Loading...
FCMP2022-0028 Palo Verde Plan 2a u�tt Project Details PROJECT NUMBER ` =�w City of La Qu i nta FCM P2022-0028 MoFT�• . Description: PALO VERDE / MASTER PLAN 2 / TRACT# 32279 & 33336 Status: APPROVED Type: FIRE CONSTRUCTION MASTER PLAN (WEB) Status Date: Subtype: FIRE SPRINKLER MASTER PLAN Applied: 9/15/2022 Address: 80550 AVENUE 58 Approved: 10/20/2022 City, State, Zip: LA QUINTA,CA92253 Closed: Project Manager: Expired: Details: ADDITIONAL SITES CHRONOL DAYS REVIEWS ACTIONS INSPECTIONS CONDITIONS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST STE 200 CORONA CA 92879 (951)272-2522 jamieb@fireinc.net CONTRACTOR FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST STE 200 CORONA CA 92879 (951)272-2522 jamieb@fireinc.net OWNER Williams Homes 24911 Stanford Avenue Santa Clarita CA 91355 (951)272-2522 jamieb@fireinc.net DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY EXHIBITS AND TRADE SHOWS 101-0000-42421 0 $175.00 $0.00 Printed: Friday, April 21, 2023 1:06:27 PM 1 of 3 CENTRALSOLIARE a u�tt Project Details PROJECT NUMBER ` =�w City of La Qu i nta FCM P2022-0028 MoFT�• CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY EXHIBITS AND TRADE 101-0000-42420 0 $87.00 $0.00 SHOWS PC Total Paid for FIRE FEES: $262.00 $0.00 RECORDS MANAGEMENT FEE - 101-0000-42416 0 $21.00 $0.00 MAJOR Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $0.00 TECHNOLOGY 502-0000-43611 0 $5.00 $0.00 ENHANCEMENT FEE Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $0.00 INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES DATE DATE RETURNED REVIEW TYPE REVIEWER SENT DATE DUE DATE STATUS REMARKS NOTES DATE 1ST FIRE (2WK) KOHL 9/15/2022 9/29/2022 10/20/2022 APPROVED SEE ATTACHMENTS HETRICK 1ST PERMIT AARON 9/15/2022 9/16/2022 9/16/2022 COMPLETE TECHNICIAN (1DAY) HICKSON :•RR •• •my Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 9/15/2022 Etrakit Contractor 1ST SUBMITTAL Fire Plan Plan Type 2 Fire Plan.pdf 1 Printed: Friday, April 21, 2023 1:06:27 PM 2 of 3 CENTRALSOLIARE a u�tt Project Details PROJECT NUMBER ` =�w City of La Qu i nta FCM P2022-0028 MoFT�• r Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 9/15/2022 Etrakit Contractor 1ST SUBMITTAL Plan Type 2 Hydraulic 1 Hydraulic Calculations Calculations.pdf DOC 9/15/2022 Etrakit Contractor 1ST SUBMITTAL Fire Fire Flow.pdf 1 Flow DOC 4/17/2023 Etrakit Contractor Application Plan 2 Application.pdf 1 DOC 4/17/2023 Etrakit Contractor Tracking Sheet Plan 2 Building Permit 1 and Tracking Sheet.pdf DOC 4/17/2023 Etrakit Contractor Revised Calcs Plan 2 Calcs.pdf 1 DOC 4/17/2023 Etrakit Contractor Revised Fire Plan Plan 2 D1.pdf 1 FCMP2022-0028 - FCMP2022-0028 - DOC 10/20/2022 KOHL HETRICK APPROVED PLANS AND APPROVED PLANS AND 1 CALCS.pdf CALCS.pdf DOC 10/20/2022 KOHL HETRICK FCMP2022-0028 - COA FCMP2022-0028 - COA 1 LETTER.pdf LETTER.pdf Printed: Friday, April 21, 2023 1:06:27 PM 3 of 3 CENTRALSOLIARE VI■/�- �/<M< CONCEAL PEENTWL ,�(V.,A<^,•. CRINKLE VPENDENT SPRINKLER VK494 (IG.a) mOmtlOn. H 0 N In4�nblFl PM Ddee, NasDlnOe MI N05B 1klepnow: AY N59501 F. Txnnesroru.l.ue,.aarvlm:enau6aM Fa.: 38&et&tew Fmsll:Isnerw9!.Ikln m.wm xwm. B en nml.,emme.l e. wnwaw.wanpvmvgwsam v ernes spate' ez�o DDa epuiwei�i�e Eiei �i a9F�iFa��n ,.9� �.a ueu �o- �re.wnue�eusiaM ex we.wwle ru�µwf. LROINGUSANDAPPROIALS L "Y-xatu--apmwu .F sNpwlwuwmlmwwa�u umM P. renex0 a ,F ,,.wzv xP: nz pppp weame FPuaaOax�nRwaMWW VIMn9 VK484.4.8 KFaebr ftpitlantW CDnwaI9d PNNNIRW 8Pl1akbr Brn� W a�w PMwn ARM—� aweim wxL msAq:mTlMgam+ww De�M TYoe IwxM .�..� hll D.izan rwa PAy 7 M>x�T Ray PM Kan row .F wMw.xw a'w ros':'e'm a�n w.+xem.+p os.n cps _ a�.�rlwe Twew ae• Iaxp.liwj• ORMN oMerp wlwq ta0'n Oe •cp pyq , Meq — I I I ePk+IwFkwacmewe�aeR � coma, erymwev.Anpw Deee, emuas meee, ewnee uTw. PaeMO VIA/�� /�•jjjjjjjjjff PEEDEN RE9INKI-ER SPRINKLER VKCIa (K4.9) 0 aaeveegnklepummm 1. DE9CR—ON re gee W iMea� meaerwnava- Z mN. DN.AP e ue•mwma ® vm Aw'm�a: uepeaBBE. vow•wE ue AppmvlD Fwm _ tAtom nwtit pppp McPw..axmm moewveewwav]suDl VIkInB VKI99, d.9 KFaeMlESMat PanOant BPNMIar a11paIIIIU!•aEL66a ®mmM mmmM MMMM 13D/CRC 313.3 GENERAL NOTES t FI O N THE MERCER. LAL,.G l _FLECOLSE lL PA1ER ANENTLYADIIET) SO EH FERN No NyNGH PIPE DNM CTUIAL THE THE ANLPACTLGC FECLIFENENTC Ann THOCE CONTAINED IN 11 ANO Mnurev�EApvlarvLETc.IrvsrALLEO AT s r. MAMUM SPANE DING (SEEPENDENT to LI ETECNI A7NU1FACTUHEOSY VIMNG INITALLEDAT I6 R. Malt SPACING HYDRAULIC SYSTEM This BuiNing is Pmlapled by a Hydrzulically Designed AutomaSc SpnnNer System. Date Installed 8'14122 Location CALC MEAL Numberof SprrMem 2 BISK or Deemn oExslrr .05 gPSNgR 20EaIfl1E0A FAOF 016CHRROF 512�.fl. System Demand 1.w IrIOw RATE 3ij EPT, 2.RESINAL PRESSUREATTHE RASE OF THE RISER 34.1 psi Installed By Fl.8pnnk1MS kmslnckms,lnc. 9p HYDRAULIC NAMEPLATE UNDERGROUND DETAIL N.T.S. N.T.S. (FOR REFERENCE ONLY) PALOVERDIE TRS. PLAN 2 IAOUINTA, CA. AHJ. CRY OF IA MINTA FIRE DEPARTMENT LEGAL DESCRIPTION OCCUPANCY 13IU CONSTRUCTION'. VFB STORIES BUILGING AREA: 3,- SOFT. FIRE SPRINKLER SYSTEM' DES IGNEDAND INSTALLED PER 2016 NFPA MD ALL RESIDENTIAL WTH AM DENSITY NATHIN AREAS, BUILDING SUMMARY • CONCEALED REEL PENDENT SPRINKLER Q CONCEALED RES. PENDENT SPRINKLER O CHANGE IN ELEVATION ® RISER LO[ATUN(PER DETAIL) ® NODE POINT FOR CALWtATION HANGER TC DETAL Riverside County Fire Department La Quinta Office of the Fire Marshal By: Kohl Hetrick `.„;.:; 10202022 3:4507 PM The approval of PRIDE Intl specification, does not permit the violation, deledon, omiaaion or faulty irEtallaticn of any re9uire-- of Title 24 or any Local Ordinances. Construction shall remain eaible antl exp,wd for inspection puDposea until approved by the Fire Department. PERMIT # - FCNW2022-0028 APPROVAL STAMP SYMBOLLEGEND 0 Z W CD W J 0 z Q U) LU I- 0 Z cr W z U-1 JOB NO: 322M DATE: 9114M .— BY: AD. N884810 O RISER DETAIL N.T.S. LICENSE NO. 684600 705 E. HARRISON ST., SUITE 200 CORONA, CA 92879 PH - 800-915-3473 FAX - 951-272-2535 CUSTOM, TRACT, MULTI-FAMILY AND COMMERCIAL DESIGN, ENGINEERING AND INSTALLATION 1/4" = 1' IF SHEET IS LESS THAN SIZE - 24" X 36" SHEET ID 24" X 36" IT IS A REDUCED SCALE PRINT SCALE REDUCE ACCORDINGLY CLASSIFICATION C-16 LICENSE NO. 684600FIREPROTECTIONCO N T R ACTORFST A TE OF C A L IF O RNIAThe recipient of these plans hereby acknowledges that all plans, details, specifications or methods of installation contained in this set of plans is the sole property of Fire Sprinkler Systems, Inc. and that any use of this set of plans is prohibited and is a violation of copyright laws without first receiving permission from Fire Sprinkler Systems. PLAN 2 FIRE SPRINKLER PLAN SHEET FP2 OF FP3 DESIGN AND INSTALLATION SHALL CONFORM TO NFPA 13D, 2016 ED. NOTES: 1.ALL HEAD SPACING TO BE 16'x16', UNLESS OTHERWISE NOTED. 2.ALL PIPES TO BE ¾" CPVC, UNLESS OTHERWISE NOTED. 3.PIPE CLEARANCES MUST BE IN ACCORDANCE WITH NFPA 13-9.3.4. 4.HANGERS SHOWN FOR REFERENCE PURPOSES ONLY. HANGER SPACING TO BE PER TABLES ON THIS SHEET. 5.ALL PIPING INSTALLED WITHIN THE ATTIC SHALL BE PROVIDED WITH MIN. 6" INSULATION ON THE ATTIC SIDE OF THE PIPING TO AVOID EXPOSURE OF THE PIPING TO TEMPERATURES IN EXCESS OF THE PIPES RATED TEMPERATURE (2016 NFPA 13D 7.7). 6.SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55sqft. AND LESS. (SECTION 8.3.2.) 7.SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THAT MEET ALL OF THE FOLLOWING REQUIREMENTS: (1) THE AREA OF THE SPACE DOES NOT EXCEED 24sqft. (2) THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIALS AS DEFINED IN NFPA 220. 8. 8.2.5.1.2 THE DISTANCE SHALL BE MEASURED FROM THE CENTER OF THE SPRINKLER TO THE CENTER OF THE OBSTRUCTION. 9. 8.2.5.6 SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS THE CUMULATIVE DRY AREA DO NOT EXCEED 15sqft (1.4 sqm) PER SPRINKLER. TOTAL LIVING AREA - GARAGE AREA- 3,213 SQFT. 653 SQFT.NO.DATEREVISION12345Size Range:3 4" through 3" Finish: Pre-Galvanized Carbon Steel per ASTM A653 Service: Hanger for CPVC, steel, & copper pipe in the horizontal position on the bottom and side of structural wood beams, composite beams and Steel 20 Ga. (min.) (Fig. A, C respectively). Can be used as a restrainer when installed on top of structural wood beams (Fig. B), for limiting pipe movement due to thrust loads during sprinkler system start-up. It can also be used as a guide to limit movement for pipe in the vertical position. When used on composite wood beams, web thickness must be 3 8" or greater. Approvals: cULus Listed Installation: • Snap hanger over pipe. • Secure hanger to mounting surface with screws provided. • Do not make adjustments to hanger mounting flanges that result in clamping the pipe to the mounting surface. Pipe must be allowed to move freely through hanger. • Steel applications require two (2) #14 x 1" hex washer head self-drilling TEK screws. Not Supplied. Part Number STD-0090. Features: • Beveled edge design helps protect the CPVC pipe from any rough surface. • Easily attaches to wood structure with #10 x 1" hex washer head self threading screw supplied with product. • Retaining dimples hold the strap onto the pipe for ease of installation. (Not shown) Ordering: Specify pipe size, figure number, and description. Fig. A Fig. B Pipe Size 1 2 3 A 1 11⁄4 B Fig. C FIG. 186: DIMENSIONS (IN) • WEIGHT (LBS) øC E 1⁄4 F Approx. Weight/100 (lbs) 5 6 7 8 9 14 17 3 4 11 4 11 2 21 2 15 16 19 16 113 16 21 4 25 8 213 16 31 4 33 8 37 8 45 16 53 8 65 16 11 8 13 16 118 1½ 11116 218 29 16 27 8 312 No pre-drilling required. NOT TO SCALE ANVIL 186 HANGER (STEEL - COPPER - C.P.V.C.) Size Range:3 4" through 2" Material: Carbon Steel Finish: Pre-Galvanized per ASTM A653 Service: • Hanger and surge restraint for horizontal CPVC, steel, and copper piping when installed on the top, bottom, and side of the supporting structure. • Guide for vertical CPVC, steel, and copper piping when installed on the side of the supporting structure. • Horizontal and vertical seismic restraint per NFPA 13-2016 requirements. • May be installed with concrete, steel structural members, and other structural members with fasteners which comply with the requirements of NFPA 13. Approvals: cULus Listed Patents: No. 6,648,278 Installation: • Snap hanger over pipe. If needed, squeeze strap back around pipe. • CPVC pipe must be allowed to slide freely through the Fig. 188R. • Secure hanger to mounting surface with screws provided or with listed fasteners. Features: • Beveled edge design helps protect the CPVC pipe from any rough surface and eliminates pipe abrasion. • Easily attaches to wood structure with #10 x 1" hex washer head self-threading screw supplied with product. No pre-drilling required. • Bottom of pipe is offset 112" from the structure. Eliminates wooden spacer blocks. Ordering: Specify CPVC pipe size, figure number and description. Hanger & Restrainer Installation - Backing Nut Hanger = 1 - at top fastener Restraint = 2 - on each fastener Hanger & Restrainer Guide & Restrainer Per NFPA-13D and NFPA-13R B A E øC F D G Hanger and Restrainer FIG. 188R: DIMENSIONS (IN) • WEIGHT (LBS) CPVC Pipe Size 3 4 1 114 112 2 A 23 4 35 8 B 312 312 314 414 43 8 øC ¼ ¼ ¼ ¼ ¼ D 2 E 1 1 1 1 1 F 25 8 314 312 4 FIG. 188R: LISTED FASTENERS Pipe CPVC Steel & Copper Wood and Composite Beams Screw Supplied or #10 x 1" TEK Screw #14 x 1" TEK Screw or 14"x112" Lag Screw Steel (18ga. Minimum) #14 x 1" TEK Screw or 14"x1" TEK Screw #14 x 1" TEK Screw or 14"x1" TEK Screw G 112 Max. Hanger Spacing (FT.) 512 6 612 7 8 Approx. Weight/100 (lbs) 11 12 13 14 16 21316 21316 31116 23 16 2516 2716 21116 35 8 112 112 112 112 NOT TO SCALE ANVIL 188R HANGER (STEEL - COPPER - C.P.V.C.) SPACINGTEMP.K-FAC.SYMBOLMODELMANUF.SIN #ORIFICE256QUANTITY-TOTAL SPRINKLERS IN THIS SHEET:31--------VIKINGVIKING4.94.9200°175°16'x16'16'x16'VK494VK468VK468PENDENT7/16"7/16"VK494CONC. PEND.---------½" Keyless Hose Bib 90 Deg. Elbow w/ ½" brass thread insert 90 Deg. Elbow C B A B A *DETAIL NOT TO SCALE From First or Second Floor Whichever is Most Remote REMOTE INSPECTOR'S TEST N.T.S. Inspector's Test Sign C HB J J SA SA/COD VP J SA/COD SA J SA SA SA/COD J J HB/SOVJJJSCALE: 1/4" = 1'-0" PLAN 2 - FIRE SPRINKLER FLOOR PLAN HEAT ZONE F.A.U. ATTIC ACCESS BATH 3 10'-0" CLG. 43 SQFT. POWDER 10'-0" CLG. 32 SQFT. BATH 2 10'-0" CLG. 45 SQFT. GARAGE 10'-0" CLG. KITCHEN 10'-0" CLG. OUTDOOR ROOM 10'-0" CLG. DINING ROOM 10'-0" CLG. PANTRY 10'-0" CLG. PRIMARY BEDROOM 10'-0" CLG. PRIMARY BATH 10'-0" CLG. 26 SQFT. W.I.C. 10'-0" CLG. COVERED ENTRY 10'-0" CLG. LAUNDRY 10'-0" CLG. FOYER 10'-0" CLG. 12 SQFT. 11 SQFT. BEDROOM 2 10'-0" CLG. FLEX ROOM 10'-0" CLG. 17 SQFT. BEDROOM 3 10'-0" CLG. DINING ROOM 10'-0" CLG. HALL 10'-0" CLG. 20'X20' SPACING 20'X20' SPACING 20'X20' SPACING 20'X20' SPACING 20'X20' SPACING 20'X20' SPACING 20'X20' SPACING 20'X20' SPACING RISER LOCATION 10 5'-1"8'5'-1"11'-6"2'-7"11'-5"8"9'-3"13'-1"9'-3"1'-7"8"3'-9"8'-3"5'-1"2'-4"4'-11"8'-3"3'-6"2'-10"2'-4"6'-2"9'-4"3'-11"2'-4"8'-9"2'-7"5'-9"11"12'-1"3'-6"11'-5" 2'-7"7'-1"4'-5"1'-10"8'-8"1'7'3'2'-3"1'-5"11'-1"2'-7"14'-8"3'-10"1'-6"8'-6"5'-6"15'-2"8'3'-4"2'-8"8'2'-8"7'-7"15'-6"2'-8"2'-6"7'-7"2'-6"5'-3" 8'4'-6"7'-11"5'-10"4'-4" 10'10'8'-4"4'-7"8'15'-6"6'5'-1"10'-3"9'-6"8'-6"4'-3"1'-10"4'-4"1'-9"7'-2"5'-3"5'-6"2'-11" 5'3'-2"14'-8"14'9'-11" 6'-2"7'-5"13'-1"10'7'-2"2'5'-11"3' 3'6'-8"3'-8"3'-10"8'-4"9'-11"9'-7"6'-11"5'-4"7'-6"5'-11"3' 10' 11 14 15 171612 13 18 CALC AREA 1 CALC AREA 2 DRAWN BY: 32292 9/14/22 JOB NO: DATE: A.D.WILLIAMS HOMESPALO VERDEBY:LA QUINTA, CAPLAN 2 LICENSE NO. 684600 705 E. HARRISON ST., SUITE 200 CORONA, CA 92879 PH - 800-915-3473 FAX - 951-272-2535 CUSTOM, TRACT, MULTI-FAMILY AND COMMERCIAL DESIGN, ENGINEERING AND INSTALLATION AS SHOWN IF SHEET IS LESS THAN SIZE - 24" X 36" SHEET ID 24" X 36" IT IS A REDUCED SCALE PRINT SCALE REDUCE ACCORDINGLY CLASSIFICATION C-16 LICENSE NO. 684600FIREPROTECTIONCO N T R ACTORFST A TE OF C A L IF O RNIAThe recipient of these plans hereby acknowledges that all plans, details, specifications or methods of installation contained in this set of plans is the sole property of Fire Sprinkler Systems, Inc. and that any use of this set of plans is prohibited and is a violation of copyright laws without first receiving permission from Fire Sprinkler Systems.SECTIONS FOR REFERENCE ONLYPLAN 2 SECTIONS SHEET FP3 OF FP3NO.DATEREVISION12345DRAWN BY: 32292 9/14/22 JOB NO: DATE: A.D.WILLIAMS HOMESPALO VERDEBY:LA QUINTA, CAPLAN 2 �JJAlre �ISTRi 0 Domestic Water System Flow Analysis Coachella Valley Water District 75515 Hovley Lane East Palm Desert, CA 92211 Domestic Water System Flow Analysis (Hydraulic Model) GEO 06-07-21-4 PZ 22-13337 Requested By: Williams Homes, Inc. Date: 3-02-2022 Address: 24-911 Avenue Stanford Santa Clarita, Ca 91355 APN: 762-480-016 Req. Fire Flow: gpm at 20psi for hours. Contact Name: Autumn Gasparella Project Name: Palo Verdes, La Quinta Phone: 323-351-8296 Email: AGasparella@williamshomes.com Cell: 323-351-8296 Domestic Water System Flow Analysis Location: Fire Hydrant within Tr. No. 32279 near lot 16 Rosewood Ct. La Quinta y Flow Analysis Description Model Information CVWD • -ModeRequested Test 1 Test 2 Test 3 Test 4 Flow Domestic Elevation (Ft): -36 None system flow available without exceeding Steady State, Dynamic (psi): 88.6 Residual Pressure (psi): 86.1 Fire Flow Tested (gpm): 750 N/A CVWD's Combined Total: N/A criteria. Tested Model Junction: 122764 Duration: 2 hours Demand Conditions: Peak Day Demand (PDD) Reservoir No./Level (s): Reservoir 6726/21.9' Pumps Operating No's: Pumps On Pressure Zone and HGL: Lake Cahuilla (145') Model: CVWD DOMESTICWATER_2020UPDATE_092221 Comments: The domestic water system is capable of providing 750 gpm for 2 hours that satisfies CVWD's minimum pressure, velocity, and/or head loss criteria. This simulated system flow analysis may not include all facilities that may be required for this development/project. Please check with Development Services for further information on all required facilities. The theoretical flow to drop the residual pressure to 20 psi is 4,600 pm. Please note the theoretical flow exceeds CVWD's design criteria on the domestic water network. These results are based on hydraulic modelling and not a guarantee that CVWD's domestic water system will have the capacity to supply water to the project at the flows or pressures indicated. It is important to note that the capacity of the on -site fire system, meters, service lines, backflow assemblies and other appurtenances were not considered in this analysis, which may alter actual flows or pressures. Due to continuous changes in the system, CVWD only considers this system flow analysis valid for six months from date of modelling/analysis. These system flow analysis comments are for plan check purposes only. The ultimate design responsibility resides with the Engineer -of -Record for this Project. Should you have any questions or need additional information, please contact me at (760) 398-2661, ext. 2397. Completed By: Date: 3�— Page 1 of 1 ENG DS-016 r 7Eq(8/31/15) _.t 656992 ' 657034 57-625 57-630 �D N N 17 5 656994 657032 57-655 57-660 U7 \0 11• N 18 6 TRACT 656996 657030 57-685 57-690 q 19 7 32279 01 TRACT 3336 656998 ou 657028 co 57-715 O 57-720 N 20 8 304 287 m (1J nJ 21 9 305 286 o a cu 22 10 657004 a zo 285 57-805 0 N 23 11 Hydrant to 657006 284 N 57-635 7• � 12 be tested 657008 283 57-865 m (Y) CL 657010 282 57-895 655426 c IRR N m 657012 281CD — 65704 In 57-925 N IRR (34280) 21 LP.-07 m N M a AVENUE 57-617 J J' ....� (U 656764 656742 ~ 57-628 (U (U 57-643 11, (U 656766 656740 57-654 M 57-669 0J 656768 656738 57-680 V 0 57-695 N 656770 656736 57-706 Ul 57-721 o N m � a 656772 656734 a 57-732 57-747 (L 0] 656774 656732 5-758 I� 57-773 R.7 Q n LOT H 806560 57-829 LOT G 656730 656776 57-825 57-810 a `L TRACT 30487 656728 N 656778 57-851 57-836 Q' R 656780 656726 57-877 57-862 c r Q F- 656724 Z 656782 57-903 < 57-888 - r 656784 656722 57-929 57-914 R OJ 11• r 656788 656720 57-955 v 57-940 (* of r d 656796 ca 57-940 ODEOT E FIRE SPRINKLER SYSTEMS 705 E HARRISON ST, #200 CORONA, CA 92879 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR PALO VERDE LA QUINTA, CA PLAN 2 10% TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN CALC AREA 1 Date: 9/14/2022 File No: 32292 Data File Name: Plan 2.rdf SPRINKLER SPACING 256.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 16.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 8.0 ft. SPRINKLER SPECIFICATIONS Mfr: Viking Descr: VK494 Conc.Pend.(16xl6) K=4.90 Calculated K Factor for Arm-Overs & Drops: 1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee) 0.0 ft. x 0.874 in. Arm -Over: K=4.67 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC HWC: 150 WATER SUPPLY Source: Public Test Date: 3/2/22 By: CVWD Static: 79.7 psi Resid: 77.5 psi Flow: 750.0 gpm Public Main Size: 8 in Domestic Demand: 5.0 gpm at node number 5 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press. Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 13.0 7.6 17 18.0 79.7 31.6 2 13.0 7.6 17 31.1 79.7 53.5 REVIEWING AUTHORITY CITY OF LA QUINTA FIRE DEPARTMENT RESULTS OF ANALYSIS PIPE & NODE DATA * FLOW ANALYSIS * 1 sprinkler flowing * 2 sprinklers flowing FIXD P # END LEN FIT. LOSS EL SP *DISCH FLOW PF PT *DISCH FLOW PF PT HWC NOD DIA EQV.LN PUMP (FT) (K) *(GPM) FL/FT PE (PSI)*(GPM) FL/FT PE (PSI) ------------------------------------ --------------------- --------------------- 1 1 70.00 EL2BG ---- -2.0 SRCE ---- 18.0 1.21 31.6 ---- 31.1 3.34 53.5 150 2 1.481 22.0 ---- -2.0 ---- ---- 0.01 0.00 30.4 ---- 0.04 0.00 50.2 2 2 1.00 -4.0 -2.0 ---- ---- 18.0 0.09 30.4 ---- 31.1 0.25 50.2 150 3 0.995 0.0 ---- -2.0 ---- ---- 0.09 0.00 26.3 ---- 0.25 0.00 45.9 3 3 150.00 3L ---- -2.0 ---- ---- 18.0 3.48 26.3 ---- 31.1 9.60 45.9 150 4 1.360 24.0 ---- -2.0 ---- ---- 0.02 0.00 22.9 ---- 0.06 0.00 36.3 4 4 4.00 L ---- -2.0 ---- ---- 18.0 0.20 22.9 ---- 31.1 0.55 36.3 150 5 1.265 3.0 ---- 2.0 -5 5 0.03 1.73 20.9 5 0.08 1.73 34.1 5 5 2.00 R ---- 2.0 -5 5 13.0 0.09 20.9 5 26.1 0.33 34.1 150 6 1.101 1.0 ---- 4.0 ---- ---- 0.03 0.87 20.0 ---- 0.11 0.87 32.9 6 6 1.00 -3.0 4.0 ---- ---- 13.0 0.03 20.0 ---- 26.1 0.11 32.9 150 7 1.101 0.0 ---- 4.0 ---- ---- 0.03 0.00 16.9 ---- 0.11 0.00 29.7 7 7 7.00 2R ---- 4.0 ---- ---- 13.0 0.28 16.9 ---- 26.1 1.00 29.7 150 10 1.101 2.0 ---- 11.0 ---- ---- 0.03 3.03 13.6 ---- 0.11 3.03 25.7 8 10 15.50 2LR ---- 11.0 ---- ---- 13.0 2.31 13.6 ---- 26.1 8.42 25.7 150 11 0.874 9.0 ---- 11.0 ---- ---- 0.09 0.00 11.3 ---- 0.34 0.00 17.3 9 11 42.00 4R ---- 11.0 ---- ---- 6.1 1.07 11.3 ---- 12.8 4.23 17.3 150 12 0.874 4.0 ---- 11.0 ---- ---- 0.02 0.00 10.2 ---- 0.09 0.00 13.1 10 12 5.50 B ---- 11.0 ---- ---- 0.0 0.00 10.2 ---- 0.0 0.00 13.1 150 13 0.874 3.0 ---- 11.0 ---- ---- 0.00 0.00 10.2 ---- 0.00 0.00 13.1 11 12 38.50 B5R ---- 11.0 ---- ---- 6.1 1.08 10.2 ---- 12.8 4.27 13.1 150 14 0.874 8.0 ---- 11.0 ---- ---- 0.02 0.00 9.2 ---- 0.09 0.00 8.8 12 14 9.50 R ---- 11.0 ---- ---- 0.0 0.00 9.2 ---- 13.1 1.01 8.8 150 15 0.874 1.0 ---- 11.0 4.71 ---- 0.00 0.00 9.2 13.1 0.10 0.00 7.8 13 14 13.50 B ---- 11.0 ---- ---- 6.1 0.38 9.2 ---- -0.3 0.00 8.8 150 16 0.874 3.0 ---- 11.0 ---- ---- 0.02 0.00 8.8 ---- -0.00 0.00 8.8 14 16 9.50 B ---- 11.0 ---- ---- 13.0 1.18 8.8 ---- 13.0 1.18 8.8 150 17 0.874 3.0 ---- 11.0 4.71 13.0 0.09 0.00 7.6 13.0 0.09 0.00 7.6 15 16 40.50 9R ---- 11.0 ---- ---- -6.9 1.45 8.8 ---- -13.3 4.89 8.8 150 18 0.874 9.0 ---- 11.0 ---- ---- -0.03 0.00 10.2 ---- -0.10 0.00 13.7 16 18 27.50 LB2R ---- 11.0 ---- ---- -6.9 1.07 10.2 ---- -13.3 3.61 13.7 150 11 0.874 9.0 ---- 11.0 ---- ---- -0.03 0.00 11.3 ---- -0.10 0.00 17.3 Node Notes Pipe Notes Legend: P - Pipe # DIA - Pipe Diameter EQV. LN - Pipe Equivalent Length PUMP - Pump Pressure SP - K-Factor FLOW - Flow Rate PF - Pressure Loss due to Friction PT - Total Pressure at Node LEN - Pipe Length FIT. - Pipe Fittings FIXD LOSS - Fixed Loss Device EL - Node Elevation DISCH - Discharge in gpm FL/FT - Friction Loss per Foot PE - Pressure Loss due to Elevation Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X, Y= Y, Z= The maximum velocity of water flow occurs in pipe 2 at 7.43 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 8 at 13.98 ft/s with 2 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard PAGE: C MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.874 1.00 4.00 3.00 1.00 1.00 5.00 2.00 0.00 0.00 0.00 1.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 PAGE: K MATERIAL: Copper Tube-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.995 1.00 2.00 6.00 2.00 2.00 6.00 0.00 0.00 0.00 0.00 1.481 2.00 4.00 8.00 3.00 3.00 9.00 0.00 0.00 0.00 0.00 PAGE: L MATERIAL: Copper Tube-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.265 1.00 3.00 6.00 2.00 2.00 7.00 0.00 0.00 0.00 0.00 PAGE: P MATERIAL: PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.360 2.00 8.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 2021.0.01 computer program (License No. ) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.13 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.14 gpm with 2 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure of 53.5 psi and a 7 minute flow of 218 gal. and a 10 minute flow of 311.4 gallons. The minimum pressure at any node is 7.6 psi at node 17. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 WATER SUPPLY CURVE •1 1 81.0 P 72.0 R E 63.0 S S 54.0 U R 45.0 E 36.0 P 27.0 S I 18.0 0.0 04 8 12 16 20 24 28 32 36 40 FLOW (GPM) Static = 79.7 psi, Residual = 77.5 psi @ 750 gpm (1 sprinkler flowing) (2 sprinklers flowing) A = Available Water Supply C = Available Water Supply 79.7 psi @ 18.0 gpm 79.7 psi @ 31.1 gpm B = Required Water Supply D = Required Water Supply 31.6 psi @ 18.0 gpm 53.5 psi @ 31.1 gpm FIRE SPRINKLER SYSTEMS 705 E HARRISON ST, #200 CORONA, CA 92879 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR PALO VERDE LA QUINTA, CA PLAN 2 10% TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN CALC AREA 2 Date: 9/14/2022 File No: 32292 Data File Name: Plan 2.rdf SPRINKLER SPACING 400.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 20.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 10.0 ft. SPRINKLER SPECIFICATIONS Mfr: Viking Descr: VK494 Conc.Pend.(20x20) K=4.90 Calculated K Factor for Arm-Overs & Drops: 1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee) 0.0 ft. x 0.874 in. Arm -Over: K=4.67 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC HWC: 150 WATER SUPPLY Source: Public Test Date: 3/2/22 By: CVWD Static: 79.7 psi Resid: 77.5 psi Flow: 750.0 gpm Public Main Size: 8 in Domestic Demand: 5.0 gpm at node number 5 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press. Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 20.0 18.0 13 25.0 79.7 52.0 1 20.0 18.0 13 25.0 79.7 52.0 REVIEWING AUTHORITY CITY OF LA QUINTA FIRE DEPARTMENT RESULTS OF ANALYSIS PIPE & NODE DATA * FLOW ANALYSIS * 1 sprinkler flowing * 1 sprinklers flowing FIXD P # END LEN FIT. LOSS EL SP *DISCH FLOW PF PT *DISCH FLOW PF PT HWC NOD DIA EQV.LN PUMP (FT) (K) *(GPM) FL/FT PE (PSI)*(GPM) FL/FT PE (PSI) ------------------------------------ --------------------- --------------------- 1 1 70.00 EL2BG ---- -2.0 SRCE ---- 25.0 2.23 52.0 ---- 25.0 2.23 52.0 150 2 1.481 22.0 ---- -2.0 ---- ---- 0.02 0.00 49.7 ---- 0.02 0.00 49.7 2 2 1.00 -4.0 -2.0 ---- ---- 25.0 0.17 49.7 ---- 25.0 0.17 49.7 150 3 0.995 0.0 ---- -2.0 ---- ---- 0.17 0.00 45.6 ---- 0.17 0.00 45.6 3 3 150.00 3L ---- -2.0 ---- ---- 25.0 6.39 45.6 ---- 25.0 6.39 45.6 150 4 1.360 24.0 ---- -2.0 ---- ---- 0.04 0.00 39.2 ---- 0.04 0.00 39.2 4 4 4.00 L ---- -2.0 ---- ---- 25.0 0.37 39.2 ---- 25.0 0.37 39.2 150 5 1.265 3.0 ---- 2.0 -5 5 0.05 1.73 37.1 5 0.05 1.73 37.1 5 5 2.00 R ---- 2.0 -5 5 20.0 0.20 37.1 5 20.0 0.20 37.1 150 6 1.101 1.0 ---- 4.0 ---- ---- 0.07 0.87 36.0 ---- 0.07 0.87 36.0 6 6 1.00 -3.0 4.0 ---- ---- 20.0 0.07 36.0 ---- 20.0 0.07 36.0 150 7 1.101 0.0 ---- 4.0 ---- ---- 0.07 0.00 32.9 ---- 0.07 0.00 32.9 7 7 7.00 2R ---- 4.0 ---- ---- 20.0 0.61 32.9 ---- 20.0 0.61 32.9 150 10 1.101 2.0 ---- 11.0 ---- ---- 0.07 3.03 29.3 ---- 0.07 3.03 29.3 8 10 15.50 2LR ---- 11.0 ---- ---- 20.0 5.13 29.3 ---- 20.0 5.13 29.3 150 11 0.874 9.0 ---- 11.0 ---- ---- 0.21 0.00 24.2 ---- 0.21 0.00 24.2 9 11 42.00 4R ---- 11.0 ---- ---- 13.1 4.39 24.2 ---- 13.1 4.39 24.2 150 12 0.874 4.0 ---- 11.0 ---- ---- 0.10 0.00 19.8 ---- 0.10 0.00 19.8 10 12 5.50 B ---- 11.0 ---- ---- 20.0 1.78 19.8 ---- 20.0 1.78 19.8 150 13 0.874 3.0 ---- 11.0 4.71 20.0 0.21 0.00 18.0 20.0 0.21 0.00 18.0 11 12 38.50 B5R ---- 11.0 ---- ---- -6.9 1.37 19.8 ---- -6.9 1.37 19.8 150 14 0.874 8.0 ---- 11.0 ---- ---- -0.03 0.00 21.2 ---- -0.03 0.00 21.1 12 14 9.50 R ---- 11.0 ---- ---- 0.0 0.00 21.2 ---- 0.0 0.00 21.1 150 15 0.874 1.0 ---- 11.0 ---- ---- 0.00 0.00 21.2 ---- 0.00 0.00 21.1 13 14 13.50 B ---- 11.0 ---- ---- -6.9 0.49 21.2 ---- -6.9 0.49 21.1 150 16 0.874 3.0 ---- 11.0 ---- ---- -0.03 0.00 21.6 ---- -0.03 0.00 21.6 14 16 9.50 B ---- 11.0 ---- ---- 0.0 0.00 21.6 ---- 0.0 0.00 21.6 150 17 0.874 3.0 ---- 11.0 ---- ---- 0.00 0.00 21.6 ---- 0.00 0.00 21.6 15 16 40.50 9R ---- 11.0 ---- ---- -6.9 1.46 21.6 ---- -6.9 1.46 21.6 150 18 0.874 9.0 ---- 11.0 ---- ---- -0.03 0.00 23.1 ---- -0.03 0.00 23.1 16 18 27.50 LB2R ---- 11.0 ---- ---- -6.9 1.07 23.1 ---- -6.9 1.07 23.1 150 11 0.874 9.0 ---- 11.0 ---- ---- -0.03 0.00 24.2 ---- -0.03 0.00 24.2 Node Notes Pipe Notes Legend: P - Pipe # DIA - Pipe Diameter EQV. LN - Pipe Equivalent Length PUMP - Pump Pressure SP - K-Factor FLOW - Flow Rate PF - Pressure Loss due to Friction PT - Total Pressure at Node LEN - Pipe Length FIT. - Pipe Fittings FIXD LOSS - Fixed Loss Device EL - Node Elevation DISCH - Discharge in gpm FL/FT - Friction Loss per Foot PE - Pressure Loss due to Elevation Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X, Y= Y, Z= The maximum velocity of water flow occurs in pipe 8 at 10.70 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 8 at 10.70 ft/s with 1 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard PAGE: C MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.874 1.00 4.00 3.00 1.00 1.00 5.00 2.00 0.00 0.00 0.00 1.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 PAGE: K MATERIAL: Copper Tube-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.995 1.00 2.00 6.00 2.00 2.00 6.00 0.00 0.00 0.00 0.00 1.481 2.00 4.00 8.00 3.00 3.00 9.00 0.00 0.00 0.00 0.00 PAGE: L MATERIAL: Copper Tube-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.265 1.00 3.00 6.00 2.00 2.00 7.00 0.00 0.00 0.00 0.00 PAGE: P MATERIAL: PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.360 2.00 8.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 2021.0.01 computer program (License No. ) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.07 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.10 gpm with 1 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure of 52.0 psi and a 7 minute flow of 175 gal. and a 10 minute flow of 250.0 gallons. The minimum pressure at any node is 18.0 psi at node 13. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 WATER SUPPLY CURVE •1 1 81.0 P 72.0 R E 63.0 S S 54.0 U R 45.0 E 36.0 P 27.0 S I 18.0 0.0 04 8 12 16 20 24 28 32 36 40 FLOW (GPM) Static = 79.7 psi, Residual = 77.5 psi @ 750 gpm (1 sprinkler flowing) (1 sprinklers flowing) A = Available Water Supply C = Available Water Supply 79.7 psi @ 25.0 gpm 79.7 psi @ 25.0 gpm B = Required Water Supply D = Required Water Supply 52.0 psi @ 25.0 gpm 52.0 psi @ 25.0 gpm CAL FIRE - RIVERSIDE UNIT RIVERSIDE COUNTY FIRE DEPARTMENT OFFICE OF THE FIRE MARSHAL — LA QUINTA CALIFORNIA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org October 20, 2022 Fire Sprinkler Systems Inc. 705 E Harrison St #200 Corona, CA 92879 Re: Residential Fire Sprinkler Plan Review — PALO VERDE — TR 32279 & 33336 FCMP2022-0028 / MASTER PLAN 2 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Contractor shall separately apply and pay fees for the various Production Home lots associated with this project as each will be handled under separate permit. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist Bin # City of La Quints Building 8z Safety Division P.O. Box 1504, 78-495 Calle Tampico La.Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: MASTER PLAN TYPE 2 Owner's Name: WILLIAMS HOMES A.P.Nnmber: Address:24911 STANFORD AVENUE Legal Description: MASTER PLAN TYPE 2 Contractor: FIRE SPRINKLER SYSTEMS, INC City, ST, Zip: SANTA CLARITA, CA 91355 pa Telephone: W.;£;$�., Address: 705 E. HARRISON ST. #200 Project Description: City, ST, Zip: CORONA, CA 92879 INSTALLATION OF RESIDENTIAL FIRE SPRINKLERS Telephone: 951-272-2522 {y �k ,r>Y "'`' 'f 31 HEADS / 3,866 SF State Lic. # : 684600 City Lie. #.: 762890 Arch., Engr., Designer: Address: City, ST, Zip: Telephone: State Lic. #: . ,., � z? s" Name of Contact Person: JAM I E B I S H I P Construction Type:.V_g Occupancy: R3/U Project type (eirete one): New Add'n Alter Repair Demo Sq. Ft.: 3,866 S F "St es: 1 # Units: N/A Telephone # of Contact Person: 951-272-2522 Estimated Value of Project: $3,100.00 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Reed TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amouat Structural Cales. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Cales. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan r' Review, ready for correctionslissue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.MX 11.0A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review; ready for eorrectionsAssue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees