FSS2017-0041 Griffin Ranch Plan 3 Rev 2Description: GRIFFIN RANCH / MASTER FIRE SPRINKLER / PLAN 3475 / TR 32879 Type: FIRE SPRINKLER Subtype: RESIDENTIAL -TRACT Status: FINALED Applied: 9/14/2017 AMA HOMES Approved: 9/19/2017 RGR Parcel No: 767780085 Site Address: 81181 MERV GRIFFIN WY LA QUINTA,CA 92253 Subdivision: TR 32879 Block: Lot: AW Issued: 9/19/2017 AMA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 3/13/2018 RGR Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 175 5 0 i Applied to Approved Approved to Issued Issued to Finaled 7CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES DEPOSIT MIRTA LERMA 8/13/2018 8/13/2018 DEPOSIT REFUNDED. 101-0000-22811 CLOSED. COUNCIL APPROVED A FLAT FEE STRUCTURE FOR FIRE INSPECTION AUGUST 2017. AL ML CONDITIONS CONTAC NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST SUITE 200 CORONA CA 92879 JUDYL@FIREINC.NET BILL TO FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST SUITE 200 CORONA CA 92879 JUDYL@FIREINC.NET CONTRACTOR FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST SUITE 200 CORONA CA 92879 JUDYL@FIREINC.NET Printed: Thursday, January 26, 2023 3:21:40 PM 1 of 3 WsYsrEMS FINANCIAL 1 INFORMATION CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY FIRE SPRINKLER SYSTEM RESIDENTIAL - 101-0000-22811 1 $614.00 $614.00 9/14/17 R27960 229262 CHECK FIRE SPRINKLER AMA SYSTEMS INC MODELS Total Paid for FIRE SPRINKLER SYSTEM RESIDENTIAL - $614.00 $614.00 MODELS: TECHNOLOGY 502-0000-43611 0 $5.00 $5.00 9/14/17 R27960 229262 CHECK FIRE SPRINKLER AMA ENHANCEMENT FEE SYSTEMS INC Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 • 00 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES DATE DATE OVERHEAD ROUGH RGR 1/25/2018 1/25/2018 APPROVED PIPING FIRE FINAL" RGR 3/13/2018 3/13/2018 APPROVED PARENT PROJECTS PROJECT NO PROJECTTYPE APPLIED PROJECTSUBTYPE APPROVED STATUS CLOSED PLANNER BTCP2017-0006 TRACT RESIDENTIAL 6/9/2017 STANDARD 8/28/2017 APPROVED- JAKE FUSON CONSTRUCTION PLAN CONDITIONS RETURNED REVIEW TYPE REVIEWER SENT DATE DUE DATE STATUS REMARKS Printed: Thursday, January 26, 2023 3:21:40 PM 2 of 3 WSYSiEMS DATE 1ST FIRE (2 WK) RONALD 9/14/2017 9/25/2017 9/20/2017 APPROVED GRIESINGER BOND INFORMATION V = a Fall: I in I I k, I OW Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/4/2021 JOSE DELGADO Fire Review Fire Review Application.pdf Application.pdf 0 Printed: Thursday, January 26, 2023 3:21:40 PM 3 of 3 WsYsrEMS 54 + Fire Flow Analysis hydrant GEO 6-7-15-2 WF: 652742 (PZ 17-8160) iTech: Ruben M I Ill I Lill ;;9� F4 41"E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — µA D15ON iTEEEt .v.xoT — _ CANAMRO CIRCLE SEA K%O CIRCLE N / / \ t Ln P V N i N N i IS AHSlMlD NO �� OW ��Ie CALMS o IS m Po I V N o a �4 � ' I �1 � a V iALLZ1Y E31SS}lY y a a y � V P U A 41 N "• �Y1 � N�gR�gre� u Er U m S S S S S S S S U O m DN 5. HusiH�.0 m m m C _ # A In Y N _ y p U U U P a P U m' o 0 m A •;C. o j n � OOOOpO00pL". � Z AS. f m n s"jsNm'_o� S z N �r p In O v G O N pN V p W JtiE a A ,A a m a .e v G p N N y30'I�lYAY7 N m 2 Z a N Z O o ....m o in 4 Y m v 0 � V V W N N N m N y Y N N .PY. x01 V I M SZ b W N N j G L V N m V o N Y U WAT MERV GRLEpN N 51 3ASYD �NYO En .Vi '�(Q V � "p m V V f� DAM S PAR DIMV J U SS MADAGASCAR WAY � � - A •• r pp A pmVn ; pip I � I N G 1�, a WELL SDE ` ' M pk4VE ARpSH NAa Ipl DlIVE "AI" Dots 061201201 IDMSA CONSULTWO, INC CONSTRUCTION PHASING EXHIBIT PL mim ■ Omm Emav Laa[O ■ LUm 9[¢veram " 342M Boa lion Duval n Itmamo MuAm . CA 9n7O G R O F F I N RANCH — L E N N A R 7Y�re7.v� 060) 37D-NU ■ FAx C76M 323-7M rY�AT'E Domestic Water System Flow Analysis Domestic Water System FlowAna€ysis (Hydraulic Model) Requested By: I FIRE SPRINKLERS SYSTEMS, INC. Address: 705 E. HARRISON STREET CORONA, CA 92879 Contact Name: JAMIE BISHIP Phone: 800-915-3473 Email: jamieb@fireinc.net Coachella Valley Water District 75515 Hovley Lane East Palm Desert, CA 92211 Date: 7/18/17 APN: Req. Fire Flow: 1000gpm at 20psi fort hours, Project Name: I GRIFFIN RANCH Cell: Domestic Water System HYDRANT AT THE NE CORNER OF MERV GRIFFIN WAY AND DAMASCUS DRIVE, La Quinta, GEO Flow Analysis Location: 6-7-15-2, PZ 17-8160 Model Information Flow Analysis Description r rr' Requested • Test 1 Test 2 Test 3 Test 4 Flow Domestic Elevation (Ft): -16 system flow Steady State, Dynamic (psi): 82.8 None available Residual Pressure (psi): 74.82 without Fire Flow Tested (gpm): 2,300 exceeding N/A CVWD's Combined Total: N/A criteria. Tested Model Junction: J1828 Duration: 2 hours Demand Conditions: Peak Day Demand (PDD) Reservoir No./Level (s): Reservoir 6726 Pumps Operating No's: Pumps On Pressure Zone and HGL: Lake Cahuilla (145') — - Model: MervGriffin&Damascus-CVWD_DomesticWater_012616 Comments: The domestic water system is capable of providing 2,300 gpm for 2 hours that satisfies CVWD's minimum pressure, velocity, and/or head loss criteria. This flow can be achieved by using multiple fire hydrants. This simulated system flow analysis may not include all facilities that may be required for this development/project. Please check with Development Services for further information on all required facilities: The theoretical flow to drop the residual pressure to 20 psi is greater than 5,000 gpm. Please note the theoretical flow exceeds CVWD's design criteria on the domestic water network. These results are based on hydraulic modelling and not a guarantee that CVWD's domestic water system will have the capacity to supply water to the project at the flows or pressures indicated. It is important to note that the capacity of the on -site fire system, meters, service lines, backflow assemblies and other appurtenances were not considered in this analysis, which may alter actual flows or pressures. Due to continuous changes in the system, CVWD only considers this system flow analysis valid for six months from date of modelling/analysis. These system flow analysis comments are for plan check purposes only. The ultimate design responsibility resides with the Engineer -of -Record for this Project. Should you have any questions or need additional information, please contact me at (760) 398-2661, ext. 2397. 6 2 01�8 Completed By: _ ,•,; Date: IF LI? 7 coIA J!llNYV? Page 1 of 1 ENG DS-016 (8/31/15) Qsz"CS V* DATE: 8/29/2017 S:\2017\31586\CALL\3475.rdf Page 1 FIRE SPRINKLER SYSTEMS 705 E. HARRISON, SUITE 200 CORONA,CA 92879 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR GRIFFIN RANCH LA QUINTA, CA PLAN 3475 10% TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN CALC AREA 1 Date: 8/29/2017 File No: 31586 Data File Name: 3475.rdf SPRINKLER SPACING 256.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 16.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 8.0 ft. SPRINKLER SPECIFICATIONS Mfr: Reliable Descr: RA0616 RFC49 F1 Conc .Pend.(16xl6) K=4.90 Calculated K Factor for Arm-Overs & Drops: 1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee) 0.0 ft. x 0.874 in. Arm -Over: K=4.67 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 74.5 psi Resid: 67.3 psi F1ow:2300.0 gpm Public Main Size: 8 in Domestic Demand: 5.0 gpm at node number 104 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press. Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 13.0 7.6 18 18.0 74.5 34.3 2 13.0 7.6 18 31.3 74.5 61.4 REVIEWING AUTHORITY CITY OF LA QUINTA FIRE DEPT. DATE: 8/29/2017 S:\2017\31586\CALC\3475.rdf Page 2 RESULTS OF ANALYSIS PIPE & NODE DATA * FLOW ANALYSIS * 1 sprinkler flowing * 2 sprinklers flowing FIXD P # END LEN FIT. LOSS EL SP *DISCH FLOW PF PT *DISCH FLOW PF PT HWC NOD DIA EQV.LN PUMP (FT) (K) *(GPM) FL/FT PE (PSI)*(GPM) FL/FT PE (PSI) 1 100 30.00 BG ---- -2.0 SRCE ---- 18.0 3.29 34.3 ---- 31.2 9.15 61.4 150 101 0.995 6.0 ---- -2.0 ---- ---- 0.09 0.00 31.1 ---- 0.25 0.00 52.2 2 101 1.00 -4.0 -2.0 ---- ---- 18.0 0.09 31.1 ---- 31.3 0.25 52.2 150 102 0.995 0.0 ---- -2.0 ---- ---- 0.09 0.00 27.0 ---- 0.25 0.00 48.0 3 102 70.00 3L ---- -2.0 ---- ---- 18.0 1.88 27.0 ---- 31.3 5.22 48.0 150 103 1.360 24.0 ---- -2.0 ---- ---- 0.02 0.00 25.1 ---- 0.06 0.00 42.7 4 103 4.00 LG ---- -2.0 ----- ---- 18.0 0.20 25.1 ---- 31.3 0.55 42.7 150 104 1.265 3.0 ---- 2.0 -5 5 0.03 1.73 23.1 5 0.08 1.73 40.4 5 104 2.00 L ---- 2.0 -5 5 13.0 0.21 23.1 5 26.3 0.79 40.4 150 105 1.101 5.0 ---- 4.0 ---- ---- 0.03 0.87 22.1 ---- 0.11 0.87 38.8 6 105 1.00 -3.0 4.0 ---- ---- 13.0 0.03 22.1 ---- 26.3 0.11 38.8 150 106 1.101 0.0 ---- 4.0 ---- ---- 0.03 0.00 19.0 ---- 0.11 0.00 35.7 7 106 7.00 2L ---- 4.0 ---- ---- 13.0 0.52 19.0 ---- 26.3 1.91 35.7 150 10 1.101 10.0 ---- 11.0 ----- ---- 0.03 3.03 15.5 ---- 0.11 3.03 30.7 8 10 9.00 LR ---- 11.0 ---- ---- 13.0 1.32 15.5 ---- 26.3 4.85 30.7 150 11 0.874 5.0 ---- 11.0 ---- ---- 0.09 0.00 14.2 ---- 0.35 0.00 25.9 9 11 15.00 BR ---- 11.0 ---- ---- 6.1 0.44 14.2 ---- 12.7 1.71 25.9 150 12 0.874 4.0 ---- 11.0 ----- ---- 0.02 0.00 13.7 ---- 0.09 0.00 24.2 10 12 2.00 L ---- 11.0 ---- ---- 6.1 0.14 13.7 ---- 12.7 0.54 24.2 150 13 0.874 4.0 ---- 13.0 ---- ---- 0.02 0.87 12.7 ---- 0.09 0.87 22.8 11 13 106.50 3LB7R ---- 13.0 ---- ---- 6.1 2.99 12.7 ---- 12.7 11.57 22.8 150 14 0.874 22.0 ---- 13.0 ---- ---- 0.02 0.00 9.7 ---- 0.09 0.00 11.2 12 14 22.00 L3R _--- 13.0 ---- ---- 6.1 0.67 9.7 ---- 12.7 2.61 11.2 150 15 0.874 7.0 ---- 13.0 ---- ---- 0.02 0.00 9.0 ---- 0.09 0.00 8.6 13 15 6.00 R ---- 13.0 ---- ---- 0.0 0.00 9.0 ---- 13.3 0.68 8.6 150 16 0.874 1.0 ---- 13.0 4.71 ---- 0.00 0.00 9.0 13.3 0.10 0.00 7.9 14 15 14.50 B2R ---- 13.0 ----- ---- 6.1 0.45 9.0 ---- -0.6 0.01 8.6 150 17 0.874 5.0 ------ 13.0 ---- ---- 0.02 0.00 8.6 ---- 0.00 0.00 8.6 15 17 6.50 EB ---- 13.0 ---- ---- 13.0 0.99 8.6 ---- 13.0 0.99 8.6 150 18 0.874 4.0 ---- 13.0 4.71 13.0 0.09 0.00 7.6 13.0 0.09 0.00 7.6 16 17 17.00 BR ---- 13.0 ---- ---- -6.9 0.61 8.6 ---- -13.6 2.15 8.6 150 19 0.874 4.0 ---- 13.0 ---- ---- -0.03 0.00 9.2 ---- -0.10 0.00 10.7 17 19 3.50 B ---- 13.0 ---- ---- 0.0 0.00 9.2 ---- 0.0 0.00 10.7 DATE: 8/29/2017 S:\2017\31586\CALC\3475.rdf Page 3 150 20 0.874 3.0 ---- 13.0 _--- ---- 0.00 0.00 9.2 ---- 0.00 0.00 10.7 18 19 23.50 3R ---- 13.0 ---- ---- -6.9 0.78 9.2 ---- -13.6 2.71 10.7 150 21 0.874 3.0 ---- 13.0 ---- ---- -0.03 0.00 10.0 ---- -0.10 0.00 13.5 19 21 2.00 L ---- 13.0 ---- ---- -6.9 0.18 10.0 ---- -13.6 0.61 13.5 150 22 0.874 4.0 ---- 11.0 ---- ---- -0.03 0.87 11.0 ---- -0.10 0.87 14.9 20 22 39.50 LB6R ---- 11.0 ---- ---- -6.9 1.54 11.0 ---- -13.6 5.37 14.9 150 23 0.874 13.0 ---- 11.0 ---- ---- -0.03 0.00 12.6 ---- -0.10 0.00 20.3 21 23 37.50 2LB6R ---- 11.0 ---- ---- -6.9 1.59 12.6 ---- -13.6 5.58 20.3 150 11 0.874 17.0 ---- 11.0 ---- ---- -0.03 0.00 14.2 ---- -0.10 0.00 25.9 Legend: P - Pipe # DIA - Pipe Diameter EQV. LN - Pipe Equivalent Length PUMP - Pump Pressure SP - K-Factor FLOW - Flow Rate PF - Pressure Loss due to Friction PT - Total Pressure at Node Node Notes Pipe Notes LEN - Pipe Length FIT. - Pipe Fittings FIXD LOSS - Fixed Loss Device EL - Node Elevation DISCH - Discharge in gpm FL/FT - Friction Loss per Foot PE - Pressure Loss due to Elevation Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X, Y= Y, The maximum velocity of water flow occurs in pipe 2 at 7.43 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 8 at 14.04 ft/s with 2 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt PAGE: C MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.874 1.00 4.00 3.00 1.00 1.00 5.00 2.00 0.00 0.00 0.00 1.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 PAGE: K MATERIAL: Copper Tube-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.995 1.00 2.00 6.00 2.00 2.00 6.00 0.00 0.00 0.00 0.00 DATE: 8/29/2017 S:\2017\31586\CALL\3475.rdf Page 4 PAGE: L MATERIAL: Copper Tube-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.265 1.00 3.00 6.00 2.00 2.00 7.00 0.00 0.00 0.00 0.00 PAGE: P MATERIAL: PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.360 2.00 8.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.7.0 computer program (License No. 50081444 ) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.11 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.07 gpm with 2 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure of 61.4 psi and a 7 minute flow of 219 gal. and a 10 minute flow of 312.5 gallons. The minimum pressure at any node is 7.6 psi at node 18. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 DATE: 8/Z9/2017 S:\2017\31586\CALL\3475.rdf Page 5 75.0 0 1 67.5 I D R60.0 E I 552.5 S 1 U45.0 R E37.5 I B (30.0 p I 522.5 2 15I. 0 7.5 0. C4 8 12 16 20 24 28 32 36 40 FLOW (GPM) 74.5 psi, Resiuual = oi.3 psi @ 2300 qpm r flowing) (2 sprinklers flowing) = Available WatC = Available Water Supply 74.5 psi @ 18.0 c74.5 psi @ 31.3 qpm = Required WateD = Required Water Supply 34.3 psi Q 18.0 c61.4 psi Q 31.3 gpm DATE: 8/�9/2017 S:\2017\31586\CALC\3475.rdf Page 6 DATE: 8/2.9/2017 S:\2017\31586\CALC\3475.rdf Page 1 FIRE SPRINKLER SYSTEMS 705 E. HARRISON, SUITE 200 CORONA,CA 92879 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR GRIFFIN RANCH LA QUINTA, CA PLAN 3475 10% TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN CALC AREA 2 Date: 8/29/2017 File No: 31586 Data File Name: 3475.rdf SPRINKLER SPACING 400.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 20.0 ft. Min. Dist. Bet. Spklrs: 10.0 Max. Dist. Spklr. to Wall: 10.0 ft. SPRINKLER SPECIFICATIONS Mfr: Reliable Descr: RA0616 RFC49 F1 Conc .Pend.(20x2O) K=4.90 Calculated K Factor for Arm-Overs & Drops: 1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee) 0.0 ft. x 0.874 in. Arm -Over: K=4.67 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 74.5 psi Resid: 67.3 psi F1ow:2300.0 gpm Public Main Size: 8 in Domestic Demand: 5.0 gpm at node number 104 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press. Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 20.0 18.0 20 25.0 74.5 57.6 1 20.1 18.1 20 25.1 74.5 58.0 REVIEWING AUTHORITY CITY OF LA QUINTA FIRE DEPT. DATE: 8/29/2017 S:\2017\31586\CALL\3475.rdf Page 2 RESULTS OF ANALYSIS PIPE & NODE DATA * FLOW ANALYSIS * 1 sprinkler flowing * 1 sprinklers flowing FIXD P # END LEN FIT. LOSS EL SP *DISCH FLOW PF PT *DISCH FLOW PF PT HWC NOD DIA EQV.LN PUMP (FT) (K) *(GPM) FL/FT PE (PSI)*(GPM) FL/FT PE (PSI) 1 100 30.00 BG ---- -2.0 SRCE ---- 25.0 6.06 57.6 ---- 25.1 6.12 58.0 150 101 0.995 6.0 ---- -2.0 ---- ---- 0.17 0.00 51.6 ---- 0.17 0.00 51.9 2 101 1.00 -4.0 -2.0 ---- ---- 25.0 0.17 51.6 ---- 25.1 0.17 51.9 150 102 0.995 0.0 ---- -2.0 ---- ---- 0.17 0.00 47.4 ---- 0.17 0.00 47.7 3 102 70.00 3L ---- -2.0 ---- ---- 25.0 3.45 47.4 ---- 25.1 3.47 47.7 150 103 1.360 24.0 ---- -2.0 ------ ---- 0.04 0.00 44.0 ---- 0.04 0.00 44.2 4 103 4.00 LG - -- -2.0 ---- ---- 25.0 0.37 44.0 ---- 25.1 0.37 44.2 150 104 1.265 3.0 ---- 2.0 -5 5 0.05 1.73 41.9 5 0.05 1.73 42.1 5 104 2.00 L ---- 2.0 -5 5 20.0 0.48 41.9 5 20.1 0.48 42.1 150 105 1.101 5.0 ---- 4.0 ---- ---- 0.07 0.87 40.5 ---- 0.07 0.87 40.8 6 105 1.00 -3.0 4.0 ---- ---- 20.0 0.07 40.5 ---- 20.1 0.07 40.8 150 106 1.101 0.0 - -- 4.0 ---- ---- 0.07 0.00 37.4 ---- 0.07 0.00 37.7 7 106 7.00 2L ---- 4.0 ---- ---- 20.0 1.16 37.4 ---- 20.1 1.16 37.7 150 10 1.101 10.0 ---- 11.0 ---- ---- 0.07 3.03 33.3 ---- 0.07 3.03 33.5 8 10 9.00 LR ---- 11.0 ---- ---- 20.0 2.93 33.3 ---- 20.1 2.95 33.5 150 11 0.874 5.0 ---- 11.0 ---- ---- 0.21 0.00 30.3 ---- 0.21 0.00 30.5 9 11 15.00 BR ---- 11.0 ---- ---- 8.7 0.86 30.3 ---- 8.8 0.87 30.5 150 12 0.874 4.0 ----- 11.0 ---- ---- 0.05 0.00 29.5 ---- 0.05 0.00 29.7 10 12 2.00 L ---- 11.0 ---- ---- 8.7 0.27 29.5 ---- 8.8 0.27 29.7 150 13 0.874 4.0 ---- 13.0 ----- •---- 0.05 0.87 28.3 ---- 0.05 0.87 28.5 11 13 106.50 3LB7R ---- 13.0 ---- ---- 8.7 5.82 28.3 ---- 8.8 5.86 28.5 150 14 0.874 22.0 ---- 13.0 ---- ---- 0.05 0.00 22.5 ---- 0.05 0.00 22.7 12 14 22.00 L3R ---- 13.0 ---- ---- 8.7 1.31 22.5 ---- 8.8 1.32 22.7 150 15 0.874 7.0 ---- 13.0 ---- ---- 0.05 0.00 21.2 ---- 0.05 0.00 21.4 13 15 6.00 R ---- 13.0 ---- ---- 0.0 0.00 21.2 ---- 0.0 0.00 21.4 150 16 0.874 1.0 ---- 13.0 ---- ---- 0.00 0.00 21.2 ---- 0.00 0.00 21.4 14 15 14.50 B2R ---- 13.0 ---- ---- 8.7 0.88 21.2 ---- 8.8 0.89 21.4 150 17 0.874 5.0 ---- 13.0 ---- ---- 0.05 0.00 20.3 ---- 0.05 0.00 20.5 15 17 6.50 EB ---- 13.0 ---- ---- 0.0 0.00 20.3 ---- 0.0 0.00 20.5 150 18 0.874 4.0 ---- 13.0 ---- -•--- 0.00 0.00 20.3 ---- 0.00 0.00 20.5 16 17 17.00 BR ---- 13.0 ---- -•--- 8.7 0.95 20.3 ---- 8.8 0.96 20.5 150 19 0.874 4.0 -•--- 13.0 ---- ---- 0.05 0.00 19.4 ---- 0.05 0.00 19.5 17 19 3.50 B ---- 13.0 ---- ---- 20.0 1.36 19.4 ---- 20.1 1.37 19.5 DATE: 8/29/2017 S:\2017\31586\CALL\3475.rdf Page 3 150 20 0.874 3.0 ---- 13.0 4.71 20.0 0.21 0.00 18.0 20.1 0.21 0.00 18.1 18 19 23.50 3R ---- 13.0 ---- ---- -11.3 1.92 19.4 ---- -11.3 1.93 19.5 150 21 0.874 3.0 ---- 13.0 ---- ---- -0.07 0.00 21.3 ---- -0.07 0.00 21.4 19 21 2.00 L ---- 13.0 ---- ---- -11.3 0.43 21.3 ---- -11.3 0.44 21.4 150 22 0.874 4.0 ---- 11.0 ---- _--- -0.07 0.87 22.6 ---- -0.07 0.87 22.7 20 22 39.50 LB6R ---- 11.0 ---- ---- -11.3 3.80 22.6 ---- -11.3 3.83 22.7 150 23 0.874 13.0 ---- 11.0 ---- ---- -0.07 0.00 26.4 ---- -0.07 0.00 26.6 21 23 37.50 2LB6R ---- 11.0 ---- ---- -11.3 3.94 26.4 ---- -11.3 3.97 26.6 150 11 0.874 17.0 ---- 11.0 ---- ---- -0.07 0.00 30.3 ---- -0.07 0.00 30.5 Legend: P - Pipe # DIA - Pipe Diameter EQV. LN - Pipe Equivalent Length PUMP - Pump Pressure SP - K-Factor FLOW - Flow Rate PF - Pressure Loss due to Friction PT - Total Pressure at Node Fitting Code Letters: Node Notes Pipe Notes LEN - Pipe Length FIT. - Pipe Fittings FIXD LOSS - Fixed Loss Device EL - Node Elevation DISCH - Discharge in gpm FL/FT - Friction Loss per Foot PE - Pressure Loss due to Elevation E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X, Y= Y, Z The maximum velocity of water flow occurs in pipe 8 at 10.70 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 8 at 10.74 ft/s with 1 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt PAGE: C MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.874 1.00 4.00 3.00 1.00 1.00 5.00 2.00 0.00 0.00 0.00 1.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 PAGE: K MATERIAL: Copper Tube-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.995 1.00 2.00 6.00 2.00 2.00 6.00 0.00 0.00 0.00 0.00 DATE: 8/2.9/2017 S:\2017\31586\CALC\3475.rdf Page 4 PAGE: L MATERIAL: Copper Tube-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.265 1.00 3.00 6.00 2.00 2.00 7.00 0.00 0.00 0.00 0.00 PAGE: P MATERIAL: PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.360 2.00 8.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.7.0 computer program (License No. 50081444 ) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.01 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.19 gpm with 1 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure of 58.0 psi and a 7 minute flow of 176 gal. and a 10 minute flow of 250.8 gallons. The minimum pressure at any node is 18.1 psi at node 20. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 DATE: 8/29/2017 S:\2017\31586\CALC\3475.rdf Page 5 75.01 67.51 P 60.0 R E 52.5 S S 45.0 U R 37.5 E { 30.0 P 22.5 S I 15.0 } 7.5 0.0 04 8 12 16 20 WATER SUPPLY CURVE C- (PD 24 28 32 FLOW (GPM) 36 40 Static = 74.5 psi, Residual = 67.3 psi @ 2300 gpm (1 sprinkler flowing) (1 sprinklers flowing) A = Available Water Supply C = Available Water Supply 74.5 psi @ 25.0 gpm 74.5 psi @ 25.1 gpm B = Required Water Supply D = Required Water Supply 57.6 psi @ 25.0 gpm 58.0 psi @ 25.1 gpm DATE: 8/29/2017 S:\2017\31586\CALC\3475.rdf Page 6 DATE: 10/31/2018 S:\2017\31586\CALC\3475_ALT.rdf Page 1 FIRE SPRINKLER SYSTEMS 705 E. HARRISON, SUITE 200 CORONA,CA 92879 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR GRIFFIN RANCH LA QUINTA, CA PLAN 3475_ALT 109. TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN CALC AREA 1 Date: 10/31/2018 File No: 31586 Data File Name: 3475 ALT.rdf SPRINKLER SPACING 256.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 16.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 8.0 ft. SPRINKLER SPECIFICATIONS Mfr: Reliable Descr: RA0616 RFC49 F1 Conc .Pend.(16xl6) K=4.90 Calculated K Factor for Arm-Overs & Drops: 1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee) 0.0 ft. x 0.874 in. Arm -Over: K=4.67 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 74.5 psi Resid: 67.3 psi F1ow:2300.0 gpm Public Main Size: 8 in Domestic Demand: 5.0 gpm at node number 104 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press. Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 13.0 7.6 18 18.0 74.5 39.3 2 13.0 7.6 18 31.3 74.5 64.5 REVIEWING AUTHORITY CITY OF LA QUINTA FIRE DEPT. DATE: 10/31/2018 S:\2017\31586\CALL\3475_ALT.rdf Page 2 RESULTS OF ANALYSIS PIPE & NODE DATA * FLOW ANALYSIS * 1 sprinkler flowing * 2 sprinklers flowing FIXD P # END LEN FIT. LOSS EL SP *DISCH FLOW PF PT *DISCH FLOW PF PT HWC NOD DIA EQV.LN PUMP (FT) (K) *(GPM) FL/FT PE (PSI)*(GPM) FL/FT PE (PSI) ------------------------------------ 1 100 30.00 BG ---- -2.0 SRCE ---- 18.0 3.29 39.3 ---- 31.2 9.14 64.5 150 101 0.995 6.0 ---- -2.0 ---- ---- 0.09 0.00 36.0 ---- 0.25 0.00 55.3 2 101 1.00 -9.5 -2.0 ---- ---- 18.0 0.38 36.0 ---- 31.3 1.04 55.3 150 102 0.745 0.0 ---- -2.0 ---- ---- 0.38 0.00 26.1 ---- 1.04 0.00 44.8 3 102 70.00 3L -_-- -2.0 ---- ---- 18.0 1.88 26.1 ---- 31.3 5.22 44.8 150 103 1.360 24.0 ---- -2.0 ---- ---- 0.02 0.00 24.2 ---- 0.06 0.00 39.6 4 103 4.00 LG ---- -2.0 ••-- ---- 18.0 0.20 24.2 ---- 31.3 0.55 39.6 150 104 1.265 3.0 ---- 2.0 -5 5 0.03 1.73 22.3 5 0.08 1.73 37.3 5 104 2.00 L ---- 2.0 -5 5 13.0 0.21 22.3 5 26.3 0.79 37.3 150 105 1.101 5.0 ---- 4.0 ---- ---- 0.03 0.87 21.2 ---- 0.11 0.87 35.6 6 105 1.00 -3.0 4.0 ---- ---- 13.0 0.03 21.2 ---- 26.3 0.11 35.6 150 106 1.101 0.0 ---- 4.0 ---- ---- 0.03 0.00 18.2 ---- 0.11 0.00 32.5 7 106 7.00 2L ---- 4.0 ---- ---- 13.0 0.52 18.2 ---- 26.3 1.91 32.5 150 10 1.101 10.0 ---- 11.0 ---- ---- 0.03 3.03 14.6 ---- 0.11 3.03 27.6 8 10 9.00 LR ---- 11.0 ---- ---- 13.0 0.46 14.6 ---- 26.3 1.69 27.6 150 11 1.101 6.0 ---- 11.0 ---- ---- 0.03 0.00 14.2 ---- 0.11 0.00 25.9 9 11 15.00 BR ---- 11.0 ---- ---- 6.1 0.44 14.2 ---- 12.7 1.71 25.9 150 12 0.874 4.0 ---- 11.0 ---- ---- 0.02 0.00 13.7 ---- 0.09 0.00 24.2 10 12 2.00 L ---- 11.0 ---- ---- 6.1 0.14 13.7 ---- 12.7 0.54 24.2 150 13 0.874 4.0 ---- 13.0 ---- ---- 0.02 0.87 12.7 ---- 0.09 0.87 22.8 11 13 106.50 3LB7R ---- 13.0 ---- ---- 6.1 2.99 12.7 ---- 12.7 11.57 22.8 150 14 0.874 22.0 ---- 13.0 ---- ---- 0.02 0.00 9.7 ---- 0.09 0.00 11.2 12 14 22.00 L3R ---- 13.0 ---- ---- 6.1 0.67 9.7 ---- 12.7 2.61 11.2 150 15 0.874 7.0 ---- 13.0 ---- ---- 0.02 0.00 9.1 ---- 0.09 0.00 8.6 13 15 6.00 R ---- 13.0 ---- ---- 0.0 0.00 9.1 ---- 13.3 0.68 8.6 150 16 0.874 1.0 ---- 13.0 4.71 ---- 0.00 0.00 9.1 13.3 0.10 0.00 7.9 14 15 14.50 B2R ---- 13.0 ---- ---- 6.1 0.45 9.1 ---- -0.6 0.01 8.6 150 17 0.874 5.0 ---- 13.0 ---- ---- 0.02 0.00 8.6 ---- 0.00 0.00 8.6 15 17 6.50 EB ---- 13.0 ---- ---- 13.0 0.99 8.6 ---- 13.0 0.99 8.6 150 18 0.874 4.0 ---- 13.0 4.71 13.0 0.09 0.00 7.6 13.0 0.09 0.00 7.6 16 17 17.00 BR ---- 13.0 ---- ---- -6.9 0.61 8.6 ---- -13.6 2.15 8.6 150 19 0.874 4.0 --- 13.0 ---- ---- -0.03 0.00 9.2 ---- -0.10 0.00 10.8 17 19 3.50 B ---- 13.0 ---- ---- 0.0 0.00 9.2 ---- 0.0 0.00 10.8 DATE: 10/31/2018 S:\2017\31586\CALC\3475_ALT.rdf Page 3 150 20 0.874 3.0 ---- 13.0 ---- ---- 0.00 0.00 9.2 ---- 0.00 0.00 10.8 18 19 23.50 3R ---- 13.0 ---- ---- -6.9 0.78 9.2 ---- -13.6 2.71 10.8 150 21 0.874 3.0 ---- 13.0 ---- ---- -0.03 0.00 10.0 ---- -0.10 0.00 13.5 19 21 2.00 L ---- 13.0 ---- -- -6.9 0.18 10.0 ---- -13.6 0.61 13.5 150 22 0.874 4.0 ---- 11.0 ---- ---- -0.03 0.87 11.0 ---- -0.10 0.87 15.0 20 22 39.50 LB6R ---- 11.0 ---- ---- -6.9 1.54 11.0 ---- -13.6 5.37 15.0 150 23 0.874 13.0 ---- 11.0 ---- ---- -0.03 0.00 12.6 ---- -0.10 0.00 20.3 21 23 37.50 2LB6R ---- 11.0 ---- ---- -6.9 1.59 12.6 ---- -13.6 5.58 20.3 150 11 0.874 17.0 ---- 11.0 ---- ---- -0.03 0.00 14.2 ---- -0.10 0.00 25.9 Legend: P - Pipe # DIA - Pipe Diameter EQV. LN - Pipe Equivalent Length PUMP - Pump Pressure SP - K-Factor FLOW - Flow Rate PF - Pressure Loss due to Friction PT - Total Pressure at Node Node Notes Pipe Notes LEN - Pipe Length FIT. - Pipe Fittings FIXD LOSS - Fixed Loss Device EL - Node Elevation DISCH - Discharge in gpm FL/FT - Friction Loss per Foot PE - Pressure Loss due to Elevation Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X, Y= Y, Z The maximum velocity of water flow occurs in pipe 2 at 13.25 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 2 at 23.00 ft/s with 2 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt PAGE: C MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.874 1.00 4.00 3.00 1.00 1.00 5.00 2.00 0.00 0.00 0.00 1.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 PAGE: K MATERIAL: Copper Tube-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.745 0.00 1.00 3.00 1.00 1.00 0.00 0.00 0.00 0.00 0.00 0.995 1.00 2.00 6.00 2.00 2.00 6.00 0.00 0.00 0.00 0.00 DATF,: 10/31/2018 S:\2017\31586\CALC\3475_ALT.rdf Page 4 PAGE: L MATERIAL: Copper Tube-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet ( in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.265 1.00 3.00 6.00 2.00 2.00 7.00 0.00 0.00 0.00 0.00 PAGE: P MATERIAL: PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.360 2.00 8.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.8.0 computer program (License No. 50081444 ) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.16 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.11 gpm with 2 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure of 64.5 psi and a 7 minute flow of 219 gal. and a 10 minute flow of 312.5 gallons. The minimum pressure at any node is 7.6 psi at node 18. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 DATE: 10/31/2018 S:\2017\31586\CALC\3475—ALT.rdf Page l FIRE SPRINKLER SYSTEMS 705 E. HARRISON, SUITE 200 CORONA,CA 92879 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR GRIFFIN RANCH LA QUINTA, CA PLAN 3475_ALT 10% TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN CALL AREA 2 Date: 10/31/2018 File No: 31586 Data File Name: 3475 ALT.rdf SPRINKLER SPACING 400.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 20.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 10.0 ft. SPRINKLER SPECIFICATIONS Mfr: Reliable Descr: RA0616 RFC49 Fl Conc .Pend.(20x20) K=4.90 Calculated K Factor for Arm-Overs & Drops: 1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee) 0.0 ft. x 0.874 in. Arm -Over: K=4.67 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 74.5 psi Resid: 67.3 psi F1ow:2300.0 gpm Public Main Size: 8 in Domestic Demand: 5.0 gpm at node number 104 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press Flowing Flow (psi) 1 20.0 18.0 1 20.0 18.0 REVIEWING AUTHORITY CITY OF LA QUINTA FIRE DEPT. Node Total Avail. Req'd No. Flow Press. Press. 20 25.0 74.5 61.7 20 25.0 74.5 61.7 DATE: 10/31/2018 S:\2017\31586\CALL\3475_ALT.rdf Page 2 RESULTS OF ANALYSIS PIPE & NODE DATA * FLOW ANALYSIS * 1 sprinkler flowing * 1 sprinklers flowing FIXD P # END LEN FIT. LOSS EL SP *DISCH FLOW PF PT *DISCH FLOW PF PT HWC NOD DIA EQV.LN PUMP (FT) (K) *(GPM) FL/FT PE (PSI)*(GPM) FL/FT PE (PSI) 1 100 30.00 BG ---- -2.0 SRCE ---- 25.0 6.06 61.7 ---- 25.0 6.04 61.7 150 101 0.995 6.0 ---- -2.0 ---- ---- 0.17 0.00 55.7 ---- 0.17 0.00 55.7 2 101 1.00 -9.5 -2.0 ---- ---- 25.0 0.69 55.7 ---- 25.0 0.69 55.7 150 102 0.745 0.0 ---- -2.0 ---- ---- 0.69 0.00 45.5 ---- 0.69 0.00 45.5 3 102 70.00 3L ---- -2.0 ---- ---- 25.0 3.45 45.5 ---- 25.0 3.45 45.5 150 103 1.360 24.0 ---- -2.0 ---- ---- 0.04 0.00 42.0 ---- 0.04 0.00 42.0 4 103 4.00 LG ---- -2.0 ---- ---- 25.0 0.37 42.0 ---- 25.0 0.37 42.0 150 104 1.265 3.0 ---- 2.0 -5 5 0.05 1.73 39.9 5 0.05 1.73 39.9 5 104 2.00 L ---- 2.0 -5 5 20.0 0.48 39.9 5 20.0 0.48 39.9 150 105 1.101 5.0 ---- 4.0 ---- ---- 0.07 0.87 38.6 ---- 0.07 0.87 38.6 6 105 1.00 -3.0 4.0 ---- ---- 20.0 0.07 38.6 ---- 20.0 0.07 38.6 150 106 1.101 0.0 - -- 4.0 ---- ---- 0.07 0.00 35.5 ---- 0.07 0.00 35.5 7 106 7.00 2L -- - 4.0 ---- ---- 20.0 1.16 35.5 ---- 20.0 1.16 35.5 150 10 1.101 10.0 --- 11.0 ---- ---- 0.07 3.03 31.3 ---- 0.07 3.03 31.3 8 10 9.00 LR ---- 11.0 ---- ---- 20.0 1.02 31.3 ---- 20.0 1.02 31.3 150 11 1.101 6.0 ---- 11.0 ---- ---- 0.07 0.00 30.3 ---- 0.07 0.00 30.3 9 11 15.00 BR ---- 11.0 ---- ---- 8.7 0.86 30.3 - - 8.7 0.86 30.3 150 12 0.874 4.0 ---- 11.0 -- - ---- 0.05 0.00 29.5 ---- 0.05 0.00 29.5 10 12 2.00 L ---- 11.0 ---- ---- 8.7 0.27 29.5 ---- 8.7 0.27 29.5 150 13 0.874 4.0 ---- 13.0 ---- ---- 0.05 0.87 28.3 ---- 0.05 0.87 28.3 11 13 106.50 3LB7R ---- 13.0 ---- ---- 8.7 5.82 28.3 ---- 8.7 5.82 28.3 150 14 0.874 22.0 ---- 13.0 -- - ---- 0.05 0.00 22.5 ---- 0.05 0.00 22.5 12 14 22.00 L3R ---- 13.0 -- - ---- 8.7 1.31 22.5 ---- 8.7 1.31 22.5 150 15 0.874 7.0 ---- 13.0 ---- ---- 0.05 0.00 21.2 ---- 0.05 0.00 21.2 13 15 6.00 R --- 13.0 ---- ---- 0.0 0.00 21.2 ---- 0.0 0.00 21.2 150 16 0.874 1.0 --- 13.0 ---- ---- 0.00 0.00 21.2 ---- 0.00 0.00 21.2 14 15 14.50 B2R ---- 13.0 ---- ---- 8.7 0.88 21.2 ---- 8.7 0.88 21.2 150 17 0.874 5.0 ---- 13.0 ---- ---- 0.05 0.00 20.3 ---- 0.05 0.00 20.3 15 17 6.50 EB ---- 13.0 ---- ---- 0.0 0.00 20.3 ---- 0.0 0.00 20.3 150 18 0.874 4.0 ---- 13.0 ---- ---- 0.00 0.00 20.3 ---- 0.00 0.00 20.3 16 17 17.00 BR ---- 13.0 ---- ---- 8.7 0.95 20.3 ---- 8.7 0.95 20.3 150 19 0.874 4.0 ---- 13.0 ---- ---- 0.05 0.00 19.4 ---- 0.05 0.00 19.4 17 19 3.50 B ---- 13.0 ---- ---- 20.0 1.36 19.4 ---- 20.0 1.36 19.4 DATE; 10/31/2018 S:\2017\31586\CALC\3475-ALT.rdf Page 3 150 20 0.874 3.0 ---- 13.0 4.71 20.0 0.21 0.00 18.0 20.0 0.21 0.00 18.0 18 19 23.50 3R ---- 13.0 ---- ---- -11.3 1.92 19.4 ---- -11.3 1.92 19.4 150 21 0.874 3.0 ---- 13.0 ---- ---- -0.07 0.00 21.3 ---- -0.07 0.00 21.3 19 21 2.00 L ---- 13.0 ---- ---- -11.3 0.43 21.3 ---- -11.3 0.43 21.3 150 22 0.874 4.0 ---- 11.0 ---- ---- -0.07 0.87 22.6 ---- -0.07 0.87 22.6 20 22 39.50 LB6R ---- 11.0 ---- ---- -11.3 3.80 22.6 ---- -11.3 3.80 22.6 150 23 0.874 13.0 ---- 11.0 ---- ---- -0.07 0.00 26.4 ---- -0.07 0.00 26.4 21 23 37.50 2LB6R ---- 11.0 ---- ---- -11.3 3.94 26.4 ---- -11.3 3.94 26.4 150 11 0.874 17.0 ---- 11.0 ---- ---- -0.07 0.00 30.3 ---- -0.07 0.00 30.3 Legend: P - Pipe # DIA - Pipe Diameter EQV. LN - Pipe Equivalent Length PUMP - Pump Pressure SP - K-Factor FLOW - Flow Rate PF - Pressure Loss due to Friction PT - Total Pressure at Node Fitting Code Letters: Node Notes Pipe Notes LEN - Pipe Length FIT. - Pipe Fittings FIXD LOSS - Fixed Loss Device EL - Node Elevation DISCH - Discharge in gpm FL/FT - Friction Loss per Foot PE - Pressure Loss due to Elevation E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X, Y= Y, 2 The maximum velocity of water flow occurs in pipe 2 at 18.40 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 2 at 18.40 ft/s with 1 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt PAGE: C MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.874 1.00 4.00 3.00 1.00 1.00' 5.00 2.00 0.00 0.00 0.00 1.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 PAGE: K MATERIAL: Copper Tube-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.745 0.00 1.00 3.00 1.00 1.00 0.00 0.00 0.00 0.00 0.00 0.995 1.00 2.00 6.00 2.00 2.00 6.00 0.00 0.00 0.00 0.00 DATE: 10/31/2018 S:\2017\31586\CALC\3475_ALT.rdf Page 4 PAGE: L MATERIAL: Copper Tube-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.265 1.00 3.00 6.00 2.00 2.00 7.00 0.00 0.00 0.00 0.00 PAGE: P MATERIAL: PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.360 2.00 8.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.8.0 computer program (License No. 50081444 ) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.02 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.19 gpm with 1 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure of 61.7 psi and a 7 minute flow of 175 gal. and a 10 minute flow of 250.0 gallons. The minimum pressure at any node is 18.0 psi at node 20. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 DATE--10/31/2018 S:\2017\31586\CALL\3475_ALT.rdf Page 5 WATER SUPPLY CURVE 75.0- C 1 67.5 P CD 60.0 R E 52.5 S S 45.0 U R 37.5 E 30.0 ( P 22.5 S I 15.0 } 7.5 0.0 04 8 12 16 20 24 28 FLOW (GPM) � I 32 36 40 Static = 74.5 psi, Residual = 67.3 psi @ 2300 gpm (1 sprinkler flowing) (1 sprinklers flowing) A = Available Water Supply C = Available Water Supply 74.5 psi @ 25.0 gpm 74.5 psi @ 25.0 gpm B = Required Water Supply D = Required Water Supply 61.7 psi @ 25.0 gpm 61.7 psi @ 25.0 gpm DATE: 10/31/2018 S:\2017\31586\CALC\3475—ALT.rdf Page 6 City of La Quinta Design and Development Department 0"Krev 78-495 Calle Tampico eca La Quinta, CA 92253 _— C.LAI f,f�'"=Sk:Kt, -- Telephone: (760)777-7125 Fax: (760)777-1233 www.la- uinta.or Riverside County Fire Department Riverside Office 2300 Market Street, Ste.150 lam. Riverside, CA 92501 (951)955-4777 FIRE REVIEW APPLICATION! ❑ NEW 8 TENANT IMPROVEMENT FC M PU18- 0005 PERMIT NO. 1=SS-2017-0041 PROJECT INFORMATION (Please Print) Project Name: GRIFFIN RANCH / TRACT 32879 / PLAN TYPE 3 Sign: Site Address: MASTER PLAN 3 (AS -BUILT) Print: JAM B HI City & Zip: LA QUINTA, CA 92253 Pursuant to a Cooperative Agreement to Provide Fire Services, the Riverside County Fire Department serves as the City's fire department, and the County designee serves as the City's fire chief. Applicant recognizes this contracted arranciement and shall comply with Counfy Fire Department diractlons, APPLICANT/CONTACT INFORMATION CONTRACTOR INFORMATION: B Same as Applicant info Applicant Name: FIRE SPRINKLER SYSTEMS Contractor#: 684600 Contact Person: JAM I E B I S H I P Mailing Address: 705 HARRISON ST. # 200 City & Zip: CORONA, CA 92879 Phone Number: 951-272-2522 Fax: Email: Contact Person: JAM I E B I S H I P Mailing Address: 705 E. HARRISON ST. #200 City & Zip: CORONA, CA 92879 Phone Number: 951-272-2522 Fax: Email: A. APPLICATION TYPE FIRE SPRINKLER SYSTEM SUPRESSION SYSTEM ❑ NEW COMMERCIAL/INDUSTRIAL _ ❑ HOOD & DUCT $405 ❑ 0-35,000 SQ FT $639 ❑ SPRAY BOOTH $795 ❑ 35,001-75,000 SQ FT $756 ❑ CELL SITE $795 ❑ 75,001-120,000 SQ FT $951 ❑ OTHER SUPRESSION SYSTEM $795 ❑ 120,001 AND UP $1185 MISC ❑ TI COMMERCIAL/INDUSTRIAL $405 ❑ HAZMAT $327 G RESIDENTIAL -1 DWELLING UNIT $405 ❑ HIGH PILE RACK STORAGE $327 CI RESIDENTIAL - (EA) ADDITIONAL x $171 ❑ NEW COMMERCIAL - U/G WATER $483 0 MULTI -FAMILY (3 OR MORE) $561 ❑ FIRE FLOW REPORT $327 FIRE ALARM SYSTEM ❑ TECHNICAL REPORT RESEARCH HOURLY @ $156/HR ❑ COMMERCIAL- SPRINKLER MONITORING $405 ❑ SPECIAL INSPECTION $161 ❑ COMMERCIAL- FIRE ALARM SYSTEM $1092 ❑ FIRE PUMPS $639 FIRE ALARM SYSTEM ❑ STANDPIPE SYSTEMS $561 ❑ COMMERCIAL - SPRINKLER MONITORING $405 ❑ WATER TANKS $390 ❑ COMMERCIAL - FIRE ALARM SYSTEM $1092 STORAGE TANKS ❑ DISPENSERS ONLY HOURLY @ $156/HR ❑ ABOVE GROUND HOURLY @ $156/HR racn app icaaon type incwaes a i ecnnotogy tnnancement Fee5S & Recoras Management Fee 510 Bill # City of La Quinta Building SL Safety Division Permit # P.O. Box 1504, 78-495 Cafie Tampico La.Quinta, CA 92253 - (760) 777 7a12 Building Permit Application and Tracking Sheet ProjectAddt'ess: MASTER PLAN 3 (AS -BUILT TO FSS-201.7-0041) Owner's Name: LENNAR A.P. Number. Address:980 MONTECITO DR. # 302 Legal Description: MASTER PLAN TYPE 3• . • City, ST, Zip: CORONA, CA 92879 Contractor. FIRE SPRINKLER SYSTEMS, INC Telephone: Address: 705 E. HARRISON ST. #200 Project Description. City, ST, Zip: CORONA, CA 92879 INSTALLATION OF RESIDENTIAL FIRE SPRINKLERS Telephone: 951-272-2522 36 HEADS / 4,120 SF State Lie. # : 684600 City Lie. #; 762890 Arch., Enpr., Designer. Address: City, ST, Zip: Telephone: Construction Type:.V-B Occupancy: R3/U State Lie. #: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: JAMIE BISHIP Sq. Ft.: 4,120 SF # Stories: 1 #Unit$: N/A Telephone # of Contact Pelson: 951-272-2522 Estimated Value of Project: $2.110.00 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Reed TEACHING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural CAIcs. Reviewed, ready for corrections Plan Check Deposit Truss Coles. Called Contact Person Plan Check Balance Title 24 Cales. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2•t Review, ready for correctionsfissue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for correctionsfissue Developer Impact Fee Planning Approval Called Contact Person Ayp,p_ Pub. Wks. Appr Date of permit Issue School Fees Total Permit Fees