BRES2021-0834Description: PACIFIC VIEW ESTATES/ 4,241SF DWELLING/VB/R-3/CLASS A-FR/13D
Type: BUILDING RESIDENTIAL Subtype: DWELLING - SINGLE Status: FINALED
Applied: 11/30/2021 ECON
(WEB) FAMILY DETACHED
Approved: 4/12/2022 JFU
Parcel No: 770230016 Site Address: 78761 DEACON DR E ,CA
Subdivision: TR 28470-1 Block: Lot: 26
Issued: 4/14/2022 AHI
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Finaled: 7/26/2023 JAN
Valuation: $385,668.00 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: 4,241SF SINGLE FAMILY DWELLING - [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE PV SYSTEM, POOL, SPA, BLOCK
WALLS, DRIVEWAY APPROACH OR OTHER SIMILAR EXTERIOR STRUCTURES. 2019 CALIFORNIA BUILDING CODES.
REVISION 1- SOLAR PV SYSTEM UPDATES + BUILDING ENVELOPE INSULATION CHANGE.
469
2 133
Applied to Approved
Approved to Issued
_j Issued to Finaled
ADDITIONAL
CHRONOLOGY
CHRONOLOGY TYPE STAFF NAME
ACTION DATE COMPLETION DATE NOTES
- NOTIFIED APPLICANT THAT NO TRUSS PACKAGE HAS BEEN
E-MAIL
DUANE CLAYTON
9/16/2022
9/16/2022
SUBMITTED FOR REVIEW AND APPROVAL. APPLICANT TO
RESCHEDULE ROOF NAIL AFTER TRUSSES HAVE BEEN
SUBMITTED, REVIEWED, AND APPROVED.
E-MAIL
JAKE FUSON
1/27/2022
1/27/2022
NOTIFIED APPLICANT OF 1ST REVIEW COMMENTS, SENT
CORRECTION LIST VIA EMAIL.
NOTIFIED APPLICANT THAT THE ONLY COMMENT FROM THE
E-MAIL
JAKE FUSON
4/12/2022
4/12/2022
2ND ROUND OF REVIEWS IS TO PROVIDE A FOUNDATION
PLAN REVIEW LETTER AS REQUESTED BY THE STRUCTURAL
REVIEWER. ALSO SENT CONDITIONS FOR ISSUANCE.
E-MAIL
JAKE FUSON
9/22/2022
9/22/2022
NOTIFIED APPLICANT THAT DEFERRED TRUSS DESIGNS ARE
APPROVED AND READY FOR PAYMENT.
E-MAIL
JAKE FUSON
7/17/2023
7/17/2023
NOTIFIED APPLICANT & OWNER OF REVISION 1 - 2ND REVIEW
COMMENTS.
Printed: Tuesday, October 17, 2023 10:15:30 AM 1 of 22
WSYSiEMS
NOTIFIED APPLICANT THAT REVISION 1 IS APPROVED AND
E-MAIL
JAKE FUSON
7/20/2023
7/20/2023
READY FOR FEE PAYMENT.
PUBLIC COUNTER VISIT
JACK LIMA
12/13/2022
12/13/2022
PENDING SUBCONTRACTOR LIST
RESUBMITTAL
JAKE FUSON
3/1/2022
3/1/2022
2ND SUBMITTAL RECEIVED VIA ETRAKIT. NO GREEN SHEET
RECEIVED SO PW REVIEW WILL NOT BE SCHEDULED.
CONDITIONS
CONDITION
DATE
DATE
DATE
CONTACT
STATUS
REMARKS
NOTES
TYPE
ADDED
REQUIRED
SATISFIED
THE FOLLOWING ARE REQUIRED PRIOR TO
PERMIT ISSUANCE:
-FOUNDATION PLAN REVIEW LETTER
READY TO ISSUE
JAKE FUSON
4/12/2022
4/14/2022
4/14/2022
COMPLETE
-GRANT DEED
CHECKLIST
-SCHOOL FEE PAYMENT
UPDATE: GRANT DEED AND FOUNDATION PLAN
REVIEW LETTER RECEIVED. SCHOOL FEE
PAYMENT STILL OUTSTANDING.
CONTACTS
NAME TYPE
NAME
ADDRESSI
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
JAMES DEFORD
MISSION
CA
91691
(
CONTRACTOR
JEFF RIPPEE
52700 AVENIDA
LA QUINTA
CA
92253
(619)972-4545
JRIPPEE@PACIFICVIEW
VALLEJO
ESTATESINC.COM
CONTRACTOR
SUNROSE CORPORATION
72850 SOMERA RD
PALM DESERT
CA
92260
(619)972-4545
SUNROSE.SEDONA@G
(HISTORY)
MAIL.COM
OWNER
PACIFIC VIEW ESTATES INC
atesinc.com
Printed: Tuesday, October 17, 2023 10:15:30 AM 2 of 22
WSYSiEMS
CLTD
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
2.5 CREDIT CARD
101-0000-43505
0
$2.18
$2.18
1/4/23
R73891
393584
DEBIT
JEFF RIPPEE
AHI
PROCESSING FEE
Total Paid for 2.5 CREDIT CARD PROCESSING FEE: $2.18 $2.18
CHANGE OF
CONTR/ARCH/OWNER
101-0000-42600
0
$117.30
$117.30
12/13/22
R73632
769729112
CREDIT
JEFF RIPPEE
EMO
PROCESSING
PARTIAL INSPECTION
101-0000-42400
0
$87.53
$87.53
12/7/22
WEB13780
765937640
CREDIT
533670
ECON
FEE
RE -INSPECTION FEE
101-0000-42400
0
$87.53
$87.53
1/4/23
R73891
393584
DEBIT
JEFF RIPPEE
AHI
Total Paid for ADMINISTRATIVE: $292.36 $292.36
ART IN PUBLIC PLACES -
270 0000 43201
0
$464.17
$464.17
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
RESIDENTIAL
9
ESTATESINC
Total Paid for ART IN PUBLIC PLACES - AIPP: $464.17 $464.17
HOURLY CHARGE - CITY
101-0000-42600
1
$167.00
$167.00
9/22/22
WEB13131
729603242
CREDIT
533670
ECON
BUILDING STAFF
HOURLY CHARGE - CITY
101-0000-42600
0.5
$87.50
$87.50
6/30/23
WEB15589
111133314
CREDIT
AEC1219
ECON
BUILDING STAFF
1
HOURLY CHARGE - CITY
101-0000-42600
2
$350.00
$350.00
7/20/23
WEB15771
112380840
CREDIT
AEC1219
ECON
BUILDING STAFF
2
Total Paid for BLDG CITY STAFF - PER HOUR: $604.50 $604.50
BSAS SB1473 FEE
101-0000-20306
0
$16.00
$16.00
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
Total Paid for BUILDING STANDARDS ADMINISTRATION
$16.00 $16.00
BSA:
DIF - CIVIC CENTER
252-0000-43200
0
$1,230.00
$1,230.00
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
DIF - COMMUNITY
254-0000-43200
0
$956.00
$956.00
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
CULTURAL
9
ESTATESINC
Printed: Tuesday, October 17, 2023 10:15:30 AM 3 of 22
WSYSiEMS
■
CLTD
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
DIF - FIRE PROTECTION
257-0000-43200
0
$369.00
$369.00
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
DIF - LIBRARY
253-0000-43200
0
$397.00
$397.00
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
DIF - MAINTENANCE
259-0000-43200
0
$313.00
$313.00
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
FACILITIES
9
ESTATESINC
DIF - PARK
251-0000-43200
0
$2,106.00
$2,106.00
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
IMPROVEMENTS
9
ESTATESINC
DIF - TRANSPORTATION
250-0000-43200
0
$4,009.00
$4,009.00
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
Total Paid for DIF - SINGLE FAMILY DWELLING 2020: $9,380.00 $9,380.00
RESIDENTIAL, EA
101-0000-42403
0
$70.85
$70.85
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
ADDITIONAL 1,000SF
9
ESTATESINC
RESIDENTIAL, EA
101-0000-42600
0
$29.20
$29.20
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
ADDITIONAL 1,000SF PC
9
ESTATESINC
RESIDENTIAL, FIRST
101-0000 42403
0
$166.73
$166.73
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
1,000SF
9
ESTATESINC
RESIDENTIAL, FIRST
101 0000 42600
0
$55.02
$55.02
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
1,000SF PC
9
ESTATESINC
Total Paid for ELECTRICAL - NEW CONSTRUCTION 2021: $321.80 $321.80
TEMP POWER SERVICE
101-0000-42403
0
$27.79
$27.79
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
TEMP POWER SERVICE
101-0000 42600
0
$19.45
$19.45
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
PC
9
ESTATESINC
Total Paid for ELECTRICAL 2021: $47.24 $47.24
FIRE NEW RESIDENITIAL
101 0000 42420
0
$83.00
$83.00
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
PC
9
ESTATESINC
FIRE NEW RESIDENTIAL
101-0000-42421
0
$83.00
$83.00
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
Total Paid for FIRE FEES: $166.00 $166.00
Printed: Tuesday, October 17, 2023 10:15:30 AM 4 of 22
WSYSiEMS
■
CLTD
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
RESIDENTIAL - CUSTOM
101-0000-42408
0
$41.68
$41.68
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
HOME >7KSF
9
ESTATESINC
RESIDENTIAL - CUSTOM
101-0000-42600
0
$208.41
$208.41
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
HOME >7KSF PC
9
ESTATESINC
Total Paid for GRADING 2021: $250.09 $250.09
CONDENSER/COMPRES
175701883
PACIFIC VIEW
101-0000 42402
0
$166.72
$166.72
4/14/22
R70008
CHECK
AHI
SOR
9
ESTATESINC
CONDENSER/COMPRES
101-0000 42600
0
$111.16
$111.16
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
SOR PC
9
ESTATESINC
EXHAUST HOOD
101-0000-42402
0
$13.89
$13.89
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
EXHAUST HOOD PC
101-0000-42600
0
$5.56
$5.56
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
FURNACE
101-0000-42402
0
$166.72
$166.72
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
FURNACE PC
101-0000-42600
0
$111.16
$111.16
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
VENT FAN
101-0000-42402
0
$111.12
$111.12
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
VENT FAN PC
101-0000-42600
0
$44.48
$44.48
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
Total Paid for MECHANICAL 2021: $730.81 $730.81
MULTI -SPECIES
RESIDENTIAL 0-8 UNITS
101-0000-20310
0
$1,400.00
$1,400.00
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
-2021 UPDATE
Total Paid for MULTI -SPECIES RESIDENTIAL: $1,400.00 $1,400.00
NEW CONSTRUCTION
101-0000 42400
0
$2,882.09
$2,882.09
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
PERMIT 2021
9
ESTATESINC
Total Paid for NEW CONSTRUCTION PERMIT 2021: $2,882.09 $2,882.09
Printed: Tuesday, October 17, 2023 10:15:30 AM 5 of 22
WSYSiEMS
■
CLTD
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
NEW CONSTRUCTION
101 0000 42600
0
$1,878.50
$1,878.50
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
PLAN CHECK 2021
9
ESTATESINC
Total Paid for NEW CONSTRUCTION PLAN CHECK 2021: $1,878.50 $1,878.50
BUILDING SEWER
101-0000-42401
0
$27.79
$27.79
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
BUILDING SEWER PC
101-0000-42600
0
$19.45
$19.45
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
FIXTURE/TRAP
101-0000-42401
0
$305.58
$305.58
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
FIXTURE/TRAP PC
101-0000-42600
0
$305.58
$305.58
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
GAS SYSTEM, 5+
101-0000-42401
0
$41.68
$41.68
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
OUTLETS
9
ESTATESINC
GAS SYSTEM, 5+
101 0000 42600
0
$27.78
$27.78
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
OUTLETS PC
9
ESTATESINC
ROOF DRAIN
101-0000-42401
0
$41.67
$41.67
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
ROOF DRAIN PC
101-0000-42600
0
$41.67
$41.67
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
WATER HEATER/VENT
101-0000-42401
0
$27.78
$27.78
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
WATER HEATER/VENT
101-0000 42600
0
$16.68
$16.68
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
PC
9
ESTATESINC
WATER SYSTEM
101 0000 42401
0
$13.89
$13.89
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
INST/ALT/REP
9
ESTATESINC
WATER SYSTEM
101-0000-42600
0
$13.89
$13.89
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
INST/ALT/REP PC
I
1
19
ESTATESINC
Total Paid for PLUMBING 2021: $883.44 $883.44
Printed: Tuesday, October 17, 2023 10:15:30 AM 6 of 22
WSYSiEMS
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
RECORDS
MANAGEMENT FEE -
101-0000-42416
0
$21.00
$21.00
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
MAJOR
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00
SMI - RESIDENTIAL
101-0000-20308
0
$50.14
$50.14
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $50.14 $50.14
TECHNOLOGY
502-0000-43611
0
$5.00
$5.00
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
ENHANCEMENT FEE
9
ESTATESINC
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
TUMF 2021- SINGLE
224-0000-20320
0
$2,358.00
$2,358.00
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
FAMILY DWELLING
9
ESTATESINC
Total Paid for TUMF 2021: $2,358.00 $2,358.00
NEW CONSTRUTION -
SINGLE FAMILY
101-0000-42400
0
$161.00
$161.00
4/14/22
R70008
175701883
CHECK
PACIFIC VIEW
AHI
9
ESTATESINC
RESIDENTIAL
Total Paid for ZONING CLEARANCE - PLANNING PLAN $161.00 $161.00
CHECK:
SEQID
INSPECTION TYPE
INSPECTOR
SCHEDULED
ED
CO7DATE
RESULT
REMARKS
NOTES
DATE
7.OkW PV SYSTEM REQUIRED PER
DEFERRED SUBMITTAL
NOT READY
PV SYSTEM
APPROVED ENERGY REPORT.
- CALL IN SEWER TIE-IN AND FLOW TEST
UNDERGROUND PLBG
DCL
5/18/2022
5/18/2022
APPROVED
WHEN READY.
Printed: Tuesday, October 17, 2023 10:15:30 AM 7 of 22
WSYSiEMS
Pad footings where steel columns are
required and grade beans, will be blocked
off and concrete will be placed once
templates have received dry pack approval.
FOOTINGS
BBL
6/10/2022
6/10/2022
PARTIALLY
OK to place concrete at pad template to
APPROVED
allow for dry pack instal lation.AlI other
footings are approved, OK to continue.Ufer
ground noted at time of inspection.Top of
form to the uploaded to system.Deputy
report to supplied at next inspection.
Slabs are approved.
Pads where steel columns is required and
grade beam footings, will be blocked off and
poured at another time, once template has
been approved for dry pack. OK to place
SLAB
BBL
6/10/2022
6/10/2022
PARTIALLY
concrete to bottom of template at this time.
APPROVED
All remaining footings and pads are
approved, OK to proceed.
Top of form will be uploaded in system.
Deputy report to follow.
TEMPLATE FOOTING
DCL
8/3/2022
8/3/2022
APPROVED
- TWO I -BEAM FOOTINGS. FULL TEMPLATE
APPROVAL.
9/15/2022 3:54 PM SUNROSE
CORPORATION
ROOF NAIL
DCL
9/16/2022
9/16/2022
CANCELED
eTRAKiT Inspection
Contact Name: SUNROSE CORPORATION
Request
Site Address: 78761 DEACON DR E
Phone:4423242298
e-Mail: SUNROSE.SEDONA@GMAIL.COM
Printed: Tuesday, October 17, 2023 10:15:30 AM 8 of 22
WSYSiEMS
- FOR TRUSS PACKAGE REQUIRED TO BE
ROOF NAIL
DCL
9/16/2022
9/16/2022
CANCELED
eTRA e Inspection
UPLOADED FOR REVIEW AND APPROVAL.
R
Request
NOTIFIED APPLICANT - SEE CHRONOLOGY.
DEFERRED TRUSS
JFU
9/22/2022
9/22/2022
APPROVED
TRUSS DESIGNS APPROVED 9/22/2022.
ROOF NAIL
JAN
9/23/2022
9/23/2022
APPROVED
OKAY TO WRAP
JAN
10/19/2022
10/19/2022
PARTIALLY
Re -call for inspection once windows are
APPROVED
installed and flashed, u factors to be verified
LATH
MHU
11/8/2022
11/8/2022
DISAPPROVE
WORK COVERED PRIOR TO APPROVAL FOR
D
OK TO WRAP
- BOTTOM FLASHING VERIFIED AT
EXTERIOR, AND COUNTER AND UPPER
FLASHING VERIFIED AT DOUBLE FRAMED
AREAS. WORK APPEARS TO CONFORM TO
LATH
DCL
11/15/2022
11/15/2022
PARTIALLY
TYPICAL STANDARDS.- EXCLUDES REAR
APPROVED
DOORS, LATH INCOMPLETE AT THIS AREA AT
TIME OF INSPECTION.- PARTIAL INSPECTION
FEE ASSESSED. REQUEST LATH INSPECTION
FOR REAR OF DWELLING WHEN READY.
OKAY TO WRAP
DCL
11/15/2022
11/15/2022
APPROVED
- NFRC LABELS VERIFIED. FULL APPROVAL
FOR OK TO WRAP.
At site, sewer system is not ready for test, no
water noted in sewer connections. As
SEWER CONNECTION
BBL
12/8/2022
12/8/2022
NOT READY
discussed with owner, at next inspection
water will be installed as well as someone to
remove the bladder for testing.
SEWER CONNECTION
BBL
12/8/2022
12/8/2022
CANCELED
Duplicate inspection.
SEWER CONNECTION
JFU
12/13/2022
12/13/2022
APPROVED
Changes in head location as well as riser
OVERHEAD ROUGH
LIN
1/24/2023
1/24/2023
APPROVED
AS BUILTS REQUIRED
location. Premature insulation was partially
PIPING
removed to observed all sprinkler system
components. As builts required.
Printed: Tuesday, October 17, 2023 10:15:30 AM 9 of 22
WSYSiEMS
FRAMING
JFU
1/27/2023 1
1/27/2023
DISAPPROVE
D
-OBTAIN SOLAR PERMIT AND GET ROUGH
ELECTRICAL INSPECTION APPROVED
-PROVIDE STRUCTURAL OBSERVATION
REPORT FORM FOR
-PROVIDE FIREBLOCKING AT DOUBLE
FRAMED WALLS THROUGHOUT, SEVERAL
LOCATIONS
-SEPARATE THE ROMEX AT CONNECTORS AT
ALL PANELS (TYPICALLY 2 PER CONNECTOR)
-PROVIDE NAIL PLATES AT PLASTIC PIPING
WITHIN 3/4" OF FACE OF FRAMING
(GARAGE, MASTER CLOSET AND KITCHEN)
-LOOSE HOLD DOWN NUT AT GARAGE
(COLUMN BETWEEN GARAGE DOORS)
-ANCHOR BOLTS MISSING AT SOLE PLATE
BREAKS AT SEVERAL LOCATIONS
-INSTALL RODENTPROOFING AT SOLE
PLATES AT GARAGE, BED 3, LAUNDRY
-STRAP ROMEX AT BEDROOM 3 WITHIN 12"
OF BOX
-LOOSE NUTS AT BEDROOM 3 CLOSET,
ANCHOR BOLTS MISSING PER SHEAR WALL
SCHEDULE, SPECIAL INSPECTION REQUIRED
FOR EPDXY
-INSTALL POLY SEAL
-INSTALL TEMPERATURE & PRESSURE VALVE
PIPING AT WATER HEATERS
-INSTALL GROUND SCREWS AT METAL
BOXES
-ADDRESS HOLES IN SHEAR WALL AT BATH 2
SHOWER
-NM MUST BE SECURED AT EXHAUST FAN
ENCLOSURES
-VERIFY LIGHT AND SWITCH AT ATTIC WINE
UNIT
-INSTALL CLEANOUT ON FOOT VENT OF
ISLAND VENT
-LAND LOOSE ROMEX AT FIREPLACES
Printed: Tuesday, October 17, 2023 10:15:30 AM 10 of 22
RWSYSiEMS
SEE FRAMING INSPECTION NOTES FOR
ROUGH ELEC
JFU
1/27/2023
1/27/2023
DISAPPROVE
COMPLETE LIST OF FRAMING COMBO
D
CORRECTIONS.
SEE FRAMING INSPECTION NOTES FOR
ROUGH MECH
JFU
1/27/2023
1/27/2023
DISAPPROVE
COMPLETE LIST OF FRAMING COMBO
D
CORRECTIONS.
SEE FRAMING INSPECTION NOTES FOR
ROUGH PLBG
JFU
1/27/2023
1/27/2023
DISAPPROVE
COMPLETE LIST OF FRAMING COMBO
D
CORRECTIONS.
LATH
JFU
1/27/2023
1/27/2023
CANCELED
LATH INSPECTION TO BE RECALLED.
2/2/2023 1:51 PM Jeff Rippee
Contact Name: Jeff Rippee
ROUGH PLBG
JAN
2/3/2023
2/3/2023
APPROVED
The Tradition Golf Club
Site Address: 78761 DEACON DR E
Phone:6199724545
e-Mail: jrippee@pacificviewestatesinc.com
2/2/2023 1:51 PM Jeff Rippee
Contact Name: Jeff Rippee
ROUGH MECH
JAN
2/3/2023
2/3/2023
APPROVED
The Tradition Golf Club
Site Address: 78761 DEACON DR E
Phone:6199724545
e-Mail: jrippee@pacificviewestatesinc.com
2/2/2023 1:51 PM Jeff Rippee
Contact Name: Jeff Rippee
ROUGH ELEC
JAN
2/3/2023
2/3/2023
APPROVED
The Tradition Golf Club
Site Address: 78761 DEACON DR E
Phone:6199724545
e-Mail: jrippee@pacificviewestatesinc.com
Printed: Tuesday, October 17, 2023 10:15:30 AM 11 of 22
WSYSiEMS
LATH
JAN
2/3/2023
2/3/2023
APPROVED
The Tradition Golf Club
2/2/2023 1:51 PM Jeff Rippee
Contact Name: Jeff Rippee
Site Address: 78761 DEACON DR E
Phone:6199724545
e-Mail: jrippee@pacificviewestatesinc.com
2/2/2023 1:51 PM Jeff Rippee
Contact Name: Jeff Rippee
Site Address: 78761 DEACON DR E
FRAMING
JAN
2/3/2023
2/3/2023
APPROVED
The Tradition Golf Club
Phone:6199724545
e-Mail: jrippee@pacificviewestatesinc.com
-PREVIOUS INSPECTION CORRECTIONS LIST
HAVE BEEN SATISFIED
2/9/2023 3:45 PM Jeff Rippee
Contact Name: Jeff Rippee
Site Address: 78761 DEACON DR E
Phone:6199724545
e-Mail: jrippee@pacificviewestatesinc.com
INSULATION
BLAK
2/10/2023
2/10/2023
PARTIALLY
eTRAKiT Inspection
Please provide site address for
APPROVED
Request
property.Need poly foam at casita,master
bath various locations all exterior walls
bottom plate and exterior wall.Missing
insulation at pocket doors.OK to proceed but
do not cover up areas lacking poly foam and
insulation recall for final approval.Upload
energy report inspection paperwork to E
track it.
Printed: Tuesday, October 17, 2023 10:15:30 AM 12 of 22
WSYSiEMS
2/24/2023 3:15 PM Jeff Rippee
Contact Name: Jeff Rippee
Site Address: 78761 DEACON DR E
Phone:6199724545
e-Mail: jrippee@pacificviewestatesinc.com
DRYWALL NAIL
DCL
2/27/2023
2/27/2023
DISAPPROVE
eTRAKiT Inspection
- DRYWALL NAIL APPROVABLE; HOWEVER,
D
Request
ONLY PARTIAL INSULATION APPROVAL WAS
GIVEN FOR THE DWELLING PER INSULATION
COMMENTS ON 2/10/2023.- PLEASE
CONTACT INSPECTOR BILL LAKES AT 760-777
-7000 TO RESOLVE PARTIAL INSULATION
APPROVAL.- UPLOAD QII LETTER TO E-
TRAKIT ATTACHMENTS FOR THIS PROJECT. -
NO APPROVAL TO CONTINUE AT THIS TIME.
2/27/2023 3:44 PM Jeff Rippee
Contact Name: Jeff Rippee
INSULATION
JAN
2/28/2023
2/28/2023
CANCELED
eTRAKiT Inspection
Site Address: 78761 DEACON DR E
Request
Phone:6199724545
e-Mail: jrippee@pacificviewestatesinc.com
3/1/2023 3:45 PM Jeff Rippee
Contact Name: Jeff Rippee
Site Address: 78761 DEACON DR E
Phone:6199724545
e-Mail: jrippee@pacificviewestatesinc.com
INSULATION
BLAK
3/2/2023
3/2/2023
DISAPPROVE
eTRAKiT Inspection
D
Request
Please provide site address for
property.Need poly foam at casita,master
bath various locations all exterior walls
bottom plate and exterior wall.OK to
proceed but do not cover up areas lacking
poly foam and insulation recall for final
approval.
Printed: Tuesday, October 17, 2023 10:15:30 AM 13 of 22
RWSYSiEMS
3/1/2023 3:29 PM Jeff Rippee
Contact Name: Jeff Rippee
SHOWER PAN
BLAK
3/2/2023
3/2/2023
APPROVED
eTRAKiT Inspection
Site Address: 78761 DEACON DR E
Request
Phone:6199724545
e-Mail: jrippee@pacificviewestatesinc.com
3/3/2023 3:49 PM Jeff Rippee
Contact Name: Jeff Rippee
Site Address: 78761 DEACON DR E
INSULATION
JAN
3/6/2023
3/6/2023
APPROVED
eTRAKiT Inspection
Phone:6199724545
Request
a -Mail: jrippee@pacificviewestatesinc.com
Areas verify based on previous insulation
inspection
3/3/2023 3:49 PM Jeff Rippee
Contact Name: Jeff Rippee
PARTIALLY
eTRAKiT Inspection
Site Address: 78761 DEACON DR E
DRYWALL NAIL
JAN
3/6/2023
3/7/2023
APPROVED
Request
Phone:6199724545
e-Mail: jrippee@pacificviewestatesinc.com
-PENDING HALLWAY POWDER BATHROOM
3/8/2023 3:49 PM Jeff Rippee
Contact Name: Jeff Rippee
DRYWALL NAIL
JAN
3/9/2023
3/9/2023
APPROVED
eTRAKiT Inspection
Site Address: 78761 DEACON DR E
Request
Phone:6199724545
e-Mail: jrippee@pacificviewestatesinc.com
TEMP USE OF PERM PWR
RHAR
5/10/2023
5/10/2023
APPROVED
FRAMING
BLD
5/12/2023
5/12/2023
CANCELED
- PREVIOUSLY APPROVED.
ROUGH ELEC
BLD
5/12/2023
5/12/2023
CANCELED
- PREVIOUSLY APPROVED.
Printed: Tuesday, October 17, 2023 10:15:30 AM 14 of 22
RWSYSiEMS
ROUGH MECH
BLD
5/12/2023
5/12/2023
CANCELED
- PREVIOUSLY APPROVED.
ROUGH PLBG
BLD
5/12/2023
5/12/2023
CANCELED
- PREVIOUSLY APPROVED.
GAS LINE/TEST
RHAR
5/12/2023
5/12/2023
APPROVED
OBTAINED FIRE DEPARTMENT APPROVAL
FINAL"
JAN
6/23/2023
6/28/2023
NOT READY
AND SOLAR FINAL PRIOR TO A FINAL
INSPECTION REQUEST
FINAL INSPECTION
LRO
6/29/2023
6/29/2023
APPROVED
-ANTI SIPHON VALVES REQUIRED. AT
EXTERIOR HOSE BIBS -All 120-volt, single
phase, 15- and 20-ampere branch circuits
supplying outlets or devices installed in
dwelling unit kitchens, family rooms, dining
rooms, living rooms, parlors, libraries, dens,
bedrooms, sunrooms, recreation rooms,
closets, hallways, laundry areas or similar
rooms or areas shall be protected by an
listed arc -fault circuit interrupter,
combination type, installed to provide
protection of the branch circuit or by any of
the other means described in 210.12(A)(2)
through (6)." (CEC ?210.12(A))-GFCI
FINAL"
JAN
7/21/2023
7/21/2023
DISAPPROVE
REQUIRED AT RECEPTACLE SERVING
D
GARAGE-6AWG CONDUCTOR UNDER SIZE
FOR A 100amp OCPD at main service -
PROVIDE 2" CLEARANCE FROM FLAT WORK
TO WEEP SCREED. Weep screed shall have a
minimum clearance of 4 inches above the
earth or 2 inches above paved areas -SECURE
CONDENSER TO CONCRETE PADS -
MECHANICAL ROOM PROVIDE VACANCY
SENSOR -PROVIDE SEDIMENT TRAP AT
WATER HEATER -AIR GAP REQUIRED FOR THE
DISHWASHER -PROVIDE VACANCY SENSOR
AT LAUNDRY ROOM,PANTRY AND
BATHROOMS-GFCI AT WET BAR NOT
FUNCTIONING AT TIME OF INSPECTION
Printed: Tuesday, October 17, 2023 10:15:30 AM 15 of 22
RWSYSiEMS
FINAL" JAN 7/25/2023 7/26/2023 APPROVED
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
RETURNED
REVIEWS
STATUS
REMARKS
NOTES
DATE
1ST BLDG
INTERWEST
11/30/2021
12/14/2021
12/15/2021
REVISIONS REQUIRED
COMPLETE (2 WK)
1ST BLDG NS (3 WK)
JAKE FUSON
11/30/2021
12/21/2021
1/27/2022
REVISIONS REQUIRED
SEE ATTACHED 1ST REVIEW CORRECTION LIST.
1ST FIRE (1 WK)
11/30/2021
12/7/2021
12/13/2021
APPROVED
IN
HEOHL
TRICENTS
ATTAOA
1ST PLANNING (1
CARLOS
11/30/2021
12/7/2021
12/7/2021
READY FOR APPROVAL
WK)
FLORES
PLEASE SUBMIT GREEN SHEET FOR DUST
1ST PUBLIC WORKS
AMY YU
11/30/2021
12/7/2021
12/8/2021
REVISIONS REQUIRED
CONTROL.
(1 WK)
NO COMMENT ON PGP.
1ST PERMIT TECH —
PERMIT TECH
11/30/2021
12/1/2021
11/30/2021
COMPLETE
ETRAKIT (1 DAY)
BUCKET
2ND BLDG
INTERWEST
3/1/2022
3/8/2022
3/9/2022
REVISIONS REQUIRED
COMPLETE (1 WK)
2ND BLDG NS —
JAKE FUSON
3/1/2022
3/8/2022
4/12/2022
APPROVED-
FOUNDATION PLAN REVIEW LETTER REQUIRED IN
ETRAKIT (1 WK)
CONDITIONS
ORDER TO SATISFY STRUCTURAL CORRECTIONS.
2ND PW GREEN
AMY YU
4/11/2022
4/18/2022
4/11/2022
READY FOR APPROVAL
SHEET
1ST BLDG NS-
JAKEFUSON
9/21/2022
9/22/2022
9/22/2022
APPROVED
DEFERRED TRUSS
ETRAKIT (1 DAY)
Printed: Tuesday, October 17, 2023 10:15:30 AM 16 of 22
WSYSiEMS
1. ENERGY DOCUMENTS MUST BE REGISTERED
2. REMOVE CREDIT FOR NON-STANDARD DUCT
LOCATION OR REVISE PLANS
3. THE INSULATION R-VALUES AND LOCATIONS
1ST BLDG NS -
JAKE FUSON
5/10/2023
5/17/2023
5/23/2023
REVISIONS REQUIRED
REVISION 1 - ENERGY
HAVE CHANGED IN THE REPORT BUT NO PLANS
ETRAKIT (1 WK)
DOCUMENTS
HAVE BEEN PROVIDED SHOWING THE CHANGES.
EITHER REMOVE THESE CHANGES FROM THE
ENERGY REPORT OR PROVIDE REVISED PLANS
FOR REVIEW.
-ENERGY DOCUMENTS MUST BE REGSITERED
-INSULATION IS PROPOSED TO BE CHANGED AS
PART OF THIS REVISION HOWEVER THE
INSULATION INSPECTION HAS ALREADY BEEN
COMPLETED. AN ADDITIONAL INSULATION
INSPECTION WILL BE REQUIRED TO VERIFY AIR -
1ST BLDG NS -
REVISION 1 - ENERGY
IMPERMEABLE (I.E. CLOSE -CELL SPRAY FOAM,
SAKE FUSON
6/12/2023
6/19/2023
7/17/2023
REVISIONS REQUIRED
ETRAKIT (1 WK)
DOCUMENTS
ETC) HAS BEEN INSTALLED AT THE ROOF DECK
PER ENERGY CALCULATIONS, THUS ALLOWING
THE CREDIT FOR NON-STANDARD DUCT
LOCATION
-ALL HERS VERIFICATION DOCUMENTATION WILL
NEED TO BE RE -REGISTERED AFTER THE NEW
REPORT IS REGISTERED
3RD BLDG NS —
JAKE FUSON
7/20/2023
7/21/2023
7/20/2023
APPROVED
REVISION 1
REVISION 1 - SOLAR PV SYSTEM UPDATES +
ETRAKIT (1 DAY)
BUILDING ENVELOPE INSULATION CHANGE.
BOND INFORMATION
Attachment Type
CREATED
OWNER
ATTACHMENTS
DESCRIPTION PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
4/14/2022
AARON HICKSON
SCHOOL FEE RECEIPT
2128_001.pdf
0
Rippee Residence
DOC
11/30/2021
Etrakit Contractor
1ST SUBMITTAL PLANS
Submittal
1
Set 11.23.2021(1).pdf
DOC
11/30/2021
Etrakit Contractor
1ST SUBMITTAL SOLAR
Rippee residence -Solar
1
PLANS
Plans(1).pdf
Printed: Tuesday, October 17, 2023 10:15:30 AM 17 of 22
WSYSiEMS
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
21-10-689 78761
DOC
11/30/2021
Etrakit Contractor
1ST SUBMITTAL SOILS
Deacon Dr. East
1
REPORT
Update.pdf
1ST SUBMITTAL
706_struct calcs
DOC
11/30/2021
Etrakit Contractor
STRUCTURAL
1
Ri ie. df
pp p
CALCULATIONS
DOC
11/30/2021
Etrakit Contractor
1ST SUBMITTAL ENERGY
T 24 Calcs.pdf
1
DOC
11/30/2021
Etrakit Contractor
1ST SUBMITTAL Cal
cheers certified 11-17-
1
Certs
21.pdf
Rippee 1_2nd BD
DOC
3/1/2022
Etrakit Contractor
2ND SUBMITTAL -
_Delta
Submittal_02.22.2022_F
1
PLANS
ull Set_Signed.pdf
2ND SUBMITTAL -
Rippee residence-
DOC
3/1/2022
Etrakit Contractor
SOLAR PLANS (FOR
Revised Solar Plans
1
REFERENCE ONLY)
wStamp.pdf
2ND SUBMITTAL - PV
Rippee residence -
DOC
3/1/2022
Etrakit Contractor
RESPONSES (FOR
Response to
1
REFERENCE ONLY)
comments.pdf
2ND SUBMITTAL - PV
DOC
3/1/2022
Etrakit Contractor
SOLAR STRUCTURAL
Rippee PV Calcs
1
RESPONSES (FOR
wStamp.pdf
REFERENCE ONLY)
2ND SUBMITTAL -
Rippee Arch. Plan Check
DOC
3/1/2022
Etrakit Contractor
ARCHITECTURAL
1
Response.pdf
RESPONSES
2ND SUBMITTAL -
REPORT OF
Grading Report July 30,
DOC
3/1/2022
Etrakit Contractor
OBSERVATIONS AND
1
1997.pdf
TESTING DURING
ROUGH GRADING
Printed: Tuesday, October 17, 2023 10:15:30 AM 18 of 22
WSYSiEMS
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
2ND SUBMITTAL -
DOC
3/1/2022
Etrakit Contractor
GEOTECHNICAL UPDATE
Tradition Update Letter
1
(12/12/1996)
Dec 12, 1996.pdf
2ND SUBMITTAL -
DOC
3/1/2022
Etrakit Contractor
GEOTECHNICAL UPDATE
Tradition Update Letter
1
July 31. 1997.pdf
(7/31/1997)
DOC
3/1/2022
Etrakit Contractor
2ND SUBMITTAL - ESR-
ESR-2316.pdf
1
2316
2ND SUBMITTAL -
DOC
3/1/2022
Etrakit Contractor
STRUCTURAL
706_struct calcs Rippie
1
(2).pdf
CALCULATIONS
2ND SUBMITTAL -
DOC
3/1/2022
Etrakit Contractor
STRUCTURAL
706_pccl.pdf
1
RESPONSES
Burrtec Construction
DOC
4/11/2022
Etrakit Contractor
WASTE MANAGEMENT
Debris Management
1
PLAN
Plan.pdf
DOC
4/11/2022
Etrakit Contractor
PM 10 GREEN SHEET
PM 10 Green Sheet.pdf
1
DOC
9/21/2022
Etrakit Contractor
706_trussl_cert_.pdf
1
DOC
7/6/2023
Etrakit Contractor
SUBCONTRACTOR LIST
SUB -CONTRACTORS LIST
1
FILLABLE.pdf
REVISION 1 - 3RD
78-761 Deacon Drive
DOC
7/20/2023
Etrakit Contractor
SUBMITTAL ENERGY
East - All Documents
1
DOCUMENTS
(3).pdf
DOC
1/6/2023
ELIZABETH MOLINA
SUBCONTRACTOR LIST
BRES2021-0834 SUB
0
LIST.pdf
STRUCTURAL
DOC
2/2/2023
Etrakit Public
OBSERVATION REPORT
Deacon Inspection 2-2-
1
Registration
& SPECIAL INSPECTION
23.pdf
REPORTS
Printed: Tuesday, October 17, 2023 10:15:30 AM 19 of 22
WSYSiEMS
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
Etrakit Public
Deacon Pad
DOC
2/2/2023
FORM CERTIFICATION
1
Registration
Certification.pdf
DOC
2/27/2023
Etrakit Public
PRELIMINARY QII
Deacon Insulation
1
Registration
LETTER
Cert.pdf
DOC
6/12/2023
Etrakit Public
REVISION 1- 2ND
Tim Scott Title 24
1
Registration
SUBMITTAL SHEET A7.1
Revision 1.pdf
DOC
6/12/2023
Etrakit Public
REVISION 1 - 2ND
Tim Scott Title 24
1
Registration
SUBMITTAL SHEET A7.2
Revision 2.pdf
74588 78761 Deacon Dr
DOC
12/15/2021
INTERWEST
1ST REVIEW INTERWEST
E New Residential SFD
0
INVOICE
BRES2021-0834.pdf
La Quinta-BRES2021-
DOC
12/15/2021
INTERWEST
1ST REVIEW INTERWEST
0834-PC1-78761 Deacon
0
COMMENTS
Dr E.docx
La Quinta-BRES2021-
DOC
3/9/2022
INTERWEST
2ND REVIEW
0834-PC2-78761 Deacon
0
INTERWEST COMMENTS
Dr E.docx
76619 78761 DEACON
DOC
3/9/2022
INTERWEST
2ND REVIEW
DR E BRES2021-
0
INTERWEST INVOICE
0834.pdf
BRES2021-0834 - C of
DOC
7/26/2023
JULIO ANAYA
C of O
1
O.pdf
BRES2021-0834 - 1ST
DOC
1/27/2022
JAKE FUSON
1ST REVIEW COMPLETE
REVIEW COMPLETE
1
CORRECTION LIST
CORRECTION LIST.pdf
BRES2021-0834 -
DEFERRED TRUSS
DOC
4/12/2022
JAKE FUSON
SUBMITTAL REQUEST
DEFERRED TRUSS
1
(APPROVED)
SUBMITTAL REQUEST
(APPROVED).pdf
Printed: Tuesday, October 17, 2023 10:15:30 AM 20 of 22
WSYSiEMS
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
BRES2021-0834 -
DOC
4/12/2022
JAKE FUSON
GEOTECHNICAL UPDATE
GEOTECHNICAL UPDATE
1
(APPROVED)
(APPROVED).pdf
BRES2021-0834 -
STRUCTURAL
DOC
4/12/2022
JAKE FUSON
CALCULATIONS
STRUCTURAL
1
CALCULATIONS
(APPROVED)
(APPROVED).pdf
DOC
4/12/2022
JAKE FUSON
PLANS (APPROVED)
BRES2021-0834 - PLANS
1
(APPROVED).pdf
BRES2021-0834 -
FOUNDATION PLAN
DOC
4/13/2022
JAKE FUSON
REVIEW LETTER
FOUNDATION PLAN
1
(APPROVED)
REVIEW LETTER
(APPROVED).pdf
BRES2021-0834 -
DEFERRED TRUSS - 1ST
DOC
9/22/2022
JAKE FUSON
SUBMITTAL TRUSS
DEFERRED TRUSS - 1ST
1
SUBMITTAL TRUSS
CALCULATIONS
CALCULATIONS.pdf
BRES2021-0834 - TRUSS
DOC
9/22/2022
JAKE FUSON
TRUSS CALCULATIONS
CALCULATIONS
1
(APPROVED)
(APPROVED).pdf
BRES2021-0834 -
REVISION 1 - ENERGY
DOC
7/20/2023
JAKE FUSON
DOCUMENTS
REVISION 1- ENERGY
1
(APPROVED)
DOCUMENTS
(APPROVED).pdf
DOC
4/12/2022
JACK LIMA
GRANT DEED
Grant Deed.pdf
0
SUNROSE
DOC
12/13/2022
JACK LIMA
CORPORATION
3557 001.pdf
0
CONTRACTOR LETTER
—
RELEASE OF PERMIT
PACIFIC VIEW ESTATES
DOC
12/13/2022
JACK LIMA
ARTICLES OF
3558_001.pdf
0
INCORPORATION
Printed: Tuesday, October 17, 2023 10:15:30 AM 21 of 22
WSYSiEMS
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
12/13/2022
JACK LIMA
OWNER BUILDER
3559 001.pdf
0
DECLARATION
—
REVISION 1 - 1ST
ENERGY
(REVISION -.p
DOC
5/10/2023
JACK LIMA
SUBMITTAL ENERGY
1
T-24df
REPORT
BRES2021-0834 - FIRE
DOC
12/13/2021
KOHL HETRICK
FIRE CONDITIONS OF
CONDITIONS OF
1
APPROVAL
APPROVAL.pdf
2ND SUBMITTAL -
PHOTO
3/2/2022
Etrakit Contractor
DEFERRED TRUSS
IMG_1051(3).jpg
1
SUBMITTAL
APPLICATION
Printed: Tuesday, October 17, 2023 10:15:30 AM 22 of 22
WSYSiEMS
CITY OF LA QUINTA
JOB ADDRESS 78761 Deacon Dr E PERMIT NUMBER BRES2022-0834 OWNER Jeff Rippee
BUILDER Jeff Rippee
This form shall be posted on the job with the Building Inspection Card at all times in a conspicuous place. Only persons appearing on the list or their employees are
authorized to work on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoopage of work
and/or the voidance of building permmit. For each applicable trade, all information requested below must be completed by the applicant. "On File" is not an accepatble resonse.
TRADE/CLASSIFICATION
CONTRACTOR
STATE CONTRACTOR'S LICENSE
WORKER COMPENSATION INSURANCE
CITY BUSINESS LICENSE
Company Name
Classification
(e.g. A, e, c-a)
California
Li
License
Number
Exp. Date
Carrier Name
(e.g. State Fund, CalComp)
PolicyNumbers
(Format Varies)
Exp. Date
License Number
Exp. Date
EARTHWORK (C-12)
Sunrose Corporation
B
533670
/30/24
Accredited Surety
1AUICA160135569100
/7/24
0001137
CONCRETE (C-8)
Sunrose Corporation
B
533670
/30/24
Accredited Surety
IAUICA160135569100
2/7/24
0001137
FRAMING (C-5)
Sunrose Corporation
B
533670
/30/24
Accredited Surety
1AUICA160135569100
2/7/24
0001137
STRUCT. STEEL (C-51)
N/A
MASONRY (C-29)
Sunrose Corporation
B
533670
6/30/24
State Fund
1948056
1/23
0001137
PLUMBING (C-36)
Sunrose Corporation
B
533670
6/30/24
State Fund
1948056
1/23
0001137
LATH, PLASTER (C-35)
Pavilion Plastering
C-35
1062999
/29/24
Falls Lake Fire & Casualty
zLA017051
/1/23
DRYWALL(C-9)
H S Drywall
C-9
1009783
12/31/23
Falls Lake Fire & Casualty
FLA01671602
/24
HVAC (C-20)
Simmons Air
C-20
780534
0/31/23
American Contractors
DOEKS5192
/23
0003427
99/30/23
ELECTRICAL (C-10)
Rangel Electric
C-10
753548
/28/23
Accredited Surety
ATCA16001413
/23
0010823
9/30/23
ROOFING (C-39)
Eckland Roofing
C-39
715643
1/30/23
Continental Indemnity
168463770104
1/23
0001724
9/30/23
SHEET METAL (C-43)
N/A
FLOORING(C-16)
D & R Flooring Inc.
C-15
GLAZING(C-17)
JMI Windows
C-17
908971
5/31/24
Republic Indemnity
25604601
8/23
762612
3/31/23
INSULATION (C-2)
TruTeam
C-2
1034361
12/31/23
Old Republic
MWC31557122
6/23
765658
3/31/23
SEWAGE DISP. (C-42)
N/A
PAINTING (C-33)
Sunrose Corporation
B
533670
/30/24
Accredited Surety
1AUICA160135569100
2/7/24
0001137
CERAMIC TILE (C-54)
Sunrose Corporation
B
533670
/30/24
Accredited Surety
IAUICA160135569100
/7/24
0001137
CABINETS (C-6)
Custom Creations of the Desert
C-6
964505
/31/23
Clear Spring Property
WC01229400
10/23
770726
6/30/23
FENCING (C-13)
Sunrose Corporation
B
533670
/30/24
Accredited Surety
1AUICA160135569100
2/7/24
0001137
LANDSCAPING (C-27)
Sunrose Corporation
B
533670
6/30/24
Accredited Surety
1AUICA160135569100
2/7/24
0001137
POOL (C-53)
McIntyre Pools & Spas
C-53
614611
9/30/23
Accredited Surety & Casualty
1AUICA160129887400
7/5/23
SUNROSE CORPORATION
40-101 Monterey Ave #131.214
Rancho Mirage, CA 92270
760-702-0119
December 12, 2022
Ref: Permit No. BRES 2021-0834 Building Permit
Permit No. BPOL 2022-0354 Pool Permit
78761 Deacon Dr E
La Quinta Ca 922253
Jeff Rippee, President
Pacific View Estates Inc.
52700 Avenida Vallejo
La Quinta, Ca 92253
Dear Mr. Rippee,
hereby surrender, withdraw and release all my rights to the above referenced permits
to build a single family residence and pool located at 78761 Deacon Dr. E, La Quinta Ca
92253.1 also surrender, withdraw and release all my rights to the architectural,
landscape and engineering drawings attached to the permits.
Sincerely,
Michael Tuvell
President
Sunrose Corp.
Dated / 2 - it-7-7-
irippee@pacifrcviewestatesinc.com
From: Micheal Tuveff <michaeftuveII14@gmail.com>
Sent: Monday, December 12, 2022 6:08 PM
To: Jeff Rippee
Subject: RELEASE OF PERMIT LETTER
Attachments: RELEASE OF PERMIT LETTER pdf
Jeff here you go.
Michael Tuvell
President
SUNROSE CORPORATION
► 0-101 Monterey Ave. 5uite#B1-214
Rancho Mirage, CA 92270
Office: 442-324-2298
Cell: 760-702-0119
t(v Q 0 (V
GEM of the DESERT —
Certificate of Occupancy
Design and Development Department
This Certificate is issued pursuant to the requirements of Chapter 1 Section R110 of the
California Residential Code, certifying that, at the time of issuance, this structure was in
compliance with the provisions of the Building Code and the various ordinances of the City
regulating building construction and/or use.
BUILDING ADDRESS: 78761 DEACON DR E
Use classification: RESIDENTIAL - SINGLE FAMILY DWELLING
Occupancy Group: R-3 U
Code Edition: 2019
M
JULIO ANAYA
Date: 7/26/2023
Building Official: AJ ORTEGA
Type of Construction: VB
Sprinkler Installed: YES
Permit No.: BRES2021-0834
Land Use Zone: RL
Sprinkler Required: YES
Owner of Building: PACIFIC VIEW ESTATES INC
Address: 44451 GRAND CANYON LANE
City, ST, ZIP: PALM DESERT, CA 92260
POST IN A CONSPICUOUS PLACE