Loading...
FSS2022-0220ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT SYMONS FIRE PROTECTION INC 9475 Chesapeake Drive san diego CA 92123 (619)588-6364 angela@symonsfp.com CONTRACTOR SYMONS FIRE PROTECTION INC 9475 Chesapeake Drive san diego CA 92123 (619)588-6364 angela@symonsfp.com OWNER National Mortgage & Land Co.81570 Carboneras LA QUINTA CA 92253 (619)588-6364 jlopez@andalusiacc.co m CONDITIONS Description: ANDALUSIA / FIRE SPRINKLER / BRES2021-0691 / PLAN 202 Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - TRACT HOMES Status: ISSUED Applied: 6/6/2022 ECON Parcel No: 764200071 Site Address: 58995 MARBELLA LA QUINTA,CA 92253 Approved: 6/7/2022 AHI Subdivision: 37790 Block: Lot: Issued: 6/8/2022 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $4,000.00 Occupancy Type: Construction Type: Expired: 3/25/2023 KHET No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: fire sprinklers for lot 50019 FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $167.00 $167.00 9/23/22 WEB13143 730178910 CREDIT 682025 ECON Printed: Thursday, April 13, 2023 2:33:37 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0220 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD HYRO KHET 8/16/2022 8/16/2022 APPROVED No leaks OVERHEAD ROUGH PIPING KHET 8/16/2022 8/16/2022 DISAPPROVE D SEE NOTES System was installed to "Old" plans and not the Revised Approved plans, as required. Several noted locations where too close to HVAC diffuser and Pendant-Light/Ceiling- fans DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $167.00 $167.00 9/23/22 WEB13143 730178910 CREDIT 682025 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $167.00 $167.00 6/8/22 WEB12060 637566355 20 CREDIT 682025 ECON Total Paid for FIRE FEES: $501.00 $501.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 6/8/22 WEB12060 637566355 20 CREDIT 682025 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 6/8/22 WEB12060 637566355 20 CREDIT 682025 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$517.00 $517.00 Printed: Thursday, April 13, 2023 2:33:37 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0220 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/6/2022 Etrakit Contractor fire application FIREAPPLICATION LOT 50019.pdf 1 DOC 8/16/2022 KOHL HETRICK Lot 19 - 8-16-2022 Insp Notes.pdf Lot 19 - 8-16-2022 Insp Notes.pdf 1 BOND INFORMATION OVERHEAD ROUGH PIPING LRO 9/7/2022 9/7/2022 DISAPPROVE D See Notes System was installed to "Old" plans and not the Revised Approved plans, as required. Sprinkler head K-factor number on the plans do not match on what was found in person. Replace high-temp head to match K-factor per the plans, move hot air diffuser accordingly to temperature of Sprinkler head. OVERHEAD ROUGH PIPING KHET 9/26/2022 9/26/2022 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH – ETRAKIT (1 DAY) PERMIT TECH BUCKET 6/6/2022 6/7/2022 6/7/2022 COMPLETE PARENT PROJECTS Printed: Thursday, April 13, 2023 2:33:37 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0220 A 10% REDUCTION WAS TAKEN OFF FOR CALC PURPOSES. STATIC PRESSURE IS CALCULATED AT 86.4 PSI PER COACHELLA VALLEY WATER DISTRICT. RESIDUAL SYSTEM WAS CALCULATED AT 77.7 PSI. ALL ROOMS ARE BASED ON 15x15 FT SPACING. CALCULATIONS ARE BASED ON THE WORST CASE SCENARIO TWO HEAD CALC ON 15 FT SPACING 4 FS1 A FS1 A 18 sq.ft. 16 sq.ft. 18 sq.ft. 7 sq.ft. 18 sq.ft. 23 sq.ft. HEAT ZONE HEAT ZONE PLAN TYPE 202 FLOOR PIPING PLAN 1" RISER IN WALL W/ INT. LABELED ACCESS PANEL 9 sq.ft. 17 sq.ft. DN 2'-6 UP 2'-6 DN UP 6'-6"6'-8"5'-6"2'-6"7'11'-3"2'-10"7'-6"10'-1"5'-6"11'-1"5'-6"4'-6"7'5'-4" 7'-6"8'-6"2'-6"3'7'-3"14'-6"7'-6"5'-6"13'-7"13'-6"7'-3" 12'-4"15'4' 6'-8" L L L L L J L L L L L L L L L L L L L L L L L L L L L L L L J LL L L L L L L L L L L L L L LL L L L L L L L L L L L L L L L L L L J L AL L LL LACAF J S/C S/C S/C TAG J L LL L L L VGFI L L L L L L L L J J J L L COURTYARD PATIO 12'-1" CLG. GREAT ROOM 12'-1" CLG. BATH 10'-1" CLG. MASTER KITCHEN 12'-1" CLG. PORTICO PWDR BATH 3 10'-1" CLG.CASITA 10'-1" CLG. PORCHENTRY 12'-1" CLG. GARAGEGOLF CART LAUN. 10'-1" CLG. SITTING 12'-1" CLG. BEDROOM 10'-1" CLG. MASTER BEDROOM 2 10'-1" CLG. HALL BATH 2 10'-1" CLG. CLOSET10'-1" CLG. WALK-IN COVERED 10'-1" CLG. 16'-1" CLG. DW GARAGE2-CAR WH A/C A/CA/C 10'-1" CLG.KITCHENETTE\A1;\A1; PWDR10'-1" CLG. \A1;\A1; Residential AREA 1 ?0.05gpm/ft² for 253ft² 5 B.O.R. 6 212 213 39 Hydraulic Information OCCUPANCY CLASSIFICATION Residential AREA 1 DENSITY (gpm/ft²)0.05 for 800ft² (Actual 253ft²) TOTAL HOSE STREAMS 5.00 TOTAL HEADS FLOWING 2 K-FACTOR 4.3 TOTAL WATER REQUIRED 29.22 TOTAL PRESSURE REQUIRED 53.249 BASE of RISER (gpm)24.22 BASE of RISER (psi)30.034 SAFETY MARGIN (psi)+33.145 (38.4%) NVICINITY MAP N.T.S. 2-CAR GARAGEBATH2GREAT ROOM OFFICESITTING 12 4 SPRINKLER SHUT OFF (ABOVE GROUND) 3/4" WATER METER EL= -3' TRANSITION FROM COPPER TO CPVC 50' OF 2" PVC PIPE 1 5' OF 1" COPPER (SWEEP) B.O.R. EL= 1' EL= -6' 4 1" COP LATERAL 8" MAIN UNDERGROUND DETAIL N.T.S. 6 5 ½" DRAIN FLOW SWITCH 1" CHECK VALVE TRANSITION FROM PVC TO COPPER PLUMBING SHUT OFF DOMESTIC PLUMBING REGULATOR 1" CPVC 300 PSI GAUGE 2 3 1" CPVC 1" CPVC EL= -9'5 GPM TO DOMESTIC PLUMBINGSprinkler Legend Symbol Manufacturer SIN Model Quantity K-Factor Type Size Response Finish Temperature Reliable R3511 F1RES30 5 3 Pendent ½Fast White 175°F Total = 5 Hydraulic Information OCCUPANCY CLASSIFICATION Residential AREA 1 DENSITY (gpm/ft²)0.05 for 800ft² (Actual 253ft²) TOTAL HOSE STREAMS 5.00 TOTAL HEADS FLOWING 2 K-FACTOR 4.3 TOTAL WATER REQUIRED 29.22 TOTAL PRESSURE REQUIRED 53.249 BASE of RISER (gpm)24.22 BASE of RISER (psi)30.034 SAFETY MARGIN (psi)+33.145 (38.4%) Hydraulic Information OCCUPANCY CLASSIFICATION Residential AREA 1 DENSITY (gpm/ft²)0.05 for 800ft² (Actual 253ft²) TOTAL HOSE STREAMS 5.00 TOTAL HEADS FLOWING 2 K-FACTOR 4.3 TOTAL WATER REQUIRED 29.22 TOTAL PRESSURE REQUIRED 53.249 BASE of RISER (gpm)24.22 BASE of RISER (psi)30.034 SAFETY MARGIN (psi)+33.145 (38.4%) Hydraulic Information OCCUPANCY CLASSIFICATION Residential AREA 1 DENSITY (gpm/ft²)0.05 for 800ft² (Actual 253ft²) TOTAL HOSE STREAMS 5.00 TOTAL HEADS FLOWING 2 K-FACTOR 4.3 TOTAL WATER REQUIRED 29.22 TOTAL PRESSURE REQUIRED 53.249 BASE of RISER (gpm)24.22 BASE of RISER (psi)30.034 SAFETY MARGIN (psi)+33.145 (38.4%) Hydraulic Information OCCUPANCY CLASSIFICATION Residential AREA 1 DENSITY (gpm/ft²)0.05 for 800ft² (Actual 253ft²) TOTAL HOSE STREAMS 5.00 TOTAL HEADS FLOWING 2 K-FACTOR 4.3 TOTAL WATER REQUIRED 29.22 TOTAL PRESSURE REQUIRED 53.249 BASE of RISER (gpm)24.22 BASE of RISER (psi)30.034 SAFETY MARGIN (psi)+33.145 (38.4%) 7'-0" 1 ¼"6'-6" 1 ½" SPACING 6'-0"1" MAX. HANGER CPVC PIPING APPLICATION 5'-6" SIZES 2"8'-0" HANGER LOCATIONS ARE TO BE PLACED PER MFRS. SPECIFICATIONS ¾" PIPE FIGURE 23 - CPVC HANGER CPVC DOUBLE FASTENER STRAP TYPE HANGER HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE FIGURE 22 - CPVC HANGERCPVC SINGLE FASTENER STRAP TYPE HANGER MINIMUM FASTENER SIZE ACCEPTABLE IS FURNISHED WITH THE HANGER AND IS THE HARDENED HEX HEAD SELF THREADING SCREW FIGURE 24 - CPVC HANGERCPVC DOUBLE FASTENER STRAP TYPE HANGER MINIMUM FASTENER SIZE ACCEPTABLE IS FURNISHED WITH THE HANGER AND IS THE HARDENED HEX HEAD SELF THREADING SCREW PIPING PLAN ¼"=1'-0" ALL 1" CPVC PIPING SCALE: 1/4"=1'-0"FIRE SPRINKLER & PIPING PLAN THE RECIPIENT OF THESE PLANS HEREBY ACKNOWLEDGES THAT ALL PLANS, DETAILS, SPECIFICATIONS AND/OR METHODS OF INSTALLATION CONTAINED IN THIS SET OF DRAWINGS IS THE SOLE PROPERTY OF SYMONS FIRE PROTECTION, INC., AND THAT ANY USE OF THIS SET OF DRAWINGS IS PROHIBITED AND IS A VIOLATION OF COPYRIGHT LAWS WITHOUT FIRST RECEIVING PERMISSION FROM SYMONS FIRE PROTECTION, INC.MARBELLALA QUINTA, CA 92253LA QUINTA FIRE DEPTDRAWING TITLEIRDATE12. 31. 22AFIRE SPRINKLER SYSTEMCSN PPROJECT:EAOCTC 05-10-2022DATE :PHONE.NT OCONTRACT WITH:RIFS1 LO OSNATIONAL MORTGAGE ANDLAND CO.IDRAWN BY: DEREK POWELLAUTHORITY HAVING JURISDICTIONREVISIONS-N R BYIT O FSL-IC OCT(760) 777-7125N MSCALE :OO MARKFIC16/C10RT Y-TEF-NEEEF20-0577TJOB NO. A ANDALUSIA PLAN 202EERR DESCRIPTIONASHEET NO. I 682025AS NOTEDI9475 CHESAPEAKE DR, SAN DIEGO, CA 92123 (619) 588-6364 WWW.SYMONSFP.COM CA. C10 & C16 LIC. #682025 RS,CCOPDEXP. DATETNN - 1. THIS IS A WET PIPE SPRINKLER SYSTEM DESIGNED & INSTALLED PER CRC 313.3, CFC 2019, AND/OR NFPA 13D (2016 EDITION) AND THE LA QUINTA FIRE DEPT. 2. ALL PIPE AND FITTINGS ARE NEW, UL LISTED, AND CONFORM TO THE STANDARDS OF NFPA 13D 2016 EDITION. 3. PROVIDE ELECTRICAL BELL FOR LOCAL ALARM. WIRING BY OTHERS. SIZE AND LOCATION ON PLANS. WATERFLOW ALARM REQUIRED TO BE CLEARLY AUDIBLE IN ALL LIVING SPACES OVER BACKGROUND NOISE WITH ALL INTERVENING DOORS CLOSED. 4. STORAGE IN ATTIC & CRAWL SPACES NOT ALLOWED WHERE NOT PROTECTED. 5. GARAGE & MECHANICAL ROOMS TO BE SPRINKLERED W/175* HEADS 6. SPRINKLER HEADS OMITTED FROM BATHROOMS AND CLOSETS THAT MEET THE CONDITIONS OF 8.3.2 & 8.3.3 NFPA 13D 2016 EDITION. 7. - INDICATES HYD. CALC. REFERENCE POINT. 8. DRILLING OR NOTCHING OF STRUCTURAL MEMBERS SHALL BE IN STRICT ACCORDANCE WITH CBC & CRC - (2016) 9. ALL PENETRATIONS THROUGH FIREWALLS & CEILINGS BETWEEN ATTACHED GARAGE & RESIDENCE WILL BE SEALED IN AN APPROVED MANNER TO MAINTAIN INTEGRITY OF THE FIREWALL. 10. MAINTENANCE BOOK & 1 HEAD (UP TO 3 OF EACH IF REQUIRED) OF EACH TYPE USED PLUS HEAD WRENCH SHALL BE PROVIDED IN SPARE HEAD CABINET LOCATED NEXT TO RISER. 11. PIPE HANGERS SHALL BE IN ACCORDANCE WITH NFPA 13D & THE WRITTEN INSTRUCTIONS OF THE PIPE MANUFACTURER. 12. ANY SPRINKLERS THAT HAVE BEEN PAINTED OUTSIDE OF THE FACTORY SHALL BE REPLACED WITH A NEW LISTED SPRINKLER PER NFPA 13D STANDARDS. 13. EXTERIOR EXPOSED STEEL PIPING PAINTED.(BY OTHERS) 14. CONTRACTOR/OWNER IS RESPONSIBLE FOR INSTALLATION OF UNDERGROUND. (CHECK WITH SYMONS FIRE PROTECTION FOR PROPER SIZING.) 15. SMOKE DETECTORS ARE TO BE INSTALLED IN ACCORDANCE WITH NFPA 72, NATIONAL FIRE CODE (AND TO BE INSTALLED BY OTHERS.) GENERAL NOTES RESIDUAL PSI AT SOURCE STATIC PSI: SYSTEM FLOW REQUIREMENTS: REMOTE AREA 1 GPM FLOWING W/ 4.3 K-FACTOR FLOWS PER HEAD = SPRINKLER FLOW REQ. @ 1HD = SPRINKLER SYSTEM DESIGN CRITERIA & FLOW REQUIREMENTS COCHELLA VALLEY 1HD = PHONE NUMBER: CONTACT: 15' SPACING REL. RFC43 CONCL. FLAT 7'-6 MAX OFF WALL 96.0 PSIDATE OBTAINED: GPM FLOWING W/ R. MONTEL RESIDUAL PSI AT BASE OF RISER (SIN) # RA0612 WATER FLOW INFO BY: DESIGN SPRINKLER = 12.0 GPM @ 7.8 PSI 7-28-21 760 398 2661 SECTION 'A'SCALE 1/4" = 1'-0"SITE PLAN SCALE 1" = 240'-0"AS BUILT