Loading...
FSS2022-0232ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT RESIDENTIAL FIRE PROTECTION DBA ON GUARD 6438 ARVILLE ST LAS VEGAS NV 89118 (702)966-8021 VanesaH@ONGUARDF P.COM CONTRACTOR RESIDENTIAL FIRE PROTECTION DBA ON GUARD 6438 ARVILLE ST LAS VEGAS NV 89118 (702)966-8021 VanesaH@ONGUARDF P.COM OWNER BEAZER HOMES 310 COMMERCE IRVINE CA 92602000 0 (702)966-8021 CONDITIONS Description: CANTERA / FIRE SPRINKLERS / BRES2022-0505/ PLAN 3 Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - TRACT HOMES Status: FINALED Applied: 6/9/2022 ECON Parcel No: 766140012 Site Address: 58100 ARAGON WAY LA QUINTA,CA 92253 Approved: 9/21/2022 AHI Subdivision: TR 31249 Block: Lot: 37 Issued: ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 2/7/2023 KHET Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Thursday, April 13, 2023 2:55:47 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0232 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING LIN 11/2/2022 11/2/2022 DISAPPROVE D SEE NOTES LEAK IN HALL AT BEDROOM 2 OVERHEAD HYRO LIN 11/2/2022 11/2/2022 DISAPPROVE D SEE NOTES LEAK IN HALL AT BEDROOM 2 OVERHEAD ROUGH PIPING LRO 11/9/2022 11/9/2022 APPROVED OVERHEAD HYRO LRO 11/9/2022 11/9/2022 APPROVED DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE FAILED OR ADDITIONAL FIELD INSPECTIONS (EXCESSIVE) EACH 101-0000-42421 0 $175.00 $175.00 1/19/23 WEB14102 800079628 CREDIT 950378 ECON FIRE FAILED OR ADDITIONAL FIELD INSPECTIONS (EXCESSIVE) EACH 101-0000-42421 0 $175.00 $175.00 12/19/22 WEB13870 773150583 CREDIT 950378 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $167.00 $167.00 9/22/22 WEB13125 729295386 CREDIT 950378 ECON Total Paid for FIRE FEES: $517.00 $517.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 9/22/22 WEB13125 729295386 CREDIT 950378 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 9/22/22 WEB13125 729295386 CREDIT 950378 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$533.00 $533.00 Printed: Thursday, April 13, 2023 2:55:47 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0232 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 2/7/2023 KOHL HETRICK 2-7-2023 - email.pdf 2-7-2023 - email.pdf 1 DOC 11/3/2022 LUCERO INIGUEZ Cantera Lots 35-37, 53 110222.pdf Cantera Lots 35-37, 53 110222.pdf 0 BOND INFORMATION FIRE FINAL**KHET 12/28/2022 12/28/2022 NOT READY FIRE FINAL**KHET 1/17/2023 1/17/2023 DISAPPROVE D Fire sprinkler riser is showing a residual flow of only 35 psi while all other lots are flowing about 50 psi (40-45 is common for the 3/4" WM in this pressure zone). Checked all valves and valve sizes. Contractor will need to investigate. FIRE FINAL**LRO 1/27/2023 1/27/2023 NOT READY No Fee/SEE NOTES Contractor let me know onsite that the home is not ready. Currently tried to fix water pressure by doing what he could do before tearing up the street, was unable to do so. Will be pursuing actually tearing up the street to figure out what the issue is with the UG Piping. No fee's. FIRE FINAL**KHET 2/7/2023 2/7/2023 APPROVED SEE ATTACHMENTS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH – ETRAKIT (1 DAY) AARON HICKSON 6/9/2022 6/10/2022 6/10/2022 COMPLETE ON HOLD UNTIL DWELLING PERMITS ARE ISSUED PARENT PROJECTS Printed: Thursday, April 13, 2023 2:55:47 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0232 1 Hetrick, Kohl@CALFIRE From:Hetrick, Kohl@CALFIRE Sent:Tuesday, February 7, 2023 1:25 PM To:'Grant Brinkman'; OnGuard Alfredo; 2020 - Pete Hernandez; Gavin Percy; CVWD - Tommy - Dev Super Fowlkes; Mauricio Padilla; Jim Griffin Subject:RE: Cantera lot 37 Good day, I managed to stop by the development this morning at about 10:00 am. I flexed the main drain valve on the neighboring house and observed 95psi static with 50psi residual. I then flexed the main drain valve on Lot 37 (FSS2022-0232) and it showed 92 psi static and 40 psi residual. This flow pressure will be accepted for this lot. I walked the house and confirmed that the project can be final approved by Fire. I have updated the Etrakit system appropriately. CVWD – it is a concern that multiple neighboring lots show a consistent higher flow and sporadic lots, such as this one, present with a much lower residual pressure. The fire sprinkler riser is just a means to sample the available water supply static and residual pressures with any consistency in a particular project or zone. It is not a method for determining adequate flow/pressure for a particular hydraulic calculation, as it does not adequately identify or provide the system design flow of 31gpm. Once a developer has made all reasonable test and checks of their water system on the downstream side of the water meter, consideration for the water meter assembly should be handled as it was. But if still presenting with a low residual issue, increased confidence should be noted of the concern for the service line being impacted in some way and therefore needing to be corrected (service cutout not complete / pinched line). If more low residual flows less than 40 psi come up in this project, further investigation should be warranted as necessary. Respectfully, KOHL HETRICK Fire Safety Specialist / Office of the Fire Marshal City of La Quinta CAL FIRE/Riverside County Fire Department Desk: 760-777-7074 | Mobile: 760-409-5109 Inspection Hotline: 760-777-7131 78495 Calle Tampico, La Quinta, CA 92253 kohl.hetrick@fire.ca.gov | www.rvcfire.org Sch: Mon-Thurs LeadershipCompetenceIntegritySafetyCustomer Service The Office of the County Fire Marshal is committed to facilitating fire and life safety solutions by empowering its employees to serve our community through innovation and partnership. From: Grant Brinkman <gbrinkma@beazer.com> Sent: Friday, February 3, 2023 3:03 PM To: Hetrick, Kohl@CALFIRE <Kohl.Hetrick@fire.ca.gov>; OnGuard Alfredo <alfredo@onguardfp.com>; 2020 - Pete Hernandez <p.hernandez@2020ph.com>; Gavin Percy <gavin.percy@beazer.com>; CVWD - Tommy - Dev Super Fowlkes <TFowlkes@cvwd.org>; Mauricio Padilla <mauricio.padilla@beazer.com>; Jim Griffin <jim.griffin@beazer.com> Subject: Cantera lot 37 Warning: this message is from an external user and should be treated with caution. Kohl, here is a run down of we have tested Camera main line from street to house - clear Bypassed fire riser and did flow test - 90 psi static and about 35 psi with flow test valve open. Built a portable flow test valve with guage and installed directly to water meter - 90 psi static and about 35 psi with flow test valve open. CVWD came out and changed out meter - 90 psi static and about 35 psi with flow test valve open. CVWD checked pressure before and after meter. 90 psi Please let me know if need additional info. Thanks and have a great weekend Grant Brinkman Construction Manager Senior Beazer Homes - Cantera 80-270 Vera Cruz Court La Quinta, CA 92253 Cell: 714.720.2991 78-495 Calle Tampico, La Quinta CA 92253 Main: 760-777-7000 Direct: 760-777-7074 PAGE _____ OF _____ PERMIT/CASE#: NOTICE NO: FACILITY NAME: DATE: FACILITY ADDRESS: CONTACT: The items below are in violation of or shall meet additional requirements of one or more of the following:  CALIFORNIA FIRE CODE __________________  NFPA STD. ______________  CALIFORNIA BUILDING CODE _____________  CCR TITLE ______________  LA QUINTA MUNICIPAL CODE _____________  OTHER ________________ The listed violations/requirements shall be corrected immediately. A re-inspection will be conducted on or after ______________________________ 20____. FAILURE TO COMPLY MAY RESULT IN LEGAL ACTION AND/OR SIGNIFICANT DELAYS FOR APPROVAL. Received By: __________________________________ Signature: _______________________________________ Fire Inspector: _________________________________ Radio I.D.: _______________________________________ IF YOU HAVE ANY QUESTIONS OR NEED ADDITIONAL INFORMATION, PLEASE CALL 760-777-7074.