Loading...
FSS2022-0206ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT J D MECHANICAL FIRE INC 82579 FLEMING WAY SUITE D INDIO CA 92201 (760)775-6220 KATHY@JDMECHANIC AL.CO CONTRACTOR J D MECHANICAL FIRE INC 82579 FLEMING WAY SUITE D INDIO CA 92201 (760)775-6220 KATHY@JDMECHANIC AL.CO OWNER GALA ASHER 81560 Baffin Ave La Quinta CA 92253 (760)775-6220 CONDITIONS Description: VAN DER WERF / FIRE SPRINKLERS Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: ISSUED Applied: 5/18/2022 ECON Parcel No: 767700015 Site Address: 53405 HUMBOLDT BLVD LA QUINTA,CA 92253 Approved: 6/20/2022 KHET Subdivision: TR 33076-2 Block: Lot: 63 Issued: 7/6/2022 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $10,000.00 Occupancy Type: Construction Type: Expired: 1/8/2023 LIN No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Thursday, April 13, 2023 1:59:40 PM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0206 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING LIN 7/12/2022 7/12/2022 APPROVED Requested as builts for changes made Added 2 heads in garage and moved riser location a few feet; new calcs not required. JD to provide as builts by final. Added 2 heads in garage and moved riser location a few feet; new calcs not required. JD to provide as builts by final. OVERHEAD HYRO LIN 7/12/2022 7/12/2022 APPROVED Requested as builts for changes made Added 2 heads in garage and moved riser location a few feet; new calcs not required. JD to provide as builts by final. REVIEWS PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $333.00 $333.00 7/6/22 WEB12431 638017102 73 CREDIT 1020141 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $250.00 $250.00 7/6/22 WEB12431 638017102 73 CREDIT 1020141 ECON Total Paid for FIRE FEES: $583.00 $583.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 7/6/22 WEB12431 638017102 73 CREDIT 1020141 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 7/6/22 WEB12431 638017102 73 CREDIT 1020141 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$599.00 $599.00 Printed: Thursday, April 13, 2023 1:59:40 PM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0206 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 5/18/2022 Etrakit Contractor 1ST SUBMITTAL HYDRAULIC CALC 1 Document.pdfCalc-1.pdf 1 DOC 5/18/2022 Etrakit Contractor 1ST SUBMITTAL HYDRAULIC CALC 2 Document.pdfCalc-2.pdf 1 DOC 5/18/2022 Etrakit Contractor 1ST SUBMITTAL SPRINKLERS Senju Residential Conceled Pendant.pdf 1 DOC 5/18/2022 Etrakit Contractor 1ST SUBMITTAL PIPING FP-2 Van Der Werf.pdfPiping.pdf 1 DOC 5/18/2022 Etrakit Contractor 1ST SUBMITTAL FP-1 Van Der Werf.pdfSite.pdf 1 DOC 6/14/2022 Etrakit Contractor 1ST SUBMITTAL CVWD Scan_0193.pdf 1 DOC 3/3/2023 Etrakit Contractor Van Der Werf.pdfSite.pdf van der werf.pdf 1 DOC 3/3/2023 Etrakit Contractor Van Der Werf.pdfPiping Plan.pdf van der werf.pdf 1 DOC 3/3/2023 Etrakit Contractor Senju Residential Conceled Pendant.pdf van der werf.pdf 1 DOC 3/3/2023 Etrakit Contractor Document.pdfCalc-3.pdf van der werf.pdf 1 BOND INFORMATION REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE - ETRAKIT (2 WK) KOHL HETRICK 5/18/2022 6/1/2022 6/20/2022 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH – ETRAKIT (1 DAY) PERMIT TECH BUCKET 5/18/2022 5/19/2022 5/19/2022 COMPLETE Printed: Thursday, April 13, 2023 1:59:40 PM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0206 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 3/3/2023 Etrakit Contractor Document.pdfCalc-2.pdf van der werf.pdf 1 DOC 3/3/2023 Etrakit Contractor Document.pdfCalc-1.pdf van der werf.pdf 1 DOC 3/3/2023 Etrakit Contractor 20-11566.pdf van der werf.pdf 1 DOC 6/20/2022 KOHL HETRICK FSS2022-0206 - APPROVED PLANS AND CALCS.pdf FSS2022-0206 - APPROVED PLANS AND CALCS.pdf 1 DOC 6/20/2022 KOHL HETRICK FSS2022-0206 - COA AND JOB CARD.pdf FSS2022-0206 - COA AND JOB CARD.pdf 1 DOC 3/6/2023 KOHL HETRICK FSS2022-0206 - APPROVED - AS- BUILTS.pdf FSS2022-0206 - APPROVED - AS- BUILTS.pdf 1 DOC 7/12/2022 LUCERO INIGUEZ FSS2022-0206 VAN DER WERF 53405 HUMBOLDT BLVD LQ - CORRECTIONS 071222.pdf FSS2022-0206 VAN DER WERF 53405 HUMBOLDT BLVD LQ - CORRECTIONS 071222.pdf 0 DOC 7/12/2022 LUCERO INIGUEZ FSS2022-0206 VAN DER WERF 53405 HUMBOLDT BLVD LQ - REDLINED PLANS 071222.pdf FSS2022-0206 VAN DER WERF 53405 HUMBOLDT BLVD LQ - REDLINED PLANS 071222.pdf 0 Printed: Thursday, April 13, 2023 1:59:40 PM 4 of 4 Permit Details City of La Quinta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iverside County Fire DepartmentLa Quinta Office of the Fire MarshalBy:FIRE SAFETY SPECIALIST03/06/2023 11:33:33 AMThe approval of plans and specifications does notpermit the violation, deletion, omission or faultyinstallation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remainaccessible and exposed for inspection purposesuntil approved by the Fire Department.PERMIT # -FSS2022-0206 - AS-BUILTSKohl HetrickReason: I am approving this documentContact Info: 760-409-5109 214 196 INSPECTOR TEST DETAIL 5' 1" Ball Valve Access Panel (By Others) Exterior Wall of Building Inspector Test to Terminate in a Smooth Bore Corrosion Resistant Orfice With a Flow Equivalent to One Sprinkler NOTE: Access Panel Shall have sign Indicating Inspector Test CPVC HANGERS NO SCALE TOLCO FIG. 24 DOUBLE-FASTENER SIDE-MOUNT HANGER (OR EQUAL) SELF-DRILLING HEX HEAD SCREW TOLCO FIG. 23 DOUBLE-FASTENER STRAP TYPE HANGER (OR EQUAL) TOLCO FIG. 28M OFFSET HANGER (OR EQUAL) TOLCO FIG. 22 SINGLE-FASTENER STRAP-TYPE HANGER (OR EQUAL) TOLCO FIG. 28 DOUBLE-FASTENER STAND-OFF HANGER (OR EQUAL) TOLCO FIG. 29 DOUBLE-FASTENER DOUBLE OFFSET HANGER (OR EQUAL) CPVC HANGER SPACING PIPE SIZE 11/4" 1" MAXIMUM SUPPORT SPACING 6'-6" 6'-0" 2" 8'-0" 11/2"7'-0" SPRINKLER PIPEINSULATION BOTTOM CORD OF ROOF TRUSS OR CEILING JOIST PIPE INSULATION DETAIL www.cadmando.co.uk These blocks were brought to you by CADBloc ksFree.com.For all of your 2D & 3D CAD outs ource requirem ents visit us: C A D M A N D O www.cadblocksfree.com COVER WITH HINGED LID FINISHED GRADE DISC-TYPE WATER METER PLUG VALVE(TYP.)UNION(TYP.) Water Supply Information Static Pressure: Residual Pressure: Residual Flow: Additional Hose Flow: 78.35 psi 58.19 psi 41 GPM 0 GPM 1 1/4"6' -6"1 1/4"16' -0"1" 1' -5" 1" 14' -0"1 1/4"16' -0"1 1/4" 1' -11" 1 1/4" 6' -0" 1 1/4" 4' -11"1"2' -8"1"14' -0"1"4' -2"1" 7' -0" 1 1/4" 1' -0" 1 1/4" 6' -0" 1 1/4" 6' -0" 1 1/4" 1' -0" 1" 2' -8"1"14' -0"1 1/4" 4' -10"1"1' -11"1"16' -0"1"8' -4"1" 1' -2" 1" 12' -0"1"2' -2"1"2' -2"1" 10' -1"1"1' -5"1"10' -1"1"1' -8"1"16' -0"1 1/4" 7' -8" 1" 1' -0"1"3' -0"1 1/4" 9' -5" 1 1/4" 2' -11" 1" 6' -6" 1 1/4" 0' -10"1 1/4"9' -0"1 1/4" 5' -0" 1 1/4" 2' -7"1" 7' -9"1 1/4"7' -1"1" 5' -4" 1 1/4" 2' -11" 1 1/4" 7' -11"1 1/4"8' -4"1 1/4"7' -4"1" 7' -1"1 1/4"6' -8"1 1/4"6' -5"1 1/4" 2' -11" 1 1/4" 8' -0"1"2' -6"1 1/4" 6' -0"1"5' -2"1"1' -8"1"8' -6"1" 7' -1" 1" 4' -4"1"1' -10"1" 7' -2" 1" 4' -3" 1 1/4" 5' -0"1"2' -6"1 1/4" 3' -0"1"1' -3"1"6' -6"1"5' -4"1"8' -8"1" 5' -10" 1" 3' -4"1"4' -2"1"14' -0"1 1/4" 2' -5" 1 1/4" 10' -11" 1 1/4" 3' -5" 1 1/4" 8' -7" 1 1/4" 7' -0"1"2' -11"1"10' -6"1 1/4" 8' -8"1"9' -8"1"10' -2"1 1/4" 3' -4"1"13' -5"1 1/4" 2' -5"1"2' -11"1 1/4" 8' -1" 1 1/4" 1' -0" 1 1/4" 14' -0" 1" 2' -0" 1 1/4" 1' -0" 1 1/4" 10' -4" 1 1/4" 12' -0" 1 1/4" 10' -2" 1 1/4" 10' -7"1 1/4"0' -10"1" 7' -9" 1" 10' -6"1"5' -0"1 1/4" 8' -5" 1 1/4" 6' -0"1"1' -4"1"8' -7"1 1/4" 6' -9" 1 1/4" 12' -0"1"2' -8"1 1/4" 6' -1"1"4' -9"1"6' -2"1 1/4" 6' -2" 1 1/4" 12' -0"1"1' -10"1"10' -0"1"1' -10"1"10' -0"1"2' -8"1 1/4"4' -8"1 1/4"7' -2"1 1/4" 1' -7" 1" 2' -8"1 1/4"6' -4" 1 1/4"5' -8" 1 1/4" 7' -7"1 1/4" 2' -3" 1 1/4"9' -5" 1 1/4" 2' -4" 1" 0' -6" 1 1/4" 6' -5"1"0' -7"1 1/4"1' -6"1"12' -4"1 1/4"8' -6" 1 1/4" 2' -0"1"11' -4"1"7' -2"1"3' -5"1" 0' -7"1"5' -1"1"2' -2"1"5' -7"1"8' -0"1"0' -6"1"2' -8"1 1/4"12' -10"1 1/4" 0' -5"1 1/4"14' -0"1 1/4"2' -10"1 1/4"5' -0"1"5' -7"1 1/4" 4' -8"1"5' -7"1"15' -0"1 1/4" 3' -8" 1 1/4" 2' -2"1"10' -1"1 1/4"9' -5"1"3' -3"1"7' -7"1 1/4"12' -5"1"0' -8"1"9' -3"1" 7' -7"1"1' -9"1"2' -4"1"5' -7"1"15' -0"1"6' -8" 1"6' -8" 1"4' -11" 1"10' -3"1"4' -5"1"12' -0"1"4' -5"1 1/4"3' -5"1 1/4"7' -10"1" 2' -8" 1" 2' -9" 1" 13' -3" 1" 0' -9"1"4' -0"1"4' -0"1 1/4"22' -0"1 1/4"17' -4"1" 7' -3"1"1' -2"1"8' -6"1"8' -4"1 1/4" 5' -2" 1 1/4" 0' -4" 1 1/4" 11' -6"1"7' -10"1"6' -2"1 1/4" 6' -3" 1 1/4" 10' -4" 1 1/4" 3' -3"1"7' -9"1 1/4" 11' -0" 1" 13' -10"1"2' -6"1"7' -3"1" 12' -2"1"4' -9"1"7' -8"1"6' -11"1"0' -11"1"8' -9"1"1' -4"1"7' -5"1"1' -7"1"3' -3"1" 1' -9"1"2' -10"1"6' -0"1"6' -0"1" 2' -8" 1" 2' -9"1"4' -0"1" 13' -3" 1" 0' -9"1"4' -0"1"2' -3"1"2' -3"1"9' -8"1"12' -0"1" 2' -0"1"9' -8"1"12' -0"1"12' -10"1"2' -11"1"12' -10"1"2' -11"1"10' -5"1" 6' -0" 1" 1' -5" 1" 14' -0" 1" 1' -5" 1" 14' -0"Up 1 1/4" x 4' -6"Up 1 1/4" x 9' -6"Up 1 1/4" x 3' -0"Up 1" x 3' -0"Up 1" x 3' -0"Up 1" x 3' -0"Up 1" x 3' -0"Dn 1" x 3' -0"Dn 1 1/4" x 2' -0"Dn 1 1/4" x 2' -0"Dn 1" x 3' -0"1-1/4" RISER Calc-2 Calc-1 INSPECTORS TESTNOTIFICATION DEVICE BY OTHERS MEDIA ROOM 11'-0" KITCHEN 16'-0" DINING 16'-0" POOL POWDER ROOM STORAGE DIRTY KITCHEN COVERED LANAI GREAT ROOM 16'-0" DINING 16'-0" OUTDOOR LOUNGE MASTER BEDROOM 16'-0" MASTER LOUNGE 13'-0" HER CLOSET 13'-0" MASTER BATH 13'-0" HIS CLOSET 13'-0" BEDROOM 3 11'-0" BEDROOM 2 11'-0" BEDROOM 1 11'-0" BATH 3 BATH 2 BATH 1 OFFICE 13'-0" LAUNDRY 11'-0" MAIN POWDER 11'-0" BEDROOM 6 10'-0" BEDROOM 5 10'-0" BEDROOM 4 10'-0" BATH 6 BATH 5 BATH 4 GUEST LOUNGE 16'-0" STORAGE 10'-0" CLOSET 10'-0" CLOSET 10'-0" GARAGE 10'-0"CINEMA 16'-0" GAME ROOM 16'-0" Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-2 R-3 2 Gpm/SqFt 512 Max SqFt 31.0485 GPM 34.0099 Psi 5 GPM 0 GPM BOR TOR DOM 1 5 3 6 2 Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-1 R-3 2 Gpm/SqFt 512 Max SqFt 31.3309 GPM 35.6941 Psi 5 GPM 0 GPM 7 11 10 9 8 Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-3 U 2 .05 Gpm/SqFt 512 Max SqFt 31.1399 GPM 28.6002 Psi 5 GPM 0 GPM 15 12 16 14 13 CALC-3 1 1/4" 6' -9"1 1/4" x 17' -0"1 1/4"5' -1"1 1/4" 1' -9" 1 1/4" 1' -2"1 1/4" x 14' -0"1" 2' -5"1"12' -0"1" 5' -0" 1" 5' -0" 1" 5' -0" 1" 5' -0"1 1/4" 12' -6" GOLF CART GARAGE SLOPE Fire Sprinkler Riser Detail TOR BOR DomesticSupply Check Flow Control 1-1/4" CPVC Flow Switch Note Wiring by Others 300psi Gage Sprinkler Box with Wrench & twoSprinkler Heads Each Type 1/2" Drain toOutside1-1/4"1-1/4"1-1/2" UNDERGROUND BY OTHERS Notification DeviceWired by Others not to scale Module Must Connect to the MultiStation Smoke Alarm System andthe Fire Sprinkler Flow Switch( all wiring by others ) jd@jdmechanical.co Scale Project number Date Drawn by Checked by 82579 Fleming Way Suite DIndio Ca. 92201(760) 775-6220C-16 License # 1020141MECHANICALINCAs indicated 3/2/2023 12:57:00 PMFP-2 Piping Plan Project Number Van Der Werf 03-02-23 JA JDVAN DER WERF RESIDENCEMadison Club Lots 63B & 64BLa Quinta, Ca.3/32" = 1'-0"1 Piping PlanSprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 119 Senju 1/2 Light Concealed Temperature - 162 Finish - B Quick Response Model - Mirage SIN - SS8464 K Factor - 4.9 SS8464 4.9 1/2" 162 °F 17 Senju 1/2 Light Pendent Temperature - 205 Finish - C Special Response Model - Micromatic SIN - SS8464 K Factor - 4.9 SS8464 4.9 1/2" 205 °F : 136 Total No. of Sprinklers: 136 JD Mechanical Fire 82579 Fleming Way Suite D Your Street Address 2 Indio, Ca. 92201 760-775-6220 Job Name : Van Der Werf Drawing : Location : Remote Area : Calc-1 Contract : Data File : Van Der Werf Area Calc-1.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical FirePage 1 Van Der WerfDate 10203040E50R60U70S80S90E100R110P12013014015010 20 30 40 50 60 70 80 90FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 78.35 C2 - Residual Pressure: 58.19 C2 - Residual Flow : 41 D1 - Elevation : 5.713 D2 - System Flow : 31.331 D2 - System Pressure : 35.694 Hose ( Demand ) : _______D3 - System Demand : 31.331 Safety Margin : 30.399 D1D2Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical FirePage 2 Van Der WerfDate Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 3 Van Der Werf Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure 4 78.35 58.19 41.0 66.093 31.33 35.694 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 7 10.19 4.9 7.04 13.0 0.05 256 8 12.0 7.05 9 12.0 10.63 10 14.0 14.3 TOR 11.0 24.81 DOM 1.52 29.58 5.0 BOR -3.0 32.15 4 -3.0 35.69 11 10.19 4.9 7.4 13.33 0.05 256 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 4 Van Der Werf Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 7 10.19 4.90 13.00 1 N 7.0 13.950 150 7.040 to O 5.0 12.000 -0.784 8 12 13.0 1.101 25.950 0.0307 0.796 Vel = 4.38 8 12 13.33 1 R 1.0 23.580 150 7.052 to N 7.0 8.000 0.0 9 12 26.33 1.101 31.580 0.1132 3.574 Vel = 8.87 9 12 0.0 1.25 4R 4.0 100.460 150 10.626 to 2N 16.0 26.000 -0.866 10 14 26.33 1.394 O 6.0 126.460 0.0359 4.535 Vel = 5.53 10 14 0.0 1.25 2O 12.0 201.930 150 14.295 to 19R 19.0 55.000 1.299 TOR 11 26.33 1.394 3N 24.0 256.930 0.0359 9.215 Vel = 5.53 TOR 11 0.0 1.25 R 1.0 9.480 150 24.809 to N 8.0 9.000 4.106 DOM 1.52 26.33 1.394 18.480 0.0359 0.663 Vel = 5.53 DOM 1.52 + 5.00 5.00 1.25 N 8.0 4.520 150 29.578 to 8.000 1.958 BOR -3 31.33 1.394 12.520 0.0494 0.619 Vel = 6.59 BOR -3 0.0 1.5 2N 18.0 121.130 150 32.155 to 18.000 0.0 4 -3 31.33 1.598 139.130 0.0254 3.539 Vel = 5.01 0.0 4 31.33 35.694 K Factor = 5.24 11 10.19 4.90 13.33 1 N 7.0 6.560 150 7.400 to 7.000 -0.784 8 12 13.33 1.101 13.560 0.0322 0.436 Vel = 4.49 0.0 8 13.33 7.052 K Factor = 5.02 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire 82579 Fleming Way Suite D Your Street Address 2 Indio, Ca. 92201 760-775-6220 Job Name : Van Der Werf Drawing : Location : Lots 63B & 64B Madison Club Remote Area : Calc-2 Contract : Data File : Van Der Werf Area Calc-2.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical FirePage 1 Van Der WerfDate 10203040E50R60U70S80S90E100R110P12013014015010 20 30 40 50 60 70 80 90FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 78.35 C2 - Residual Pressure: 58.19 C2 - Residual Flow : 41 D1 - Elevation : 8.311 D2 - System Flow : 31.048 D2 - System Pressure : 34.010 Hose ( Demand ) : _______D3 - System Demand : 31.048 Safety Margin : 32.286 D1D2Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical FirePage 2 Van Der WerfDate Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 3 Van Der Werf Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure 4 78.35 58.19 41.0 66.296 31.05 34.01 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 1 16.19 4.9 7.04 13.0 0.05 256 2 14.0 9.51 3 14.0 11.06 TOR 11.0 23.21 DOM 1.52 27.96 5.0 BOR -3.0 30.53 4 -3.0 34.01 5 16.19 4.9 7.09 13.05 0.05 256 6 14.0 9.41 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 4 Van Der Werf Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 1 16.19 4.90 13.00 1 3N 21.0 26.720 150 7.040 to 2R 2.0 23.000 0.948 2 14 13.0 1.101 49.720 0.0307 1.525 Vel = 4.38 2 14 13.05 1.25 2O 12.0 30.060 150 9.513 to 2R 2.0 14.000 0.0 3 14 26.05 1.394 44.060 0.0352 1.549 Vel = 5.48 3 14 0.0 1.25 25R 25.0 241.490 150 11.062 to 3O 18.0 67.000 1.299 TOR 11 26.05 1.394 3N 24.0 308.490 0.0352 10.846 Vel = 5.48 TOR 11 0.0 1.25 R 1.0 9.480 150 23.207 to N 8.0 9.000 4.106 DOM 1.52 26.05 1.394 18.480 0.0352 0.650 Vel = 5.48 DOM 1.52 + 5.00 5.00 1.25 N 8.0 4.520 150 27.963 to 8.000 1.958 BOR -3 31.05 1.394 12.520 0.0486 0.608 Vel = 6.53 BOR -3 0.0 1.5 2N 18.0 121.130 150 30.529 to 18.000 0.0 4 -3 31.05 1.598 139.130 0.0250 3.481 Vel = 4.97 0.0 4 31.05 34.010 K Factor = 5.32 5 16.19 4.90 13.05 1 2N 14.0 24.390 150 7.090 to R 1.0 20.000 0.948 6 14 13.05 1.101 O 5.0 44.390 0.0309 1.371 Vel = 4.40 6 14 0.0 1.25 R 1.0 9.670 150 9.409 to 1.000 0.0 2 14 13.05 1.394 10.670 0.0097 0.104 Vel = 2.74 0.0 2 13.05 9.513 K Factor = 4.23 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire 82579 Fleming Way Suite D Your Street Address 2 Indio, Ca. 92201 760-775-6220 Job Name : Van Der Werf Drawing : Location : Madison Club Lots 63B & 64B Remote Area : Calc-3 Contract : Data File : Van Der Werf Area Calc-3.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical FirePage 1 Van Der WerfDate 10203040E50R60U70S80S90E100R110P12013014015010 20 30 40 50 60 70 80 90FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 78.35 C2 - Residual Pressure: 58.19 C2 - Residual Flow : 41 D1 - Elevation : 5.648 D2 - System Flow : 31.14 D2 - System Pressure : 28.600 Hose ( Demand ) : _______D3 - System Demand : 31.14 Safety Margin : 37.630 D1D2Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical FirePage 2 Van Der WerfDate Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 3 Van Der Werf Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure 4 78.35 58.19 41.0 66.231 31.14 28.6 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 12 10.04 4.9 7.1 13.06 0.05 256 13 11.0 7.12 14 11.0 10.49 15 14.0 13.16 TOR 11.0 17.52 5.0 DOM 1.52 22.53 BOR -3.0 25.1 4 -3.0 28.6 16 10.04 4.9 7.13 13.08 0.05 256 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 4 Van Der Werf Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 12 10.04 4.90 13.06 1 N 7.0 5.960 150 7.100 to R 1.0 8.000 -0.416 13 11 13.06 1.101 13.960 0.0309 0.432 Vel = 4.40 13 11 13.08 1 2O 10.0 19.240 150 7.116 to R 1.0 11.000 0.0 14 11 26.14 1.101 30.240 0.1116 3.376 Vel = 8.81 14 11 0.0 1.25 6N 48.0 58.230 150 10.492 to O 6.0 54.000 -1.299 15 14 26.14 1.394 112.230 0.0354 3.971 Vel = 5.50 15 14 0.0 1.25 2N 16.0 61.410 150 13.164 to O 6.0 25.000 1.299 TOR 11 26.14 1.394 3R 3.0 86.410 0.0354 3.058 Vel = 5.50 TOR 11 + 5.00 5.00 1.25 R 1.0 9.480 150 17.521 to N 8.0 9.000 4.106 DOM 1.52 31.14 1.394 18.480 0.0489 0.904 Vel = 6.55 DOM 1.52 0.0 1.25 N 8.0 4.520 150 22.531 to 8.000 1.958 BOR -3 31.14 1.394 12.520 0.0489 0.612 Vel = 6.55 BOR -3 0.0 1.5 2N 18.0 121.130 150 25.101 to 18.000 0.0 4 -3 31.14 1.598 139.130 0.0251 3.499 Vel = 4.98 0.0 4 31.14 28.600 K Factor = 5.82 16 10.04 4.90 13.08 1 N 7.0 5.960 150 7.129 to 7.000 -0.416 13 11 13.08 1.101 12.960 0.0311 0.403 Vel = 4.41 0.0 13 13.08 7.116 K Factor = 4.90 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. They are decorative and fast responding. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows for easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for residential occupancies and is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar1/2) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents to escape or evacuate in case of a fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. “Lead Free” is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA’s Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. Approvals: Sprinkler Identification Number (SIN): Maximum Working Pressure: Discharge Coefficient (Nominal K-Factor): Temperature Rating: Color Code (Sprinkler) Color Code (Cover Plate) Vertical Adjustment: Cover Plate Finishes: Standard Finishes- Custom Finishes- Please see chart on Page 8 for more detail. Physical Characteristics: In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is reached, internal components of the sprinkler fall apart. This leads to the water flow to be distributed on the affected fire area. (Ref. Figure 2) DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. Locations of sprinklers must follow the obstruction rules of NFPA 13, 13D and 13R for Residential Sprinklers. The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Refer to NFPA 13D, 13R or 13 for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to the exposure of a heat source other than an actual fire. Available Sprinkler Temperature Ratings Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating Maximum Ambient Ceiling Temperature Temperature Rating of the Cover Plate Assembly Ordinary 162°F (72°C) 100°F (38°C) 140°F (60°C) Intermediate 175°F (79°C 150°F (66°C) 140°F (60°C) 1) Intermediate 175°F (79°C) 150°F (66°C) 162°F (72°C) 1) Maximum ambient temperature for the Cover Plate Assembly is 100°F (38°C). Model RC-RES sprinklers should not be installed where they may be subjected to a corrosive environment including the following: Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) – Solder Joint) All residual flux must be removed from the interior and exterior of the copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and/or leakage in the sprinkler system. The minimum required sprinkler flow rates for systems designed to NFPA 13D or 13R are given in TABLE A as a function of temperature rating and the maximum allowable coverage area. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of “design sprinklers” as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in TABLE A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. A minimum discharge of 0.1GPM/sq.ft. [4.07LPM/sq.m] over the “design area” comprised of the four most hydraulically demanding sprinklers for the actual coverage area being protected by the four sprinklers. For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R or 13 as applicable. Ordinary Temperature Rating 162°F (72°C) Intermediate Temperature Rating 175°F (79°C) Maximum Coverage Area(a) Ft. × Ft. (m ×m) Maximum Spacing Ft. (m) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) 12×12 (3.7×3.7) 12 (3.7) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 14×14 (4.3×4.3) 14 (4.3) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 15×15 (4.6×4.6) 15 (4.6) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 16×16 (4.9×4.9) 16 (4.9) 13 (49.2) 7.0 (0.48) 14 (53.0) 8.2 (0.57) 18×18 (5.5×5.5) 18 (5.5) 17 (64.3) 12.0 (0.83) 18 (68.1) 13.5 (0.93) 20×20 (6.1×6.1) 20 (6.1) 21 (79.5) 18.4 (1.27) Smooth Ceilings 3/8 to 7/8 Inches. Beamed Ceilings per NFPA 13D, 13R or 13 Installed in beam 3/8 to 7/8 inches below bottom of beam. Concealed 8 (2.4) (a) For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. TABLE A) The Model RC-RES must be installed in accordance with the following instructions: The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inches (50.8mm) as shown in Figure 3. With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Socket NR-H or Ratchet (3/8” drive) & Socket NR-H Combination (Ref. Figure 4). The teeth of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). If desired, the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with a 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the “Vertical Adjustment” indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just has contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot contact the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6. The following instructions must be implemented for the maintenance and service of the Model RC-RES. When placing an order, please contact a local distributor with the following information (Model Name, Temperature Rating and Finish). Model: RC-RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162°F (72°C) or 175°F (79°C) ) 2-5/8 inch (68mm) or 3-1/4 inch (83mm) or 2-5/8 inch square (68mm), Order Separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. Standard Finishes Custom Finishes 2-5/8" Round, 140°F - - - - - - 3-1/4" Round, 140°F 2-5/8" Square, 140°F - - - - - - - 2-5/8" Round, 162°F - - - - - - - 3-1/4" Round, 162°F - - - - - - - Socket NR-H For use with a 3/8” drive ratchet (not included) Socket NR-H Plastic For use with a 1/2” drive ratchet (not included) Cap Remover RC OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org June 20, 2022 JD Mechanical Fire Inc. 82579 Fleming Way #D Indio, CA 92201 Re: Residential Fire Sprinkler Plan Review – VAN DER WERF FSS2022-0206 / 53405 HUMBOLDT BLVD, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 53405 HUMBOLDT BLVD PERMIT#: FSS2022-0206 DATE ISSUED: 6/20/2022 DESCRIPTION: VAN DER WERF CONTRACTOR: J D MECHANICAL FIRE INC HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.