Loading...
FSS2017-0042 Griffin Ranch Plan 4 Rev 2Description: GRIFFIN RANCH / MASTER FIRE SPRINKLER / PLAN 3818 / TR 32879 Type: FIRE SPRINKLER Subtype: RESIDENTIAL -TRACT Status: FINALED Applied: 9/14/2017 AMA HOMES Approved: 9/19/2017 RGR Parcel No: 767780085 Site Address: 81181 MERV GRIFFIN WY LA QUINTA,CA 92253 Subdivision: TR 32879 Block: Lot: AW Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 2/6/2018 RGR Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 7CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES DEPOSIT REFUNDED. 101-0000-22811 CLOSED. COUNCIL DEPOSIT MIRTA LERMA 8/13/2018 8/13/2018 APPROVED A FLAT FEE STRUCTURE FOR FIRE INSPECTION AUGUST 2017. AL ML CONDITIONS CONTAC NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST CORONA CA 92879 (800)915-3473 JUDYL@FIREINC.NET SUITE 200 BILL TO FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST CORONA CA 92879 (800)915-3473 JUDYL@FIREINC.NET SUITE 200 CONTRACTOR FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST CORONA CA 92879 (800)915-3473 JUDYL@FIREINC.NET SUITE 200 Printed: Thursday, January 26, 2023 3:27:00 PM 1 of 3 WsYsrEMS 1 INFORMATION FINANCIAL CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY FIRE SPRINKLER SYSTEM RESIDENTIAL - 101-0000-22811 1 $614.00 $614.00 9/14/17 R27960 229262 CHECK FIRE SPRINKLER AMA SYSTEMS INC MODELS Total Paid for FIRE SPRINKLER SYSTEM RESIDENTIAL - $614.00 $614.00 MODELS: TECHNOLOGY 502-0000-43611 0 $5.00 $5.00 9/14/17 R27960 229262 CHECK FIRE SPRINKLER AMA ENHANCEMENT FEE SYSTEMS INC Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 • 00 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES DATE DATE OVERHEAD HYRO RGR 11/3/2017 11/3/2017 DISAPPROVE Relocate entry way sprinkler repair hangers OVERHEAD ROUGH RGR 11/14/2017 11/14/2017 APPROVED PIPING FIRE FINAL" RGR 2/6/2018 2/6/2018 APPROVED PARENT PROJECT��� PROJECT NO PROJECTTYPE APPLIED PROJECTSUETYPE APPROVED STATUS CLOSED PLANNER BTCP2017-0006 TRACT RESIDENTIAL 6/9/2017 STANDARD 8/28/2017 APPROVED- JAKE FUSON CONSTRUCTION PLAN CONDITIONS Printed: Thursday, January 26, 2023 3:27:00 PM 2of3 CRWSYSTEMS BOND INFORMATION Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED Building Permit Building Permit DOC 11/4/2021 JOSE DELGADO Application and Application & Tracking 0 Tracking Sheet.pdf Sheet.pdf DOC 11/4/2021 JOSE DELGADO Fire Review Fire Review 0 Application.pdf Application.pdf Printed: Thursday, January 26, 2023 3:27:00 PM 3 of 3 WsYsrEMS ---- ---------------------------------------------------------------------------------_-_--~ ............. ' _--�_....................... - -----------_�-_— / ' J Fire Flow Analysis ! | hydrant ' ) ' | ' | � � | | ' ' | / ) � , / ) / ! | | \ ` / / | z / . i [ / ` . | / T ` . � / . ' � . | - / ' ' -i [ -------- --- � --^ � NN 3. .~.� °^ ^-----------------------------------------------------------------------.- ---- --- "" ---~° - . 4 MADP50HS111EE1 .v.3oT _ 1Un S N m s CANAliERO P1C1E ilk 3 3EF mo OiRCLE ANy SEC Rk74 ve A}LINML11 Ca11F1 INOl4? r N C p N Y W N O lM1Rnv�xSAS�E O 1M111LO d43µ4F A O y P V f 0�3 liQ 3 c I' N „ O yy N b N � � V V H P A f O m T ^ ' 1 A N ;=•-�= N fn N N w a w w O 0 O OOOOOO;o'! Z W OONOp OOp�� L^ G_ e _ Na °s z WIG LR7Sv'N'1 N. $ N �' n N a v m A o T pm r z y��y� m, "D O a �.�}pv71YAv9 N J m Z Z a p Z O N V W N N P O W A a y N W pr_101 m a` N %4 N BMW � V m MENV GtIEAN WAT El0}M 6 SdiKu� T W N 3A4N0 > P W I N O O N 'w � � �_ AARR 3iFR ORLYE � MADAGA3OAN WAY LOT'Al Gp �- w WELL SIZE ' ^� CRIrE AR0F17NFG PEIYE .. — _ � LOT' MSA CONSULTING, INC PIAleam ■ Cmm 43� . wm---VHLv.r MM Bm Hove Dues • RAP®o Hum. CA M70 7Mmumm (760) 330-son w F.%x (76o) 3237m 0..r 0620 2017 CONSTRUCTION PHASING EXHIBIT GRIFFIN RANCH - LENNAFt DATE: 8/29/2017 S:\2017\31586\CALC\3818.rdf Page 1 FIRE SPRINKLER SYSTEMS 705 E. HARRISON, SUITE 200 CORONA,CA 92879 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR GRIFFIN RANCH LA QUINTA, CA PLAN 3818 10% TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN CALC AREA 1 Date: 8/29/2017 File No: 31586 Data File Name: 3818.rdf SPRINKLER SPACING 256.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 16.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 8.0 ft. SPRINKLER SPECIFICATIONS Mfr: Reliable Descr: RA0616 RFC49 F1 Conc .Pend.(16xl6) K=4.90 Calculated K Factor for Arm-Overs & Drops: 1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee) 0.0 ft. x 0.874 in. Arm -Over: K=4.67 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 74.5 psi Resid: 67.3 psi F1ow:2300.0 gpm Public Main Size: 8 in Domestic Demand: 5.0 gpm at node number 104 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press Flowing Flow (psi) 1 13.0 7.6 2 13.0 7.6 REVIEWING AUTHORITY CITY OF LA QUINTA FIRE DEPT. Node Total Avail. Req'd No. Flow Press. Press. 14 18.0 74.5 30.7 14 31.5 74.5 52.2 DATE: 8/29/2017 S:\2017\31586\CALC\3818.rdf Page 2 RESULTS OF ANALYSIS PIPE & NODE DATA * FLOW ANALYSIS * 1 sprinkler flowing * 2 sprinklers flowing FIXD P # END LEN FIT. LOSS EL SP *DISCH FLOW PF PT *DISCH FLOW PF PT HWC NOD DIA EQV.LN PUMP (FT) (K) *(GPM) FL/FT PE (PSI)*(GPM) FL/FT PE (PSI) 1 100 30.00 BG ---- -2.0 SRCE ---- 18.0 3.30 30.7 ---- 31.5 9.28 52.2 150 101 0.995 6.0 ---- -2.0 ---- ---- 0.09 0.00 27.4 ---- 0.26 0.00 42.9 2 101 1.00 -4.0 -2.0 ---- ---- 18.0 0.09 27.4 ---- 31.5 0.26 42.9 150 102 0.995 0.0 ---- -2.0 ---- ---- 0.09 0.00 23.3 ---- 0.26 0.00 38.7 3 102 70.00 3L - - -2.0 ---- ---- 18.0 1.88 23.3 ---- 31.5 5.30 38.7 150 103 1.360 24.0 ---- -2.0 ---- ---- 0.02 0.00 21.4 ---- 0.06 0.00 33.4 4 103 4.00 LG ---- -2.0 ----- ---- 18.0 0.20 21.4 ---- 31.5 0.56 33.4 150 104 1.265 3.0 ---- 2.0 -5 5 0.03 1.73 19.5 5 0.08 1.73 31.1 5 104 2.00 L ---- 2.0 -5 5 13.0 0.21 19.5 5 26.5 0.80 31.1 150 105 1.101 5.0 ---- 4.0 ---- ---- 0.03 0.87 18.4 ---- 0.11 0.87 29.4 6 105 1.00 -3.0 4.0 ---- ---- 13.0 0.03 18.4 ---- 26.5 0.11 29.4 150 106 1.101 0.0 ---- 4.0 ---•- ---- 0.03 0.00 15.4 ---- 0.11 0.00 26.3 7 106 7.00 2L ---- 4.0 ---- ---- 13.0 0.52 15.4 ---- 26.5 1.95 26.3 150 10 1.101 10.0 ---- 11.0 ---- ---- 0.03 3.03 11.8 ---- 0.11 3.03 21.3 8 10 6.50 L ---- 11.0 ---- ---- 13.0 0.99 11.8 ---- 26.5 3.70 21.3 150 11 0.874 4.0 ---- 11.0 ---- ---- 0.09 0.00 10.8 ---- 0.35 0.00 17.6 9 11 50.00 B7R - - 11.0 ---- ---- 7.0 1.79 10.8 ---- 14.0 6.48 17.6 150 12 0.874 10.0 --- 11.0 ---- ---- 0.03 0.00 9.0 ---- 0.11 0.00 11.1 10 12 24.00 3R ---- 11.0 ---- •----- 7.0 0.81 9.0 ---- 14.0 2.92 11.1 150 13 0.874 3.0 ---- 11.0 ---- ---- 0.03 0.00 8.2 ---- 0.11 0.00 8.2 11 13 3.50 B ---- 11.0 ---- ---- 13.0 0.61 8.2 ---- 13.0 0.61 8.2 150 14 0.874 3.0 ---- 11.0 4.71 13.0 0.09 0.00 7.6 13.0 0.09 0.00 7.6 12 13 5.00 B -- - 11.0 ---- ---- -6.0 0.18 8.2 ---- 1.0 0.01 8.2 150 15 0.874 3.0 ---- 11.0 4.71 ---- -0.02 0.00 8.4 13.5 0.00 0.00 8.2 13 15 18.50 2R ---- 11.0 4.71 ---- -6.0 0.46 8.4 13.5 -12.5 1.81 8.2 150 16 0.874 2.0 ---- 11.0 ---- ---- -0.02 0.00 8.9 ---- -0.09 0.00 10.0 14 16 14.00 2R ---- 11.0 ---- ---- -2.7 0.08 8.9 ---- -5.6 0.32 10.0 150 17 0.874 2.0 ---- 11.0 ---- ---- -0.01 0.00 8.9 ---- -0.02 0.00 10.3 15 17 6.50 R ---- 11.0 ---- --•-- -2.7 0.04 8.9 -- - -5.6 0.15 10.3 150 18 0.874 1.0 ---- 11.0 ---- ---- -0.01 0.00 9.0 -- -0.02 0.00 10.5 16 18 5.00 B ---- 11.0 ---- ---- -2.7 0.04 9.0 ---- -5.6 0.16 10.5 150 19 0.874 3.0 ---- 11.0 ---- ---- -0.01 0.00 9.0 ---- -0.02 0.00 10.6 17 19 2.00 L ---- 11.0 ---- ---- -2.7 0.03 9.0 -- - -5.6 0.12 10.6 DATE: 8/29/2017 S:\2017\31586\CALC\3818.rdf Page 3 150 20 0.874 4.0 ---- 13.0 ---- ---- -0.01 0.87 8.2 ---- -0.02 0.87 9.9 18 20 56.00 L5R ---- 13.0 ---- ---- -2.7 0.33 8.2 ---- -5.6 1.30 9.9 150 21 0.874 9.0 ---- 13.0 ---- ---- -0.01 0.00 8.5 ---- -0.02 0.00 11.2 19 21 14.00 B3R ---- 13.0 ---- ---- -2.7 0.10 8.5 ---- -5.6 0.40 11.2 150 22 0.874 6.0 ---- 13.0 ---- ---- -0.01 0.00 8.6 ---- -0.02 0.00 11.6 20 22 56.00 B6R ---- 13.0 ---- ---- 3.3 0.49 8.6 ---- 6.9 1.90 11.6 150 23 0.874 9.0 ---- 13.0 ---- ---- 0.01 0.00 8.1 ---- 0.03 0.00 9.7 21 23 2.00 L ---- 13.0 ---- ---- 3.3 0.05 8.1 ---- 6.9 0.18 9.7 150 24 0.874 4.0 ---- 11.0 ---- ---- 0.01 0.87 9.0 ---- 0.03 0.87 10.4 22 24 5.50 LB ---- 11.0 ---- ---- 3.3 0.09 9.0 ---- 6.9 0.37 10.4 150 16 0.874 7.0 ---- 11.0 ---- ---- 0.01 0.00 8.9 ---- 0.03 0.00 10.0 23 22 8.00 2R ---- 13.0 ---- ---- -6.0 0.23 8.6 ---- -12.5 0.88 11.6 150 25 0.874 2.0 ---- 13.0 ---- ---- -0.02 0.00 8.9 ---- -0.09 0.00 12.5 24 25 2.00 L ---- 13.0 ---- ---- -6.0 0.14 8.9 ---- -12.5 0.53 12.5 150 26 0.874 4.0 ---- 11.0 ---- ---- -0.02 0.87 9.9 ---- -0.09 0.87 13.9 25 26 27.50 2L2BR ---- 11.0 ---- ---- -6.0 0.96 9.9 ---- -12.5 3.74 13.9 150 11 0.874 15.0 ---- 11.0 ---- ---- -0.02 0.00 10.8 ---- -0.09 0.00 17.6 Node Notes Pipe Notes Legend: P - Pipe # LEN - Pipe Length DIA - Pipe Diameter FIT. - Pipe Fittings EQV. LN - Pipe Equivalent Length FIXD LOSS - Fixed Loss Device PUMP - Pump Pressure EL - Node Elevation SP - K-Factor DISCH - Discharge in gpm FLOW - Flow Rate FL/FT - Friction Loss per Foot PF - Pressure Loss due to Friction PE - Pressure Loss due to Elevation PT - Total Pressure at Node Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X, Y= Y, Z= The maximum velocity of water flow occurs in pipe 1 at 7.43 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 8 at 14.17 ft/s with 2 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt DATE: 8/29/2017 S:\2017\31586\CALC\3818.rdf Page 4 PAGE: C MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.874 1.00 4.00 3.00 1.00 1.00 5.00 2.00 0.00 0.00 0.00 1.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 PAGE: K MATERIAL: Copper Tube-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.995 1.00 2.00 6.00 2.00 2.00 6.00 0.00 0.00 0.00 0.00 PAGE: L MATERIAL: Copper Tube-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.265 1.00 3.00 6.00 2.00 2.00 7.00 0.00 0.00 0.00 0.00 PAGE: P MATERIAL: PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.360 2.00 8.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.7.0 computer program (License No. 50081444 ) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.01 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.07 gpm with 2 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure of 52.2 psi and a 7 minute flow of 221 gal. and a 10 minute flow of 315.1 gallons. The minimum pressure at any node is 7.6 psi at node 14. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 DATE: 8/29/2017 S:\2017\31586\CALC\3818.rdf Page 5 LA ^'L== �Y Q T VE 75.E I 67.5 p I R60.0 S52.5 D S I U45.0 R E37.5 c (30.0 B p I 522.5 I I ) 15.0 7.5 0 - �4 8 12 16 20 24 28 32 36 40 FLOW (GPM) = 74.5 psi, Re5luuai = oi.3 psi @ 2300 qpm r flowinq) (2 sprinklers flowing) = Available WatC = Available water Supply 74.5 psi @ 18.0 c74.5 psi @ 31.5 qpm = Required WateD = Required Water Supply 30.7 psi @ 18.0 c52.2 psi @ 31.5 gpm DATE: 8/29/2017 S:\2017\31586\CALC\3818.rdf Page 6 DATE: 8/29/2017 S:\2017\31586\CALC\3818.rdf Page 1 FIRE SPRINKLER SYSTEMS 705 E. HARRISON, SUITE 200 CORONA,CA 92879 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR GRIFFIN RANCH LA QUINTA, CA PLAN 3818 10t TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN CALL AREA 2 Date: 8/29/2017 File No: 31586 Data File Name: 3818.rdf SPRINKLER SPACING 400.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 20.0 ft. Min. Dist. Bet. Spklrs: 10.0 Max. Dist. Spklr. to Wall: 10.0 ft. SPRINKLER SPECIFICATIONS Mfr: Reliable Descr: RA0616 RFC49 F1 Conc .Pend.(20x20) K=4.90 Calculated K Factor for Arm-Overs & Drops: 1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee) 0.0 ft. x 0.874 in. Arm -Over: K=4.67 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 74.5 psi Resid: 67.3 psi F1ow:2300.0 gpm Public Main Size: 8 in Domestic Demand: 5.0 gpm at node number 104 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press. Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 20.0 18.0 18 25.0 74.5 51.9 1 20.0 18.0 18 25.0 74.5 51.9 REVIEWING AUTHORITY CITY OF LA QUINTA FIRE DEPT. DATE: 8/29/2017 S:\2017\31586\CALC\3818.rdf Page 2 RESULTS OF ANALYSIS PIPE & NODE DATA * FLOW ANALYSIS * 1 sprinkler flowing * 1 sprinklers flowing FIXD P # END LEN FIT. LOSS EL SP *DISCH FLOW PF PT *DISCH FLOW PF PT HWC NOD DIA EQV.LN PUMP (FT) (K) *(GPM) FL/FT PE (PSI)*(GPM) FL/FT PE (PSI) 1 100 30.00 BG ---- -2.0 SRCE ---- 25.0 6.05 51.9 ---- 25.0 6.06 51.9 150 101 0.995 6.0 ---- -2.0 ---- ---- 0.17 0.00 45.9 ---- 0.17 0.00 45.9 2 101 1.00 -4.0 -2.0 ---- ---- 25.0 0.17 45.9 ---- 25.0 0.17 45.9 150 102 0.995 0.0 ---- -2.0 ---- ---- 0.17 0.00 41.7 ---- 0.17 0.00 41.7 3 102 70.00 3L ---- -2.0 ---- ---- 25.0 3.45 41.7 ---- 25.0 3.45 41.7 150 103 1.360 24.0 ---- -2.0 ---- ---- 0.04 0.00 38.3 ---- 0.04 0.00 38.3 4 103 4.00 LG ---- -2.0 ---- ---- 25.0 0.37 38.3 ---- 25.0 0.37 38.3 150 104 1.265 3.0 •---- 2.0 -5 5 0.05 1.73 36.2 5 0.05 1.73 36.2 5 104 2.00 L ---- 2.0 -5 5 20.0 0.48 36.2 5 20.0 0.48 36.2 150 105 1.101 5.0 ---- 4.0 ---- ---- 0.07 0.87 34.8 ---- 0.07 0.87 34.8 6 105 1.00 -3.0 4.0 ---- ---- 20.0 0.07 34.8 ---- 20.0 0.07 34.8 150 106 1.101 0.0 ---- 4.0 ---- ---- 0.07 0.00 31.8 ---- 0.07 0.00 31.8 7 106 7.00 2L ---- 4.0 ---- ----- 20.0 1.16 31.8 ---- 20.0 1.16 31.8 150 10 1.101 10.0 - -- 11.0 ---- ---- 0.07 3.03 27.6 ---- 0.07 3.03 27.6 8 10 6.50 L ---- 11.0 - -- ---- 20.0 2.20 27.6 ---- 20.0 2.20 27.6 150 11 0.874 4.0 ---- 11.0 ---- ---- 0.21 0.00 25.4 ---- 0.21 0.00 25.4 9 11 50.00 B7R ---- 11.0 ---- ---- 8.7 2.70 25.4 ---- 8.7 2.70 25.4 150 12 0.874 10.0 ---- 11.0 ---- ---- 0.04 0.00 22.7 ---- 0.04 0.00 22.7 10 12 24.00 3R ---- 11.0 ---- --•-- 8.7 1.21 22.7 ---- 8.7 1.21 22.7 150 13 0.874 3.0 ----- 11.0 ---- ---- 0.04 0.00 21.4 ---- 0.04 0.00 21.5 11 13 3.50 B ---- 11.0 ---- ---- 0.0 0.00 21.4 ---- 0.0 0.00 21.5 150 14 0.874 3.0 ---- 11.0 ---- ---- 0.00 0.00 21.4 ---- 0.00 0.00 21.5 12 13 5.00 B ---- 11.0 ---- ---- 8.7 0.36 21.4 ---- 8.7 0.36 21.5 150 15 0.874 3.0 ---- 11.0 ---- ••--- 0.04 0.00 21.1 ---- 0.04 0.00 21.1 13 15 18.50 2R ---- 11.0 ---- ---- 8.7 0.92 21.1 ---- 8.7 0.92 21.1 150 16 0.874 2.0 ---- 11.0 ---- ---- 0.04 0.00 20.2 ---- 0.04 0.00 20.2 14 16 14.00 2R ---- 11.0 ---- ---- 12.8 1.47 20.2 ---- 12.8 1.47 20.2 150 17 0.874 2.0 ---- 11.0 ---- ---- 0.09 0.00 18.7 •---- 0.09 0.00 18.7 15 17 6.50 R ---- 11.0 ---- ---- 12.8 0.69 18.7 ---- 12.8 0.69 18.7 150 18 0.874 1.0 ---- 11.0 4.71 20.0 0.09 0.00 18.0 20.0 0.09 0.00 18.0 16 18 5.00 B - -- 11.0 4.71 20.0 -7.2 0.25 18.0 20.0 -7.2 0.25 18.0 150 19 0.874 3.0 ---- 11.0 ---- ---- -0.03 0.00 18.3 ---- -0.03 0.00 18.3 17 19 2.00 L ---- 11.0 ---- ---- -7.2 0.19 18.3 ---•- -7.2 0.19 18.3 DATE: 8/29/2017 S:\2017\31586\CALL\3818.rdf Page 3 150 20 0.874 4.0 ---- 13.0 ---- ---- -0.03 0.87 17.6 ---- -0.03 0.87 17.6 18 20 56.00 L5R ---- 13.0 ---- ---- -7.2 2.04 17.6 ---- -7.2 2.04 17.6 150 21 0.874 9.0 ---- 13.0 ---- ---- -0.03 0.00 19.6 ---- -0.03 0.00 19.6 19 21 14.00 B3R ---- 13.0 ---- ---- -7.2 0.63 19.6 ---- -7.2 0.63 19.6 150 22 0.874 6.0 ---- 13.0 ---- ---- -0.03 0.00 20.2 ---- -0.03 0.00 20.2 20 22 56.00 B6R ---- 13.0 ---- ---- 4.1 0.73 20.2 ---- 4.1 0.73 20.2 150 23 0.874 9.0 ---- 13.0 ---- ---- 0.01 0.00 19.5 ---- 0.01 0.00 19.5 21 23 2.00 L ---- 13.0 ---- ---- 4.1 0.07 19.5 ---- 4.1 0.07 19.5 150 24 0.874 4.0 ---- 11.0 _- - ---- 0.01 0.87 20.3 ---- 0.01 0.87 20.3 22 24 5.50 LB ---- 11.0 ---- ---- 4.1 0.14 20.3 ---- 4.1 0.14 20.3 150 16 0.874 7.0 ---- 11.0 ---- ---- 0.01 0.00 20.2 ---- 0.01 0.00 20.2 23 22 8.00 2R ---- 13.0 ---- ---- -11.3 0.73 20.2 ---- -11.3 0.73 20.2 150 25 0.874 2.0 ---- 13.0 ---- ---- -0.07 0.00 21.0 ---- -0.07 0.00 21.0 24 25 2.00 L ---- 13.0 ---- ---- -11.3 0.44 21.0 ---- -11.3 0.44 21.0 150 26 0.874 4.0 ---- 11.0 -0.07 0.87 22.3 ---- -0.07 0.87 22.3 25 26 27.50 2L2BR ---- 11.0 ---- ---- -11.3 3.09 22.3 ---- -11.3 3.09 22.3 150 11 0.874 15.0 ---- 11.0 ---- ---- -0.07 0.00 25.4 ---- -0.07 0.00 25.4 Node Notes Pipe Notes Legend: P - Pipe # LEN - Pipe Length DIA - Pipe Diameter FIT. - Pipe Fittings EQV. LN - Pipe Equivalent Length FIXD LOSS - Fixed Loss Device PUMP - Pump Pressure EL - Node Elevation SP - K-Factor DISCH - Discharge in gpm FLOW - Flow Rate FL/FT - Friction Loss per Foot PF - Pressure Loss due to Friction PE - Pressure Loss due to Elevation PT - Total Pressure at Node Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X, Y= Y, Z The maximum velocity of water flow occurs in pipe 8 at 10.70 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 8 at 10.70 ft/s with 1 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt •DATE: 8/29/2017 S:\2017\31586\CALC\3818.rdf Page 4 PAGE: C MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.874 1.00 4.00 3.00 1.00 1.00 5.00 2.00 0.00 0.00 0.00 1.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 PAGE: K MATERIAL: Copper Tube-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.995 1.00 2.00 6.00 2.00 2.00 6.00 0.00 0.00 0.00 0.00 PAGE: L MATERIAL: Copper Tube-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.265 1.00 3.00 6.00 2.00 2.00 7.00 0.00 0.00 0.00 0.00 PAGE: P MATERIAL: PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.360 2.00 8.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.7.0 computer program (License No. 50081444 ) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.09 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.02 gpm with 1 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure of 51.9 psi and a 7 minute flow of 175 gal. and a 10 minute flow of 250.0 gallons. The minimum pressure at any node is 17.6 psi at node 20. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 DATE: 8/29/2017 S:\2017\31586\CALL\3818.rdf Page 5 WATER SUPPLY CURVE 75.0 C 67.5 P 60.0 R E .5 S 52 S 45.0 U R 37.5 E { 30.0 P 22.5 S I 15.0 l 7.5 0.0 04 8 12 16 20 24 28 32 36 FLOW (GPM) Static = 74.5 psi, Residual = 67.3 psi @ 2300 gpm (1 sprinkler flowing) (1 sprinklers flowing) A = Available Water Supply C = Available Water Supply 74.5 psi @ 25.0 gpm 74.5 psi @ 25.0 gpm B = Required Water Supply D = Required Water Supply 51.9 psi @ 25.0 gpm 51.9 psi @ 25.0 gpm 40 DATE: 8/29/2017 S:\2017\31586\CALC\3818.rdf Page 6 W.Alrep . a. Domestic Water System Flow Analysis Domestic Water S.ystern Flow'Analysis (Hydraulic Model) Requested By: FIRE SPRINKLERS SYSTEMS, INC. Address: 705 E. HARRISON STREET CORONA, CA 92879 Contact Name: JAMIE BISHIP Phone: 800-915-3473 Coachella Valley Water District 75515 Hovley Lane East Palm Desert, CA 92211 Date: 1 7/18/17 APN: Req. Fire Flow: 100091)m at 20psi fort hours. Project Name: I GRIFFIN RANCH Email: jamieb@fireinc.net Cell:' Domestic Water System HYDRANT AT THE NE CORNER OF MERV GRIFFIN WAY AND DAMASCUS DRIVE, La Quinta, GEO Flow Analysis Location: 6-7-15-2, PZ 17-8160 Flow Analysis Description Test 1 Elevation (Ft): -16 Steady State, Dynamic (psl): 82.8 Residual Pressure (psi): 74.82 Fire Flow Tested (gpm): 2,300 Combined Total: Tested Model Junction: I J1828 Model Information stic Water Hydraulic Model Results Requested • Test 2 Test 3 Test 4 Flow _ Domestic system flow None available without exceeding N/A CVWD's N/A criteria. Duration: 1 2 hours - Demand Conditions: Peak Day Demand (PDD) Reservoir No./Level (s): Reservoir 6726 Pumps Operating No's: Pumps On Pressure Zone and HGL: Lake Cahuilla (145') Model: MervGriffin&Damascus-CVWD DomesticWater 012616 Comments: The domestic water system is capable of providing 2,300 gpm for 2 hours that satisfies CVWD's minimum pressure, velocity, and/or head loss criteria. This flow can be achieved by using multiple fire hydrants. This simulated system flow analysis may not include all facilities that may be required for this development/project. Please check with Development Services for further information on all required facilities: The theoretical flow to drop the residual pressure to 20 psi is greater than 5,000 gpm. Please note the theoretical flow exceeds CVWD's design criteria on the domestic water network. These results are based on hydraulic modelling and not a guarantee that CVWD's domestic water system will have the capacity to supply water to the project at the flows or pressures indicated. It is important to note that the capacity of the on -site fire system, meters, service lines, backflow assemblies and other appurtenances were not considered in this analysis, which may alter actual flows or pressures. Due to continuous changes in the system, CVWD only considers this system flow analysis valid for six months from date of modelling/analysis. These system flow analysis comments are for plan check purposes only. The ultimate design responsibility resides with the Engineer -of -Record for this Project. Should you have any questions or need additional information, please conta t J 3g866 xt. 2397. l �. , , x ;A B.� . ' A,UG U 2011 Completed By: �~ �I''�}' ,,, '(JIN'7; Date 1.7 _ OPMENT Page 1 of 1 ENG DS-016 01_11_3� (8/31/15) City of La Qu i nta Design and Development Department waT`iT 78-495 Cane Tampico Lo Quinta, CA 92253 Telephone: (760)777-7125 Fax: (760)777-1233 www.lo-quinta.org Riverside County Fire Department Riverside Office 2300 Market Street, Ste. 150 Riverside, CA 92501 (951)955-4777 FIRE REVIEW APPLICATION ❑ NEW Ip TENANT IMPROVEMENT PROJECT INFORMATION t STAMP PERMIT NO. FSS-2017-0042 Please Print Protect Dame: GRIFFIN RANCH / TRACT 32879 / PLAN TYPE 4 Sign: Site Address: MASTER PLAN 4 (AS -BUILT) Print: 'JA IS IP City & Zip: LA QUINTA, CA 92253 Pursuant to a Cooperative Agreement to Provide Fire Services. the Riverside County Fire Department serves as the City's fire department, and the County designee serves as the City's fire chief- Applicant recognizes this contracted arrangement and shall comply with County Fire De0ortment directions. APPLICANT/CONTACT INFORMATION CONTRACTOR INFORMATION: R Same as AppliCant info j AppliicantNome: FIRE SPRINKLER SYSTEMS Contractor#: 684600 Contact Person: JAMIE BISHIP ContoctPerson: JAMIE BISHIP Mailing Address: 705 HARRISON ST. # 200 Mailing Address: 705 E. HARRISON ST. #200 City a, rp: CORONA, CA 92879 City & zip: CORONA, CA 92879 Phone Number: 951-272-2522 Fax: Phone Number: 951-272-2522 Fax: Emoil: Emoil: A. APPLICATION TYPE FIRE SPRINKLER SYSTEM SUPRESSIQN SYSTEM ❑ NEW COMMERCIAL/INDUSTRIAL ------------ ❑ HOOD & DUCT $405 ❑ 0-35,000 SQ FT $639 ❑ SPRAY BOOTH $795 ❑ 35,001-75,000 SQ FT $756 ❑ CELL SITE $795 ❑ 75,001-120,000 SQ FT $951 ❑ OTHER SUPRESSION SYSTEM $795 ❑ 120,001 AND UP $1185 MISC ❑ TI COMMERCIAL/INDUSTRIAL $405 ❑ HAZMAT $327 13 RESIDENTIAL - 1 DWELLING UNIT $4Q5 ❑ HIGH PILE RACK STORAGE $327 ❑ RESIDENTIAL - (EA) ADDITIONAL x $171 ❑ NEW COMMERCIAL - U/G WATER $483 ❑ MULTI -FAMILY (3 OR MORE) $561 ❑ FIRE FLOW REPORT $327 FIRE ALARM SYSTEM ❑ TLCHNICAL REPORT RESEARCH HOURLY @ 5156/1-IR ❑ COMMERCIAL - SPRINKLER MONITORING $405 ❑ SPECIAL INSPECTION $161 ❑ COMMERCIAL - FIRE ALARM SYSTEM $1092 ❑ FIRE PUMPS $639 FIRE ALARM SYSTEM ❑ STANDPIPE S - ti ~- 1 ❑ COMMERCIAL - SPRINKLER MONITORING $405 ❑ WATER TANK 0 ❑ COMMERCIAL -FIRE ALARM SYSTEM $1092 STORAGE TANKS ❑ DISPENSERS ONLY HOURLY @ S156/1-1R Nov 2018 ❑ ABOVE GROUND HOURLY @ $156/HR tGcn application type includes a Technology Enhancement Fee55 & Records Management Fee $14 COMMUNITY DEVELOPMENT City of La Quinta Design and Development Department 78-495 Calle Tampico - La Quinta, CA 92253 Telephone: (760)777-7125 Fax: (760)777-1233 ,rr�r tut www,1...�1J"r4 9C9 Riverside County Fire Department Riverside Office 2300 Market Street, Ste. 150 Riverside, CA 92501 (951)955-4777 FIRE REVIEW APPLICATION 0 NEW ❑ TENANT IMPROVEMENT PERMIT NO. j -1 m t, PROJECT INFORMATION (Please P(nt) Project Name: GRIFFIN RANCH Sign: Site Address: MASTER PLAN TYPE (4) 3818 Print: JAMI ISHIP City & Zip: LA QUINTA, CA I have read and understand that tees are DEPOSIT BASED FEES and there may be additional money due prior to or otter project final. Pursuant to a Cooperative Agreement to Provide fire Services, the Riverside County Fire Department serves as the City`s fire department, and the County designee serves as the City's fire chief. Applicant recognizes this contracted arrangement and shall comply with County Fire Department directions. APPLICANT/CONTACT INFORMATION BILLING INFORMATION: 0 Some as Applicant info Applicant Name: Contractor FIRE SPRINKLER SYSTEMS, INC. License Number: 684600 Contact Person: JAMIE BISHIP Bill To: FIRE SPRINKLER SYSTEMS, INC Mailing Address: 705 E. HARRISON ST. Mailing Address: 705 E. HARRISON ST. #200 City & Zip: CORONA, CA 92879 City & Zip: CORONA, CA 92879 Phone Number: 951-272-2522 Fax: Phone Number: 800-915-3473 Fax: Email: jamieb@fireinc.net Email: jamieb@fireinc.net The pmson listed on "Billing information" will receive Ail billing, correspondence and retunds for any work. billed to this permit. Any chancres in h111in❑ antormatinn mast hp mnri in wrifinrr fn n€ir iH rn A. APPLICATION TYPE (each application type includes a $5 technology enhancement fee) FIRE SPRINKLER SYSTEM STORAGE TANKS ❑ COMMERCIAL TI - 1-9 HEADS NO FEE ❑ DISPENSERS ONLY $217 ❑ COMMERCIAL TI -10 + HEADS $619 ❑ ABOVE GROUND - I TANK $217 ❑✓ RESIDENTIAL - TRACT HOME - MODELS $619 ❑ ABOVE GROUND - EACH ADDITIONAL $32 ❑ RESIDENTIAL - EACH ADDITIONAL UNIT t $126 EA ❑ UNDER GROUND — $217- RESIDENTIAL - CUSTOM HOME $619 MISC FIRE ALARM SYSTEM ❑ HAZMAT $589 ❑ COMMERCIAL -SPRINKLER MONITORING $192 ❑ HIGH PILE RACK STORAGE $353 ❑ COMMERCIAL - FIRE ALARM SYSTEM $632 ❑ NEW COMMERCIAL - UNDERGROUND WATER $701 SUPRESSION SYSTEM ❑ FIRE FLOW REPORT $178 ❑ HOOD & DUCT $215 ❑ TECHNICAL REPORT RESEARCH $589 ❑ SPRAY BOOTH $215 ❑ SPECIAL INSPECTION $126 Cl CELL SITE $215 ❑ ITEMS NOT LISTED ARE ON A SLIDING SCALE STARTING AT -------------------------- $197 ❑ OTHER SUPRESSION SYSTEM $215 These are Deposit Based Fees. There maybe additional money due prior ;o or otter project final.