BRES2021-0834 - Title 24CERTIFICATE OF COMPLIANCE
Project Name: Rippee Residence
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-07-18T08:10:19-07:00 (Page 1 of 15)
Input File Name: Traditions lot 26 Rippee-LQ-DeFord-21.ribdl9x
GENERAL INFORMATION
01
Project Name
Rippee Residence
02
Run Title
Title 24 Analysis
03
Project Location
78-761 Deacon Drive East
04
City
La Quinta 05 Standards Version
92253 REVISION 2 Software Version
15 BRES2021-0834 Front Orientation (deg/ Cardinal)
Single family CITY OF LA QUINTA Number of Dwelling Units
NewConstruction BUILDING DIVISION Number of Bedrooms
REVIEWED FOR
0 CODE Number of Stories
COMPLIANCE
n/a D,,07/20/2023 BY -F- Fenestration Average U-factor
4241 SOLAR PV SYSTEM Glazing Percentage (%)
n/a UPDATES + BUILDING ADU Conditioned Floor Area
Yes ENVELOPE
2019
06
Zip code
EnergyPro 8.3
08
Climate Zone
90
10
Building Type
1
12
Project Scope
3
14
Addition Cond. Floor Area (ft)
1
16
Existing Cond. Floor Area (ft)
0.36
18
Total Cond. Floor Area (ft)
19.54%
20
ADU Bedroom Count
n/a
22
Is Natural Gas Available?
INSIJI ATI0N CHANGF
------- ------ ---- ------
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
Registration Number: 423-P010124990A-000-000-0000000-0000 Registration Date/Time: 07/18/2023 08:15 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-07-18 08:11:57
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Rippee Residence
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-07-18T08:10:19-07:00 (Page 2 of 15)
Input File Name: Traditions lot 26 Rippee-LQ-DeFord-21.ribdl9x
ENERGY DESIGN RATING
Energy Design Ratings
Compliance Margins
Efficiency' (EDR)
TotalZ (EDR)
Efficiency' (EDR)
TotalZ (EDR)
Standard Design
44.5
22.7
Proposed Design
40.6
21
3.9
1.7
RESULT: 3' COMPLIES
1: Efficiency EDR includes improvements to the building envelope and more efficient equipment
2: Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries
3: Building complies when efficiency and total compliance margins are greater than or equal to zero
• Standard Design PV Capacity: 7.68 kWdc
ENERGY USE SUMMARY
Energy Use (kTDV/ftz-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
3.53
7.79
-4.26
-120.7
Space Cooling
92.47
75.98
16.49
17.8
IAQ Ventilation
2.87
2.87
0
0
Water Heating
4.74
5.31
-0.57
-12
Self Utilization/Flexibility Credit
n/a
0
0
n/a
Compliance Energy Total
103.61
91.95
11.66
11.3
REQUIRED PV SYSTEMS - SIMPLIFIED
01
02
03
04
05
06
07
08
09
10
11
12
DC System Size
Exception
Module Type
Array Type
Power Electronics
CFI
Azimuth
Tilt
Array Angle
Tilt: (x in
Inverter Eff.
Annual
Solar Access
(kWdc)
(deg)
Input
(deg)
12)
N
N
7.23
NA
Standard
Fixed
none
false
180
Degre
0
0
96
100
es
Registration Number: 423-P010124990A-000-000-0000000-0000 Registration Date/Time: 07/18/2023 08:15 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-07-18 08:11:57
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Rippee Residence
Calculation Description: Title 24 Analysis
REQUIRED SPECIAL FEATURES
CF1R-PRF-01E
Calculation Date/Time: 2023-07-18T08:10:19-07:00 (Page 3 of 15)
Input File Name: Traditions lot 26 Rippee-LQ-DeFord-21.ribd19x
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cool roof
• Insulation below roof deck
• Window overhangs and/or fins
• Non-standard duct location (any location other than attic)
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building -level Verifications:
• Quality insulation installation (QII)
• Indoor air quality ventilation
• Kitchen range hood
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Fan Efficacy Watts/CFM
Heating System Verifications:
• Verified heat pump rated heating capacity
HVAC Distribution System Verifications:
• Duct leakage testing
• Ducts located entirely in conditioned space confirmed by duct leakage testing
Domestic Hot Water System Verifications:
• Pipe Insulation, All Lines
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ftZ)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Rippee Residence
4241
1
3
4
0
1
Registration Number: 423-P010124990A-000-000-0000000-0000 Registration Date/Time: 07/18/2023 08:15 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-07-18 08:11:57
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Rippee Residence
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-07-18T08:10:19-07:00 (Page 4 of 15)
Input File Name: Traditions lot 26 Rippee-LQ-DeFord-21.ribdl9x
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area (ft)
Avg. Ceiling Height
Water Heating System 1
Water Heating System 2
primary bedroom
Conditioned
HVAC mstr 4ton1
1054
10.5
DHW Sys 1
N/A
bedroom 4
Conditioned
HVAC bed4 2ton2
467
10.5
DHW Sys 1
N/A
bedroom 2
Conditioned
HVAC bed 4 TON3
1062
10.5
DHW Sys 1
N/A
great room
Conditioned
HVAC grt 5 ton4
1658
10.5
DHW Sys 1
N/A
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ftz)
Window and Door
Area (ft2)
Tilt (deg)
N Wall
primary bedroom
R-21 Wall
0
Right
600
73.5
90
E Wall
primary bedroom
R-21 Wall
90
Front
72
0
90
S Wall
primary bedroom
R-21 Wall
180
Left
240
0
90
W Wall
primary bedroom
R-21 Wall
270
Back
325
4
90
N Wall 2
bedroom 4
R-21 Wall
0
Right
100
6
90
NE Wall
bedroom 4
R-21 Wall
45
n/a
180
42
90
E Wall 2
bedroom 4
R-21 Wall
90
Front
72
0
90
SE Wall
bedroom 4
R-21 Wall
135
n/a
180
0
90
S Wall 2
bedroom 4
R-21 Wall
180
Left
100
33.5
90
SW Wall
bedroom 4
R-21 Wall
225
n/a
60
18
90
W Wall 2
bedroom 4
R-21 Wall
270
Back
60
0
90
NW Wall
bedroom 4
R-21 Wall
315
n/a
60
0
90
N Wall 3
bedroom 2
R-21 Wall
0
Right
516
90.9
90
E Wall 3
bedroom 2
R-21 Wall
90
Front
516
12.5
90
S Wall 3
bedroom 2
R-21 Wall
180
Left
516
61
90
W Wall 3
bedroom 2
R-21 Wall
270
Back
144
36
90
Registration Number: 423-P010124990A-000-000-0000000-0000 Registration Date/Time: 07/18/2023 08:15 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-07-18 08:11:57
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Rippee Residence
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-07-18T08:10:19-07:00 (Page 5 of 15)
Input File Name: Traditions lot 26 Rippee-LQ-DeFord-21.ribd19x
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window and Door
Area (ft2)
Tilt (deg)
N Wall 4
great room
R-21 Wall
0
Right
260
4
90
E Wall 4
great room
R-21 Wall
90
Front
208
95
90
S Wall 4
great room
R-21 Wall
180
Left
624
42.5
90
W Wall 4
great room
R-21 Wall
270
Back
630
310
90
Interior Surface
primary bedroom
R-0 Interior Wall
n/a
n/a
412
0
n/a
Interior Surface 2
bedroom 4
R-0 Interior Wall
n/a
n/a
412
0
n/a
Interior Surface 3
bedroom 2
R-0 Interior Wall
n/a
n/a
412
0
n/a
Interior Surface 4
great room
R-0 Interior Wall
n/a
n/a
412
0
n/a
Roofmstr
primary bedroom
foam
n/a
n/a
1054
n/a
n/a
Roofbed4
bedroom 4
foam
n/a
n/a
467
n/a
n/a
Roofbed23
bedroom 2
foam
n/a
n/a
1062
n/a
n/a
Roofgrt
great room
foam
n/a
n/a
1658
n/a
n/a
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise (x in 12)
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic primary bedroom
Attic Roofprimary
bedroom
Unventilated
3
0.7
0.86
No
Yes
Attic bedroom 4
Attic Roofbedroom 4
Unventilated
3
0.7
0.86
No
Yes
Attic bedroom 2
Attic Roofbedroom 2
Unventilated
3
0.7
0.86
No
Yes
Attic great room
Attic Roofgreat room
Unventilated
3
0.7
0.86
No
Yes
Registration Number: 423-P010124990A-000-000-0000000-0000 Registration Date/Time: 07/18/2023 08:15 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-07-18 08:11:57
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Rippee Residence
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-07-18T08:10:19-07:00 (Page 6 of 15)
Input File Name: Traditions lot 26 Rippee-LQ-DeFord-21.ribdl9x
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Name
Type
Surface
Orientation
Azimuth
Width
(ft)
Height
(ft)
Mult.
Area
(ft2)
U-factor
U-factor
Source
SHGC
SHGC
Sourc
e
Exterior
Shading
115
Window
N Wall
Right
0
1
4
0.36
NFRC
0.22
NFRC
Bug Screen
114
Window
N Wall
Right
0
1
4
0.36
NFRC
0.22
NFRC
Bug Screen
113
Window
N Wall
Right
0
1
4
0.36
NFRC
0.22
NFRC
Bug Screen
112
Window
N Wall
Right
0
1
4
0.36
NFRC
0.22
NFRC
Bug Screen
111
Window
N Wall
Right
0
1
4
0.36
NFRC
0.22
NFRC
Bug Screen
110
Window
N Wall
Right
0
1
6
0.36
NFRC
0.22
NFRC
Bug Screen
109
Window
N Wall
Right
0
1
17.5
0.36
NFRC
0.22
NFRC
Bug Screen
108
Window
N Wall
Right
0
1
17.5
0.36
NFRC
0.22
NFRC
Bug Screen
107
Window
N Wall
Right
0
1
12.5
0.36
NFRC
0.22
NFRC
Bug Screen
1132
Window
W Wall
Back
270
1
4
0.36
NFRC
0.22
NFRC
Bug Screen
106
Window
N Wall 2
Right
0
1
6
0.36
NFRC
0.22
NFRC
Bug Screen
105
Window
NE Wall
45
1
42
0.36
NFRC
0.22
NFRC
Bug Screen
116
Window
S Wall 2
Left
180
1
21
0.36
NFRC
0.22
NFRC
Bug Screen
103
Window
S Wall 2
Left
180
1
12.5
0.36
NFRC
0.22
NFRC
Bug Screen
104
Window
SW Wall
225
1
18
0.36
NFRC
0.22
NFRC
Bug Screen
136
Window
N Wall 3
Right
0
1
28
0.36
NFRC
0.22
NFRC
Bug Screen
135
Window
N Wall
Right
0
1
28
0.36
NFRC
0.22
NFRC
Bug Screen
134
Window
N Wall
Right
0
1
28
0.36
NFRC
0.22
NFRC
Bug Screen
132
Window
N Wall 3
Right
0
1
2.3
0.36
NFRC
0.22
NFRC
Bug Screen
131
Window
N Wall 3
Right
0
1
2.3
0.36
NFRC
0.22
NFRC
Bug Screen
130
Window
N Wall 3
Right
0
1
2.3
0.36
NFRC
0.22
NFRC
Bug Screen
1032
Window
E Wall 3
Front
90
1
12.5
0.36
NFRC
0.22
NFRC
Bug Screen
124
Window
S Wall 3
Left
180
1
25
0.36
NFRC
0.22
NFRC
Bug Screen
123
Window
S Wall 3
Left
180
1
18
0.36
NFRC
0.22
NFRC
Bug Screen
Registration Number: 423-P010124990A-000-000-0000000-0000 Registration Date/Time: 07/18/2023 08:15 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-07-18 08:11:57
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Rippee Residence
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-07-18T08:10:19-07:00 (Page 7 of 15)
Input File Name: Traditions lot 26 Rippee-LQ-DeFord-21.ribdl9x
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Name
Type
Surface
Orientation
Azimuth
Width
(ft)
Height
(ft)
Mult.
Area
(ftz)
U-factor
U-factor
Source
SHGC
SHGC
Sourc
e
Exterior
Shading
122
Window
S Wall 3
Left
180
1
18
0.36
NFRC
0.22
NFRC
Bug Screen
133
Window
W Wall 3
Back
270
1
36
0.36
NFRC
0.22
NFRC
Bug Screen
1112
Window
N Wall 4
Right
0
1
4
0.36
NFRC
0.22
NFRC
Bug Screen
102
Window
E Wall 4
Front
90
1
22.5
0.36
NFRC
0.22
NFRC
Bug Screen
102d
Window
E Wall 4
Front
90
5
10
1
50
0.36
NFRC
0.22
NFRC
Bug Screen
101
Window
E Wall 4
Front
90
1
22.5
0.36
NFRC
0.22
NFRC
Bug Screen
121
Window
S Wall 4
Left
180
1
8
0.36
NFRC
0.22
NFRC
Bug Screen
120
Window
S Wall 4
Left
180
1
22.5
0.36
NFRC
0.22
NFRC
Bug Screen
119
Window
S Wall 4
Left
180
1
6
0.36
NFRC
0.22
NFRC
Bug Screen
118
Window
S Wall 4
Left
180
1
6
0.36
NFRC
0.22
NFRC
Bug Screen
1102
Window
W Wall 4
Back
270
12
10
1
120
0.36
NFRC
0.22
NFRC
Bug Screen
1122
Window
W Wall 4
Back
270
19
10
1
190
0.36
NFRCJ
0.22
1 NFRC
Bug Screen
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Window
Overhang
Left Fin
Right Fin
Depth
Dist Up
Left Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
102d
10
0.1
10
10
0
0
0
0
0
0
0
0
0
1102
12
0.1
12
12
0
0
0
0
0
0
0
0
0
1122
12
0.1
12
12
0
0
0
0
0
0
0
0
0
Registration Number: 423-P010124990A-000-000-0000000-0000 Registration Date/Time: 07/18/2023 08:15 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-07-18 08:11:57
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Rippee Residence
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-07-18T08:10:19-07:00 (Page 8 of 15)
Input File Name: Traditions lot 26 Rippee-LQ-DeFord-21.ribd19x
SLAB FLOORS
01
02
03
04
05
06
07
08
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value
and Depth
Edge Insul. R-value
and Depth
Carpeted Fraction
Heated
Slab -on -Grade
primary bedroom
1054
134
none
0
80%
No
Slab -on -Grade 2
bedroom 4
467
94
none
0
80%
No
Slab -on -Grade 3
bedroom 2
1062
125
none
0
80%
No
Slab -on -Grade 4
great room
1658
157
none
0
80%
No
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
Interior / Exterior
Construction Name
Surface Type
Construction Type
Framing
Total Cavity
R-value
Continuous
U-factor
Assembly Layers
R-value
Inside Finish: Gypsum Board
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. 0. C.
R-21
None / None
0.069
Cavity / Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
Inside Finish: Gypsum Board
R-0 Interior Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. 0. C.
R-0
None / None
0.277
Cavity / Frame: no insul. / 2x4
Other Side Finish: Gypsum Board
Roofing: Light Roof (Asphalt Shingle)
Attic Roofprimary
Wood Framed
Roof Deck: Wood
bedroom
Attic Roofs
Ceiling
2x4 @ 24 in. 0. C.
R-30
None / None
0.043
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-17.0 insul.
Roofing: Light Roof (Asphalt Shingle)
Wood Framed
Roof Deck: Wood
Attic Roofbedroom 4
Attic Roofs
Ceiling
2x4 @ 24 in. 0. C.
R-30
None / None
0.043
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-17.0 insul.
Registration Number: 423-P010124990A-000-000-0000000-0000 Registration Date/Time: 07/18/2023 08:15 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-07-18 08:11:57
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Rippee Residence
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-07-18T08:10:19-07:00 (Page 9 of 15)
Input File Name: Traditions lot 26 Rippee-LQ-DeFord-21.ribdl9x
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
Interior / Exterior
Construction Name
Surface Type
Construction Type
Framing
Total Cavity
R-value
Continuous
U-factor
Assembly Layers
R-value
Roofing: Light Roof (Asphalt Shingle)
Wood Framed
Roof Deck: Wood
Attic Roofbedroom 2
Attic Roofs
2x4 @ 24 in. 0. C.
R-30
None / None
0.043
Siding/sheathing/decking
Ceiling
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-17.0 insul.
Roofing: Light Roof (Asphalt Shingle)
Wood Framed
Roof Deck: Wood
Attic Roofgreat room
Attic Roofs
Ceiling
2x4 @ 24 in. 0. C.
R-30
None / None
0.043
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-17.0 insul.
foam
Ceilings (below
Wood Framed
2x4 @ 16 in. O. C.
R 0
None None
0.472
Cavity / Frame: no insul. / 2x4
attic)
Ceiling
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
High R-value Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
Name
System Type
Distribution Type
Water Heater Name (tt)
Solar Heating System
Compact Distribution
HERS Verification
DHW Sys 1
Domestic Hot Water
(DHW)
HERS Verified Pipe
Insulation credit
DHW Heater 1 (2)
n/a
None
DHW Sys 1 hers dhw
Registration Number: 423-P010124990A-000-000-0000000-0000 Registration Date/Time: 07/18/2023 08:15 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-07-18 08:11:57
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Rippee Residence
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-07-18T08:10:19-07:00 (Page 10 of 15)
Input File Name: Traditions lot 26 Rippee-LQ-DeFord-21.ribd19x
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Heating
Tank
Energy
Tank
Standby Loss
Name
Element
Tank Type
# of
Vol.
Factor or
Input Rating
Insulation
or Recovery
1st Hr. Rating
NEEA Heat Pump
Tank Location or
Type
Units
(gal)
Efficiency
or Pilot
R-value
Eff
or Flow Rate
Brand or Model
Ambient Condition
(Int/Ext)
DHW Heater 1
Gas
Consumer
2
0
0.96-LIEF
<= 200
0
n/a
n/a
n/a
n/a
Instantaneous
kBtu/hr
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Type Compact Distribution
Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1- 1/2
Required
Not Required
Not Required
None
Not Required
Not Required
Not Required
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
10
11
Required
Verified
Heating
Cooling
Name
System Type
Heating Unit
Cooling Unit
Fan Name
Distribution
Thermostat
Status
Existing
Equipment
Equipment
Name
Name
Name
Type
Condition
Count
Count
Heat Pump
Heat Pump
Air
HVAC mstr 4ton1
Heat pump heating cooling
HVAC Fan 1
Distribution
Setback
New
NA
1
1
System 1
System 1
System 1
Air
HVAC bed4 2ton2
Heat pump heating cooling
Heat Pump
Heat Pump
HVAC Fan 2
Distribution
Setback
New
NA
1
1
System 2
System 2
System 2
Air
HVAC bed2 4 TON3
Heat pump heating cooling
Heat Pump
Heat Pump
HVAC Fan 3
Distribution
Setback
New
NA
1
1
System 3
System 3
System 3
Registration Number: 423-P010124990A-000-000-0000000-0000 Registration Date/Time: 07/18/2023 08:15 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-07-18 08:11:57
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Rippee Residence
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-07-18T08:10:19-07:00 (Page 11 of 15)
Input File Name: Traditions lot 26 Rippee-LQ-DeFord-21.ribd19x
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
10
11
Heating Unit
Cooling Unit
Distribution
Required
Verified
Heating
Cooling
Name
System Type
Fan Name
Thermostat
Status
Existing
Equipment
Equipment
Name
Name
Name
Type
Condition
Count
Count
Air
HVAC grt 5 ton4
Heat pump heating cooling
Heat Pump
Heat Pump
HVAC Fan 4
Distribution
Setback
New
NA
1
1
System 4
System 4
System 4
01
02
03
04
05
06
07
08
09
10
11
HVAC - HEAT PUMPS
Heating
Cooling
Name
System Type
y Yp
Number of Units
Zonally
Controlled
Compressor
Type
HERS Verification
HSPF/HSPF2
EER/EER2/C
/COP
Cap 47
Cap 17
SEER/SEER2
EER
Heat Pump System 1
Central split HP
1
8
47500
35625
16
13
Not Zonal
Single
Heat Pump System
Speed
1-hers-htpump
Heat Pump System 2
Central split HP
1
8
22500
13500
16
13
Not Zonal
Single
Heat Pump System
Speed
2-hers-htpump
Heat Pump System 3
Central split HP
1
8
47500
35625
16
13
Not Zonal
Single
Heat Pump System
Speed
3-hers-htpump
Heat Pump System 4
Central split HP
1
8
55000
33000
16
13
Not Zonal
Single
Heat Pump System
Speed
4-hers-htpump
HVAC HEAT PUMPS - HERS VERIFICATION
01
02
03
04
05
06
07
08
09
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Verified HSPF
Verified Heating
Verified Heating
Charge
Cap 47
Cap 17
Heat Pump System
Required
350
Required
Required
No
No
Yes
Yes
1-hers-htpump
Heat Pump System
Required
350
Required
Required
No
No
Yes
Yes
2-hers-htpump
Registration Number: 423-P010124990A-000-000-0000000-0000 Registration Date/Time: 07/18/2023 08:15 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-07-18 08:11:57
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Rippee Residence
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-07-18T08:10:19-07:00 (Page 12 of 15)
Input File Name: Traditions lot 26 Rippee-LQ-DeFord-21.ribd19x
HVAC HEAT PUMPS - HERS VERIFICATION
01
02
03
04
05
06
07
08
09
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Verified HSPF
Verified Heating
Verified Heating
Charge
Cap 47
Cap 17
Heat Pump System
Required
350
Required
Required
No
No
Yes
Yes
3-hers-htpump
Heat Pump System
Required
350
Required
Required
No
No
Yes
Yes
4-hers-htpump
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
11
12
Duct Ins. R-value
Duct Location
Surface Area
Name
Type
Design Type
Supply
Return
Supply
Return
Supply
Return
puts
Duct Leakage
HERS
Verification
Air
Air Distribution
Conditioned
Conditio
Conditio
NO
Distribution
System 1
space -entirely
Non -Verified
R 8
R-8
ned Zone
ned Zone
n/a
n/a
Bypass
System
Duct
1-hers-dirt
Air
Air Distribution
Conditioned
Conditio
Conditio
NO
Distribution
System 2
space -entirely
Non -Verified
R 8
R-8
ned Zone
ned Zone
n/a
n/a
Bypass
System
Duct
2-hers-dirt
NO
Air
Air Distribution
Conditioned
Non -Verified
R 8
R-8
Conditio
Conditio
n/a
n/a
Bypass
Distribution
System 3
space -entirely
ned Zone
ned Zone
System
Duct
3-hers-dist
NO
Air
Air Distribution
Conditioned
Non -Verified
R 8
R 8
Conditio
Conditio
n/a
n/a
Bypass
Distribution
System 4
space -entirely
ned Zone
ned Zone
System
Duct
4-hers-dirt
Registration Number: 423-P010124990A-000-000-0000000-0000 Registration Date/Time: 07/18/2023 08:15 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-07-18 08:11:57
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Rippee Residence
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-07-18T08:10:19-07:00 (Page 13 of 15)
Input File Name: Traditions lot 26 Rippee-LQ-DeFord-21.ribd19x
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
09
Low Leakage
Name
Duct Leakage
Duct Leakage
Verified Duct
Verified Duct
Buried Ducts
Deeply Buried
Low -leakage Air
Ducts Entirely in
Verification
Target (%)
Location
Design
g
Ducts
Handler
Conditioned
Space
Air Distribution
Yes
5.0
Required
Not Required
Not Required
Credit not taken
Required
No
System 1-hers-dist
Air Distribution
Yes
5.0
Required
Not Required
Not Required
Credit not taken
Required
No
System 2-hers-dist
Air Distribution
Yes
5.0
Required
Not Required
Not Required
Credit not taken
Required
No
System 3-hers-dist
Air Distribution
Yes
5.0
Required
Not Required
Not Required
Credit not taken
Required
No
System 4-hers-dist
HVAC - FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
Name
HVAC Fan 1
HVAC Fan
0.35
HVAC Fan 1-hers-fan
HVAC Fan 2
HVAC Fan
0.35
HVAC Fan 2-hers-fan
HVAC Fan 3
HVAC Fan
0.35
HVAC Fan 3-hers-fan
HVAC Fan 4
HVAC Fan
0.35
HVAC Fan 4-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.35
HVAC Fan 2-hers-fan
Required
0.35
Registration Number: 423-P010124990A-000-000-0000000-0000 Registration Date/Time: 07/18/2023 08:15 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-07-18 08:11:57
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Rippee Residence
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-07-18T08:10:19-07:00 (Page 14 of 15)
Input File Name: Traditions lot 26 Rippee-LQ-DeFord-21.ribd19x
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficacy (Watts/CFM)
HVAC Fan 3-hers-fan
Required
0.35
HVAC Fan 4-hers-fan
Required
0.35
IAQ (INDOOR AIR QUALITY) FANS
01
02
03
04
05
06
07
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness - SRE
IAQ RecoveryHERS
Effectiveness - ASRE
Verification
SFam IAQVentRpt
148
0.35
Exhaust
n/a
n/a
Yes
Registration Number: 423-P010124990A-000-000-0000000-0000 Registration Date/Time: 07/18/2023 08:15 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-07-18 08:11:57
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Rippee Residence
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-07-18T08:10:19-07:00 (Page 15 of 15)
Input File Name: Traditions lot 26 Rippee-LQ-DeFord-21.ribdl9x
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Jonathan Scott
J SG&M
Company:
Signature Date:
Scott Design and Title 24, Inc.
07/18/2023
Address:
CEA/ HERS Certification Identification (If applicable):
74-818 Velie Way STE 8
City/State/Zip:
Phone:
Palm desert, CA 92260
7602004780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Jonathan Scott
janathvvyv Scout
Company:
Date Signed:
Scott Design and Title 24, Inc.
07/18/2023
Address:
License:
74-818 Velie Way STE 8
City/State/Zip:
Phone:
Palm desert, CA 92260
7602004780
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is prov/ded in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 423-P010124990A-000-000-0000000-0000 Registration Date/Time: 07/18/2023 08:15 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-07-18 08:11:57
Schema Version: rev 20200901
CERTIFICATE OF INSTALLATION CF2R-ENV-01-E
Fenestration Installation (Page 1 of 7)
Project Name: Traditions lot 26 Rippee new23
Enforcement Agency: La Quinta, City of
Permit Number: 2021
Dwelling Address: 78-761 Deacon Drive East
City: La Quinta
Zip Code: 92253
If more than one person has responsibility for installation of the items on this certificate, each person shall prepare and sign a certificate applicable to the portion of construction for which they
are responsible. Alternatively, the person with chief responsibility for construction shall prepare and sign this certificate for the entire construction. The signer agrees that all applicable Mandatory
Measures were met. Temporary labels are not to be removed before verification by the building inspector.
Registration Number: 423-P010124990A-000-001-E01031A-0000 Registration Date/Time: 2023-07-20 07:24:36 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2023-07-20 07:24:36
Schema Version: rev 20190501
CERTIFICATE OF INSTALLATION CF2R-ENV-01-E
Fenestration Installation (Page 2 of 7)
A. Fenestration/ Glazing
Includes all Windows, Skylights, Greenhouse or Bay Windows and Glazed Doors.Note: If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 glass in door, it is assumed to
meet the minimum required U-factor (0.30) and SHGC (0.23).
If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 tubular skylight, it is assumed to meet the minimum required U-factor (0.55) and SHGC (0.30).
Doors with greater than or equal to 25 percent glazing area are considered glazed doors and are treated as fenestration products.
01
02
03
04
05
06
07
08
09
10
11
12
Manufacturer/
Fenestration
Fenestration
ExteriorComments/Sp
Tag ID
Brand
Area
Orientation
Chromogenic
U-factor
Source
SHGC
Source
Type
Shading
ecial Features
(ft)
Devices
Standard bug
115
owens
4.0000
0
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
114
owens
4.0000
0
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
113
owens
4.0000
0
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
112
owens
4.0000
0
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
111
owens
4.0000
0
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
110
owens
6.0000
0
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
109
owens
17.5000
0
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
108
owens
17.5000
0
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
107
owens
12.5000
0
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
1132
owens
4.0000
270
No
0.36
NFRC
0.22
NFRC
Window
screens
Registration Number: 423-P010124990A-000-001-E01031A-0000 Registration Date/Time: 2023-07-20 07:24:36 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2023-07-20 07:24:36
Schema Version: rev 20190501
CERTIFICATE OF INSTALLATION CF2R-ENV-01-E
Fenestration Installation (Page 3 of 7)
A. Fenestration/ Glazing
Includes all Windows, Skylights, Greenhouse or Bay Windows and Glazed Doors.Note: If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 glass in door, it is assumed to
meet the minimum required U-factor (0.30) and SHGC (0.23).
If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 tubular skylight, it is assumed to meet the minimum required U-factor (0.55) and SHGC (0.30).
Doors with greater than or equal to 25 percent glazing area are considered glazed doors and are treated as fenestration products.
01
02
03
04
05
06
07
08
09
10
11
12
Manufacturer/
Fenestration
Fenestration
ExteriorComments/Sp
Tag ID
Brand
Area (ft)
Orientation
Chromogenic
U-factor
Source
SHGC
Source
Type
Shading
ecial Features
Devices
Standard bug
106
owens
6.0000
0
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
105
owens
42.0000
45
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
116
owens
21.0000
180
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
103
owens
12.5000
180
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
104
owens
18.0000
225
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
136
owens
28.0000
0
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
135
owens
28.0000
0
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
134
owens
28.0000
0
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
132
owens
2.3000
0
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
131
owens
2.3000
0
No
0.36
NFRC
0.22
NFRC
Window
screens
Registration Number: 423-P010124990A-000-001-E01031A-0000 Registration Date/Time: 2023-07-20 07:24:36 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2023-07-20 07:24:36
Schema Version: rev 20190501
CERTIFICATE OF INSTALLATION CF2R-ENV-01-E
Fenestration Installation (Page 4 of 7)
A. Fenestration/ Glazing
Includes all Windows, Skylights, Greenhouse or Bay Windows and Glazed Doors.Note: If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 glass in door, it is assumed to
meet the minimum required U-factor (0.30) and SHGC (0.23).
If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 tubular skylight, it is assumed to meet the minimum required U-factor (0.55) and SHGC (0.30).
Doors with greater than or equal to 25 percent glazing area are considered glazed doors and are treated as fenestration products.
01
02
03
04
05
06
07
08
09
10
11
12
Manufacturer/
Fenestration
Fenestration
ExteriorComments/Sp
Tag ID
Brand
Area (ft)
Orientation
Chromogenic
U-factor
Source
SHGC
Source
Type
Shading
ecial Features
Devices
Standard bug
130
owens
2.3000
0
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
1032
owens
12.5000
90
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
124
owens
25.0000
180
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
123
owens
18.0000
180
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
122
owens
18.0000
180
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
133
owens
36.0000
270
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
1112
owens
4.0000
0
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
102
owens
22.5000
90
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
102d
owens
50.0000
90
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
101
owens
22.5000
90
No
0.36
NFRC
0.22
NFRC
Window
screens
Registration Number: 423-P010124990A-000-001-E01031A-0000 Registration Date/Time: 2023-07-20 07:24:36 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2023-07-20 07:24:36
Schema Version: rev 20190501
CERTIFICATE OF INSTALLATION CF2R-ENV-01-E
Fenestration Installation (Page 5 of 7)
A. Fenestration/ Glazing
Includes all Windows, Skylights, Greenhouse or Bay Windows and Glazed Doors.Note: If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 glass in door, it is assumed to
meet the minimum required U-factor (0.30) and SHGC (0.23).
If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 tubular skylight, it is assumed to meet the minimum required U-factor (0.55) and SHGC (0.30).
Doors with greater than or equal to 25 percent glazing area are considered glazed doors and are treated as fenestration products.
01
02
03
04
05
06
07
08
09
10
11
12
Manufacturer/
Fenestration
Fenestration
ExteriorComments/Sp
Tag ID
Brand
Area (ft)
Orientation
Chromogenic
U-factor
Source
SHGC
Source
Type
Shading
ecial Features
Devices
Standard bug
121
owens
8.0000
180
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
120
owens
22.5000
180
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
119
owens
6.0000
180
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
118
owens
6.0000
180
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
1102
owens
120.0000
270
No
0.36
NFRC
0.22
NFRC
Window
screens
Standard bug
1122
owens
190.0000
270
No
0.36
NFRC
0.22
NFRC
Window
screens
B. Fenestration Installation
01
The U-factor of the installed windows for new construction and existing buildings must be equal to or less than those listed on the CF1R.
02
The SHGC of the installed windows for new construction and existing buildings must be equal to or less than those listed on the CF1R in climate zones 2, 4 and 8-15. For climate zones 1,
3, 5 and 16 there is no SHGC requirement.
03
Temporary labels are not to be removed until verified by the building inspector.
Registration Number: 423-P010124990A-000-001-E01031A-0000 Registration Date/Time: 2023-07-20 07:24:36 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2023-07-20 07:24:36
Schema Version: rev 20190501
CERTIFICATE OF INSTALLATION CF2R-ENV-01-E
Fenestration Installation (Page 6 of 7)
B. Fenestration Installation
04 I The fenestration product manufacturer's installation specifications shall be followed when installing these products. The space between the fenestration product and rough opening
shall be completely filled with insulation. If batt insulation is used, it is cut to size and placed properly around the fenestration product.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
Registration Number: 423-P010124990A-000-001-E01031A-0000 Registration Date/Time: 2023-07-20 07:24:36 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2023-07-20 07:24:36
Schema Version: rev 20190501
CERTIFICATE OF INSTALLATION CF2R-ENV-01-E
Fenestration Installation (Page 7 of 7)
Documentation Author's Declaration Statement
1.1 certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tom Bachus
Company:
Signature Date:
MLC Building Performance
2023-07-20
Address:
CEA/ HERS Certification Identification (if applicable):
77825 Delaware Place
RCN10140
City/State/Zip:
Phone:
1760-360-0066
Palm Desert CA 92211
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Installation is true and correct.
2. 1 am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of
features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized
representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf.
3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the
installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency.
4. 1 will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all
applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Builder/Installer Name:
Responsible Builder/Installer Signature:
Austin Simmons
Company Name: (Installing Subcontractor or General Contractor or Builder/Owner)
Position With Company (Title):
Simmons Air
Address:
CSLB License:
41900 Yucca Ln
780534
City/State/Zip:
Phone:
Date Signed:
Bermuda Dunes CA 92203
7605785993
12023-07-20
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 423-P010124990A-000-001-E01031A-0000 Registration Date/Time: 2023-07-20 07:24:36 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2023-07-20 07:24:36
Schema Version: rev 20190501
CERTIFICATE OF INSTALLATION
CF2R-ENV-03-E
Insulation Installation
(Page 1 of 7)
Project Name: Traditions lot 26 Rippee new23
Enforcement Agency: La Quinta, City of
Permit Number:
2021
Dwelling Address: 78-761 Deacon Drive East
City: La Quinta
Zip Code:
92253
Medium and light density SPF manufacturers claim various R-values per inch. In California the maximum R-value that can be claimed for ccSPF is an R-value of 5.8 per inch and for ocSPF is an
R-value of 3.6 per inch unless documentation is provided showing that the product and/or manufacturer has a current ICC Evaluation Service Report (ESR) that shows compliance with Acceptance
Criteria for Spray -Applied Foam Plastic Insulation (AC-377).
Note: The Energy Standards Section 110.7 requires that 'all joints, penetrations and other openings in the building envelope that are potential sources of air leakage shall be caulked, gasketed,
weather stripped, or otherwise sealed to limit infiltration and exfiltration.' In areas where spray foam (SPF) insulation is used, the SPF can be considered the air barrier. Other than rigid board
insulation, all other forms of insulation are not considered as an air barrier.
A. Roof/Ceiling Insulation
01
02
03
04
05
06
07
08
09
10
Manufacturer and
Assembly/Framin
Assembly
Framing Size and
Core/Cavity
Insulation Depth
Continuous
I.D.
Brand
g Material
Thickness (inches)
Spacing
Insulation Type
ESR Number
Insulation R-value
(inches)
Insulation R-value
foam
N/A
Wood Framed
4
2x4 161nchOC
Fiberglass
n/a
0
0
0
Ceiling
Attic Roofprimary
SWD
Wood Framed
8.78
2x4 241nchOC
Spray Foam
n/a
30
8.3
0
bedroom
Ceiling
Insulation (SPF)
Attic
SWD
Wood Framed
8.78
2x4 241nchOC
Spray Foam
n/a
30
8.3
0
Roofbedroom 4
Ceiling
Insulation (SPF)
Attic
SWD
Wood Framed
8.78
2x4 241nchOC
Spray Foam
n/a
30
8.3
0
Roofbedroom 2
Ceiling
Insulation (SPF)
Attic Roofgreat
SWD
Wood Framed
8.78
2x4 241nchOC
Spray Foam
n/a
30
8.3
0
room
Ceiling
Insulation (SPF)
Registration Number: 423-P010124990A-000-001-E03001A-0000 Registration Date/Time: 2023-07-19 06:16:08 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2023-07-20 03:47:15
Schema Version: rev 20191201
CERTIFICATE OF INSTALLATION CF2R-ENV-03-E
Insulation Installation (Page 2 of 7)
B. Wall Insulation
01
02
03
04
05
06
07
08
09
10
Manufacturer and
Assembly/Framin
Assembly
Framing Size and
Core/Cavity
Insulation Depth
Continuous
I.D.
Brand
g Material
Thickness (inches)
Spacing
Insulation Type
ESR Number
Insulation R-value
(inches)
Insulation R-value
R-21 Wall
KANUF
Wood Framed
6.88
2x6 16lnchCC
Fiberglass
n/a
21
5.5
0
Walls
R-0 Interior Wall
N/A
Wood Framed
4.5
2x4 161nchCC
Cellulose
n/a
0
0
0
Walls
C. Mass Insulation
This section does not apply to this project.
D. Raised Floor Insulation
This section does not apply to this project.
E. Slab Floor/Perimeter Insulation (See Section F. For Insulation Requirements For Heated Slabs)
This section does not apply to this project.
F. Heated Slabs Insulation
01
All heated slabs shall be insulated as required by Section 110.8(g). Footings must meet required insulation levels.
02
Insulation shall be installed from the top of the slab, down 16 inches or to the frost line, whichever is greater. Climate zones 1-15 require R-5, and climate zone 16 requires R-10.
03
Alternatively, vertical insulation from top of slab at inside edge of outside wall down to the top of the horizontal insulation. Horizontal insulation from the outside edge of the vertical
insulation extending 4 feet toward the center of the slab in a direction normal to the outside of the building in plain view. Climate zones 1-5 require R-5, and climate zone 16 requires
R-10 vertical and R-7 horizontal.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
Registration Number: 423-P010124990A-000-001-E03001A-0000 Registration Date/Time: 2023-07-19 06:16:08 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2023-07-20 03:47:15
Schema Version: rev 20191201
CERTIFICATE OF INSTALLATION CF2R-ENV-03-E
Insulation Installation (Page 3 of 7)
G. Minimum Mandatory Measures
01
Insulation - 110.8(a): All installed Insulation is certified and listed with Department of Consumer Affairs, "Standards for Insulating Material".
02
Insulation - 110.8(b): Urea formaldehyde foam insulation is protected by 4 mil polyethylene vapor retarder.
03
Insulation - 110.8(c): Flame spread and smoke density requirements of CBC are met.
04
Raised Floor - 150.0(d): All raised wood -frame floor have a minimum R-19 insulation or equivalent U-factor
Slab Floor/Perimeter - 150.0(1): Water absorption rate for the insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0
05
perm/inch and is protected from physical damage and UV light deterioration.
06
Above Grade Exterior Wall - 150.0(c)1 and 150.1(c)6: All 2x4 wood -frame walls have a minimum R-13 insulation or equivalent U-factor not exceeding U-0.102.
07
Above Grade Exterior Wall - 150.0(c)2 and 150.1(c)6: All 2x6 wood -frame walls have a minimum R-20 insulation or equivalent U-factor not exceeding U-0.071.
08
Ceiling/Rafter Roof - 150.0(a)1: All wood -frame ceiling have a minimum R-22 insulation or equivalent U-factor.
09
Vapor Retarder - 150(g)1: In Climate Zones 1 through 16, the earth floor of unvented crawl space shall be covered with a Class I or Class II vapor retarder. This requirement shall also
apply to controlled ventilation crawl space for buildings complying with the Exception to Section 150.0(d).
10
Vapor Retarder - 150(g)2: In Climate Zones 14 and 16, a Class I or Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior walls, vented attics
and unvented attics with air -permeable insulation.
Heated Slabs - 110.8(g): All heated slabs shall be insulated as required.
• Insulation shall be installed from the top of the slab, down 16 inches or to the frost line, whichever is greater. Climate zones 1-5 require R-5, and climate zone 16 requires R-10.
11
Alternatively, vertical insulation from top of slab at inside edge of outside wall down to the top of the horizontal insulation. Horizontal insulation from the outside edge of the
vertical insulation extending 4 feet toward the center of the slab in a direction normal to the outside of the building in plain view. Climate zones 1-5 require R-5, and climate zone
16 requires R-10 vertical and R-7 horizontal.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
H. Installed Insulation
01
Installed insulation R-values are the same or greater than listed on the CF1R.
02
No gaps or voids between the insulation and framing.
03
No gaps between the sides or ends of batt insulation.
Registration Number: 423-P010124990A-000-001-E03001A-0000 Registration Date/Time: 2023-07-19 06:16:08 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2023-07-20 03:47:15
Schema Version: rev 20191201
CERTIFICATE OF INSTALLATION CF2R-ENV-03-E
Insulation Installation (Page 4 of 7)
H. Installed Insulation
04
Loose -fill insulation must be installed to the minimum installed weight per square foot (density) of the manufacturer's cut sheet for the proposed R-value.
05
Batt insulation is not compressed (no stuffing of the insulation into the cavity) and is installed to its full thickness.
06
Insulation is cut around obstructions such as electrical boxes.
07
Batt insulation is delaminated around all plumbing and electrical lines in ceilings, walls and floors.
08
Band joists are insulated to the same R-value as the wall.
09
In all narrow cavities the insulation shall be cut to fit or filled with expanding foam.
10
Insulation was installed per manufacturer instructions.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
I. Wall Insulation
01
When allowed by manufacturer, low expanding foam shall be used to fill gaps and voids around windows and doors. If not, the cavity must be air tight and filled completely with
insulation. Batt insulation must be cut to width. No stuffing allowed.
02
Install wall insulation before installing tubs, showers and fireplaces.
03
Electric panels on walls separating conditioned and unconditioned space are sealed and insulated behind the panel with rigid insulation or expanding foam.
04
All walls of interior closets vented to the outside for HVAC or water heating equipment have the same R-value and air barrier as the exterior walls and ceiling. Doors are insulated and
weather stripped.
05
Ducting not allowed in exterior walls unless insulated to R6 or greater and the insulation and duct are not crushed. Ducting not allowed in 2x4 wall assemblies.
06
Corner channels, wall intersections, and double sided shear walls insulated to the required R-value before enclosing the wall.
07
Insulation that does not fill the cavity placed against exterior air barrier.
08
Band joists are insulated to the same R-value as the walls.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
Registration Number: 423-P010124990A-000-001-E03001A-0000 Registration Date/Time: 2023-07-19 06:16:08 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2023-07-20 03:47:15
Schema Version: rev 20191201
CERTIFICATE OF INSTALLATION CF2R-ENV-03-E
Insulation Installation (Page 5 of 7)
J. Ceiling Roof Insulation
01
Insulation extends to the outside edge of the exterior top plates and is flush against any ventilation dams/baffles.
02
Insulation is in direct contact with ceiling, so there are no gaps between the ceiling and the insulation.
03
For chimneys and flues, the insulation is in contact with the sheet metal collar.
04
Can lights are covered with insulation to the same depth as required by the CF1R for ceiling insulation. If not an area weighted calculation is required to be turned in with this
compliance document.
05
Walkways and mechanical platforms insulated to the same R-value as required for the ceiling. If not an area weighted calculation is required to be turned in with this compliance
document.
06
Insulate soffits by adding an air barrier and cover with insulation, or insulate the entire soffit including floor and walls.
07
Knee walls and skylight shafts are insulated to the wall R-value and in full contact with the interior air barrier. If framing on these surfaces is laid flat batt insulation is cut to fit around
the framing. Batt insulation is not allowed to be draped over the framing.
08
Attic access doors insulated to the same R-value as ceiling. The insulation is permanently attached using adhesive or mechanical fasteners.
09
Attic access must be surrounded with a dam at least the same depth as the insulation to prevent loss of ceiling insulation.
10
Batt insulation cut to fit around cross bracings and truss webs in attic.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
K. Raised Floor Insulation
01
Insulation in full contact with subfloor.
02
Insulation hangers spaced at 18 inches or less, insulation hangers must not compress insulation.
03
If netting or mesh is used, the cavity under the floor is filled and in contact with the subfloor.
04
If the basement is conditioned the walls adjacent to the crawlspace must meet minimum wall R-value requirements. This includes framed stem walls, and vertical concrete retaining
walls.
05
If access to the crawl space is from the conditioned area, the raised floor must have an airtight insulated access hatch.
Registration Number: 423-P010124990A-000-001-E03001A-0000 Registration Date/Time: 2023-07-19 06:16:08 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2023-07-20 03:47:15
Schema Version: rev 20191201
CERTIFICATE OF INSTALLATION CF2R-ENV-03-E
Insulation Installation (Page 6 of 7)
K. Raised Floor Insulation
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
L. Floor Above Garage Insulation
01
Insulation must be in full contact with subfloor if the air barrier is at the band joist at the garage/house wall.
02
Insulation hangers spaced at 18 inches or less, insulation hangers must not compress insulation.
03
If netting or mesh is used, the cavity under the floor is filled and in contact with the subfloor.
04
If air barrier is at the perimeter of the garage, below conditioned subfloor, the insulation is placed on the garage ceiling. The perimeter of subfloor is also insulated.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
M. Cantilevered Floor Insulation
01
Insulation in full contact with cantilevered subfloor. Insulation hangers spaced at 18 inches or less, insulation hangers do not compress insulation.
02
If netting or mesh is used, the cavity under the floor is filled and in contact with the subfloor.
03
Sealed blocking is installed between joists where wall rim joist would be located in the absence of a cantilever. Insulation is placed on both sides of this block.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
N. Attached Porch Roof Insulation
01
The exterior insulated wall at the intersection with the porch roof is fully insulated above, below and behind the roof line.
02
Where truss framing is used, airtight blocking is at the top and bottom of each wall/roof section and insulated.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
Registration Number: 423-P010124990A-000-001-E03001A-0000 Registration Date/Time: 2023-07-19 06:16:08 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2023-07-20 03:47:15
Schema Version: rev 20191201
CERTIFICATE OF INSTALLATION CF2R-ENV-03-E
Insulation Installation (Page 7 of 7)
Documentation Author's Declaration Statement
1. 1 certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Maria Saldana
' cuSaIzZzwzil
Company:
Signature Date:
TruTeam of California
2023-07-19
Address:
CEA/ HERS Certification Identification (if applicable):
260 Jimmy Ann Drive
City/State/Zip:
Phone:
1386-304-2222
Daytona Beach FL 32114
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Installation is true and correct.
2. 1 am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of
features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized
representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf.
3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the
installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency.
4. 1 will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all
applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Builder/Installer Name:
Responsible Builder/Installer Signature:
Maria Saldana
Company Name: (Installing Subcontractor or General Contractor or Builder/Owner)
Position With Company (Title):
TruTeam of California
Address:
CSLB License:
260 Jimmy Ann Drive
1034361
City/State/Zip:
Phone:
Date Signed:
Daytona Beach FL 32114
386-304-2222
12023-07-19
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 423-P010124990A-000-001-E03001A-0000 Registration Date/Time: 2023-07-19 06:16:08 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2023-07-20 03:47:15
Schema Version: rev 20191201
CERTIFICATE OF INSTALLATION CF2R-ENV-04-E
Roofing Radiant Barrier (Page 1 of 5)
Project Name: Traditions lot 26 Rippee new23
Enforcement Agency: La Quinta, City of
Permit Number: 2021
Dwelling Address: 78-761 Deacon Drive East
City: La Quinta
Zip Code: 92253
A. General Information
01
Construction Type
Cathedral Ceilings
02
Total Attic Area (ftz)
2000
03
Radiant Barrier Installed?
Yes
04
Attic Space Ventilated or Unventilated?
Ventilated
05
Minimum Ventilation Method of Compliance
n/a
Note: in order to comply with the 1/300 exception, a Class I or II vapor retarder is required to be installed in climate zone 14 and 16.
B. Radiant Barrier
01
Brand Name and product number
02
Installation Type
Attached between truss/rafters, stapled to each side
C. Schedule of Lower Vents
The Net Free Area (NFA) of a manufactured product is stated on the packaging or on the manufacturer's specification data sheet. For non -manufactured products, assume that
the net free area is one third of the total aperture area.
01
02
03
04
Type of Vent For instance, eyebrow vent, eave vent, round vent
NFA per vent (in2) (Manufacturer's
Number of Vents Installed
Total NFA Per Vent Type (in)
Specification Sheet)
Other
100
10
1000
Registration Number: 423-P010124990A-000-001-E04030A-0000 Registration Date/Time: 2023-07-20 07:24:35 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2023-07-20 07:24:36
Schema Version: rev 20191201
CERTIFICATE OF INSTALLATION CF2R-ENV-04-E
Roofing Radiant Barrier (Page 2 of 5)
D. Schedule of Upper Vents
The Net Free Area of a manufactured product is stated on the packaging or on the manufacturer's specification data sheet. For non -manufactured products, assume that the
net free area is one third of the total aperture area.
01
02
03
04
Type of Vent (For instance, eyebrow vent, eave vent, round
NFA per vent (inZ)/Per Linear Foot
Number of Vents/Linear Feet Installed
Total NFA Per Vent Type (in)
vent, ridge vent)
(Manufacturer's Specification Sheet)
Other
100
10
1000
E. Required Vent Area
01
Combined NFA of installed upper and lower vents (inZ)
2000
02
Minimum required combined NFA of upper and lower vents (inZ)
960
03
NFA of installed upper vents (inZ)
1000
04
Minimum required NFA of upper vents (inZ)
288
05
Compliance Statement
Building complies
F. Radiant Barrier - Additional Requirements
Radiant Barrier
01
Radiant barrier must be installed on all vertical surfaces in the attic including gable ends.
02
The emittance of the radiant barrier shall be less than or equal to 0.05 as tested with ASTM C1371, or E408.
03
The product shall meet all requirements for California certified insulation materials (radiant barriers) of the Department of Consumer Affairs, Bureau of Electronic and Appliance Repair,
Home Furnishings and Thermal Insulation, as specified by CCR, Title 24, Part 12, Chapter 12-13, Standards for Insulating Material
04
When determining the Total Attic Area, the area over unconditioned spaces such as the garage is included when the attic spaces are connected
Registration Number: 423-P010124990A-000-001-E04030A-0000 Registration Date/Time: 2023-07-20 07:24:35 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2023-07-20 07:24:36
Schema Version: rev 20191201
CERTIFICATE OF INSTALLATION CF2R-ENV-04-E
Roofing Radiant Barrier (Page 3 of 5)
G. Attic Ventilation - Additional Requirements
Lower Vents
01
Lower vents are within one foot of the eave.
Upper Vents
02
Upper vents are within three feet of the ridge.
Vent Area
03
The NFA of upper vents must be within required NFA range of upper vents
Note: per Exception to R806.2 of the CBC Title 24, Part2, Vol.2.5, if the net free ventilating area is less than 1:150, then the upper ventilation must be at least 40% and no more than
50%. Part 2 contains additional requirements that must be met if the area is less than 1:150.
The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met.
H. Roofing Products (Cool Roof) Installation Information
01
02
03
04
05
06
07
08
09
10
11
12
CRRC Listed
Installed
Required
Tag/ID
Roof Pitch
CRRC Product
ID Number
Product type
Aged Solar
Initial Solar
Aged Solar
Thermal
Aged Solar
Thermal
Reflectance
Reflectance
Reflectance
Emittance
SRI
Reflectance
Emittance
SRI
Attic primary
Roof pitch is
Clay roof tiles
No
6
6
5
635367888
0.7
0.86
bedroom
>= 2 :12
Attic bedroom
Roof pitch is
Clay roof tiles
No
6
5
5
635367888
0.7
0.86
4
>= 2 :12
Attic bedroom
Roof pitch is
Clay roof tiles
No
.6
.5
.5
635367888
0.7
0.86
2
>_ 2 .12
Attic great
Roof pitch is
Clay roof tiles
Yes
6
.5
.5
635367888
0.7
0.86
635367888
room
>= 2 :12
I. Roofing Products (Cool Roof) - Additional Requirements
01
Any roof area covered by building integrated photovoltaic panels and solar thermal panels are exempt from the above Cool Roof requirements
Registration Number: 423-P010124990A-000-001-E04030A-0000 Registration Date/Time: 2023-07-20 07:24:35 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2023-07-20 07:24:36
Schema Version: rev 20191201
CERTIFICATE OF INSTALLATION CF2R-ENV-04-E
Roofing Radiant Barrier (Page 4 of 5)
I. Roofing Products (Cool Roof) - Additional Requirements
02
Liquid field applied coatings must comply with installation criteria from section 110.8(i)4
03
Mass roof 25 Ib/ftz or greater: Mass roofs are not required to have a cool roof even if the climate zone specifies minimum performance requirements
The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met.
Registration Number: 423-P010124990A-000-001-E04030A-0000 Registration Date/Time: 2023-07-20 07:24:35 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2023-07-20 07:24:36
Schema Version: rev 20191201
CERTIFICATE OF INSTALLATION CF2R-ENV-04-E
Roofing Radiant Barrier (Page 5 of 5)
Documentation Author's Declaration Statement
1.1 certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tom Bachus
Company:
Signature Date:
MLC Building Performance
2023-07-20
Address:
CEA/ HERS Certification Identification (if applicable):
77825 Delaware Place
RCN10140
City/State/Zip:
Phone:
1760-360-0066
Palm Desert CA 92211
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Installation is true and correct.
2. 1 am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of
features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized
representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf.
3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the
installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency.
4. 1 will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all
applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Builder/Installer Name:
Responsible Builder/Installer Signature:
Austin Simmons
Company Name: (Installing Subcontractor or General Contractor or Builder/Owner)
Position With Company (Title):
Simmons Air
Address:
CSLB License:
41900 Yucca Ln
780534
City/State/Zip:
Phone:
Date Signed:
Bermuda Dunes CA 92203
7605785993
12023-07-20
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 423-P010124990A-000-001-E04030A-0000 Registration Date/Time: 2023-07-20 07:24:35 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2023-07-20 07:24:36
Schema Version: rev 20191201