Loading...
FCMP2022-0024 Sol Terra Centre Courts Plan 4a u�tt Project Details PROJECT NUMBER ` =�w City of La Qu i nta FCM P2022-0024 MoFT�• . Description: SOLTERRA - PRODUCT 2 - MASTER SPRINKLER PLAN - PLAN 4 Status: APPROVED Type: FIRE CONSTRUCTION MASTER PLAN (WEB) Status Date: 1/9/2023 Subtype: FIRE SPRINKLER MASTER PLAN Applied: 7/21/2022 Address: 47260 ADAMS ST Approved: 8/28/2022 City, State, Zip: LA QUINTA,CA92253 Closed: Project Manager: Expired: Details: Pr DAYS REVIEWS III ACTIONS INSPECTIONS CONDITIONS ADDITIONAL SITES CHRONOL NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT RESIDENTIAL FIRE PROTECTION DBA ON GUARD 6438 ARVILLE ST LAS VEGAS NV 89118 (702)966-8021 VanesaH@ONGUARDF P.COM BILL TO RESIDENTIAL FIRE PROTECTION DBA ON GUARD 6438 ARVILLE ST LAS VEGAS NV (702)966-8021 VanesaH@ONGUARDF P.COM CONTRACTOR RESIDENTIAL FIRE PROTECTION DBA ON GUARD 6438 ARVILLE ST LAS VEGAS NV 89118 (702)966-8021 VanesaH@ONGUARDF P.COM OWNER THE CENTER ON ADAMS, LLC 2 PARK PLAZA SUITE 700 IRVINE CA 92614 (702)966-8021 DK@VERTICALINTEGRI TY. N ET •' ii • Printed: Friday, April 21, 2023 11:51:15 AM 1 of 3 CENTRALSOLIARE a u�tt Project Details PROJECT NUMBER ` =�w City of La Qu i nta FCM P2022-0024 MoFT�• CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY FIRE PLAN REVISION 101-0000-42420 0 $175.00 $175.00 1/23/23 WEB14122 801973357 CREDIT 950378 ECON SUBMITTALS FIRE STAFF - PER HOUR 101-0000-42420 0 $250.00 $250.00 8/29/22 WEB12907 715139760 CREDIT 950378 ECON Total Paid for FIRE FEES: $425.00 $425.00 RECORDS MANAGEMENT FEE - 101-0000-42416 0 $21.00 $21.00 8/29/22 WEB12907 715139760 CREDIT 950378 ECON MAJOR Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00 TECHNOLOGY 502-0000-43611 0 $5.00 $5.00 8/29/22 WEB12907 715139760 CREDIT 950378 ECON ENHANCEMENT FEE Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES DATE DATE RETURNED REVIEW TYPE REVIEWER SENT DATE DUE DATE STATUS REMARKS NOTES DATE 1ST FIRE (2WK) KOHL 7/21/2022 8/4/2022 8/28/2022 APPROVED SEE ATTACHMENTS HETRICK 1ST PERMIT AARON 7/21/2022 7/22/2022 7/25/2022 COMPLETE TECHNICIAN (1DAY) HICKSON 2ND FIRE (1WK) KOHL 1/9/2023 1/16/2023 3/6/2023 APPROVED SEE ATTACHMENTS HETRICK Printed: Friday, April 21, 2023 11:51:15 AM 2 of 3 CENTRALSOLIARE a u�tt Project Details PROJECT NUMBER ` =�w City of La Qu i nta FCM P2022-0024 MoFT�• r Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 7/21/2022 Etrakit Contractor 1ST SUBMITTAL THE CENTRE CLUSTER 1 HYDRAULIC CALCS PLAN 4 CALCS.pdf DOC 7/21/2022 Etrakit Contractor 1ST SUBMITTAL PLANS THE CENTRE CLUSTER1 PLAN 4 SUBS.pdf 1ST SUBMITTAL DOC 7/21/2022 Etrakit Contractor MATERIAL SPEC SHEETS 00 MATERIAL 1 CURSHEET.pdf W/FLOW TEST 01 - THE CENTRE @ LA DOC 1/9/2023 Etrakit Contractor Asbuilt Revisions QUINTA PLAN 4 - HYD 1 CALC - D1.pdf 00 - THE CENTRE @ LA DOC 1/9/2023 Etrakit Contractor Revised Hydraulic Calc QUINTA PLAN 4 - FS 1 PLAN - D1.pdf DOC 8/28/2022 KOHL HETRICK FCMP2022-0024 - COA FCMP2022-0024 - COA 1 LETTER.pdf LETTER.pdf FCMP2022-0024 - PLAN FCMP2022-0024 - PLAN DOC 8/28/2022 KOHL HETRICK 4 - PROD 2 - APPROVED 4 - PROD 2 - APPROVED 1 PLANS AND CALCS.pdf PLANS AND CALCS.pdf FCMP2022-0024 - PLAN FCMP2022-0024 - PLAN DOC 3/6/2023 KOHL HETRICK 4 - PROD 2 - REVISED 4 - PROD 2 - REVISED 1 PLANS AND CALCS - PLANS AND CALCS - APPROVED.pdf APPROVED.pdf Printed: Friday, April 21, 2023 11:51:15 AM 3 of 3 CENTRALSOLIARE SENJU SPRINKLER CO., LTD. RealtlurblLutlFrea Flal Cym.—d SpplRkMr. V�IaNG' GENERAL INFORMATION: PLAN4-THECENTRE"CLUSTER" PLAN No. • eDa ev�riwv 3110 IpECL ARWO CF' 7SWtl HOLE STRAP plpErofiEaa„o pee wnp A f'vnoosc RGRI J VO�I �tWEE- (N.T.sJ J /J �� JJ 01� rypTE pL�p�p�ry�rytl���g�Cpy�q�� NAT11Nsl1L4TION TG PREVENT FREEZING. GUARD IgN R-309'TICKNESS. ��� Z�� I K ddd SIZE g a s,y •43 6 i 111T, U9&&� €�'$R6669 Of s3g € sseg$�€$tl" „ay� 88 EYyiitldfb€� a y aR�yM84 N�N 5f �gac 88E� a 9 Pentlent. Model: RC-RES. R-Faebr: d.9. SIN: SSad80 .e....ar.,..wx,ae.°aw.1.e"va.,..•e• 1. m GENERAL DESCRIPTION I. oR Ua xre ..,,r..�xrwtea. OCCUPANCY-R-3/U CONSTRUCTION TYPE V-B wcooscae�y 1 _ — Z ewea+wa.oa..y. za,z,z. NP. OF STORIES. 2 ON GUARD FIRE PROTECTION Gib: B503]8 H PEcraMp WB�rw T x .. ° awn, r..,x�,.--._...x1..•.a...x..,...,,,, C7 ceurxg t rra B A6cco CnSpaAko-oFF (NT6i cP"vc rein°N�F�u{sao ei 1) DROP AND INSULATION DETAIL VICINITYMAP N.T.S. HANGERSPETER20ACING FIRE NTS ,rot aro°•° .,. sax run ., xoozw.rprr°.. D A BLAZEMASTER 2000 PIPE o sp QE rlazl PE LEes1-11opt OR[ATEH THAry loops N. arassrke ° ® p+�ra+sE x d� 1w im,o ,:: ennrR n".rex..u.a�er°...avw eey.aersx N.a".vow wn."•a xanN a.rwmwn.a..namr. »a. II2 ROa in.�a a OS rn. Ae ESPC20 o) ne(Nm) MG) �xrvEa nacxacxvuw All individual dwelling neanmmeol m•n.ww pe. aeaw,a..m.»amwvwwm.n m.w •+r.an,v1*a«a.near,m p.•wawl.v.»•. (t.e) a"(sx.o)A, R.0 p[ L[ss THAN11c icR[ai[R THSry laopd aM1ud lY r x valve t�h tcomrols the nma ,re• a I v "•..° wnron. - 2' (a0.0) (2.1) water �PPIY for ww.o rre FIND fa the OESIGN CRITERIA.e��avrocaroraeva»ceae.w.a earoxr,ew.m".. enp LO°an0" rowan. mn xroy aer ara>a» (50.0) (?a) 2' (65.U) (z ]) IO I K N. HMO individual unit. ro' wx�a.r.n 4 5 o�eme..mulo- °ereea tiu e.w" mrnnavwa xv.aa aro wwawgvv..e,.acxrc,aw..ero 1-1—..m.Dame.waaexm11wmm»wamey»rovrumroueay mmamw.unvin.aanear c s•vnaa. •,...«.«.".a.an ro.n. .p•,wro»..a.a.nxTaal>ePa 711111T ODETAIL ..ma,.«ay.e.,ro„er.v"r,wm,aaa.,e,or«n.,.wam�e �. aw."a.a,are•va A rvvoparvT RISER AND UNDERG, W/1%"^�MCE6FITERR GENERAL NOTES: .. i Rn4iw"n mewnwro.e.m•ro «w•ro. «. n."e rM s.roo"nw m. rney,aw.aw�w.ma+,. va ..e..,«u. a.,..,rewa,"«a..e-r.wv c"�.ew. coon (n) on(.)(elm HANGER ACING DEFAIL(NTS) MINIMUM gSTANCES FOR ORDINARY AND INTERMEDIATE HEADS DECU1. SYSTEM, HYDEAULIC MEDESIGNEDTLATION,6WTHTHE ING DOCLMENTAND ARE DESIGNED TOCOMPLYW1THTHE2016NFPA 130. 2016 2. ALL PIPE AND FITTINGS SHALL BE TYCO BLAZEMASTER CPVC SIR EDANDULLISTED FORUSEINFlREPROTEOrCN SYSTEMS. tl 6 eree,".ro. a.uwrvam,ro.rerwaa.". ,.�e..ae... ^ .«aai.m «,«y ,.",.,. arc.rc.ro.iaev<ww« „ery ero.er HEAT SORCE ORDINARYTEMP INTERMEDWTE TEMP. .qLL PIPE DIMENSIONSARE CENTERTOCENTER. PIPE TO BE HUNG USING APPROVED METHODS PER NFPA 13D. i - ,ap..r se.•vr ro n.,. ..aa«. a.s...m LLUMP .ALL .ALL PIPING SHALLBETESTEDFORLEAKAGEATNORMALSYSTEM OPERATING WATER PRESSURE. SEE NFPA 13D F a,".m•rmi..m.r,,.w,r.merroealwavrn r+.»w,ur«s..wrwa.aen. 6. ALL PIPE IN ATTIC SPACES SHALL BE SURBINENTLV COVERED WITH INSULATION TO PREVENT FREEZING (BY OTHERS). 7. SPRINKLER HEADS ME ORDINARY TEMPERATURE AND THEREFORE _ aamxux.. m.•ronnw„uwenwarw. w.ueay.r. wm aamax.•.eo..ma«nva.w«w.erowae nTrt UST BE SUFFICIENTLY SPACED FROM HEAT PRODUCING DEVICES AS FOLLO PEFIREPLACES FIREPLACES: 80"FROM FRONTgN038'FRCM SIDES. �F - xee hoot aw,ex.vnl».mRalsous,pxanmanwymwpeuwnapmaa•awwra wwu eamwr a ru» aeaE& aw m w awwn a e r"a.n... m., ew ro aaU.a _ ry ° "^ • •^° _ ^'nroeww "'tl®"'°'"^ awero"maa..wuvv. AI bvancefa�Fncdo Low Fim ak TFPBazer,vabr VC n . in 'c r CP Fillin 5¢e In. / 1" 1Yv' 1X' 2' 2X 3" Tee br 90 3 5 6 8 f 0 12 15 Elbow 90 q 5 fi ] 9 12 13 Elbow45 1 1 2 2 2 3 4 Coupling 1 1 1 1 1 2 2 Tee Run 1 1 1 1 1 2 2 exwmvMe» X2 (5.1am21 sa sprinkdkrs seal nett I relq.—, drones dose:q linen dose:q uee by B.3.2tnrougn 8.3.e. entl low. and panties nm me .1111. LIGHTVFIMURE OSO OFg99WPCE 1'-0" 0'8" g rye entl) or Wr Pere n. R302.6 WdIin lGe purl lire se do he garage andlor carport shall be separa II required by-Ib rME.6. Opening. in garage walls shall n sevtlon r3M.5. Tors does not a II n ne ad ompN wtl provision pu,ed 11mg ova s,d are perpandreuar tot jacen walling unb I. A eeparetion is nm required between the dwelling unit and a caport, pmvidetl the carport is tirelyepen on two or moresitles end [here ere not enclosed areas above. RA NGEORWALLOVEN:iB"FROMFRONTANDSIDES. FILING DIFFUSERS:24" FROM OUTSIDE EDGES. HORIZOMALgFFLSERS: 24"FROMEDGE AN03fi'FROM FRONT. E%POSED LIGHT FIXTURES: B'FROM EDGES.. .HEADS SPACED AT S X 16 SHALL HAVE THE FOLLONING LLOINIMUM: q^ MINIMUM FROM WALL. 9'Mq%IMUM OFF MY HEADS. LS. 6 MINIMUAXIMUM BETWEEN HEADS. .'MINIMUM BETWEEN HEgDS.� HE SPACED AT ED'X20' SHALL HAVE THE FOLLOWING ALLOWANCES -MINIMUM FROM WALL iG MAXIMUM OFF ANY TWO WALLS , qLL SOFFITS OVER 30' IN W OT1 ARE TO BE PROTECTED WITH SPRINKLER COVERAGE UNDER SOFFIT. 10. ALL STREET WATER CONNECTIONS ARE FLUSHED AT THE GARAGE {�y Z Q O 3qe �« '�3 Sm L w ,yw 3 wm.zreaal"">,..e.ex,.o• _ .raga insdlWtion spwMratians sM1al onN apply for tM1e insglatbn of ul listed Blazamaslar CPVC pipe and Nin sin kler temipn NFPA 13D entl NFPA 13R. Blazemasta rM frain 9 9emges requiring spdn pro per pipes gs or gang in6meu.... in allation Requiremen5: Memion: &ezeaNsler pipe entl fMings shell be in9eled wnceekd behhd Pmtemion consi9ing me imamof onelaveraf 3l6 tM1rek ovoeumorh tM1reN elvwoatl. m.m.maaa elaaFrsacl. s,v.e..•,wn.nw.ve.a w.ro to mv:amve•s aem.w..m.e.x easy Ip eNe.lm,'wrwenec e a m•ss.a,cv".....m ^••rm.naw over r °wawrca,.oreoevW w,.awvau..e.W N apHmreesveNmpyay,w»Ooanree" 77=7 (1�bM1 zreaxof,neaapaw tloea no[exmetl LX2 (21 m21. TM1e vela entl whinge are auRamtl MN noncombudide or tiro'netl<ombuatibb rreter'ub as tlefinetl In TABLE R302ADWELLINGIGARAGEANDIO ERARATON TASEPARATION SMATERIAL T, RISER BY(21 PROVIDE TIEPLUMBAINER.ING TRgCTOR AND IN ADDITION ME PROVIDED WT1gSTRgINER. _ rw.ro"=.r,•.,,,axra.,xoe"ina. xl"MMewaaMms - Wee"W soars e•xve ai ""`"'r .eo .vv or•ma•. ..a.r.«ea.mrpuw••axopv " ^°� "x "'� aA brinkers nm be,egkurreain aemd,ea garages, open atmcnea ranafn, craw a, ana omerconceaka parents, calpons win no tnarare na gypsum FromtM1aresidancetoth—k. o s an or equival.ntapplietl to [he garege side. From the nabltade rooms above garage or Not less roan SR'rype X9YPsum beaN or carport. equivalen 11. PENDENT SPRINKLERS SHALL BE LOCATED 3fi AWAY FROM CEILING FANS AND LIGHT FIXTURES. 12. PER NFPA 13D 20161N ALL CLOSETS, INCLUDING THOSE CLOSETS HWSINGMEOHANIO EOUIPMENT,T ARENOLARGERTHAN—P IN SEE ASINGLE SPINKLER AT THE HIGHEST CEILING SPACE IN THE ,,pL�,T1011 no x A lare.imn . wero,a•.mmmarw,.rayea saw":„".aa .mwrmnnmA l» probctio¢ dNe buJtlrng m emrancexlezi» Not kss tM1an X" mboaN er gyp.0 for by LOSET SHALL BE SUFFldENT WTHCUT REGUARO TOOBSTRUCTIONS. G16 S ra'� ( L cast coon sod sepeM ng req aired tM1k sod on euvalen[ uaraFles located lesstnan 3fem fromadwyll ng Not less tM1anX aypsum hoaM or he same bt emmqurvalem a�d dtothe mefordda eftheaxtador 13. PER NFPA 13020165.1.13, SPARE SPRINKLERS SHALL NOT BE REOgREO. m•w. .•e r.,n.0 Sructure(s)wM. ngtbor/ceing asremlras Ilathata homes Foq N N n wrM urNvci.rl. • a«-ro-axx..nx.pa,».1 ref E I ��, �:/ wv O M 0 U ADoREaa s9 �ij ide County Fire R1Ve�APPROVo�a iU ~ I I r y LL�O���TEE��33r4����,� A4i, •. _= .A "7z hJ '� FLOW TEST LOCATION T SEE FLOW TEST INFORMATION ----- -- ---- - STATIC B9.6pa-10%-80.65psi nBnt La Qu nta Office of the Fire Marshal BY: Kohl Hetrick ^­.,­ FIRE SAFETY SPECIALIST 03/06/202323746PM TM1eapproval of plansantl specRwtwns does not d pe�milh delremammss on orfaulry W gQ �V Q yQ°pq �9� w ~ �~� ¢O —Z a W _ aK $LLI $tea °W~ W-L nsas (sn ea.y p.Nl _ yq man m v"m rmm u - ` sw, ..." :;e a a,a„ RESIDUAL: 80.0-10%=T2.Opsi FLOW-2,BEOOpm =J I d6FI t ELEVATION=68 Ft rtli I 1. t0 H - I —_ N aw v eel role 24 or env Local d' Cnstrucfon shall reman pe ss bk and expasetl for'nspecfan purposes approvetl by the Fre DePadment. untlTFEE PERMIT #-FCMP20220024REV1 wH W'? egg aD AQ a ^� 6 "gag wa.e memrew+ne•ee+.s s.wroaa•rc wr•rwe.•.®a, er.•rem•w.mic v. =w1"e. ax rea..a ea..•. wnawe ®,mmwr*u m• GENERALNOTES crxc. zam T.HARGROVE .,, °. r..w°..,x"1.•ye'"ea•.a aea.w r.,. ..M a... . � _ __ ` e I a T I P .... 7118=2 EAS NOTED .... :.... y LOT3 SITE MAP FP1 OF 2 7'6'-11 5'-8 10'-1 5'4'11'-15'5'10'-15'-2 3'-11 12'-5 12'-58'-48'-57'-2UP ¾ x 10'-0TO 2ND FLR.TO 2ND FLR.UP ¾ x 10'-0PWDR26.81ft²¾2'-5¾ 1'-2 1'-1¾¾ ¾ 5'-6 1' ¾ 10'-7 ¾1'-10 ¾ 5'-10 6" 111'-9¾2'-5¾4'-9¾4'-6¾ 5"¾11'-1¾ 4'-6 8"¾¾1'-4¾9'¾7'-3¾ 6'-8¾2'5"¾3'-1¾¾2'-9¾6'-6¾ 10'-1 152 150 2-CAR GARAGE9'-0 CLG. 9'-0 CLG.KITCHEN GREAT ROOM9'-0 CLG. 9'-0 CLG.ENTRY COVERED PATIO9'-0 CLG. PANTRY 6.37ft²HEAT ZONE9'-0 CLG. FAU A.A. 5'-8 3'-9 3'-8 3'-4 9'2'-3 2'-10 6'2'-107'-111'-69'-66'4'-10 3'-25'-11 6'-26'-2 7'-4 1'-57'-27'-21'-912'-42'-75'-45'-3REMOTE AREA #1 20'x20' SPACING 16'x16' SPACING REMOTE AREA #2 REMOTE AREA #118'x18' SPACINGTO 1ST FLR.DN ¾ x 10'-0UP ¾ x 3'-0TO FAU BA. 2 PRIM BA. 9'-0 CLG.11.23ft²BDRM 3 9'-0 CLG. 9'-0 CLG.13.07ft²43.97ft² 10.82ft² 9'-0 CLG. 9'-0 CLG. W.I.C. W.I.C. 16.45ft² BA. 3 16.66ft²DN ¾ x 10'-0TO 1ST FLR.102 201 101 1'-5 ¾¾1'1'-2¾2'-5¾2'-2¾2'-3¾¾7'-8¾ 3'-5 ¾ 7'-4¾1'¾3'-9¾ 7'-6 ¾1'-7¾ 4'-7 ¾11'¾1'-5¾¾2'-6¾ 8'-4 3'-7¾¾4'¾ 7'-3 ¾5'¾ 13'-9 ¾4'-8 ¾ 12'-8 ¾ 5'-6 ¾2'-3¾1'-45"¾1'¾1'-7 258 250 254256 252 LAUN. BDRM 4 9'-0 CLG. 9'-0 CLG. BDRM 2 9'-0 CLG. HALL 9'-0 CLG. PRIM BDRM.9'-0 CLG.3.07ft²SHADOW AREA3.22ft²SHADOWAREA 9'1'-39'9'1'-39'BDRM 2HALLBDRM 1 GREAT ROOM 2-CAR GARAGE Hydraulic Information Remote Area 1- 18'x18' SPACING OCCUPANCY CLASSIFICATION Residential DENSITY (gpm/ft²)0.05 for 648.00ft² (Actual 80.12ft²) TOTAL HOSE STREAMS 30.00 TOTAL HEADS FLOWING 2 K-FACTOR 4.9 TOTAL WATER REQUIRED 64.06 TOTAL PRESSURE REQUIRED 78.261 BASE of RISER (gpm)34.06 BASE of RISER (psi)44.265 SAFETY MARGIN (psi)+2.218 (2.8%) Hydraulic Information Remote Area 2- 20'x20' SPACING OCCUPANCY CLASSIFICATION Residential DENSITY (gpm/ft²)0.05 for 400.00ft² (Actual 127.60ft²) TOTAL HOSE STREAMS 30.00 TOTAL HEADS FLOWING 1 K-FACTOR 4.9 TOTAL WATER REQUIRED 51.02 TOTAL PRESSURE REQUIRED 60.166 BASE of RISER (gpm)21.02 BASE of RISER (psi)38.282 SAFETY MARGIN (psi)+20.337 (25.3%) 1 1 1 1 1 1 1 1 1 11 1 1 11 11 1 1 1 AS NOTED FIRE SPRINKLER PLANS NV LIC: 61307 - CA LIC: 950378 http://www.onguardfp.com 6438 ARVILLE STREET LAS VEGAS, NEVADA 89118PHONE (702) 966-8021 - FAX (702) 987-1174 NV Fire Marshal LIC: G-537 & JG-85 FP2 OF 2 22-20-20 T.HARGROVE 7/18/20224132TITLE: DRAWN: PROJECT NO:PROJECT NAME:PROJECT ADDRESS:SHEET: SCALE: DATE:DATEREV. BYREVISIONSZ.R.AS- BUILT FIELD REVISIONS1/9/2023VERTICALTRACT 37359LA QUINTA, CA 92253INTEGRITYPLAN 447340 POPPY LANELOT 129SOLTERRA@THE CENTRE COURTSON L ICT LICENSE NO. C-16RE A RR ETF NTAOTC T RFORCLASSIFICATION S O F TC OF950378 OA II E C N IPASECOND FLOOR SCALE: 1/4" = 1'-0 FIRST FLOOR SCALE: 1/4" = 1'-0 SECTION VIEW SCALE: 1/4" = 1'-0 RISER LOCATION PROJECT CONRTACTOR:Sprinkler LegendSymbolSpacingManufacturerSINModel K TypeSizeFinishTemp.Qty.16'x16'Senju Sprinkler Co., LTDSS8464RC-RES4.9Pendent½White205°F716'x16'Senju Sprinkler Co., LTDSS8464RC-RES4.9Pendent½White162°F818'x18'Senju Sprinkler Co., LTDSS8464RC-RES4.9Pendent½White162°F720'x20'Senju Sprinkler Co., LTDSS8464RC-RES4.9Pendent½White162°F3VikingVK696ATTIC4.2Upright½Brass200°F1Total = 26 Hydraulic Calculations for Project Name: THE CENTRE Location: LAQUINTA, CA92253, , Drawinq Name: DELTA 1 - PLAN 4 Design Remote Area Number: Remote Area Location: Occupancy Classification Density Area of Application: Coverage per Sprinkler: Type of sprinklers calculated No. of sprinklers calculated: No. of nozzles calculated: In -rack Demand: Hose Streams: Calculation Date: 1/6/2023 1- 18'x18' SPACING DINING Residential 0.050gpm/ft2 648.00ft2 (Actual 80.12ft2) 324.00ft2 Pendent 2 0 N/A gpm at Node: N/A 0.0 gpm at Node: 1 Type: Allowance at Source 5.00 at Node: 500 Type: Hose 5.00 at Node: 600 Type: Hose 5.00 at Node: 400 Type: Hose 5.00 at Node: 300 Type: Hose 5.00 at Node: 200 Type: Hose 5.00 at Node: 100 Type: Hose Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 64.06 @ 78.261 Type of System: 13D Volume of Dry/PreAction/Antifreeze/OtherAgent N/A for Node: 1 Date: 1/25/2022 Location: Southerly portion of La Quinta Dr. Source: COACHELLA VALLEY WATER DISTRICT Name of Contractor: ON GUARD FIRE PROTECTION Address: 6438 ARVILLE STREET, LAS VEGAS, NV 89118 Phone Number: 702-966-8021 Name of designer: ZULEMA ROSALES Authority Having Jurisdiction: City of La Quinta Notes: Automatic peaking results Left: 78.261 Right: 78.261 (Safety Margin = 2.218) L© M.E.P.CAD, Inc. �JJJAutoSPRINK 2020 06.3.23.0 1- 18'x18' SPACI 1/6/2023 3:28:50PM Page 1 i Hydraulic Summary Job Number: 22-20-20 Report Description: Residential (1- 18'x18' SPACING) Job Number Design Engineer 22-20-20 ZULEMA ROSALES Job Name: THE CENTRE State CertifcationlLicense Number Address I LA QUINTA, CA 92253 AHJ City of La Quinta Address 2 Job SitalBmldmg The Centre Address 3 Drewing Name DELTA 1 - PLAN 4 System Remote Area(s) Most Demanding Sprinkler Data Occupancy Job SuRx 4.9 K-Factor 16.97 at 12.000 Residential Hose Allowance At Soume Density Area of Application 0.00 0.050gpm/ft2 648.00ft2 (Actual 80.12ft2) Additional Hose Supplies Number Of Sprinklers Calculated Number Of Nomles Calculated Coyerege Per Sprinkler Node Flow(gpm) 2 0 324.00ft2 Hose At Node 500 5.00 Au.PeakResults :Pressure For Remote Area(s)AdjacentToMost Remote Ares Hose At Node 600 5.00 Left: 78.261 Right: 78.261 Hose At Node 400 5.00 Hose At Node 300 5.00 Hose At Node 200 5.00 Hose At Node 100 5.00 Total Hose Streams 30.00 System Flow Demand Total Water Required (Including Hose Allowance) 64.06 64.06 Maximum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Ground 18.21 between nodes 150 and 152 Maximum Velocity Under Ground 4.29 between nodes 3 and 4 Volume capacity of Wet Pipes Volume capacity of Dry Pipes 74.38gal Supplies Hose Flow Static Residual Flow Available Total Demand Required Safety Margin Node Name m(psi) (psi)°C m(psi) @ m(psi) (psi) 1 Water Supply 80.550 72.000 850.00 80.478 64.06 78.261 2.218 Contractor Contractor Number 950378 Contact Name BOBBY TAVAKOLI Comactrtle OWNER Name of Contractor. ON GUARD FIRE PROTECTION Phone 702-966-8021 Extension Add... 6438 ARVILLE STREET FAX 702-987-1174 Address 2 LAS VEGAS, NV 89118 E-mail BOBBY@ONGUARDFP.COM Address 3 Web-Slta k, @ M.E.P.CAD, Inc. l�jj AutoSPRINK 2020 06.3.23.0 1/6/2023 3:29:18PM Page 1 Hydraulic Graph Job Name: THE CENTRE N 1.85 Remote Area Number: 1- 18'x18' SPACING Date: 1/6/2023 100 Water Supply Summary Sheet so Node: 1 Available Supply Static Pressure 80.550 80 64.06 @ 80.478 850.00 @ 72.000 70 60 .N a 50 System demand curve IL 40 30 20 10 0 0200 400 600 800 1000 1200 1400 1600 1800 2000 Flow - gpm &@ M.E.P.CAD, Inc. �jjj AutoSPRINK 2020 v16.3.23.0 1/6/2023 3:28:54PM Paqe 2 �(P Summary Of Outflowing Devices C t % Job Number: 22-20-20 Report Description: Residential (1- 18'x18' SPACING) Device Actual Flow pm Minimum Flow pm K-Factor K(psi) Pressure Hose 100 5.00 5.00 0 51.645 y Sprinkler 101 16.97 16.97 4.9 12.000 Sprinkler 102 17.08 16.97 4.9 12.154 Hose 200 5.00 5.00 0 51.365 Hose 300 5.00 5.00 0 51.127 Hose 400 5.00 5.00 0 50.928 Hose 500 5.00 5.00 0 44.845 Hose 600 5.00 5.00 0 50.766 r* Most Demanding Sprinkler Data L, © M.E.P.CAD, Inc. 111 AutoSPRINK 2020 06.3.23.0 1/6/2023 3:28:56PM Page 3 Job Name: THE CENTRE Remote Area Number: 1- 18'x18' SPACING Date: 1 /6/2023 Supply Analysis Node Name Static (psi) Residual Flow (psi) co (gpm) Available Total Demand (psi) @ (gpm) Required Pressure (psi) 1 Water Supply 80.550 72.000 850.00 80.478 64.06 78.261 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 -3'-6 Supply 78.261 64.06 100 -4' Hose 51.645 5.00 Hos 101 19, Sprinkler 12.000 16.97 102 19, Sprinkler 12.154 17.08 200 -4' Hose 51.365 5.00 Hos 300 -4' Hose 51.127 5.00 Hos 400 -4' Hose 50.928 5.00 Hos 500 ill 44.845 5.00 600 -4' Hose 50.766 5.00 Hos 2 -4' 62.431 3 -4' 51.974 4 -4' 51.648 5 -4' 51.369 6 -4' 51.131 7 -4' 50.932 8 -4' 50.770 9 -4' 50.639 10 -4' 50.093 11 11" Supply 44.265 LM © M.E.P.CAD, Inc. AN AutoSPRINK 2020 06.3.23. 1/6/2023 3:29:OOPM Paqe 4 Job Name: THE CENTRE Remote Area Number: 1- 18'x18' SPACING Date: 1 /6/2023 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 150 9'-6 33.473 152 9'-6 28.577 250 19'-6 16.951 252 19'-6 13.469 256 19'-6 13.486 258 19'-6 16.100 &@ M.E.P.CAD, Inc. AN AutoSPRINK 2020 06.3.23. 1/6/2023 3:29:OOPM Paqe 5 Job Name: THE CENTRE Remote Area Number: 1- 18'x18' SPACING Date: 1 /6/2023 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices . Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 101 19, 4.9 16.97 % (See Notes) 2'-11 150 12.000 ••••• Route 1••••• Sprinkler, E(4'), Tr(1'), T(T) 8' 0.154637 -0.217 252 19'-6 16.97 0.8740 10'-11 1.685 252 19'-6 % (See Notes) 16'-6 150 13.469 2Tr(1'), E(4'), T(T) 9' 0.136529 250 19'-6 15.87 0.8740 25'-6 3.483 250 19' 6 3.84 %(See Notes) 20'-9 150 16.951 Flow (q) from Route 9 2E(4'), 2T(3'), Tr(1') 15' 0.203818 4.335 152 9'-6 19.71 0.8740 35'-9 7.290 152 9'-6 14.35 % (See Notes) 4'-9 150 28.577 Flow (q) from Route 2 E(4') 4' 0.560768 150 9'-6 34.06 0.8740 8 9 4.896 150 9'-6 1 (See Notes) 10'-10 150 33.473 4E(5'), f(-0.000), 2Tr(1'), sCV(5 ), cplg(1'), BASE OF RISER 28' 0.182154 3.722 11 11" 34.06 1.1010 38'-10 7.070 11 11 " 1 101, 150 44.265 0.258059 0.363 500 ill 34.06 1.0250 10" 0.216 500 1" 5.00 1 (See Notes) 5' 1 150 44.845 2E(2'-8) 5-5 0.332491 1.767 10 -4' 39.06 1.0250 10'-6 3.482 10 -4' 2 50' 150 50.093 0.010922 9 -4' 39.06 2.0670 50' 0.546 9 4, 2 /z 28'-4 150 50.639 0.004597 8 -4' 39.06 2.4690 28'-4 0.130 8 -4' 5.00 2'/2 28'-4 150 50.770 Flow (q) from Route 3 0.005744 7 4 44.06 2.4690 28'-4 0.163 7 -4' 5.00 2% 28'-4 150 50.932 Flow (q) from Route 4 0.007008 6 4 49.06 2.4690 28'-4 0.199 & © M.E.P.CAD, Inc. �jjj AutoSPRINK 2020 06.3.23.0 1- 18'x18' SPACING 1/6/2023 3:29:02PM Page 6 Job Name: THE CENTRE Remote Area Number: 1- 18'x18' SPACING Date: 1 /6/2023 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. F oot) (Foot) ) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 6 4' 5.00 2'/z 28' 4 150 51.131 Flow (q) from Route 5 0.008386 5 -4' 54.06 2.4690 28'-4 0.238 5 -4' 5.00 2'/2 28'-4 150 51.369 Flow (q) from Route 6 0.009877 4 -4' 59.06 2.4690 28'-4 0.280 4 -4' 5.00 2'/2 28'-4 150 51.648 Flow (q) from Route 7 0.011480 3 -4' 64.06 2.4690 28'-4 0.325 3 4' 2 (See Notes) 1' 150 51.974 WMV(-2.000) 0.035425 2 -4' 64.06 1.9590 1 10.457 2 -4' 2 (See Notes) 25' 150 62.431 AngV(-3.300), T(T), BaIV(-0.08 0), S 7' 0.035425 -0.217 1 -T-6 64.06 1.9590 32 16.046 0.00 78.261 Hose Allowance At Source Total(Pt) Route 1 1 64.06 102 19, 4.9 17.08 '/, (See Notes) 2'-11 150 12.154 ..... Route 2 Sprinkler, E(4'), T(3') 7' 0.156470 -0.217 256 19'-6 17.08 0.8740 9 11 1.549 256 19'-6 1.11 '/, (See Notes) 10'-11 150 13.486 Flow (q) from Route 8 Tr(1'), T(3') 4' 0.175710 258 19'-6 18.19 0.8740 14'-11 2.614 258 19'-6 3/, (See Notes) 49'-10 150 16.100 3E(4'), T(3'), 7Tr(1') 22' 0.113341 4.335 152 9'-6 14.35 0.8740 71'-10 8.141 28.577 Total(Pt) Route 2 600 4' 5.00 2 (See Notes) 1' 150 50.766 ..... Route 3 Hose PO(11'-8) 11'-8 0.000316 8 -4' 5.00 1.9590 12' 8 0.004 50.770 Total(Pt) Route 3 & © M.E.P.CAD, Inc. �jjj AutoSPRINK 2020 06.3.23.0 1- 18'x18' SPACING 1/6/2023 3:29:02PM Page 7 Job Name: THE CENTRE Remote Area Number: 1- 18'x18' SPACING Date: 1 /6/2023 Pipe Information Elev 1 Flow added Fittings & Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) pf Friction Elev(Pe) (q) . Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow Loss Per Unit when applicable, are added Total Friction(Pf) Node 2 (Foot) (Q) Actual ID Length (Foot) (psi) directly to (Pf) and shown as (Foot) 400 -4' 5.00 2 (See 1' 150 50.928 ••••• Route 4••••• Hose 11'-8 Notes) 7 -4' 5.00 1.9590 0.000316 PO(11'-8) 12' 8 0.004 50.932 Total(Pt) Route 4 300 -4' 5.00 2 (See 1' 150 51.127 ..... Route 5 Hose 11'-8 Notes) 6 -4' 5.00 1.9590 0.000316 PO(11'-8) 12' 8 0.004 51.131 Total(Pt) Route 5 200 -4' 5.00 2 (See 1' 150 51.365 ••••• Route 6••••• Hose 11'-8 Notes) 5 -4' 5.00 1.9590 0.000316 PO(11'-8) 12' 8 0.004 51.369 Total(Pt) Route 6 100 -4' 5.00 2 (See 1 150 51.645 ..... Route 7 Hose 11'-8 Notes) 4 -4' 5.00 1.9590 0.000316 PO(11'-8) 12' 8 0.004 51.648 Total(Pt) Route 7 252 19'-6 15.87 '/, (See 15-7 150 13.469 ..... Route 8 Flow (q) from Route 1 2' Notes) 256 19'-6 1.11 0.8740 0.000987 2Tr(1') 17' 7 0.017 13.486 Total(Pt) Route 8 258 19'-6 % (See 62'-2 150 16.100 ..... Route 9 T(T) 24' Notes) 250 19'-6 3.84 0.8740 0.009879 6T(3'), 3Tr(1') 86-2 0.851 16.951 Total(Pt) Route 9 & © M.E.P.CAD, Inc. �jjj AutoSPRINK 2020 06.3.23.0 1- 18'x18' SPACING 1/6/2023 3:29:02PM Page 8 Job Name: THE CENTRE Remote Area Number: 1- 18'x18' SPACING Equivalent Pipe Lenoths of Valves and Fittinos (C=120 only) IC Value Multiplier Date: 1 /6/2023 Actual Inside Diameter 4.87 I Value Of C 100 130 140 150 = Factor Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Back -flow Preventer BV Butterfly Valve C Cross Flow Turn 90' cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90' Elbow EE 45' Elbow Eel 11'/4' Elbow Ee2 22'/2' Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 900 FireLock(TM) Elbow fEE 450 FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90' Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap & © M.E.P.CAD, Inc. �jjj AutoSPRINK 2020 06.3.23.0 1- 18'xl8' SPACING 1/6/2023 3:29:02PM Page 9 Hydraulic Calculations for Project Name: THE CENTRE Location: LAQUINTA, CA92253, , Drawinq Name: DELTA 1 - PLAN 4 Design Remote Area Number: Remote Area Location: Occupancy Classification Density Area of Application: Coverage per Sprinkler: Type of sprinklers calculated No. of sprinklers calculated: No. of nozzles calculated: In -rack Demand: Hose Streams: Calculation Date: 1/6/2023 2- 20'x20' SPACING DINING Residential 0.050gpm/ft2 400.00ft2 (Actual 125.55ft2) 400.00ft2 Pendent 1 0 N/A gpm at Node: N/A 0.0 gpm at Node: 1 Type: Allowance at Source 5.00 at Node: 500 Type: Hose 5.00 at Node: 600 Type: Hose 5.00 at Node: 400 Type: Hose 5.00 at Node: 300 Type: Hose 5.00 at Node: 200 Type: Hose 5.00 at Node: 100 Type: Hose Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 51.02 @ 60.166 Type of System: 13D Volume of Dry/PreAction/Antifreeze/OtherAgent N/A for Node: 1 Date: 1/25/2022 Location: Southerly portion of La Quinta Dr. Source: COACHELLA VALLEY WATER DISTRICT Name of Contractor: ON GUARD FIRE PROTECTION Address: 6438 ARVILLE STREET, LAS VEGAS, NV 89118 Phone Number: 702-966-8021 Name of designer: ZULEMA ROSALES Authority Having Jurisdiction: City of La Quinta Notes: Automatic peaking results Left: N/A Right: N/A (Safety Margin = 20.337) L© M.E.P.CAD, Inc. �JJJAutoSPRINK 2020 06.3.23.0 2- 20'x20' SPACI 1/6/2023 3:29:55PM Page 1 i Hydraulic Summary Job Number: 22-20-20 Report Description: Residential (2- 20'x20' SPACING) Job Number Design Engineer 22-20-20 ZULEMA ROSALES Job Name: THE CENTRE State CertifcationlLicense Number Address I LA QUINTA, CA 92253 AHJ City of La Quinta Address 2 Job SilelBmldmg The Centre Address 3 Drewing Name DELTA 1 - PLAN 4 System 111111Remote Area(s) Most Demanding Sprinkler Data Occupancy Job SuRx 4.9 K-Factor 21.02 at 18.400 Residential Hose Allowance At Soume Density Area of Application 0.00 0.050gpm/ft2 400.00ft2 (Actual 125.55ftz) Additional Hose Supplies Number Of Sprinklers Calculated Number Of Nomles Calculated Coyerege Per Sprinkler Node Flow(opm) 1 0 400.00ft2 Hose At Node 500 5.00 AutoPeakResults :Pressure For Remote Area(s)AdjacentToMost Remote Area Hose At Node 600 5.00 Hose At Node 400 5.00 Hose At Node 300 5.00 Hose At Node 200 5.00 Hose At Node 100 5.00 Total Hose Streams 30.00 System Flow Demand Total Water Required (Including Hose Allowance) 51.02 51.02 Maximum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Ground 11.24 between nodes 254 and 201 Maximum Velocity Under Ground 3.42 between nodes 3 and 4 Volume capacity of Wet Pipes Volume capacity of Dry Pipes 74.38gal Supplies Hose Flow Static Residual Flow Available Total Demand Required Safety Margin Node Name m(psi) (psi)°C m(psi)@ m(psi) (psi) 1 Water Supply 80.550 72.000 850.00 80.503 51.02 60.166 20.337 Contractor Contractor Number 950378 Contact Name BOBBY TAVAKOLI Conact Title OWNER Name of Contractor. ON GUARD FIRE PROTECTION Phone 702-966-8021 Extension Add... 6438 ARVILLE STREET FAX 702-987-1174 Address 2 LAS VEGAS, NV 89118 E-mail BOBBY@ONGUARDFP.COM Address 3 Web-Slte k, @ M.E.P.CAD, Inc. l�jj AutoSPRINK 2020 06.3.23.0 1/6/2023 3:30:18PM Page 1 Job Name: THE CENTRE Remote Area Number: 2- 20'x20' SPACING 100 90 80 70 60 .N a 50 a� IL` 40 30 20 10 Hydraulic Graph N 1.85 Date: 1 /6/2023 Water Supply Summary Sheet Node: 1 Available Supply Static Pressure 80.550 51.02 @ 80.503 850.00 @ 72.000 51.02 60.166 System demand curve DO 1000 1200 1400 Flow - gpm 1600 1800 0011111 &@ M.E.P.CAD, Inc. �jjj AutoSPRINK 2020 v16.3.23.0 1/6/2023 3:29:57PM Paqe 2 ikummary Of Outflowing Devices Job Number: 22-20-20 Report Description: Residential (2- 20'x20' SPACING) Device Actual Flow pm Minimum Flow pm K-Factor K(psi) Pressure Hose 100 5.00 5.00 0 42.974 Hose 200 5.00 5.00 0 42.798 ♦ Sprinkler 201 21.02 21.02 4.9 18.400 Hose 300 5.00 5.00 0 42.655 Hose 400 5.00 5.00 0 42.543 Hose 500 5.00 5.00 0 38.734 Hose 600 5.00 5.00 0 42.458 ♦ Most Demanding Sprinkler Data L, © M.E.P.CAD, Inc. 111 AutoSPRINK 2020 06.3.23.0 1/6/2023 3:29:58PM Page 3 Job Name: THE CENTRE Remote Area Number: 2- 20'x20' SPACING Date: 1 /6/2023 Supply Analysis Node Name Static (psi) Residual Flow (psi) co (gpm) Available Total Demand (psi) @ (gpm) Required Pressure (psi) 1 Water Supply 80.550 72.000 850.00 80.503 51.02 60.166 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 -3'-6 Supply 60.166 51.02 100 -4' Hose 42.974 5.00 Hos 200 -4' Hose 42.798 5.00 Hos 201 19, Sprinkler 18.400 21.02 300 -4' Hose 42.655 5.00 Hos 400 -4' Hose 42.543 5.00 Hos 500 1" 38.734 5.00 600 -4' Hose 42.458 5.00 Hos 2 -4' 49.963 3 -4' 43.192 4 -4' 42.978 5 -4' 42.802 6 -4' 42.659 7 -4' 42.547 8 -4' 42.462 9 -4' 42.401 10 -4' 42.143 11 11" Supply 38.282 150 9'-6 31.665 LM © M.E.P.CAD, Inc. AN AutoSPRINK 2020 06.3.23. 1/6/2023 3:30:02PM Paqe 4 Job Name: THE CENTRE Remote Area Number: 2- 20'x20' SPACING Date: 1 /6/2023 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 152 9'-6 29.660 250 19'-6 22.368 254 19'-6 20.396 258 19'-6 21.946 LM © M.E.P.CAD, Inc. AN AutoSPRINK 2020 06.3.23. 1/6/2023 3:30:02PM Page 5 Job Name: THE CENTRE Remote Area Number: 2- 20'x20' SPACING Date: 1 /6/2023 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices . Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 201 19, 4.9 21.02 % (See Notes) 2'-8 150 18.400 ..... Route 1 Sprinkler, E(4'), T(T) 7' 0.229630 -0.217 254 19'-6 21.02 0.8740 9'-8 2.212 254 19'-6 % (See Notes) 2T-6 150 20.396 3Tr(1'), E(4'), T(T) 10, 0.052569 250 19'-6 9.47 0.8740 37'-6 1.973 250 19' 6 2.63 %(See Notes) 20'-9 150 22.368 Flow (q) from Route 8 2E(4'), 2T(3'), Tr(1') 15' 0.082657 4.335 152 9'-6 12.10 0.8740 35'-9 2.956 152 9'-6 8.92 % (See Notes) 4'-9 150 29.660 Flow (q) from Route 7 E(4') 4' 0.229630 150 9'-6 21.02 0.8740 8 9 2.005 150 9'-6 1 (1See Notes) 10'-10 150 31.665 4E(5'), f(-0.000), 2Tr(1'), sCV(5 '), cplg(1'), BASE OF RISER 28' 0.074591 3.722 11 11" 21.02 1.1010 38'-10 2.895 11 11 " 1 101, 150 38.282 0.105673 0.363 500 ill 21.02 1.0250 10" 0.089 500 1" 5.00 1 (See Notes) 5' 1 150 38.734 2E(2'-8) 5-5 0.156827 1.767 10 -4' 26.02 1.0250 10'-6 1642 10 -4' 2 50' 150 42.143 0.005152 9 -4' 26.02 2.0670 50' 0.258 9 4, 2 /z 28'-4 150 42.401 0.002168 8 -4' 26.02 2.4690 28'-4 0.061 8 -4' 5.00 2% 28'-4 150 42.462 Flow (q) from Route 2 0.003001 7 4 31.02 2.4690 28'-4 0.085 7 -4' 5.00 2% 28'-4 150 42.547 Flow (q) from Route 3 0.003957 6 4 36.02 2.4690 28'-4 0.112 & © M.E.P.CAD, Inc. �jjj AutoSPRINK 2020 06.3.23.0 2- 20'x20' SPACING 1/6/2023 3:30:04PM Page 6 Job Name: THE CENTRE Remote Area Number: 2- 20'x20' SPACING Date: 1 /6/2023 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices . Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 6 4' 5.00 2'/z 28' 4 150 42.659 Flow (q) from Route 4 0.005033 5 -4' 41.02 2.4690 28'-4 0.143 5 -4' 5.00 2'/2 28'-4 150 42.802 Flow (q) from Route 5 0.006226 4 -4' 46.02 2.4690 28'-4 0.176 4 -4' 5.00 2'/2 28'-4 150 42.978 Flow (q) from Route 6 0.007535 3 -4' 51.02 2.4690 28'-4 0.213 3 4' 2 (See Notes) 1' 150 43.192 WMV(-10.389) 0.023252 2 -4' 51.02 1.9590 1 6.771 2 -4' 2 (See Notes) 25' 150 49.963 AngV(-14.413), T(T), BaIV(-0.4 53), S 7' 0.023252 -0.217 1 -T-6 51.02 1.9590 32 10.420 0.00 60.166 Hose Allowance At Source Total(Pt) Route 1 1 51.02 600 -4' 5.00 2 (See Notes) 1' 150 42.458 ••••• Route 2••••• Hose PO(11'-8) 11'-8 0.000316 8 -4' 5.00 1.9590 12' 8 0.004 42.462 Total(Pt) Route 2 400 -4' 5.00 2 (See Notes) 1 150 42.543 ..... Route 3 Hose PO(11'-8) 11'-8 0.000316 7 -4' 5.00 1.9590 12' 8 0.004 42.547 Total(Pt) Route 3 300 -4' 5.00 2 (See Notes) 1' 150 42.655 ••••• Route 4••••• Hose PO(11'-8) 11'-8 0.000316 6 -4' 5.00 1.9590 12' 8 0.004 42.659 Total(Pt) Route 4 200 -4' 5.00 2 (See Notes) 1' 150 42.798 ••••• Route 5••••• Hose PO(11'-8) 11'-8 0.000316 5 -4' 5.00 1.9590 12 8 0.004 & © M.E.P.CAD, Inc. �jjj AutoSPRINK 2020 06.3.23.0 2- 20'x20' SPACING 1/6/2023 3:30:04PM Page 7 Job Name: THE CENTRE Remote Area Number: 2- 20'x20' SPACING Date: 1 /6/2023 Pipe Information Elev 1 Flow added Fittings & Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) pf Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow Loss Per Unit when applicable, are added Total Friction(Pf) Node 2 (Foot) (Q) Actual ID F oot) (Foot) ) (psi) directly to (Pf) and shown as (Foot) 42.802 I Total(Pt) Route 5 100 -4' 5.00 2 (See 1' 150 42.974 • • • • • Route 6 Hose 11'-8 Notes) 4 -4' 5.00 1.9590 0.000316 PO(11'-8) 12' 8 0.004 42.978 Total(Pt) Route 6 258 19'-6 3/4 (See 49'-10 150 21.946 ..... Route 7 22' 4.335 Notes) 152 9'-6 8.92 0.8740 0.047030 3E(4'), T(3'), 7Tr(1') 71'-10 3.378 29.660 Total(Pt) Route 7 254 19'-6 9.47 % (See 15'-6 150 20.396 ..... Route 8 Flow (q) from Route 1 5' Notes) 258 19'-6 11.55 0.8740 0.075800 2Tr(1'), T(T) 20'-6 1.551 258 19' 6 3/4 (See 62'-2 150 21.946 T(T) 24' Notes) 250 19'-6 2.63 0.8740 0.004895 6T(3'), 3Tr(1') 86-2 0.422 22.368 Total(Pt) Route 8 & © M.E.P.CAD, Inc. �jjj AutoSPRINK 2020 06.3.23.0 2- 20'x20' SPACING 1/6/2023 3:30:04PM Page 8 Job Name: THE CENTRE Remote Area Number: 2- 20'x20' SPACING Equivalent Pipe Lenoths of Valves and Fittinos (C=120 only) IC Value Multiplier Date: 1 /6/2023 Actual Inside Diameter 4.87 I Value Of C 100 130 140 150 = Factor Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Back -flow Preventer BV Butterfly Valve C Cross Flow Turn 90' cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90' Elbow EE 45' Elbow Eel 11'/4' Elbow Ee2 22'/2' Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 900 FireLock(TM) Elbow fEE 450 FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90' Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap & © M.E.P.CAD, Inc. �jjj AutoSPRINK 2020 06.3.23.0 2- 20'x20' SPACING 1/6/2023 3:30:04PM Page 9 Z Domestic Water System Flow Analysis Coachella Valley Water District 75515 Hovley Lane East Palm Desert, CA 92211 Domestic Water System Flow Analysis (Hydraulic Model) GEO 05-07-29-3 PZ 22-13103 Requested By: Vertical Integrity Date: 1/25/2022 Address: 47260 Adams Street APN: 600-340-049, 050, 051 La Quinta, 92253 Req. Fire Flow: gpm at 20psi for hours. Contact Name: David Kinnett Project Name: The Centre at La Quinta Phone: 949-279-2418 Email: dk@verticalintegrity.net Cell: System DomestFlow is Hydrant locate at the southerly portion of La Quinta Dr Analysater Flow Analysis Location: Model Information Flow Analysis Description DomesticCVWD • • Requested • Test 1 Test 2 Test 3 Test 4 Flow Domestic Elevation (Ft): 66 None system flow available without exceeding Steady State, Dynamic (psi): 89.5 Residual Pressure (psi): 80 Fire Flow Tested (gpm): 2,650 N/A CVWD's Combined Total: N/A criteria. Tested Model Junction: J22719 Duration: 2 hours Demand Conditions: Peak Day Demand (PDD) Reservoir No./Level (s): Reservoir 6630/27.5' Pumps Operating No's: Pumps On Pressure Zone and HGL: Lower La Quinta (235') Model: CVWD DOMESTICWATER_2020UPDATE_092221 Comments: The domestic water system is capable of providing 2,650 gpm for 2 hours that satisfies CVWD's minimum pressure, velocity, and/or head loss criteria. This flow can be achieved by using multiple fire hydrants. This simulated system flow analysis may not include all facilities that may be required for this development/project. Please check with Development Services for further information on all required acilities. The theoretical flow to drop the residual pressure to 20 psi is greater than 5,000 gpm. Please note he theoretical flow exceeds CVWD's design criteria on the domestic water network. These results are based on hydraulic modelling and not a guarantee that CVWD's domestic water system will have the capacity to supply water to the project at the flows or pressures indicated. It is important to note that the capacity of the on -site fire system, meters, service lines, backflow assemblies and other appurtenances were not considered in this analysis, which may alter actual flows or pressures. Due to continuous changes in the system, CVWD only considers this system flow analysis valid for six months from date of modelling/analysis. These system flow analysis comments are for plan check purposes only. The ultimate design responsibility resides with the Engineer -of -Record for this Project. Should you have any questions or need additional information, please contact me at (760) 398-2661, ext. 2397. i Completed By: Date: ^1MZ Page 1 of 1 ENG DS-016 COZ41 ��O- (8/31/15) LL) Ld n I I NISSgN )9513. 117— ILL' I I q.RRI BIIRR q r\ R9i23 I B"O.1.P.-99 R9-223 AUTO e.p 30=R26 �02 R3=32. 3p`RO6 e°O�3 CENT �z Eq ,e•D.r.P T ORI�f _ ]9e r � c•�os O 0 0 0 � 0 o e C 3 o e o w It O° o e O o e Q 0 0 o e e o o e o 0 e O 0 e o o e d d a ov e.os o. IRR I9 5 W R•�350 >]>.9 101t IDS p ]00032 GB -6 IR4 10�2 Fpi' a SIC"S MP, OS R- 4 049 t9-25S I g q.O5g3R 12"DIP 6't 3 �03 � 9-265 Z R4 ] GOODYE O trR AR m 41Rp08 C I 6'�DS sFNDV"S P e.00see2 � O i J9-275 12929.1 N O ,hydrants to be nRpCry CE c= O U O r 12929.1 12-D 1 P -03 CVSI I z WESITE J l I fl WAL - MART 30BI00 �9-293 1®E kill�IifaQ Page : 1 of 8 SENJU SPRINKLER CO., LTD. Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 4.9, SIN: SS8464 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. They are decorative and fast responding. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push -on and/or thread -on, thread -off design of the concealed cover plate assembly allows for easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for residential occupancies and is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar'/Z) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents to escape or evacuate in case of a fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. "Lead Free" is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA's Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. WARNINGS The Model RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or their representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Document No. U085166 Date : Jul/08/2019 TECHNICAL DATA Approvals: ,UL„, Listed, NSF-61-G Sprinkler Identification Number (SIN): SS8464 Maximum Working Pressure: 175psi (12.1bar) Discharge Coefficient (Nominal K-Factor): K=4.9 GPM/psi112 (70.6 LPM/bart12) Temperature Rating: 162°F (72°C) Sprinkler with 140°F (60°C) Cover Plate 175°F (79°C) Sprinkler with 140°F (60°C) Cover Plate 175°F (79°C) Sprinkler with 162°F (72°C) Cover Plate 205oF (96°C) Sprinkler with 162°F (72°C) Cover Plate Color Code (Sprinkler) 162°F (72°C): Uncolored 175°F (79°C): White 205°F (96°C): White Color Code (Cover Plate) 140°F (60°C): No Mark 162°F (72°C): White -Colored Mark Vertical Adjustment: 112 inch (12.8 mm) Cover Plate Finishes: Standard Finishes - White, Ivory, Beige, Brown, Black, Nickel, Wood Grain Custom Finishes - Custom color and custom pattern cover plates are available on special order. Contact a Senju Sprinkler representative with any custom orders. Please see chart on Page 8 for more detail. Physical Characteristics: Ref. Figures 1 and 1-1 OPERATION Page : 2 of 8 2-1 / T 6- (0 52mm) Marking lam Lot No. Year of Manufacture SIN : SS8464 K-factor: K4.9 Temperature Rating' 162'F/72C or 175F/79`C UL Mark or 205F/96`C 7 CnnUol No.: 6P37 NSF Mark ! NSF-61-G RES SPKR 1) Body (Copper Alloy) (2) Deflector(Phosphorus Bronze) ® Gasket (PTFE) 68mm) ® Fuvlble Metal (Solder) 83mm) (9) Heat collector (Capper) 68mm 4V Cover Plate Assembly FIGURE 1. Model RC-RES K=4.9 Marking (Deflector) SIN : SS8464 K-factor - K4.9 Color Code Temperature Rating 162'F/72'C ,o or I75F/79'C UL Mark or 205F/96'C 0 0 -I o d CM 0 0 .e COVER PLATE SPRINKLER (Top view) (Bottom view) FIGURE 1-1. Marking (Color Code) In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is reached, internal components of the sprinkler fall apart. This leads to the water flow to be distributed on the affected fire area. (Ref. Figure 2) I •tee - -- - — ��- � OperationNormal Condition Cover Plate Operation Sprinkler FIGURE 2. OPERATION PROCESS (The Agure is for illustrative Purposes only) Document No. U085166 Date : Jul/08/2019 Page : 3 of 8 DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not covered by the following instructions, should be submitted to your contracted company. Include sketches and technical details, as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority having jurisdiction. The Model RC-RES must not be used in applications where the airpressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radially outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R) must be kept as few as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided for the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13, 13D and 13R for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D, 13R or 13 for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to the exposure of a heat source other than an actual fire. Available Sprinkler Temperature Ratings Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating Maximum Ambient Ceiling Temperature Temperature Rating of the Cover Plate Assembly Ordinary 162°F (72°C) 100°F (38°C) 140°F (60°C) Intermediate 175°F (79°C) 150°F (66°C) 140°F (60°C)'� Intermediate 175°F (79°C) 150°F (66°C) 162°F (72°C) Intermediate 205°F (96°C) 150°F (66°C) 162°F (72°C) 1) Maximum ambient temperature for the Cover Plate Assembly is 100°F (38°C). Precautionary Warnings for Corrosive Environments Model RC-RES sprinklers should not be installed where they may be subjected to a corrosive environment including the following: (1) Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non -Fire conditions or Not Operating when exposed to an actual fire. (2) Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) — Solder Joint) All residual flux must be removed from the interior and exterior of the copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and/or leakage in the sprinkler system. Document No. U085166 Date : Jul/08/2019 Page : 4 of 8 Hydraulic Design Criteria The minimum required sprinkler flow rates for systems designed to NFPA 13D or 13R are given in TABLE A as a function of temperature rating and the maximum allowable coverage area. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of "design sprinklers" as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in TABLE A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. A minimum discharge of 0.1GPM/sq.ft. [4.07LPM/sq.m] over the "design area" comprised of the four most hydraulically demanding sprinklers for the actual coverage area being protected by the four sprinklers. TABLE A. NFPA 13D & 13R WET PIPE HYDRAULIC DESIGN CRITERIA for Model SS8464 For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R or 13 as applicable. Ordinary Intermediate Intermediate Maximum Maximum Temperature Rating Temperature Rating Temperature Rating Minimum Covera e Spacing 162°F (72°C) 175°F (79°C) 205°F (96°C) Deflector Installation Spacing Areaia� to Flow Pressure(b) Flow(b) Pressure Flow Pressure(b)Type Ft. X Ft. Ft. Ceiling Ft. (m Xm) (m) GPM PSI GPM PSI GPM PSI (m) (LPM) (bar) (LPM) (bar) (LPM) (bar) 12X12 12 13 7.0 13 7.0 13 7.0 Smooth (3.7X3.7) (3.7) (49.2) (0.48) (49.2) (0.48) (49.2) (0.48) Ceilings 3/8 to 7/8 14X14 14 13 7.0 13 7.0 13 7.0 Inches. (4.343) (4.3) (49.2) (0.48) (49.2) (0.48) (49.2) (0.48) Beamed Ceilings 16X16 16 13 7.0 13 7.0 per NFPA 8 (4.949) (4.9) (49.2) (0.48) (49.2) (0.48) 13D, 13R Concealed (2.4) or 13 Installed in 18X18 18 17 12.0 17 12.0 beam (5.5X5.5) (5.5) (64.4) (0.83) (64.4) (0.83) 3/8 to 7/8 inches below 20X20 20 21 18.4 21 18.4 bottom of (6.1 X6.1) (6.1) (79.5) (1.27) - - (79.5) (1.27) beam. (a) For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. Sprinkler Spacin_q Criteria The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. TABLE A) Document No. U085166 Date : Jul/08/2019 Page : 5 of 8 INSTALLATION The Model RC-RES must be installed in accordance with the following instructions: NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to the sprinklers that could cause improper operation or non -operation. The Protective Cap must remain on the sprinkler during installation. After the installation is completed, the Protective Cap must be removed to place the sprinkler in service. Use a torque of 7 to 14 ft•lbs (9.5 to 19.0 N•m) to achieve a 112 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. Use only NR-H model wrench socket for installation of RC-RES sprinklers. Use of any other wrench or socket is prohibited and may cause damage to the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Do not rotate the Cap Remover RC to the left with force when placing the two hook arms into place. The installed sprinkler may become loosened, which may cause water leakage. Installing Procedure Step 1 The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inches (50.8mm) as shown in Figure 3. Step 2 With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Socket NR-H or Ratchet (3/8" drive) & Socket NR-H Combination (Ref. Figure 4). The teeth of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3 If desired, the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with a 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the "Vertical Adjustment' indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Step 4 Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just has contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot contact the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6. Make a Space Here Do Not Ave. 1/4" ($.4mm) Over -Tighten Min. 1/8" 3-2m GrLNR-H r EVertical m A 'ustment i N �*9i� li et E Nw Mounting SurfaceatchetMounting 2-3/8"' (� B0rnm)SurfaceCeiling Hole Diameter FIGURE 3. INSTALLATION FIGURE 4. RATCHET & SOCKET Document No. U085166 Date : Jul/08/2019 Hook up Sprinkler Head Protective Cep T 1 i I Cap Remover RC I i I i f Pull down Step I Step 2 Step 3 FIGURE 5. PROTECTIVE CAP REMOVAL E E 00 R r.� Cover Pula Assembly 2-5/8" 68mm) or 3-114" (d 83mm) or 2-5.8"square (068mm) FIGURE 6. INSTALLATION (COVER PLATEASSEMBLY) ]NCORREC7 CORRECT1 INCORRECT FIGURE 7. INSTALLATION (CORRECT and INCORRECT) Page : 6 of 8 Document No. U085166 Date : Jul/08/2019 Page : 7 of 8 CARE AND MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-RES. NOTES Wet pipe sprinkler systems must be maintained at a minimum temperature of 40°F/4°C to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of a fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non -operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non -factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities, and all affected parties by this action, and must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and/or water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler system to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must be kept in a cool and dry place. Automatic sprinklers must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units because of dropping, hitting, over -tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area, and the same or lower flow ratings (as indicated under TABLEA "Hydraulic Design Criteria'). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verify that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing of its compliance with this document, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. Limited Warranty For details of warranty, refer to Sales Contract. Document No. U085166 Date : Jul/08/2019 Page : 8 of 8 ORDER PROCEDURE When placing an order, please contact a local distributor with the following information (Model Name, Temperature Rating and Finish). Sprinkler Model: RC-RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162°F (72°C) or 175°F (79°C) or 205°F (96°C)) Cover Plate Assembly 2-5/8 inch (0 68mm) or 3-1/4 inch (0 83mm) or 2-5/8 inch square (❑68mm), Order Separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. Standard Finishes Custom Finishes White Ivory Beige Brown Black Nickel Copper Wood Grain Custom Color Custom Pattern 2-5/8" Round, 140°F 0 0 - - - - - - 0 0 3-1/4" Round, 140°F 0 0 0 0 0 0 0 0 0 0 2-5/8" Square, 140°F 0 - - - - - - - 0 0 2-5/8" Round, 162°F 0 - - - - - - - 0 0 3-1/4" Round, 162°F 0 - - - - - - - 0 0 Tools for Installation of Model RC-RES Socket NR-H For use with a 3/8" drive ratchet (not included) Socket NR-H Plastic For use with a 1/2" drive ratchet (not included) • Cap Remover RC Document No. U085166 Date : Jul/08/2019 Page 1 of 7 ® ATTIC UPRIGHT SPECIFIC APPLICATION 4 I KiSPRINKLER VK696 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. 1. DESCRIPTION The Viking Attic Upright VK696 is a specific application concealed space sprinkler that provides superior fire protection in combustible and non-combustible sloped attic spaces when used in conjunction with Viking's model V-BB (Back to Back) and V-SD (Single Directional) specific application sprinklers. Installed in the upright position, with the deflector parallel to the roof, the Attic Upright used in combination with the model V-BB increases the allowable span from 60' to 80' (18,3 m to 24,4 m). Viking Attic Upright sprinklers can be installed with either steel or CPVC piping, and allow the use of CPVC to feed the protected space below the attic (CPVC allowed on wet pipe systems only). They are available in brass or with corrosion -resistant Electroless Nickel PTFE (ENT) coatings where salt water and other corrosive elements are a consideration. Viking Attic Upright sprinklers are cULus Listed with specific application guidelines for use as special sprinklers as defined by the National Fire Protection Association (NFPA), and are listed for specific pitch range 4:12 to 12:12. 2. LISTINGS AND APPROVALS O cULus Listed: Category VNIV C US Refer to the Approval Chart on page 3. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.2 U.S. (57 metric*) Attic Upright Sprinkler VK696 NOTE: As of May 2018 all logos have been re- moved from the wrench boss. WARNING: Cancer and Reproductive Harm- www.P65Warnings.ca.gov * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass -bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (57 mm) Covered by the following U.S. Patent No.: 8,083,002 owned by Tyco. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Ordering Information: (Also refer to the current Viking price list.) To order the Attic Sprinkler, add the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, ENT = JN Temperature Suffix: E = 200 °F (93.3 °C) Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrench: Standard Wrench: Part No. 21475M/B Sprinkler Cabinets: A. Six -head capacity: Part No. 01724A B. Twelve -head capacity: Part No. 01725A Form No. F_042815 18.10.11 Rev 18.2.P65 Replaces Form F_042815 Rev. 18.2 (Added P65 Warning.) Page 2 of 7 ® ATTIC UPRIGHT SPECIFIC APPLICATION 4 I KiSPRINKLER VK696 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. 4. INSTALLATION Refer to appropriate NFPA Installation Standards. NOTE: Precedence for allowing 4.2K sprinklers to be used on dry pipe systems utilizing corrosion -resistant or internally galva- nized steel pipe is based on paragraph 8.3.4.4 of NFPA 13 (2013 edition). 5. OPERATION During a fire condition, the heat sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern to extinguish or control the fire, and protect the piping in the interstitial space. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Attic Upright Specific Application Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Bulb Color Ceiling Temperature' Intermediate 200 °F (93.3 °C) 150 °F (65°C) Green Sprinkler Finishes: Brass, ENT Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 cULus Listed as corrosion resistant. Protective Sprinkler Cap Wrench Flat O[i<ai Figure 1: Standard Sprinkler Wrench �1-1/4" (32 mm) I 2-1 /4" (57 mm) 7/16" (12 mm) J 1/2" (15 mm) Nominal Pipe Engagement NPT (Dimensions are approximate) Form No. F_042815 18.10.11 Rev 18.2.P65 Page 3 of 7 ® ATTIC UPRIGHT SPECIFIC APPLICATION 4 I KiSPRINKLER VK696 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. APPROVAL CHARTTemperature KEY Attic Upright Specific Application Sprinkler VK696 ♦+ Finish A1X F Escutcheon (if applicable) For Combustible and Non -Combustible Sloped Attic Spaces Part Maximum Thread Size Nominal K-Factor Overall Length g Listings and Approvals' g PP Number' SIN Pressure NPT BSP U.S. metricz Inches mm cULue FM LPCB E 19538 VK696 175 psi 1/2" 15 mm 4.2 57 2-1/4 57 A1, A2 I -- -- Approved Temperature Rating Approved Finish A - 200 -F (93.3 -C) 1 - Brass, 2 - ENT' Also refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. s This table shows the listings and approvals available at the time of printing. Other approvals may be in process. ° Listed by Underwriters Laboratories Inc. for use in the United States and Canada. ' cULus Listed as corrosion resistant. DESIGN CRITERIA - UL (Also refer to Approval Chart 1) Allowable Roof Span, Flow, Pressure and Slope for Specific Application Sprinkler Protecting Attics Sprinkler Thread Size Nominal Allowable Roof Minimum Minimum Dry Pipe System K-Factor Span Flow Pressure Maximum Water Base Part SIN Pitch' Delivery Time Number NPT BSP U.S. metric Ft. (M) GPM LPM PSI BAR (in seconds) Minimum 7 psi (0,48 Bar) 4:12 to 60 seconds 19538 VK696 1/2" 15 mm 4.2 57 10 (3,1) x 12 (3,6) Minimum 0.10 gpm/ft' (4,1 mm/min.) Design Density 12:12 (All System Sizes) NOTE: Precedence for allowing 4.2K sprinklers to be used on dry pipe systems utilizing corrosion -resistant or internally galvanized steel pipe is based on paragraph 8.3.4.4 of NFPA 13 (2013 edition). ' Pitch and slope indicate the incline of a roof, expressed as a proportion of the vertical to the horizontal. 2The Attic Upright is measured along the slope maximum 10 ft. (3,1 m) perpendicular to slope by maximum 12 ft (3,6 m) parallel to slope. IMPORTANT. Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of N FPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_042815 18.10.11 Rev 18.2.P65 Page 4 of 7 ® ATTIC UPRIGHT KJ SPECIFIC APPLICATION SPRINKLER VK696 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. ADDITIONAL DESIGN CRITERIA - UL Chart 2 (Also refer to DESIGN CRITERA Chart 1) Allowable roof span, flow, pressure and slope for attic protection using Viking V-SD Sprinklers Design Criteria: Flow and Pressures refer to Design Chart 1. System Type: Wet systems and dry systems. Piping Types: Steel (wet and dry) CPVC (wet systems only). Occupancy Classification: Light hazard only. Viking Attic Upright Sprinkler Spacing Maximum Coverage Area: 120 ft2 (11,2 m2) Minimum Spacing: 7'-0" (2,1 m) from Attic Upright Sprinklers, V-BB Sprinklers, V-SD Sprinklers, and Standard Spray Sprinklers, when measured along the peak/ridge direction. 26'-0" (7,9 m) from Viking V-BB and V-SD Sprinklers when measured down the slope. Maximum Spacing: 10'-0" (3,1 m) when measured perpendicular to the slope. 12'-0" (3,7 m) when measured parallel to the slope. Additional Spacing Considerations: If there is more than one row of Attic Upright Sprinklers, they must be staggered as shown in Figure 3. Attic Upright Sprinklers can provide up to 10'-0" (3,1 m) coverage at the eave(s) beyond the maximum allowable roof spans for the V-BB and V-SD Sprinklers by installing a row of Attic Uprights. Refer to Figure 4 and 5 for installation criteria in these situations. Deflector Position: Deflector located 1"— 3" (26 - 77 mm) below the bottom of the top chord or bottom of solid wood rafter for all roof pitches as per the listing from 4:12 — 12:12, with a maximum top chord or solid wood rafter depth of 12" (305 mm). Use of UL Listed CPVC Blazemaster Piping (Wet Systems Only): Can be used to supply the sprinklers protecting the floor below the combustible concealed space when covered with 6" (153 mm) of non-combustible insulation over the horizontal or vertical piping, and extending 12" (305 mm) on both sides of the center line of the piping. If the piping is located in the joist, the width of the joist channel must be entirely covered to 6" above the top of the piping. The area above the piping must be protected with the Viking Model V-BB's, V-SD's, or the Attic Upright Sprinklers. Listed CPVC Blazemaster piping may also be used exposed to provide wet system, vertical or angled, sprigs to Attic Upright Sprinklers where: • The exposed portion of an angled sprig is a maximum length of 3'-0" (0,9 m), with the sprig being supported adjacent to the Attic Upright Sprinkler, and vertical restraint is provided on the horizontal pipe runs with CPVC hangers. • Maximum exposed length on a sprig of 10'-0" (3,1 m), with a maximum lateral distance for the Attic Upright Sprinkler of 12" (305 mm) off of the centerline of the sprig. Sprig must also be supported at the swing joint to the Attic Upright Sprinkler. • Minimum 6" (153 mm) deep of non-combustible insulation extending 12" (305 mm) on each side of the pipe centerline for the CPVC branchline feeding the Attic Upright Sprinklers. • If the CPVC branchline is installed inside the ceiling joist, the joist channel must be covered or filled with a minimum of 6" (153 mm) deep non-combustible insulation on top of the branchline feeding the Attic Upright Sprinkler sprigs. • Additional non-combustible insulation can be added to reduce the exposed length of the sprigs being used with the Attic Upright Sprinklers. • Installed with a minimum lateral distance of 18" (458 mm) from any device that produces and releases heat, i.e Attic furnace, Kitchen or Bathroom Exhaust fan, Flue Vents, Heat Lamps, and other such devices. Continues on next page. Form No. F_042815 18.10.11 Rev 18.2.P65 Page 5 of 7 ® ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 -N41KJ 0 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Continued from previous page. Insulation requirements are provided solely for Fire Protection purposes and not for freeze protection. Non-combustible insulation being used needs to be verified for chemical compatibility with the CPVC piping at www.lubrizol.com Obstruction Criteria: Refer to Figures 6 and 7. Refer to Sections 8.8.5.2.1.3 and 8.8.5.2.1.7 of NFPA 13, 2013 for requirements if installed on greater than 2-1/2" diameter piping. Hydraulic Requirements: Minimum Design pressure: 7 psi Minimum design density: 0.10 gpm/sq. ft. For individual areas requiring more than four Attic Upright Sprinklers, the maximum area of the attic protected by Attic Upright Sprinklers is 3,000 ft (279 m2) in any single area. In order to be considered a single area, the areas protected by the Attic Upright Sprinklers must be separated by a minimum of 15'-0" (4,6 m), having that separation being protected by V-BB or V-SD sprinklers. The design area shall include the most hydraulically demanding sprinklers, and in certain cases may require more than one set of calculations to verify the systems design. Refer to the Technical Data Sheets for the Model V-BB (Form No. F_042915) and V-SD (Form No. F_043015) Specific Application Attic Sprinklers for more information regarding hydraulic requirements of Attic Upright Sprinklers. V-BB (Back to Back) V-SD (Single Directional) Attic Upright Top Side Top Side Top Side Form No. F_042815 18.10.11 Rev 18.2.P65 Page 6 of 7 ® ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 -N41KJ 0 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. When the total number of Attic Upright Sprinklers at the hip is greater than 4: Wet Systems: Calculate the most demanding 5 model V-BB Sprinklers, add the most demanding 2 Attic Upright Sprinklers, then calculate the most demanding region up to 1500 ft2 (137 m2) that uses Attic Upright Sprinklers (example: Region 1 at right). Use the most demanding calculation. Dry Systems: Calculate the most demanding 7 model V-BB sprinklers, add the most demanding 2 Attic Upright Sprinklers, then calculate the most demanding region up to 1950 ft2, (181 m2) that uses Attic Upright Sprinklers (example: Region 1 at right). Use the most demanding calculation. Region 1: Region 2: Region 3: Attic Upright Sprinklers V-BB Sprinklers Attic Upright Sprinklers • • Spacing must a ' ' be staggered S ;; 1 for additional 1 i rows coo� `�- 1 1 ;fie � 15' (4,6 m) Minimum � Refer to Figures 4 and 5 below. For attics having a span of 60 - 80 ft. (18,3 - 24,4 m), only the 8.OK model V-BB sprinklers combined with Attic Upright Sprinklers can be used. For attics with a span of over 80' (24,4 m), Standard Spray Spinklers must be used. In an attic using single ridge construction, 8.OK model V-BB sprinklers must be used to protect the center portion. Attic Upright sprinklers should be used to cover up to 10 feet (3,1 m) at the eaves beyond the maximum 60 ft. (18,3) span covered by the model V-BB Sprinklers. Refer to the Technical Data Sheets for the model V-BB and V-SD sprinklers for more information. Over 60 - 80ft (18,3 - 24,4 m) 6' (1,83 m) 6' (1,83 m) Maximum 17 Maximum 4'(1,22 m) V-1313 Minimum 10' (3,05 m) V-BB Coverage Maximum Attic Upright Coverage Figure 4: Model V-BB Spinklers Combined with Attic Upright Sprinklers Covering Over 60 to 80 ft. Span Attic Upright sprinklers spaced 7' - 8' (1,8 - 2,4 m) on centers V-SD \ 6' (1,83 m) Maximum 6' (1,83 m) Maximum 4' (1,22 m) Minimum V-SD 10' (3,05 m) Coverage Maximum Attic Upright Coverage Figure 5: Model V-SD Spinklers Combined with Attic Upright Sprinklers Form No. F_042815 18.10.11 Rev 18.2.P65 Page 7 of 7 ® ATTIC UPRIGHT SPECIFIC APPLICATION 4 I KiSPRINKLER VK696 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Refer to Figure 6 below. Requirements: X >_ 3Y or 3Z, X 5 24" (610 mm); Use the larger dimension Y or Z. ELEVATION VIEW PLAN VIEW X Y� Y . r Z X TABLE ATTIC UPRIGHT OBSTRUCTION CRITERIA Horizontal Distance (X) Minimum Vertical Distance Below Deflector (W) <6„ 3" (5152 mm) (77 mm) >6„ - 9„ 4" (>152 - 229 mm) (102 mm) >9„ - 12" 6" (>229 - 305 mm) (89 mm) > 12" - 15" 8" (>305 - 381 mm) (204 mm) >15" - 18" 9-1/2" (>381 - 458 mm) (242 mm) >18" - 24" 12-1/2" (>458 - 610 mm) (318 mm) >24" - 30" 15-1/2" (>610 - 762 mm) (394 mm) >30" 18" (762 mm) (458 mm) Form No. F_042815 18.10.11 Rev 18.2.P65 Replaces Form F_042815 Rev. 18.2 (Added P65 Warning.) *VPOAG III9XIIIIHM LarGq FIOM OI COIIIIIIOIIIl 9AUIIUPIG wGfGL2' ROL 21 ffUIR' I Fbm - 3'a8p P\-rII'. I ru' = 5,� wm' I bzr = 0'Oa PsL 5 (40 gym) I (0*01 PsL) I (0'01 PsL) I (0*01 PsL) I (0'OA PsL) 5 (0'Id Psi) 3 (0'SI Psi) I \s(d0 gym) I (0*01 PsL) I (0'Q1 PsL) 5 (0'1d PsL) S (0'II PsL) d (0'58 PsL) A (0'38 PsL) I (52-m) 5 (0'Id PsL) 3 (0'SI PsL) 3 (0'5I PsL) d (0'38 PsL) 0 (0'3I PsL) IO (0'00 PsL) \*(SO �) a (0'd8 PsL) II (0'a0 Psi) 1,1 (I'R PsL) 55 (1'� P-) 3p (S',f PsL) Ve(IP �) a (0*(?1 PsL) If (0'0d PsL) 18 (I'S PsL) SO (I'8 Psi) 38 (3'(? PsL) (N') 18 -J-R (Q8) 58 (n) 5Q (08) SI OW SO (I18) 25 (1a, ) IgGTGL 8rsc ihi— Mh-) (P\ULTU) 19PIG IQ'4*9) i6m6 mG roRRG2 m b2I III M3j6L ylGcGL2 CPVC PIPE HANGER SUPPORT DOUBLE OFFSET DESIGN Y A!W!-__M C Hanger & surge restraint for horizontal CPVC piping when installed on the side of supporting structure. -For mounting CPVC pipe to wood -Flared edges help protect CPVC -Galvanized steel construction *Supplied with #10 hex head cap screws -Complies with the static load requirements of NFPA® 13 -Suitable for fire protection installations *Size Range: 3/4" through 1" Designed to mount CPVC pipe horizontally or vertically to wood or composite wood joists with a minumum 3/8" thickness. Offset edge eliminates abrasion. Installation: Per NFPA 13, 13R and 13D. Install into wood or steel. Slides onto CPVC pipe. 314 " pipe size I Item #2530181-314 1"pipe size I Item #2530181-1 .�1 an System No. Location Spec Section Paragraph Submitted By Date Approved Date ARGCO.com JrARGCO Updated 4/16/2019 © ARGCO ARGCO.com 600-8 -,0,6 CPVC STRAP TWO HOLE 900 WRAP AROUND AR CO SINCE © 1881 Provides support for CPVC or Polybutalene fire sprinkler piping in fire sprinkler systems installed per NFPA 13, 13R and 13D. -Fastened with a Hardened Hex Head Screw, #10x1-1/2", supplied with the strap. -Pre-galvanized finish. CPVC STRAP TWO HOLE 90° WRAP AROUND ITEM # CPVC PIPE SIZE A B MAX HANGER SPACING CROSS REF TOLCO° ERICO® 2530160-3/4 3/4" ill 2-7/16" 5-1/2" 12722 1070075 2530160-1 1" 1-7/16" 2-11/16" 6" 12746 1070100 2530160-1-1 /4 1-1 /4" 1-5/8" 3-1 /16" 6-1/2" 12753 1070125 2530160-1-1 /2 1-1/2" 1-3/4" 3-5/16" 1 7" 1 12760 1 1070150 2530160-2 2" 1-11 /16" 3-3/4" 1 8" 1 12777 1 1070200 Galvanized carbon steel construction,supplied with hex slotted screws INSTALLATION: 1. Snap CPVC pipe hanger into hanger. Dimples hold pipe in place. 2. Mount hanger onto wood beam with screws provided. 3. Anchor tightly to surface, be sure that pipe can slide freely through hanger. Installation and configuration shall conform to the requirements of the NFPA 13, instructions and applicable local codes. Install with hanger tabs upward only. Do not install on the bottom of a beam or support O under horizontal surface. Hanger for CPVC pipe in the horizontal position on the side of structural wood beams and Steel 20 Ga. (min) with hanger tab in the upward position only. It can also be used AS A GUIDE ONLY to limit movement of vertical CPVC pipe with the tab in the horizontal position. System No. Location Submitted By Date Spec Section Paragraph Approved Date ARGCO.com ARGCO Updated 2/19/2019 0 ARGCO A ARGCO.com 000-854 015 ARGCO CPVC Two -Hole 90 ° Side Mount Strap -Top or bottom beam installation -Galvanized steel, supplied with I" hex screws cSus File VIXH.EX6587 1. Snap CPVC pipe hanger into hanger. Dimples hold pipe in place. 2. Mount hanger onto wood beam with screws provided. 3. May also be used on the underside of beam. 4. Do anchor tightly to surface, be sure that pipe can slide freely through hanger. May be used as a guide in the upward position. Not designed to restrain upward movement of pipe. CROSS REFERENCE Size Item # Tnl Cne I FRicn® 3/4" 25-30-175-3/4 012845 597827 1" 25-30-175-1 012869 597828 1-1/4"IPS 25-30-175-1-1/4 012876 597829 1-1/2" IPS 25-30-175-1-1/2 012883 597831 2"IPS 25-30-175-2 012890 597832 Installation and configuration shall conform to the requirements of the NFPA 13, instructions and applicable local codes. The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM STAND-OFF TWO HOLE STRAP NO BLOCK FOR CPVC AR CO SINCE © 1981 • For mounting CPVC pipe to wood • Flared edges help protect CPVC • Galvanized steel construction • Supplied with #10 x 1" hex head cap screws • Complies with the static load requirements of NFPA® 13 • Suitable for fire protection installations • Eliminates spacers or backup blocks • Easy installation Designed to mount CPVC pipe horizontally or vertically to structural wood members with fasteners provided. Can only be used as a guide on top of beam or on vertical piping. May be installed to wood using supplied fastener or into (minimum 18 gauge) steel using two 1/4" x 1" TEK type screws. Provides vertical/lateral restraint and prevents upward movement of the pipe that supplies pendant fire sprinkler below ceiling. All sizes can be used as a restrainer in the bottom position. The 3/4" size only can be used as a restrainer in the top position. Installation: Per NFPA 13, 13R and 13D. (see page two) Fasteners: Wood - 3/4" to 3" CPVC Pipe - wood screw - no pre -drill Steel - 3/4" to 3" CPVC Pipe - 1/4" TEK screw ARGCO MODEL # 2530180 NPS A B MAX. HANGER SPACING 3/4" 2.69" 3.25" 5.5 ft / 1.68 m 1" 2.94" 3.25" 6 ft / 1.83 m 1-1/4" 3.31" 3.25" 6.5 ft / 1.98 m 1-1/2" 3.56" 4.5" 7 ft / 2.13 m 2" 4.06" 5" 8 it / 2.44 m For use as a restrainer in all sizes when attached to the bottom of structural wood members. For use as a restrainer in the 3/4 inch size when attached to the top of structural wood members System No. Location Submitted By Date O top mount O bottom mount O side mount .25" O O 1" Spec Section Paragraph Approved Date ARGCO.com ARGCO Updated 3/9/2020 © ARGCO A ARGCC.com 900-654-1015 STAND-OFF TWO HOLE STRAP NO BLOCK FOR CPVC M INSTALLATION INSTRUCTIONS AR CO SINCE © 1S_ Designed to mount CPVC pipe to wood or composite wood joists with a minumum 3/8" thickness. 1. Snap strap over CPVC pipe. 2. Squeeze strap back around pipe. Allowing pipe to slide back and forth. 3. Fasten the strap to the wood surface using the two hex head screws provided. NOTE: All sizes can be used as a restrainer in the bottom position. The 3/4" size only can be used as a restrainer in the top position. System No. Location Spec Section Paragraph Submitted By Date Approved Date ARGCO.com VARGCO Updated 3/9/2020 © ARGCO ARGCO CPVC TWO HOLE STRAP cSus File VIXH.EX6587 HEX HEAD SCREWS Designed for support or restraint fo piping in either a vertical or horizon- tal position. It can be used on top or bottom of a beam. The edges are flared to provent any damage to the CPVC pipe. It is easily attached using 2 hex head self -threading screws (supplied) Galvanized steel construction part # size 25-30-283 3/4" 25.30-284 1" 25.30-285 1-1 /4" 25-30-286 1-112" 25-30-287 2" Galvanized steel, supplied with hex slotted screws 1. SNAP CPVC PIPE INTO HANGER. 2. MOUNT HANGER TO UNDERSIDE OF BEAM WITH SCREWS PROVIDED. 3. MAY ALSO BE USED ON TOP SIDE OF BEAM. The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM SUBMITTAL INFORMATION Angle Ball Meter Valves - (BA43-444W-Q-NL style) QUICK JOINT FOR COPPER OR PLASTIC TUBING (CTS) INLET BY METER SWIVEL NUT OUTLET Solid one piece tee -head and stem Sturdy stops allow 90° motion and are enclosed and protected Padlock Wing for locking valve in closed position Dual EPDM O-rings in the stem Fluorocarbon -coated brass ball Molded EPDM rubber seats with reinforcing ring support the ball External Nut Stop Quick Joint Nut A snap ring locks the stem into the body of the valve Bronze Snap Ring r Swivel Nut Meter Coupling Threads t Outlet Height Molded Buna-N Spring Tip Gasket provides Hydraulic Seal Stainless steel Gripper Inlet I-* Length 30 SERVICE LINE METER SIZE APPROX. PART ✓ SUBMITTED VALVE SIZE SIZE INLET OUTLET LENGTH HEIGHT WT. LBS NUMBER ITEM(S) 1" 1" 1" 2-43/64" 2-29/64" 1 3.7 1 BA43-444W-0-NL Note: Ford recommends using insert stiffeners with plastic pipe or tubing. FEATURES • All brass that comes in contact with potable water conforms to AWWA Standard C800 (ASTM B584, UNS C89833) • The product has the letters "NIL" cast into the main body for lead-free identification • Certified to NSF/ANSI Standard 61 and NSF/ANSI Standard 372 where applicable • Brass components that do not come in contact with potable water conform to AWWA Standard C800 (ASTM B62 and ASTM B584, UNS C83600, 85-5-5-5) • Ends are integral or secured with adhesive to prevent unintentional disassembly • Hole for attaching handle is provided in tee -head • 300 PSI working pressure • Padlock Wing for locking valve in closed position • Conforms to AWWA C700 for Meter threads • Meter nut drilled for seal wire Note: Recommended for inlet side shut-off. Optional full 3600 tee -head rotation. Add "R" to end of part number. The Ford Meter Box Company considers the information in this submittal form to be correct at the time of publication. Item and option availability, including specifications, are subject to change without notice. Please verify that your product information is current. The Ford Meter Box Company, Inc. Submitted By: I i P.O. Box 443, Wabash, Indiana U.S.A. 46992-0443 Phone:260-563-3171 / Fax:800-826-3487 Overseas Fax: 260-563-0167 www.fordmeterbox.com 05/16/14 Pressure Loss (psi) CD CD on 406 SUBMITTAL INFORMATION Ball Valve Curb Stop - (B11-444-HT-34-NL style) FEMALE IRON PIPE THREAD INLET BY FEMALE IRON PIPE THREAD OUTLET, WITH HANDLE Solid one piece tee -head/ handle and stem Sturdy stops allow 90° motion and are enclosed and protected \ Dual EPDM O-rings in the stem Female Iron Pipe Thread Inlet — ----------- Length A snap ring locks the stem into the body of the valve Molded EPDM rubber seats with reinforcing ring support the ball 7 Outlet Female Iron Pipe Thread Fluorocarbon -coated brass ball VALVE SIZE INLET SIZE OUTLET SIZE LENGTH APPROX. PART ✓ SUBMITTED WT. LBS NUMBER I ITEM(S) 1"1 1" FEATURES • All brass that comes in contact with potable water conforms to AWWA Standard C800 (ASTM B584, UNS C89833) • The product has the letters "NIL" cast into the main body for lead-free identification • Certified to NSF/ANSI Standard 61 and NSF/ANSI Standard 372 where applicable • Brass components that do not come in contact with potable water conform to AWWA Standard C800 (ASTM B62 and ASTM B584, UNS C83600, 85-5-5-5) • Valve is non -directional and is watertight with flow in either direction • Ends are integral or secured with adhesive to prevent unintentional disassembly • Hole for attaching curb box rod or handle is provided in tee -head • 300 PSI working pressure The Ford Meter Box Company considers the information in this submittal form to be correct at the time of publication. Item and option availability, including specifications, are subject to change without notice. Please verify that your product information is current. The Ford Meter Box Company, Inc. Submitted By: I I P.O. Box 443, Wabash, Indiana U.S.A. 46992-0443 Phone:260-563-3171 / Fax:800-826-3487 Overseas Fax: 260-563-0167 www.fordmeterbox.com 03/29/16 The Ford Meter Box Company, Inc. 11 Wabash, Indiana 46992 Valve flow test performed by Quality Assurance Department March 12, 1992 B11-444 GPM PSI Loss 5 10 15 0.01 20 0.03 25 0.05 30 0.08 35 0.12 40 0.17 45 0.24 50 0.29 A A A � V 0.2 r,'s as 0.1 m CL 010 +Xtl Flow Test Results 10 20 30 40 50 Flow Rate - COPRA Sprinkler Head Adapters BRASTICTm Adapter Straight Tee Size (inches) Part Number Box Qty with metal thread insert 3/4x1/2 V5003SBT-101 100 1 x 1/2 V50035BT-130 50 1 x 3/4 V50035BT-131 50 900 Elbow 3/4x1/2 V50073SBT-101 100 1 x 1/2 V50073SBT-130 50 1 x 3/4 V50073SBT-131 50 Tee 1 x 1 x 1 V50073SBT-101 1 x 1 x 1/2 V50073SBT-130 1 x 1 x 3/4 V50073SBT-131 * Brass starter thread molded into plastic, virtually eliminating cross -threading. 50 50 50 Female Adapter 3/4 x 1/2 V5003SBI-101 100 with metal thread insert 1 x 1/2 V5003SBI-130 50 1 x 3/4 V5003SBI-131 10 Spigot Female Adapter 3/4x 1/2 V50032SBI-101 100 with metal thread insert 1 x 1/2 V50032SBI-130 50 Sprinkler Head 90 1 3/4x 1/2 I V50073SBI-101 100 with metal thread insert 1 x 1/2 1 x 3/4 I V50073561-130 I V50073SBI-131 50 10 1-1/4x1/2 I V50073SBI-166 5 do Size (inches) 1x1x1 3/4 x 3/4 x 1/2 1x1x1/2 1-1/4x 1-1/4x 1/2 1-1/2 x 1-1/2 x 1/2 2x2x1/2 1 x 3/4 x 1/2 1-1/4x 1 x 1/2 1-1/2x 1-1/4x 1/2 2x1-1/2x1/2 Part Number V5012SBI-010 V5012SBI-101 V5012SBI-130 V5012SBI-166 V5012SBI-209 V5012SBI-247 V5012RSBI-124 V5012RSBI-156 V5012RSBI-199 V5012RSBI-237 Back to Back Cross 1xlx1/2x1/2(1-1/8) V50353SBIS-130 with metal thread insert 1x1x1/2x1/2(t-5n6) V50353SBIL-130 in Box Qty 50 10 50 5 5 2 10 5 5 2 20 1 Back to Back Tee 1 /2 x i/2 x 1 (t-va)V501133SBIS-075 30 with metal thread insert 1/2x1/2x1 (1-sne) V501133561L-075 30 4W Trusted above aII.T" V�KING� CPVC Standard Fittings Tee Size (inches) Part Number Box Qty Reducing Tee Size (inches) Part Number Box Qty 3/4 V5011-007 250 I 3/4 x 3/4 x 1 _ V5011 R-102 10 4% 1 V5011-010 100 1 x 3/4 x 3/4 V5011 R-125 100 1-1/4 V5011-012 25 1 x 3/4 x 1 I V5011 R-126 10 1-1/2 V5011-015 25 1 x 1 x 3/4 I V5011 R-131 100 2 V5011-020 2 1-1 /4 x 1 x 3/4 I V5011 R-157 5 2-1/2 V5011-025 1 1-1 /4 x 1 x 1 I V5011 R-158 25 3 V5011-030 1 1-1Ax1x1-1A V5011R-159 5 _ 1-1/4 x 1-1/4 x 3/4 V5011R-167 25 900Elbow 1-1/4 x 1-1/4 x 1 V5011R-168 25 3/4 V5007-007 250 1-1/4x1-1/4x1-1/2 V5011R-169 5 1 V5007-010 100 11-1/2x1-1/4x3/4 V5011R-201 5 1-1/4 V5007-012 25 I 1-1/2 x 1-1/4 x 1 V5011R-202 5 1-1/2 V5007-015 25 1-1/2 x 1-1/2 x 3/4 V5011 R-210 25 2 V5007-020 2 1-1/2 x 1-1/2 x 1 V5011R-211 25 1/2 V5007-025 1 1-1/2x1-1/2x1-1/4 V5011R-212 5 3 E12 V5007-030 1 1-1/2 x 1-1/2 x 2 V5011 R-213 5 x 3/4 V5007R-131 100 2 x 2 x 3/4 V5011 R-248 2 2 x 2 x 1 V5011 R-249 10 450 Elbow 3/4 _ V5006-007 250 2 x 2 x 1-1/4 V5011 R-250 2 1 V5006-010 100 2 x 2 x 1-1/2 V5011 R-251 2 1-1/4 V5006-012 5 2-1/2 x 2-1/2 x 1 V5011 R-289 1 1-1/2 V5006-015 5 2-1/2x2-1/2x1-1/4 V5011R-290 1 2 V5006-020 2 2-1/2 x2-1/2 x 1-1/2 V5011R-291 1 2-1/2 V5006-025 1 2-1/2 x 2-1/2 x 2 V5011 R-292 1 3 V5006-030 1 3 x 3 x 1-1/2 V5011 R-337 1 3 x 2 V5011 R-338 1 Cross 3/4 V5035-007 10 3 x 2-1/2 V5011 R-339 1 1 V5035-010 100 1-1/4 V5035-012 5 Bushing 1 x3/4 V5018-131 100 1-1/2 V5035-015 20 1-1 /4 x 3/4 V5018-167 25 2 V5035-020 1 1-1Ax1 V5018-168 25 2-1/2 V5035-025 1 1-1/2 x 3/4 V5018-210 5 1 x 1 x 3/4 x 3/4 V5035R-131J_ 10 1-1/2 x 1 V5018-211 25 1-1/2x1-1/4 V5018-212 25 Coupling 3/4 V5001-007 250 2 x 3/4 V5018-248 2 1 V5001-01 100 2 x 1 V5018249 2 1-1/4 V5001-012 25 2 x 1-1/4 V5018-250 2 1-1/2 V5001-015 25 2 x 1-1/2 V5018 251 2 2 V5001-020 10 2-1/2x1 V5018-289 15 2-1/2 V5001-025 1 2-1/2 x 1-1/4 V5018-290 1 3 V5001-030 1 2-1/2 x 1-1 /2 V5018-291 1 2-1/2 x 2 V5018-292 1 Reduced Coupling 3 x 1-1/2 V5018-337 15 1 x3/4 V5001R-131 10 3 x 2 V5018-338 1 i 1-1 /4 x 1 V5001 R-168 5 3 x 2-1/2 V5018-339 1 #' 1-1/2 x 3/4 V5001 R-210 5 1-1/2x1 V5001R-211 5 1-1/2x1-1A V5001R-212 5 Cap 3/4 V5017-007 250 2 x 1 V5001 R-249 2 1 V5017-010 100 2x1-1/2 V5001R-251 2 1-1/4 V5017-012� 5 1-1/2 V5017-015 5 2 V5017-020 2 2-1/2 V5017-025 1 3 V5017-030 1 May 2014 CPVC Pipe Size(inches) 11 Part Number 11 Box Qty 3/4 34PIPE 240 1 1 1PIPE 180 1-1/4 114PIPE 105 *l� 1-1/2 112PIPE 75 y 2 _ 2PIPE _ 60 2-1/2 212PIPE _ 30 1 3 3PIPE 15 CPVC Transition Fittings Female Adapter N Size (inches) �I Part Number Box Qty Grooved Coupling Size (inches) Part Number Box Qty with metal thread insert Adapter 3/4 V5003BI-007 10 1-1/4 _V5001G-012 30 J 1 V5003B1-010 50 1-1/2 _V5001G-015 25 J 1-1/4 V5003B1-012 5 2 _V5001G-020 15 J 1-1/2 V5003BI-015 5 2-1/2 V5001G-025 4 2 V5003BI-020 2 3 V5001G-030 2 Spigot Female Adapter 3/4 V50032BI-007 250 Standard Union 3/4 _I V5033E-007 I 1 with metal thread insert 1 V5003261-010 100 � 1 _I V5033E-010 I 1 Male Adapter 3/4 V5004BI-007 10 with metal thread insert 1 V5004BI-010 10 1-1/4 V5004BI-012 5 1-1/2 V5004BI-015 5 2 V5004BI-020 2 Accessories Solvent Cement Size (inches) Part Number Box Qty Dauber Size (inches) Part Number Box Qty Quart V5097Q 12 � Small V5093-5 100 Pint V5097P 12 Large V5093-L 100 Test Plug 1/2 V450-005 50 Roller N/A V5097 24 Brush N/A V5096 12 May 2014 Recommended Installation Practices and Precautions for Freedom® CPVC Systems E Dos MRW • Install product according to the manufacturer's instructions. • Follow recommended safe work practices. • Make certain that thread sealants, gasket lubricants, or fire stop materials are compatible with BlazeMaster® CPVC. • Use only latex -based paints if painting is desired. • Keep pipe and fittings in original packaging until needed. • Cover pipe and fittings with an opaque tarp if stored outdoors. • Follow proper handling procedures. • Use tools designed for use with plastic pipe and fittings. • Use proper solvent cement and follow application instructions. • Use a drop cloth to protect interior finishes. • Cut the pipe ends square. • Deburr and bevel the pipe end before solvent cementing. • When solvent cementing, rotate the pipe 1/4 turn when bottoming pipe in fitting socket. • Always apply solvent cement to the pipe first then fitting. • Avoid puddling of solvent cement in fittings and pipe. • Make certain that solvent cement does not run and plug the sprinkler head orifice. • Follow the manufacturer's recommended cure times prior to pressure testing. • Fill lines slowly and bleed the air from the system prior to pressure testing. • Support sprinkler head properly to prevent lift up of the head through the ceiling when activated. • Keep threaded rod within 1/16"of the pipe. • Install BlazeMaster CPVC pipe and fittings in wet systems only or specially listed dry systems. • Follow manufacturer'hs recommendations for freeze protection. • Allow for movement due to expansion and contraction. • Renew your BlazeMaster CPVC pipe and fittings installation training every two years. • Follow manufacturer's recommendations on pressure testing. • Follow current NFPA standards for use of antifreeze solutions. Blazemaster® is a registered trademark of Lubrizol Teflon® is a registered trademark of E. I. du Pont de Nemours and Company Crisco® is a registered trademark of the J.M. Smucker Company Regional Headquarters Don'ts Iff Do not use petroleum or solvent -based paints, sealants, lubricants or fire stop materials. • Do not use any glycol -based solutions as an anti -freeze. • Do not use both Teflon® tape and thread sealants simultaneously. • Do not use solvent cement that exceeds its shelf life or has become discolored or gelled. • Do not allow solvent cement to plug the sprinkler head orifice. • Do not connect rigid metal couplers to BlazeMaster® CPVC grooved adapters. • Do not thread BlazeMaster CPVC pipe. • Do not use solvent cement near sources of heat, open flame, or when smoking. • Do not pressure test until recommended cure times are met. • Do not use dull or broken cutting tool blades when cutting pipe. • Do not use BlazeMaster CPVC pipe that has been stored outdoors unprotected and is faded in color. • Do not allow threaded rod to come in contact with the pipe. • Do not install BlazeMaster CPVC pipe in cold weather without allowing for expansion. • Do not install BlazeMaster CPVC pipe and fittings in dry systems, unless specifically Listed for such use. • Do not use ratchet cutters below 50•F. • Do not use edible oils such as Crisco® as a gasket lubricant. • Do not install tape, insulated wire, or cable in direct contact with BlazeMaster CPVC pipe. Note:This list does not constitute as a complete installation guide. Viking SupplyNet - U.S. East Viking SupplyNet - U.S. Midwest Viking SupplyNet - U.S. West 4B Cranberry Rd 2353 International St 9101 Sorensen Ave. Parsippany, NJ 07054 Columbus, OH 43228 Santa Fe Springs, CA 90670 Phone: 800-845-4645 Phone: 800-926-7757 Phone: 800-366-1727 Fax: 269-818-1639 Fax: 614-527-5818 Fax: 562-944-1058 Viking SupplyNet - U.S. South Viking SupplyNet - Latin America Viking SupplyNet - Canada 100 Piedmont Court, Suite A 2840 SW 42nd St, Port 95 Ind Ctr Blg IV 325 Vaughan Valley Blvd. Doraville, GA 30340 Hollywood, FL 33312 Woodbridge, Ontario L4H 3135 Phone:800-234-2443 Phone:954-791-1756 Phone:905-856-3557 Fax: 770-446-3713 Fax: 954-791-1614 Fax: 905-856-3558 WARNING: Cancer and Reproductive Harm- www.P65 Warnings.ca.gov May 2014 Viking 1 210 N Industrial Park Drive, Hastings, MI 49058,Telephone: (269) 945-9501, Facsimile: (269) 945-9599 1 www.vikinggroupinc.com MKT-1089 Spears® Technical Information I I-Mar-16 03:20:38 PM Part No: S1520-1000 F1ameGuard® Swing Check Valves Desc: 1 CPVC SWING CHECK VALVE SOC EPDM MSRP: 33.81 Part Code: 004 Weight(lbs):0.41 Weight(kg):0.186 Weight(gm):186 Size: 1 Color: ORANGE Material: CPVC Connection Socket x Socket Type Swing Check Gasket EPDM Note UL Listed A= 1-11/16 B= 2-5/16 C= 4-9/16 D= 2-5/8 Iniection Molded Dimension References: G = (LAYING LENGTH) intersection of center lines to bottom of socket/thread; 90' elbows, tees, crosses; f 1/32 inch. H = Intersection of center lines to face of fitting; 90' elbows tees, crosses; t 1/32 inch. J = Intersection of center lines to bottom of socket/thread; 45' elbows; t 1/32 inch L = Overall length of fittings; t 1/16 inch. M = Outside diameter of socket/thread hub; t 1/16 inch. N = Socket bottom to socket bottom; couplings; t 1/16 inch. W = Height of cap; t 1/16 inch Typical Molded Dimension References The information printed here is based on current information & product design at the time of publication and is subject to change without notification. Spears® ongoing commitment to product improvement may result in some variation. No representation, guarantees or warranties of any kind are as to its accuracy, suitability for particular application or results to be obtained thereform. For verification of technical data or additional information, please contact Spears® Technical Service Department:: WEST COAST : (818) 364-1611 - EAST COAST: (717) 938-9006 NIKJNG4 Plastics Technical Features • Sizes Available (Nominal) : 3/4" (DN20) through 3" (DN80) pipe diameters, with a Standard Dimension Ratio (SDR) of 13.5 as specified in ASTM F442. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Hazen -Williams C Value: 150 • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150OF (65°C) • Specifications - Meets NFPA 13, 13R and 13D standards for light hazard occupancies. Pipe meets or exceeds ASTM F442. - Approved for National Sanitation Foundation (NSF) potable water services - CPVC Pipe from Viking SupplyNet complies to NSF cell class 23547 (demonstrated highest structural properties). - Meets LPC Sprinkler Rules requirements BlazeMaster° CPVC Pipe VIKING SupplyNef OFMc L us0LPCB';P° NSF WRASAPPROVER LISTED'F"' * LPCB Approved up to and including 2" n n 7M rrM Physical Data Nominal Pipe Size Actual Outside Diameter Average I.D. (inch / mm) Weight per 15' (4.6m) length (Ib / kg) Length (� / m) Approvals Part Number inch metric inch mm 3/4" DN20 1.050 26,670 0.874 / 22,199 2.52 / 1,14 15 / 4,6 cULus, FM, LPCB', WRAS, NSF 34PIPE 1" DN25 1.315 33,401 1.101 / 27,965 3.93 / 1,78 15 / 4,6 1 PIPE 11/4" DN32 1.660 42,164 1.394 / 35,408 6.27 / 2,84 15 / 4,6 114PIPE 11/2" DN40 1.900 48,260 1.598 / 40,589 8.22 / 3,73 15 / 4,6 112PIPE 2" DN50 2.375 60,325 2.003 / 50,876 12.89 / 5,85 15 / 4,6 2PIPE 2'/2" DN65 2.875 73,000 2.423 / 61,500 18.86 / 8,55 15 / 4,6 212PIPE 3" DN80 3.500 88,900 2.950 / 74,900 28.01 / 12,71 15 / 4,6 3PIPE Nominal Pipe Size Actual Outside Diameter Average I.D. (inch / mm) Weight per 10' (3,05m) length (lb / kg) Length (ft / m) Approvals Part Number inch metric inch mm 3/4" DN20 1.050 26,670 0.874 / 22,199 1.68 / 0,76 10 / 3,05 cULus, FM, LPCB*, WRAS, NSF 34PIPE10 1" DN25 1.315 33,401 1.101 / 27,965 2.62 / 1,19 10 / 3,05 1 PIPE10 11/4" DN32 1.660 42,164 1.394 / 35,408 4.18 / 1,90 10 / 3,05 114PIPE10 1 %" DN40 1.900 48,260 1.598 / 40,589 5.48 / 2,49 10 / 3,05 112PIPE10 2" DN50 2.375 60,325 2.003 / 50,876 8.59 / 3.90 10 / 3,05 2PIPE10 2'/2" DN65 2.875 73,000 2.423 / 61,500 12.57 / 5,70 10 / 3,05 212PIPE10 3" DN80 3.500 88,900 2.950 / 74,900 18.67 / 8,47 10 / 3,05 3PIPE10 Note: CPVC Pipe is produced in SDR 13.5 Dimensions in accordance with ASTM F442. Standard Dimension Ratio is the ratio of the outside pipe diameter to the wall thickness of the pipe. ' Approved up to and inducing 2" IMPORTANT: Installers should receive thorough hands-on training in the proper methods of assembly and installation of CPVC products. On -site training is available at no charge from Viking SupplyNet. Participants in the training program will receive a special card acknowledging their attendance. In addition to receiving proper training, installers must always consult the Manufacturer's Design and Installation Guide before any installation project is commenced. Worldwide Fire Protection www.vikinggroupinc.com rc ... e. .9r.+aTA�.. �nr .MIMMUn .. aemr_arramm�,.,mrtmmrs�rr-+maw=rmars+mrrmnarrarr�trrrrn.�mamamm NIKJNG4 Plastics VIKING SupplyNef BlazeMaster® CPVC Pipe Product Specifications Corrosion resistance CPVC fire sprinkler pipe, when installed in strict accordance with the manufacturers design and installation instructions, are UL and C-UL Listed by Underwriters Laboratories for use in the following: • Light Hazard occupancies as defined in the Standard for Installation of Sprinkler Systems, NFPA 13. • Residential occupancies up to and including four stories in height as defined by NFPA 13R. • Residential occupancies as defined in the Standard for Sprinkler Systems in One and Two Family Dwellings, NFPAI3D. • Installation of private fire service mains and their appurtenances, NFPA 24. CPVC fire sprinkler pipe from Viking SupplyNet shall be employed in wet pipe systems only and are not listed for outdoor use. CPVC pipe must never be used in a system using compressed air or other gases. CPVC pipe from Viking SupplyNet also carries the following enhanced listings and approvals: • According to UL Listed (UL 1821) • Can be flush at return air plenums • Mechanical cut -in tee 8. crosses concealed with Grinnell figure 730 fittings • Mechanical cut -in tee 8, crosses exposed with Grinnell figure 730 fittings • Exposed system risers NFPA 13D, 13R • Exposed basement NFPA 13D (solid wood joist) • Extended coverage (exposed) • 20' spacing on pendent in lieu of 15' • 18' spacing on sidewall in lieu of 14' • Use with combustible concealed sprinklers • Tyco attic sprinkler head (to protect the floor below) • Tyco attic sprinkler head with wet system piping (feed main and ridge installation) • Exposed sidewall sprinkler Listing for exposed pipe 8, fittings • 24' extended coverage sidewall sprinkler, 12" drop, 155°F sprinkler head • 18' extended coverage sidewall sprinkler, 12" drop, 165°F sprinkler head • 16' extended coverage sidewall sprinkler, 12" drop, 1757 sprinkler head • 14' standard coverage sidewall sprinkler, 12" drop, 200°F sprinkler head • Factory Mutual Approved* • Factory Mutual Approval exposed • Factory Mutual Approval above drop -in ceilings • Factory Mutual Approval exposed w/ Soffi-Steel soffiting covering system • LPCB Approval • WRAS Approval The above data is based on UL and FM reported Listings and Approvals as of 11/30/05. New and enhanced listings and approvals are being pursued. Always check with the appropriate Listing and Approval agency for details on current listing parameters. CPVC pipe also meets all applicable standards for pressure rated application as required in ANSI -NSF Standard 14 and complies with ANSI -NSF Standard 61 for health effects and are marked with the NSF-pw end us marking. Viking Plastics CPVC Pipe is manufactured from WRAS approved Blazemaster® compound All CPVC fire sprinkler pipe shall be Listed by Underwriters Laboratories for wet pipe systems, and shall carry a rated working pressure of 175 psi @ 150°F (12 bar @ WC). The FM Approval is limited to use in wet pipe fire protection sprinkler systems for light hazard occupancies in both concealed and exposed applications with certain restrictions. Piping must always be installed in strict accordance to the manufacturers System Design and Installation Manual, including product stor- age and handling, joining methods, supporting and bracing, expansion and contraction allowance and testing, etc. National Fire Protection Association (NFPA) Standards 13, 13D, and 13R or LPC Sprinkler Rules Technical Bulletins, must be referenced for design and installation requirements in conjunction with the installation instructions. All CPVC fire sprinkler pipe from Viking SupplyNet is manufactured in the USA by an ISO 9001 certified manufacturer. All CPVC pipe shall be packaged immediately after its manufacture to prevent damage and shall be stored indoors after production, at the manufactur- ing site, until shipped from the factory. The pipe shall bear the logo of the listing agencies, and shall carry the National Sanitation Founda- tion (NSF) seal of approval for potable water applications. CPVC products are intended for use in areas where the maximum ambient temperature does not exceed 150OF (66°0. If the ambi- ent temperature is expected to exceed this limitation, refer to the manufacturers System Design and Installation Manual for additional information on methods to reduce the pipe exposure temperatures. CPVC pipe is not intended to be installed in outdoor applications. CPVC pipe is intended to beused in wet pipe systems only and have not been investigated for use in dry pipe systems. Special installation and design criteria relative to pipe hanger spacings, piping and sprinkler restraint, sprinkler temperature rating, piping locations, testing procedures and friction loss characteristics are specified in the manufacturers installation instructions provided with the pipe. The manu- facturers installation instructions should be reviewed and the Authority Having Jurisdiction consulted before installation. Worldwide Fire Protection n n KID: 7 1 rho www.vikinggroupinc.com rc ... e. .9r.+aTA�.. �nr .MIMMUn .. aemr_arramm�,.,mrtmmrs�rr-+maw=rmars+mrrmnarrarr�trrrrn.�mamamm Socket x Socket x Socket Technical Features • Sizes Available (Nominal) : See table below. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 1'/4" (DN32) and in Schedule 80 for sizes 1'/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65'0 for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. NIKJNG4 SupplyNef FM c �L us NSF. 3 WRAS OLPCB' APPOOVED LPCB Approved up to and including 2" " Approval pending. n n 7M rrM Reducing Tee - Socket x Socket x Socket Physical Data Nominal Pipe Size Dimensions (mm / inch) Approx. Weight (lbs. / kgs.) Part Number inch metric A B 3/4" x 3/4" x 1" DN20 x DN20 x DN25 / 0.70 / 0.70 / 0.73 0.15 / 0.068 V5011 R-102 1" x 3/4" x 3/4" DN25 x DN20 x DN20 / 0.74 / 0.80 / 0.84 0.15 / 0.068 V5011 R-125 1" x 3/4" x 1" DN25 x DN20 x DN25 / 0.74 / 0.91 / 0.73 0.22 / 0.100 V5011 R-126 1" x 1" x 3/4" DN25 x DN25 x DN20 / 0.61 / 0.61 / 0.94 0.13 / 0.059 V5011 R-131 11/4" x 1" x 3/4" DN32 x DN25 x DN20 / 0.74 / 0.60 / 0.89 0.20 / 0.091 V5011 R-157 1'/4" x 1" x 1" DN32 x DN25 x DN25 / 0.90 / 0.71 / 0.89 0.24 / 0.110 V5011 R-158 1'/4" x 1" x 1'/4" DN32 x DN25 x DN32 / 1.00 / 0.91 / 0.87 0.28 / 0.130 V5011 R-159 1'/4" x 1'/41,x 3/4" DN32 x DN32 x DN20 / 0.60 / 0.60 / 0.89 0.21 / 0.095 V5011 R-167 1'/4" x 1'/4" x 1" DN32 x DN32 x DN25 / 0.72 / 0.72 / 0.89 0.13 / 0.059 V5011 R-168 1'/4" x 1'/4" x 1'/2" DN32 x DN32 x DN40 / 1.00 / 1.00 / 0.88 0.42 / 0.191 V5011 R-169 1'/2" x 11/4" x 3/4" DN40 x DN32 x DN20 / 0.76 / 0.62 / 1.02 0.35 / 0.159 V5011 R-201 1'/2" x 1'/4" x 1" DN40 x DN32 x DN25 / 0.88 / 0.74 / 1.01 0.39 / 0.177 V5011 R-202 11/2" x 1'/2"x 3/4" DN40 x DN40 x DN20 / 0.76 / 0.76 / 1.31 0.48 / 0.172 V5011 R-210 1'/2" x 1'/2"x 1" DN40 x DN40 x DN25 / 0.77 / 0.77 / 1.29 0.52 / 0.236 V5011 R-211 1'/z" x 11/2" x 1'/4" DN40 x DN40 x DN32 / 0.87 / 0.87 / 1.04 0.47 / 0.213 V5011 R-212 1'/2" x 1'/2" x 2" DN40 x DN40 x DN50 / 1.30 / 1.29 / 1.14 0.67 / 0.304 V5011 R-213 2" x 2" x 3/4" DN50 x DN50 x DN20 / 0.67 / 0.67 / 1.56 0.65 / 0.295 V5011 R-248 2" x 2" x 1" DN50 x DN50 x DN25 / 0.77 / 0.77 / 1.55 0.69 / 0.313 V5011 R-249 2" x 2" x V/z" DN50 x DN50 x DN40 / 1.04 / 1.04 / 1.29 0.83 / 0.376 V5011 R-251 2'/2" x 2'/z" x 1" DN65 x DN65 x DN25 / 1.53 / 1.53 / 2.59 1.87 / 0.848 V5011 R-289 2'/z" x 21/2" x 1'/4" DN65 x DN65 x DN32 / 1.53 / 1.53 / 2.47 1.90 / 0.862 V5011 R-290 VW x 21/2" x 1'/2" DN65 x DN65 x DN40 / 1.53 / 1.53 / 2.08 1.86 / 0.844 V5011 R-291 3" x 3" x 2" DN80 x DN80 x DN50 / 1.34 / 1.34 / 1.82 1.73 / 0.785 V5011 R-338 3" x 3" x 2'/2" DN80 x DN80 x DN65 / 1.84 / 1.84 / 2.55 2.90 / 1.320 V5011 R-339 Refer to the "CPVC Equal Tee" datapage or manufacturer's installation instructions for friction loss information. Worldwide Fire Protection www.vikinggroupinc.com s 0 N Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturers datasheet. Specifications subject to change without notice. Socket x Socket x Socket Technical Features • Sizes Available (Nominal) : 3/4" (DN20) through 3" (DN80) pipe diameters. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 1'/4" (DN32) and in Schedule 80 for sizes 1'/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. NIKJNG* SupplyNef FM c&us NSF 3 N'RAS (LP)CB APPROVED Ear * LPCB Approved up to and including 2" ** Approval pending. n n 7M Equal Tee - Socket x Socket x Socket Physical Data Nominal Pipe Size Dimensions (mm / inch) Approx. Weight (lbs. / kgs.) Part Number inch metric A B C 3/4" DN20 / 0.56 / 0.56 / 0.56 0.09 / 0.04 V5011-007 1" DN25 / 0.69 / 0.69 / 0.69 0.15 / 0.07 V5011-010 11/4" DN32 / 0.89 / 0.89 / 0.89 0.30 / 0.14 V5011-012 1'/2" DN40 / 1.06 / 1.06 / 1.06 / 1.27 / 1.53 / 1.84 0.73 / 0.33 V5011-015 2" DN50 / 1.27 / 1.27 1.05 / 0.48 V5011-020 2'/2" DN65 / 1.53 / 1.53 1.59 / 0.72 V5011-025 3" DN80 / 1.84 / 1.84 2.38 / 1.10 V5011-030 CPVC Fittings Allowances for Friction Loss in Fittings Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90* Elbow 45° Elbow Coupling 3/4" DN20 1 /0.3 3/0.9 7/2.1 1 /0.3 1 /0.3 1" DN25 1 /0.3 5/1.5 7/2.1 1 /0.3 1 /0.3 11/4" DN32 1/0.3 6/1.8 8/2.4 2/0.6 1/0.3 1'/2" DN40 1 /0.3 DN50 1 /0.3 8 / 2.4 9 / 2.7 2/0.6 11 /3.4 2/0.6 1 /0.3 1 /0.3 2" 10/3.1 2'/2" DN65 2/0.6 12/3.7 12/3.7 3/0.9 2/0.6 3" DN80 2/0.6 15 / 4.6 13 / 4.0 4 / 1.2 2/0.6 Worldwide Fire Protection www.vikinggroupinc.com Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer's datasheet. Specifications subject to change without notice. Socket x Socket x NPT Thread Technical Features • Sizes Available (Nominal) : See table below. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature: 150°F (65'0 • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Threaded Connections : 1 female threaded NPT outlet. • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 1'/4" (DN32) and in Schedule 80 for sizes 11/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.5 bar) at 150°F (65'0 for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. NIKJNG4 SupplyNef FM c&us NSF. 3 WRAS OLPCB' APPROVE LPCB Approved up to and including 2" " Approval pending. n n 7M rrM Sprinkler Head Tee (Metal Thread Insert) - Socket x Socket x NPT Thread Physical Data Nominal Pipe Size Dimensions (inch) Approx. Weight (lbs. / kgs) Part Number inch metric g BA=h C 3/4" x 3/4- x'/z" DN20 x DN20 x DN15 / 0.42 / 0.42 / 1.60 0.22 / 0.100 V5012SBI-101 1" x 3/41, x'/z" DN25 x DN20 x DN15 / 0.43 / 0.83 / 1.69 0.27 / 0.125 V5012RSBI-124 1" x 1" x'/z" DN25 x DN25 x DN15 / 0.42 / 0.42 / 1.76 0.28 / 0.127 V5012SBI-130 1" x 1" x 1" DN25 x DN25 x DN25 / 0.83 / 0.83 / 1.48 0.43 / 0.195 V5012SBI-010 1'/4" x 1" x'/z" DN32 x DN25 x DN15 / 0.51 / 0.63 / 1.94 0.33 / 0.149 V5012RSBI-156 11/4" x 1'/4" x'/z" DN32 x DN32 x DN15 / 0.51 / 0.51 / 1.95 0.33 / 0.149 V5012SBI-166 11/2" x 1'/4" x'/z" DN40 x DN32 x DN15 / 0.45 / 0.67 / 2.13 0.47 / 0.213 V5012RSBI-199 11/2" x 1'/2" x'/z" DN40 x DN40 x DIN 15 / 0.45 / 0.45 / 2.13 0.47 / 0.213 V5012SBI-209 2" x 1'/z" x'/z" DN50 x DN40 x DN15 / 0.62 / 0.82 / 2.38 0.58 / 0.263 V5012RSBI-237 2" x 2" x'/z" DN50 x DN50 x DN15 / 0.50 / 0.50 / 1.68 0.58 / 0.263 V5012SBI-247 CPVC Fittings Allowances for Friction Loss in Fittings Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45' Elbow Coupling 3/4" DN20 1 /0.3 3 / 0.9 7 / 2.1 1 /0.3 1 /0.3 1" DN25 1 /0.3 5/1.5 7/2.1 1 /0.3 1 /0.3 1'/4" DN32 1 /0.3 6/1.8 8/2.4 2/0.6 1 /0.3 1'/2" DN40 1 /0.3 8 / 2.4 9 / 2.7 2 / 0.6 1 /0.3 2" DN50 1 / 0.3 10 / 3.1 11 / 3.4 2 / 0.6 1 / 0.3 2'/2" DN65 2 / 0.6 12 / 3.7 12 / 3.7 3 / 0.9 2 / 0.6 3" DN80 2 / 0.6 15 / 4.6 13 / 4.0 4 / 1.2 2 / 0.6 V �1111111111111F 1� Worldwide Fire Protection qrr www.vikinggroupinc.com Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturers datasheet. Specifications subject to change without notice. Socket x NPT Thread x Socket Technical Features • Sizes Available (Nominal) : 1" (DN25) x'/2" (DN15) x 1" (DN25) • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65"0 • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Threaded Connections : 1 female threaded NPT outlet. • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 11/4" (DN32) and in Schedule 80 for sizes 1'/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65"0 for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. NIKJNG* SupplyNef FM c �L us NSF WWRAS OLPCB' APPAOVEA a * LPCB Approved up to and including 2" ** Approval pending. n n 7M Sprinkler Head Tee (Metal Thread Insert) - Socket x NPT Thread x Socket Physical Data Nominal Pipe Size Dimensions (mm / inch) Approx. Weight (lbs. / kgs.) Part Number inch 77 metric A B C 1" x'/2" x 1" DN25 x DN15 x DN25 / / / 0.25 / 0.113 V5012RSBI-122 CPVC Fittings Allowances for Friction Loss in Fittings Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90o Elbow 45° Elbow Coupling 3/4" DN20 1 /0.3 3/0.9 7/2.1 1 /0.3 1 /0.3 1" DN25 1 /0.3 5/ 1.5 7/2.1 1 /0.3 1 /0.3 11/4" DN32 DN40 1 /0.3 1 /0.3 6/ 1.8 8/2.4 9/2.7 2/0.6 2/0.6 1 /0.3 1 /0.3 1'/2" 8/2.4 2" DN50 1 /0.3 10/3.1 11 /3.4 2/0.6 1 /0.3 21/z" DN65 2/0.6 12/3.7 12/3.7 3/0.9 2/0.6 3" DN80 2/0.6 15/4.6 13/4.0 4/1.2 2/0.6 Worldwide Fire Protection www.vikinggroupinc.com Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer's datasheet. Specifications subject to change without notice. NPT Thread x NPT Thread x Socket Technical Features • Sizes Available (Nominal) :'/2" ON15) pipe run with 1" (DN25) outlet. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65"0 • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 1507 (65°C) • Threaded Connections : 2 female threaded NPT inlets. • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 1'/4" (DN32) and in Schedule 80 for sizes 1'/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150OF (65'0 for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. NIKJNG* SupplyNef FM c&us NSF WWRAS OLPCB' APPROVED a * LPCB Approved up to and including 2" ** Approval pending. n n 7M Sprinkler Head Tee - Sidewall (Metal Thread Inserts) - NPT x NPT x Socket Physical Data Nominal Pipe Size Dimensions (mm / inch) Approx. Weight (lbs. / kgs.) Part Number inch metric A B =C '/2" x'/2" x 1" I DN15 x DN15 x DN25 / 1.18 / 1.18 / 0.62 0.48 / 0.217 V501133SBIS-075 CPVC Fittings Allowances for Friction Loss in Fittings Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90* Elbow 45' Elbow Coupling 3/4" 1" DN20 1 /0.3 DN25 1 /0.3 3/0.9 7/2.1 1 /0.3 1 /0.3 5/1.5 7/2.1 1 /0.3 1 /0.3 1'/4" DN32 1 /0.3 6/1.8 8/2.4 2/0.6 1 /0.3 1'/2" DN40 1 /0.3 8 / 2.4 9 / 2.7 2/0.6 1 /0.3 2" DN50 1 /0.3 10/3.1 11 /3.4 2/0.6 1 /0.3 2'/2" DN65 2/0.6 12/3.7 12/3.7 3/0.9 2/0.6 3" DN80 2/0.6 15 / 4.6 13 / 4.0 4 / 1.2 2/0.6 Worldwide Fire Protection www.vikinggroupinc.com Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer's datasheet. Specifications subject to change without notice. Socket x Socket Technical Features • Sizes Available (Nominal) : See tables below. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature: 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 1'/4" (DN32) and in Schedule 80 for sizes 11/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are LIL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150OF (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. * LPCB Approved up to and including 2" ** Approval pending. NIKJNG4 SupplyNef n n BOW • B A REDUCING ELBOW ** FM c uL us ll$f. ; WRAS LPCB APPAOV® "Ea KID: 7M 90° Elbow - Socket x Socket Physical Data Nominal Pipe Size Dimensions (mm / inch) Approx. Weight (Ibs. / kgs.) Part Number inch metric A B 3/4" DN20 / 0.56 / 0.56 0.06 / 0.022 V5007-007 1" DN25 / 0.69 / 0.69 0.09 / 0.034 V5007-010 1'/4' DN32 / 0.91 / 0.91 0.16 / 0.059 V5007-012 1'/2" DN40 / 1.06 / 1.06 0.50 / 0.187 V5007-015 2" DN50 / 1.24 / 1.24 0.70 / 0.261 V5007-020 2'/2" DN65 / 1.50 / 1.50 1.16 / 0.433 V5007-025 3" DN80 / 1.81 / 1.81 1.82 / 0.679 V5007-030 Reducing 90° Elbow - Socket x Socket Physical Data Nominal Pipe Size Dimensions (mm / inch) Approx. Weight A B (Ibs. / kgs.) Part Number inch metric 1" x 3/4' DN25 x DN32 / 0.61 / 0.75 0.12 / 0.045 V500711-131 CPVC Fittinas Allowances for Friction Loss in Fittinas Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90* Elbow 45• Elbow Coupling 3/4' DN20 1 /0.3 3/0.9 7/2.1 1 /0.3 1 /0.3 1" DN25 1 /0.3 5/ 1.5 7/2.1 1 /0.3 1 /0.3 11/4" DN32 1 /0.3 6/ 1.8 8/2.4 2/0.6 1 /0.3 1'/z" DN40 1 /0.3 8 / 2.4 9 / 2.7 2/0.6 1 /0.3 2" DN50 1 /0.3 10/3.1 11 /3.4 2/0.6 1 /0.3 2'/z" DN65 2/0.6 12 / 3.7 12 / 3.7 3 / 0.9 2/0.6 3" DN80 2/0.6 15/4.6 13/4.0 4/1.2 2/0.6 Worldwide Fire Protection r�www.vikiinqgroupinc.corn s 0 N Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturers datasheet. Specifications subject to change without notice. Socket x NPT Thread Technical Features • Sizes Available (Nominal) : 3/4" (DN20) through V/4" (DN32) run,'/2" (DN15) and 3/4" (DN20) outlet. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65"0 • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Threaded Connections : 1 female threaded NPT outlet. • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 11/4" (DN32) and in Schedule 80 for sizes 1'/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150OF (6500 for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. NIKJNG* SupplyNef FM c&us NSF 3 N'RAS (LP)CB APPROVED Ear * LPCB Approved up to and including 2" ** Approval pending. n n n (D Kle: 7M Sprinkler Head 90° Elbow (Metal Thread Insert) - Socket x NPT Thread Physical Data Nominal Pipe Size Dimensions (mm / inch) Approx. Weight (lbs. / kgs.) Part Number inch metric A B 3/4" x'/2" DN20 x DN15 1" x'/2" DN25 x DN15 1" x 3/4" DN25 x DN20 / 0.56 / 0.50 / 0.59 / 1.62 / 1.75 / 1.88 0.22 / 0.099 0.27 / 0.122 0.27 / 0.122 V50073SBI-101 V50073SBI-130 V50073SBI-131 1'/4" x'/2" DN32 x DN15 / 0.48 / 1.95 1.86 / 0.844 V50073SBI-166 CPVC Fittings Allowances for Friction Loss in Fittings Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90* Elbow 45* Elbow Coupling 3/4" DN20 1 /0.3 3/0.9 7/2.1 1 /0.3 1 /0.3 1" 1'/4" DN25 1 /0.3 DN32 1 /0.3 5/ 1.5 6/ 1.8 7/2.1 8/2.4 1 /0.3 2/0.6 1 /0.3 1 /0.3 1'/2" DN40 1 /0.3 8/2.4 9/2.7 2/0.6 1 /0.3 2" DN50 1 /0.3 10/3.1 11 /3.4 2/0.6 1 /0.3 2'/2" DN65 2/0.6 12/3.7 12/3.7 3/0.9 2/0.6 3" DN80 2/0.6 15/4.6 13/4.0 4/1.2 2/0.6 Worldwide Fire Protection wwwmikinggroupinc.com Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer's datasheet. Specifications subject to change without notice. Socket x Socket Technical Features • Sizes Available (Nominal) : 3/4" (DN20) through 3" (DN80) pipe diameters. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature: 1507 (65"0 • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 1'/4" (DN32) and in Schedule 80 for sizes 1'/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150OF (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. NIKJNG4 SupplyNef FM c@us NSF. 3 WRAS OLPCB' APPROVE LPCB Approved up to and including 2" " Approval pending. n n 7M rrM 45' Elbow - Socket x Socket Physical Data Nominal Pipe Size inch metric Dimensions (mm / inch) Approx. Weight Ubs. / kgs.) Part Number J 3/4" DN20 / 0.32 0.06 / 0.027 V5006-007 I DN25 / 0.39 0.12 / 0.054 V5006-010 11/4" DN32 / 0.48 0.17 / 0.0794 V5006-012 1'/2" DN40 / 0.47 0.41 / 0.190 V5006-015 2" DN50 / 0.58 0.62 / 0.280 V5006-020 2'/2' DN65 / 0.65 0.93 / 0.420 V5006-025 3" DN80 / 0.76 1.39 / 0.630 V5006-030 CPVC Fittings Allowances for Friction Loss in Fittings Nominal Pipe Size Equivalent Feet / Meters of Pipe i2Gh metric Tee Run Tee Branch 90• Elbow 45• Elbow Coupling 3/4' DN20 1/0.3 3/0.9 7/2.1 1 /0.3 1/0.3 1" DN25 1/0.3 5/1.5 7/2.1 1/0.3 1/0.3 1'/4" DN32 1/0.3 6/ 1.8 8/2.4 2/0.6 1/0.3 1'/z" DN40 1/0.3 8 / 2.4 9 / 2.7 2/0.6 1 / 0.3 2" DN50 1/0.3 10/3.1 11 /3.4 2/0.6 1/0.3 21/z' DN65 2/0.6 12 / 3.7 12 / 3.7 3 / 0.9 2/0.6 3" DN80 2/0.6 15/4.6 13/4.0 4/1.2 2/0.6 Worldwide Fire Protection ri_ www.vikinggroupinc.com Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturers datasheet. Specifications subject to change without notice. Socket x Socket x Socket x Socket Technical Features • Sizes Available (Nominal) : See tables below. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65"0 • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 1'/4" (DN32) and in Schedule 80 for sizes 1'/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150OF (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. NIKJNG4 SupplyNef FM c&us NSF. 3 WRAS OLPCB' APPROVE LPCB Approved up to and including 2" " Approval pending. n n 7M rrM Cross - Socket x Socket x Socket x Socket Physical Data Nominal Pipe Size Dimensions (mm / inch) Approx. Weight A B (Ibs. / kgs.) IL Part Number inch metric 3/4" DN20 / 0.60 / 0.60 0.13 / 0.059 V5035-007 1" DN25 / 0.74 / 0.74 0.25 / 0.113 V5035-010 11/4" DN32 / 0.90 / 0.90 0.35 / 0.159 V5035-012 11/1" DN40 / 1.23 / 1.23 0.69 / 0.313 V5035-015 2" DN50 / 1.53 / 1.53 1.02 / 0.463 V5035-020 21/2" DN65 / 1.75 / 1.75 1.70 / 0.771 V5035-025 Reducing Cross - Socket x Socket x Socket x Socket Physical Data Nominal Pipe Size Dimensions (mm / inch) Approx. Weight (Ibs. / kgs.) Part Number inch metric A B 1" x 1" x 3/4" x 3/4" 1 DN25 x DN25 x DN20 x DN20 / 0.60 / 0.72 0.18 / 0.082 V5035-131 CPVC Fittings Allowances for Friction Loss in Fittings Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90' Elbow 45° Elbow Coupling 3/4" DN20 1 /0.3 3 / 0.9 7 / 2.1 1 /0.3 1 /0.3 1" DN25 1 /0.3 5/1.5 7/2.1 1 /0.3 1 /0.3 1'/4" DN32 1 /0.3 6/1.8 8/2.4 2/0.6 1 /0.3 1'/2- DN40 1 / 0.3 8 / 2.4 9 / 2.7 2/0.6 1 /0.3 2" DN50 1 /0.3 10/3.1 11 /3.4 2/0.6 1 /0.3 2'/2" DN65 2/0.6 12 / 3.7 12 / 3.7 3 / 0.9 2/0.6 3" DN80 2/0.6 15 / 4.6 13 / 4.0 4 / 1.2 2/0.6 Worldwide Fire Protection www.vikinggroupinc.com Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturers datasheet. Specifications subject to change without notice. Socket x Socket x NPT Thread x NPT Thread Technical Features • Sizes Available (Nominal) : See table below • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150OF (65°C) • Threaded Connections : 2 female threaded NPT outlets. • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 1'/4" (DN32) and in Schedule 80 for sizes 1'/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. NIKJNG* SupplyNef FM c&us NSF 3 N'RAS (LP)CB APPROVED Ear * LPCB Approved up to and including 2" ** Approval pending. n n 7M Sprinkler Head Cross - Sidewall (Metal Thread Inserts) - Soc x Soc x NPT x NPT Physical Data Nominal Pipe Size Dimensions (mm / inch) Approx. Weight Part Number inch metric A B C D (lbs. / kgs.) 1" x 1" x'/2" x'/2" DN25 x DN25 x DN15 x DN15 / 1.18 / 1.18 / 0.62 / 0.62 0.46 / 0.209 V50353SBIS-130 CPVC Fittings Allowances for Friction Loss in Fittinqs Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45* Elbow Coupling 3/4" DN20 1 /0.3 3/0.9 7/2.1 1 /0.3 1 /0.3 1" DN25 1/0.3 5/1.5 7/2.1 1/0.3 1/0.3 11/4" DN32 1 /0.3 6/ 1.8 8/2.4 2/0.6 1 /0.3 1'/2" DN40 1 /0.3 8/2.4 9/2.7 2/0.6 1 /0.3 2" DN50 1 /0.3 10/3.1 11 /3.4 2/0.6 1 /0.3 2'/2" DN65 2/0.6 12/3.7 12/3.7 3/0.9 2/0.6 3" DN80 2/0.6 15 / 4.6 13 / 4.0 4 / 1.2 2/0.6 Worldwide Fire Protection www.vikinggroupinc.com Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer's datasheet. Specifications subject to change without notice. Socket x Socket Technical Features • Sizes Available (Nominal) : 3/4" (DN20) through 3" (DN80) pipe diameters. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature: 150°F (65'0 • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 1'/4" (DN32) and in Schedule 80 for sizes 11/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150OF (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. NIKJNG4 SupplyNef FM c&us NSF. 3 WRAS OLPCB' APPROVE LPCB Approved up to and including 2" " Approval pending. n n 7M P'h P'h (M Coupling - Socket x Socket Physical Data Nominal Pipe Size Dimensions [mm / inch) Approx. Weight Obs. / kgs.) Part Number inch metric A 3/4" DN20 / 0.10 0.05 / 0.023 V5001-007 1" DN25 / 0.09 0.08 / 0.036 V5001-010 11/4" DN32 / 0.10 0.13 / 0.059 V5001-012 1'/2" DN40 / 0.24 0.37 / 0.168 V5001-015 2" DN50 / 0.19 0.52 / 0.236 V5001-020 2'/2" DN65 / 0.13 0.68 / 0.308 V5001-025 3" DN80 / 0.16 1.05 / 0.476 V5001-030 CPVC Fittings Allowances for Friction Loss in Fittings Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45• Elbow Coupling 3/4" DN20 1 / 0.3 3 / 0.9 7 / 2.1 1 / 0.3 1 / 0.3 1" DN25 1/0.3 5/1.5 7/2.1 1/0.3 1/0.3 11/4" DN32 1/0.3 6 / 1.8 8 / 2.4 2 / 0.6 1/0.3 1'/2" DN40 1/0.3 8 / 2.4 9 / 2.7 2 / 0.6 1/0.3 2" DN50 1/0.3 10/3.1 11 /3.4 2/0.6 1/0.3 2'/2" DN65 2 / 0.6 12 / 3.7 12 / 3.7 3 / 0.9 2 / 0.6 3" DN80 2 / 0.6 15 / 4.6 13 / 4.0 4 / 1.2 2 / 0.6 Worldwide Fire Protection www.vikinggroupinc.com Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturers datasheet. Specifications subject to change without notice. Socket x Socket Technical Features • Sizes Available (Nominal) : 1" (DN25) through 2'/2" (DN65) inlet, 3/4" (DN20) through 2" outlet. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150OF (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 1'/4" (DN32) and in Schedule 80 for sizes 11/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65'0 for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. NIKJNG4 SupplyNef FM c&us NSF. 3 WRAS OLPCB' APPROVE LPCB Approved up to and including 2" " Approval pending. Reducer Coupling - Socket x Socket Physical Data n n 7M rrM Nominal Pipe Size Dimensions (mm / inch) Approx. Weight (lbs. / kgs.) Part Number inch metric A 1" x 3/4" DN25 x DN20 / 0.29 0.07 / 0.032 V5001 R-131 1'/4" x 1" DN32 x DN25 / 0.35 0.12 / 0.054 V5001 R-168 1'/2- x 3/4" DN40 x DN20 / 1.02 0.31 / 0.140 V5001 R-210 1'/2" x 1" DN40 x DN25 / 0.88 0.33 / 0.150 V5001 R-211 11/2" x 1'/4" DN40 x DN32 / 0.76 0.50 / 0.230 V5001 R-212 2" x 1" DN50 x DN25 / 0.97 0.44 / 0.200 V5001 R-249 2" x 1'/2" DN50 x DN40 / 0.46 0.50 / 0.230 V5001 R-251 CPVC Fittings Allowances for Friction Loss in Fittings Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90' Elbow 45' Elbow Coupling 3/4" DN20 1 / 0.3 3 / 0.9 7 / 2.1 1 / 0.3 1 / 0.3 1" DN25 1/0.3 5/1.5 7/2.1 1/0.3 1/0.3 11/4" DN32 1/0.3 6/1.8 8/2.4 2/0.6 1/0.3 1'/2" DN40 1/0.3 8 / 2.4 1 9 / 2.7 1 2/0.6 1 / 0.3 2" DN50 1/0.3 10/3.1 11 /3.4 2/0.6 1/0.3 2'/2- DN65 2/0.6 12 / 3.7 12 / 3.7 3 / 0.9 2/0.6 3" DN80 2/0.6 15 / 4.6 13 / 4.0 4 / 1.2 2/0.6 ■ ■ � IIIIIIIIIIIIIIIII� Worldwide Fire Protection www.vikinggroupinc.com Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturers datasheet. Specifications subject to change without notice. Socket x Groove Technical Features • Sizes Available (Nominal) : 1'/4" (DN32) through 3" (DN80) pipe diameters. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150OF (65"0 • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°O • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 1'/4" (DN32) and in Schedule 80 for sizes 1'/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. NIKJNG4 SupplyNef FM c&us NSF. 3 WRAS OLPCB' APPROVE LPCB Approved up to and including 2" " Approval pending. n n 7M rrM Coupling Adapter - Socket x Groove Physical Data Nominal Pipe Size K (in./mm) Dimensions (mm / inch) Approx. Weight (Ibs. / kgs.) Part Number inch metric B C 1'/4- DN32 1.66 / 42,2 / 0.83 / 1.04 / 2.98 0.17 / 0.077 V5001 G-012 1'/2" DN40 1.90 / 48,3 / 0.95 / 1.17 / 3.15 0.20 / 0.091 V5001 G-015 2" DN50 2.375 / 60,3 / 1.18 / 1.43 / 3.37 0.30 / 0.136 V5001 G-020 2'/2- DN65 2.875 / 73,0 / 1.43 / 1.74 / 3.66 0.52 / 0.236 V5001 G-025 3" DN80 3.50 / 88,9 / 3.50 -- - 0.72 / 0.327 V5001 G-030 CPVC Fittings Allowances for Friction Loss in Fittings Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4" DN20 1 /0.3 3/0.9 7/2.1 1 /0.3 1 /0.3 V, DN25 1 /0.3 5/ 1.5 7/2.1 1 /0.3 1 /0.3 1'/4" DN32 1 /0.3 6/ 1.8 8/2.4 2/0.6 1 /0.3 1'/2- DN40 1 / 0.3 8 / 2.4 9 / 2.7 2/0.6 1 / 0.3 2" DN50 1 /0.3 10/3.1 11 /3.4 2/0.6 1 /0.3 2'/2" DN65 2/0.6 12 / 3.7 12 / 3.7 3 / 0.9 2/0.6 3" DN80 2/0.6 15/4.6 13/4.0 4/1.2 2/0.6 Worldwide Fire Protection www.vikinggroupinc.com Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturers datasheet. Specifications subject to change without notice. Socket x NPT Thread Technical Features • Sizes Available (Nominal) : 3/4" (DN20) through 2" (DN50) pipe diameters. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65"0 • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Threaded Connections : 1 female threaded NPT outlet. Note : 4235-012BS & 4235-015BS female threaded BSP. • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 11/4" (DN32) and in Schedule 80 for sizes 1'/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150OF (6500 for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. NIKJNG* SupplyNef FM c&us NSF 3 N'RAS (LP)CB APPROVED Ear * LPCB Approved up to and including 2" ** Approval pending. n n 7M Female Adapter (Metal Thread Insert) - Socket x NPT Thread Physical Data Nominal Pipe Size Dimensions (mm / inch) Approx. Weight (Ibs. / kgs.) Part Number inch metric A 3/4" DN20 / 1.19 0.28 / 0.127 V5003BI-007 1" DN25 / 1.59 0.63 / 0.286 V5003BIBSP-010 1'/4" DN32 / 1.97 1.07 / 0.485 V5003BIBSP-012 1'/2- DN40 / 1.98 1.33 / 0.603 V5003BIBSP-015 2" DN50 / 1.99 2.00 / 0.907 V5003BIBSP-020 CPVC Fittings Allowances for Friction Loss in Fittings Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90' Elbow 45' Elbow Coupling 3/4" DN20 1 /0.3 3/0.9 7/2.1 1 /0.3 1 /0.3 1" DN25 1 /0.3 5/ 1.5 7/2.1 1 /0.3 1 /0.3 1'/4" DN32 1 /0.3 6/1.8 8/2.4 2/0.6 1 /0.3 1'/2" DN40 1 /0.3 8 / 2.4 9 / 2.7 2/0.6 1 /0.3 2" DN50 1 /0.3 10/3.1 11 /3.4 2/0.6 1 /0.3 2'/2" DN65 2/0.6 12/3.7 12/3.7 3/0.9 2/0.6 3" DN80 2/0.6 15/4.6 13/4.0 4/1.2 2/0.6 Worldwide Fire Protection www.vikinggroupinc.com Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer's datasheet. Specifications subject to change without notice. Spigot x NPT Thread Technical Features • Sizes Available (Nominal) : Female Adapter: 3/4" (DN20) and 1" (DN25) pipe diameters. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) at 150OF (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) • Threaded Connections : 1 female threaded NPT outlet. • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 11/4" (DN32) and in Schedule 80 for sizes 1'/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150OF (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. NIKJNG* SupplyNef FM c&us NSF WWRAS OLPCB' APPROVED a * LPCB Approved up to and including 2" ** Approval pending. n n 7M Female Adapter - (Metal Thread Insert) - Spigot x NPT Thread Physical Data Nominal Pipe Size Dimensions (mm / inch) Approx. Weight (lbs. / kgs.) Part Number inch metric A 3/4" DN20 / 2.00 0.28 / 0.127 V50032BI-007 1" DN25 / 2.72 0.61 / 0.277 V50032BI-010 CPVC Fittings Allowances for Friction Loss in Fittings Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45' Elbow Coupling 3/4" DN20 1 /0.3 3/0.9 7/2.1 1 /0.3 1 /0.3 1" DN25 1/0.3 5/1.5 7/2.1 1/0.3 1/0.3 1'/4" 1'/2" DN32 1 /0.3 6/ 1.8 8/2.4 2/0.6 1 /0.3 DN40 1 /0.3 8 / 2.4 9 / 2.7 2/0.6 1 /0.3 2" DN50 1 /0.3 10/3.1 11 /3.4 2/0.6 1 /0.3 2'/2" DN65 2/0.6 12/3.7 12/3.7 3/0.9 2/0.6 3" DN80 2/0.6 15 / 4.6 13 / 4.0 4 / 1.2 2/0.6 Worldwide Fire Protection wwwmikinggroupinc.com Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer's datasheet. Specifications subject to change without notice. Socket x NPT Thread Technical Features • Sizes Available (Nominal) : 3/4" (DN20) pipe run x'/2" (DN15) outlet, 1" (DN25) pipe run x'/2" (DN15) outlet and 1" (DN25) pipe run x 3/4" (DN20) outlet. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65"0 • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Threaded Connections : 1 female threaded NPT outlet. • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 11/4" (DN32) and in Schedule 80 for sizes 1'/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150OF (65'0 for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. NIKJNG* SupplyNef FM c&us NSF 3 N'RAS (LP)CB APPROVED Ear * LPCB Approved up to and including 2" ** Approval pending. n n Kle: 7M Sprinkler Head Adapter - Female (Metal Thread Insert) - Socket x NPT Thread Physical Data Nominal Pipe Size Dimensions (mm / inch) Approx. Weight (lbs. / kgs.) Part Number inch metric A 3/4' x'/2- DN20 x DN15 / 0.75 0.18 / 0.082 V5003SBI-101 1"x'/2" DN25 x DN15 / 0.76 0.21 / 0.095 V5003SBI-130 1" x 3/4' DN25 x DN20 / 0.95 0.18 / 0.082 V5003SBI-131 CPVC Fittings Allowances for Friction Loss in Fittings Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90* Elbow 45'Elbow�,111111111111111111116 Coupling 3/41, DN20 1 /0.3 3 / 0.9 7 / 2.1 1 /0.3 1 /0.3 1" DN25 1/0.3 5/1.5 7/2.1 1/0.3 1/0.3 11/4" DN32 1 /0.3 6/1.8 8/2.4 2/0.6 1 /0.3 11/2" DN40 1 /0.3 8 / 2.4 9 / 2.7 2/0.6 1 /0.3 2" DN50 1 /0.3 10/3.1 11 /3.4 2/0.6 1 /0.3 21/2" DN65 2/0.6 12 / 3.7 12 / 3.7 3 / 0.9 2/0.6 3" DN80 2/0.6 15/4.6 13/4.0 4/1.2 2/0.6 Worldwide Fire Protection www.vikinggroupinc.com Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer's datasheet. Specifications subject to change without notice. Spigot x NPT Thread Technical Features • Sizes Available (Nominal) : 3/4' (DN20) and 1" (DN25) pipe run, '/2' ON15) outlet. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65'0 • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Threaded Connections : 1 female threaded NPT outlet. • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4' (DN20) through 1'/4' (DN32) and in Schedule 80 for sizes 11/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65°0 for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. NIKJNG4 SupplyNef FM c&us NSF. 3 WRAS OLPCB' APPROVE LPCB Approved up to and including 2" " Approval pending. n n 7M P'h P'h (M Sprinkler Head Adapter - (Metal Thread Insert) - Spigot x NPT Thread Physical Data Nominal Pipe Size Dimensions (mm / inch) Approx. Weight (Ibs. / kgs.) Part Number inch metric jo it 3/4" x'/z' DN20 x DN15 / 1.50 0.19 / 0.086 V50032SBI-101 V x'h" DN25 x DN15 / 1.85 0.18 / 0.082 V50032SBI-130 CPVC Fittings Allowances for Friction Loss in Fittings Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4" DN20 1 /0.3 3 / 0.9 7 / 2.1 1 /0.3 1 /0.3 V, DN25 1 /0.3 5/ 1.5 7/2.1 1 /0.3 1 /0.3 1'/4" DN32 1 /0.3 6/ 1.8 8/2.4 2/0.6 1 /0.3 1'/2' DN40 1 /0.3 8/2.4 9/2.7 2/0.6 1 /0.3 2" DN50 1 /0.3 10 / 3.1 11 / 3.4 2/0.6 1 /0.3 21/2" DN65 2/0.6 12 / 3.7 12 / 3.7 3 / 0.9 2/0.6 3" DN80 2/0.6 15/4.6 13/4.0 4/1.2 2/0.6 up Worldwide Fire Protection www.vikinggroupinc.com Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturers datasheet. Specifications subject to change without notice. Spigot x Socket Technical Features • Sizes Available (Nominal) : 1" (DN25) through 3" (DN80) inlet, 3/4" (DN20) through 2'/2" (DN65) outlet. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65'0 • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 1'/4" (DN32) and in Schedule 80 for sizes 1'/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150°F (65'0 for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. NIKJNG4 SupplyNef L FM c&us NSF. 3 WRAS OLPCB' APPROVE LPCB Approved up to and including 2" " Approval pending. n n 7M rrM Reducer Bushing - Spigot x Socket Physical Data Nominal Pipe Size Dimensions (mm / inch) Approx. Weight (lbs. / kgs.) Part Number inch metric L N 1" x'/4" DN25 x DN20 / 1.28 / 0.27 0.05 / 0.023 V5018-131 11/4" x'/4" DN32 x DN20 / 1.41 / 0.27 0.05 / 0.023 V5018-167 1'/4" x 1" DN32 x DN25 / 1.41 / 0.40 0.06 / 0.027 V5018-168 11/2" X 3/4" DN40 x DN20 / 1.53 / 0.27 0.08 / 0.036 V5018-210 1'/2" x 1" DN40 x DN25 / 1.53 / 0.40 0.09 / 0.041 V5018-211 1'/2" x 11/4" DN40 x DN32 / 1.53 / 0.40 0.10 / 0.045 V5018-212 2" x'/4" DN50 x DN20 / 1.66 / 0.65 0.20 / 0.091 V5018-248 2" x 1" DN50 x DN25 / 1.66 / 0.27 0.22 / 0.100 V5018-249 2" x 1'/4" DN50 x DN32 / 1.66 / 0.40 0.24 / 0.109 V5018-250 2" x 1'/2" DN50 x DN40 / 1.66 / 0.52 0.25 / 0.113 V5018-251 2'/2" x 11/4" DN65 x DN32 / 1.94 / 0.55 0.27 / 0.122 V5018-290 2'/2" x 11/2" DN65 x DN40 / 1.94 / 0.68 0.31 / 0.141 V5018-291 2'/2" x 2" DN65 x DN50 / 1.94 / 0.80 0.31 / 0.141 V5018-292 3" x 2" DN80 x DN50 / 2A2 / 0.64 0.48 / 0.218 V5018-338 3" x 2'/2" DN80 x DN65 / 2.42 / 0.91 0.64 / 0.290 V5018-339 Refer to the "CPVC Equal Tee" datapage or manufacturers installation instructions for friction loss information. W E Worldwide Fire Protection r www.vikinggroupinc.com Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturers datasheet. Specifications subject to change without notice. Socket Technical Features • Sizes Available (Nominal) : 3/4" (DN20) through 3" (DN80) pipe diameters. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 1'/4" (DN32) and in Schedule 80 for sizes 1'/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150OF (65'0 for sprinkler NIKJNG* SupplyNef FM c �L us NSF 3 N'RAS (LP)CB APPROVED Ear service. * LPCB Approved up to and including 2" Approved for National Sanitation Foundation (NSF) potable • Approval pending. water services and complies with WRAS requirements for cold water use. n n 7M Cap -Socket Physical Data Nominal Pipe Size Dimensions (mm / inc Approx. Weight Ubs. / kgs.) Part Number inch metric '/4' DN20 / 0.31 0.08 / 0.036 V5017-007 1" DN25 / 0.38 0.14 / 0.064 V5017-010 1'/4" DN32 / 0.40 0.20 / 0.091 V5017-012 1'/2" DN40 / 0.41 0.26 / 0.118 V5017-015 2" DN50 / 0.42 0.38 / 0.172 V5017-020 2'/2" DN65 / 0.57 0.57 / 0.259 V5017-025 3" DN80 / 1.26 0.87 / 0.395 V5017-030 Worldwide Fire Protection www.vikinggroupinc.com Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer's datasheet. Specifications subject to change without notice. NPT Thread Technical Features • Sizes Available (Nominal) :'/2" (DN15) pipe diameter. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65°C) • Pressure Data : For pressure testing only • Threaded Connections : Threaded NPT • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 1'/4" (DN32) and in Schedule 80 for sizes 1'/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. This product is FM Approved for pressure testing only. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. NIKJNG* SupplyNef FM S (LP)CB APPROVED Ear * LPCB Approved up to and including 2" ** Approval pending. n n 7M Test Plug - Thread Physical Data Nominal Pipe Size Dimensions (mm / inch) Approx. Weight Obs. / kgs.) Part Number inch metric A '/2" DN15 / 1.06 0.03 / 0.014 V450-005 Worldwide Fire Protection www.vikinggroupinc.com Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturer's datasheet. Specifications subject to change without notice. Socket x Socket Technical Features • Sizes Available (Nominal) : 3/4" (DN20) through 2" (DN50) pipe diameters. • Environmental Specifications : Indoor use only. Maximum Ambient Temperature : 150°F (65"0 • Pressure Data : Working Pressure : 175 PSI (12.1 bar) at 150°F (65°C) • Specifications : For use with listed CPVC fire sprinkler pipe produced in Standard Dimension Ratio (SDR) 13.5, as specified in ASTM F442. CPVC Fire Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" (DN20) through 1'/4" (DN32) and in Schedule 80 for sizes 1'/2" (DN40) through 3" (DN80), in accordance with ASTM F437 (Schedule 80 Threaded Fittings), ASTM F438 (Socket type Schedule 40) and ASTM F439 (Schedule 80 Fittings), as applicable. These products are UL Listed and FM Approved for a rated working pressure of 175 psi (12.1 bar) at 150OF (65°C) for sprinkler service. Approved for National Sanitation Foundation (NSF) potable water services and complies with WRAS requirements for cold water use. NIKJNG4 SupplyNef FM c&s NSF. 3 WRAS OLPCB' APPROVE LPCB Approved up to and including 2" " Approval pending. n n 7M rrM Union - Socket x Socket Physical Data Nominal Pipe Size Dimensions (mm / inch) Approx. Weight (Ibs. / kgs.) Part Number inch metric A L 3/4' DN20 / 2.46 / 0.43 0.27 / 0.122 V5033E-007 1" DN25 / 2.70 / 0.43 0.40 / 0.181 V5033E-010 1'/4" DN32 / 3.31 / 0.79 0.87 / 0.395 V5033E-012 1'/2" DN40 / 3.58 / 0.80 0.93 / 0.422 V5033E-015 2" DN50 / 3.82 / 0.80 1.83 / 0.830 V5033E-020 2'/2" DN65 / 4.74 / 0.93 3.47 / 1.574 V5033E-025 3" DN80 / 5.05 / 1.42 3.95 / 1.792 V5033E-030 CPVC Fittings Allowances for Friction Loss in Fittings Nominal Pipe Size Equivalent Feet / Meters of Pipe inch metric Tee Run Tee Branch 90° Elbow 45° Elbow Coupling 3/4' DN20 1 /0.3 3 / 0.9 7 / 2.1 1 /0.3 1 /0.3 1" DN25 1/0.3 5/1.5 7/2.1 1/0.3 1/0.3 1'/4' DN32 1 /0.3 6 / 1.8 8 / 2.4 2/0.6 1 /0.3 1'/2" DN40 1 /0.3 8 / 2.4 9 / 2.7 2/0.6 1 /0.3 2" DN50 1 /0.3 10/3.1 11 /3.4 2/0.6 1 /0.3 2'/2" DN65 2/0.6 12 / 3.7 12 / 3.7 3 / 0.9 2/0.6 3" DN80 2/0.6 15/4.6 13/4.0 4/1.2 2/0.6 wr Worldwide Fire Protection www.vikinggroupinc.com Manufactured for Viking SupplyNet by Nibco Incorporated. Refer to Manufacturers datasheet. Specifications subject to change without notice. CAL FIRE - RIVERSIDE UNIT RIVERSIDE COUNTY FIRE DEPARTMENT OFFICE OF THE FIRE MARSHAL — LA QUINTA CALIFORNIA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org August 28, 2022 OnGuard Fire Protection 6438 Arville Street Las Vegas, NV 89118 Re: Residential Fire Sprinkler Plan Review — THE CENTRE — SOLTERRA — TR 37359 FCMP2022-0024 / MASTER PLAN 4 — PRODUCT 2 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Contractor shall separately apply and pay fees for the various Production Home lots associated with this project as each will be handled under separate permit. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist