Loading...
LAQ-17-RS-047 Monterra Plan 3ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT WOODBRIDGE PACIFIC GROUP LLC 27271 LAS RAMBLAS SUITE #100 MISSION VIEJO CA 92691 (949)348-8162 rrichards@woodbridge pacific.com CONTRACTOR WOODBRIDGE PACIFIC GROUP LLC 27271 LAS RAMBLAS SUITE #100 MISSION VIEJO CA 92691 (949)348-8162 rrichards@woodbridge pacific.com OWNER LA QUINTA HOUSING 1, LLC 27285 LAS RAMBLAS, SUITE 230 MISSION VIEJO CA 92691 (949)348-8162 rrichards@woodbridge pacific.com CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES REFUND MIRTA LERMA 11/1/2017 11/1/2017 REFUND ON BUIDLING PERMIT LICENSE CONDITIONS Description: MONTERRA / TM 32742 / PLAN 3 / LOT 9 Type: BUILDING RESIDENTIAL Subtype: DWELLING - SINGLE FAMILY DETACHED Status: FINALED Applied: 7/25/2017 SKH Parcel No: 767860009 Site Address: 81805 FOUR SEASONS LA QUINTA,CA 92253 Approved: 8/8/2017 MFA Subdivision: TR 32742 Block: Lot: 9 Issued: 8/8/2017 MFA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 3/27/2018 crw Valuation: $220,058.90 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 3,370 SF DWELLING - PLAN 3 LOT 9 [VB/RES-3/CLASS-A/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS, BBQ OR WATER FEATURE. PER 2016 CALIFORNIA BUILDING CODES Fire Permit #LAQ-17-RS-0186. FINANCIAL INFORMATION Printed: Wednesday, February 28, 2024 4:33:22 PM 1 of 7 Permit Details City of La Quinta PERMIT NUMBER BRES2017-0186 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY ART IN PUBLIC PLACES - RESIDENTIAL 270-0000-43201 0 $50.14 $50.14 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH Total Paid for ART IN PUBLIC PLACES - AIPP: $50.14 $50.14 BSAS SB1473 FEE 101-0000-20306 0 $9.00 $9.00 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $9.00 $9.00 DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $942.00 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 $129.00 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $433.00 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH DIF - LIBRARIES 253-0000-43200 0 $344.00 $344.00 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 $40.00 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $2,048.00 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 $116.00 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 $2,842.00 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 $6,894.00 TEMP POWER SERVICE 101-0000-42403 0 $25.33 $25.33 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH Total Paid for ELECTRICAL: $25.33 $25.33 RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $51.68 $51.68 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH Printed: Wednesday, February 28, 2024 4:33:22 PM 2 of 7 Permit Details City of La Quinta PERMIT NUMBER BRES2017-0186 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $152.00 $152.00 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH Total Paid for ELECTRICAL - NEW CONSTRUCTION: $203.68 $203.68 RESIDENTIAL PRECISE GRADING - TRACT HOME 101-0000-42408 0 $139.84 $139.84 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH Total Paid for GRADING: $139.84 $139.84 CONDENSER/COMPRES SOR 101-0000-42402 0 $76.00 $76.00 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH EXHAUST HOOD 101-0000-42402 0 $12.67 $12.67 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH FURNACE 101-0000-42402 0 $76.00 $76.00 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH VENT FAN 101-0000-42402 0 $88.69 $88.69 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH Total Paid for MECHANICAL: $253.36 $253.36 MULTI STRUCTURE PLAN CHECK - EACH 101-0000-42600 0 $50.67 $50.67 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH Total Paid for MULTI STRUCTURE PLAN CHECK - EACH: $50.67 $50.67 MULTI SPECIES RESIDENTIAL 0-8 UNITS - 2017 UPDATE 101-0000-20310 0 $1,245.00 $1,245.00 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH MULTI-SPECIES RESIDENTIAL >14 UNITS - 2017 UPDATE 101-0000-20310 0 $17.00 $17.00 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH Total Paid for MULTI-SPECIES RESIDENTIAL: $1,262.00 $1,262.00 NEW CONSTRUCTION PERMIT 101-0000-42400 0 $621.91 $621.91 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH Total Paid for NEW CONSTRUCTION PERMIT: $621.91 $621.91 Printed: Wednesday, February 28, 2024 4:33:22 PM 3 of 7 Permit Details City of La Quinta PERMIT NUMBER BRES2017-0186 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY BACKFLOW DEVICE 101-0000-42401 0 $12.67 $12.67 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH BUILDING SEWER 101-0000-42401 0 $25.33 $25.33 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH FIXTURE/TRAP 101-0000-42401 0 $266.07 $266.07 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $38.00 $38.00 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH WATER HEATER/VENT 101-0000-42401 0 $12.67 $12.67 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.67 $12.67 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH Total Paid for PLUMBING FEES: $367.41 $367.41 Refund on Building Permit License 101-0000-20310 0 ($17.00)($17.00)10/29/17 R29057 116618 CHECK WOODBRIDGE PACIFIC GROUP LLC MLE Total Paid for Refund on Building Permit License: ($17.00)($17.00) SMI - RESIDENTIAL 101-0000-20308 0 $28.61 $28.61 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH Total Paid for STRONG MOTION INSTRUMENTATION SMI: $28.61 $28.61 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 SINGLE FAMILY DETACHED 224-0000-20320 0 $1,837.44 $1,837.44 7/31/17 R26872 12333 & 12334 CHECK LA QUINTA HOUSING 1, LLC SKH Total Paid for TUMF - RESIDENTIAL: $1,837.44 $1,837.44 TOTALS:$11,731.39 $11,731.39 Printed: Wednesday, February 28, 2024 4:33:22 PM 4 of 7 Permit Details City of La Quinta PERMIT NUMBER BRES2017-0186 UNDERGROUND PLBG DCL 8/21/2017 8/21/2017 APPROVED SEWER CONNECTION DCL 8/21/2017 8/21/2017 APPROVED FOOTINGS JFU 9/11/2017 9/11/2017 APPROVED SLAB JFU 9/11/2017 9/11/2017 APPROVED ROOF NAIL JFU 10/24/2017 10/24/2017 APPROVED W/EXCEPTIO N TOWER TOP PLATES REQUIRE A TOP PLATE SPLICE FIX AT EAST AND WEST WALLS AND THE SHEAR TRANSFER FRAMING CLIPS HAVE NOT YET BEEN INSTALLED AT THIS AREA. THESE ITEMS MUST BE VIEWED AT THE OK TO WRAP INSPECTION. OKAY TO WRAP JFU 11/9/2017 11/9/2017 DISAPPROVE D -CORRECTIONS NOT RESOLVED. -UPON REVIEW, A CORRECTION WAS ACCIDENTALLY LEFT OUT OF PREVIOUS OK TO WRAP INSPECTION CORRECTIONS. TRUSS FIXES ARE REQUIRED AT FRONT ENTRY TOWER WHERE TRUSSES WERE MODIFIED AND NAIL PLATES WERE CUT TO ACCOMMODATE CORBELS. A FINAL WARNING WAS GIVEN TO SUPERINTENDENT TO NOT SCHEDULE INSPECTIONS IF THE WORK IS NOT READY OR A REINSPECTION FEE WILL BE ASSESSED. OKAY TO WRAP JFU 11/14/2017 11/14/2017 APPROVED FRAMING JFU 11/21/2017 11/21/2017 APPROVED ROUGH ELEC JFU 11/21/2017 11/21/2017 APPROVED ROUGH MECH JFU 11/21/2017 11/21/2017 APPROVED ROUGH PLBG JFU 11/21/2017 11/21/2017 APPROVED LATH JFU 11/27/2017 11/27/2017 APPROVED INSULATION JFU 11/29/2017 11/29/2017 PARTIALLY APPROVED ROOF INSULATION ROOF DECK AT LIVING SPACE ONLY (DOES NOT INCLUDE GARAGE). ROOF DECK AT LIVING SPACE ONLY (DOES NOT INCLUDE GARAGE). Printed: Wednesday, February 28, 2024 4:33:22 PM 5 of 7 Permit Details City of La Quinta PERMIT NUMBER BRES2017-0186 INSULATION DCL 12/1/2017 12/1/2017 APPROVED - GARAGE ROOF DECK AND DWELLING. DRYWALL NAIL DCL 12/7/2017 12/7/2017 APPROVED GAS LINE/TEST JFU 1/2/2018 1/2/2018 NOT READY GAS LINE/TEST DCL 1/4/2018 1/4/2018 APPROVED TEMP USE OF PERM PWR DCL 1/30/2018 1/30/2018 APPROVED FINAL FOR OCCUPANCY RGR 2/20/2018 2/20/2018 APPROVED GC- PUBLIC WORKS FINAL GCU 3/14/2018 3/14/2018 APPROVED The general superintendent Joe is on the job site at this time overseeing the subcontractors that are on the job site at this time.The jobsite is clean and in compliance for a final inspection at this time. The drainage system is in stalled, the irrigation systems is installed and the landscaping is completed.The new Home located at 81-805 Four Seasons is in compliance with the rules and regulations set by the City of La Quinta Public Works Department at this time.The weather is 60 degrees with cloudy skies.The wind speed is approximately 5 to 25 mph at this time. FINAL**JFU 3/22/2018 3/22/2018 DISAPPROVE D -ALL OUTDOOR LIGHTING MUST BE CONTROLLED BY AN ON/OFF SWITCH -OUTDOOR LIGHTING CONTROLS NOT PER PLAN--SENT EMAIL TO SUPERINTENDENT TO EXPLAIN HIS OPTIONS FOR CODE COMPLIANT OUTDOOR LIGHTING CONTROL OPTIONS FINAL**JFU 3/27/2018 3/27/2018 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES PARENT PROJECTS Printed: Wednesday, February 28, 2024 4:33:22 PM 6 of 7 Permit Details City of La Quinta PERMIT NUMBER BRES2017-0186 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 3/22/2018 JAKE FUSON BRES2017-0186 - FINAL HERS VERIFICATION DOCUMENTATION BRES2017-0186 - FINAL HERS VERIFICATION DOCUMENTATION.pdf 1 DOC 4/4/2018 JAKE FUSON CERTIFICATE OF OCCUPANCY BRES2017-0186 - CERTIFICATE OF OCCUPANCY.pdf 1 DOC 8/14/2017 LISA NOTTINGHAM Res Spk - Monterra.docx Res Spk - Monterra.docx 0 DOC 11/1/2017 MIRTA LERMA BRES 2017-0183 REFUND Woodbridge Pacific Grap LLC 07.31.17 BRES 2017-0183 REFUND Woodbridge Pacific Grap LLC 07.31.17.pdf 0 IMAGE 3/14/2018 GREG CURDES The physical address .JPG The physical address .JPG 0 IMAGE 3/14/2018 GREG CURDES The job card .JPG The job card .JPG 0 IMAGE 3/14/2018 GREG CURDES The backyard .JPG The backyard .JPG 0 IMAGE 3/14/2018 GREG CURDES The front yard .JPG The front yard .JPG 0 IMAGE 3/14/2018 GREG CURDES The east side yard .JPG The east side yard .JPG 0 BOND INFORMATION FIRE FIRE BUCKET 8/14/2017 8/24/2017 8/14/2017 READY FOR APPROVAL Printed: Wednesday, February 28, 2024 4:33:22 PM 7 of 7 Permit Details City of La Quinta PERMIT NUMBER BRES2017-0186 ' i r Residential Connection Charge Estimate customer Name: i_.'i (jujnto !'ot:jinu 1 i LC Phone No. Parcel No. 767-i361-00° Geo. Address: �5180_ PO tl `er5JosF: Ie, LLB LID:` 67S772 Lot No. ry Size of Lot: 9,14� Sq, ft. Type of Service: R-1: 1 { Duplex: J Triplex: 1....I Block No. W Tract No. -i Apt$: (- SWSC: S Acres: ll SWSC:SU.(l0 /acre WSBFC: Scc: S 4,u51.00 Treatment: $2,436/edu Collection: $2,415/edu Meter: i '100.00 Meter Size: 1 Inch Meter surcharge: i ?,A79 00 Service Sae: i inch Service: r Meter & Service: S - Notes: Rackflow: S Other: TR 32742 Monterra. Special Agreement, credit on WSBFC, Sewer Lateral: SWSC pd on 10/5/15 PZ 1S-6602 (copy attached). Per CVWD 5 approved dwg 40762 a 1" service exists and dwg 40756 a Total: 7,720.00 literal. PZ 17-81Z3 Feehnittan:Satz Lopez IFe-is Appraveci by-. Date: 1� Information Supplied By Customer CVWD System Data Domestic Water Demand` Service Connection•' Max. Flow= 3 2 9PM Max now(= 2 9Pm Min. Pressure= 1 ( psi Iniet Pressure psi F".-Surinklerpt:)t nd Oullct Pressure=_ 6L. •.r: psi Max. Flow= 1 gpin Min. Pressure= ; S c Pbl Meter Size = 1 inch System Tyne: "� Service Size= inch Multi Stand Alone t Prior to Pressure Reprtfatinrt Vplve LENGTH(L)= 1G ••.F4i CaicuJaLlon Purpai6- Seryict. Connection IniclUd�s: ` CVWD USES WORST CASE CONDITION S-4ce Connection rip-L'. WIN Stop, Meter, ChecFValee 8 Shul Off Valve (:3I;ul„0r77USE 1 ,,:ETF< A--:Vli,ii Lzko CaWk, Y<- 85.93 > Go psi 1-IS ` ,..ii'a. li(-rnrler= 6.56 HISS -sr e7% _ � f Fit•vaivc,% .= 13.02 P.D. 66.35 > 57 psi PROP RL V.= 3% max -flow 32.00 GPM 's iv rr: G`I: to rrcvide, scrvltt 'i 6,'i: Uc: ni•ea: t"_zter Gent and Apnovedby: Date: The meter slrine is for plan check purpmesanly. The ultimate fespon:ihiiity resides with the Enginl er nf•Aecnrd for the project. PROUDLY SERVING THE UNINCORPORATED AREAS OF RIVERSIDE COUNTY AND THE CITIES OF: BANNING BEAUMONT CALI M ESA CANYON LAKE COACHELLA DESERT HOT SPRINGS EASTVALE INDIAN WELLS INDIO LAKE ELSINORE LA QUINTA MENIFEE MORENO VALLEY PALM DESERT PERRIS RANCHO MIRAGE RUBIDOUx CSD SAN JACINTO TEMECULA WILDOMAR BOARD OF SUPERVISORS: BOB BUSTER DISTRICT I JOHN TAVAGLIONE DISTRICT 2 JEFF STONE DISTRICT 3 JOHN BENOIT DISTRICT 4 MARION ASHLEY DISTRICT 5 RIV>~RSIDE COUfvTY Fnm= DEPARTMENT IN COOPERATION ' H THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION 77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 92211-4131 . Phone (760) 863-8886 • Fax (760) 863-7072 www.rvefire.org August 14, 2017 Fire Sprinkler Systems, Inc. 705 E. Harrison Street, Ste 200 Corona, CA 92879 Re: Residential Fire Sprinkler Plan Review LAQ-17-RS-047 (City# BRES2017-0186) Monterra — Plan 3 — Lot 9 81805 Four Seasons Place, La Quinta Ref: LAQ-15-RS-145 Plan 3 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department Planning & Engineering personnel and are approved with the following conditions: Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by the Fire Department Planning Division staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. (b) Final inspection. The Fire Department job card, approved plans and conditions letter must be at the job site or NO inspection will be performed. Applicant/installer shall be responsible to contact the Fire Department to schedule inspection(s) a minimum of 72 hours prior to the requested inspection date. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. Applicant/installer shall be responsible to contact the Fire Department to schedule inspection. Sincerely, Lisa Nottingham Fire Safety Specialist Cervantes, Thomas@CALFIRE Subject: 1. LAQ-17-RS-047 - MONTERRA/ LOT 9 - RES OH ROUGH/ HYDRO Location: 81805 FOUR SEASONS PLACE, LOT 9, LA QUINTA Start: Tue 11/21/2017 10:00 AM End: Tue 11/21/2017 10:30 AM Recurrence: (none) Organizer: Cervantes, Thomas@CALFIRE Rep. Name. Carlos Phone#: 800-915-3473 Co. Name: Cel I#: 951-847-2908 Fire Sprinkler Systems, Inc. CrossSt: HYDRANT SYSTEM PASS FAIL FIRE ALARM PASS FAIL Thrust block pre -pour Rough -wire inspection Underground rough Function test Underground hydro Duct detectors/velocity Flush 24 hr. battery test Final Sprinkler monitoring SPRINKLER U.G. Final Thrust block pre -pour SPECIAL SUPPRESSION Underground rough I Door fan test Underground hydro Abort test Flush Mechanical shutdown Final Detector test FIRE SPRINKLER Deluge/pre-action Weld inspection Final X Overhead rough piping UST/AST TANK X Overhead hydro Installation UG flush / OK to connect Removal Main drain/Inspect. Test Emergency shut off High pile storage Primary piping In-racksprinklers Secondary piping Hose racks Dispensers & shear valves Final I Final KITCHEN HOOD EXTINGUISHING MISC. INSPECTION Detections stem SRray booths Function Test Hood/duct extinguishing Gas/Electrical shut-off High pile rack storage Nozzle model/placement H.P. vents/access/corridors Fire alarm connection I Tract access/hydrant verification Final Other: SPRAY BOOTHS KNOX SYSTEM Installation Building Knox box Air flow test Gate access Knox box/padlock Mechanical interlock BUILDING INSPECTIONS Extinguishing system T/I final Fire alarm connection Shell final Final Final for occupancy Start Time: Finish Time: Start Time: Finish Time: 1 1 Riverside County Fire Department Riverside Office: 2300 Market Street, Ste. 150 Riverside, CA 92501 0_ _ Phone: (951) 955-4777 - Fax: (951) 955-4886 PLAN REVIEW FORM B New ❑ Re -Submittal # ❑ As-builts FD Permit # L-Aa m- P-S_ Qla-7 County/City Permit# BUSUI-1 — 01S 6 PROJECT INFORMATION Office of the Fire Marshal Palm Desert Office: 77-933 Las Montanas Rd., Ste 201 Palm Desert CA 92211 Phone: (760. 863-8886 Fax: 760 863-7072 Rivers06M7AFiV Fire Office of the Fire Marshal AUG t 12Q17 Project Name: MONTERRA / TRACT# 32742 / PLAN TYPE 3 Address: LOT 9 81-805 FOUR SEASONS PLACE L`` i --il ' `''`"� r''; ` `'nd 'hor'� n1ak, 1:!' LS C1 GIijj_i?C r:,c3,:r;; r! _ Sign: •]Si. ': nl City 8� Zip: LA QUINTA, CA Print: JA 1 BISHIP L APPLICANT INFORMATION Company Name: FIRE SPRINKLER SYSTEMS, INC Applicant Name: JAMIE BISHIP Address: 705 E. HARRISON STREET #200 Phone: 951-272-2522 City/ zip: CORONA, CA 92879 Email: jamieb@fireinc.net BILLING INFORMATION: B Same as applicant Company Name: FIRE SPRINKLER SYSTEMS, INC Applicant Name: JAMIE BISHIP Address:205 E. HARRISON STREET #200 Phone: 951-272-2522 city/ Zip: CORONA, CA 92879 p� Email:. jamieb@fireinc.net - _ Id' for c;-v V,rk billed to this r)e;nlil.;'.iy c!tm—j C1t;•_ irjlrrr:di'�n rill=si bz n-ku iC i1i V!riliii0 40 Our c."fice_ Plan Review Type (Check appropriate items) ❑Commercial ®Residential ❑Other Construction: IRBuilding ❑Tenant Improvement (New/Existing) ❑Cell Site ❑High Pile/Racks ❑HFA Systems: BSprinkler DTI Sprinkler ❑Sprinkler Monitoring ❑Fire Alarm ❑Hood & Duct Suppression ❑Other Suppression ❑Spray Booth ❑UG Water Other: SEE MASTER PERMIT # LAQ-I5-RS-145 Storage Tanks: ❑Dispensers Only ❑Above Ground # ❑Underground # Fee Paid: LI17G `' 0 fr Called for Pick -Up Reviewed by. ,�, � i" ,1� r Date Paid: 01 ) Date: /� / By: ,V PC Review Date: W 1 9160 A Picked -Up Check#: �� pproved ❑ Denied Date: g%� l►� By: Received By: 1 o t# Shipped By Method Recei OCR Q Letter Attached: ,&es ❑No p ( ) > Job Card Included:,2Yes ❑No BF k _ 6 0 Tr((� DBF DBF For, I — Revised 6/14/2017 r Visit us at www.rvcfii-e.org