BSOL2022-0579 - Solar PlanMODULE WATT: 425 W(17)LG NEONR PRIME LG425QAK-A6SYSTEM SIZE:7.23 KW DC (STC) :6.65 KW DC (PTC) :6.59 KW AC (CEC)(01)INVERTER: SOLAREDGESE7600H-US(17)POWER OPTIMIZERS:SOLAREDGE P505AZIMUTH:185°ROOF TILT:0°ARRAY TILT:0° ON FLAT ROOFMOUNTING HEIGHT:1-STORYSIGNATURE AND SEALXSTATE LICENSE#LICENSE CLASSC-46EXPIRE DATE02/28/2022RIPPEERESIDENCEJURISDICTIONLA QUINTACITY OFDRAWING INFORMATIONREV#DESCRIPTIONDATEPERMITTINGDRAWNBYREVISIONPROJECT NAME AND ADDRESSDATE:11/11/2021SHEET NAMESHEET NUMBER78761 DEACON DR EASTLOT#26LA QUINTA,CA,92253PHONE:()OCCUPANCY TYPE:V-BGROUP:RAPN:770-230-016BPSUNLOGIX ENERGY77585 ENFIELD LN SUITE APALM DESERT,CA,92211PHONE:760-844-6507CONTRACTOR:ZACHARY N GAMEZ1063414SCOPE OF WORKVICINITY MAPPROJECTSITE(33.67261,-116.28860)CODE COMPLIANCEGENERAL NOTESSHEET INDEX17 x LG NEONR PRIME LG425QAK-A6ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULESSYSTEM SIZE: 7.23 KW DC STC 6.65 KW DC PTC 6.59 KW AC CECEQUIPMENT SUMMARY17 LG NEONR PRIME LG425QAK-A601SOLAREDGE SE7600H-US INVERTER17 SOLAREDGE POWER OPTIMIZERS P505ROOF TILT:0°ARRAY TILT:0° ON FLAT ROOFAZIMUTH:185°1 STORY BUILDING2019 CA BUILDING CODE2019 CA PLUMBING CODE2019 CA FIRE CODE2019 CA RESIDENTIAL CODE2019 CA MECHANICAL CODE2019 CA ENERGY CODE2019 CA ELECTRICAL CODE2017 NATIONAL ELECTRICAL CODE2019 ENERGY COMPLIANCE T-242019 CITY OF LA QUINTA MUNICIPAL CODETHIS PROJECT SHALL COMPLY WITHPV-1 COVER PAGEPV-2 PLOT PLANPV-3 ROOF PLANPV-4 ELECTRICAL LINE DIAGRAMPV-5 ATTACHMENT DETAILPV-6 LIST OF PLACARDSPV-7-12 EQUIPMENTS SPECIFICATIONSUL LISTED FOR ELECTRICAL AND FIRE SAFETYUL 1703 FOR MODULES AND UL 1741 FORINVERTERS PER CITY SOLAR REQUIREMENTSNOTE:NO DISCHARGE OF ANY POLLUTANTS TO ANYSTORM WATER DRAIN SYSTEM-SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE.-THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND LOCAL UTILITY.UTILITY SHALL BENOTIFIED PRIOR TO ACTIVATION OF SOLAR PHOTOVOLTAIC INSTALLATION.-ALL EXTERNAL CONDUIT AND FITTINGS SHALL BE RAIN TIGHT AND SHOULD BE APPROVED TO USE IN WET AND DRY LOCATIONS.-ALL CONDUITS AND EQUIPMENTS SHALL BE PAINTED TO MATCH THE EXISTING BACKGROUND.-THE PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH CBC SECTION 1609 TO WITHSTAND A MINIMUM OF 130 MPH WIND LOAD-DESIGN COMPLYING WITH LATEST EDITION OF CALIFORNIA ELECTRICAL CODE, NEC AND ALL LOCAL ORDINANCES.-SHOULD USE PROPER GROUND BAR AND KITS FOR GROUNDING-THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING. MECHANICAL OR BUILDING ROOF VENTS.-THE DISTANCE BETWEEN BOTTOM OF PANEL TO THE TOP OF ROOF SHOULD BE MIN 4".-BACKFEED BREAKER SHOULD BE AT THE OPPOSITE END OF BUS BAR.-INSTALLERS TO FOLLOW ALL LOCAL JURISDICTION GUIDELINES.-SEE THE SPECS SHEETS FOR ADDITIONAL INFORMATION.-THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ALL THE REQUIREMENTS OF LOCAL UTILITY.-ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC REFERENCES.-A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA .-WORKING DISTANCE AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26.-NO VENTS ( PLUMBING, MECHANICAL OR DORMER) TO BE COVERED OR REROUTED AROUND SOLAR MODULES.RELOCATION TO BE DONE ONLY AFTERAPPROVAL.- ALL LABELS AND PLACARDS SHALL BE ATTACHED ACCORDING TO NEC AND THE LOCAL AHJ.-METAL CONDUIT AND ENCLOSURE SHALL BE USED WHERE PV SOURCE OR OUTPUT CIRCUITS ARE RUN INSIDE THE BUILDING.-ALL OUTDOOR EQUIPMENT SHALL BE MIN NEMA 3R RATED.-PER CALIFORNIA RESIDENTIAL CODE (CRC) SECTIONS R314 AND R315 SMOKE ALARM AND CARBON MONOXIDE DETECTORS ARE RETROFITTED INTO THE EXISTING DWELLINGS.-ALL PHOTOVOLTAIC EQUIPMENT SHALL BE LISTED BY RECOGNIZED TESTING LAB.-ALL SOLAR ENERGY SYSTEMS SHALL MEET APPLICABLE HEALTH AND SAFETY STANDARDS REQUIREMENTS IMPOSED BY THE CITY AND STATE OF CALIFORNIA.-SOLAR ENERGY SYSTEMS FOR PRODUCING ELECTRICITY SHALL MEET ALL APPLICABLE SAFETY AND PERFORMANCE STANDARDS ESTABLISHED BY CALIFORNIA ELECTRICCODE,THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, ACCREDITED TESTING LABORATORIES SUCH AS UNDERWRITER LABORATORIES AND WHEREAPPLICABLE, RULES OF PUBLIC UTILITIES COMMISSION REGARDING SAFETY AND RELIABILITY.SUNLOGIX ENERGY WHO PREPARED AND SIGNED THE PLANS WILL BE INSTALLING THE SYSTEM.BUSINESS AND PROFESSIONAL CODE 5536,5537.2,5537.4 AND 6737.3COVERSHEET STAMPPV1BSOL2022-05797.225kW SOLAR ARRAY - (17)425W LG425QAK-A6 PANELS+ SOLAREDGE P505OPTIMIZERS W/ (1)SOLAREDGE SE7600H-USINVERTER [340SF] 2019CALIFORNIA BUILDINGCODES.07/24/2023
MSPACD
INV JB206'-10"83'-9"
80'-0"136'-9"58'-0"7'±28'±89'±13'±MODULE WATT: 425 W(17)LG NEONR PRIME LG425QAK-A6SYSTEM SIZE:7.23 KW DC (STC) :6.65 KW DC (PTC) :6.59 KW AC (CEC)(01)INVERTER: SOLAREDGESE7600H-US(17)POWER OPTIMIZERS:SOLAREDGE P505AZIMUTH:185°ROOF TILT:0°ARRAY TILT:0° ON FLAT ROOFMOUNTING HEIGHT:1-STORYSIGNATURE AND SEALXSTATE LICENSE#LICENSE CLASSC-46EXPIRE DATE02/28/2022RIPPEERESIDENCEJURISDICTIONLA QUINTACITY OFDRAWING INFORMATIONREV#DESCRIPTIONDATEPERMITTINGDRAWNBYREVISIONPROJECT NAME AND ADDRESSDATE:11/11/2021SHEET NAMESHEET NUMBER78761 DEACON DR EASTLOT#26LA QUINTA,CA,92253PHONE:()OCCUPANCY TYPE:V-BGROUP:RAPN:770-230-016BPSUNLOGIX ENERGY77585 ENFIELD LN SUITE APALM DESERT,CA,92211PHONE:760-844-6507CONTRACTOR:ZACHARY N GAMEZ10634141PLOT PLANSCALE: 1/16"=1'-0"PV2POINT LOAD CALCULATION PERARRAYITEM# OR LN FTWT (LBS)TOTAL WT (LBS)MODULES1741697ROOF RAILS1200.560.0MOUNTS320.516.0MICRO INVERTER/POWEROPTIMIZER174.474.8TOTAL WEIGHT847.8MODULE DIMENSIONS75.19inx41.02in21.4WEIGHT PER MOUNT26.5WEIGHT PER SQ FT(LBS/SQFT)2.3WIND LOAD CALCSMODULES AND RACKING WEIGHT(W)847.8LBSTOTAL MODULES AREA(A)363.8SQFTWIND PRESSURE(PSF) P35PSFL=5/16" DIA LAG SCREWS328LBS/IND=LAG SCREWS EMBEDEMENT2.5INCHQUANTITY OF LAG SCREWS(Q)32QTYWIND SPEED:130 MPHPLOT PLANPV2ROOF AZIMUTH185° FROM NORTHROOF COVERAGEARRAY AREA363.8SQFTROOF AREA7644.0SQFT%COVERAGE4.8%<33ROOF 1:17 MODULESROOF TILT@0°ARRAY TILT@0°AZIMUTH@185°BACKYARDNOTE:FLAT ROOF DOES NOT REQUIRE FIRE SETBACKSSWIMMINGPOOLROOF 1DEACON DR EDRIVE WAY(E)MAIN SERVICE PANEL(N)DG UTILITY AC DISCONNECT(N)INVERTER07/24/2023
MSPACD
INV JB14'-8"37'-8"2'-4"12'-7"
13±3-1/2"
ROOF SLOPE
48" O.C MAX1/3*L MAX TYPEND MOUNTINGCLIP,TYPMID MOUNTINGCLIP,TYPSOLAR STANDARD RAIL TYP1/3*L MAX TYP13±3-1/2"MODULE WATT: 425 W(17)LG NEONR PRIME LG425QAK-A6SYSTEM SIZE:7.23 KW DC (STC) :6.65 KW DC (PTC) :6.59 KW AC (CEC)(01)INVERTER: SOLAREDGESE7600H-US(17)POWER OPTIMIZERS:SOLAREDGE P505AZIMUTH:185°ROOF TILT:0°ARRAY TILT:0° ON FLAT ROOFMOUNTING HEIGHT:1-STORYSIGNATURE AND SEALXSTATE LICENSE#LICENSE CLASSC-46EXPIRE DATE02/28/2022RIPPEERESIDENCEJURISDICTIONLA QUINTACITY OFDRAWING INFORMATIONREV#DESCRIPTIONDATEPERMITTINGDRAWNBYREVISIONPROJECT NAME AND ADDRESSDATE:11/11/2021SHEET NAMESHEET NUMBER78761 DEACON DR EASTLOT#26LA QUINTA,CA,92253PHONE:()OCCUPANCY TYPE:V-BGROUP:RAPN:770-230-016BPSUNLOGIX ENERGY77585 ENFIELD LN SUITE APALM DESERT,CA,92211PHONE:760-844-6507CONTRACTOR:ZACHARY N GAMEZ1063414LEGENDJBINVSUBMSPACD- JUNCTION BOX- INVERTER- AC DISCONNECT- MAIN SERVICE PANEL- SUB PANEL- ATTIC VENTS- DORMER VENTS-SKYLIGHT-CHIMNEY-PRODUCTION METERPMA/C-AIR CONDITON UNIT-SOLAR MODULES-FIRE ACCESS PATHWAYM-ELECTRIC METERCB-COMBINER BOXROOF PLANSCALE: 1/16"=1'-0"PV375.19"41.02"TYPICAL RACK MOUNT LAYOUTSCALE: 3/16"=1'-0"PV3(E)MAIN SERVICE PANELROOF PLANPV3-CONDUIT ON ROOFROOF AZIMUTH185° FROM NORTHLG NEONR PRIMELG425QAK-A612NOTE:MODULES TO BE INSTALLED FLATWITHOUT TILT,INVERTER TO BE LOCATEDINSIDE GARAGE,ALL CONDUIT TO BEINSTALLED INSIDE THE ROOF DECK(N)UTILITY DG AC DISCONNECTDEACON DR E32 QTYATTACHMENTPOINTS @ 48" O.C.MAX2X4 TRUSS@24" O.C TYPE(N)INVERTER(IN GARAGE)ROOF 1:17 MODULESROOF TILT@0°ARRAY TILT@0°AZIMUTH@180°ROOF 107/24/2023
======-+-+-+-+-+-+STRING 1=09 MODULES=7.6 KW SOLAREDGEINVERTER ANDINTEGRATED DCDISCONNECTEQUIPPED WITHRAPID SHUT DOWN25' MAX THWN-23/4" EMTAWG#10POS=REDNED=BLACKAWG#8G=GREENJUNCTION BOX======-+-+-+-+-+-+EGCDC -DCPOWER OPTIMIZERP505STRING 2=08 MODULESPHOTOVOLTAIC ARRAYAWG #10PV WIRE IN FREE AIRPOS = BLACKNEG = WHITEAWG #6G = BARE CU60A RATEDAC DISCONNECT(240 V)NEW, IF NO EXISTINGGROUNDING ELECTRODE(UFER)-#1/0 CUNEW GROUNDROD6' APART MINBOND EXISTING MAINSERVICE PANEL TO COLDWATER PIPEPV BREAKER40 A DPBDEDICATED FOR SOLAR ONLY200 AMAIN DISCONNECT22 KAICBI-DIRECTIONALUTILITY METER1 PHASE, 3 WIRE120/240 VEXISTING400 A RATEDSIEMENSMAIN SERVICEPANELMC3042S1400FC#1/0 CU AS BONDINGJUMPER/SUPPLY SIDEBONDING JUMPER200 ASUB PANEL BREAKERMODULE WATT: 425 W(17)LG NEONR PRIME LG425QAK-A6SYSTEM SIZE:7.23 KW DC (STC) :6.65 KW DC (PTC) :6.59 KW AC (CEC)(01)INVERTER: SOLAREDGESE7600H-US(17)POWER OPTIMIZERS:SOLAREDGE P505AZIMUTH:185°ROOF TILT:0°ARRAY TILT:0° ON FLAT ROOFMOUNTING HEIGHT:1-STORYSIGNATURE AND SEALXSTATE LICENSE#LICENSE CLASSC-46EXPIRE DATE02/28/2022RIPPEERESIDENCEJURISDICTIONLA QUINTACITY OFDRAWING INFORMATIONREV#DESCRIPTIONDATEPERMITTINGDRAWNBYREVISIONPROJECT NAME AND ADDRESSDATE:11/11/2021SHEET NAMESHEET NUMBER78761 DEACON DR EASTLOT#26LA QUINTA,CA,92253PHONE:()OCCUPANCY TYPE:V-BGROUP:RAPN:770-230-016BPSUNLOGIX ENERGY77585 ENFIELD LN SUITE APALM DESERT,CA,92211PHONE:760-844-6507CONTRACTOR:ZACHARY N GAMEZ1063414ELECTRICAL DIAGRAMPV4ELECTRICAL NOTES:1.) ALL EQUIPMENT TO BE LISTED BY UL OR RECOGNIZED TESTING LABORATORY.2.) ALL PLACARDS AND SIGNAGE REQUIRED BY LATEST EDITION OF CEC AND NEC WILL BE INSTALLED AS REQUIRED.3.) ALL THE CONDUIT RUNS SHALL HAVE SUFFICIENT WEATHER PROOF JUNCTION BOXES/COMBINER BOXES.4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC AND CEC5.) ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION AND ALL THE MOUNTING METALLIC EQUIPMENT SHALL BE GROUNDEDACCORDING TO MANUFACTURER INSTRUCTIONS.6.) ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC ENGRAVED OR MACHINE PRINTED LETTER IN A CONTRASTING COLOR .THE PLAQUESHALL BE ATTACHED BY POP RIVETS OR SCREWS OR OTHER APPROVED METHODS AND SHALL BE UV RESISTANT IF EXPOSED TO DIRECT SUNLIGHT.7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE.8.) AL THE PHOTOVOLTAIC SYSTEMS AND REQUIRED WIRINGS SHALL BE INSTALLED BY QUALIFIED PERSONNEL ONLY9.) MICRO INVERTER SHALL CONTAIN GROUND FAULT DETECTION AND INTERRUPTION DEVICES.10.) ALL WIRES ARE SIZED ACCORDING TO TEMPERATURE DERATING AND LOCATION.11.) IF THE EXISTING GROUNDING ELECTRODE SYSTEM CANNOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, CONTRACTOR SHALL INSTALL ASUPPLEMENTAL GROUNDING ELECTRODEAS PER CALIFORNIA RESIDENTIAL CODE CRC SECTIONS R14 AND R15PROVIDE SMOKE ALARMS ON THE FOLLOWING LOCATIONS:1.SMOKE ALARM IN ALL SLEEPING ROOMS.2.CO ALARMS IN ALL SLEEPING ROOMS WITHIN WHICH FUEL BURNING APPLIANCES ARE INSTALLED.3.SMOKE ALARMS AND CO ALARM IN AREA PRECEDING SLEEPING ROOMS (SUCH AS HALLWAY),AND4.SMOKE ALARM AND CO ALARM ON EACH STORY LEVEL OF THE DWELLING INCLUDING BASEMENTS AND HABITABLE ATTIC ROOMSSTRING #1=09 MODULESSTRING #2=08 MODULESAC CONDUCTOR AMPACITYFROM INVERTER TO MAIN SERVICE PANELINVERTER CURRENT=32AMAX CURRENT=1.25X32=40.0AAWG#8 DERATED AMPACITY55X0.87X1.0=47.85A, 47.85A>40.0A,THEREFORE AC WIRE SIZE IS VALIDCALCULATIONS FOR CURRENT CARRYING CONDUCTORS:DC CONDUCTOR AMPACITYFROM MODULE TO JUNCTION BOX TO INVERTERIMAX PER BRANCH =IMPX1.25=15X1.25=18.75AAWG#10 DERATED AMPACITY40X0.65X0.8=20.8A20.8A>18.75A,THEREFORE DC WIRE SIZE IS VALIDINVERTER SPECIFICATIONS MANUFACTURER / MODEL #SOLAREDGE SE7600H-US NOMINAL AC POWER7.60 KW NOMINAL OUTPUT VOLTAGE240 VAC NOMINAL OUTPUT CURRENT32 ASOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #LG NEONR PRIME LG425QAK-A6 VMP41.3V IMP10.31A VOC48.1V ISC10.84A TEMP. COEFF. VOC-0.26%/°K MODULE DIMENSION75.19"L x 41.02"W x 1.57"D (In Inch) PTC RATING391.7WDC VOLTAGE DROP% CALCULATIONVD=25'X2X1.24X15/1000=0.93 V%VD=0.93 V/480 X100=0.19%AC VOLTAGE DROP% CALCULATIONVD=2'X2X0.778X32/1000=0.69 V%VD=0.69 V/240 X100=0.51% VOLTAGE DROP% CALCULATIONVD=L'X2X RESISTANCE X IMAX/1000=X V%VD=X VOLT/SYST VOLTAGEX100=Y%NOTE:THE PV SYSTEM GROUNDING ELECTRODE WILL BE BONDED TO THE EXISTING BUILDING GROUNDED CONDUCTOR AND THEN CONNECTED TO THE GROUND.B07/24/2023
8'-0" MAX9" MAX
4.5"MODULE WATT: 425 W(17)LG NEONR PRIME LG425QAK-A6SYSTEM SIZE:7.23 KW DC (STC) :6.65 KW DC (PTC) :6.59 KW AC (CEC)(01)INVERTER: SOLAREDGESE7600H-US(17)POWER OPTIMIZERS:SOLAREDGE P505AZIMUTH:185°ROOF TILT:0°ARRAY TILT:0° ON FLAT ROOFMOUNTING HEIGHT:1-STORYSIGNATURE AND SEALXSTATE LICENSE#LICENSE CLASSC-46EXPIRE DATE02/28/2022RIPPEERESIDENCEJURISDICTIONLA QUINTACITY OFDRAWING INFORMATIONREV#DESCRIPTIONDATEPERMITTINGDRAWNBYREVISIONPROJECT NAME AND ADDRESSDATE:11/11/2021SHEET NAMESHEET NUMBER78761 DEACON DR EASTLOT#26LA QUINTA,CA,92253PHONE:()OCCUPANCY TYPE:V-BGROUP:RAPN:770-230-016BPSUNLOGIX ENERGY77585 ENFIELD LN SUITE APALM DESERT,CA,92211PHONE:760-844-6507CONTRACTOR:ZACHARY N GAMEZ1063414SOLAR PANELPORTRAITNO TILTATTACHMENTDETAILSPV52X4 TRUSS @24" O.C1ATTACHMENT TYPE: PROSOLAR FAST JACK (HOT ROLLED COMP ROOF)SCALE: NTSPV5IRON EIDGERAIL5/16"x3-1/2" SS LAG BOLT@ 4' O.C Max.OVER EXISTING SHEATHING AND ROOF TRUSSES ASSHOWN. MIN 2-1/2" PENETRATION2X4 TRUSS @24" O.C(E)HOT ROLLED COMPROOF(E)1/2" CDXPLYWOODPRO SOLARFAST JACK 4.5"STANDOFFBOTH LEGSCHEM CURB FLASHINGSL FOOT3/8 "x 1" SS LAG BOLTS07/24/2023
MSPACDINV JBMODULE WATT: 425 W(17)LG NEONR PRIME LG425QAK-A6SYSTEM SIZE:7.23 KW DC (STC) :6.65 KW DC (PTC) :6.59 KW AC (CEC)(01)INVERTER: SOLAREDGESE7600H-US(17)POWER OPTIMIZERS:SOLAREDGE P505AZIMUTH:185°ROOF TILT:0°ARRAY TILT:0° ON FLAT ROOFMOUNTING HEIGHT:1-STORYSIGNATURE AND SEALXSTATE LICENSE#LICENSE CLASSC-46EXPIRE DATE02/28/2022RIPPEERESIDENCEJURISDICTIONLA QUINTACITY OFDRAWING INFORMATIONREV#DESCRIPTIONDATEPERMITTINGDRAWNBYREVISIONPROJECT NAME AND ADDRESSDATE:11/11/2021SHEET NAMESHEET NUMBER78761 DEACON DR EASTLOT#26LA QUINTA,CA,92253PHONE:()OCCUPANCY TYPE:V-BGROUP:RAPN:770-230-016BPSUNLOGIX ENERGY77585 ENFIELD LN SUITE APALM DESERT,CA,92211PHONE:760-844-6507CONTRACTOR:ZACHARY N GAMEZ1063414! WARNING !ELECTRIC SHOCK HAZARDTHE TERMINALS ON LINE AND LOADSIDE MAY BE ENERGIZED IN THEOPEN POSITION(690.13(B) CEC AT ALL "J" BOXES, COMBINERBOX,ENCLOSURES/EMTENCLOSURES/DISCONNECTS! WARNING !POWER SOURCE OUTPUT CONNECTIONS,DONOT RELOCATE THIS OVER CURRENTDEVICENEC 705.12 (B)(2)(3)(b)PLACED ONMAIN PANEL/BREAKER LOCATIONPV SOLAR BREAKERDO NOT RELOCATE THISOVERCURRENT DEVICEPLACED ON SOLAR BREAKER! WARNING !DUAL POWER SOURCE SECOND SOURCEIS PHOTOVOLTAICCEC 705.12 D(3),NEC 690.59 ON MAINPANEL! WARNING !PHOTOVOLTAIC POWER SOURCEON ALL CONDUITS SPACED AT MAX 10 FTPLACARDSPV6APOWER TO THIS BUILDING IS ALSO SUPPLIED FROMTHE FOLLOWING SOURCE WITH DISCONNECT LOCATEDAS SHOWNCAUTIONPHOTOVOLTAICAC DISCONNECTRATED AC OUTPUT CURRENT 32 ANOMINAL OPERATING AC VOLTAGE 240 VCEC 690.54 PLACED ON ACDISCONNECT/AC COMBINER BOXSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR ELECTRICPV PANELSWITHIN 3 FT OF MAIN PANEL/ACDISCONNECT/STRING INVERTERDEACON DR EPLAQUES SHALL BE PLASTIC ENGRAVED IN A CONTRASTINGCOLOR TO THE PLAQUE. PLAQUE SHALL BE ATTACHED TO THESERVICE EQUIPMENT WITH POP-RIVETS OR ADHESIVE.WARNING LABELSWHITE LETTERS ON RED BACKGROUND AND NON-BOLD ARIAL OR SIMILAR FONT.MARKING SHALL BE REFLECTIVE, WEATHER RESISTANTMATERIAL SUITABLE FOR THE ENVIRONMENTCEC 690.56 C(3) PLACED WITHIN 3 FTOF RAPID SHUT DOWN SWITCHDC VOLTAGE IS ALWAYS PRESENTWHEN SOLAR MODULES AREEXPOSED TO SUNLIGHT! WARNING !PHOTOVOLTAIC POWER SOURCECEC 690.31 (G)3-4 ON ALL EMT CONDUIT,ENCLOSURE,COMBINERBOXES,DISCONNECTS!! WARNING !TURN OFF PHOTOVOLTAICDISCONNECT PRIOR TO WORKINGINSIDE PANELNEC 110.27 C, COMBINER BOX,ENCLOSURE/CONDUITENCLOSURE/DISCONNECTRAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMMAINPANELUTILITY DG ACDISCONNECTPHOTOVOLTAICSYSTEMMAXIMUM VOLTAGE 480VMAXIMUM CIRCUIT CURRENT 27AMAXIMUM RATED OUTPUT CURRENTDC-DC CONVERTER 15APLACED ON INVERTERDC DISCONNECT LABELPHOTOVOLTAICSOLAR ON ROOF! WARNING !DUAL POWER SUPPLYSOURCES:UTILITY GRID ANDPV SOLAR ELECTRIC SERVICESPLACED ON MAIN PANELINVERTER(IN GARAGE)! WARNING !TURN OFF UTILITY DG AC DISCONNECTPRIOR TO WORKING INSIDE PANELPLACED ON MAIN PANELUTILITY DG DISCONNECTSAFETY SWITCHPV SYSTEM! AC DISCONNECT !PLACED ON UTILITY DG ACDISCONNECT X207/24/2023
MSPACD
INV JB(N) 200 A DPBMODULE WATT: 425 W(17)LG NEONR PRIME LG425QAK-A6SYSTEM SIZE:7.23 KW DC (STC) :6.65 KW DC (PTC) :6.59 KW AC (CEC)(01)INVERTER: SOLAREDGESE7600H-US(17)POWER OPTIMIZERS:SOLAREDGE P505AZIMUTH:185°ROOF TILT:0°ARRAY TILT:0° ON FLAT ROOFMOUNTING HEIGHT:1-STORYSIGNATURE AND SEALXSTATE LICENSE#LICENSE CLASSC-46EXPIRE DATE02/28/2022RIPPEERESIDENCEJURISDICTIONLA QUINTACITY OFDRAWING INFORMATIONREV#DESCRIPTIONDATEPERMITTINGDRAWNBYREVISIONPROJECT NAME AND ADDRESSDATE:11/11/2021SHEET NAMESHEET NUMBER78761 DEACON DR EASTLOT#26LA QUINTA,CA,92253PHONE:()OCCUPANCY TYPE:V-BGROUP:RAPN:770-230-016BPSUNLOGIX ENERGY77585 ENFIELD LN SUITE APALM DESERT,CA,92211PHONE:760-844-6507CONTRACTOR:ZACHARY N GAMEZ1063414OPTIMIZER CHARTPV6BOPTIMIZERS/MICRO-INVERTERS CHARTSTRING LAYOUT
MODULE WATT: 425 W(17)LG NEONR PRIME LG425QAK-A6SYSTEM SIZE:7.23 KW DC (STC) :6.65 KW DC (PTC) :6.59 KW AC (CEC)(01)INVERTER: SOLAREDGESE7600H-US(17)POWER OPTIMIZERS:SOLAREDGE P505AZIMUTH:185°ROOF TILT:0°ARRAY TILT:0° ON FLAT ROOFMOUNTING HEIGHT:1-STORYSIGNATURE AND SEALXSTATE LICENSE#LICENSE CLASSC-46EXPIRE DATE02/28/2022RIPPEERESIDENCEJURISDICTIONLA QUINTACITY OFDRAWING INFORMATIONREV#DESCRIPTIONDATEPERMITTINGDRAWNBYREVISIONPROJECT NAME AND ADDRESSDATE:11/11/2021SHEET NAMESHEET NUMBER78761 DEACON DR EASTLOT#26LA QUINTA,CA,92253PHONE:()OCCUPANCY TYPE:V-BGROUP:RAPN:770-230-016BPSUNLOGIX ENERGY77585 ENFIELD LN SUITE APALM DESERT,CA,92211PHONE:760-844-6507CONTRACTOR:ZACHARY N GAMEZ1063414EQUIPMENTSPECIFICATIONSPV7
MODULE WATT: 425 W(17)LG NEONR PRIME LG425QAK-A6SYSTEM SIZE:7.23 KW DC (STC) :6.65 KW DC (PTC) :6.59 KW AC (CEC)(01)INVERTER: SOLAREDGESE7600H-US(17)POWER OPTIMIZERS:SOLAREDGE P505AZIMUTH:185°ROOF TILT:0°ARRAY TILT:0° ON FLAT ROOFMOUNTING HEIGHT:1-STORYSIGNATURE AND SEALXSTATE LICENSE#LICENSE CLASSC-46EXPIRE DATE02/28/2022RIPPEERESIDENCEJURISDICTIONLA QUINTACITY OFDRAWING INFORMATIONREV#DESCRIPTIONDATEPERMITTINGDRAWNBYREVISIONPROJECT NAME AND ADDRESSDATE:11/11/2021SHEET NAMESHEET NUMBER78761 DEACON DR EASTLOT#26LA QUINTA,CA,92253PHONE:()OCCUPANCY TYPE:V-BGROUP:RAPN:770-230-016BPSUNLOGIX ENERGY77585 ENFIELD LN SUITE APALM DESERT,CA,92211PHONE:760-844-6507CONTRACTOR:ZACHARY N GAMEZ1063414EQUIPMENTSPECIFICATIONSPV8A
MODULE WATT: 425 W(17)LG NEONR PRIME LG425QAK-A6SYSTEM SIZE:7.23 KW DC (STC) :6.65 KW DC (PTC) :6.59 KW AC (CEC)(01)INVERTER: SOLAREDGESE7600H-US(17)POWER OPTIMIZERS:SOLAREDGE P505AZIMUTH:185°ROOF TILT:0°ARRAY TILT:0° ON FLAT ROOFMOUNTING HEIGHT:1-STORYSIGNATURE AND SEALXSTATE LICENSE#LICENSE CLASSC-46EXPIRE DATE02/28/2022RIPPEERESIDENCEJURISDICTIONLA QUINTACITY OFDRAWING INFORMATIONREV#DESCRIPTIONDATEPERMITTINGDRAWNBYREVISIONPROJECT NAME AND ADDRESSDATE:11/11/2021SHEET NAMESHEET NUMBER78761 DEACON DR EASTLOT#26LA QUINTA,CA,92253PHONE:()OCCUPANCY TYPE:V-BGROUP:RAPN:770-230-016BPSUNLOGIX ENERGY77585 ENFIELD LN SUITE APALM DESERT,CA,92211PHONE:760-844-6507CONTRACTOR:ZACHARY N GAMEZ1063414EQUIPMENTSPECIFICATIONSPV8B
MODULE WATT: 425 W(17)LG NEONR PRIME LG425QAK-A6SYSTEM SIZE:7.23 KW DC (STC) :6.65 KW DC (PTC) :6.59 KW AC (CEC)(01)INVERTER: SOLAREDGESE7600H-US(17)POWER OPTIMIZERS:SOLAREDGE P505AZIMUTH:185°ROOF TILT:0°ARRAY TILT:0° ON FLAT ROOFMOUNTING HEIGHT:1-STORYSIGNATURE AND SEALXSTATE LICENSE#LICENSE CLASSC-46EXPIRE DATE02/28/2022RIPPEERESIDENCEJURISDICTIONLA QUINTACITY OFDRAWING INFORMATIONREV#DESCRIPTIONDATEPERMITTINGDRAWNBYREVISIONPROJECT NAME AND ADDRESSDATE:11/11/2021SHEET NAMESHEET NUMBER78761 DEACON DR EASTLOT#26LA QUINTA,CA,92253PHONE:()OCCUPANCY TYPE:V-BGROUP:RAPN:770-230-016BPSUNLOGIX ENERGY77585 ENFIELD LN SUITE APALM DESERT,CA,92211PHONE:760-844-6507CONTRACTOR:ZACHARY N GAMEZ1063414EQUIPMENTSPECIFICATIONSPV9
MODULE WATT: 425 W(17)LG NEONR PRIME LG425QAK-A6SYSTEM SIZE:7.23 KW DC (STC) :6.65 KW DC (PTC) :6.59 KW AC (CEC)(01)INVERTER: SOLAREDGESE7600H-US(17)POWER OPTIMIZERS:SOLAREDGE P505AZIMUTH:185°ROOF TILT:0°ARRAY TILT:0° ON FLAT ROOFMOUNTING HEIGHT:1-STORYSIGNATURE AND SEALXSTATE LICENSE#LICENSE CLASSC-46EXPIRE DATE02/28/2022RIPPEERESIDENCEJURISDICTIONLA QUINTACITY OFDRAWING INFORMATIONREV#DESCRIPTIONDATEPERMITTINGDRAWNBYREVISIONPROJECT NAME AND ADDRESSDATE:11/11/2021SHEET NAMESHEET NUMBER78761 DEACON DR EASTLOT#26LA QUINTA,CA,92253PHONE:()OCCUPANCY TYPE:V-BGROUP:RAPN:770-230-016BPSUNLOGIX ENERGY77585 ENFIELD LN SUITE APALM DESERT,CA,92211PHONE:760-844-6507CONTRACTOR:ZACHARY N GAMEZ1063414EQUIPMENTSPECIFICATIONSPV10
MODULE WATT: 425 W(17)LG NEONR PRIME LG425QAK-A6SYSTEM SIZE:7.23 KW DC (STC) :6.65 KW DC (PTC) :6.59 KW AC (CEC)(01)INVERTER: SOLAREDGESE7600H-US(17)POWER OPTIMIZERS:SOLAREDGE P505AZIMUTH:185°ROOF TILT:0°ARRAY TILT:0° ON FLAT ROOFMOUNTING HEIGHT:1-STORYSIGNATURE AND SEALXSTATE LICENSE#LICENSE CLASSC-46EXPIRE DATE02/28/2022RIPPEERESIDENCEJURISDICTIONLA QUINTACITY OFDRAWING INFORMATIONREV#DESCRIPTIONDATEPERMITTINGDRAWNBYREVISIONPROJECT NAME AND ADDRESSDATE:11/11/2021SHEET NAMESHEET NUMBER78761 DEACON DR EASTLOT#26LA QUINTA,CA,92253PHONE:()OCCUPANCY TYPE:V-BGROUP:RAPN:770-230-016BPSUNLOGIX ENERGY77585 ENFIELD LN SUITE APALM DESERT,CA,92211PHONE:760-844-6507CONTRACTOR:ZACHARY N GAMEZ1063414EQUIPMENTSPECIFICATIONSPV10
MODULE WATT: 425 W(17)LG NEONR PRIME LG425QAK-A6SYSTEM SIZE:7.23 KW DC (STC) :6.65 KW DC (PTC) :6.59 KW AC (CEC)(01)INVERTER: SOLAREDGESE7600H-US(17)POWER OPTIMIZERS:SOLAREDGE P505AZIMUTH:185°ROOF TILT:0°ARRAY TILT:0° ON FLAT ROOFMOUNTING HEIGHT:1-STORYSIGNATURE AND SEALXSTATE LICENSE#LICENSE CLASSC-46EXPIRE DATE02/28/2022RIPPEERESIDENCEJURISDICTIONLA QUINTACITY OFDRAWING INFORMATIONREV#DESCRIPTIONDATEPERMITTINGDRAWNBYREVISIONPROJECT NAME AND ADDRESSDATE:11/11/2021SHEET NAMESHEET NUMBER78761 DEACON DR EASTLOT#26LA QUINTA,CA,92253PHONE:()OCCUPANCY TYPE:V-BGROUP:RAPN:770-230-016BPSUNLOGIX ENERGY77585 ENFIELD LN SUITE APALM DESERT,CA,92211PHONE:760-844-6507CONTRACTOR:ZACHARY N GAMEZ1063414EQUIPMENTSPECIFICATIONSPV12