI 10/16/2015 10/16/2015 APPROVED FRAMING KKI 10/22/2015 10/22/2015 APPROVED ROUGH ELEC KKI 10/22/2015 10/22/2015 APPROVED ROUGH MECH KKI 10/22/2015 10/22/2015 DISAPPROVE D ROUGH PLBG KKI 10/22/2015 10/22/2015 DISAPPROVE D FRAMING KKI 11/4/2015 11/4/2015 APPROVED ROUGH ELEC KKI 11/4/2015 11/4/2015 APPROVED ROUGH MECH KKI 11/4/2015 11/4/2015 APPROVED ROUGH PLBG KKI 11/4/2015 11/4/2015 APPROVED INSULATION KKI 11/9/2015 11/9/2015 APPROVED DRYWALL NAIL KKI 11/16/2015 11/16/2015 DISAPPROVE D LATH KKI 11/16/2015 11/16/2015 DISAPPROVE D DRYWALL NAIL KKI 11/17/2015 11/17/2015 APPROVED TOTALS:$13,382.80 $13,382.80 Printed: Wednesday, February 28, 2024 3:39:40 PM 5 of 7 Permit Details City of La Quinta PERMIT NUMBER BRES2015-0092 BOND INFORMATION LATH KKI 11/17/2015 11/17/2015 APPROVED TEMP USE OF PERM PWR KKI 1/19/2016 1/19/2016 APPROVED GAS LINE/TEST KKI 1/19/2016 1/19/2016 CANCELED GAS LINE/TEST KKI 1/20/2016 1/20/2016 APPROVED PUBLIC WORKS FINAL JPE 2/12/2016 2/12/2016 APPROVED PW Final Monterra Call Mando for pm inspection 1300 to 1330Met superintendent Mondo at site and we walked residenceApproved final - all trenches backfilled - swales are in and back yard drains are in and clean and open - all trash cleaned up.Weather - Clear - Calm - temperature 55 to 88 FINAL**AOR 2/16/2016 2/16/2016 NOT READY GAS LINE/TEST AOR 1/31/2017 1/31/2017 NOT READY SYSTEM NOT ON TEST, REINSPECTION FEE REQUIRED. GAS LINE/TEST JFU 2/3/2017 2/3/2017 APPROVED FINAL**JFU 3/6/2019 3/6/2019 APPROVED CONVERSION FROM MODEL HOME TO PERMANENT SINGLE FAMILY DWELLING. HERS REGISTRATION DATE: 214-N0047610B- M2000002A-M20A REGISTRATION DATE: 6/24/2018 HERS PROVIDER: CALCERTS, INC. REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES FIRE FIRE BUCKET 9/16/2015 9/30/2015 9/21/2015 READY FOR APPROVAL Reviewed by Jacqueline PARENT PROJECTS Printed: Wednesday, February 28, 2024 3:39:40 PM 6 of 7 Permit Details City of La Quinta PERMIT NUMBER BRES2015-0092 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 3/6/2019 DUANE CLAYTON ENERGY DOCUMENTS - CF3R 55119 AUTUMN VALL - ENERGY DOCUMENTS - CF3R.pdf 0 DOC 3/13/2019 DUANE CLAYTON CERTIFICATE OF OCCUPANCY 55119 AUTUMN VALLEY - C OF O.pdf 0 DOC 11/13/2015 LISA NOTTINGHAM LAQ- Monterral_Plan2Model _Lot 35.pdf LAQ- Monterral_Plan2Model _Lot 35.pdf 0 IMAGE 2/12/2016 JIM PETERS looking East from southwest corner of backyard.JPG looking East from southwest corner of backyard.JPG 0 IMAGE 2/12/2016 JIM PETERS looking westerly at front of residence.JPG looking westerly at front of residence.JPG 0 IMAGE 2/12/2016 JIM PETERS looking west at north side yard.JPG looking west at north side yard.JPG 0 IMAGE 2/12/2016 JIM PETERS looking south at rear yard.JPG looking south at rear yard.JPG 0 IMAGE 2/12/2016 JIM PETERS permit 55119 Autumn Valley Ct.JPG permit 55119 Autumn Valley Ct.JPG 0 Printed: Wednesday, February 28, 2024 3:39:40 PM 7 of 7 Permit Details City of La Quinta PERMIT NUMBER BRES2015-0092 Bulletin 006 Rev. 1 13DICRC 313.3 GENERAL NOTES 54TH AVfEN0E Bulletin 135 Ray. L M Model RFC30 (SIN RA0611 ) C. _ 1■III iW+e./e.St� F j m Model RFC SIN RAOSi } F �ars r� ca 'rtacn ""' w."-°fe•°°rn 1. AUTOMATIC FIRE SPRINKLER SYSTEM HAS BEEN DESIGNED TO BE -3 Products INSTALLED IN ACCORDANCE WITH NFPA 13D, 2013 EDITION AND THE Residential $ I � -�Reliabi Model RFC49 (SIN RA0616) a REQUIREMENTS OF RIVERSIDE COUNTY FIRE DEPARTMENT. !�" ��s °' 49 ReSllde�7tlal Flat Concealed �o �• Ms �s HIP and 2_ THIS SPRINKLER SYSTEM SHALL BE TESTED AND INSPECTED BOTH p ■ J a CUECT SITE R Ila Design Den of e015 gp� F ? r�g��Applibadan n�� THE ROUGH AND FINAL INSPECTION PRIOR TO OCCUPANCY BEING tn Sprinklers - Far Ong Atffcs" OTI ED A MINIMUM OF TWO WORKING DAYS 1NGRANTED- THE JURISDICTIONAL FIRE IOAD�ANGE OFFFICE I THLL EE A L REQUESTED INSPECTION. C )LIJ Model F1 Res Spmddem avineaw for the lowest flowvs A Residential i'i iQnt: led General The Specific AppacaNm At11c ape [J] klerb aretrlefiratapralkterat0teIz, •j::- �'; 3. THE INSTALLER SHALL PERFORM ALL REQUIRED ACCEPTANCE TESTS, U) u7 D"c iptio ; • tlwW tar wdendod cwerne In corn- to meet the minimum '�� �`! n of .05 p" * . •t Sprinkler engin far a minimum The TYCO Model Be ($sck to Sacld, baaBblatcnstrucearr. sn(�rrgleaec�onefi,HIP,andAP[nt- - Full-scale wetwWInboulwet and 4. NOTCHING, DRILLING, OR OTHERWISE PENETRATING STRUCTURAL � Types: tcPue�-specicApplkxtlarlspf-veers dry oyalarnacanodos. MEMBERS SHALL BE IN ACCORDANCE WITH CALIFORNIA BUILDING CODE. � Fa- Protect ne Mtha' a^slhe sprkddera - Full-ocift tsstW, for use in wood ':.... 1, F1 des 30 Pendent i design density of 0e05 gpltl with fFx oombuallHe and rwn�oM6r�tlble d°pedatilt waces.The ModolBB. SA a `6O0"°�"�O"' 5. TYPE OF PLASTIC PIPE TO BE CPVC MANUFACTURED BY BLAZEMASTER 2 F1 Res 30 Recessed PendentrF2 1end HIP are specific ApplicaBan Aft • ustsa Oar specific raoralopee (Refer CJ 3 F1 Pau 30 Recessed Pendent FP ; low GPM lejuirlementL sLU 9prinkten,whereasthe l,AadelAPasa taTebbe W U.L. LISTED. pecilcAppication Combumble Con- 171a Spec3#c Application Attc spun- AIRPORT BLVD. � � 4, F1 Res 49 Pendent cad ed Space 3pr0110 having apecfkc k era prrrvlde the tlrret lava of protec- appllceAancMtrlarorlLuaerltnthe tsar, a„d Gam __,. 6- ALL VALVES SHALL HAVE PERMANENTLY AFFIXED SIGN INDICATING n 5 F1 Res 49 Recessed PendenI Fl Features Modes sa su. ww HIP IA sib° the need for addlll131N1 aprinklars a:.., ... ; '"+ _ es. Spedl>e A,ikatbn Zia 3prtdders brenchlina piping. In marry oeseAr an - ITS FUNCTION. � a Isrfae [action in attic ,iris can 1* �' d F1 Res 49 Recessed PendentlFP 1- Very IOW water flew requil emenis. Pro P10 an,�ely f wflh 2 F1 9 i spoon, and when ow%wrad to Stara- jWt 11ne irte of prpilg looelad below 7, F1 Res 58 Pendent 4 , 58&76 Fl Res3g49, 58&75 C01IeC plate attaChrment �Plairl or Rerti�rated� dedSpraySprinlperac°stawlrglealy thepeskoftwroofusingModelB6 I' .. 4' 7. PIPE SHALL BE HUNG FROM STRUCTURAL MEMBER PER THE UNIFORM a F1 Res 58 Recessed PendenLiFl Rec�essedPendentlFl IReces�sed PendentjFP F1 Res 58 HSVr)( + k" a� ��min6t � Il sign r�r ftoo s 'ae1 o' caan�aty a PLUMB4NG CODE. PIPE CLAMPS AND SCREWS ARE MANUFACTURED BY VICINITY MAP 9. Fl Res 58 Recessed Pen P with 1�z �13rrlrn) Total adjustment. Bhhdr.-rhaspecli0Appidation8pnn- aModel HlPspulr> emirs One inavfak AFCON MFG, ARE U-L. LISTED AND ARE INSTALLED ACCORDING TO THE =� Ides Fr1rl'rotactin Attics' have un- lltardthese oiler reurfGarn HANGING REQUIREMENTS IN THEIR TECHNICAL DATA SEE DETAIL 10. F1 Res 76 Pendent 3. Thread-❑n[Thread-Off or Push-On/Thread �, , '' des gwle fiwmset �tene vsfisWating at each area bOV cowaik For aka .r � � N.T.S. ; 11. F1 Res 76 Ftt>Ce3sed Peridant]F1 :-•: = r s �'wlulanloped cap sur�sprinpaom pis,uder9aa ayatem he um in asa fagot ;8`.' w ; Uff cover a taChrTler It option. t 8. THE SPACING AND LOCATION OF SPRINKLERS SHALL CONFORM WITH i �ry r t2. F1 Res 76 Ft+e338d PdndsntlFP ir**; p } 4 app�icatldn guide ne3foruse aepe L as rrgwlde attic, with up to a,212 NiONTERRAi :m..• Oelgprinl0masdefinodbytheNFPA. rodrpltch, deatgnadtothe 2007rdl- THE MANUFACTURES REQUIREMENTS AND THOSE CONTAINED IN ' 13, F1 Res 30OGP Pendent 4. Smooth aesthetic ceiling profile. � , , Th� 6parJicAp�iicatlon Attic eprin- bMr9d* PAls,wpld requlre9even NFPA 13D, 2013 EDITION- TRACT TO FOLLOW brarlcritlee t° cover the matt portion n Ideas provide an edertded corarega thsattic tad several addtlorra: trandr, S s 14. F1 Res 49 CCP Pendarrt :_- 5. Available In brass, chrome and black plated spacing altarnoties to the matdomd PLAN 2 Ilrlae iv cover the n areas• vKtn the �``� ::;• % ' Y• .`,F elleoingof5tan�rd9prmy$p�1r11dera 9pecilrcApplk�ttkrnAtticSprinklera, 9- IF REQUIRED BY A, H.J. THE ALARM INDICATING DEVICE SHALL BE LISTED . 15. F1 Res68 GCP Pendent The restrtrtad spacinngps of standard therequwdcoversyacenbeobfAned FOR OUTSIDE SERVICE AND AUDIBLE FROM THE STREET THAT THE a its. t;� r•.� or cored finishes. Plain Cover Plate SpraySprtldcrsusadwShmalSi�ie wM]uatansllranctdtlenni beVow LOT ADDRESS 16, F1 Res76 MP Pendent � � HOUSE IS ADDRESSED ON. "] $' "��m deeclihad in the 2D07 ad'iiron of NFPA the ek arid and dorm each o 11f 17. F1 Fie8 4.4 HSW 13. Table s-s,a�-1(o) and sectierl the hp beam. Thie would reaun In as 35 55-119 AUTUMN VALLEY CCIJ RT r 113, F1 Re9 4-4 Recessed HSWIF2 Fl Res 3p, n en & 76 F1 Res t1HSWj F1 Res 44 SWC: Listings & Approval i,B.41 4. =Late TKs edu6ti eneedadf - CCP Pendell[ Recessed Fl5W�F2 rustatlatlon. This redractlon h the num- 10. SMOKE DETECTORS TO BE INSTALLED BY OTHERS. LICEI+ISE NO. 684600 19. F1 Res 58 HSW 1. misted by Underwriters Laboratories, and bar a .fft%� °""" `� s o- the pipe. flttinge, harpers, arid asso- Hcriwrrd Sidewal sprirNur3 ciated labor by elrrr11na1ing up five 11. RESIDENTIAL CONCEALED PENDENT SPRINKLERS ARE U.L. LISTED AND CUSTOM, TRACT, MULTIFAMILY 2D. F1 Res 5s HSWX {Figs• 5, 8 $t 7) are eqt ly strrsc- branulhllr - ,. LA QU INTA, CA. ti whenalx113ec tin I certified by UI_ for Canada (cULus� *��: "'- MANUFACTURED BY RELIABLE. INSTALLED AT 16 FT. MAXIMUM SPACING AND COMMERCIAL `21. KRe958 HSWX 9 p•pin9 Cgf' 01 be used_ col wrothw important of the spa- E TECH DA 22. F1 Res 583ISW Reces3edH5W,F2 T1e3mmglsss-hUbpanda ntsprknklerspermitthe alriciar><u9a 000W� ancA oearv,Arn�ker, rral• (SE TA}. AHJ: RIVERSIDE COUNTY FIRE DEPARTMENT 4. vways rarer m Tachn;car Diva °4 ie reduction in ayatam volwne 1 dfreSidenttalVaersu supplies inklacovera in sheerrr��oWifro'; r.�.� '" "°I"s"adu "'"�'awtlnrs- I 12 UPRIGHT INTERMEDIATE TEMP. RF-SIDENTIALSPRINKLERS ARE U.L. DESIGN, ENGINEERING AND 23, F1 Res 4 4 SING PP 9e : : dudrlg 1f1a 11 erne dry mbl &Howfor nine design. �.r•::•::ti:::= : �' ::::::.......a+°-pga„ akccmpreawxJandpdaaibiyaNalvTar LISTED AND MANUFACTURED BY RELIABLE INSTALLED AT 120 SQ.FT. SPACING LEGAL ❑E1�7CRIPTICIV INSTALLATION Listings& App proteCCtion dei3 n. UL Listing Categories (5h " r , roirals , ;, wilhreypac4t°I�ndVrgandirrsia!- qquuf�cl®rwatgrdellverryylt,ea Bllrsnotlrg lSEE TECH. DATA1 • ��� � .. � _•.,_ ktffal or3priMhyrt andCuen- fire need Ta en accelerator. ( ) The IoWirflowFl Rea 9prirklars aespecialry engirlasrad f[rfs9t " 't .:::;705 E. HARRISON ST., SUITE 200 1, Lmled by Underwriters Laboratories Inc. and i r ,;' ;ter „ aef , UL Certified for Canada (cLIL.us) thermal response tcs me€t it►e sarlsrtnae fro pratectlon appiloa- ReSIC �nt#� AUtClt1'latiG Sprinklers t s a spnrAior4y3lem crh 13. PENDENT INTERMEDIATE TEMP. QUICK RESPONSE SPRINKLERS ARE U.L. 7rertsandcwasarherJrdderfofa!! OCCUPANCY: R31 U CORONA, CA928T9 tbn reeds C1 1t'1e Facet residential market standards (UL 11&6 ;, II LISTED AND MANUFACTURED BY RELIABLE INSTALLED AT 15 FT. MAX. SPACING PH-800-815.3473 yr a��&FAft9 4�aYtuedulcrcet4ls SEE TECH. DATA CONSTRUCTION: V-B Smndaro}. Up>;rlfkecondmans,rlangh�tcau�saspr3rader5 UL Gt.11�e Number ,;;•.:' '- � � ( }• FAX - 951-272-2535 Spdnldem for .10 Density; Refer to B LA letin 176 heal i ive elemerr, gIEW bUb ar Grit 10 actuate, releasing the j jKKW STORIES: 1 • �aterwayforwatarf€ warrtothedefledor,svertylao-butingtha 14. PENDENT SPRINKLERS ARE AT LEAST 3 ft. FROM OBSTRUCTIONS E.G. LIGHT BUILDING AREA: 3,743 SQ. P UL Listing Cat cmaoa �1s i F.—n: The recipient le these plans � ��� dt edrvetertocorlrrolafte. �? �•� �-� +-�'� 5- FIXTURES, CEILING FANS, ETC. OR IN ACCORDANCE UVITH TABLE S_2,5.4.2 AND hereby acknowledges that all Posidential Automatic Sprinkler smirg Product Ds'wrip�tiol1 a"3 m : 1 &_.AW SECTION 8.2.5.2- SPRINKLER LOCATIONS FOR CONTINUOUS OBSTRUCTIONS plans, details, Specifications or UL Guide Number Technical Dells: Model RFC3O RFC43 and RFC49 Conceded Residen- ;.,,<,;. � ".'° a _°eN�°r ;:� ARE IN CC7MPLIANCE WITH 8.2.5.4, FIRE SPRINKLER SYSTEM: methods of installation ' ''' DESIGNED AND INSTALLED PER 2d13 NFPA 13D ALL contained in this set of plans is + Thermal Sensor_ Soldered Elemert (Lek) or Nominal lied Sprinklers are fast response residential fusible solder �'� Isn.a �a F a the sole property of Fire VKKW 3rnm glass -bulb �rlk attirbntatiG S{7rir11{I�rs. Residential sprinklers differ h " ''"&' ' "A' w2.9mm) 15, SOFFITS AND CABINETS TO BE PROVIDED WITH SPRINKLER COVERAGE IN RESIDENTIAL WITH A .05 DENSITY WITHIN AREAS. �127Am41) ¢l,e rtap a ACCORDANCE WITH 8.2.5,6, Sprinkler Systems, Inc. and PrAerrts :�R that any use of this set viopaaian sprinlcler Frame. Brass sestina from stgnderd sprinklers prlmariiff in their response time 5 T is prD111bited an is a ,r �a 16. SPARE SPRINKLERS Sr ,��,LL i'=IOT 3E REQUIRED TO BE PROVIDED IN of co rl tic laws wlihoul rigs; US Patent No. 6,516,893 applieslo the MWdeI F1 Res 49 + Sprinklers' PressLre Rating: 175 pst and water distribution patterns. Perforated Cover Prate I 2,x BUILDING SUMMARY p nq 4 6 e p17,Prrrrp ACCORDANCE WITH 5-1.1.1 receiving errrtission from Fire & 58 Pendant Sprinklers Fs�tary Hydrvslaticaily Tested to 500 psi fthodel RFC3[), AFC43 aria RFC49 sprinicters dlscnarge g"s' 7 — --- S rinkier stems. U5 Patent No. 7,353,882 applies to Model F1 Fes 44&5$ . Thread Stze. W' NPT (Flit) water in a hemispherical pattern below the sprinKler de- and positively attached and blends into the ceiling, con- a 1HI� � _ a � �- HSW Sprinkler's Afl3FF US Patent No, 7,784,555 applies to WcIal Fl Res 44 SWC + K rector: 4,9(73.0 ,21 [�,a11-F l RmA 3PuxdacSpidnkl r fectar. Residential distribution patterns are higher and sealing the most dependaols fire proteation available, an 1 ,n. ,� CONCEALED RES. PENDENT SPRINKLER Sprinklers 4.9(7176j(At�lal)-F1Reri4gPeldefTt�Bnlder generally contain a finer droplet size thanstandard sprin- aLtiomatlesprinxiersystem. 7M 6' (19,1 NOWMALVr 5.8 XS) dal)-FIRes56Pendert&i-GWSpr6tlder tier atterns. The EiFC3C, RFG43 and RFC4g are UL Listed Residen- "'"'�4"' tea` ARMS FPAME Product Deeeription r.s(1()9]ij4cttlal)-F1Res7LL Perxi tk P d codas CC) UPRIGHT QUICK RESPONSE SPRINKLER Q Ibdel F1 Res Pendent sprillklers fts. 1, 2, 3, & 4) we fast 44iarj{A�.ie€}-Ft RG976P'1� erI4Er The combination of speed of operation and high dis- tia] Sprinklers to be installed in the residential portions 610"M Mrvm N � ATM response sprrrklersoomUningexcelerwduratZirilq,high 9arrttiv- • tensity, Minimum 0-05 gpmff charge pattern required far residential sprinklers has of any occupancy in accordance with NFPA 13, 13R, & I CONCEALED RES. PENDENT SPRINKLER ty gl -bulb and Imo► p iy rarlle i7 decarmive d�ff��yn The F1 Res dernonstrated, in fire lestinan al)iliiy for Gontrolllng 13D" FtcLIPEF I 1 nGURE E 6 WEL AP WnIf 4.2 or S.e K-FACTOR SPECIFIC residermal fires, and thereby providing significant evacw The RFC30, RFC43 and RFC49 can reduce the need SPECIA4QVU MP FfCAPPL CAVONATTIC�SP WWCLERS A��a"SPACC.ESPRIMXLERS�CEAtE° �} CHANGE IN ELEVATION W stion time for occupants. far precise cutting of drop nipples. The threaded cover AP Technical Qp®ration The Reliable Automatic Sprinkler Co,, Inc., 1D3 Fairview Park Drive, Elmsford. l`�ievvYork 10523 � � RISER LOCATION {PER DETAIL) The RF=C30, RFC43 and RFC49 SprinKlers provide the piste assernvly can be adjusted wiil•]OL1 tOels tG th aC- Installed in the ulx We anemation W& their deflector parallel to the Fool, the gR (K-BA & 4.4. HIP (K;5.9) bestformoftiro protection Dycombiningananractweap- curateiy against the ceiling. The fire protection system Modal APSpnnddA(FigareF)amin- Data &AP(5A1&4JI }(}( NODE POINT FOR CALCULATION handed to be Osed EG prcnlde probmtm Approvals The glass bulb contains a f1u1d that ex- pearance and %" (13m m) of saver adjustment for ease need not be shut cb to adjust or remove the cover of atdc areas outside 1t1g Me of ape UL & C-UL Listed. (Tha approvWa only ponds when exposed to heat, wtw Nta lAicomn for the Ba. s0, or HIP Sprin- apply to the asraNca conditions ]ndl- r d tempararure Is reached• the Ndd of installation. The small diameter cover plate 1s easily plate assembly Iders. When used, the AP Sprinklers cated in the Design Criteria section on expands mi'lidoady to Shatter the glass.HANGER TIC DETAIL Technical sd ai F1 R 6$ 30 Pendent anti Fteces�s t i P en dent (SIN Fl3511 ] wW prarida a hydraulic advantage aver Page 9 end the Dean ouldeirma ime- bulb, allowing the spriral,er to adivate ------------------- -------- ----------- ----- --------------------------- -----------...-------------- -... ---.............. ...... Standard spray sprhxklers icr the pro- lion on Page 8 j and water to Flow. ......................... .....----.........._.._.... _........ .. tactlonofatticarm aitcidathe scvne hived---- Nominal 0011ca fume Prawra r kiarT Rmtkn MM( AmbMant Ton Aaual K Bprlllklfu- Lalygth The Reliable Automatic $ inkler Fairview Park Drive Eirnsford New York 10523 � hcafonlorto BR, SD, °r HIP Pipe BID Ix Co.,s Inc.,iI 1 r p� le link sD ix £ii a 111rh {lrirrt? 1 lhi nr}...._ °E °[" " °C Faletor 1.VL�LwtyAt._... spri la a- if2 inch NPr fqf i(�4 P iA G.6 3r4 inch of t o link rink ea which y la Joined by 'VR" nipr 1f16 !r SYMBOLLEGEND 2i1M" (F3 ?.} 17FS (1 �) 1 7 1 L4} l (4 3, 3I i, 2b (67) otsdmrge C°ereciard iemrpe ah �e Is reached. thus � r - two fin are as rated K - 4.2 PM/psl" 6l1 b LPMfharn its „ (I UFe tw r Ordinary Tonp. Rating Intmrmadida Tamp. Sefing MEnlrrlum MaK.Gavw%War+aca Ap 4i � .................5,1��, �1°�......... .... . ........ ..,,.-,.,,, 07§0 ,,..'.Q......,,,,.,,,,,,,.. Tap of Ddlvldarlo Coiling 8p41dna FtxFtifhxHO Flow ProtiaLlr4 Flow Prlamuro Irl4himnU . PM(I-hnin) P9i (bad QPM (UmW PSI (bar) .__._..._. .__._._.._._.._.. ..__.._..... ._.___._._..._._....._._...._._ Ft (m} ...._._._....... 1$ x 12 (3,t3 x 3:A } f $ 3 £a ( ) 8 t�,3 7,D 4,ti8 41 ) { ) R 3 l 6,4R pu' ] ( ) 9rn"h C*llirtpi 1141a4 ;31,7to 102) lvnirig F2escu[ctrlxirI. .,,,,,.,,,.,,,_.-„e,,,,,- ...... .,,,.,,,,,,,,.,,,,,,._- W„_. .,,.,,,_--"-cow ,,,„_-,,,.,� _,� ,,, .,,, ,.,._...._-,.,, „�„_„_,.._.,„ -. a.m d Ceifir16s per NFPA 13D, 13f? C (2,4) 14 x 14 (4,3 x a,5] 14(4.3) 10 (",37,8] 11(0,76) 6) 10 (37,B) 11 (0,76) or 13 iVal Isd uT bmws tl4 io IN . 1 7 t<s A4.d Leon F'1dte,c:I�r.Yt<surt I�mr Coz-fling tylxs reforto I•tI"PA 13, 18A or 130 Technical Data: F1Res 4a Pendent and Recessed pendent (SIN R3516) Thread Nominal Orilice Max, Sprinkler Max. Actual Sprinkler Size Irish (mm] Prewure 7errlp. Rating- _--Ambient_ Temp_ K Lealglh -�F- °O Factor_.... knCh��- ':�°iNPT R is rl„'(]1} ITS '12) 1f6 175 S£if ra ^1"rkt 1 1y, -- 4 Vr'.G; _ 2.25(57) Ordirtary Temp. Reding Irdermediate Temp. Rat€ng le Top of Deflector itf1lr11mum Mo(. Couere ge area Max. Spacing '155°F16890 11U179-C to Cell! ill n) SpLimu do Flow Pressure Flow Pressure R x Ft (m x M) R (m) .._........_... ............ _.._................. -._........ _......._.. _GF?@l11L�In} Phi_{bara� GPNt [Jm�n� ..._.�.�I�f?_ finish Ft SlrloM-i Ceilings 11,4tc 4 (31.7 W 102) using FZ esaitcrieurl. 1? x =2 (3,E x 3,6) 12 (3,6) 13 (49) 7.0 p'413) 1.s (49i 7 r; (u tg] 14 x 14 (4,3 x 4,3) 14(4,3) '8 (4V 7.0 (0,48) 13 ;49) 70 (G,4E) 1 to G (25.4to 102) using F1 aacutct�e�or:. Foa l Cedings par NFPA 8(2.4) 16x 16 (4,9 x u,9) 16 (4 �)) :;l (48) 7.0 (V,4 3) 13 (49) 7 Ci (C,4G) - - - ---•----•--- -- ------ 130. 13R 01 131nstalied rl 18 x 18 (5,6 x E:5) 18 (w,�} 17 (64,3) 12 (0,83) 1'7 (64.3) 12 Y%0:83) Warns 1'�a tO IJ4 (31 710 44 4) iisrrt0 F2 EEiCiJtGhe f, 1 2L'x20(6,1xG,1) 20(6•1) 20(75,7) 15.7(1,14) 20(7l;,7) 16,7(1,14) to13£(25.4to44.41usingFl _-_-._-._. ...._..�.._ _.__.. ....._ ....._-- esculcriaon.- Model Thread Nrsminai Sprinkler p GCP Assembly y Max. Ambient � Max. (SIN) Size Orifice Temp Ratio p 9 Temp. Rating P• 9 Temp. c Factor Pressure Inch (mm) Inch (mm) psi ( bar) OF °C OF cc OF cc pC RFC 3{% (RA0611) 1 A„ (15) 21 X. (S•`"% 1 '�: � 74 135 ,r', 7 100 38 3.0 �43.21 175 (12) RFC 43 [RAt1S12) 61 12"'15} 8 (i'a) 1G6 74 185 57 100 38 4.3(132) 175 (12) RFC 49 [RA0616) 'rl"7�,0 (11] 165 i4 '35 57 1� � 4.L1 (70.6) 175 (t2) wie. i oar 1 uu mpa RFC 30 Ordinary Temp. Rating Max. Coverage Max. Spacing (1659F174°C) To W Deitlecter p Installation Minimum area Ft x Ft (m x m) Ft (m] to Celling Inch (mm) Type Spacing Ft (m) Flow Pressure GPH1 {Vein) PSI(bar) Concealed x:.,2 i':'5 x :.,I.ij 12 (3,6) 9(34,1) 9.0 fOr621 Smooth Ceilings Yu to 1(13 to 25.4-) Beamed Ceilings per 'NFPA 13D, 1 ❑i- 8(2,4) - — 1 x 14 (d,3x 4,3; t4?4, i) 1C (;,7,cs) 11,:i (a,76) 13 installed 1r1 bUams V. ti 1113 ro 25.4) _,__......-..-._.. _..._ F . r ., , , rzr ?:, ,'irr.g lypg° refer to NFPA 13, 13R o- =317 �i 11 fig �Y�;�S r�tEir 1G NFPA 1. a. F r;: 1.�Fj WRFC 4a ordinary Temp. Rating Max. Coverage Max. Spacing (1fi5°%I7�1°G) Top ❑f Deflector ion Minimumlnstaliat area Ft x Ft (m x m] Ft (m) to selling Inch {mm] Type Spacing Ft (art) I Flow Pressure GPM (Vmin) PSI (bar) 12 x 12 (3,6 x 3,6) 12 (3,6) 1:2 (4,5) 7.8 (0,54) i 14x 14 (4,3 x 4,3) 14 (4,3) 13 (49) 9.1 (O,G3) om7r}tT Ce lingrs 3�. tti 1('3 to 25.4) 16 x 16 (4,9 x 4,9) 16(4.9) 13 (49) 9.1 ('",63) Beamed CelLngc per NFPA l30, 1 SR rr 13 irstalled in Reams Y2 to 1 (13 to 25.4) Concealed L 8 (2_A) 18x 18(5,5x5,5) 18( ,5j 18(e8) 17.5(1,21) 20x20(5,1 x 3,1) 20(6,1) 21 (79) 2a6(1,64) K 1.6 r3PMl 5,1+ OD,P, LPMfbar19 allorvin a ink helves Sapara(e, K-8.D GP �' {115,5 LPM bar.) 9 sWinlder to activate and Wow to flow_ . a Te„,po,p b„e Ram IrltarF/8ateTemparsWress Howes {"irB -200`F136"Cacr 6{1{A.231(B.0}, RIVeI'S4CtB Ci3Ltti`r HIP, AP LU -212'FftDD'C for BB (K5.% 9p MaTShal 1100El K SIN ALLOWam c ROOF SPAN' (a)1h1 W Feat (m MINIMUM FL13W, 6P14 pp;N MINIMUM PRE"Lift PSI 00 , -er R Rise Urea Run I%] , DRY M PE sn"M MA)WUM WATER DELIVERY 71IAE second: .. a_D 8.0 TY4lw 580 (16,3) 38 0" 1 22-0 (1,61 412 [33] to hoe then 7:12 (56y I-) BB2 s0 TY418: :M (18,4 39 (144] 2m (1.N 7_12 M to lon then 1012 (931 W BB3 a n TY41 s2 WO (18.3) 4o 0" 25-0 (t,7) 10-12 Qq W 12:12 000) (c1 Sal 5.5 TY3160 a4002,2)1.00(18A SS(144) 46.0(3.2) 4:12(3s)10ion r1an7:12M (ai BB2 S9 TY3181 >40 n 2,2110 60 [16.9) 36 n44f 48.0 (8.2) 7:12 Mgto leas than 10:12 [O:i) (c) 8133 ar TYa1&2 a40 ti2,2i to 60 (18A 36 044i 40.0 (3.2) 16-12 (B3) tc 12.-12 t+im7 (°) Del Sa rMad s40 (i2,2) 25 (951 2MO (1,4) C12 PM to lass than 7:12 (5e) (� eel 5.9 T1r3111i s40(12,2) 2hmb) 20.011,4) 7.i2(5a]toIMP ffaIM2(93) B&3 545 TYM82 :C 0(12A 25 W 20.0 p.,I) lit12 (83)1012:12 ouoj Ia1 flat 4.2 TY2180 s20O,1j 13 (4 0.6 (0,7) 3,;12 (251 to tasa than 7:12 (5% 45 (d) BW 4.2 7Y2191 c20 0,1) 1a i461 9.0 (0,7) 7:12 (58) to- lase the-101:? [e3] 45 (d) ana 4.2 1 TYZW S29(8,1} ism 9b(0.7i 10:12 OM to 12:12 (10f71 450 SDI 6.6: TYM93 a 36(9,1)tod40(12,2) 35 M2i 39.0(2,7) 4:12 i33) to leas than T.12(66) 902 $.6 TY3184 s90 {a,1] to s40 (12,2) 35 (134 n.0 (2,71 7:12 (SM W lead than 10,12 P] {c) 9119 L.8 TY34&S x90{0,t] to c40 (12,2) 55 032) 39.0 (2,7) 10:12 (83) to 1x12 (100) {cj SD1 &IS TY3189 10 j3,0) to KS0 (9L1) 25 {95) 20.0 n,4j 4:12 L33) to Imo than T.12 M IQ SW &a TY3184 a10 fa.u) W s30 (9,1) 25" 2d0 (.4) 7:12I5e) to lose "n iM12 j83) A SM 516 TM55 a10 {;3,0) f° saD (9,1i 25 ft MS 0.4) 10:12 (83)to 12:12 (1 Wl 10 SDI rah 7Y0188 8lopaC) 19(721 Its(6,S) 4,12(33)tohwthen 7:12ON ha 862 5.9 TY3184 S 10 (3,0) 14 rM 1t•5 (OA) T.12 [56] tc lass Wen 10t12 M SD3 &S I TY31e6 00(3,0) 19(72i 7F.5(0,8j Ia:12(83)to12:12000j jrq HIP 6.e TY31137 a20ISM to 52e Kb) u r 1_ 8&.a t2-6) 4,12 [33] to 12:12 (IM M HIP 5.6 7Y3187 520 M.1) 23" 27-011,4) 4:12 Do to 12:12 (low M AP Ca 1'Y31e0 t0[3,1W2(s,Wy _see row 0 mumO.lOgP aq.f f 'C:i rgW+y1Z;14(1001 Id t mmufirina pesign Denelty 3:12 R51 m 12r12 (100) 00[d1 AP 4.2 TY41>m e0 (d) NOTES; (a) The Ba and 8D roe span rs measured horizontally Oat Bang ins slope] as shmri fn Rog I and 2. Oil The HIP roof span is m wad hom onts6y as sh° in rpum 12. (c) Rafw to W)7 eddflon of WIRA 13, Section 72.9. {cg Mexirrwm ,w;ar delivery time for 4i sag d eavlsms. (e) 7be AP rootspan is rtteaaursd afong the slope. Maximum 10 feet al m) papwo4tl arta slops by maxvnum 12 feel0.0 mi Ms." to Mpa ()fftce Ot [Fie Fil D7 SEP 16 F�1 Re eiv d By , ■ Uj w APPROVAL FIRE DEPARTMENT RIVERSIDE ' FSS CASE# 14 L DATE: _11jkLt1Z54 THE FI DE APPROVAL FOR PLANS IS VAL10 FOR ONE YEAR -SUBJECT TO L] U_ COMPLIANCE WITH APPLICA13LE CODES LU L I Z 1J (9 m � a_ APPROVAL STAMP C3 d � Ln rn � r ten ELEV. HYDRAULIC SYSTEM PRESSURE REGULATOR CPVCTs7SYSTEM— *FOR REFERENCE ONLY � JOB No: 31335 TO BE SET AT sa PSI DR E 91151'f 5 Po C.eiling types refr�r to NFPA 13, i 3R or 130 : This Building is Protected by a TO DOMESTIC WATER SPARE SPRINKLERS SHALL " DRAWN BY- EC RFC 49 Hydraulically Designed CONTROL VALVE FOR DOMESTIC NOT BE REQUIRED TO 5 GPM ALLOWANCE PROVIDED PER 5.1.1.1 €Nax. Ca4erage Ordinary Temp. Rating Tip of Deflector Minimum area Max. Spacing - 1B5°F174°C) to selling installation Spacing Ft x Ft (m x in) Ft (rrtj FICr;N Pressure [rich (mm) Type Ft (m] GPM (L/min) ar PSI b 12 x 12 (3,6 x a6j 12(3,(3) 13(49) 1 -10a (0,48) 5mgcot: Ceilings lb- to 1 (13 LC 25.4) 14 x 14 (4,3 x 4,31 14(4.3) 13 (49) 7.0 {0,48) 15 x 16 (4,9 x 4, if 16 (4.9) 13 (49) 7 0 (0,46) seamed „e:I Tgs par NFPA 130, 13R cr 13 Irtsta iGd In Y La 1 (13 to 25.4) cmcealer: 8 (2,4) 18 x 181,5,5 x 5, 5) 1 r3 (;,51 1'7 (64,3) 12 ` p'83) 20 x 20 (6,1 x 13. V 20(6,1) 20(75,73) 16.7(1,14) Automatic Sprinkler System. } ON �o��� Date Installed 9115115 GAUGE4 1" CPVC RISER Q l Location CALL AREA 2 2' ELEV. 14-112 x 30 �- ACCESS DOOR CLAS TION , Number of Sprinklers 2 >ss Basis of Design 1121, MAIN DRA N VALVE * 6 tS �9�• 1. DENSITY .05 gpmlSq tt. FINISH GRADE DRAIN TO EXTERIOR STATIC 88.24 -10°k = 7PSI �`� OF AL ,`Kd 2. DESIGNED AREA OF DISCHARGE p' ELEV. C RESIDUAL 86.33 -10M = 77,697,69 PSI 512 5 .ft. I" COPPER L 1" METER RUBBER FACED CH GK VALVE,,, FLOW 2500 GPM For Ceil"rig ty;)es+a#er to NFPA M, 13R cr 130 System Demand 3 PSI LOSS PSI LOSS WATER FLOW INFORMATION SIZE • 24" X 36" Ir 1. WATER FLOW RATE 31.43 9prin 1/x' PVC 1" COPPER K 2. RESIDUAL PRESSURE AT THE r� SCALE U G � METER N.T.S. BASE OF THE RISER 36.2 psi 70' MAX MT 30 MAX ALL WORK FOR FIRE SPRINKLER d -2'ELEV. BC)R SYSTEMS, INC. TO BEGIN AT B.O.R. IF SHEET 15 LESS THAN Installed By Fire Sprinkler Systems, Inc.-2' ELEV 24 k 3PRIN SCALE UCE❑ -2' ELEV. REDUCE ACCORDINGLY SHEET ID HYDRAULIC NAMEPLATE UNDERGROUND DETAIL RISER DETAIL PLAN GENERAL NDTi=S N.T.S. N.T.S. (FOR REFERENCE ONLY) N,T.S, SHEETFP10FFP3 -44i1 i BATH'S 19'-I} CLG -- - i 14 r'-i 0- ti BATH 3 i-HR. AND 2-HR. GYPSUM WALL ASSEMBLY 1 OR 2 HOUR FIRE RATED THROUGH PENETRATION RRESTOP FOR SINGLE PLASTIC PIPE THROUGH GYPSUM WALLS USING BLAZEMASTER CAULK & WALK F RATING = I-HR. AND 2-HR. T RATING = i-HR. AND 2-HR. DRAWING NOT TO SCALE i. PRE -RATE D GYPSUM WALLBOARDISTUD WALL ASSEMBLY A) THE F RATING =1 HOUR IF THERE IS ONE LAYER OF GYPSUM WALLBOARD. B}THE F RATING = 2jRHOUR IF THERE ARE TWO LAYERS OF GYPSUM WALLBOARD. 2. PLASTIC PIPE BkN M2' LAR SPACE RANGE SHALL 08E � 4? Tl7 MAX 1 31gPfPE B NOM.4' DAM. (O SMALLER CPVC PIPE. NOTE: FOR USE JN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. 3. BLAZEMAST ER CAULK & WALK - MIN. 112' THICKNESS OF SEALANT APPLIED WITHIN OPENING. ADDITIONAL Sf_ALAINT TO BE INSTALLED SUCH THAT A MIN, 1 /4' CROWN IS FORMED AROUND THE PENETRATING ITEM. NOTE: THE F & T RATINGS OF THE SYSTEM IS EQUAL TO THE FIRE RATING OF THE WALL ASSEMBLY, ULIcLIL SYSTEM NO. W1215i RISER LOCATION FLOOR SPRINKLER PLAN SCALE: 114" _ � I-dn January Z005 Garage Installation Specifications stialf only apply for the imlallatlon of UL Listed BlazeMasteFa CPVC pipe and fittings in garages requiring sprinkler proledon per NFPA 130 and NFPA 13Ft. these Standards are defined in NFPA codes entidcd'One and Two Family Dwellings and Mobile Homes' and irt'Resldettial Occupancies up to FourStorles in Height. AS referenced in NFPA 13D Section 8,5.4,'Sprinlders are not required in garages, open attached porches, carporls or similar structures' The installation of TFP SIazeMaster sprinkierpipe and fittings for use in garages requiring sprinkler proleclinn per NFPA 13R is only applicable to the UL Listing of this product. Requirements for Pipe, FlOings, Solvent Cement Systems, System Design. Installation, Freeze Protection, and Penetrating Fire Related Walls and Partitions are covered in this installation and technical handbook. Please read these sections of the manual caretully prior to designing or installing TFP 61azeMa9ter pipe and fittings far garage installations. The Installation of TFP elazaNMaster pipe and fittings In garages requiring sprinklers Is oily UL Listed and is not C-UL Listed, • Installation Requirements Protectiiow TFP BlazeMaster CPVC pipe and fillings shall be installed concealed behind protection consisting of a minimum of one layer of % thick gypsum wallboard or'I4 thick plywood. Sprinkler Requirements: UL Listed, 4VICk response, standard coverage, pendent or sidewall sprinklers with a 225°F It 07'C) maximum tempafattlre taling shall he utili2ed, All sprinklers shall be installed per the manufacturer's published installation instructions. Installation Standard: The Listing far Garage Installations shall pertain to those occupancies defined by !NFPA 13R. artem Rlsers in accordance with the UL Listing, TFP BlazeMaster CPVC pipe and fittings may he used as system risers in accordance with NFPA 13, 130 and 13R when subject 10 the following additi o nal Ii m Itations: 1. When Installed protected (concealed) in accordance with NFPA 130 and 13R, the minimum protection shall consist of either one layer of Va' (9.5 mm) thick gypsum wallboard or'!:' (12.7 mm) thick plywood. 2. When installed without protection (exposed) in accordance with NFPA 13,13D and 13R. the following limitations shall apply: The risershall be installed below a smooth, flat, horizontal ceiling construction. A Listed residential pendent sprinkler is to be Installed with Its detleCtar at the distance from the ceifing specified in the sprinkler Listing. OR The riser shall be installed below a horizontal unfinished basement ceiling (in accordance with NFPA I3D) constructed utihang nominal 2' x 10" ar nominal 2' x 12" exposed solid woad joists on 18' centers. A Listed residential pendent sprinkler is to be instalied with its collector a maximum at III. below the bottom of the solid wood joist in anticipation of future installation of a finished ceiling. When installing TFP BlateMaster CPVC pipe and fittings in eonjunclion with 2' x 12' solid wood joists, the maximum syslem working pressure under Rowing conditions ' shall not exceed 100 psi and the maximum system working pressure under static {nonflowing) conditods shall nol exceed 175 psi. The Listed residential pendent sptrinkleF is.te ha+u 155"F $8-0) maximum i temperature rating and is to be installed at a maximum honzontaJ distance of 12 inches from the center line of the riser The system is to be designed based upon the Listed flows for the sprinkler selected except that the flow for a single sprinkler or multiple sprinklers shall not be less than 11 g9m per sprinkler. Table R One Faint of Restraint I MAX, N1Ax. doe -faint vertical Restraint 'RESTRAIfNT r��r� STRAINT ONE -POINT vE-POIiNT Nominal aRr, r.R,r Pipe Star= Less than Greater titan ANSI trtches i(3R psi 1D4 psi lJN {6,9 bar) [[3,9 tear) 3i4 0'-9" D'-6" Dfd2p {D,23 �) fQ,i� �,) 1-if4 1'-4" 1'-D" DN40 - DN8❑ {D,6� m} (p,30 m} Table S • Two Points of Restraint Nrsrrlinat Pipe '=g:, ,rs„ Size Less Than Greater than ANSI inches 1+30 psi it}D psi DIN {6,9 bars {G"S tear] 3/4 a' -a" s'-a" DJN20 {1,22 m}, (0,91 n1) DN25 (1,52 In} (1,22 m) DN32 {1;83 rrl} (1,52 lit) DN40 _ F1� IBEi (2.13 rrr) [2,13 m)- }.� S Two -point, ANY 0€STAIVGt7 -ice---� Vertical F#estrarrlt i FtE57€?AfNT TWO, -POINT FfauRe rrs EarPosFa cPtrc WITfi AP SPRINKLERS AND BRANCriLr1VE OVER JOISTS 9PRWla.ER � to,fl mj w eRAl4 8' MIN. 19' T.fIN. _I r 12' MIN. l A�t � R-n, Y■ SIZE - 314" lhru 2' pipe MATERIAL - Carbon Sleet FI N1SR - Mil Gah awsd LISTINGS - UL Listed: EH 4291, Ex 2551 PATENT - No. 9,945,279 FUNCTION- To support horizontal piping- CPVC. Copper or 5{ l ) A listed hanger m all 3 mvunling position, i.e. side of vertical surface and bolh topside and underside cif ticeizornal surtaoe. A kated mtrainer providing wrtioai and Inter restraint in all the abore maunliog positions. To prevent upward movenaerr, or pipe that supplies a pendent spnnkler ° below the ceifing. To Sabilize ventral piping by providing honidntal rasuglnt. T INVALLA'PON - Per NFPA I ag. cslmw by pipe type. Install on woad, concrete or steel. Restfal"I Snap over pipe, then squeeze strap back aUmmng pipe to slide Freely. When 0 905 threads are exposed in wood, insal l #908 backing nut. FASTENERS- UL Listed per NFPA 13 -yyppp� CPVC pipe - C9o5 sue. - no pro-dnll Copper pipe - e905 screw - no pro drill Steal pipe - 114"x5 1!2" lag xSew - no pro -drill R--. Tnw 5ia" gypsum board - iANT lag straw UL Listed per NFPA 13 - mm IS GA 'STEEL' CPVC pipe - 114' or 014 Tek Screw Capper pipe - 1 W or #14 Tek Screw Sleet pipe - 114" or 414 TeK 8cmw •CPNCRETE' Required minimum load each fastener The higher or 170 LAs or 5NwfJ+250Poa z F EATIJ RES • ' 1 V2' Oft.(- pipe wan to rn-t g s�faoe 314" and 1"pipe Mae made with con -w Qwter-`ane • leg de agn produces superior atrength 'Offset a4e eliminates abrasion ' AFCON #905 screw 71sted for wood nas 5-1W Ron head - induded OR DE RI NO - Pan S and pipe sire Nominal Pipe Size (in.) 33/:, 1" 1Y" 1W 2" 2,1" 3" 311" 4- 6. 6" 8" Steel pipe except threaded NIA 12'-0' 12'-0" 15'-0' 15'-0' 1 V-O' 15'-D" 16-0" 19-0" 151-0" 16-0' 15'-0" lightwall Threaded lightwall steel NIA 12'-0" 12'-0" 12'-0" 12'-0' 12'-0" 12'-0" NIA NIA NIA NIA NIA pipe Capper tube 8'-D" 8'4' 10'-0' 10'-0" 12'-D" 12'-0" 1 Z-O' 15 -T 15'-0" 16-M 15'4" IF-0-- CPVC T-6" 6'-D" V-6- 7'-0" 8'-V V-0" IY4-0 NIA NIA NIA NIA NIA Polybutylene (IPS) NIA 3-9' 4'-7" 5'-0" 5'-11" NIA NIA NIA NIA NIA NIA NIA Polybutylene (CT5) 2'-11" 3'-4" T-11" 4'-5' S' 5' NIA NIA WA NIA NIA NIA NIA Ductile Iron pipe NIA NIA NIA NIA NIA 16-0' IN% NIA 15'-0" NIA 15'-D' 15'-D" 1 ,I SIZE & PIPE TYPE - LISTINGS - FASTENERS - In WOOD: in STEEL .' . STEEL - COPPER - C.P.V C. HANGER NOT TO SCALE $ B A f --,1,7) I 314" THf2U 3" C.P.V-G. PIPE UL LISTED, EX 4231, EX 2551 INSTALLATION -PER NFPA 13D INSTALL ON TOP, BOTTOM OR SIDE OF BUILDING ELEiv SPACE BY PIPE TYPE 314" - 3" CPVC PIPE - #905 SCREW - NO PRE -GRILL 3I4" - 3" CPVC PIPE - 1I4" DR #14 7EK SCREW 510 Nominal Pipe 512>e (in.) 1'/" 1'/:" z" 2%. 3. 3,�» a. S. V. 8. Steel pipe except threaded NIA 12'-0" 12'-0' 15'•0' 15-0" 15'-0' 151-0" 15-0' 164" 15-0' 15'-0" 15'-0" iightwap Threaded 8ghtwall steel NIA 12'4" 12'-0" 12'-0" 17-0" 12'-0" 12'-0" NIA NIA NIA NIA NIA pipe Copper tub® ti'-D" 8'-0" 1D'-0" 10'-0" 12'-0" 12'-0" 12'-0" 15'-0" 15'-Q' 154" 15'-0` 15'-0" CPVC 6-fi" 6'-0" 6'-S" 7'-0' t3'-17 9-0" 14'-0" NIA NIA NIA NIA NIA Polybutylene (IP5) NIA 3'-9" 4'-7" 5'-0' S'-11" NIA NIA NIA NIA NIA NIA NIA Polybutylene (CTS) 2'-11" 3'-4" 3'-11" 4'S' S'S' NIA NIA NIA NIA NIA [NIA NIA Ductile iron pipe NIA NIA NIA NIA NIA 15'-0" NIA NIA 15'-0` NIA 15'-0" 15'-0" T 9PRINxLER I AP11r-0• MVL sPRtc p rJOiST ml ;1 5¢,4mmj WNW _ I I 12' M1N STEEL -. COPPER - C.P. VC. HANGER NOT TO SCALE OVDON ars„�IriNY ruH +IHt PAOTE-.TON CF CPVC CEILING IRSl1L4T1CH FOR FIRE PROTECTION OF CPVC I�ZJUMO PIPE NOT FREEZE PIPE, NOT FREEZE PAaTEcrraR RAOTEcnaN OPr10NA OPTION a � (0� SPRIHICLHI ru, ,o•o•Max VFW� .ar SPRKi Ca,O mJ SPRIG FFGIrRE 17l3 sxPosEn cPvv WITH RP SPRINKLERS A1VP JaeT " dolsr BRAIJCFILINE WfrHrld JOISTS tl' MIN. 1 NCiNi:OhABI:STIBLE p 52,a mmJ ::Nsurlm0}; raR FIRE UPRIGHT ti' MIN. ! NON4OOT,19lJST1BLE (t52,4 mm} INSUL4nON FOR FIRE 'PROTECTION OFCPVC PROTECTON OF CPVC PIPE, NC)T FRCrIs PIPS NDT FFl� GEK.1N9 PROTECT1aFF CEILING PROIEGIIOH OPTION A 9 HEAD TO F.A.U. DETAIL N.T.S. FLOOR AREA - 3,220 SQ. FT. GARAGE AREA- 523 SQ. FT. DESIGN AND INSTALLATION SHALL CONFORM TO NFPA 13D, 2413 ED- NOTEs; 1. ALL HEAD SPACING TO BE 16'x1$', UNLESS OTHERWISE NOTED. 2. ALL PIPES TO 13E a�;'CPVC, UNLESS OTHERWISE NOTED. 3- PIPE CLEARANCES MUST BE IN ACCORDANCE WITH NFPA 13-9-3-4, 4. HANGERS SHOWN FOR REFERENCE PURPOSES ONLY. HANGER SPACING TO BE PER TABLES ON THIS SHEET. 5, UPRIGHT PROTECTION TO 8E PROVIDED AT ANY FAU WITHIN THE: ATTIC. RISER PIPE AND FITTINGS TO BE $�" CPVC WHICH WILL BE INSULATED ALL AROUND. fi. ALL PIPING INSTALLED WITHIN THE ATTIC SHALL BE PROVIDED WITH MIN. $" INSULATION ON THE ATTIC SIDE OF THE PIPING TO AVOID EXPOSURE OF THE PIPING TO TEMPERATURES IN EXCESS OF THE PIPES RATED TEMPERATURE (2013 NFPA 13❑ 7.7), 7. SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55sgft, AND LESS. (SECTION 8.6.2.) S. SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THAT MEET ALL OF THE FOLLOWING REQUIREMENTS' (1) THE AREA OF THE SPACE DOES NOT EXCEED 24sgft. [2] THE LEAST DIMENSION DOES NO EXCEED aft. (3) THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE DR LIMITED -COMBUSTIBLE MATERIALS AS DEFINED IN NFPA 224. 9. 8.2.5.3.2 THE DISTANCE SHALL BE=MEASURED FROM THE CENTER OF THE SPRINKLER TO THE CENTER OF THE OBSTRUCTION. 14, 8.2.5.7 SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS L-ONG AS THE CUMULATIVE DRY AREA DO NOT EXCEED 15sgft (1.4 sqm) PER SPRINKLER. s d [!s w it • LICENSE NO. 684600 • CUSTOM, TRACT, MULTI -FAMILY AND COMMERCIAL • LIESIGIN, ENGINEERING AND INSTALLATION • 705 E. HARRISON sT., SUITE Boa CORONA, GA 92879 PH - 800-915-3473 FAx - 951-272-2535 i The recipient of these plans hereby acknowledges that all plans, details , specifications or methods �S1r Inst3allsttisll contained in this set of plans is the sake property of Fire Sprinkler Systems, Inc. and that any use of this set of plans is prohibited and is a violation of copyright lawswithout first receiving permission from Fire tCY o PCL CLO rr Cr , ZQ N r.77 N C V U L.L w ¢ � Lra -J LLJ ca r. JOB NO: 31335 DATE: 9115115 DRAWN BY: EC C, SIZE NO. F CAL - 24" x 36` SCALE il4"=1' IF SHEET IS LESS THAN 24" X 36" IT IS A REDUCED PRINT SCALE REDUCE ACCORDINGLY SHEET ID PLAN 2 FIRE SPRINKLER PLAN SHEET FP2 OF FP3 Z Residential Connection Charge Estimate Date: September 3, 2015 Customer Name: La Quinta Housing 1, LLC Phone No. (949) 689-4388 Parcel No. 767-860-035 Geo. 06-07-15-4 Address: 55119 Autumn Valley Ct., La Quinta LID: 670400 Block No. Lot No. 35 Size of lot: 10,454 sq. ft. Tract No. 32742 Type of Service: R-1: 0 Duplex: ❑ Triplex: ❑ Apts: ❑ SWSC: $ - Acres: 0 SWSC: $12,218.00 /acre WSBFC: $ _ SCC: $ 4,851.00 Treatment: $2,436/edu Collection: $2,415/edu Meter: $ 400.00 Meter size: 1 inch Meter surcharge: $ 2,479.00 service size: 1 inch Service: $ - Meter & Service: $ _ Backflow: $ _ Other: $ - (see explanation below) Sewer lateral: $ Total: $ 7,730.00 Other: Abandon / Relocate Information Supplied By Customer 71 CVWD System Data Domestic Water Demand* Service Connection** Max. Flow= 32 gpm Max. Flow*= 32 gpm Min. Pressure= 60 psi Inlet Pressure 1= S6 psi Fire Sprinkler Demand* Outlet Pressure= 59 psi Max. Flow= 31 gpm Min. Pressure= 38.5 psi Meter Size = 1 inch 5 stem Type: Service Size= 1 inch Multi El Alone ❑ 1 Prior to Pressure Regulating Valve ** For Calculation Purposes- Service Connection Includes: * CVWD USES WORST CASE CONDITION Service Connection Pipe=50', Meter Stop, Meter, Check Valve & Shut Off Valve Notes: Tract 32742 Monterra. Special Agreement, Credit on WSBFC, billed all SWSC 14.21 acres on lot 34, collect all SCC. Per CVWD approved dwg 40762 a 1" service exists and per dwg 40759, a lateral. Pz 15-6602. Technician: Sara Lopez Approved by: Date: fH- /,5,9/3/2015 cvwd-950 ii�e* f11Il1TC •all fnnr -.rn r.� ....*�.. /`L.-.......######### ..._ ...,. — Z Domestic Water System Flow Analysis j Domestic Water System Flow Analysis (Hydraulic Model) Coachella Valley Water District 75515 Hovley Lane East Palm Desert, CA 92211 Requested By: Fire Sprnkler Systems, Inc: Date: 06/09/15 Address: 705 E. Harrison St. Corona, CA 92879 APN: Req. Fire Flow: gpm at 20psi for hours. Contact Name: Jamie Biship Project Name: Monterra Phone: 800-915-3473 Email: jamieb@fireinc.net Cell: Domestic Water System Flow Analysis Location: Flow Analysis on Hydrant located between 61-675 & 81-685 Brown Deer Park, La Quinta. PZ 15-6412, WFAS2070, Technician: Sara Lopez Plat s6da Model information Flow Analysis Description MAID Domestic Requested 1 I Test 2 Test 3 Test 4 Flow CVWD 2015 Model - PDD DomesticTest system flow available without exceeding CVWD criteria. Elevation (Ft): -29 88.24 86.33 -29 88.24 86.33 Steady State, Dynamic (psi): Residual Pressure (psi): Fire Flow Tested (gpm): 2500 3000 N/A Combined Total: N/A Model Junctions: One new testluction used to simulate hydrant -J1738 Duration: 3hours Demand Conditions: ESP Peak Day Demand (PDD) Reservoir No./Level (s): Res6726/51.26.73 Pumps Operating No's: Pumps On Pressure Zone and HGL: Lake Cahuilla Pressure Zone (HGL 145' Model: I ESP 2015 Domestic Water Hydraulic Model (24hr) Comments: Several domestic water hydraulic model runs were performed at the requested location. There Is an existing 18- inch diameter domestic waterline located In Brown Deer Park. The domestic water system Is capable of providing 3DOOgpm for 3 hours at a minimum pressure of 20psi that satisfies CVWD's minimum pressure, velocity and/or head loss criteria's. This simulated system flow analysis may not Include all facilities that may be required for this development/project. In addition, future project phases may affect the results. Please check with Development Service for further information on all required facilities. These results are based on hydraulic modelling and not a guarantee that CVWD's domestic water system will have the capacity to supply water to the project at the flows or pressures indicated. It is important to note that the capacity of the on -site fire system, meters, service lines, backflow assemblies and other appurtenances were not considered in this analysis, which may alter actual flows or pressures. Due to continuous changes in the system, CVWD only considers this fire flow analysis valid for six months from date of modelling/analysis. Should you have any questions or need additional information, please contact me at (760) 398-2661, ext. 2221. Completed By: , r.I Date: 1 6/16/2015 Reviewed By: Date: I �nf- 17, 2015 ZIPage1 of 1 ENG DS-016 (6/1/15) 1 FIRE SPRINKLER SYSTEMS INC. FIRE SPRINKLER SYSTEMS 705 E. HARRISON CORONA, CA 92879 800-915-3473 Job Name MONTERA Building PLAN 2 Location 55-119 AUTUMN VALLEY COURT System CALC AREA 1 Contract 31335 Data File PI-2 CA1.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 FIRE SPRINKLER SYSTEMS Page 1 MONTERA Date 9/15/15 HYDRAULIC DESIGN INFORMATION SHEET Name - MONTERA Date - 9/15/15 Location - 55-119 AUTUMN VALLEY COURT Building - PLAN 2 System No. - CALC AREA 1 Contractor - WOODBRIDGE PACIFIC Contract No. - 31335 Calculated By - EC Drawing No. - 31335 Construction: (X) Combustible ( ) Non -Combustible Ceiling Height 10 OCCUPANCY - RESIDENTIAL S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: (X)1 ( )2 ( )4 ( ) S ( ) Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 20 Gpm System Type Listed Pres. at Start Point - 16.7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 20 x 20 ( ) Deluge ( ) PreAction E Domestic Flow Added - 5 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make REALIABLE Model RFC49 I Elevation at Highest Outlet - Feet Size 7/16" K-Factor 4.9 G Note: Temperature Rating 165 N Calculation Gpm Required Psi Required At Test Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - Q Psi Elev. E Static (Psi) - 79.41 Elev. R Residual (Psi) - 77.69 Other Well Flow (Gpm) - 2500 Proof Flow Gpm S Elevation - 0 P Location: 10* TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C FIRE SPRINKLER SYSTEMS MONTERA Page 2 Date 9/15/15 City Water Supply: C1 - Static Pressure : 79.41 C2 - Residual Pressure: 77.69 C2 - Residual Flow : 2500 Demand: D1 - Elevation 5.630 D2 - System Flow 20.024 D2 - System Pressure 50.584 Hose ( Demand) 5 D3 - System Demand 25.024 Safety Margin 28.826 150 140 130 p 120 R 110 E 100 S 90 C1 S 80 C2 U 70 R 60 D2 E 50 40 D3 30 20 10 300 600 900 1200 1500 1800 2100 2400 2700 FLOW (NA1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary FIRE SPRINKLER SYSTEMS MONTERA Page 3 Date 9/15/15 Fitting Legend Abbrev. Name '/z % 1 1'/, 1'/z 2 2%z 3 3'/z 4 5 6 8 10 12 14 16 18 20 24 Ctr * Copper Cplg/Tee-Run 0.5 0.5 0.5 1 1 1 1.5 1.5 2 2 2.5 3 0 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 0 0 0 0 0 0 0 G NFPA 13 Gate Valve 0.001 0-001 0.001 0.001 0.001 1 1 1 1 2 2 14 3 18 22 27 35 40 45 50 61 Pel * CPVC 90'EII Harvel-Spears 7 7 8 9 11 12 13 0 0 0 4 5 6 7 8 10 11 13 Ptb * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 Ptr ` CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 0 22 0 27 0 32 0 45 0 55 0 65 0 0 0 0 0 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 riaw oummary - Nrl"A ZUU/ FIRE SPRINKLER SYSTEMS Page 4 MONTERA Date 9/15/15 SUPPLYANALYS/S Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure STR 79.41 77.69 2500.0 79.41 25.02 50.584 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H.10 11.0 4.9 16.7 20.02 T.46 11.0 18.38 T.48 11.0 18.7 T.51 11.0 19.4 T.59 11.0 20.36 T.67 11.0 21.05 T.70 11.0 21.37 T.72 11.0 21.91 H.35 11.0 22.55 T.73 11.0 22.71 T.74 11.0 23.67 H.34 11.0 24.1 H.31 11.0 24.53 T.68 11.0 24.64 T.65 11.0 25.22 H.27 11.0 25.28 T.64 11.0 26.08 T.63 11.0 27.2 H.25 11.0 27.36 H.21 11.0 28.01 T.55 11.0 28.49 S.1 11.0 31.44 BOR 2.0 37.26 5.0 UG1 -2.0 39.65 MTR -2.0 44.15 STR -2.0 50.58 H.8 11.0 18.51 T.38 11.0 19.2 T.39 11.0 19.26 HA 11.0 19.9 T.42 11.0 20.02 T.44 11.0 20.46 T.45 11.0 20.91 H.5 11.0 21.41 T.43 11.0 22.11 T.41 11.0 22.74 T.40 11.0 22.8 T.47 11.0 23.37 T.49 11.0 23.56 H.15 11.0 24.7 T.50 11.0 25.08 H.17 11.0 25.9 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 rww ournmary - NI -FA LUU/ FIRE SPRINKLER SYSTEMS MONTERA Page 5 Date 9/15/15 NODE ANALYSIS (cont.) Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes T.53 11.0 26.15 T.57 11.0 26.66 T.56 11.0 27.54 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 renal ualculatlons - Hazen -Williams FIRE SPRINKLER SYSTEMS r� Page 6 MONTERA Date 9/15/15 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv **` "' Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn H.10 to T.46 T.46 to T.48 T.48 to T.51 T.51 to 1.VU to T.67 T.67 to T.70 T.70 to 1. / L to H.35 H.35 to T.73 T.73 to T.74 T.74 to H.34 H.34 to H.31 H.31 to T.68_ T.68 to T.65 T.65 to H.27_ H.27 to T.64 20.02 0.874 Ptb 3.0 5.000 16.700 150.0 0.0 3.000 0.0 20.02 0.2100 0.0 8.000 1.680 -10.46 0.874 Ptr 1.0 5.000 18.380 150.0 0.0 1.000 0.0 9.56 0.0533 0.0 6.000 0.320 0.0 0.874 Ptr 1.0 12.000 18.700 150.0 0.0 1.000 0.0 _ 9.56 0.0535 0.0 13.000 0.696 0.0 0.874 Ptr 1.0 17.000 19.396 150.0 0.0 1.000 0.0 _ 9.56 0.0534 0.0 18.000 0.962 0.0 0.874 Ptr 1.0 12.000 20.358 150.0 0.0 1.000 0.0 9.56 0.0535 0.0 13.000 0.696 0.0 0.874 Ptr 1.0 5.000 21.054 150.0 0.0 1.000 0.0 9.56 0.0533 0.0 6.000 0.320 0.0 0.874 Ptb 3.0 7.000 21.374 150.0 0.0 3.000 0.0 9.56 0.0535 0.0 10.000 0.535 0.0 0.874 Ptr 1.0 11.000 21.909 150.0 0.0 1.000 0.0 9.56 0.0535 0.0 12.000 0.642 0.0 0.874 0.0 3.000 22.551 150.0 0.0 0.0 0.0 9.56 0.0533 0.0 3.000 0.160 0.0 0.874 Ptr 1.0 17.000 22.711 150.0 0.0 1.000 0.0 9.56 0.0535 0.0 18.000 0.963 0.0 0.874 Pei 7.0 1.000 23.674 150.0 0.0 7.000 0.0 9.56 0.0535 0.0 8.000 0.428 0.0 0.874 Ptr 1.0 7.000 24.102 150.0 0.0 1.000 0.0 9.56 0.0535 0.0 8.000 0.428 0.0 0.874 Ptr 1.0 1.000 24.530 150.0 0.0 1.000 0.0 9.56 0.0535 0.0 2.000 0.107 0.0 0.874 Ptr 1.0 7.000 24.637 150.0 Ptb 3.0 4.000 0.0 9.56 0.0535 0.0 11.000 0.588 0.0 0.874 0.0 1.000 25.225 150.0 0.0 0.0 0.0 9.56 0.0530 0.0 1.000 0.053 0.0 0.874 Ptr 1.0 14.000 25.278 150.0 0.0 1.000 0.0 9.56 0.0535 0.0 15.000 0.803 K Factor = 4.90 Vel = 10.71 Vel = 5.11 Vel = 5.11 Vel = 5.11 Vel = 5.11 Vel = 5.11 Vel = 5.11 Vel = 5.11 Vel = 5.11 Vel = 5.11 Vel = 5.11 Vel = 5.11 Vel = 5.11 Vel = 5.11 Vel = 5.11 Vel = 5.11 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 ruiai k diwiations - riazen-wnllams FIRE SPRINKLER SYSTEMS Page 7 MONTERA Date 9/15/15 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn T.64 0.0 0.874 Pei 7.0 14.000 to 150.0 0.0 7.000 T.63 _ 9.56 0.0535 0.0 21.000 T.63 0.0 0.874 0.0 3.000 to 150.0 0.0 0.0 H.25 9.56 0.0533 0.0 3.000 H.25 0.0 0.874 Ptr 1.0 11.000 to 150.0 0.0 1.000 H.21 9.56 0.0535 0.0 12.000 H.21 0.0 0.874 Ptb 3.0 5.000 to 150.0 Ptr 1.0 4.000 T.55 9.56 _ 0.0534 0.0 9.000 T.55 10.46 0.874 T 8.053 6.000 to 150.0 0.0 8.052 S.1 20.02 0.2099 0.0 14.052 S.1 0.0 1.101 E 3.825 9.000 to 150.0 2Ptr 2.0 19.212 BOR 20.02 0.0682 S 9.563 28.212 Eql 3.825 BOR 5.00 1.025 Ctr 0.5 4.000 to 150.0 0.0 0.500 UG1 25.02 0.1460 0.0 4.500 UG1 0.0 1.59 3E 17.062 70.000 to 150.0 0.0 17.062 MTR 25.02 0.0172 0.0 87.062 MTR 0.0 0.995 E 2.336 30.000 to 150.0 T 5.841 8.179 STIR 25.02 0.1687 G 0.001 38.179 0.0 25.02 T.46 10.46 0.874 to 150.0 H.8 10.46 0.0630 H.8 0.0 0.874 to 150.0 T.38 10.46 0.0632 T.38 0.0 0.874 to 150.0 T.39 10.46 0.0630 T.39 0.0 0.874 to 150.0 H.4 10.46 0.0632 H.4 0.0 0.874 to 150.0 T.42 10.46 0.0630 T.42 0.0 0.874 to 150.0 T.44 10.46 0.0631 Ptr 1.0 1.000 0.0 1.000 0.0 2.000 Pei 7.0 Ptr 1.0 0.0 0.0 0.0 0.0 Ptr 1.0 0.0 0.0 0.0 0.0 0.0_ Ptr 1.0 0.0 0.0 3.000 8.000 11.000 1.000 0.0 1.000 10.000 2.000 0.0 2.000 6.000 1.000 7.000 26.081 0.0 1.123 27.204 0.0 0.160 27.364 0.0 0.642 28.006 0.0 0.481 28.487 0.0 2.950 31.437 3.898 1.924 37.259 1.732 0.657 39.648 3.000 1.497 44.145 0.0 6.439 50.584 18.380 0.0 0.126 18.506 0.0 0.695 19.201 0.0 0.063 19.264 0.0 0.632 19.896 0.0 0.126 20.022 0.0 0.442 Vel = 5.11 Vel = 5.11 Vel = 5.11 Vel = 5.11 Vel = 10.71 Vel = 6.75 Qa=5 Vel = 9.73 * * Fixed Loss = 3 Vel = 4.04 Vel = 10.32 K Factor = 3.52 Vel = 5.59 Vel = 5.59 Vel = 5.59 Vel = 5.59 Vel = 5.59 Vel = 5.59 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 rural ualculatlons - Hazen -Willis FIRE SPRINKLER SYSTEMS Page 8 MONTERA Date 9/15/15 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn T.44 to T.45 T.45 to H.5 H.5 to _T.43 T.43 to T.41_ T.41 to T.40 T.40 to T.47 T.47 to T.49 T.49 to H.15 H.15 to T.50 T.50 to to T.53 T.53 to T.57_ T.57 to T.56 T.56 to 0.0 0.874 150.0 10.46 0.0631 0.0 0.874 150.0 10.46 0.0632 0.0 0.874 150.0 10.46 0.0632 0.0 0.874 150.0 10.46 0.0631 0.0 0.874 150.0 10.46 0.0640 0.0 0.874 150.0 10.46 0.0631 0.0 0.874 150.0 10.46 0.0633 0.0 0.874 150.0 10.46 0.0632 0.0 0.874 150.0 10.46 0.0632 0.0 0.874 150.0 10.46 0.0632 0.0 0.874 150.0 10.46 0.0632 0.0 0.874 150.0 10.46 0.0631 0.0 0.874 150.0 10.46 0.0632 0.0 0.874 150.0 10.46 0.0631 0.0 10.46 Ptr 1.0 0.0 0.0 Ptr 1.0 0.0 0.0 Ptr 1.0 0.0 0.0 Ptr 1.0 0.0 0.0 0.0 0.0 0.0 Ptb 3.0 0.0 0.0 0.0 0.0 0.0 Pel 7.0 0.0 0.0 Ptr 1.0 0.0 0.0 Ptb 3.0 Ptr 1.0 0.0 Ptr 1.0 0.0 0.0 Ptb 3.0 0.0 0.0 Ptr 1.0 0.0 0.0 Ptr 1.0 0.0 0.0 6.000 1.000 7.000 7.000 1.000 8.000 10.000 1.000 11.000 9.000 1.000 10.000 1.000 0.0 1.000 6.000 3.000 9.000 3.000 0.0 3.000 11.000 7.000 18.000 5.000 1.000 6.000 9.000 4.000 13.000 3.000 1.000 4.000 5.000 3.000 8.000 13.000 1.000 14.000 14.000 1.000 15.000 20.464 0.0 0.442 20.906 0.0 0.506 21.412 0.0 0.695 22.107 0.0 0.631 22.738 0.0 0.064 22.802 0.0 0.568 23.370 0.0 0.190 23.560 0.0 1.137 24.697 0.0 0.379 25.076 0.0 0.821 25.897 0.0 0.253 26.150 0.0 0.505 26.655 0.0 0.885 27.540 0.0 0.947 28.487 Vel = 5.59 Vel = 5.59 Vel = 5.59 Vel = 5.59 Vel = 5.59 Vel = 5.59 Vel = 5.59 Vel = 5.59 Vel = 5.59 Vel = 5.59 Vel = 5.59 Vel = 5.59 Vel = 5.59 Vel = 5.59 K Factor = 1.96 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 FSS FIRESPRINKLER SYSTENSINCO FIRE SPRINKLER SYSTEMS 705 E. HARRISON CORONA, CA 92879 800-915-3473 Job Name MONTERA Building PLAN 2 Location 55-119 AUTUMN VALLEY COURT System CALC AREA 2 Contract 31335 Data File PI-2 CA2.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 FIRE SPRINKLER SYSTEMS Page 1 MONTERA Date 9/15/15 HYDRAULIC DESIGN INFORMATION SHEET Name - MONTERRA Location - 55-119 AUTUMN VALLEY COURT Building - PLAN 2 Contractor - WOODBRIDGE PACIFIC Calculated By - EC Construction: (X) Combustible ( ) OCCUPANCY - RESIDENTIAL Date - 9/15/15 System No. - CALC AREA 2 Contract No. - 31335 Drawing No. - 31335 Non -Combustible Ceiling Height 10 S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( ) S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - 5 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make REALIABLE Model RFC49 I Elevation at Highest Outlet - Feet Size 7/16" K-Factor 4.9 G Note: Temperature Rating 165 N Calculation Gpm Required Psi Required At Test Summary C-Factor Used; Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - Q Psi Elev. E Static (Psi) - 79.41 Elev. R Residual (Psi) - 77.69 Other Well Flow (Gpm) - 2500 Proof Flow Gpm S Elevation - 0 P Location: 10% TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C FIRE SPRINKLER SYSTEMS MONTERA Page 2 Date 9/15/15 City Water Supply: C1 - Static Pressure : 79.41 C2 - Residual Pressure: 77.69 C2 - Residual Flow : 2500 Demand: D1 - Elevation 5.630 D2 - System Flow : 26.427 D2 - System Pressure 54.024 Hose ( Demand ) 5 D3 - System Demand : 31.427 Safety Margin : 25.385 150 140 130 P 120 R 110 E 100 S 90 C1 S 80 C2 U 70 v R 60 E 50 D3 40 30 20 10 300 600 900 1200 1500 1800 2100 2400 2700 FLOW (N ^ 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary FIRE SPRINKLER SYSTEMS MONTERA Page 3 Date 9/15/15 Fitting Legend Abbrev, Name '/Z 'i 1 1'. 1'/2 2 2'/: 3 3'.,;• 4 5 6 8 10 12 14 16 18 20 24 Ctr * Copper Cplg/Tee-Run 0.5 0.5 0.5 1 1 1 1.5 1.5 2 2 2.5 3 0 0 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 0 0 0 0 0 0 G NFPA 13 Gate Valve 0.001 0.001 0.001 0.001 0,001 1 1 1 1 2 12 2 14 18 22 27 35 40 45 50 61 Pel * CPVC 90'EII Harvel-Spears 7 7 8 9 11 12 13 0 0 3 4 5 6 7 8 10 11 13 Ptb * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 Ptr * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 0 27 0 32 0 45 0 0 0 0 0 0 0 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 55 65 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 rluw ounuiidiy - IVr-r-m zuut FIRE SPRINKLER SYSTEMS Page 4 MONTERA Date 9/15/15 SUPPLY ANAL YS/S Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure STR 79.41 77.69 2500.0 79.409 31.43 54.024 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H.36 11.0 4.9 7.04 13.0 T.71 11.0 7.89 T.72 11.0 8.65 H.35 11.0 10.16 T.73 11.0 10.54 T.74 11.0 12.81 H.34 11.0 13.81 H.31 11.0 14.82 T.68 11.0 15.08 T.65 11.0 16.46 H.27 11.0 16.59 T.64 11.0 18.48 T.63 11.0 21.13 H.25 11.0 21.51 H.21 11.0 23.02 T.55 11.0 24.15 S.1 11.0 29.08 BOR 2.0 36.2 5.0 UG1 -2.0 38.93 MTR -2.0 44.21 STR -2.0 54.02 H.33 11.0 4.9 7.51 13.43 T.70 11.0 8.61 T.67 11.0 9.04 T.59 11.0 9.98 T.51 11.0 11.27 T.48 11.0 12.21 T.46 11.0 12.64 H.8 11.0 12.78 T.38 11.0 13.58 T.39 11.0 13.65 HA 11.0 14.37 T.42 11.0 14.51 T.44 11.0 15.01 T.45 11.0 15.52 H.5 11.0 16.09 T.43 11.0 16.89 T.41 11.0 17.61 T.40 11.0 17.68 T.47 11.0 18.33 T.49 11.0 18.54 H.15 11.0 19.84 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 rww summary - NI-I•'A 1UU/ FIRE SPRINKLER SYSTEMS MONTERA Page 5 Date 9/15/15 NODE ANALYSIS (cont.) Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes T.50 11.0 20.27 H.17 11.0 21.2 T.53 11.0 21.49 T.57 11.0 22.07 T.56 11.0 23.07 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 rinal ualculatlons - Hazen -Williams FIRE SPRINKLER SYSTEMS Page 6 MONTERA Date 9/15/15 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ""`°' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn H.36 to T.71 T.71 to T.72 T.72 to H.35 H.35 to T.73_ T.73 to T.74 T.74 to H.34 H.34 to H.31 H.31 to to •vv T.65 T.65 to H.27 H.27 to T.64 T.64 to T.63 T.63 to H.25 H.25 to H.21 H.21 to T.55 T.55 to S.1 13.00 0.874 150.0 13.0 0.0944 0.0 0.874 150.0 13.0 0.0944 2.20 0.874 150.0 15.2 0.1261 0.0 0.874 150.0 15.2 0.1260 0.0 0.874 150.0 15.2 0.1261 0.0 0.874 150.0 15.2 0.1261 0.0 0.874 150.0 15.2 0.1261 0.0 0.874 150.0 15.2 0.1260 0.0 0.874 150.0 15.2 0.1261 0.0 0.874 150.0 15.2 0.1260 0.0 0.874 150.0 15.2 0.1261 0.0 0.874 150.0 15.2 0.1261 0.0 0.874 150.0 15.2 0.1260 0.0 0.874 150.0 15.2 0.1262 0.0 0.874 150.0 15.2 0.1260 11.23 0.874 150.0 26.43 0.3508 Pel 7.0 0.0 0.0 0.0 0.0 0.0 Ptr 1.0 0.0 0.0 0.0 0.0 0.0 Ptr 1.0 0.0 0.0 Pel 7.0 0.0 0.0_ Ptr 1.0 0.0 0.0 Ptr 1.0 0.0 0.0 Ptr 1.0 Ptb 3.0 Ptr 1.0 0.0 0.0 Pel 7.0 0.0 0.0 0.0 0.0 0.0 Ptr 1.0 0.0 0.0 Ptb 3.0 Ptr 1.0 ai T 8.053 0.0 0.0 2.000 7.040 7.000 0.0 9.000 0.850 8.000 7.890 0.0 0.0 8.000 0.755 11.000 8.645 1.000 0.0 12.000 1.513 3.000 0.0 3.000 17.000 1.000 18.000 1.000 7.000 8.000 7.000 1.000 8.000 1.000 1.000 2.000 7.000 4.000 11.000 1.000 0.0 1.000 14.000 1.000 15.000 14.000 7.000 21.000 3.000 0.0 3.000 11.000 1.000 12.000 5.000 4.000 9.000 6.000 8.052 14.052 10.158 0.0 0.378 10.536 0.0 2.270 12.806 0.0 1.009 13.815 0.0 1.009 14.824 0.0 0.252 15.076 0.0 1.387 16.463 0.0 0.126 16.589 0.0 1.891 18.480 0.0 2.648 21.128 0.0 0.378 21.506 0.0 _1.514 23.020 0.0 1.134 24.154 0.0 4.929 K Factor = 4.90 Vel = 6.95 Vel = 6.95 Vel = 8.13 Vel = 8.13 Vel = 8.13 Vel = 8.13 Vel = 8.13 Vel = 8.13 Vel = 8.13 Vel = 8.13 Vel = 8.13 Vel = 8.13 Vel = 8.13 Vel = 8.13 Vel = 14.13 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams FIRE SPRINKLER SYSTEMS 1 Page 7 MONTERA Date 9/15/15 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn S.1 0.0 1.101 to 150.0 BOR 26.43 0.1139 BOR 5.00 1.025 to 150.0 UG1 31.43 0.2227 UG1 0.0 1.59 to 150.0 MTR 31.43 0.0262 MTR 0.0 0.995 to 150.0 STIR 31.43 0.2570 0.0 31.43 H.33 13.43 0.874 to 150.0 T.70 13.43 0.1002 T.70 -2.20 0.874 to 150.0 T.67 11.23 0.0720 T.67 0.0 0.874 to 150.0 T.59 11.23 0.0719 T.59 0.0 0.874 to 150.0 T.51 11.23 0.0720 T.51 0.0 0.874 to 150.0 T.48 11.23 0.0719 T.48 0.0 0.874 to 150.0 T.46 11.23 0.0720 T.46 0.0 0.874 to 150.0 H.8 11.23 0.0720 H.8 0.0 0.874 to 150.0 T.38 11.23 0.0720 T.38 0.0 0.874 to 150.0 T.39 11.23 0.0710 T.39 0.0 0.874 to 150.0 H.4 _ 11.23 0.0720 HA 0.0 0.874 to 150.0 T.42 11.23 0.0720 E 3.825 9.000 2Ptr 2.0 19.212 S 9.563 28.212 Eql 3.825 Ctr 0.5 4.000 0.0 0.500 0.0 4.500 3E 17.062 70.000 0.0 17.062 0.0 87.062 E 2.336 30.000 T 5.841 8 17Q Ptb 3.0 nn Ptr 1.0 0.0 0.0 Ptr 1.0 0.0 0.0 Ptr 1.0 0.0 0.0 Ptr 1.0 0.0 0.0 Ptr 1.0 0.0 0.0 Ptr 1.0 0.0 0.0 Pei 7.0 Ptr 1.0 0.0 0.0 nn Ptr 1.0 0.0 0.0 0.0 0.0 0.0 29.083 3.898 3.214 36.195 1 732 3.000 2.282 44.211 0.0 9.813 54.024 3.000 0.0 11.000 1.102 5.000 8.610 1.000 0.0 6.000 0.432 12.000 9.042 1.000 0.0 13.000 0.935 17.000 9.977 1.000 0.0 18.000 1.296 12.000 11.273 1.000 0.0 13.000 0.935 5.000 12.208 1.000 0.0 6.000 0.432 1.000 12.640 1.000 0.0 2.000 0.144 3.000 12.784 8.000 0.0 11.000 0.792 1.000 13.576 n_n n n 1.000 0.0 10.000 0.720 2.000 14.367 0.0 0.0 2.000 0.144 Val = R Q1 Vel = 12.22 * * Fixed Loss = 3 Vel = 5.08 Vel = 12.97 K Factor = 4.28 K Factor = 4.90 Vel = 7.18 Vel = 6.01 Vel = 6.01 Vel = 6.01 Vel = 6.01 Vel = 6.01 Vel = 6.01 Vel = 6.01 Vel = 6.01 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 rmai uaiwiations - riazen-mmams FIRE SPRINKLER SYSTEMS Page 8 MONTERA Date 9/15/15 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv "' "*' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn to to to H.5 H.5 to T.43 T.43 to T.41 T.41 to T.40 T.40 to T.47 T.47 to T.49 T.49 to H.15 H.15 to T.50 T.50 to H.17 H.17 to T.53_ T.53 to to T.56 T.56 to T.55 T.70 to T.72 0.0 0.874 150.0 11.23 0.0720 0.0 0.874 150.0 11.23 0.0719 0.0 0.874 150.0 11.23 0.0720 0.0 0.874 150.0 11.23 0.0720 0.0 0.874 150.0 11.23 0.0720 0.0 0.874 150.0 11.23 0.0720 0.0 0.874 150.0 11.23 0.0719 0.0 0.874 150.0 11.23 0.0720 0.0 0.874 150.0 11.23 0.0719 0.0 0.874 150.0 11.23 0.0720 0.0 0.874 150.0 11.23 0.0720 0.0 0.874 150.0 11.23 0.0720 0.0 0.874 150.0 11.23 0.0719 Ptr 1.0 0.0 0.0 Ptr 1.0 0.0 0.0 Ptr 1.0 0.0 0.0 Ptr 1.0 0.0 0.0 Ptr 1.0 0.0 0.0 0.0 0.0 0.0 Ptb 3.0 0.0 0.0 0.0 0.0 0.0 Pel 7.0 0.0 0.0 Ptr 1.0 0.0 0.0 Ptb 3.0 Ptr 1.0 0.0 Ptr 1.0 0.0 0.0 Ptb 3.0 0.0 0.0 6.000 1.000 7.000 6.000 1.000 7.000 7.000 1.000 8.000 10.000 1.000 11.000 9.000 1.000 10.000 1.000 0.0 1.000 6.000 3.000 9.000 3.000 0.0 3.000 11.000 7.000 18.000 5.000 1.000 6.000 9.000 4.000 13.000 3.000 1.000 4.000 5.000 3.000 8.000 14.511 0.0 0.504 15.015 0.0 0.503 15.518 0.0 0.576 16.094 0.0 0.792 16.886 0.0 0.720 17.606 0.0 0.072 Vel = 6.01 Vel = 6.01 Vel = 6.01 Vel = 6.01 Vel = 6.01 Vel = 6.01 17.678 0.0 0.647 Vel = 6.01 18.325 0.0 0.216 Vel = 6.01_ 18.541 0.0 1.295 Vel = 6.01 19.836 0.0 0.432 Vel = 6.01 20.268 0.0 _0.936 21.204 0.0 0.288 21.492 0.0 0.575 Vel = 6.01 Vel = 6.01 Vel = 6.01 0.0 0.874 Ptr 1.0 13.000 22.067 150.0 0.0 1.000 0.0 11.23 0.0720 0.0 14.000 1.008 Vel = 6.01 0.0 0.874 Ptr 1.0 14.000 23.075 _ 150.0 0.0 1.000 0.0 11.23 0.0719 0.0 15.000 1.079 Vel = 6.01 0.0 11.23 24.154 K Factor = 2.28 2.20 0.874 Ptb 3.0 7.000 8.610 150.0 0.0 3.000 0.0 2.2 0.0035 0.0 10.000 0.035 Vel = 1.18 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 renal uaiculations - Hazen-wimapI FIRE SPRINKLER SYSTEMS Page 9 MONTERA Date 9/15/15 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv *""'*** Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 — 2.20 8.645 K Factor = 0.75 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 r—. ,I Riverside County Fire Department Fire Protection Planning Section Riverside Dir": 2300 Market St., Ste. 150, Rwr5idr, CA 9250f Ph, (051] 955.4777 Fax (951] 955-�89b Murliefa giflce; 394$3 Los Alamos Rd., Ste A, Murrleie, Cq 925&3 Ph. {951j fi00$180 Fax (95f] 600.5184 Palm DesertOffma= 77-933 Las M"Uihas Rd., * 201Palm Desert, CA 92211 •4131 Ph. {750] 863-888617601 863-7072 Date: 4"� To: LA QUINTA B&S Fax: Tract/Parcel Map #: Permit/Lot #: Job Site Address: XX xx Fire Department Clearance/Release MONTERRA #35 LAQ-15-RS-144 55119 AUTUMN VALLEY CT LA QUINTA Final For Recordation - RESIDENTIAL SPRINKLER SYSTEM Release For Building Permit(s) Shell Final Only (No Tenant) Final For Occupancy Building Plan Check Fees Paid Building Plan Check Fees Not Paid Other Fees Fees Not Required If you should have any questions, please contact the appropriate Riverside County Fire Protection Planning office for further assistance. —Z8K-'- A��— Authorizing Signature For Release KOHL HETRICK rrmt Name Form C — Revised 6/19/2014 Hetrick, Kohl@CALFIRE Subject: 2. LAQ-I5-RS-144 - MONTERRA - RES SPK FINAL Location: 55119 AUTUMN VALLEY COURT, LOT 35, LA QUINTA Start: Thu 1/21/2016 8:00 AM End: Thu 1/21/2016 9:00 AM Recurrence: (none) Organizer: Hetrick, Kohl@CALFIRE Rep. Name: Carlos Phone#: 800-915-3473 Cell#: Co. Name: 951-847-2908 Fire Sprinkler Systems, Inc. _ CrossSt: HYDRANT SYSTEM PASS FAIL FIRE ALARM PASS FAIL Thrust block re -pour Rough -wire inspection Underground rough Function test Underground hydro Duct detectors/velocity Flush 24 hr. battery test Final Sprinkler monitoring SPRINKLER U.G. Final Thrust block pre -pour SPECIAL SUPPRESSION Underground rough Door fan test Underground hydro Abort test Flush Mechanical shutdown Final Detector test FIRE SPRINKLER Deluge/pre-action Weld inspection Final Overhead rough eiping UST/AST TANK Overhead hydro Installation UG flush / OK to connect Removal Main drain/inspect. Test Emergency shut off High pile storage Primary piping In-racksprinklers Secondary piping Hose racks Dispensers & shear valves X Final Final KITCHEN HOOD EXTINGUISHING MISC. INSPECTION Detections stem Sprav booths Function Test Hood/duct extinguishing Gas/Electrical shut-off High pile rack storage Nozzle model/placement H.P. vents/access/corridors Fire alarm connection Tract access/hydrant verification Final Other: SPRAY BOOTHS KNOX SYSTEM Installation Building Knox box Air flow test Gate access Knox box/ adlock Mechanical interlock BUILDING INSPECTIONS Extinguishing system T/I final Fire alarm connection Shell final Final Final for occupancy Start Time: Finish Time: Start Time: I Finish Time: 1 Cervantes, Thomas@CALFIRE Subject: LAQ-I5-RS-144 - MONTERRA/ LOT 35 - RES OH ROUGH/ HYDRO Location: 55119 AUTUMN VALLEY COURT, LOT 35, LA QUINTA Start: Fri 10/16/2015 2:00 PM End: Fri 10/16/2015 3:00 PM Recurrence: (none) Organizer: Cervantes, Thomas@CALFIRE Rep. Name: Carlos Phone#: Co. Name: Cell#: 951-847-2908 FSS CrossSt: HYDRANT SYSTEM PASS FAIL FIRE ALARM PASS FAIL Thrust block pre- our Underground.rou h Rough -wire inspection Function test Under round hydro Duct detectors/veloci Flush 24 hr. battery test Final Sprinkler monitoring SPRINKLER U.G. Final Thrust block pre -pour SPECIAL SUPPRESSION Underground rough Door fan test Underground hydro Abort test Flush Mechanical shutdown Final Detector test FIRE SPRINKLER Deluge/pre-action Weld inspection Final X Overhead rough piping UST/AST TANK X Overhead hydro a' Installation UG flush / OK to connect I Removal Main drain/Inspect. Test Emergency shut off High pile storage Primaty pi in In-racksprinklers Secondary piping Hose racks Dispensers & shear valves Final Final KITCHEN HOOD EXTINGUISHING MISC. INSPECTION Detections stem I Sprav booths Function Test Hood/duct extinguishing Gas/Electrical shut-off High Dile rack stora e Nozzle model/placement H.P. vents/access/corridors Fire alarm connection Tract access/hydrant verification Final Other: SPRAY BOOTHS KNOX SYSTEM Installation Building Knox box Air flow test Gate access Knox box/padlock Mechanical interlock BUILDING INSPECTIONS Extinguishing system T/I final Fire alarm connection Shell final Final Final for occupancy Start Time: Finish Time: Start Time: Finish Time: 1 I Riverside County Fire Department Riverside Office: 2300 Market Street, Ste. 150 Riverside, CA 92501 Phone: (951) 955-4777 - Fax: (951) 955-4886 Fire Protection Planning Y Palm Desert Office: 77-933 Las Montanas Rd., Ste 201 Palm Desert CA 92211 Phone: (760) 863-8886 - Fax: (760) 863-7072 PLAN REVIEW FORM El New ❑ Re -Submittal # ❑ As-builts Permit No. LAQ_ 5_ R5 - ly y Project Information (Please Print) # PkE5201 5 - 009a.- Project Name: MONTERRA / TRACT 32742 / PLAN 2 Address: LOT 35 / 55-119 AUTUMN VALLEY COURT city & zip: LA QUINTA, CA Contact Information CONTACT PERSON: JAMIE BISHIP Mailing Address: City & Zip Office Use Only Riverside County Fire Office of the Fire Marshal 3EP 16 201! Received By. L,. I have read and understand that Fire Dept. fees are Deposit used Fees and there may be additional money due Prior to or after Project final. Sign: Print: JAMIE BISHIP Billing Information ❑ Same as Contact Info BILL TO: FIRE SPRINKLER SYSTEMS, INC. 705 E. HARRISON ST., SUITE 200 Mailing Address: 705 E. Harrison St. Suite 200 CORONA, CA 92879 Phone No.: 1-800-915-3473 Fax: Email: jamieb@fireinc.net City & zip Corona, CA 92879 Phone No.: 1-800-915-3473 Fax: Email: jamieb@fireinc.net The person listed on "Billing Information" will receive ALL billing, correspondence and refunds for any work billed to this permit. Any changes in billing information must be matte in writing to our office, Plan Review Type Check a ro riate items ❑ Commercial ❑ Industrial 10 Residential ❑ Special Event ❑ Other ❑ Building ❑ Building Tenant Improvement ❑ High Fire Area ❑ Underground Water O Sprinkler System ❑ TI Sprinkler System ❑ Sprinkler Monitoring Q Fire Alarm System ❑ Hood & Duct Suppression System ❑ Other Suppression System ❑ Spray Booth ❑ Cell Site ❑ High Pile/Racks 0 Other: SEE MASTER PERMIT#: MASTER PLAN TYPE 2 Storage Tank Submittals: ❑ Dispensers Only ❑ Above Ground ❑ Underground Fee Paid: S 6 /11 Date Paid: /-QP/ , - Check#: ZZa 973 Reviewed by: Called for Pick -Up PC Review Date: Date: 1 / 0 Approved CI Denied Picked -Up Received By: Plans Stamped: Mes ONO Date, / By. —1-A Letter Attached: PYes ONO ✓ceipt#(OCRJ�-off ,lob Card Included: CIF" Yes ONO Shipped By / Method Form 1 —Revised 1012T50 00 Visit us at www.rvcfire.org