LAQ-16-RS-033 PGA West The Estates Plan 3ADDITIONAL SITES
CHRONOLOGY
CONTACTS
NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL
APPLICANT CALIFORNIA WEST CONSTRUCTION I 5927 PRIESTLY DRIVE
STE 110
CARLSBAD CA 92008 LBELLOSO@CALWESTC
OMMUNITIES.COM
CONTRACTOR CALIFORNIA WEST CONSTRUCTION I 5927 PRIESTLY DRIVE
STE 110
CARLSBAD CA 92008 LBELLOSO@CALWESTC
OMMUNITIES.COM
OWNER RREF II CWC LAQ LLC 5927 PRIESTLY DR STE
110
CARLSBAD CA 92008
CONDITIONS
Description: THE SIGNATURE PH 1 ESTATES LOT 74 TM 36537
Type: BUILDING RESIDENTIAL Subtype: DWELLING - SINGLE
FAMILY DETACHED
Status: FINALED Applied: 4/27/2015 MFA
Parcel No: 775220021 Site Address: 80444 CHAMPIONS WY LA QUINTA,CA 92253 Approved: 5/7/2015 MFA
Subdivision: Block: Lot: 74 Issued: 5/7/2015 MFA
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 3/9/2017 AOR
Valuation: $258,038.20 Occupancy Type: Construction Type: Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: 2,921 SF DWELLING 191 SF PORCH 257 SF OUTDOOR LIVING. PLAN TYPE 3A, LOT 74 [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES
NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2013 CALIFORNIA BUILDING CODES.
PERMIT EXTENSION GRANTED UNTIL MAY 2, 2016 TO PASS INSPECTION
RIVERSIDE COUNTY FIRE PERMIT #LAQ-16-RS-033. SEE FIRE FOLDER.
FINANCIAL INFORMATION
Printed: Wednesday, February 28, 2024 4:03:11 PM 1 of 8
Permit Details
City of La Quinta
PERMIT NUMBER
BRES2015-0162
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
ART IN PUBLIC PLACES -
RESIDENTIAL 270-0000-43201 0 $145.09 $145.09 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
Total Paid for ART IN PUBLIC PLACES - AIPP: $145.09 $145.09
BSAS SB1473 FEE 101-0000-20306 0 $11.00 $11.00 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
Total Paid for BUILDING STANDARDS ADMINISTRATION
BSA: $11.00 $11.00
DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $942.00 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
DIF - COMMUNITY
CENTERS 254-0000-43200 0 $129.00 $129.00 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $433.00 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
DIF - LIBRARIES 253-0000-43200 0 $344.00 $344.00 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
DIF - PARK
MAINTENANCE 256-0000-43200 0 $40.00 $40.00 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $2,048.00 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
DIF - STREET
MAINTENANCE 255-0000-43200 0 $116.00 $116.00 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 $2,842.00 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 $6,894.00
TEMP POWER SERVICE 101-0000-42403 0 $24.17 $24.17 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
TEMP POWER SERVICE
PC 101-0000-42403 0 $16.92 $16.92 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
Total Paid for ELECTRICAL: $41.09 $41.09
RESIDENTIAL, EA
ADDITION 1,000SF 101-0000-42403 0 $36.99 $36.99 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
RESIDENTIAL, EA
ADDITION 1,000SF, PC 101-0000-42600 0 $15.24 $15.24 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
Printed: Wednesday, February 28, 2024 4:03:11 PM 2 of 8
Permit Details
City of La Quinta
PERMIT NUMBER
BRES2015-0162
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
RESIDENTIAL, FIRST
1,000SF 101-0000-42403 0 $145.03 $145.03 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
RESIDENTIAL, FIRST
1,000SF, PC 101-0000-42600 0 $47.86 $47.86 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $245.12 $245.12
RESIDENTIAL PRECISE
GRADING - TRACT
HOME
101-0000-42408 0 $133.43 $133.43 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
Total Paid for GRADING: $133.43 $133.43
CONDENSER/COMPRES
SOR 101-0000-42402 0 $36.26 $36.26 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
CONDENSER/COMPRES
SOR PC 101-0000-42600 0 $24.17 $24.17 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
EXHAUST HOOD 101-0000-42402 0 $12.09 $12.09 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
EXHAUST HOOD PC 101-0000-42600 0 $4.83 $4.83 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
FURNACE 101-0000-42402 0 $36.26 $36.26 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
FURNACE PC 101-0000-42600 0 $24.17 $24.17 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
VENT FAN 101-0000-42402 0 $72.54 $72.54 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
VENT FAN PC 101-0000-42600 0 $28.98 $28.98 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
Total Paid for MECHANICAL: $239.30 $239.30
MULTI-SPECIES
RESIDENTIAL 0-8 UNITS 101-0000-20310 0 $1,292.00 $1,292.00 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
Total Paid for MULTI-SPECIES RESIDENTIAL: $1,292.00 $1,292.00
NEW CONSTRUCTION
PERMIT 101-0000-42400 0 $614.61 $614.61 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
Total Paid for NEW CONSTRUCTION PERMIT: $614.61 $614.61
Printed: Wednesday, February 28, 2024 4:03:11 PM 3 of 8
Permit Details
City of La Quinta
PERMIT NUMBER
BRES2015-0162
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
NEW CONSTRUCTION
PLAN CHECK 101-0000-42600 0 $1,308.28 $1,308.28 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,308.28 $1,308.28
BACKFLOW DEVICE 101-0000-42401 0 $12.09 $12.09 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
BACKFLOW DEVICE PC 101-0000-42600 0 $4.83 $4.83 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
BUILDING SEWER 101-0000-42401 0 $12.09 $12.09 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
BUILDING SEWER PC 101-0000-42600 0 $12.09 $12.09 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
FIXTURE/TRAP 101-0000-42401 0 $205.53 $205.53 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
FIXTURE/TRAP PC 101-0000-42600 0 $205.53 $205.53 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
GAS SYSTEM, 5+
OUTLETS 101-0000-42401 0 $36.26 $36.26 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
GAS SYSTEM, 5+
OUTLETS PC 101-0000-42600 0 $24.17 $24.17 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
WATER HEATER/VENT 101-0000-42401 0 $12.09 $12.09 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
WATER HEATER/VENT
PC 101-0000-42600 0 $7.25 $7.25 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
WATER SYSTEM
INST/ALT/REP 101-0000-42401 0 $12.09 $12.09 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
WATER SYSTEM
INST/ALT/REP PC 101-0000-42600 0 $12.09 $12.09 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
Total Paid for PLUMBING FEES: $556.11 $556.11
SMI - RESIDENTIAL 101-0000-20308 0 $33.55 $33.55 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $33.55 $33.55
SINGLE FAMILY
DETACHED 224-0000-20320 0 $1,837.44 $1,837.44 5/7/15 R5893 10885 CHECK RREF II CWC LAQ LLC MFA
Total Paid for TUMF - RESIDENTIAL: $1,837.44 $1,837.44
Printed: Wednesday, February 28, 2024 4:03:11 PM 4 of 8
Permit Details
City of La Quinta
PERMIT NUMBER
BRES2015-0162
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED
DATE
COMPLETED
DATE
RESULT REMARKS NOTES
SEWER CONNECTION JFU 3/30/2016 3/30/2016 NOT READY
UNDERGROUND PLBG JFU 3/30/2016 3/30/2016 NOT READY
WORK INCOMPLETE. LEAK WAS FOUND IN
THE A.M. AND SYSTEM WAS NOT YET FULLY
CHARGED.
SEWER CONNECTION JFU 3/31/2016 3/31/2016 APPROVED
UNDERGROUND PLBG JFU 3/31/2016 3/31/2016 APPROVED
FOOTINGS JFU 4/7/2016 4/7/2016 CANCELED
FOOTINGS AOR 4/8/2016 4/8/2016 DISAPPROVE
D
DEEPENED FOOTING REINFORCEMENT NOT
PER DETAILS, AT FOOTINGS DEEPENED
MORE THEN APPROVED PLAN STILL NEED
REINFORCEMENT PER DETAILING. WALKED
ONLY FRONT OF DWELLING, CORRECTIONS
REQUIRE REINSPECTION ONCE WORK IS
CORRECTED, CONTRACTOR TO VERIFY
REMAINING WORK IS IN COMPLIANCE WITH
APPROVED PLAN PRIOR TO REQUESTING
REINSPECTION.
SLAB AOR 4/8/2016 4/8/2016 NOT READY SEE FOOTING CORRECTIONS
FOOTINGS JFU 4/11/2016 4/11/2016 APPROVED
FLOOR NAIL JFU 7/8/2016 7/8/2016 APPROVED NO JOB CARD ON SITE.
ROOF NAIL JFU 7/19/2016 7/19/2016 APPROVED
OKAY TO WRAP JFU 8/10/2016 8/10/2016 APPROVED
FRAMING JFU 8/17/2016 8/17/2016 APPROVED
ROUGH ELEC JFU 8/17/2016 8/17/2016 APPROVED
ROUGH MECH JFU 8/17/2016 8/17/2016 APPROVED
TOTALS:$13,351.02 $13,351.02
Printed: Wednesday, February 28, 2024 4:03:11 PM 5 of 8
Permit Details
City of La Quinta
PERMIT NUMBER
BRES2015-0162
BOND INFORMATION
ROUGH PLBG JFU 8/17/2016 8/17/2016 APPROVED
SHOWER PAN JFU 8/17/2016 8/17/2016 APPROVED
INSULATION JFU 8/22/2016 8/22/2016 APPROVED
LATH AOR 8/26/2016 8/26/2016 APPROVED
DRYWALL NAIL JFU 8/30/2016 8/30/2016 APPROVED
GAS LINE/TEST JFU 9/16/2016 9/16/2016 APPROVED
DRIVEWAY APPROACH JPE 11/2/2016 11/2/2016 APPROVED
0815 to 0830Ok To Place concrete for drive
approach Weather - clear - breeze to 10mph
- temperature 65 to 85
TEMP USE OF PERM PWR JFU 11/15/2016 11/15/2016 APPROVED
JP- PUBLIC WORKS FINAL JPE 12/15/2016 12/15/2016 APPROVED
0800 to 0830Weather - cloudy - breeze to 4
mph - temperature 50 to 75Met with Jon
Celli at site - checked the yard drains and
they are clean and open - drain hole at base
of the side yard block wall - swales are
graded all trenches are backfilled - front yard
landscaped - backyard drain holes are cored
thru the curbs - site is clean and OK to Final
FINAL**JFU 3/9/2017 3/9/2017 APPROVED
HERS REGISTRATION NO: 216-N0184624A-
M2000002A-M20A
REGISTRATION DATE: 1/4/2017
HERS PROVIDER: CALCERTS, INC.
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED
DATE
STATUS REMARKS NOTES
FIRE KOHL
HETRICK
6/28/2016 7/18/2016 7/18/2016 APPROVED FIRE APPROVAL LETTER IN ATTACHMENTS
PARENT PROJECTS
Printed: Wednesday, February 28, 2024 4:03:11 PM 6 of 8
Permit Details
City of La Quinta
PERMIT NUMBER
BRES2015-0162
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 1/20/2016 BURT HANADA
ESTATES PHASE 2
EXTENSION
REQUEST.pdf
ESTATES PHASE 2
EXTENSION
REQUEST.pdf
1
DOC 1/20/2016 BURT HANADA Signature Phase 2
Permits Extension.docx
Signature Phase 2
Permits.docx 1
DOC 5/8/2015 CECILIA PATINO BRES2015-0162 ISSUED
PERMIT.pdf
BRES2015-0162 ISSUED
PERMIT.pdf 0
DOC 3/9/2017 JAKE FUSON CERTIFICATE OF
OCCUPANCY
BRES2015-0162 -
CERTIFICATE OF
OCCUPANCY.pdf
1
DOC 3/9/2017 JAKE FUSON FIRE DEPARTMENT
CLEARANCE
BRES2015-0162 - FIRE
DEPARTMENT
CLEARANCE.pdf
1
DOC 7/18/2016 KOHL HETRICK FIRE - RESIDENTIAL FIRE
SPRINKLER - APPROVED
LAQ-16-RS-033 - RFSPK
PC - APPROVED.docx 0
DOC 3/31/2016 RAMSES SEVILLA
2215 TM 36537-1 Form
Certs Lots 16 73-75 82-
83 3-28-16.pdf
2215 TM 36537-1 Form
Certs Lots 16 73-75 82-
83 3-28-16.pdf
1
IMAGE 12/15/2016 JIM PETERS
look east at backyard of
80444 Champions
Way.JPG
look east at backyard of
80444 Champions
Way.JPG
0
IMAGE 12/15/2016 JIM PETERS
look south at east side
yard of 80444
Champions Way.JPG
look south at east side
yard of 80444
Champions Way.JPG
0
IMAGE 12/15/2016 JIM PETERS permit at 80444
Champions.JPG
permit at 80444
Champions.JPG 0
IMAGE 11/2/2016 JIM PETERS drive approach at 80444
Champions Way.JPG
drive approach at 80444
Champions Way.JPG 0
IMAGE 12/15/2016 JIM PETERS front of 80444
Champions Way.JPG
front of 80444
Champions Way.JPG 0
Printed: Wednesday, February 28, 2024 4:03:11 PM 7 of 8
Permit Details
City of La Quinta
PERMIT NUMBER
BRES2015-0162
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
IMAGE 11/2/2016 JIM PETERS permit for 80444
Champions Way.JPG
permit for 80444
Champions Way.JPG 0
IMAGE 12/15/2016 JIM PETERS
west side yard look
north at 80444
Champions Way.JPG
west side yard look
north at 80444
Champions Way.JPG
0
Printed: Wednesday, February 28, 2024 4:03:11 PM 8 of 8
Permit Details
City of La Quinta
PERMIT NUMBER
BRES2015-0162
13DICRC 313. 3 GENERAL NOTES
1. AUTOMATIC FIRE SPRINKLER SYSTEM HAS BEEN DESIGNED TO BE INSTALLED IN
ACCORDANCE WITH NFPA 13D, 2013 EDITION AND THE REQUIREMENTS OF
PIVERSIDE COUNTY(PALM DESERT).
2. THIS SPRINKLER SYSTEM SHALL BE TESTED AND INSPECTED BOTH THE ROUGH AND
FINAL INSPECTION PRIOR TO OCCUPANCY BEING GRANTED. THE JURISDICTIONAL FIRE
PREVENTION OFFICE WILL BE NOTIFIED A MINIMUM OF TWO WORKING DAYS IN ADVANCE
OF THE REQUESTED INSPECTION.
3, THE INSTALLER SHALL PERFORM ALL REQUIRED ACCEPTANCE TESTS.
4. NOTCHING, DRILLING, OR OTHERWISE PENETRATING STRUCTURAL MEMBERS SHALL BE
IN ACCORDANCE WITH CALIFORNIA BUILDING CODE.
5. TYPE OF PLASTIC PIPE TO BE CPVC MANUFACTURED BY BLAZE MASTER U.L. LISTED.
6. ALL VALVES SHALL HAVE A PERMANENTLY AFFIXED SIGN INDICATING IT'S FUNCTION,
7, PIPE SHALL BE BUNG FROM STRUCTURAL MEMBER PER THE UNIFORM PLUMBING CODE.
PIPE CLAMPS AND SCREWS ARE MANUFACTURED BY AFCON MFG. ARE U.L. LISTED AND
ARE INSTALLED] ACCORDING TO THE HANGING REQUIREMENTS IN THEIR TECHNICAL
DATA (SEE DETAIL).
8. THE SPACING AND LOCATION OF SPRINKLERS SHALL CONFORM WITH THE
MANUFACTURES REQUIREMENTS AND THOSE CONTAINED IN NFPA 13D, 2013 EDITION.
9. IF REQUIRED BY A.H.J. THE ALARM INDICATING DEVICE SHALL BE LISTED FOR OUTSIDE
SERVICE AND AUDIBLE FROM THE STREET THAT THE HOUSE IS ADDRESSED ON.
10_ SMOKE DETECTORS TO BE INSTALLED BY OTHERS.
11. RESIDENTIAL CONCEALED PENDENT SPRINKLERS ARE U.L. LISTED AND MANUFACTURED
BY RELIABLE. INSTALLED AT 16 FT. MAXIMUM SPACING(SEE TECH, DATA).
12. PENDENT INTERMEDIATE TEMP. QUICK RESPONSE SPRINKLERS ARE U.L. LISTED AND
MANUFACTURED BY RELIABLE INSTALLED AT 16 FT. MAX. SPACING (SEE TECH. DATA).
13. PENDENT SPRINKLERS ARE AT LEAST 3 It. FROM OBSTRUCTIONS E.G. LIGHT FIXTURES,
CEILING FANS, ETC. OR IN ACCORDANCE WITH TABLE 8.2.5.4.2 AND SECTION 8.2.5.2.
SPRINKLER LOCATIONS FOR CONTINUOUS OBSTRUCTIONS ARE IN COMPLIANCE WITH
8.2.5.4.
14. SOFFITS AND CABINETS TO BE PROVIDED WITH SPRINKLER COVERAGE IN ACCORDANCE
WITH 8.2.5.6.
MATERIAL NOTES
1. ALL PIPE TO BE BLAZEMASTER CPVC PIPE AND CONCEALED,
2. HEADS IN RESIDENTIAL AREAS TO BE RELIABLE RFC49 4.91K MODELS AND SPACED AT
16' X 16'. UNLESS OTHERWISE STATED.
3. HEADS IN GARAGE AREA ARE RELIABLE F1 RES 49, AND SPACED AT 16' X 16'.
UNLESS OTHERWISE STATED.
4, RISER TO BE 1" BLAZEMASTER CPVC AND CONCEALED IN WALL WITH ACCESS
PANEL,
5. ALL PIPE SUPPORTS ARE TO BE PER NFPA #13D, 2013 ED. REQUIREMENTS. HANGERS
TO BE PLACED NO MORE THAN 6-0" Q.C.
6. ALL MATERIALS ARE TO BE UL LISTED. ALL WORK IS TO BE DONE IN ACCORDANCE
WITH NFPA STANDARDS.
SCOPE OF WORK
1. INSTALL NEW FIRE PROTECTION SYSTEM IN NEW HOME.
2. ALL PIPE TO BE NEW AND U.L. LISTED FOR USE IN FIRE PROTECTION SYSTEMS_
,. NO PENETRATIONS THROUGH RATED WALLS.
4. FITTING CLASS AND TYPE SHALL MEET OR EXCEED NFPA 13D (2013) AND COUNTY.
APPROVAL AND LISTED FOR USE IN FIRE PROTECTION.
I`, 1 Ceiling
B
(7t16trI1C1'16n
❑ I A
A ? (D - 8in) + 8
[A�(D-0.2m)+B]
where: ❑ 5 30in. (0.8 m)
FIGURE A.8. 2.5.7(a) Examnie of Shadow Areas (SSUISSP)-
Elevation View
FIGURE 8.2.5.4.3 Pvshlurling of Sprinkler to Avaid 8.2.5.7 Shadow Areas, Shadow areas shall be permitted in the
Obstruction Against Walls (Residential Upright and protection area of a sprinkler as long as the cumulative
Ioendent Spray Sprinklers}.
dry areas do not exceed 15 ff' (1.4ml) per sprinkler
_51ZE - 3/4" thru 2" pipe
M TERIAI - Carbon Steel
FINI$ - Mil Galvanized -
UL Listed: EX 4231. EX 2551 t
PATENT - No. 6.648,278,
FUNC]jQN - To support horizontal piping - CPVC, Copper or Steel
A listed hanger in all 3 mounting position, i.e. side of vertical surface and
both topside and underside of horizontal surface.
A listed retrainee providing vertical and later restraint in all the above
mounting positions.
To prevent upward movement of pipe that supplies a pendent sprinkler
below the ceiling.
To 5abilize vertical piping by providing horizontal restraint.
INSTALLATION - Per NFPA 13D. Space by pipe type.
Install on wood, concrete or steel.
Snap over pipe, then squeeze strap back allowing pipe to slide freely.
When # 905 threads are exposed in wood, insali #906 backing nut. V
_
FTEWOCD' UL Listed per NFPA 13 R..;
CPVC pipe - #905 screw - no pre -drill
Capper pipe 905 screw - no pre -drill
Steel pipe - 1 4"x1 1/2" log screw - no pre -drill i w
Thru 5 8" gypsum board - 1/4%2" lag screw
*93EEJL?tsted per NFPA 13 - mm 18 GA
CPVC pipe - 1 /4" or #14 Tek Screw
Capper pipe - 1 /4" or #14 Tek Screw
Steel pipe - 1/4" or #14 Tek Screw
*CONCt911-ted minimum load each fastener
Thd 7Mg&w QWE0+2501bs
" 1 12" Offset - pipe wall to mounting surface
" 3/4' and 1" pipe size made with common center -line t
* Leg design produces superior strength 'tee
•Offset ed a eliminates abrasion
* AFCON J905 screw listed for wood has 5-16" hex head - included
Nominal Pipe Sae (in.)
'l."
1"
1'/0
1'%*
2'
2'W
3"
3%'
4'
5"
8"
8"
Steel pipe ex"W threaded
NIA
12'-0'
12'-0"
16-0"
W-0"
W-0-
16-T
15'.0'
15'-0'
15'-0'
15'-0"
i v 0'
light,,
Threaded lightwall steel
WA
12'-0'
12'-T
12A"
12'-0"
12'-0'
12'-0"
WA
NIA
WA
NIA
WA
pipe
Copper tube
oppe
W-O'
V-O'
10'-V
10'-0"
1 Z'-O'
12'-0'
12'-V
15-0"
15'-0"
16-0"
1 5'-0'
S'
1 -0"
CPVC
5d5"
F-0'
6'-"
7'.D"
B'-0"
9-0-
10'-0-
WA
NIA
WA
WA
WA
PolybuVene (IIPS)
WA
T-9
4'-T"
5'-D
T-11"
WA
WA
WA
NIA
WA
NIA
NIA
Polybutylene (CTS)
2' 11"
T-4'
3'-11"
4'S'
S'S"
WA
WA
WA
NIA
NIA
NIA
WA
Duc61e iron pipe
WA
WA
NIA
NIA
NIA
15'-0"
WA
WA
15-0'
WA
IF-0"
IV-0"
514 STEEL - COPPER - C P. V C HANGER
NOT TO SCALE
DESIGN C14I TERIA
CONCEALED RES. PENDENT SPRINKLER
UPRIGHT QUICK RESPONSE SPRINKLER
RES. PENDENT SPRINKLER
0 CHANGE IN ELEVATION
ARISER LOCATION (PER DETAIL)
NODE POINT FOR CALCULATION
HANGER TIC DETAIL
SYMBOL LEGEND
SIZE & PIPE TYPE -
314" THRU 3" C.P.V.C. PIPE
LISTINGS - -;-
UL LISTED, EX4231, EX 2551
INSTALLATION - PER NFPA 130
INSTALL ON TOP, BOTTOM OR SIDE OF BUILDING ELEMENT,
SPACE BY PIPE TYPE
FASTENERS- a
in WOOD: o
314" - 3" CPVC PIPE - #9C, SCREW - NO PRE --❑RILL
in STEEL:
314" - 3" CPVC PIPE - 114" OR #14 TEK SCREW
Nominal Pipe Size (in.)
N.
1"
1'/."
1 %'
2-
2,h'
3'
3y,-
4"
S'
6'
8'
Steel pipe excaptthreaded
lightwall
NIA
12'-0'"
12'-0'
15'-0"
16-0"
15'4"
15'-0"
15'-V
16-V
16-W
15'-0"
IS -ow
Threaded lightwall steel
pipe
WA
12'-0"
12'-0'
12'-0"
12'-0"
12'-0"
12'-T
NIA
NIA
NIA
NIA
WA
Cappertube
8'-17
6'-0"
1V-0"
10'-0"
12'-0"
12'4Y
12'-0'
ITV
IT-V
164r
164r
16-T
CPVC
V-6-
6-0"
6!-6-
T-0"
V-0'
9'4"
10'-0"
WA
NIA
WA
WA
wA
Polybutylene (IPs)
NIA
F-7
4'-7"
sv
5'-11"
WA
WA
WA
WA
WA
NIA
WA
Poloulylene (CTS)
2'-11"
Y-4-
N-11"
4'-5"
65"
WA
WA
TWA
WA
WA
WA
WA
Ductile Iran pipe
WA
NIA
WA
NIA
MIA
16-0"
NIA
WA
15'-0"
WA
I8'-V
15'-0'
510 STEEL - COPPER - C. P. V. C. HANGER
NOT TO SCALE
0
I � �
Nominal Pipe Size (in.)
'I"
1'
#'!,'
1 %"
2"
2W
3'
3'I/V
4"
5'
6"
81
Steel pipeexoepl11-aded
Ilghtwall
WA
17-0"
17-0"
16'-0'
15-0"
15'-0"
1V-0-
15'-0"
15'-0"
16-0.
15`-0"
15,0"
Threaded iighiwall steel
WA
12-0'
1x-0"
12'4'
IZ-O'
12'-0"
12'-("
WA
WA
WA
NIA
WA
pipe
Copper tube
8'-0"
K-O'
W-0"
I O'-0'
12'-0'
12'-a"
12'-T
15'-0"
15'-0"
15'-0'
16-0"
16'-0"
CPVC
5W
6'-0"
V-6"
T-0"
6-0"
9'-0'
10'-T
NIA
WA
WA
NIA
NIA
F*butylenellPs)
NIA
3-9'
4'-T'
5'-0'
5'-11'
WA
WA
NIA
WA
WA
NIA
WA
Paiybutylene(CTS)
2'-11"
31-4'
3'-11,
4'-5'
S' 5"
WA
WA
NIA
WA
WA
NIA
WA
Ductile iron pipe
NIA
NIA
WA
WA
NIA
IF-O"
WA
NIA
IT-W
WA
19-0"
16-0"
515 STEEL - COPPER - C. P. V C. HANGER
NOT TO SCALE
Dcm
38
�i
36
35
34
.00
32 .� s N
�� 27
28
29
AVEN E 54
pax 9
��-
L�
...x.
AIRPORT
BOULEVARD
.
WEISK(]P
AVENUE 58
VICINITY MAP
30 2
N.
25
'
24
N"t
23
39
�-22 7
NIka 2 1€ 1 1 > 7
' <86 74
F -1 85 /75
83 9:
77
81
80
SAY WAY
`"` ,
79
011
JNE
tt sELEVATION: 490
i <iGUTTER
'rl
k IRB�... - - SRC -'�t�
LL ,44 I Lam,++ V� -
2
'BALL. � �
3 I
4 #
low wMaw
) ER � 6
I
i
7
E x
s 8
9
' 1 10
NL
67
5
54
12 /13
35
f-`94 36
I
Sin
W-37
-
38 34
!39
_j 40 3
32
52
5 I 4
49 48147 '" I I 46 44 43
3029
a.
el
1 r p
-- 2826
27
425
`
SITE WA TER PLAN
N.T.S.
CPVC TO SYSTEM
T R 19' ELEV.
U
14" x 14" VCPVC RISER
ACCESS DOOR �-
300 PSI PRESSURE GAUGE
MAIN DRAIN VALVE �
1I2" DRAIN TO EXTERIOR TO DOMESTIC
REGULATOR SET @ "XX" PSI
BY PLUMBING CONTRACTOR
RUBBER FACED CHECK VALVE -POINT OF CONNECTION
a PSI LOSSFOR FIRE SPRINKLER
5 GPM ALLLOWARNCE
900 INTO BUILDING '- )R1" CPVC
2' ELEV.
X
FINISH GRADE
V ELEV.
1 %11 CPVC
314" METER
10 PSI LOSS
STATIC 73 -10% =65.7 PSI
RESIDUAL 20 -10% = 18 PSI
FLOW 1500 GPM
WATER FLOW INFORMATION
PER NFPA 13D 2013:
NO SPARE SPRINKLERS
SHALL BE REQUIRED
TO BE PROVIDED
SECTION 5.1 .1 .1
I ' TAP INTO
WATirR MAI N
1Y2"CPVC 1" COPPER K
E E METER CMA1%
1
-T ELEV. M 1 M 5 MAX HODEP]IKTS�n
'���� Iy1DRA1J61C Rereaerace
-3' ELEV.
-T ELEV.
HOT& roaTAGE5 '*Be
WOP$T CP5E SCENARIO
RISER AND UNDERGROUND DETAIL
UNDERGROUND BY OTHERS N.T.S.
APPROVAL
Riverside County Fire Department
Offi t e ar
By. r,
Kahl Hetift
The approval of plans and specifications does riot
permit the violation, deletion, omission or faulty
Installation of any requlrements of Title 24 or any
Lao; Ordinances. Construction shall remain
a. ssible and exposed for inspection purposes until
approved by the Fire Department.
pppp
APPROVAL STAMP
1421
MECHANICAL
LICENSE NO. 890694
■
CUSTOM, TRACT, MULTI -FAMILY
AND COMMERCIAL
0
DESIGN, ENGINEERING AND
INSTALLATION
9225 STELLAR COURT SUITE A
CORONA, CA 92883
PH - 951-667-4220
FAX - 951-667-4216
•
The recipient of these plans hereby
acknowledges that all plans, details,
specifications or methods of
installation contained in this set of
pplans is the sale property of NP
MECHANICAL, INC. and thaany use
of this set of plans is prohibited and is
a violation of copyright laws without
first receivingg permission from Fire
Sprinkler Sys ems_
C,l ON
_n
40 CLASSIFICATION
C-1 5
LICENSE NO.
890694
of � ��
CA
w U)
m Lu
< < LL LL LL.LL
II] V7 uj UJ
�a- r cOi'7rr
Llk mr
U7 Z 2 LU CL, M ¢ cv
z
� ~ <Qa dd¢l� D
CD 000� Lu
J LLI ~ � ~ < cI}
O Z � ❑ IY
Q d T-N
2
REVISIONS
NO. DATE I DESCRIPTION
� W
F-3W
U) Z
uu a7 O
W Z s
�0 ce)
i 'E Z
LLl < J
CLq;r
IL 00
PAGE NAME: GENERAL NOTES
DATE
03I2512016
DESIGNER
M. GARCIA
SHEET SIZE
24" X 36"
F SHEET IS LESS THAN 24-:X 36"
IT IS A REDUCED PRINT SCALE
REDUCE ACCORDINGLY
SCALE: 114'=V-0"
JOB NUMBER: F-0000
FP1
0
_.—_1._A __'; "' T
L... !- - -- - -1
OL.0 I IUI'Y U
SCALE: 1/81,= 1'
1ST FLOOR
SCALE: 1/411 = 1'
IIrI- �lll
FIREPLACE OPT. AT DINING
SCALE:'/4" = 1'
FiH. TLR1
1
i
1 FIN. FLFL
SEUIlull C
SCALE; 1181,=1'
i
IJPPB
CASITA
9-0' CLG
}
`0a
CH
04
jOPT.
n
ALT. RISER LOCATION
SCALE:1/4" = 1
1 ,
3EA 3 H�
19 D5
Fr.
�a
HB W/
S.Q.V.
2ND FLOOR
SCALE:1/4" = 1'
Sprinkler Head Schedule
SYmbol
Count
Thread
K—Factor
Description
Nate
8
1/2"
4.9
RELIABLE FIRES49 7/16 FIR 175 BB PD
on Drop
•
28
1/2"
4.9
RELIABLE RFC49 7/16 FR 165 82 CC
on Drop
36 = Total Number of Heads This Floor
THIS BUILDING IS PROTECTED
BY A HYDRAULICALLY DESIGNED
AUTOMATIC SPRINKLER SYSTEM
PER NFPA 13D, 2013 EDITION
LOCATION I CALC AREA 1
NO. OF SPRINKLERS 1
BASIS OF DESIGN
DENSITY: 1 .05 GP+vsa-FT-
DESIGNED AREA OF DISCHARGE
1 HEADCALC- 40U sQ-PT.
SYSTEM DEMAND AT THE BASE OF RISER
GPM DISCHARGE 20.024 GPM
RESIDUAL PRESSURE 27.790 Psa
SYSTEM DEMAND AT SOURCE
GPM DISCHARGE 25.024 GPM
RESIDUAL PRESSURE 55.118 PSI
*SAFTEY FACTOR 10-558 PSI
HYDRAULIC — SYSTEM
THIS BUILDING IS PROTECTED
BY A HYDRAULICALLY DESIGNED
AUTOMATIC SPRINKLER SYSTEM
PER NFPA 13D, 2013 EDITION
LOCATION I CALC AREA 2
NO. OF SPRINKLERS 2
BASIS OF DESIGN
DENSITY: 1 .05 GPMersQ.FT.
DESIGNED AREA OF DISCHARGE
2 HEAD CALC. 256 SO -FT.
SYSTEM DEMAND AT THE BASE OF RISER
GPM DISCHARGE 2e GPM
RESIDUAL PRESSURE 20.063 Psi
SYSTEM DEMAND AT SOURCE
GPM DISCHARGE 31 GPM
RESIDUAL PRESSURE 53-w Psi
*SAFTEY FACTOR 12.5W PSI
HYDRAULIC — SYSTEM
THIS BUILDING IS PROTECTED
BY HYDRAULICALLY DESIGNED
AUTOMATIC SPRINKLER SYSTEM
PER NFPA 13D, 2013 EDITION
LOCATION I CALC AREA s
NO. OF SPRINKLERS 2
BASIS OF DESIGN
DENSITY: 1.05 ePMlrso Fr,
DESIGNED AREA OF DISCHARGE
2HEADCAI.C. 256 SQ_PT.
SYSTEM DEMAND AT THE BASE OF RISER
GPM DISCHARGE 26,403 GPM
RESIDUAL PRESSURE 22.6w Psi
SYSTEM DEMAND AT SOURCE
GPM DISCHARGE 31.403 GPM
RESIDUAL PRESSURE: 56.043 Psi
*SAFTEY FACTOR im PSI
dYDRAU LI C — SYSTEM
THIS BUILDING IS PROTECTED
BY A HYDRAULICALLY DESIGNED
AUTOMATIC SPRINKLER SYSTEM
PER NFPA 13D, 2013 EDITION
LOCATION I ALT. CALC AREA 1
NO. OF SPRINKLERS
BASIS OF DESIGN
DENSITY: I05 aPzlrsa.FT.
DESIGNED AREA OF DISCHARGE
1 HEAD CALC. 400 SO. I L
SYSTEM DEMAND AT THE BASE OF RISER
GPM DISCHARGE 20,024GPM
RESIDUAL, PRESSURE 27.841 PSI
SYSTEM DEMAND AT SOURCE
GPM DISCHARGE 25.024 GPM
RESIDUAL PRESSURE 55.169 PSI
*SAFTEY FACTOR 10.507 PSI
HYDRAULIC — SYSTEM
THIS BUILDING IS PROTECTED
BY A HYDRAULICALLY DESIGNED
AUTOMATIC SPRINKLER SYSTEM
PER NFPA 13D, 2013 EDITION
LOCATION I ALT, CALC AREA 2
NO. OF SPRINKLERS 2
BASIS OF DESIGN
DENSITY: Las Gpwso.Fr.
DESIGNED AREA OF DISCHARGE
2 HEAD CALC. 256 SQ.FT.
SYSTEM DEMAND AT THE BASE OF RISER
GPM DISCHARGE 1 26.001 GPM
RESIDUAL PRESSURE 1 20.148 PS!
SYSTEM DEMAND AT SOURCE
GPM DISCHARGE 31.001 GPM
RESIDUAL PRESSURE 53.163 Psi
*SAFTEY FACTOR 12.501 Psi
HYDRAULIC — SYSTEM
THIS BUILDING IS PROTECTED
BY A HYDRAULICALLY DESIGNED
AUTOMATIC SPRINKLER SYSTEM
PER NFPA 13D, 2013 EDITION
LOCATION I ALT. CALC AREA 3
NO. OF SPRINKLERS 2
BASIS OF DESIGN
DENSITY: 1.05 GPMISQ.Fr.
DESIGNED AREA OF DISCHARGE
2 HEAD CALC. 256 So. FT.
SYSTEM DEMAND AT THE BASE OF RISER
GPM DISCHARGE 28-404 GPM
RESIDUAL PRESSURE 21.410 Psi
SYSTEM DEMAND AT SOURCE
GPM DISCHARGE 31.404 GPM
RESIDUAL PRESSURE 54.a34s Psa
*SAFTEY FACTOR 10,818 Pia
NOTES:
A. ALL HEAD SPACING TO BE 1b'X16I, UNLESS OTHERWISE NOTED.
B. A 20X20 HEAD TO BE USED IN COMPARTMENTS LESS THAN 400 SO,
FT. AND LESS THAN 20 FT. IN EACH DIRECTION.
C. ALL PIPES TO BE 1" CPVC, UNLESS OTHERWISE NOTED.
D. ALL HEAD DROPS TO BE 1" CPVC, UNLESS OTHERWISE NOTED.
E. HANGERS SHOWN FOR REFERENCE PURPOSES ONLY, HANGER
SPACING TO BE PER TABLES ON THIS SHEET. ALL PIPING
INSTALLED WITHIN THE ATTIC SHALL BE PROVIDED WITH
INSULATION ON THE ATTIC SIDE OF THE PIPING TO AVOID
EXPOSURE OF THE PIPES RATED TEMPERATURE,
PER NFPA 13D EDITION EXCLUDING:
1❑. 8.2.5.7 SHADOW AREAS: SHADOW AREAS SHOULD BE PERMITTED IN
THE PROTECTION AREA OF A SPRINKLER AS LONG AS THE
CUMULATIVE DRY AREAS DO NOT EXCEED 15 SQ. FT. PER
SPRINKLER
0 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS 55 SQ,
FT. AND LESS
0 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,
LINEN CLOSETS, AND PANTRIES THAT MEET ALL OF THE
FOLLOWING CONDITIONS:
1. THE AREA OF THE SPACE DOES NOT EXCEED 24 SQ, FT.
2. THE SHORTEST DIMENSION DEOS NOT EXCEED 3 FT.
3. THE WALLS AND CEILINGS ARE SURFACED WITH
NONCOMBUSTIBLE OR LIMITED —COMBUSTIBLE MATERIALS
AS DEFINED IN NFPA 220.
j 8.2.5.1 CLOSETS: IN ALL CLOSETS AND COMPARTMENTS INCLUDING
THOSE SOUDING MECHANICAL EQUIPMENT, THAT ARE NOT
LARGER THAN 400 `P A SINGLE PRINKLER AT THE HIGHEST
CEILING SPACE SHALL BE SUFFICIENT WITHOUT REGARD TO
OBSTRUCTIONS OR MINIMUM DISTANCES TO WALL.
8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS
THAT MEET THE FOLLOWING CONDITIONS:
1. THE TOTAL VOLUME OF ALL UNPROTECTED CEILING
DOCKETS IN A COMPARTMENT DOES NOT EXCEED inn FTC
2. THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING
POCKET IS PROTECTED BY THE SPRINKLERS AT THE
LOWER CEILING ELEVATION.
3. THE INTERIOR FINISH OF THE UNPROTECTED CEILING
POCKET EXCLUDING DECORATIVE TREATMENT IS
NONCOMBUSTIBLE OR LIMITED —COMBUSTIBLE MATERIAL.
4. SKYLIGHTS NOT EXCEEDING 32 FP SHALL BE PERMITTED
TO HAVE A PLASTIC COVER.
NP
MECHANICAL
LICENSE NO. 890694
•
CUSTOM, TRACT. MULTI -FAMILY
AND COMMERCIAL
•
DESIGN, ENGINEERING AND
INSTALLATION
•
9225 STELLAR COURT SUITE A
CORONA, CA 92883
PH _ 951-667-4220
FAX - 951-667-4216
a
The recipient of these plans hereby
acknowledges that all plans, details,
specifications or methods of
in,
contained in this set of
plans is the sale property of NP
MECHANICAL, INC. andthat any use
of this set of plans is prohibited and is
a violation of copyright laws without
first receiving permission from Fire
Sprinkler Systems.
Q.� �'
CLASSIFICATION 0
C-16
* LICENSE NO.
s 890694OF
Cf1
CIO
1—
Uj
>
W
co
Q
3
LL LL
LL LL
� �
�
C!} CI7
(A UJ
J
f2CN
C)r >-
W
r
C9 ci U
OD cf)
rn Co
r r
0) -
Q
�
U)
z
W
a
�•'
Z
C) o_
I(
z
z
Q~
1�
z��
QUJ
Q`�J
p0<U
❑
U
❑
U fY
U)
rL
0 4
0 �
Lu
J
U
W
H-�
LLLL
F-Q
0
❑
❑ o
v~i z
w
m
d
>
C
NOTES
REVISIONS
NO. DATE I DESCRIPTION
L_
(1)
>_
w
w
_..,
C%4 Z
w
z
0)p
=
�
0
C�)CL
z:E
U)
J
<<
w
<
j"T
DD
PAGE NAME: PIPING PLAN
DATE
03/2512016
DESIGNER
M- GARCIA
SHEET SIZE
24" X 36"
IF SHEET IS LESS THAN 24' X36"
T IS A REdUCED PRINT SCALE
REDUCE ACCORDINGLY
SCALE: 114"=1'-0"
r a
JOB NUMBER: F-0000
FP2
ZDate:
Residential Connection Charge Estimate
June 28, 2016
Customer Name:
RREF II- CWC LAQ, LLC
Phone No.
(760) 918-6768
Parcel No.
775-410-014
Geo.
06-07-16-3
Address:
80444 Champions Way, La Quinta
LID:
887912 Block No.
Lot No.
74 size of Lot:
6,970
sq. ft. Tract No. 36537-1
Type of Service:
JEl
R-1: LJ Duplex:
Triplex:
Apts: ❑
SWSC:
$
- Acres:
0.16
SWSC: $13,011.00 /acre
WSBFC:
$
-
SCC:
$
40851.00
Treatment:
$2,436/edu collection: $2,415/edu
Meter:
$
'S9C Meter Size:
'+
inch
Meter surcharge:
$
- Service Size:
inch
Service:
$
_
Meter & Service:
$ -
Backflow:,
$
Other:
$ -
Sewer Lateral:
$
Total:
$
nician: Ruben Montiel Fees
Information Supplied By Customer
uVn1e51E1c vvazer uemano
Max. Flow--:
Min. Pressure -
Fire Sprinkler Demand*
Max. Flow=
Min. Pressure=
System Type: 0
Multi
24 gpm
37.5 psi
31.4 gp m
27.4
El
Stand Alone
* CVWD USES WORST CASE CONDITION
Notes: Tract No. 36537-1, Per Wellsite Agreement, no WSBFC.
All SWSC paid on PZ 15-6563. Collect only SCC. PZ 16-
6897
CVWD System Data
Service Connection**
Max. Flow*= ?j . y gpm
Inlet Pressure' I Ll psi
Outlet Pressure= i . n lisi
I Meter Size = 3/� inch
Service Size= 1 inch
1 Prior to Pressure Re u lat! ng Valve
** For Calculation Pur oses- Service Connection Includes:
Service Connection Pipe=50', Meter Stop, Meter, Check Valve & Shut Off Valve
Lake Cahuilla Calculations:
PZ= . Res. # =.6725 Res./Ht=32
HGL= 145' Property Elev.= -4'
Ps = 71.4 psi Po = 32.0 psi
1" Service hL = 23.6 psi
3/4" Meter hL = 15.8 psi
Appoved by: Jesse Aguilar
The meter sizing is for plan check purposes only. The ultimate responsibility resides with the Enei
6gRti'rESs1 ,
AC,V�
C 79673 rq
spa civil
lF OF C 11;' Of �
Date: 7-11-16
eer-of-Record for the Droie
*********This is just a QUOTE, all fees are subject to Change*********
(Rev. 9/15)
MECHANICAL
NP Mechanical
9225 Stellar Court, Suite A
Corona, CA 92883
951-667-4220
Job Name
: ESTATES
Building
: PLAN 3
Location
CALC AREA 1
System
Contract
Data File
PLAN3 CA1 20X20.WXF
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
NP Mechanical Page 1
ESTATES Date 03/28/16
HYDRAULIC DESIGN INFORMATION SHEET
Name - ESTATES Date - 03/28/16
Location - CALC AREA 1
Building - PLAN 3 System No. -
Contractor - NP MECHANICAL Contract No. -
Calculated By - M.G. Drawing No. - 1
Construction: (X) Combustible ( ) Non -Combustible Ceiling Height 10'0"
OCCUPANCY - LIGHT HAZARD
S Type of Calculation: ( )NFPA
13 Residential
( )NFPA 13R (X}-NFPA n b
Y Number of Sprinklers Flowing:10
( )2
( )4 ( )
S ( ) Other
T ( )Specific Ruling
Made by
Date
E
M Listed Flow at Start Point
- 20 WGpm
System Type
Listed Pres. at Start Point
- 16.7 Psi
(X) Wet ( ) Dry
D MAXIMUM LISTED SPACING 20
x 20'
( ) Deluge ( ) PreAction
E Domestic Flow Added
-35 Gpm
Sprinkler or Nozzle
S Additional Flow Added
- Gpm Make
RELIABLE Model RFC49
I Elevation at Highest Outlet
- Feet Size
7/16 K-Factor 4.9
G Note:
Temperature Rating 165
N
Calculation Gpm Required 20.024
Summary C-Facto- used:
Psi Required 27,790
Overhead 150
� BR
Underground 150
W Water Flow Test:
Pump Data:
Tank or Reservoir:
A Datc of Tcot -
Rated Cap.
Cap.
T Time of Test -
@ Psi
Elev.
E Static (Psi) - 73
Elev.
R Residual (Psi) - 20
Other
Well
Flow (Gpm) - 1500
Proof Flow Gpm
S Elevation -
P Location:
P
L Source of Information:
Y
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Water Supply Curve C
NP Mechanical
ESTATES
Page 2
Date 03/28/16
City Water Supply: Demand:
Cl - Static Pressure 65.7 D1 - Elevation 9.961
C2 - Residual Pressure: 18 D2 - System Flow : 20.024
C2 - Residual Flow 1500 D2 - System Pressure 55.118
Hose (❑emand) : 5
D3 - System Demand : 25.024
Safety Margin 10.558
150
140
130
P 120
R 110
E 100
S 90
S 80
U 70
—
D2
R 60
E 50 D3
40
30
C2
20
10
D1
200 400 600 800 1000 1200 1400 1600 1800
FLOW (N 1 1.85)
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Fittings Used Summary
NP Mechanical
ESTATES
Fitting Legend
Abbrev.
Name
1/2
3/4 1
E
NFPA 13 90' Standard Elbow
1
2 2
F
NFPA 13 45' Elbow
1
1 1
N '
CPVC 90'EII Harvel-Spears
7 7
0'
CPVC Tee - Branch
3
3 5
P '
CPVC 45' Elbow
1
1 1
R '
CPVC Coupling Tee - Run
1
1 1
S
NFPA 13 Swing Check
0
0 5
T
NFPA 13 90' Flow thru Tee
3
4 5
Units Summary
Page 3
Date 03/28/16
11/4
11/2
2
21/2
3
31/2
4
5
6
8
10
12
14
16
18
20
24
3
4
5
6
7
8
10
12
14
18
22
27
35
40
45
50
61
1
2
2
3
3
3
4
5
7
9
11
13
17
19
21
24
28
8
9
11
12
13
0
0
0
0
0
0
0
0
0
0
0
0
6
8
10
12
15
0
0
0
0
0
0
0
0
0
0
0
0
2
2
2
3
4
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
2
2
0
0
0
0
0
0
0
0
0
0
0
0
7
9
11
14
16
19
22
27
32
45
55
65
6
8
10
12
15
17
20
25
30
35
50
60
71
81
91
101
121
Diameter Units
Inches
Length Units
Feet
Flow Units
US Gallons per Minute
Pressure Units
Pounds per Square Inch
Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters.
Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors
of 120 except as noted with *. The fittings marked with a' show equivalent lengths values
supplied by manufacturers based on specific pipe diameters and CFactors and they require no
adjustment. All values for fittings not marked with a * will be adjusted in the calculation
for CFactors of other than 120 and diameters other than Sched 40 per NFPA.
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Pressure / Flow Summary - STANDARD
NP Mechanical
Page
4
ESTATES
Date
03/28/16
Node Elevation K-Fact
Pt
Pn
Flow Density
Area
Press
No.
Actual
Actual
Req.
H1 12.0 4.9
16.7
na
20-02 0.05
400
16.7
H2 12.0
18.38
na
H3 12.0
18.57
na
H4 20.0
16.97
na
H5 20.0
16.97
na
D1 13.0
16.81
na
1 13.0
17.51
na
2 13.0
17.9
na
D2 13.0
17.94
na
3 13.0
17.94
na
D3 13.0
18.14
na
4 13.0
18.14
na
5 13.0
18.29
na
6 13.0
18.7
na
7 11.0
19.72
na
8 11.0
20.54
na
9 11.0
21.18
na
10 11.0
20.92
na
22 11.0
20.83
na
12 11.0
20.53
na
13 11.0
20.33
na
B 11.0
19.23
na
C 13.0
18.17
na
14 11.0
18.83
na
15 11.0
18.62
na
16 11.0
18.42
na
D4 21.0
16.53
na
19 21.0
16.53
na
20 21.0
16.52
na
D5 21.0
16.54
na
18 21.0
16.55
na
17 11.0
20.9
na
TR 11.0
22.01
na
BR 2.0
27.79
na
5.0
X 2.0
28.41
na
EL -3.0
30.76
na
M1 -3.0
31.69
na
M2 -3.0
42.23
na
CM -3.0
51.64
na
102 -3.0
51.65
na
101 -3.0
51.65
na
100 -3.0
51.65
na
SRC -11.0
55.12
na
The maximum velocity is 16.59 and it occurs in the pipe between nodes M1 and M2
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Final Calculations - Hazen -Williams
NP Mechanical
ESTATES
Page 5
Date 03/28/16
Hyd.
Qa Dia.
Fitting
Pipe
Pt
Pt
Ref.
"C"
or
Ftng's
Pe
Pv **'*'** Notes ******
Point
Qt Pf/Ft
Eqv. Ln,
Total
Pf
Pn
H 1
20.02 1.101
N 7.0
1.000
16.700 '
to
150.0
0.0
7.000
-0.433
D1
20.02 0.0681
0.0
8.000
0.545
D2
H3
to
D3
H4
to
D4
H5
0.0
1.101
N
7.0
1.000
18.375
150.0
0.0
7.000
-0.433
0.0
0.0
0.0
8.000
0.0
0.0
0.0
17.942
0.0
1.101
N
7.0
1.000
18.571
150.0
0.0
7.000
-0.433
0.0
0.0
0.0
8.000
0.0
0.0
0.0
18.138
0.0
1.101
N
7.0
1.000
16.968
150.0
0.0
7.000
-0.433
0.0
0.0
0.0
8.000
0.0
0.0
0.0
16.535
0.0
1.101
N
7.0
1.000
16.971
1500
0.0
7.000
-0.4$3
0.0
0.0
0.0
8.000
0.0
0.0
0.0
16.538
K Factor = 4.90
Vel = 6.75
K Factor = 4.88
Vet = 0
K Factor = 0
Vel = 0
K Factor = 0
Vel = 0
K Factor = 0
Vel =0
K Factor = 0
D 1
20.02
1.101
O
5.0
5.250
16.812
to
150.0
0.0
5.000
0.0
1
20.02
0.0682
0.0
10.250
0.699
Vel =
6.75
1
-6.89
1.101
3 R
3.0
9.417
17.511
to
150.0
0.0
3.000
0.0
2
13.13
0.0313
0.0
12.417
0.389
Vel =
4.42
2
-3.83
1.101
R
1.0
1.583
17.900
to
150.0
0.0
1.000
0.0
3
9.3
0.0163
0.0
2.583
0.042
Vel =
3.13
0.0
9.30
17.942
K Factor = 2.20
D2
0.0
1.101
O
5.0
1.250
17.942
to
150.0
0.0
5.000
0.0
3
0.0
0.0
0.0
6.250
0.0
Vel =
0
3
9.30
1.101
R
1.0
10.833
17.942
to
150.0
0.0
1.000
0.0
4
9.3
0.0166
0.0
11.833
0.196
Vel =
3.13
0.0
9.30
18.138
K Factor = 2.18
D3
0.0
1.101
O
5.0
1.250
18.138
to
150.0
0.0
5.000
0.0
4
0.0
0.0
0.0
6.250
0.0
Vel
= 0
4
9.30
1.101
N
7.0
2.417
18.138
to
150.0
0.0
7.000
0.0
5
9.3
0.0165
0.0
9.417
0.155
Vel
= 3.13
Computer Programs by Hydratec Inc. Route 111
Windham N.H.
USA 03087
Final Calculations - Hazen -Williams
NP Mechanical
Page 6
ESTATES
Date 03/28/16
Hyd.
Qa
Dia.
Fitting
Pipe
Pt Pt
Ref.
"C'
or
Ftng's
Pe Pv
*******
Notes ******
Point
Qt
Pf/Ft
Eqv.
Ln.
Total
Pf Pn
5
0.0
1.101
R
16.667
18.293
1.0
to
150.0
N
7.0
8.000
0.0
6
9.3
0.0165
0.0
24.667
0.407
Vel
= 3.13
6
0.0
1.101
N
7.0
2.000
18.700
_
to
150.0
0.0
7.000
0.866
7
9.3
0.0166
0.0
9.000
0.149
Vel
= 3.13
7
0.0
1.101
511
5.0
40.083
19.715
to
150.0
O
5.0
10.000
0.0
8
9.3
0.0165
0.0
50.083
0.827
Vel
= 3.13
8
2.19
1.101
2R
2.0
19.250
20.542
to
150.0
O
5.0
7.000
0.0
9
11.49
0.0244
0.0
26.250
0.641
Vel
= 3.87
0.0
8
-2.19
1.101
to
150.0
12
-2.19
-0.0012
0.0
-2.19
9
-8.53
1.101
to
150.0
10
-8.53
-0.0141
10
6.59
1.101
to
150.0
11
-1.94
-0.0008
0.0
-1.94
_
10
-6.59
1.101
to
150.0
22
-6.59
-0.0087
22
8.53
1.101
to
150.0
21
1.94
0.0009
0.0
1.94
22
-8.53
1.101
to
150.0
12
-8.53
-0.0141
12
to
13
13
to
B
B
to
C
C
to
14
-2.19 1.101
150.0
-10.72-0.0215
0.0 1.101
21.183
K Factor = 2.50
2R
2.0
12.667
20.542
0.0
2.000
0.0
0.0
14.667
-0.017
Vel = 0.74
20.525
K Factor = -0.48
R
1.0
12.667
21.183
O
5.0
6.000
0.0
0.0
18.667
-0.263
Vel = 2.87
N
7.0
0.583
20.920
0.0
7.000
4.764
0.0
7.583
-0.006
Vel = 0.65
R 1.0
4.917
O 5.0
6.000
0.0
10.917
N 7.0
0.583
0.0
7.000
0.0
7.583
O 5.0
0.0
N 7.0
0.0
0.0
4R 4.0
14.333
7.000
21.333
2.083
7.000
25.678
20.920
0.0
-0.095
20.825
4.764
0.007
25.596
20.825
0.0
0.0
-0.195
20.330
K Factor = -0.38
Vel = 2.22
Vel = 0.65
K Factor = 0.38
Vel = 2.87
Vel = 3.61
150.0
N
7.0
11.000
0.0
-10.72
-0.0215
0.0
51.083
-1.097 Vel = 3.61
0.0
1.101
N
7.0
2.000
19.233
150.0
0.0
7.000
-0.866
-10.72
-0.0214
0.0
9.000
-0.193 Vel = 3.61
0.0
1.101
R
1.0
4.000
18.174
150.0
O
5.0
6.000
0.866
-10.72
-0.0215
0.0
10.000
-0.215 Vel = 3.61
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Final Calculations - Hazen -Williams
NP Mechanical
Page 7
ESTATES
Date 03/28/16
Hyd.
Qa
Dia.
Fitting
Pipe
Pt Pt
Ref.
"C"
or
Ftng's
Pe Pv
"" "' Notes
Point
Qt
Pf/Ft
Eqv.
Ln.
Total
Pf Pn
14
6.89
1.101
R
1.0
12.667
18.825
to
150.0
O
5.0
6.000
-0.866
2
-3.83
-0.0032
0.0
18.667
-0.059
Vel = 1.29
0.0
-3.83
17.900
K Factor = -0.91
14
-6.89
1.101
R
1.0
13.500
18.825
to
150.0
N
7.0
8.000
0.0
15
-6.89
-0.0094
0.0
21.500
-0.203
Vel = 2.32
15
0.0
1.101
R
1.0
12.750
18.622
to
150.0
N
7.0
8.000
0.0
16
-6.89
-0.0095
0.0
20.750
-0.197
Vel = 2.32
16
0.0
1.101
R
1.0
4.000
18.425
to
150.0
0.0
1.000
-0.866
1
-6.89
-0.0096
0.0
5.000
-0.048
Vel = 2.32
0.0
-6.89
17.511
K Factor = -1.65
D4
0.0
1.101
O
5.0
9.917
16.535
to
150.0
0.0
5.000
0.0
19
0.0
0.0
0.0
14.917
0.0
Vel = 0
19
-1.94
1.101
N
7.0
13.333
16.535
to
150.0
0.0
7.000
0.0
90
-1.94
-0.0009
0.0
20.333
-0.019
Vel = 0.65
20
0.0
1.101
N
7.0
10.000
16.516
to
150.0
0.0
7.000
9.095
21
-1.94
-0.0009
0.0
17.000
-0.015
Vel = 0.65
0.0
-1.94
25.596
K Factor = -0.38
19
1.94
1.101
R
1.0
2.083
16.535
to
150.0
0.0
1.000
0.0
D5
1.94
0.0010
0.0
3.083
0.003
Vel = 0.65
D5
0.0
1.101
N
7.0
2.000
16.538
to
150.0
0.0
7.000
0.0
18
1.94
0.0009
0.0
9.000
0.008
Vel = 0.65
18
0.0
1.101
R
1.0
13.750
16.546
to
150.0
2P
2.0
10.000
4.331
17
1.94
0.0009
N
7.0
23.750
0.021
Vel = 0.65
17
0.0
1.101
N
7.0
10.000
20.898
to
150.0
0.0
7.000
4.764
11
1.94
0.0009
0.0
17.000
0.016
Vel = 0.65
0.0
1.94
25.678
K Factor = 0.38
9
20.02
1.101
N
7.0
5.167
21.183
to
150.0
0.0
7.000
0.0
TR
20.02
0.0682
0.0
12.167
0.830
Vel = 6.75
0.0
20.02
22.013
K Factor = 4.27
TR
20.02
1.101
2R
2.0
9.000
22.013
to
150.0
S
9.563
18.562
3.898
BR
20.02
0.0682
N
7.0
27.562
1.879
Vel = 6.75
Computer Programs
by Hydratec Inc. Route 111
Windham N.H. USA 03087
Final Calculations - Hazen -Williams
NP Mechanical
ESTATES
Page 8
Date 03/28/16
Hyd.
Qa Dia.
Fitting
Pipe
Pt
Pt
Ref.
"C"
or
Ftng's
Pe
Pv ******* Notes
Point
Qt Pf/Ft
Eqv. Ln.
Total
Pf
Pn
_X
X
to
EL
EL
to
M1
M2
M2
to
CM
5.00 ,
1.101
150.0
25.02
0.1030
0.0
1.598
150.0
25.02
0.0167
0.0 1.598
150.0
25.02
0.0168
0.0
0.785
150.0
25.02
0.5350
0.0
0.995
150.0
25.02
0.1686
CM
0.0
7.68
to
150.0
102
25.02
0.0
102
-20.00
7.68
to
150.0
101
5.02
0.0
101
-3.17
7.68
to
150.0
100
1.85
0.0
100
0.0
7.68
1.85 0.0
101 3.17 7.68
to 150.0
SRC 3.17 0.0
0.0
3.17
102 20.00 7.68
to 150.0
SRC 20.0 0.0
0.0
20.00
O 5.0
1.000
27.790
0.0
5.000
0.0
0.0
6.000
0.618
E 5.828
5.000
28.408
0.0
5.828
2.166
0.0
10.828
0.181
E 5.828
50.000
30.755
0.0
5.828
0.0
0.0
55.828
0.937
0.0
1.000
31.692
0.0
0.0
10.000
0.0
1.000
0.535
T 5.841
50.000
42.227
0.0
5.841
0.0
0.0
55.841
9.417
F 11.278
965.000
51.644
T 43.857
55.135
0.0
0.0
1020.135
0.008
F 11.278
1960.000
51.652
T 43.857
55.135
0.0
0.0
2015.135
0.001
F 11.278
880.000
51.653
T 43.857
55.135
0.0
0.0
935.135
0.0
T 43.857
445.000
51.653
0.0
43.857
3.465
0.0
488.857
0.0
55.118
T 43.857
485.000
51.653
0.0
43.857
3.465
0.0
528.857
0.0
55.118
T 43.857
130.000
51.652
0.0
43.857
3.465
0.0
173.857
0.001
Qa=5
Vel = 8.43
Vel = 4.00
* * Fixed Loss = 10
Vel = 16.59
Vel = 10.32
Vel = 0.17
Vel = 0.03
Vel = 0.01
Vel = 0.01
K Factor = 0.25
Vel = 0.02
K Factor = 0.43
Vel = 0.14
K Factor = 2.69
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
MECHANICAL
NP Mechanical
9225 Stellar Court, Suite A
Corona, CA 92883
951-667-4220
Job Name
ESTATES
Building
PLAN 3
Location
CALC AREA 2
System
Contract
Data File
PLAN3 CA2 16X16.WXF
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
NP Mechanical
ESTATES
Page 1
Date 03/28/16
HYDRAULIC DESIGN INFORMATION SHEET
Name - ESTATES Date - 03/28/16
Location - CALC AREA 2
Building - PLAN 3 System No. -
Contractor - NP MECHANICAL Contract No. -
Calculated By - M.G. Drawing No. - 1
Construction: (X) Combustible ( ) Non -Combustible Ceiling Height 10'0"
OCCUPANCY - LIGHT HAZARD
S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D
Y Number of Sprinklers Flowing: ( )l (X)2 ( )4 ( )
S ( ) Other
T ( )Specific Ruling Made by Date
E
M
D
E
S
I
G
N
Listed Flow at Start Point - 1:3 System Type
Listed Pres. at Start Point - 7 i (X) Wet ( ) Dry
MAXIMUM LISTED SPACING 16 x XMI,
( ) Deluge ( ) PreAction
Domestic Flow Added - 5 Gpm Sprinkler or Nozzle
Additional Flow Added - Gpm Make RELIABLE Model RFC49
Elevation at Highest Outlet - Feet Size 7/16 K-Factor 4.9
Note: Temperature Rating 165
Calculation Gpm Required 26 P,si Requi-red 20.063 1 AT BR
Summary C-Factor Used: Overhead 150 Underground 150
W Water Flow Test: Pump Data: Tank or Reservoir:
A Date of Test - Rated Cap Cap.
T Time of Test - @ Psi Elev.
E Static (Psi) - 73 Elev.
R Residual (Psi) - 20 Other Well
Flow (Gpm) - 1500 Proof Flow Gpm
S Elevation -
P Location:
P
L Source of Information:
Y
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Water Supply Curve C
NP Mechanical
ESTATES
Page 2
Date 03/28/16
City Water Supply: Demand:
Cl - Statfc Pressure 65.7 D1 - Elevation 9.961
C2 - Residual Pressure: 18 D2 - System Flow 26
C2 - Residual Flow 1500 D2 - System Pressure 53.077
Hose ( Demand) 5
D3 - System Demand 31
Safety Margin 12.586
150
140
130
P 120
R 110
E 100
S 90
S 80
U 70
"
R 60
D2
E 50
❑3
40
30
C2
20
10
D1
200 400 600 800 1000 1200 1400 1600 1800
FLOW (N 11 1.85)
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Fittings Used Summary
NP Mechanical
Page
3
ESTATES
Date
03/28/16
Fitting Legend
Abbrev. Name
1/2
3/4
1
11/4
11/2
2
21/2
3
31/2
4
5
6
8
10
12
14
16 18
20
24
E NFPA 13 90' Standard Elbow
1
2
2
3
4
5
6
7
8
10
12
14
18
22
27
35
40 45
50
61
F NFPA 13 45' Elbow
1
1
1
1
2
2
3
3
3
4
5
7
9
11
13
17
19 21
24
28
NCPVC 90'EII Harvel-Spears
7
7
8
9
11
12
13
0
0
0
0
0
0
0
0
0 0
0
0
O' CPVC Tee - Branch
3
3
5
6
8
10
12
15
0
0
0
0
0
0
0
0
0 0
0
0
P' CPVC 45' Elbow
1
1
1
2
2
2
3
4
0
0
0
0
0
0
0
0
0 0
0
0
R' CPVC Coupling Tee - Run
1
1
1
1
1
1
2
2
0
0
0
0
0
0
0
0
0 0
0
0
S NFPA 13 Swing Check
0
0
5
7
9
11
14
16
19
22
27
32
45
55
65
T NFPA 13 90' Flow thru Tee
3
4
5
6
8
10
12
15
17
20
25
30
35
50
60
71
81 91
101
121
Units Summary
Diameter Units
Inches
Length Units
Feet
Flow Units
US Gallons per Minute
Pressure Units
Pounds per Square Inch
Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters.
Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors
of 120 except as noted with *. The fittings marked with a * show equivalent lengths values
supplied by manufacturers based on specific pipe diameters and CFactors and they require no
adjustment. All values for fittings not marked with a * will be adjusted in the calculation
for CFactors of other than 120 and diameters other than Sched 40 per NFPA.
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Prossure / Flow Summary - STANDARD
NP Mechanical
ESTATES
Page 4
Date 03/28/16
Node
Elevation K-Fact
Pt
Pn
Flow Density
No.
Actual
Actual
H1
12.0
7.61
na
H2
12.0 4.9
7.04
na
13.0 0.05
H3
12.0 4.9
7.04
na
13.0 0.05
H4
20.0
7.36
na
H5
20.0
7.37
na
D1
13.0
7.18
na
1
13.0
7.18
na
2
13.0
7.12
na
D2
13.0
6.85
na
3
13.0
7.04
na
D3
13.0
6.85
na
4
13.0
7.04
na
5
13.0
7.33
na
6
13.0
8.07
na
7
11.0
9.21
na
8
11.0
10.73
na
9
11.0
11.77
na
10
11.0
11.35
na
22
11.0
11.2
na
12
11.0
10.71
na
13
11.0
10.43
na
B
11.0
8.84
na
C
13.0
7.7
na
14
11.0
8.25
na
15
11.0
8.16
na
16
11.0
8.07
na
D4
21.0
6.93
na
19
21.0
6.93
na
20
21.0
6.9
na
D5
21.0
6.94
na
18
21.0
6.95
na
17
11.0
11.31
na
TR
11.0
13.12
na
BR
2.0
20.06
na
5.0
X
2.0
20.98
na
EL
-3.0
23.42
na
M1
-3.0
24.81
na
M2
-3.0
35.6
na
CM
-3.0
49.6
na
102
-3.0
49.61
na
101
-3.0
49.61
na
100
-3.0
49.61
na
SRC
-11.0
53.08
na
The maximum velocity is 20.55 and it occurs in the pipe between nodes M1 and M2
Area Press
Req.
256 7.039
256 7 039
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Final Calculations - Hazen -Williams
NP Mechanical
ESTATES
Page 5
Date 03/28/16
Hyd.
Qa
Dia.
Fitting
Pipe
Pt Pt
Ref.
"C"
or
Ftng's
Pe Pv
°"°"' Notes ******
Point
Qt
Pf/Ft
Eqv.
Ln.
Total
Pf Pn
H 1
0.0
1.101
N
7.0
1.000
7.611
to
150.0
0.0
7.000
-0.433
D1
0.0
0.0
0.0
8.000
0.0
Vel = 0
0.0
0.0
7.178
K Factor = 0
H2
13.00
1.101
N
7.0
1.000
7.039
K Factor = 4.90
to
150.0
0.0
7.000
-0.433
D2
13.0
0.0306
0.0
8.000
0.245
Vel = 4.38
0.0
13.00
6.851
K Factor = 4.97
H3
13.00
1.101
N
7.0
1.000
7.039
K Factor = 4.90
to
150.0
0.0
7.000
-0.433
D3
13.0
0.0306
0.0
8.000
0.245
Vel = 4.38
0.0
13.00
6.851
K Factor = 4.97
H4
0.0
1.101
N
7.0
1.000
7.364
to
150.0
0.0
7.000
-0.433
D4
0.0
0.0
0.0
8.000
0.0
Vel = 0
0.0
_
0.0
6.931
K Factor = 0
H5
0.0
1.101
N
7.0
1.000
7.368
to
150.0
0.0
7.000
-0.433
D5
0.0
0.0
0.0
8.000
0.0
Vel = 0
0.0
0.0
D 1
0.0
1.101
O
5.0
5.250
to
150.0
0.0
5.000
1
0.0
0.0
0.0
10.250
1
-4.56
1.101
3R
3.0
9.417
to
150.0
0.0
3.000
2
-4.56
-0.0044
0.0
12.417
2
-8.53
1.101
R
1.0
1.583
to
150.0
0.0
1.000
3
-13.09
-0.0310
0.0
2.583
0.0
-13.09
D2
13.00
1.101
O
5.0
1.250
to
150.0
0.0
5.000
3
13.0
0.0307
0.0
6.250
3
-13.09
1.101
R
1.0
10.833
to
150.0
0.0
1.000
4
-0.09
0.0
0.0
11.833
D3
to
4
4
to
5
6.935
7.178
0.0
0.0
7.178
nn
7.043
6.851
0.0
0.192
7.043
0.0
0.0
K Factor = 0
Vel = 0
Vel = 1.54
Vel = 4.41
K Factor = -4.93
Vel = 4.38
Vel = 0.03
K Factor = -0.03
13.00
1.101
O 5.0
1.250
6.851
150.0
0.0
5.000
0.0
13.0
0.0307
0.0
6.250
0.192 Vel = 4.38
-0.09
1.101
N 7.0
2.417
7.043
150.0
0.0
7.000
0.0
12.91
0.0303
0.0
9.417
0.285 Vel = 4.35
Computer
Programs by Hydratec Inc. Route 111
Windham N.H. USA 03087
Final Calculations - Hazen -Williams
NP Mechanical Page 6
ESTATES Date 03/28/16
Hyd. Qa Dia. Fitting Pipe Pt Pt
Ref. "C" or Ftng's Pe Pv ******* Notes ******
Point Qt Pf/Ft Eqv. Ln. Total Pf Pn
5
to
6
6
to
7
7
to
8
8
to
9
I JV.V
12.91
0.0302
0.0
1.101
150.0
12.91
0.0303
0.0
1.101
150.0
12.91
0.0302
2.06
1.101
150.0
14.97
0.0398
0.0
14.97
8 -2.06 1.101
to 150.0
12 -2.06-0.0010
9
to
10
10
0.0
-2.06
-11.04
1.101
150.0
-11.04
-0.0226
8.53
1.101
150.0
-2.51
-0.0015
R
1.0
16.667
7.328
N
7.0
8.000
0.0
0.0
24.667
0.746
N
7.0
2.000
8.074
0.0
7.000
0.866
0.0
9.000
0.273
5R
5.0
40.083
9.213
O
5.0
10.000
0.0
0.0
50.083
1.515
2R
2.0
19.250
10.728
O
5.0
7.000
0.0
0.0
26.250
1.044
11.772
2R
2.0
12.667
10.728
0.0
2.000
0.0
0.0
14.667
-0.015
10.713
R
1.0
12.667
11.772
O
5.0
6.000
0.0
0.0
18.667
-0.422
N
7.0
0.583
11.350
0.0
7.000
4.764
0.0
7.583
-0.011
Vel = 4.35
Vel = 4.35
Vel = 5.04
K Factor = 4.36
Vel = 3.72
Vel = 0.85
0.0
-2.51
16.103
K Factor = -0.63
10
-8.53
1.101
R
1.0
4.917
11.350
to
150.0
O
5.0
6.000
0.0
22
-8.53
-0.0141
0.0
10.917
-0.154
Vel =
2.87
22
11.04
1.101
N
7.0
0.583
11.196
to
150.0
0.0
7.000
4.764
21
2.51
0.0015
0.0
7.583
0.011
Vel =
0.85
0.0
2.51
15.971
K Factor = 0.63
22
-11.04
1.101
2R
2.0
14.333
11.196
to
150.0
O
5.0
7.000
0.0
12
-11.04
-0.0226
0.0
21.333
-0.483
Vel =
3.72
12
-2.05
1.101
N
7.0
2.083
10.713
to
150.0
0.0
7.000
0.0
13
-13.09
-0.0310
0.0
9.083
-0.282
Vel =
4.41
13
0.0
1.101
4R
4.0
40.083
10.431
to
150.0
N
7.0
11.000
0.0
B
-13.09
-0.0311
0.0
51.083
-1.588
Vel =
4.41
B
0.0
1.101
N
7.0
2.000
8.843
to
150.0
0.0
7.000
-0.866
C
-13.09
-0.0311
0.0
9.000
-0.280
Vel =
4.41
C
0.0
1.101
R
1.0
4.000
7.697
_
to
150.0
O
5.0
6.000
0.866
14
-13.09
-0.0311
0.0
10.000
-0.311
Vel =
4.41
Computer
Programs by Hydratec Inc. Route 111
Windham N.H. USA 03087
Final Calculations - Hazen -Williams
NP Mechanical
ESTATES
Page 7
Date 03/28/16
Hyd.
Qa
Dia.
Fitting
Pipe
Pt Pt
Ref.
"C"
or
Ftng's
Pe Pv "*""" Notes
Point
Qt
Pf/Ft
Eqv.
Ln.
Total
Pf Pn
14
4.55
1.101
R
1.0
12.667
8.252
to
150.0
O
5.0
6.000
-0.866
2
-8.54
-0.0141
0.0
18.667
-0.263 Vel = 2.88 _
14
to
15
15
to
_16
16
to
1
to
19
19
to
20
20
to
21
19
to
_D5
D5
to
18
18
to
11
9
to
TR
TR
to
BR
0.0
-8.54
4.56 1.101
150.0
-4.56
-0.0044
0.0
1.101
150.0
-4.56
-0.0044
0.0
1.101
150.0
-4.56
-0.0044
0.0
-4.56
0.0
1.101
150.0
0.0
0.0
-2.51
1.101
150.0
-2.51
-0.0015
0.0
1.101
150.0
-2.51
-0.0015
0.0
-2.51
7.123
R 1.0
13.500
8.252
N 7.0
8.000
0.0
0.0
21.500
-0.094
R 1.0
12.750
8.158
N 7.0
8.000
0.0
0.0
20.750
-0.092
R 1.0
4.000
8.066
n
1 000
-0 866
n n
411
N 7.0
0.0
0.0
5.000
9.917
5.000
14.917
13.333
7 nnn
i.uuu
17.000
-0.022
7.178
6.931
0.0
0.0
6.931
K Factor = -3.20
Vel = 1.54
Vel = 1.54
Vel = 1.54
K Factor = -1.70
Vet = 0
-0.030 Vel = 0.85
6.901
9.095
-0.025 Vel = 0.85
15.971 K Factor = -0.63
2.51
1.101
R
1.0
2.083
6.931
150.0
0.0
1.000
0.0
2.51
0.0013
0.0
3.083
0.004
Vel =
0.85
0.0
1.101
N
7.0
2.000
6.935
150.0
0.0
7.000
0.0
2.51
0.0014
0.0
9.000
0.013
Vel =
0.85
0.0
1.101
R
1.0
13.750
6.948
150.0
2P
2.0
10.000
4.331
2.51
0.0015
N
7.0
23.750
0.035
Vel =
0.85
0.0
1.101
N
7.0
10.000
11.314
150.0
0.0
7.000
4.764
2.51
0.0015
0.0
17.000
0.025
Vel =
0.85
0.0
2.51
16.103
K Factor = 0.63
26.00
1.101
N
7.0
5.167
11.772
150.0
0.0
7.000
0.0
26.0
0.1106
0.0
12.167
1.346
Vel =
8.76
0.0
26.00
13.118
K Factor = 7.18
26.00
1.101
2R
2.0
9.000
13.118
150.0
S
9.563
18.562
3.898
26.0
0.1106
N
7.0
27.562
3.047
Vel =
8.76
Computer Programs by Hydratec Inc. Route 111
Windham N.H.
USA 03087
Final Calculations - Hazen -Williams
NP Mechanical
Page 8
ESTATES
Date 03/28/16
Hyd.
Qa
Dia.
Fitting
Pipe
Pt Pt
Ref.
"C"
or
Ftng's
Pe Pv
"""' Notes
Point
Qt
Pf/Ft
Eqv.
Ln.
Total
Pf Pn
` 1.101
O
1.000
20.063
Qa = 5
BR
5.00
5.0
to
150.0
0.0
5.000
0.0
X
31.0
0.1530
0.0
6.000
0.918
Vel = 10.45
X
0.0
1.598
E
5.828
5.000
20.981
to
150.0
0.0
5.828
2.166
EL
31.0
0.0249
0.0
10.828
0.270
Vel = 4.96
EL
0.0
1.598
E
5.828
50.000
23.417
to
150.0
0.0
5.828
0.0
M1
31.0
0.0249
0.0
55.828
1.392
Vel = 4.96
M 1
0.0
0.785
0.0
1.000
24.809
to
150.0
0.0
0.0
10.000
Fixed Loss = 10
M2
31.0
0.7950
0.0
1.000
0.795
Vel = 20.55
M2
to
CM
CM
to
102
102
to
101
101
to
100
100
to
SRC
to
SRC
0.0 0.995
150.0
31.0 0.2506
0.0
7.68
150.0
31.0
0.0
-24.78
7.68
150.0
6.22
0.0
-3.92
7.68
150.0
2.3
0.0
0.0 7.68
150.0
2.3 0.0
0.0
2.30
3.92 7.68
150.0
3.92 0.0
0.0
3.92
T 5.841
50.000
0.0
5.841
0.0
55.841
F 11.278
965.000
T 43.857
55.135
0.0
1020.135
35.604
0.0
13.995
49.599
0.0
0.012
F 11.278
1960.000
49.611
T 43.857
55.135
0.0
0.0
2015.135
0.001
F 11.278
880.000
49.612
T 43.857
55.135
0.0
0.0
935.135
0.0
T 43.857
445.000
49.612
0.0
43.857
3.465
0.0
488.857
0.0
53.077
T 43.857
485.000
49.612
0.0
43.857
3.465
0.0
528.857
0.0
53.077
102 24.78 7.68 T 43.857 130.000 49.611
to 150.0 0.0 43.857 3.465
SRC 24.78 0.0 0.0 173.857 0.001
0.0
24.78 53.077
Vel =
12.79
Vel =
0.21
Vel =
0.04
Vel =
0.02
Vel =
0.02
K Factor = 0.32
Vel =
0.03
K Factor = 0.54
Vel =
0.17
K Factor = 3.40
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
MECHANICAL
NP Mechanical
9225 Stellar Court, Suite A
Corona, CA 92883
951-667-4220
Job Name
ESTATES
Building
PLAN 3
Location
CALC AREA 3
System
Contract
Data File
PLANS CA3 16X16.WXF
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
NP Mechanical Page 1
ESTATES Date 03/28/16
HYDRAULIC DESIGN INFORMATION SHEET
Name - ESTATES Date - 03/28/16
Location - CALC AREA 3
Building - PLAN 3 System No. -
Contractor - NP MECHANICAL Contract No. -
Calculated By - M.G. Drawing No. - 1
Construction: (X) Combustible ( ) Non -Combustible Ceiling Height 10'0"
OCCUPANCY - LIGHT HAZARD
S Type of Calculation: ( )NFPA
13 Residential
( )NFPA 13R (X)NFPA 13D
Y Number of Sprinklers Flowing:
( )l (X)2
( )4 ( )
S ( ) Other
T ( )Specific Ruling
Made by
Date
E
M Listed Flow at Start Point
- 13 Gpm
System Type
Listed Pres. at Start Point
- 7 Psi
(X) Wet ( ) Dry
D MAXIMUM LISTED SPACING 16
x 16
( ) Deluge ( ) PreAction
E Domestic Flow Added
- 5 Gpm
Sprinkler or Nozzle
S Additional Flow Added
- Gpm Make
RELIABLE Model RFC49
I Elevation at Highest Outlet
- Feet Size
7/16 K-Factor 4.9
G Note:
Temperature Rating 165
N
Calculation Gpm Required 26.403
Psi Required:22.6,09,0 AT BR
Summary C -Factor Used:
Overhead 150
Underground 150
W Water Flow Test:
Pump Data:
Tank or Reservoir:
* Datc of Tcst -
Rated Cap.
cap.
T Time of Test -
@ Psi
Elev.
E Static (Psi) - 73
Elev.
R Residual (Psi) - 20
Other
Well
Flow (Gpm) - 1500
Proof Flow Gpm
S Elevation -
P Location:
P
L Source of Information:
Y
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Water Supply Curve C
NP Mechanical
ESTATES
Page 2
Date 03/28/16
City Water Supply: Demand:
Cl - Static Pressure 65.7 D1 - Elevation 13.426
C2 - Residual Pressure: 18 D2 - System Flow : 26.403
C2 - Residual Flow 1500 D2 - System Pressure 56.043
Hose ( Demand) : 5
D3 - System Demand : 31.403
Safety Margin 9.620
150
140
130
P 120
R 110
E 100
S 90
S 80
U 70
—
R 60
E 50 D3
40
30
C2
20
10
200 400 600 800 1000 1200 1400 1600 1800
FLOW (N 11 1.85)
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Fittings Used Summary
NP Mechanical
Page
3
ESTATES
Date
03/28/16
Fitting Legend
Abbrev. Name
1/2
3/4
1
11/4
11/2
2
21/2
3
31/2
4
5
6
8
10
12
14
16 18
20
24
E NFPA 13 90' Standard Elbow
1
2
2
3
4
5
6
7
8
10
12
14
18
22
27
35
40 45
50
61
F NFPA 13 45' Elbow
1
1
1
1
2
2
3
3
3
4
5
7
9
11
13
17
19 21
24
28
N" CPVC 90'EII Harvel-Spears
7
7
8
9
11
12
13
0
0
0
0
0
0
0
0
0 0
0
0
O' CPVC Tee - Branch
3
3
5
6
8
10
12
15
0
0
0
0
0
0
0
0
0 0
0
0
PCPVC 45' Elbow
1
1
1
2
2
2
3
4
0
0
0
0
0
0
0
0
0 0
0
0
R' CPVC Coupling Tee - Run
1
1
1
1
1
1
2
2
0
0
0
0
0
0
0
0
0 0
0
0
S NFPA 13 Swing Check
0
0
5
7
9
11
14
16
19
22
27
32
45
55
65
T NFPA 13 90' Flow thru Tee
3
4
5
6
8
10
12
15
17
20
25
30
35
50
60
71
81 91
101
121
Units Summary
Diameter Units
Inches
Length Units
Feet
Flow Units
US Gallons per Minute
Pressure Units
Pounds per Square Inch
Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters.
Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors
of 120 except as noted with ". The fittings marked with a'' show equivalent lengths values
supplied by manufacturers based on specific pipe diameters and CFactors and they require no
adjustment. All values for fittings not marked with a' will be adjusted in the calculation
for CFactors of other than 120 and diameters other than Sched 40 per NFPA.
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Pressure / Flow Summary - STANDARD
NP Mechanical
Page
4
ESTATES
Date
03/28/16
Node Elevation K-Fact
Pt
Pn
Flow Density
Area
Press
No.
Actual
Actual
Reg.
H1 12.0
13.22
na
H2 12.0
13.22
na
H3 12.0
13.23
na
H4 20.0 4.9
7.04
na
13.0 0.05
256
7.039
H5 20.0 4.9
7.48
na
13.4 0.05
256
7.0
D1 13.0
12.78
na
1 13.0
12.78
na
2 13.0
12.79
na
D2 13.0
12.79
na
3 13.0
12.79
na
D3 13.0
12.8
na
4 13.0
12.8
na
5 13.0
12.81
na
6 13.0
12.83
na
7 11.0
13.7
na
8 11.0
13.74
na
9 11.0
14.19
na
10 11.0
13.26
na
22 11.0
13.21
na
12 11.0
13.58
na
13 11.0
13.58
na
B 11.0
13.63
na
C 13.0
12.77
na
14 11.0
13.64
na
15 11.0
13.65
na
16 11.0
13.65
na
D4 21.0
6.85
na
19 21.0
7.31
na
20 21.0
8.02
na
D5 21.0
7.31
na
18 21.0
7.56
na
17 11.0
12.56
na
TR 11.0
15.58
na
BR 2.0
22.61
na
5.0
X 2.0
23.55
na
EL -3.0
25.9Z3-
na
M1 -3.0
27.42
na
M2 -3.0
38.23
na
CM -3.0
52.56
na
102 -3.0
52.58
na
101 -3.0
52.58
na
100 -3.0
52.58
na
SRC -11.0
56.04
na
The maximum velocity is 20.82 and it occurs in the pipe between nodes M1 and M2
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Final Calculations - Hazen -Williams
NP Mechanical
ESTATES
Page 5
Date 03/28/16
Hyd.
Qa Dia.
Fitting
Pipe
Pt
Pt
Ref.
"C"
or
Ftng's
Pe
Pv '****** Notes ******
Point
Qt Pf/Ft
Eqv. Ln.
Total
Pf
Pn
H 1
0.0
1.101
N 7.0
1.000
13.217
to
150.0
0.0
7.000
-0.433
D1
0.0
0.0
0.0
8.000
0.0
0.0
0.0
12.784
H2
0.0
1.101
N 7.0
1.000
13.221
to
150.0
0.0
7.000
-0.433
D2
0.0
0.0
0.0
8.000
0.0
0.0
0.0
12.788
H3
0.0
1.101
N
7.0
1.000
13.231
to
150.0
0.0
7.000
-0.433
D3
0.0
0.0
0.0
8.000
0.0
0.0
0.0
12.798
H4
13.00
1.101
N
7.0
1.000
7.039
to
150.0
0.0
7.000
-0.433
D4
13.0
0.0306
0.0
8.000
0.245
0.0
_
13.00
6.851
H5
13.40
1.101
N
7.0
1.000
7.481
to
1 rin n
v0.0325
n n
7 nnn
D5
13.4
0.0
8.000
0.260
0.0
13.40
7.308
D1
0.0
1.101
O
5.0
5.250
12.784
to
150.0
0.0
5.000
0.0
1
0.0
0.0
0.0
10.250
0.0
1
0.65
1.101
3R
3.0
9.417
12.784
to
150.0
0.0
3.000
0.0
2
0.65
0.0001
0.0
12.417
0.001
2
1.23
1.101
R
1.0
1.583
12.785
to
150.0
0.0
1.000
0.0
3
1.88
0.0012
0.0
2.583
0.003
0.0
1.88
12.788
D2
0.0
1.101
O
5.0
1.250
12.788
to
150.0
0.0
5.000
0.0
3
0.0
0.0
0.0
6.250
0.0
3
1.88
1.101
R
1.0
10.833
12.788
to
150.0
0.0
1.000
0.0
4
1.88
0.0008
0.0
11.833
0.010
0.0
1.88
12.798
Vel =0
K Factor = 0
Vel = 0
K Factor = 0
Vet = 0
K Factor = 0
K Factor = 4.90
Vel = 4.38
K Factor = 4.97
K Factor = 4.90
Vel = 4.52
K Factor = 4.96
Vel = 0
Vel = 0.22
Vel = 0.63
K Factor = 0.53
Vel = 0
Vel = 0.63
K Factor = 0.53
D3
0.0
1.101 O 5.0 1.250
12.798
to
150.0 0.0 5.000
0.0
4
0.0
0.0 0.0 6.250
0.0 Vel = 0
4
1.88
1.101 N 7.0 2.417
12.798
to
150.0 0.0 7.000
0.0
5
1.88
0.0008 0.0 9.417
0.008 Vel = 0.63
Computer Programs by Hydratec Inc. Route 111
Windham N.H. USA 03087
Final Calculations - Hazen -Williams
NP Mechanical
ESTATES
Page 6
Date 03/28/16
Hyd.
Qa Dia.
Fitting
Pipe
Pt
Pt
Ref.
"C"
or
Ftng's
Pe
Pv "`.. Notes
Point
Qt Pf/Ft
Eqv. Ln.
Total
Pf
Pn
5
0.0
1.101
to
150.0
6
1.88
0.0009
6
0.0
1.101
to
150.0
7
1.88
0.0009
7
to
8
LV
9
8
9
to
10
10
to
22
22
to
21
L12
12
to
13
13
to
B
B
to
C
C
to
14
0.0
1.101
150.0
1.88
0.0008
7.60
1.101
150.0
9.48
0.0171
0.0
9.48
-7.60
1.101
150.0
-7.6
-0.0113
0.0
-7.60
-16.93
1.101
150.0
-16.93
-0.0500
4.49
1.101
150.0
-12.44
-0.0282
0.0
-12.44
-4.49
1.101
150.0
-4.49
-0.0043
-9.48 1.101
150.0
-13.97-0.0349
I JV.V
9.48 0.0171
1.0
16.667
12.806
R
N
7.0
8.000
0.0
0.0
24.667
0.021
N
7.0
2.000
12.827
0.0
7.000
0.866
0.0
9.000
0.008
5R
5.0
40.083
13.701
O
5.0
10.000
0.0
0.0
50.083
0.042
2R
2.0
19.250
13.743
O
5.0
7.000
0.0
0.0
26.250
0.449
14.192
2R
2.0
12.667
13.743
0.0
2.000
0.0
0.0
14.667
-0.166
13.577
R
1.0
12.667
14.192
O
5:0
6.000
0.0
0.0
18.667
-0.933
N
7.0
0.583
13.259
0.0
7.000
4.764
0.0
7.583
-0.214
17.809
R
1.0
4.917
13.259
O
5.0
6.000
0.0
0.0
10.917
-0.047
N
7.0
0.583
13.212
0.0
7.000
4.764
0.0
7.583
-0.265
17.711
2R 2.0 14.333 13.212
O 5.0 7.000 0.0
0.0 21.333 0.365
Vel = 0.63
Vel = 0.63
1\ I QVLVI = G.VG
r\ FCLL:LVI = -L.UO
Vel = 5.71
Vel = 4.19
K Factor = -2.95
Vel = 1.51
Vel = 4.71
K Factor = -3.32
Vel = 3.19
-7.60
1.101
N
7.0
2.083
13.577
150.0
0.0
7.000
0.0
1.88
0.0008
0.0
9.083
0.007
Vel =
0.63
0.0
1.101
4R
4.0
40.083
13.584
150.0
N
7.0
11.000
0.0
1.88
0.0009
0.0
51.083
0.044
Vel =
0.63
0.0
1.101
N
7.0
2.000
13.628
150.0
0.0
7.000
-0.866
1.88
0.0009
0.0
9.000 _
0.008
Vel-=
0.63
0.0
1.101
R
1.0
4.000
12.770
150.0
O
5.0
6.000
0.866
1.88
0.0008
0.0
10.000
0.008
Vel =
0.63
Computer
Programs by Hydratec Inc. Route 111
Windham N.H. USA 03087
Final Calculations - Hazen -Williams
NP Mechanical
Page
7
ESTATES
Date
03/28/16
Hyd.
Qa
Dia.
Fitting
Pipe
Pt Pt
Ref.
"C"
or
Ftng's
Pe Pv
" '"'"
Notes
Point
Qt
Pf/Ft
Eqv.
Ln.
Total
Pf Pn
14
R
1.0
12.667
13.644
-0.66
1.101
to
150.0
O
5.0
6.000
-0.866
2
1.22
0.0004
0.0
18.667
0.007
Vel = 0.41
0.0
1.22
12.785
K Factor =
0.34
14
0.65
1.101
R
1.0
13.500
13.644
to
150.0
N
7.0
8.000
0.0
15
0.65
0.0001
0.0
21.500
0.003
Vel = 0.22
15
0.0
1.101
R
1.0
12.750
13.647
to
150.0
N
7.0
8.000
0.0
16
0.65
0.0001
0.0
20.750
0.002
Vel = 0.22
16
0.0
1.101
R
1.0
4.000
13.649
+�
150 0
0 0
1 000
-n RFR
D4
to
19
19
to
20
20
to
21
to
18
18
to
17
17
I-
to
TR
TR
to
BR
0.65
0.0002
0.0
5.000
0.0
0.65
13.00
1.101
O 5.0
9.917
150.0
0.0
5.000
13.0
0.0307
0.0
14.917
0.97
1.101
N 7.0
13.333
150.0
0.0
7.000
13.97
0.0350
0.0
20.333
0.0
1.101
N 7.0
10.000
i r_n n
0 0
7 000
0.0
13.97
-0.96
1.101
150.0
-0.96
-0.0003
13.40
1.101
150.0
12.44
0.0282
0.0 17.000
R 1.0 2.083
n n 1 nnn
12./b4
6.851
0.0
0.458
7.309
nn
9.Wjb
0.595
17.711
7.309
nn
U.0 /.UUU U.0
0.0 9.000 0.254
Vel = 0.22
K Factor = 0.18
VPI = 4.71
K Factor = 3.32
Vel = 0.32
Vel = 4.19
0.0
1.101
R
1.0
13.750
7.562
150.0
2P
2.0
10.000
4.331
12.44
0.0283
N
7.0
23.750
0.671
Vel = 4.19
0.0
1.101
N
7.0
10.000
12.564
150.0
0.0
7.000
4.764
12.44
0.0283
0.0
17.000
0.481
Vel = 4.19
0.0
12.44
17.809
K Factor = 2.95
26.40
1.101
N
7.0
5.167
14.192
150.0
0.0
7.000
0.0
26.4
0.1138
0.0
12.167
1.384
Vel = 8.90
0.0
26.40
15.576
K Factor = 6.69
26.40
1.101
2R
2.0
9.000
15.576
150.0
S
9.563
18.562
3.898
26.4
0.1137
N
7.0
27.562
3.135
Vel = 8.90
Computer Programs by Hydratec Inc. Route 111
Windham N.H.
USA 03087
Final Calculations - Hazen -Williams
NP Mechanical Page 8
ESTATES Date 03/28/16
Hyd. Qa Dia. Fitting Pipe Pt Pt
Ref. "C" or Ftng's Pe Pv """'* Notes
Point Qt Pf/Ft Eqv. Ln. Total Pf Pn
BR
to
_X
X
to
EL
EL
to
M1
w
_ M2
M2
to
CM
CM
to
102
102
to
101
101
to
100
100
to
SRC
101
5.00
1.101
150.0
31.4
0.1567
0.0
1.598
150.0
31.4
0.0255
0.0
1.598
150.0
31.4
0.0256
0.0
0.785
150.0
31.4
0.8140
0.0
0.995
150.0
31.4
0.2567
0.0
7.68
150.0
31.4
0.0
-25.10
7.68
150.0
6.3
0.0
-3.97
7.68
150.0
2.33
0.0
0.0
7.68
150.0
2.33
0.0
-
0.0
2.33
3.98 7.68
150.0
3.98 0.0
0.0
3.98
O 5.0
1.000
22.609
0.0
5.000
0.0
0.0
6.000
0.940
E 5.828
5.000
23.549
0.0
5.828
2.166
0.0
10.828
0.276
E 5.828
50.000
25.991
0.0
5.828
0.0
0.0
55.828
1.427
0.0
1.000
27.418
0.0
0.0
10.000
0.0
1.000
0.814
T 5.841 50.000 38.232
0.0 5.841 0.0
0.0 55.841 14.332
F 11.278 965.000 52.564
T 43.857 55.135 0.0
0.0 1020.135 0.013
F 11.278
1960.000
52.577
T 43.857
55.135
0.0
0.0
2015.135
0.001
F 11.278
880.000
52.578
T 43.857
55.135
0.0
0.0
935.135
0.0
U.0 40M/ JAb5
0.0 488.857 0.0
56.043
T 43.857 485.000 52.578
0.0 43.857 3.465
0.0 528.857 0.0
56.043
102 25.10 7.68 T 43.857 130.000 52.577
to 150.0 0.0 43.857 3.465
SRC 25.1 0.0 0.0 173.857 0.001
0.0
25.10
56.043
Qa=5
Vel = 10.58
Vel = 5.02
Vel = 5.02
"' Fixed Loss = 10
Vel =
20.82
Vel =
12.96
Vel =
0.22
Vel =
0.04
Vel =
0.02
Vel =
0.02
K Factor = 0.31
Vel = 0.03
K Factor = 0.53
Vel = 0.17
K Factor = 3.35
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
MECHANICAL
NP Mechanical
9225 Stellar Court, Suite A
Corona, CA 92883
951-667-4220
Job Name
: ESTATES
Building
PLAN 3
Location
ALT. CALC AREA 1
System
Contract
Data File
ALT. PLAN3 CA1 20X20.WXF
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
NP Mechanical Page 1
ESTATES Date 03/28/16
HYDRAULIC DESIGN INFORMATION SHEET
Name - ESTATES Date W 03/28/16
Location - ALT. CALC AREA 1
Building - PLAN 3 System No. -
Contractor - NP MECHANICAL Contract No. -
Calculated By - M.G. Drawing No. - 1
Construction: (X) Combustible ) Non -Combustible Ceiling Height 10'0"
OCCUPANCY - LIGHT HAZARD
S
Y
S
T
E
M
D
E
S
I
G
N
Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D
Number of Sprinklers Flowing: (X)1 ( )2 ( )4 ( )
( ) Other
( )Specific Ruling Made by Date
Listed Flow at Start Point - 20 Gpm
Listed Pres. at Start Point - 16.7 Psi
MAXIMUM LISTED SPACING 20 x 20
Domestic Flow Added - 5 Gpm
Additional Flow Added - Gpm
Elevation at Highest Outlet - Feet
Note:
System Type
(X) Wet ( ) Dry
( ) Deluge ( ) PreAction
Sprinkler or Nozzle
Make RELIABLE Model RFC49
Size 7/16 K-Factor 4.9
Temperature Rating 165
Calculation tem Required 20.024. 'Psi Required 27.841 AT BR
Summary C-Factor Used: Overhead 150 Underground 150
W Water Flow Test:
Pump Data:
Tank or Reservoir:
A Date of Test
Ratcd Cap.
Cap.
T Time of Test -
@ Psi
Elev.
E Static (Psi) - 73
Elev.
R Residual (Psi) - 20
Other
Well
Flow (Gpm) - 1500
Proof Flow Gpm
S Elevation
P Location:
P
L Source of Information:
Y
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Water Supply Curve C
NP Mechanical
ESTATES
Page 2
Date 03/28/16
City Water Supply: Demand:
C1 - Static Pressure 65.7 D1 - Elevation 9.961
C2 - Residual Pressure: 18 D2 - System Flow 20.024
C2 - Residual Flow 1500 D2 - System Pressure 55.169
Hose ( Demand) : 5
D3 - System Demand 25.024
Safety Margin 10.507
150
140
130
P 120
R 110
E 100
S 90
S 80
el
U 70
R 60
..�
E 50 D3
40
30
C2
20
10
D1
200 400 600 800 1000 1200 1400 1600 1800
FLOW N^1.85)
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Fittings Used Summary
NP Mechanical
ESTATES
Page
Date
3
03/28/16
Fitting Legend
Abbrev. Name
1/2
3/4
1
11/4
11/2
2
21/2
3
31/2
4
5
6
8
10
12
14
16 18
20
24
E NFPA 13 90' Standard Elbow
1
2
2
3
4
5
6
7
8
10
12
14
18
22
27
35
40 45
50
61
F NFPA 13 45' Elbow
1
1
1
1
2
2
3
3
3
4
5
7
9
11
13
17
19 21
24
28
N- CPVC 90'EII Harvel-Spears
7
7
8
9
11
12
13
0
0
0
0
0
0
0
0
0 0
0
0
O' CPVC Tee - Branch
3
3
5
6
8
10
12
15
0
0
0
0
0
0
0
0
0 0
0
0
P" CPVC 45' Elbow
1
1
1
2
2
2
3
4
0
0
0
0
0
0
0
0
0 0
0
0
RCPVC Coupling Tee - Run
1
1
1
1
1
1
2
2
0
0
0
0
0
0
0
0
0 0
0
0
S NFPA 13 Swing Check
0
0
5
7
9
11
14
16
19
22
27
32
45
55
65
T NFPA 13 90' Flow thru Tee
3
4
5
6
8
10
12
15
17
20
25
30
35
50
60
71
81 91
101
121
Units Summary
Diameter Units
Inches
Length Units
Feet
Flow Units
US Gallons per Minute
Pressure Units
Pounds per Square Inch
Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters.
Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors
of 120 except as noted with '. The fittings marked with a * show equivalent lengths values
supplied by manufacturers based on specific pipe diameters and CFactors and they require no
adjustment. All values for fittings not marked with a * will be adjusted in the calcula=ion
for CFactors of other than 120 and diameters other than Sched 40 per NFPA.
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Pressure / Flow Summary - STANDARD
NP Mechanical Page 4
ESTATES Date 03/28/16
Node
Elevation K-Fact
Pt
Pn
Flow Density
Area Press
No.
Actual
Actual
Req
H1
12.0 4.9
16.7
na
20.02 0.05
400 16.7
H2
12.0
18.37
na
H3
12.0
18.57
na
H4
20.0
17.33
na
H5
20.0
17.34
na
D1
13.0
16.81
na
1
13.0
17.51
na
2
13.0
17.9
na
D2
13.0
17.94
na
3
13.0
17.94
na
D3
13.0
18.14
na
4
13.0
18.14
na
5
13.0
18.29
na
6
13.0
18.7
na
7
11.0
19.71
na
8
11.0
20.53
na
9
11.0
20.92
na
10
11.0
21.18
na
22
11.0
21.06
na
12
11.0
20.53
na
13
11.0
20.34
na
B
11.0
19.24
na
C
13.0
18.18
na
14
11.0
18.83
na
15
11.0
18.62
na
16
11.0
18.43
na
D4
21.0
16.9
na
19
21.0
16.9
na
20
21.0
16.82
na
D5
21.0
16.91
na
18
21.0
16.94
na
17
11.0
21.36
na
11
11.0
21.43
na
TRA
11.0
22.06
na
BR
2.0
27.84
na
5.0
X
2.0
28.46
na
EL
-3.0
30.81
na
M1
-3.0
31.74
na
M2
-3.0
42.28
na
CM
-3.0
51.69
na
102
-3.0
51.7
na
101
-3.0
51.7
na
100
-3.0
51.7
na
SRC
-11.0
55.17
na
The maximum velocity is 16.59 and it occurs in the pipe between nodes M1 and M2
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Final Calculations - Hazen -Williams
NP Mechanical
ESTATES
Page 5
Date 03/28/16
Hyd.
Qa Dia.
Fitting
Pipe
Pt
Pt
Ref.
"C"
or
Ftng's
Pe
Pv "'"""` Notes `ifi
Point
Qt Pf/Ft
Eqv. Ln.
Total
Pf
Pn
H 1
20.02 1.101
N 7.0
1.000
16.700
to
150.0
0.0
7.000
-0.433
D1
20.02 0.0681
0.0
8.000
0.545
H2 0.0 1.101 N 7.0 1.000 18.375
to 150.0 0.0 7.000 -0.433
D2 0.0 0.0 0.0 8.000 0.0 Vel = 0
0.0
0.0 17.942 K Factor = 0
V Fartnr - d QO
K Factor = 4.88
H3
0.0
1.101
N 7.0
1.000
18.569
to
150.0
0.0
7.000
-0.433
D3
0.0
0.0
0.0
8.000
0.0
0.0
0.0
18.136
H4
0.0
1.101
N 7.0
1.000
17.332
to
150.0
0.0
7.000
-0.433
D4
0.0
0.0
0.0
8.000
0.0
0.0
0.0
16.899
H5
0.0
1.101
N 7.0
1.000
17.343
to
150.0
no
7 000
-0.433
D5
0.0
0.0
0.0
8.000
0.0
D1
20.02
1.101
O
5.0
5.250
16.812
to
150.0
0.0
5.000
0.0
1
20.02
0.0682
0.0
10.250
0.699
1
-6.89
1.101
3 R
3.0
9.417
17.511
to
150.0
0.0
3.000
0.0
2
13.13
0.0312
0.0
12.417
0.388
2
-3.86
1.101
R
1.0
1.583
17.899
to
150.0
0.0
1.000
0.0
3
9.27
0.0166
0.0
2.583
0.043
0.0
9.27
17.942
D2
0.0
1.101
O
5.0
1.250
17.942
to
150.0
0.0
5.000
0.0
0.0
0.0
0.0
6.250
0.0
_3
3
9.27
1.101
R
1.0
10.833
17.942
to
150.0
0.0
1.000
0.0
4
9.27
0.0164
0.0
11.833
0.194
0.0
9.27
18.136
Vel = 0
Vel = 0
K Factor = 0
Vel = 0
K Factor = 0
Vel = 6.75
Vel = 4.42
Vel = 3.12
K Factor = 2.19
Vel = 0
Vel = 3.12
K Factor = 2.18
4 0.0 0.0 0.0 6.250 0.0 Vel = 0
4 9.27 1.101 N 7.0 2.417 18.136
to 150.0 0.0 7.000 0.0
5 9.27 0.0164 0.0 9.417 0.154 Vel = 3.12
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Final Calculations - Hazen -Williams
NP Mechanical Page 6
ESTATES Date 03/28/16
Hyd. Qa Dia. Fitting Pipe Pt Pt
Ref. "C" or Ftng's Pe Pv *"* `"' Notes
Point Qt Pf/Ft Eqv. Ln. Total Pf Pn
5
to
6
6
to
7
7
to
8
8
to
9
8
to
12
9
to
10
10
to
11
10
to
22
22
to
21
22
to
12
12
13
to
B
B
to
C
C
to
14
0.0
1.101
R
1.0
16.667
18.290
150.0
N
7.0
8.000
0.0
9.27
0.0164
0.0
24.667
0.405
0.0
1.101
N
7.0
2.000
18.695
150.0
0.0
7.000
0.866
9.27
0.0164
0.0
9.000
0.148
0.0
1.101
5R
5.0
40.083
19.709
150.0
O
5.0
10.000
0.0
9.27
0.0164
0.0
50.083
0.823
-0.82
1.101
2R
2.0
19.250
20.532
150.0
N
7.0
9.000
0.0
8.45
0.0138
0.0
28.250
0.390
0.0
8.45
20.922
0.82 1.101
0.82
0.0
0.82
8.45
8.45
150.0
0.0001
1.101
150.0
0.0138
7.41
1.101
150.0
15.86
0.0442
0.0
15.86
-7.41
1.101
150.0
-7.41
-0.0108
11.58
1.101
150.0
4.17
0.0037
0.0
4.17
-11.57
1.101
150.0
2R 2.0 12.667 20.532
0.0 2.000 0.0
0.0 14.667 0.002
20.534
R 1.0
O 5.0
0.0
12.667
6.000
18.667
20.922
0.0
0.258
O 5.0
0.583
21.180
0.0
5.000
0.0
0.0
5.583
0.247
21.427
R 1.0
4.917
21.180
O 5.0
6.000
0.0
0.0
10.917
-0.118
N 7.0
0.583
21.062
0.0
7.000
4.764
0.0
7.583
0.028
Vel = 3.12
Vel = 3.12
Vel = 3.12
Vel = 2.85
K Factor = 1.85
Vel = 0.28
K Factor = 0.18
Vel = 2.85
Vel = 5.34
K Factor = 3.43
Vel = 2.50
Vel = 1.41
25.854 K Factor = 0.82
2R 2.0 14.333 21.062
O 5.0 7.000 0.0
-11.57
-0.0248
0.0
21.333
-0.528
Vel =
3.90
0.82
1.101
N
7.0
2.083
20.534
150.0
0.0
7.000
0.0
-10.75
-0.0216
0.0
9.083
-0.196
Vel =
3.62
0.0
1.101
4R
4.0
40.083
20.338
150.0
N
7.0
11.000
0.0
-10.75
-0.0216
0.0
51.083
-1.102
Vel =
3.62
0.0
1.101
N
7.0
2.000
19.236
150.0
0.0
7.000
-0.866
-10.75
-0.0216
0.0
9.000
-0.194
Vel =
3.62
0.0
1.101
R
1.0
4.000
18.176
150.0
O
5.0
6.000
0.866
-10.75
-0.0216
0.0
10.000
-0.216
Vel =
3.62
Computer Programs by Hydratec Inc. Route 111
Windham N.H. USA 03087
Final Calculations - Hazen -Williams
NP Mechanical
ESTATES
Page 7
Date 03/28/16
Hyd.
Qa Dia.
Fitting
Pipe
Pt
Pt
Ref.
"C"
or
Ftng's
Pe
Pv """' Notes ******
Point
Qt Pf/Ft
Eqv. Ln.
Total
Pf
Pn
14 6.89 1.101
to 150.0
2 -3.86-0.0033
0.0
-3.86
14 -6.89 1.101
to 150.0
15 -6.89-0.0095
15 0.0 1.101
to 150.0
16 -6.89-0.0095
16
0.0
1.101
to
150.0
1
-6.89
-0.0096
0.0
-6.89
D4
0.0
1.101
to
150.0
19
0.0
0.0
19
-4.17
1.101
to
150.0
20
-4.17
-n.nn.q7
20
0.0
1.101
to
150.0
21
-4.17
-0.0038
0.0
-4.17
19 4.17 1.101
to 150.0
D5 4.17 0.0036
D5 0.0 1.101
to 150.0
18 4.17 0.0038
R 1.0
12.667
18.826
O 5.0
6.000
-0.866
0.0
18.667
-0.061
17.899
R 1.0
13.500
18.826
N 7.0
8.000
0.0
0.0
21.500
-0.204
R 1.0
12.750
18.622
N 7.0
8.000
0.0
0.0
20.750
-0.197
R 1.0
4.000
18.425
0.0
1.000
-0.866
0.0
5.000
-0.048
17.511
O 5.0
9.917
16.899
0.0
5.000
0.0
0.0
14.917
0.0
N 7.0
13.333
16.899
0.0
7.000
0.0
n n
PO
-n.rns
N 7.0
10.000
16.823
0.0
7.000
9.095
0.0
17.000
-0.064
25.854
R 1.0
2.083
16.899
0.0
1.000
0.0
0.0
3.083
0.011
N 7.0
2.000
16.910
0.0
7.000
0.0
0.0
9.000
0.034
Vel = 1.30
K Factor = -0.91
Vel = 2.32
Vel = 2.32
Vel = 2.32
K Factor = -1.65
Vel = 0
Vel = 1.41
Vel = 1.41
K Factor = -0.82
Vel = 1.41
Vel = 1.41
18
0.0
1.101
R
1.0
13.750
16.944
to
150.0
2P
2.0
10.000
4.331
17
4.17
0.0037
N
7.0
23.750
0.089
Vel =
1.41
17
0.0
1.101
N
7.0
10.000
21.364
to
150.0
0.0
7.000
0.0
11
4.17
0.0037
0.0
17.000
0.063
Vel =
1.41
11
15.85
1.101
N
7.0
2.333
21.427
to
150.0
0.0
7.000
0.0
TRA
20.02
0.0683
0.0
9.333
0.637
Vel =
6.75
0.0
20.02
22.064
K Factor = 4.26
TRA
20.02
1.101
2R
2.0
9.000
22.064
to
150.0
S
9.563
18.562
3.898
BR
20.02
0.0682
N
7.0
27.562
1.879
Vel =
6.75
BR
5.00
1.101
O
5.0
1.000
27.841
Qa =
5
to
150.0
0.0
5.000
0.0
X
25.02
0.1030
0.0
6.000
0.618
Vel =
8.43
Computer Programs by Hydratec Inc. Route 111
Windham N.H.
USA 03087
Final Calculations - Hazen -Williams
NP Mechanical Page 8
ESTATES Date 03/28/16
Hyd. Qa Dia. Fitting Pipe Pt Pt
Ref. "C" or Ftng's Pe Pv "`' Notes
Point Qt Pf/Ft Eqv. Ln. Total Pf Pn
X
0.0
1.598
to
150.0
EL
25.02
0.0167
EL
0.0
1.598
to
150.0
M 1
25.02
0.0168
M 1
0.0
0.785
to
150.0
M2
25.02
0.5340
M2
0.0
0.995
to
150.0
CM
25.02
0.1686
CM
0.0
7.68
to
150.0
102
25.02
0.0
102
-20.00
7.68
to
150.0
101
5.02
0.0
101
-3.17
7.68
to
150.0
100
1.85
0.0
100 0.0 7.68
to 150.0
SRC 1.85 0.0
0.0
1.85
101
3.17
7.68
to
150.0
SRC
3.17
0.0
0.0
3.17
102
20.00
7.68
to
150.0
SRC
20.0
0.0
E 5.828
5.000
28.459
0.0
5.828
2.166
0.0
10.828
0.181
E 5.828
50.000
30.806
0.0
5.828
0.0
0.0
55.828
0.938
0.0
1.000
31.744
0.0
0.0
10.000
0.0
1.000
0.534
T 5.841
50.000
42.278
0.0
5.841
0.0
0.0
55.841
9.417
F 11.278
965.000
51.695
T 43.857
55.135
0.0
0.0
1020.135
0.008
F 11.278
1960.000
51.703
T 43.857
55.135
0.0
0.0
2015.135
0.001
F 11.278
880.000
51.704
T 43.857
55.135
0.0
0.0
935.135
0.0
T 43.857
445.000
51.704
0.0
43.857
3.465
0.0
488.857
0.0
55.169
T 43.857
485.000
51.704
0.0
43.857
3.465
0.0
528.857
0.0
55.169
T 43.857
130.000
51.703
0.0
43.857
3.465
0.0
173.857 _
0.001
55.169
Vel = 4.00
Vel = 4.00
" Fixed Loss = 10
Vel =
16.59
Vel =
10.32
Vel =
0.17
Vel =
0.03
Vel =
0.01
Vel =
0.01
K Factor = 0.25
Vel =
0.02
K Factor = 0.43
Vel = 0.14
K Factor = 2.69
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
MECHANICAL
NP Mechanical
9225 Stellar Court, Suite A
Corona, CA 92883
951-667-4220
Job Name
: ESTATES
Building
: PLAN 3
Location
ALT. CALC AREA 2
System
Contract
Data File
ALT. PLAN3 CA2 16X16.WXF
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
NP Mechanical
ESTATES
Page 1
Date 03/28/16
HYDRAULIC DESIGN INFORMATION SHEET
Name - ESTATES Date - 03/28/16
Location - ALT. CALC AREA 2
Building - PLAN 3 System No. -
Contractor - NP MECHANICAL Contract No. -
Calculated By - M.G. Drawing No. - 1
Construction: (X) Combustible { ) Non -Combustible Ceiling Height 10'0"
OCCUPANCY - LIGHT HAZARD
S
Y
S
T
E
M
D
E
S
I
G
N
Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D
Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( )
( ) Other
( )Specific Ruling Made by Date
Listed Flow at Start Point
- 13
Gpm
Listed Pres. at Start Point
- 7
Psi
MAXIMUM LISTED SPACING 16
x 16
Domestic Flow Added
- 5
Gpm
Additional Flow Added
-
Gpm
Elevation at Highest Outlet
-
Feet
Note:
System Type
(X) Wet ( ) Dry
( ) Deluge ( ) PreAction
Sprinkler or Nozzle
Make RELIABLE Model RFC49
Size 7/16 K-Factor 4.9
Temperature Rating 165
Calculation I'Gpm Required 26.001 Psi Required 20.14'8 AT BR
Summary C-Factor Used: Overhead 150 Underground 150
W Water Flow Test: Pump Data: Tank or Reservoir:
-A Date -of -Test — -Ratcd Cap-. -dap
T Time of Test - @ Psi Elev.
E Static (Psi) - 73 Elev.
R Residual (Psi) - 20 Other Well
Flow (Gpm) - 1500 Proof Flow Gpm
S Elevation -
P Location:
P
L Source of Information:
Y
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Water Supply Curve C
NP Mechanical
ESTATES
Page 2
Date 03/28/16
City Water Suppiy: Demand:
Cl - Static Pressure 65.7 D1 - Elevation 9.961
C2 - Residual Pressure. 18 D2 - System Flow : 26.001
C2 - Residual Flow 1500 D2 - System Pressure : 53.163
Hose ( Demand) : 5
D3 - System Demand : 31.001
Safety Margin 12.501
150
140
130
P 120
R 110
E 100
S 90
S 80
u 70
--
R 60
D2
E 50
D3
40
30
C2
20
10
LL....
L
........
.........
. . . . . . .
. . . . . . . . .
200 400 600 800 1000 1200 1400 1600 1800
FLOW (N 1 1.85)
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Fittings Used Summary
NP Mechanical
Page
3
ESTATES
Date
03/28/16
Fitting Legend
Abbrev. Name
1/2
3/4
1
1'/4
11/2
2
21/2
3
31/2
4
5
6
8
10
12
14
16 18
20
24
E NFPA 13 90' Standard Elbow
1
2
2
3
4
5
6
7
8
10
12
14
18
22
27
35
40 45
50
61
F NFPA 13 45' Elbow
1
1
1
1
2
2
3
3
3
4
5
7
9
11
13
17
19 21
24
28
NCPVC 90'EII Harvel-Spears
7
7
8
9
11
12
13
0
0
0
0
0
0
0
0
0 0
0
0
O' CPVC Tee - Branch
3
3
5
6
8
10
12
15
0
0
0
0
0
0
0
0
0 0
0
0
P' CPVC 45' Elbow
1
1
1
2
2
2
3
4
0
0
0
0
0
0
0
0
0 0
0
0
R" CPVC Coupling Tee - Run
1
1
1
1
1
1
2
2
0
0
0
0
0
0
0
0
0 0
0
0
S NFPA 13 Swing Check
0
0
5
7
9
11
14
16
19
22
27
32
45
55
65
T NFPA 13 90' Flow thru Tee
3
4
5
6
8
10
12
15
17
20
25
30
35
50
60
71
81 91
101
121
Units Summary
Diameter Units
Inches
Length Units
Feet
Flow Units
US Gallons per Minute
Pressure Units
Pounds per Square Inch
Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters.
Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors
of 120 except as noted with *. The fittings marked with a' show equivalent lengths values
supplied by manufacturers based on specific pipe diameters and CFactors and they require no
adjustment. All values for fittings not marked with a " will be adjusted in the calculation
for CFactors of other than 120 and diameters other than Sched 40 per NFPA.
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Pressure / Flow Summary - STANDARD
NP Mechanical
ESTATES
Page 4
Date 03/28/16
Node
Elevation K-Fact
Pt
Pn
No.
Actual
1-11
12.0
7.61
na
H2
12.0 4.9
7.0.1
na
H3
12.0 4.9
7.04
na
H4
20.0
7.95
na
H5
20.0
7.97
na
D1
13.0
7.18
na
1
13.0
7.18
na
2
13.0
7.12
na
D2
13.0
6.85
na
3
13.0
7.04
na
D3
13.0
6.85
na
4
13.0
7.04
na
5
13.0
7.33
na
6
13.0
8.07
na
7
11.0
9.21
na
8
11.0
10.71
na
9
11.0
11.35
na
10
11.0
11.77
na
22
11.0
11.58
na
12
11.0
10.73
na
13
11.0
10.44
na
B
11.0
8.85
na
C
13.0
7.7
na
14
11.0
8.25
na
15
11.0
8.16
na
16
11.0
8.07
na
D4
21.0
7.52
na
19
21.0
7.52
na
20
21.0
7.4
na
D5
21.0
7.54
na
18
21.0
7.59
na
17
11.0
12.07
na
11
11.0
12.17
na
TRA
11.0
13.2
na
BR
2.0
20.15
na
X
2.0
21.07
na
EL
-3.0
5-5
na
M1
-3.0
24.89
na
M2
-3.0
35.69
na
CM
-3.0
49.68
na
102
-3.0
49.7
na
101
-3.0
49.7
na
100
-3.0
49.7
na
SRC
-11.0
53.16
na
Flow Density
Actual
13.0
13.0
5.0
The maximum velocity is 20.55 and it occurs in the pipe between nodes M1 and M2
0.05
0.05
Area Press
Req.
256 7.039
256 7.039
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Final Calculations - Hazen -Williams
NP Mechanical
Page 5
ESTATES
Date 03/28/16
Hyd.
Qa
Dia.
Fitting
Pipe
Pt Pt
Ref.
"C"
or
Ftng's
Pe Pv
"" "" Notes
Point
Qt
Pf/Ft
Eqv.
Ln.
Total
Pf Pn
H 1
0.0
1.101
N
7.0
1.000
7.612
to
150.0
0.0
7.000
-0.433
_ D1
0.0
0.0
0.0
8.000
0.0
Vel = 0
0.0
0.0
7.179
K Factor = 0
H2
13.00
1.101
N
7.0
1.000
7.039
K Factor = 4.90
to
150.0
0.0
7.000
-0.433
D2
13.0
0.0306
0.0
8.000
0.245
Vel = 4.38
0.0
13.00
6.851
K Factor = 4.97
H3
13.00
1.101
N
7.0
1.000
7.039
K Factor = 4.90
to
150.0
0.0
7.000
-0.433
D3
13.0
0.0306
0.0
8.000
0.245
Vel = 4.38
0.0
13.00
6.851
K Factor = 4.97
to
D4
H5
to
D5
D1
to
1
1
to
2
2
to
3
D2
to
3
3
to
4
D3
to
4
4
to
5
0.0
1.101
N
7.0
150.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
1.101
N
7.0
15nn
nn
0.0
0.0
0.0
0.0
0.0
0.0
1.101
O
5.0
150.0
0.0
0.0
0.0
0.0
-4.57
1.101
3R
3.0
150.0
0.0
-4.57
-0.0044
0.0
-8.56
1.101
R
1.0
150.0
0.0
-13.13
-0.0314
0.0
0.0
-13.13
13.00
1.101
O
5.0
150.0
0.0
13.0
0.0307
0.0
1.000
7.953
7.000
-0.433
8.000
0.0
7.520
1.000
7.972
7 000
-0.433
8.000
0.0
S.000
10.250
9.417
Q nnn
I .uuu
2.583
1.250
5.000
6.250
7.539
1
411
7.179
0.0
-0.055
Vel = 0
K Factor = 0
Vel = 0
K Factor = 0
Vel = 0
Vel = 1.54
7.124
0.0
-0.081 Vel = 4.42
7.043 K Factor = -4.95
6.851
0.0
0.192 Vel = 4.38
-13.13
1.101
R 1.0
10.833
7.043
150.0
0.0
1.000
0.0
-0.13
0.0
0.0
11.833
0.0
Vel = 0.04
0.0
-0.13
7.043
K Factor = -0.05
13.00
1.101
O 5.0
1.250
6.851
150.0
0.0
5.000
0.0
13.0
0.0307
0.0
6.250
0.192
Vel = 4.38
-0.13
1.101
N 7.0
2.417
7.043
150.0
0.0
7.000
0.0
12.87
0.0301
0.0
9.417
0.283
Vel = 4.34
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Final Calculations - Hazen -Williams
NP Mechanical Page 6
ESTATES Date 03/28/16
Hyd. Qa Dia. Fitting Pipe Pt Pt
Ref. "C" or Ftng's Pe Pv *' ``* ' Notes ******
Point Qt Pf/Ft Eqv. Ln. Total Pf Pn
5
to
6
6
to
7
7
to
8
8
to
9
8
to
12
9
to
10
10
to
11
0.0
1.101
150.0
12.87
0.0301
0.0
1.101
150.0
12.87
0.0301
0.0
1.101
150.0
12.87
0.0301
-1.87
1.101
150.0
11.0
0.0225
0.0
11.00
1.87
1.101
150.0
1.87
0.0009
0.0
1.87
11.00 1.101
150.0
11.0 0.0225
9.59 1.101
150.0
20.59 0.0718
0.0
20.59
10
-9.59
1.101
to
150.0
22
-9.59
-0.0175
22
15.00
1.101
to
150.0
21
5.41
0.0061
0.0
5.41
22
-15.00
1.101
to
150.0
12
-15.0
-0.0399
12
to
13
13
to
B
B
to
C
C
to
14
R
1.0
16.667
7.326
N
7.0
8.000
0.0
0.0
24.667
0.743
N
7.0
2.000
8.069
0.0
7.000
0.866
0.0
9.000
0.271
5R
5.0
40.083
9.206
O
5.0
10.000
0.0
0.0
50.083
1.508
2R 2.0 19.250 10.714
N 7.0 9.000 0.0
0.0 28.250 0.636
11.350
2R 2.0 12.667 10.714
0.0 2.000 0.0
0.0 14.667 0.013
10.727
R 1.0
12.667
11.350
O 5.0
6.000
0.0
0.0
18.667
0.420
O 5.0
0.583
11.770
0.0
5.000
0.0
0.0
5.583
0.401
12.171
R
1.0
4.917
11.770
O
5.0
6.000
0.0
0.0
10.917
-0.191
N
7.0
0.583
11.579
0.0
7.000
4.764
0.0
7.583
0.046
16.389
2R
2.0
14.333
11.579
O
5.0
7.000
0.0
0.0
21.333
-0.852
Vel = 4.34
Vel = 4.34
Vel = 4.34
Vel = 3.71
K Factor = 3.27
Vel = 0.63
K Factor = 0.57
Vel = 3.71
Vel = 6.94
K Factor = 5.90
Vel = 3.23
Vel = 1.82
K Factor = 1.34
Vel = 5.05
1.87
1.101
N
7.0
2.083
10.727
150.0
0.0
7.000
0.0
-13.13
-0.0313
0.0
9.083
-0.284
Vel =
4.42
0.0
1.101
4R
4.0
40.083
10.443
150.0
N
7.0
11.000
0.0
-13.13
-0.0312
0.0
51.083
-1.595
Vel =
4.42
0.0
1.101
N
7.0
2.000
8.848
150.0
0.0
7.000
-0.866
-13.13
-0.0313
0.0
9.000
-0.282
Vel =
4.42
0.0
1.101
R
1.0
4.000
7.700
150.0
O
5.0
6.000
0.866
-13.13
-0.0312
0.0
10.000
-0.312
Vel =
4.42
Computer Programs by Hydratec
Inc. Route 111
Windham N.H.
USA 03087
Final Calculations - Hazen -Williams
NP Mechanical
Page 7
ESTATES
Date 03/28/16
Hyd.
Qa
Dia.
Fitting
Pipe
Pt Pt
Ref.
"C"
or
Ftng's
Pe Pv
*'*""** Notes
Point
Qt
Pf/Ft
Eqv.
Ln.
Total
Pf Pn
14
1.101
1.0
12.667
8.254
R
4.57
to
150.0
O
5.0
6.000
-0.866
_ 2
-8.56
-0.0141
0.0
18.667
-0.264
Vel = 2.88
0.0
-8.56
7.124
K Factor = -3.21
14
-4.57
1.101
R
1.0
13.500
8.254
to
150.0
N
7.0
8.000
0.0
15
-4.57
-0.0044
0.0
21.500
-0.095
Vel = 1.54
15
0.0
1.101
R
1.0
12.750
8.159
to
1500
N
7.0
8.000
0.0
16
-4.57
-0.0044
0.0
20.750
16
0.0
1.101
R
1.0
4.000
to
150.0
0.0
1.000
1
-4.57
-0.0044
0.0
5.000
0.0
-4.57
D4
0.0
1.101
O
5.0
9.917
to
150.0
0.0
5.000
19
0.0
0.0
0.0
14.917
19
-5.41
1.101
N
7.0
13.333
to
150.0
0.0
7.000
20
-5.41
-n.nnFn
n,n
20.333
20
0.0
1.101
N
7.0
10.000
to
150.0
0.0
7.000
21
-5.41
-0.0061
0.0
17.000
0.0
-5.41
to
18
18
to
17
17
to
to
TRA
TRA
to
BR
I
5.41
1.101
R
1.0
2.083
150.0
0.0
1.000
5.41
0.0062
0.0
3.083
0.0
1.101
N
7.0
2.000
150.0
0.0
7.000
5.41
0.0060
0.0
9.000
0.0
1.101
R
1.0
13.750
150.0
2P
2.0
10.000
5.41
0.0061
N
7.0
23.750
0.0
1.101
N
7.0
10.000
150.0
0.0
7.000
5.41
0.0061
0.0
17.000
20.59
1.101
N
7.0
2.333
150.0
0.0
7.000
ffel Wifff
7.179
7.520
0.0
0.0
7.520
0.0
0.123
7.397
9.095
-0.103
16.389
7.520
0.0
0.019
7.539
0.0
0.054
7.593
4.331
0.144
12.068
0.0
0.103
12.171
0.0
Vel = 1.54
Vel = 1.54
K Factor = -1.71
Vel = 0
Vel = 1.82
Vel = 1.82
K Factor = -1.34
Vel = 1.82
Vel = 1.82
Vel = 1.82
Vel = 1.82
26.0
0.1106
0.0
9.333
1.032
Vel = 8.76
0.0
26.00
13.203
K Factor = 7.16
26.00
1.101
2R
2.0
9.000
13.203
150.0
S
9.563
18.562
3.898
26.0
0.1106
N
7.0
27.562
3.047
Vel = 8.76
5.00
1.101
O
5.0
1.000
20.148
Qa = 5
150.0
0.0
5.000
0.0
31.0
0.1530
0.0
6.000
0.918
Vel = 10.45
Computer Programs by Hydratec Inc. Route 111
Windham N.H.
USA 03087
Final Calculations - Hazen -Williams
NP Mechanical Page 8
ESTATES Date 03/28/16
Hyd. Qa Dia. Fitting Pipe Pt Pt
Ref. "C" or Ftng's Pe Pv ******* Notes ******
Point Qt Pf/Ft Eqv. Ln. Total Pf Pn
X 0.0 1.598 E 5.828 5.000 21.066
to 150.0 0.0 5.828 2.166
EL 31.0 0.0249 0.0 10.828 0.270
EL
0.0
1.598
to
150.0
M 1
31.0
0.0250
M1
0.0
0.785
to
150.0
M2
31.0
0.7950
M2
0.0
0.995
to
150.0
CM
31.0
0.2506
CM
0.0
7.68
to
150.0
102
31.0
0.0
102
to
101
101
to
100
100
101
to
SRC
-24.78 7.68
150.0
6.22 0.0
-3.92 7.68
150.0
2.3 0.0
0.0 7.68
150.0
2.3 0.0-
0.0
2.30
3.92 7.68
150.0
3.92 0.0
0.0
3.92
102 24.78 7.68
to 150.0
SRC 24.78 0.0
0.0
24.78
E 5.828
0.0
0.0
50.000
5.828
55.828
23.502
0.0
1.393
0.0
1.000
24.895
0.0
0.0
10.000
0.0
1.000
0.795
T 5.841
50.000
35.690
0.0
5.841
0.0
0.0
55.841
13.994
F 11.278
965.000
49.684
T 43.857
55.135
0.0
0.0
1020.135
0.012
F 11.278
1960.000
49.696
T 43.857
55.135
0.0
0.0
2015.135
0.002
F 11.278
880.000
49.698
T 43.857
55.135
0.0
0.0
935.135
0.0
T 43.857
445.000
49.698
0.0
43.857
3.465
0.0
488.857
0.0
53.163
T 43.857
485.000
49.698
0.0
43.857
3.465
0.0
528.857
0.0
53.163
T 43.857
130.000
49.696
0.0
43.857
3.465
0.0
173.857
0.002
53.163
Vel = 4.96
Vel = 4.96
* * Fixed Loss = 10
Vel = 20.55
Vel = 12.79
Vel = 0.21
Vel = 0.04
Vel = 0.02
Vel = 0.02
K Factor = 0.32
Vel = 0.03
K Factor = 0.54
Vel = 0.17
K Factor = 3.40
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
MECHANICAL
NP Mechanical
9225 Stellar Court, Suite A
Corona, CA 92883
951-667-4220
Job Name
ESTATES
Building
PLAN 3
Location
ALT. CALC AREA 3
System
Contract
Data File
ALT. PLANS CA3 16X16.WXF
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
NP Mechanical
ESTATES
Page 1
Date 03/28/16
HYDRAULIC DESIGN INFORMATION SHEET
Name - ESTATES Date - 03/28/16
Location - ALT. CALC AREA 3
Building - PLAN 3
Contractor - NP MECHANICAL
Calculated By - M.G.
Construction: (X) Combustible
OCCUPANCY - LIGHT HAZARD
S
Y
S
T
E
M
D
E
S
I
G
N
System No. -
Contract No. -
Drawing No. - 1
( ) Non -Combustible Ceiling Height 10'0"
Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R
Number of Sprinklers Flowing: ( )l (X)2 ( )4 ( )
( )Other
( )Specific Ruling Made by
Listed Flow at Start Point - 13 Gpm
Listed Pres. at Start Point - 7 Psi
MAXIMUM LISTED SPACING 16 x 16
Domestic Flow Added - 5 Gpm
Additional Flow Added - Gpm
Elevation at Highest Outlet - Feet
Note:
(X)NFPA 13D
Date
System Type
(X) Wet ( ) Dry
( ) Deluge ( ) PreAction
Sprinkler or Nozzle
Make RELIABLE Model RFC49
Size 7/16 K-Factor 4.9
Temperature Rating 165
Calculation Gpm Required 26.404 Psi Required 21.41.0 AT BR
Summary C-Factor Used: Overhead 150 Underground 150
W Water Flow Test:
--A:-- -DaLe of Test --
T Time of Test -
E Static (Psi) - 73
R Residual (Psi) - 20
Flow (Gpm) - 1500
S Elevation -
P Location:
P
L Source of Information:
Y
Pump Data: Tank or Reservoir:
gated Cap.---C-ap � -
@ Psi Elev.
Elev.
Other Well
Proof Flow Gpm
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Water Supply Curve C
NIP Mechanical
ESTATES
Page 2
Date 03/28/16
City Water Supply: Demand:
Cl - Static Pressure 65.7 D1 - Elevation 13.426
C2 - Residual Pressure: 18 D2 - System Flow 26.404
C2 - Residual Flow 1500 D2 - System Pressure 54.845
Hose ( Demand ) 5
D3 - System Demand 31.404
Safety Margin 10.818
150
140
130
P 120
R 110
E 100
S 90
S 80
U 70
R 60
E 50 ❑3
40
30
C2
20
10
200 400 600 800 1000 1200 1400 1600 1800
FLOW (N^1.85)
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Fittings Used Summary
NP Mechanical
ESTATES
Page
Date
3
03/28/16
Fitting Legend
Abbrev. Name
1/2 3/4 1 1-: •1
11/2
2
21/2
3
31/2
4
5
6
8
10
12
14
16 18
20
24
E NFPA 13 90' Standard Elbow
1 2 2 3
4
5
6
7
8
10
12
14
18
22
27
35
40 45
50
61
F NFPA 13 45' Elbow
1 1 1 1
2
2
3
3
3
4
5
7
9
11
13
17
19 21
24
28
NCPVC 90'EII Harvel-Spears
7 7 8
9
11
12
13
0
0
0
0
0
0
0
0
0 0
0
0
O' CPVC Tee - Branch
3 3 5 6
8
10
12
15
0
0
0
0
0
0
0
0
0 0
0
0
P' CPVC 45' Elbow
1 1 1 2
2
2
3
4
0
0
0
0
0
0
0
0
0 0
0
0
R' CPVC Coupling Tee - Run
1 1 1 1
1
1
2
2
0
0
0
0
0
0
0
0
0 0
0
0
S NFPA 13 Swing Check
0 0 5 7
9
11
14
16
19
22
27
32
45
55
65
T NFPA 13 90' Flow thru Tee
3 4 5 6
8
10
12
15
17
20
25
30
35
50
60
71
81 91
101
121
Units Summary
Diameter Units
Inches
Length Units
Feet
Flow Units
US Gallons per Minute
Pressure Units
Pounds per Square Inch
Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters.
Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors
of 120 except as noted with *. The fittings marked with a * show equivalent lengths values
supplied by manufacturers based on specific pipe diameters and CFactors and they require no
adjustment. All values for fittings not marked with a " will be adjusted in the calculation
for CFactors of other than 120 and diameters other than Sched 40 per NFPA.
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Pressure / Flow Summary - STANDARD
NP Mechanical
ESTATES
Node
Elevation K-Fact
No.
H 1
12.0
H2
12.0
H3
12.0
H4
20.0 4.9
H5
20.0 4.9
D 1
13.0
1
13.0
2
13.0
D2
13.0
3
13.0
D3
13.0
4
13.0
5
13.0
6
13.0
7
11.0
8
11.0
9
11.0
10
11.0
22
11.0
12
11.0
13
11.0
B
11.0
C
13.0
14
11.0
15
11.0
16
11.0
D4
21.0
19
21.0
20
21.0
D5
21.0
18
21.0
17
11.0
11
11.0
TRA
11.0
BR
2.0
X
2.0
EL
-3.0
M 1
-3.0
M2
-3.0
CM
-3.0
102
-3.0
101
-3.0
100
-3.0
SRC
-11.0
Pt
Actual
12.59
12.59
E2.59
7.04
7.48
12.16
12.16
12.16
12.16
12.16
12.16
12.16
12.16
12.17
13.03
13.04
13.11
13.15
12.96
13.02
13.02
13.02
12.16
13.02
13.03
13.03
6.85
7.31
7.91
7.31
7.61
12.74
13.32
14.38
21.41
22.35
24.79
26.22
37.03
51.37
51.38
51.38
51.38
54.84
Pn
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
Flow Density
Actual
13.0
13.4
5.0
The maximum velocity is 20.82 and it occurs in the pipe between nodes M1 and M2
0.05
0.05
Page 4
Date 03/28/16
Area Press
Req.
256 7.039
256 7.0
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Final Calculations - Hazen -Williams
NP Mechanical
ESTATES
Page 5
Date 03/28/16
Hyd.
Qa Dia.
Fitting
Pipe
Pt
Pt
Ref.
"C"
or
Ftng's
Pe
Pv ******* Notes "'""
Point
Qt Pf/Ft
Eqv. Ln.
Total
Pf
Pn
H 1
0.0
1.101
N
7.0
1.000
12.592
to
150.0
0.0
7.000
-0.433
D1
0.0
0.0
0.0
8.000
0.0
Vel = 0
0.0
0.0
12.159
K Factor = 0
H2
0.0
1.101
N
7.0
1.000
12.593
to
150.0
0.0
7.000
-0.433
D2
0.0
0.0
0.0
8.000
0.0
Vel = 0
0.0
0.0
12.160
K Factor = 0
H3
0.0
1.101
N
7.0
1.000
12.594
to
150.0
0.0
7.000
-0.433
D3
0.0
0.0
0.0
8.000
0.0
Vel = 0
0.0
0.0
12.161
K Factor = 0
H4
13.00
1.101
N
7.0
1.000
7.039
K Factor = 4.90
to
150.0
0.0
7.000
-0.433
D4
13.0
0.0306
0.0
8.000
0.245
Vel = 4.38
0.0
13.00
6.851
K Factor = 4.97
H5
13.40
1.101
N
7.0
1.000
7.482
K Factor = 4.90
to
1 50.0
n n
7 nnn
-n 422
D5
13.4
0.0325
0.0
8.000
0.260
Vel = 4.52
0.0
13.40
7.309
K Factor = 4.96
D1
0.0
1.101
O
5.0
5.250
12.159
to
150.0
0.0
5.000
0.0
1
0.0
0.0
0.0
10.250
0.0
Vel = 0
1
0.23
1.101
3 R
3.0
9.417
12.159
to
150.0
0.0
3.000
0.0
2
0.23
0.0001
0.0
12.417
0.001
Vel = 0.08
2
0.42
1.101
R
1.0
1.583
12.160
to
150.0
0.0
1.000
0.0
3
0.65
0.0
0.0
2.583
0.0
Vel = 0.22
0.0
0.65
12.160
K Factor = 0.19
D2
0.0
1.101
O
5.0
1.250
12.160
to
150.0
0.0
5.000
0.0
3
0.0
0.0
0.0
6.250
0.0
Vel = 0
3
0.65
1.101
R
1.0
10.833
12.160
to
150.0
0.0
1.000
0.0
4
0.65
0.0001
0.0
11.833
0.001
Vel = 0.22
0.0
0.65
12.161
K Factor = 0.19
D3
0.0
1.101
O
5.0
1.250
12.161
to
150.0
0.0
5.000
0.0
4
0.0
0.0
0.0
6.250
0.0
Vel = 0
4
0.65
1.101
N
7.0
2.417
12.161
to
150.0
0.0
7.000
0.0
5
0.65
0.0001
0.0
9.417
0.001
Vel = 0.22
Computer Programs by Hydratec Inc. Route 111
Windham N.H.
USA 03087
Finial Calculations - Hazen -Williams
NP Mechanical
ESTATES
Page 6
Date 03/28/16
Hyd.
Qa Dia.
Fitting
Pipe
Pt
Pt
Ref.
"C"
or
Ftng's
Pe
Pv ***"*** Notes
Point
Qt Pf/Ft
Eqv. Ln.
Total
Pf
Pn
5
0.0 1.101
R 1.0
16.667
12.162
to
150.0
N 7.0
8.000
0.0
6
0.65 0.0001
0.0
24.667
0.003 Vel = 0.22
6
0.0
1.101
N
7.0
2.000
12.165
to
150.0
0.0
7.000
0.866
7
0.65
0.0002
0.0
9.000
0.002 Vel = 0.22
7
0.0
1.101
5R
5.0
40.083
13.033
to
150.0
O
5.0
10.000
0.0
8
0.65
0.0001
0.0
50.083
0.006 Vel = 0.22
8
2.62
1.101
2R
2.0
19.250
13.039
to
150.0
N
7.0
9.000
0.0
9
3.27
0.0024
0.0
28.250
0.067 Vel = 1.10
0.0
3.27 13.106 K Factor = 0.90
8 -2.62 1.101
2R 2.0 12.667 13.039
to 150.0
0.0 2.000 0.0
12 -2.62-0.0016
0.0 14.667 -0.024
0.0
-2.62
13.015
9
to
10
10
to
11
10
to
22
22
to
21
22
to
12
12
to
13
13
to
B
B
to
C
C
to
14
3.27 1.101
150.0
3.27 0.0024
9.46 1.101
150.0
12.73 0.0296
R 1.0
12.667
13.106
O 5.0
6.000
0.0
0.0
18.667
0.044
O 5.0
0.583
13.150
0.0
5.000
0.0
0.0
5.583
0.165
0.0
12.73
_
13.315
-9.46
1.101
R
1.0
4.917
13.150
150.0
O
5.0
6.000
0.0
-9.46
-0.0170
0.0
10.917
-0.186
-3.27
1.101
N
7.0
0.583
12.964
150.0
0.0
7.000
4.764
-12.73
-0.0294
0.0
7.583
-0.223
0.0
-12.73
17.505
3.27
1.101
2R
2.0
14.333
12.964
150.0
O
5.0
7.000
0.0
3.27
0.0024
0.0
21.333
0.051
-2.62
1.101
N
7.0
2.083
13.015
150.0
0.0
7.000
0.0
0.65
0.0001
0.0
9.083
0.001
Vel = 0.88
K Factor = -0.73
Vel = 1.10
Vel = 4.29
K Factor = 3.49
Vel = 3.19
Vel = 4.29
K Factor = -3.04
Vel = 1.10
Vel = 0.22
0.0
1.101
4R
4.0
40.083
13.016
150.0
N
7.0
11.000
0.0
0.65
0.0001
0.0
51.083
0.006 Vel = 0.22
0.0
1.101
N
7.0
2.000
13.022
150.0
0.0
7.000
-0.866
0.65
0.0001
0.0
9.000
0.001 Vel = 0.22
0.0
1.101
R
1.0
4.000
12.157
150.0
O
5.0
6.000
0.866
0.65
0.0002
0.0
10.000
0.002 Vel = 0.22
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
Final Calculations - Hazen -Williams
NP Mechanical
ESTATES
Page 7
Date 03/28/16
Hyd.
Qa Dia.
Fitting
Pipe
Pt
Pt
Ref.
"C"
or
Ftng's
Pe
Pv ''"""' Notes
Point
Qt Pf/Ft
Eqv. Ln.
Total
Pf
Pn
14
to
2
14
15
to
16
16
to
1
D4
to
19
19
to
20
20
to
21
19
D5
to
18
18
to
17
1.0
12.667
13.025
-0.23
1.101
R
150.0
O
5.0
6.000
-0.866
0.42
0.0001
0.0
18.667
0.001
0.0
0.42
12.160
0.23
1.101
R
1.0
13.500
13.025
150.0
N
7.0
8.000
0.0
0.23
0.0
0.0
21.500
0.0
0.0
1.101
R
1.0
12.750
13.025
150.0
N
7.0
8.000
0.0
0.23
0.0
0.0
20.750
0.001
0.0
1.101
R
1.0
4.000
13.026
150.0
0.0
1.000
-0.866
0.23
-0.0002
0.0
5.000
-0.001
0.0
0.23
12.159
13.00
1.101
O
5.0
9.917
6.851
150.0
0.0
5.000
0.0
13.0
0.0307
0.0
14.917
0.458
-0.27
1.101
N
7.0
13.333
7.309
150.0
0.0
7.000
0.0
12.73
0.0295
0.0
20.333
0.599
0.0
1.101
N
7.0
10.000
7.908
150.0
0.0
7.000
9.095
12.73
0.0295
0.0
17.000
0.502
0.0
12.73
17.505
0.27
1.101
R
1.0
2.083
7.309
150.0
0.0
1.000
0.0
0.27
0.0
0.0
3.083
0.0
13.40
1.101
N
7.0
2.000
7.309
150.0
0.0
7.000
0.0
13.67
0.0337
0.0
9.000
0.303
0.0
1.101
R
1.0
13.750
7.612
150.0
2 P
2.0
10.000
4.331
13.67
0.0337
N
7.0
23.750
0.800
17
0.0
1.101
to
150.0
11
13.67
0.0336
11
12.73
1.101
to
150.0
TRA
26.4
0.1138
0.0
26.40
Vel = 0.14
K Factor = 0.12
Vel = 0.08
Vel = 0.08
Vel = 0.08
K Factor = 0.07
Vel = 4.38
Vel = 4.29
Vel = 4.29
K Factor = 3.04
Vel = 0.09
Vel = 4.61
Vel = 4.61
N 7.0
10.000
12.743
0.0
7.000
0.0
0.0
17.000
0.572 Vel = 4.61
N 7.0
2.333
13.315
0.0
7.000
0.0
0.0
9.333
1.062 Vel = 8.90
14.377 K Factor = 6.96
TRA
26.40
1.101
2R
2.0
9.000
14.377
to
150.0
S
9.563
18.562
3.898
BR
26.4
0.1137
N
7.0
27.562
3.135
Vel = 8.90
BR
5.00
1.101
O
5.0
1.000
21.410
Qa = 5
to
150.0
0.0
5.000
0.0
X
31.4
0.1567
0.0
6.000
0.940
Vel = 10.58
Computer Programs by Hydratec Inc. Route 111
Windham N.H.
USA 03087
Final Calculations - Hazen -Williams
NP Mechanical
ESTATES
Page 8
Date 03/28/16
Hyd.
Qa
Dia.
Fitting
Pipe
Pt Pt
Ref.
"C"
or
Ftng's
Pe Pv *''*'" Notes """
Point
Qt
Pf/Ft
Eqv.
Ln.
Total
Pf Pn
X
0.0
1.598
E
5.000
22.350
5.828
to
150.0
0.0
5.828
2.166
EL
31.4
0.0255
0.0
10.828
0.276 Vel = 5.02
EL
0.0
1.598
E
5.828
50.000
24.792
to
150.0
0.0
5.828
0.0
M1
31.4
0.0256
0.0
55.828
1.427 Vel = 5.02
M 1
0.0
0.785
to
150.0
M2
31.4
0.8140
M2
0.0
0.995
to
150.0
CM
31.4
0.2567
CM
0.0
7.68
to
150.0
102
31.4
0.0
102
to
101
101
to
100
100
101
to
SRC
102
to
SRC
-25.10 7.68
150.0
6.3 0.0
-3.97 7.68
150.0
2.33 0.0_
0.0 7.68
150.0
2.33 0.0
0.0 1.000
0.0 0.0
0.0 1.000
T 5.841
50.000
0.0
5.841
0.0
55.841
F 11.278
965.000
T 43.857
55.135
0.0
1020.135
F 11.278
1960.000
T 43.857
55.135
0.0
2015.135
F 11.278
880.000
T 43.857
55.135
0.0
935.135
26.219
10.000
0.814
37.033
0.0
14.333
51.366
0.0
0.012
51.378
0.0
0.002
51.380
0.0
0.0
T 43.857 445.000 51.380
0.0 43.857 3.465
0.0 488.857 0.0
3.98
7.68
T 43.857
485.000
150.0
0.0
43.857
3.98
0.0
0.0
528.857
0.0
3.98
_
25.10
7.68
T 43.857
130.000
150.0
0.0
43.857
25.1
0.0
0.0
173.857
0.0
25.10
Fixed Loss = 10
Vel =
20.82
Vel =
12.96
Vel =
0.22
Vel =
0.04
Vel = 0.02
Vel = 0.02
54.845 K Factor = 0.31
51.380
3.465
0.0 Vel = 0.03
54.845 K Factor = 0.54
51.378
3.465
0.002
54.845
Vel = 0.17
K Factor = 3.39
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
I
Riverside County Fire Department
Riverside Office:
2300 Market Street, Ste. 150
Riverside, CA 92501
Phone: (951) 955-4777 - Fax: (951) 955-4886
PLAN REVIEW FORM
® New ❑ Re -Submittal # ❑ As-builts
Fire Protection Planning
Palm Desert Office:
77-933 Las Montanas Rd., Ste 201
Palm Desert CA 92211
Phone: (760) 863-8886 - Fax: (760) 863-7072
Permit No.
Project Information (Please Print) 6,1.1 U�-90
Pro'e t N TR 36537-1 PGA Estates KAOdP I
1 c ame. I h d d
Address: LOT 74/ 80-444 Champions Way/ Plan 3
City & Zip: La Quinta
Contact Information
CONTACT PERSON: Rachel Horns
Mailing Address: 9225 Stellar Court, Suite A
City & zip Corona 92883
Phone No.: 951-667-4220 x349
Office Use Only
Riverside Coumty Fire
offieCd ,..-r, _ marshal
\W11kc 9121 0i6.
�y
(InsC
ave rea an understand that Fire Dept. fees are
Deposit Based Fees and there may be additional
money due prior to or after project final.
Sign:
Print: Rachel Hornsby
Billing Information
BILL TO:
Mailing Address:
City & Zip
Fax: 951-667-4216 Phone No.:
Email: RACHEL.HORNSBY@RICESERVICESINC.COM Email:
❑ Same as Contact Info
Fax:
The person listed on "Billing Information" will receive ALL billing, correspondence and refunds for any work billed to
this permit. Any changes in billing information must be made in writing to our office.
Plan Review Type Check a ro riate items a
❑ Commercial ❑ Industrial 17 Residential ❑ Special Event ❑ Other
❑ Building ❑ Building Tenant Improvement ( New / Existing ) ❑ High Fire Area
8 Sprinkler System ❑ TI Sprinkler System ❑ Sprinkler Monitoring ❑ Fire Alarm System
❑ Hood & Duct Suppression System ❑ Other Suppression System ❑ Spray Booth ❑ Cell Site
❑ High Pile/Racks ❑ Other: ❑ Underground Water
Story a Tank Submittals: ❑ Dispensers Only ❑ Above Ground ❑ Underground
Fee Paid: i,U ILA- 00
Date Paid:
Check#
Received By
Receipt#(OCR)
f T OL.
Form I — Revised 7/25/2012
Reviewed by: [� Z
PC Review Date: /S
0 Approved ❑ Denied
Plans Stamped: ItYes ONO
Letter Attached: ®Yes ONO
Job Card Included: Oyes []No
❑DBF
Called for Pick -Up
R
Date: /I� By: !
Picked- p -, _-
Date: ��� C By: bae ryl/(� // w
Shipped By / Method
❑DBF
614 X 4 = a. (A 5 I0. Do Visit us at www.rvcfire.ora
Cervantes, Thomas@CALFIRE
Subject: 2. LAQ-I6-RS-033 - PGA WEST/ ESTATES - RES OH ROUGH
Location: 80444 CHAMPIONS WAY, LOT 74, LA QUINTA
Start: Wed 8/10/2016 10:00 AM
End: Wed 8/10/2016 11:00 AM
Recurrence: (none)
Organizer: Cervantes, Thomas@CALFIRE
Rep. Name: Frankie
Phone#:
HYDRANT SYSTEM
Co. Name:
Cell#: 951-376-7634
PASS FAIL
NP Mechanical
CrossSt:
FIRF AI ARM
PARR G
Thrust block pre -pour
Rough -wire inspection
Underground rou h
Function test
Underground hydro
Duct detectors/velocity
Flush
24 hr. battery test
Final
Sprinkler monitoring
SPRINKLER U.G.
Final
Thrust block pre -pour
SPECIAL SUPPRESSION
Underground rough
Door fan test
Underground hydro
Abort test
Flush
Mechanical shutdown
Final
Detector test
FIRE SPRINKLER
Deluge/pre-action
Weld inspection
Final
X
I Overhead rough piping
�C,'
UST/AST TANK
Overhead hydro
Installation
UG flush / OK to connect
Removal
Main drain/inspect. Test
Emergency shut off
High pile storage
Primary piping
In-racksprinklers
Secondary piping
Hose racks
Dispensers & shear valves
Final
Final
KITCHEN HOOD EXTINGUISHING
MISC. INSPECTION
Detections stem
I Spray booths
Function Test
Hood/duct extin uishin
Gas/Electrical shut-off
High pile rack storage
Nozzle model/placement
H.P. vents/access/corridors
Fire alarm connection
Tract access/hydrant verification
Final
Other:
SPRAY BOOTHS
KNOX SYSTEM
Installation
Building Knox box
Air flow test
Gate access Knox box/padlock
Mechanical interlock
BUILDING INSPECTIONS
Extinguishing system
T/I final
Fire alarm connection
Shell final
Final
Final for occupancy
Start Time:
Finish Time:
Start Time:
I Finish Time:
1
Gillespie, James@CALFIRE
Subject: 2. LAQ-I6-RS-033 - PGA WEST/ ESTATES - RES SPK FINAL
Location: 80444 CHAMPIONS WAY, LOT 74, LA QUINTA
Start: Mon 11/21/2016 10:00 AM
End: Mon 11/21/2016 11:00 AM
Recurrence: (none)
Organizer: Gillespie, James@CALFIRE
Rep. Name:
Phone#:
Frankie
Co. Name:
Cell#: 951-376-7634
NP Mechanical
k.ross0t:
HYDRANT SYSTEM
PASS
FAIL
FIRE ALARM
PASS
FAIL
Thrust block pre -pour
Rough -wire inspection
Underground rough
Function test
Underground hydro
Duct detectors/velocity
Flush
24 hr. battery test
Final
Sprinkler monitoring
SPRINKLER U.G.
I
Final
Thrust block pre -pour
SPECIAL SUPPRESSION
Underground rough
Door fan test
Underground hydro
Abort test
Flush
Mechanical shutdown
Final
Detector test
FIRE SPRINKLER
I Deluge/pre-action
Weld inspection
Final
Overhead rough piping
UST/AST TANK
Overhead hydro
Installation
UG flush / OK to connect
Removal
Main drain/inspect. Test
Emergency shut off
High pile storage
Primary piping
In-racksprinklers
I Secondary piping
Hose racks
Dispensers & shear valves
X
I Final (
Final
KITCHEN HOOD EXTINGUISHING
MISC. INSPECTION
Detections stem
Spray booths
Function Test
Hood/duct extinguishing
Gas/Electrical shut-off
High pile rack storage
Nozzle model/placement
H.P. vents/access/corridors
Fire alarm connection
Tract access/hvdrant verification
Final
Other:
SPRAY BOOTHS
KNOX SYSTEM
Installation
Building Knox box
Air flow test
Gate access Knox box/padlock
Mechanical interlock
BUILDING INSPECTIONS
Extinguishing system
T/I final
Fire alarm connection
Shell final
Final
Final for occupanc
Start Time:
Finish Time:
Start Time:
Finish Time:
1
Riverside County Fire Department Fire Protection Planning Section
L3
Riverside Office: 2300 Market St, Ste. 150, Riverside, CA 92501 Ph (951) 9554777 Fax (951) 955-4886
Murrieta Office: 39493 Las Alamos Rd., Ste A, Murrieta, CA 92563 Ph (951) 6D0-6160 Fax (951) 600-6164
Palm Desert Office: 77-933 Las Montanas Rd., * 201 Palm Desert, CA 922114131 Ph. (760) 863-8886 (760) 863-7072
Fire Department Clearance/Release
Date: 11 /21 /2016
To: LA QUINTA B&S
Fax-
Tract/Parcel Map #: PGA WEST ESTATES/PLAN 3
Permit/Lot #: LAQ-16-RS-033/LOT 74
,lob Site Address: 80444 CHAMPIONS WAY
LA QUINTA, CA
APPROVED RESIDENTIAL FIRE SPRINKLER SYSTEM
Release For Building Permit(s)
Shell Final Only (No Tenant)
Final For Occupancy
Building Plan Check Fees Paid
Building Plan Check Fees Not Paid
Other Fees
Fees Not Required
If you should have any questions, please contact the appropriate Riverside County Fire Protection
Planning office for further assistance.
uthnrtxin Signature For Release
J. GILLESPIE
Print Name
Form C — Revised 7/28/2014
PROUDLY SERVING THE
UNINCORPORATED AREAS
OF RIVERSIDE COUNTY
AND THE CITIES OF:
BANNING
BEAUMONT
CALI M ESA
CANYON LAKE
COACHELLA
DESERT HOT SPRINGS
EASTVALE
INDIAN WELLS
INDIO
JURUPA VALLEY
LAKE ELSINORE
LA QUINTA
MENIFEE
MORENO VALLEY
NORCO
PALM DESERT
PERRIS
RANCHO MIRAGE
RUBIDOUx CSD
SAN JACINTO
TEMECULA
WILDOMAR
BOARD OF
SUPERVISORS:
KEVIN JEFFRIES
DISTRICT 1
JOHN TAVAGLIONE
DISTRICT 2
CHARLES WASHINGTON
DISTRICT 3
JOHN BENOIT
DISTRICT 4
MARION ASHLEY
DISTRICT 5
CAL FIRE - RIVERSInE UNIT
t_ lERSIDE COUNTY FIRE . _PARTMENT
OFFICE OF THE FIRE MARSHAL
77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 92211-4131 • Phone (760) 863-8886
• Fax (760) 863-7072
www.rvcfire.org
7/18/2016
NP Mechanical
9225 Stellar Court #A
Corona, CA 92883
Re: Residential Fire Sprinkler Plan Review — PGA Estates Lot #74
LAQ-I6-RS-033 / 80-444 Champions Way, La Quinta, CA
The sprinkler plans you submitted for the above referenced project have been reviewed by
Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with
the following conditions.
Permanently marked identification signs shall be attached to all control valves.
The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff:
(a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal
operating pressure
(b) Final inspection
The Fire Department approved plans and conditions letter must be at the job site or NO inspection
will be performed.
Applicant/installer shall be responsible to contact the Fire Department to schedule inspections.
Requests for inspections are to be made at least 72 hours in advance and may be arranged by
calling (760)863-8886.
SUBJECT TO FIELD INSPECTION - Nothing in our review shall be construed as encompassing
structural integrity. Review of this plan does not authorize or approve any omission or deviation
from all applicable regulations. Final approval is subject to field inspection.
All questions regarding the meaning of these conditions should be referred to the Office of the Fire
Marshal staff at (760)863-8886.
Kohl Hetrick - Fire Safety Specialist