Loading...
FCMP2020-0001 Griffin Ranch Plan 5a u�tt Project Details PROJECT NUMBER ` =�w City of La Qu i nta FCM P2020-0001 MoFT�• . Description: GRIFFIN RANCH / MASTER FIRE SPRINKLER PLAN 5 (4154) Status: APPROVED Type: FIRE CONSTRUCTION MASTER PLAN Status Date: 1/28/2020 Subtype: FIRE SPRINKLER MASTER PLAN Applied: 1/28/2020 Address: 81181 MERV GRIFFIN WY Approved: 2/18/2020 City, State, Zip: LA QUINTA,CA92253 Closed: Project Manager: Expired: Details: Pr DAYS REVIEWS III ACTIONS INSPECTIONS CONDITIONS 0 0 • CHRONOLOGYTYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE KOHL HETRICK 2/18/2020 2/18/2020 FIRE REVIEW ASSISTED BY AFM CHRIS COX NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST STE 200 CORONA CA 92879 jamieb@fireinc.net CONTRACTOR FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST STE 200 CORONA CA 92879 jamieb@fireinc.net OWNER IOTA GRIFFIN 4675 MACARTHUR CT NO 1550 NEWPORT BEACH CA 0 Printed: Wednesday, February 15, 2023 2:56:55 PM 1 of 3 CENTRALSOLIARE a u�tt Project Details PROJECT NUMBER ` =�w City of La Qu i nta FCM P2020-0001 MoFT�• CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY FIRE STAFF - PER HOUR 101-0000-42420 1.5 $241.50 $241.50 2/19/20 R59762 236666 CHECK FIRE SPRINKLER AHI SYSTEMS INC Total Paid for FIRE FEES: $241.50 $241.50 RECORDS MANAGEMENT FEE - 101-0000-42416 0 $21.00 $21.00 2/19/20 R59762 236666 CHECK FIRE SPRINKLER AHI SYSTEMS INC MAJOR Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00 TECHNOLOGY 502-0000-43611 0 $5.00 $5.00 2/19/20 R59762 236666 CHECK FIRE SPRINKLER AHI ENHANCEMENT FEE SYSTEMS INC Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES DATE DATE RETURNED REVIEW TYPE REVIEWER SENT DATE DUE DATE STATUS REMARKS NOTES DATE 1ST FIRE (2WK) KOHL 1/28/2020 2/11/2020 2/18/2020 APPROVED REVISED MASTER TRACT PLAN. APPLICANT HETRICK REFERENCED FSS2017-0037 - PLAN 5(4154). 1ST PERMIT JACK LIMA 1/29/2020 1/30/2020 1/30/2020 COMPLETE TECHNICIAN (1DAY) :•RR •• • IMF Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/18/2021 JOSE DELGADO Fire Review Application.pdf Fire Review Application.pdf 0 Printed: Wednesday, February 15, 2023 2:56:55 PM 2 of 3 CENTRALSOLIARE ° Project Details PROJECT NUMBER yow City of La Qu i nta FCM P2020-0001 OFTt ILOM Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/18/2021 JOSE DELGADO Hydraulics Calculation Hydraulics Calculation 0 Report.pdf Report.pdf DOC 4/28/2020 KAYLI ALFORD 31630-DE Master Plan 31630-DE Master Plan 0 41S4 (AsBuilt3).pdf 41S4 (AsBuilt3).pdf Printed: Wednesday, February 15, 2023 2:56:55 PM 3 of 3 CENTRALSQUARE a Bulletin 006 Rev, I W Model RFC30 (SIN RA061 1) I C Model RFC43 (SIN RA0612) CD H 11abld Model RFC49 (SIN RA0616) Residential Flat Concealed I Sprinklers A Residential Fiat Concealed Sprinkler englnewedfor a minimum design density of 0.05 gpmV with low GPM requimmerft Features Y. 1. Very low water flow requirements. 2. Cover plate attachment (Plain or Perforated) witli 'ho (13mm) Total adjustment. 3. Thread-On[Thread-Off or Push-On/Thread Off cover attachment option. 4. Smooth aesthetic ceiling profile. 5. Available in brass, chrome and black plated or painted finishes. Plain Cover Rate Listings & Approval 1. Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) UL Listing Categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...... .......... ... ................ Residential Automatic Sprinklers UL Guide Number VKKW Product Description Model RFC30, RFC43 and RFC49 Concealed Residen- iial Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Perforated Cover Plate Model RFC30, RFC43 and RFC49 sprinklers discharge water in a hemispherical pattern below the sprinkler de- and positively attached and blends into the ceiling, con- fiector, Residential distribution patterns are higher and cealing the most dependable fire protection available, an generally contain a finer droplet size than standard sprin- automatic sprinkler system, kler patterns. The RFC30, RFC43 and RFC49 are UL Listed Residen- The combination of speed of operation and high dis- tial Sprinklers to be installed in the residential portions charge pattern required for residential sprinklers has of any occupancy in accordance with NFPA 13, 13R, & demonstrated, in fire testing, an ability for controlling 13D, residential fires, and thereby providing significant evacu- The RFC30, RFC43 and RFC49 can reduce the need ation time for occupants, for precise cutting of drop nipples, The threaded cover The RFC30, RFC43 and RFC49 Sprinklers provide the plate assembly can be adjusted without tools to fit ac- besttorm of fire protection by combining an attractive ap- curately against the ceiling. The fire protection system pearance and 'A" (13mm) of cover adjustment for ease need not be shut down to adjust or remove the cover of installation. The small diameter cover plate is easily plate assembly. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Thread Nominal Sprinkler CCP Assembly Max. Ambient K Max. Model Size Orifice Temp Rating Temp, Rating Temp. Factor Pressure K (SIN) Inch (mm) Inch (mm) psi (bar) OF Oc OF OC OF OC RFC 30 2 2 86 74 1 345 57 0 3,(43.2'1 A 175 021 (RA0611) RFC 43 74 57 100 3, B 4.3 ;52� 17C, (119' (RA0612) RFC 49 "A '65 `4 '36 100 38 4.9 /0. 6) W5 (RA0616) J Note 11 bar 100 Kpa RFC 30 ordinary Temp. Rating Top of Deflector Minimum I Max. Coverage Max. Spacing (1 65-F/74-C) to Ceiling Installation spacing I Flow Pressure area Ft (m) Ft x Ft (m x m) Inch (mm) Type Ft (m) --- ---------- ­_­ -------------- ---------- ----------- --------------- - GPM (L/min) ---------- ­­ -­------------­------- PSI (bar) ----_---------------­ --------- ----------------- --------------------- ------------- ­---------------­- ------------- ------------- ---------------- ----------- ---------------- -:1 x '9 (3,6 x 3,6) 12 135) 9 (34, 1) 9.0 `0,62' St uot". Ce-Nngs '/2 to 1 (13 o 25.4 T'. edCpik' gq. per :NFPA 13 D, 13R -onc, Pa'e d 8 2,4) '4 x .4 (4, x 4,3' 14 (4,3' C,333 77�Vj 1 0, 7 e, 113 tc 1�1 insMdked n! be_-,a-'1S V2 to Q i For Ceili;;g types refer to NFPA 13, 13R or 13D RFC 43 ordinary Temp. Rating Top of Deflector Minimum Max, Coverage Max. Spacing (1 ®F/74°C to Ceiling Installation i Spacing Flow Pressure area Ft x Ft (m x m) Ft (m) Inch (mm) Type Ft (m) GPM (Umin) PSI (bar) 1Dx1Z (3,6 x 3 6, 12 (73,6) 12 (4, 5) 7, 8 0,5 4 Sir"lloot 1 Ced..ngs ';V,. to 1 (13 "o 5.4' 14 X 14 M3 x 4.: 1 A 4, 3) 13 (49) 91 16 x 16 4,z-) x 4,9) 13 '449', 1-4.1 '0)63" Bparned CFiI r aer NFRA 13-', 13R or 13 -stai:ed in bo�arns- '/zto 1 (13 to 2_E"A) Cori cen, �P(J 8 !2,41 18 X 18 15,5 X 5,5' t-\ 18 (,") 18 (68) 17 5 1,21% 20 x 20`6.1 x S. 1' 90`6,1) 21 (7 g iyp s refs3r t,- N' FPA 13, 13K 01' 1J1 E:f% AM Ordinary Temp. Rating Top of Deflector Minimum. Max, Coverage Max. Spacing (165' 4-C) ................... to Ceiling Installation Spacing area Ft (m) Flow Pressure Inch (mm) Type Ft (m) Ft x Ft (M x m) GPM (Umin) PSI bar 12 x 12,"3,6 x 3,6;' 2 (3,6) 13 (49) 0 (0,481 Sn,Cotn Codw,06, -V'2 to 1 '13 tv 25.4',* 14 x 1411,14,3 x 4,3) 14 (4,34) 13 49) 16 x 16 ( 4,9 x 4, c_�,) 6 (4,91 13',49) �0,48'pmed 7�0 ;' Be C04 � s net NFPA 131.�D, 13R or I S t 13 in boarr s1A,,o 1(1- o 25.4' ConceMed 8 "2,4) 18 X 1815,5 X '55) 8 .17 (64,31 0,831 12. 0 ( I r2 J X 21) ,6X 611, 20(6,1) 20(75, 13) 163. 11 11; 14) -or Cedn`ig tybcjs refs: to NFPA 13, 13R or 1311J Billetin 135:3ev. L Ir MoM F1 rt Resi&nU Sim inklm for R11�111abld Design Density of .05 9PW Model F1 Res SpirkWeirs e4imered for the bwast fbWe lo most the minknum design derisilly of Z gpmW Types: F1 RM 30 Pe-1030t 2. F1 Pee 30 Reoessed Percent 3. F1 Res 80 Raciessed PencerTr-P 4. F1 Fes 49 Pendent 5. F1 Res 49 Rpoessed PencerrF-1 6. F1 Pa 49 Roomed Pencemr-P 7. F1 Res 58'Pe-dent F I Pas 30, 49,59 3 76 F1 Fies 30, 419, 58 & TS 8. F1 Pes 58 1 Re-v4sed PencerrF1 Recessed Penderr/H Remssec. DendentF::P Res 5E HSVJX 9. F1 Rgs 58 Reused PencerrFP -0. F1 Fps 76 Pe -dent te� - 1. F1 %s 76 Recessed PencerrF1 iL, ift -2. F1 Pes 76 Re--med PencerrFP I,?. ME -3. F1 Pes 30 CCP Pendent -4. F1 Res 49 (X,P Pandert -5, F1 Res 58 COP Pendent '6, F1 Fin 76 (—,P Pendert 7. F1 Res 44 FEW F- Res K, 49,58 & 76 F' Res 44 & 58 F1 Res 44 SWC -8. F1 Res44- Roomed HSW)F2 C3P Pendent Recessed HSWf 2 9. F1 Fles 58 FEW Horizonte] SidwA, sprinklers (Figs. 5,6 & 7) are aquall� Vac- 21 F1 Res 58 HISWX ive Wwi above celling piping carrot be used 21, KRes58 HSWX The 3mm gLc�lb penderl sprinker- pernit the elfident Lse 22. F1 Res 58 F&V Reomed HSWF2 23. F1 Fes 44 SWC of residentiamer supplies fa sprite --overage ir -esidentid Ustings & Approvals f re P'orectlol design, Thelowflaw:1 Reseprinklieve are aWialy engireered fo, fast Ls'led by Urderwitera Laboramriss na and twmcl rasponm to meal the ssrisIT/9 'to protection applica- UL Carto ea jor Canaca ','cULLs; ton reads of :M uteol: md dart at marks standards (UL 1,:E6 Standard). Upon tre conditims, rising heat camsaspnnK ert Sprinklers fcw.10 Done* Refer to Bulletin 176 r%E-QonsawdemeM,ga3sbulborhnK$)ac�uM[01&zwingte UL Usting Catlegory waWvuW-brmiTfbwcriothecdector,--venydsrrjuDngte R—mizentiEl Autorna-i_- Sprinkler Technical waler t =nt-ol afire. Technical Data: UL Guide Number * Tretinal Sio-w- Solcered Elarnien: (Unk) cr Nom nal VW4V 3111n gla88H-,UIb Patents a Sprinkler Frame. BrassiCastirg US Patent No. E,51 6,893 applies to the Model F1 Res 49 * Sprirklers'P,essure Rai ng: 175 psi & 53 :;encent Sprinklers Facto,y 1-ydroglat tally Tested to 500 psi US Patent Nc. 7.353,682 app iss to Model F1 Res 44 & 58 - RreadSize. W'1417171,1`11%) HSW Spir ink ers 9 K-Facto` C.0(43Z(Acma)-FlF3a-.3DPwdeT.Sprh4er USPaten No. 7.784,555 applies to Model F I Res44SWG- 4,9(?W AchA - F1 Res Q PendartSprnWer Sprinklers 53 (63.5) �ck•al! .-F 1 Res.5B Pendsn-& HWI Spinider Product Description 7.8(13P~ - Ft Res 76 Poickd8prinliler Model F1 Res PerderT spirinkers T,-i_m 1, 2, 3, & 4) are NT. 4.4(33)(Actual) - F1 RasL4 -ISW Sori*er rsqxrse sprinklErs combni-g ewalero dLrabi ify, NO- awsitiv- * Densiiy- minimim a 05 gpmff? 4yglasL---uloand lcwpr(AlacecoraM doeig-t The F1 Res The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Technical Data: F1 Res 30 Pendent and Recessed Pendent (SIN-R-35-1-1) - ---- ---- -- ------------------------------------------ - ------------------------------------------ Inol Oiifica i Kmc Pr arc 22 Sprinkler Temp. Rating Max Ambient Tsars 1 Actual K I Sprinkler Length QC I oc sizo Inch (mrri) 1 psi (bar) ()F I ------ -----asts�r inch (mint} ------- -------------------------------------------- ----------------------------- -- ---------------- --------------------------------------- 1 Cr,) 3a 30(43.2j 1-26(67) �8. 2) i76 (12) 1 175 70 GrdinaryTmp. Rifing 1! Intormodiato Tomp. Rating; i Minimum Moc. Coverago area M= Spacin (165MBS'O (176OFr19-0 Top of Ddimtor to C611rig i ............................. I. ........ ...... . i Spacing Ft x Ft (m X M) 9 ow Fmasure 1 Flow inch (mirri) Ft (m) Ft (MI P Si (bar) 11 GPINYI (LImin) PSI (baO ------ ------------------ --------------------------------------------------- ----------------------------- ----------------- -------------- ------------------------ ----------------------- C2, 1 7 tn 10 12 x 12 (3,13x 3.6' 1? 113.6) a(30"1 O '0.48) U." 81ijgirig F2eS-.*.L,tc:haor,. ........... ................................................. ........... ................. ............ ..................... BEamed W'irg�p P­'p- 13D_ 13173 E!, '2;4 or 13 irista'1bdir!b&',1-T,9 I'A to is A x 14 (4,3 x 8) 11 (0, IC 71 -i 44 C; 772 t— jj�LM I -or Ceiling t7lxs refer to NFPA 13, 139 or 1 �D Technical Data: F1 Res 49 Pendent and Recessed Pendent (SIN R3516) Max. Sprinkler Max. AzctLiwil Sprinkler Thread Nominal Orifice Pressure Tern Ming Ambi K Length Size .................. __ --- Inch (mm) ------ - -------- - -------- .......... ....... _p ------ ---------- --------- OF -[ * ... -Tem 01� C - - -------- ----- - - ------------------ ­jj Fac -------- ----- ------------------ ------- (I J) 1 7_5 112) 68 1100 38 4 0 Ye) C; 2.2E,'57 17,5 79 1,90 66.. Ordinary Temp. Reding Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (1 W' Q 175W9'C) to Ceiling Spading Flow Pressure Flow Pressure FtxFt(mxm) Ft (m) Inch (mm) Ft (m) --- - ---- M - I ------- MR ------- ----- ------ - -------- - ------------------ - -------_------------ '2 x 12(3,6 x 3,6) --------------...--------------....-GPM- 3 (49) 7.0 (-OA8) �ftft 1'� "19) 7, C' ', 0, 4 8) Smooth Ceilings !Y4to 4 (31,7 to 102) UShg F-2 escutchaoin. 1 to 4 (25.4 to 1 CZ,1 ushz- - l- peNFPA. 8 (2,4j 1 46 x 14 (4,3 ) x 4.3) 14 (4, 3) 3 (49,t 7.0 (0,48! 13 70 (0,48) 6 x 16 (4,9 x 4,9) (4,P) -13 (49) 7.0 (0,48) 135 7 0 '''('4, 8) ----- ---- --... ---- - ---- ----- ----- - -- - ---- ------------------ ---------- I aD, 13R or 131 instalC 1. 8 X 18 (S. X 8 1 7 (C 12 (0 -,83) 7 84,3" 2 1-0:8 3) uearn�� 11/4' (31.7'_j �5 114 4) urz;ng 2 e-'J.-W—hoon, 1 to 1:K ('25A to 44.4�i using F1 �10 x 20 f 6,1 x 6, 1) 20(65,1) 2 G ( /6; 1') 16.1 OJ-1 20f 75, 1 , 4) I ---------- -------------- --- ---- ---- ---------------------------- --- ---- -- - -------- ------ ------- - -------- ------ -- - -------- ------------------­ ­­ - ----------------- Fra. Cei.m.gtypes refer to NFPA, 1:, 1"3Ror 13D HYDRAULIC SYSTEM This Building is Protected by a Hydraulically Designed Automatic Sprinkler System. Date Installed 8/15117 Location CALC AREA 2 Number of Sprinklers 2 Basis of Design 1. DENSITY - .05 gpm/sq.ft. 2. DESIGNED AREA OF DISCHARGE 512 sq.ft. System Demand 1. WATER FLOW RATE 31.0 gpm 2. RESIDUAL PRESSURE AT THE BASE OF THE RISER 49.2 psi Installed By Fire Sprinkler Systems, Inc. HYDRAULIC NAMEPLATE N.T.S. PRESSURE REGULATOR TO BE SET AT 60 PSI S1 TO DOMESTIC WATER CONTROL VALVE FOR DOMESTIC \5 GPM ALLOWANCE 104 2' ELEV. CONTROL BALL VALVE FINISH GRADE O'ELEV. 1 W COPPER L 3/4" MASTER METER BLMJ 9.5 PSI LOSS 4- 1%" PVC 1' COPPER K METER MAIN TY ==Z< cl !! 103 70'MAX �� 30' MAX. -2' ELEV. 100 -2 ELEV. -2 ELEV. ALT UNDERGROUND DETAIL N.T.S. (FOR REFERENCE ONLY) 13D/CRC 313.3 GENERAL NOTES 1. AUTOMATIC FIRE SPRINKLER SYSTEM HAS BEEN DESIGNED TO BE REQUIREMENTS NSTALLED IN ACCORDANCE WITH NFPA 13D 2016 EDITION AND THE REQUIREMENTS OF THE CITY OF LA QUINTA HIRE DEPARTMENT. 2. THIS SPRINKLER SYSTEM SHALL BE TESTED AND INSPECTED BOTH THE ROUGH AND FINAL INSPECTION PRIOR TO OCCUPANCY BEING GRANTED. THE JURISDICTIONAL FIRE PREVENTION OFFICE WILL BE NOTIFIED A MINIMUM OF TWO WORKING DAYS IN ADVANCE OF THE REQUESTED INSPECTION. 3. THE INSTALLER SHALL PERFORM ALL REQUIRED ACCEPTANCE TESTS. 4. NOTCHING, DRILLING, OR OTHERWISE PENETRATING STRUCTURAL MEMBERS SHALL BE IN ACCORDANCE WITH CALIFORNIA BUILDING CODE. 5. TYPE OF PLASTIC PIPE TO BE CPVC MANUFACTURED BY BLAZEMASTER U.L. LISTED. 6. ALL VALVES SHALL HAVE A PERMANENTLY AFFIXED SIGN INDICATING IT'S FUNCTION F 1 AVENUE AVENUE 51 W 5_' 0 PW i_ of AVENUE 52 Z 0 no AVENUE 53 U_ W t_U W Ix AVENUE 54 w H SITE 0 W 1-u Ln w W QO W 'M a& tin Z Z 0 Z 0 AVENUE 11CINITY MAP 0 Lon AIRPORT R na NTS 0 LU Of 2; LU ca LU LU LU W 5; U.J C/) zz I— LU LU I— LU zt 0 F_ CL 0 C.9 CD in M t:-: M UJ M CM < 55 1 1 1 1 C' U') V C=' VICINITY MAP 7. PIPE SHALL BE HUNG FROM STRUCTURAL MEMBER PER THE UNIFORM PLUMBING CODE. PIPE CLAMPS AND SCREWS ARE MANUFACTURED BY N.T.S. AFCON MFG. ARE U.L. LISTED AND ARE INSTALLED ACCORDING TO THE HANGING REQUIREMENTS IN THEIR TECHNICAL DATA (SEE DETAIL). GRIFFIN RANCH 8. THE SPACING AND LOCATION OF SPRINKLERS SHALL CONFORM WITH MASTER PLANS THE MANUFACTURES REQUIREMENTS AND THOSE CONTAINED IN TRACT 32879 * PLAN 4154 NFPA 13D, 2016 EDITION. 9. IF REQUIRED BY A.H.J. THE ALARM INDICATING DEVICE SHALL BE LISTED FIN. SPRINKLER SYNEM INC. FOR OUTSIDE SERVICE AND AUDIBLE FROM THE STREET THAT THE 0 HOUSE IS ADDRESSED ON. LICENSE NO. 684600 10. SMOKE DETECTORS TO BE INSTALLED BY OTHERS. 0 11. RESIDENTIAL CONCEALED PENDENT SPRINKLERS ARE U.L. LISTED AND LA QUINTA, CA. CUSTOM, TRACT, MULTI -FAMILY AND COMMERCIAL MANUFACTURED BY RELIABLE INSTALLED AT 16 FT. MAXIMUM SPACING AHJ: CITY OF LA QUINTA (SEE TECH. DATA). DESIGN, ENGINEERING AND LEGAL DESCRIPTION INSTALLATION 12, PENDENT INTERMEDIATE TEMP. QUICK RESPONSE SPRINKLERS ARE U.L. 0 LISTED AND MANUFACTURED BY RELIABLE INSTALLED AT 16 FT. MAX. SPACING 705 E. HARRISON ST., SUITE 200 (SEE TECH. DATA). OCCUPANCY: R3/U CORONA, CA 92879 13. PENDENT SPRINKLERS ARE AT LEAST 3 ft. FROM OBSTRUCTIONS E.G. LIGHT CONSTRUCTION: V-B PH - 800-915-3473 FAX - 951-272-2535 FIXTURES CEILING FANS, ETC. OR IN ACCORDANCE WITH TABLE 8.2.5.3.2 AND SECTION $25.1. SPRINKLER LOCATIONS FOR CONTINUOUS OBSTRUCTIONS STORIES: 1 0 ARE IN COMPLIANCE WITH 8.2.5.3. BUILDING AREA: 4,832 SQFT. The recipient of these plans here acknowledges that all hereby 14. SOFFITS AND CABINETS TO BE PROVIDED WITH SPRINKLER COVERAGE IN FIRE SPRINKLER SYSTEM: Is, specifications or methods of installation ACCORDANCE WITH 8.2.5.5. DESIGNED AND INSTALLED PER 2016 NFPA 13D ALL contained in this set of plans is 15. SPARE SPRINKLERS SHALL NOT BE REQUIRED TO BE PROVIDED IN RESIDENTIAL WITH A.05 DENSITY WITHIN AREAS. the sole property of Fire S nkler Systems, Inc. and ACCORDANCE WITH 5.1.1.2. SCOPE OF WORK: that an use of this set of plans is prohibited and is a violation FIRE SPRINKLER DESIGNED AND INSTALLED PER 2016 of copyright lawswithout first 16. NFPA13D 8.3.5.1.1 WHERE THE FUEL -FIRED EQUIPMENT IS ABOVE ALL OF THE NFPA 13D ALL RESIDENTIAL WITH A.05 DENSITY WITHIN Mi receiving permission from Fire OCCUPIED AREAS OF THE DWELLING UNIT, NO SPRINKLER PROTECTION SHALL AREAS RESIDENTIAL WITH A.05 DENSITY WITHIN AREAS. S rinkegr stems. BE REQUIRED IN THE CONCEALED SPACE. SCOPE OF WORK TO START AT BASE OF RISER (NODE 104). BUILDING SUMMARY Z UJ CONCEALED RES. PENDENT SPRINKLER (D CONCEALED RES. PENDENT SPRINKLER O RESIDENTIAL PENDENT SPRINKLER CHANGE IN ELEVATION M RISER LOCATION (PER DETAIL) Z ONODE POINT FOR CALCULATION < HANGER TIC DETAIL U) SYMBOL LEGEND O APPROVAL UJ Depart,, i nt Riverside CoMtl/ Fire nee 2— IV �/ao LU C= Z Ely:® �pl;ans UJ `a)e appnw�aljof and speci caoc-, 0 ces the violation, deietion, otriissi0i' O� faulty !E 1111110 117% permit installation Of any requirements of Title 24 or any i-ocal Ordinances. Construct -ton shall remain for inspection purposes until SV accessible* and exposed approved by the Fire Department. LU PRESSURE REGULATOR TO BE SET AT 60 PSI TO DOMESTIC WATER CONTROL VALVE FOR DOMESTIC \5 GPM ALLOWANCE O104—2'ELEV. CONTROL BALL VALVE FINISH GRADE O'ELEV. 11/4" COPPER L � 103 1 -2' ELEV. 11YA" PVC TOR REFERENCE ONLY I 1" METER 4 PSI LOSS N.T.S. (FOR REFERENCE ONLY) CM!%�N -2 ELEV. CPVC TO SYSTEM SPARE SPRINKLERS SHALL NOT BE REQUIRED TO BE PROVIDED PER 5.1.1.2 'IT LO er :I— U)Z <C CS Z a- > Z: LU CC,04 CY Cn APPROVAL STAMP <M < CID �_I­— J GAUGE Y2"MAIN DRAIN VALVE DRAI TO EXTERIOR RUBKR FACED CHECK VALVE 3 PSI 17 KtNUUAL N.0 - I U'/o = bt.34 105 4' ELEV. FLOW 2,300 GPM IWATER FLOW INFORMA MAI 104 Li 2' ELEV. SHEET ID RISER DETAIL GENERAL NOTES N.T.S. I \ SHEET FP1 OF FP4 HYDRAULIC SYSTEM This Building is Protected by a Hydraulically Designed Automatic Sprinkler System. Date Installed 8/15/17 Location CALC AREA 2 Number of Sprinklers 2 Basis of Design 1. DENSITY .05 gpm/sq.ft. 2. DESIGNED AREA OF DISCHARGE 512 sq.ft. System Demand 1. WATER FLOW RATE 31.2 gpm 2. RESIDUAL PRESSURE AT THE BASE OF THE RISER 51.1 psi Installed By Fire Sprinkler Systems, Inc. 1-HR, AND 2-HR. GYPSUM WALL ASSEMBLY PLASTIC PIPE THROUGH GYPSUM WALLS USING BLAZEMASTER CAULK & WALK F RATING =1-HR. AND 2-HR. T RATING =1-HR. AND 2-HR. DRAWING NOT TO SCALE 1. PRE -RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY A) THE F RATING =1 HOUR IF THERE IS ONE LAYER OF GYPSUM WALLBOARD. B THE F RATING = 2 HOUR IF THERE ARE TWO LAYERS OF GYPSUM WALLBOARD. 2. PLASTIC PIPE - A) NOM. 2" DIAM. (OR SMALLER) SCH. 40 PVC PIPE B) NOM. 2" DIAM. (OR SMALLER) CPVC PIPE. THE ANNULAR SPACE RANGE SHALL BE ,MIN.1/4" TO MAX 1-3/8'. NOTE: FOR USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. 3. BLAZEMASTER CAULK & WALK - MIN. 1/2" THICKNESS OF SEALANT APPLIED WITHIN OPENING. ADDITIONAL SEALANT TO BE INSTALLED SUCH THAT A MIN. 1/4" CROWN IS FORMED AROUND THE PENETRATING ITEM. NOTE: THE F & T RATINGS OF THE SYSTEM IS EQUAL TO THE FIRE RATING OF THE WALL ASSEMBLY. UUcUL SYSTEM NO. WL2151 PLAN 4154 FIRE SPRINKLER PLAN SCALE: 1/4" =1'-0" SIZE - SYSTEM PIPE: 3/4" thru 3" MATERIAL - CARBON STEEL. FINISH - Mil. Galvanized. LISTING/APPRO/�V�LA„,L - "Ym 203-EX 4231, EX 2551 FUNCTION - Support horizontal piping: CPVC, Copper or Steel. Size 3/4" - 2" Prevents upward movement of pipe from pendent sprinkler discharge. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. install on horizontal or vertical mounting surface. FASTENERS - UL Listed per NFPA 13 in WOOD: 3/4" - 3" CPVC PIPE - #905 screw - no pre -drill. 3/4" - 3" Steel and Copper pipe - #14 x 1 1/2" SMS or 1/4"xl 1/2" lag bolt - no pre -drill. in STEEL: min. 18 GA. 3/4" - 3" CPVC, Copper and Steel pipe - 1/4" or #14 Tek Screw. FEATURES ' Offset edge eliminates abrasion. Retainer dimples secure hanger to pipe during installation. * Required AFCON #905 screw included - 5/16" hex head. ORDERING - Part # and pipe size. CAN ALSO BE USED TO REPLACE - #500 Pipe Strap #520 Tin Strap Hang 510 DI FAST. SIZE M. 3/4 12.1261 g2.312 3.170 3.400 4.320 3 5.320 Nominal Pipe Size (in.) 3/4" 1" 1'/4" 1'/" 2" 2'/z" 3" 3W 4" 5" 6" 8" Steel pipe except threaded N/A 12'-0" 12'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" lightwall Threaded lightwall steel N/A 12'-0" 12'-0" 12'-0" 12'-0" 12'-0" 12'-0" N/A N/A N/A N/A N/A pipe Coppertube 8'-0" 8'-0" 10'-0" 10'-0" 12'-0" 12'-0" 12'-0" 15'-0" 15'-0" 15-0" 19-0" 15'-0" CPVC 5'-6" 6'-0" 6'-6" T-0" 8'-0" 9'-0" 10'-0" N/A N/A N/A N/A N/A Polybutylene (IPS) N/A T-9" 4'-7" 5'-0" 5'-11" N/A NIA N/A N/A N/A N/A N/A Polybutylene (CTS) 2'-11" 3'-4" T-11" 4'-5" 5'-5" N/A N/A N/A N/A N/A N/A N/A Ductile iron pipe NIA N/A N/A NIA N/A 15'-0' NIA N/A 15'-0" N/A 15'-0" 15'-0" AFCON 510 HANGER (STEEL - COPPER - C. P. V. Q NOT TO SCALE �t 1� SIZE - SYSTEM PIPE: 3/4" thru 2" MATERIAL - Carbon Steel. ` FINISH - Mil. Glavanized. LISTING/APPROVAL - `- 203-EX 4231, EX 2551 PATENT - No. 6,648,278. FUNCTION - Support horizontal piping: CPVC, Copper or Steel. Provides listed vertical/horizontal restraint and prevents upward movement of pipe from pendent sprinkler discharge. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. Snap over pipe then squeeze strap back allowing pipe to slide freely. When #905 threads are exposed in wood, install #906 backing nut. FASTENERS - UL Listed per NFPA 13 WOOD - CPVC pipe #905 screw- no pre -drill. Copper and Steel pipe - #14 SMS or 1/4 "xl 1/2" lag screw - no pre -drill. Thru 5/8" gypsum board - 1/4"x 2" lag screw. STEEL - min. 18 GA. - CPVC, Copper and Steil pipe - 1/4" or #14 Tek Screw. CONCRETE: Required minimum load each Easterner = 5(wt)+250lbs. 2 FEATURES * 1 1/2" Offset - loose fit allows pipe to slide. Common center -line for 3/4" and 1". * Offset edge eliminates abrasion. AFCON #905 screw included - 5/16" hex head. ORDERING - Part # and pipe size. AFCON #906 backing nut sold serparately. N905 #gpfi 7.50 3.00 Hanger/Restrainer Z Z N LULU Z U ¢ ^ a V O Z O = a 0 Q o 13- O W U � = -cc J Lu w LUO LU m Q Lu in W or ceD Q Q J Z - J m LU LU o Q co Q Q w Q ti � o fM rn 00 M o N N - ibilize Z < \i \I I I! Restraint I Stabilize (\ Nominal Pipe Size (in.) '/4" 1" 1%4" 1'/" 2" 2'/" 3" 3%" 4" 5" 6" 8" Steel pipe except threaded N/A 12'-0" 12'-0" 15'-0" 16-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" lightwall Threaded lightwall steel N/A 12'-0' 12'-0" 12'-0" 12'-0" 12'-0" 12'-0" N/A N/A N/A N/A N/A pipe Copper tube 8'-0" 8'-0" 10'-0" 10'-0" 12'-0" 12'-0" 12'-0" 16-0" 15'-0" 15'-0" 15'-0" 15'-0" CPVC 5'-6" 6-0" 6'-6" T-0" 8'-0" 9'-0" 10'-0" N/A N/A N/A N/A N/A Polybutylene (I PS) N/A T-9" 4'-7" 5'-0" 5'-11" N/A NIA N/A N/A N/A N/A N/A Polybutylene (CTS) 2'-11" 3'4" T-11" 4'-5" 5'-5" NIA NIA N/A N/A N/A NIA N/A Ductile iron pipe N/A N/A NIA N/A N/A 15-0" NIA N/A 15'-0" N/A 15'-0" 15'-0" AFCON 514 HANGER (STEEL - COPPER - C.P. V. C. ) NOT TO SCALE APPR.OVAL Riverside County Fire Department Office oT ` e e ilorshal By: The approval of plans and specifications does not permit: the violation, deletion, omission or faulty installation of any requirements of Title 24 or any L Ccal Ordinances. Construction shall remain ac,;:essit�k: and exposed for inspection purposes uC' , O.uu by ",is Fire Department. FLOOR AREA - 4,154 SQFT. TOTAL LIVING AREA - 4,154 SQFT. GARAGE AREA- 678 SQFT. DESIGN AND INSTALLATION SHALL CONFORM TO NFPA 13D, 2016 ED. NOTES: 1. ALL HEAD SPACING TO BE 16'x16', UNLESS OTHERWISE NOTED. 2. ALL PIPES TO BE %" CPVC, UNLESS OTHERWISE NOTED. 3. PIPE CLEARANCES MUST BE IN ACCORDANCE WITH NFPA 13-9.3.4. 4. HANGERS SHOWN FOR REFERENCE PURPOSES ONLY. HANGER SPACING TO BE PER TABLES ON THIS SHEET. 5. SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55sgft. AND LESS. (SECTION 8.6.2.) 6. SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THAT MEET ALL OF THE FOLLOWING REQUIREMENTS: (1) THE AREA OF THE SPACE DOES NOT EXCEED 24sgft. (2) THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED -COMBUSTIBLE MATERIALS AS DEFINED IN NFPA 220. 9. 8.2.5.1.2 THE DISTANCE SHALL BE MEASURED FROM THE CENTER OF THE SPRINKLER TO THE CENTER OF THE OBSTRUCTION. 10. 8.2.5.6 SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS THE CUMULATIVE DRY AREA DO NOT EXCEED 15sgft (1.4 sqm) PER SPRINKLER. FIRE SPMNKLER = Ums INC, 0 LICENSE NO.684600 0 CUSTOM, TRACT, MULTI -FAMILY AND COMMERCIAL 0 DESIGN, ENGINEERING AND INSTALLATION 0 705 E. HARRISON ST., SUITE 200 CORONA, CA 92879 PH - 800-915-3473 FAX - 951-272-2535 0 The recipient of these plans hereby acknowledges that all plans, details, specifications or methods of installation contained in this set of plans is the sole property of Fire Sprinkler Systems, Inc. and that any use of this set of plans is prohibited and is a violation of copyright laws without first receiving permission from Fire Sprinkler Systems. QM co co co co co CO w 2 U' _ Z Fo ZD o a _X _D N Ui w J Y Z W ' � J < O w LL_ _CO Co to O � r- ~ CU < M M M Y d v J Ci Z rnF- 6 Z -J LU O)W �a(nW �tZ �W Va O U LU U O LLU � �Z CCU � O wLLJ a O U U LL LLI _! J J 73 Z m Q m Q m t LO U Z ZZ Q� U q� -t a a,z ?wI-- U)N =m <F- J 9 JOB NO: 31630 DATE: 8115/17 DRAWN BY: M.N. Q�Ql� (Ol ION CD ti C SIF TION 9�a C-16 ;)o * LI 00 ��9TF OF CA0F���\Q SIZE - 24" X 36" SCALE 1/4" =1' IF SHEET IS LESS THAN 24" X 36" IT IS A REDUCED PRINT SCALE REDUCE ACCORDINGLY SHEET ID FIRE SPRINKLER PLAN SHEET FP2 OF FP4 ra M. 0 OPT. FIREPLACE @MASTER BATHROOM SCALE:1/4" = V-0" MANUF. MODEL SYMBOL K-FAC. ORIFICE TEMP. SPACING SIN # QUANTITY RELIABLE RFC49 CONC. PEND. ® 4.9 7116" 1650 16'x16' RA0616 39 RELIABLE F1RES49 PENDENT Q 4.9 7116" 1750 16'xl6' R3516 6 RELIABLE RFC49 CONC. PEND. 4.9 7/16" 1650 20'x20' RA0616 1 TOTAL SPRINKLERS WITH DEN OPTION: 45 6'-6" SCALE:1/4" =1'-0" r GARAGE OPTION SCALE:1/4" =1'-0" APPROVAL Riverside County Fire Department O`l, ce f '' ejEjxe Marshal By: �� X ,e approval or plans and specifications does not permit: the violation, deletion, omission or faulty installation of any requirements of Title 24 or any Local Ordinances. Construction shall remain accessible and exposed for inspection purposes until approved by the Fire Department. :;� z --- Z N U J Z Q O W a F t= Uj O Z Q W O O = N � � w ¢ N w O of of o p _ W v � Ch m Q Q of Q J Z J LPL m m Q U) Q Q W O 0 O M Cl) N ia O Z �W W FIRE SPRONKLER TSINC. LICENSE NO.684600 • CUSTOM, TRACT, MULTI -FAMILY AND COMMERCIAL • DESIGN, ENGINEERING AND INSTALLATION • 705 E. HARRISON ST., SUITE 200 CORONA, CA 92879 PH - 800-915-3473 FAX - 951-272-2535 • The recipient of these plans hereby acknowledges that all plans, details, specifications or methods of installation contained in this set of plans is the sole property of Fire Sprinkler Systems, Inc. and that any use of this set of plans is prohibited and is a violation of copyright laws, without first receiving ppermission from Fire SDrinkler Svstems. • • IT ui r d' U)z Q Z Q� U n- a w I z m �? U) N Gl' Q H JOB NO: 31630 DATE: 8/15/17 DRAWN BY: M.N. Q�O,' �'OT I ON Cp T ti C ATI 9�a C-16 * LIC- __ SIZE - 24" X 36" SCALE 114" =1' IF SHEET IS LESS THAN 24" X 36" IT IS A REDUCED PRINT SCALE REDUCE ACCORDINGLY SHEET ID OPTIONS SHEET FP3 OF FP4 Fig, 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe C& usng Size Range — Available in 3/4" and 1" pipe sizes Material — Pre -Galvanized Steel Function — Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 1 ih" x 1 t/2" from mounting surface. This design will ease installation by eliminating the need for wood block extension and allow retro-fit attachment of hanger to sprinkler pipe. Features --- • Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not required to be bent for listed installation. • Offset edge eliminates abrasion. • Attaches easily to wood structure with two special #10 x 1 hex head self -threading screws furnished with product. • Can be used as a single offset hanger by aligning "dimples" with top of mounting surface and utilizing two fasteners in two of the three holes provided. Approvals — Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish Pre -Galvanized Order By — Figure number and pipe size. PATENT PENDING 0 e soeciai ^ex mad seeif-taupiri Der t-efor _.Lger i;tstallaton, of If mlp.-_r . to ;ha nine h,zf t nr,: Table R • One Point of Restraint MAX. � MAx.I One -Point Vertical \ Restraint RESTRAINT RESTRAINT ONE -POINT ONE -POINT Nominal "ft" ''R" Pipe Size Less than Greater bran ANSI inches ,Ot) psi 100 psi DN (6,9 bar) (6,9 bar) 3f4 0'-9" 0'-6" DN20 (tT,23 m) (0,75 m) DN25 (0,30 m} (0,23 m) DN32 (0,41 m) {0,30 m} DN40 - DN80 (0,61 m) (0,30 m) Janrrary 2005 Garage installation Specifications Garage Installation Specifications shall only apply for the installation of UL Listed BlazeMastere CPVC pipe and fittings in garages requiring sprinkler protection per NFPA 13D and NFPA 13R. These Standards are defined in NFPA codes entitled 'One and Two Family Dwellings and Mobile Homes" and in 'Residential Occupancies up to Four Stories in Refight'. As referenced in NFPA 13D Section 8.6.4,'Sprinktersore not required in garages, open attached porches, carports or similar structures "The installation of TFP BlazeMaster sprinkler pipe and fittings for use in garages requiring sprinkler protection per NFPA 73R is only applicable to the UL listing of this product. Requirements for Pipe, Fittings, Solvent Cement Systems, System Design, Installation, Freeze Protection, and Penetrating Fire Related Waifs and Partitions are covered in this installation and technical handbook. Please read these sections of the manual carefully prior to designing or installing TFP BlazeMaster pipe and fittings for garage installations. The Installation of TFP BlazeMaster pipe and fittings in garages requiring sprinklers Is only UL Listed and is not C•UL Listed. •installation Requirements -Protection: TFP e)azeMaster CPVC pipe and fittings shall be installed concealed behind protection consisting of a minimum of one layer of'!a thick gypsum wallboard or'/z thick plywood. • Sprinkler Requirements: UL Listed, Quick response, standard coverage, pendent or sidewall sprinklers with a 225°F (107°C) maximum temperature rating shall be utilized. All sprinklers shalt be installed per the manufacturer's published installation instructions. -Installation Standard: The Listing for Garage Installations shall pertain to those occupancies defined by NFPA 13R. System Risers In accordance with the UL Listing, TFP BlazeMaster CPVC pipe and fittings may be used as system risers in accordance with NFPA 13.13Dand 73R when subject to the following additional limitations: ,. When installed protected (concealed) in accordance with NFPA 13D and, 3R, the minimum protection shall wnsist of either one layer of 3/s' (g.5 min) thick gypsum wallboard or'/a' (12.7 min) thick plywood. 2. When installed without protection (exposed) in accordance with NFPA 13, 730 and 7311, the following limitations shall apply: - The riser shalt be installed below a smooth, flat, horizontal ceiling construction. A Listed residential pendent sprinkler is to be installed with its deflector at the distance from the ceiling specified in the sprinkler Listing. OR The riser shall be installed below a horizontal unfinished basement ceiling (in accordance with NFPA,30) constructed utilizing nominal 2' x,0' or nominal 2' x 72' exposed solid wood Joists on,6' centers. A Listed residential pendent sprinkler is to be installed with its deflector a maximum of i'(: below the bottom of the solid wood joist in anticipation of future installation of a finished ceiling. When installing TFP 6lazeMaster CPVC pipe and fittings in conjunction with 2' z 12' solid wood foists, the maximum system working pressure under bowing conditions shall not exceed,00 psi and the maximum system working pressure under static (nonflowing) conditions shall not exceed 175 Dsi. •The Listed residential pendent sprinkler is to have,55°F (68°C)maximum temperature rating and is to be installed at a maximum horizontal distance of 72 inches from the center tins of the riser. The system is to be designed based upon the Listed flows for the sprinkler selected except that the flow for a single sprinkler or multiple sprinklers shall not be less than 77 gpm per sprinkler. A 1.500 Single Offset BUIDING SECTIUN LU co f— SCALE: 1/4" = 1'-0" Lco u Janrrary 2005 Garage installation Specifications Garage Installation Specifications shall only apply for the installation of UL Listed BlazeMastere CPVC pipe and fittings in garages requiring sprinkler protection per NFPA 13D and NFPA 13R. These Standards are defined in NFPA codes entitled 'One and Two Family Dwellings and Mobile Homes" and in 'Residential Occupancies up to Four Stories in Refight'. As referenced in NFPA 13D Section 8.6.4,'Sprinktersore not required in garages, open attached porches, carports or similar structures "The installation of TFP BlazeMaster sprinkler pipe and fittings for use in garages requiring sprinkler protection per NFPA 73R is only applicable to the UL listing of this product. Requirements for Pipe, Fittings, Solvent Cement Systems, System Design, Installation, Freeze Protection, and Penetrating Fire Related Waifs and Partitions are covered in this installation and technical handbook. Please read these sections of the manual carefully prior to designing or installing TFP BlazeMaster pipe and fittings for garage installations. The Installation of TFP BlazeMaster pipe and fittings in garages requiring sprinklers Is only UL Listed and is not C•UL Listed. •installation Requirements -Protection: TFP e)azeMaster CPVC pipe and fittings shall be installed concealed behind protection consisting of a minimum of one layer of'!a thick gypsum wallboard or'/z thick plywood. • Sprinkler Requirements: UL Listed, Quick response, standard coverage, pendent or sidewall sprinklers with a 225°F (107°C) maximum temperature rating shall be utilized. All sprinklers shalt be installed per the manufacturer's published installation instructions. -Installation Standard: The Listing for Garage Installations shall pertain to those occupancies defined by NFPA 13R. System Risers In accordance with the UL Listing, TFP BlazeMaster CPVC pipe and fittings may be used as system risers in accordance with NFPA 13.13Dand 73R when subject to the following additional limitations: ,. When installed protected (concealed) in accordance with NFPA 13D and, 3R, the minimum protection shall wnsist of either one layer of 3/s' (g.5 min) thick gypsum wallboard or'/a' (12.7 min) thick plywood. 2. When installed without protection (exposed) in accordance with NFPA 13, 730 and 7311, the following limitations shall apply: - The riser shalt be installed below a smooth, flat, horizontal ceiling construction. A Listed residential pendent sprinkler is to be installed with its deflector at the distance from the ceiling specified in the sprinkler Listing. OR The riser shall be installed below a horizontal unfinished basement ceiling (in accordance with NFPA,30) constructed utilizing nominal 2' x,0' or nominal 2' x 72' exposed solid wood Joists on,6' centers. A Listed residential pendent sprinkler is to be installed with its deflector a maximum of i'(: below the bottom of the solid wood joist in anticipation of future installation of a finished ceiling. When installing TFP 6lazeMaster CPVC pipe and fittings in conjunction with 2' z 12' solid wood foists, the maximum system working pressure under bowing conditions shall not exceed,00 psi and the maximum system working pressure under static (nonflowing) conditions shall not exceed 175 Dsi. •The Listed residential pendent sprinkler is to have,55°F (68°C)maximum temperature rating and is to be installed at a maximum horizontal distance of 72 inches from the center tins of the riser. The system is to be designed based upon the Listed flows for the sprinkler selected except that the flow for a single sprinkler or multiple sprinklers shall not be less than 77 gpm per sprinkler. A 1.500 Single Offset BUIDING SECTIUN LU co f— SCALE: 1/4" = 1'-0" Lco u z � z z � � cn h °- w Q a o � 0 � Z � Q w INC. • LICENSE N0.684600 • CUSTOM, TRACT, MULTI -FAMILY AND COMMERCIAL • DESIGN, ENGINEERING AND INSTALLATION • 705 E. HARRISON ST., SUITE 200 CORONA, CA 92879 PH - 800-915-3473 FAX - 951-272-2535 • The recipient of these plans hereby acknowledges that all plans, details, specifications or methods of installation contained in this set of plans is the sole property of Fire Sprinkler Systems, Inc. and that any use of this set of plans is prohibited and is a violation of copyright laws without first receiving permission from Fire Q Z Q� U W� = m r j c��l C� Q JOB NO: 31630 DATE: 8/15/17 DRAWN BY: M.N. SIZE - 24" X 36" C SCALE Z 1/4" =1' IF SHEET IS LESS THAN 24" X 36" IT IS A REDUCED PRINT SCALE REDUCE ACCORDINGLY SHEET ID SECTIONS FP4 OF FP4 JOB NO: 31630 DATE: 8/15/17 DRAWN BY: M.N. SIZE - 24" X 36" C SCALE Z 1/4" =1' IF SHEET IS LESS THAN 24" X 36" IT IS A REDUCED PRINT SCALE REDUCE ACCORDINGLY SHEET ID SECTIONS FP4 OF FP4 DATE: 11/16/2018 S:\2017\31630\CALCS\4154.rdf Page 1 FIRE SPRINKLER SYSTEMS 705 E. HARRISON, SUITE 200 CORONA,CA 92879 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR GRIFFIN RANCH LA QUINTA, CA PLAN 4154 10°s TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN CALL AREA 1 Date: 11/16/2018 File No: 31630 Data File Name: 4154.rdf SPRINKLER SPACING 400.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 20.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 10.0 ft. SPRINKLER SPECIFICATIONS Mfr: Reliable Descr: RA0616 RFC49 F1 Conc .Pend.(20x2O) K=4.90 Calculated K Factor for Arm-Overs & Drops: 1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee) 0.0 ft. x 0.874 in. Arm -Over: K=4.67 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 74.5 psi Resid: 67.3 psi F1ow:2300.0 gpm Public Main Size: 8 in Domestic Demand: 5.0 gpm at node number 104 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press, Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 20.0 18.0 15 25.0 74.5 51.0 1 20.0 18.0 15 25.0 74.5 51.0 REVIEWING AUTHORITY CITY OF LA QUINTA FIRE DEPT. RECEIVED JAN 2 8 2020 CITY OF LA QUINTA DESIGN AND DEVELOPMENT DEPARTMENT I Sf DATE: 11/16/2018 S:\2017\31630\CALLS\4154.rdf Page 2 RESULTS OF ANALYSIS PIPE & NODE DATA * FLOW ANALYSIS * 1 sprinkler flowing * 1 sprinklers flowing FIXD P # END LEN FIT. LOSS EL SP *DISCH FLOW PF PT *DISCH FLOW PF PT HWC NOD DIA EQV.LN PUMP (FT) (K) *(GPM) FL/FT PE (PSI)*(GPM) FL/FT PE (PSI) 1 100 30.00 BG ---- -2.0 SRCE ---- 25.0 6.05 51.0 ---- 25.0 6.06 51.0 150 101 0.995 6.0 ---- -2.0 ---- ---- 0.17 0.00 44.9 ---- 0.17 0.00 44.9 2 101 1.00 -4.0 -2.0 ---- ---- 25.0 0.17 44.9 ---- 25.0 0.17 44.9 150 102 0.995 0.0 ---- -2.0 ---•- ---- 0.17 0.00 40.8 ---- 0.17 0.00 40.8 3 102 70.00 3L ----. -2.0 ---- ---- 25.0 3.45 40.8 ---- 25.0 3.45 40.8 150 103 1.360 24.0 ---- -2.0 ---- ---- 0.04 0.00 37.3 ---- 0.04 0.00 37.3 4 103 4.00 LG ---- -2.0 ---- ---- 25.0 0.37 37.3 ---- 25.0 0.37 37.3 150 104 1.265 3.0 ---- 2.0 -5 5 0.05 1.73 35.2 5 0.05 1.73 35.2 5 104 2.00 L ---- 2.0 -5 5 20.0 0.17 35.2 5 20.0 0.17 35.2 150 105 1.394 6.0 ---- 4.0 ---- ---- 0.02 0.87 34.2 ---- 0.02 0.87 34.2 6 105 1.00 -3.0 4.0 ---- ---- 20.0 0.02 34.2 ---- 20.0 0.02 34.2 150 106 1.394 0.0 ---- 4.0 ---- ---- 0.02 0.00 31.2 ---- 0.02 0.00 31.2 7 106 7.00 2L ---- 4.0 ---- ---- 20.0 0.41 31.2 ---- 20.0 0.41 31.2 150 10 1-394 12.0 ---- 11.0 ---- ---- 0.02 3.03 27.7 ---- 0.02 3.03 27.7 8 10 35.50 2L5R ---- 11.0 ---- ---- 20.0 3.44 27.7 ---- 20.0 3.44 27.7 150 11 1.101 15.0 ---- 11.0 ---- ---- 0.07 0.00 24.3 ---- 0.07 0.00 24.3 9 11 4.50 R ---- 11.0 --- ---- 15.5 0.72 24.3 ---- 15.6 0.72 24.3 150 12 0.874 1.0 ---- 13.0 --- ---- 0.13 0.87 22.7 ---- 0.13 0.87 22.7 10 12 2.00 L ---- 13.0 ---- ---- 15.5 0.79 22.7 ---- 15.6 0.79 22.7 150 13 0.874 4.0 ---- 13.0 ---- ---- 0.13 0.00 21.9 ---- 0.13 0.00 21.9 11 13 12.50 LR ---- 13.0 ---- ---- 15.5 2.30 21.9 ---- 15.6 2.30 21.9 150 14 0.874 5.0 ---- 13.0 ---- ---- 0.13 0.00 19.6 ---- 0.13 0.00 19.6 12 14 4.50 B ---- 13.0 ---- ---- 20.0 1.57 19.6 ---- 20.0 1.57 19.6 150 15 0.874 3.0 ---- 13.0 4.71 20.0 0.21 0.00 18.0 20.0 0.21 0.00 18.0 27 14 22.00 B3R ---- 13.0 ---- ---- -4.5 0.36 19.6 ---- -4.5 0.36 19.6 150 16 0.874 6.0 ---- 13.0 ---- ---- -0.01 0.00 20.0 ---- -0.01 0.00 20.0 13 16 2.00 L ---- 13.0 ---- ---- -4.5 0.08 20.0 ---- -4.5 0.08 20.0 150 17 0.874 4.0 ---- 13.0 ---- ---- -0.01 0.00 20.0 ---- -0.01 0.00 20.0 14 17 33.00 L7R ---- 13.0 ---- ---- -4.5 0.57 20.0 ---- -4.5 0.57 20.0 150 18 0.874 11.0 ---- 11.0 ---- ---- -0.01 0.87 21.5 ---- -0.01 0.87 21.5 15 18 14.50 4R ---- 11.0 ---- ---- -4.5 0.24 21.5 - -- -4.5 0.24 21.5 150 19 0.874 4.0 ---- 11.0 ---- ---- -0.01 0.00 21.7 ---- -0.01 0.00 21.7 16 19 2.00 L ---- 11.0 ---- ---- -4.5 0.08 21.7 ---- -4.5 0.08 21.7 DATE: 11/16/2018 S:\2017\31630\CALCS\4154.rdf Page 3 150 20 0.874 4.0 ---- 13.0 ---- ---- -0.01 0.87 20.9 _--- -0.01 0.87 20.9 17 150 20 21 18.50 0.874 LB3R ---- 10.0 13.0 ---- ---- -4.5 0.37 20.9 ---- -4.5 0.37 20.9 ---- 13.0 ---•- ---- -0.01 0.00 21.3 ---- -0.01 0.00 21.3 18 150 21 22 3.00 0.874 B ---- 3.0 13.0 ---- ---- 0.0 0.00 21.3 ---- 0.0 0.00 21.3 ---- 13.0 ---- ---- 0.00 0.00 21.3 ---- 0.00 0.00 21.3 19 150 21 23 16.00 0.874 2LR 9.0 13.0 --••- ---- -4.5 0.32 21.3 ---- -4.5 0.32 21.3 ---- 13.5 ---- ---- -0.01 0.22 21.4 ---- -0.01 0.22 21.4 28 150 23 24 3.00 0.874 B ---- 3.0 13.5 ---- ---- 0.0 0.00 21.4 ---- 0.0 0.00 21.4 ---- 13.0 ---- ---- 0.00 0.22 21.6 ---- 0.00 0.22 21.6 20 150 23 25 29.00 0.874 3L3R ---- 13.5 ---- ---- -4.5 0.57 21.4 ---- -4.5 0.57 21.4 15.0 ---- 13.0 ---- ---- -0.01 0.22 22.2 --- -0.01 0.22 22.2 21 150 25 26 1.00 0.874 L ---- 4.0 13.0 ---- ---- -4.5 0.06 22.2 ---- -4.5 0.06 22.2 ---- 14.0 ---- ---- -0.01 0.43 21.8 ----• -0.01 0.43 21.8 22 150 26 27 28.50 0.874 L4R --- 14.0 ---- ---- -4.5 0.47 21.8 ---- -4.5 0.47 21.8 8.0 ---- 14.0 ---- ---- -0.01 0.00 22.3 ---- -0.01 0.00 22.3 23 150 27 28 1.00 0.874 L ---- 14.0 ---- ---- -4.5 0.06 22.3 ---- -4.5 0.06 22.3 4.0 ---- 13.0 --•-- ---- -0.01 0.43 22.8 ---- -0.01 0.43 22.8 24 150 28 29 14.00 0.874 L2R ---- 13.0 ---- ---- -4.5 0.26 22.8 ---- -4.5 0.26 22.8 6.0 ---- 13.0 ---- ---- -0.01 0.00 23.1 ---- -0.01 0.00 23.1 25 150 29 30 2.00 0.874 L ---- 4.0 13.0 ---- ---- -4.5 0.08 23.1 ---- -4.5 0.08 23.1 ---- 11.0 ---- ---- -0.01 0.87 24.0 ---- -0.01 0.87 24.0 26 150 30 11 13.00 0.874 LBR ---- 11.0 ---- ---- -4.5 0.27 24.0 ---- -4.5 0.27 24.0 8.0 ---- 11.0 ---- ---- -0.01 0.00 24.3 ---- -0.01 0.00 24.3 Node Notes Pipe Notes Legend: P - Pipe # LEN - Pipe Length DIA - Pipe Diameter FIT. - Pipe Fittings EQV. LN - Pipe Equivalent Length FIXD LOSS - Fixed Loss Device PUMP - Pump Pressure EL - Node Elevation SP - K-Factor DISCH - Discharge in gpm FLOW PF - Flow Rate FL/FT - Friction Loss per Foot - Pressure Loss due to Friction PE - Pressure Loss due to Elevation PT - Total Pressure at Node Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X, y= Y. DATE: 11/16/2018 S:\2017\31630\CALLS\4154.rdf Page 4 The maximum velocity of water flow occurs in pipe 12 at 10.70 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 12 at 10.70 ft/s with 1 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt PAGE: C MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.874 1.00 4.00 3.00 1.00 1.00 5.00 2.00 0.00 0.00 0.00 1.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 1.394 2.00 6.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00 PAGE: K MATERIAL: Copper Tube-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.995 1.00 2.00 6.00 2.00 2.00 6.00 0.00 0.00 0.00 0.00 PAGE: L MATERIAL: Copper Tube-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun. Couplg SwgChk GatVly X Y Z 1.265 1.00 3.00 6.00 2.00 2.00 7.00 0.00 0.00 0.00 0.00 PAGE: P MATERIAL: PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.360 2.00 8.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00 sprinkler system has been hydraulically calculated with the HASS HOUSE 3.8.0 computer program (License No. 50081444 ) to provide an average imbalance of 0..010 gpm at each node and a maximum imbalance of 0.09 gpm with one sprinkler flowing, and. 0.010 gpm at each node and maximum imbalance Of 0.01 gpm with 1 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure of 51.0 psi and a 7 minute flow of 175 gal. and a 10 minute flow of 250.0 gallons. The minimum pressure at any node is 18.0 psi at node 15. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 DATE: 11/16/2018 S:\2017\31630\CALLS\4154.rdf Page 1 FIRE SPRINKLER SYSTEMS 705 E. HARRISON, SUITE 200 CORONA,CA 92879 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR GRIFFIN RANCH LA QUINTA, CA PLAN 4154 10% TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN CALC AREA 2 Date: 11/16/2018 File No: 31630 Data File Name: 4154.rdf SPRINKLER SPACING 256.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 16.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 8.0 ft. SPRINKLER SPECIFICATIONS Mfr: Reliable Descr: RA0616 RFC49 F1 Conc .Pend.(16xl6) K=4.90 Calculated K Factor for Arm-Overs & Drops: 1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee) 0.0 ft. x 0.874 in. Arm -Over: K=4.67 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 74.5 psi Resid: 67.3 psi F1ow:2300.0 gpm Public Main Size: 8 in Domestic Demand: 5.0 gpm at node number 104 SPRINKLER DEMAND No.Spklrs_ Min Spklr. Press. Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 13.0 7.6 22 18.0 74.5 33.2 2 13.0 7.6 22 31.0 74.5 57.2 REVIEWING AUTHORITY CITY OF LA QUINTA FIRE DEPT. DATE: 11/16/2018 S:\2017\31630\CALCS\4154.rdf Page 2 RESULTS OF ANALYSIS PIPE & NODE DATA * FLOW ANALYSIS * 1 sprinkler flowing * 2 sprinklers flowing FIXD P # END LEN FIT. LOSS EL SP *DISCH FLOW PF PT *DISCH FLOW PF PT HWC NOD DIA EQV.LN PUMP (FT) (K) *(GPM) FL/FT PE (PSI)*(GPM) FL/FT PE (PSI) 1 100 30.00 BG ---- -2.0 SRCE ---- 18.0 3.29 33.2 ---- 31.0 9.00 57.2 150 101 0.995 6.0 ---- -2.0 ---- ---- 0.09 0.00 29.9 ---- 0.25 0.00 48.2 2 101 1.00 -4.0 -2.0 ---- ---- 18.0 0.09 29.9 ---- 31.0 0.25 48.2 150 102 0.995 0.0 ---- -2.0 ---- ---- 0.09 0.00 25.8 ---- 0.25 0.00 43.9 3 102 70.00 3L ---- -2.0 ---- ---- 18.0 1.88 25.8 ---- 31.0 5.14 43.9 150 103 1.360 24.0 ---- -2.0 ---- ---- 0.02 0.00 23.9 ---- 0.05 0.00 38.8 4 103 4.00 LG ---- -2.0 ---- ---- 18.0 0.20 23.9 ---- 31.0 0.55 38.8 150 104 1.265 3.0 ---- 2.0 -5 5 0.03 1.73 22.0 5 0.08 1.73 36.5 5 104 2.00 L ---- 2.0 -5 5 13.0 0.08 22.0 5 26.0 0.28 36.5 150 105 1.394 6.0 ---- 4.0 ---- ---- 0.01 0.87 21.0 ---- 0.04 0.87 35.4 6 105 1.00 -3.0 4.0 ---- ---- 13.0 0.01 21.0 ---- 26.0 0.04 35.4 150 106 1.394 0.0 ---- 4.0 ---- ---- 0.01 0.00 18.0 ---- 0.04 0.00 32.3 7 106 7.00 2L ---- 4.0 ---- ---- 13.0 0.18 18.0 ---- 26.0 0.67 32.3 150 10 1.394 12.0 ---- 11.0 ---- ---- 0.01 3.03 14.8 ---- 0.04 3.03 28.6 8 10 35.50 2L5R ---- 11.0 ---- -•-- 13.0 1.55 14.8 ---- 26.0 5.58 28.6 150 11 1.101 15.0 ---- 11.0 ---- ---- 0.03 0.00 13.3 ---- 0.11 0.00 23.0 9 11 4.50 R ---- 11.0 ---- ---- 6.5 0.15 13.3 -- - 12.5 0.48 23.0 150 12 0.874 1.0 ---- 13.0 ---- ---- 0.03 0.87 12.3 -- - 0.09 0.87 21.7 10 12 2.00 L ---- 13-0 ---- ---- 6.5 0.16 12.3 ---- 12.5 0.52 21.7 150 13 0.874 4.0 ---- 13-0 - - ---- 0.03 0.00 12.1 ---- 0.09 0.00 21.2 11 13 12.50 LR ---- 13.0 ---- ---- 6.5 0.46 12.1 - -- 12.5 1.53 21.2 150 14 0.874 5.0 ---- 13.0 ---- ---- 0.03 0.00 11.6 - -- 0.09 0.00 19.6 12 14 4.50 B ---- 13.0 ---- ---- 0.0 0.00 11.6 ---- 0.0 0.00 19.6 150 15 0.874 3.0 ---- 13.0 ---- ---- 0.00 0.00 11.6 ---- 0.00 0.00 19.6 27 14 22.00 B3R ---- 13.0 - -- ---- 6.5 0.74 11.6 ---- 12.5 2.45 19.6 150 16 0.874 6.0 -_-- 13.0 - • -- ---- 0.03 0.00 10.9 ---- 0.09 0.00 17.2 13 16 2.00 L ---- 13.0 ---- ---- 6.5 0.16 10.9 ---- 12.5 0.52 17.2 150 17 0.874 4.0 -- - 13.0 ---- ---- 0.03 0.00 10.7 ---- 0.09 0.00 16.7 14 17 33.00 L7R -- - 13.0 ---- ---- 6.5 1.16 10.7 ---- 12.5 3.85 16.7 150 18 0.874 11.0 ---- 11.0 ---- ---- 0.03 0.87 10.4 ---- 0.09 0.87 13.7 15 18 14.50 4R ---- 11.0 ---- ---- 6.5 0.49 10.4 ---- 12.5 1.62 13.7 150 19 0.874 4.0 ---- 11.0 --- ---- 0.03 0.00 10.0 ---- 0.09 0.00 12.1 16 19 2.00 L ---- 11.0 ---- ---- 6.5 0.16 10.0 ---- 12.5 0.52 12.1 DATE: 11/16/2018 S:\2017\31630\CALCS\4154.rdf Page 3 150 20 0.874 4.0 ---- 13.0 ---- ---- 0.03 0.87 8.9 ---- 0.09 0.87 10.7 17 20 18.50 LB3R ---- 13.0 ---- ---- 6.5 0.75 8.9 ---- 12.5 2.49 10.7 150 21 0.874 10.0 ---- 13.0 ---- ---- 0.03 0.00 8.2 ---- 0.09 0.00 8.2 18 21 3.00 B ---- 13.0 ---- ---- 13.0 0.57 8.2 ---- 13.0 0.57 8.2 150 22 0.874 3.0 ---- 13.0 4.71 13.0 0.09 0.00 7.6 13.0 0.09 0.00 7.6 19 21 16.00 2LR ---- 13.0 ---- ---- -6.5 0.65 8.2 ---- -0.5 0.01 8.2 150 23 0.874 9.0 ---- 13.5 ---- ---- -0.03 0.22 8.6 ---- 0.00 0.22 8.0 28 23 3.00 B ---- 13.5 ---- ---- 0.0 0.00 8.6 ---- 13.0 0.57 8.0 150 24 0.874 3.0 -- - 13.0 4.71 ---- 0.00 0.22 8.8 13.0 0.09 0.22 7.6 20 23 29.00 3L3R ---- 13.5 ---- ---- -6.5 1.14 8.6 ---- -13.5 4.47 8.0 150 25 0.874 15.0 ---- 13.0 ---- ---- -0.03 0.22 10.0 --- -0.10 0.22 12.7 21 25 1.00 L ---- 13.0 ---- ---- -6.5 0.13 10.0 ---- -13.5 0.51 12.7 150 26 0.874 4.0 ---- 14.0 ---- ---- -0.03 0.43 9.7 ---- -0.10 0.43 12.7 22 26 28.50 L4R ---- 14.0 ---- ---- -6.5 0.95 9.7 ---- -13.5 3.71 12.7 150 27 0.874 8.0 ---- 14.0 ---- ---- -0.03 0.00 10.6 ---- -0.10 0.00 16.5 23 27 1.00 L ---- 14.0 ---- ---- -6.5 0.13 10.6 ---- -13.5 0.51 16.5 150 28 0.874 4.0 ---- 13.0 ---- ---- -0.03 0.43 11.2 ---- -0.10 0.43 17.4 24 28 14.00 L2R ---- 13.0 ---- ---- -6.5 0.52 11.2 ---- -13.5 2.03 17.4 150 29 0.874 6.0 ---- 13.0 ---- ---- -0.03 0.00 11.7 ---- -0.10 0.00 19.4 25 29 2.00 L ---- 13.0 ---- ---- -6.5 0.16 11.7 - -- -13.5 0.61 19.4 150 30 0.874 4.0 ---- 11.0 ---- ---- -0.03 0.87 12.7 ---- -0.10 0.87 20.9 26 30 13.00 LBR - -- 11.0 ---- ---- -6.5 0.55 12.7 -_-- -13.5 2.14 20.9 150 11 0.874 8.0 ---- 11.0 ---- ---- -0.03 0.00 13.3 - -- -0.10 0.00 23.0 Node Notes Pipe Notes Legend: P - Pipe # LEN - Pipe Length DIA - Pipe Diameter FIT. - Pipe Fittings EQV. LN - Pipe Equivalent Length FIXD LOSS - Fixed Loss Device PUMP - Pump Pressure EL - Node Elevation SP - K-Factor DISCH - Discharge in gpm FLOW - Flow Rate FL/FT - Friction Loss per Foot PF - Pressure Loss due to Friction PE - Pressure Loss due to Elevation PT - Total Pressure at Node Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X, Y= Y, DATE: 11/16/2018 S:\2017\31630\CALCS\4154.rdf Page 4 The maximum velocity of water flow occurs in pipe 2 at 7.43 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 2 at 12.79 ft/s with 2 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt PAGE: C MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.874 1.00 4.00 3.00 1.00 1.00 5.00 2.00 0.00 0.00 0.00 1.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 1.394 2.00 6.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00 PAGE: K MATERIAL: Copper Tube-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet' (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.995 1.00 2.00 6.00 2.00 2.00 6.00 0.00 0.00 0.00 0.00 PAGE: L MATERIAL: Copper Tube-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.265 1.00 3.00 6.00 2.00 2.00 7.00 0.00 0.00 0.00 0.00 PAGE: P MATERIAL: PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.360 2.00 8.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.8.0 computer program (License No. 50081444 ) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.15 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.18 gpm with 2 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure of 57.2 psi and a 7 minute flow of 217 gal. and a 10 minute flow of 310.1 gallons. The minimum pressure at any node is 7.6 psi at node 22. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 DATE: 11/16/2018 S:\2017\31630\CALCS\4154.rdf Page 5 WATER SUPPLY CURVE 75.0 H C 67.5 P 60.0 R E 52.5 S S 45.0 U R I E 37.5 { 30.0 P 22.5 S I 15.0 i 7.5 0.0 -, , 1 1 04 8 12 16 20 24 28 FLOW (GPM) 32 36 40 Static = 74.5 psi, Residual = 67.3 psi @ 2300 gpm (1 sprinkler flowing) (2 sprinklers flowing) A = Available Water Supply C = Available Water Supply 74.5 psi @ 18.0 gpm 74.5 psi @ 31.0 gpm B = Required Water Supply D = Required Water Supply 33.2 psi @ 18.0 gpm 57.2 psi @ 31.0 gpm DATE: 11/16/2018 S:\2017\31630\CALLS\4154.rdf Page 6 DATE: 11/16/2018 S:\2017\31630\CALLS\4154_ALT.rdf Page 1 FIRE SPRINKLER SYSTEMS 705 E. HARRISON, SUITE 200 CORONA,CA 92879 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR GRIFFIN RANCH LA QUINTA, CA PLAN 4154 ALT. 10% TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN CALC AREA 1 Date: 11/16/2018 File No: 31630 Data File Name: 4154 ALT.rdf SPRINKLER SPACING 400.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 20.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 10.0 ft. SPRINKLER SPECIFICATIONS Mfr: Reliable Descr: RA0616 RFC49 Fl Conc .Pend.(20x2O) K=4.90 Calculated K Factor for Arm-Overs & Drops: 1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee) 0.0 ft. x 0.874 in. Arm -Over: K=4.67 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 74.5 psi Resid: 67.3 psi F1ow:2300.0 gpm Public Main Size: 8 in Domestic Demand: 5.0 gpm at node number 104 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press. Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 20.0 18.0 15 25.0 74.5 57.0 1 20.0 18.0 15 25.0 74.5 57.0 REVIEWING AUTHORITY CITY OF LA QUINTA FIRE DEPT. DATE: 11/16/2018 S:\2017\31630\CALCS\4154-ALT.rdf Page 2 RESULTS OF ANALYSIS PIPE & NODE DATA * FLOW ANALYSIS * 1 sprinkler flowing * 1 sprinklers flowing FIXD P # END LEN FIT. LOSS EL SP *DISCH FLOW PF PT *DISCH FLOW PF PT HWC NOD DIA EQV.LN PUMP (FT) (K) *(GPM) FL/FT PE (PSI)*(GPM) FL/FT PE (PSI) 1 100 30.00 BG ---- -2.0 SRCE ---- 25.0 6.06 57.0 ---- 25.0 6.05 57.0 150 101 0.995 6.0 ---- -2.0 ---- ---- 0.17 0.00 51.0 ---- 0.17 0.00 51.0 2 101 1.00 -9.5 -2.0 ---- ---- 25.0 0.69 51.0 ---- 25.0 0.69 51.0 150 102 0.745 0.0 ---- -2.0 ---- ---- 0.69 0.00 40.8 ---- 0.69 0.00 40.8 3 102 70.00 3L ---- -2.0 ---- ---- 25.0 3.45 40.8 ---- 25.0 3.45 40.8 150 103 1.360 24.0 ---- -2.0 ---- ---- 0.04 0.00 37.3 ---- 0.04 0.00 37.3 4 103 4.00 LG ---- -2.0 ---- ---- 25.0 0.37 37.3 ---- 25.0 0.37 37.3 150 104 1.265 3.0 - - 2.0 -5 5 0.05 1.73 35.2 5 0.05 1.73 35.2 5 104 2.00 L ---- 2.0 -5 5 20.0 0.17 35.2 5 20.0 0.17 35.2 150 105 1.394 6.0 ---- 4.0 ---- ---- 0.02 0.87 34.2 ---- 0.02 0.87 34.2 6 105 1.00 -3.0 4.0 ---- ---- 20.0 0.02 34.2 ---- 20.0 0.02 34.2 150 106 1.394 0.0 ---- 4.0 ---- ---- 0.02 0.00 31.2 --- 0.02 0.00 31.2 7 106 7.00 2L ---- 4.0 ---- ---- 20.0 0.41 31.2 ---- 20.0 0.41 31.2 150 10 1.394 12.0 ---- 11.0 ---- ---- 0.02 3.03 27.7 ---- 0.02 3.03 27.7 8 10 35.50 2L5R ---- 11.0 ---- ---- 20.0 3.44 27.7 ---- 20.0 3.43 27.7 150 11 1.101 15.0 ---- 11.0 ---- ---- 0.07 0.00 24.3 ---- 0.07 0.00 24.3 9 11 4.50 R ---- 11.0 ---- ---- 15.6 0.72 24.3 ---- 15.5 0.72 24.3 150 12 0.874 1.0 ---- 13.0 ---- ---- 0.13 0.87 22.7 ---- 0.13 0.87 22.7 10 12 2.00 L ---- 13.0 ---- ---- 15.6 0.79 22.7 ---- 15.5 0.79 22.7 150 13 0.874 4.0 ---- 13.0 ---- --- 0.13 0.00 21.9 ---- 0.13 0.00 21.9 11 13 12.50 LR ---- 13.0 ---- ---- 15.6 2.30 21.9 ---- 15.5 2.30 21.9 150 14 0.874 5.0 ---- 13.0 ---- ---- 0.13 0.00 19.6 ---- 0.13 0.00 19.6 12 14 4.50 B ---- 13.0 ---- ---- 20.0 1.57 19.6 ---- 20.0 1.57 19.6 150 15 0.874 3.0 ---- 13.0 4.71 20.0 0.21 0.00 18.0 20.0 0.21 0.00 18.0 27 14 22.00 B3R ---- 13.0 ---- ---- -4.5 0.36 19.6 ---- -4.5 0.36 19.6 150 16 0.874 6.0 ---- 13.0 ---- ---- -0.01 0.00 20.0 ---- -0.01 0.00 20.0 13 16 2.00 L ---- 13.0 ---- ---- -4.5 0.08 20.0 ---- -4.5 0.08 20.0 150 17 0.874 4.0 ---- 13.0 ---- ---- -0.01 0.00 20.0 ---- -0.01 0.00 20.0 14 17 33.00 L7R ---- 13.0 - -- ---- -4.5 0.57 20.0 ---- -4.5 0.57 20.0 150 18 0.874 11.0 ---- 11.0 ---- ---- -0.01 0.87 21.5 ---- -0.01 0.87 21.5 15 18 14.50 4R -- - 11.0 ---- ---- -4.5 0.24 21.5 ---- -4.5 0.24 21.5 150 19 0.874 4.0 ---- 11.0 ---- ---- -0.01 0.00 21.7 ---- -0.01 0.00 21.7 16 19 2.00 L ---- 11.0 ---- ---- -4.5 0.08 21.7 ---- -4.5 0.08 21.7 DATE: 11/16/2018 S:\2017\31630\CALCS\4154_ALT.rdf Page 3 150 20 0.874 4.0 ---- 13.0 ---- ---- -0.01 0.87 20.9 ---- -0.01 0.87 20.9 17 20 18.50 150 21 0.874 LB3R ---- 10.0 13.0 ---- ---- -4.5 0.37 20.9 -- -- -4.5 0.37 20.9 ---- 13.0 ---- ---- -0.01 0.00 21.3 ---- -0.01 0.00 21.3 18 150 21 22 3.00 0.874 B ---- 3.0 13.0 ---- ---- 0.0 0.00 21.3 _ --- 0.0 0.00 21.3 ---- 13.0 ---- ---- 0.00 0.00 21.3 ---- 0.00 0.00 21.3 19 150 21 23 16.00 0.874 2LR ---- 13.0 ---- ---- -4.5 0.32 21.3 _ --- -4.5 0.32 21.3 g•p ___ - 13.5 ---•- ---- -0.01 0.22 21.4 ---- -0.01 0.22 21.4 28 150 23 24 3.00 0.874 B ---- 3.0 13.5 ---- ---- 0.0 0.00 21.4 -- - 0.0 0.00 21.4 ---- 13.0 ---- ---- 0.00 0.22 21.6 ---- 0.00 0.22 21.6 20 150 23 25 29.00 0.874 3L3R ---- 15.0 13.5 ---- ---- -4.5 0.57 21.4 - -`- -4.5 0.57 21.4 ---•• 13.0 ---- ---- -0.01 0.22 22.2 ---- -0.01 0.22 22.2 21 150 25 26 1.00 0.874 L ---- 4.0 13.0 ---- ---- -4.5 0.06 22.2 ---- -4.5 0.06 22.2 ---- 14.0 ---- ---- -0.01 0.43 21.8 - ---0.01 0.43 21.8 22 150 26 27 28.50 0.874 L4R ---- 8.0 14.0 ---- ---- -4.5 0.47 21.8 ---- -4.5 0.47 21.8 ---- 14.0 ---- ---- -0.01 0.00 22.3 --- -0.01 0.00 22.3 23 150 27 28 1.00 0.874 L ---- 4.0 14.0 ---- ---- -4.5 0.06 22.3 - --- -4.5 0.06 22.3 - 13.0 ---- ---- -0.01 0.43 22.8 ---- -0.01 0.43 22.8 24 150 28 29 14.00 0.874 L2R ---- 6,0 13.0 ---- ---- -4.5 0.26 22.8 - --- -4.5 0.26 22.8 -_ -- 13.0 ---- ---- -0.01 0.00 23.1 ---- -0.01 0.00 23.1 25 150 29 30 2.00 0.874 L --- 4.0 13.0 ---- ---- -4.5 0.08 23.1 ---- -4.5 0.08 23.1 --- 11.0 ---- ---- -0.01 0.87 24.0 ---- -0.01 0.87 24.0 26 150 30 11 13.00 0.874 LBR ---- 8-0 11.0 ---- ---- -4.5 0.27 24.0 --•- -4.5 0.27 24.0 ---- 11.0 ---- ---- -0.01 0.00 24.3 ---- -0.01 0.00 24.3 Node Notes Pipe Notes Legend: P - DIA Pipe # - Pipe Diameter LEN - Pipe Length EQV. LN - Pipe Equivalent Length FIT. FIXD - Pipe Fittings LOSS - Fixed PUMP - Pump Pressure EL - Loss Device Node Elevation SP - FLOW K-Factor - Flow Rate DISCH - Discharge in gpm PF - Pressure Loss due to Friction FL/FT PE - - Friction Loss per Foot Pressure PT - Total Pressure at Node Loss due to Elevation Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X, Y= Y, DATE: 11/16/2018 S:\2017\31630\CALLS\4154_ALT.rdf Page 4 The maximum velocity of water flow occurs in pipe 2 at 18.40 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 2 at 18.40 ft/s with 1 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt PAGE: C MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet ( in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.874 1.00 4.00 3.00 1.00 1.00 5.00 2.00 0.00 0.00 0.00 1.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 1.394 2.00 6.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00 PAGE: K MATERIAL: Copper Tube-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 0.745 0.00 1.00 3.00 1.00 1.00 0.00 0.00 0.00 0.00 0.00 0.995 1.00 2.00 6.00 2.00 2.00 6.00 0.00 0.00 0.00 0.00 PAGE: L MATERIAL: Copper Tube-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.265 1.00 3.00 6.00 2.00 2.00 7.00 0.00 0.00 0.00 0.00 PAGE: P MATERIAL: PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.360 2.00 8.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.8.0 computer program (License No. 50081444 ) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.01 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.05 gpm with 1 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure of 57.0 psi and a 7 minute flow of 175 gal. and a 10 minute flow of 250.0 gallons. The minimum pressure at any node is 18.0 psi at node 15. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 DATE: 11/16/2018 S:\2017\31630\CALCS\4154..ALT.rdf Page 5 WATER SUPPLY CURVE 75.0�- C 67.5 P 60.0 R OD E 52.5� S S 45.Or U R 37.5� E { 30.0 P 22.5 S I } 15.0 7.5 0.0 04 8 12 16 20 24 28 32 36 40 FLOW (GPM) Static = 74.5 psi, Residual = 67.3 psi @ 2300 gpm (1 sprinkler flowing) (1 sprinklers flowing) A = Available Water Supply C = Available Water Supply 74.5 psi @ 25.0 gpm 74.5 psi @ 25.0 gpm B = Required Water Supply D = Required Water Supply 57.0 psi @ 25.0 gpm 57.0 psi @ 25.0 gpm DATE: 11/16/2018 S:\2017\31630\CALCS\4154-ALT.rdf Page 6 DATE: 11/16/2018 S:\2017\31630\CALCS\4154-ALT.rdf Page 1 FIRE SPRINKLER SYSTEMS 705 E. HARRISON, SUITE 200 CORONA,CA 92879 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR GRIFFIN RANCH LA QUINTA, CA PLAN 4154 ALT. 10%- TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN CALC AREA 2 Date: 11/16/2018 File No: 31630 Data File Name: 4154 ALT.rdf SPRINKLER SPACING 256.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 16.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 8.0 ft. SPRINKLER SPECIFICATIONS Mfr: Reliable Descr: RA0616 RFC49 F1 Conc .Pend.(16x16) K=4.90 Calculated K Factor for Arm-Overs & Drops: 1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee) 0.0 ft. x 0.874 in. Arm -Over: K=4.67 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 74.5 psi Resid: 67.3 psi F1ow:2300.0 gpm Public Main Size: 8 in Domestic Demand: 5.0 gpm at node number 104 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press Flowing Flow (psi) 1 13.0 7.6 2 13.0 7.6 REVIEWING AUTHORITY CITY OF LA QUINTA FIRE DEPT. Node Total Avail. Req'd No. Flow Press. Press. 22 18.0 74.5 39.0 22 31.0 74.5 63.5 DATE: 11/16/2018 S:\2017\31630\CALCS\4154-ALT.rdf Page 2 RESULTS OF ANALYSIS PIPE & NODE DATA * FLOW ANALYSIS * 1 sprinkler flowing * 2 sprinklers flowing FIXD P # END LEN FIT. LOSS EL SP *DISCH FLOW PF PT *DISCH FLOW PF PT HWC NOD DIA EQV.LN PUMP (FT) (K) *(GPM) FL/FT PE (PSI)*(GPM) FL/FT PE (PSI) 1 100 30.00 BG ---- -2.0 SRCE ---- 18.0 3.28 39.0 ---- 31.0 9.01 63.5 150 101 0.995 6.0 ---- -2.0 ---- ---- 0.09 0.00 35.7 ---- 0.25 0.00 54.4 2 101 1.00 -9.5 -2.0 ---- ---- 18.0 0.38 35.7 ---- 31.0 1.03 54.4 150 102 0.745 0.0 ---- -2.0 ---- ---- 0.38 0.00 25.8 ---- 1.03 0.00 43.9 3 102 70.00 3L --- -2.0 ---- ---- 18.0 1.88 25.8 ---- 31.0 5.14 43.9 150 103 1.360 24.0 ---- -2.0 ---- ---- 0.02 0.00 23.9 --- 0.05 0.00 38.8 4 103 4.00 LG ---- -2.0 ---- ---- 18.0 0.20 23.9 ---- 31.0 0.54 38.8 150 104 1.265 3.0 ---- 2.0 ••5 5 0.03 1.73 22.0 5 0.08 1.73 36.5 5 104 2.00 L ---- 2.0 -5 5 13.0 0.08 22.0 5 26.0 0.28 36.5 150 105 1.394 6.0 ---- 4.0 ---- ---- 0.01 0.87 21.1 ---- 0.04 0.87 35.4 6 105 1.00 -3.0 4.0 ---- ---- 13.0 0-01 21.1 ---- 26.0 0.04 35.4 150 106 1.394 0.0 ---- 4.0 ---- ---- 0.01 0.00 18.0 ---- 0.04 0.00 32.3 7 106 7.00 2L ---- 4.0 ---- ---- 13.0 0.18 18.0 --- 26.0 0.67 32.3 150 10 1.394 12.0 ---- 11.0 ---- ---- 0.01 3.03 14.8 ---- 0.04 3.03 28.6 8 10 35.50 2L5R ---- 11.0 ---- ---- 13.0 1.55 14.8 ---- 26.0 5.58 28.6 150 11 1.101 15.0 ---- 11.0 ---- ---- 0.03 0.00 13.3 ---- 0.11 0.00 23.0 9 11 4.50 R ---- 11.0 ---- ---- 6.5 0.15 13.3 ---- 12.5 0.48 23.0 150 12 0.874 1.0 ---- 13.0 ---- ---- 0.03 0.87 12.3 ---- 0.09 0.87 21.7 10 12 2.00 L ---- 13.0 ---- --- 6.5 0.16 12.3 ---- 12.5 0.52 21.7 150 13 0.874 4.0 ---- 13.0 ---- ---- 0.03 0.00 12.1 ---- 0.09 0.00 21.2 11 13 12.50 LR ---- 13.0 ---- ---- 6.5 0.46 12.1 ---- 12.5 1.53 21.2 150 14 0.874 5.0 ---- 13.0 ---- ---- 0.03 0.00 11.6 ---- 0.09 0.00 19.6 12 14 4.50 B --- 13.0 ---- ---- 0.0 0.00 11.6 ---- 0.0 0.00 19.6 150 15 0.874 3.0 ---- 13.0 ---- ---- 0.00 0.00 11.6 ---- 0.00 0.00 19.6 27 14 22.00 B3R ---- 13.0 ---- ---- 6.5 0.74 11.6 ---- 12.5 2.45 19.6 150 16 0.874 6.0 ---- 13.0 ---- ---- 0.03 0.00 10.9 ---- 0.09 0.00 17.2 13 16 2.00 L ---- 13.0 ---- ---- 6.5 0.16 10.9 ---- 12.5 0.52 17.2 150 17 0.874 4.0 ---- 13.0 ---- ---- 0.03 0.00 10.7 ---- 0.09 0.00 16.7 14 17 33.00 L7R ---- 13.0 ---- ---- 6.5 1.16 10.7 ---- 12.5 3.85 16.7 150 18 0.874 11.0 ---- 11.0 ---- ---- 0.03 0.87 10.5 ---- 0.09 0.87 13.7 15 18 14.50 4R ---- 11.0 ---- ---- 6.5 0.49 10.5 ---- 12.5 1.62 13.7 150 19 0.874 4.0 ---- 11.0 ---- ---- 0.03 0.00 10.0 ---- 0.09 0.00 12.1 16 19 2.00 L ---- 11.0 ---- ---- 6.5 0.16 10.0 ---- 12.5 0.52 12.1 DATE: 11/16/2018 S:\2017\31630\CALCS\4154_ALT.rdf Page 3 150 20 0.874 4.0 ---- 13.0 ---- ---- 0.03 0.87 8.9 ---- 0.09 0.87 10.7 17 20 18.50 LB3R - -- 13.0 ---- ---- 6.5 0.75 8.9 ---- 12.5 2.49 10.7 150 21 0.874 10.0 ---- 13.0 ---- ---- 0.03 0.00 8.2 ---- 0.09 0.00 8.2 18 21 3.00 B ---- 13.0 ---- ---- 13.0 0.57 8.2 ---- 13.0 0.57 8.2 150 22 0.874 3.0 ---- 13.0 4.71 13.0 0.09 0.00 7.6 13.0 0.09 0.00 7.6 19 21 16.00 2LR ---- 13.0 ---- ---- -6.5 0.65 8.2 ---- -0.5 0.01 8.2 150 23 0.874 9.0 ---- 13.5 ---- ---- -0.03 0.22 8.6 ---- 0.00 0.22 8.0 28 23 3.00 B ---- 13.5 ---- ---- 0.0 0.00 8.6 ---- 13.0 0.57 8.0 150 24 0.874 3.0 ---- 13.0 4.71 ---- 0.00 0.22 8.8 13.0 0.09 0.22 7.6 20 23 29.00 3L3R ---- 13.5 ---- ---- -6.5 1.14 8.6 ---- -13.5 4.47 8.0 150 25 0.874 15.0 ---- 13.0 ---- ---- -0.03 0.22 10.0 ---- -0.10 0.22 12.7 21 25 1.00 L ---- 13.0 ---- ---- -6.5 0.13 10.0 ---- -13.5 0.51 12.7 150 26 0.874 4.0 ---- 14.0 ---- ---- -0.03 0.43 9.7 ---- -0.10 0.43 12.7 22 26 28.50 L4R ---- 14.0 ---- ---- -6.5 0.95 9.7 ---- -13.5 3.71 12.7 150 27 0.874 8.0 ---- 14.0 ---- ---- -0.03 0.00 10.6 ---- -0.10 0.00 16.4 23 27 1.00 L ---- 14.0 ---- ---- -6.5 0.13 10.6 ---- -13.5 0.51 16.4 150 28 0.874 4.0 ---- 13.0 ---- ---- -0.03 0.43 11.2 ---- -0.10 0.43 17.4 24 28 14.00 L2R ---- 13.0 ---- ---- -6.5 0.52 11.2 ---- -13.5 2.03 17.4 150 29 0.874 6.0 ---- 13.0 ---- ---- -0.03 0.00 11.7 ---- -0.10 0.00 19.4 25 29 2.00 L ---- 13.0 ---- ---- -6.5 0.16 11.7 ---- -13.5 0.61 19.4 150 30 0.874 4.0 --- 11.0 ---- ---- -0.03 0.87 12.7 ---- -0.10 0.87 20.9 26 30 13.00 LBR ---- 11.0 --- ---- -6.5 0.55 12.7 ---- -13.5 2.14 20.9 150 11 0.874 8.0 ---- 11.0 ---- ---- -0.03 0.00 13.3 ---- -0.10 0.00 23.0 Node Notes Pipe Notes Legend: P - Pipe # LEN - Pipe Length DIA - Pipe Diameter FIT. - Pipe Fittings EQV. LN - Pipe Equivalent Length FIXD LOSS - Fixed Loss Device PUMP - Pump Pressure EL - Node Elevation SP - K-Factor DISCH - Discharge in gpm FLOW - Flow Rate FL/FT - Friction Loss per Foot PF - Pressure Loss due to Friction PE - Pressure Loss due to Elevation PT - Total Pressure at Node Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X, Y= Y, DATE: 11/16/2018 S:\2017\31630\CALLS\4154 ALT.rdf Page 4 The maximum velocity of water flow occurs in pipe 2 at 13.25 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 2 at 22.82 ft/s with 2 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt PAGE: C MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X y 0.874 1.101 1.00 4.00 3.00 1.00 1.00 5.00 2.00 0.00 0.00 Z 0.00 1.394 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 2.00 6.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00 PAGE: K MATERIAL: Copper Tube-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X y 0.745 0.995 0.00 1.00 3.00 1.00 1.00 0.00 0.00 0.00 0.00 Z 0.00 1.00 2.00 6.00 2.00 2.00 6.00 0.00 0.00 0.00 0.00 PAGE: L MATERIAL: Copper Tube-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X y Z 1.265 1.00 3.00 6.00 2.00 2.00 7.00 0.00 0.00 0.00 0.00 PAGE: P MATERIAL: PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X y 1.360 2.00 8.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 Z 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.8.0 computer program (License No. 50081444 ) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance ❑f 0.18 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance Of 0.11 gpm with 2 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure of 63.5 psi and a 7 minute flow of 217 gal. and a 10 minute flow of 310.0 gallons. The minimum pressure at any node is 7.6 psi at node 22. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 DATE: 11/16/2018 S:\2017\31630\CALCS\4154 ALT.rdf Page 5 75.0 67.5 P 60.0 R E 52.5 S S 45.0 U R 37.5 E ( 30.0 P S 22.r I ) 15.( 7.5 III WATER SUPPLY CURVE 0D 0.0 04 8 12 16 20 24 28 32 36 FLOW (GPM) Static = 74.5 psi, Residual = 67.3 psi @ 2300 gpm (1 sprinkler flowing) (2 sprinklers flowing) A = Available Water Supply C = Available Water Supply 74.5 psi @ 18.0 gpm 74.5 psi @ 31.0 gpm B = Required Water Supply D = Required Water Supply 39.0 psi @ 18.0 gpm 63.5 psi @ 31.0 gpm 40 DATE: 11/16/2018 S:\2017\31630\CALCS\4154_ALT.rdf Page 6 OFFICE USE ONLY: REVIEW DATE: _ ❑ APPROVED El CORRECTIONS CALIFORNIA CALLED FOR PICKUP: DESIGN & DEVELOPMENT DEPARTMENT 78-495 Calle Tampico PICKED UP: La Quinta, California 92253 (760) 777-7125 / FAX (760) 777-7011 FIRE REVIEW APPLICATION ❑ SUBMITTAL # 0 REVISION # Applicant Name: Mailing Address: APPLICANT/OWNER INFORMATION Dj DATL CIA] I~E 03 13 20IN 1 A Mkf k DESIGN & DEJELUHAN f DEPARTMENT PERMIT NO. FIRE SPRINKLER SYSTEMS, INC Owner Name: LENNAR 705 E. HARRISON ST. #200, CORONA CA 92879 Site Address: ozo - ooaI MASTER PLAN 5(4154) AS -BUILT Phone Number: 951-272-2522 Project PRESTIGE / TRACT# 32879 / PLAN TYPE 5(4154) / 46 HEADS Email: jamieb@fireinc.net Description: (Include # of sprinkler heads) Pursuant to a Cooperative Agreement to Provide Fire Services, the Riverside County Fire Department serves as the City's fire department, and the County designee serves as the City's fire chief. Applicant recognizes this contracted arrangement and shall comply with County Fire Depwiment directions. CONTRACTOR INFORMATION Contractor Name: FIRE SPRINKLER SYSTEMS, INC. Contractor #: 684600 Signature: Contact Person: JAMIE BISHIP ` Mailing Address: 705 E. HARRISON ST., #200 Print Name: JAMIE BISHIP City, State, Zip: CORONA, CA 92879 Phone Number: 951-272-2522 Business License #: 762890 Email Address: jamieb@fireinc.net A. APPLICATION TYPE FIRE SPRINKLER SYSTEM STORAGE TANKS ❑ NEW COMMERCIAL/INDUSTRIAL ❑ DISPENSERS ONLY HOURLY@161/HR ❑ 0-35,000 SQ FT $670 ❑ ABOVE GROUND HOURLY@161/HR ❑ 35,001-75,000 SQ FT $791 SUPRESSION SYSTEM ❑ 75,001-120,000 SQ FT $992 ❑ HOOD & DUCT $418 ❑ 120,001 AND UP $1234 ❑ OTHER SUPRESSION SYSTEM HOURLY@161/HR ❑ TENANT IMPROVEMENTS - FIRE SPRINKLER $418 MASTER PLAN El RESIDENTIAL SPRINKLER SYSTEMS ------------ ❑ MASTER PLAN HOURLY@161/HR ❑ 1-50 SPRINKLER HEADS $418 MISC ❑ 51-100 SPRINKLER HEADS $498 ❑ PYRO $740 ❑ OVER 100 SPRINKLER HEADS $579 ❑ HAZMAT HOURLY@161/HR ❑ RESIDENTIAL TRACT HOME (EA.) ADDITIONAL ❑ HIGH PILE RACK STORAGE HOURLY@161/HR ❑ 1-50 SPRINKLER HEADS $176 ❑ PRIVATE FIRE MAINS $901 ❑ 51-100 SPRINKLER HEADS $257 ❑ TECHNICAL REPORT RESEARCH HOURLY@161/HR ❑ OVER 100 SPRINKLER HEADS $337 ❑ FIRE PUMPS $659 ❑ MULTI -FAMILY (3 OR MORE) 1 $590 ❑ STANDPIPE SYSTEMS $579 FIRE ALARM SYSTEM ❑ WATER TANKS $418 ❑ COMMERCIAL - SPRINKLER MONITORING $418 ❑ REVISION $161 ❑ COMMERCIAL - FIRE ALARM SYSTEM $1062 ❑ OTHER HOURLY@161/HR MI IPF 1. I LYPI I II U— U I _L II JUIUyy Li n wnn n» �eie� ree uI a Kecoras rvlanagemenr ree or >iu or >zi REVISED 12/6/2019 'For permits billed at an hourly rate, these fees will be added at time of payment.